SLAC Magnetic Measurements Date: 07-31-2026 Time: 10:50:12 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16334 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 10:50:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:50:22 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:50:24 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:50:25 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:50:27 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:50:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:50:41 Integrated Voltage Measurement... 10:50:50 Voltage Offset Correction: v_off_ini = 2287.802 uV, v_off_fin = 2271.022 uV 10:50:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -102.225 uVs 10:50:50 Integrated Voltage Measurement... 10:50:59 Voltage Offset Correction: v_off_ini = 2274.254 uV, v_off_fin = 2272.397 uV 10:50:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.463 uVs 10:50:59 Integrated Voltage Measurement... 10:51:08 Voltage Offset Correction: v_off_ini = 2300.284 uV, v_off_fin = 2288.085 uV 10:51:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.390 uVs 10:51:08 Integrated Voltage Measurement... 10:51:17 Voltage Offset Correction: v_off_ini = 2294.035 uV, v_off_fin = 2298.823 uV 10:51:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.066 uVs 10:51:17 Integrated Voltage Measurement... 10:51:26 Voltage Offset Correction: v_off_ini = 2293.862 uV, v_off_fin = 2305.139 uV 10:51:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.129 uVs 10:51:26 Integrated Voltage Measurement... 10:51:35 Voltage Offset Correction: v_off_ini = 2319.385 uV, v_off_fin = 2326.054 uV 10:51:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.665 uVs 10:51:40 I1X Average and RMS of Measurements VT = -130.323 +- 6.449 uVs I1X = 26.065 +- 1.289 uTm 10:51:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:51:46 Integrated Voltage Measurement... 10:51:55 Voltage Offset Correction: v_off_ini = 2317.205 uV, v_off_fin = 2314.090 uV 10:51:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.258 uVs 10:51:55 Integrated Voltage Measurement... 10:52:04 Voltage Offset Correction: v_off_ini = 2290.002 uV, v_off_fin = 2290.742 uV 10:52:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.767 uVs 10:52:04 Integrated Voltage Measurement... 10:52:13 Voltage Offset Correction: v_off_ini = 2286.618 uV, v_off_fin = 2293.113 uV 10:52:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.200 uVs 10:52:13 Integrated Voltage Measurement... 10:52:22 Voltage Offset Correction: v_off_ini = 2317.430 uV, v_off_fin = 2328.152 uV 10:52:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.326 uVs 10:52:22 Integrated Voltage Measurement... 10:52:31 Voltage Offset Correction: v_off_ini = 2286.012 uV, v_off_fin = 2287.374 uV 10:52:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.141 uVs 10:52:31 Integrated Voltage Measurement... 10:52:40 Voltage Offset Correction: v_off_ini = 2282.518 uV, v_off_fin = 2303.506 uV 10:52:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.353 uVs 10:52:45 I1Y Average and RMS of Measurements VT = -250.508 +- 11.516 uVs I1Y = -50.102 +- 2.303 uTm 10:52:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:52:52 Integrated Voltage Measurement... 10:53:01 Voltage Offset Correction: v_off_ini = 2306.403 uV, v_off_fin = 2309.089 uV 10:53:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.587 uVs 10:53:01 Integrated Voltage Measurement... 10:53:10 Voltage Offset Correction: v_off_ini = 2312.634 uV, v_off_fin = 2297.363 uV 10:53:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.188 uVs 10:53:10 Integrated Voltage Measurement... 10:53:19 Voltage Offset Correction: v_off_ini = 2282.933 uV, v_off_fin = 2253.396 uV 10:53:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.012 uVs 10:53:19 Integrated Voltage Measurement... 10:53:28 Voltage Offset Correction: v_off_ini = 2266.432 uV, v_off_fin = 2277.233 uV 10:53:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.391 uVs 10:53:28 Integrated Voltage Measurement... 10:53:37 Voltage Offset Correction: v_off_ini = 2268.756 uV, v_off_fin = 2286.933 uV 10:53:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.470 uVs 10:53:37 Integrated Voltage Measurement... 10:53:46 Voltage Offset Correction: v_off_ini = 2289.435 uV, v_off_fin = 2266.430 uV 10:53:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 165.447 uVs 10:53:49 I2X Average and RMS of Measurements VT = -132.016 +- 14.212 uVs I2X = 12.146 +- 1.308 uTm^2 10:53:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:53:56 Integrated Voltage Measurement... 10:54:05 Voltage Offset Correction: v_off_ini = 2295.895 uV, v_off_fin = 2293.386 uV 10:54:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -414.463 uVs 10:54:05 Integrated Voltage Measurement... 10:54:14 Voltage Offset Correction: v_off_ini = 2284.331 uV, v_off_fin = 2299.279 uV 10:54:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 423.040 uVs 10:54:14 Integrated Voltage Measurement... 10:54:23 Voltage Offset Correction: v_off_ini = 2283.453 uV, v_off_fin = 2286.444 uV 10:54:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -404.930 uVs 10:54:23 Integrated Voltage Measurement... 10:54:32 Voltage Offset Correction: v_off_ini = 2301.587 uV, v_off_fin = 2294.358 uV 10:54:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 413.182 uVs 10:54:33 Integrated Voltage Measurement... 10:54:42 Voltage Offset Correction: v_off_ini = 2301.809 uV, v_off_fin = 2287.520 uV 10:54:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -398.852 uVs 10:54:42 Integrated Voltage Measurement... 10:54:51 Voltage Offset Correction: v_off_ini = 2282.068 uV, v_off_fin = 2254.972 uV 10:54:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 426.200 uVs 10:54:53 I2Y Average and RMS of Measurements VT = -413.444 +- 4.011 uVs I2Y = -38.037 +- 0.369 uTm^2 10:55:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:55:08 Integrated Voltage Measurement... 10:55:17 Voltage Offset Correction: v_off_ini = 2307.127 uV, v_off_fin = 2285.910 uV 10:55:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.166 uVs 10:55:17 Integrated Voltage Measurement... 10:55:26 Voltage Offset Correction: v_off_ini = 2304.892 uV, v_off_fin = 2291.284 uV 10:55:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.502 uVs 10:55:26 Integrated Voltage Measurement... 10:55:35 Voltage Offset Correction: v_off_ini = 2275.597 uV, v_off_fin = 2242.030 uV 10:55:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.881 uVs 10:55:35 Integrated Voltage Measurement... 10:55:44 Voltage Offset Correction: v_off_ini = 2259.689 uV, v_off_fin = 2268.611 uV 10:55:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.507 uVs 10:55:44 Integrated Voltage Measurement... 10:55:53 Voltage Offset Correction: v_off_ini = 2261.358 uV, v_off_fin = 2242.708 uV 10:55:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.045 uVs 10:55:53 Integrated Voltage Measurement... 10:56:02 Voltage Offset Correction: v_off_ini = 2250.698 uV, v_off_fin = 2247.969 uV 10:56:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.007 uVs 10:56:06 I1X Average and RMS of Measurements VT = -120.018 +- 7.680 uVs I1X = 24.004 +- 1.536 uTm 10:56:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:56:13 Integrated Voltage Measurement... 10:56:22 Voltage Offset Correction: v_off_ini = 2251.096 uV, v_off_fin = 2238.096 uV 10:56:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -274.854 uVs 10:56:22 Integrated Voltage Measurement... 10:56:31 Voltage Offset Correction: v_off_ini = 2266.507 uV, v_off_fin = 2279.399 uV 10:56:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.375 uVs 10:56:31 Integrated Voltage Measurement... 10:56:40 Voltage Offset Correction: v_off_ini = 2254.703 uV, v_off_fin = 2264.243 uV 10:56:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.652 uVs 10:56:40 Integrated Voltage Measurement... 10:56:49 Voltage Offset Correction: v_off_ini = 2274.925 uV, v_off_fin = 2300.228 uV 10:56:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 253.704 uVs 10:56:49 Integrated Voltage Measurement... 10:56:58 Voltage Offset Correction: v_off_ini = 2295.487 uV, v_off_fin = 2266.597 uV 10:56:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.282 uVs 10:56:58 Integrated Voltage Measurement... 10:57:07 Voltage Offset Correction: v_off_ini = 2281.934 uV, v_off_fin = 2287.748 uV 10:57:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.552 uVs 10:57:11 I1Y Average and RMS of Measurements VT = -252.403 +- 7.382 uVs I1Y = -50.481 +- 1.476 uTm 10:57:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:57:19 Integrated Voltage Measurement... 10:57:28 Voltage Offset Correction: v_off_ini = 2248.785 uV, v_off_fin = 2242.605 uV 10:57:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.033 uVs 10:57:28 Integrated Voltage Measurement... 10:57:37 Voltage Offset Correction: v_off_ini = 2275.759 uV, v_off_fin = 2281.828 uV 10:57:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.783 uVs 10:57:37 Integrated Voltage Measurement... 10:57:46 Voltage Offset Correction: v_off_ini = 2250.579 uV, v_off_fin = 2237.845 uV 10:57:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.572 uVs 10:57:46 Integrated Voltage Measurement... 10:57:55 Voltage Offset Correction: v_off_ini = 2247.918 uV, v_off_fin = 2282.309 uV 10:57:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.834 uVs 10:57:55 Integrated Voltage Measurement... 10:58:04 Voltage Offset Correction: v_off_ini = 2268.895 uV, v_off_fin = 2247.079 uV 10:58:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.145 uVs 10:58:04 Integrated Voltage Measurement... 10:58:13 Voltage Offset Correction: v_off_ini = 2266.199 uV, v_off_fin = 2266.592 uV 10:58:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.333 uVs 10:58:15 I2X Average and RMS of Measurements VT = -132.450 +- 6.057 uVs I2X = 12.185 +- 0.557 uTm^2 10:58:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:58:23 Integrated Voltage Measurement... 10:58:32 Voltage Offset Correction: v_off_ini = 2272.249 uV, v_off_fin = 2279.553 uV 10:58:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -407.400 uVs 10:58:32 Integrated Voltage Measurement... 10:58:41 Voltage Offset Correction: v_off_ini = 2266.828 uV, v_off_fin = 2290.385 uV 10:58:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 397.781 uVs 10:58:41 Integrated Voltage Measurement... 10:58:50 Voltage Offset Correction: v_off_ini = 2255.971 uV, v_off_fin = 2273.568 uV 10:58:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -418.164 uVs 10:58:50 Integrated Voltage Measurement... 10:58:59 Voltage Offset Correction: v_off_ini = 2287.479 uV, v_off_fin = 2307.574 uV 10:58:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 408.205 uVs 10:58:59 Integrated Voltage Measurement... 10:59:08 Voltage Offset Correction: v_off_ini = 2305.887 uV, v_off_fin = 2302.612 uV 10:59:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -417.892 uVs 10:59:08 Integrated Voltage Measurement... 10:59:17 Voltage Offset Correction: v_off_ini = 2300.209 uV, v_off_fin = 2290.536 uV 10:59:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.335 uVs 10:59:19 I2Y Average and RMS of Measurements VT = -406.796 +- 4.592 uVs I2Y = -37.425 +- 0.422 uTm^2 10:59:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:59:34 Integrated Voltage Measurement... 10:59:43 Voltage Offset Correction: v_off_ini = 2248.747 uV, v_off_fin = 2246.201 uV 10:59:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -97.231 uVs 10:59:43 Integrated Voltage Measurement... 10:59:52 Voltage Offset Correction: v_off_ini = 2234.515 uV, v_off_fin = 2270.536 uV 10:59:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.033 uVs 10:59:52 Integrated Voltage Measurement... 11:00:01 Voltage Offset Correction: v_off_ini = 2271.564 uV, v_off_fin = 2261.087 uV 11:00:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.785 uVs 11:00:01 Integrated Voltage Measurement... 11:00:10 Voltage Offset Correction: v_off_ini = 2261.553 uV, v_off_fin = 2259.097 uV 11:00:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.324 uVs 11:00:10 Integrated Voltage Measurement... 11:00:19 Voltage Offset Correction: v_off_ini = 2280.446 uV, v_off_fin = 2267.490 uV 11:00:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.521 uVs 11:00:19 Integrated Voltage Measurement... 11:00:28 Voltage Offset Correction: v_off_ini = 2287.870 uV, v_off_fin = 2298.349 uV 11:00:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.143 uVs 11:00:33 I1X Average and RMS of Measurements VT = -113.840 +- 2.571 uVs I1X = 22.770 +- 0.514 uTm 11:00:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:00:39 Integrated Voltage Measurement... 11:00:48 Voltage Offset Correction: v_off_ini = 2284.623 uV, v_off_fin = 2285.758 uV 11:00:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.682 uVs 11:00:48 Integrated Voltage Measurement... 11:00:57 Voltage Offset Correction: v_off_ini = 2274.236 uV, v_off_fin = 2274.936 uV 11:00:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.597 uVs 11:00:57 Integrated Voltage Measurement... 11:01:06 Voltage Offset Correction: v_off_ini = 2258.123 uV, v_off_fin = 2231.841 uV 11:01:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.657 uVs 11:01:06 Integrated Voltage Measurement... 11:01:15 Voltage Offset Correction: v_off_ini = 2249.450 uV, v_off_fin = 2271.264 uV 11:01:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.407 uVs 11:01:15 Integrated Voltage Measurement... 11:01:24 Voltage Offset Correction: v_off_ini = 2289.952 uV, v_off_fin = 2271.348 uV 11:01:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.266 uVs 11:01:24 Integrated Voltage Measurement... 11:01:33 Voltage Offset Correction: v_off_ini = 2285.260 uV, v_off_fin = 2299.525 uV 11:01:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.909 uVs 11:01:37 I1Y Average and RMS of Measurements VT = -242.586 +- 8.559 uVs I1Y = -48.517 +- 1.712 uTm 11:01:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:01:45 Integrated Voltage Measurement... 11:01:54 Voltage Offset Correction: v_off_ini = 2284.579 uV, v_off_fin = 2287.025 uV 11:01:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -135.035 uVs 11:01:54 Integrated Voltage Measurement... 11:02:03 Voltage Offset Correction: v_off_ini = 2284.754 uV, v_off_fin = 2269.933 uV 11:02:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.944 uVs 11:02:03 Integrated Voltage Measurement... 11:02:12 Voltage Offset Correction: v_off_ini = 2250.465 uV, v_off_fin = 2230.328 uV 11:02:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.281 uVs 11:02:12 Integrated Voltage Measurement... 11:02:21 Voltage Offset Correction: v_off_ini = 2246.478 uV, v_off_fin = 2273.559 uV 11:02:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.923 uVs 11:02:21 Integrated Voltage Measurement... 11:02:30 Voltage Offset Correction: v_off_ini = 2258.689 uV, v_off_fin = 2219.739 uV 11:02:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.046 uVs 11:02:30 Integrated Voltage Measurement... 11:02:39 Voltage Offset Correction: v_off_ini = 2228.184 uV, v_off_fin = 2244.406 uV 11:02:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.855 uVs 11:02:42 I2X Average and RMS of Measurements VT = -123.514 +- 14.537 uVs I2X = 11.363 +- 1.337 uTm^2 11:02:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:02:49 Integrated Voltage Measurement... 11:02:58 Voltage Offset Correction: v_off_ini = 2264.731 uV, v_off_fin = 2266.003 uV 11:02:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.372 uVs 11:02:58 Integrated Voltage Measurement... 11:03:07 Voltage Offset Correction: v_off_ini = 2245.256 uV, v_off_fin = 2263.871 uV 11:03:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 396.803 uVs 11:03:07 Integrated Voltage Measurement... 11:03:16 Voltage Offset Correction: v_off_ini = 2248.764 uV, v_off_fin = 2248.496 uV 11:03:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -363.270 uVs 11:03:16 Integrated Voltage Measurement... 11:03:25 Voltage Offset Correction: v_off_ini = 2238.744 uV, v_off_fin = 2242.374 uV 11:03:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 396.295 uVs 11:03:25 Integrated Voltage Measurement... 11:03:34 Voltage Offset Correction: v_off_ini = 2236.014 uV, v_off_fin = 2233.004 uV 11:03:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -354.407 uVs 11:03:34 Integrated Voltage Measurement... 11:03:43 Voltage Offset Correction: v_off_ini = 2227.235 uV, v_off_fin = 2233.845 uV 11:03:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.484 uVs 11:03:46 I2Y Average and RMS of Measurements VT = -373.772 +- 11.298 uVs I2Y = -34.389 +- 1.039 uTm^2 11:03:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:04:01 Integrated Voltage Measurement... 11:04:10 Voltage Offset Correction: v_off_ini = 2263.094 uV, v_off_fin = 2228.288 uV 11:04:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -99.466 uVs 11:04:10 Integrated Voltage Measurement... 11:04:19 Voltage Offset Correction: v_off_ini = 2228.230 uV, v_off_fin = 2231.547 uV 11:04:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.813 uVs 11:04:19 Integrated Voltage Measurement... 11:04:28 Voltage Offset Correction: v_off_ini = 2244.084 uV, v_off_fin = 2257.231 uV 11:04:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.651 uVs 11:04:28 Integrated Voltage Measurement... 11:04:37 Voltage Offset Correction: v_off_ini = 2244.459 uV, v_off_fin = 2259.723 uV 11:04:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.024 uVs 11:04:37 Integrated Voltage Measurement... 11:04:46 Voltage Offset Correction: v_off_ini = 2236.857 uV, v_off_fin = 2231.557 uV 11:04:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.218 uVs 11:04:46 Integrated Voltage Measurement... 11:04:55 Voltage Offset Correction: v_off_ini = 2221.713 uV, v_off_fin = 2229.015 uV 11:04:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.573 uVs 11:04:59 I1X Average and RMS of Measurements VT = -105.458 +- 4.341 uVs I1X = 21.093 +- 0.867 uTm 11:05:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:05:06 Integrated Voltage Measurement... 11:05:15 Voltage Offset Correction: v_off_ini = 2218.541 uV, v_off_fin = 2193.998 uV 11:05:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -228.615 uVs 11:05:15 Integrated Voltage Measurement... 11:05:24 Voltage Offset Correction: v_off_ini = 2175.087 uV, v_off_fin = 2193.391 uV 11:05:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.297 uVs 11:05:24 Integrated Voltage Measurement... 11:05:33 Voltage Offset Correction: v_off_ini = 2210.224 uV, v_off_fin = 2212.105 uV 11:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.190 uVs 11:05:33 Integrated Voltage Measurement... 11:05:42 Voltage Offset Correction: v_off_ini = 2237.077 uV, v_off_fin = 2240.712 uV 11:05:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.618 uVs 11:05:42 Integrated Voltage Measurement... 11:05:51 Voltage Offset Correction: v_off_ini = 2226.101 uV, v_off_fin = 2231.091 uV 11:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.279 uVs 11:05:51 Integrated Voltage Measurement... 11:06:00 Voltage Offset Correction: v_off_ini = 2245.822 uV, v_off_fin = 2253.923 uV 11:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.088 uVs 11:06:04 I1Y Average and RMS of Measurements VT = -227.348 +- 9.977 uVs I1Y = -45.470 +- 1.996 uTm 11:06:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:06:12 Integrated Voltage Measurement... 11:06:21 Voltage Offset Correction: v_off_ini = 2238.698 uV, v_off_fin = 2215.454 uV 11:06:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.896 uVs 11:06:21 Integrated Voltage Measurement... 11:06:30 Voltage Offset Correction: v_off_ini = 2219.002 uV, v_off_fin = 2244.044 uV 11:06:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 180.318 uVs 11:06:30 Integrated Voltage Measurement... 11:06:39 Voltage Offset Correction: v_off_ini = 2248.142 uV, v_off_fin = 2215.222 uV 11:06:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.830 uVs 11:06:39 Integrated Voltage Measurement... 11:06:48 Voltage Offset Correction: v_off_ini = 2242.220 uV, v_off_fin = 2254.873 uV 11:06:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.668 uVs 11:06:48 Integrated Voltage Measurement... 11:06:57 Voltage Offset Correction: v_off_ini = 2248.052 uV, v_off_fin = 2241.605 uV 11:06:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -136.762 uVs 11:06:57 Integrated Voltage Measurement... 11:07:06 Voltage Offset Correction: v_off_ini = 2245.087 uV, v_off_fin = 2248.825 uV 11:07:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.556 uVs 11:07:08 I2X Average and RMS of Measurements VT = -130.172 +- 9.697 uVs I2X = 11.976 +- 0.892 uTm^2 11:07:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:07:16 Integrated Voltage Measurement... 11:07:25 Voltage Offset Correction: v_off_ini = 2236.113 uV, v_off_fin = 2210.895 uV 11:07:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.527 uVs 11:07:25 Integrated Voltage Measurement... 11:07:34 Voltage Offset Correction: v_off_ini = 2218.246 uV, v_off_fin = 2224.791 uV 11:07:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 380.210 uVs 11:07:34 Integrated Voltage Measurement... 11:07:43 Voltage Offset Correction: v_off_ini = 2217.311 uV, v_off_fin = 2238.723 uV 11:07:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -377.700 uVs 11:07:43 Integrated Voltage Measurement... 11:07:52 Voltage Offset Correction: v_off_ini = 2220.601 uV, v_off_fin = 2218.505 uV 11:07:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 381.938 uVs 11:07:52 Integrated Voltage Measurement... 11:08:01 Voltage Offset Correction: v_off_ini = 2231.573 uV, v_off_fin = 2217.430 uV 11:08:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -370.259 uVs 11:08:01 Integrated Voltage Measurement... 11:08:10 Voltage Offset Correction: v_off_ini = 2269.279 uV, v_off_fin = 2249.129 uV 11:08:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.951 uVs 11:08:12 I2Y Average and RMS of Measurements VT = -373.431 +- 5.756 uVs I2Y = -34.357 +- 0.530 uTm^2 11:08:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:08:30 Integrated Voltage Measurement... 11:08:39 Voltage Offset Correction: v_off_ini = 2250.748 uV, v_off_fin = 2262.657 uV 11:08:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.220 uVs 11:08:39 Integrated Voltage Measurement... 11:08:48 Voltage Offset Correction: v_off_ini = 2265.828 uV, v_off_fin = 2270.795 uV 11:08:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.714 uVs 11:08:48 Integrated Voltage Measurement... 11:08:57 Voltage Offset Correction: v_off_ini = 2245.549 uV, v_off_fin = 2251.565 uV 11:08:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.006 uVs 11:08:57 Integrated Voltage Measurement... 11:09:06 Voltage Offset Correction: v_off_ini = 2236.479 uV, v_off_fin = 2252.968 uV 11:09:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.512 uVs 11:09:06 Integrated Voltage Measurement... 11:09:15 Voltage Offset Correction: v_off_ini = 2225.707 uV, v_off_fin = 2231.212 uV 11:09:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.187 uVs 11:09:15 Integrated Voltage Measurement... 11:09:24 Voltage Offset Correction: v_off_ini = 2206.975 uV, v_off_fin = 2254.415 uV 11:09:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.480 uVs 11:09:28 I1X Average and RMS of Measurements VT = -105.520 +- 8.863 uVs I1X = 21.104 +- 1.773 uTm 11:09:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:09:35 Integrated Voltage Measurement... 11:09:44 Voltage Offset Correction: v_off_ini = 2237.337 uV, v_off_fin = 2236.630 uV 11:09:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.902 uVs 11:09:44 Integrated Voltage Measurement... 11:09:53 Voltage Offset Correction: v_off_ini = 2256.029 uV, v_off_fin = 2260.358 uV 11:09:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.709 uVs 11:09:53 Integrated Voltage Measurement... 11:10:02 Voltage Offset Correction: v_off_ini = 2269.223 uV, v_off_fin = 2265.959 uV 11:10:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.545 uVs 11:10:02 Integrated Voltage Measurement... 11:10:11 Voltage Offset Correction: v_off_ini = 2280.122 uV, v_off_fin = 2277.963 uV 11:10:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 233.973 uVs 11:10:11 Integrated Voltage Measurement... 11:10:19 Voltage Offset Correction: v_off_ini = 2261.750 uV, v_off_fin = 2258.106 uV 11:10:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.986 uVs 11:10:20 Integrated Voltage Measurement... 11:10:28 Voltage Offset Correction: v_off_ini = 2279.798 uV, v_off_fin = 2285.583 uV 11:10:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 215.782 uVs 11:10:33 I1Y Average and RMS of Measurements VT = -224.483 +- 8.359 uVs I1Y = -44.891 +- 1.672 uTm 11:10:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:10:40 Integrated Voltage Measurement... 11:10:49 Voltage Offset Correction: v_off_ini = 2274.883 uV, v_off_fin = 2265.714 uV 11:10:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.536 uVs 11:10:49 Integrated Voltage Measurement... 11:10:58 Voltage Offset Correction: v_off_ini = 2291.989 uV, v_off_fin = 2307.525 uV 11:10:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.405 uVs 11:10:58 Integrated Voltage Measurement... 11:11:07 Voltage Offset Correction: v_off_ini = 2294.667 uV, v_off_fin = 2277.914 uV 11:11:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.073 uVs 11:11:07 Integrated Voltage Measurement... 11:11:16 Voltage Offset Correction: v_off_ini = 2272.079 uV, v_off_fin = 2298.306 uV 11:11:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.930 uVs 11:11:17 Integrated Voltage Measurement... 11:11:25 Voltage Offset Correction: v_off_ini = 2254.765 uV, v_off_fin = 2281.444 uV 11:11:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.632 uVs 11:11:26 Integrated Voltage Measurement... 11:11:35 Voltage Offset Correction: v_off_ini = 2293.567 uV, v_off_fin = 2298.249 uV 11:11:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.838 uVs 11:11:37 I2X Average and RMS of Measurements VT = -109.402 +- 5.398 uVs I2X = 10.065 +- 0.497 uTm^2 11:11:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:11:45 Integrated Voltage Measurement... 11:11:54 Voltage Offset Correction: v_off_ini = 2280.244 uV, v_off_fin = 2289.061 uV 11:11:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -383.234 uVs 11:11:54 Integrated Voltage Measurement... 11:12:03 Voltage Offset Correction: v_off_ini = 2284.705 uV, v_off_fin = 2294.172 uV 11:12:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.516 uVs 11:12:03 Integrated Voltage Measurement... 11:12:12 Voltage Offset Correction: v_off_ini = 2305.772 uV, v_off_fin = 2318.911 uV 11:12:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -366.843 uVs 11:12:12 Integrated Voltage Measurement... 11:12:21 Voltage Offset Correction: v_off_ini = 2318.461 uV, v_off_fin = 2311.922 uV 11:12:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.639 uVs 11:12:21 Integrated Voltage Measurement... 11:12:30 Voltage Offset Correction: v_off_ini = 2335.557 uV, v_off_fin = 2330.824 uV 11:12:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -388.493 uVs 11:12:30 Integrated Voltage Measurement... 11:12:39 Voltage Offset Correction: v_off_ini = 2326.651 uV, v_off_fin = 2328.346 uV 11:12:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.762 uVs 11:12:41 I2Y Average and RMS of Measurements VT = -368.415 +- 6.487 uVs I2Y = -33.894 +- 0.597 uTm^2 11:12:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:12:56 Integrated Voltage Measurement... 11:13:05 Voltage Offset Correction: v_off_ini = 2326.526 uV, v_off_fin = 2327.935 uV 11:13:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.936 uVs 11:13:05 Integrated Voltage Measurement... 11:13:14 Voltage Offset Correction: v_off_ini = 2320.138 uV, v_off_fin = 2327.585 uV 11:13:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.731 uVs 11:13:14 Integrated Voltage Measurement... 11:13:23 Voltage Offset Correction: v_off_ini = 2331.912 uV, v_off_fin = 2327.457 uV 11:13:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.890 uVs 11:13:23 Integrated Voltage Measurement... 11:13:32 Voltage Offset Correction: v_off_ini = 2318.482 uV, v_off_fin = 2319.382 uV 11:13:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.506 uVs 11:13:32 Integrated Voltage Measurement... 11:13:41 Voltage Offset Correction: v_off_ini = 2292.861 uV, v_off_fin = 2318.370 uV 11:13:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.568 uVs 11:13:41 Integrated Voltage Measurement... 11:13:50 Voltage Offset Correction: v_off_ini = 2332.546 uV, v_off_fin = 2330.992 uV 11:13:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.212 uVs 11:13:54 I1X Average and RMS of Measurements VT = -112.974 +- 11.965 uVs I1X = 22.595 +- 2.393 uTm 11:13:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:14:01 Integrated Voltage Measurement... 11:14:10 Voltage Offset Correction: v_off_ini = 2336.600 uV, v_off_fin = 2310.700 uV 11:14:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -221.875 uVs 11:14:10 Integrated Voltage Measurement... 11:14:19 Voltage Offset Correction: v_off_ini = 2330.806 uV, v_off_fin = 2325.318 uV 11:14:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 215.180 uVs 11:14:19 Integrated Voltage Measurement... 11:14:28 Voltage Offset Correction: v_off_ini = 2349.492 uV, v_off_fin = 2339.835 uV 11:14:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.184 uVs 11:14:28 Integrated Voltage Measurement... 11:14:37 Voltage Offset Correction: v_off_ini = 2345.336 uV, v_off_fin = 2356.310 uV 11:14:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.082 uVs 11:14:37 Integrated Voltage Measurement... 11:14:46 Voltage Offset Correction: v_off_ini = 2339.500 uV, v_off_fin = 2327.784 uV 11:14:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -220.126 uVs 11:14:46 Integrated Voltage Measurement... 11:14:55 Voltage Offset Correction: v_off_ini = 2314.561 uV, v_off_fin = 2347.601 uV 11:14:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 247.718 uVs 11:14:59 I1Y Average and RMS of Measurements VT = -222.861 +- 7.882 uVs I1Y = -44.568 +- 1.573 uTm 11:15:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:15:07 Integrated Voltage Measurement... 11:15:16 Voltage Offset Correction: v_off_ini = 2325.981 uV, v_off_fin = 2328.647 uV 11:15:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -122.227 uVs 11:15:16 Integrated Voltage Measurement... 11:15:25 Voltage Offset Correction: v_off_ini = 2327.951 uV, v_off_fin = 2351.462 uV 11:15:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.010 uVs 11:15:25 Integrated Voltage Measurement... 11:15:34 Voltage Offset Correction: v_off_ini = 2356.123 uV, v_off_fin = 2342.309 uV 11:15:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.537 uVs 11:15:34 Integrated Voltage Measurement... 11:15:43 Voltage Offset Correction: v_off_ini = 2337.970 uV, v_off_fin = 2337.478 uV 11:15:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.220 uVs 11:15:43 Integrated Voltage Measurement... 11:15:52 Voltage Offset Correction: v_off_ini = 2326.486 uV, v_off_fin = 2332.796 uV 11:15:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.488 uVs 11:15:52 Integrated Voltage Measurement... 11:16:01 Voltage Offset Correction: v_off_ini = 2348.617 uV, v_off_fin = 2363.234 uV 11:16:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.900 uVs 11:16:03 I2X Average and RMS of Measurements VT = -119.230 +- 6.140 uVs I2X = 10.969 +- 0.565 uTm^2 11:16:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:16:11 Integrated Voltage Measurement... 11:16:20 Voltage Offset Correction: v_off_ini = 2348.183 uV, v_off_fin = 2334.215 uV 11:16:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.405 uVs 11:16:20 Integrated Voltage Measurement... 11:16:29 Voltage Offset Correction: v_off_ini = 2296.363 uV, v_off_fin = 2330.588 uV 11:16:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.119 uVs 11:16:29 Integrated Voltage Measurement... 11:16:38 Voltage Offset Correction: v_off_ini = 2332.412 uV, v_off_fin = 2336.925 uV 11:16:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.903 uVs 11:16:38 Integrated Voltage Measurement... 11:16:47 Voltage Offset Correction: v_off_ini = 2331.613 uV, v_off_fin = 2341.207 uV 11:16:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.333 uVs 11:16:47 Integrated Voltage Measurement... 11:16:56 Voltage Offset Correction: v_off_ini = 2312.305 uV, v_off_fin = 2316.647 uV 11:16:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -365.672 uVs 11:16:56 Integrated Voltage Measurement... 11:17:05 Voltage Offset Correction: v_off_ini = 2319.953 uV, v_off_fin = 2349.501 uV 11:17:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 395.314 uVs 11:17:08 I2Y Average and RMS of Measurements VT = -360.458 +- 14.943 uVs I2Y = -33.162 +- 1.375 uTm^2 11:17:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:17:23 Integrated Voltage Measurement... 11:17:32 Voltage Offset Correction: v_off_ini = 2358.835 uV, v_off_fin = 2315.164 uV 11:17:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.011 uVs 11:17:32 Integrated Voltage Measurement... 11:17:41 Voltage Offset Correction: v_off_ini = 2360.118 uV, v_off_fin = 2360.938 uV 11:17:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.590 uVs 11:17:41 Integrated Voltage Measurement... 11:17:50 Voltage Offset Correction: v_off_ini = 2353.494 uV, v_off_fin = 2332.993 uV 11:17:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.541 uVs 11:17:50 Integrated Voltage Measurement... 11:17:59 Voltage Offset Correction: v_off_ini = 2311.818 uV, v_off_fin = 2330.678 uV 11:17:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.980 uVs 11:17:59 Integrated Voltage Measurement... 11:18:08 Voltage Offset Correction: v_off_ini = 2334.321 uV, v_off_fin = 2351.685 uV 11:18:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.213 uVs 11:18:08 Integrated Voltage Measurement... 11:18:17 Voltage Offset Correction: v_off_ini = 2357.163 uV, v_off_fin = 2350.343 uV 11:18:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.622 uVs 11:18:21 I1X Average and RMS of Measurements VT = -120.159 +- 9.455 uVs I1X = 24.032 +- 1.891 uTm 11:18:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:18:28 Integrated Voltage Measurement... 11:18:37 Voltage Offset Correction: v_off_ini = 2337.999 uV, v_off_fin = 2348.515 uV 11:18:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -218.586 uVs 11:18:37 Integrated Voltage Measurement... 11:18:46 Voltage Offset Correction: v_off_ini = 2335.889 uV, v_off_fin = 2366.136 uV 11:18:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 232.303 uVs 11:18:46 Integrated Voltage Measurement... 11:18:55 Voltage Offset Correction: v_off_ini = 2348.929 uV, v_off_fin = 2314.990 uV 11:18:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.868 uVs 11:18:55 Integrated Voltage Measurement... 11:19:04 Voltage Offset Correction: v_off_ini = 2343.497 uV, v_off_fin = 2367.982 uV 11:19:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.240 uVs 11:19:04 Integrated Voltage Measurement... 11:19:13 Voltage Offset Correction: v_off_ini = 2336.654 uV, v_off_fin = 2320.903 uV 11:19:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.164 uVs 11:19:13 Integrated Voltage Measurement... 11:19:21 Voltage Offset Correction: v_off_ini = 2335.519 uV, v_off_fin = 2367.857 uV 11:19:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.024 uVs 11:19:26 I1Y Average and RMS of Measurements VT = -212.531 +- 9.140 uVs I1Y = -42.503 +- 1.829 uTm 11:19:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:19:33 Integrated Voltage Measurement... 11:19:42 Voltage Offset Correction: v_off_ini = 2331.193 uV, v_off_fin = 2340.493 uV 11:19:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -96.573 uVs 11:19:42 Integrated Voltage Measurement... 11:19:51 Voltage Offset Correction: v_off_ini = 2336.993 uV, v_off_fin = 2344.969 uV 11:19:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.120 uVs 11:19:51 Integrated Voltage Measurement... 11:20:00 Voltage Offset Correction: v_off_ini = 2348.588 uV, v_off_fin = 2345.607 uV 11:20:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -140.525 uVs 11:20:00 Integrated Voltage Measurement... 11:20:09 Voltage Offset Correction: v_off_ini = 2359.595 uV, v_off_fin = 2357.240 uV 11:20:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.853 uVs 11:20:09 Integrated Voltage Measurement... 11:20:18 Voltage Offset Correction: v_off_ini = 2349.607 uV, v_off_fin = 2347.182 uV 11:20:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -89.130 uVs 11:20:19 Integrated Voltage Measurement... 11:20:27 Voltage Offset Correction: v_off_ini = 2342.011 uV, v_off_fin = 2352.972 uV 11:20:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.195 uVs 11:20:30 I2X Average and RMS of Measurements VT = -103.566 +- 5.253 uVs I2X = 9.528 +- 0.484 uTm^2 11:20:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:20:38 Integrated Voltage Measurement... 11:20:47 Voltage Offset Correction: v_off_ini = 2312.103 uV, v_off_fin = 2315.038 uV 11:20:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.682 uVs 11:20:47 Integrated Voltage Measurement... 11:20:56 Voltage Offset Correction: v_off_ini = 2316.892 uV, v_off_fin = 2328.058 uV 11:20:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.838 uVs 11:20:56 Integrated Voltage Measurement... 11:21:05 Voltage Offset Correction: v_off_ini = 2306.783 uV, v_off_fin = 2313.110 uV 11:21:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -345.789 uVs 11:21:05 Integrated Voltage Measurement... 11:21:14 Voltage Offset Correction: v_off_ini = 2329.202 uV, v_off_fin = 2289.504 uV 11:21:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.138 uVs 11:21:14 Integrated Voltage Measurement... 11:21:23 Voltage Offset Correction: v_off_ini = 2312.476 uV, v_off_fin = 2309.866 uV 11:21:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.739 uVs 11:21:23 Integrated Voltage Measurement... 11:21:32 Voltage Offset Correction: v_off_ini = 2280.257 uV, v_off_fin = 2255.147 uV 11:21:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 405.343 uVs 11:21:34 I2Y Average and RMS of Measurements VT = -353.588 +- 12.113 uVs I2Y = -32.531 +- 1.114 uTm^2 11:21:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:21:49 Integrated Voltage Measurement... 11:21:58 Voltage Offset Correction: v_off_ini = 2290.900 uV, v_off_fin = 2281.148 uV 11:21:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.390 uVs 11:21:58 Integrated Voltage Measurement... 11:22:07 Voltage Offset Correction: v_off_ini = 2342.480 uV, v_off_fin = 2329.922 uV 11:22:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.803 uVs 11:22:07 Integrated Voltage Measurement... 11:22:16 Voltage Offset Correction: v_off_ini = 2320.204 uV, v_off_fin = 2309.539 uV 11:22:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.035 uVs 11:22:16 Integrated Voltage Measurement... 11:22:25 Voltage Offset Correction: v_off_ini = 2333.755 uV, v_off_fin = 2333.788 uV 11:22:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.807 uVs 11:22:25 Integrated Voltage Measurement... 11:22:34 Voltage Offset Correction: v_off_ini = 2318.137 uV, v_off_fin = 2306.249 uV 11:22:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.202 uVs 11:22:34 Integrated Voltage Measurement... 11:22:43 Voltage Offset Correction: v_off_ini = 2325.674 uV, v_off_fin = 2316.566 uV 11:22:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.741 uVs 11:22:47 I1X Average and RMS of Measurements VT = -87.496 +- 8.140 uVs I1X = 17.500 +- 1.628 uTm 11:22:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:54 Integrated Voltage Measurement... 11:23:03 Voltage Offset Correction: v_off_ini = 2316.102 uV, v_off_fin = 2324.401 uV 11:23:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.772 uVs 11:23:03 Integrated Voltage Measurement... 11:23:12 Voltage Offset Correction: v_off_ini = 2366.615 uV, v_off_fin = 2364.234 uV 11:23:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.033 uVs 11:23:12 Integrated Voltage Measurement... 11:23:21 Voltage Offset Correction: v_off_ini = 2364.292 uV, v_off_fin = 2346.573 uV 11:23:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.843 uVs 11:23:21 Integrated Voltage Measurement... 11:23:30 Voltage Offset Correction: v_off_ini = 2329.847 uV, v_off_fin = 2330.290 uV 11:23:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.227 uVs 11:23:30 Integrated Voltage Measurement... 11:23:39 Voltage Offset Correction: v_off_ini = 2327.713 uV, v_off_fin = 2323.121 uV 11:23:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.712 uVs 11:23:39 Integrated Voltage Measurement... 11:23:48 Voltage Offset Correction: v_off_ini = 2333.322 uV, v_off_fin = 2372.870 uV 11:23:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.943 uVs 11:23:52 I1Y Average and RMS of Measurements VT = -217.422 +- 5.044 uVs I1Y = -43.482 +- 1.009 uTm 11:23:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:24:00 Integrated Voltage Measurement... 11:24:09 Voltage Offset Correction: v_off_ini = 2340.192 uV, v_off_fin = 2305.846 uV 11:24:09 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -120.510 uVs 11:24:09 Integrated Voltage Measurement... 11:24:18 Voltage Offset Correction: v_off_ini = 2322.742 uV, v_off_fin = 2337.228 uV 11:24:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.198 uVs 11:24:18 Integrated Voltage Measurement... 11:24:27 Voltage Offset Correction: v_off_ini = 2315.779 uV, v_off_fin = 2318.605 uV 11:24:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.587 uVs 11:24:27 Integrated Voltage Measurement... 11:24:36 Voltage Offset Correction: v_off_ini = 2335.731 uV, v_off_fin = 2336.104 uV 11:24:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.499 uVs 11:24:36 Integrated Voltage Measurement... 11:24:45 Voltage Offset Correction: v_off_ini = 2341.220 uV, v_off_fin = 2358.998 uV 11:24:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.704 uVs 11:24:45 Integrated Voltage Measurement... 11:24:54 Voltage Offset Correction: v_off_ini = 2361.700 uV, v_off_fin = 2362.116 uV 11:24:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.287 uVs 11:24:57 I2X Average and RMS of Measurements VT = -108.798 +- 1.471 uVs I2X = 10.009 +- 0.135 uTm^2 11:25:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:25:04 Integrated Voltage Measurement... 11:25:13 Voltage Offset Correction: v_off_ini = 2370.531 uV, v_off_fin = 2357.841 uV 11:25:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -350.611 uVs 11:25:13 Integrated Voltage Measurement... 11:25:22 Voltage Offset Correction: v_off_ini = 2364.704 uV, v_off_fin = 2361.715 uV 11:25:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 340.887 uVs 11:25:22 Integrated Voltage Measurement... 11:25:31 Voltage Offset Correction: v_off_ini = 2369.413 uV, v_off_fin = 2373.682 uV 11:25:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.531 uVs 11:25:31 Integrated Voltage Measurement... 11:25:40 Voltage Offset Correction: v_off_ini = 2366.662 uV, v_off_fin = 2341.482 uV 11:25:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.746 uVs 11:25:40 Integrated Voltage Measurement... 11:25:49 Voltage Offset Correction: v_off_ini = 2385.763 uV, v_off_fin = 2367.739 uV 11:25:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.951 uVs 11:25:49 Integrated Voltage Measurement... 11:25:58 Voltage Offset Correction: v_off_ini = 2385.415 uV, v_off_fin = 2383.371 uV 11:25:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.512 uVs 11:26:01 I2Y Average and RMS of Measurements VT = -336.706 +- 10.023 uVs I2Y = -30.978 +- 0.923 uTm^2 11:26:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:26:16 Integrated Voltage Measurement... 11:26:25 Voltage Offset Correction: v_off_ini = 2381.836 uV, v_off_fin = 2375.853 uV 11:26:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -160.510 uVs 11:26:25 Integrated Voltage Measurement... 11:26:34 Voltage Offset Correction: v_off_ini = 2360.940 uV, v_off_fin = 2390.807 uV 11:26:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.585 uVs 11:26:34 Integrated Voltage Measurement... 11:26:43 Voltage Offset Correction: v_off_ini = 2373.839 uV, v_off_fin = 2371.900 uV 11:26:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.440 uVs 11:26:43 Integrated Voltage Measurement... 11:26:52 Voltage Offset Correction: v_off_ini = 2366.738 uV, v_off_fin = 2381.555 uV 11:26:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.193 uVs 11:26:52 Integrated Voltage Measurement... 11:27:01 Voltage Offset Correction: v_off_ini = 2361.607 uV, v_off_fin = 2378.679 uV 11:27:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.163 uVs 11:27:01 Integrated Voltage Measurement... 11:27:10 Voltage Offset Correction: v_off_ini = 2360.849 uV, v_off_fin = 2353.877 uV 11:27:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.945 uVs 11:27:14 I1X Average and RMS of Measurements VT = -122.640 +- 22.385 uVs I1X = 24.530 +- 4.479 uTm 11:27:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:27:21 Integrated Voltage Measurement... 11:27:30 Voltage Offset Correction: v_off_ini = 2366.437 uV, v_off_fin = 2350.481 uV 11:27:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -198.107 uVs 11:27:30 Integrated Voltage Measurement... 11:27:39 Voltage Offset Correction: v_off_ini = 2357.037 uV, v_off_fin = 2384.071 uV 11:27:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.419 uVs 11:27:39 Integrated Voltage Measurement... 11:27:48 Voltage Offset Correction: v_off_ini = 2348.906 uV, v_off_fin = 2325.038 uV 11:27:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.490 uVs 11:27:48 Integrated Voltage Measurement... 11:27:57 Voltage Offset Correction: v_off_ini = 2324.929 uV, v_off_fin = 2347.121 uV 11:27:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 215.486 uVs 11:27:57 Integrated Voltage Measurement... 11:28:06 Voltage Offset Correction: v_off_ini = 2355.923 uV, v_off_fin = 2353.024 uV 11:28:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -202.508 uVs 11:28:06 Integrated Voltage Measurement... 11:28:15 Voltage Offset Correction: v_off_ini = 2324.676 uV, v_off_fin = 2363.824 uV 11:28:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 228.595 uVs 11:28:19 I1Y Average and RMS of Measurements VT = -208.768 +- 6.634 uVs I1Y = -41.748 +- 1.323 uTm 11:28:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:28:27 Integrated Voltage Measurement... 11:28:36 Voltage Offset Correction: v_off_ini = 2323.888 uV, v_off_fin = 2357.923 uV 11:28:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.129 uVs 11:28:36 Integrated Voltage Measurement... 11:28:45 Voltage Offset Correction: v_off_ini = 2339.714 uV, v_off_fin = 2383.294 uV 11:28:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.727 uVs 11:28:45 Integrated Voltage Measurement... 11:28:54 Voltage Offset Correction: v_off_ini = 2393.731 uV, v_off_fin = 2354.548 uV 11:28:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.076 uVs 11:28:54 Integrated Voltage Measurement... 11:29:03 Voltage Offset Correction: v_off_ini = 2382.520 uV, v_off_fin = 2417.941 uV 11:29:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.899 uVs 11:29:03 Integrated Voltage Measurement... 11:29:12 Voltage Offset Correction: v_off_ini = 2393.752 uV, v_off_fin = 2382.499 uV 11:29:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.975 uVs 11:29:12 Integrated Voltage Measurement... 11:29:21 Voltage Offset Correction: v_off_ini = 2388.784 uV, v_off_fin = 2393.372 uV 11:29:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.941 uVs 11:29:23 I2X Average and RMS of Measurements VT = -125.625 +- 11.197 uVs I2X = 11.558 +- 1.030 uTm^2 11:29:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:29:31 Integrated Voltage Measurement... 11:29:40 Voltage Offset Correction: v_off_ini = 2386.492 uV, v_off_fin = 2368.428 uV 11:29:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.204 uVs 11:29:40 Integrated Voltage Measurement... 11:29:49 Voltage Offset Correction: v_off_ini = 2354.807 uV, v_off_fin = 2368.697 uV 11:29:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.530 uVs 11:29:49 Integrated Voltage Measurement... 11:29:58 Voltage Offset Correction: v_off_ini = 2373.655 uV, v_off_fin = 2388.355 uV 11:29:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.906 uVs 11:29:58 Integrated Voltage Measurement... 11:30:07 Voltage Offset Correction: v_off_ini = 2372.331 uV, v_off_fin = 2396.280 uV 11:30:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 317.393 uVs 11:30:07 Integrated Voltage Measurement... 11:30:16 Voltage Offset Correction: v_off_ini = 2375.224 uV, v_off_fin = 2378.874 uV 11:30:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.701 uVs 11:30:16 Integrated Voltage Measurement... 11:30:25 Voltage Offset Correction: v_off_ini = 2403.009 uV, v_off_fin = 2346.456 uV 11:30:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.660 uVs 11:30:28 I2Y Average and RMS of Measurements VT = -333.732 +- 13.485 uVs I2Y = -30.704 +- 1.240 uTm^2 11:30:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:30:43 Integrated Voltage Measurement... 11:30:52 Voltage Offset Correction: v_off_ini = 2399.294 uV, v_off_fin = 2375.816 uV 11:30:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -93.410 uVs 11:30:52 Integrated Voltage Measurement... 11:31:01 Voltage Offset Correction: v_off_ini = 2401.557 uV, v_off_fin = 2403.666 uV 11:31:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.859 uVs 11:31:01 Integrated Voltage Measurement... 11:31:10 Voltage Offset Correction: v_off_ini = 2403.865 uV, v_off_fin = 2386.871 uV 11:31:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.085 uVs 11:31:10 Integrated Voltage Measurement... 11:31:19 Voltage Offset Correction: v_off_ini = 2393.285 uV, v_off_fin = 2400.969 uV 11:31:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.834 uVs 11:31:19 Integrated Voltage Measurement... 11:31:28 Voltage Offset Correction: v_off_ini = 2393.300 uV, v_off_fin = 2417.110 uV 11:31:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.079 uVs 11:31:28 Integrated Voltage Measurement... 11:31:37 Voltage Offset Correction: v_off_ini = 2412.864 uV, v_off_fin = 2421.338 uV 11:31:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.119 uVs 11:31:41 I1X Average and RMS of Measurements VT = -109.398 +- 15.679 uVs I1X = 21.881 +- 3.135 uTm 11:31:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:48 Integrated Voltage Measurement... 11:31:57 Voltage Offset Correction: v_off_ini = 2422.654 uV, v_off_fin = 2390.480 uV 11:31:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -208.663 uVs 11:31:57 Integrated Voltage Measurement... 11:32:06 Voltage Offset Correction: v_off_ini = 2389.752 uV, v_off_fin = 2430.033 uV 11:32:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.308 uVs 11:32:06 Integrated Voltage Measurement... 11:32:15 Voltage Offset Correction: v_off_ini = 2428.873 uV, v_off_fin = 2400.196 uV 11:32:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -211.981 uVs 11:32:15 Integrated Voltage Measurement... 11:32:24 Voltage Offset Correction: v_off_ini = 2407.240 uV, v_off_fin = 2432.185 uV 11:32:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.005 uVs 11:32:24 Integrated Voltage Measurement... 11:32:33 Voltage Offset Correction: v_off_ini = 2386.605 uV, v_off_fin = 2393.247 uV 11:32:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.912 uVs 11:32:33 Integrated Voltage Measurement... 11:32:42 Voltage Offset Correction: v_off_ini = 2365.830 uV, v_off_fin = 2402.432 uV 11:32:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 221.243 uVs 11:32:46 I1Y Average and RMS of Measurements VT = -213.852 +- 3.083 uVs I1Y = -42.766 +- 0.618 uTm 11:32:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:32:53 Integrated Voltage Measurement... 11:33:02 Voltage Offset Correction: v_off_ini = 2374.391 uV, v_off_fin = 2368.077 uV 11:33:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.636 uVs 11:33:03 Integrated Voltage Measurement... 11:33:11 Voltage Offset Correction: v_off_ini = 2395.679 uV, v_off_fin = 2378.061 uV 11:33:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.491 uVs 11:33:12 Integrated Voltage Measurement... 11:33:21 Voltage Offset Correction: v_off_ini = 2362.444 uV, v_off_fin = 2369.029 uV 11:33:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.457 uVs 11:33:21 Integrated Voltage Measurement... 11:33:30 Voltage Offset Correction: v_off_ini = 2367.026 uV, v_off_fin = 2371.314 uV 11:33:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.278 uVs 11:33:30 Integrated Voltage Measurement... 11:33:39 Voltage Offset Correction: v_off_ini = 2372.327 uV, v_off_fin = 2351.151 uV 11:33:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.692 uVs 11:33:39 Integrated Voltage Measurement... 11:33:48 Voltage Offset Correction: v_off_ini = 2371.033 uV, v_off_fin = 2376.922 uV 11:33:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 94.483 uVs 11:33:50 I2X Average and RMS of Measurements VT = -113.673 +- 11.510 uVs I2X = 10.458 +- 1.059 uTm^2 11:33:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:33:58 Integrated Voltage Measurement... 11:34:07 Voltage Offset Correction: v_off_ini = 2330.791 uV, v_off_fin = 2362.575 uV 11:34:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.878 uVs 11:34:07 Integrated Voltage Measurement... 11:34:16 Voltage Offset Correction: v_off_ini = 2362.876 uV, v_off_fin = 2339.454 uV 11:34:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.845 uVs 11:34:16 Integrated Voltage Measurement... 11:34:25 Voltage Offset Correction: v_off_ini = 2347.122 uV, v_off_fin = 2340.411 uV 11:34:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.587 uVs 11:34:25 Integrated Voltage Measurement... 11:34:34 Voltage Offset Correction: v_off_ini = 2348.947 uV, v_off_fin = 2327.021 uV 11:34:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.930 uVs 11:34:34 Integrated Voltage Measurement... 11:34:43 Voltage Offset Correction: v_off_ini = 2337.178 uV, v_off_fin = 2338.283 uV 11:34:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.179 uVs 11:34:43 Integrated Voltage Measurement... 11:34:52 Voltage Offset Correction: v_off_ini = 2338.313 uV, v_off_fin = 2297.275 uV 11:34:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.019 uVs 11:34:54 I2Y Average and RMS of Measurements VT = -328.740 +- 7.047 uVs I2Y = -30.244 +- 0.648 uTm^2 11:35:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:35:09 Integrated Voltage Measurement... 11:35:18 Voltage Offset Correction: v_off_ini = 2370.720 uV, v_off_fin = 2339.885 uV 11:35:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -107.973 uVs 11:35:18 Integrated Voltage Measurement... 11:35:27 Voltage Offset Correction: v_off_ini = 2339.966 uV, v_off_fin = 2332.425 uV 11:35:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.053 uVs 11:35:27 Integrated Voltage Measurement... 11:35:36 Voltage Offset Correction: v_off_ini = 2340.592 uV, v_off_fin = 2341.519 uV 11:35:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.455 uVs 11:35:36 Integrated Voltage Measurement... 11:35:45 Voltage Offset Correction: v_off_ini = 2342.536 uV, v_off_fin = 2349.504 uV 11:35:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.172 uVs 11:35:45 Integrated Voltage Measurement... 11:35:54 Voltage Offset Correction: v_off_ini = 2335.013 uV, v_off_fin = 2332.854 uV 11:35:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.813 uVs 11:35:54 Integrated Voltage Measurement... 11:36:03 Voltage Offset Correction: v_off_ini = 2332.350 uV, v_off_fin = 2363.363 uV 11:36:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.064 uVs 11:36:08 I1X Average and RMS of Measurements VT = -106.255 +- 3.526 uVs I1X = 21.252 +- 0.705 uTm 11:36:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:14 Integrated Voltage Measurement... 11:36:23 Voltage Offset Correction: v_off_ini = 2378.121 uV, v_off_fin = 2357.820 uV 11:36:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.908 uVs 11:36:23 Integrated Voltage Measurement... 11:36:32 Voltage Offset Correction: v_off_ini = 2382.719 uV, v_off_fin = 2389.328 uV 11:36:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 218.681 uVs 11:36:32 Integrated Voltage Measurement... 11:36:41 Voltage Offset Correction: v_off_ini = 2374.413 uV, v_off_fin = 2336.408 uV 11:36:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -197.333 uVs 11:36:41 Integrated Voltage Measurement... 11:36:50 Voltage Offset Correction: v_off_ini = 2377.614 uV, v_off_fin = 2371.801 uV 11:36:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.598 uVs 11:36:50 Integrated Voltage Measurement... 11:36:59 Voltage Offset Correction: v_off_ini = 2355.126 uV, v_off_fin = 2339.703 uV 11:36:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.443 uVs 11:36:59 Integrated Voltage Measurement... 11:37:08 Voltage Offset Correction: v_off_ini = 2357.755 uV, v_off_fin = 2352.593 uV 11:37:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.584 uVs 11:37:13 I1Y Average and RMS of Measurements VT = -199.258 +- 9.013 uVs I1Y = -39.847 +- 1.801 uTm 11:37:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:37:20 Integrated Voltage Measurement... 11:37:29 Voltage Offset Correction: v_off_ini = 2324.529 uV, v_off_fin = 2370.464 uV 11:37:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.825 uVs 11:37:29 Integrated Voltage Measurement... 11:37:38 Voltage Offset Correction: v_off_ini = 2401.990 uV, v_off_fin = 2407.526 uV 11:37:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.036 uVs 11:37:38 Integrated Voltage Measurement... 11:37:47 Voltage Offset Correction: v_off_ini = 2386.820 uV, v_off_fin = 2363.032 uV 11:37:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.980 uVs 11:37:47 Integrated Voltage Measurement... 11:37:56 Voltage Offset Correction: v_off_ini = 2398.447 uV, v_off_fin = 2407.502 uV 11:37:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.820 uVs 11:37:56 Integrated Voltage Measurement... 11:38:05 Voltage Offset Correction: v_off_ini = 2371.423 uV, v_off_fin = 2325.788 uV 11:38:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.307 uVs 11:38:05 Integrated Voltage Measurement... 11:38:14 Voltage Offset Correction: v_off_ini = 2409.757 uV, v_off_fin = 2405.696 uV 11:38:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.718 uVs 11:38:17 I2X Average and RMS of Measurements VT = -107.448 +- 7.315 uVs I2X = 9.885 +- 0.673 uTm^2 11:38:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:38:25 Integrated Voltage Measurement... 11:38:34 Voltage Offset Correction: v_off_ini = 2402.895 uV, v_off_fin = 2393.917 uV 11:38:34 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = -347.076 uVs 11:38:34 Integrated Voltage Measurement... 11:38:43 Voltage Offset Correction: v_off_ini = 2384.685 uV, v_off_fin = 2398.166 uV 11:38:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 307.720 uVs 11:38:43 Integrated Voltage Measurement... 11:38:52 Voltage Offset Correction: v_off_ini = 2409.616 uV, v_off_fin = 2405.900 uV 11:38:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.134 uVs 11:38:52 Integrated Voltage Measurement... 11:39:01 Voltage Offset Correction: v_off_ini = 2406.072 uV, v_off_fin = 2413.761 uV 11:39:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 338.370 uVs 11:39:01 Integrated Voltage Measurement... 11:39:10 Voltage Offset Correction: v_off_ini = 2418.711 uV, v_off_fin = 2416.403 uV 11:39:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.593 uVs 11:39:10 Integrated Voltage Measurement... 11:39:19 Voltage Offset Correction: v_off_ini = 2414.839 uV, v_off_fin = 2387.010 uV 11:39:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.736 uVs 11:39:21 I2Y Average and RMS of Measurements VT = -304.938 +- 27.199 uVs I2Y = -28.056 +- 2.504 uTm^2 11:39:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:37 Integrated Voltage Measurement... 11:39:46 Voltage Offset Correction: v_off_ini = 2420.385 uV, v_off_fin = 2384.523 uV 11:39:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -101.034 uVs 11:39:46 Integrated Voltage Measurement... 11:39:55 Voltage Offset Correction: v_off_ini = 2395.459 uV, v_off_fin = 2408.941 uV 11:39:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.443 uVs 11:39:55 Integrated Voltage Measurement... 11:40:04 Voltage Offset Correction: v_off_ini = 2391.875 uV, v_off_fin = 2377.817 uV 11:40:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.125 uVs 11:40:04 Integrated Voltage Measurement... 11:40:13 Voltage Offset Correction: v_off_ini = 2398.600 uV, v_off_fin = 2391.124 uV 11:40:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.954 uVs 11:40:13 Integrated Voltage Measurement... 11:40:22 Voltage Offset Correction: v_off_ini = 2390.245 uV, v_off_fin = 2425.965 uV 11:40:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.762 uVs 11:40:22 Integrated Voltage Measurement... 11:40:31 Voltage Offset Correction: v_off_ini = 2407.911 uV, v_off_fin = 2392.797 uV 11:40:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.739 uVs 11:40:36 I1X Average and RMS of Measurements VT = -95.843 +- 16.691 uVs I1X = 19.170 +- 3.338 uTm 11:40:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:40:42 Integrated Voltage Measurement... 11:40:51 Voltage Offset Correction: v_off_ini = 2390.988 uV, v_off_fin = 2400.425 uV 11:40:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.828 uVs 11:40:51 Integrated Voltage Measurement... 11:41:00 Voltage Offset Correction: v_off_ini = 2397.566 uV, v_off_fin = 2405.819 uV 11:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 198.400 uVs 11:41:00 Integrated Voltage Measurement... 11:41:09 Voltage Offset Correction: v_off_ini = 2427.769 uV, v_off_fin = 2411.539 uV 11:41:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -206.420 uVs 11:41:09 Integrated Voltage Measurement... 11:41:18 Voltage Offset Correction: v_off_ini = 2401.086 uV, v_off_fin = 2439.203 uV 11:41:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 227.607 uVs 11:41:18 Integrated Voltage Measurement... 11:41:27 Voltage Offset Correction: v_off_ini = 2412.045 uV, v_off_fin = 2403.185 uV 11:41:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -200.154 uVs 11:41:27 Integrated Voltage Measurement... 11:41:36 Voltage Offset Correction: v_off_ini = 2420.583 uV, v_off_fin = 2423.919 uV 11:41:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 194.702 uVs 11:41:40 I1Y Average and RMS of Measurements VT = -201.185 +- 11.696 uVs I1Y = -40.230 +- 2.337 uTm 11:41:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:41:48 Integrated Voltage Measurement... 11:41:57 Voltage Offset Correction: v_off_ini = 2389.954 uV, v_off_fin = 2389.409 uV 11:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.497 uVs 11:41:57 Integrated Voltage Measurement... 11:42:06 Voltage Offset Correction: v_off_ini = 2397.441 uV, v_off_fin = 2399.318 uV 11:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.063 uVs 11:42:06 Integrated Voltage Measurement... 11:42:15 Voltage Offset Correction: v_off_ini = 2414.984 uV, v_off_fin = 2398.948 uV 11:42:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.043 uVs 11:42:15 Integrated Voltage Measurement... 11:42:24 Voltage Offset Correction: v_off_ini = 2408.289 uV, v_off_fin = 2401.692 uV 11:42:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.855 uVs 11:42:24 Integrated Voltage Measurement... 11:42:33 Voltage Offset Correction: v_off_ini = 2407.856 uV, v_off_fin = 2405.704 uV 11:42:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.430 uVs 11:42:33 Integrated Voltage Measurement... 11:42:42 Voltage Offset Correction: v_off_ini = 2402.219 uV, v_off_fin = 2418.346 uV 11:42:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.119 uVs 11:42:45 I2X Average and RMS of Measurements VT = -98.335 +- 6.887 uVs I2X = 9.047 +- 0.634 uTm^2 11:42:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:42:52 Integrated Voltage Measurement... 11:43:01 Voltage Offset Correction: v_off_ini = 2401.608 uV, v_off_fin = 2395.863 uV 11:43:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -300.713 uVs 11:43:01 Integrated Voltage Measurement... 11:43:10 Voltage Offset Correction: v_off_ini = 2400.860 uV, v_off_fin = 2399.630 uV 11:43:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 341.494 uVs 11:43:10 Integrated Voltage Measurement... 11:43:19 Voltage Offset Correction: v_off_ini = 2401.708 uV, v_off_fin = 2401.158 uV 11:43:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.422 uVs 11:43:19 Integrated Voltage Measurement... 11:43:28 Voltage Offset Correction: v_off_ini = 2407.962 uV, v_off_fin = 2406.009 uV 11:43:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.041 uVs 11:43:29 Integrated Voltage Measurement... 11:43:37 Voltage Offset Correction: v_off_ini = 2407.537 uV, v_off_fin = 2418.283 uV 11:43:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.168 uVs 11:43:38 Integrated Voltage Measurement... 11:43:47 Voltage Offset Correction: v_off_ini = 2393.402 uV, v_off_fin = 2393.144 uV 11:43:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.148 uVs 11:43:49 I2Y Average and RMS of Measurements VT = -318.164 +- 9.987 uVs I2Y = -29.272 +- 0.919 uTm^2 11:44:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:44:05 Integrated Voltage Measurement... 11:44:14 Voltage Offset Correction: v_off_ini = 2419.673 uV, v_off_fin = 2381.591 uV 11:44:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.140 uVs 11:44:14 Integrated Voltage Measurement... 11:44:23 Voltage Offset Correction: v_off_ini = 2401.165 uV, v_off_fin = 2399.537 uV 11:44:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.641 uVs 11:44:23 Integrated Voltage Measurement... 11:44:32 Voltage Offset Correction: v_off_ini = 2384.805 uV, v_off_fin = 2392.505 uV 11:44:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.451 uVs 11:44:32 Integrated Voltage Measurement... 11:44:41 Voltage Offset Correction: v_off_ini = 2391.195 uV, v_off_fin = 2390.939 uV 11:44:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.657 uVs 11:44:41 Integrated Voltage Measurement... 11:44:50 Voltage Offset Correction: v_off_ini = 2386.741 uV, v_off_fin = 2383.476 uV 11:44:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.577 uVs 11:44:50 Integrated Voltage Measurement... 11:44:59 Voltage Offset Correction: v_off_ini = 2421.154 uV, v_off_fin = 2397.231 uV 11:44:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.899 uVs 11:45:03 I1X Average and RMS of Measurements VT = -82.561 +- 11.237 uVs I1X = 16.513 +- 2.248 uTm 11:45:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:10 Integrated Voltage Measurement... 11:45:19 Voltage Offset Correction: v_off_ini = 2394.250 uV, v_off_fin = 2399.238 uV 11:45:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.210 uVs 11:45:19 Integrated Voltage Measurement... 11:45:28 Voltage Offset Correction: v_off_ini = 2389.682 uV, v_off_fin = 2414.815 uV 11:45:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 185.933 uVs 11:45:28 Integrated Voltage Measurement... 11:45:37 Voltage Offset Correction: v_off_ini = 2392.130 uV, v_off_fin = 2376.607 uV 11:45:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -195.749 uVs 11:45:37 Integrated Voltage Measurement... 11:45:46 Voltage Offset Correction: v_off_ini = 2379.454 uV, v_off_fin = 2383.227 uV 11:45:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 209.427 uVs 11:45:46 Integrated Voltage Measurement... 11:45:55 Voltage Offset Correction: v_off_ini = 2387.533 uV, v_off_fin = 2390.628 uV 11:45:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.392 uVs 11:45:55 Integrated Voltage Measurement... 11:46:04 Voltage Offset Correction: v_off_ini = 2393.932 uV, v_off_fin = 2420.015 uV 11:46:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 190.407 uVs 11:46:08 I1Y Average and RMS of Measurements VT = -193.186 +- 7.061 uVs I1Y = -38.631 +- 1.410 uTm 11:46:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:46:16 Integrated Voltage Measurement... 11:46:25 Voltage Offset Correction: v_off_ini = 2365.862 uV, v_off_fin = 2368.620 uV 11:46:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.828 uVs 11:46:25 Integrated Voltage Measurement... 11:46:34 Voltage Offset Correction: v_off_ini = 2368.384 uV, v_off_fin = 2371.978 uV 11:46:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.261 uVs 11:46:34 Integrated Voltage Measurement... 11:46:43 Voltage Offset Correction: v_off_ini = 2359.994 uV, v_off_fin = 2367.130 uV 11:46:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.921 uVs 11:46:43 Integrated Voltage Measurement... 11:46:52 Voltage Offset Correction: v_off_ini = 2359.613 uV, v_off_fin = 2350.711 uV 11:46:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.001 uVs 11:46:52 Integrated Voltage Measurement... 11:47:01 Voltage Offset Correction: v_off_ini = 2375.883 uV, v_off_fin = 2356.408 uV 11:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.481 uVs 11:47:01 Integrated Voltage Measurement... 11:47:10 Voltage Offset Correction: v_off_ini = 2357.900 uV, v_off_fin = 2353.502 uV 11:47:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.879 uVs 11:47:12 I2X Average and RMS of Measurements VT = -79.395 +- 3.620 uVs I2X = 7.305 +- 0.333 uTm^2 11:47:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:20 Integrated Voltage Measurement... 11:47:29 Voltage Offset Correction: v_off_ini = 2321.861 uV, v_off_fin = 2332.254 uV 11:47:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -311.866 uVs 11:47:29 Integrated Voltage Measurement... 11:47:38 Voltage Offset Correction: v_off_ini = 2331.859 uV, v_off_fin = 2330.008 uV 11:47:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.114 uVs 11:47:38 Integrated Voltage Measurement... 11:47:47 Voltage Offset Correction: v_off_ini = 2355.342 uV, v_off_fin = 2353.480 uV 11:47:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.156 uVs 11:47:47 Integrated Voltage Measurement... 11:47:56 Voltage Offset Correction: v_off_ini = 2344.846 uV, v_off_fin = 2344.873 uV 11:47:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.211 uVs 11:47:56 Integrated Voltage Measurement... 11:48:05 Voltage Offset Correction: v_off_ini = 2336.175 uV, v_off_fin = 2325.329 uV 11:48:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.556 uVs 11:48:05 Integrated Voltage Measurement... 11:48:14 Voltage Offset Correction: v_off_ini = 2346.118 uV, v_off_fin = 2328.435 uV 11:48:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.075 uVs 11:48:17 I2Y Average and RMS of Measurements VT = -305.663 +- 3.216 uVs I2Y = -28.121 +- 0.295 uTm^2 11:48:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:35 Integrated Voltage Measurement... 11:48:44 Voltage Offset Correction: v_off_ini = 2359.286 uV, v_off_fin = 2367.496 uV 11:48:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.709 uVs 11:48:44 Integrated Voltage Measurement... 11:48:53 Voltage Offset Correction: v_off_ini = 2358.434 uV, v_off_fin = 2358.767 uV 11:48:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.347 uVs 11:48:53 Integrated Voltage Measurement... 11:49:02 Voltage Offset Correction: v_off_ini = 2364.349 uV, v_off_fin = 2365.157 uV 11:49:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.425 uVs 11:49:02 Integrated Voltage Measurement... 11:49:11 Voltage Offset Correction: v_off_ini = 2367.883 uV, v_off_fin = 2369.372 uV 11:49:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.518 uVs 11:49:11 Integrated Voltage Measurement... 11:49:20 Voltage Offset Correction: v_off_ini = 2374.442 uV, v_off_fin = 2362.308 uV 11:49:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.153 uVs 11:49:20 Integrated Voltage Measurement... 11:49:29 Voltage Offset Correction: v_off_ini = 2343.179 uV, v_off_fin = 2357.506 uV 11:49:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.364 uVs 11:49:33 I1X Average and RMS of Measurements VT = -69.253 +- 11.583 uVs I1X = 13.851 +- 2.317 uTm 11:49:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:49:40 Integrated Voltage Measurement... 11:49:49 Voltage Offset Correction: v_off_ini = 2347.195 uV, v_off_fin = 2345.586 uV 11:49:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.834 uVs 11:49:49 Integrated Voltage Measurement... 11:49:58 Voltage Offset Correction: v_off_ini = 2345.869 uV, v_off_fin = 2360.528 uV 11:49:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.887 uVs 11:49:58 Integrated Voltage Measurement... 11:50:07 Voltage Offset Correction: v_off_ini = 2354.480 uV, v_off_fin = 2337.449 uV 11:50:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.173 uVs 11:50:07 Integrated Voltage Measurement... 11:50:16 Voltage Offset Correction: v_off_ini = 2347.567 uV, v_off_fin = 2344.293 uV 11:50:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.780 uVs 11:50:16 Integrated Voltage Measurement... 11:50:25 Voltage Offset Correction: v_off_ini = 2333.413 uV, v_off_fin = 2296.658 uV 11:50:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.557 uVs 11:50:25 Integrated Voltage Measurement... 11:50:34 Voltage Offset Correction: v_off_ini = 2344.652 uV, v_off_fin = 2356.209 uV 11:50:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.626 uVs 11:50:38 I1Y Average and RMS of Measurements VT = -192.309 +- 6.251 uVs I1Y = -38.461 +- 1.250 uTm 11:50:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:50:46 Integrated Voltage Measurement... 11:50:55 Voltage Offset Correction: v_off_ini = 2319.582 uV, v_off_fin = 2309.483 uV 11:50:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.730 uVs 11:50:55 Integrated Voltage Measurement... 11:51:04 Voltage Offset Correction: v_off_ini = 2365.645 uV, v_off_fin = 2377.419 uV 11:51:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.086 uVs 11:51:04 Integrated Voltage Measurement... 11:51:13 Voltage Offset Correction: v_off_ini = 2351.323 uV, v_off_fin = 2344.084 uV 11:51:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.123 uVs 11:51:13 Integrated Voltage Measurement... 11:51:22 Voltage Offset Correction: v_off_ini = 2334.853 uV, v_off_fin = 2360.174 uV 11:51:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.738 uVs 11:51:22 Integrated Voltage Measurement... 11:51:31 Voltage Offset Correction: v_off_ini = 2344.602 uV, v_off_fin = 2333.813 uV 11:51:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -78.085 uVs 11:51:31 Integrated Voltage Measurement... 11:51:40 Voltage Offset Correction: v_off_ini = 2325.491 uV, v_off_fin = 2358.426 uV 11:51:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.734 uVs 11:51:42 I2X Average and RMS of Measurements VT = -78.083 +- 6.900 uVs I2X = 7.184 +- 0.635 uTm^2 11:51:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:51:50 Integrated Voltage Measurement... 11:51:59 Voltage Offset Correction: v_off_ini = 2322.910 uV, v_off_fin = 2318.719 uV 11:51:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.015 uVs 11:51:59 Integrated Voltage Measurement... 11:52:08 Voltage Offset Correction: v_off_ini = 2337.323 uV, v_off_fin = 2330.301 uV 11:52:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.095 uVs 11:52:08 Integrated Voltage Measurement... 11:52:17 Voltage Offset Correction: v_off_ini = 2341.220 uV, v_off_fin = 2318.456 uV 11:52:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.092 uVs 11:52:17 Integrated Voltage Measurement... 11:52:26 Voltage Offset Correction: v_off_ini = 2331.095 uV, v_off_fin = 2312.606 uV 11:52:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.045 uVs 11:52:26 Integrated Voltage Measurement... 11:52:35 Voltage Offset Correction: v_off_ini = 2314.109 uV, v_off_fin = 2312.022 uV 11:52:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.553 uVs 11:52:35 Integrated Voltage Measurement... 11:52:44 Voltage Offset Correction: v_off_ini = 2319.634 uV, v_off_fin = 2324.682 uV 11:52:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.288 uVs 11:52:46 I2Y Average and RMS of Measurements VT = -272.848 +- 3.701 uVs I2Y = -25.102 +- 0.340 uTm^2 11:53:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:53:05 Integrated Voltage Measurement... 11:53:14 Voltage Offset Correction: v_off_ini = 2349.142 uV, v_off_fin = 2346.577 uV 11:53:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.623 uVs 11:53:14 Integrated Voltage Measurement... 11:53:23 Voltage Offset Correction: v_off_ini = 2311.726 uV, v_off_fin = 2326.851 uV 11:53:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.725 uVs 11:53:23 Integrated Voltage Measurement... 11:53:32 Voltage Offset Correction: v_off_ini = 2334.335 uV, v_off_fin = 2339.464 uV 11:53:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.899 uVs 11:53:32 Integrated Voltage Measurement... 11:53:41 Voltage Offset Correction: v_off_ini = 2340.660 uV, v_off_fin = 2317.490 uV 11:53:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.897 uVs 11:53:41 Integrated Voltage Measurement... 11:53:50 Voltage Offset Correction: v_off_ini = 2320.966 uV, v_off_fin = 2323.488 uV 11:53:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.066 uVs 11:53:50 Integrated Voltage Measurement... 11:53:59 Voltage Offset Correction: v_off_ini = 2336.622 uV, v_off_fin = 2355.579 uV 11:53:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.532 uVs 11:54:03 I1X Average and RMS of Measurements VT = -75.624 +- 2.326 uVs I1X = 15.125 +- 0.465 uTm 11:54:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:54:10 Integrated Voltage Measurement... 11:54:19 Voltage Offset Correction: v_off_ini = 2332.302 uV, v_off_fin = 2338.171 uV 11:54:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.143 uVs 11:54:19 Integrated Voltage Measurement... 11:54:28 Voltage Offset Correction: v_off_ini = 2310.972 uV, v_off_fin = 2327.169 uV 11:54:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.209 uVs 11:54:28 Integrated Voltage Measurement... 11:54:37 Voltage Offset Correction: v_off_ini = 2318.458 uV, v_off_fin = 2329.572 uV 11:54:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.280 uVs 11:54:37 Integrated Voltage Measurement... 11:54:46 Voltage Offset Correction: v_off_ini = 2324.708 uV, v_off_fin = 2350.315 uV 11:54:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.669 uVs 11:54:46 Integrated Voltage Measurement... 11:54:55 Voltage Offset Correction: v_off_ini = 2344.456 uV, v_off_fin = 2314.087 uV 11:54:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.314 uVs 11:54:55 Integrated Voltage Measurement... 11:55:04 Voltage Offset Correction: v_off_ini = 2315.767 uV, v_off_fin = 2374.396 uV 11:55:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.293 uVs 11:55:08 I1Y Average and RMS of Measurements VT = -190.652 +- 7.551 uVs I1Y = -38.127 +- 1.511 uTm 11:55:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:55:16 Integrated Voltage Measurement... 11:55:24 Voltage Offset Correction: v_off_ini = 2323.246 uV, v_off_fin = 2338.277 uV 11:55:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 5.995 uVs 11:55:25 Integrated Voltage Measurement... 11:55:34 Voltage Offset Correction: v_off_ini = 2333.576 uV, v_off_fin = 2339.415 uV 11:55:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.959 uVs 11:55:34 Integrated Voltage Measurement... 11:55:43 Voltage Offset Correction: v_off_ini = 2326.219 uV, v_off_fin = 2321.172 uV 11:55:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.798 uVs 11:55:43 Integrated Voltage Measurement... 11:55:52 Voltage Offset Correction: v_off_ini = 2317.929 uV, v_off_fin = 2320.400 uV 11:55:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.637 uVs 11:55:52 Integrated Voltage Measurement... 11:56:01 Voltage Offset Correction: v_off_ini = 2325.859 uV, v_off_fin = 2321.967 uV 11:56:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.248 uVs 11:56:01 Integrated Voltage Measurement... 11:56:10 Voltage Offset Correction: v_off_ini = 2327.043 uV, v_off_fin = 2316.408 uV 11:56:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.696 uVs 11:56:12 I2X Average and RMS of Measurements VT = -47.224 +- 25.274 uVs I2X = 4.345 +- 2.325 uTm^2 11:56:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:56:20 Integrated Voltage Measurement... 11:56:29 Voltage Offset Correction: v_off_ini = 2310.405 uV, v_off_fin = 2312.959 uV 11:56:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.634 uVs 11:56:29 Integrated Voltage Measurement... 11:56:38 Voltage Offset Correction: v_off_ini = 2309.746 uV, v_off_fin = 2314.262 uV 11:56:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.921 uVs 11:56:38 Integrated Voltage Measurement... 11:56:47 Voltage Offset Correction: v_off_ini = 2299.826 uV, v_off_fin = 2285.558 uV 11:56:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.379 uVs 11:56:47 Integrated Voltage Measurement... 11:56:56 Voltage Offset Correction: v_off_ini = 2326.235 uV, v_off_fin = 2323.689 uV 11:56:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.041 uVs 11:56:56 Integrated Voltage Measurement... 11:57:05 Voltage Offset Correction: v_off_ini = 2343.364 uV, v_off_fin = 2331.966 uV 11:57:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.687 uVs 11:57:05 Integrated Voltage Measurement... 11:57:14 Voltage Offset Correction: v_off_ini = 2338.183 uV, v_off_fin = 2344.158 uV 11:57:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.919 uVs 11:57:16 I2Y Average and RMS of Measurements VT = -285.597 +- 2.813 uVs I2Y = -26.275 +- 0.259 uTm^2 11:57:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:57:35 Integrated Voltage Measurement... 11:57:44 Voltage Offset Correction: v_off_ini = 2375.536 uV, v_off_fin = 2359.129 uV 11:57:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.118 uVs 11:57:44 Integrated Voltage Measurement... 11:57:53 Voltage Offset Correction: v_off_ini = 2368.917 uV, v_off_fin = 2363.702 uV 11:57:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.587 uVs 11:57:53 Integrated Voltage Measurement... 11:58:02 Voltage Offset Correction: v_off_ini = 2344.024 uV, v_off_fin = 2339.050 uV 11:58:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.483 uVs 11:58:02 Integrated Voltage Measurement... 11:58:11 Voltage Offset Correction: v_off_ini = 2357.113 uV, v_off_fin = 2382.310 uV 11:58:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.487 uVs 11:58:11 Integrated Voltage Measurement... 11:58:20 Voltage Offset Correction: v_off_ini = 2400.353 uV, v_off_fin = 2394.121 uV 11:58:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.335 uVs 11:58:20 Integrated Voltage Measurement... 11:58:29 Voltage Offset Correction: v_off_ini = 2397.126 uV, v_off_fin = 2386.041 uV 11:58:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.019 uVs 11:58:33 I1X Average and RMS of Measurements VT = -64.338 +- 13.158 uVs I1X = 12.868 +- 2.632 uTm 11:58:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:58:40 Integrated Voltage Measurement... 11:58:49 Voltage Offset Correction: v_off_ini = 2347.292 uV, v_off_fin = 2370.913 uV 11:58:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.315 uVs 11:58:49 Integrated Voltage Measurement... 11:58:58 Voltage Offset Correction: v_off_ini = 2380.969 uV, v_off_fin = 2401.723 uV 11:58:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 179.571 uVs 11:58:58 Integrated Voltage Measurement... 11:59:07 Voltage Offset Correction: v_off_ini = 2385.208 uV, v_off_fin = 2375.764 uV 11:59:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -241.573 uVs 11:59:07 Integrated Voltage Measurement... 11:59:16 Voltage Offset Correction: v_off_ini = 2370.218 uV, v_off_fin = 2394.534 uV 11:59:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.239 uVs 11:59:16 Integrated Voltage Measurement... 11:59:25 Voltage Offset Correction: v_off_ini = 2381.066 uV, v_off_fin = 2388.346 uV 11:59:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.238 uVs 11:59:25 Integrated Voltage Measurement... 11:59:34 Voltage Offset Correction: v_off_ini = 2370.948 uV, v_off_fin = 2391.905 uV 11:59:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.074 uVs 11:59:38 I1Y Average and RMS of Measurements VT = -191.168 +- 12.457 uVs I1Y = -38.229 +- 2.490 uTm 11:59:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:59:46 Integrated Voltage Measurement... 11:59:55 Voltage Offset Correction: v_off_ini = 2372.198 uV, v_off_fin = 2350.784 uV 11:59:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -13.630 uVs 11:59:55 Integrated Voltage Measurement... 12:00:04 Voltage Offset Correction: v_off_ini = 2413.602 uV, v_off_fin = 2418.422 uV 12:00:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.000 uVs 12:00:04 Integrated Voltage Measurement... 12:00:13 Voltage Offset Correction: v_off_ini = 2408.199 uV, v_off_fin = 2399.631 uV 12:00:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.208 uVs 12:00:13 Integrated Voltage Measurement... 12:00:22 Voltage Offset Correction: v_off_ini = 2406.703 uV, v_off_fin = 2446.044 uV 12:00:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.853 uVs 12:00:22 Integrated Voltage Measurement... 12:00:31 Voltage Offset Correction: v_off_ini = 2382.265 uV, v_off_fin = 2394.028 uV 12:00:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.365 uVs 12:00:31 Integrated Voltage Measurement... 12:00:40 Voltage Offset Correction: v_off_ini = 2404.989 uV, v_off_fin = 2398.528 uV 12:00:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.835 uVs 12:00:42 I2X Average and RMS of Measurements VT = -49.815 +- 10.393 uVs I2X = 4.583 +- 0.956 uTm^2 12:00:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:00:50 Integrated Voltage Measurement... 12:00:59 Voltage Offset Correction: v_off_ini = 2394.875 uV, v_off_fin = 2363.849 uV 12:00:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.394 uVs 12:00:59 Integrated Voltage Measurement... 12:01:08 Voltage Offset Correction: v_off_ini = 2442.722 uV, v_off_fin = 2431.315 uV 12:01:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.403 uVs 12:01:08 Integrated Voltage Measurement... 12:01:17 Voltage Offset Correction: v_off_ini = 2433.419 uV, v_off_fin = 2417.764 uV 12:01:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.542 uVs 12:01:17 Integrated Voltage Measurement... 12:01:26 Voltage Offset Correction: v_off_ini = 2405.483 uV, v_off_fin = 2411.950 uV 12:01:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.475 uVs 12:01:26 Integrated Voltage Measurement... 12:01:35 Voltage Offset Correction: v_off_ini = 2390.166 uV, v_off_fin = 2413.697 uV 12:01:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.137 uVs 12:01:35 Integrated Voltage Measurement... 12:01:44 Voltage Offset Correction: v_off_ini = 2385.702 uV, v_off_fin = 2413.050 uV 12:01:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.131 uVs 12:01:46 I2Y Average and RMS of Measurements VT = -245.514 +- 5.720 uVs I2Y = -22.587 +- 0.526 uTm^2 12:02:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:02:05 Integrated Voltage Measurement... 12:02:14 Voltage Offset Correction: v_off_ini = 2398.147 uV, v_off_fin = 2382.914 uV 12:02:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -45.049 uVs 12:02:14 Integrated Voltage Measurement... 12:02:23 Voltage Offset Correction: v_off_ini = 2410.978 uV, v_off_fin = 2394.624 uV 12:02:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.596 uVs 12:02:23 Integrated Voltage Measurement... 12:02:32 Voltage Offset Correction: v_off_ini = 2410.654 uV, v_off_fin = 2411.661 uV 12:02:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.187 uVs 12:02:32 Integrated Voltage Measurement... 12:02:41 Voltage Offset Correction: v_off_ini = 2390.400 uV, v_off_fin = 2414.458 uV 12:02:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.602 uVs 12:02:41 Integrated Voltage Measurement... 12:02:50 Voltage Offset Correction: v_off_ini = 2410.573 uV, v_off_fin = 2439.109 uV 12:02:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.974 uVs 12:02:50 Integrated Voltage Measurement... 12:02:59 Voltage Offset Correction: v_off_ini = 2432.032 uV, v_off_fin = 2426.199 uV 12:02:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 23.736 uVs 12:03:03 I1X Average and RMS of Measurements VT = -49.691 +- 12.000 uVs I1X = 9.939 +- 2.400 uTm 12:03:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:03:10 Integrated Voltage Measurement... 12:03:19 Voltage Offset Correction: v_off_ini = 2413.403 uV, v_off_fin = 2397.787 uV 12:03:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.542 uVs 12:03:19 Integrated Voltage Measurement... 12:03:28 Voltage Offset Correction: v_off_ini = 2438.776 uV, v_off_fin = 2438.360 uV 12:03:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 191.594 uVs 12:03:28 Integrated Voltage Measurement... 12:03:37 Voltage Offset Correction: v_off_ini = 2435.911 uV, v_off_fin = 2410.128 uV 12:03:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.330 uVs 12:03:37 Integrated Voltage Measurement... 12:03:46 Voltage Offset Correction: v_off_ini = 2439.186 uV, v_off_fin = 2440.910 uV 12:03:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 159.656 uVs 12:03:46 Integrated Voltage Measurement... 12:03:55 Voltage Offset Correction: v_off_ini = 2427.344 uV, v_off_fin = 2413.879 uV 12:03:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.154 uVs 12:03:55 Integrated Voltage Measurement... 12:04:04 Voltage Offset Correction: v_off_ini = 2427.674 uV, v_off_fin = 2464.686 uV 12:04:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.441 uVs 12:04:08 I1Y Average and RMS of Measurements VT = -186.786 +- 5.695 uVs I1Y = -37.357 +- 1.141 uTm 12:04:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:04:16 Integrated Voltage Measurement... 12:04:25 Voltage Offset Correction: v_off_ini = 2426.496 uV, v_off_fin = 2428.863 uV 12:04:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -22.313 uVs 12:04:25 Integrated Voltage Measurement... 12:04:34 Voltage Offset Correction: v_off_ini = 2432.553 uV, v_off_fin = 2430.073 uV 12:04:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 37.853 uVs 12:04:34 Integrated Voltage Measurement... 12:04:43 Voltage Offset Correction: v_off_ini = 2436.029 uV, v_off_fin = 2427.702 uV 12:04:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.174 uVs 12:04:43 Integrated Voltage Measurement... 12:04:52 Voltage Offset Correction: v_off_ini = 2438.576 uV, v_off_fin = 2444.159 uV 12:04:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.976 uVs 12:04:52 Integrated Voltage Measurement... 12:05:01 Voltage Offset Correction: v_off_ini = 2408.876 uV, v_off_fin = 2426.261 uV 12:05:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -20.006 uVs 12:05:01 Integrated Voltage Measurement... 12:05:10 Voltage Offset Correction: v_off_ini = 2428.988 uV, v_off_fin = 2460.329 uV 12:05:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.746 uVs 12:05:12 I2X Average and RMS of Measurements VT = -31.178 +- 10.520 uVs I2X = 2.868 +- 0.968 uTm^2 12:05:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:05:20 Integrated Voltage Measurement... 12:05:29 Voltage Offset Correction: v_off_ini = 2464.496 uV, v_off_fin = 2444.082 uV 12:05:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.999 uVs 12:05:29 Integrated Voltage Measurement... 12:05:38 Voltage Offset Correction: v_off_ini = 2426.169 uV, v_off_fin = 2426.623 uV 12:05:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.645 uVs 12:05:38 Integrated Voltage Measurement... 12:05:47 Voltage Offset Correction: v_off_ini = 2425.409 uV, v_off_fin = 2403.120 uV 12:05:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.322 uVs 12:05:47 Integrated Voltage Measurement... 12:05:56 Voltage Offset Correction: v_off_ini = 2400.145 uV, v_off_fin = 2413.561 uV 12:05:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.598 uVs 12:05:56 Integrated Voltage Measurement... 12:06:05 Voltage Offset Correction: v_off_ini = 2397.428 uV, v_off_fin = 2380.823 uV 12:06:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.717 uVs 12:06:05 Integrated Voltage Measurement... 12:06:14 Voltage Offset Correction: v_off_ini = 2382.739 uV, v_off_fin = 2379.412 uV 12:06:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 269.374 uVs 12:06:16 I2Y Average and RMS of Measurements VT = -254.276 +- 20.478 uVs I2Y = -23.394 +- 1.885 uTm^2 12:06:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:06:35 Integrated Voltage Measurement... 12:06:44 Voltage Offset Correction: v_off_ini = 2373.103 uV, v_off_fin = 2362.603 uV 12:06:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -72.967 uVs 12:06:44 Integrated Voltage Measurement... 12:06:53 Voltage Offset Correction: v_off_ini = 2371.005 uV, v_off_fin = 2362.965 uV 12:06:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.057 uVs 12:06:53 Integrated Voltage Measurement... 12:07:02 Voltage Offset Correction: v_off_ini = 2337.104 uV, v_off_fin = 2352.179 uV 12:07:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -13.527 uVs 12:07:02 Integrated Voltage Measurement... 12:07:11 Voltage Offset Correction: v_off_ini = 2370.633 uV, v_off_fin = 2365.021 uV 12:07:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.286 uVs 12:07:11 Integrated Voltage Measurement... 12:07:20 Voltage Offset Correction: v_off_ini = 2362.863 uV, v_off_fin = 2359.545 uV 12:07:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.915 uVs 12:07:20 Integrated Voltage Measurement... 12:07:29 Voltage Offset Correction: v_off_ini = 2349.003 uV, v_off_fin = 2357.577 uV 12:07:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 50.857 uVs 12:07:33 I1X Average and RMS of Measurements VT = -51.435 +- 15.062 uVs I1X = 10.288 +- 3.013 uTm 12:07:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:40 Integrated Voltage Measurement... 12:07:49 Voltage Offset Correction: v_off_ini = 2361.333 uV, v_off_fin = 2351.000 uV 12:07:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.528 uVs 12:07:49 Integrated Voltage Measurement... 12:07:58 Voltage Offset Correction: v_off_ini = 2320.855 uV, v_off_fin = 2358.494 uV 12:07:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.462 uVs 12:07:58 Integrated Voltage Measurement... 12:08:07 Voltage Offset Correction: v_off_ini = 2358.908 uV, v_off_fin = 2331.884 uV 12:08:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.089 uVs 12:08:07 Integrated Voltage Measurement... 12:08:16 Voltage Offset Correction: v_off_ini = 2334.845 uV, v_off_fin = 2352.738 uV 12:08:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.274 uVs 12:08:16 Integrated Voltage Measurement... 12:08:25 Voltage Offset Correction: v_off_ini = 2332.639 uV, v_off_fin = 2319.384 uV 12:08:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.397 uVs 12:08:25 Integrated Voltage Measurement... 12:08:34 Voltage Offset Correction: v_off_ini = 2325.385 uV, v_off_fin = 2326.788 uV 12:08:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 171.271 uVs 12:08:38 I1Y Average and RMS of Measurements VT = -182.170 +- 9.126 uVs I1Y = -36.431 +- 1.825 uTm 12:08:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:08:46 Integrated Voltage Measurement... 12:08:55 Voltage Offset Correction: v_off_ini = 2309.173 uV, v_off_fin = 2308.777 uV 12:08:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -51.943 uVs 12:08:55 Integrated Voltage Measurement... 12:09:04 Voltage Offset Correction: v_off_ini = 2325.360 uV, v_off_fin = 2333.501 uV 12:09:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.286 uVs 12:09:04 Integrated Voltage Measurement... 12:09:13 Voltage Offset Correction: v_off_ini = 2302.912 uV, v_off_fin = 2333.525 uV 12:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.815 uVs 12:09:13 Integrated Voltage Measurement... 12:09:22 Voltage Offset Correction: v_off_ini = 2320.755 uV, v_off_fin = 2324.889 uV 12:09:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.954 uVs 12:09:22 Integrated Voltage Measurement... 12:09:31 Voltage Offset Correction: v_off_ini = 2347.481 uV, v_off_fin = 2360.804 uV 12:09:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.969 uVs 12:09:31 Integrated Voltage Measurement... 12:09:40 Voltage Offset Correction: v_off_ini = 2367.937 uV, v_off_fin = 2358.620 uV 12:09:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.998 uVs 12:09:42 I2X Average and RMS of Measurements VT = -42.494 +- 6.322 uVs I2X = 3.910 +- 0.582 uTm^2 12:09:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:50 Integrated Voltage Measurement... 12:09:59 Voltage Offset Correction: v_off_ini = 2348.646 uV, v_off_fin = 2355.883 uV 12:09:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.685 uVs 12:09:59 Integrated Voltage Measurement... 12:10:08 Voltage Offset Correction: v_off_ini = 2340.429 uV, v_off_fin = 2354.515 uV 12:10:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.876 uVs 12:10:08 Integrated Voltage Measurement... 12:10:17 Voltage Offset Correction: v_off_ini = 2341.199 uV, v_off_fin = 2362.770 uV 12:10:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.881 uVs 12:10:17 Integrated Voltage Measurement... 12:10:26 Voltage Offset Correction: v_off_ini = 2356.821 uV, v_off_fin = 2360.724 uV 12:10:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 238.640 uVs 12:10:26 Integrated Voltage Measurement... 12:10:35 Voltage Offset Correction: v_off_ini = 2347.227 uV, v_off_fin = 2346.076 uV 12:10:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.460 uVs 12:10:35 Integrated Voltage Measurement... 12:10:44 Voltage Offset Correction: v_off_ini = 2360.943 uV, v_off_fin = 2355.070 uV 12:10:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.742 uVs 12:10:47 I2Y Average and RMS of Measurements VT = -234.381 +- 7.667 uVs I2Y = -21.563 +- 0.706 uTm^2 12:11:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:11:05 Integrated Voltage Measurement... 12:11:14 Voltage Offset Correction: v_off_ini = 2377.162 uV, v_off_fin = 2366.995 uV 12:11:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.302 uVs 12:11:14 Integrated Voltage Measurement... 12:11:23 Voltage Offset Correction: v_off_ini = 2371.373 uV, v_off_fin = 2391.537 uV 12:11:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.161 uVs 12:11:23 Integrated Voltage Measurement... 12:11:32 Voltage Offset Correction: v_off_ini = 2369.858 uV, v_off_fin = 2370.391 uV 12:11:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.502 uVs 12:11:32 Integrated Voltage Measurement... 12:11:41 Voltage Offset Correction: v_off_ini = 2397.932 uV, v_off_fin = 2408.484 uV 12:11:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.691 uVs 12:11:41 Integrated Voltage Measurement... 12:11:50 Voltage Offset Correction: v_off_ini = 2369.923 uV, v_off_fin = 2413.941 uV 12:11:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.195 uVs 12:11:50 Integrated Voltage Measurement... 12:11:59 Voltage Offset Correction: v_off_ini = 2400.519 uV, v_off_fin = 2395.547 uV 12:11:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.888 uVs 12:12:03 I1X Average and RMS of Measurements VT = -53.790 +- 4.468 uVs I1X = 10.758 +- 0.894 uTm 12:12:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:12:10 Integrated Voltage Measurement... 12:12:19 Voltage Offset Correction: v_off_ini = 2348.678 uV, v_off_fin = 2362.808 uV 12:12:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.277 uVs 12:12:19 Integrated Voltage Measurement... 12:12:28 Voltage Offset Correction: v_off_ini = 2414.072 uV, v_off_fin = 2441.643 uV 12:12:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.675 uVs 12:12:28 Integrated Voltage Measurement... 12:12:37 Voltage Offset Correction: v_off_ini = 2380.954 uV, v_off_fin = 2386.395 uV 12:12:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.734 uVs 12:12:37 Integrated Voltage Measurement... 12:12:46 Voltage Offset Correction: v_off_ini = 2394.224 uV, v_off_fin = 2411.836 uV 12:12:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.394 uVs 12:12:46 Integrated Voltage Measurement... 12:12:55 Voltage Offset Correction: v_off_ini = 2387.823 uV, v_off_fin = 2385.493 uV 12:12:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.385 uVs 12:12:55 Integrated Voltage Measurement... 12:13:04 Voltage Offset Correction: v_off_ini = 2400.623 uV, v_off_fin = 2430.618 uV 12:13:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.384 uVs 12:13:08 I1Y Average and RMS of Measurements VT = -188.308 +- 6.924 uVs I1Y = -37.660 +- 1.385 uTm 12:13:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:13:16 Integrated Voltage Measurement... 12:13:25 Voltage Offset Correction: v_off_ini = 2424.976 uV, v_off_fin = 2422.867 uV 12:13:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.375 uVs 12:13:25 Integrated Voltage Measurement... 12:13:34 Voltage Offset Correction: v_off_ini = 2451.547 uV, v_off_fin = 2464.118 uV 12:13:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.169 uVs 12:13:34 Integrated Voltage Measurement... 12:13:43 Voltage Offset Correction: v_off_ini = 2418.445 uV, v_off_fin = 2461.628 uV 12:13:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.257 uVs 12:13:43 Integrated Voltage Measurement... 12:13:52 Voltage Offset Correction: v_off_ini = 2447.911 uV, v_off_fin = 2437.232 uV 12:13:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.299 uVs 12:13:52 Integrated Voltage Measurement... 12:14:01 Voltage Offset Correction: v_off_ini = 2421.327 uV, v_off_fin = 2419.892 uV 12:14:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.785 uVs 12:14:01 Integrated Voltage Measurement... 12:14:10 Voltage Offset Correction: v_off_ini = 2441.932 uV, v_off_fin = 2422.342 uV 12:14:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.073 uVs 12:14:12 I2X Average and RMS of Measurements VT = -40.826 +- 9.977 uVs I2X = 3.756 +- 0.918 uTm^2 12:14:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:14:20 Integrated Voltage Measurement... 12:14:29 Voltage Offset Correction: v_off_ini = 2424.156 uV, v_off_fin = 2424.189 uV 12:14:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -229.886 uVs 12:14:29 Integrated Voltage Measurement... 12:14:38 Voltage Offset Correction: v_off_ini = 2407.911 uV, v_off_fin = 2415.151 uV 12:14:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 257.808 uVs 12:14:38 Integrated Voltage Measurement... 12:14:47 Voltage Offset Correction: v_off_ini = 2417.110 uV, v_off_fin = 2412.354 uV 12:14:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -231.342 uVs 12:14:47 Integrated Voltage Measurement... 12:14:56 Voltage Offset Correction: v_off_ini = 2407.024 uV, v_off_fin = 2419.202 uV 12:14:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.381 uVs 12:14:56 Integrated Voltage Measurement... 12:15:05 Voltage Offset Correction: v_off_ini = 2431.497 uV, v_off_fin = 2418.151 uV 12:15:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.975 uVs 12:15:05 Integrated Voltage Measurement... 12:15:14 Voltage Offset Correction: v_off_ini = 2425.353 uV, v_off_fin = 2396.457 uV 12:15:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 263.070 uVs 12:15:17 I2Y Average and RMS of Measurements VT = -234.411 +- 8.440 uVs I2Y = -21.567 +- 0.777 uTm^2 12:15:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm