SLAC Magnetic Measurements Date: 07-21-2026 Time: 16:56:38 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16335 Dataset Number: 1 Run Purpose: Final Results Run Type: Run Number: 6 Measurement Device: Stretched Wire Operator: YL Comment: 16:56:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:48 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:56:49 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:56:51 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:56:52 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:57:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:57:35 Integrated Voltage Measurement... 16:57:44 Voltage Offset Correction: v_off_ini = 3055.877 uV, v_off_fin = 3055.489 uV 16:57:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -128.792 uVs 16:57:44 Integrated Voltage Measurement... 16:57:53 Voltage Offset Correction: v_off_ini = 3044.829 uV, v_off_fin = 3045.137 uV 16:57:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.776 uVs 16:57:53 Integrated Voltage Measurement... 16:58:02 Voltage Offset Correction: v_off_ini = 3047.423 uV, v_off_fin = 3036.100 uV 16:58:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.677 uVs 16:58:02 Integrated Voltage Measurement... 16:58:11 Voltage Offset Correction: v_off_ini = 3034.711 uV, v_off_fin = 3048.249 uV 16:58:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 169.115 uVs 16:58:11 Integrated Voltage Measurement... 16:58:20 Voltage Offset Correction: v_off_ini = 3044.673 uV, v_off_fin = 3044.322 uV 16:58:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.262 uVs 16:58:20 Integrated Voltage Measurement... 16:58:29 Voltage Offset Correction: v_off_ini = 3045.816 uV, v_off_fin = 3048.296 uV 16:58:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.193 uVs 16:58:34 I1X Average and RMS of Measurements VT = -144.636 +- 12.231 uVs I1X = 28.929 +- 2.445 uTm 16:58:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:58:40 Integrated Voltage Measurement... 16:58:49 Voltage Offset Correction: v_off_ini = 3057.065 uV, v_off_fin = 3028.580 uV 16:58:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.573 uVs 16:58:49 Integrated Voltage Measurement... 16:58:58 Voltage Offset Correction: v_off_ini = 3035.346 uV, v_off_fin = 3075.680 uV 16:58:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.763 uVs 16:58:58 Integrated Voltage Measurement... 16:59:07 Voltage Offset Correction: v_off_ini = 3034.076 uV, v_off_fin = 3039.379 uV 16:59:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.576 uVs 16:59:07 Integrated Voltage Measurement... 16:59:16 Voltage Offset Correction: v_off_ini = 3069.808 uV, v_off_fin = 3083.836 uV 16:59:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.509 uVs 16:59:16 Integrated Voltage Measurement... 16:59:25 Voltage Offset Correction: v_off_ini = 3071.875 uV, v_off_fin = 3050.209 uV 16:59:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -211.209 uVs 16:59:25 Integrated Voltage Measurement... 16:59:34 Voltage Offset Correction: v_off_ini = 3044.815 uV, v_off_fin = 3075.200 uV 16:59:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.146 uVs 16:59:38 I1Y Average and RMS of Measurements VT = -215.629 +- 5.008 uVs I1Y = -43.127 +- 1.002 uTm 16:59:43 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:59:46 Integrated Voltage Measurement... 16:59:55 Voltage Offset Correction: v_off_ini = 3081.949 uV, v_off_fin = 3084.826 uV 16:59:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -99.530 uVs 16:59:55 Integrated Voltage Measurement... 17:00:04 Voltage Offset Correction: v_off_ini = 3073.674 uV, v_off_fin = 3083.475 uV 17:00:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.415 uVs 17:00:04 Integrated Voltage Measurement... 17:00:13 Voltage Offset Correction: v_off_ini = 3063.527 uV, v_off_fin = 3079.564 uV 17:00:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.594 uVs 17:00:13 Integrated Voltage Measurement... 17:00:22 Voltage Offset Correction: v_off_ini = 3103.103 uV, v_off_fin = 3111.480 uV 17:00:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.477 uVs 17:00:22 Integrated Voltage Measurement... 17:00:31 Voltage Offset Correction: v_off_ini = 3108.237 uV, v_off_fin = 3075.890 uV 17:00:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.590 uVs 17:00:31 Integrated Voltage Measurement... 17:00:40 Voltage Offset Correction: v_off_ini = 3119.566 uV, v_off_fin = 3116.463 uV 17:00:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.080 uVs 17:00:43 I2X Average and RMS of Measurements VT = -106.781 +- 8.371 uVs I2X = 9.824 +- 0.770 uTm^2 17:00:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:00:50 Integrated Voltage Measurement... 17:00:59 Voltage Offset Correction: v_off_ini = 3087.922 uV, v_off_fin = 3096.874 uV 17:00:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.211 uVs 17:00:59 Integrated Voltage Measurement... 17:01:08 Voltage Offset Correction: v_off_ini = 3093.812 uV, v_off_fin = 3113.482 uV 17:01:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.571 uVs 17:01:08 Integrated Voltage Measurement... 17:01:17 Voltage Offset Correction: v_off_ini = 3103.209 uV, v_off_fin = 3098.945 uV 17:01:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.892 uVs 17:01:17 Integrated Voltage Measurement... 17:01:26 Voltage Offset Correction: v_off_ini = 3118.625 uV, v_off_fin = 3097.833 uV 17:01:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.558 uVs 17:01:26 Integrated Voltage Measurement... 17:01:35 Voltage Offset Correction: v_off_ini = 3106.162 uV, v_off_fin = 3088.654 uV 17:01:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.347 uVs 17:01:35 Integrated Voltage Measurement... 17:01:44 Voltage Offset Correction: v_off_ini = 3088.980 uV, v_off_fin = 3087.060 uV 17:01:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.286 uVs 17:01:47 I2Y Average and RMS of Measurements VT = -215.978 +- 14.452 uVs I2Y = -19.870 +- 1.330 uTm^2 17:01:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:01:56 Integrated Voltage Measurement... 17:02:05 Voltage Offset Correction: v_off_ini = 3084.935 uV, v_off_fin = 3083.469 uV 17:02:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.032 uVs 17:02:05 Integrated Voltage Measurement... 17:02:14 Voltage Offset Correction: v_off_ini = 3081.124 uV, v_off_fin = 3068.179 uV 17:02:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.766 uVs 17:02:14 Integrated Voltage Measurement... 17:02:23 Voltage Offset Correction: v_off_ini = 3071.124 uV, v_off_fin = 3067.309 uV 17:02:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.435 uVs 17:02:23 Integrated Voltage Measurement... 17:02:32 Voltage Offset Correction: v_off_ini = 3083.393 uV, v_off_fin = 3108.146 uV 17:02:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.739 uVs 17:02:32 Integrated Voltage Measurement... 17:02:41 Voltage Offset Correction: v_off_ini = 3066.274 uV, v_off_fin = 3069.496 uV 17:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.003 uVs 17:02:41 Integrated Voltage Measurement... 17:02:50 Voltage Offset Correction: v_off_ini = 3102.403 uV, v_off_fin = 3086.564 uV 17:02:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.391 uVs 17:02:54 I1X Average and RMS of Measurements VT = -119.894 +- 12.428 uVs I1X = 23.979 +- 2.486 uTm 17:02:56 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:03:00 Integrated Voltage Measurement... 17:03:09 Voltage Offset Correction: v_off_ini = 3069.979 uV, v_off_fin = 3070.579 uV 17:03:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.212 uVs 17:03:09 Integrated Voltage Measurement... 17:03:18 Voltage Offset Correction: v_off_ini = 3078.435 uV, v_off_fin = 3093.597 uV 17:03:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.978 uVs 17:03:18 Integrated Voltage Measurement... 17:03:27 Voltage Offset Correction: v_off_ini = 3095.502 uV, v_off_fin = 3077.929 uV 17:03:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.597 uVs 17:03:27 Integrated Voltage Measurement... 17:03:36 Voltage Offset Correction: v_off_ini = 3086.483 uV, v_off_fin = 3097.289 uV 17:03:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.273 uVs 17:03:36 Integrated Voltage Measurement... 17:03:45 Voltage Offset Correction: v_off_ini = 3080.538 uV, v_off_fin = 3056.636 uV 17:03:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.847 uVs 17:03:45 Integrated Voltage Measurement... 17:03:54 Voltage Offset Correction: v_off_ini = 3058.419 uV, v_off_fin = 3071.204 uV 17:03:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.186 uVs 17:03:58 I1Y Average and RMS of Measurements VT = -224.849 +- 6.893 uVs I1Y = -44.970 +- 1.379 uTm 17:04:04 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:04:06 Integrated Voltage Measurement... 17:04:15 Voltage Offset Correction: v_off_ini = 3072.697 uV, v_off_fin = 3071.830 uV 17:04:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -83.918 uVs 17:04:15 Integrated Voltage Measurement... 17:04:24 Voltage Offset Correction: v_off_ini = 3054.700 uV, v_off_fin = 3092.840 uV 17:04:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.956 uVs 17:04:24 Integrated Voltage Measurement... 17:04:33 Voltage Offset Correction: v_off_ini = 3095.520 uV, v_off_fin = 3091.751 uV 17:04:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.537 uVs 17:04:33 Integrated Voltage Measurement... 17:04:42 Voltage Offset Correction: v_off_ini = 3085.230 uV, v_off_fin = 3110.943 uV 17:04:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 69.837 uVs 17:04:42 Integrated Voltage Measurement... 17:04:51 Voltage Offset Correction: v_off_ini = 3101.093 uV, v_off_fin = 3101.063 uV 17:04:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.466 uVs 17:04:51 Integrated Voltage Measurement... 17:05:00 Voltage Offset Correction: v_off_ini = 3088.567 uV, v_off_fin = 3099.286 uV 17:05:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.568 uVs 17:05:03 I2X Average and RMS of Measurements VT = -81.380 +- 3.132 uVs I2X = 7.487 +- 0.288 uTm^2 17:05:08 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:05:10 Integrated Voltage Measurement... 17:05:19 Voltage Offset Correction: v_off_ini = 3067.856 uV, v_off_fin = 3044.000 uV 17:05:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.897 uVs 17:05:19 Integrated Voltage Measurement... 17:05:28 Voltage Offset Correction: v_off_ini = 3080.994 uV, v_off_fin = 3101.834 uV 17:05:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.621 uVs 17:05:28 Integrated Voltage Measurement... 17:05:37 Voltage Offset Correction: v_off_ini = 3114.364 uV, v_off_fin = 3098.934 uV 17:05:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -226.389 uVs 17:05:37 Integrated Voltage Measurement... 17:05:46 Voltage Offset Correction: v_off_ini = 3092.352 uV, v_off_fin = 3062.384 uV 17:05:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.085 uVs 17:05:46 Integrated Voltage Measurement... 17:05:55 Voltage Offset Correction: v_off_ini = 3099.867 uV, v_off_fin = 3114.525 uV 17:05:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.904 uVs 17:05:55 Integrated Voltage Measurement... 17:06:04 Voltage Offset Correction: v_off_ini = 3094.469 uV, v_off_fin = 3092.972 uV 17:06:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.922 uVs 17:06:07 I2Y Average and RMS of Measurements VT = -235.970 +- 5.282 uVs I2Y = -21.710 +- 0.486 uTm^2 17:06:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:06:16 Integrated Voltage Measurement... 17:06:24 Voltage Offset Correction: v_off_ini = 3081.881 uV, v_off_fin = 3062.873 uV 17:06:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -138.927 uVs 17:06:25 Integrated Voltage Measurement... 17:06:33 Voltage Offset Correction: v_off_ini = 3057.983 uV, v_off_fin = 3073.723 uV 17:06:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.571 uVs 17:06:34 Integrated Voltage Measurement... 17:06:42 Voltage Offset Correction: v_off_ini = 3059.082 uV, v_off_fin = 3033.762 uV 17:06:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.587 uVs 17:06:42 Integrated Voltage Measurement... 17:06:51 Voltage Offset Correction: v_off_ini = 3038.074 uV, v_off_fin = 3030.718 uV 17:06:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.364 uVs 17:06:51 Integrated Voltage Measurement... 17:07:00 Voltage Offset Correction: v_off_ini = 3062.569 uV, v_off_fin = 3050.694 uV 17:07:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -167.956 uVs 17:07:00 Integrated Voltage Measurement... 17:07:09 Voltage Offset Correction: v_off_ini = 3035.934 uV, v_off_fin = 3021.961 uV 17:07:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.710 uVs 17:07:14 I1X Average and RMS of Measurements VT = -143.686 +- 6.645 uVs I1X = 28.739 +- 1.331 uTm 17:07:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:07:20 Integrated Voltage Measurement... 17:07:29 Voltage Offset Correction: v_off_ini = 3036.744 uV, v_off_fin = 3000.565 uV 17:07:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -243.469 uVs 17:07:29 Integrated Voltage Measurement... 17:07:38 Voltage Offset Correction: v_off_ini = 3001.413 uV, v_off_fin = 3017.266 uV 17:07:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.117 uVs 17:07:38 Integrated Voltage Measurement... 17:07:47 Voltage Offset Correction: v_off_ini = 3008.349 uV, v_off_fin = 2980.792 uV 17:07:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.208 uVs 17:07:47 Integrated Voltage Measurement... 17:07:56 Voltage Offset Correction: v_off_ini = 3003.226 uV, v_off_fin = 3014.971 uV 17:07:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.442 uVs 17:07:56 Integrated Voltage Measurement... 17:08:05 Voltage Offset Correction: v_off_ini = 3017.365 uV, v_off_fin = 3009.643 uV 17:08:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.815 uVs 17:08:05 Integrated Voltage Measurement... 17:08:14 Voltage Offset Correction: v_off_ini = 2996.595 uV, v_off_fin = 3032.332 uV 17:08:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.383 uVs 17:08:18 I1Y Average and RMS of Measurements VT = -244.739 +- 5.011 uVs I1Y = -48.949 +- 1.002 uTm 17:08:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:08:26 Integrated Voltage Measurement... 17:08:35 Voltage Offset Correction: v_off_ini = 3006.503 uV, v_off_fin = 3002.546 uV 17:08:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -105.589 uVs 17:08:35 Integrated Voltage Measurement... 17:08:44 Voltage Offset Correction: v_off_ini = 3033.062 uV, v_off_fin = 3031.400 uV 17:08:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.860 uVs 17:08:44 Integrated Voltage Measurement... 17:08:53 Voltage Offset Correction: v_off_ini = 3031.604 uV, v_off_fin = 3011.480 uV 17:08:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.691 uVs 17:08:53 Integrated Voltage Measurement... 17:09:02 Voltage Offset Correction: v_off_ini = 3007.943 uV, v_off_fin = 3035.155 uV 17:09:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.480 uVs 17:09:02 Integrated Voltage Measurement... 17:09:11 Voltage Offset Correction: v_off_ini = 3029.510 uV, v_off_fin = 3028.813 uV 17:09:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.844 uVs 17:09:11 Integrated Voltage Measurement... 17:09:20 Voltage Offset Correction: v_off_ini = 3022.827 uV, v_off_fin = 2999.675 uV 17:09:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.240 uVs 17:09:22 I2X Average and RMS of Measurements VT = -107.451 +- 7.995 uVs I2X = 9.886 +- 0.736 uTm^2 17:09:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:09:30 Integrated Voltage Measurement... 17:09:39 Voltage Offset Correction: v_off_ini = 2995.408 uV, v_off_fin = 2977.217 uV 17:09:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.421 uVs 17:09:39 Integrated Voltage Measurement... 17:09:48 Voltage Offset Correction: v_off_ini = 2998.036 uV, v_off_fin = 2986.173 uV 17:09:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.058 uVs 17:09:48 Integrated Voltage Measurement... 17:09:57 Voltage Offset Correction: v_off_ini = 2983.788 uV, v_off_fin = 2998.185 uV 17:09:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.255 uVs 17:09:57 Integrated Voltage Measurement... 17:10:06 Voltage Offset Correction: v_off_ini = 2978.900 uV, v_off_fin = 2963.243 uV 17:10:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.867 uVs 17:10:06 Integrated Voltage Measurement... 17:10:15 Voltage Offset Correction: v_off_ini = 2984.395 uV, v_off_fin = 2986.203 uV 17:10:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.764 uVs 17:10:15 Integrated Voltage Measurement... 17:10:24 Voltage Offset Correction: v_off_ini = 2946.410 uV, v_off_fin = 2942.334 uV 17:10:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.925 uVs 17:10:27 I2Y Average and RMS of Measurements VT = -262.048 +- 10.357 uVs I2Y = -24.108 +- 0.953 uTm^2 17:10:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:10:35 Integrated Voltage Measurement... 17:10:44 Voltage Offset Correction: v_off_ini = 3003.813 uV, v_off_fin = 2989.063 uV 17:10:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.755 uVs 17:10:44 Integrated Voltage Measurement... 17:10:53 Voltage Offset Correction: v_off_ini = 2986.489 uV, v_off_fin = 2978.396 uV 17:10:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.002 uVs 17:10:53 Integrated Voltage Measurement... 17:11:02 Voltage Offset Correction: v_off_ini = 2967.869 uV, v_off_fin = 2974.727 uV 17:11:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.525 uVs 17:11:02 Integrated Voltage Measurement... 17:11:11 Voltage Offset Correction: v_off_ini = 2987.088 uV, v_off_fin = 2990.264 uV 17:11:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.603 uVs 17:11:11 Integrated Voltage Measurement... 17:11:20 Voltage Offset Correction: v_off_ini = 2978.386 uV, v_off_fin = 2986.450 uV 17:11:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.946 uVs 17:11:20 Integrated Voltage Measurement... 17:11:29 Voltage Offset Correction: v_off_ini = 3004.582 uV, v_off_fin = 3005.172 uV 17:11:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.577 uVs 17:11:34 I1X Average and RMS of Measurements VT = -143.735 +- 10.902 uVs I1X = 28.747 +- 2.181 uTm 17:11:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:11:40 Integrated Voltage Measurement... 17:11:49 Voltage Offset Correction: v_off_ini = 2973.483 uV, v_off_fin = 2968.399 uV 17:11:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -254.362 uVs 17:11:49 Integrated Voltage Measurement... 17:11:58 Voltage Offset Correction: v_off_ini = 2981.199 uV, v_off_fin = 2990.371 uV 17:11:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.667 uVs 17:11:58 Integrated Voltage Measurement... 17:12:07 Voltage Offset Correction: v_off_ini = 3011.739 uV, v_off_fin = 2984.659 uV 17:12:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.109 uVs 17:12:07 Integrated Voltage Measurement... 17:12:16 Voltage Offset Correction: v_off_ini = 3009.581 uV, v_off_fin = 3009.068 uV 17:12:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.552 uVs 17:12:16 Integrated Voltage Measurement... 17:12:25 Voltage Offset Correction: v_off_ini = 2979.542 uV, v_off_fin = 2974.546 uV 17:12:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.304 uVs 17:12:25 Integrated Voltage Measurement... 17:12:34 Voltage Offset Correction: v_off_ini = 2999.097 uV, v_off_fin = 3009.799 uV 17:12:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.247 uVs 17:12:38 I1Y Average and RMS of Measurements VT = -254.207 +- 6.417 uVs I1Y = -50.842 +- 1.284 uTm 17:12:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:12:46 Integrated Voltage Measurement... 17:12:55 Voltage Offset Correction: v_off_ini = 3010.905 uV, v_off_fin = 2991.397 uV 17:12:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.423 uVs 17:12:55 Integrated Voltage Measurement... 17:13:04 Voltage Offset Correction: v_off_ini = 2977.052 uV, v_off_fin = 2985.162 uV 17:13:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.828 uVs 17:13:04 Integrated Voltage Measurement... 17:13:13 Voltage Offset Correction: v_off_ini = 2974.707 uV, v_off_fin = 2966.030 uV 17:13:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -122.307 uVs 17:13:13 Integrated Voltage Measurement... 17:13:22 Voltage Offset Correction: v_off_ini = 2974.771 uV, v_off_fin = 2983.200 uV 17:13:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 92.650 uVs 17:13:22 Integrated Voltage Measurement... 17:13:31 Voltage Offset Correction: v_off_ini = 2992.526 uV, v_off_fin = 2992.677 uV 17:13:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -125.982 uVs 17:13:31 Integrated Voltage Measurement... 17:13:40 Voltage Offset Correction: v_off_ini = 3001.300 uV, v_off_fin = 3010.041 uV 17:13:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.133 uVs 17:13:42 I2X Average and RMS of Measurements VT = -111.887 +- 7.213 uVs I2X = 10.295 +- 0.664 uTm^2 17:13:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:13:50 Integrated Voltage Measurement... 17:13:59 Voltage Offset Correction: v_off_ini = 2990.404 uV, v_off_fin = 3000.088 uV 17:13:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.644 uVs 17:13:59 Integrated Voltage Measurement... 17:14:08 Voltage Offset Correction: v_off_ini = 2979.808 uV, v_off_fin = 2980.496 uV 17:14:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.078 uVs 17:14:08 Integrated Voltage Measurement... 17:14:17 Voltage Offset Correction: v_off_ini = 3003.083 uV, v_off_fin = 3002.246 uV 17:14:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.650 uVs 17:14:17 Integrated Voltage Measurement... 17:14:26 Voltage Offset Correction: v_off_ini = 2992.780 uV, v_off_fin = 2983.330 uV 17:14:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.477 uVs 17:14:26 Integrated Voltage Measurement... 17:14:35 Voltage Offset Correction: v_off_ini = 2988.634 uV, v_off_fin = 3006.481 uV 17:14:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.095 uVs 17:14:35 Integrated Voltage Measurement... 17:14:44 Voltage Offset Correction: v_off_ini = 2976.890 uV, v_off_fin = 2983.750 uV 17:14:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.283 uVs 17:14:47 I2Y Average and RMS of Measurements VT = -274.538 +- 4.166 uVs I2Y = -25.257 +- 0.383 uTm^2 17:14:51 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:14:55 Integrated Voltage Measurement... 17:15:04 Voltage Offset Correction: v_off_ini = 2992.682 uV, v_off_fin = 2988.440 uV 17:15:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -190.160 uVs 17:15:04 Integrated Voltage Measurement... 17:15:13 Voltage Offset Correction: v_off_ini = 2969.449 uV, v_off_fin = 2970.607 uV 17:15:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 184.043 uVs 17:15:13 Integrated Voltage Measurement... 17:15:22 Voltage Offset Correction: v_off_ini = 2947.394 uV, v_off_fin = 2948.413 uV 17:15:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.829 uVs 17:15:22 Integrated Voltage Measurement... 17:15:31 Voltage Offset Correction: v_off_ini = 2972.329 uV, v_off_fin = 2985.041 uV 17:15:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.612 uVs 17:15:31 Integrated Voltage Measurement... 17:15:40 Voltage Offset Correction: v_off_ini = 2981.182 uV, v_off_fin = 2975.593 uV 17:15:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -199.270 uVs 17:15:40 Integrated Voltage Measurement... 17:15:49 Voltage Offset Correction: v_off_ini = 2987.893 uV, v_off_fin = 2976.803 uV 17:15:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 173.992 uVs 17:15:54 I1X Average and RMS of Measurements VT = -176.651 +- 14.448 uVs I1X = 35.330 +- 2.890 uTm 17:15:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:16:00 Integrated Voltage Measurement... 17:16:09 Voltage Offset Correction: v_off_ini = 2966.130 uV, v_off_fin = 2956.096 uV 17:16:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.164 uVs 17:16:09 Integrated Voltage Measurement... 17:16:18 Voltage Offset Correction: v_off_ini = 2963.384 uV, v_off_fin = 2954.898 uV 17:16:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 286.603 uVs 17:16:18 Integrated Voltage Measurement... 17:16:27 Voltage Offset Correction: v_off_ini = 2990.395 uV, v_off_fin = 2993.338 uV 17:16:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.174 uVs 17:16:27 Integrated Voltage Measurement... 17:16:36 Voltage Offset Correction: v_off_ini = 2988.612 uV, v_off_fin = 2997.923 uV 17:16:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.906 uVs 17:16:36 Integrated Voltage Measurement... 17:16:45 Voltage Offset Correction: v_off_ini = 2997.104 uV, v_off_fin = 2980.672 uV 17:16:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.940 uVs 17:16:45 Integrated Voltage Measurement... 17:16:54 Voltage Offset Correction: v_off_ini = 3019.871 uV, v_off_fin = 3012.133 uV 17:16:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.504 uVs 17:16:58 I1Y Average and RMS of Measurements VT = -270.715 +- 7.310 uVs I1Y = -54.143 +- 1.462 uTm 17:17:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:17:06 Integrated Voltage Measurement... 17:17:15 Voltage Offset Correction: v_off_ini = 3006.912 uV, v_off_fin = 2995.660 uV 17:17:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -104.091 uVs 17:17:15 Integrated Voltage Measurement... 17:17:24 Voltage Offset Correction: v_off_ini = 3018.052 uV, v_off_fin = 3041.391 uV 17:17:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.761 uVs 17:17:24 Integrated Voltage Measurement... 17:17:33 Voltage Offset Correction: v_off_ini = 3015.179 uV, v_off_fin = 3005.472 uV 17:17:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.133 uVs 17:17:33 Integrated Voltage Measurement... 17:17:42 Voltage Offset Correction: v_off_ini = 2997.768 uV, v_off_fin = 3007.606 uV 17:17:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.424 uVs 17:17:42 Integrated Voltage Measurement... 17:17:51 Voltage Offset Correction: v_off_ini = 2965.734 uV, v_off_fin = 2955.112 uV 17:17:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.428 uVs 17:17:51 Integrated Voltage Measurement... 17:18:00 Voltage Offset Correction: v_off_ini = 2981.681 uV, v_off_fin = 2978.492 uV 17:18:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.165 uVs 17:18:03 I2X Average and RMS of Measurements VT = -111.001 +- 7.756 uVs I2X = 10.212 +- 0.713 uTm^2 17:18:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:18:10 Integrated Voltage Measurement... 17:18:19 Voltage Offset Correction: v_off_ini = 2983.819 uV, v_off_fin = 2978.363 uV 17:18:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.646 uVs 17:18:19 Integrated Voltage Measurement... 17:18:28 Voltage Offset Correction: v_off_ini = 2992.846 uV, v_off_fin = 2982.730 uV 17:18:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.367 uVs 17:18:28 Integrated Voltage Measurement... 17:18:37 Voltage Offset Correction: v_off_ini = 2986.157 uV, v_off_fin = 2982.977 uV 17:18:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.200 uVs 17:18:37 Integrated Voltage Measurement... 17:18:46 Voltage Offset Correction: v_off_ini = 3003.347 uV, v_off_fin = 3000.615 uV 17:18:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.465 uVs 17:18:46 Integrated Voltage Measurement... 17:18:55 Voltage Offset Correction: v_off_ini = 3007.987 uV, v_off_fin = 2977.624 uV 17:18:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.380 uVs 17:18:56 Integrated Voltage Measurement... 17:19:04 Voltage Offset Correction: v_off_ini = 3008.529 uV, v_off_fin = 3011.721 uV 17:19:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.997 uVs 17:19:07 I2Y Average and RMS of Measurements VT = -290.843 +- 7.435 uVs I2Y = -26.758 +- 0.684 uTm^2 17:19:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:19:19 Integrated Voltage Measurement... 17:19:28 Voltage Offset Correction: v_off_ini = 3005.859 uV, v_off_fin = 3024.987 uV 17:19:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.190 uVs 17:19:28 Integrated Voltage Measurement... 17:19:37 Voltage Offset Correction: v_off_ini = 3006.972 uV, v_off_fin = 2993.956 uV 17:19:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.941 uVs 17:19:37 Integrated Voltage Measurement... 17:19:46 Voltage Offset Correction: v_off_ini = 2990.286 uV, v_off_fin = 2990.494 uV 17:19:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -123.674 uVs 17:19:46 Integrated Voltage Measurement... 17:19:55 Voltage Offset Correction: v_off_ini = 3002.262 uV, v_off_fin = 2974.190 uV 17:19:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 131.710 uVs 17:19:55 Integrated Voltage Measurement... 17:20:04 Voltage Offset Correction: v_off_ini = 2973.385 uV, v_off_fin = 2977.331 uV 17:20:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.064 uVs 17:20:04 Integrated Voltage Measurement... 17:20:13 Voltage Offset Correction: v_off_ini = 2999.191 uV, v_off_fin = 3015.000 uV 17:20:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 172.013 uVs 17:20:17 I1X Average and RMS of Measurements VT = -142.932 +- 10.785 uVs I1X = 28.588 +- 2.155 uTm 17:20:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:20:24 Integrated Voltage Measurement... 17:20:33 Voltage Offset Correction: v_off_ini = 3023.459 uV, v_off_fin = 3001.322 uV 17:20:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.768 uVs 17:20:33 Integrated Voltage Measurement... 17:20:42 Voltage Offset Correction: v_off_ini = 2995.776 uV, v_off_fin = 3003.913 uV 17:20:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.431 uVs 17:20:42 Integrated Voltage Measurement... 17:20:51 Voltage Offset Correction: v_off_ini = 2977.641 uV, v_off_fin = 2950.172 uV 17:20:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.712 uVs 17:20:51 Integrated Voltage Measurement... 17:21:00 Voltage Offset Correction: v_off_ini = 2943.068 uV, v_off_fin = 2992.271 uV 17:21:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.254 uVs 17:21:00 Integrated Voltage Measurement... 17:21:09 Voltage Offset Correction: v_off_ini = 2957.027 uV, v_off_fin = 2952.099 uV 17:21:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.152 uVs 17:21:09 Integrated Voltage Measurement... 17:21:18 Voltage Offset Correction: v_off_ini = 2964.405 uV, v_off_fin = 2980.830 uV 17:21:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.020 uVs 17:21:22 I1Y Average and RMS of Measurements VT = -237.889 +- 7.317 uVs I1Y = -47.578 +- 1.463 uTm 17:21:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:21:27 Integrated Voltage Measurement... 17:21:36 Voltage Offset Correction: v_off_ini = 2944.135 uV, v_off_fin = 2954.519 uV 17:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.361 uVs 17:21:36 Integrated Voltage Measurement... 17:21:45 Voltage Offset Correction: v_off_ini = 2979.561 uV, v_off_fin = 3005.471 uV 17:21:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.693 uVs 17:21:45 Integrated Voltage Measurement... 17:21:54 Voltage Offset Correction: v_off_ini = 2956.324 uV, v_off_fin = 2957.453 uV 17:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.822 uVs 17:21:54 Integrated Voltage Measurement... 17:22:03 Voltage Offset Correction: v_off_ini = 2971.875 uV, v_off_fin = 2997.171 uV 17:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.025 uVs 17:22:03 Integrated Voltage Measurement... 17:22:12 Voltage Offset Correction: v_off_ini = 3009.200 uV, v_off_fin = 3012.622 uV 17:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.627 uVs 17:22:12 Integrated Voltage Measurement... 17:22:21 Voltage Offset Correction: v_off_ini = 2998.750 uV, v_off_fin = 3020.610 uV 17:22:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.455 uVs 17:22:24 I2X Average and RMS of Measurements VT = -113.331 +- 6.978 uVs I2X = 10.426 +- 0.642 uTm^2 17:22:26 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:22:29 Integrated Voltage Measurement... 17:22:38 Voltage Offset Correction: v_off_ini = 2989.083 uV, v_off_fin = 3007.277 uV 17:22:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.194 uVs 17:22:38 Integrated Voltage Measurement... 17:22:47 Voltage Offset Correction: v_off_ini = 2990.628 uV, v_off_fin = 3007.591 uV 17:22:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.031 uVs 17:22:47 Integrated Voltage Measurement... 17:22:56 Voltage Offset Correction: v_off_ini = 3030.129 uV, v_off_fin = 3004.812 uV 17:22:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.338 uVs 17:22:56 Integrated Voltage Measurement... 17:23:05 Voltage Offset Correction: v_off_ini = 2992.681 uV, v_off_fin = 3007.478 uV 17:23:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.070 uVs 17:23:05 Integrated Voltage Measurement... 17:23:14 Voltage Offset Correction: v_off_ini = 3002.566 uV, v_off_fin = 3002.449 uV 17:23:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.367 uVs 17:23:14 Integrated Voltage Measurement... 17:23:23 Voltage Offset Correction: v_off_ini = 3003.967 uV, v_off_fin = 2994.320 uV 17:23:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.844 uVs 17:23:25 I2Y Average and RMS of Measurements VT = -239.807 +- 9.397 uVs I2Y = -22.062 +- 0.864 uTm^2 17:23:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:23:34 Integrated Voltage Measurement... 17:23:42 Voltage Offset Correction: v_off_ini = 2995.921 uV, v_off_fin = 3007.955 uV 17:23:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.757 uVs 17:23:43 Integrated Voltage Measurement... 17:23:51 Voltage Offset Correction: v_off_ini = 3012.067 uV, v_off_fin = 3009.997 uV 17:23:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.752 uVs 17:23:52 Integrated Voltage Measurement... 17:24:01 Voltage Offset Correction: v_off_ini = 2987.584 uV, v_off_fin = 2968.860 uV 17:24:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.081 uVs 17:24:01 Integrated Voltage Measurement... 17:24:10 Voltage Offset Correction: v_off_ini = 2983.678 uV, v_off_fin = 2980.550 uV 17:24:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.691 uVs 17:24:10 Integrated Voltage Measurement... 17:24:19 Voltage Offset Correction: v_off_ini = 2985.470 uV, v_off_fin = 2959.822 uV 17:24:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -151.262 uVs 17:24:19 Integrated Voltage Measurement... 17:24:28 Voltage Offset Correction: v_off_ini = 2941.727 uV, v_off_fin = 2970.937 uV 17:24:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 153.334 uVs 17:24:32 I1X Average and RMS of Measurements VT = -131.146 +- 15.660 uVs I1X = 26.231 +- 3.134 uTm 17:24:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:24:39 Integrated Voltage Measurement... 17:24:47 Voltage Offset Correction: v_off_ini = 2992.807 uV, v_off_fin = 2962.291 uV 17:24:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.647 uVs 17:24:48 Integrated Voltage Measurement... 17:24:56 Voltage Offset Correction: v_off_ini = 3018.152 uV, v_off_fin = 3021.779 uV 17:24:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.914 uVs 17:24:57 Integrated Voltage Measurement... 17:25:05 Voltage Offset Correction: v_off_ini = 2991.405 uV, v_off_fin = 2991.801 uV 17:25:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.815 uVs 17:25:06 Integrated Voltage Measurement... 17:25:14 Voltage Offset Correction: v_off_ini = 3001.131 uV, v_off_fin = 2994.363 uV 17:25:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.458 uVs 17:25:15 Integrated Voltage Measurement... 17:25:23 Voltage Offset Correction: v_off_ini = 2995.168 uV, v_off_fin = 2990.768 uV 17:25:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.601 uVs 17:25:24 Integrated Voltage Measurement... 17:25:32 Voltage Offset Correction: v_off_ini = 2983.277 uV, v_off_fin = 2988.154 uV 17:25:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.005 uVs 17:25:37 I1Y Average and RMS of Measurements VT = -233.073 +- 6.329 uVs I1Y = -46.615 +- 1.266 uTm 17:25:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:25:42 Integrated Voltage Measurement... 17:25:51 Voltage Offset Correction: v_off_ini = 3023.529 uV, v_off_fin = 3018.140 uV 17:25:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.768 uVs 17:25:51 Integrated Voltage Measurement... 17:26:00 Voltage Offset Correction: v_off_ini = 3003.297 uV, v_off_fin = 3036.713 uV 17:26:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.383 uVs 17:26:00 Integrated Voltage Measurement... 17:26:09 Voltage Offset Correction: v_off_ini = 3028.837 uV, v_off_fin = 3024.381 uV 17:26:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.637 uVs 17:26:09 Integrated Voltage Measurement... 17:26:18 Voltage Offset Correction: v_off_ini = 3030.727 uV, v_off_fin = 3055.760 uV 17:26:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.698 uVs 17:26:18 Integrated Voltage Measurement... 17:26:27 Voltage Offset Correction: v_off_ini = 3048.449 uV, v_off_fin = 3047.614 uV 17:26:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.909 uVs 17:26:27 Integrated Voltage Measurement... 17:26:36 Voltage Offset Correction: v_off_ini = 3039.276 uV, v_off_fin = 3046.330 uV 17:26:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.530 uVs 17:26:38 I2X Average and RMS of Measurements VT = -102.321 +- 18.027 uVs I2X = 9.414 +- 1.659 uTm^2 17:26:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:26:43 Integrated Voltage Measurement... 17:26:52 Voltage Offset Correction: v_off_ini = 3064.417 uV, v_off_fin = 3071.056 uV 17:26:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.727 uVs 17:26:53 Integrated Voltage Measurement... 17:27:01 Voltage Offset Correction: v_off_ini = 3070.944 uV, v_off_fin = 3076.850 uV 17:27:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.887 uVs 17:27:02 Integrated Voltage Measurement... 17:27:11 Voltage Offset Correction: v_off_ini = 3076.192 uV, v_off_fin = 3082.902 uV 17:27:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.234 uVs 17:27:11 Integrated Voltage Measurement... 17:27:20 Voltage Offset Correction: v_off_ini = 3083.740 uV, v_off_fin = 3112.368 uV 17:27:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.807 uVs 17:27:20 Integrated Voltage Measurement... 17:27:29 Voltage Offset Correction: v_off_ini = 3103.287 uV, v_off_fin = 3081.993 uV 17:27:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.391 uVs 17:27:29 Integrated Voltage Measurement... 17:27:38 Voltage Offset Correction: v_off_ini = 3086.081 uV, v_off_fin = 3116.427 uV 17:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.411 uVs 17:27:40 I2Y Average and RMS of Measurements VT = -255.910 +- 3.054 uVs I2Y = -23.544 +- 0.281 uTm^2 17:27:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:27:48 Integrated Voltage Measurement... 17:27:57 Voltage Offset Correction: v_off_ini = 3094.989 uV, v_off_fin = 3078.796 uV 17:27:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -125.120 uVs 17:27:57 Integrated Voltage Measurement... 17:28:06 Voltage Offset Correction: v_off_ini = 3081.263 uV, v_off_fin = 3094.700 uV 17:28:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.342 uVs 17:28:06 Integrated Voltage Measurement... 17:28:15 Voltage Offset Correction: v_off_ini = 3113.465 uV, v_off_fin = 3093.517 uV 17:28:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.803 uVs 17:28:15 Integrated Voltage Measurement... 17:28:24 Voltage Offset Correction: v_off_ini = 3083.072 uV, v_off_fin = 3114.519 uV 17:28:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.498 uVs 17:28:24 Integrated Voltage Measurement... 17:28:33 Voltage Offset Correction: v_off_ini = 3091.482 uV, v_off_fin = 3090.125 uV 17:28:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.289 uVs 17:28:33 Integrated Voltage Measurement... 17:28:42 Voltage Offset Correction: v_off_ini = 3108.802 uV, v_off_fin = 3120.707 uV 17:28:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.791 uVs 17:28:46 I1X Average and RMS of Measurements VT = -123.474 +- 5.163 uVs I1X = 24.695 +- 1.033 uTm 17:28:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:28:53 Integrated Voltage Measurement... 17:29:02 Voltage Offset Correction: v_off_ini = 3114.958 uV, v_off_fin = 3107.691 uV 17:29:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.515 uVs 17:29:02 Integrated Voltage Measurement... 17:29:11 Voltage Offset Correction: v_off_ini = 3096.172 uV, v_off_fin = 3109.198 uV 17:29:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.869 uVs 17:29:11 Integrated Voltage Measurement... 17:29:20 Voltage Offset Correction: v_off_ini = 3103.956 uV, v_off_fin = 3100.770 uV 17:29:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.851 uVs 17:29:20 Integrated Voltage Measurement... 17:29:29 Voltage Offset Correction: v_off_ini = 3113.791 uV, v_off_fin = 3093.704 uV 17:29:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.773 uVs 17:29:29 Integrated Voltage Measurement... 17:29:38 Voltage Offset Correction: v_off_ini = 3094.867 uV, v_off_fin = 3090.102 uV 17:29:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.018 uVs 17:29:38 Integrated Voltage Measurement... 17:29:47 Voltage Offset Correction: v_off_ini = 3119.436 uV, v_off_fin = 3097.581 uV 17:29:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.117 uVs 17:29:51 I1Y Average and RMS of Measurements VT = -239.857 +- 7.470 uVs I1Y = -47.971 +- 1.494 uTm 17:29:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:29:56 Integrated Voltage Measurement... 17:30:05 Voltage Offset Correction: v_off_ini = 3115.679 uV, v_off_fin = 3114.618 uV 17:30:05 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -142.678 uVs 17:30:05 Integrated Voltage Measurement... 17:30:14 Voltage Offset Correction: v_off_ini = 3140.625 uV, v_off_fin = 3150.480 uV 17:30:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.672 uVs 17:30:15 Integrated Voltage Measurement... 17:30:24 Voltage Offset Correction: v_off_ini = 3126.439 uV, v_off_fin = 3099.888 uV 17:30:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.413 uVs 17:30:24 Integrated Voltage Measurement... 17:30:33 Voltage Offset Correction: v_off_ini = 3147.983 uV, v_off_fin = 3137.043 uV 17:30:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.997 uVs 17:30:33 Integrated Voltage Measurement... 17:30:42 Voltage Offset Correction: v_off_ini = 3136.536 uV, v_off_fin = 3111.050 uV 17:30:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.622 uVs 17:30:42 Integrated Voltage Measurement... 17:30:51 Voltage Offset Correction: v_off_ini = 3099.531 uV, v_off_fin = 3140.380 uV 17:30:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.835 uVs 17:30:53 I2X Average and RMS of Measurements VT = -108.036 +- 10.016 uVs I2X = 9.939 +- 0.921 uTm^2 17:30:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:30:58 Integrated Voltage Measurement... 17:31:07 Voltage Offset Correction: v_off_ini = 3142.516 uV, v_off_fin = 3124.838 uV 17:31:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.275 uVs 17:31:07 Integrated Voltage Measurement... 17:31:16 Voltage Offset Correction: v_off_ini = 3095.758 uV, v_off_fin = 3141.584 uV 17:31:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.054 uVs 17:31:16 Integrated Voltage Measurement... 17:31:25 Voltage Offset Correction: v_off_ini = 3138.270 uV, v_off_fin = 3125.376 uV 17:31:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.261 uVs 17:31:25 Integrated Voltage Measurement... 17:31:34 Voltage Offset Correction: v_off_ini = 3129.177 uV, v_off_fin = 3113.669 uV 17:31:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.176 uVs 17:31:34 Integrated Voltage Measurement... 17:31:43 Voltage Offset Correction: v_off_ini = 3099.284 uV, v_off_fin = 3102.975 uV 17:31:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.592 uVs 17:31:43 Integrated Voltage Measurement... 17:31:52 Voltage Offset Correction: v_off_ini = 3113.607 uV, v_off_fin = 3117.629 uV 17:31:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.448 uVs 17:31:55 I2Y Average and RMS of Measurements VT = -263.301 +- 3.233 uVs I2Y = -24.224 +- 0.297 uTm^2 17:31:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:32:03 Integrated Voltage Measurement... 17:32:12 Voltage Offset Correction: v_off_ini = 3106.264 uV, v_off_fin = 3108.138 uV 17:32:12 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -129.184 uVs 17:32:12 Integrated Voltage Measurement... 17:32:21 Voltage Offset Correction: v_off_ini = 3117.197 uV, v_off_fin = 3118.125 uV 17:32:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 128.361 uVs 17:32:21 Integrated Voltage Measurement... 17:32:30 Voltage Offset Correction: v_off_ini = 3102.718 uV, v_off_fin = 3099.301 uV 17:32:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.218 uVs 17:32:30 Integrated Voltage Measurement... 17:32:39 Voltage Offset Correction: v_off_ini = 3102.648 uV, v_off_fin = 3106.240 uV 17:32:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.865 uVs 17:32:39 Integrated Voltage Measurement... 17:32:48 Voltage Offset Correction: v_off_ini = 3090.505 uV, v_off_fin = 3089.920 uV 17:32:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.552 uVs 17:32:48 Integrated Voltage Measurement... 17:32:57 Voltage Offset Correction: v_off_ini = 3102.845 uV, v_off_fin = 3104.032 uV 17:32:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.442 uVs 17:33:01 I1X Average and RMS of Measurements VT = -125.604 +- 4.641 uVs I1X = 25.123 +- 0.930 uTm 17:33:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:33:08 Integrated Voltage Measurement... 17:33:17 Voltage Offset Correction: v_off_ini = 3086.902 uV, v_off_fin = 3069.134 uV 17:33:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.855 uVs 17:33:17 Integrated Voltage Measurement... 17:33:26 Voltage Offset Correction: v_off_ini = 3092.330 uV, v_off_fin = 3094.509 uV 17:33:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.609 uVs 17:33:26 Integrated Voltage Measurement... 17:33:35 Voltage Offset Correction: v_off_ini = 3088.189 uV, v_off_fin = 3102.730 uV 17:33:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.067 uVs 17:33:35 Integrated Voltage Measurement... 17:33:44 Voltage Offset Correction: v_off_ini = 3105.164 uV, v_off_fin = 3114.997 uV 17:33:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.885 uVs 17:33:44 Integrated Voltage Measurement... 17:33:53 Voltage Offset Correction: v_off_ini = 3114.009 uV, v_off_fin = 3082.434 uV 17:33:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.283 uVs 17:33:53 Integrated Voltage Measurement... 17:34:02 Voltage Offset Correction: v_off_ini = 3092.176 uV, v_off_fin = 3111.138 uV 17:34:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.577 uVs 17:34:06 I1Y Average and RMS of Measurements VT = -239.212 +- 0.594 uVs I1Y = -47.843 +- 0.119 uTm 17:34:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:34:11 Integrated Voltage Measurement... 17:34:20 Voltage Offset Correction: v_off_ini = 3074.664 uV, v_off_fin = 3076.228 uV 17:34:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.230 uVs 17:34:20 Integrated Voltage Measurement... 17:34:29 Voltage Offset Correction: v_off_ini = 3101.982 uV, v_off_fin = 3086.323 uV 17:34:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.996 uVs 17:34:29 Integrated Voltage Measurement... 17:34:38 Voltage Offset Correction: v_off_ini = 3109.291 uV, v_off_fin = 3074.753 uV 17:34:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.458 uVs 17:34:38 Integrated Voltage Measurement... 17:34:47 Voltage Offset Correction: v_off_ini = 3080.205 uV, v_off_fin = 3093.191 uV 17:34:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.116 uVs 17:34:47 Integrated Voltage Measurement... 17:34:56 Voltage Offset Correction: v_off_ini = 3077.321 uV, v_off_fin = 3059.489 uV 17:34:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.322 uVs 17:34:56 Integrated Voltage Measurement... 17:35:05 Voltage Offset Correction: v_off_ini = 3074.218 uV, v_off_fin = 3079.533 uV 17:35:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.354 uVs 17:35:08 I2X Average and RMS of Measurements VT = -92.913 +- 14.026 uVs I2X = 8.548 +- 1.290 uTm^2 17:35:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:35:13 Integrated Voltage Measurement... 17:35:22 Voltage Offset Correction: v_off_ini = 3099.482 uV, v_off_fin = 3099.458 uV 17:35:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.287 uVs 17:35:22 Integrated Voltage Measurement... 17:35:31 Voltage Offset Correction: v_off_ini = 3098.992 uV, v_off_fin = 3106.300 uV 17:35:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.250 uVs 17:35:31 Integrated Voltage Measurement... 17:35:40 Voltage Offset Correction: v_off_ini = 3100.189 uV, v_off_fin = 3083.906 uV 17:35:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.068 uVs 17:35:40 Integrated Voltage Measurement... 17:35:49 Voltage Offset Correction: v_off_ini = 3095.997 uV, v_off_fin = 3069.366 uV 17:35:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.089 uVs 17:35:49 Integrated Voltage Measurement... 17:35:58 Voltage Offset Correction: v_off_ini = 3076.547 uV, v_off_fin = 3072.066 uV 17:35:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.923 uVs 17:35:58 Integrated Voltage Measurement... 17:36:07 Voltage Offset Correction: v_off_ini = 3079.596 uV, v_off_fin = 3065.243 uV 17:36:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.123 uVs 17:36:09 I2Y Average and RMS of Measurements VT = -244.790 +- 6.348 uVs I2Y = -22.521 +- 0.584 uTm^2 17:36:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:36:18 Integrated Voltage Measurement... 17:36:27 Voltage Offset Correction: v_off_ini = 3044.564 uV, v_off_fin = 3065.984 uV 17:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.961 uVs 17:36:27 Integrated Voltage Measurement... 17:36:36 Voltage Offset Correction: v_off_ini = 3071.019 uV, v_off_fin = 3067.193 uV 17:36:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.549 uVs 17:36:36 Integrated Voltage Measurement... 17:36:45 Voltage Offset Correction: v_off_ini = 3066.669 uV, v_off_fin = 3076.776 uV 17:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.374 uVs 17:36:45 Integrated Voltage Measurement... 17:36:54 Voltage Offset Correction: v_off_ini = 3054.969 uV, v_off_fin = 3073.812 uV 17:36:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.555 uVs 17:36:54 Integrated Voltage Measurement... 17:37:03 Voltage Offset Correction: v_off_ini = 3077.303 uV, v_off_fin = 3076.377 uV 17:37:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.652 uVs 17:37:03 Integrated Voltage Measurement... 17:37:12 Voltage Offset Correction: v_off_ini = 3099.789 uV, v_off_fin = 3106.714 uV 17:37:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.232 uVs 17:37:16 I1X Average and RMS of Measurements VT = -107.887 +- 3.497 uVs I1X = 21.578 +- 0.700 uTm 17:37:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:37:23 Integrated Voltage Measurement... 17:37:31 Voltage Offset Correction: v_off_ini = 3074.706 uV, v_off_fin = 3088.111 uV 17:37:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.181 uVs 17:37:32 Integrated Voltage Measurement... 17:37:40 Voltage Offset Correction: v_off_ini = 3084.709 uV, v_off_fin = 3089.702 uV 17:37:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.639 uVs 17:37:41 Integrated Voltage Measurement... 17:37:49 Voltage Offset Correction: v_off_ini = 3109.636 uV, v_off_fin = 3084.509 uV 17:37:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.843 uVs 17:37:50 Integrated Voltage Measurement... 17:37:58 Voltage Offset Correction: v_off_ini = 3058.914 uV, v_off_fin = 3083.731 uV 17:37:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.625 uVs 17:37:59 Integrated Voltage Measurement... 17:38:07 Voltage Offset Correction: v_off_ini = 3136.142 uV, v_off_fin = 3108.890 uV 17:38:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.862 uVs 17:38:08 Integrated Voltage Measurement... 17:38:16 Voltage Offset Correction: v_off_ini = 3082.455 uV, v_off_fin = 3096.063 uV 17:38:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.414 uVs 17:38:21 I1Y Average and RMS of Measurements VT = -249.927 +- 8.212 uVs I1Y = -49.985 +- 1.642 uTm 17:38:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:38:26 Integrated Voltage Measurement... 17:38:35 Voltage Offset Correction: v_off_ini = 3080.703 uV, v_off_fin = 3052.012 uV 17:38:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.969 uVs 17:38:35 Integrated Voltage Measurement... 17:38:44 Voltage Offset Correction: v_off_ini = 3095.299 uV, v_off_fin = 3111.121 uV 17:38:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.420 uVs 17:38:44 Integrated Voltage Measurement... 17:38:53 Voltage Offset Correction: v_off_ini = 3100.278 uV, v_off_fin = 3111.442 uV 17:38:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.605 uVs 17:38:53 Integrated Voltage Measurement... 17:39:02 Voltage Offset Correction: v_off_ini = 3113.633 uV, v_off_fin = 3126.854 uV 17:39:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.544 uVs 17:39:02 Integrated Voltage Measurement... 17:39:11 Voltage Offset Correction: v_off_ini = 3130.030 uV, v_off_fin = 3111.281 uV 17:39:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.000 uVs 17:39:11 Integrated Voltage Measurement... 17:39:20 Voltage Offset Correction: v_off_ini = 3091.759 uV, v_off_fin = 3132.375 uV 17:39:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.971 uVs 17:39:22 I2X Average and RMS of Measurements VT = -63.918 +- 13.320 uVs I2X = 5.880 +- 1.225 uTm^2 17:39:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:39:27 Integrated Voltage Measurement... 17:39:36 Voltage Offset Correction: v_off_ini = 3101.914 uV, v_off_fin = 3092.990 uV 17:39:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.971 uVs 17:39:36 Integrated Voltage Measurement... 17:39:45 Voltage Offset Correction: v_off_ini = 3085.653 uV, v_off_fin = 3064.545 uV 17:39:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.214 uVs 17:39:46 Integrated Voltage Measurement... 17:39:54 Voltage Offset Correction: v_off_ini = 3054.613 uV, v_off_fin = 3052.184 uV 17:39:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.785 uVs 17:39:55 Integrated Voltage Measurement... 17:40:04 Voltage Offset Correction: v_off_ini = 3054.411 uV, v_off_fin = 3069.919 uV 17:40:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.781 uVs 17:40:04 Integrated Voltage Measurement... 17:40:13 Voltage Offset Correction: v_off_ini = 3040.325 uV, v_off_fin = 3039.012 uV 17:40:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.580 uVs 17:40:13 Integrated Voltage Measurement... 17:40:22 Voltage Offset Correction: v_off_ini = 3068.017 uV, v_off_fin = 3065.368 uV 17:40:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.387 uVs 17:40:24 I2Y Average and RMS of Measurements VT = -259.453 +- 10.516 uVs I2Y = -23.870 +- 0.968 uTm^2 17:40:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:40:44 Integrated Voltage Measurement... 17:40:53 Voltage Offset Correction: v_off_ini = 3024.876 uV, v_off_fin = 3018.295 uV 17:40:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.676 uVs 17:40:53 Integrated Voltage Measurement... 17:41:02 Voltage Offset Correction: v_off_ini = 3035.184 uV, v_off_fin = 3025.144 uV 17:41:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.942 uVs 17:41:02 Integrated Voltage Measurement... 17:41:11 Voltage Offset Correction: v_off_ini = 3005.550 uV, v_off_fin = 2992.660 uV 17:41:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.075 uVs 17:41:11 Integrated Voltage Measurement... 17:41:20 Voltage Offset Correction: v_off_ini = 3035.652 uV, v_off_fin = 3043.083 uV 17:41:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 163.089 uVs 17:41:20 Integrated Voltage Measurement... 17:41:29 Voltage Offset Correction: v_off_ini = 3041.831 uV, v_off_fin = 3022.908 uV 17:41:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.239 uVs 17:41:29 Integrated Voltage Measurement... 17:41:38 Voltage Offset Correction: v_off_ini = 3063.302 uV, v_off_fin = 3057.451 uV 17:41:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.038 uVs 17:41:42 I1X Average and RMS of Measurements VT = -147.177 +- 3.340 uVs I1X = 29.435 +- 0.668 uTm 17:41:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:41:49 Integrated Voltage Measurement... 17:41:58 Voltage Offset Correction: v_off_ini = 3035.579 uV, v_off_fin = 3048.070 uV 17:41:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.093 uVs 17:41:58 Integrated Voltage Measurement... 17:42:07 Voltage Offset Correction: v_off_ini = 3087.407 uV, v_off_fin = 3086.288 uV 17:42:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.119 uVs 17:42:07 Integrated Voltage Measurement... 17:42:16 Voltage Offset Correction: v_off_ini = 3066.415 uV, v_off_fin = 3040.905 uV 17:42:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.584 uVs 17:42:16 Integrated Voltage Measurement... 17:42:25 Voltage Offset Correction: v_off_ini = 3076.136 uV, v_off_fin = 3083.878 uV 17:42:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.299 uVs 17:42:25 Integrated Voltage Measurement... 17:42:34 Voltage Offset Correction: v_off_ini = 3033.201 uV, v_off_fin = 3057.641 uV 17:42:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.665 uVs 17:42:34 Integrated Voltage Measurement... 17:42:43 Voltage Offset Correction: v_off_ini = 3043.110 uV, v_off_fin = 3061.629 uV 17:42:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.133 uVs 17:42:47 I1Y Average and RMS of Measurements VT = -194.982 +- 2.737 uVs I1Y = -38.996 +- 0.547 uTm 17:42:52 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:42:55 Integrated Voltage Measurement... 17:43:04 Voltage Offset Correction: v_off_ini = 3076.813 uV, v_off_fin = 3054.532 uV 17:43:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.931 uVs 17:43:04 Integrated Voltage Measurement... 17:43:13 Voltage Offset Correction: v_off_ini = 3051.844 uV, v_off_fin = 3066.202 uV 17:43:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.327 uVs 17:43:13 Integrated Voltage Measurement... 17:43:22 Voltage Offset Correction: v_off_ini = 3087.997 uV, v_off_fin = 3067.823 uV 17:43:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -105.601 uVs 17:43:22 Integrated Voltage Measurement... 17:43:31 Voltage Offset Correction: v_off_ini = 3059.094 uV, v_off_fin = 3091.454 uV 17:43:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.643 uVs 17:43:31 Integrated Voltage Measurement... 17:43:40 Voltage Offset Correction: v_off_ini = 3086.025 uV, v_off_fin = 3073.773 uV 17:43:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.282 uVs 17:43:40 Integrated Voltage Measurement... 17:43:49 Voltage Offset Correction: v_off_ini = 3112.099 uV, v_off_fin = 3101.603 uV 17:43:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.329 uVs 17:43:51 I2X Average and RMS of Measurements VT = -112.852 +- 22.743 uVs I2X = 10.383 +- 2.092 uTm^2 17:43:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:43:59 Integrated Voltage Measurement... 17:44:08 Voltage Offset Correction: v_off_ini = 3061.519 uV, v_off_fin = 3057.155 uV 17:44:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.488 uVs 17:44:08 Integrated Voltage Measurement... 17:44:17 Voltage Offset Correction: v_off_ini = 3058.925 uV, v_off_fin = 3074.649 uV 17:44:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.059 uVs 17:44:17 Integrated Voltage Measurement... 17:44:26 Voltage Offset Correction: v_off_ini = 3069.784 uV, v_off_fin = 3089.391 uV 17:44:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.599 uVs 17:44:26 Integrated Voltage Measurement... 17:44:35 Voltage Offset Correction: v_off_ini = 3060.861 uV, v_off_fin = 3068.935 uV 17:44:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.299 uVs 17:44:35 Integrated Voltage Measurement... 17:44:44 Voltage Offset Correction: v_off_ini = 3084.424 uV, v_off_fin = 3058.339 uV 17:44:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.463 uVs 17:44:44 Integrated Voltage Measurement... 17:44:53 Voltage Offset Correction: v_off_ini = 3071.828 uV, v_off_fin = 3064.996 uV 17:44:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.012 uVs 17:44:56 I2Y Average and RMS of Measurements VT = -205.820 +- 1.931 uVs I2Y = -18.935 +- 0.178 uTm^2 17:45:00 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:45:05 Integrated Voltage Measurement... 17:45:13 Voltage Offset Correction: v_off_ini = 3090.863 uV, v_off_fin = 3053.419 uV 17:45:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.260 uVs 17:45:14 Integrated Voltage Measurement... 17:45:22 Voltage Offset Correction: v_off_ini = 3055.215 uV, v_off_fin = 3088.881 uV 17:45:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.070 uVs 17:45:23 Integrated Voltage Measurement... 17:45:32 Voltage Offset Correction: v_off_ini = 3080.637 uV, v_off_fin = 3085.207 uV 17:45:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.636 uVs 17:45:32 Integrated Voltage Measurement... 17:45:41 Voltage Offset Correction: v_off_ini = 3065.014 uV, v_off_fin = 3085.733 uV 17:45:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.637 uVs 17:45:41 Integrated Voltage Measurement... 17:45:50 Voltage Offset Correction: v_off_ini = 3093.099 uV, v_off_fin = 3079.098 uV 17:45:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -166.647 uVs 17:45:50 Integrated Voltage Measurement... 17:45:59 Voltage Offset Correction: v_off_ini = 3091.207 uV, v_off_fin = 3097.843 uV 17:45:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.656 uVs 17:46:03 I1X Average and RMS of Measurements VT = -150.651 +- 11.907 uVs I1X = 30.131 +- 2.382 uTm 17:46:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:46:10 Integrated Voltage Measurement... 17:46:19 Voltage Offset Correction: v_off_ini = 3101.374 uV, v_off_fin = 3064.761 uV 17:46:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.768 uVs 17:46:19 Integrated Voltage Measurement... 17:46:27 Voltage Offset Correction: v_off_ini = 3083.027 uV, v_off_fin = 3116.783 uV 17:46:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.607 uVs 17:46:28 Integrated Voltage Measurement... 17:46:36 Voltage Offset Correction: v_off_ini = 3069.339 uV, v_off_fin = 3077.899 uV 17:46:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.046 uVs 17:46:37 Integrated Voltage Measurement... 17:46:45 Voltage Offset Correction: v_off_ini = 3093.719 uV, v_off_fin = 3087.962 uV 17:46:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.702 uVs 17:46:46 Integrated Voltage Measurement... 17:46:54 Voltage Offset Correction: v_off_ini = 3104.646 uV, v_off_fin = 3084.704 uV 17:46:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.053 uVs 17:46:54 Integrated Voltage Measurement... 17:47:03 Voltage Offset Correction: v_off_ini = 3097.803 uV, v_off_fin = 3132.352 uV 17:47:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.335 uVs 17:47:08 I1Y Average and RMS of Measurements VT = -213.085 +- 2.161 uVs I1Y = -42.618 +- 0.432 uTm 17:47:13 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:47:15 Integrated Voltage Measurement... 17:47:24 Voltage Offset Correction: v_off_ini = 3109.722 uV, v_off_fin = 3118.155 uV 17:47:24 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -127.676 uVs 17:47:24 Integrated Voltage Measurement... 17:47:33 Voltage Offset Correction: v_off_ini = 3159.105 uV, v_off_fin = 3147.040 uV 17:47:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.470 uVs 17:47:33 Integrated Voltage Measurement... 17:47:42 Voltage Offset Correction: v_off_ini = 3132.375 uV, v_off_fin = 3126.860 uV 17:47:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.749 uVs 17:47:42 Integrated Voltage Measurement... 17:47:51 Voltage Offset Correction: v_off_ini = 3125.361 uV, v_off_fin = 3122.967 uV 17:47:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.444 uVs 17:47:51 Integrated Voltage Measurement... 17:48:00 Voltage Offset Correction: v_off_ini = 3129.348 uV, v_off_fin = 3129.170 uV 17:48:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.472 uVs 17:48:01 Integrated Voltage Measurement... 17:48:09 Voltage Offset Correction: v_off_ini = 3107.092 uV, v_off_fin = 3143.970 uV 17:48:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.117 uVs 17:48:12 I2X Average and RMS of Measurements VT = -103.988 +- 4.874 uVs I2X = 9.567 +- 0.448 uTm^2 17:48:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:48:20 Integrated Voltage Measurement... 17:48:29 Voltage Offset Correction: v_off_ini = 3120.960 uV, v_off_fin = 3106.604 uV 17:48:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -207.733 uVs 17:48:29 Integrated Voltage Measurement... 17:48:38 Voltage Offset Correction: v_off_ini = 3158.787 uV, v_off_fin = 3159.900 uV 17:48:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.903 uVs 17:48:38 Integrated Voltage Measurement... 17:48:47 Voltage Offset Correction: v_off_ini = 3136.801 uV, v_off_fin = 3126.273 uV 17:48:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.688 uVs 17:48:47 Integrated Voltage Measurement... 17:48:56 Voltage Offset Correction: v_off_ini = 3128.151 uV, v_off_fin = 3141.145 uV 17:48:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.271 uVs 17:48:56 Integrated Voltage Measurement... 17:49:05 Voltage Offset Correction: v_off_ini = 3165.763 uV, v_off_fin = 3157.114 uV 17:49:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.173 uVs 17:49:05 Integrated Voltage Measurement... 17:49:14 Voltage Offset Correction: v_off_ini = 3143.142 uV, v_off_fin = 3119.764 uV 17:49:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.415 uVs 17:49:16 I2Y Average and RMS of Measurements VT = -213.530 +- 9.058 uVs I2Y = -19.645 +- 0.834 uTm^2 17:49:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:49:25 Integrated Voltage Measurement... 17:49:34 Voltage Offset Correction: v_off_ini = 3105.589 uV, v_off_fin = 3099.927 uV 17:49:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.451 uVs 17:49:34 Integrated Voltage Measurement... 17:49:43 Voltage Offset Correction: v_off_ini = 3127.266 uV, v_off_fin = 3121.291 uV 17:49:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.589 uVs 17:49:43 Integrated Voltage Measurement... 17:49:52 Voltage Offset Correction: v_off_ini = 3099.912 uV, v_off_fin = 3090.140 uV 17:49:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.694 uVs 17:49:52 Integrated Voltage Measurement... 17:50:01 Voltage Offset Correction: v_off_ini = 3083.794 uV, v_off_fin = 3095.757 uV 17:50:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.211 uVs 17:50:01 Integrated Voltage Measurement... 17:50:10 Voltage Offset Correction: v_off_ini = 3116.493 uV, v_off_fin = 3113.698 uV 17:50:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.900 uVs 17:50:10 Integrated Voltage Measurement... 17:50:19 Voltage Offset Correction: v_off_ini = 3082.537 uV, v_off_fin = 3093.307 uV 17:50:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 180.547 uVs 17:50:23 I1X Average and RMS of Measurements VT = -149.065 +- 5.712 uVs I1X = 29.813 +- 1.142 uTm 17:50:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:50:30 Integrated Voltage Measurement... 17:50:39 Voltage Offset Correction: v_off_ini = 3082.982 uV, v_off_fin = 3080.746 uV 17:50:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -221.856 uVs 17:50:39 Integrated Voltage Measurement... 17:50:48 Voltage Offset Correction: v_off_ini = 3088.115 uV, v_off_fin = 3100.243 uV 17:50:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.446 uVs 17:50:48 Integrated Voltage Measurement... 17:50:57 Voltage Offset Correction: v_off_ini = 3092.570 uV, v_off_fin = 3091.522 uV 17:50:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.093 uVs 17:50:57 Integrated Voltage Measurement... 17:51:06 Voltage Offset Correction: v_off_ini = 3103.252 uV, v_off_fin = 3108.936 uV 17:51:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.258 uVs 17:51:06 Integrated Voltage Measurement... 17:51:15 Voltage Offset Correction: v_off_ini = 3088.866 uV, v_off_fin = 3107.615 uV 17:51:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.590 uVs 17:51:15 Integrated Voltage Measurement... 17:51:24 Voltage Offset Correction: v_off_ini = 3094.393 uV, v_off_fin = 3087.635 uV 17:51:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.811 uVs 17:51:28 I1Y Average and RMS of Measurements VT = -221.842 +- 2.879 uVs I1Y = -44.369 +- 0.575 uTm 17:51:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:51:36 Integrated Voltage Measurement... 17:51:45 Voltage Offset Correction: v_off_ini = 3066.262 uV, v_off_fin = 3081.220 uV 17:51:45 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -96.890 uVs 17:51:45 Integrated Voltage Measurement... 17:51:54 Voltage Offset Correction: v_off_ini = 3100.999 uV, v_off_fin = 3109.499 uV 17:51:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.540 uVs 17:51:54 Integrated Voltage Measurement... 17:52:03 Voltage Offset Correction: v_off_ini = 3084.528 uV, v_off_fin = 3097.720 uV 17:52:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.613 uVs 17:52:03 Integrated Voltage Measurement... 17:52:12 Voltage Offset Correction: v_off_ini = 3081.443 uV, v_off_fin = 3104.676 uV 17:52:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.782 uVs 17:52:12 Integrated Voltage Measurement... 17:52:21 Voltage Offset Correction: v_off_ini = 3074.330 uV, v_off_fin = 3080.170 uV 17:52:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.127 uVs 17:52:21 Integrated Voltage Measurement... 17:52:30 Voltage Offset Correction: v_off_ini = 3093.198 uV, v_off_fin = 3113.726 uV 17:52:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.458 uVs 17:52:32 I2X Average and RMS of Measurements VT = -113.235 +- 5.769 uVs I2X = 10.417 +- 0.531 uTm^2 17:52:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:52:40 Integrated Voltage Measurement... 17:52:49 Voltage Offset Correction: v_off_ini = 3092.842 uV, v_off_fin = 3088.635 uV 17:52:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.228 uVs 17:52:49 Integrated Voltage Measurement... 17:52:58 Voltage Offset Correction: v_off_ini = 3101.388 uV, v_off_fin = 3091.532 uV 17:52:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.925 uVs 17:52:58 Integrated Voltage Measurement... 17:53:07 Voltage Offset Correction: v_off_ini = 3112.473 uV, v_off_fin = 3098.950 uV 17:53:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.138 uVs 17:53:07 Integrated Voltage Measurement... 17:53:16 Voltage Offset Correction: v_off_ini = 3099.090 uV, v_off_fin = 3110.810 uV 17:53:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.217 uVs 17:53:16 Integrated Voltage Measurement... 17:53:25 Voltage Offset Correction: v_off_ini = 3107.878 uV, v_off_fin = 3094.487 uV 17:53:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.138 uVs 17:53:25 Integrated Voltage Measurement... 17:53:34 Voltage Offset Correction: v_off_ini = 3131.020 uV, v_off_fin = 3132.421 uV 17:53:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.960 uVs 17:53:37 I2Y Average and RMS of Measurements VT = -236.268 +- 7.625 uVs I2Y = -21.737 +- 0.702 uTm^2 17:53:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:53:46 Integrated Voltage Measurement... 17:53:55 Voltage Offset Correction: v_off_ini = 3103.622 uV, v_off_fin = 3103.277 uV 17:53:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -184.949 uVs 17:53:55 Integrated Voltage Measurement... 17:54:04 Voltage Offset Correction: v_off_ini = 3105.285 uV, v_off_fin = 3105.721 uV 17:54:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 179.749 uVs 17:54:04 Integrated Voltage Measurement... 17:54:13 Voltage Offset Correction: v_off_ini = 3082.419 uV, v_off_fin = 3063.046 uV 17:54:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.843 uVs 17:54:13 Integrated Voltage Measurement... 17:54:22 Voltage Offset Correction: v_off_ini = 3073.497 uV, v_off_fin = 3073.150 uV 17:54:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 170.938 uVs 17:54:22 Integrated Voltage Measurement... 17:54:31 Voltage Offset Correction: v_off_ini = 3076.299 uV, v_off_fin = 3066.174 uV 17:54:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -190.167 uVs 17:54:31 Integrated Voltage Measurement... 17:54:40 Voltage Offset Correction: v_off_ini = 3105.444 uV, v_off_fin = 3112.263 uV 17:54:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.876 uVs 17:54:44 I1X Average and RMS of Measurements VT = -175.754 +- 16.642 uVs I1X = 35.151 +- 3.328 uTm 17:54:46 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:54:51 Integrated Voltage Measurement... 17:54:59 Voltage Offset Correction: v_off_ini = 3085.523 uV, v_off_fin = 3073.848 uV 17:54:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -239.494 uVs 17:54:59 Integrated Voltage Measurement... 17:55:08 Voltage Offset Correction: v_off_ini = 3073.183 uV, v_off_fin = 3078.811 uV 17:55:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.772 uVs 17:55:08 Integrated Voltage Measurement... 17:55:17 Voltage Offset Correction: v_off_ini = 3086.899 uV, v_off_fin = 3089.860 uV 17:55:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.436 uVs 17:55:17 Integrated Voltage Measurement... 17:55:26 Voltage Offset Correction: v_off_ini = 3079.384 uV, v_off_fin = 3104.833 uV 17:55:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.628 uVs 17:55:26 Integrated Voltage Measurement... 17:55:35 Voltage Offset Correction: v_off_ini = 3097.165 uV, v_off_fin = 3096.894 uV 17:55:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.960 uVs 17:55:35 Integrated Voltage Measurement... 17:55:44 Voltage Offset Correction: v_off_ini = 3110.731 uV, v_off_fin = 3126.012 uV 17:55:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.472 uVs 17:55:49 I1Y Average and RMS of Measurements VT = -248.460 +- 8.678 uVs I1Y = -49.693 +- 1.735 uTm 17:55:54 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:55:56 Integrated Voltage Measurement... 17:56:05 Voltage Offset Correction: v_off_ini = 3126.326 uV, v_off_fin = 3104.849 uV 17:56:05 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -116.822 uVs 17:56:05 Integrated Voltage Measurement... 17:56:14 Voltage Offset Correction: v_off_ini = 3115.777 uV, v_off_fin = 3103.052 uV 17:56:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.535 uVs 17:56:14 Integrated Voltage Measurement... 17:56:23 Voltage Offset Correction: v_off_ini = 3108.673 uV, v_off_fin = 3099.672 uV 17:56:23 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -114.976 uVs 17:56:23 Integrated Voltage Measurement... 17:56:32 Voltage Offset Correction: v_off_ini = 3136.153 uV, v_off_fin = 3126.688 uV 17:56:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.515 uVs 17:56:32 Integrated Voltage Measurement... 17:56:41 Voltage Offset Correction: v_off_ini = 3113.490 uV, v_off_fin = 3098.066 uV 17:56:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.041 uVs 17:56:41 Integrated Voltage Measurement... 17:56:50 Voltage Offset Correction: v_off_ini = 3120.330 uV, v_off_fin = 3125.418 uV 17:56:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.186 uVs 17:56:53 I2X Average and RMS of Measurements VT = -113.513 +- 5.947 uVs I2X = 10.443 +- 0.548 uTm^2 17:56:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:57:01 Integrated Voltage Measurement... 17:57:09 Voltage Offset Correction: v_off_ini = 3095.977 uV, v_off_fin = 3103.104 uV 17:57:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.101 uVs 17:57:10 Integrated Voltage Measurement... 17:57:19 Voltage Offset Correction: v_off_ini = 3105.121 uV, v_off_fin = 3110.966 uV 17:57:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.550 uVs 17:57:19 Integrated Voltage Measurement... 17:57:28 Voltage Offset Correction: v_off_ini = 3118.438 uV, v_off_fin = 3123.794 uV 17:57:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.586 uVs 17:57:28 Integrated Voltage Measurement... 17:57:37 Voltage Offset Correction: v_off_ini = 3131.728 uV, v_off_fin = 3150.252 uV 17:57:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.615 uVs 17:57:37 Integrated Voltage Measurement... 17:57:46 Voltage Offset Correction: v_off_ini = 3157.469 uV, v_off_fin = 3148.436 uV 17:57:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.648 uVs 17:57:46 Integrated Voltage Measurement... 17:57:55 Voltage Offset Correction: v_off_ini = 3143.777 uV, v_off_fin = 3112.337 uV 17:57:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.155 uVs 17:57:57 I2Y Average and RMS of Measurements VT = -261.109 +- 10.150 uVs I2Y = -24.022 +- 0.934 uTm^2 17:58:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:58:06 Integrated Voltage Measurement... 17:58:15 Voltage Offset Correction: v_off_ini = 3126.640 uV, v_off_fin = 3129.918 uV 17:58:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -150.170 uVs 17:58:15 Integrated Voltage Measurement... 17:58:24 Voltage Offset Correction: v_off_ini = 3132.496 uV, v_off_fin = 3135.117 uV 17:58:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.543 uVs 17:58:24 Integrated Voltage Measurement... 17:58:33 Voltage Offset Correction: v_off_ini = 3128.301 uV, v_off_fin = 3113.586 uV 17:58:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -195.735 uVs 17:58:33 Integrated Voltage Measurement... 17:58:42 Voltage Offset Correction: v_off_ini = 3104.683 uV, v_off_fin = 3132.541 uV 17:58:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 174.133 uVs 17:58:42 Integrated Voltage Measurement... 17:58:51 Voltage Offset Correction: v_off_ini = 3125.045 uV, v_off_fin = 3116.032 uV 17:58:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.027 uVs 17:58:51 Integrated Voltage Measurement... 17:59:00 Voltage Offset Correction: v_off_ini = 3108.890 uV, v_off_fin = 3123.476 uV 17:59:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.438 uVs 17:59:04 I1X Average and RMS of Measurements VT = -176.341 +- 7.407 uVs I1X = 35.269 +- 1.480 uTm 17:59:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:59:11 Integrated Voltage Measurement... 17:59:20 Voltage Offset Correction: v_off_ini = 3146.714 uV, v_off_fin = 3124.169 uV 17:59:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.045 uVs 17:59:20 Integrated Voltage Measurement... 17:59:29 Voltage Offset Correction: v_off_ini = 3107.102 uV, v_off_fin = 3126.650 uV 17:59:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.256 uVs 17:59:29 Integrated Voltage Measurement... 17:59:38 Voltage Offset Correction: v_off_ini = 3147.691 uV, v_off_fin = 3133.431 uV 17:59:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.729 uVs 17:59:38 Integrated Voltage Measurement... 17:59:47 Voltage Offset Correction: v_off_ini = 3120.135 uV, v_off_fin = 3140.045 uV 17:59:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.675 uVs 17:59:47 Integrated Voltage Measurement... 17:59:56 Voltage Offset Correction: v_off_ini = 3142.487 uV, v_off_fin = 3132.790 uV 17:59:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.588 uVs 17:59:56 Integrated Voltage Measurement... 18:00:05 Voltage Offset Correction: v_off_ini = 3173.087 uV, v_off_fin = 3158.847 uV 18:00:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.181 uVs 18:00:09 I1Y Average and RMS of Measurements VT = -253.912 +- 11.779 uVs I1Y = -50.782 +- 2.356 uTm 18:00:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:00:17 Integrated Voltage Measurement... 18:00:26 Voltage Offset Correction: v_off_ini = 3166.677 uV, v_off_fin = 3170.947 uV 18:00:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.088 uVs 18:00:26 Integrated Voltage Measurement... 18:00:35 Voltage Offset Correction: v_off_ini = 3150.607 uV, v_off_fin = 3162.647 uV 18:00:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.166 uVs 18:00:35 Integrated Voltage Measurement... 18:00:44 Voltage Offset Correction: v_off_ini = 3139.082 uV, v_off_fin = 3137.842 uV 18:00:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.530 uVs 18:00:44 Integrated Voltage Measurement... 18:00:53 Voltage Offset Correction: v_off_ini = 3125.764 uV, v_off_fin = 3149.751 uV 18:00:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.940 uVs 18:00:53 Integrated Voltage Measurement... 18:01:02 Voltage Offset Correction: v_off_ini = 3127.693 uV, v_off_fin = 3117.611 uV 18:01:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.911 uVs 18:01:02 Integrated Voltage Measurement... 18:01:11 Voltage Offset Correction: v_off_ini = 3131.724 uV, v_off_fin = 3153.902 uV 18:01:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.686 uVs 18:01:13 I2X Average and RMS of Measurements VT = -125.553 +- 7.097 uVs I2X = 11.551 +- 0.653 uTm^2 18:01:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:01:21 Integrated Voltage Measurement... 18:01:30 Voltage Offset Correction: v_off_ini = 3152.371 uV, v_off_fin = 3181.086 uV 18:01:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.593 uVs 18:01:30 Integrated Voltage Measurement... 18:01:39 Voltage Offset Correction: v_off_ini = 3184.274 uV, v_off_fin = 3192.427 uV 18:01:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.647 uVs 18:01:39 Integrated Voltage Measurement... 18:01:48 Voltage Offset Correction: v_off_ini = 3189.682 uV, v_off_fin = 3186.562 uV 18:01:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.513 uVs 18:01:48 Integrated Voltage Measurement... 18:01:57 Voltage Offset Correction: v_off_ini = 3179.879 uV, v_off_fin = 3164.818 uV 18:01:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.173 uVs 18:01:57 Integrated Voltage Measurement... 18:02:06 Voltage Offset Correction: v_off_ini = 3164.511 uV, v_off_fin = 3180.482 uV 18:02:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.699 uVs 18:02:06 Integrated Voltage Measurement... 18:02:15 Voltage Offset Correction: v_off_ini = 3197.967 uV, v_off_fin = 3186.590 uV 18:02:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.014 uVs 18:02:18 I2Y Average and RMS of Measurements VT = -273.773 +- 2.138 uVs I2Y = -25.187 +- 0.197 uTm^2 18:02:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:02:29 Integrated Voltage Measurement... 18:02:38 Voltage Offset Correction: v_off_ini = 3161.800 uV, v_off_fin = 3176.973 uV 18:02:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.114 uVs 18:02:38 Integrated Voltage Measurement... 18:02:47 Voltage Offset Correction: v_off_ini = 3171.203 uV, v_off_fin = 3180.630 uV 18:02:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.797 uVs 18:02:47 Integrated Voltage Measurement... 18:02:56 Voltage Offset Correction: v_off_ini = 3207.156 uV, v_off_fin = 3184.651 uV 18:02:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.398 uVs 18:02:56 Integrated Voltage Measurement... 18:03:05 Voltage Offset Correction: v_off_ini = 3189.710 uV, v_off_fin = 3182.940 uV 18:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.261 uVs 18:03:05 Integrated Voltage Measurement... 18:03:14 Voltage Offset Correction: v_off_ini = 3177.740 uV, v_off_fin = 3159.371 uV 18:03:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.649 uVs 18:03:15 Integrated Voltage Measurement... 18:03:23 Voltage Offset Correction: v_off_ini = 3179.287 uV, v_off_fin = 3179.642 uV 18:03:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 139.513 uVs 18:03:28 I1X Average and RMS of Measurements VT = -156.622 +- 8.937 uVs I1X = 31.325 +- 1.788 uTm 18:03:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:03:34 Integrated Voltage Measurement... 18:03:43 Voltage Offset Correction: v_off_ini = 3171.661 uV, v_off_fin = 3175.104 uV 18:03:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.453 uVs 18:03:43 Integrated Voltage Measurement... 18:03:52 Voltage Offset Correction: v_off_ini = 3187.164 uV, v_off_fin = 3164.329 uV 18:03:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.648 uVs 18:03:52 Integrated Voltage Measurement... 18:04:01 Voltage Offset Correction: v_off_ini = 3186.255 uV, v_off_fin = 3177.767 uV 18:04:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.324 uVs 18:04:01 Integrated Voltage Measurement... 18:04:10 Voltage Offset Correction: v_off_ini = 3174.199 uV, v_off_fin = 3195.802 uV 18:04:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.555 uVs 18:04:10 Integrated Voltage Measurement... 18:04:19 Voltage Offset Correction: v_off_ini = 3168.798 uV, v_off_fin = 3157.183 uV 18:04:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.445 uVs 18:04:19 Integrated Voltage Measurement... 18:04:28 Voltage Offset Correction: v_off_ini = 3149.422 uV, v_off_fin = 3179.205 uV 18:04:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.456 uVs 18:04:33 I1Y Average and RMS of Measurements VT = -231.813 +- 9.679 uVs I1Y = -46.363 +- 1.936 uTm 18:04:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:04:38 Integrated Voltage Measurement... 18:04:47 Voltage Offset Correction: v_off_ini = 3216.993 uV, v_off_fin = 3195.905 uV 18:04:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -141.112 uVs 18:04:47 Integrated Voltage Measurement... 18:04:56 Voltage Offset Correction: v_off_ini = 3169.564 uV, v_off_fin = 3164.269 uV 18:04:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.275 uVs 18:04:56 Integrated Voltage Measurement... 18:05:05 Voltage Offset Correction: v_off_ini = 3189.162 uV, v_off_fin = 3197.064 uV 18:05:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -162.403 uVs 18:05:05 Integrated Voltage Measurement... 18:05:14 Voltage Offset Correction: v_off_ini = 3206.899 uV, v_off_fin = 3199.377 uV 18:05:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.020 uVs 18:05:14 Integrated Voltage Measurement... 18:05:23 Voltage Offset Correction: v_off_ini = 3205.109 uV, v_off_fin = 3182.134 uV 18:05:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -129.278 uVs 18:05:23 Integrated Voltage Measurement... 18:05:32 Voltage Offset Correction: v_off_ini = 3172.047 uV, v_off_fin = 3172.877 uV 18:05:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.922 uVs 18:05:34 I2X Average and RMS of Measurements VT = -137.668 +- 9.961 uVs I2X = 12.666 +- 0.916 uTm^2 18:05:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:05:39 Integrated Voltage Measurement... 18:05:48 Voltage Offset Correction: v_off_ini = 3175.082 uV, v_off_fin = 3192.077 uV 18:05:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.992 uVs 18:05:48 Integrated Voltage Measurement... 18:05:57 Voltage Offset Correction: v_off_ini = 3186.995 uV, v_off_fin = 3185.462 uV 18:05:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.930 uVs 18:05:57 Integrated Voltage Measurement... 18:06:06 Voltage Offset Correction: v_off_ini = 3194.494 uV, v_off_fin = 3179.553 uV 18:06:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.249 uVs 18:06:06 Integrated Voltage Measurement... 18:06:15 Voltage Offset Correction: v_off_ini = 3196.714 uV, v_off_fin = 3184.685 uV 18:06:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.151 uVs 18:06:15 Integrated Voltage Measurement... 18:06:24 Voltage Offset Correction: v_off_ini = 3179.650 uV, v_off_fin = 3164.472 uV 18:06:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.346 uVs 18:06:24 Integrated Voltage Measurement... 18:06:33 Voltage Offset Correction: v_off_ini = 3184.304 uV, v_off_fin = 3195.021 uV 18:06:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.488 uVs 18:06:36 I2Y Average and RMS of Measurements VT = -229.526 +- 1.465 uVs I2Y = -21.116 +- 0.135 uTm^2 18:06:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:06:44 Integrated Voltage Measurement... 18:06:53 Voltage Offset Correction: v_off_ini = 3183.162 uV, v_off_fin = 3185.355 uV 18:06:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.048 uVs 18:06:53 Integrated Voltage Measurement... 18:07:02 Voltage Offset Correction: v_off_ini = 3184.196 uV, v_off_fin = 3198.068 uV 18:07:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.321 uVs 18:07:02 Integrated Voltage Measurement... 18:07:11 Voltage Offset Correction: v_off_ini = 3163.776 uV, v_off_fin = 3146.099 uV 18:07:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.795 uVs 18:07:11 Integrated Voltage Measurement... 18:07:20 Voltage Offset Correction: v_off_ini = 3163.962 uV, v_off_fin = 3195.509 uV 18:07:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.601 uVs 18:07:20 Integrated Voltage Measurement... 18:07:29 Voltage Offset Correction: v_off_ini = 3182.815 uV, v_off_fin = 3164.281 uV 18:07:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.569 uVs 18:07:29 Integrated Voltage Measurement... 18:07:38 Voltage Offset Correction: v_off_ini = 3167.075 uV, v_off_fin = 3168.960 uV 18:07:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.261 uVs 18:07:42 I1X Average and RMS of Measurements VT = -143.932 +- 8.449 uVs I1X = 28.786 +- 1.690 uTm 18:07:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:07:49 Integrated Voltage Measurement... 18:07:58 Voltage Offset Correction: v_off_ini = 3160.810 uV, v_off_fin = 3146.265 uV 18:07:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.761 uVs 18:07:58 Integrated Voltage Measurement... 18:08:07 Voltage Offset Correction: v_off_ini = 3150.006 uV, v_off_fin = 3145.744 uV 18:08:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.684 uVs 18:08:07 Integrated Voltage Measurement... 18:08:16 Voltage Offset Correction: v_off_ini = 3156.123 uV, v_off_fin = 3124.312 uV 18:08:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.080 uVs 18:08:16 Integrated Voltage Measurement... 18:08:25 Voltage Offset Correction: v_off_ini = 3187.750 uV, v_off_fin = 3190.642 uV 18:08:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.111 uVs 18:08:25 Integrated Voltage Measurement... 18:08:34 Voltage Offset Correction: v_off_ini = 3112.182 uV, v_off_fin = 3121.123 uV 18:08:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.375 uVs 18:08:34 Integrated Voltage Measurement... 18:08:43 Voltage Offset Correction: v_off_ini = 3138.871 uV, v_off_fin = 3151.186 uV 18:08:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.202 uVs 18:08:47 I1Y Average and RMS of Measurements VT = -228.536 +- 10.527 uVs I1Y = -45.708 +- 2.105 uTm 18:08:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:08:52 Integrated Voltage Measurement... 18:09:01 Voltage Offset Correction: v_off_ini = 3120.292 uV, v_off_fin = 3115.714 uV 18:09:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.758 uVs 18:09:01 Integrated Voltage Measurement... 18:09:10 Voltage Offset Correction: v_off_ini = 3131.685 uV, v_off_fin = 3126.754 uV 18:09:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.737 uVs 18:09:10 Integrated Voltage Measurement... 18:09:19 Voltage Offset Correction: v_off_ini = 3096.746 uV, v_off_fin = 3091.594 uV 18:09:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.099 uVs 18:09:19 Integrated Voltage Measurement... 18:09:28 Voltage Offset Correction: v_off_ini = 3090.194 uV, v_off_fin = 3121.307 uV 18:09:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.577 uVs 18:09:28 Integrated Voltage Measurement... 18:09:37 Voltage Offset Correction: v_off_ini = 3130.891 uV, v_off_fin = 3126.942 uV 18:09:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -113.326 uVs 18:09:37 Integrated Voltage Measurement... 18:09:46 Voltage Offset Correction: v_off_ini = 3109.521 uV, v_off_fin = 3119.310 uV 18:09:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.641 uVs 18:09:49 I2X Average and RMS of Measurements VT = -124.523 +- 6.586 uVs I2X = 11.456 +- 0.606 uTm^2 18:09:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:09:54 Integrated Voltage Measurement... 18:10:03 Voltage Offset Correction: v_off_ini = 3093.793 uV, v_off_fin = 3097.014 uV 18:10:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.687 uVs 18:10:03 Integrated Voltage Measurement... 18:10:12 Voltage Offset Correction: v_off_ini = 3088.714 uV, v_off_fin = 3103.191 uV 18:10:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 220.299 uVs 18:10:12 Integrated Voltage Measurement... 18:10:21 Voltage Offset Correction: v_off_ini = 3126.435 uV, v_off_fin = 3121.476 uV 18:10:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.690 uVs 18:10:21 Integrated Voltage Measurement... 18:10:30 Voltage Offset Correction: v_off_ini = 3119.850 uV, v_off_fin = 3094.693 uV 18:10:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.589 uVs 18:10:30 Integrated Voltage Measurement... 18:10:39 Voltage Offset Correction: v_off_ini = 3119.050 uV, v_off_fin = 3114.767 uV 18:10:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.463 uVs 18:10:39 Integrated Voltage Measurement... 18:10:48 Voltage Offset Correction: v_off_ini = 3106.874 uV, v_off_fin = 3082.460 uV 18:10:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.055 uVs 18:10:50 I2Y Average and RMS of Measurements VT = -240.964 +- 4.218 uVs I2Y = -22.169 +- 0.388 uTm^2 18:10:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:10:59 Integrated Voltage Measurement... 18:11:08 Voltage Offset Correction: v_off_ini = 3114.052 uV, v_off_fin = 3093.390 uV 18:11:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -184.737 uVs 18:11:08 Integrated Voltage Measurement... 18:11:17 Voltage Offset Correction: v_off_ini = 3087.872 uV, v_off_fin = 3105.359 uV 18:11:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.430 uVs 18:11:17 Integrated Voltage Measurement... 18:11:26 Voltage Offset Correction: v_off_ini = 3067.730 uV, v_off_fin = 3052.042 uV 18:11:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -163.177 uVs 18:11:26 Integrated Voltage Measurement... 18:11:35 Voltage Offset Correction: v_off_ini = 3068.855 uV, v_off_fin = 3075.110 uV 18:11:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.118 uVs 18:11:35 Integrated Voltage Measurement... 18:11:44 Voltage Offset Correction: v_off_ini = 3069.625 uV, v_off_fin = 3080.415 uV 18:11:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.462 uVs 18:11:44 Integrated Voltage Measurement... 18:11:53 Voltage Offset Correction: v_off_ini = 3093.814 uV, v_off_fin = 3074.696 uV 18:11:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.424 uVs 18:11:57 I1X Average and RMS of Measurements VT = -159.725 +- 7.523 uVs I1X = 31.946 +- 1.505 uTm 18:11:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:12:04 Integrated Voltage Measurement... 18:12:13 Voltage Offset Correction: v_off_ini = 3092.262 uV, v_off_fin = 3087.328 uV 18:12:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.872 uVs 18:12:13 Integrated Voltage Measurement... 18:12:22 Voltage Offset Correction: v_off_ini = 3088.558 uV, v_off_fin = 3080.437 uV 18:12:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 198.991 uVs 18:12:22 Integrated Voltage Measurement... 18:12:31 Voltage Offset Correction: v_off_ini = 3076.736 uV, v_off_fin = 3072.027 uV 18:12:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.973 uVs 18:12:31 Integrated Voltage Measurement... 18:12:40 Voltage Offset Correction: v_off_ini = 3046.235 uV, v_off_fin = 3059.863 uV 18:12:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.763 uVs 18:12:40 Integrated Voltage Measurement... 18:12:49 Voltage Offset Correction: v_off_ini = 3050.737 uV, v_off_fin = 3029.984 uV 18:12:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.799 uVs 18:12:49 Integrated Voltage Measurement... 18:12:58 Voltage Offset Correction: v_off_ini = 3049.115 uV, v_off_fin = 3062.713 uV 18:12:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.341 uVs 18:13:02 I1Y Average and RMS of Measurements VT = -229.790 +- 12.296 uVs I1Y = -45.959 +- 2.458 uTm 18:13:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:13:07 Integrated Voltage Measurement... 18:13:16 Voltage Offset Correction: v_off_ini = 3006.032 uV, v_off_fin = 2989.310 uV 18:13:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.194 uVs 18:13:16 Integrated Voltage Measurement... 18:13:25 Voltage Offset Correction: v_off_ini = 3028.202 uV, v_off_fin = 3039.785 uV 18:13:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.602 uVs 18:13:25 Integrated Voltage Measurement... 18:13:34 Voltage Offset Correction: v_off_ini = 3062.430 uV, v_off_fin = 3040.499 uV 18:13:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.475 uVs 18:13:34 Integrated Voltage Measurement... 18:13:43 Voltage Offset Correction: v_off_ini = 3020.038 uV, v_off_fin = 3031.844 uV 18:13:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.423 uVs 18:13:43 Integrated Voltage Measurement... 18:13:52 Voltage Offset Correction: v_off_ini = 3062.179 uV, v_off_fin = 3039.398 uV 18:13:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.519 uVs 18:13:52 Integrated Voltage Measurement... 18:14:01 Voltage Offset Correction: v_off_ini = 3035.694 uV, v_off_fin = 3045.775 uV 18:14:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.754 uVs 18:14:03 I2X Average and RMS of Measurements VT = -109.828 +- 3.854 uVs I2X = 10.104 +- 0.355 uTm^2 18:14:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:14:09 Integrated Voltage Measurement... 18:14:17 Voltage Offset Correction: v_off_ini = 3036.296 uV, v_off_fin = 3026.524 uV 18:14:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.941 uVs 18:14:18 Integrated Voltage Measurement... 18:14:27 Voltage Offset Correction: v_off_ini = 3052.883 uV, v_off_fin = 3055.989 uV 18:14:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.794 uVs 18:14:27 Integrated Voltage Measurement... 18:14:36 Voltage Offset Correction: v_off_ini = 3061.394 uV, v_off_fin = 3057.550 uV 18:14:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.717 uVs 18:14:36 Integrated Voltage Measurement... 18:14:45 Voltage Offset Correction: v_off_ini = 3052.541 uV, v_off_fin = 3062.233 uV 18:14:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.032 uVs 18:14:45 Integrated Voltage Measurement... 18:14:54 Voltage Offset Correction: v_off_ini = 3057.952 uV, v_off_fin = 3047.680 uV 18:14:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.255 uVs 18:14:54 Integrated Voltage Measurement... 18:15:03 Voltage Offset Correction: v_off_ini = 3034.324 uV, v_off_fin = 3052.177 uV 18:15:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.635 uVs 18:15:05 I2Y Average and RMS of Measurements VT = -232.229 +- 5.979 uVs I2Y = -21.365 +- 0.550 uTm^2 18:15:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:15:13 Integrated Voltage Measurement... 18:15:22 Voltage Offset Correction: v_off_ini = 3065.114 uV, v_off_fin = 3063.275 uV 18:15:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -140.150 uVs 18:15:22 Integrated Voltage Measurement... 18:15:31 Voltage Offset Correction: v_off_ini = 3072.394 uV, v_off_fin = 3056.839 uV 18:15:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.004 uVs 18:15:31 Integrated Voltage Measurement... 18:15:40 Voltage Offset Correction: v_off_ini = 3045.208 uV, v_off_fin = 3076.627 uV 18:15:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.465 uVs 18:15:40 Integrated Voltage Measurement... 18:15:49 Voltage Offset Correction: v_off_ini = 3095.633 uV, v_off_fin = 3111.486 uV 18:15:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 179.253 uVs 18:15:49 Integrated Voltage Measurement... 18:15:58 Voltage Offset Correction: v_off_ini = 3083.571 uV, v_off_fin = 3094.024 uV 18:15:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -146.613 uVs 18:15:58 Integrated Voltage Measurement... 18:16:07 Voltage Offset Correction: v_off_ini = 3092.770 uV, v_off_fin = 3107.180 uV 18:16:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.619 uVs 18:16:12 I1X Average and RMS of Measurements VT = -150.184 +- 3.505 uVs I1X = 30.038 +- 0.701 uTm 18:16:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:16:18 Integrated Voltage Measurement... 18:16:27 Voltage Offset Correction: v_off_ini = 3080.074 uV, v_off_fin = 3053.242 uV 18:16:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.793 uVs 18:16:27 Integrated Voltage Measurement... 18:16:36 Voltage Offset Correction: v_off_ini = 3046.251 uV, v_off_fin = 3034.863 uV 18:16:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.563 uVs 18:16:36 Integrated Voltage Measurement... 18:16:45 Voltage Offset Correction: v_off_ini = 3034.874 uV, v_off_fin = 3051.907 uV 18:16:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.561 uVs 18:16:45 Integrated Voltage Measurement... 18:16:54 Voltage Offset Correction: v_off_ini = 3050.614 uV, v_off_fin = 3062.019 uV 18:16:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.742 uVs 18:16:54 Integrated Voltage Measurement... 18:17:03 Voltage Offset Correction: v_off_ini = 3056.621 uV, v_off_fin = 3026.900 uV 18:17:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.308 uVs 18:17:03 Integrated Voltage Measurement... 18:17:12 Voltage Offset Correction: v_off_ini = 3023.551 uV, v_off_fin = 3046.042 uV 18:17:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.606 uVs 18:17:16 I1Y Average and RMS of Measurements VT = -242.596 +- 5.705 uVs I1Y = -48.519 +- 1.141 uTm 18:17:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:17:22 Integrated Voltage Measurement... 18:17:30 Voltage Offset Correction: v_off_ini = 3027.842 uV, v_off_fin = 3031.219 uV 18:17:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.023 uVs 18:17:31 Integrated Voltage Measurement... 18:17:40 Voltage Offset Correction: v_off_ini = 3035.256 uV, v_off_fin = 3030.350 uV 18:17:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.315 uVs 18:17:40 Integrated Voltage Measurement... 18:17:49 Voltage Offset Correction: v_off_ini = 3027.424 uV, v_off_fin = 2994.010 uV 18:17:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.854 uVs 18:17:49 Integrated Voltage Measurement... 18:17:58 Voltage Offset Correction: v_off_ini = 3037.550 uV, v_off_fin = 3034.709 uV 18:17:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.967 uVs 18:17:58 Integrated Voltage Measurement... 18:18:07 Voltage Offset Correction: v_off_ini = 3039.685 uV, v_off_fin = 3024.870 uV 18:18:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.764 uVs 18:18:07 Integrated Voltage Measurement... 18:18:16 Voltage Offset Correction: v_off_ini = 3033.418 uV, v_off_fin = 3009.946 uV 18:18:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.722 uVs 18:18:18 I2X Average and RMS of Measurements VT = -111.774 +- 3.393 uVs I2X = 10.283 +- 0.312 uTm^2 18:18:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:18:23 Integrated Voltage Measurement... 18:18:32 Voltage Offset Correction: v_off_ini = 2985.829 uV, v_off_fin = 3016.529 uV 18:18:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.817 uVs 18:18:32 Integrated Voltage Measurement... 18:18:41 Voltage Offset Correction: v_off_ini = 3029.554 uV, v_off_fin = 3015.614 uV 18:18:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.880 uVs 18:18:41 Integrated Voltage Measurement... 18:18:50 Voltage Offset Correction: v_off_ini = 2981.712 uV, v_off_fin = 2982.964 uV 18:18:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.978 uVs 18:18:50 Integrated Voltage Measurement... 18:18:59 Voltage Offset Correction: v_off_ini = 3004.637 uV, v_off_fin = 3016.028 uV 18:18:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.689 uVs 18:18:59 Integrated Voltage Measurement... 18:19:08 Voltage Offset Correction: v_off_ini = 2977.963 uV, v_off_fin = 2968.955 uV 18:19:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.183 uVs 18:19:08 Integrated Voltage Measurement... 18:19:17 Voltage Offset Correction: v_off_ini = 3004.204 uV, v_off_fin = 3006.196 uV 18:19:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.480 uVs 18:19:20 I2Y Average and RMS of Measurements VT = -239.505 +- 8.411 uVs I2Y = -22.034 +- 0.774 uTm^2 18:19:24 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:19:28 Integrated Voltage Measurement... 18:19:37 Voltage Offset Correction: v_off_ini = 2992.884 uV, v_off_fin = 2988.852 uV 18:19:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.968 uVs 18:19:37 Integrated Voltage Measurement... 18:19:46 Voltage Offset Correction: v_off_ini = 2994.522 uV, v_off_fin = 3020.645 uV 18:19:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.093 uVs 18:19:46 Integrated Voltage Measurement... 18:19:55 Voltage Offset Correction: v_off_ini = 3039.118 uV, v_off_fin = 3018.798 uV 18:19:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.631 uVs 18:19:55 Integrated Voltage Measurement... 18:20:04 Voltage Offset Correction: v_off_ini = 3009.897 uV, v_off_fin = 3024.422 uV 18:20:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.218 uVs 18:20:04 Integrated Voltage Measurement... 18:20:13 Voltage Offset Correction: v_off_ini = 3003.510 uV, v_off_fin = 3008.213 uV 18:20:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.214 uVs 18:20:13 Integrated Voltage Measurement... 18:20:22 Voltage Offset Correction: v_off_ini = 3018.777 uV, v_off_fin = 3025.437 uV 18:20:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 129.370 uVs 18:20:26 I1X Average and RMS of Measurements VT = -113.082 +- 5.151 uVs I1X = 22.617 +- 1.031 uTm 18:20:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:20:33 Integrated Voltage Measurement... 18:20:42 Voltage Offset Correction: v_off_ini = 3029.185 uV, v_off_fin = 3023.412 uV 18:20:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.357 uVs 18:20:42 Integrated Voltage Measurement... 18:20:51 Voltage Offset Correction: v_off_ini = 3020.712 uV, v_off_fin = 3037.170 uV 18:20:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.407 uVs 18:20:51 Integrated Voltage Measurement... 18:21:00 Voltage Offset Correction: v_off_ini = 3037.274 uV, v_off_fin = 3023.588 uV 18:21:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.350 uVs 18:21:00 Integrated Voltage Measurement... 18:21:09 Voltage Offset Correction: v_off_ini = 3011.424 uV, v_off_fin = 3018.915 uV 18:21:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.076 uVs 18:21:09 Integrated Voltage Measurement... 18:21:18 Voltage Offset Correction: v_off_ini = 3029.790 uV, v_off_fin = 3017.898 uV 18:21:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.337 uVs 18:21:18 Integrated Voltage Measurement... 18:21:27 Voltage Offset Correction: v_off_ini = 3010.963 uV, v_off_fin = 3056.751 uV 18:21:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.193 uVs 18:21:31 I1Y Average and RMS of Measurements VT = -237.620 +- 4.553 uVs I1Y = -47.524 +- 0.911 uTm 18:21:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:21:36 Integrated Voltage Measurement... 18:21:45 Voltage Offset Correction: v_off_ini = 3032.817 uV, v_off_fin = 3039.821 uV 18:21:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.545 uVs 18:21:45 Integrated Voltage Measurement... 18:21:54 Voltage Offset Correction: v_off_ini = 3028.371 uV, v_off_fin = 3003.210 uV 18:21:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.064 uVs 18:21:54 Integrated Voltage Measurement... 18:22:03 Voltage Offset Correction: v_off_ini = 2992.966 uV, v_off_fin = 2992.269 uV 18:22:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.928 uVs 18:22:03 Integrated Voltage Measurement... 18:22:12 Voltage Offset Correction: v_off_ini = 3008.563 uV, v_off_fin = 3002.924 uV 18:22:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.491 uVs 18:22:12 Integrated Voltage Measurement... 18:22:21 Voltage Offset Correction: v_off_ini = 3022.348 uV, v_off_fin = 2995.417 uV 18:22:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.540 uVs 18:22:21 Integrated Voltage Measurement... 18:22:30 Voltage Offset Correction: v_off_ini = 3031.408 uV, v_off_fin = 3054.327 uV 18:22:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.920 uVs 18:22:33 I2X Average and RMS of Measurements VT = -87.081 +- 4.137 uVs I2X = 8.011 +- 0.381 uTm^2 18:22:35 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:22:38 Integrated Voltage Measurement... 18:22:47 Voltage Offset Correction: v_off_ini = 3001.655 uV, v_off_fin = 3027.263 uV 18:22:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.229 uVs 18:22:47 Integrated Voltage Measurement... 18:22:56 Voltage Offset Correction: v_off_ini = 3024.313 uV, v_off_fin = 3016.836 uV 18:22:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.878 uVs 18:22:56 Integrated Voltage Measurement... 18:23:05 Voltage Offset Correction: v_off_ini = 3040.597 uV, v_off_fin = 3037.733 uV 18:23:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.316 uVs 18:23:05 Integrated Voltage Measurement... 18:23:14 Voltage Offset Correction: v_off_ini = 3033.686 uV, v_off_fin = 3021.498 uV 18:23:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.389 uVs 18:23:14 Integrated Voltage Measurement... 18:23:23 Voltage Offset Correction: v_off_ini = 3006.956 uV, v_off_fin = 3012.134 uV 18:23:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.519 uVs 18:23:23 Integrated Voltage Measurement... 18:23:32 Voltage Offset Correction: v_off_ini = 3020.795 uV, v_off_fin = 3038.729 uV 18:23:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.742 uVs 18:23:34 I2Y Average and RMS of Measurements VT = -235.346 +- 5.535 uVs I2Y = -21.652 +- 0.509 uTm^2 18:23:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:23:56 Integrated Voltage Measurement... 18:24:05 Voltage Offset Correction: v_off_ini = 3033.092 uV, v_off_fin = 3039.702 uV 18:24:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.312 uVs 18:24:05 Integrated Voltage Measurement... 18:24:14 Voltage Offset Correction: v_off_ini = 3042.357 uV, v_off_fin = 3056.982 uV 18:24:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 178.158 uVs 18:24:14 Integrated Voltage Measurement... 18:24:23 Voltage Offset Correction: v_off_ini = 3071.355 uV, v_off_fin = 3085.460 uV 18:24:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.347 uVs 18:24:23 Integrated Voltage Measurement... 18:24:32 Voltage Offset Correction: v_off_ini = 3098.148 uV, v_off_fin = 3085.648 uV 18:24:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.274 uVs 18:24:32 Integrated Voltage Measurement... 18:24:41 Voltage Offset Correction: v_off_ini = 3083.233 uV, v_off_fin = 3090.945 uV 18:24:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.998 uVs 18:24:41 Integrated Voltage Measurement... 18:24:50 Voltage Offset Correction: v_off_ini = 3071.533 uV, v_off_fin = 3053.510 uV 18:24:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 197.710 uVs 18:24:54 I1X Average and RMS of Measurements VT = -167.133 +- 11.789 uVs I1X = 33.427 +- 2.358 uTm 18:24:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:25:00 Integrated Voltage Measurement... 18:25:09 Voltage Offset Correction: v_off_ini = 3063.953 uV, v_off_fin = 3077.255 uV 18:25:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.846 uVs 18:25:09 Integrated Voltage Measurement... 18:25:18 Voltage Offset Correction: v_off_ini = 3092.694 uV, v_off_fin = 3105.737 uV 18:25:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.907 uVs 18:25:18 Integrated Voltage Measurement... 18:25:27 Voltage Offset Correction: v_off_ini = 3108.805 uV, v_off_fin = 3106.419 uV 18:25:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.189 uVs 18:25:27 Integrated Voltage Measurement... 18:25:36 Voltage Offset Correction: v_off_ini = 3089.622 uV, v_off_fin = 3116.895 uV 18:25:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.000 uVs 18:25:36 Integrated Voltage Measurement... 18:25:45 Voltage Offset Correction: v_off_ini = 3096.668 uV, v_off_fin = 3078.730 uV 18:25:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.148 uVs 18:25:45 Integrated Voltage Measurement... 18:25:54 Voltage Offset Correction: v_off_ini = 3091.788 uV, v_off_fin = 3106.348 uV 18:25:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.423 uVs 18:25:59 I1Y Average and RMS of Measurements VT = -177.252 +- 3.356 uVs I1Y = -35.450 +- 0.671 uTm 18:26:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:26:06 Integrated Voltage Measurement... 18:26:15 Voltage Offset Correction: v_off_ini = 3133.040 uV, v_off_fin = 3123.989 uV 18:26:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.756 uVs 18:26:15 Integrated Voltage Measurement... 18:26:24 Voltage Offset Correction: v_off_ini = 3116.911 uV, v_off_fin = 3122.143 uV 18:26:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.714 uVs 18:26:24 Integrated Voltage Measurement... 18:26:33 Voltage Offset Correction: v_off_ini = 3116.988 uV, v_off_fin = 3091.645 uV 18:26:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -134.521 uVs 18:26:33 Integrated Voltage Measurement... 18:26:42 Voltage Offset Correction: v_off_ini = 3135.754 uV, v_off_fin = 3132.203 uV 18:26:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.424 uVs 18:26:42 Integrated Voltage Measurement... 18:26:51 Voltage Offset Correction: v_off_ini = 3112.647 uV, v_off_fin = 3093.511 uV 18:26:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -148.561 uVs 18:26:51 Integrated Voltage Measurement... 18:27:00 Voltage Offset Correction: v_off_ini = 3115.937 uV, v_off_fin = 3125.530 uV 18:27:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.436 uVs 18:27:03 I2X Average and RMS of Measurements VT = -126.902 +- 4.407 uVs I2X = 11.675 +- 0.406 uTm^2 18:27:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:27:10 Integrated Voltage Measurement... 18:27:19 Voltage Offset Correction: v_off_ini = 3117.184 uV, v_off_fin = 3109.895 uV 18:27:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.370 uVs 18:27:19 Integrated Voltage Measurement... 18:27:28 Voltage Offset Correction: v_off_ini = 3121.252 uV, v_off_fin = 3111.022 uV 18:27:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 169.202 uVs 18:27:28 Integrated Voltage Measurement... 18:27:37 Voltage Offset Correction: v_off_ini = 3130.112 uV, v_off_fin = 3124.717 uV 18:27:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.435 uVs 18:27:37 Integrated Voltage Measurement... 18:27:46 Voltage Offset Correction: v_off_ini = 3113.801 uV, v_off_fin = 3104.653 uV 18:27:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.547 uVs 18:27:46 Integrated Voltage Measurement... 18:27:55 Voltage Offset Correction: v_off_ini = 3099.548 uV, v_off_fin = 3121.319 uV 18:27:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.037 uVs 18:27:55 Integrated Voltage Measurement... 18:28:04 Voltage Offset Correction: v_off_ini = 3098.664 uV, v_off_fin = 3114.508 uV 18:28:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.490 uVs 18:28:07 I2Y Average and RMS of Measurements VT = -174.014 +- 10.346 uVs I2Y = -16.010 +- 0.952 uTm^2 18:28:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:28:16 Integrated Voltage Measurement... 18:28:25 Voltage Offset Correction: v_off_ini = 3114.323 uV, v_off_fin = 3118.139 uV 18:28:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.973 uVs 18:28:25 Integrated Voltage Measurement... 18:28:34 Voltage Offset Correction: v_off_ini = 3140.851 uV, v_off_fin = 3086.448 uV 18:28:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.149 uVs 18:28:34 Integrated Voltage Measurement... 18:28:43 Voltage Offset Correction: v_off_ini = 3118.571 uV, v_off_fin = 3137.260 uV 18:28:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.882 uVs 18:28:43 Integrated Voltage Measurement... 18:28:52 Voltage Offset Correction: v_off_ini = 3120.747 uV, v_off_fin = 3131.885 uV 18:28:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.505 uVs 18:28:52 Integrated Voltage Measurement... 18:29:01 Voltage Offset Correction: v_off_ini = 3128.705 uV, v_off_fin = 3106.374 uV 18:29:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -164.575 uVs 18:29:01 Integrated Voltage Measurement... 18:29:10 Voltage Offset Correction: v_off_ini = 3115.316 uV, v_off_fin = 3148.300 uV 18:29:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.264 uVs 18:29:14 I1X Average and RMS of Measurements VT = -152.891 +- 19.575 uVs I1X = 30.579 +- 3.915 uTm 18:29:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:29:20 Integrated Voltage Measurement... 18:29:29 Voltage Offset Correction: v_off_ini = 3101.127 uV, v_off_fin = 3094.891 uV 18:29:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.394 uVs 18:29:29 Integrated Voltage Measurement... 18:29:38 Voltage Offset Correction: v_off_ini = 3120.305 uV, v_off_fin = 3163.135 uV 18:29:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.509 uVs 18:29:38 Integrated Voltage Measurement... 18:29:47 Voltage Offset Correction: v_off_ini = 3146.313 uV, v_off_fin = 3126.997 uV 18:29:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.210 uVs 18:29:47 Integrated Voltage Measurement... 18:29:56 Voltage Offset Correction: v_off_ini = 3134.093 uV, v_off_fin = 3141.851 uV 18:29:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.698 uVs 18:29:56 Integrated Voltage Measurement... 18:30:05 Voltage Offset Correction: v_off_ini = 3137.139 uV, v_off_fin = 3104.867 uV 18:30:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.200 uVs 18:30:05 Integrated Voltage Measurement... 18:30:14 Voltage Offset Correction: v_off_ini = 3121.446 uV, v_off_fin = 3135.497 uV 18:30:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.398 uVs 18:30:18 I1Y Average and RMS of Measurements VT = -206.901 +- 4.486 uVs I1Y = -41.380 +- 0.897 uTm 18:30:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:30:26 Integrated Voltage Measurement... 18:30:35 Voltage Offset Correction: v_off_ini = 3161.991 uV, v_off_fin = 3148.583 uV 18:30:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -137.373 uVs 18:30:35 Integrated Voltage Measurement... 18:30:44 Voltage Offset Correction: v_off_ini = 3146.579 uV, v_off_fin = 3151.663 uV 18:30:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.276 uVs 18:30:44 Integrated Voltage Measurement... 18:30:53 Voltage Offset Correction: v_off_ini = 3116.513 uV, v_off_fin = 3122.229 uV 18:30:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.072 uVs 18:30:53 Integrated Voltage Measurement... 18:31:02 Voltage Offset Correction: v_off_ini = 3159.220 uV, v_off_fin = 3162.838 uV 18:31:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.956 uVs 18:31:02 Integrated Voltage Measurement... 18:31:11 Voltage Offset Correction: v_off_ini = 3142.158 uV, v_off_fin = 3131.229 uV 18:31:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.738 uVs 18:31:11 Integrated Voltage Measurement... 18:31:20 Voltage Offset Correction: v_off_ini = 3124.242 uV, v_off_fin = 3122.712 uV 18:31:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.871 uVs 18:31:23 I2X Average and RMS of Measurements VT = -124.214 +- 5.324 uVs I2X = 11.428 +- 0.490 uTm^2 18:31:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:31:30 Integrated Voltage Measurement... 18:31:39 Voltage Offset Correction: v_off_ini = 3111.223 uV, v_off_fin = 3085.667 uV 18:31:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.977 uVs 18:31:39 Integrated Voltage Measurement... 18:31:48 Voltage Offset Correction: v_off_ini = 3129.273 uV, v_off_fin = 3125.858 uV 18:31:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.547 uVs 18:31:48 Integrated Voltage Measurement... 18:31:57 Voltage Offset Correction: v_off_ini = 3113.178 uV, v_off_fin = 3120.535 uV 18:31:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.552 uVs 18:31:57 Integrated Voltage Measurement... 18:32:06 Voltage Offset Correction: v_off_ini = 3138.985 uV, v_off_fin = 3121.451 uV 18:32:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.276 uVs 18:32:06 Integrated Voltage Measurement... 18:32:15 Voltage Offset Correction: v_off_ini = 3122.565 uV, v_off_fin = 3109.955 uV 18:32:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.750 uVs 18:32:15 Integrated Voltage Measurement... 18:32:24 Voltage Offset Correction: v_off_ini = 3113.538 uV, v_off_fin = 3112.041 uV 18:32:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.617 uVs 18:32:27 I2Y Average and RMS of Measurements VT = -195.120 +- 5.305 uVs I2Y = -17.951 +- 0.488 uTm^2 18:32:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:32:36 Integrated Voltage Measurement... 18:32:45 Voltage Offset Correction: v_off_ini = 3139.461 uV, v_off_fin = 3149.692 uV 18:32:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.700 uVs 18:32:45 Integrated Voltage Measurement... 18:32:53 Voltage Offset Correction: v_off_ini = 3140.044 uV, v_off_fin = 3147.564 uV 18:32:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.385 uVs 18:32:54 Integrated Voltage Measurement... 18:33:02 Voltage Offset Correction: v_off_ini = 3138.249 uV, v_off_fin = 3127.470 uV 18:33:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -194.826 uVs 18:33:03 Integrated Voltage Measurement... 18:33:11 Voltage Offset Correction: v_off_ini = 3133.402 uV, v_off_fin = 3125.116 uV 18:33:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.331 uVs 18:33:12 Integrated Voltage Measurement... 18:33:20 Voltage Offset Correction: v_off_ini = 3137.750 uV, v_off_fin = 3125.356 uV 18:33:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.242 uVs 18:33:21 Integrated Voltage Measurement... 18:33:29 Voltage Offset Correction: v_off_ini = 3126.076 uV, v_off_fin = 3129.084 uV 18:33:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 163.621 uVs 18:33:34 I1X Average and RMS of Measurements VT = -161.684 +- 10.560 uVs I1X = 32.337 +- 2.112 uTm 18:33:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:33:40 Integrated Voltage Measurement... 18:33:49 Voltage Offset Correction: v_off_ini = 3105.647 uV, v_off_fin = 3091.650 uV 18:33:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.208 uVs 18:33:49 Integrated Voltage Measurement... 18:33:58 Voltage Offset Correction: v_off_ini = 3140.579 uV, v_off_fin = 3149.269 uV 18:33:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.552 uVs 18:33:58 Integrated Voltage Measurement... 18:34:07 Voltage Offset Correction: v_off_ini = 3117.254 uV, v_off_fin = 3097.301 uV 18:34:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.733 uVs 18:34:07 Integrated Voltage Measurement... 18:34:16 Voltage Offset Correction: v_off_ini = 3098.555 uV, v_off_fin = 3084.864 uV 18:34:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.671 uVs 18:34:16 Integrated Voltage Measurement... 18:34:25 Voltage Offset Correction: v_off_ini = 3107.374 uV, v_off_fin = 3114.654 uV 18:34:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.850 uVs 18:34:25 Integrated Voltage Measurement... 18:34:34 Voltage Offset Correction: v_off_ini = 3127.213 uV, v_off_fin = 3136.079 uV 18:34:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.404 uVs 18:34:38 I1Y Average and RMS of Measurements VT = -217.403 +- 0.371 uVs I1Y = -43.481 +- 0.074 uTm 18:34:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:34:46 Integrated Voltage Measurement... 18:34:55 Voltage Offset Correction: v_off_ini = 3155.702 uV, v_off_fin = 3156.884 uV 18:34:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -135.740 uVs 18:34:55 Integrated Voltage Measurement... 18:35:04 Voltage Offset Correction: v_off_ini = 3155.515 uV, v_off_fin = 3180.691 uV 18:35:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.378 uVs 18:35:04 Integrated Voltage Measurement... 18:35:13 Voltage Offset Correction: v_off_ini = 3184.058 uV, v_off_fin = 3162.772 uV 18:35:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -158.548 uVs 18:35:13 Integrated Voltage Measurement... 18:35:22 Voltage Offset Correction: v_off_ini = 3167.026 uV, v_off_fin = 3151.664 uV 18:35:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 137.069 uVs 18:35:22 Integrated Voltage Measurement... 18:35:31 Voltage Offset Correction: v_off_ini = 3180.399 uV, v_off_fin = 3161.748 uV 18:35:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -135.157 uVs 18:35:31 Integrated Voltage Measurement... 18:35:40 Voltage Offset Correction: v_off_ini = 3154.154 uV, v_off_fin = 3172.559 uV 18:35:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.119 uVs 18:35:43 I2X Average and RMS of Measurements VT = -135.002 +- 9.142 uVs I2X = 12.421 +- 0.842 uTm^2 18:35:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:35:50 Integrated Voltage Measurement... 18:35:59 Voltage Offset Correction: v_off_ini = 3174.285 uV, v_off_fin = 3163.476 uV 18:35:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.028 uVs 18:35:59 Integrated Voltage Measurement... 18:36:08 Voltage Offset Correction: v_off_ini = 3158.474 uV, v_off_fin = 3190.595 uV 18:36:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.585 uVs 18:36:08 Integrated Voltage Measurement... 18:36:17 Voltage Offset Correction: v_off_ini = 3145.759 uV, v_off_fin = 3151.271 uV 18:36:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.044 uVs 18:36:17 Integrated Voltage Measurement... 18:36:26 Voltage Offset Correction: v_off_ini = 3148.823 uV, v_off_fin = 3185.565 uV 18:36:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.408 uVs 18:36:27 Integrated Voltage Measurement... 18:36:35 Voltage Offset Correction: v_off_ini = 3195.523 uV, v_off_fin = 3179.447 uV 18:36:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.093 uVs 18:36:36 Integrated Voltage Measurement... 18:36:45 Voltage Offset Correction: v_off_ini = 3157.811 uV, v_off_fin = 3174.281 uV 18:36:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.165 uVs 18:36:47 I2Y Average and RMS of Measurements VT = -225.887 +- 17.633 uVs I2Y = -20.782 +- 1.622 uTm^2 18:36:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:36:56 Integrated Voltage Measurement... 18:37:05 Voltage Offset Correction: v_off_ini = 3193.775 uV, v_off_fin = 3170.060 uV 18:37:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -173.173 uVs 18:37:05 Integrated Voltage Measurement... 18:37:14 Voltage Offset Correction: v_off_ini = 3162.785 uV, v_off_fin = 3160.849 uV 18:37:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.980 uVs 18:37:14 Integrated Voltage Measurement... 18:37:23 Voltage Offset Correction: v_off_ini = 3141.166 uV, v_off_fin = 3153.219 uV 18:37:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -170.325 uVs 18:37:23 Integrated Voltage Measurement... 18:37:32 Voltage Offset Correction: v_off_ini = 3206.293 uV, v_off_fin = 3195.218 uV 18:37:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 181.009 uVs 18:37:32 Integrated Voltage Measurement... 18:37:41 Voltage Offset Correction: v_off_ini = 3183.493 uV, v_off_fin = 3203.460 uV 18:37:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -203.346 uVs 18:37:41 Integrated Voltage Measurement... 18:37:50 Voltage Offset Correction: v_off_ini = 3194.300 uV, v_off_fin = 3238.150 uV 18:37:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.982 uVs 18:37:54 I1X Average and RMS of Measurements VT = -184.303 +- 7.365 uVs I1X = 36.862 +- 1.472 uTm 18:37:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:38:01 Integrated Voltage Measurement... 18:38:10 Voltage Offset Correction: v_off_ini = 3170.927 uV, v_off_fin = 3147.296 uV 18:38:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.123 uVs 18:38:10 Integrated Voltage Measurement... 18:38:19 Voltage Offset Correction: v_off_ini = 3157.646 uV, v_off_fin = 3185.567 uV 18:38:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.731 uVs 18:38:19 Integrated Voltage Measurement... 18:38:28 Voltage Offset Correction: v_off_ini = 3169.472 uV, v_off_fin = 3165.799 uV 18:38:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.836 uVs 18:38:28 Integrated Voltage Measurement... 18:38:37 Voltage Offset Correction: v_off_ini = 3164.224 uV, v_off_fin = 3193.003 uV 18:38:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.593 uVs 18:38:37 Integrated Voltage Measurement... 18:38:46 Voltage Offset Correction: v_off_ini = 3175.893 uV, v_off_fin = 3156.913 uV 18:38:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.638 uVs 18:38:46 Integrated Voltage Measurement... 18:38:55 Voltage Offset Correction: v_off_ini = 3180.840 uV, v_off_fin = 3183.958 uV 18:38:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.204 uVs 18:38:59 I1Y Average and RMS of Measurements VT = -224.187 +- 18.197 uVs I1Y = -44.837 +- 3.639 uTm 18:39:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:39:07 Integrated Voltage Measurement... 18:39:16 Voltage Offset Correction: v_off_ini = 3202.141 uV, v_off_fin = 3186.152 uV 18:39:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -125.453 uVs 18:39:16 Integrated Voltage Measurement... 18:39:25 Voltage Offset Correction: v_off_ini = 3235.294 uV, v_off_fin = 3243.737 uV 18:39:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 144.603 uVs 18:39:25 Integrated Voltage Measurement... 18:39:34 Voltage Offset Correction: v_off_ini = 3201.434 uV, v_off_fin = 3184.635 uV 18:39:34 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -151.619 uVs 18:39:34 Integrated Voltage Measurement... 18:39:43 Voltage Offset Correction: v_off_ini = 3189.958 uV, v_off_fin = 3186.694 uV 18:39:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 139.306 uVs 18:39:43 Integrated Voltage Measurement... 18:39:52 Voltage Offset Correction: v_off_ini = 3191.284 uV, v_off_fin = 3175.678 uV 18:39:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.198 uVs 18:39:52 Integrated Voltage Measurement... 18:40:01 Voltage Offset Correction: v_off_ini = 3169.612 uV, v_off_fin = 3178.992 uV 18:40:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.852 uVs 18:40:03 I2X Average and RMS of Measurements VT = -142.172 +- 5.057 uVs I2X = 13.081 +- 0.466 uTm^2 18:40:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:40:11 Integrated Voltage Measurement... 18:40:20 Voltage Offset Correction: v_off_ini = 3179.894 uV, v_off_fin = 3183.809 uV 18:40:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.526 uVs 18:40:20 Integrated Voltage Measurement... 18:40:29 Voltage Offset Correction: v_off_ini = 3162.652 uV, v_off_fin = 3166.989 uV 18:40:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.983 uVs 18:40:29 Integrated Voltage Measurement... 18:40:38 Voltage Offset Correction: v_off_ini = 3161.306 uV, v_off_fin = 3170.238 uV 18:40:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.490 uVs 18:40:38 Integrated Voltage Measurement... 18:40:47 Voltage Offset Correction: v_off_ini = 3167.705 uV, v_off_fin = 3146.114 uV 18:40:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.532 uVs 18:40:47 Integrated Voltage Measurement... 18:40:56 Voltage Offset Correction: v_off_ini = 3167.891 uV, v_off_fin = 3179.356 uV 18:40:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.049 uVs 18:40:56 Integrated Voltage Measurement... 18:41:05 Voltage Offset Correction: v_off_ini = 3171.318 uV, v_off_fin = 3160.624 uV 18:41:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.780 uVs 18:41:07 I2Y Average and RMS of Measurements VT = -232.227 +- 10.533 uVs I2Y = -21.365 +- 0.969 uTm^2 18:41:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:41:16 Integrated Voltage Measurement... 18:41:25 Voltage Offset Correction: v_off_ini = 3133.880 uV, v_off_fin = 3137.898 uV 18:41:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -201.266 uVs 18:41:25 Integrated Voltage Measurement... 18:41:34 Voltage Offset Correction: v_off_ini = 3166.568 uV, v_off_fin = 3178.052 uV 18:41:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 205.020 uVs 18:41:34 Integrated Voltage Measurement... 18:41:43 Voltage Offset Correction: v_off_ini = 3177.237 uV, v_off_fin = 3188.765 uV 18:41:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.644 uVs 18:41:43 Integrated Voltage Measurement... 18:41:52 Voltage Offset Correction: v_off_ini = 3191.876 uV, v_off_fin = 3190.725 uV 18:41:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 187.859 uVs 18:41:52 Integrated Voltage Measurement... 18:42:01 Voltage Offset Correction: v_off_ini = 3182.447 uV, v_off_fin = 3166.796 uV 18:42:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -180.275 uVs 18:42:01 Integrated Voltage Measurement... 18:42:10 Voltage Offset Correction: v_off_ini = 3174.836 uV, v_off_fin = 3194.591 uV 18:42:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 190.334 uVs 18:42:15 I1X Average and RMS of Measurements VT = -188.400 +- 10.994 uVs I1X = 37.682 +- 2.200 uTm 18:42:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:42:21 Integrated Voltage Measurement... 18:42:30 Voltage Offset Correction: v_off_ini = 3164.292 uV, v_off_fin = 3159.590 uV 18:42:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.408 uVs 18:42:30 Integrated Voltage Measurement... 18:42:39 Voltage Offset Correction: v_off_ini = 3138.390 uV, v_off_fin = 3161.840 uV 18:42:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.864 uVs 18:42:39 Integrated Voltage Measurement... 18:42:48 Voltage Offset Correction: v_off_ini = 3158.161 uV, v_off_fin = 3164.350 uV 18:42:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.766 uVs 18:42:48 Integrated Voltage Measurement... 18:42:57 Voltage Offset Correction: v_off_ini = 3164.616 uV, v_off_fin = 3124.988 uV 18:42:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.024 uVs 18:42:57 Integrated Voltage Measurement... 18:43:06 Voltage Offset Correction: v_off_ini = 3147.282 uV, v_off_fin = 3120.008 uV 18:43:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.117 uVs 18:43:06 Integrated Voltage Measurement... 18:43:15 Voltage Offset Correction: v_off_ini = 3145.460 uV, v_off_fin = 3131.011 uV 18:43:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.289 uVs 18:43:19 I1Y Average and RMS of Measurements VT = -237.245 +- 2.643 uVs I1Y = -47.449 +- 0.529 uTm 18:43:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:43:27 Integrated Voltage Measurement... 18:43:36 Voltage Offset Correction: v_off_ini = 3127.223 uV, v_off_fin = 3137.583 uV 18:43:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -143.488 uVs 18:43:36 Integrated Voltage Measurement... 18:43:45 Voltage Offset Correction: v_off_ini = 3132.927 uV, v_off_fin = 3152.946 uV 18:43:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.762 uVs 18:43:45 Integrated Voltage Measurement... 18:43:54 Voltage Offset Correction: v_off_ini = 3146.014 uV, v_off_fin = 3126.633 uV 18:43:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.218 uVs 18:43:54 Integrated Voltage Measurement... 18:44:03 Voltage Offset Correction: v_off_ini = 3148.828 uV, v_off_fin = 3161.529 uV 18:44:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 127.954 uVs 18:44:03 Integrated Voltage Measurement... 18:44:12 Voltage Offset Correction: v_off_ini = 3135.603 uV, v_off_fin = 3141.360 uV 18:44:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -182.225 uVs 18:44:12 Integrated Voltage Measurement... 18:44:21 Voltage Offset Correction: v_off_ini = 3145.917 uV, v_off_fin = 3177.668 uV 18:44:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.850 uVs 18:44:24 I2X Average and RMS of Measurements VT = -143.250 +- 17.573 uVs I2X = 13.179 +- 1.616 uTm^2 18:44:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:44:31 Integrated Voltage Measurement... 18:44:40 Voltage Offset Correction: v_off_ini = 3137.053 uV, v_off_fin = 3121.991 uV 18:44:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.855 uVs 18:44:40 Integrated Voltage Measurement... 18:44:49 Voltage Offset Correction: v_off_ini = 3158.947 uV, v_off_fin = 3159.499 uV 18:44:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.559 uVs 18:44:49 Integrated Voltage Measurement... 18:44:58 Voltage Offset Correction: v_off_ini = 3158.373 uV, v_off_fin = 3174.282 uV 18:44:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.814 uVs 18:44:58 Integrated Voltage Measurement... 18:45:07 Voltage Offset Correction: v_off_ini = 3171.258 uV, v_off_fin = 3151.522 uV 18:45:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.548 uVs 18:45:07 Integrated Voltage Measurement... 18:45:16 Voltage Offset Correction: v_off_ini = 3141.868 uV, v_off_fin = 3117.796 uV 18:45:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.931 uVs 18:45:16 Integrated Voltage Measurement... 18:45:25 Voltage Offset Correction: v_off_ini = 3130.362 uV, v_off_fin = 3116.213 uV 18:45:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.199 uVs 18:45:28 I2Y Average and RMS of Measurements VT = -253.818 +- 9.341 uVs I2Y = -23.351 +- 0.859 uTm^2 18:45:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:45:40 Integrated Voltage Measurement... 18:45:49 Voltage Offset Correction: v_off_ini = 3160.584 uV, v_off_fin = 3157.979 uV 18:45:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -207.443 uVs 18:45:49 Integrated Voltage Measurement... 18:45:58 Voltage Offset Correction: v_off_ini = 3139.198 uV, v_off_fin = 3134.441 uV 18:45:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.967 uVs 18:45:58 Integrated Voltage Measurement... 18:46:07 Voltage Offset Correction: v_off_ini = 3173.835 uV, v_off_fin = 3152.129 uV 18:46:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.334 uVs 18:46:07 Integrated Voltage Measurement... 18:46:16 Voltage Offset Correction: v_off_ini = 3163.907 uV, v_off_fin = 3133.031 uV 18:46:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 189.055 uVs 18:46:16 Integrated Voltage Measurement... 18:46:25 Voltage Offset Correction: v_off_ini = 3138.247 uV, v_off_fin = 3149.300 uV 18:46:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -193.234 uVs 18:46:25 Integrated Voltage Measurement... 18:46:34 Voltage Offset Correction: v_off_ini = 3139.221 uV, v_off_fin = 3134.814 uV 18:46:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.054 uVs 18:46:38 I1X Average and RMS of Measurements VT = -178.515 +- 5.835 uVs I1X = 35.704 +- 1.168 uTm 18:46:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:46:45 Integrated Voltage Measurement... 18:46:54 Voltage Offset Correction: v_off_ini = 3135.627 uV, v_off_fin = 3123.548 uV 18:46:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.130 uVs 18:46:54 Integrated Voltage Measurement... 18:47:03 Voltage Offset Correction: v_off_ini = 3150.439 uV, v_off_fin = 3166.403 uV 18:47:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.350 uVs 18:47:03 Integrated Voltage Measurement... 18:47:12 Voltage Offset Correction: v_off_ini = 3126.174 uV, v_off_fin = 3116.306 uV 18:47:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.214 uVs 18:47:12 Integrated Voltage Measurement... 18:47:21 Voltage Offset Correction: v_off_ini = 3150.630 uV, v_off_fin = 3138.193 uV 18:47:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.106 uVs 18:47:21 Integrated Voltage Measurement... 18:47:30 Voltage Offset Correction: v_off_ini = 3149.251 uV, v_off_fin = 3144.854 uV 18:47:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.241 uVs 18:47:30 Integrated Voltage Measurement... 18:47:39 Voltage Offset Correction: v_off_ini = 3142.608 uV, v_off_fin = 3159.214 uV 18:47:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.040 uVs 18:47:43 I1Y Average and RMS of Measurements VT = -219.514 +- 6.102 uVs I1Y = -43.903 +- 1.220 uTm 18:47:45 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:47:48 Integrated Voltage Measurement... 18:47:57 Voltage Offset Correction: v_off_ini = 3105.973 uV, v_off_fin = 3125.864 uV 18:47:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.571 uVs 18:47:57 Integrated Voltage Measurement... 18:48:06 Voltage Offset Correction: v_off_ini = 3143.527 uV, v_off_fin = 3128.611 uV 18:48:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 133.056 uVs 18:48:06 Integrated Voltage Measurement... 18:48:15 Voltage Offset Correction: v_off_ini = 3126.021 uV, v_off_fin = 3130.574 uV 18:48:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -140.338 uVs 18:48:15 Integrated Voltage Measurement... 18:48:24 Voltage Offset Correction: v_off_ini = 3160.934 uV, v_off_fin = 3143.778 uV 18:48:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.781 uVs 18:48:24 Integrated Voltage Measurement... 18:48:33 Voltage Offset Correction: v_off_ini = 3124.920 uV, v_off_fin = 3142.157 uV 18:48:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.266 uVs 18:48:33 Integrated Voltage Measurement... 18:48:42 Voltage Offset Correction: v_off_ini = 3173.890 uV, v_off_fin = 3166.609 uV 18:48:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.638 uVs 18:48:45 I2X Average and RMS of Measurements VT = -137.775 +- 6.900 uVs I2X = 12.676 +- 0.634 uTm^2 18:48:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:48:50 Integrated Voltage Measurement... 18:48:59 Voltage Offset Correction: v_off_ini = 3124.679 uV, v_off_fin = 3122.575 uV 18:48:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.469 uVs 18:48:59 Integrated Voltage Measurement... 18:49:08 Voltage Offset Correction: v_off_ini = 3119.442 uV, v_off_fin = 3137.084 uV 18:49:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.765 uVs 18:49:08 Integrated Voltage Measurement... 18:49:17 Voltage Offset Correction: v_off_ini = 3139.729 uV, v_off_fin = 3139.959 uV 18:49:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.553 uVs 18:49:17 Integrated Voltage Measurement... 18:49:26 Voltage Offset Correction: v_off_ini = 3138.546 uV, v_off_fin = 3136.241 uV 18:49:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.852 uVs 18:49:26 Integrated Voltage Measurement... 18:49:35 Voltage Offset Correction: v_off_ini = 3127.939 uV, v_off_fin = 3126.670 uV 18:49:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.163 uVs 18:49:35 Integrated Voltage Measurement... 18:49:44 Voltage Offset Correction: v_off_ini = 3105.444 uV, v_off_fin = 3115.854 uV 18:49:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.981 uVs 18:49:46 I2Y Average and RMS of Measurements VT = -209.797 +- 13.496 uVs I2Y = -19.301 +- 1.242 uTm^2 18:49:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:49:55 Integrated Voltage Measurement... 18:50:03 Voltage Offset Correction: v_off_ini = 3127.498 uV, v_off_fin = 3118.680 uV 18:50:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -180.609 uVs 18:50:04 Integrated Voltage Measurement... 18:50:12 Voltage Offset Correction: v_off_ini = 3097.166 uV, v_off_fin = 3107.275 uV 18:50:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 182.126 uVs 18:50:13 Integrated Voltage Measurement... 18:50:22 Voltage Offset Correction: v_off_ini = 3087.849 uV, v_off_fin = 3089.184 uV 18:50:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -151.804 uVs 18:50:22 Integrated Voltage Measurement... 18:50:31 Voltage Offset Correction: v_off_ini = 3108.560 uV, v_off_fin = 3109.873 uV 18:50:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.863 uVs 18:50:31 Integrated Voltage Measurement... 18:50:40 Voltage Offset Correction: v_off_ini = 3133.885 uV, v_off_fin = 3118.716 uV 18:50:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -192.092 uVs 18:50:40 Integrated Voltage Measurement... 18:50:49 Voltage Offset Correction: v_off_ini = 3101.384 uV, v_off_fin = 3091.192 uV 18:50:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.707 uVs 18:50:53 I1X Average and RMS of Measurements VT = -167.200 +- 12.320 uVs I1X = 33.442 +- 2.463 uTm 18:50:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:50:59 Integrated Voltage Measurement... 18:51:08 Voltage Offset Correction: v_off_ini = 3100.851 uV, v_off_fin = 3095.027 uV 18:51:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.474 uVs 18:51:08 Integrated Voltage Measurement... 18:51:17 Voltage Offset Correction: v_off_ini = 3128.351 uV, v_off_fin = 3122.081 uV 18:51:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.140 uVs 18:51:17 Integrated Voltage Measurement... 18:51:26 Voltage Offset Correction: v_off_ini = 3109.583 uV, v_off_fin = 3110.793 uV 18:51:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.512 uVs 18:51:26 Integrated Voltage Measurement... 18:51:35 Voltage Offset Correction: v_off_ini = 3105.314 uV, v_off_fin = 3141.942 uV 18:51:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.959 uVs 18:51:35 Integrated Voltage Measurement... 18:51:44 Voltage Offset Correction: v_off_ini = 3130.987 uV, v_off_fin = 3127.780 uV 18:51:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.716 uVs 18:51:44 Integrated Voltage Measurement... 18:51:53 Voltage Offset Correction: v_off_ini = 3127.280 uV, v_off_fin = 3126.065 uV 18:51:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.910 uVs 18:51:58 I1Y Average and RMS of Measurements VT = -217.285 +- 3.521 uVs I1Y = -43.457 +- 0.704 uTm 18:52:00 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:52:03 Integrated Voltage Measurement... 18:52:12 Voltage Offset Correction: v_off_ini = 3108.930 uV, v_off_fin = 3108.470 uV 18:52:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.267 uVs 18:52:12 Integrated Voltage Measurement... 18:52:21 Voltage Offset Correction: v_off_ini = 3091.602 uV, v_off_fin = 3108.110 uV 18:52:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.462 uVs 18:52:21 Integrated Voltage Measurement... 18:52:30 Voltage Offset Correction: v_off_ini = 3098.797 uV, v_off_fin = 3077.967 uV 18:52:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.765 uVs 18:52:30 Integrated Voltage Measurement... 18:52:39 Voltage Offset Correction: v_off_ini = 3085.489 uV, v_off_fin = 3104.444 uV 18:52:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.987 uVs 18:52:39 Integrated Voltage Measurement... 18:52:48 Voltage Offset Correction: v_off_ini = 3117.068 uV, v_off_fin = 3105.803 uV 18:52:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -162.502 uVs 18:52:48 Integrated Voltage Measurement... 18:52:57 Voltage Offset Correction: v_off_ini = 3145.191 uV, v_off_fin = 3144.833 uV 18:52:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.494 uVs 18:52:59 I2X Average and RMS of Measurements VT = -137.579 +- 4.572 uVs I2X = 12.657 +- 0.421 uTm^2 18:53:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:53:04 Integrated Voltage Measurement... 18:53:13 Voltage Offset Correction: v_off_ini = 3113.699 uV, v_off_fin = 3126.357 uV 18:53:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.065 uVs 18:53:13 Integrated Voltage Measurement... 18:53:22 Voltage Offset Correction: v_off_ini = 3123.434 uV, v_off_fin = 3113.941 uV 18:53:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.379 uVs 18:53:22 Integrated Voltage Measurement... 18:53:31 Voltage Offset Correction: v_off_ini = 3159.194 uV, v_off_fin = 3131.119 uV 18:53:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.834 uVs 18:53:31 Integrated Voltage Measurement... 18:53:40 Voltage Offset Correction: v_off_ini = 3160.570 uV, v_off_fin = 3135.657 uV 18:53:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.926 uVs 18:53:40 Integrated Voltage Measurement... 18:53:49 Voltage Offset Correction: v_off_ini = 3147.334 uV, v_off_fin = 3156.485 uV 18:53:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.135 uVs 18:53:49 Integrated Voltage Measurement... 18:53:58 Voltage Offset Correction: v_off_ini = 3149.239 uV, v_off_fin = 3161.955 uV 18:53:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.361 uVs 18:54:01 I2Y Average and RMS of Measurements VT = -209.117 +- 6.697 uVs I2Y = -19.239 +- 0.616 uTm^2 18:54:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:54:09 Integrated Voltage Measurement... 18:54:18 Voltage Offset Correction: v_off_ini = 3177.372 uV, v_off_fin = 3176.743 uV 18:54:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -162.438 uVs 18:54:18 Integrated Voltage Measurement... 18:54:27 Voltage Offset Correction: v_off_ini = 3173.054 uV, v_off_fin = 3175.850 uV 18:54:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 170.651 uVs 18:54:27 Integrated Voltage Measurement... 18:54:36 Voltage Offset Correction: v_off_ini = 3176.372 uV, v_off_fin = 3166.125 uV 18:54:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -176.610 uVs 18:54:36 Integrated Voltage Measurement... 18:54:45 Voltage Offset Correction: v_off_ini = 3159.983 uV, v_off_fin = 3143.776 uV 18:54:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 182.243 uVs 18:54:45 Integrated Voltage Measurement... 18:54:54 Voltage Offset Correction: v_off_ini = 3125.576 uV, v_off_fin = 3132.962 uV 18:54:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -201.617 uVs 18:54:54 Integrated Voltage Measurement... 18:55:03 Voltage Offset Correction: v_off_ini = 3155.783 uV, v_off_fin = 3126.543 uV 18:55:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 149.723 uVs 18:55:07 I1X Average and RMS of Measurements VT = -173.880 +- 5.409 uVs I1X = 34.778 +- 1.081 uTm 18:55:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:55:14 Integrated Voltage Measurement... 18:55:23 Voltage Offset Correction: v_off_ini = 3137.719 uV, v_off_fin = 3137.510 uV 18:55:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -209.839 uVs 18:55:23 Integrated Voltage Measurement... 18:55:32 Voltage Offset Correction: v_off_ini = 3168.625 uV, v_off_fin = 3167.866 uV 18:55:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.491 uVs 18:55:32 Integrated Voltage Measurement... 18:55:41 Voltage Offset Correction: v_off_ini = 3145.400 uV, v_off_fin = 3168.841 uV 18:55:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.626 uVs 18:55:41 Integrated Voltage Measurement... 18:55:50 Voltage Offset Correction: v_off_ini = 3190.606 uV, v_off_fin = 3192.988 uV 18:55:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.378 uVs 18:55:50 Integrated Voltage Measurement... 18:55:59 Voltage Offset Correction: v_off_ini = 3172.831 uV, v_off_fin = 3163.769 uV 18:55:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.175 uVs 18:55:59 Integrated Voltage Measurement... 18:56:08 Voltage Offset Correction: v_off_ini = 3171.854 uV, v_off_fin = 3168.292 uV 18:56:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.532 uVs 18:56:12 I1Y Average and RMS of Measurements VT = -219.340 +- 3.682 uVs I1Y = -43.869 +- 0.735 uTm 18:56:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:56:17 Integrated Voltage Measurement... 18:56:26 Voltage Offset Correction: v_off_ini = 3174.263 uV, v_off_fin = 3176.561 uV 18:56:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.782 uVs 18:56:26 Integrated Voltage Measurement... 18:56:35 Voltage Offset Correction: v_off_ini = 3163.782 uV, v_off_fin = 3195.400 uV 18:56:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.159 uVs 18:56:35 Integrated Voltage Measurement... 18:56:44 Voltage Offset Correction: v_off_ini = 3187.963 uV, v_off_fin = 3174.602 uV 18:56:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.564 uVs 18:56:44 Integrated Voltage Measurement... 18:56:53 Voltage Offset Correction: v_off_ini = 3173.337 uV, v_off_fin = 3176.953 uV 18:56:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.207 uVs 18:56:53 Integrated Voltage Measurement... 18:57:02 Voltage Offset Correction: v_off_ini = 3180.105 uV, v_off_fin = 3176.923 uV 18:57:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.594 uVs 18:57:02 Integrated Voltage Measurement... 18:57:11 Voltage Offset Correction: v_off_ini = 3178.943 uV, v_off_fin = 3165.288 uV 18:57:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.449 uVs 18:57:14 I2X Average and RMS of Measurements VT = -141.126 +- 1.135 uVs I2X = 12.984 +- 0.104 uTm^2 18:57:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:57:19 Integrated Voltage Measurement... 18:57:28 Voltage Offset Correction: v_off_ini = 3162.373 uV, v_off_fin = 3149.618 uV 18:57:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.948 uVs 18:57:28 Integrated Voltage Measurement... 18:57:37 Voltage Offset Correction: v_off_ini = 3154.857 uV, v_off_fin = 3172.793 uV 18:57:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.538 uVs 18:57:37 Integrated Voltage Measurement... 18:57:46 Voltage Offset Correction: v_off_ini = 3198.213 uV, v_off_fin = 3192.938 uV 18:57:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.167 uVs 18:57:46 Integrated Voltage Measurement... 18:57:55 Voltage Offset Correction: v_off_ini = 3187.266 uV, v_off_fin = 3199.585 uV 18:57:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.292 uVs 18:57:55 Integrated Voltage Measurement... 18:58:04 Voltage Offset Correction: v_off_ini = 3201.559 uV, v_off_fin = 3225.434 uV 18:58:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.904 uVs 18:58:04 Integrated Voltage Measurement... 18:58:13 Voltage Offset Correction: v_off_ini = 3204.345 uV, v_off_fin = 3205.756 uV 18:58:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.263 uVs 18:58:15 I2Y Average and RMS of Measurements VT = -219.019 +- 16.676 uVs I2Y = -20.150 +- 1.534 uTm^2 18:58:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:58:24 Integrated Voltage Measurement... 18:58:33 Voltage Offset Correction: v_off_ini = 3186.670 uV, v_off_fin = 3195.141 uV 18:58:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -158.104 uVs 18:58:33 Integrated Voltage Measurement... 18:58:42 Voltage Offset Correction: v_off_ini = 3203.900 uV, v_off_fin = 3217.143 uV 18:58:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.119 uVs 18:58:42 Integrated Voltage Measurement... 18:58:51 Voltage Offset Correction: v_off_ini = 3219.521 uV, v_off_fin = 3205.781 uV 18:58:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -193.618 uVs 18:58:51 Integrated Voltage Measurement... 18:59:00 Voltage Offset Correction: v_off_ini = 3192.607 uV, v_off_fin = 3201.646 uV 18:59:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.133 uVs 18:59:00 Integrated Voltage Measurement... 18:59:09 Voltage Offset Correction: v_off_ini = 3208.026 uV, v_off_fin = 3202.255 uV 18:59:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -163.290 uVs 18:59:09 Integrated Voltage Measurement... 18:59:18 Voltage Offset Correction: v_off_ini = 3209.606 uV, v_off_fin = 3197.507 uV 18:59:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.761 uVs 18:59:22 I1X Average and RMS of Measurements VT = -161.337 +- 8.072 uVs I1X = 32.268 +- 1.614 uTm 18:59:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:59:29 Integrated Voltage Measurement... 18:59:38 Voltage Offset Correction: v_off_ini = 3215.882 uV, v_off_fin = 3183.842 uV 18:59:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -210.050 uVs 18:59:38 Integrated Voltage Measurement... 18:59:47 Voltage Offset Correction: v_off_ini = 3172.892 uV, v_off_fin = 3188.753 uV 18:59:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.480 uVs 18:59:47 Integrated Voltage Measurement... 18:59:56 Voltage Offset Correction: v_off_ini = 3180.033 uV, v_off_fin = 3178.815 uV 18:59:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.785 uVs 18:59:56 Integrated Voltage Measurement... 19:00:05 Voltage Offset Correction: v_off_ini = 3215.053 uV, v_off_fin = 3212.614 uV 19:00:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.367 uVs 19:00:05 Integrated Voltage Measurement... 19:00:14 Voltage Offset Correction: v_off_ini = 3194.570 uV, v_off_fin = 3158.835 uV 19:00:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.260 uVs 19:00:14 Integrated Voltage Measurement... 19:00:23 Voltage Offset Correction: v_off_ini = 3158.275 uV, v_off_fin = 3198.572 uV 19:00:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.808 uVs 19:00:27 I1Y Average and RMS of Measurements VT = -217.125 +- 10.593 uVs I1Y = -43.426 +- 2.119 uTm 19:00:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:00:32 Integrated Voltage Measurement... 19:00:41 Voltage Offset Correction: v_off_ini = 3165.955 uV, v_off_fin = 3155.018 uV 19:00:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -101.597 uVs 19:00:41 Integrated Voltage Measurement... 19:00:50 Voltage Offset Correction: v_off_ini = 3150.137 uV, v_off_fin = 3150.015 uV 19:00:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 127.991 uVs 19:00:50 Integrated Voltage Measurement... 19:00:59 Voltage Offset Correction: v_off_ini = 3139.042 uV, v_off_fin = 3148.201 uV 19:00:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.293 uVs 19:00:59 Integrated Voltage Measurement... 19:01:08 Voltage Offset Correction: v_off_ini = 3180.279 uV, v_off_fin = 3176.628 uV 19:01:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.751 uVs 19:01:08 Integrated Voltage Measurement... 19:01:17 Voltage Offset Correction: v_off_ini = 3165.151 uV, v_off_fin = 3164.444 uV 19:01:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.098 uVs 19:01:17 Integrated Voltage Measurement... 19:01:26 Voltage Offset Correction: v_off_ini = 3163.009 uV, v_off_fin = 3146.004 uV 19:01:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.644 uVs 19:01:28 I2X Average and RMS of Measurements VT = -124.229 +- 12.245 uVs I2X = 11.429 +- 1.126 uTm^2 19:01:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:01:34 Integrated Voltage Measurement... 19:01:43 Voltage Offset Correction: v_off_ini = 3187.852 uV, v_off_fin = 3175.438 uV 19:01:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.517 uVs 19:01:43 Integrated Voltage Measurement... 19:01:52 Voltage Offset Correction: v_off_ini = 3165.634 uV, v_off_fin = 3165.143 uV 19:01:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.243 uVs 19:01:52 Integrated Voltage Measurement... 19:02:01 Voltage Offset Correction: v_off_ini = 3162.460 uV, v_off_fin = 3147.045 uV 19:02:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.667 uVs 19:02:01 Integrated Voltage Measurement... 19:02:10 Voltage Offset Correction: v_off_ini = 3162.521 uV, v_off_fin = 3165.867 uV 19:02:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.049 uVs 19:02:10 Integrated Voltage Measurement... 19:02:19 Voltage Offset Correction: v_off_ini = 3126.537 uV, v_off_fin = 3154.325 uV 19:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.846 uVs 19:02:19 Integrated Voltage Measurement... 19:02:28 Voltage Offset Correction: v_off_ini = 3177.252 uV, v_off_fin = 3176.475 uV 19:02:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.093 uVs 19:02:30 I2Y Average and RMS of Measurements VT = -216.236 +- 8.043 uVs I2Y = -19.894 +- 0.740 uTm^2 19:02:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:02:38 Integrated Voltage Measurement... 19:02:47 Voltage Offset Correction: v_off_ini = 3159.415 uV, v_off_fin = 3149.996 uV 19:02:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -130.336 uVs 19:02:47 Integrated Voltage Measurement... 19:02:56 Voltage Offset Correction: v_off_ini = 3128.328 uV, v_off_fin = 3167.925 uV 19:02:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.052 uVs 19:02:56 Integrated Voltage Measurement... 19:03:05 Voltage Offset Correction: v_off_ini = 3157.092 uV, v_off_fin = 3169.808 uV 19:03:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.052 uVs 19:03:05 Integrated Voltage Measurement... 19:03:14 Voltage Offset Correction: v_off_ini = 3165.839 uV, v_off_fin = 3165.990 uV 19:03:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.500 uVs 19:03:14 Integrated Voltage Measurement... 19:03:23 Voltage Offset Correction: v_off_ini = 3134.559 uV, v_off_fin = 3135.899 uV 19:03:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.305 uVs 19:03:23 Integrated Voltage Measurement... 19:03:32 Voltage Offset Correction: v_off_ini = 3141.799 uV, v_off_fin = 3133.957 uV 19:03:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.824 uVs 19:03:37 I1X Average and RMS of Measurements VT = -144.845 +- 9.118 uVs I1X = 28.969 +- 1.824 uTm 19:03:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:03:43 Integrated Voltage Measurement... 19:03:52 Voltage Offset Correction: v_off_ini = 3161.914 uV, v_off_fin = 3136.731 uV 19:03:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.036 uVs 19:03:52 Integrated Voltage Measurement... 19:04:01 Voltage Offset Correction: v_off_ini = 3164.441 uV, v_off_fin = 3166.110 uV 19:04:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.788 uVs 19:04:01 Integrated Voltage Measurement... 19:04:10 Voltage Offset Correction: v_off_ini = 3145.201 uV, v_off_fin = 3136.579 uV 19:04:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.644 uVs 19:04:10 Integrated Voltage Measurement... 19:04:19 Voltage Offset Correction: v_off_ini = 3168.217 uV, v_off_fin = 3153.455 uV 19:04:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.959 uVs 19:04:19 Integrated Voltage Measurement... 19:04:28 Voltage Offset Correction: v_off_ini = 3130.591 uV, v_off_fin = 3132.428 uV 19:04:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.745 uVs 19:04:28 Integrated Voltage Measurement... 19:04:37 Voltage Offset Correction: v_off_ini = 3171.183 uV, v_off_fin = 3173.477 uV 19:04:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.944 uVs 19:04:42 I1Y Average and RMS of Measurements VT = -226.519 +- 15.828 uVs I1Y = -45.304 +- 3.166 uTm 19:04:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:04:47 Integrated Voltage Measurement... 19:04:56 Voltage Offset Correction: v_off_ini = 3154.489 uV, v_off_fin = 3136.277 uV 19:04:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.204 uVs 19:04:56 Integrated Voltage Measurement... 19:05:05 Voltage Offset Correction: v_off_ini = 3143.026 uV, v_off_fin = 3146.111 uV 19:05:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.287 uVs 19:05:05 Integrated Voltage Measurement... 19:05:14 Voltage Offset Correction: v_off_ini = 3146.256 uV, v_off_fin = 3123.596 uV 19:05:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.541 uVs 19:05:14 Integrated Voltage Measurement... 19:05:23 Voltage Offset Correction: v_off_ini = 3133.323 uV, v_off_fin = 3144.195 uV 19:05:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.863 uVs 19:05:23 Integrated Voltage Measurement... 19:05:32 Voltage Offset Correction: v_off_ini = 3136.124 uV, v_off_fin = 3098.246 uV 19:05:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.419 uVs 19:05:32 Integrated Voltage Measurement... 19:05:41 Voltage Offset Correction: v_off_ini = 3116.593 uV, v_off_fin = 3143.573 uV 19:05:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 110.298 uVs 19:05:43 I2X Average and RMS of Measurements VT = -111.102 +- 6.569 uVs I2X = 10.222 +- 0.605 uTm^2 19:05:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:05:48 Integrated Voltage Measurement... 19:05:57 Voltage Offset Correction: v_off_ini = 3140.307 uV, v_off_fin = 3146.994 uV 19:05:57 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = -231.292 uVs 19:05:57 Integrated Voltage Measurement... 19:06:06 Voltage Offset Correction: v_off_ini = 3134.985 uV, v_off_fin = 3164.736 uV 19:06:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.370 uVs 19:06:06 Integrated Voltage Measurement... 19:06:15 Voltage Offset Correction: v_off_ini = 3142.974 uV, v_off_fin = 3127.414 uV 19:06:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.962 uVs 19:06:15 Integrated Voltage Measurement... 19:06:24 Voltage Offset Correction: v_off_ini = 3147.365 uV, v_off_fin = 3141.372 uV 19:06:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.679 uVs 19:06:25 Integrated Voltage Measurement... 19:06:33 Voltage Offset Correction: v_off_ini = 3142.362 uV, v_off_fin = 3131.221 uV 19:06:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.847 uVs 19:06:34 Integrated Voltage Measurement... 19:06:43 Voltage Offset Correction: v_off_ini = 3126.330 uV, v_off_fin = 3137.522 uV 19:06:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.777 uVs 19:06:45 I2Y Average and RMS of Measurements VT = -226.488 +- 9.280 uVs I2Y = -20.838 +- 0.855 uTm^2 19:07:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:07:06 Integrated Voltage Measurement... 19:07:15 Voltage Offset Correction: v_off_ini = 3128.909 uV, v_off_fin = 3142.654 uV 19:07:15 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -177.747 uVs 19:07:15 Integrated Voltage Measurement... 19:07:24 Voltage Offset Correction: v_off_ini = 3151.878 uV, v_off_fin = 3163.933 uV 19:07:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.732 uVs 19:07:24 Integrated Voltage Measurement... 19:07:33 Voltage Offset Correction: v_off_ini = 3137.892 uV, v_off_fin = 3117.884 uV 19:07:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -170.466 uVs 19:07:33 Integrated Voltage Measurement... 19:07:42 Voltage Offset Correction: v_off_ini = 3147.022 uV, v_off_fin = 3144.117 uV 19:07:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 194.425 uVs 19:07:42 Integrated Voltage Measurement... 19:07:51 Voltage Offset Correction: v_off_ini = 3142.873 uV, v_off_fin = 3127.075 uV 19:07:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.911 uVs 19:07:51 Integrated Voltage Measurement... 19:08:00 Voltage Offset Correction: v_off_ini = 3152.836 uV, v_off_fin = 3161.256 uV 19:08:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.544 uVs 19:08:04 I1X Average and RMS of Measurements VT = -171.804 +- 17.421 uVs I1X = 34.364 +- 3.482 uTm 19:08:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:08:11 Integrated Voltage Measurement... 19:08:20 Voltage Offset Correction: v_off_ini = 3135.211 uV, v_off_fin = 3124.199 uV 19:08:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.288 uVs 19:08:20 Integrated Voltage Measurement... 19:08:29 Voltage Offset Correction: v_off_ini = 3126.568 uV, v_off_fin = 3125.522 uV 19:08:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.517 uVs 19:08:29 Integrated Voltage Measurement... 19:08:38 Voltage Offset Correction: v_off_ini = 3112.133 uV, v_off_fin = 3103.259 uV 19:08:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.557 uVs 19:08:38 Integrated Voltage Measurement... 19:08:47 Voltage Offset Correction: v_off_ini = 3120.831 uV, v_off_fin = 3107.089 uV 19:08:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.905 uVs 19:08:47 Integrated Voltage Measurement... 19:08:56 Voltage Offset Correction: v_off_ini = 3112.532 uV, v_off_fin = 3106.827 uV 19:08:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.792 uVs 19:08:56 Integrated Voltage Measurement... 19:09:05 Voltage Offset Correction: v_off_ini = 3132.581 uV, v_off_fin = 3123.752 uV 19:09:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.720 uVs 19:09:09 I1Y Average and RMS of Measurements VT = -175.130 +- 1.134 uVs I1Y = -35.026 +- 0.227 uTm 19:09:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:09:17 Integrated Voltage Measurement... 19:09:26 Voltage Offset Correction: v_off_ini = 3126.477 uV, v_off_fin = 3128.191 uV 19:09:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.614 uVs 19:09:26 Integrated Voltage Measurement... 19:09:35 Voltage Offset Correction: v_off_ini = 3100.908 uV, v_off_fin = 3132.752 uV 19:09:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.941 uVs 19:09:35 Integrated Voltage Measurement... 19:09:44 Voltage Offset Correction: v_off_ini = 3125.213 uV, v_off_fin = 3119.047 uV 19:09:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -163.856 uVs 19:09:44 Integrated Voltage Measurement... 19:09:53 Voltage Offset Correction: v_off_ini = 3132.862 uV, v_off_fin = 3141.701 uV 19:09:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 141.526 uVs 19:09:53 Integrated Voltage Measurement... 19:10:02 Voltage Offset Correction: v_off_ini = 3153.739 uV, v_off_fin = 3134.485 uV 19:10:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.694 uVs 19:10:02 Integrated Voltage Measurement... 19:10:11 Voltage Offset Correction: v_off_ini = 3139.851 uV, v_off_fin = 3143.338 uV 19:10:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.070 uVs 19:10:14 I2X Average and RMS of Measurements VT = -151.283 +- 4.442 uVs I2X = 13.919 +- 0.409 uTm^2 19:10:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:10:21 Integrated Voltage Measurement... 19:10:30 Voltage Offset Correction: v_off_ini = 3125.819 uV, v_off_fin = 3131.541 uV 19:10:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.128 uVs 19:10:30 Integrated Voltage Measurement... 19:10:39 Voltage Offset Correction: v_off_ini = 3124.020 uV, v_off_fin = 3112.476 uV 19:10:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 168.228 uVs 19:10:39 Integrated Voltage Measurement... 19:10:48 Voltage Offset Correction: v_off_ini = 3110.409 uV, v_off_fin = 3101.329 uV 19:10:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -140.908 uVs 19:10:48 Integrated Voltage Measurement... 19:10:57 Voltage Offset Correction: v_off_ini = 3105.137 uV, v_off_fin = 3103.572 uV 19:10:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 166.428 uVs 19:10:57 Integrated Voltage Measurement... 19:11:06 Voltage Offset Correction: v_off_ini = 3111.214 uV, v_off_fin = 3119.904 uV 19:11:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.408 uVs 19:11:06 Integrated Voltage Measurement... 19:11:15 Voltage Offset Correction: v_off_ini = 3092.055 uV, v_off_fin = 3107.664 uV 19:11:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.063 uVs 19:11:18 I2Y Average and RMS of Measurements VT = -164.527 +- 7.681 uVs I2Y = -15.136 +- 0.707 uTm^2 19:11:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:11:27 Integrated Voltage Measurement... 19:11:36 Voltage Offset Correction: v_off_ini = 3116.416 uV, v_off_fin = 3106.665 uV 19:11:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -175.558 uVs 19:11:36 Integrated Voltage Measurement... 19:11:45 Voltage Offset Correction: v_off_ini = 3100.823 uV, v_off_fin = 3132.397 uV 19:11:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.418 uVs 19:11:45 Integrated Voltage Measurement... 19:11:54 Voltage Offset Correction: v_off_ini = 3151.116 uV, v_off_fin = 3143.379 uV 19:11:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.847 uVs 19:11:54 Integrated Voltage Measurement... 19:12:03 Voltage Offset Correction: v_off_ini = 3130.025 uV, v_off_fin = 3119.609 uV 19:12:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 192.050 uVs 19:12:03 Integrated Voltage Measurement... 19:12:12 Voltage Offset Correction: v_off_ini = 3099.468 uV, v_off_fin = 3083.094 uV 19:12:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -167.640 uVs 19:12:12 Integrated Voltage Measurement... 19:12:21 Voltage Offset Correction: v_off_ini = 3101.163 uV, v_off_fin = 3106.714 uV 19:12:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.094 uVs 19:12:25 I1X Average and RMS of Measurements VT = -179.101 +- 10.229 uVs I1X = 35.821 +- 2.047 uTm 19:12:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:12:32 Integrated Voltage Measurement... 19:12:40 Voltage Offset Correction: v_off_ini = 3137.962 uV, v_off_fin = 3115.267 uV 19:12:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.675 uVs 19:12:41 Integrated Voltage Measurement... 19:12:49 Voltage Offset Correction: v_off_ini = 3129.570 uV, v_off_fin = 3141.501 uV 19:12:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.448 uVs 19:12:50 Integrated Voltage Measurement... 19:12:58 Voltage Offset Correction: v_off_ini = 3151.617 uV, v_off_fin = 3138.304 uV 19:12:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.103 uVs 19:12:58 Integrated Voltage Measurement... 19:13:07 Voltage Offset Correction: v_off_ini = 3142.148 uV, v_off_fin = 3149.996 uV 19:13:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.581 uVs 19:13:07 Integrated Voltage Measurement... 19:13:16 Voltage Offset Correction: v_off_ini = 3144.435 uV, v_off_fin = 3127.793 uV 19:13:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.487 uVs 19:13:16 Integrated Voltage Measurement... 19:13:25 Voltage Offset Correction: v_off_ini = 3104.652 uV, v_off_fin = 3135.387 uV 19:13:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.934 uVs 19:13:30 I1Y Average and RMS of Measurements VT = -183.205 +- 2.129 uVs I1Y = -36.641 +- 0.426 uTm 19:13:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:13:37 Integrated Voltage Measurement... 19:13:46 Voltage Offset Correction: v_off_ini = 3128.582 uV, v_off_fin = 3094.673 uV 19:13:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -161.780 uVs 19:13:46 Integrated Voltage Measurement... 19:13:55 Voltage Offset Correction: v_off_ini = 3105.607 uV, v_off_fin = 3118.145 uV 19:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.142 uVs 19:13:55 Integrated Voltage Measurement... 19:14:04 Voltage Offset Correction: v_off_ini = 3123.310 uV, v_off_fin = 3110.504 uV 19:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.567 uVs 19:14:04 Integrated Voltage Measurement... 19:14:13 Voltage Offset Correction: v_off_ini = 3089.877 uV, v_off_fin = 3098.417 uV 19:14:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 129.695 uVs 19:14:13 Integrated Voltage Measurement... 19:14:22 Voltage Offset Correction: v_off_ini = 3109.471 uV, v_off_fin = 3091.582 uV 19:14:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -176.861 uVs 19:14:22 Integrated Voltage Measurement... 19:14:31 Voltage Offset Correction: v_off_ini = 3094.005 uV, v_off_fin = 3097.221 uV 19:14:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.769 uVs 19:14:34 I2X Average and RMS of Measurements VT = -149.469 +- 5.003 uVs I2X = 13.752 +- 0.460 uTm^2 19:14:39 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:14:41 Integrated Voltage Measurement... 19:14:50 Voltage Offset Correction: v_off_ini = 3123.349 uV, v_off_fin = 3106.068 uV 19:14:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.133 uVs 19:14:50 Integrated Voltage Measurement... 19:14:59 Voltage Offset Correction: v_off_ini = 3109.140 uV, v_off_fin = 3121.148 uV 19:14:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.229 uVs 19:15:00 Integrated Voltage Measurement... 19:15:08 Voltage Offset Correction: v_off_ini = 3136.318 uV, v_off_fin = 3122.758 uV 19:15:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.745 uVs 19:15:09 Integrated Voltage Measurement... 19:15:18 Voltage Offset Correction: v_off_ini = 3126.298 uV, v_off_fin = 3127.329 uV 19:15:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.274 uVs 19:15:18 Integrated Voltage Measurement... 19:15:27 Voltage Offset Correction: v_off_ini = 3146.997 uV, v_off_fin = 3129.547 uV 19:15:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.928 uVs 19:15:27 Integrated Voltage Measurement... 19:15:36 Voltage Offset Correction: v_off_ini = 3117.790 uV, v_off_fin = 3115.438 uV 19:15:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 166.776 uVs 19:15:38 I2Y Average and RMS of Measurements VT = -173.514 +- 4.435 uVs I2Y = -15.963 +- 0.408 uTm^2 19:15:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:15:47 Integrated Voltage Measurement... 19:15:56 Voltage Offset Correction: v_off_ini = 3118.869 uV, v_off_fin = 3109.357 uV 19:15:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -170.039 uVs 19:15:56 Integrated Voltage Measurement... 19:16:05 Voltage Offset Correction: v_off_ini = 3125.840 uV, v_off_fin = 3124.551 uV 19:16:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 179.307 uVs 19:16:05 Integrated Voltage Measurement... 19:16:14 Voltage Offset Correction: v_off_ini = 3113.963 uV, v_off_fin = 3113.723 uV 19:16:14 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = -164.890 uVs 19:16:14 Integrated Voltage Measurement... 19:16:23 Voltage Offset Correction: v_off_ini = 3126.619 uV, v_off_fin = 3126.634 uV 19:16:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 152.415 uVs 19:16:23 Integrated Voltage Measurement... 19:16:32 Voltage Offset Correction: v_off_ini = 3116.219 uV, v_off_fin = 3135.220 uV 19:16:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -167.357 uVs 19:16:32 Integrated Voltage Measurement... 19:16:41 Voltage Offset Correction: v_off_ini = 3116.398 uV, v_off_fin = 3125.203 uV 19:16:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 170.331 uVs 19:16:45 I1X Average and RMS of Measurements VT = -167.390 +- 6.621 uVs I1X = 33.480 +- 1.323 uTm 19:16:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:16:52 Integrated Voltage Measurement... 19:17:01 Voltage Offset Correction: v_off_ini = 3115.181 uV, v_off_fin = 3099.158 uV 19:17:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.464 uVs 19:17:01 Integrated Voltage Measurement... 19:17:10 Voltage Offset Correction: v_off_ini = 3126.116 uV, v_off_fin = 3125.099 uV 19:17:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.280 uVs 19:17:10 Integrated Voltage Measurement... 19:17:19 Voltage Offset Correction: v_off_ini = 3118.615 uV, v_off_fin = 3093.890 uV 19:17:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.232 uVs 19:17:19 Integrated Voltage Measurement... 19:17:28 Voltage Offset Correction: v_off_ini = 3094.899 uV, v_off_fin = 3107.231 uV 19:17:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.388 uVs 19:17:28 Integrated Voltage Measurement... 19:17:37 Voltage Offset Correction: v_off_ini = 3094.377 uV, v_off_fin = 3079.987 uV 19:17:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.705 uVs 19:17:37 Integrated Voltage Measurement... 19:17:46 Voltage Offset Correction: v_off_ini = 3083.271 uV, v_off_fin = 3082.163 uV 19:17:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.183 uVs 19:17:50 I1Y Average and RMS of Measurements VT = -196.709 +- 8.229 uVs I1Y = -39.342 +- 1.646 uTm 19:17:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:17:58 Integrated Voltage Measurement... 19:18:07 Voltage Offset Correction: v_off_ini = 3083.985 uV, v_off_fin = 3070.863 uV 19:18:07 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -116.937 uVs 19:18:07 Integrated Voltage Measurement... 19:18:16 Voltage Offset Correction: v_off_ini = 3078.739 uV, v_off_fin = 3073.690 uV 19:18:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.545 uVs 19:18:16 Integrated Voltage Measurement... 19:18:25 Voltage Offset Correction: v_off_ini = 3110.744 uV, v_off_fin = 3093.574 uV 19:18:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.719 uVs 19:18:25 Integrated Voltage Measurement... 19:18:34 Voltage Offset Correction: v_off_ini = 3097.251 uV, v_off_fin = 3128.642 uV 19:18:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.658 uVs 19:18:34 Integrated Voltage Measurement... 19:18:43 Voltage Offset Correction: v_off_ini = 3113.542 uV, v_off_fin = 3104.704 uV 19:18:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -163.529 uVs 19:18:43 Integrated Voltage Measurement... 19:18:52 Voltage Offset Correction: v_off_ini = 3109.107 uV, v_off_fin = 3106.780 uV 19:18:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.200 uVs 19:18:54 I2X Average and RMS of Measurements VT = -135.431 +- 9.855 uVs I2X = 12.460 +- 0.907 uTm^2 19:18:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:19:02 Integrated Voltage Measurement... 19:19:11 Voltage Offset Correction: v_off_ini = 3081.827 uV, v_off_fin = 3103.671 uV 19:19:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.935 uVs 19:19:11 Integrated Voltage Measurement... 19:19:20 Voltage Offset Correction: v_off_ini = 3115.700 uV, v_off_fin = 3107.848 uV 19:19:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.085 uVs 19:19:20 Integrated Voltage Measurement... 19:19:29 Voltage Offset Correction: v_off_ini = 3129.046 uV, v_off_fin = 3097.205 uV 19:19:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.954 uVs 19:19:29 Integrated Voltage Measurement... 19:19:38 Voltage Offset Correction: v_off_ini = 3101.951 uV, v_off_fin = 3115.673 uV 19:19:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.526 uVs 19:19:38 Integrated Voltage Measurement... 19:19:47 Voltage Offset Correction: v_off_ini = 3108.348 uV, v_off_fin = 3117.357 uV 19:19:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.900 uVs 19:19:47 Integrated Voltage Measurement... 19:19:56 Voltage Offset Correction: v_off_ini = 3107.272 uV, v_off_fin = 3115.142 uV 19:19:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.363 uVs 19:19:58 I2Y Average and RMS of Measurements VT = -193.627 +- 0.626 uVs I2Y = -17.814 +- 0.058 uTm^2 19:20:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:20:07 Integrated Voltage Measurement... 19:20:16 Voltage Offset Correction: v_off_ini = 3100.103 uV, v_off_fin = 3106.901 uV 19:20:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -195.464 uVs 19:20:16 Integrated Voltage Measurement... 19:20:25 Voltage Offset Correction: v_off_ini = 3097.906 uV, v_off_fin = 3104.676 uV 19:20:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 185.998 uVs 19:20:25 Integrated Voltage Measurement... 19:20:34 Voltage Offset Correction: v_off_ini = 3103.603 uV, v_off_fin = 3100.372 uV 19:20:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -176.847 uVs 19:20:34 Integrated Voltage Measurement... 19:20:43 Voltage Offset Correction: v_off_ini = 3086.745 uV, v_off_fin = 3096.154 uV 19:20:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 195.900 uVs 19:20:43 Integrated Voltage Measurement... 19:20:52 Voltage Offset Correction: v_off_ini = 3070.062 uV, v_off_fin = 3081.430 uV 19:20:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -175.440 uVs 19:20:52 Integrated Voltage Measurement... 19:21:01 Voltage Offset Correction: v_off_ini = 3068.620 uV, v_off_fin = 3085.719 uV 19:21:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.923 uVs 19:21:05 I1X Average and RMS of Measurements VT = -186.429 +- 3.491 uVs I1X = 37.286 +- 0.698 uTm 19:21:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:21:12 Integrated Voltage Measurement... 19:21:21 Voltage Offset Correction: v_off_ini = 3084.887 uV, v_off_fin = 3100.684 uV 19:21:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.100 uVs 19:21:21 Integrated Voltage Measurement... 19:21:30 Voltage Offset Correction: v_off_ini = 3090.433 uV, v_off_fin = 3096.332 uV 19:21:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.807 uVs 19:21:30 Integrated Voltage Measurement... 19:21:39 Voltage Offset Correction: v_off_ini = 3136.692 uV, v_off_fin = 3122.175 uV 19:21:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.415 uVs 19:21:39 Integrated Voltage Measurement... 19:21:48 Voltage Offset Correction: v_off_ini = 3110.447 uV, v_off_fin = 3127.206 uV 19:21:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.807 uVs 19:21:48 Integrated Voltage Measurement... 19:21:57 Voltage Offset Correction: v_off_ini = 3112.878 uV, v_off_fin = 3092.036 uV 19:21:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.551 uVs 19:21:57 Integrated Voltage Measurement... 19:22:06 Voltage Offset Correction: v_off_ini = 3103.035 uV, v_off_fin = 3120.248 uV 19:22:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.450 uVs 19:22:10 I1Y Average and RMS of Measurements VT = -207.855 +- 5.930 uVs I1Y = -41.571 +- 1.186 uTm 19:22:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:22:18 Integrated Voltage Measurement... 19:22:27 Voltage Offset Correction: v_off_ini = 3108.046 uV, v_off_fin = 3095.796 uV 19:22:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -161.790 uVs 19:22:27 Integrated Voltage Measurement... 19:22:36 Voltage Offset Correction: v_off_ini = 3127.883 uV, v_off_fin = 3129.862 uV 19:22:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.881 uVs 19:22:36 Integrated Voltage Measurement... 19:22:45 Voltage Offset Correction: v_off_ini = 3119.028 uV, v_off_fin = 3132.927 uV 19:22:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -170.381 uVs 19:22:45 Integrated Voltage Measurement... 19:22:54 Voltage Offset Correction: v_off_ini = 3120.984 uV, v_off_fin = 3116.393 uV 19:22:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 144.319 uVs 19:22:54 Integrated Voltage Measurement... 19:23:03 Voltage Offset Correction: v_off_ini = 3100.545 uV, v_off_fin = 3091.440 uV 19:23:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.998 uVs 19:23:03 Integrated Voltage Measurement... 19:23:12 Voltage Offset Correction: v_off_ini = 3095.520 uV, v_off_fin = 3110.053 uV 19:23:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.055 uVs 19:23:15 I2X Average and RMS of Measurements VT = -150.570 +- 7.557 uVs I2X = 13.853 +- 0.696 uTm^2 19:23:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:23:22 Integrated Voltage Measurement... 19:23:31 Voltage Offset Correction: v_off_ini = 3056.060 uV, v_off_fin = 3070.742 uV 19:23:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.666 uVs 19:23:31 Integrated Voltage Measurement... 19:23:40 Voltage Offset Correction: v_off_ini = 3073.621 uV, v_off_fin = 3087.405 uV 19:23:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.865 uVs 19:23:40 Integrated Voltage Measurement... 19:23:49 Voltage Offset Correction: v_off_ini = 3086.254 uV, v_off_fin = 3071.666 uV 19:23:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.568 uVs 19:23:49 Integrated Voltage Measurement... 19:23:58 Voltage Offset Correction: v_off_ini = 3072.776 uV, v_off_fin = 3091.610 uV 19:23:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.646 uVs 19:23:58 Integrated Voltage Measurement... 19:24:07 Voltage Offset Correction: v_off_ini = 3098.299 uV, v_off_fin = 3106.080 uV 19:24:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -205.083 uVs 19:24:07 Integrated Voltage Measurement... 19:24:16 Voltage Offset Correction: v_off_ini = 3084.533 uV, v_off_fin = 3074.962 uV 19:24:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.578 uVs 19:24:19 I2Y Average and RMS of Measurements VT = -198.901 +- 9.685 uVs I2Y = -18.299 +- 0.891 uTm^2 19:24:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:24:28 Integrated Voltage Measurement... 19:24:37 Voltage Offset Correction: v_off_ini = 3082.367 uV, v_off_fin = 3079.290 uV 19:24:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -179.902 uVs 19:24:37 Integrated Voltage Measurement... 19:24:46 Voltage Offset Correction: v_off_ini = 3077.681 uV, v_off_fin = 3068.195 uV 19:24:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.118 uVs 19:24:46 Integrated Voltage Measurement... 19:24:55 Voltage Offset Correction: v_off_ini = 3055.912 uV, v_off_fin = 3071.901 uV 19:24:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -172.656 uVs 19:24:55 Integrated Voltage Measurement... 19:25:04 Voltage Offset Correction: v_off_ini = 3063.538 uV, v_off_fin = 3051.402 uV 19:25:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 192.473 uVs 19:25:04 Integrated Voltage Measurement... 19:25:13 Voltage Offset Correction: v_off_ini = 3053.447 uV, v_off_fin = 3078.348 uV 19:25:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -175.290 uVs 19:25:13 Integrated Voltage Measurement... 19:25:22 Voltage Offset Correction: v_off_ini = 3070.284 uV, v_off_fin = 3061.118 uV 19:25:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 184.634 uVs 19:25:26 I1X Average and RMS of Measurements VT = -176.512 +- 6.803 uVs I1X = 35.304 +- 1.358 uTm 19:25:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:25:33 Integrated Voltage Measurement... 19:25:42 Voltage Offset Correction: v_off_ini = 3064.464 uV, v_off_fin = 3098.365 uV 19:25:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.084 uVs 19:25:42 Integrated Voltage Measurement... 19:25:51 Voltage Offset Correction: v_off_ini = 3103.572 uV, v_off_fin = 3100.976 uV 19:25:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.504 uVs 19:25:51 Integrated Voltage Measurement... 19:26:00 Voltage Offset Correction: v_off_ini = 3072.444 uV, v_off_fin = 3071.093 uV 19:26:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.802 uVs 19:26:00 Integrated Voltage Measurement... 19:26:09 Voltage Offset Correction: v_off_ini = 3074.305 uV, v_off_fin = 3090.420 uV 19:26:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.174 uVs 19:26:09 Integrated Voltage Measurement... 19:26:18 Voltage Offset Correction: v_off_ini = 3075.227 uV, v_off_fin = 3084.057 uV 19:26:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.855 uVs 19:26:18 Integrated Voltage Measurement... 19:26:27 Voltage Offset Correction: v_off_ini = 3078.669 uV, v_off_fin = 3085.056 uV 19:26:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.828 uVs 19:26:31 I1Y Average and RMS of Measurements VT = -213.208 +- 6.271 uVs I1Y = -42.642 +- 1.254 uTm 19:26:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:26:38 Integrated Voltage Measurement... 19:26:47 Voltage Offset Correction: v_off_ini = 3068.265 uV, v_off_fin = 3067.725 uV 19:26:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.657 uVs 19:26:47 Integrated Voltage Measurement... 19:26:56 Voltage Offset Correction: v_off_ini = 3076.099 uV, v_off_fin = 3085.810 uV 19:26:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.351 uVs 19:26:56 Integrated Voltage Measurement... 19:27:05 Voltage Offset Correction: v_off_ini = 3062.469 uV, v_off_fin = 3082.714 uV 19:27:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.342 uVs 19:27:05 Integrated Voltage Measurement... 19:27:14 Voltage Offset Correction: v_off_ini = 3094.177 uV, v_off_fin = 3091.493 uV 19:27:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.149 uVs 19:27:15 Integrated Voltage Measurement... 19:27:23 Voltage Offset Correction: v_off_ini = 3078.586 uV, v_off_fin = 3061.997 uV 19:27:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.639 uVs 19:27:24 Integrated Voltage Measurement... 19:27:33 Voltage Offset Correction: v_off_ini = 3058.112 uV, v_off_fin = 3056.105 uV 19:27:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.746 uVs 19:27:35 I2X Average and RMS of Measurements VT = -150.981 +- 2.696 uVs I2X = 13.890 +- 0.248 uTm^2 19:27:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:27:43 Integrated Voltage Measurement... 19:27:52 Voltage Offset Correction: v_off_ini = 3046.108 uV, v_off_fin = 3054.871 uV 19:27:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.633 uVs 19:27:52 Integrated Voltage Measurement... 19:28:01 Voltage Offset Correction: v_off_ini = 3072.462 uV, v_off_fin = 3055.691 uV 19:28:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.303 uVs 19:28:01 Integrated Voltage Measurement... 19:28:10 Voltage Offset Correction: v_off_ini = 3062.539 uV, v_off_fin = 3063.384 uV 19:28:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.840 uVs 19:28:10 Integrated Voltage Measurement... 19:28:19 Voltage Offset Correction: v_off_ini = 3054.356 uV, v_off_fin = 3075.038 uV 19:28:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.239 uVs 19:28:19 Integrated Voltage Measurement... 19:28:28 Voltage Offset Correction: v_off_ini = 3072.090 uV, v_off_fin = 3068.993 uV 19:28:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.389 uVs 19:28:28 Integrated Voltage Measurement... 19:28:37 Voltage Offset Correction: v_off_ini = 3075.198 uV, v_off_fin = 3076.114 uV 19:28:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.533 uVs 19:28:39 I2Y Average and RMS of Measurements VT = -220.656 +- 8.555 uVs I2Y = -20.300 +- 0.787 uTm^2 19:28:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:28:51 Integrated Voltage Measurement... 19:29:00 Voltage Offset Correction: v_off_ini = 3063.375 uV, v_off_fin = 3050.708 uV 19:29:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -166.557 uVs 19:29:00 Integrated Voltage Measurement... 19:29:09 Voltage Offset Correction: v_off_ini = 3050.415 uV, v_off_fin = 3047.943 uV 19:29:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.736 uVs 19:29:09 Integrated Voltage Measurement... 19:29:18 Voltage Offset Correction: v_off_ini = 3074.149 uV, v_off_fin = 3061.611 uV 19:29:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -200.745 uVs 19:29:18 Integrated Voltage Measurement... 19:29:27 Voltage Offset Correction: v_off_ini = 3089.089 uV, v_off_fin = 3078.277 uV 19:29:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.456 uVs 19:29:27 Integrated Voltage Measurement... 19:29:36 Voltage Offset Correction: v_off_ini = 3061.243 uV, v_off_fin = 3074.375 uV 19:29:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -168.004 uVs 19:29:36 Integrated Voltage Measurement... 19:29:45 Voltage Offset Correction: v_off_ini = 3058.089 uV, v_off_fin = 3069.784 uV 19:29:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 186.167 uVs 19:29:49 I1X Average and RMS of Measurements VT = -181.944 +- 7.184 uVs I1X = 36.391 +- 1.435 uTm 19:29:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:29:56 Integrated Voltage Measurement... 19:30:05 Voltage Offset Correction: v_off_ini = 3092.188 uV, v_off_fin = 3083.920 uV 19:30:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.079 uVs 19:30:05 Integrated Voltage Measurement... 19:30:14 Voltage Offset Correction: v_off_ini = 3113.131 uV, v_off_fin = 3112.584 uV 19:30:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.277 uVs 19:30:14 Integrated Voltage Measurement... 19:30:23 Voltage Offset Correction: v_off_ini = 3095.896 uV, v_off_fin = 3073.138 uV 19:30:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.688 uVs 19:30:23 Integrated Voltage Measurement... 19:30:32 Voltage Offset Correction: v_off_ini = 3063.549 uV, v_off_fin = 3084.922 uV 19:30:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.944 uVs 19:30:32 Integrated Voltage Measurement... 19:30:41 Voltage Offset Correction: v_off_ini = 3091.624 uV, v_off_fin = 3087.584 uV 19:30:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.813 uVs 19:30:41 Integrated Voltage Measurement... 19:30:50 Voltage Offset Correction: v_off_ini = 3089.150 uV, v_off_fin = 3076.855 uV 19:30:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.465 uVs 19:30:54 I1Y Average and RMS of Measurements VT = -199.711 +- 9.802 uVs I1Y = -39.942 +- 1.960 uTm 19:30:57 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:30:59 Integrated Voltage Measurement... 19:31:08 Voltage Offset Correction: v_off_ini = 3073.897 uV, v_off_fin = 3075.380 uV 19:31:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -163.338 uVs 19:31:08 Integrated Voltage Measurement... 19:31:17 Voltage Offset Correction: v_off_ini = 3090.588 uV, v_off_fin = 3086.124 uV 19:31:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 168.826 uVs 19:31:17 Integrated Voltage Measurement... 19:31:26 Voltage Offset Correction: v_off_ini = 3084.774 uV, v_off_fin = 3064.651 uV 19:31:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -168.983 uVs 19:31:26 Integrated Voltage Measurement... 19:31:35 Voltage Offset Correction: v_off_ini = 3089.762 uV, v_off_fin = 3088.778 uV 19:31:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.898 uVs 19:31:35 Integrated Voltage Measurement... 19:31:44 Voltage Offset Correction: v_off_ini = 3082.663 uV, v_off_fin = 3081.003 uV 19:31:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -175.548 uVs 19:31:45 Integrated Voltage Measurement... 19:31:53 Voltage Offset Correction: v_off_ini = 3075.553 uV, v_off_fin = 3072.910 uV 19:31:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 182.446 uVs 19:31:56 I2X Average and RMS of Measurements VT = -165.173 +- 11.676 uVs I2X = 15.197 +- 1.075 uTm^2 19:31:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:32:01 Integrated Voltage Measurement... 19:32:10 Voltage Offset Correction: v_off_ini = 3055.149 uV, v_off_fin = 3067.108 uV 19:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.365 uVs 19:32:10 Integrated Voltage Measurement... 19:32:19 Voltage Offset Correction: v_off_ini = 3083.820 uV, v_off_fin = 3087.762 uV 19:32:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.831 uVs 19:32:19 Integrated Voltage Measurement... 19:32:28 Voltage Offset Correction: v_off_ini = 3076.020 uV, v_off_fin = 3086.346 uV 19:32:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.066 uVs 19:32:28 Integrated Voltage Measurement... 19:32:37 Voltage Offset Correction: v_off_ini = 3075.568 uV, v_off_fin = 3062.794 uV 19:32:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 156.811 uVs 19:32:37 Integrated Voltage Measurement... 19:32:46 Voltage Offset Correction: v_off_ini = 3077.581 uV, v_off_fin = 3078.235 uV 19:32:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.240 uVs 19:32:46 Integrated Voltage Measurement... 19:32:55 Voltage Offset Correction: v_off_ini = 3094.081 uV, v_off_fin = 3070.434 uV 19:32:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.725 uVs 19:32:58 I2Y Average and RMS of Measurements VT = -194.173 +- 10.035 uVs I2Y = -17.864 +- 0.923 uTm^2 19:33:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:33:06 Integrated Voltage Measurement... 19:33:15 Voltage Offset Correction: v_off_ini = 3092.067 uV, v_off_fin = 3083.639 uV 19:33:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -189.825 uVs 19:33:15 Integrated Voltage Measurement... 19:33:24 Voltage Offset Correction: v_off_ini = 3069.470 uV, v_off_fin = 3077.083 uV 19:33:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 182.088 uVs 19:33:24 Integrated Voltage Measurement... 19:33:33 Voltage Offset Correction: v_off_ini = 3061.515 uV, v_off_fin = 3047.305 uV 19:33:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.258 uVs 19:33:33 Integrated Voltage Measurement... 19:33:42 Voltage Offset Correction: v_off_ini = 3079.412 uV, v_off_fin = 3064.301 uV 19:33:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 181.102 uVs 19:33:42 Integrated Voltage Measurement... 19:33:51 Voltage Offset Correction: v_off_ini = 3077.858 uV, v_off_fin = 3043.025 uV 19:33:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -196.620 uVs 19:33:51 Integrated Voltage Measurement... 19:34:00 Voltage Offset Correction: v_off_ini = 3078.328 uV, v_off_fin = 3078.939 uV 19:34:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 201.480 uVs 19:34:04 I1X Average and RMS of Measurements VT = -185.395 +- 11.385 uVs I1X = 37.080 +- 2.277 uTm 19:34:06 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:34:11 Integrated Voltage Measurement... 19:34:20 Voltage Offset Correction: v_off_ini = 3063.277 uV, v_off_fin = 3049.953 uV 19:34:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.132 uVs 19:34:20 Integrated Voltage Measurement... 19:34:29 Voltage Offset Correction: v_off_ini = 3067.209 uV, v_off_fin = 3058.104 uV 19:34:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.966 uVs 19:34:29 Integrated Voltage Measurement... 19:34:38 Voltage Offset Correction: v_off_ini = 3040.561 uV, v_off_fin = 3028.780 uV 19:34:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.459 uVs 19:34:38 Integrated Voltage Measurement... 19:34:47 Voltage Offset Correction: v_off_ini = 3046.608 uV, v_off_fin = 3071.106 uV 19:34:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.596 uVs 19:34:47 Integrated Voltage Measurement... 19:34:56 Voltage Offset Correction: v_off_ini = 3079.798 uV, v_off_fin = 3048.127 uV 19:34:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.031 uVs 19:34:56 Integrated Voltage Measurement... 19:35:05 Voltage Offset Correction: v_off_ini = 3070.733 uV, v_off_fin = 3049.294 uV 19:35:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.017 uVs 19:35:09 I1Y Average and RMS of Measurements VT = -197.534 +- 8.848 uVs I1Y = -39.507 +- 1.770 uTm 19:35:11 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:35:14 Integrated Voltage Measurement... 19:35:23 Voltage Offset Correction: v_off_ini = 3040.539 uV, v_off_fin = 3036.675 uV 19:35:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.069 uVs 19:35:23 Integrated Voltage Measurement... 19:35:32 Voltage Offset Correction: v_off_ini = 3047.922 uV, v_off_fin = 3070.572 uV 19:35:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 149.692 uVs 19:35:32 Integrated Voltage Measurement... 19:35:41 Voltage Offset Correction: v_off_ini = 3045.571 uV, v_off_fin = 3043.665 uV 19:35:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -177.270 uVs 19:35:41 Integrated Voltage Measurement... 19:35:50 Voltage Offset Correction: v_off_ini = 3060.770 uV, v_off_fin = 3064.893 uV 19:35:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.437 uVs 19:35:50 Integrated Voltage Measurement... 19:35:59 Voltage Offset Correction: v_off_ini = 3038.098 uV, v_off_fin = 3054.351 uV 19:35:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.677 uVs 19:35:59 Integrated Voltage Measurement... 19:36:08 Voltage Offset Correction: v_off_ini = 3072.643 uV, v_off_fin = 3069.643 uV 19:36:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.900 uVs 19:36:11 I2X Average and RMS of Measurements VT = -148.508 +- 6.541 uVs I2X = 13.663 +- 0.601 uTm^2 19:36:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:36:16 Integrated Voltage Measurement... 19:36:25 Voltage Offset Correction: v_off_ini = 3078.268 uV, v_off_fin = 3080.028 uV 19:36:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.255 uVs 19:36:25 Integrated Voltage Measurement... 19:36:34 Voltage Offset Correction: v_off_ini = 3080.625 uV, v_off_fin = 3044.833 uV 19:36:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.568 uVs 19:36:34 Integrated Voltage Measurement... 19:36:43 Voltage Offset Correction: v_off_ini = 3057.116 uV, v_off_fin = 3065.264 uV 19:36:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.424 uVs 19:36:43 Integrated Voltage Measurement... 19:36:52 Voltage Offset Correction: v_off_ini = 3035.950 uV, v_off_fin = 3052.289 uV 19:36:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.188 uVs 19:36:52 Integrated Voltage Measurement... 19:37:01 Voltage Offset Correction: v_off_ini = 3069.186 uV, v_off_fin = 3070.680 uV 19:37:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.417 uVs 19:37:01 Integrated Voltage Measurement... 19:37:10 Voltage Offset Correction: v_off_ini = 3072.363 uV, v_off_fin = 3086.792 uV 19:37:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.831 uVs 19:37:12 I2Y Average and RMS of Measurements VT = -190.281 +- 10.208 uVs I2Y = -17.506 +- 0.939 uTm^2 19:37:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:37:20 Integrated Voltage Measurement... 19:37:29 Voltage Offset Correction: v_off_ini = 3064.527 uV, v_off_fin = 3067.040 uV 19:37:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -181.936 uVs 19:37:30 Integrated Voltage Measurement... 19:37:38 Voltage Offset Correction: v_off_ini = 3067.571 uV, v_off_fin = 3066.080 uV 19:37:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.182 uVs 19:37:39 Integrated Voltage Measurement... 19:37:47 Voltage Offset Correction: v_off_ini = 3074.719 uV, v_off_fin = 3083.277 uV 19:37:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.452 uVs 19:37:48 Integrated Voltage Measurement... 19:37:56 Voltage Offset Correction: v_off_ini = 3066.031 uV, v_off_fin = 3075.796 uV 19:37:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 198.994 uVs 19:37:57 Integrated Voltage Measurement... 19:38:05 Voltage Offset Correction: v_off_ini = 3042.552 uV, v_off_fin = 3066.579 uV 19:38:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.807 uVs 19:38:06 Integrated Voltage Measurement... 19:38:14 Voltage Offset Correction: v_off_ini = 3109.038 uV, v_off_fin = 3065.720 uV 19:38:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.044 uVs 19:38:19 I1X Average and RMS of Measurements VT = -170.236 +- 5.813 uVs I1X = 34.049 +- 1.161 uTm 19:38:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:38:25 Integrated Voltage Measurement... 19:38:34 Voltage Offset Correction: v_off_ini = 3056.281 uV, v_off_fin = 3043.869 uV 19:38:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -190.799 uVs 19:38:34 Integrated Voltage Measurement... 19:38:43 Voltage Offset Correction: v_off_ini = 3038.195 uV, v_off_fin = 3032.828 uV 19:38:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.780 uVs 19:38:43 Integrated Voltage Measurement... 19:38:52 Voltage Offset Correction: v_off_ini = 3022.225 uV, v_off_fin = 3002.719 uV 19:38:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.939 uVs 19:38:52 Integrated Voltage Measurement... 19:39:01 Voltage Offset Correction: v_off_ini = 3009.711 uV, v_off_fin = 2985.438 uV 19:39:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.877 uVs 19:39:01 Integrated Voltage Measurement... 19:39:10 Voltage Offset Correction: v_off_ini = 2982.031 uV, v_off_fin = 2994.672 uV 19:39:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.900 uVs 19:39:10 Integrated Voltage Measurement... 19:39:19 Voltage Offset Correction: v_off_ini = 2998.550 uV, v_off_fin = 3001.251 uV 19:39:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.186 uVs 19:39:24 I1Y Average and RMS of Measurements VT = -200.414 +- 3.568 uVs I1Y = -40.085 +- 0.714 uTm 19:39:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:39:29 Integrated Voltage Measurement... 19:39:38 Voltage Offset Correction: v_off_ini = 2998.233 uV, v_off_fin = 2989.955 uV 19:39:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.113 uVs 19:39:38 Integrated Voltage Measurement... 19:39:47 Voltage Offset Correction: v_off_ini = 2989.560 uV, v_off_fin = 3005.333 uV 19:39:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 168.985 uVs 19:39:47 Integrated Voltage Measurement... 19:39:56 Voltage Offset Correction: v_off_ini = 3012.930 uV, v_off_fin = 3014.057 uV 19:39:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.527 uVs 19:39:56 Integrated Voltage Measurement... 19:40:05 Voltage Offset Correction: v_off_ini = 2988.269 uV, v_off_fin = 3006.805 uV 19:40:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.756 uVs 19:40:05 Integrated Voltage Measurement... 19:40:14 Voltage Offset Correction: v_off_ini = 3022.785 uV, v_off_fin = 3009.950 uV 19:40:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.875 uVs 19:40:14 Integrated Voltage Measurement... 19:40:23 Voltage Offset Correction: v_off_ini = 3021.963 uV, v_off_fin = 3020.835 uV 19:40:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 169.802 uVs 19:40:25 I2X Average and RMS of Measurements VT = -148.176 +- 11.478 uVs I2X = 13.632 +- 1.056 uTm^2 19:40:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:40:30 Integrated Voltage Measurement... 19:40:39 Voltage Offset Correction: v_off_ini = 3025.836 uV, v_off_fin = 3019.804 uV 19:40:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.169 uVs 19:40:39 Integrated Voltage Measurement... 19:40:48 Voltage Offset Correction: v_off_ini = 3025.751 uV, v_off_fin = 3022.545 uV 19:40:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.232 uVs 19:40:48 Integrated Voltage Measurement... 19:40:57 Voltage Offset Correction: v_off_ini = 3031.132 uV, v_off_fin = 3032.486 uV 19:40:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -175.948 uVs 19:40:57 Integrated Voltage Measurement... 19:41:06 Voltage Offset Correction: v_off_ini = 3018.179 uV, v_off_fin = 3022.499 uV 19:41:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.776 uVs 19:41:06 Integrated Voltage Measurement... 19:41:15 Voltage Offset Correction: v_off_ini = 3034.303 uV, v_off_fin = 3016.623 uV 19:41:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.032 uVs 19:41:16 Integrated Voltage Measurement... 19:41:24 Voltage Offset Correction: v_off_ini = 2993.221 uV, v_off_fin = 3006.817 uV 19:41:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.664 uVs 19:41:27 I2Y Average and RMS of Measurements VT = -180.303 +- 2.154 uVs I2Y = -16.588 +- 0.198 uTm^2 19:41:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:41:35 Integrated Voltage Measurement... 19:41:44 Voltage Offset Correction: v_off_ini = 3021.980 uV, v_off_fin = 3012.987 uV 19:41:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -157.081 uVs 19:41:44 Integrated Voltage Measurement... 19:41:53 Voltage Offset Correction: v_off_ini = 2987.062 uV, v_off_fin = 3021.138 uV 19:41:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 193.385 uVs 19:41:53 Integrated Voltage Measurement... 19:42:02 Voltage Offset Correction: v_off_ini = 3019.279 uV, v_off_fin = 3021.255 uV 19:42:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.103 uVs 19:42:02 Integrated Voltage Measurement... 19:42:11 Voltage Offset Correction: v_off_ini = 3018.856 uV, v_off_fin = 3005.365 uV 19:42:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 184.902 uVs 19:42:11 Integrated Voltage Measurement... 19:42:20 Voltage Offset Correction: v_off_ini = 2987.179 uV, v_off_fin = 2996.619 uV 19:42:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -196.988 uVs 19:42:20 Integrated Voltage Measurement... 19:42:29 Voltage Offset Correction: v_off_ini = 3006.410 uV, v_off_fin = 2992.473 uV 19:42:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 192.797 uVs 19:42:33 I1X Average and RMS of Measurements VT = -179.376 +- 11.362 uVs I1X = 35.876 +- 2.272 uTm 19:42:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:42:40 Integrated Voltage Measurement... 19:42:49 Voltage Offset Correction: v_off_ini = 3001.494 uV, v_off_fin = 2990.334 uV 19:42:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.261 uVs 19:42:49 Integrated Voltage Measurement... 19:42:58 Voltage Offset Correction: v_off_ini = 2998.247 uV, v_off_fin = 3009.924 uV 19:42:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.519 uVs 19:42:58 Integrated Voltage Measurement... 19:43:07 Voltage Offset Correction: v_off_ini = 3009.607 uV, v_off_fin = 3014.917 uV 19:43:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.619 uVs 19:43:07 Integrated Voltage Measurement... 19:43:16 Voltage Offset Correction: v_off_ini = 3004.494 uV, v_off_fin = 2994.330 uV 19:43:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.882 uVs 19:43:16 Integrated Voltage Measurement... 19:43:25 Voltage Offset Correction: v_off_ini = 2988.998 uV, v_off_fin = 2996.494 uV 19:43:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.706 uVs 19:43:25 Integrated Voltage Measurement... 19:43:34 Voltage Offset Correction: v_off_ini = 2990.279 uV, v_off_fin = 3002.904 uV 19:43:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.913 uVs 19:43:38 I1Y Average and RMS of Measurements VT = -199.650 +- 7.586 uVs I1Y = -39.929 +- 1.519 uTm 19:43:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:43:43 Integrated Voltage Measurement... 19:43:52 Voltage Offset Correction: v_off_ini = 2990.706 uV, v_off_fin = 2981.887 uV 19:43:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -130.324 uVs 19:43:52 Integrated Voltage Measurement... 19:44:01 Voltage Offset Correction: v_off_ini = 2999.137 uV, v_off_fin = 3012.484 uV 19:44:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.670 uVs 19:44:02 Integrated Voltage Measurement... 19:44:10 Voltage Offset Correction: v_off_ini = 2976.610 uV, v_off_fin = 2966.843 uV 19:44:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -163.128 uVs 19:44:11 Integrated Voltage Measurement... 19:44:19 Voltage Offset Correction: v_off_ini = 2992.450 uV, v_off_fin = 3005.781 uV 19:44:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 139.167 uVs 19:44:20 Integrated Voltage Measurement... 19:44:29 Voltage Offset Correction: v_off_ini = 2991.449 uV, v_off_fin = 2978.016 uV 19:44:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.149 uVs 19:44:29 Integrated Voltage Measurement... 19:44:38 Voltage Offset Correction: v_off_ini = 2973.677 uV, v_off_fin = 2990.523 uV 19:44:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.311 uVs 19:44:40 I2X Average and RMS of Measurements VT = -142.625 +- 6.803 uVs I2X = 13.122 +- 0.626 uTm^2 19:44:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:44:45 Integrated Voltage Measurement... 19:44:54 Voltage Offset Correction: v_off_ini = 2958.920 uV, v_off_fin = 2982.727 uV 19:44:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.412 uVs 19:44:54 Integrated Voltage Measurement... 19:45:03 Voltage Offset Correction: v_off_ini = 2965.472 uV, v_off_fin = 2958.173 uV 19:45:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.580 uVs 19:45:03 Integrated Voltage Measurement... 19:45:12 Voltage Offset Correction: v_off_ini = 2958.777 uV, v_off_fin = 2932.859 uV 19:45:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.674 uVs 19:45:12 Integrated Voltage Measurement... 19:45:21 Voltage Offset Correction: v_off_ini = 2941.969 uV, v_off_fin = 2949.071 uV 19:45:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.683 uVs 19:45:21 Integrated Voltage Measurement... 19:45:30 Voltage Offset Correction: v_off_ini = 2939.933 uV, v_off_fin = 2959.564 uV 19:45:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.051 uVs 19:45:30 Integrated Voltage Measurement... 19:45:39 Voltage Offset Correction: v_off_ini = 2948.804 uV, v_off_fin = 2955.223 uV 19:45:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.384 uVs 19:45:42 I2Y Average and RMS of Measurements VT = -190.964 +- 4.894 uVs I2Y = -17.569 +- 0.450 uTm^2 19:45:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:45:50 Integrated Voltage Measurement... 19:45:59 Voltage Offset Correction: v_off_ini = 2907.877 uV, v_off_fin = 2912.790 uV 19:45:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -155.332 uVs 19:45:59 Integrated Voltage Measurement... 19:46:08 Voltage Offset Correction: v_off_ini = 2891.754 uV, v_off_fin = 2919.970 uV 19:46:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 189.516 uVs 19:46:08 Integrated Voltage Measurement... 19:46:17 Voltage Offset Correction: v_off_ini = 2929.519 uV, v_off_fin = 2931.063 uV 19:46:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -163.290 uVs 19:46:17 Integrated Voltage Measurement... 19:46:26 Voltage Offset Correction: v_off_ini = 2922.159 uV, v_off_fin = 2941.502 uV 19:46:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.994 uVs 19:46:26 Integrated Voltage Measurement... 19:46:35 Voltage Offset Correction: v_off_ini = 2915.969 uV, v_off_fin = 2932.050 uV 19:46:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -174.671 uVs 19:46:35 Integrated Voltage Measurement... 19:46:44 Voltage Offset Correction: v_off_ini = 2930.491 uV, v_off_fin = 2933.932 uV 19:46:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 189.597 uVs 19:46:48 I1X Average and RMS of Measurements VT = -168.400 +- 13.168 uVs I1X = 33.682 +- 2.633 uTm 19:46:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:46:55 Integrated Voltage Measurement... 19:47:04 Voltage Offset Correction: v_off_ini = 2939.898 uV, v_off_fin = 2959.089 uV 19:47:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.993 uVs 19:47:04 Integrated Voltage Measurement... 19:47:13 Voltage Offset Correction: v_off_ini = 2935.785 uV, v_off_fin = 2940.984 uV 19:47:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.694 uVs 19:47:13 Integrated Voltage Measurement... 19:47:22 Voltage Offset Correction: v_off_ini = 2934.073 uV, v_off_fin = 2934.357 uV 19:47:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -203.879 uVs 19:47:22 Integrated Voltage Measurement... 19:47:31 Voltage Offset Correction: v_off_ini = 2951.154 uV, v_off_fin = 2972.938 uV 19:47:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.505 uVs 19:47:31 Integrated Voltage Measurement... 19:47:40 Voltage Offset Correction: v_off_ini = 2953.502 uV, v_off_fin = 2927.776 uV 19:47:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.369 uVs 19:47:40 Integrated Voltage Measurement... 19:47:49 Voltage Offset Correction: v_off_ini = 2937.699 uV, v_off_fin = 2965.181 uV 19:47:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 219.841 uVs 19:47:53 I1Y Average and RMS of Measurements VT = -196.547 +- 8.521 uVs I1Y = -39.305 +- 1.702 uTm 19:47:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:47:58 Integrated Voltage Measurement... 19:48:07 Voltage Offset Correction: v_off_ini = 2966.345 uV, v_off_fin = 2967.381 uV 19:48:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.579 uVs 19:48:07 Integrated Voltage Measurement... 19:48:16 Voltage Offset Correction: v_off_ini = 2978.538 uV, v_off_fin = 2969.362 uV 19:48:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.464 uVs 19:48:16 Integrated Voltage Measurement... 19:48:25 Voltage Offset Correction: v_off_ini = 2958.881 uV, v_off_fin = 2965.306 uV 19:48:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.825 uVs 19:48:25 Integrated Voltage Measurement... 19:48:34 Voltage Offset Correction: v_off_ini = 2988.068 uV, v_off_fin = 2986.691 uV 19:48:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 136.306 uVs 19:48:34 Integrated Voltage Measurement... 19:48:43 Voltage Offset Correction: v_off_ini = 2968.599 uV, v_off_fin = 2987.291 uV 19:48:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -128.275 uVs 19:48:43 Integrated Voltage Measurement... 19:48:52 Voltage Offset Correction: v_off_ini = 2981.635 uV, v_off_fin = 2988.469 uV 19:48:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 145.882 uVs 19:48:55 I2X Average and RMS of Measurements VT = -128.888 +- 12.287 uVs I2X = 11.858 +- 1.131 uTm^2 19:48:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:49:00 Integrated Voltage Measurement... 19:49:09 Voltage Offset Correction: v_off_ini = 2951.649 uV, v_off_fin = 2959.264 uV 19:49:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.275 uVs 19:49:09 Integrated Voltage Measurement... 19:49:18 Voltage Offset Correction: v_off_ini = 2971.650 uV, v_off_fin = 2967.549 uV 19:49:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.076 uVs 19:49:18 Integrated Voltage Measurement... 19:49:27 Voltage Offset Correction: v_off_ini = 2970.460 uV, v_off_fin = 2977.560 uV 19:49:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.202 uVs 19:49:27 Integrated Voltage Measurement... 19:49:36 Voltage Offset Correction: v_off_ini = 2988.491 uV, v_off_fin = 2960.194 uV 19:49:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.170 uVs 19:49:36 Integrated Voltage Measurement... 19:49:45 Voltage Offset Correction: v_off_ini = 2961.577 uV, v_off_fin = 2968.149 uV 19:49:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.714 uVs 19:49:45 Integrated Voltage Measurement... 19:49:54 Voltage Offset Correction: v_off_ini = 2988.199 uV, v_off_fin = 2976.259 uV 19:49:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.909 uVs 19:49:56 I2Y Average and RMS of Measurements VT = -188.558 +- 8.178 uVs I2Y = -17.347 +- 0.752 uTm^2 19:50:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:50:18 Integrated Voltage Measurement... 19:50:27 Voltage Offset Correction: v_off_ini = 2976.376 uV, v_off_fin = 2967.979 uV 19:50:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -206.963 uVs 19:50:27 Integrated Voltage Measurement... 19:50:36 Voltage Offset Correction: v_off_ini = 2982.098 uV, v_off_fin = 2983.346 uV 19:50:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 190.559 uVs 19:50:36 Integrated Voltage Measurement... 19:50:45 Voltage Offset Correction: v_off_ini = 2953.150 uV, v_off_fin = 2958.316 uV 19:50:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -194.565 uVs 19:50:45 Integrated Voltage Measurement... 19:50:54 Voltage Offset Correction: v_off_ini = 2943.887 uV, v_off_fin = 2958.596 uV 19:50:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 200.170 uVs 19:50:54 Integrated Voltage Measurement... 19:51:03 Voltage Offset Correction: v_off_ini = 2949.151 uV, v_off_fin = 2988.813 uV 19:51:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -184.620 uVs 19:51:03 Integrated Voltage Measurement... 19:51:12 Voltage Offset Correction: v_off_ini = 2984.032 uV, v_off_fin = 2950.298 uV 19:51:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 195.336 uVs 19:51:16 I1X Average and RMS of Measurements VT = -195.369 +- 3.854 uVs I1X = 39.075 +- 0.771 uTm 19:51:18 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:51:23 Integrated Voltage Measurement... 19:51:32 Voltage Offset Correction: v_off_ini = 2982.692 uV, v_off_fin = 2961.100 uV 19:51:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.495 uVs 19:51:32 Integrated Voltage Measurement... 19:51:41 Voltage Offset Correction: v_off_ini = 2964.711 uV, v_off_fin = 2957.561 uV 19:51:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.993 uVs 19:51:41 Integrated Voltage Measurement... 19:51:50 Voltage Offset Correction: v_off_ini = 2976.332 uV, v_off_fin = 2967.294 uV 19:51:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.641 uVs 19:51:50 Integrated Voltage Measurement... 19:51:59 Voltage Offset Correction: v_off_ini = 2987.396 uV, v_off_fin = 2970.967 uV 19:51:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.890 uVs 19:51:59 Integrated Voltage Measurement... 19:52:08 Voltage Offset Correction: v_off_ini = 2982.730 uV, v_off_fin = 2972.643 uV 19:52:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.668 uVs 19:52:08 Integrated Voltage Measurement... 19:52:16 Voltage Offset Correction: v_off_ini = 2949.593 uV, v_off_fin = 2948.084 uV 19:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.865 uVs 19:52:21 I1Y Average and RMS of Measurements VT = -169.592 +- 4.787 uVs I1Y = -33.918 +- 0.957 uTm 19:52:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:52:28 Integrated Voltage Measurement... 19:52:37 Voltage Offset Correction: v_off_ini = 2924.417 uV, v_off_fin = 2930.528 uV 19:52:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -167.213 uVs 19:52:37 Integrated Voltage Measurement... 19:52:46 Voltage Offset Correction: v_off_ini = 2929.502 uV, v_off_fin = 2963.737 uV 19:52:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.414 uVs 19:52:46 Integrated Voltage Measurement... 19:52:55 Voltage Offset Correction: v_off_ini = 2940.331 uV, v_off_fin = 2964.653 uV 19:52:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -179.535 uVs 19:52:56 Integrated Voltage Measurement... 19:53:04 Voltage Offset Correction: v_off_ini = 2971.796 uV, v_off_fin = 3000.269 uV 19:53:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 171.064 uVs 19:53:05 Integrated Voltage Measurement... 19:53:14 Voltage Offset Correction: v_off_ini = 2955.141 uV, v_off_fin = 2937.598 uV 19:53:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.150 uVs 19:53:14 Integrated Voltage Measurement... 19:53:23 Voltage Offset Correction: v_off_ini = 2959.842 uV, v_off_fin = 2969.300 uV 19:53:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.259 uVs 19:53:25 I2X Average and RMS of Measurements VT = -158.939 +- 11.594 uVs I2X = 14.622 +- 1.067 uTm^2 19:53:30 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:53:33 Integrated Voltage Measurement... 19:53:42 Voltage Offset Correction: v_off_ini = 2949.342 uV, v_off_fin = 2941.877 uV 19:53:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -152.893 uVs 19:53:42 Integrated Voltage Measurement... 19:53:51 Voltage Offset Correction: v_off_ini = 2964.448 uV, v_off_fin = 2968.100 uV 19:53:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.506 uVs 19:53:51 Integrated Voltage Measurement... 19:54:00 Voltage Offset Correction: v_off_ini = 2956.722 uV, v_off_fin = 2953.915 uV 19:54:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -161.882 uVs 19:54:00 Integrated Voltage Measurement... 19:54:09 Voltage Offset Correction: v_off_ini = 2958.184 uV, v_off_fin = 2941.596 uV 19:54:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 146.243 uVs 19:54:09 Integrated Voltage Measurement... 19:54:18 Voltage Offset Correction: v_off_ini = 2945.797 uV, v_off_fin = 2959.795 uV 19:54:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -157.501 uVs 19:54:18 Integrated Voltage Measurement... 19:54:27 Voltage Offset Correction: v_off_ini = 2967.477 uV, v_off_fin = 2957.236 uV 19:54:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 153.505 uVs 19:54:29 I2Y Average and RMS of Measurements VT = -155.922 +- 1.715 uVs I2Y = -14.345 +- 0.158 uTm^2 19:54:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:54:38 Integrated Voltage Measurement... 19:54:47 Voltage Offset Correction: v_off_ini = 2943.212 uV, v_off_fin = 2944.440 uV 19:54:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -221.585 uVs 19:54:47 Integrated Voltage Measurement... 19:54:56 Voltage Offset Correction: v_off_ini = 2949.457 uV, v_off_fin = 2955.111 uV 19:54:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 172.610 uVs 19:54:56 Integrated Voltage Measurement... 19:55:05 Voltage Offset Correction: v_off_ini = 2967.915 uV, v_off_fin = 2960.857 uV 19:55:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -162.383 uVs 19:55:05 Integrated Voltage Measurement... 19:55:14 Voltage Offset Correction: v_off_ini = 2955.697 uV, v_off_fin = 2950.953 uV 19:55:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.365 uVs 19:55:14 Integrated Voltage Measurement... 19:55:23 Voltage Offset Correction: v_off_ini = 2962.100 uV, v_off_fin = 2962.808 uV 19:55:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -175.668 uVs 19:55:23 Integrated Voltage Measurement... 19:55:32 Voltage Offset Correction: v_off_ini = 2953.172 uV, v_off_fin = 2960.310 uV 19:55:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 192.558 uVs 19:55:36 I1X Average and RMS of Measurements VT = -181.528 +- 13.888 uVs I1X = 36.307 +- 2.779 uTm 19:55:39 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:55:43 Integrated Voltage Measurement... 19:55:52 Voltage Offset Correction: v_off_ini = 2915.340 uV, v_off_fin = 2917.808 uV 19:55:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.453 uVs 19:55:52 Integrated Voltage Measurement... 19:56:01 Voltage Offset Correction: v_off_ini = 2952.812 uV, v_off_fin = 2932.776 uV 19:56:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.881 uVs 19:56:01 Integrated Voltage Measurement... 19:56:10 Voltage Offset Correction: v_off_ini = 2909.299 uV, v_off_fin = 2908.145 uV 19:56:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.084 uVs 19:56:10 Integrated Voltage Measurement... 19:56:19 Voltage Offset Correction: v_off_ini = 2906.245 uV, v_off_fin = 2910.272 uV 19:56:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.629 uVs 19:56:19 Integrated Voltage Measurement... 19:56:28 Voltage Offset Correction: v_off_ini = 2925.921 uV, v_off_fin = 2918.812 uV 19:56:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.848 uVs 19:56:28 Integrated Voltage Measurement... 19:56:37 Voltage Offset Correction: v_off_ini = 2937.810 uV, v_off_fin = 2945.964 uV 19:56:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.757 uVs 19:56:41 I1Y Average and RMS of Measurements VT = -168.442 +- 3.221 uVs I1Y = -33.688 +- 0.644 uTm 19:56:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:56:49 Integrated Voltage Measurement... 19:56:58 Voltage Offset Correction: v_off_ini = 2936.179 uV, v_off_fin = 2921.448 uV 19:56:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -132.488 uVs 19:56:58 Integrated Voltage Measurement... 19:57:07 Voltage Offset Correction: v_off_ini = 2958.259 uV, v_off_fin = 2952.938 uV 19:57:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.625 uVs 19:57:07 Integrated Voltage Measurement... 19:57:16 Voltage Offset Correction: v_off_ini = 2939.724 uV, v_off_fin = 2940.407 uV 19:57:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.969 uVs 19:57:16 Integrated Voltage Measurement... 19:57:25 Voltage Offset Correction: v_off_ini = 2932.626 uV, v_off_fin = 2953.437 uV 19:57:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 160.508 uVs 19:57:25 Integrated Voltage Measurement... 19:57:34 Voltage Offset Correction: v_off_ini = 2932.817 uV, v_off_fin = 2941.802 uV 19:57:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -166.820 uVs 19:57:34 Integrated Voltage Measurement... 19:57:43 Voltage Offset Correction: v_off_ini = 2944.380 uV, v_off_fin = 2958.976 uV 19:57:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.874 uVs 19:57:45 I2X Average and RMS of Measurements VT = -141.881 +- 15.572 uVs I2X = 13.053 +- 1.433 uTm^2 19:57:50 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:57:53 Integrated Voltage Measurement... 19:58:02 Voltage Offset Correction: v_off_ini = 2942.974 uV, v_off_fin = 2924.983 uV 19:58:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.500 uVs 19:58:02 Integrated Voltage Measurement... 19:58:11 Voltage Offset Correction: v_off_ini = 2891.695 uV, v_off_fin = 2900.573 uV 19:58:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 164.917 uVs 19:58:11 Integrated Voltage Measurement... 19:58:20 Voltage Offset Correction: v_off_ini = 2955.024 uV, v_off_fin = 2935.652 uV 19:58:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.527 uVs 19:58:20 Integrated Voltage Measurement... 19:58:29 Voltage Offset Correction: v_off_ini = 2929.010 uV, v_off_fin = 2931.692 uV 19:58:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.967 uVs 19:58:29 Integrated Voltage Measurement... 19:58:38 Voltage Offset Correction: v_off_ini = 2947.076 uV, v_off_fin = 2946.677 uV 19:58:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -143.015 uVs 19:58:38 Integrated Voltage Measurement... 19:58:47 Voltage Offset Correction: v_off_ini = 2941.197 uV, v_off_fin = 2942.638 uV 19:58:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 151.093 uVs 19:58:50 I2Y Average and RMS of Measurements VT = -158.503 +- 8.096 uVs I2Y = -14.582 +- 0.745 uTm^2 19:58:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:58:59 Integrated Voltage Measurement... 19:59:07 Voltage Offset Correction: v_off_ini = 2923.421 uV, v_off_fin = 2905.277 uV 19:59:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -205.559 uVs 19:59:08 Integrated Voltage Measurement... 19:59:16 Voltage Offset Correction: v_off_ini = 2892.335 uV, v_off_fin = 2918.181 uV 19:59:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.668 uVs 19:59:17 Integrated Voltage Measurement... 19:59:26 Voltage Offset Correction: v_off_ini = 2900.006 uV, v_off_fin = 2890.738 uV 19:59:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -183.794 uVs 19:59:26 Integrated Voltage Measurement... 19:59:35 Voltage Offset Correction: v_off_ini = 2895.814 uV, v_off_fin = 2891.385 uV 19:59:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 200.056 uVs 19:59:35 Integrated Voltage Measurement... 19:59:44 Voltage Offset Correction: v_off_ini = 2891.722 uV, v_off_fin = 2883.551 uV 19:59:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -166.084 uVs 19:59:44 Integrated Voltage Measurement... 19:59:53 Voltage Offset Correction: v_off_ini = 2912.095 uV, v_off_fin = 2910.190 uV 19:59:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.791 uVs 19:59:57 I1X Average and RMS of Measurements VT = -184.825 +- 13.872 uVs I1X = 36.968 +- 2.777 uTm 19:59:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:00:03 Integrated Voltage Measurement... 20:00:12 Voltage Offset Correction: v_off_ini = 2903.900 uV, v_off_fin = 2904.061 uV 20:00:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.524 uVs 20:00:12 Integrated Voltage Measurement... 20:00:21 Voltage Offset Correction: v_off_ini = 2904.981 uV, v_off_fin = 2906.588 uV 20:00:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.843 uVs 20:00:21 Integrated Voltage Measurement... 20:00:30 Voltage Offset Correction: v_off_ini = 2891.432 uV, v_off_fin = 2880.092 uV 20:00:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.133 uVs 20:00:30 Integrated Voltage Measurement... 20:00:39 Voltage Offset Correction: v_off_ini = 2882.158 uV, v_off_fin = 2907.075 uV 20:00:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.379 uVs 20:00:39 Integrated Voltage Measurement... 20:00:48 Voltage Offset Correction: v_off_ini = 2913.837 uV, v_off_fin = 2893.368 uV 20:00:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.723 uVs 20:00:48 Integrated Voltage Measurement... 20:00:57 Voltage Offset Correction: v_off_ini = 2908.733 uV, v_off_fin = 2910.683 uV 20:00:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.589 uVs 20:01:02 I1Y Average and RMS of Measurements VT = -188.198 +- 4.793 uVs I1Y = -37.640 +- 0.959 uTm 20:01:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:01:09 Integrated Voltage Measurement... 20:01:18 Voltage Offset Correction: v_off_ini = 2868.506 uV, v_off_fin = 2862.954 uV 20:01:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -168.097 uVs 20:01:18 Integrated Voltage Measurement... 20:01:27 Voltage Offset Correction: v_off_ini = 2875.794 uV, v_off_fin = 2886.851 uV 20:01:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 163.287 uVs 20:01:27 Integrated Voltage Measurement... 20:01:36 Voltage Offset Correction: v_off_ini = 2892.990 uV, v_off_fin = 2860.232 uV 20:01:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.922 uVs 20:01:36 Integrated Voltage Measurement... 20:01:45 Voltage Offset Correction: v_off_ini = 2868.250 uV, v_off_fin = 2902.828 uV 20:01:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.049 uVs 20:01:45 Integrated Voltage Measurement... 20:01:54 Voltage Offset Correction: v_off_ini = 2890.063 uV, v_off_fin = 2877.204 uV 20:01:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.859 uVs 20:01:54 Integrated Voltage Measurement... 20:02:03 Voltage Offset Correction: v_off_ini = 2891.021 uV, v_off_fin = 2879.506 uV 20:02:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 153.467 uVs 20:02:06 I2X Average and RMS of Measurements VT = -156.447 +- 6.707 uVs I2X = 14.394 +- 0.617 uTm^2 20:02:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:02:13 Integrated Voltage Measurement... 20:02:22 Voltage Offset Correction: v_off_ini = 2891.745 uV, v_off_fin = 2890.270 uV 20:02:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -156.611 uVs 20:02:23 Integrated Voltage Measurement... 20:02:31 Voltage Offset Correction: v_off_ini = 2873.020 uV, v_off_fin = 2905.709 uV 20:02:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.991 uVs 20:02:32 Integrated Voltage Measurement... 20:02:41 Voltage Offset Correction: v_off_ini = 2879.741 uV, v_off_fin = 2859.995 uV 20:02:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.639 uVs 20:02:41 Integrated Voltage Measurement... 20:02:50 Voltage Offset Correction: v_off_ini = 2880.198 uV, v_off_fin = 2881.714 uV 20:02:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 174.759 uVs 20:02:50 Integrated Voltage Measurement... 20:02:59 Voltage Offset Correction: v_off_ini = 2885.049 uV, v_off_fin = 2874.684 uV 20:02:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.838 uVs 20:02:59 Integrated Voltage Measurement... 20:03:08 Voltage Offset Correction: v_off_ini = 2868.011 uV, v_off_fin = 2872.147 uV 20:03:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.642 uVs 20:03:10 I2Y Average and RMS of Measurements VT = -179.747 +- 9.348 uVs I2Y = -16.537 +- 0.860 uTm^2 20:03:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:03:19 Integrated Voltage Measurement... 20:03:28 Voltage Offset Correction: v_off_ini = 2864.518 uV, v_off_fin = 2868.722 uV 20:03:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -198.572 uVs 20:03:28 Integrated Voltage Measurement... 20:03:37 Voltage Offset Correction: v_off_ini = 2871.508 uV, v_off_fin = 2883.109 uV 20:03:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 178.990 uVs 20:03:37 Integrated Voltage Measurement... 20:03:46 Voltage Offset Correction: v_off_ini = 2882.787 uV, v_off_fin = 2897.462 uV 20:03:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.439 uVs 20:03:46 Integrated Voltage Measurement... 20:03:55 Voltage Offset Correction: v_off_ini = 2901.612 uV, v_off_fin = 2911.407 uV 20:03:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.767 uVs 20:03:55 Integrated Voltage Measurement... 20:04:04 Voltage Offset Correction: v_off_ini = 2872.517 uV, v_off_fin = 2901.457 uV 20:04:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.949 uVs 20:04:04 Integrated Voltage Measurement... 20:04:13 Voltage Offset Correction: v_off_ini = 2892.076 uV, v_off_fin = 2897.621 uV 20:04:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 201.067 uVs 20:04:17 I1X Average and RMS of Measurements VT = -187.297 +- 7.385 uVs I1X = 37.462 +- 1.477 uTm 20:04:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:04:24 Integrated Voltage Measurement... 20:04:33 Voltage Offset Correction: v_off_ini = 2883.943 uV, v_off_fin = 2892.561 uV 20:04:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.781 uVs 20:04:33 Integrated Voltage Measurement... 20:04:42 Voltage Offset Correction: v_off_ini = 2898.260 uV, v_off_fin = 2894.677 uV 20:04:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.266 uVs 20:04:42 Integrated Voltage Measurement... 20:04:51 Voltage Offset Correction: v_off_ini = 2896.779 uV, v_off_fin = 2892.354 uV 20:04:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.358 uVs 20:04:51 Integrated Voltage Measurement... 20:05:00 Voltage Offset Correction: v_off_ini = 2903.597 uV, v_off_fin = 2906.845 uV 20:05:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.740 uVs 20:05:00 Integrated Voltage Measurement... 20:05:09 Voltage Offset Correction: v_off_ini = 2875.497 uV, v_off_fin = 2876.316 uV 20:05:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.338 uVs 20:05:09 Integrated Voltage Measurement... 20:05:18 Voltage Offset Correction: v_off_ini = 2880.902 uV, v_off_fin = 2902.835 uV 20:05:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.277 uVs 20:05:22 I1Y Average and RMS of Measurements VT = -188.627 +- 1.598 uVs I1Y = -37.727 +- 0.319 uTm 20:05:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:05:30 Integrated Voltage Measurement... 20:05:39 Voltage Offset Correction: v_off_ini = 2868.316 uV, v_off_fin = 2868.547 uV 20:05:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -143.765 uVs 20:05:39 Integrated Voltage Measurement... 20:05:48 Voltage Offset Correction: v_off_ini = 2873.154 uV, v_off_fin = 2888.527 uV 20:05:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.193 uVs 20:05:48 Integrated Voltage Measurement... 20:05:57 Voltage Offset Correction: v_off_ini = 2893.757 uV, v_off_fin = 2849.921 uV 20:05:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -137.434 uVs 20:05:57 Integrated Voltage Measurement... 20:06:06 Voltage Offset Correction: v_off_ini = 2880.195 uV, v_off_fin = 2885.214 uV 20:06:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.957 uVs 20:06:06 Integrated Voltage Measurement... 20:06:15 Voltage Offset Correction: v_off_ini = 2847.035 uV, v_off_fin = 2838.286 uV 20:06:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -159.177 uVs 20:06:15 Integrated Voltage Measurement... 20:06:24 Voltage Offset Correction: v_off_ini = 2837.015 uV, v_off_fin = 2866.640 uV 20:06:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.525 uVs 20:06:26 I2X Average and RMS of Measurements VT = -148.342 +- 7.002 uVs I2X = 13.648 +- 0.644 uTm^2 20:06:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:06:34 Integrated Voltage Measurement... 20:06:43 Voltage Offset Correction: v_off_ini = 2857.496 uV, v_off_fin = 2834.892 uV 20:06:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -175.029 uVs 20:06:43 Integrated Voltage Measurement... 20:06:52 Voltage Offset Correction: v_off_ini = 2842.275 uV, v_off_fin = 2823.573 uV 20:06:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.155 uVs 20:06:52 Integrated Voltage Measurement... 20:07:01 Voltage Offset Correction: v_off_ini = 2831.454 uV, v_off_fin = 2837.576 uV 20:07:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.753 uVs 20:07:01 Integrated Voltage Measurement... 20:07:10 Voltage Offset Correction: v_off_ini = 2816.229 uV, v_off_fin = 2847.590 uV 20:07:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.588 uVs 20:07:10 Integrated Voltage Measurement... 20:07:19 Voltage Offset Correction: v_off_ini = 2820.292 uV, v_off_fin = 2837.558 uV 20:07:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.231 uVs 20:07:19 Integrated Voltage Measurement... 20:07:28 Voltage Offset Correction: v_off_ini = 2819.807 uV, v_off_fin = 2817.822 uV 20:07:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.126 uVs 20:07:30 I2Y Average and RMS of Measurements VT = -180.813 +- 5.463 uVs I2Y = -16.635 +- 0.503 uTm^2 20:07:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:07:39 Integrated Voltage Measurement... 20:07:48 Voltage Offset Correction: v_off_ini = 2847.430 uV, v_off_fin = 2843.574 uV 20:07:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -194.999 uVs 20:07:48 Integrated Voltage Measurement... 20:07:57 Voltage Offset Correction: v_off_ini = 2851.132 uV, v_off_fin = 2877.541 uV 20:07:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 177.663 uVs 20:07:57 Integrated Voltage Measurement... 20:08:06 Voltage Offset Correction: v_off_ini = 2856.297 uV, v_off_fin = 2857.343 uV 20:08:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -181.774 uVs 20:08:06 Integrated Voltage Measurement... 20:08:15 Voltage Offset Correction: v_off_ini = 2841.829 uV, v_off_fin = 2852.733 uV 20:08:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 182.130 uVs 20:08:15 Integrated Voltage Measurement... 20:08:24 Voltage Offset Correction: v_off_ini = 2852.614 uV, v_off_fin = 2839.917 uV 20:08:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.019 uVs 20:08:24 Integrated Voltage Measurement... 20:08:33 Voltage Offset Correction: v_off_ini = 2836.615 uV, v_off_fin = 2842.859 uV 20:08:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 209.353 uVs 20:08:38 I1X Average and RMS of Measurements VT = -187.323 +- 4.842 uVs I1X = 37.465 +- 0.968 uTm 20:08:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:08:44 Integrated Voltage Measurement... 20:08:53 Voltage Offset Correction: v_off_ini = 2882.401 uV, v_off_fin = 2864.699 uV 20:08:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.834 uVs 20:08:53 Integrated Voltage Measurement... 20:09:02 Voltage Offset Correction: v_off_ini = 2854.187 uV, v_off_fin = 2850.191 uV 20:09:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.114 uVs 20:09:02 Integrated Voltage Measurement... 20:09:11 Voltage Offset Correction: v_off_ini = 2840.438 uV, v_off_fin = 2836.767 uV 20:09:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.482 uVs 20:09:11 Integrated Voltage Measurement... 20:09:20 Voltage Offset Correction: v_off_ini = 2821.474 uV, v_off_fin = 2862.626 uV 20:09:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.319 uVs 20:09:20 Integrated Voltage Measurement... 20:09:29 Voltage Offset Correction: v_off_ini = 2833.108 uV, v_off_fin = 2845.489 uV 20:09:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.268 uVs 20:09:29 Integrated Voltage Measurement... 20:09:38 Voltage Offset Correction: v_off_ini = 2878.340 uV, v_off_fin = 2876.535 uV 20:09:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.110 uVs 20:09:42 I1Y Average and RMS of Measurements VT = -204.021 +- 2.787 uVs I1Y = -40.804 +- 0.557 uTm 20:09:47 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:09:50 Integrated Voltage Measurement... 20:09:59 Voltage Offset Correction: v_off_ini = 2837.418 uV, v_off_fin = 2852.520 uV 20:09:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.146 uVs 20:09:59 Integrated Voltage Measurement... 20:10:08 Voltage Offset Correction: v_off_ini = 2882.657 uV, v_off_fin = 2871.654 uV 20:10:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.786 uVs 20:10:08 Integrated Voltage Measurement... 20:10:17 Voltage Offset Correction: v_off_ini = 2846.632 uV, v_off_fin = 2854.472 uV 20:10:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -176.380 uVs 20:10:17 Integrated Voltage Measurement... 20:10:26 Voltage Offset Correction: v_off_ini = 2860.400 uV, v_off_fin = 2874.125 uV 20:10:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.978 uVs 20:10:26 Integrated Voltage Measurement... 20:10:35 Voltage Offset Correction: v_off_ini = 2854.229 uV, v_off_fin = 2875.254 uV 20:10:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.044 uVs 20:10:35 Integrated Voltage Measurement... 20:10:44 Voltage Offset Correction: v_off_ini = 2869.017 uV, v_off_fin = 2875.851 uV 20:10:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.590 uVs 20:10:47 I2X Average and RMS of Measurements VT = -138.154 +- 24.827 uVs I2X = 12.711 +- 2.284 uTm^2 20:10:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:10:54 Integrated Voltage Measurement... 20:11:03 Voltage Offset Correction: v_off_ini = 2877.744 uV, v_off_fin = 2879.026 uV 20:11:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.036 uVs 20:11:03 Integrated Voltage Measurement... 20:11:12 Voltage Offset Correction: v_off_ini = 2870.327 uV, v_off_fin = 2885.676 uV 20:11:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.870 uVs 20:11:12 Integrated Voltage Measurement... 20:11:21 Voltage Offset Correction: v_off_ini = 2903.488 uV, v_off_fin = 2897.104 uV 20:11:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -160.898 uVs 20:11:21 Integrated Voltage Measurement... 20:11:30 Voltage Offset Correction: v_off_ini = 2890.632 uV, v_off_fin = 2890.323 uV 20:11:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.605 uVs 20:11:30 Integrated Voltage Measurement... 20:11:39 Voltage Offset Correction: v_off_ini = 2894.762 uV, v_off_fin = 2906.702 uV 20:11:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.394 uVs 20:11:39 Integrated Voltage Measurement... 20:11:48 Voltage Offset Correction: v_off_ini = 2892.409 uV, v_off_fin = 2914.662 uV 20:11:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.893 uVs 20:11:51 I2Y Average and RMS of Measurements VT = -191.616 +- 13.962 uVs I2Y = -17.629 +- 1.285 uTm^2 20:11:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:12:03 Integrated Voltage Measurement... 20:12:12 Voltage Offset Correction: v_off_ini = 2907.611 uV, v_off_fin = 2899.276 uV 20:12:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -195.583 uVs 20:12:12 Integrated Voltage Measurement... 20:12:21 Voltage Offset Correction: v_off_ini = 2894.137 uV, v_off_fin = 2897.527 uV 20:12:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 165.975 uVs 20:12:21 Integrated Voltage Measurement... 20:12:30 Voltage Offset Correction: v_off_ini = 2898.768 uV, v_off_fin = 2879.433 uV 20:12:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -207.599 uVs 20:12:30 Integrated Voltage Measurement... 20:12:39 Voltage Offset Correction: v_off_ini = 2894.748 uV, v_off_fin = 2910.639 uV 20:12:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 190.194 uVs 20:12:39 Integrated Voltage Measurement... 20:12:48 Voltage Offset Correction: v_off_ini = 2893.008 uV, v_off_fin = 2877.578 uV 20:12:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -176.996 uVs 20:12:48 Integrated Voltage Measurement... 20:12:57 Voltage Offset Correction: v_off_ini = 2894.580 uV, v_off_fin = 2902.531 uV 20:12:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 218.695 uVs 20:13:01 I1X Average and RMS of Measurements VT = -192.507 +- 8.304 uVs I1X = 38.503 +- 1.661 uTm 20:13:03 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:13:08 Integrated Voltage Measurement... 20:13:17 Voltage Offset Correction: v_off_ini = 2875.137 uV, v_off_fin = 2880.235 uV 20:13:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.910 uVs 20:13:17 Integrated Voltage Measurement... 20:13:26 Voltage Offset Correction: v_off_ini = 2896.541 uV, v_off_fin = 2914.001 uV 20:13:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.957 uVs 20:13:26 Integrated Voltage Measurement... 20:13:35 Voltage Offset Correction: v_off_ini = 2926.791 uV, v_off_fin = 2911.605 uV 20:13:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.865 uVs 20:13:35 Integrated Voltage Measurement... 20:13:44 Voltage Offset Correction: v_off_ini = 2931.767 uV, v_off_fin = 2922.687 uV 20:13:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.800 uVs 20:13:44 Integrated Voltage Measurement... 20:13:53 Voltage Offset Correction: v_off_ini = 2888.524 uV, v_off_fin = 2905.678 uV 20:13:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.289 uVs 20:13:53 Integrated Voltage Measurement... 20:14:02 Voltage Offset Correction: v_off_ini = 2903.630 uV, v_off_fin = 2903.355 uV 20:14:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.161 uVs 20:14:06 I1Y Average and RMS of Measurements VT = -190.664 +- 6.150 uVs I1Y = -38.133 +- 1.230 uTm 20:14:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:14:11 Integrated Voltage Measurement... 20:14:20 Voltage Offset Correction: v_off_ini = 2910.493 uV, v_off_fin = 2903.814 uV 20:14:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -172.291 uVs 20:14:20 Integrated Voltage Measurement... 20:14:29 Voltage Offset Correction: v_off_ini = 2899.162 uV, v_off_fin = 2905.351 uV 20:14:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 181.929 uVs 20:14:29 Integrated Voltage Measurement... 20:14:38 Voltage Offset Correction: v_off_ini = 2893.832 uV, v_off_fin = 2886.816 uV 20:14:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -175.094 uVs 20:14:38 Integrated Voltage Measurement... 20:14:47 Voltage Offset Correction: v_off_ini = 2881.915 uV, v_off_fin = 2899.087 uV 20:14:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.642 uVs 20:14:47 Integrated Voltage Measurement... 20:14:56 Voltage Offset Correction: v_off_ini = 2914.875 uV, v_off_fin = 2892.026 uV 20:14:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -172.406 uVs 20:14:56 Integrated Voltage Measurement... 20:15:05 Voltage Offset Correction: v_off_ini = 2943.549 uV, v_off_fin = 2947.113 uV 20:15:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 134.283 uVs 20:15:07 I2X Average and RMS of Measurements VT = -159.608 +- 12.542 uVs I2X = 14.684 +- 1.154 uTm^2 20:15:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:15:13 Integrated Voltage Measurement... 20:15:21 Voltage Offset Correction: v_off_ini = 2900.925 uV, v_off_fin = 2888.654 uV 20:15:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.203 uVs 20:15:22 Integrated Voltage Measurement... 20:15:31 Voltage Offset Correction: v_off_ini = 2914.321 uV, v_off_fin = 2926.253 uV 20:15:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 168.766 uVs 20:15:31 Integrated Voltage Measurement... 20:15:40 Voltage Offset Correction: v_off_ini = 2908.938 uV, v_off_fin = 2901.356 uV 20:15:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.075 uVs 20:15:40 Integrated Voltage Measurement... 20:15:49 Voltage Offset Correction: v_off_ini = 2879.173 uV, v_off_fin = 2900.835 uV 20:15:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 195.537 uVs 20:15:49 Integrated Voltage Measurement... 20:15:58 Voltage Offset Correction: v_off_ini = 2912.576 uV, v_off_fin = 2896.502 uV 20:15:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.710 uVs 20:15:58 Integrated Voltage Measurement... 20:16:07 Voltage Offset Correction: v_off_ini = 2926.737 uV, v_off_fin = 2914.571 uV 20:16:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.757 uVs 20:16:09 I2Y Average and RMS of Measurements VT = -181.508 +- 6.841 uVs I2Y = -16.699 +- 0.629 uTm^2 20:16:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:16:17 Integrated Voltage Measurement... 20:16:26 Voltage Offset Correction: v_off_ini = 2873.374 uV, v_off_fin = 2907.873 uV 20:16:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -161.395 uVs 20:16:26 Integrated Voltage Measurement... 20:16:35 Voltage Offset Correction: v_off_ini = 2906.949 uV, v_off_fin = 2924.620 uV 20:16:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.800 uVs 20:16:35 Integrated Voltage Measurement... 20:16:44 Voltage Offset Correction: v_off_ini = 2894.313 uV, v_off_fin = 2887.962 uV 20:16:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -160.314 uVs 20:16:44 Integrated Voltage Measurement... 20:16:53 Voltage Offset Correction: v_off_ini = 2885.432 uV, v_off_fin = 2910.025 uV 20:16:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.422 uVs 20:16:53 Integrated Voltage Measurement... 20:17:02 Voltage Offset Correction: v_off_ini = 2906.468 uV, v_off_fin = 2893.139 uV 20:17:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -192.517 uVs 20:17:02 Integrated Voltage Measurement... 20:17:11 Voltage Offset Correction: v_off_ini = 2886.437 uV, v_off_fin = 2908.141 uV 20:17:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 200.107 uVs 20:17:16 I1X Average and RMS of Measurements VT = -174.259 +- 15.668 uVs I1X = 34.855 +- 3.132 uTm 20:17:18 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:17:22 Integrated Voltage Measurement... 20:17:31 Voltage Offset Correction: v_off_ini = 2873.567 uV, v_off_fin = 2859.821 uV 20:17:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.828 uVs 20:17:31 Integrated Voltage Measurement... 20:17:40 Voltage Offset Correction: v_off_ini = 2890.942 uV, v_off_fin = 2890.099 uV 20:17:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.143 uVs 20:17:40 Integrated Voltage Measurement... 20:17:49 Voltage Offset Correction: v_off_ini = 2900.618 uV, v_off_fin = 2876.025 uV 20:17:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.813 uVs 20:17:49 Integrated Voltage Measurement... 20:17:58 Voltage Offset Correction: v_off_ini = 2889.218 uV, v_off_fin = 2891.369 uV 20:17:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.522 uVs 20:17:58 Integrated Voltage Measurement... 20:18:07 Voltage Offset Correction: v_off_ini = 2870.114 uV, v_off_fin = 2859.454 uV 20:18:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.255 uVs 20:18:07 Integrated Voltage Measurement... 20:18:16 Voltage Offset Correction: v_off_ini = 2894.079 uV, v_off_fin = 2896.425 uV 20:18:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.049 uVs 20:18:20 I1Y Average and RMS of Measurements VT = -178.935 +- 7.478 uVs I1Y = -35.787 +- 1.496 uTm 20:18:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:18:26 Integrated Voltage Measurement... 20:18:35 Voltage Offset Correction: v_off_ini = 2888.395 uV, v_off_fin = 2867.576 uV 20:18:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.032 uVs 20:18:35 Integrated Voltage Measurement... 20:18:44 Voltage Offset Correction: v_off_ini = 2869.580 uV, v_off_fin = 2863.534 uV 20:18:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 166.182 uVs 20:18:44 Integrated Voltage Measurement... 20:18:53 Voltage Offset Correction: v_off_ini = 2845.508 uV, v_off_fin = 2835.812 uV 20:18:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -160.239 uVs 20:18:53 Integrated Voltage Measurement... 20:19:02 Voltage Offset Correction: v_off_ini = 2854.175 uV, v_off_fin = 2863.791 uV 20:19:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.845 uVs 20:19:02 Integrated Voltage Measurement... 20:19:11 Voltage Offset Correction: v_off_ini = 2857.580 uV, v_off_fin = 2848.940 uV 20:19:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -160.437 uVs 20:19:11 Integrated Voltage Measurement... 20:19:20 Voltage Offset Correction: v_off_ini = 2860.563 uV, v_off_fin = 2850.917 uV 20:19:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 164.802 uVs 20:19:22 I2X Average and RMS of Measurements VT = -150.589 +- 10.741 uVs I2X = 13.854 +- 0.988 uTm^2 20:19:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:19:27 Integrated Voltage Measurement... 20:19:36 Voltage Offset Correction: v_off_ini = 2845.284 uV, v_off_fin = 2826.966 uV 20:19:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -192.631 uVs 20:19:36 Integrated Voltage Measurement... 20:19:45 Voltage Offset Correction: v_off_ini = 2826.000 uV, v_off_fin = 2812.121 uV 20:19:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.771 uVs 20:19:45 Integrated Voltage Measurement... 20:19:54 Voltage Offset Correction: v_off_ini = 2812.389 uV, v_off_fin = 2834.890 uV 20:19:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.780 uVs 20:19:54 Integrated Voltage Measurement... 20:20:03 Voltage Offset Correction: v_off_ini = 2858.143 uV, v_off_fin = 2818.204 uV 20:20:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.245 uVs 20:20:03 Integrated Voltage Measurement... 20:20:12 Voltage Offset Correction: v_off_ini = 2836.453 uV, v_off_fin = 2834.808 uV 20:20:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -150.005 uVs 20:20:12 Integrated Voltage Measurement... 20:20:21 Voltage Offset Correction: v_off_ini = 2816.186 uV, v_off_fin = 2840.729 uV 20:20:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.014 uVs 20:20:24 I2Y Average and RMS of Measurements VT = -180.574 +- 9.741 uVs I2Y = -16.613 +- 0.896 uTm^2 20:20:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:20:32 Integrated Voltage Measurement... 20:20:41 Voltage Offset Correction: v_off_ini = 2853.753 uV, v_off_fin = 2862.181 uV 20:20:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -200.525 uVs 20:20:41 Integrated Voltage Measurement... 20:20:50 Voltage Offset Correction: v_off_ini = 2846.304 uV, v_off_fin = 2867.025 uV 20:20:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 189.880 uVs 20:20:50 Integrated Voltage Measurement... 20:20:59 Voltage Offset Correction: v_off_ini = 2844.269 uV, v_off_fin = 2813.279 uV 20:20:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -164.215 uVs 20:20:59 Integrated Voltage Measurement... 20:21:08 Voltage Offset Correction: v_off_ini = 2822.384 uV, v_off_fin = 2842.188 uV 20:21:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 172.703 uVs 20:21:08 Integrated Voltage Measurement... 20:21:17 Voltage Offset Correction: v_off_ini = 2848.776 uV, v_off_fin = 2811.554 uV 20:21:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -226.096 uVs 20:21:17 Integrated Voltage Measurement... 20:21:26 Voltage Offset Correction: v_off_ini = 2819.833 uV, v_off_fin = 2839.413 uV 20:21:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 173.675 uVs 20:21:30 I1X Average and RMS of Measurements VT = -187.849 +- 13.843 uVs I1X = 37.570 +- 2.769 uTm 20:21:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:21:37 Integrated Voltage Measurement... 20:21:46 Voltage Offset Correction: v_off_ini = 2826.634 uV, v_off_fin = 2814.960 uV 20:21:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.031 uVs 20:21:46 Integrated Voltage Measurement... 20:21:55 Voltage Offset Correction: v_off_ini = 2799.108 uV, v_off_fin = 2837.279 uV 20:21:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.322 uVs 20:21:55 Integrated Voltage Measurement... 20:22:04 Voltage Offset Correction: v_off_ini = 2828.803 uV, v_off_fin = 2838.332 uV 20:22:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.062 uVs 20:22:04 Integrated Voltage Measurement... 20:22:13 Voltage Offset Correction: v_off_ini = 2820.909 uV, v_off_fin = 2835.846 uV 20:22:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.536 uVs 20:22:13 Integrated Voltage Measurement... 20:22:22 Voltage Offset Correction: v_off_ini = 2818.120 uV, v_off_fin = 2810.004 uV 20:22:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.899 uVs 20:22:22 Integrated Voltage Measurement... 20:22:31 Voltage Offset Correction: v_off_ini = 2829.703 uV, v_off_fin = 2827.819 uV 20:22:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.887 uVs 20:22:35 I1Y Average and RMS of Measurements VT = -186.123 +- 10.192 uVs I1Y = -37.225 +- 2.038 uTm 20:22:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:22:40 Integrated Voltage Measurement... 20:22:49 Voltage Offset Correction: v_off_ini = 2807.163 uV, v_off_fin = 2788.754 uV 20:22:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -159.705 uVs 20:22:49 Integrated Voltage Measurement... 20:22:58 Voltage Offset Correction: v_off_ini = 2785.252 uV, v_off_fin = 2796.250 uV 20:22:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.071 uVs 20:22:58 Integrated Voltage Measurement... 20:23:07 Voltage Offset Correction: v_off_ini = 2788.444 uV, v_off_fin = 2776.091 uV 20:23:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.301 uVs 20:23:07 Integrated Voltage Measurement... 20:23:16 Voltage Offset Correction: v_off_ini = 2797.723 uV, v_off_fin = 2800.325 uV 20:23:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 159.713 uVs 20:23:17 Integrated Voltage Measurement... 20:23:25 Voltage Offset Correction: v_off_ini = 2780.007 uV, v_off_fin = 2775.596 uV 20:23:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.114 uVs 20:23:26 Integrated Voltage Measurement... 20:23:34 Voltage Offset Correction: v_off_ini = 2785.982 uV, v_off_fin = 2796.272 uV 20:23:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.040 uVs 20:23:37 I2X Average and RMS of Measurements VT = -142.991 +- 13.856 uVs I2X = 13.155 +- 1.275 uTm^2 20:23:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:23:42 Integrated Voltage Measurement... 20:23:51 Voltage Offset Correction: v_off_ini = 2784.923 uV, v_off_fin = 2791.500 uV 20:23:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.852 uVs 20:23:51 Integrated Voltage Measurement... 20:24:00 Voltage Offset Correction: v_off_ini = 2801.085 uV, v_off_fin = 2799.316 uV 20:24:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.010 uVs 20:24:00 Integrated Voltage Measurement... 20:24:09 Voltage Offset Correction: v_off_ini = 2807.130 uV, v_off_fin = 2774.002 uV 20:24:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.738 uVs 20:24:09 Integrated Voltage Measurement... 20:24:18 Voltage Offset Correction: v_off_ini = 2798.383 uV, v_off_fin = 2797.100 uV 20:24:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 150.118 uVs 20:24:18 Integrated Voltage Measurement... 20:24:27 Voltage Offset Correction: v_off_ini = 2775.950 uV, v_off_fin = 2799.638 uV 20:24:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.057 uVs 20:24:27 Integrated Voltage Measurement... 20:24:36 Voltage Offset Correction: v_off_ini = 2826.967 uV, v_off_fin = 2812.918 uV 20:24:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 164.926 uVs 20:24:39 I2Y Average and RMS of Measurements VT = -172.117 +- 4.481 uVs I2Y = -15.835 +- 0.412 uTm^2 20:24:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:24:47 Integrated Voltage Measurement... 20:24:56 Voltage Offset Correction: v_off_ini = 2837.193 uV, v_off_fin = 2845.164 uV 20:24:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -135.767 uVs 20:24:56 Integrated Voltage Measurement... 20:25:05 Voltage Offset Correction: v_off_ini = 2837.119 uV, v_off_fin = 2834.818 uV 20:25:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.571 uVs 20:25:05 Integrated Voltage Measurement... 20:25:14 Voltage Offset Correction: v_off_ini = 2829.087 uV, v_off_fin = 2822.477 uV 20:25:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -197.133 uVs 20:25:14 Integrated Voltage Measurement... 20:25:23 Voltage Offset Correction: v_off_ini = 2844.631 uV, v_off_fin = 2843.792 uV 20:25:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.382 uVs 20:25:23 Integrated Voltage Measurement... 20:25:32 Voltage Offset Correction: v_off_ini = 2832.941 uV, v_off_fin = 2823.211 uV 20:25:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.317 uVs 20:25:32 Integrated Voltage Measurement... 20:25:41 Voltage Offset Correction: v_off_ini = 2835.259 uV, v_off_fin = 2820.690 uV 20:25:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.544 uVs 20:25:45 I1X Average and RMS of Measurements VT = -162.619 +- 12.594 uVs I1X = 32.525 +- 2.519 uTm 20:25:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:25:52 Integrated Voltage Measurement... 20:26:01 Voltage Offset Correction: v_off_ini = 2810.844 uV, v_off_fin = 2799.928 uV 20:26:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.265 uVs 20:26:01 Integrated Voltage Measurement... 20:26:10 Voltage Offset Correction: v_off_ini = 2813.218 uV, v_off_fin = 2789.795 uV 20:26:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.621 uVs 20:26:10 Integrated Voltage Measurement... 20:26:19 Voltage Offset Correction: v_off_ini = 2784.020 uV, v_off_fin = 2806.724 uV 20:26:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.020 uVs 20:26:19 Integrated Voltage Measurement... 20:26:28 Voltage Offset Correction: v_off_ini = 2797.703 uV, v_off_fin = 2817.214 uV 20:26:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.165 uVs 20:26:28 Integrated Voltage Measurement... 20:26:37 Voltage Offset Correction: v_off_ini = 2813.594 uV, v_off_fin = 2806.947 uV 20:26:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.200 uVs 20:26:37 Integrated Voltage Measurement... 20:26:46 Voltage Offset Correction: v_off_ini = 2817.237 uV, v_off_fin = 2836.916 uV 20:26:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.308 uVs 20:26:50 I1Y Average and RMS of Measurements VT = -193.263 +- 8.371 uVs I1Y = -38.650 +- 1.673 uTm 20:26:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:26:55 Integrated Voltage Measurement... 20:27:04 Voltage Offset Correction: v_off_ini = 2812.637 uV, v_off_fin = 2809.245 uV 20:27:04 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -141.250 uVs 20:27:04 Integrated Voltage Measurement... 20:27:13 Voltage Offset Correction: v_off_ini = 2823.017 uV, v_off_fin = 2829.437 uV 20:27:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 138.025 uVs 20:27:13 Integrated Voltage Measurement... 20:27:22 Voltage Offset Correction: v_off_ini = 2809.515 uV, v_off_fin = 2813.404 uV 20:27:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.057 uVs 20:27:22 Integrated Voltage Measurement... 20:27:31 Voltage Offset Correction: v_off_ini = 2819.563 uV, v_off_fin = 2818.494 uV 20:27:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.576 uVs 20:27:31 Integrated Voltage Measurement... 20:27:40 Voltage Offset Correction: v_off_ini = 2818.061 uV, v_off_fin = 2804.263 uV 20:27:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.027 uVs 20:27:40 Integrated Voltage Measurement... 20:27:49 Voltage Offset Correction: v_off_ini = 2818.743 uV, v_off_fin = 2818.307 uV 20:27:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.832 uVs 20:27:52 I2X Average and RMS of Measurements VT = -137.961 +- 5.284 uVs I2X = 12.692 +- 0.486 uTm^2 20:27:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:27:57 Integrated Voltage Measurement... 20:28:06 Voltage Offset Correction: v_off_ini = 2825.742 uV, v_off_fin = 2820.397 uV 20:28:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -159.224 uVs 20:28:06 Integrated Voltage Measurement... 20:28:15 Voltage Offset Correction: v_off_ini = 2813.451 uV, v_off_fin = 2838.106 uV 20:28:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.095 uVs 20:28:15 Integrated Voltage Measurement... 20:28:24 Voltage Offset Correction: v_off_ini = 2840.214 uV, v_off_fin = 2822.585 uV 20:28:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.443 uVs 20:28:24 Integrated Voltage Measurement... 20:28:33 Voltage Offset Correction: v_off_ini = 2847.449 uV, v_off_fin = 2847.104 uV 20:28:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.127 uVs 20:28:33 Integrated Voltage Measurement... 20:28:42 Voltage Offset Correction: v_off_ini = 2837.316 uV, v_off_fin = 2824.227 uV 20:28:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.989 uVs 20:28:42 Integrated Voltage Measurement... 20:28:51 Voltage Offset Correction: v_off_ini = 2821.472 uV, v_off_fin = 2809.614 uV 20:28:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 161.906 uVs 20:28:53 I2Y Average and RMS of Measurements VT = -169.631 +- 2.939 uVs I2Y = -15.606 +- 0.270 uTm^2 20:28:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:29:01 Integrated Voltage Measurement... 20:29:10 Voltage Offset Correction: v_off_ini = 2818.509 uV, v_off_fin = 2806.699 uV 20:29:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -167.369 uVs 20:29:10 Integrated Voltage Measurement... 20:29:19 Voltage Offset Correction: v_off_ini = 2820.569 uV, v_off_fin = 2821.014 uV 20:29:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.610 uVs 20:29:19 Integrated Voltage Measurement... 20:29:28 Voltage Offset Correction: v_off_ini = 2790.622 uV, v_off_fin = 2802.985 uV 20:29:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.623 uVs 20:29:28 Integrated Voltage Measurement... 20:29:37 Voltage Offset Correction: v_off_ini = 2820.470 uV, v_off_fin = 2825.111 uV 20:29:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 163.888 uVs 20:29:37 Integrated Voltage Measurement... 20:29:46 Voltage Offset Correction: v_off_ini = 2801.939 uV, v_off_fin = 2796.352 uV 20:29:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -186.843 uVs 20:29:46 Integrated Voltage Measurement... 20:29:55 Voltage Offset Correction: v_off_ini = 2803.786 uV, v_off_fin = 2819.572 uV 20:29:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 174.742 uVs 20:30:00 I1X Average and RMS of Measurements VT = -170.179 +- 8.910 uVs I1X = 34.038 +- 1.782 uTm 20:30:02 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:30:06 Integrated Voltage Measurement... 20:30:15 Voltage Offset Correction: v_off_ini = 2825.605 uV, v_off_fin = 2823.178 uV 20:30:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.847 uVs 20:30:15 Integrated Voltage Measurement... 20:30:24 Voltage Offset Correction: v_off_ini = 2840.167 uV, v_off_fin = 2828.629 uV 20:30:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.666 uVs 20:30:24 Integrated Voltage Measurement... 20:30:33 Voltage Offset Correction: v_off_ini = 2831.326 uV, v_off_fin = 2815.904 uV 20:30:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.043 uVs 20:30:33 Integrated Voltage Measurement... 20:30:42 Voltage Offset Correction: v_off_ini = 2815.423 uV, v_off_fin = 2814.022 uV 20:30:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 191.657 uVs 20:30:42 Integrated Voltage Measurement... 20:30:51 Voltage Offset Correction: v_off_ini = 2814.343 uV, v_off_fin = 2812.216 uV 20:30:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.114 uVs 20:30:51 Integrated Voltage Measurement... 20:31:00 Voltage Offset Correction: v_off_ini = 2837.840 uV, v_off_fin = 2822.624 uV 20:31:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.031 uVs 20:31:05 I1Y Average and RMS of Measurements VT = -183.560 +- 3.508 uVs I1Y = -36.709 +- 0.702 uTm 20:31:07 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:31:10 Integrated Voltage Measurement... 20:31:19 Voltage Offset Correction: v_off_ini = 2834.451 uV, v_off_fin = 2824.913 uV 20:31:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.212 uVs 20:31:19 Integrated Voltage Measurement... 20:31:28 Voltage Offset Correction: v_off_ini = 2817.482 uV, v_off_fin = 2837.424 uV 20:31:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.645 uVs 20:31:28 Integrated Voltage Measurement... 20:31:37 Voltage Offset Correction: v_off_ini = 2828.152 uV, v_off_fin = 2810.449 uV 20:31:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.757 uVs 20:31:37 Integrated Voltage Measurement... 20:31:46 Voltage Offset Correction: v_off_ini = 2825.117 uV, v_off_fin = 2842.775 uV 20:31:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.030 uVs 20:31:46 Integrated Voltage Measurement... 20:31:55 Voltage Offset Correction: v_off_ini = 2840.216 uV, v_off_fin = 2815.379 uV 20:31:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.902 uVs 20:31:55 Integrated Voltage Measurement... 20:32:04 Voltage Offset Correction: v_off_ini = 2837.477 uV, v_off_fin = 2843.137 uV 20:32:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.682 uVs 20:32:06 I2X Average and RMS of Measurements VT = -128.705 +- 6.961 uVs I2X = 11.841 +- 0.640 uTm^2 20:32:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:32:11 Integrated Voltage Measurement... 20:32:20 Voltage Offset Correction: v_off_ini = 2789.752 uV, v_off_fin = 2802.211 uV 20:32:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.458 uVs 20:32:20 Integrated Voltage Measurement... 20:32:29 Voltage Offset Correction: v_off_ini = 2803.918 uV, v_off_fin = 2810.333 uV 20:32:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 156.971 uVs 20:32:29 Integrated Voltage Measurement... 20:32:38 Voltage Offset Correction: v_off_ini = 2805.517 uV, v_off_fin = 2797.339 uV 20:32:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -149.522 uVs 20:32:38 Integrated Voltage Measurement... 20:32:47 Voltage Offset Correction: v_off_ini = 2808.549 uV, v_off_fin = 2814.359 uV 20:32:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.140 uVs 20:32:47 Integrated Voltage Measurement... 20:32:56 Voltage Offset Correction: v_off_ini = 2824.673 uV, v_off_fin = 2831.925 uV 20:32:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.708 uVs 20:32:56 Integrated Voltage Measurement... 20:33:05 Voltage Offset Correction: v_off_ini = 2832.098 uV, v_off_fin = 2832.182 uV 20:33:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.093 uVs 20:33:08 I2Y Average and RMS of Measurements VT = -167.315 +- 9.166 uVs I2Y = -15.393 +- 0.843 uTm^2 20:33:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:33:29 Integrated Voltage Measurement... 20:33:38 Voltage Offset Correction: v_off_ini = 2838.124 uV, v_off_fin = 2810.535 uV 20:33:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -187.115 uVs 20:33:38 Integrated Voltage Measurement... 20:33:47 Voltage Offset Correction: v_off_ini = 2819.726 uV, v_off_fin = 2820.990 uV 20:33:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.130 uVs 20:33:47 Integrated Voltage Measurement... 20:33:56 Voltage Offset Correction: v_off_ini = 2809.012 uV, v_off_fin = 2826.154 uV 20:33:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -185.426 uVs 20:33:56 Integrated Voltage Measurement... 20:34:05 Voltage Offset Correction: v_off_ini = 2863.478 uV, v_off_fin = 2858.465 uV 20:34:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.116 uVs 20:34:05 Integrated Voltage Measurement... 20:34:14 Voltage Offset Correction: v_off_ini = 2836.178 uV, v_off_fin = 2817.490 uV 20:34:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -211.594 uVs 20:34:14 Integrated Voltage Measurement... 20:34:23 Voltage Offset Correction: v_off_ini = 2834.139 uV, v_off_fin = 2825.818 uV 20:34:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 200.725 uVs 20:34:27 I1X Average and RMS of Measurements VT = -179.351 +- 19.096 uVs I1X = 35.873 +- 3.818 uTm 20:34:30 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:34:34 Integrated Voltage Measurement... 20:34:43 Voltage Offset Correction: v_off_ini = 2813.924 uV, v_off_fin = 2791.766 uV 20:34:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -157.061 uVs 20:34:43 Integrated Voltage Measurement... 20:34:52 Voltage Offset Correction: v_off_ini = 2823.362 uV, v_off_fin = 2825.398 uV 20:34:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.568 uVs 20:34:52 Integrated Voltage Measurement... 20:35:01 Voltage Offset Correction: v_off_ini = 2818.970 uV, v_off_fin = 2810.680 uV 20:35:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.854 uVs 20:35:01 Integrated Voltage Measurement... 20:35:10 Voltage Offset Correction: v_off_ini = 2810.886 uV, v_off_fin = 2843.905 uV 20:35:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.384 uVs 20:35:10 Integrated Voltage Measurement... 20:35:19 Voltage Offset Correction: v_off_ini = 2841.715 uV, v_off_fin = 2818.011 uV 20:35:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -147.938 uVs 20:35:19 Integrated Voltage Measurement... 20:35:28 Voltage Offset Correction: v_off_ini = 2842.349 uV, v_off_fin = 2837.318 uV 20:35:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.838 uVs 20:35:32 I1Y Average and RMS of Measurements VT = -166.107 +- 9.355 uVs I1Y = -33.222 +- 1.871 uTm 20:35:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:35:40 Integrated Voltage Measurement... 20:35:49 Voltage Offset Correction: v_off_ini = 2845.203 uV, v_off_fin = 2819.756 uV 20:35:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -161.525 uVs 20:35:49 Integrated Voltage Measurement... 20:35:58 Voltage Offset Correction: v_off_ini = 2833.197 uV, v_off_fin = 2831.522 uV 20:35:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 149.074 uVs 20:35:58 Integrated Voltage Measurement... 20:36:07 Voltage Offset Correction: v_off_ini = 2831.892 uV, v_off_fin = 2820.411 uV 20:36:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -162.619 uVs 20:36:07 Integrated Voltage Measurement... 20:36:16 Voltage Offset Correction: v_off_ini = 2841.585 uV, v_off_fin = 2846.003 uV 20:36:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.928 uVs 20:36:16 Integrated Voltage Measurement... 20:36:25 Voltage Offset Correction: v_off_ini = 2844.983 uV, v_off_fin = 2832.976 uV 20:36:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -160.342 uVs 20:36:25 Integrated Voltage Measurement... 20:36:34 Voltage Offset Correction: v_off_ini = 2831.701 uV, v_off_fin = 2845.245 uV 20:36:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 162.713 uVs 20:36:37 I2X Average and RMS of Measurements VT = -158.700 +- 2.575 uVs I2X = 14.601 +- 0.237 uTm^2 20:36:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:36:44 Integrated Voltage Measurement... 20:36:53 Voltage Offset Correction: v_off_ini = 2834.891 uV, v_off_fin = 2821.255 uV 20:36:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.463 uVs 20:36:53 Integrated Voltage Measurement... 20:37:02 Voltage Offset Correction: v_off_ini = 2830.159 uV, v_off_fin = 2831.992 uV 20:37:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 141.361 uVs 20:37:02 Integrated Voltage Measurement... 20:37:11 Voltage Offset Correction: v_off_ini = 2817.691 uV, v_off_fin = 2823.266 uV 20:37:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -123.520 uVs 20:37:11 Integrated Voltage Measurement... 20:37:20 Voltage Offset Correction: v_off_ini = 2810.418 uV, v_off_fin = 2803.939 uV 20:37:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 139.993 uVs 20:37:20 Integrated Voltage Measurement... 20:37:29 Voltage Offset Correction: v_off_ini = 2789.549 uV, v_off_fin = 2794.320 uV 20:37:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -169.847 uVs 20:37:29 Integrated Voltage Measurement... 20:37:38 Voltage Offset Correction: v_off_ini = 2807.491 uV, v_off_fin = 2792.291 uV 20:37:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.499 uVs 20:37:41 I2Y Average and RMS of Measurements VT = -149.447 +- 15.830 uVs I2Y = -13.749 +- 1.457 uTm^2 20:37:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:37:50 Integrated Voltage Measurement... 20:37:59 Voltage Offset Correction: v_off_ini = 2762.174 uV, v_off_fin = 2772.113 uV 20:37:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -187.680 uVs 20:37:59 Integrated Voltage Measurement... 20:38:08 Voltage Offset Correction: v_off_ini = 2768.406 uV, v_off_fin = 2766.508 uV 20:38:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.375 uVs 20:38:08 Integrated Voltage Measurement... 20:38:17 Voltage Offset Correction: v_off_ini = 2751.959 uV, v_off_fin = 2759.878 uV 20:38:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -176.657 uVs 20:38:17 Integrated Voltage Measurement... 20:38:26 Voltage Offset Correction: v_off_ini = 2757.210 uV, v_off_fin = 2759.186 uV 20:38:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.089 uVs 20:38:26 Integrated Voltage Measurement... 20:38:35 Voltage Offset Correction: v_off_ini = 2742.583 uV, v_off_fin = 2730.981 uV 20:38:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.303 uVs 20:38:35 Integrated Voltage Measurement... 20:38:44 Voltage Offset Correction: v_off_ini = 2743.643 uV, v_off_fin = 2766.218 uV 20:38:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 178.643 uVs 20:38:48 I1X Average and RMS of Measurements VT = -175.624 +- 3.012 uVs I1X = 35.125 +- 0.602 uTm 20:38:50 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:38:55 Integrated Voltage Measurement... 20:39:03 Voltage Offset Correction: v_off_ini = 2750.768 uV, v_off_fin = 2740.088 uV 20:39:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.436 uVs 20:39:03 Integrated Voltage Measurement... 20:39:12 Voltage Offset Correction: v_off_ini = 2750.992 uV, v_off_fin = 2756.598 uV 20:39:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.602 uVs 20:39:12 Integrated Voltage Measurement... 20:39:21 Voltage Offset Correction: v_off_ini = 2753.055 uV, v_off_fin = 2762.112 uV 20:39:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.377 uVs 20:39:21 Integrated Voltage Measurement... 20:39:30 Voltage Offset Correction: v_off_ini = 2746.761 uV, v_off_fin = 2739.363 uV 20:39:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.209 uVs 20:39:30 Integrated Voltage Measurement... 20:39:39 Voltage Offset Correction: v_off_ini = 2722.406 uV, v_off_fin = 2749.279 uV 20:39:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.394 uVs 20:39:39 Integrated Voltage Measurement... 20:39:48 Voltage Offset Correction: v_off_ini = 2773.630 uV, v_off_fin = 2765.992 uV 20:39:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.837 uVs 20:39:53 I1Y Average and RMS of Measurements VT = -171.143 +- 6.977 uVs I1Y = -34.229 +- 1.395 uTm 20:39:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:40:00 Integrated Voltage Measurement... 20:40:09 Voltage Offset Correction: v_off_ini = 2768.946 uV, v_off_fin = 2748.381 uV 20:40:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -166.537 uVs 20:40:09 Integrated Voltage Measurement... 20:40:18 Voltage Offset Correction: v_off_ini = 2755.414 uV, v_off_fin = 2800.397 uV 20:40:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 177.845 uVs 20:40:18 Integrated Voltage Measurement... 20:40:27 Voltage Offset Correction: v_off_ini = 2756.234 uV, v_off_fin = 2727.363 uV 20:40:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -166.566 uVs 20:40:27 Integrated Voltage Measurement... 20:40:36 Voltage Offset Correction: v_off_ini = 2736.418 uV, v_off_fin = 2747.026 uV 20:40:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 163.423 uVs 20:40:36 Integrated Voltage Measurement... 20:40:45 Voltage Offset Correction: v_off_ini = 2746.882 uV, v_off_fin = 2746.699 uV 20:40:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.933 uVs 20:40:45 Integrated Voltage Measurement... 20:40:54 Voltage Offset Correction: v_off_ini = 2759.885 uV, v_off_fin = 2772.447 uV 20:40:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.191 uVs 20:40:57 I2X Average and RMS of Measurements VT = -164.582 +- 6.387 uVs I2X = 15.142 +- 0.588 uTm^2 20:41:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:41:05 Integrated Voltage Measurement... 20:41:13 Voltage Offset Correction: v_off_ini = 2782.088 uV, v_off_fin = 2761.771 uV 20:41:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.954 uVs 20:41:14 Integrated Voltage Measurement... 20:41:23 Voltage Offset Correction: v_off_ini = 2748.972 uV, v_off_fin = 2754.827 uV 20:41:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.083 uVs 20:41:23 Integrated Voltage Measurement... 20:41:32 Voltage Offset Correction: v_off_ini = 2760.324 uV, v_off_fin = 2719.366 uV 20:41:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.984 uVs 20:41:32 Integrated Voltage Measurement... 20:41:41 Voltage Offset Correction: v_off_ini = 2735.268 uV, v_off_fin = 2739.974 uV 20:41:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.918 uVs 20:41:41 Integrated Voltage Measurement... 20:41:50 Voltage Offset Correction: v_off_ini = 2727.213 uV, v_off_fin = 2729.683 uV 20:41:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -152.099 uVs 20:41:50 Integrated Voltage Measurement... 20:41:59 Voltage Offset Correction: v_off_ini = 2744.793 uV, v_off_fin = 2745.090 uV 20:41:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.101 uVs 20:42:01 I2Y Average and RMS of Measurements VT = -166.190 +- 8.351 uVs I2Y = -15.289 +- 0.768 uTm^2 20:42:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:42:10 Integrated Voltage Measurement... 20:42:19 Voltage Offset Correction: v_off_ini = 2737.510 uV, v_off_fin = 2736.316 uV 20:42:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -174.080 uVs 20:42:19 Integrated Voltage Measurement... 20:42:28 Voltage Offset Correction: v_off_ini = 2721.217 uV, v_off_fin = 2728.240 uV 20:42:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 173.843 uVs 20:42:28 Integrated Voltage Measurement... 20:42:37 Voltage Offset Correction: v_off_ini = 2732.419 uV, v_off_fin = 2732.663 uV 20:42:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -210.464 uVs 20:42:37 Integrated Voltage Measurement... 20:42:46 Voltage Offset Correction: v_off_ini = 2725.252 uV, v_off_fin = 2733.857 uV 20:42:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 177.227 uVs 20:42:46 Integrated Voltage Measurement... 20:42:55 Voltage Offset Correction: v_off_ini = 2740.328 uV, v_off_fin = 2736.871 uV 20:42:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -216.223 uVs 20:42:55 Integrated Voltage Measurement... 20:43:04 Voltage Offset Correction: v_off_ini = 2716.533 uV, v_off_fin = 2713.060 uV 20:43:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 173.362 uVs 20:43:08 I1X Average and RMS of Measurements VT = -187.533 +- 9.604 uVs I1X = 37.510 +- 1.918 uTm 20:43:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:43:15 Integrated Voltage Measurement... 20:43:24 Voltage Offset Correction: v_off_ini = 2692.594 uV, v_off_fin = 2676.552 uV 20:43:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.843 uVs 20:43:24 Integrated Voltage Measurement... 20:43:33 Voltage Offset Correction: v_off_ini = 2688.288 uV, v_off_fin = 2692.397 uV 20:43:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.456 uVs 20:43:33 Integrated Voltage Measurement... 20:43:42 Voltage Offset Correction: v_off_ini = 2688.795 uV, v_off_fin = 2686.833 uV 20:43:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.472 uVs 20:43:42 Integrated Voltage Measurement... 20:43:51 Voltage Offset Correction: v_off_ini = 2701.665 uV, v_off_fin = 2710.051 uV 20:43:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.179 uVs 20:43:51 Integrated Voltage Measurement... 20:44:00 Voltage Offset Correction: v_off_ini = 2717.763 uV, v_off_fin = 2712.918 uV 20:44:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.728 uVs 20:44:00 Integrated Voltage Measurement... 20:44:09 Voltage Offset Correction: v_off_ini = 2698.597 uV, v_off_fin = 2685.651 uV 20:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.768 uVs 20:44:13 I1Y Average and RMS of Measurements VT = -174.908 +- 5.795 uVs I1Y = -34.982 +- 1.159 uTm 20:44:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:44:21 Integrated Voltage Measurement... 20:44:30 Voltage Offset Correction: v_off_ini = 2675.467 uV, v_off_fin = 2681.899 uV 20:44:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -180.088 uVs 20:44:30 Integrated Voltage Measurement... 20:44:39 Voltage Offset Correction: v_off_ini = 2691.462 uV, v_off_fin = 2690.687 uV 20:44:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.407 uVs 20:44:39 Integrated Voltage Measurement... 20:44:48 Voltage Offset Correction: v_off_ini = 2689.830 uV, v_off_fin = 2663.276 uV 20:44:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.550 uVs 20:44:48 Integrated Voltage Measurement... 20:44:57 Voltage Offset Correction: v_off_ini = 2687.522 uV, v_off_fin = 2695.870 uV 20:44:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.004 uVs 20:44:57 Integrated Voltage Measurement... 20:45:06 Voltage Offset Correction: v_off_ini = 2683.894 uV, v_off_fin = 2676.783 uV 20:45:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.005 uVs 20:45:06 Integrated Voltage Measurement... 20:45:15 Voltage Offset Correction: v_off_ini = 2699.743 uV, v_off_fin = 2699.279 uV 20:45:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 164.287 uVs 20:45:17 I2X Average and RMS of Measurements VT = -155.057 +- 6.946 uVs I2X = 14.265 +- 0.639 uTm^2 20:45:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:45:25 Integrated Voltage Measurement... 20:45:34 Voltage Offset Correction: v_off_ini = 2685.781 uV, v_off_fin = 2687.339 uV 20:45:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.478 uVs 20:45:34 Integrated Voltage Measurement... 20:45:43 Voltage Offset Correction: v_off_ini = 2684.840 uV, v_off_fin = 2683.639 uV 20:45:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.656 uVs 20:45:43 Integrated Voltage Measurement... 20:45:52 Voltage Offset Correction: v_off_ini = 2670.973 uV, v_off_fin = 2687.297 uV 20:45:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -173.168 uVs 20:45:52 Integrated Voltage Measurement... 20:46:01 Voltage Offset Correction: v_off_ini = 2693.626 uV, v_off_fin = 2688.933 uV 20:46:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 144.295 uVs 20:46:01 Integrated Voltage Measurement... 20:46:10 Voltage Offset Correction: v_off_ini = 2685.466 uV, v_off_fin = 2694.184 uV 20:46:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -195.798 uVs 20:46:10 Integrated Voltage Measurement... 20:46:19 Voltage Offset Correction: v_off_ini = 2694.805 uV, v_off_fin = 2677.509 uV 20:46:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 160.350 uVs 20:46:21 I2Y Average and RMS of Measurements VT = -171.458 +- 9.001 uVs I2Y = -15.774 +- 0.828 uTm^2 20:46:26 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:46:30 Integrated Voltage Measurement... 20:46:39 Voltage Offset Correction: v_off_ini = 2657.542 uV, v_off_fin = 2643.787 uV 20:46:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.906 uVs 20:46:39 Integrated Voltage Measurement... 20:46:48 Voltage Offset Correction: v_off_ini = 2641.882 uV, v_off_fin = 2687.663 uV 20:46:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.624 uVs 20:46:48 Integrated Voltage Measurement... 20:46:57 Voltage Offset Correction: v_off_ini = 2663.478 uV, v_off_fin = 2665.909 uV 20:46:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -153.092 uVs 20:46:57 Integrated Voltage Measurement... 20:47:06 Voltage Offset Correction: v_off_ini = 2672.294 uV, v_off_fin = 2668.216 uV 20:47:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.923 uVs 20:47:06 Integrated Voltage Measurement... 20:47:15 Voltage Offset Correction: v_off_ini = 2653.851 uV, v_off_fin = 2687.468 uV 20:47:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -193.617 uVs 20:47:15 Integrated Voltage Measurement... 20:47:24 Voltage Offset Correction: v_off_ini = 2700.268 uV, v_off_fin = 2683.464 uV 20:47:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 205.010 uVs 20:47:29 I1X Average and RMS of Measurements VT = -178.695 +- 14.838 uVs I1X = 35.740 +- 2.969 uTm 20:47:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:47:35 Integrated Voltage Measurement... 20:47:44 Voltage Offset Correction: v_off_ini = 2680.040 uV, v_off_fin = 2660.247 uV 20:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -186.616 uVs 20:47:44 Integrated Voltage Measurement... 20:47:53 Voltage Offset Correction: v_off_ini = 2671.178 uV, v_off_fin = 2690.238 uV 20:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.901 uVs 20:47:53 Integrated Voltage Measurement... 20:48:02 Voltage Offset Correction: v_off_ini = 2684.736 uV, v_off_fin = 2694.684 uV 20:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.846 uVs 20:48:02 Integrated Voltage Measurement... 20:48:11 Voltage Offset Correction: v_off_ini = 2683.245 uV, v_off_fin = 2699.733 uV 20:48:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.922 uVs 20:48:11 Integrated Voltage Measurement... 20:48:20 Voltage Offset Correction: v_off_ini = 2698.933 uV, v_off_fin = 2666.053 uV 20:48:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.355 uVs 20:48:20 Integrated Voltage Measurement... 20:48:29 Voltage Offset Correction: v_off_ini = 2670.614 uV, v_off_fin = 2669.968 uV 20:48:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.730 uVs 20:48:33 I1Y Average and RMS of Measurements VT = -182.562 +- 5.325 uVs I1Y = -36.514 +- 1.065 uTm 20:48:38 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:48:41 Integrated Voltage Measurement... 20:48:50 Voltage Offset Correction: v_off_ini = 2690.686 uV, v_off_fin = 2688.673 uV 20:48:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -163.611 uVs 20:48:50 Integrated Voltage Measurement... 20:48:59 Voltage Offset Correction: v_off_ini = 2676.468 uV, v_off_fin = 2698.013 uV 20:48:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.332 uVs 20:48:59 Integrated Voltage Measurement... 20:49:08 Voltage Offset Correction: v_off_ini = 2692.707 uV, v_off_fin = 2700.813 uV 20:49:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -138.400 uVs 20:49:08 Integrated Voltage Measurement... 20:49:17 Voltage Offset Correction: v_off_ini = 2718.762 uV, v_off_fin = 2711.054 uV 20:49:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.354 uVs 20:49:17 Integrated Voltage Measurement... 20:49:26 Voltage Offset Correction: v_off_ini = 2725.832 uV, v_off_fin = 2715.865 uV 20:49:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.979 uVs 20:49:26 Integrated Voltage Measurement... 20:49:35 Voltage Offset Correction: v_off_ini = 2733.506 uV, v_off_fin = 2742.380 uV 20:49:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.701 uVs 20:49:38 I2X Average and RMS of Measurements VT = -144.896 +- 11.146 uVs I2X = 13.330 +- 1.025 uTm^2 20:49:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:49:45 Integrated Voltage Measurement... 20:49:54 Voltage Offset Correction: v_off_ini = 2718.524 uV, v_off_fin = 2718.778 uV 20:49:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -164.263 uVs 20:49:54 Integrated Voltage Measurement... 20:50:03 Voltage Offset Correction: v_off_ini = 2752.719 uV, v_off_fin = 2731.507 uV 20:50:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.201 uVs 20:50:03 Integrated Voltage Measurement... 20:50:12 Voltage Offset Correction: v_off_ini = 2719.435 uV, v_off_fin = 2739.245 uV 20:50:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.953 uVs 20:50:12 Integrated Voltage Measurement... 20:50:21 Voltage Offset Correction: v_off_ini = 2725.426 uV, v_off_fin = 2720.874 uV 20:50:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.377 uVs 20:50:21 Integrated Voltage Measurement... 20:50:30 Voltage Offset Correction: v_off_ini = 2716.147 uV, v_off_fin = 2716.046 uV 20:50:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.034 uVs 20:50:30 Integrated Voltage Measurement... 20:50:39 Voltage Offset Correction: v_off_ini = 2704.433 uV, v_off_fin = 2725.928 uV 20:50:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.749 uVs 20:50:42 I2Y Average and RMS of Measurements VT = -182.096 +- 12.231 uVs I2Y = -16.753 +- 1.125 uTm^2 20:50:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:50:51 Integrated Voltage Measurement... 20:51:00 Voltage Offset Correction: v_off_ini = 2741.351 uV, v_off_fin = 2725.814 uV 20:51:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -163.656 uVs 20:51:00 Integrated Voltage Measurement... 20:51:09 Voltage Offset Correction: v_off_ini = 2739.010 uV, v_off_fin = 2748.384 uV 20:51:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.968 uVs 20:51:09 Integrated Voltage Measurement... 20:51:18 Voltage Offset Correction: v_off_ini = 2711.465 uV, v_off_fin = 2734.255 uV 20:51:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -175.463 uVs 20:51:18 Integrated Voltage Measurement... 20:51:27 Voltage Offset Correction: v_off_ini = 2731.128 uV, v_off_fin = 2722.632 uV 20:51:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.290 uVs 20:51:27 Integrated Voltage Measurement... 20:51:36 Voltage Offset Correction: v_off_ini = 2726.680 uV, v_off_fin = 2721.989 uV 20:51:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -204.113 uVs 20:51:36 Integrated Voltage Measurement... 20:51:45 Voltage Offset Correction: v_off_ini = 2738.368 uV, v_off_fin = 2737.124 uV 20:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 194.011 uVs 20:51:49 I1X Average and RMS of Measurements VT = -177.917 +- 15.310 uVs I1X = 35.586 +- 3.060 uTm 20:51:51 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:51:56 Integrated Voltage Measurement... 20:52:05 Voltage Offset Correction: v_off_ini = 2741.835 uV, v_off_fin = 2732.045 uV 20:52:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.055 uVs 20:52:05 Integrated Voltage Measurement... 20:52:14 Voltage Offset Correction: v_off_ini = 2752.339 uV, v_off_fin = 2754.131 uV 20:52:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.969 uVs 20:52:14 Integrated Voltage Measurement... 20:52:23 Voltage Offset Correction: v_off_ini = 2747.004 uV, v_off_fin = 2747.802 uV 20:52:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.157 uVs 20:52:23 Integrated Voltage Measurement... 20:52:32 Voltage Offset Correction: v_off_ini = 2759.837 uV, v_off_fin = 2765.286 uV 20:52:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.959 uVs 20:52:32 Integrated Voltage Measurement... 20:52:41 Voltage Offset Correction: v_off_ini = 2755.032 uV, v_off_fin = 2762.483 uV 20:52:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.144 uVs 20:52:41 Integrated Voltage Measurement... 20:52:50 Voltage Offset Correction: v_off_ini = 2759.987 uV, v_off_fin = 2783.365 uV 20:52:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.557 uVs 20:52:54 I1Y Average and RMS of Measurements VT = -202.973 +- 18.447 uVs I1Y = -40.595 +- 3.689 uTm 20:52:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:53:02 Integrated Voltage Measurement... 20:53:11 Voltage Offset Correction: v_off_ini = 2765.980 uV, v_off_fin = 2778.428 uV 20:53:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.205 uVs 20:53:11 Integrated Voltage Measurement... 20:53:20 Voltage Offset Correction: v_off_ini = 2771.339 uV, v_off_fin = 2788.334 uV 20:53:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.604 uVs 20:53:20 Integrated Voltage Measurement... 20:53:29 Voltage Offset Correction: v_off_ini = 2779.469 uV, v_off_fin = 2778.274 uV 20:53:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.415 uVs 20:53:29 Integrated Voltage Measurement... 20:53:38 Voltage Offset Correction: v_off_ini = 2789.452 uV, v_off_fin = 2786.757 uV 20:53:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.675 uVs 20:53:38 Integrated Voltage Measurement... 20:53:47 Voltage Offset Correction: v_off_ini = 2791.383 uV, v_off_fin = 2778.986 uV 20:53:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -133.590 uVs 20:53:47 Integrated Voltage Measurement... 20:53:56 Voltage Offset Correction: v_off_ini = 2770.722 uV, v_off_fin = 2764.236 uV 20:53:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 158.390 uVs 20:53:58 I2X Average and RMS of Measurements VT = -141.980 +- 4.369 uVs I2X = 13.063 +- 0.402 uTm^2 20:54:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:54:06 Integrated Voltage Measurement... 20:54:15 Voltage Offset Correction: v_off_ini = 2766.180 uV, v_off_fin = 2748.355 uV 20:54:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.792 uVs 20:54:15 Integrated Voltage Measurement... 20:54:24 Voltage Offset Correction: v_off_ini = 2751.501 uV, v_off_fin = 2769.095 uV 20:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.625 uVs 20:54:24 Integrated Voltage Measurement... 20:54:33 Voltage Offset Correction: v_off_ini = 2764.630 uV, v_off_fin = 2761.837 uV 20:54:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -169.373 uVs 20:54:33 Integrated Voltage Measurement... 20:54:42 Voltage Offset Correction: v_off_ini = 2749.993 uV, v_off_fin = 2757.172 uV 20:54:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.524 uVs 20:54:42 Integrated Voltage Measurement... 20:54:51 Voltage Offset Correction: v_off_ini = 2749.925 uV, v_off_fin = 2765.226 uV 20:54:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.359 uVs 20:54:51 Integrated Voltage Measurement... 20:55:00 Voltage Offset Correction: v_off_ini = 2767.652 uV, v_off_fin = 2774.690 uV 20:55:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.357 uVs 20:55:02 I2Y Average and RMS of Measurements VT = -181.172 +- 2.976 uVs I2Y = -16.668 +- 0.274 uTm^2 20:55:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:55:14 Integrated Voltage Measurement... 20:55:23 Voltage Offset Correction: v_off_ini = 2773.536 uV, v_off_fin = 2751.405 uV 20:55:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -188.934 uVs 20:55:23 Integrated Voltage Measurement... 20:55:32 Voltage Offset Correction: v_off_ini = 2742.060 uV, v_off_fin = 2753.322 uV 20:55:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 175.958 uVs 20:55:32 Integrated Voltage Measurement... 20:55:41 Voltage Offset Correction: v_off_ini = 2741.088 uV, v_off_fin = 2726.238 uV 20:55:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -174.039 uVs 20:55:41 Integrated Voltage Measurement... 20:55:50 Voltage Offset Correction: v_off_ini = 2736.273 uV, v_off_fin = 2757.665 uV 20:55:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 196.061 uVs 20:55:50 Integrated Voltage Measurement... 20:55:59 Voltage Offset Correction: v_off_ini = 2749.338 uV, v_off_fin = 2743.527 uV 20:55:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -188.138 uVs 20:55:59 Integrated Voltage Measurement... 20:56:08 Voltage Offset Correction: v_off_ini = 2736.642 uV, v_off_fin = 2749.164 uV 20:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 192.691 uVs 20:56:12 I1X Average and RMS of Measurements VT = -185.970 +- 3.318 uVs I1X = 37.197 +- 0.665 uTm 20:56:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:56:19 Integrated Voltage Measurement... 20:56:28 Voltage Offset Correction: v_off_ini = 2767.431 uV, v_off_fin = 2748.215 uV 20:56:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.022 uVs 20:56:28 Integrated Voltage Measurement... 20:56:37 Voltage Offset Correction: v_off_ini = 2748.460 uV, v_off_fin = 2755.565 uV 20:56:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.408 uVs 20:56:37 Integrated Voltage Measurement... 20:56:46 Voltage Offset Correction: v_off_ini = 2763.329 uV, v_off_fin = 2760.546 uV 20:56:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.836 uVs 20:56:46 Integrated Voltage Measurement... 20:56:55 Voltage Offset Correction: v_off_ini = 2766.001 uV, v_off_fin = 2771.176 uV 20:56:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.403 uVs 20:56:55 Integrated Voltage Measurement... 20:57:04 Voltage Offset Correction: v_off_ini = 2751.980 uV, v_off_fin = 2742.602 uV 20:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.566 uVs 20:57:04 Integrated Voltage Measurement... 20:57:13 Voltage Offset Correction: v_off_ini = 2762.399 uV, v_off_fin = 2748.875 uV 20:57:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.508 uVs 20:57:17 I1Y Average and RMS of Measurements VT = -193.457 +- 3.358 uVs I1Y = -38.691 +- 0.672 uTm 20:57:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:57:22 Integrated Voltage Measurement... 20:57:31 Voltage Offset Correction: v_off_ini = 2746.490 uV, v_off_fin = 2723.779 uV 20:57:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -152.071 uVs 20:57:31 Integrated Voltage Measurement... 20:57:40 Voltage Offset Correction: v_off_ini = 2765.326 uV, v_off_fin = 2769.956 uV 20:57:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.542 uVs 20:57:41 Integrated Voltage Measurement... 20:57:49 Voltage Offset Correction: v_off_ini = 2741.455 uV, v_off_fin = 2738.162 uV 20:57:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -174.269 uVs 20:57:50 Integrated Voltage Measurement... 20:57:59 Voltage Offset Correction: v_off_ini = 2724.031 uV, v_off_fin = 2743.947 uV 20:57:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.041 uVs 20:57:59 Integrated Voltage Measurement... 20:58:08 Voltage Offset Correction: v_off_ini = 2745.894 uV, v_off_fin = 2729.950 uV 20:58:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -173.054 uVs 20:58:08 Integrated Voltage Measurement... 20:58:17 Voltage Offset Correction: v_off_ini = 2783.594 uV, v_off_fin = 2778.477 uV 20:58:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 143.929 uVs 20:58:19 I2X Average and RMS of Measurements VT = -158.151 +- 7.903 uVs I2X = 14.551 +- 0.727 uTm^2 20:58:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:58:24 Integrated Voltage Measurement... 20:58:33 Voltage Offset Correction: v_off_ini = 2782.118 uV, v_off_fin = 2773.355 uV 20:58:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.764 uVs 20:58:33 Integrated Voltage Measurement... 20:58:42 Voltage Offset Correction: v_off_ini = 2772.227 uV, v_off_fin = 2749.479 uV 20:58:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.484 uVs 20:58:42 Integrated Voltage Measurement... 20:58:51 Voltage Offset Correction: v_off_ini = 2773.487 uV, v_off_fin = 2751.678 uV 20:58:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.067 uVs 20:58:51 Integrated Voltage Measurement... 20:59:00 Voltage Offset Correction: v_off_ini = 2754.895 uV, v_off_fin = 2745.750 uV 20:59:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 153.052 uVs 20:59:00 Integrated Voltage Measurement... 20:59:09 Voltage Offset Correction: v_off_ini = 2727.810 uV, v_off_fin = 2744.301 uV 20:59:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -173.671 uVs 20:59:09 Integrated Voltage Measurement... 20:59:18 Voltage Offset Correction: v_off_ini = 2748.899 uV, v_off_fin = 2741.257 uV 20:59:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 174.376 uVs 20:59:21 I2Y Average and RMS of Measurements VT = -175.402 +- 7.439 uVs I2Y = -16.137 +- 0.684 uTm^2 20:59:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:59:29 Integrated Voltage Measurement... 20:59:38 Voltage Offset Correction: v_off_ini = 2736.581 uV, v_off_fin = 2749.217 uV 20:59:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -199.090 uVs 20:59:38 Integrated Voltage Measurement... 20:59:47 Voltage Offset Correction: v_off_ini = 2742.392 uV, v_off_fin = 2761.432 uV 20:59:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 179.997 uVs 20:59:47 Integrated Voltage Measurement... 20:59:56 Voltage Offset Correction: v_off_ini = 2747.220 uV, v_off_fin = 2760.225 uV 20:59:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -168.943 uVs 20:59:56 Integrated Voltage Measurement... 21:00:05 Voltage Offset Correction: v_off_ini = 2730.129 uV, v_off_fin = 2748.749 uV 21:00:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 179.043 uVs 21:00:05 Integrated Voltage Measurement... 21:00:14 Voltage Offset Correction: v_off_ini = 2765.706 uV, v_off_fin = 2745.999 uV 21:00:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -141.659 uVs 21:00:14 Integrated Voltage Measurement... 21:00:23 Voltage Offset Correction: v_off_ini = 2732.404 uV, v_off_fin = 2720.606 uV 21:00:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 177.344 uVs 21:00:27 I1X Average and RMS of Measurements VT = -174.346 +- 12.267 uVs I1X = 34.870 +- 2.453 uTm 21:00:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:00:34 Integrated Voltage Measurement... 21:00:43 Voltage Offset Correction: v_off_ini = 2760.530 uV, v_off_fin = 2736.037 uV 21:00:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.463 uVs 21:00:43 Integrated Voltage Measurement... 21:00:52 Voltage Offset Correction: v_off_ini = 2733.841 uV, v_off_fin = 2746.751 uV 21:00:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.099 uVs 21:00:52 Integrated Voltage Measurement... 21:01:01 Voltage Offset Correction: v_off_ini = 2729.409 uV, v_off_fin = 2715.409 uV 21:01:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.866 uVs 21:01:01 Integrated Voltage Measurement... 21:01:10 Voltage Offset Correction: v_off_ini = 2707.961 uV, v_off_fin = 2746.965 uV 21:01:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.192 uVs 21:01:10 Integrated Voltage Measurement... 21:01:19 Voltage Offset Correction: v_off_ini = 2740.196 uV, v_off_fin = 2732.421 uV 21:01:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.051 uVs 21:01:19 Integrated Voltage Measurement... 21:01:28 Voltage Offset Correction: v_off_ini = 2736.905 uV, v_off_fin = 2732.104 uV 21:01:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.817 uVs 21:01:32 I1Y Average and RMS of Measurements VT = -180.248 +- 8.952 uVs I1Y = -36.050 +- 1.790 uTm 21:01:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:01:37 Integrated Voltage Measurement... 21:01:46 Voltage Offset Correction: v_off_ini = 2743.617 uV, v_off_fin = 2712.472 uV 21:01:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.094 uVs 21:01:46 Integrated Voltage Measurement... 21:01:55 Voltage Offset Correction: v_off_ini = 2702.452 uV, v_off_fin = 2708.952 uV 21:01:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.084 uVs 21:01:55 Integrated Voltage Measurement... 21:02:04 Voltage Offset Correction: v_off_ini = 2761.201 uV, v_off_fin = 2735.507 uV 21:02:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.006 uVs 21:02:04 Integrated Voltage Measurement... 21:02:13 Voltage Offset Correction: v_off_ini = 2703.827 uV, v_off_fin = 2728.018 uV 21:02:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 188.533 uVs 21:02:13 Integrated Voltage Measurement... 21:02:22 Voltage Offset Correction: v_off_ini = 2754.545 uV, v_off_fin = 2736.846 uV 21:02:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -167.248 uVs 21:02:22 Integrated Voltage Measurement... 21:02:31 Voltage Offset Correction: v_off_ini = 2750.379 uV, v_off_fin = 2738.247 uV 21:02:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.078 uVs 21:02:34 I2X Average and RMS of Measurements VT = -157.174 +- 6.237 uVs I2X = 14.460 +- 0.574 uTm^2 21:02:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:02:39 Integrated Voltage Measurement... 21:02:48 Voltage Offset Correction: v_off_ini = 2715.007 uV, v_off_fin = 2737.629 uV 21:02:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.859 uVs 21:02:48 Integrated Voltage Measurement... 21:02:57 Voltage Offset Correction: v_off_ini = 2750.505 uV, v_off_fin = 2736.770 uV 21:02:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.350 uVs 21:02:57 Integrated Voltage Measurement... 21:03:06 Voltage Offset Correction: v_off_ini = 2743.156 uV, v_off_fin = 2727.382 uV 21:03:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -161.813 uVs 21:03:06 Integrated Voltage Measurement... 21:03:15 Voltage Offset Correction: v_off_ini = 2735.542 uV, v_off_fin = 2750.547 uV 21:03:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 158.952 uVs 21:03:15 Integrated Voltage Measurement... 21:03:24 Voltage Offset Correction: v_off_ini = 2746.030 uV, v_off_fin = 2743.736 uV 21:03:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.233 uVs 21:03:24 Integrated Voltage Measurement... 21:03:33 Voltage Offset Correction: v_off_ini = 2745.554 uV, v_off_fin = 2724.994 uV 21:03:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 137.003 uVs 21:03:35 I2Y Average and RMS of Measurements VT = -169.868 +- 18.407 uVs I2Y = -15.628 +- 1.693 uTm^2 21:03:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:03:44 Integrated Voltage Measurement... 21:03:53 Voltage Offset Correction: v_off_ini = 2721.085 uV, v_off_fin = 2717.098 uV 21:03:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -175.422 uVs 21:03:53 Integrated Voltage Measurement... 21:04:02 Voltage Offset Correction: v_off_ini = 2712.808 uV, v_off_fin = 2749.782 uV 21:04:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 187.226 uVs 21:04:02 Integrated Voltage Measurement... 21:04:11 Voltage Offset Correction: v_off_ini = 2727.336 uV, v_off_fin = 2756.555 uV 21:04:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -180.511 uVs 21:04:11 Integrated Voltage Measurement... 21:04:20 Voltage Offset Correction: v_off_ini = 2747.097 uV, v_off_fin = 2745.515 uV 21:04:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.440 uVs 21:04:20 Integrated Voltage Measurement... 21:04:29 Voltage Offset Correction: v_off_ini = 2732.827 uV, v_off_fin = 2725.026 uV 21:04:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -191.581 uVs 21:04:29 Integrated Voltage Measurement... 21:04:38 Voltage Offset Correction: v_off_ini = 2729.192 uV, v_off_fin = 2728.247 uV 21:04:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 174.200 uVs 21:04:42 I1X Average and RMS of Measurements VT = -176.397 +- 8.101 uVs I1X = 35.281 +- 1.621 uTm 21:04:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:04:49 Integrated Voltage Measurement... 21:04:58 Voltage Offset Correction: v_off_ini = 2750.120 uV, v_off_fin = 2728.711 uV 21:04:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.061 uVs 21:04:58 Integrated Voltage Measurement... 21:05:07 Voltage Offset Correction: v_off_ini = 2736.989 uV, v_off_fin = 2753.229 uV 21:05:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.124 uVs 21:05:07 Integrated Voltage Measurement... 21:05:16 Voltage Offset Correction: v_off_ini = 2739.300 uV, v_off_fin = 2731.294 uV 21:05:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.111 uVs 21:05:16 Integrated Voltage Measurement... 21:05:25 Voltage Offset Correction: v_off_ini = 2726.007 uV, v_off_fin = 2756.801 uV 21:05:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.465 uVs 21:05:25 Integrated Voltage Measurement... 21:05:34 Voltage Offset Correction: v_off_ini = 2756.201 uV, v_off_fin = 2753.666 uV 21:05:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.502 uVs 21:05:34 Integrated Voltage Measurement... 21:05:43 Voltage Offset Correction: v_off_ini = 2759.335 uV, v_off_fin = 2774.448 uV 21:05:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.403 uVs 21:05:47 I1Y Average and RMS of Measurements VT = -172.278 +- 6.820 uVs I1Y = -34.456 +- 1.364 uTm 21:05:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:05:52 Integrated Voltage Measurement... 21:06:01 Voltage Offset Correction: v_off_ini = 2741.421 uV, v_off_fin = 2762.498 uV 21:06:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.820 uVs 21:06:01 Integrated Voltage Measurement... 21:06:10 Voltage Offset Correction: v_off_ini = 2781.888 uV, v_off_fin = 2809.182 uV 21:06:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.635 uVs 21:06:10 Integrated Voltage Measurement... 21:06:19 Voltage Offset Correction: v_off_ini = 2798.700 uV, v_off_fin = 2787.748 uV 21:06:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -171.871 uVs 21:06:19 Integrated Voltage Measurement... 21:06:28 Voltage Offset Correction: v_off_ini = 2775.829 uV, v_off_fin = 2782.068 uV 21:06:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.394 uVs 21:06:28 Integrated Voltage Measurement... 21:06:37 Voltage Offset Correction: v_off_ini = 2777.897 uV, v_off_fin = 2775.016 uV 21:06:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.810 uVs 21:06:37 Integrated Voltage Measurement... 21:06:46 Voltage Offset Correction: v_off_ini = 2758.550 uV, v_off_fin = 2780.529 uV 21:06:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 158.401 uVs 21:06:48 I2X Average and RMS of Measurements VT = -151.488 +- 4.332 uVs I2X = 13.937 +- 0.399 uTm^2 21:06:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:06:53 Integrated Voltage Measurement... 21:07:02 Voltage Offset Correction: v_off_ini = 2746.321 uV, v_off_fin = 2740.662 uV 21:07:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.218 uVs 21:07:02 Integrated Voltage Measurement... 21:07:11 Voltage Offset Correction: v_off_ini = 2751.400 uV, v_off_fin = 2760.913 uV 21:07:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.880 uVs 21:07:12 Integrated Voltage Measurement... 21:07:20 Voltage Offset Correction: v_off_ini = 2751.744 uV, v_off_fin = 2745.485 uV 21:07:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.270 uVs 21:07:21 Integrated Voltage Measurement... 21:07:29 Voltage Offset Correction: v_off_ini = 2748.231 uV, v_off_fin = 2763.582 uV 21:07:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 167.275 uVs 21:07:30 Integrated Voltage Measurement... 21:07:39 Voltage Offset Correction: v_off_ini = 2745.993 uV, v_off_fin = 2742.312 uV 21:07:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.608 uVs 21:07:39 Integrated Voltage Measurement... 21:07:48 Voltage Offset Correction: v_off_ini = 2733.444 uV, v_off_fin = 2762.768 uV 21:07:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.122 uVs 21:07:50 I2Y Average and RMS of Measurements VT = -176.062 +- 2.918 uVs I2Y = -16.198 +- 0.268 uTm^2 21:07:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:07:58 Integrated Voltage Measurement... 21:08:07 Voltage Offset Correction: v_off_ini = 2775.690 uV, v_off_fin = 2758.683 uV 21:08:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -176.166 uVs 21:08:07 Integrated Voltage Measurement... 21:08:16 Voltage Offset Correction: v_off_ini = 2744.234 uV, v_off_fin = 2768.382 uV 21:08:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.013 uVs 21:08:16 Integrated Voltage Measurement... 21:08:25 Voltage Offset Correction: v_off_ini = 2757.798 uV, v_off_fin = 2739.538 uV 21:08:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -202.905 uVs 21:08:25 Integrated Voltage Measurement... 21:08:34 Voltage Offset Correction: v_off_ini = 2741.569 uV, v_off_fin = 2728.690 uV 21:08:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.416 uVs 21:08:34 Integrated Voltage Measurement... 21:08:43 Voltage Offset Correction: v_off_ini = 2725.282 uV, v_off_fin = 2706.957 uV 21:08:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -172.622 uVs 21:08:43 Integrated Voltage Measurement... 21:08:52 Voltage Offset Correction: v_off_ini = 2719.207 uV, v_off_fin = 2720.449 uV 21:08:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.741 uVs 21:08:56 I1X Average and RMS of Measurements VT = -169.810 +- 9.971 uVs I1X = 33.963 +- 1.994 uTm 21:08:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:09:03 Integrated Voltage Measurement... 21:09:12 Voltage Offset Correction: v_off_ini = 2735.905 uV, v_off_fin = 2726.441 uV 21:09:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.255 uVs 21:09:12 Integrated Voltage Measurement... 21:09:21 Voltage Offset Correction: v_off_ini = 2732.953 uV, v_off_fin = 2744.961 uV 21:09:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.375 uVs 21:09:21 Integrated Voltage Measurement... 21:09:30 Voltage Offset Correction: v_off_ini = 2741.076 uV, v_off_fin = 2720.460 uV 21:09:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.441 uVs 21:09:30 Integrated Voltage Measurement... 21:09:39 Voltage Offset Correction: v_off_ini = 2729.992 uV, v_off_fin = 2730.126 uV 21:09:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 164.894 uVs 21:09:39 Integrated Voltage Measurement... 21:09:48 Voltage Offset Correction: v_off_ini = 2759.923 uV, v_off_fin = 2747.972 uV 21:09:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.300 uVs 21:09:48 Integrated Voltage Measurement... 21:09:57 Voltage Offset Correction: v_off_ini = 2723.661 uV, v_off_fin = 2734.791 uV 21:09:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 179.076 uVs 21:10:01 I1Y Average and RMS of Measurements VT = -173.224 +- 7.623 uVs I1Y = -34.643 +- 1.526 uTm 21:10:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:10:06 Integrated Voltage Measurement... 21:10:15 Voltage Offset Correction: v_off_ini = 2711.789 uV, v_off_fin = 2706.741 uV 21:10:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -154.391 uVs 21:10:15 Integrated Voltage Measurement... 21:10:24 Voltage Offset Correction: v_off_ini = 2711.093 uV, v_off_fin = 2704.475 uV 21:10:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.173 uVs 21:10:24 Integrated Voltage Measurement... 21:10:33 Voltage Offset Correction: v_off_ini = 2720.154 uV, v_off_fin = 2711.164 uV 21:10:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -160.325 uVs 21:10:34 Integrated Voltage Measurement... 21:10:42 Voltage Offset Correction: v_off_ini = 2708.926 uV, v_off_fin = 2739.683 uV 21:10:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.286 uVs 21:10:43 Integrated Voltage Measurement... 21:10:51 Voltage Offset Correction: v_off_ini = 2735.680 uV, v_off_fin = 2715.752 uV 21:10:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.344 uVs 21:10:52 Integrated Voltage Measurement... 21:11:01 Voltage Offset Correction: v_off_ini = 2749.769 uV, v_off_fin = 2735.399 uV 21:11:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.373 uVs 21:11:03 I2X Average and RMS of Measurements VT = -148.148 +- 5.082 uVs I2X = 13.629 +- 0.468 uTm^2 21:11:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:11:08 Integrated Voltage Measurement... 21:11:17 Voltage Offset Correction: v_off_ini = 2761.432 uV, v_off_fin = 2750.561 uV 21:11:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.863 uVs 21:11:17 Integrated Voltage Measurement... 21:11:26 Voltage Offset Correction: v_off_ini = 2743.891 uV, v_off_fin = 2726.691 uV 21:11:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.531 uVs 21:11:26 Integrated Voltage Measurement... 21:11:35 Voltage Offset Correction: v_off_ini = 2727.353 uV, v_off_fin = 2734.719 uV 21:11:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -149.224 uVs 21:11:35 Integrated Voltage Measurement... 21:11:44 Voltage Offset Correction: v_off_ini = 2748.644 uV, v_off_fin = 2740.478 uV 21:11:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.507 uVs 21:11:44 Integrated Voltage Measurement... 21:11:53 Voltage Offset Correction: v_off_ini = 2750.669 uV, v_off_fin = 2757.608 uV 21:11:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -164.909 uVs 21:11:53 Integrated Voltage Measurement... 21:12:02 Voltage Offset Correction: v_off_ini = 2732.290 uV, v_off_fin = 2734.950 uV 21:12:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.368 uVs 21:12:05 I2Y Average and RMS of Measurements VT = -167.900 +- 5.752 uVs I2Y = -15.447 +- 0.529 uTm^2 21:12:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:12:13 Integrated Voltage Measurement... 21:12:22 Voltage Offset Correction: v_off_ini = 2714.531 uV, v_off_fin = 2719.661 uV 21:12:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -208.643 uVs 21:12:22 Integrated Voltage Measurement... 21:12:31 Voltage Offset Correction: v_off_ini = 2741.330 uV, v_off_fin = 2743.874 uV 21:12:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.143 uVs 21:12:31 Integrated Voltage Measurement... 21:12:40 Voltage Offset Correction: v_off_ini = 2726.324 uV, v_off_fin = 2737.880 uV 21:12:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -170.472 uVs 21:12:40 Integrated Voltage Measurement... 21:12:49 Voltage Offset Correction: v_off_ini = 2710.064 uV, v_off_fin = 2725.624 uV 21:12:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 175.329 uVs 21:12:49 Integrated Voltage Measurement... 21:12:58 Voltage Offset Correction: v_off_ini = 2732.992 uV, v_off_fin = 2718.592 uV 21:12:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -173.989 uVs 21:12:58 Integrated Voltage Measurement... 21:13:07 Voltage Offset Correction: v_off_ini = 2723.983 uV, v_off_fin = 2743.398 uV 21:13:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 162.311 uVs 21:13:11 I1X Average and RMS of Measurements VT = -174.648 +- 6.144 uVs I1X = 34.931 +- 1.228 uTm 21:13:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:13:18 Integrated Voltage Measurement... 21:13:27 Voltage Offset Correction: v_off_ini = 2728.336 uV, v_off_fin = 2706.526 uV 21:13:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.865 uVs 21:13:27 Integrated Voltage Measurement... 21:13:36 Voltage Offset Correction: v_off_ini = 2754.751 uV, v_off_fin = 2758.013 uV 21:13:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.702 uVs 21:13:36 Integrated Voltage Measurement... 21:13:45 Voltage Offset Correction: v_off_ini = 2762.112 uV, v_off_fin = 2733.818 uV 21:13:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.938 uVs 21:13:45 Integrated Voltage Measurement... 21:13:54 Voltage Offset Correction: v_off_ini = 2776.621 uV, v_off_fin = 2753.166 uV 21:13:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.152 uVs 21:13:54 Integrated Voltage Measurement... 21:14:03 Voltage Offset Correction: v_off_ini = 2751.589 uV, v_off_fin = 2741.830 uV 21:14:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -175.604 uVs 21:14:03 Integrated Voltage Measurement... 21:14:12 Voltage Offset Correction: v_off_ini = 2748.403 uV, v_off_fin = 2774.121 uV 21:14:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.940 uVs 21:14:16 I1Y Average and RMS of Measurements VT = -182.700 +- 9.156 uVs I1Y = -36.538 +- 1.830 uTm 21:14:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:14:21 Integrated Voltage Measurement... 21:14:30 Voltage Offset Correction: v_off_ini = 2736.901 uV, v_off_fin = 2744.309 uV 21:14:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.277 uVs 21:14:30 Integrated Voltage Measurement... 21:14:39 Voltage Offset Correction: v_off_ini = 2730.258 uV, v_off_fin = 2741.905 uV 21:14:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.029 uVs 21:14:39 Integrated Voltage Measurement... 21:14:48 Voltage Offset Correction: v_off_ini = 2762.415 uV, v_off_fin = 2745.487 uV 21:14:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.580 uVs 21:14:48 Integrated Voltage Measurement... 21:14:57 Voltage Offset Correction: v_off_ini = 2732.520 uV, v_off_fin = 2761.635 uV 21:14:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 168.265 uVs 21:14:57 Integrated Voltage Measurement... 21:15:06 Voltage Offset Correction: v_off_ini = 2759.977 uV, v_off_fin = 2748.270 uV 21:15:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -164.951 uVs 21:15:06 Integrated Voltage Measurement... 21:15:15 Voltage Offset Correction: v_off_ini = 2749.961 uV, v_off_fin = 2774.319 uV 21:15:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.172 uVs 21:15:17 I2X Average and RMS of Measurements VT = -147.046 +- 13.978 uVs I2X = 13.528 +- 1.286 uTm^2 21:15:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:15:23 Integrated Voltage Measurement... 21:15:31 Voltage Offset Correction: v_off_ini = 2769.021 uV, v_off_fin = 2792.468 uV 21:15:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -158.518 uVs 21:15:32 Integrated Voltage Measurement... 21:15:41 Voltage Offset Correction: v_off_ini = 2773.994 uV, v_off_fin = 2780.414 uV 21:15:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.183 uVs 21:15:41 Integrated Voltage Measurement... 21:15:50 Voltage Offset Correction: v_off_ini = 2759.390 uV, v_off_fin = 2762.199 uV 21:15:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.659 uVs 21:15:50 Integrated Voltage Measurement... 21:15:59 Voltage Offset Correction: v_off_ini = 2766.714 uV, v_off_fin = 2762.494 uV 21:15:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.655 uVs 21:15:59 Integrated Voltage Measurement... 21:16:08 Voltage Offset Correction: v_off_ini = 2773.866 uV, v_off_fin = 2769.670 uV 21:16:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.366 uVs 21:16:08 Integrated Voltage Measurement... 21:16:17 Voltage Offset Correction: v_off_ini = 2775.455 uV, v_off_fin = 2798.061 uV 21:16:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.100 uVs 21:16:19 I2Y Average and RMS of Measurements VT = -169.747 +- 12.696 uVs I2Y = -15.617 +- 1.168 uTm^2 21:16:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:16:40 Integrated Voltage Measurement... 21:16:49 Voltage Offset Correction: v_off_ini = 2784.419 uV, v_off_fin = 2759.523 uV 21:16:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -197.783 uVs 21:16:49 Integrated Voltage Measurement... 21:16:58 Voltage Offset Correction: v_off_ini = 2754.154 uV, v_off_fin = 2758.578 uV 21:16:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 180.832 uVs 21:16:58 Integrated Voltage Measurement... 21:17:07 Voltage Offset Correction: v_off_ini = 2753.890 uV, v_off_fin = 2749.484 uV 21:17:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.367 uVs 21:17:07 Integrated Voltage Measurement... 21:17:16 Voltage Offset Correction: v_off_ini = 2783.371 uV, v_off_fin = 2788.468 uV 21:17:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 163.274 uVs 21:17:16 Integrated Voltage Measurement... 21:17:25 Voltage Offset Correction: v_off_ini = 2781.438 uV, v_off_fin = 2770.205 uV 21:17:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -167.386 uVs 21:17:25 Integrated Voltage Measurement... 21:17:34 Voltage Offset Correction: v_off_ini = 2763.036 uV, v_off_fin = 2775.435 uV 21:17:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 180.558 uVs 21:17:39 I1X Average and RMS of Measurements VT = -175.867 +- 10.289 uVs I1X = 35.174 +- 2.059 uTm 21:17:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:17:45 Integrated Voltage Measurement... 21:17:54 Voltage Offset Correction: v_off_ini = 2789.576 uV, v_off_fin = 2780.051 uV 21:17:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.047 uVs 21:17:54 Integrated Voltage Measurement... 21:18:03 Voltage Offset Correction: v_off_ini = 2794.672 uV, v_off_fin = 2799.174 uV 21:18:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.312 uVs 21:18:03 Integrated Voltage Measurement... 21:18:12 Voltage Offset Correction: v_off_ini = 2797.237 uV, v_off_fin = 2790.022 uV 21:18:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.358 uVs 21:18:12 Integrated Voltage Measurement... 21:18:21 Voltage Offset Correction: v_off_ini = 2788.966 uV, v_off_fin = 2803.236 uV 21:18:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.685 uVs 21:18:21 Integrated Voltage Measurement... 21:18:30 Voltage Offset Correction: v_off_ini = 2772.243 uV, v_off_fin = 2764.373 uV 21:18:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.801 uVs 21:18:30 Integrated Voltage Measurement... 21:18:39 Voltage Offset Correction: v_off_ini = 2745.998 uV, v_off_fin = 2791.528 uV 21:18:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.340 uVs 21:18:43 I1Y Average and RMS of Measurements VT = -177.257 +- 3.237 uVs I1Y = -35.451 +- 0.647 uTm 21:18:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:18:51 Integrated Voltage Measurement... 21:19:00 Voltage Offset Correction: v_off_ini = 2795.756 uV, v_off_fin = 2780.995 uV 21:19:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -164.883 uVs 21:19:00 Integrated Voltage Measurement... 21:19:09 Voltage Offset Correction: v_off_ini = 2782.139 uV, v_off_fin = 2766.971 uV 21:19:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.761 uVs 21:19:09 Integrated Voltage Measurement... 21:19:18 Voltage Offset Correction: v_off_ini = 2764.877 uV, v_off_fin = 2763.729 uV 21:19:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.228 uVs 21:19:18 Integrated Voltage Measurement... 21:19:27 Voltage Offset Correction: v_off_ini = 2751.818 uV, v_off_fin = 2770.483 uV 21:19:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 161.478 uVs 21:19:27 Integrated Voltage Measurement... 21:19:36 Voltage Offset Correction: v_off_ini = 2755.836 uV, v_off_fin = 2742.456 uV 21:19:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.456 uVs 21:19:36 Integrated Voltage Measurement... 21:19:45 Voltage Offset Correction: v_off_ini = 2785.014 uV, v_off_fin = 2788.778 uV 21:19:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.221 uVs 21:19:48 I2X Average and RMS of Measurements VT = -153.171 +- 3.469 uVs I2X = 14.092 +- 0.319 uTm^2 21:19:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:19:55 Integrated Voltage Measurement... 21:20:04 Voltage Offset Correction: v_off_ini = 2777.500 uV, v_off_fin = 2769.495 uV 21:20:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -130.590 uVs 21:20:04 Integrated Voltage Measurement... 21:20:13 Voltage Offset Correction: v_off_ini = 2765.358 uV, v_off_fin = 2771.644 uV 21:20:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 122.435 uVs 21:20:13 Integrated Voltage Measurement... 21:20:22 Voltage Offset Correction: v_off_ini = 2773.166 uV, v_off_fin = 2783.092 uV 21:20:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.732 uVs 21:20:22 Integrated Voltage Measurement... 21:20:31 Voltage Offset Correction: v_off_ini = 2776.330 uV, v_off_fin = 2779.982 uV 21:20:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.577 uVs 21:20:31 Integrated Voltage Measurement... 21:20:40 Voltage Offset Correction: v_off_ini = 2768.427 uV, v_off_fin = 2764.895 uV 21:20:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -124.135 uVs 21:20:40 Integrated Voltage Measurement... 21:20:49 Voltage Offset Correction: v_off_ini = 2767.355 uV, v_off_fin = 2782.821 uV 21:20:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.564 uVs 21:20:52 I2Y Average and RMS of Measurements VT = -144.005 +- 15.730 uVs I2Y = -13.248 +- 1.447 uTm^2 21:20:56 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:21:01 Integrated Voltage Measurement... 21:21:10 Voltage Offset Correction: v_off_ini = 2805.662 uV, v_off_fin = 2798.077 uV 21:21:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -178.141 uVs 21:21:10 Integrated Voltage Measurement... 21:21:19 Voltage Offset Correction: v_off_ini = 2807.716 uV, v_off_fin = 2803.936 uV 21:21:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 163.261 uVs 21:21:19 Integrated Voltage Measurement... 21:21:28 Voltage Offset Correction: v_off_ini = 2766.837 uV, v_off_fin = 2762.949 uV 21:21:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -162.822 uVs 21:21:28 Integrated Voltage Measurement... 21:21:37 Voltage Offset Correction: v_off_ini = 2767.473 uV, v_off_fin = 2784.020 uV 21:21:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.027 uVs 21:21:37 Integrated Voltage Measurement... 21:21:46 Voltage Offset Correction: v_off_ini = 2773.933 uV, v_off_fin = 2772.742 uV 21:21:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.076 uVs 21:21:46 Integrated Voltage Measurement... 21:21:55 Voltage Offset Correction: v_off_ini = 2759.827 uV, v_off_fin = 2765.277 uV 21:21:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 172.626 uVs 21:21:59 I1X Average and RMS of Measurements VT = -166.325 +- 3.805 uVs I1X = 33.269 +- 0.763 uTm 21:22:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:22:06 Integrated Voltage Measurement... 21:22:15 Voltage Offset Correction: v_off_ini = 2771.701 uV, v_off_fin = 2747.547 uV 21:22:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.763 uVs 21:22:15 Integrated Voltage Measurement... 21:22:24 Voltage Offset Correction: v_off_ini = 2741.570 uV, v_off_fin = 2760.430 uV 21:22:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.755 uVs 21:22:24 Integrated Voltage Measurement... 21:22:33 Voltage Offset Correction: v_off_ini = 2745.635 uV, v_off_fin = 2733.010 uV 21:22:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.136 uVs 21:22:33 Integrated Voltage Measurement... 21:22:42 Voltage Offset Correction: v_off_ini = 2735.498 uV, v_off_fin = 2741.741 uV 21:22:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.851 uVs 21:22:42 Integrated Voltage Measurement... 21:22:51 Voltage Offset Correction: v_off_ini = 2735.804 uV, v_off_fin = 2735.238 uV 21:22:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.222 uVs 21:22:51 Integrated Voltage Measurement... 21:23:00 Voltage Offset Correction: v_off_ini = 2740.807 uV, v_off_fin = 2759.506 uV 21:23:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.639 uVs 21:23:04 I1Y Average and RMS of Measurements VT = -175.394 +- 5.181 uVs I1Y = -35.079 +- 1.036 uTm 21:23:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:23:11 Integrated Voltage Measurement... 21:23:20 Voltage Offset Correction: v_off_ini = 2742.524 uV, v_off_fin = 2708.509 uV 21:23:20 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -165.753 uVs 21:23:20 Integrated Voltage Measurement... 21:23:29 Voltage Offset Correction: v_off_ini = 2726.830 uV, v_off_fin = 2728.117 uV 21:23:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 172.326 uVs 21:23:29 Integrated Voltage Measurement... 21:23:38 Voltage Offset Correction: v_off_ini = 2744.998 uV, v_off_fin = 2735.699 uV 21:23:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.084 uVs 21:23:38 Integrated Voltage Measurement... 21:23:47 Voltage Offset Correction: v_off_ini = 2734.490 uV, v_off_fin = 2739.764 uV 21:23:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.336 uVs 21:23:47 Integrated Voltage Measurement... 21:23:56 Voltage Offset Correction: v_off_ini = 2716.682 uV, v_off_fin = 2735.201 uV 21:23:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -178.549 uVs 21:23:56 Integrated Voltage Measurement... 21:24:05 Voltage Offset Correction: v_off_ini = 2770.844 uV, v_off_fin = 2769.324 uV 21:24:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 129.685 uVs 21:24:08 I2X Average and RMS of Measurements VT = -154.956 +- 11.173 uVs I2X = 14.256 +- 1.028 uTm^2 21:24:13 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:24:15 Integrated Voltage Measurement... 21:24:24 Voltage Offset Correction: v_off_ini = 2755.258 uV, v_off_fin = 2757.828 uV 21:24:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -164.669 uVs 21:24:25 Integrated Voltage Measurement... 21:24:33 Voltage Offset Correction: v_off_ini = 2742.092 uV, v_off_fin = 2738.669 uV 21:24:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.573 uVs 21:24:34 Integrated Voltage Measurement... 21:24:42 Voltage Offset Correction: v_off_ini = 2760.538 uV, v_off_fin = 2763.228 uV 21:24:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -175.376 uVs 21:24:43 Integrated Voltage Measurement... 21:24:52 Voltage Offset Correction: v_off_ini = 2769.981 uV, v_off_fin = 2759.773 uV 21:24:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 146.962 uVs 21:24:52 Integrated Voltage Measurement... 21:25:01 Voltage Offset Correction: v_off_ini = 2763.328 uV, v_off_fin = 2751.328 uV 21:25:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -141.864 uVs 21:25:01 Integrated Voltage Measurement... 21:25:10 Voltage Offset Correction: v_off_ini = 2738.574 uV, v_off_fin = 2746.806 uV 21:25:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 153.409 uVs 21:25:12 I2Y Average and RMS of Measurements VT = -158.642 +- 8.153 uVs I2Y = -14.595 +- 0.750 uTm^2 21:25:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:25:21 Integrated Voltage Measurement... 21:25:30 Voltage Offset Correction: v_off_ini = 2749.073 uV, v_off_fin = 2745.190 uV 21:25:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -179.924 uVs 21:25:30 Integrated Voltage Measurement... 21:25:39 Voltage Offset Correction: v_off_ini = 2740.588 uV, v_off_fin = 2757.628 uV 21:25:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.273 uVs 21:25:39 Integrated Voltage Measurement... 21:25:48 Voltage Offset Correction: v_off_ini = 2750.617 uV, v_off_fin = 2758.175 uV 21:25:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.318 uVs 21:25:48 Integrated Voltage Measurement... 21:25:57 Voltage Offset Correction: v_off_ini = 2762.182 uV, v_off_fin = 2756.143 uV 21:25:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.072 uVs 21:25:57 Integrated Voltage Measurement... 21:26:06 Voltage Offset Correction: v_off_ini = 2771.361 uV, v_off_fin = 2769.721 uV 21:26:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.159 uVs 21:26:06 Integrated Voltage Measurement... 21:26:15 Voltage Offset Correction: v_off_ini = 2753.610 uV, v_off_fin = 2755.115 uV 21:26:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 171.757 uVs 21:26:19 I1X Average and RMS of Measurements VT = -161.417 +- 6.986 uVs I1X = 32.284 +- 1.397 uTm 21:26:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:26:26 Integrated Voltage Measurement... 21:26:35 Voltage Offset Correction: v_off_ini = 2742.165 uV, v_off_fin = 2756.993 uV 21:26:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.886 uVs 21:26:35 Integrated Voltage Measurement... 21:26:44 Voltage Offset Correction: v_off_ini = 2755.053 uV, v_off_fin = 2762.573 uV 21:26:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.310 uVs 21:26:44 Integrated Voltage Measurement... 21:26:53 Voltage Offset Correction: v_off_ini = 2752.069 uV, v_off_fin = 2746.140 uV 21:26:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.359 uVs 21:26:53 Integrated Voltage Measurement... 21:27:02 Voltage Offset Correction: v_off_ini = 2758.858 uV, v_off_fin = 2788.958 uV 21:27:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.772 uVs 21:27:02 Integrated Voltage Measurement... 21:27:11 Voltage Offset Correction: v_off_ini = 2776.638 uV, v_off_fin = 2766.320 uV 21:27:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.019 uVs 21:27:11 Integrated Voltage Measurement... 21:27:19 Voltage Offset Correction: v_off_ini = 2773.924 uV, v_off_fin = 2799.172 uV 21:27:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.800 uVs 21:27:24 I1Y Average and RMS of Measurements VT = -177.358 +- 5.209 uVs I1Y = -35.472 +- 1.042 uTm 21:27:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:27:31 Integrated Voltage Measurement... 21:27:40 Voltage Offset Correction: v_off_ini = 2784.241 uV, v_off_fin = 2779.084 uV 21:27:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.115 uVs 21:27:40 Integrated Voltage Measurement... 21:27:49 Voltage Offset Correction: v_off_ini = 2777.835 uV, v_off_fin = 2785.539 uV 21:27:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 148.057 uVs 21:27:49 Integrated Voltage Measurement... 21:27:58 Voltage Offset Correction: v_off_ini = 2793.035 uV, v_off_fin = 2777.687 uV 21:27:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -166.462 uVs 21:27:58 Integrated Voltage Measurement... 21:28:07 Voltage Offset Correction: v_off_ini = 2780.937 uV, v_off_fin = 2796.029 uV 21:28:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.487 uVs 21:28:07 Integrated Voltage Measurement... 21:28:16 Voltage Offset Correction: v_off_ini = 2787.676 uV, v_off_fin = 2777.738 uV 21:28:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -162.222 uVs 21:28:16 Integrated Voltage Measurement... 21:28:25 Voltage Offset Correction: v_off_ini = 2765.255 uV, v_off_fin = 2813.990 uV 21:28:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.992 uVs 21:28:28 I2X Average and RMS of Measurements VT = -145.723 +- 8.327 uVs I2X = 13.407 +- 0.766 uTm^2 21:28:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:28:36 Integrated Voltage Measurement... 21:28:44 Voltage Offset Correction: v_off_ini = 2797.377 uV, v_off_fin = 2789.984 uV 21:28:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.935 uVs 21:28:45 Integrated Voltage Measurement... 21:28:54 Voltage Offset Correction: v_off_ini = 2785.298 uV, v_off_fin = 2794.169 uV 21:28:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.965 uVs 21:28:54 Integrated Voltage Measurement... 21:29:03 Voltage Offset Correction: v_off_ini = 2768.798 uV, v_off_fin = 2776.951 uV 21:29:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.907 uVs 21:29:03 Integrated Voltage Measurement... 21:29:12 Voltage Offset Correction: v_off_ini = 2769.486 uV, v_off_fin = 2774.736 uV 21:29:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 156.118 uVs 21:29:12 Integrated Voltage Measurement... 21:29:21 Voltage Offset Correction: v_off_ini = 2765.889 uV, v_off_fin = 2754.468 uV 21:29:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -181.962 uVs 21:29:21 Integrated Voltage Measurement... 21:29:30 Voltage Offset Correction: v_off_ini = 2752.068 uV, v_off_fin = 2765.639 uV 21:29:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 166.252 uVs 21:29:32 I2Y Average and RMS of Measurements VT = -165.357 +- 6.238 uVs I2Y = -15.213 +- 0.574 uTm^2 21:29:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 21:29:41 Integrated Voltage Measurement... 21:29:50 Voltage Offset Correction: v_off_ini = 2777.270 uV, v_off_fin = 2760.248 uV 21:29:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -174.958 uVs 21:29:50 Integrated Voltage Measurement... 21:29:59 Voltage Offset Correction: v_off_ini = 2779.517 uV, v_off_fin = 2775.268 uV 21:29:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.426 uVs 21:29:59 Integrated Voltage Measurement... 21:30:08 Voltage Offset Correction: v_off_ini = 2770.709 uV, v_off_fin = 2755.294 uV 21:30:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.915 uVs 21:30:08 Integrated Voltage Measurement... 21:30:17 Voltage Offset Correction: v_off_ini = 2773.106 uV, v_off_fin = 2792.526 uV 21:30:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 175.553 uVs 21:30:17 Integrated Voltage Measurement... 21:30:26 Voltage Offset Correction: v_off_ini = 2783.815 uV, v_off_fin = 2795.990 uV 21:30:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -168.626 uVs 21:30:26 Integrated Voltage Measurement... 21:30:35 Voltage Offset Correction: v_off_ini = 2775.006 uV, v_off_fin = 2784.461 uV 21:30:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.058 uVs 21:30:39 I1X Average and RMS of Measurements VT = -164.923 +- 8.818 uVs I1X = 32.987 +- 1.762 uTm 21:30:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 21:30:46 Integrated Voltage Measurement... 21:30:55 Voltage Offset Correction: v_off_ini = 2754.116 uV, v_off_fin = 2742.343 uV 21:30:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.648 uVs 21:30:55 Integrated Voltage Measurement... 21:31:04 Voltage Offset Correction: v_off_ini = 2744.724 uV, v_off_fin = 2765.673 uV 21:31:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.265 uVs 21:31:04 Integrated Voltage Measurement... 21:31:13 Voltage Offset Correction: v_off_ini = 2741.935 uV, v_off_fin = 2770.241 uV 21:31:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.439 uVs 21:31:13 Integrated Voltage Measurement... 21:31:22 Voltage Offset Correction: v_off_ini = 2778.504 uV, v_off_fin = 2800.932 uV 21:31:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.619 uVs 21:31:22 Integrated Voltage Measurement... 21:31:31 Voltage Offset Correction: v_off_ini = 2777.115 uV, v_off_fin = 2755.824 uV 21:31:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.860 uVs 21:31:31 Integrated Voltage Measurement... 21:31:40 Voltage Offset Correction: v_off_ini = 2749.762 uV, v_off_fin = 2759.939 uV 21:31:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.498 uVs 21:31:44 I1Y Average and RMS of Measurements VT = -173.388 +- 9.369 uVs I1Y = -34.678 +- 1.874 uTm 21:31:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 21:31:51 Integrated Voltage Measurement... 21:32:00 Voltage Offset Correction: v_off_ini = 2779.105 uV, v_off_fin = 2770.472 uV 21:32:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -138.041 uVs 21:32:00 Integrated Voltage Measurement... 21:32:09 Voltage Offset Correction: v_off_ini = 2766.766 uV, v_off_fin = 2757.970 uV 21:32:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 165.655 uVs 21:32:09 Integrated Voltage Measurement... 21:32:18 Voltage Offset Correction: v_off_ini = 2781.746 uV, v_off_fin = 2772.334 uV 21:32:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.189 uVs 21:32:18 Integrated Voltage Measurement... 21:32:27 Voltage Offset Correction: v_off_ini = 2802.666 uV, v_off_fin = 2800.192 uV 21:32:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 134.229 uVs 21:32:27 Integrated Voltage Measurement... 21:32:36 Voltage Offset Correction: v_off_ini = 2801.678 uV, v_off_fin = 2788.544 uV 21:32:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.667 uVs 21:32:36 Integrated Voltage Measurement... 21:32:45 Voltage Offset Correction: v_off_ini = 2807.814 uV, v_off_fin = 2784.559 uV 21:32:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.913 uVs 21:32:48 I2X Average and RMS of Measurements VT = -142.616 +- 7.197 uVs I2X = 13.121 +- 0.662 uTm^2 21:32:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 21:32:56 Integrated Voltage Measurement... 21:33:04 Voltage Offset Correction: v_off_ini = 2787.329 uV, v_off_fin = 2792.941 uV 21:33:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.696 uVs 21:33:05 Integrated Voltage Measurement... 21:33:13 Voltage Offset Correction: v_off_ini = 2789.907 uV, v_off_fin = 2789.216 uV 21:33:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 174.594 uVs 21:33:14 Integrated Voltage Measurement... 21:33:23 Voltage Offset Correction: v_off_ini = 2805.051 uV, v_off_fin = 2793.519 uV 21:33:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.184 uVs 21:33:23 Integrated Voltage Measurement... 21:33:32 Voltage Offset Correction: v_off_ini = 2805.413 uV, v_off_fin = 2806.603 uV 21:33:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.214 uVs 21:33:32 Integrated Voltage Measurement... 21:33:41 Voltage Offset Correction: v_off_ini = 2809.527 uV, v_off_fin = 2799.683 uV 21:33:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.607 uVs 21:33:41 Integrated Voltage Measurement... 21:33:50 Voltage Offset Correction: v_off_ini = 2780.235 uV, v_off_fin = 2784.863 uV 21:33:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.771 uVs 21:33:52 I2Y Average and RMS of Measurements VT = -174.511 +- 6.862 uVs I2Y = -16.055 +- 0.631 uTm^2 21:33:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 21:34:01 Integrated Voltage Measurement... 21:34:10 Voltage Offset Correction: v_off_ini = 2824.210 uV, v_off_fin = 2809.155 uV 21:34:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -182.448 uVs 21:34:10 Integrated Voltage Measurement... 21:34:19 Voltage Offset Correction: v_off_ini = 2799.686 uV, v_off_fin = 2786.564 uV 21:34:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.184 uVs 21:34:19 Integrated Voltage Measurement... 21:34:28 Voltage Offset Correction: v_off_ini = 2784.225 uV, v_off_fin = 2782.159 uV 21:34:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -174.479 uVs 21:34:28 Integrated Voltage Measurement... 21:34:37 Voltage Offset Correction: v_off_ini = 2785.988 uV, v_off_fin = 2779.321 uV 21:34:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 173.916 uVs 21:34:37 Integrated Voltage Measurement... 21:34:46 Voltage Offset Correction: v_off_ini = 2793.309 uV, v_off_fin = 2794.555 uV 21:34:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.333 uVs 21:34:46 Integrated Voltage Measurement... 21:34:55 Voltage Offset Correction: v_off_ini = 2795.594 uV, v_off_fin = 2796.239 uV 21:34:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.593 uVs 21:34:59 I1X Average and RMS of Measurements VT = -178.159 +- 7.730 uVs I1X = 35.634 +- 1.546 uTm 21:35:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 21:35:06 Integrated Voltage Measurement... 21:35:15 Voltage Offset Correction: v_off_ini = 2773.311 uV, v_off_fin = 2781.840 uV 21:35:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.398 uVs 21:35:15 Integrated Voltage Measurement... 21:35:24 Voltage Offset Correction: v_off_ini = 2797.954 uV, v_off_fin = 2808.200 uV 21:35:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.441 uVs 21:35:24 Integrated Voltage Measurement... 21:35:33 Voltage Offset Correction: v_off_ini = 2791.324 uV, v_off_fin = 2789.116 uV 21:35:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.436 uVs 21:35:33 Integrated Voltage Measurement... 21:35:42 Voltage Offset Correction: v_off_ini = 2774.733 uV, v_off_fin = 2784.794 uV 21:35:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.941 uVs 21:35:42 Integrated Voltage Measurement... 21:35:51 Voltage Offset Correction: v_off_ini = 2808.866 uV, v_off_fin = 2769.920 uV 21:35:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.261 uVs 21:35:51 Integrated Voltage Measurement... 21:36:00 Voltage Offset Correction: v_off_ini = 2786.884 uV, v_off_fin = 2787.611 uV 21:36:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.051 uVs 21:36:04 I1Y Average and RMS of Measurements VT = -174.088 +- 3.899 uVs I1Y = -34.818 +- 0.780 uTm 21:36:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 21:36:12 Integrated Voltage Measurement... 21:36:21 Voltage Offset Correction: v_off_ini = 2796.496 uV, v_off_fin = 2783.067 uV 21:36:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.275 uVs 21:36:21 Integrated Voltage Measurement... 21:36:30 Voltage Offset Correction: v_off_ini = 2807.946 uV, v_off_fin = 2818.592 uV 21:36:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.546 uVs 21:36:30 Integrated Voltage Measurement... 21:36:39 Voltage Offset Correction: v_off_ini = 2800.759 uV, v_off_fin = 2811.381 uV 21:36:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.711 uVs 21:36:39 Integrated Voltage Measurement... 21:36:48 Voltage Offset Correction: v_off_ini = 2804.876 uV, v_off_fin = 2810.986 uV 21:36:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.110 uVs 21:36:48 Integrated Voltage Measurement... 21:36:57 Voltage Offset Correction: v_off_ini = 2816.402 uV, v_off_fin = 2796.997 uV 21:36:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.146 uVs 21:36:57 Integrated Voltage Measurement... 21:37:06 Voltage Offset Correction: v_off_ini = 2812.107 uV, v_off_fin = 2825.732 uV 21:37:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.577 uVs 21:37:08 I2X Average and RMS of Measurements VT = -137.061 +- 10.600 uVs I2X = 12.610 +- 0.975 uTm^2 21:37:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 21:37:16 Integrated Voltage Measurement... 21:37:25 Voltage Offset Correction: v_off_ini = 2799.216 uV, v_off_fin = 2801.059 uV 21:37:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -176.749 uVs 21:37:25 Integrated Voltage Measurement... 21:37:34 Voltage Offset Correction: v_off_ini = 2797.451 uV, v_off_fin = 2799.754 uV 21:37:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.670 uVs 21:37:34 Integrated Voltage Measurement... 21:37:43 Voltage Offset Correction: v_off_ini = 2816.495 uV, v_off_fin = 2816.269 uV 21:37:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.042 uVs 21:37:43 Integrated Voltage Measurement... 21:37:52 Voltage Offset Correction: v_off_ini = 2814.185 uV, v_off_fin = 2778.820 uV 21:37:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.403 uVs 21:37:52 Integrated Voltage Measurement... 21:38:01 Voltage Offset Correction: v_off_ini = 2797.243 uV, v_off_fin = 2779.316 uV 21:38:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.422 uVs 21:38:01 Integrated Voltage Measurement... 21:38:10 Voltage Offset Correction: v_off_ini = 2771.040 uV, v_off_fin = 2768.583 uV 21:38:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.726 uVs 21:38:12 I2Y Average and RMS of Measurements VT = -178.335 +- 4.340 uVs I2Y = -16.407 +- 0.399 uTm^2 21:38:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 21:38:24 Integrated Voltage Measurement... 21:38:33 Voltage Offset Correction: v_off_ini = 2809.391 uV, v_off_fin = 2773.617 uV 21:38:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -184.973 uVs 21:38:33 Integrated Voltage Measurement... 21:38:42 Voltage Offset Correction: v_off_ini = 2812.835 uV, v_off_fin = 2774.789 uV 21:38:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 173.793 uVs 21:38:42 Integrated Voltage Measurement... 21:38:51 Voltage Offset Correction: v_off_ini = 2810.585 uV, v_off_fin = 2802.504 uV 21:38:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -168.540 uVs 21:38:51 Integrated Voltage Measurement... 21:39:00 Voltage Offset Correction: v_off_ini = 2802.552 uV, v_off_fin = 2784.714 uV 21:39:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.364 uVs 21:39:00 Integrated Voltage Measurement... 21:39:09 Voltage Offset Correction: v_off_ini = 2802.007 uV, v_off_fin = 2781.161 uV 21:39:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.343 uVs 21:39:09 Integrated Voltage Measurement... 21:39:18 Voltage Offset Correction: v_off_ini = 2798.964 uV, v_off_fin = 2784.557 uV 21:39:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.345 uVs 21:39:22 I1X Average and RMS of Measurements VT = -168.060 +- 10.306 uVs I1X = 33.613 +- 2.061 uTm 21:39:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 21:39:29 Integrated Voltage Measurement... 21:39:38 Voltage Offset Correction: v_off_ini = 2802.179 uV, v_off_fin = 2796.134 uV 21:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.806 uVs 21:39:38 Integrated Voltage Measurement... 21:39:47 Voltage Offset Correction: v_off_ini = 2784.959 uV, v_off_fin = 2795.924 uV 21:39:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.928 uVs 21:39:47 Integrated Voltage Measurement... 21:39:56 Voltage Offset Correction: v_off_ini = 2822.315 uV, v_off_fin = 2795.056 uV 21:39:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.868 uVs 21:39:56 Integrated Voltage Measurement... 21:40:05 Voltage Offset Correction: v_off_ini = 2814.323 uV, v_off_fin = 2812.353 uV 21:40:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 154.313 uVs 21:40:05 Integrated Voltage Measurement... 21:40:14 Voltage Offset Correction: v_off_ini = 2796.858 uV, v_off_fin = 2793.462 uV 21:40:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.469 uVs 21:40:14 Integrated Voltage Measurement... 21:40:23 Voltage Offset Correction: v_off_ini = 2811.664 uV, v_off_fin = 2805.438 uV 21:40:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.137 uVs 21:40:27 I1Y Average and RMS of Measurements VT = -172.253 +- 2.558 uVs I1Y = -34.451 +- 0.512 uTm 21:40:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 21:40:32 Integrated Voltage Measurement... 21:40:41 Voltage Offset Correction: v_off_ini = 2767.532 uV, v_off_fin = 2775.320 uV 21:40:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -130.763 uVs 21:40:41 Integrated Voltage Measurement... 21:40:50 Voltage Offset Correction: v_off_ini = 2801.155 uV, v_off_fin = 2792.220 uV 21:40:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 167.257 uVs 21:40:50 Integrated Voltage Measurement... 21:40:59 Voltage Offset Correction: v_off_ini = 2786.877 uV, v_off_fin = 2782.036 uV 21:40:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -136.179 uVs 21:40:59 Integrated Voltage Measurement... 21:41:08 Voltage Offset Correction: v_off_ini = 2789.517 uV, v_off_fin = 2800.384 uV 21:41:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 150.906 uVs 21:41:08 Integrated Voltage Measurement... 21:41:17 Voltage Offset Correction: v_off_ini = 2783.277 uV, v_off_fin = 2780.114 uV 21:41:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.787 uVs 21:41:17 Integrated Voltage Measurement... 21:41:26 Voltage Offset Correction: v_off_ini = 2811.142 uV, v_off_fin = 2797.238 uV 21:41:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.312 uVs 21:41:29 I2X Average and RMS of Measurements VT = -147.201 +- 2.587 uVs I2X = 13.543 +- 0.237 uTm^2 21:41:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 21:41:34 Integrated Voltage Measurement... 21:41:43 Voltage Offset Correction: v_off_ini = 2798.547 uV, v_off_fin = 2787.855 uV 21:41:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.453 uVs 21:41:43 Integrated Voltage Measurement... 21:41:52 Voltage Offset Correction: v_off_ini = 2789.885 uV, v_off_fin = 2778.825 uV 21:41:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.933 uVs 21:41:52 Integrated Voltage Measurement... 21:42:01 Voltage Offset Correction: v_off_ini = 2770.114 uV, v_off_fin = 2762.755 uV 21:42:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.655 uVs 21:42:01 Integrated Voltage Measurement... 21:42:10 Voltage Offset Correction: v_off_ini = 2785.955 uV, v_off_fin = 2784.910 uV 21:42:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 150.082 uVs 21:42:10 Integrated Voltage Measurement... 21:42:19 Voltage Offset Correction: v_off_ini = 2768.610 uV, v_off_fin = 2795.957 uV 21:42:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.782 uVs 21:42:19 Integrated Voltage Measurement... 21:42:28 Voltage Offset Correction: v_off_ini = 2794.447 uV, v_off_fin = 2795.764 uV 21:42:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.150 uVs 21:42:30 I2Y Average and RMS of Measurements VT = -174.842 +- 10.247 uVs I2Y = -16.086 +- 0.943 uTm^2 21:42:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:42:39 Integrated Voltage Measurement... 21:42:48 Voltage Offset Correction: v_off_ini = 2765.023 uV, v_off_fin = 2748.969 uV 21:42:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.199 uVs 21:42:48 Integrated Voltage Measurement... 21:42:57 Voltage Offset Correction: v_off_ini = 2750.630 uV, v_off_fin = 2768.093 uV 21:42:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 198.053 uVs 21:42:57 Integrated Voltage Measurement... 21:43:06 Voltage Offset Correction: v_off_ini = 2776.331 uV, v_off_fin = 2793.891 uV 21:43:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -175.717 uVs 21:43:06 Integrated Voltage Measurement... 21:43:15 Voltage Offset Correction: v_off_ini = 2797.632 uV, v_off_fin = 2810.839 uV 21:43:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.063 uVs 21:43:15 Integrated Voltage Measurement... 21:43:24 Voltage Offset Correction: v_off_ini = 2778.809 uV, v_off_fin = 2772.994 uV 21:43:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -169.912 uVs 21:43:24 Integrated Voltage Measurement... 21:43:33 Voltage Offset Correction: v_off_ini = 2787.763 uV, v_off_fin = 2781.992 uV 21:43:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 139.109 uVs 21:43:37 I1X Average and RMS of Measurements VT = -167.176 +- 11.142 uVs I1X = 33.436 +- 2.227 uTm 21:43:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:43:44 Integrated Voltage Measurement... 21:43:53 Voltage Offset Correction: v_off_ini = 2810.958 uV, v_off_fin = 2801.566 uV 21:43:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.880 uVs 21:43:53 Integrated Voltage Measurement... 21:44:02 Voltage Offset Correction: v_off_ini = 2803.947 uV, v_off_fin = 2812.451 uV 21:44:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.019 uVs 21:44:02 Integrated Voltage Measurement... 21:44:11 Voltage Offset Correction: v_off_ini = 2810.726 uV, v_off_fin = 2779.828 uV 21:44:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.378 uVs 21:44:11 Integrated Voltage Measurement... 21:44:20 Voltage Offset Correction: v_off_ini = 2805.334 uV, v_off_fin = 2800.597 uV 21:44:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.315 uVs 21:44:20 Integrated Voltage Measurement... 21:44:29 Voltage Offset Correction: v_off_ini = 2800.319 uV, v_off_fin = 2787.637 uV 21:44:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.326 uVs 21:44:29 Integrated Voltage Measurement... 21:44:38 Voltage Offset Correction: v_off_ini = 2783.302 uV, v_off_fin = 2803.005 uV 21:44:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.769 uVs 21:44:42 I1Y Average and RMS of Measurements VT = -187.948 +- 2.490 uVs I1Y = -37.590 +- 0.498 uTm 21:44:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:44:47 Integrated Voltage Measurement... 21:44:56 Voltage Offset Correction: v_off_ini = 2802.700 uV, v_off_fin = 2786.039 uV 21:44:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.493 uVs 21:44:56 Integrated Voltage Measurement... 21:45:05 Voltage Offset Correction: v_off_ini = 2789.075 uV, v_off_fin = 2789.553 uV 21:45:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.649 uVs 21:45:05 Integrated Voltage Measurement... 21:45:14 Voltage Offset Correction: v_off_ini = 2789.181 uV, v_off_fin = 2768.589 uV 21:45:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.567 uVs 21:45:14 Integrated Voltage Measurement... 21:45:23 Voltage Offset Correction: v_off_ini = 2792.082 uV, v_off_fin = 2801.410 uV 21:45:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.099 uVs 21:45:23 Integrated Voltage Measurement... 21:45:32 Voltage Offset Correction: v_off_ini = 2801.819 uV, v_off_fin = 2773.292 uV 21:45:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.470 uVs 21:45:32 Integrated Voltage Measurement... 21:45:41 Voltage Offset Correction: v_off_ini = 2770.518 uV, v_off_fin = 2789.394 uV 21:45:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 150.194 uVs 21:45:44 I2X Average and RMS of Measurements VT = -141.412 +- 9.884 uVs I2X = 13.010 +- 0.910 uTm^2 21:45:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:45:49 Integrated Voltage Measurement... 21:45:58 Voltage Offset Correction: v_off_ini = 2766.847 uV, v_off_fin = 2772.716 uV 21:45:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.971 uVs 21:45:58 Integrated Voltage Measurement... 21:46:07 Voltage Offset Correction: v_off_ini = 2775.692 uV, v_off_fin = 2762.421 uV 21:46:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.938 uVs 21:46:07 Integrated Voltage Measurement... 21:46:16 Voltage Offset Correction: v_off_ini = 2771.278 uV, v_off_fin = 2772.708 uV 21:46:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -134.243 uVs 21:46:16 Integrated Voltage Measurement... 21:46:25 Voltage Offset Correction: v_off_ini = 2773.924 uV, v_off_fin = 2777.429 uV 21:46:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 166.383 uVs 21:46:25 Integrated Voltage Measurement... 21:46:34 Voltage Offset Correction: v_off_ini = 2790.095 uV, v_off_fin = 2783.679 uV 21:46:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -160.805 uVs 21:46:34 Integrated Voltage Measurement... 21:46:43 Voltage Offset Correction: v_off_ini = 2794.830 uV, v_off_fin = 2778.995 uV 21:46:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 153.009 uVs 21:46:45 I2Y Average and RMS of Measurements VT = -161.558 +- 11.558 uVs I2Y = -14.863 +- 1.063 uTm^2 21:46:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:46:54 Integrated Voltage Measurement... 21:47:03 Voltage Offset Correction: v_off_ini = 2788.997 uV, v_off_fin = 2782.216 uV 21:47:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -164.240 uVs 21:47:03 Integrated Voltage Measurement... 21:47:12 Voltage Offset Correction: v_off_ini = 2784.346 uV, v_off_fin = 2789.806 uV 21:47:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.830 uVs 21:47:12 Integrated Voltage Measurement... 21:47:21 Voltage Offset Correction: v_off_ini = 2791.467 uV, v_off_fin = 2788.826 uV 21:47:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -179.576 uVs 21:47:21 Integrated Voltage Measurement... 21:47:30 Voltage Offset Correction: v_off_ini = 2807.948 uV, v_off_fin = 2825.450 uV 21:47:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 179.328 uVs 21:47:30 Integrated Voltage Measurement... 21:47:39 Voltage Offset Correction: v_off_ini = 2780.977 uV, v_off_fin = 2791.633 uV 21:47:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -153.070 uVs 21:47:39 Integrated Voltage Measurement... 21:47:48 Voltage Offset Correction: v_off_ini = 2802.311 uV, v_off_fin = 2791.624 uV 21:47:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.889 uVs 21:47:52 I1X Average and RMS of Measurements VT = -167.489 +- 11.220 uVs I1X = 33.499 +- 2.245 uTm 21:47:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:47:59 Integrated Voltage Measurement... 21:48:07 Voltage Offset Correction: v_off_ini = 2799.973 uV, v_off_fin = 2776.258 uV 21:48:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -167.678 uVs 21:48:08 Integrated Voltage Measurement... 21:48:16 Voltage Offset Correction: v_off_ini = 2795.121 uV, v_off_fin = 2799.247 uV 21:48:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.908 uVs 21:48:17 Integrated Voltage Measurement... 21:48:25 Voltage Offset Correction: v_off_ini = 2782.583 uV, v_off_fin = 2784.653 uV 21:48:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.447 uVs 21:48:26 Integrated Voltage Measurement... 21:48:34 Voltage Offset Correction: v_off_ini = 2781.556 uV, v_off_fin = 2805.740 uV 21:48:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.429 uVs 21:48:35 Integrated Voltage Measurement... 21:48:43 Voltage Offset Correction: v_off_ini = 2795.768 uV, v_off_fin = 2791.802 uV 21:48:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.041 uVs 21:48:44 Integrated Voltage Measurement... 21:48:52 Voltage Offset Correction: v_off_ini = 2793.079 uV, v_off_fin = 2806.554 uV 21:48:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.842 uVs 21:48:57 I1Y Average and RMS of Measurements VT = -179.057 +- 5.453 uVs I1Y = -35.812 +- 1.090 uTm 21:48:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:49:02 Integrated Voltage Measurement... 21:49:11 Voltage Offset Correction: v_off_ini = 2813.503 uV, v_off_fin = 2799.136 uV 21:49:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -177.003 uVs 21:49:11 Integrated Voltage Measurement... 21:49:20 Voltage Offset Correction: v_off_ini = 2803.711 uV, v_off_fin = 2815.047 uV 21:49:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 159.498 uVs 21:49:20 Integrated Voltage Measurement... 21:49:29 Voltage Offset Correction: v_off_ini = 2804.021 uV, v_off_fin = 2788.438 uV 21:49:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.209 uVs 21:49:29 Integrated Voltage Measurement... 21:49:38 Voltage Offset Correction: v_off_ini = 2786.384 uV, v_off_fin = 2807.071 uV 21:49:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.347 uVs 21:49:38 Integrated Voltage Measurement... 21:49:47 Voltage Offset Correction: v_off_ini = 2801.680 uV, v_off_fin = 2793.671 uV 21:49:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.607 uVs 21:49:47 Integrated Voltage Measurement... 21:49:56 Voltage Offset Correction: v_off_ini = 2811.827 uV, v_off_fin = 2798.104 uV 21:49:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.345 uVs 21:49:58 I2X Average and RMS of Measurements VT = -154.335 +- 11.339 uVs I2X = 14.199 +- 1.043 uTm^2 21:50:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:50:03 Integrated Voltage Measurement... 21:50:12 Voltage Offset Correction: v_off_ini = 2793.855 uV, v_off_fin = 2792.572 uV 21:50:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -143.262 uVs 21:50:12 Integrated Voltage Measurement... 21:50:21 Voltage Offset Correction: v_off_ini = 2792.377 uV, v_off_fin = 2783.741 uV 21:50:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 165.788 uVs 21:50:21 Integrated Voltage Measurement... 21:50:30 Voltage Offset Correction: v_off_ini = 2779.463 uV, v_off_fin = 2785.318 uV 21:50:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -156.538 uVs 21:50:30 Integrated Voltage Measurement... 21:50:39 Voltage Offset Correction: v_off_ini = 2768.199 uV, v_off_fin = 2770.639 uV 21:50:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.215 uVs 21:50:39 Integrated Voltage Measurement... 21:50:48 Voltage Offset Correction: v_off_ini = 2783.518 uV, v_off_fin = 2784.556 uV 21:50:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.196 uVs 21:50:48 Integrated Voltage Measurement... 21:50:57 Voltage Offset Correction: v_off_ini = 2761.443 uV, v_off_fin = 2778.949 uV 21:50:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.931 uVs 21:51:00 I2Y Average and RMS of Measurements VT = -166.155 +- 12.850 uVs I2Y = -15.286 +- 1.182 uTm^2 21:51:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:51:08 Integrated Voltage Measurement... 21:51:17 Voltage Offset Correction: v_off_ini = 2784.002 uV, v_off_fin = 2757.782 uV 21:51:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -152.852 uVs 21:51:17 Integrated Voltage Measurement... 21:51:26 Voltage Offset Correction: v_off_ini = 2747.693 uV, v_off_fin = 2759.620 uV 21:51:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.032 uVs 21:51:26 Integrated Voltage Measurement... 21:51:35 Voltage Offset Correction: v_off_ini = 2780.258 uV, v_off_fin = 2751.646 uV 21:51:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -197.347 uVs 21:51:35 Integrated Voltage Measurement... 21:51:44 Voltage Offset Correction: v_off_ini = 2746.084 uV, v_off_fin = 2743.970 uV 21:51:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 180.704 uVs 21:51:44 Integrated Voltage Measurement... 21:51:53 Voltage Offset Correction: v_off_ini = 2753.856 uV, v_off_fin = 2740.366 uV 21:51:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.801 uVs 21:51:53 Integrated Voltage Measurement... 21:52:02 Voltage Offset Correction: v_off_ini = 2713.703 uV, v_off_fin = 2731.831 uV 21:52:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 197.184 uVs 21:52:06 I1X Average and RMS of Measurements VT = -173.487 +- 15.434 uVs I1X = 34.698 +- 3.086 uTm 21:52:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:52:13 Integrated Voltage Measurement... 21:52:22 Voltage Offset Correction: v_off_ini = 2701.752 uV, v_off_fin = 2699.767 uV 21:52:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.024 uVs 21:52:22 Integrated Voltage Measurement... 21:52:31 Voltage Offset Correction: v_off_ini = 2706.930 uV, v_off_fin = 2729.224 uV 21:52:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.028 uVs 21:52:31 Integrated Voltage Measurement... 21:52:40 Voltage Offset Correction: v_off_ini = 2715.134 uV, v_off_fin = 2711.759 uV 21:52:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.998 uVs 21:52:40 Integrated Voltage Measurement... 21:52:49 Voltage Offset Correction: v_off_ini = 2719.893 uV, v_off_fin = 2736.528 uV 21:52:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 179.156 uVs 21:52:49 Integrated Voltage Measurement... 21:52:58 Voltage Offset Correction: v_off_ini = 2717.776 uV, v_off_fin = 2708.408 uV 21:52:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.580 uVs 21:52:58 Integrated Voltage Measurement... 21:53:07 Voltage Offset Correction: v_off_ini = 2719.866 uV, v_off_fin = 2727.942 uV 21:53:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.517 uVs 21:53:11 I1Y Average and RMS of Measurements VT = -176.217 +- 4.493 uVs I1Y = -35.242 +- 0.897 uTm 21:53:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:53:16 Integrated Voltage Measurement... 21:53:25 Voltage Offset Correction: v_off_ini = 2721.051 uV, v_off_fin = 2718.363 uV 21:53:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.065 uVs 21:53:25 Integrated Voltage Measurement... 21:53:34 Voltage Offset Correction: v_off_ini = 2721.719 uV, v_off_fin = 2738.694 uV 21:53:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.035 uVs 21:53:34 Integrated Voltage Measurement... 21:53:43 Voltage Offset Correction: v_off_ini = 2714.368 uV, v_off_fin = 2695.199 uV 21:53:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.432 uVs 21:53:43 Integrated Voltage Measurement... 21:53:52 Voltage Offset Correction: v_off_ini = 2699.997 uV, v_off_fin = 2708.470 uV 21:53:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.594 uVs 21:53:53 Integrated Voltage Measurement... 21:54:01 Voltage Offset Correction: v_off_ini = 2680.176 uV, v_off_fin = 2677.564 uV 21:54:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.827 uVs 21:54:02 Integrated Voltage Measurement... 21:54:11 Voltage Offset Correction: v_off_ini = 2675.894 uV, v_off_fin = 2676.286 uV 21:54:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.395 uVs 21:54:13 I2X Average and RMS of Measurements VT = -140.558 +- 5.708 uVs I2X = 12.931 +- 0.525 uTm^2 21:54:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:54:18 Integrated Voltage Measurement... 21:54:27 Voltage Offset Correction: v_off_ini = 2679.016 uV, v_off_fin = 2670.299 uV 21:54:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.643 uVs 21:54:27 Integrated Voltage Measurement... 21:54:36 Voltage Offset Correction: v_off_ini = 2681.126 uV, v_off_fin = 2688.933 uV 21:54:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.242 uVs 21:54:36 Integrated Voltage Measurement... 21:54:45 Voltage Offset Correction: v_off_ini = 2674.258 uV, v_off_fin = 2671.173 uV 21:54:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -156.692 uVs 21:54:45 Integrated Voltage Measurement... 21:54:54 Voltage Offset Correction: v_off_ini = 2678.219 uV, v_off_fin = 2691.066 uV 21:54:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 152.713 uVs 21:54:54 Integrated Voltage Measurement... 21:55:03 Voltage Offset Correction: v_off_ini = 2687.574 uV, v_off_fin = 2695.339 uV 21:55:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -153.743 uVs 21:55:03 Integrated Voltage Measurement... 21:55:12 Voltage Offset Correction: v_off_ini = 2688.652 uV, v_off_fin = 2688.903 uV 21:55:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.170 uVs 21:55:15 I2Y Average and RMS of Measurements VT = -159.867 +- 5.176 uVs I2Y = -14.708 +- 0.476 uTm^2 21:55:19 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:55:23 Integrated Voltage Measurement... 21:55:32 Voltage Offset Correction: v_off_ini = 2692.650 uV, v_off_fin = 2674.538 uV 21:55:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -161.121 uVs 21:55:32 Integrated Voltage Measurement... 21:55:41 Voltage Offset Correction: v_off_ini = 2673.795 uV, v_off_fin = 2686.544 uV 21:55:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 169.743 uVs 21:55:41 Integrated Voltage Measurement... 21:55:50 Voltage Offset Correction: v_off_ini = 2672.869 uV, v_off_fin = 2674.495 uV 21:55:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.027 uVs 21:55:50 Integrated Voltage Measurement... 21:55:59 Voltage Offset Correction: v_off_ini = 2671.599 uV, v_off_fin = 2683.294 uV 21:55:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.519 uVs 21:55:59 Integrated Voltage Measurement... 21:56:08 Voltage Offset Correction: v_off_ini = 2679.367 uV, v_off_fin = 2675.411 uV 21:56:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.338 uVs 21:56:08 Integrated Voltage Measurement... 21:56:17 Voltage Offset Correction: v_off_ini = 2658.291 uV, v_off_fin = 2678.253 uV 21:56:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.932 uVs 21:56:21 I1X Average and RMS of Measurements VT = -162.947 +- 6.317 uVs I1X = 32.590 +- 1.263 uTm 21:56:24 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:56:28 Integrated Voltage Measurement... 21:56:37 Voltage Offset Correction: v_off_ini = 2658.062 uV, v_off_fin = 2658.575 uV 21:56:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.516 uVs 21:56:37 Integrated Voltage Measurement... 21:56:46 Voltage Offset Correction: v_off_ini = 2673.416 uV, v_off_fin = 2682.002 uV 21:56:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.918 uVs 21:56:46 Integrated Voltage Measurement... 21:56:55 Voltage Offset Correction: v_off_ini = 2684.966 uV, v_off_fin = 2687.238 uV 21:56:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.349 uVs 21:56:55 Integrated Voltage Measurement... 21:57:04 Voltage Offset Correction: v_off_ini = 2650.169 uV, v_off_fin = 2667.596 uV 21:57:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.761 uVs 21:57:04 Integrated Voltage Measurement... 21:57:13 Voltage Offset Correction: v_off_ini = 2662.410 uV, v_off_fin = 2650.981 uV 21:57:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.014 uVs 21:57:13 Integrated Voltage Measurement... 21:57:22 Voltage Offset Correction: v_off_ini = 2664.127 uV, v_off_fin = 2675.102 uV 21:57:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 165.480 uVs 21:57:26 I1Y Average and RMS of Measurements VT = -182.673 +- 10.633 uVs I1Y = -36.532 +- 2.127 uTm 21:57:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:57:31 Integrated Voltage Measurement... 21:57:40 Voltage Offset Correction: v_off_ini = 2654.638 uV, v_off_fin = 2670.737 uV 21:57:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.131 uVs 21:57:40 Integrated Voltage Measurement... 21:57:49 Voltage Offset Correction: v_off_ini = 2678.352 uV, v_off_fin = 2701.394 uV 21:57:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.561 uVs 21:57:49 Integrated Voltage Measurement... 21:57:58 Voltage Offset Correction: v_off_ini = 2694.066 uV, v_off_fin = 2689.153 uV 21:57:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.757 uVs 21:57:58 Integrated Voltage Measurement... 21:58:07 Voltage Offset Correction: v_off_ini = 2693.334 uV, v_off_fin = 2696.138 uV 21:58:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.509 uVs 21:58:07 Integrated Voltage Measurement... 21:58:16 Voltage Offset Correction: v_off_ini = 2689.593 uV, v_off_fin = 2682.307 uV 21:58:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.619 uVs 21:58:16 Integrated Voltage Measurement... 21:58:25 Voltage Offset Correction: v_off_ini = 2667.138 uV, v_off_fin = 2685.414 uV 21:58:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 131.865 uVs 21:58:28 I2X Average and RMS of Measurements VT = -132.407 +- 3.378 uVs I2X = 12.182 +- 0.311 uTm^2 21:58:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:58:33 Integrated Voltage Measurement... 21:58:42 Voltage Offset Correction: v_off_ini = 2681.491 uV, v_off_fin = 2632.993 uV 21:58:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -126.603 uVs 21:58:42 Integrated Voltage Measurement... 21:58:51 Voltage Offset Correction: v_off_ini = 2666.641 uV, v_off_fin = 2684.736 uV 21:58:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 147.285 uVs 21:58:51 Integrated Voltage Measurement... 21:59:00 Voltage Offset Correction: v_off_ini = 2681.314 uV, v_off_fin = 2676.581 uV 21:59:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -155.521 uVs 21:59:00 Integrated Voltage Measurement... 21:59:09 Voltage Offset Correction: v_off_ini = 2700.525 uV, v_off_fin = 2707.973 uV 21:59:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 151.597 uVs 21:59:09 Integrated Voltage Measurement... 21:59:18 Voltage Offset Correction: v_off_ini = 2720.110 uV, v_off_fin = 2712.005 uV 21:59:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -156.105 uVs 21:59:18 Integrated Voltage Measurement... 21:59:27 Voltage Offset Correction: v_off_ini = 2692.478 uV, v_off_fin = 2675.425 uV 21:59:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 149.885 uVs 21:59:29 I2Y Average and RMS of Measurements VT = -147.833 +- 7.703 uVs I2Y = -13.601 +- 0.709 uTm^2 22:00:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 22:00:04 Integrated Voltage Measurement... 22:00:13 Voltage Offset Correction: v_off_ini = 2713.710 uV, v_off_fin = 2695.186 uV 22:00:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.338 uVs 22:00:13 Integrated Voltage Measurement... 22:00:22 Voltage Offset Correction: v_off_ini = 2684.409 uV, v_off_fin = 2685.491 uV 22:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.623 uVs 22:00:22 Integrated Voltage Measurement... 22:00:31 Voltage Offset Correction: v_off_ini = 2735.914 uV, v_off_fin = 2705.356 uV 22:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.005 uVs 22:00:31 Integrated Voltage Measurement... 22:00:40 Voltage Offset Correction: v_off_ini = 2722.713 uV, v_off_fin = 2718.229 uV 22:00:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.960 uVs 22:00:40 Integrated Voltage Measurement... 22:00:49 Voltage Offset Correction: v_off_ini = 2695.960 uV, v_off_fin = 2688.477 uV 22:00:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.024 uVs 22:00:49 Integrated Voltage Measurement... 22:00:58 Voltage Offset Correction: v_off_ini = 2700.659 uV, v_off_fin = 2684.354 uV 22:00:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.928 uVs 22:01:02 I1X Average and RMS of Measurements VT = -82.980 +- 1.225 uVs I1X = 16.596 +- 0.245 uTm 22:01:05 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 22:01:09 Integrated Voltage Measurement... 22:01:18 Voltage Offset Correction: v_off_ini = 2688.993 uV, v_off_fin = 2688.264 uV 22:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.459 uVs 22:01:18 Integrated Voltage Measurement... 22:01:27 Voltage Offset Correction: v_off_ini = 2696.012 uV, v_off_fin = 2714.342 uV 22:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.094 uVs 22:01:27 Integrated Voltage Measurement... 22:01:36 Voltage Offset Correction: v_off_ini = 2693.356 uV, v_off_fin = 2687.159 uV 22:01:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.819 uVs 22:01:36 Integrated Voltage Measurement... 22:01:45 Voltage Offset Correction: v_off_ini = 2691.318 uV, v_off_fin = 2701.689 uV 22:01:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.364 uVs 22:01:45 Integrated Voltage Measurement... 22:01:54 Voltage Offset Correction: v_off_ini = 2672.734 uV, v_off_fin = 2658.967 uV 22:01:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.905 uVs 22:01:54 Integrated Voltage Measurement... 22:02:03 Voltage Offset Correction: v_off_ini = 2652.010 uV, v_off_fin = 2689.783 uV 22:02:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.689 uVs 22:02:07 I1Y Average and RMS of Measurements VT = -208.055 +- 2.541 uVs I1Y = -41.611 +- 0.508 uTm 22:02:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 22:02:15 Integrated Voltage Measurement... 22:02:24 Voltage Offset Correction: v_off_ini = 2675.585 uV, v_off_fin = 2678.909 uV 22:02:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.677 uVs 22:02:24 Integrated Voltage Measurement... 22:02:33 Voltage Offset Correction: v_off_ini = 2686.909 uV, v_off_fin = 2700.919 uV 22:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.622 uVs 22:02:33 Integrated Voltage Measurement... 22:02:42 Voltage Offset Correction: v_off_ini = 2702.528 uV, v_off_fin = 2692.098 uV 22:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.173 uVs 22:02:42 Integrated Voltage Measurement... 22:02:51 Voltage Offset Correction: v_off_ini = 2702.036 uV, v_off_fin = 2682.974 uV 22:02:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.053 uVs 22:02:51 Integrated Voltage Measurement... 22:03:00 Voltage Offset Correction: v_off_ini = 2679.673 uV, v_off_fin = 2681.522 uV 22:03:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.784 uVs 22:03:00 Integrated Voltage Measurement... 22:03:09 Voltage Offset Correction: v_off_ini = 2703.719 uV, v_off_fin = 2724.080 uV 22:03:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.135 uVs 22:03:11 I2X Average and RMS of Measurements VT = -63.241 +- 11.650 uVs I2X = 5.818 +- 1.072 uTm^2 22:03:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 22:03:19 Integrated Voltage Measurement... 22:03:28 Voltage Offset Correction: v_off_ini = 2724.177 uV, v_off_fin = 2731.840 uV 22:03:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.309 uVs 22:03:28 Integrated Voltage Measurement... 22:03:37 Voltage Offset Correction: v_off_ini = 2722.774 uV, v_off_fin = 2719.182 uV 22:03:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 207.961 uVs 22:03:37 Integrated Voltage Measurement... 22:03:46 Voltage Offset Correction: v_off_ini = 2719.724 uV, v_off_fin = 2729.573 uV 22:03:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.189 uVs 22:03:46 Integrated Voltage Measurement... 22:03:55 Voltage Offset Correction: v_off_ini = 2742.064 uV, v_off_fin = 2739.991 uV 22:03:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.616 uVs 22:03:55 Integrated Voltage Measurement... 22:04:04 Voltage Offset Correction: v_off_ini = 2732.652 uV, v_off_fin = 2723.761 uV 22:04:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.387 uVs 22:04:04 Integrated Voltage Measurement... 22:04:13 Voltage Offset Correction: v_off_ini = 2728.756 uV, v_off_fin = 2722.331 uV 22:04:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.281 uVs 22:04:15 I2Y Average and RMS of Measurements VT = -210.457 +- 4.066 uVs I2Y = -19.362 +- 0.374 uTm^2 22:04:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 22:04:24 Integrated Voltage Measurement... 22:04:33 Voltage Offset Correction: v_off_ini = 2724.466 uV, v_off_fin = 2747.567 uV 22:04:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -73.445 uVs 22:04:33 Integrated Voltage Measurement... 22:04:42 Voltage Offset Correction: v_off_ini = 2737.619 uV, v_off_fin = 2755.587 uV 22:04:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.084 uVs 22:04:42 Integrated Voltage Measurement... 22:04:51 Voltage Offset Correction: v_off_ini = 2740.848 uV, v_off_fin = 2729.706 uV 22:04:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.383 uVs 22:04:51 Integrated Voltage Measurement... 22:05:00 Voltage Offset Correction: v_off_ini = 2724.446 uV, v_off_fin = 2712.131 uV 22:05:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.705 uVs 22:05:00 Integrated Voltage Measurement... 22:05:09 Voltage Offset Correction: v_off_ini = 2728.886 uV, v_off_fin = 2730.857 uV 22:05:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.113 uVs 22:05:09 Integrated Voltage Measurement... 22:05:18 Voltage Offset Correction: v_off_ini = 2743.150 uV, v_off_fin = 2738.503 uV 22:05:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.961 uVs 22:05:22 I1X Average and RMS of Measurements VT = -77.948 +- 2.854 uVs I1X = 15.591 +- 0.571 uTm 22:05:25 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 22:05:29 Integrated Voltage Measurement... 22:05:38 Voltage Offset Correction: v_off_ini = 2718.931 uV, v_off_fin = 2721.770 uV 22:05:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.943 uVs 22:05:38 Integrated Voltage Measurement... 22:05:47 Voltage Offset Correction: v_off_ini = 2724.586 uV, v_off_fin = 2740.091 uV 22:05:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.279 uVs 22:05:47 Integrated Voltage Measurement... 22:05:56 Voltage Offset Correction: v_off_ini = 2712.709 uV, v_off_fin = 2701.830 uV 22:05:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.318 uVs 22:05:56 Integrated Voltage Measurement... 22:06:05 Voltage Offset Correction: v_off_ini = 2704.363 uV, v_off_fin = 2701.360 uV 22:06:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.298 uVs 22:06:05 Integrated Voltage Measurement... 22:06:14 Voltage Offset Correction: v_off_ini = 2711.407 uV, v_off_fin = 2691.115 uV 22:06:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.419 uVs 22:06:14 Integrated Voltage Measurement... 22:06:23 Voltage Offset Correction: v_off_ini = 2712.646 uV, v_off_fin = 2728.151 uV 22:06:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.535 uVs 22:06:27 I1Y Average and RMS of Measurements VT = -209.465 +- 6.683 uVs I1Y = -41.894 +- 1.337 uTm 22:06:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 22:06:35 Integrated Voltage Measurement... 22:06:44 Voltage Offset Correction: v_off_ini = 2730.413 uV, v_off_fin = 2744.630 uV 22:06:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.666 uVs 22:06:44 Integrated Voltage Measurement... 22:06:53 Voltage Offset Correction: v_off_ini = 2728.385 uV, v_off_fin = 2720.508 uV 22:06:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.171 uVs 22:06:53 Integrated Voltage Measurement... 22:07:02 Voltage Offset Correction: v_off_ini = 2707.393 uV, v_off_fin = 2700.266 uV 22:07:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.329 uVs 22:07:02 Integrated Voltage Measurement... 22:07:11 Voltage Offset Correction: v_off_ini = 2700.081 uV, v_off_fin = 2707.735 uV 22:07:11 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 85.658 uVs 22:07:11 Integrated Voltage Measurement... 22:07:20 Voltage Offset Correction: v_off_ini = 2713.803 uV, v_off_fin = 2702.959 uV 22:07:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -87.020 uVs 22:07:20 Integrated Voltage Measurement... 22:07:29 Voltage Offset Correction: v_off_ini = 2699.004 uV, v_off_fin = 2705.657 uV 22:07:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 41.898 uVs 22:07:32 I2X Average and RMS of Measurements VT = -69.957 +- 7.804 uVs I2X = 6.437 +- 0.718 uTm^2 22:07:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 22:07:39 Integrated Voltage Measurement... 22:07:48 Voltage Offset Correction: v_off_ini = 2700.288 uV, v_off_fin = 2689.014 uV 22:07:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.837 uVs 22:07:48 Integrated Voltage Measurement... 22:07:57 Voltage Offset Correction: v_off_ini = 2713.133 uV, v_off_fin = 2708.152 uV 22:07:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.931 uVs 22:07:57 Integrated Voltage Measurement... 22:08:06 Voltage Offset Correction: v_off_ini = 2684.535 uV, v_off_fin = 2683.818 uV 22:08:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.985 uVs 22:08:06 Integrated Voltage Measurement... 22:08:15 Voltage Offset Correction: v_off_ini = 2687.080 uV, v_off_fin = 2701.400 uV 22:08:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.605 uVs 22:08:15 Integrated Voltage Measurement... 22:08:24 Voltage Offset Correction: v_off_ini = 2681.342 uV, v_off_fin = 2687.964 uV 22:08:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.987 uVs 22:08:24 Integrated Voltage Measurement... 22:08:33 Voltage Offset Correction: v_off_ini = 2674.372 uV, v_off_fin = 2674.999 uV 22:08:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.054 uVs 22:08:36 I2Y Average and RMS of Measurements VT = -205.566 +- 12.573 uVs I2Y = -18.912 +- 1.157 uTm^2 22:08:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:08:45 Integrated Voltage Measurement... 22:08:54 Voltage Offset Correction: v_off_ini = 2693.783 uV, v_off_fin = 2690.454 uV 22:08:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.323 uVs 22:08:54 Integrated Voltage Measurement... 22:09:03 Voltage Offset Correction: v_off_ini = 2700.576 uV, v_off_fin = 2699.466 uV 22:09:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.223 uVs 22:09:03 Integrated Voltage Measurement... 22:09:12 Voltage Offset Correction: v_off_ini = 2681.472 uV, v_off_fin = 2694.575 uV 22:09:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.893 uVs 22:09:12 Integrated Voltage Measurement... 22:09:21 Voltage Offset Correction: v_off_ini = 2677.640 uV, v_off_fin = 2707.651 uV 22:09:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.411 uVs 22:09:21 Integrated Voltage Measurement... 22:09:30 Voltage Offset Correction: v_off_ini = 2690.819 uV, v_off_fin = 2691.999 uV 22:09:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.501 uVs 22:09:30 Integrated Voltage Measurement... 22:09:39 Voltage Offset Correction: v_off_ini = 2705.654 uV, v_off_fin = 2697.449 uV 22:09:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.983 uVs 22:09:43 I1X Average and RMS of Measurements VT = -87.389 +- 7.058 uVs I1X = 17.478 +- 1.411 uTm 22:09:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:09:50 Integrated Voltage Measurement... 22:09:59 Voltage Offset Correction: v_off_ini = 2702.797 uV, v_off_fin = 2695.175 uV 22:09:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.275 uVs 22:09:59 Integrated Voltage Measurement... 22:10:08 Voltage Offset Correction: v_off_ini = 2694.302 uV, v_off_fin = 2713.731 uV 22:10:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.401 uVs 22:10:08 Integrated Voltage Measurement... 22:10:16 Voltage Offset Correction: v_off_ini = 2719.767 uV, v_off_fin = 2699.575 uV 22:10:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.450 uVs 22:10:17 Integrated Voltage Measurement... 22:10:25 Voltage Offset Correction: v_off_ini = 2715.246 uV, v_off_fin = 2699.774 uV 22:10:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.146 uVs 22:10:26 Integrated Voltage Measurement... 22:10:34 Voltage Offset Correction: v_off_ini = 2724.119 uV, v_off_fin = 2723.050 uV 22:10:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.765 uVs 22:10:35 Integrated Voltage Measurement... 22:10:43 Voltage Offset Correction: v_off_ini = 2717.956 uV, v_off_fin = 2713.538 uV 22:10:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.877 uVs 22:10:48 I1Y Average and RMS of Measurements VT = -198.486 +- 8.257 uVs I1Y = -39.697 +- 1.651 uTm 22:10:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:10:55 Integrated Voltage Measurement... 22:11:04 Voltage Offset Correction: v_off_ini = 2746.171 uV, v_off_fin = 2733.226 uV 22:11:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.624 uVs 22:11:04 Integrated Voltage Measurement... 22:11:13 Voltage Offset Correction: v_off_ini = 2730.803 uV, v_off_fin = 2736.439 uV 22:11:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.677 uVs 22:11:13 Integrated Voltage Measurement... 22:11:22 Voltage Offset Correction: v_off_ini = 2727.489 uV, v_off_fin = 2716.621 uV 22:11:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.424 uVs 22:11:22 Integrated Voltage Measurement... 22:11:31 Voltage Offset Correction: v_off_ini = 2717.025 uV, v_off_fin = 2744.031 uV 22:11:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.454 uVs 22:11:32 Integrated Voltage Measurement... 22:11:40 Voltage Offset Correction: v_off_ini = 2709.015 uV, v_off_fin = 2703.397 uV 22:11:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.068 uVs 22:11:41 Integrated Voltage Measurement... 22:11:50 Voltage Offset Correction: v_off_ini = 2711.836 uV, v_off_fin = 2718.424 uV 22:11:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.155 uVs 22:11:52 I2X Average and RMS of Measurements VT = -75.901 +- 24.420 uVs I2X = 6.983 +- 2.247 uTm^2 22:11:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:12:00 Integrated Voltage Measurement... 22:12:09 Voltage Offset Correction: v_off_ini = 2708.862 uV, v_off_fin = 2698.472 uV 22:12:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.253 uVs 22:12:09 Integrated Voltage Measurement... 22:12:18 Voltage Offset Correction: v_off_ini = 2699.822 uV, v_off_fin = 2704.296 uV 22:12:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.490 uVs 22:12:18 Integrated Voltage Measurement... 22:12:27 Voltage Offset Correction: v_off_ini = 2736.518 uV, v_off_fin = 2727.417 uV 22:12:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.813 uVs 22:12:27 Integrated Voltage Measurement... 22:12:36 Voltage Offset Correction: v_off_ini = 2722.426 uV, v_off_fin = 2707.663 uV 22:12:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.698 uVs 22:12:36 Integrated Voltage Measurement... 22:12:45 Voltage Offset Correction: v_off_ini = 2702.247 uV, v_off_fin = 2707.663 uV 22:12:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.885 uVs 22:12:45 Integrated Voltage Measurement... 22:12:54 Voltage Offset Correction: v_off_ini = 2699.231 uV, v_off_fin = 2723.256 uV 22:12:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.640 uVs 22:12:56 I2Y Average and RMS of Measurements VT = -211.630 +- 2.224 uVs I2Y = -19.470 +- 0.205 uTm^2 22:13:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 22:13:05 Integrated Voltage Measurement... 22:13:14 Voltage Offset Correction: v_off_ini = 2703.472 uV, v_off_fin = 2692.909 uV 22:13:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -71.381 uVs 22:13:14 Integrated Voltage Measurement... 22:13:23 Voltage Offset Correction: v_off_ini = 2685.033 uV, v_off_fin = 2694.642 uV 22:13:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.446 uVs 22:13:23 Integrated Voltage Measurement... 22:13:32 Voltage Offset Correction: v_off_ini = 2679.195 uV, v_off_fin = 2680.869 uV 22:13:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.115 uVs 22:13:32 Integrated Voltage Measurement... 22:13:41 Voltage Offset Correction: v_off_ini = 2684.636 uV, v_off_fin = 2693.434 uV 22:13:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.536 uVs 22:13:41 Integrated Voltage Measurement... 22:13:50 Voltage Offset Correction: v_off_ini = 2716.461 uV, v_off_fin = 2690.377 uV 22:13:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.447 uVs 22:13:50 Integrated Voltage Measurement... 22:13:59 Voltage Offset Correction: v_off_ini = 2662.658 uV, v_off_fin = 2684.943 uV 22:13:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.850 uVs 22:14:03 I1X Average and RMS of Measurements VT = -62.796 +- 7.586 uVs I1X = 12.560 +- 1.518 uTm 22:14:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 22:14:10 Integrated Voltage Measurement... 22:14:19 Voltage Offset Correction: v_off_ini = 2692.238 uV, v_off_fin = 2660.732 uV 22:14:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.796 uVs 22:14:19 Integrated Voltage Measurement... 22:14:28 Voltage Offset Correction: v_off_ini = 2675.451 uV, v_off_fin = 2680.408 uV 22:14:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.271 uVs 22:14:28 Integrated Voltage Measurement... 22:14:37 Voltage Offset Correction: v_off_ini = 2701.978 uV, v_off_fin = 2674.936 uV 22:14:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.930 uVs 22:14:37 Integrated Voltage Measurement... 22:14:46 Voltage Offset Correction: v_off_ini = 2702.379 uV, v_off_fin = 2718.261 uV 22:14:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.406 uVs 22:14:46 Integrated Voltage Measurement... 22:14:55 Voltage Offset Correction: v_off_ini = 2709.070 uV, v_off_fin = 2697.912 uV 22:14:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.169 uVs 22:14:55 Integrated Voltage Measurement... 22:15:04 Voltage Offset Correction: v_off_ini = 2693.225 uV, v_off_fin = 2704.556 uV 22:15:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.556 uVs 22:15:08 I1Y Average and RMS of Measurements VT = -212.022 +- 6.098 uVs I1Y = -42.404 +- 1.220 uTm 22:15:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 22:15:16 Integrated Voltage Measurement... 22:15:25 Voltage Offset Correction: v_off_ini = 2713.079 uV, v_off_fin = 2695.945 uV 22:15:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.043 uVs 22:15:25 Integrated Voltage Measurement... 22:15:34 Voltage Offset Correction: v_off_ini = 2716.399 uV, v_off_fin = 2729.953 uV 22:15:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.245 uVs 22:15:34 Integrated Voltage Measurement... 22:15:43 Voltage Offset Correction: v_off_ini = 2700.900 uV, v_off_fin = 2694.775 uV 22:15:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.781 uVs 22:15:43 Integrated Voltage Measurement... 22:15:52 Voltage Offset Correction: v_off_ini = 2720.129 uV, v_off_fin = 2728.889 uV 22:15:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.177 uVs 22:15:52 Integrated Voltage Measurement... 22:16:01 Voltage Offset Correction: v_off_ini = 2699.845 uV, v_off_fin = 2681.721 uV 22:16:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.093 uVs 22:16:01 Integrated Voltage Measurement... 22:16:10 Voltage Offset Correction: v_off_ini = 2694.698 uV, v_off_fin = 2706.189 uV 22:16:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.234 uVs 22:16:12 I2X Average and RMS of Measurements VT = -61.262 +- 8.245 uVs I2X = 5.636 +- 0.759 uTm^2 22:16:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 22:16:20 Integrated Voltage Measurement... 22:16:29 Voltage Offset Correction: v_off_ini = 2679.658 uV, v_off_fin = 2675.251 uV 22:16:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.149 uVs 22:16:29 Integrated Voltage Measurement... 22:16:38 Voltage Offset Correction: v_off_ini = 2682.092 uV, v_off_fin = 2693.788 uV 22:16:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.503 uVs 22:16:38 Integrated Voltage Measurement... 22:16:47 Voltage Offset Correction: v_off_ini = 2700.176 uV, v_off_fin = 2692.477 uV 22:16:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -184.799 uVs 22:16:47 Integrated Voltage Measurement... 22:16:56 Voltage Offset Correction: v_off_ini = 2679.824 uV, v_off_fin = 2679.996 uV 22:16:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.143 uVs 22:16:56 Integrated Voltage Measurement... 22:17:05 Voltage Offset Correction: v_off_ini = 2685.136 uV, v_off_fin = 2686.551 uV 22:17:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.982 uVs 22:17:05 Integrated Voltage Measurement... 22:17:14 Voltage Offset Correction: v_off_ini = 2696.303 uV, v_off_fin = 2692.261 uV 22:17:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.002 uVs 22:17:17 I2Y Average and RMS of Measurements VT = -192.763 +- 5.578 uVs I2Y = -17.734 +- 0.513 uTm^2 22:17:21 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 22:17:25 Integrated Voltage Measurement... 22:17:34 Voltage Offset Correction: v_off_ini = 2689.697 uV, v_off_fin = 2687.946 uV 22:17:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -60.426 uVs 22:17:34 Integrated Voltage Measurement... 22:17:43 Voltage Offset Correction: v_off_ini = 2689.807 uV, v_off_fin = 2701.600 uV 22:17:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.211 uVs 22:17:43 Integrated Voltage Measurement... 22:17:52 Voltage Offset Correction: v_off_ini = 2687.481 uV, v_off_fin = 2683.065 uV 22:17:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.522 uVs 22:17:52 Integrated Voltage Measurement... 22:18:01 Voltage Offset Correction: v_off_ini = 2724.477 uV, v_off_fin = 2732.255 uV 22:18:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.829 uVs 22:18:01 Integrated Voltage Measurement... 22:18:10 Voltage Offset Correction: v_off_ini = 2707.315 uV, v_off_fin = 2680.932 uV 22:18:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.039 uVs 22:18:10 Integrated Voltage Measurement... 22:18:19 Voltage Offset Correction: v_off_ini = 2701.230 uV, v_off_fin = 2669.582 uV 22:18:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.600 uVs 22:18:24 I1X Average and RMS of Measurements VT = -67.604 +- 9.127 uVs I1X = 13.521 +- 1.825 uTm 22:18:26 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 22:18:30 Integrated Voltage Measurement... 22:18:39 Voltage Offset Correction: v_off_ini = 2714.527 uV, v_off_fin = 2697.310 uV 22:18:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.162 uVs 22:18:39 Integrated Voltage Measurement... 22:18:48 Voltage Offset Correction: v_off_ini = 2696.654 uV, v_off_fin = 2705.285 uV 22:18:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.685 uVs 22:18:48 Integrated Voltage Measurement... 22:18:57 Voltage Offset Correction: v_off_ini = 2712.920 uV, v_off_fin = 2697.459 uV 22:18:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.238 uVs 22:18:57 Integrated Voltage Measurement... 22:19:06 Voltage Offset Correction: v_off_ini = 2670.581 uV, v_off_fin = 2674.095 uV 22:19:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.206 uVs 22:19:06 Integrated Voltage Measurement... 22:19:15 Voltage Offset Correction: v_off_ini = 2711.439 uV, v_off_fin = 2696.781 uV 22:19:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.541 uVs 22:19:15 Integrated Voltage Measurement... 22:19:24 Voltage Offset Correction: v_off_ini = 2698.815 uV, v_off_fin = 2693.532 uV 22:19:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.632 uVs 22:19:28 I1Y Average and RMS of Measurements VT = -202.911 +- 5.940 uVs I1Y = -40.582 +- 1.188 uTm 22:19:33 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 22:19:36 Integrated Voltage Measurement... 22:19:45 Voltage Offset Correction: v_off_ini = 2676.391 uV, v_off_fin = 2665.687 uV 22:19:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.225 uVs 22:19:45 Integrated Voltage Measurement... 22:19:54 Voltage Offset Correction: v_off_ini = 2687.574 uV, v_off_fin = 2686.557 uV 22:19:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.873 uVs 22:19:54 Integrated Voltage Measurement... 22:20:03 Voltage Offset Correction: v_off_ini = 2689.905 uV, v_off_fin = 2679.413 uV 22:20:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.036 uVs 22:20:03 Integrated Voltage Measurement... 22:20:12 Voltage Offset Correction: v_off_ini = 2709.937 uV, v_off_fin = 2690.181 uV 22:20:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 16.921 uVs 22:20:12 Integrated Voltage Measurement... 22:20:21 Voltage Offset Correction: v_off_ini = 2671.721 uV, v_off_fin = 2683.336 uV 22:20:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.952 uVs 22:20:21 Integrated Voltage Measurement... 22:20:30 Voltage Offset Correction: v_off_ini = 2699.517 uV, v_off_fin = 2668.633 uV 22:20:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.204 uVs 22:20:33 I2X Average and RMS of Measurements VT = -54.702 +- 14.522 uVs I2X = 5.033 +- 1.336 uTm^2 22:20:38 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 22:20:40 Integrated Voltage Measurement... 22:20:49 Voltage Offset Correction: v_off_ini = 2664.842 uV, v_off_fin = 2669.136 uV 22:20:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.290 uVs 22:20:49 Integrated Voltage Measurement... 22:20:58 Voltage Offset Correction: v_off_ini = 2672.477 uV, v_off_fin = 2672.143 uV 22:20:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.185 uVs 22:20:58 Integrated Voltage Measurement... 22:21:07 Voltage Offset Correction: v_off_ini = 2664.698 uV, v_off_fin = 2656.427 uV 22:21:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.216 uVs 22:21:07 Integrated Voltage Measurement... 22:21:16 Voltage Offset Correction: v_off_ini = 2632.392 uV, v_off_fin = 2644.582 uV 22:21:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.098 uVs 22:21:16 Integrated Voltage Measurement... 22:21:25 Voltage Offset Correction: v_off_ini = 2643.860 uV, v_off_fin = 2640.345 uV 22:21:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.589 uVs 22:21:25 Integrated Voltage Measurement... 22:21:34 Voltage Offset Correction: v_off_ini = 2645.878 uV, v_off_fin = 2661.891 uV 22:21:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.982 uVs 22:21:37 I2Y Average and RMS of Measurements VT = -215.893 +- 5.213 uVs I2Y = -19.862 +- 0.480 uTm^2 22:21:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 22:21:49 Integrated Voltage Measurement... 22:21:58 Voltage Offset Correction: v_off_ini = 2657.937 uV, v_off_fin = 2644.600 uV 22:21:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.083 uVs 22:21:58 Integrated Voltage Measurement... 22:22:07 Voltage Offset Correction: v_off_ini = 2658.754 uV, v_off_fin = 2648.926 uV 22:22:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.420 uVs 22:22:07 Integrated Voltage Measurement... 22:22:16 Voltage Offset Correction: v_off_ini = 2633.533 uV, v_off_fin = 2630.753 uV 22:22:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.074 uVs 22:22:16 Integrated Voltage Measurement... 22:22:25 Voltage Offset Correction: v_off_ini = 2631.205 uV, v_off_fin = 2627.895 uV 22:22:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 79.335 uVs 22:22:25 Integrated Voltage Measurement... 22:22:34 Voltage Offset Correction: v_off_ini = 2653.961 uV, v_off_fin = 2627.724 uV 22:22:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.983 uVs 22:22:34 Integrated Voltage Measurement... 22:22:43 Voltage Offset Correction: v_off_ini = 2662.932 uV, v_off_fin = 2665.249 uV 22:22:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.980 uVs 22:22:47 I1X Average and RMS of Measurements VT = -69.146 +- 5.359 uVs I1X = 13.830 +- 1.071 uTm 22:22:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 22:22:54 Integrated Voltage Measurement... 22:23:03 Voltage Offset Correction: v_off_ini = 2660.437 uV, v_off_fin = 2654.319 uV 22:23:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.105 uVs 22:23:03 Integrated Voltage Measurement... 22:23:12 Voltage Offset Correction: v_off_ini = 2672.969 uV, v_off_fin = 2688.276 uV 22:23:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.784 uVs 22:23:12 Integrated Voltage Measurement... 22:23:21 Voltage Offset Correction: v_off_ini = 2669.655 uV, v_off_fin = 2663.283 uV 22:23:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.627 uVs 22:23:21 Integrated Voltage Measurement... 22:23:30 Voltage Offset Correction: v_off_ini = 2687.353 uV, v_off_fin = 2679.274 uV 22:23:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.496 uVs 22:23:30 Integrated Voltage Measurement... 22:23:39 Voltage Offset Correction: v_off_ini = 2666.521 uV, v_off_fin = 2637.602 uV 22:23:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.187 uVs 22:23:39 Integrated Voltage Measurement... 22:23:48 Voltage Offset Correction: v_off_ini = 2647.824 uV, v_off_fin = 2664.958 uV 22:23:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.177 uVs 22:23:52 I1Y Average and RMS of Measurements VT = -214.563 +- 2.478 uVs I1Y = -42.913 +- 0.496 uTm 22:23:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 22:23:57 Integrated Voltage Measurement... 22:24:06 Voltage Offset Correction: v_off_ini = 2649.214 uV, v_off_fin = 2662.356 uV 22:24:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -60.028 uVs 22:24:06 Integrated Voltage Measurement... 22:24:15 Voltage Offset Correction: v_off_ini = 2636.455 uV, v_off_fin = 2644.698 uV 22:24:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.090 uVs 22:24:15 Integrated Voltage Measurement... 22:24:24 Voltage Offset Correction: v_off_ini = 2674.736 uV, v_off_fin = 2654.262 uV 22:24:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.016 uVs 22:24:24 Integrated Voltage Measurement... 22:24:33 Voltage Offset Correction: v_off_ini = 2656.293 uV, v_off_fin = 2654.405 uV 22:24:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.533 uVs 22:24:33 Integrated Voltage Measurement... 22:24:42 Voltage Offset Correction: v_off_ini = 2648.302 uV, v_off_fin = 2653.437 uV 22:24:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.275 uVs 22:24:42 Integrated Voltage Measurement... 22:24:51 Voltage Offset Correction: v_off_ini = 2641.984 uV, v_off_fin = 2642.481 uV 22:24:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.655 uVs 22:24:54 I2X Average and RMS of Measurements VT = -68.266 +- 8.325 uVs I2X = 6.280 +- 0.766 uTm^2 22:24:56 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 22:24:59 Integrated Voltage Measurement... 22:25:08 Voltage Offset Correction: v_off_ini = 2647.050 uV, v_off_fin = 2628.761 uV 22:25:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.623 uVs 22:25:08 Integrated Voltage Measurement... 22:25:17 Voltage Offset Correction: v_off_ini = 2655.927 uV, v_off_fin = 2665.537 uV 22:25:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.214 uVs 22:25:17 Integrated Voltage Measurement... 22:25:26 Voltage Offset Correction: v_off_ini = 2649.654 uV, v_off_fin = 2645.615 uV 22:25:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.199 uVs 22:25:26 Integrated Voltage Measurement... 22:25:35 Voltage Offset Correction: v_off_ini = 2629.367 uV, v_off_fin = 2647.134 uV 22:25:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.886 uVs 22:25:35 Integrated Voltage Measurement... 22:25:44 Voltage Offset Correction: v_off_ini = 2634.277 uV, v_off_fin = 2657.036 uV 22:25:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.579 uVs 22:25:44 Integrated Voltage Measurement... 22:25:53 Voltage Offset Correction: v_off_ini = 2633.005 uV, v_off_fin = 2670.448 uV 22:25:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.816 uVs 22:25:55 I2Y Average and RMS of Measurements VT = -209.720 +- 3.005 uVs I2Y = -19.294 +- 0.276 uTm^2 22:25:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 22:26:03 Integrated Voltage Measurement... 22:26:12 Voltage Offset Correction: v_off_ini = 2692.363 uV, v_off_fin = 2666.694 uV 22:26:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -54.207 uVs 22:26:13 Integrated Voltage Measurement... 22:26:21 Voltage Offset Correction: v_off_ini = 2688.864 uV, v_off_fin = 2681.021 uV 22:26:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.430 uVs 22:26:22 Integrated Voltage Measurement... 22:26:30 Voltage Offset Correction: v_off_ini = 2679.263 uV, v_off_fin = 2676.198 uV 22:26:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.385 uVs 22:26:31 Integrated Voltage Measurement... 22:26:39 Voltage Offset Correction: v_off_ini = 2676.797 uV, v_off_fin = 2672.336 uV 22:26:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.862 uVs 22:26:40 Integrated Voltage Measurement... 22:26:48 Voltage Offset Correction: v_off_ini = 2673.683 uV, v_off_fin = 2668.163 uV 22:26:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -43.175 uVs 22:26:49 Integrated Voltage Measurement... 22:26:57 Voltage Offset Correction: v_off_ini = 2663.559 uV, v_off_fin = 2654.276 uV 22:26:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.109 uVs 22:27:02 I1X Average and RMS of Measurements VT = -71.028 +- 13.466 uVs I1X = 14.207 +- 2.693 uTm 22:27:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 22:27:08 Integrated Voltage Measurement... 22:27:17 Voltage Offset Correction: v_off_ini = 2624.117 uV, v_off_fin = 2634.825 uV 22:27:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.942 uVs 22:27:17 Integrated Voltage Measurement... 22:27:26 Voltage Offset Correction: v_off_ini = 2651.792 uV, v_off_fin = 2662.075 uV 22:27:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.101 uVs 22:27:26 Integrated Voltage Measurement... 22:27:35 Voltage Offset Correction: v_off_ini = 2644.440 uV, v_off_fin = 2644.448 uV 22:27:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.640 uVs 22:27:35 Integrated Voltage Measurement... 22:27:44 Voltage Offset Correction: v_off_ini = 2657.026 uV, v_off_fin = 2654.045 uV 22:27:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.445 uVs 22:27:44 Integrated Voltage Measurement... 22:27:53 Voltage Offset Correction: v_off_ini = 2642.126 uV, v_off_fin = 2610.321 uV 22:27:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.624 uVs 22:27:53 Integrated Voltage Measurement... 22:28:02 Voltage Offset Correction: v_off_ini = 2628.752 uV, v_off_fin = 2636.029 uV 22:28:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.912 uVs 22:28:07 I1Y Average and RMS of Measurements VT = -211.110 +- 4.335 uVs I1Y = -42.222 +- 0.867 uTm 22:28:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 22:28:12 Integrated Voltage Measurement... 22:28:21 Voltage Offset Correction: v_off_ini = 2621.600 uV, v_off_fin = 2604.027 uV 22:28:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.553 uVs 22:28:21 Integrated Voltage Measurement... 22:28:30 Voltage Offset Correction: v_off_ini = 2624.487 uV, v_off_fin = 2641.866 uV 22:28:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.785 uVs 22:28:30 Integrated Voltage Measurement... 22:28:39 Voltage Offset Correction: v_off_ini = 2621.631 uV, v_off_fin = 2603.769 uV 22:28:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.749 uVs 22:28:39 Integrated Voltage Measurement... 22:28:48 Voltage Offset Correction: v_off_ini = 2600.744 uV, v_off_fin = 2617.654 uV 22:28:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.705 uVs 22:28:48 Integrated Voltage Measurement... 22:28:57 Voltage Offset Correction: v_off_ini = 2608.048 uV, v_off_fin = 2608.228 uV 22:28:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.059 uVs 22:28:57 Integrated Voltage Measurement... 22:29:06 Voltage Offset Correction: v_off_ini = 2596.770 uV, v_off_fin = 2590.545 uV 22:29:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.937 uVs 22:29:08 I2X Average and RMS of Measurements VT = -64.965 +- 7.136 uVs I2X = 5.977 +- 0.657 uTm^2 22:29:11 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 22:29:13 Integrated Voltage Measurement... 22:29:22 Voltage Offset Correction: v_off_ini = 2594.526 uV, v_off_fin = 2578.426 uV 22:29:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.051 uVs 22:29:22 Integrated Voltage Measurement... 22:29:31 Voltage Offset Correction: v_off_ini = 2581.521 uV, v_off_fin = 2592.195 uV 22:29:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.926 uVs 22:29:31 Integrated Voltage Measurement... 22:29:40 Voltage Offset Correction: v_off_ini = 2586.859 uV, v_off_fin = 2561.628 uV 22:29:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.060 uVs 22:29:40 Integrated Voltage Measurement... 22:29:49 Voltage Offset Correction: v_off_ini = 2602.796 uV, v_off_fin = 2588.016 uV 22:29:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.339 uVs 22:29:49 Integrated Voltage Measurement... 22:29:58 Voltage Offset Correction: v_off_ini = 2594.048 uV, v_off_fin = 2597.384 uV 22:29:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.585 uVs 22:29:58 Integrated Voltage Measurement... 22:30:07 Voltage Offset Correction: v_off_ini = 2601.716 uV, v_off_fin = 2612.007 uV 22:30:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.745 uVs 22:30:10 I2Y Average and RMS of Measurements VT = -204.618 +- 5.849 uVs I2Y = -18.825 +- 0.538 uTm^2 22:30:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:30:18 Integrated Voltage Measurement... 22:30:27 Voltage Offset Correction: v_off_ini = 2582.754 uV, v_off_fin = 2587.177 uV 22:30:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.779 uVs 22:30:27 Integrated Voltage Measurement... 22:30:36 Voltage Offset Correction: v_off_ini = 2610.539 uV, v_off_fin = 2593.579 uV 22:30:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.203 uVs 22:30:36 Integrated Voltage Measurement... 22:30:45 Voltage Offset Correction: v_off_ini = 2584.550 uV, v_off_fin = 2605.137 uV 22:30:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.648 uVs 22:30:45 Integrated Voltage Measurement... 22:30:54 Voltage Offset Correction: v_off_ini = 2620.090 uV, v_off_fin = 2607.883 uV 22:30:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.158 uVs 22:30:54 Integrated Voltage Measurement... 22:31:03 Voltage Offset Correction: v_off_ini = 2613.401 uV, v_off_fin = 2614.878 uV 22:31:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.044 uVs 22:31:03 Integrated Voltage Measurement... 22:31:12 Voltage Offset Correction: v_off_ini = 2622.643 uV, v_off_fin = 2602.931 uV 22:31:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.175 uVs 22:31:16 I1X Average and RMS of Measurements VT = -83.001 +- 4.180 uVs I1X = 16.601 +- 0.836 uTm 22:31:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:31:23 Integrated Voltage Measurement... 22:31:32 Voltage Offset Correction: v_off_ini = 2617.009 uV, v_off_fin = 2609.983 uV 22:31:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.697 uVs 22:31:32 Integrated Voltage Measurement... 22:31:41 Voltage Offset Correction: v_off_ini = 2619.257 uV, v_off_fin = 2626.933 uV 22:31:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.045 uVs 22:31:41 Integrated Voltage Measurement... 22:31:50 Voltage Offset Correction: v_off_ini = 2621.687 uV, v_off_fin = 2617.172 uV 22:31:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.193 uVs 22:31:50 Integrated Voltage Measurement... 22:31:59 Voltage Offset Correction: v_off_ini = 2627.991 uV, v_off_fin = 2629.328 uV 22:31:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.628 uVs 22:31:59 Integrated Voltage Measurement... 22:32:08 Voltage Offset Correction: v_off_ini = 2614.220 uV, v_off_fin = 2609.497 uV 22:32:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.451 uVs 22:32:08 Integrated Voltage Measurement... 22:32:17 Voltage Offset Correction: v_off_ini = 2647.670 uV, v_off_fin = 2641.983 uV 22:32:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.205 uVs 22:32:21 I1Y Average and RMS of Measurements VT = -206.870 +- 3.248 uVs I1Y = -41.374 +- 0.650 uTm 22:32:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:32:26 Integrated Voltage Measurement... 22:32:35 Voltage Offset Correction: v_off_ini = 2624.383 uV, v_off_fin = 2610.700 uV 22:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.603 uVs 22:32:35 Integrated Voltage Measurement... 22:32:44 Voltage Offset Correction: v_off_ini = 2605.643 uV, v_off_fin = 2628.520 uV 22:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.170 uVs 22:32:44 Integrated Voltage Measurement... 22:32:53 Voltage Offset Correction: v_off_ini = 2619.579 uV, v_off_fin = 2611.918 uV 22:32:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.189 uVs 22:32:53 Integrated Voltage Measurement... 22:33:02 Voltage Offset Correction: v_off_ini = 2593.075 uV, v_off_fin = 2630.742 uV 22:33:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 48.548 uVs 22:33:02 Integrated Voltage Measurement... 22:33:11 Voltage Offset Correction: v_off_ini = 2612.944 uV, v_off_fin = 2613.194 uV 22:33:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.393 uVs 22:33:11 Integrated Voltage Measurement... 22:33:20 Voltage Offset Correction: v_off_ini = 2609.520 uV, v_off_fin = 2618.443 uV 22:33:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.984 uVs 22:33:23 I2X Average and RMS of Measurements VT = -52.981 +- 9.066 uVs I2X = 4.874 +- 0.834 uTm^2 22:33:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:33:28 Integrated Voltage Measurement... 22:33:37 Voltage Offset Correction: v_off_ini = 2631.734 uV, v_off_fin = 2637.875 uV 22:33:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.281 uVs 22:33:37 Integrated Voltage Measurement... 22:33:46 Voltage Offset Correction: v_off_ini = 2628.977 uV, v_off_fin = 2650.062 uV 22:33:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.734 uVs 22:33:46 Integrated Voltage Measurement... 22:33:55 Voltage Offset Correction: v_off_ini = 2638.639 uV, v_off_fin = 2648.329 uV 22:33:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.294 uVs 22:33:55 Integrated Voltage Measurement... 22:34:04 Voltage Offset Correction: v_off_ini = 2657.945 uV, v_off_fin = 2634.795 uV 22:34:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.984 uVs 22:34:04 Integrated Voltage Measurement... 22:34:13 Voltage Offset Correction: v_off_ini = 2643.241 uV, v_off_fin = 2642.193 uV 22:34:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.217 uVs 22:34:13 Integrated Voltage Measurement... 22:34:22 Voltage Offset Correction: v_off_ini = 2654.924 uV, v_off_fin = 2626.782 uV 22:34:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.218 uVs 22:34:25 I2Y Average and RMS of Measurements VT = -204.288 +- 7.261 uVs I2Y = -18.795 +- 0.668 uTm^2 22:34:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 22:34:33 Integrated Voltage Measurement... 22:34:42 Voltage Offset Correction: v_off_ini = 2639.716 uV, v_off_fin = 2641.638 uV 22:34:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -71.844 uVs 22:34:42 Integrated Voltage Measurement... 22:34:51 Voltage Offset Correction: v_off_ini = 2649.878 uV, v_off_fin = 2617.018 uV 22:34:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.330 uVs 22:34:51 Integrated Voltage Measurement... 22:35:00 Voltage Offset Correction: v_off_ini = 2603.993 uV, v_off_fin = 2595.829 uV 22:35:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.283 uVs 22:35:00 Integrated Voltage Measurement... 22:35:09 Voltage Offset Correction: v_off_ini = 2607.686 uV, v_off_fin = 2584.640 uV 22:35:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.652 uVs 22:35:09 Integrated Voltage Measurement... 22:35:18 Voltage Offset Correction: v_off_ini = 2593.569 uV, v_off_fin = 2618.178 uV 22:35:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.284 uVs 22:35:18 Integrated Voltage Measurement... 22:35:27 Voltage Offset Correction: v_off_ini = 2618.028 uV, v_off_fin = 2627.152 uV 22:35:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.585 uVs 22:35:31 I1X Average and RMS of Measurements VT = -67.996 +- 3.124 uVs I1X = 13.600 +- 0.624 uTm 22:35:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 22:35:38 Integrated Voltage Measurement... 22:35:47 Voltage Offset Correction: v_off_ini = 2622.624 uV, v_off_fin = 2599.679 uV 22:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.814 uVs 22:35:47 Integrated Voltage Measurement... 22:35:56 Voltage Offset Correction: v_off_ini = 2614.178 uV, v_off_fin = 2616.464 uV 22:35:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.281 uVs 22:35:56 Integrated Voltage Measurement... 22:36:05 Voltage Offset Correction: v_off_ini = 2601.958 uV, v_off_fin = 2600.618 uV 22:36:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.805 uVs 22:36:05 Integrated Voltage Measurement... 22:36:14 Voltage Offset Correction: v_off_ini = 2605.841 uV, v_off_fin = 2608.779 uV 22:36:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.781 uVs 22:36:14 Integrated Voltage Measurement... 22:36:23 Voltage Offset Correction: v_off_ini = 2599.919 uV, v_off_fin = 2602.477 uV 22:36:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.344 uVs 22:36:23 Integrated Voltage Measurement... 22:36:32 Voltage Offset Correction: v_off_ini = 2584.058 uV, v_off_fin = 2606.250 uV 22:36:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.683 uVs 22:36:36 I1Y Average and RMS of Measurements VT = -208.285 +- 4.623 uVs I1Y = -41.655 +- 0.923 uTm 22:36:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 22:36:41 Integrated Voltage Measurement... 22:36:50 Voltage Offset Correction: v_off_ini = 2579.192 uV, v_off_fin = 2567.385 uV 22:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.843 uVs 22:36:50 Integrated Voltage Measurement... 22:36:59 Voltage Offset Correction: v_off_ini = 2572.122 uV, v_off_fin = 2609.395 uV 22:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.509 uVs 22:36:59 Integrated Voltage Measurement... 22:37:08 Voltage Offset Correction: v_off_ini = 2610.108 uV, v_off_fin = 2615.545 uV 22:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.896 uVs 22:37:08 Integrated Voltage Measurement... 22:37:17 Voltage Offset Correction: v_off_ini = 2593.827 uV, v_off_fin = 2589.060 uV 22:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.965 uVs 22:37:17 Integrated Voltage Measurement... 22:37:26 Voltage Offset Correction: v_off_ini = 2588.219 uV, v_off_fin = 2578.500 uV 22:37:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.985 uVs 22:37:26 Integrated Voltage Measurement... 22:37:35 Voltage Offset Correction: v_off_ini = 2581.318 uV, v_off_fin = 2599.784 uV 22:37:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.774 uVs 22:37:38 I2X Average and RMS of Measurements VT = -51.828 +- 4.640 uVs I2X = 4.768 +- 0.427 uTm^2 22:37:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 22:37:43 Integrated Voltage Measurement... 22:37:52 Voltage Offset Correction: v_off_ini = 2593.198 uV, v_off_fin = 2599.510 uV 22:37:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.762 uVs 22:37:52 Integrated Voltage Measurement... 22:38:01 Voltage Offset Correction: v_off_ini = 2622.327 uV, v_off_fin = 2596.338 uV 22:38:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.964 uVs 22:38:01 Integrated Voltage Measurement... 22:38:10 Voltage Offset Correction: v_off_ini = 2596.869 uV, v_off_fin = 2591.578 uV 22:38:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.887 uVs 22:38:10 Integrated Voltage Measurement... 22:38:19 Voltage Offset Correction: v_off_ini = 2584.384 uV, v_off_fin = 2577.687 uV 22:38:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.407 uVs 22:38:19 Integrated Voltage Measurement... 22:38:28 Voltage Offset Correction: v_off_ini = 2572.589 uV, v_off_fin = 2575.603 uV 22:38:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.355 uVs 22:38:28 Integrated Voltage Measurement... 22:38:37 Voltage Offset Correction: v_off_ini = 2578.679 uV, v_off_fin = 2573.335 uV 22:38:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.947 uVs 22:38:39 I2Y Average and RMS of Measurements VT = -202.387 +- 1.152 uVs I2Y = -18.620 +- 0.106 uTm^2 22:38:43 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 22:38:47 Integrated Voltage Measurement... 22:38:56 Voltage Offset Correction: v_off_ini = 2597.107 uV, v_off_fin = 2593.076 uV 22:38:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.646 uVs 22:38:56 Integrated Voltage Measurement... 22:39:05 Voltage Offset Correction: v_off_ini = 2583.474 uV, v_off_fin = 2579.495 uV 22:39:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.806 uVs 22:39:05 Integrated Voltage Measurement... 22:39:14 Voltage Offset Correction: v_off_ini = 2570.450 uV, v_off_fin = 2575.436 uV 22:39:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.036 uVs 22:39:14 Integrated Voltage Measurement... 22:39:23 Voltage Offset Correction: v_off_ini = 2569.989 uV, v_off_fin = 2571.294 uV 22:39:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.392 uVs 22:39:23 Integrated Voltage Measurement... 22:39:32 Voltage Offset Correction: v_off_ini = 2575.704 uV, v_off_fin = 2551.510 uV 22:39:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.794 uVs 22:39:33 Integrated Voltage Measurement... 22:39:41 Voltage Offset Correction: v_off_ini = 2539.865 uV, v_off_fin = 2569.469 uV 22:39:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 75.875 uVs 22:39:46 I1X Average and RMS of Measurements VT = -67.591 +- 15.456 uVs I1X = 13.519 +- 3.092 uTm 22:39:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 22:39:52 Integrated Voltage Measurement... 22:40:01 Voltage Offset Correction: v_off_ini = 2556.009 uV, v_off_fin = 2548.069 uV 22:40:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.636 uVs 22:40:01 Integrated Voltage Measurement... 22:40:10 Voltage Offset Correction: v_off_ini = 2568.510 uV, v_off_fin = 2575.031 uV 22:40:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.754 uVs 22:40:10 Integrated Voltage Measurement... 22:40:19 Voltage Offset Correction: v_off_ini = 2565.771 uV, v_off_fin = 2554.163 uV 22:40:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.495 uVs 22:40:19 Integrated Voltage Measurement... 22:40:28 Voltage Offset Correction: v_off_ini = 2583.148 uV, v_off_fin = 2601.923 uV 22:40:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.868 uVs 22:40:28 Integrated Voltage Measurement... 22:40:37 Voltage Offset Correction: v_off_ini = 2599.611 uV, v_off_fin = 2573.222 uV 22:40:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.601 uVs 22:40:37 Integrated Voltage Measurement... 22:40:46 Voltage Offset Correction: v_off_ini = 2608.929 uV, v_off_fin = 2609.447 uV 22:40:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.574 uVs 22:40:51 I1Y Average and RMS of Measurements VT = -200.655 +- 6.777 uVs I1Y = -40.127 +- 1.355 uTm 22:40:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 22:40:56 Integrated Voltage Measurement... 22:41:05 Voltage Offset Correction: v_off_ini = 2578.862 uV, v_off_fin = 2566.113 uV 22:41:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.052 uVs 22:41:05 Integrated Voltage Measurement... 22:41:14 Voltage Offset Correction: v_off_ini = 2566.061 uV, v_off_fin = 2569.815 uV 22:41:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.855 uVs 22:41:14 Integrated Voltage Measurement... 22:41:23 Voltage Offset Correction: v_off_ini = 2553.787 uV, v_off_fin = 2547.558 uV 22:41:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.559 uVs 22:41:23 Integrated Voltage Measurement... 22:41:32 Voltage Offset Correction: v_off_ini = 2574.317 uV, v_off_fin = 2593.409 uV 22:41:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.871 uVs 22:41:32 Integrated Voltage Measurement... 22:41:41 Voltage Offset Correction: v_off_ini = 2571.342 uV, v_off_fin = 2552.245 uV 22:41:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.463 uVs 22:41:41 Integrated Voltage Measurement... 22:41:50 Voltage Offset Correction: v_off_ini = 2586.644 uV, v_off_fin = 2585.636 uV 22:41:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.980 uVs 22:41:52 I2X Average and RMS of Measurements VT = -66.130 +- 2.563 uVs I2X = 6.084 +- 0.236 uTm^2 22:41:55 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 22:41:57 Integrated Voltage Measurement... 22:42:06 Voltage Offset Correction: v_off_ini = 2581.407 uV, v_off_fin = 2576.264 uV 22:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.720 uVs 22:42:06 Integrated Voltage Measurement... 22:42:15 Voltage Offset Correction: v_off_ini = 2598.015 uV, v_off_fin = 2577.796 uV 22:42:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.721 uVs 22:42:15 Integrated Voltage Measurement... 22:42:24 Voltage Offset Correction: v_off_ini = 2593.172 uV, v_off_fin = 2581.670 uV 22:42:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.496 uVs 22:42:24 Integrated Voltage Measurement... 22:42:33 Voltage Offset Correction: v_off_ini = 2575.380 uV, v_off_fin = 2581.900 uV 22:42:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 177.726 uVs 22:42:33 Integrated Voltage Measurement... 22:42:42 Voltage Offset Correction: v_off_ini = 2574.010 uV, v_off_fin = 2582.932 uV 22:42:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.546 uVs 22:42:42 Integrated Voltage Measurement... 22:42:51 Voltage Offset Correction: v_off_ini = 2579.870 uV, v_off_fin = 2580.208 uV 22:42:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.825 uVs 22:42:54 I2Y Average and RMS of Measurements VT = -200.839 +- 9.306 uVs I2Y = -18.477 +- 0.856 uTm^2 22:42:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm