SLAC Magnetic Measurements Date: 07-31-2026 Time: 13:21:45 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16334 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 3 Measurement Device: Stretched Wire Operator: YL Comment: 13:21:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:21:57 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:21:58 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:22:00 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:22:01 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:24:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:24:29 Integrated Voltage Measurement... 13:24:38 Voltage Offset Correction: v_off_ini = 1736.272 uV, v_off_fin = 1762.549 uV 13:24:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -157.700 uVs 13:24:38 Integrated Voltage Measurement... 13:24:47 Voltage Offset Correction: v_off_ini = 1756.260 uV, v_off_fin = 1769.844 uV 13:24:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.800 uVs 13:24:47 Integrated Voltage Measurement... 13:24:56 Voltage Offset Correction: v_off_ini = 1725.766 uV, v_off_fin = 1759.930 uV 13:24:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.467 uVs 13:24:56 Integrated Voltage Measurement... 13:25:05 Voltage Offset Correction: v_off_ini = 1763.466 uV, v_off_fin = 1764.065 uV 13:25:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.663 uVs 13:25:05 Integrated Voltage Measurement... 13:25:14 Voltage Offset Correction: v_off_ini = 1760.138 uV, v_off_fin = 1743.174 uV 13:25:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.229 uVs 13:25:14 Integrated Voltage Measurement... 13:25:23 Voltage Offset Correction: v_off_ini = 1749.907 uV, v_off_fin = 1784.953 uV 13:25:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.287 uVs 13:25:27 I1X Average and RMS of Measurements VT = -113.691 +- 24.319 uVs I1X = 22.740 +- 4.865 uTm 13:25:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:25:34 Integrated Voltage Measurement... 13:25:43 Voltage Offset Correction: v_off_ini = 1782.393 uV, v_off_fin = 1729.658 uV 13:25:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.097 uVs 13:25:43 Integrated Voltage Measurement... 13:25:51 Voltage Offset Correction: v_off_ini = 1760.842 uV, v_off_fin = 1771.304 uV 13:25:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.694 uVs 13:25:52 Integrated Voltage Measurement... 13:26:01 Voltage Offset Correction: v_off_ini = 1729.716 uV, v_off_fin = 1772.606 uV 13:26:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.298 uVs 13:26:01 Integrated Voltage Measurement... 13:26:09 Voltage Offset Correction: v_off_ini = 1746.072 uV, v_off_fin = 1754.180 uV 13:26:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.750 uVs 13:26:10 Integrated Voltage Measurement... 13:26:18 Voltage Offset Correction: v_off_ini = 1777.966 uV, v_off_fin = 1770.774 uV 13:26:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.150 uVs 13:26:19 Integrated Voltage Measurement... 13:26:27 Voltage Offset Correction: v_off_ini = 1788.131 uV, v_off_fin = 1810.456 uV 13:26:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.054 uVs 13:26:32 I1Y Average and RMS of Measurements VT = -233.840 +- 7.680 uVs I1Y = -46.767 +- 1.537 uTm 13:26:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:26:39 Integrated Voltage Measurement... 13:26:48 Voltage Offset Correction: v_off_ini = 1782.966 uV, v_off_fin = 1799.313 uV 13:26:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.599 uVs 13:26:48 Integrated Voltage Measurement... 13:26:57 Voltage Offset Correction: v_off_ini = 1798.204 uV, v_off_fin = 1797.905 uV 13:26:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.149 uVs 13:26:57 Integrated Voltage Measurement... 13:27:06 Voltage Offset Correction: v_off_ini = 1817.197 uV, v_off_fin = 1801.844 uV 13:27:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.701 uVs 13:27:06 Integrated Voltage Measurement... 13:27:15 Voltage Offset Correction: v_off_ini = 1807.895 uV, v_off_fin = 1788.113 uV 13:27:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.536 uVs 13:27:15 Integrated Voltage Measurement... 13:27:24 Voltage Offset Correction: v_off_ini = 1796.004 uV, v_off_fin = 1794.905 uV 13:27:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.816 uVs 13:27:24 Integrated Voltage Measurement... 13:27:33 Voltage Offset Correction: v_off_ini = 1798.022 uV, v_off_fin = 1816.920 uV 13:27:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.533 uVs 13:27:36 I2X Average and RMS of Measurements VT = -118.556 +- 13.877 uVs I2X = 10.907 +- 1.277 uTm^2 13:27:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:27:44 Integrated Voltage Measurement... 13:27:53 Voltage Offset Correction: v_off_ini = 1784.491 uV, v_off_fin = 1829.442 uV 13:27:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -400.495 uVs 13:27:53 Integrated Voltage Measurement... 13:28:02 Voltage Offset Correction: v_off_ini = 1816.125 uV, v_off_fin = 1820.841 uV 13:28:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.099 uVs 13:28:02 Integrated Voltage Measurement... 13:28:11 Voltage Offset Correction: v_off_ini = 1838.053 uV, v_off_fin = 1801.224 uV 13:28:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -387.316 uVs 13:28:11 Integrated Voltage Measurement... 13:28:20 Voltage Offset Correction: v_off_ini = 1807.838 uV, v_off_fin = 1787.235 uV 13:28:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 392.084 uVs 13:28:20 Integrated Voltage Measurement... 13:28:29 Voltage Offset Correction: v_off_ini = 1804.058 uV, v_off_fin = 1823.491 uV 13:28:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -409.669 uVs 13:28:29 Integrated Voltage Measurement... 13:28:38 Voltage Offset Correction: v_off_ini = 1781.165 uV, v_off_fin = 1790.032 uV 13:28:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 396.694 uVs 13:28:40 I2Y Average and RMS of Measurements VT = -394.726 +- 6.014 uVs I2Y = -36.315 +- 0.553 uTm^2 13:28:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:28:55 Integrated Voltage Measurement... 13:29:04 Voltage Offset Correction: v_off_ini = 1812.792 uV, v_off_fin = 1803.273 uV 13:29:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.795 uVs 13:29:04 Integrated Voltage Measurement... 13:29:13 Voltage Offset Correction: v_off_ini = 1788.499 uV, v_off_fin = 1781.173 uV 13:29:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.409 uVs 13:29:13 Integrated Voltage Measurement... 13:29:22 Voltage Offset Correction: v_off_ini = 1793.734 uV, v_off_fin = 1834.679 uV 13:29:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.299 uVs 13:29:22 Integrated Voltage Measurement... 13:29:31 Voltage Offset Correction: v_off_ini = 1791.427 uV, v_off_fin = 1799.320 uV 13:29:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 123.092 uVs 13:29:31 Integrated Voltage Measurement... 13:29:40 Voltage Offset Correction: v_off_ini = 1777.723 uV, v_off_fin = 1763.281 uV 13:29:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.958 uVs 13:29:40 Integrated Voltage Measurement... 13:29:49 Voltage Offset Correction: v_off_ini = 1763.168 uV, v_off_fin = 1743.699 uV 13:29:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.091 uVs 13:29:53 I1X Average and RMS of Measurements VT = -114.107 +- 19.505 uVs I1X = 22.823 +- 3.901 uTm 13:29:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:30:00 Integrated Voltage Measurement... 13:30:09 Voltage Offset Correction: v_off_ini = 1800.313 uV, v_off_fin = 1799.704 uV 13:30:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.702 uVs 13:30:09 Integrated Voltage Measurement... 13:30:18 Voltage Offset Correction: v_off_ini = 1808.762 uV, v_off_fin = 1763.870 uV 13:30:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.371 uVs 13:30:18 Integrated Voltage Measurement... 13:30:27 Voltage Offset Correction: v_off_ini = 1756.719 uV, v_off_fin = 1756.937 uV 13:30:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -233.434 uVs 13:30:27 Integrated Voltage Measurement... 13:30:36 Voltage Offset Correction: v_off_ini = 1746.586 uV, v_off_fin = 1776.813 uV 13:30:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 266.060 uVs 13:30:36 Integrated Voltage Measurement... 13:30:45 Voltage Offset Correction: v_off_ini = 1768.412 uV, v_off_fin = 1769.242 uV 13:30:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.000 uVs 13:30:45 Integrated Voltage Measurement... 13:30:54 Voltage Offset Correction: v_off_ini = 1795.489 uV, v_off_fin = 1796.665 uV 13:30:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 244.737 uVs 13:30:58 I1Y Average and RMS of Measurements VT = -235.217 +- 10.546 uVs I1Y = -47.040 +- 2.108 uTm 13:31:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:31:06 Integrated Voltage Measurement... 13:31:15 Voltage Offset Correction: v_off_ini = 1749.788 uV, v_off_fin = 1770.730 uV 13:31:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.003 uVs 13:31:15 Integrated Voltage Measurement... 13:31:24 Voltage Offset Correction: v_off_ini = 1781.200 uV, v_off_fin = 1782.869 uV 13:31:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.883 uVs 13:31:24 Integrated Voltage Measurement... 13:31:33 Voltage Offset Correction: v_off_ini = 1732.650 uV, v_off_fin = 1747.237 uV 13:31:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -79.830 uVs 13:31:33 Integrated Voltage Measurement... 13:31:42 Voltage Offset Correction: v_off_ini = 1765.415 uV, v_off_fin = 1741.290 uV 13:31:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.764 uVs 13:31:42 Integrated Voltage Measurement... 13:31:51 Voltage Offset Correction: v_off_ini = 1754.335 uV, v_off_fin = 1757.610 uV 13:31:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.150 uVs 13:31:51 Integrated Voltage Measurement... 13:32:00 Voltage Offset Correction: v_off_ini = 1772.523 uV, v_off_fin = 1785.556 uV 13:32:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.704 uVs 13:32:02 I2X Average and RMS of Measurements VT = -103.722 +- 18.455 uVs I2X = 9.543 +- 1.698 uTm^2 13:32:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:32:10 Integrated Voltage Measurement... 13:32:19 Voltage Offset Correction: v_off_ini = 1771.864 uV, v_off_fin = 1771.384 uV 13:32:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.921 uVs 13:32:19 Integrated Voltage Measurement... 13:32:28 Voltage Offset Correction: v_off_ini = 1797.015 uV, v_off_fin = 1776.850 uV 13:32:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.038 uVs 13:32:28 Integrated Voltage Measurement... 13:32:37 Voltage Offset Correction: v_off_ini = 1779.088 uV, v_off_fin = 1739.476 uV 13:32:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -394.606 uVs 13:32:37 Integrated Voltage Measurement... 13:32:46 Voltage Offset Correction: v_off_ini = 1768.355 uV, v_off_fin = 1782.917 uV 13:32:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 400.558 uVs 13:32:46 Integrated Voltage Measurement... 13:32:55 Voltage Offset Correction: v_off_ini = 1790.323 uV, v_off_fin = 1762.259 uV 13:32:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.280 uVs 13:32:55 Integrated Voltage Measurement... 13:33:04 Voltage Offset Correction: v_off_ini = 1787.375 uV, v_off_fin = 1793.994 uV 13:33:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.305 uVs 13:33:07 I2Y Average and RMS of Measurements VT = -378.118 +- 13.966 uVs I2Y = -34.788 +- 1.287 uTm^2 13:33:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:33:22 Integrated Voltage Measurement... 13:33:30 Voltage Offset Correction: v_off_ini = 1773.010 uV, v_off_fin = 1781.118 uV 13:33:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -128.537 uVs 13:33:31 Integrated Voltage Measurement... 13:33:39 Voltage Offset Correction: v_off_ini = 1773.743 uV, v_off_fin = 1789.648 uV 13:33:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.895 uVs 13:33:40 Integrated Voltage Measurement... 13:33:48 Voltage Offset Correction: v_off_ini = 1753.816 uV, v_off_fin = 1739.422 uV 13:33:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.837 uVs 13:33:49 Integrated Voltage Measurement... 13:33:57 Voltage Offset Correction: v_off_ini = 1767.669 uV, v_off_fin = 1768.443 uV 13:33:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.625 uVs 13:33:58 Integrated Voltage Measurement... 13:34:07 Voltage Offset Correction: v_off_ini = 1791.415 uV, v_off_fin = 1789.597 uV 13:34:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.580 uVs 13:34:07 Integrated Voltage Measurement... 13:34:16 Voltage Offset Correction: v_off_ini = 1783.685 uV, v_off_fin = 1803.279 uV 13:34:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.793 uVs 13:34:20 I1X Average and RMS of Measurements VT = -110.878 +- 12.833 uVs I1X = 22.176 +- 2.567 uTm 13:34:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:26 Integrated Voltage Measurement... 13:34:35 Voltage Offset Correction: v_off_ini = 1761.468 uV, v_off_fin = 1755.795 uV 13:34:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -260.359 uVs 13:34:35 Integrated Voltage Measurement... 13:34:44 Voltage Offset Correction: v_off_ini = 1786.046 uV, v_off_fin = 1776.605 uV 13:34:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.998 uVs 13:34:44 Integrated Voltage Measurement... 13:34:53 Voltage Offset Correction: v_off_ini = 1773.331 uV, v_off_fin = 1751.948 uV 13:34:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -242.161 uVs 13:34:53 Integrated Voltage Measurement... 13:35:02 Voltage Offset Correction: v_off_ini = 1801.393 uV, v_off_fin = 1801.207 uV 13:35:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 245.269 uVs 13:35:02 Integrated Voltage Measurement... 13:35:11 Voltage Offset Correction: v_off_ini = 1769.569 uV, v_off_fin = 1746.657 uV 13:35:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.174 uVs 13:35:11 Integrated Voltage Measurement... 13:35:20 Voltage Offset Correction: v_off_ini = 1768.170 uV, v_off_fin = 1760.107 uV 13:35:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.033 uVs 13:35:25 I1Y Average and RMS of Measurements VT = -239.999 +- 13.355 uVs I1Y = -47.995 +- 2.671 uTm 13:35:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:32 Integrated Voltage Measurement... 13:35:41 Voltage Offset Correction: v_off_ini = 1780.463 uV, v_off_fin = 1784.810 uV 13:35:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.437 uVs 13:35:41 Integrated Voltage Measurement... 13:35:50 Voltage Offset Correction: v_off_ini = 1815.780 uV, v_off_fin = 1791.578 uV 13:35:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.058 uVs 13:35:50 Integrated Voltage Measurement... 13:35:59 Voltage Offset Correction: v_off_ini = 1787.308 uV, v_off_fin = 1783.418 uV 13:35:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.664 uVs 13:35:59 Integrated Voltage Measurement... 13:36:08 Voltage Offset Correction: v_off_ini = 1808.849 uV, v_off_fin = 1796.778 uV 13:36:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.297 uVs 13:36:08 Integrated Voltage Measurement... 13:36:17 Voltage Offset Correction: v_off_ini = 1826.002 uV, v_off_fin = 1802.749 uV 13:36:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -109.459 uVs 13:36:17 Integrated Voltage Measurement... 13:36:26 Voltage Offset Correction: v_off_ini = 1814.787 uV, v_off_fin = 1809.179 uV 13:36:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.189 uVs 13:36:29 I2X Average and RMS of Measurements VT = -116.017 +- 10.144 uVs I2X = 10.674 +- 0.933 uTm^2 13:36:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:36 Integrated Voltage Measurement... 13:36:45 Voltage Offset Correction: v_off_ini = 1810.016 uV, v_off_fin = 1802.547 uV 13:36:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.833 uVs 13:36:46 Integrated Voltage Measurement... 13:36:54 Voltage Offset Correction: v_off_ini = 1769.859 uV, v_off_fin = 1781.187 uV 13:36:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 416.761 uVs 13:36:55 Integrated Voltage Measurement... 13:37:04 Voltage Offset Correction: v_off_ini = 1736.780 uV, v_off_fin = 1786.727 uV 13:37:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -324.784 uVs 13:37:04 Integrated Voltage Measurement... 13:37:13 Voltage Offset Correction: v_off_ini = 1768.422 uV, v_off_fin = 1780.646 uV 13:37:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 384.661 uVs 13:37:13 Integrated Voltage Measurement... 13:37:22 Voltage Offset Correction: v_off_ini = 1767.209 uV, v_off_fin = 1813.091 uV 13:37:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.251 uVs 13:37:22 Integrated Voltage Measurement... 13:37:31 Voltage Offset Correction: v_off_ini = 1824.250 uV, v_off_fin = 1842.062 uV 13:37:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 368.629 uVs 13:37:33 I2Y Average and RMS of Measurements VT = -375.153 +- 16.182 uVs I2Y = -34.515 +- 1.488 uTm^2 13:37:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:37:48 Integrated Voltage Measurement... 13:37:57 Voltage Offset Correction: v_off_ini = 1795.765 uV, v_off_fin = 1753.591 uV 13:37:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.934 uVs 13:37:57 Integrated Voltage Measurement... 13:38:06 Voltage Offset Correction: v_off_ini = 1752.837 uV, v_off_fin = 1760.252 uV 13:38:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.130 uVs 13:38:06 Integrated Voltage Measurement... 13:38:15 Voltage Offset Correction: v_off_ini = 1766.909 uV, v_off_fin = 1776.543 uV 13:38:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.203 uVs 13:38:15 Integrated Voltage Measurement... 13:38:24 Voltage Offset Correction: v_off_ini = 1738.887 uV, v_off_fin = 1737.402 uV 13:38:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.089 uVs 13:38:24 Integrated Voltage Measurement... 13:38:33 Voltage Offset Correction: v_off_ini = 1708.125 uV, v_off_fin = 1738.802 uV 13:38:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.232 uVs 13:38:33 Integrated Voltage Measurement... 13:38:42 Voltage Offset Correction: v_off_ini = 1733.691 uV, v_off_fin = 1745.158 uV 13:38:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.578 uVs 13:38:46 I1X Average and RMS of Measurements VT = -114.361 +- 6.502 uVs I1X = 22.872 +- 1.300 uTm 13:38:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:38:53 Integrated Voltage Measurement... 13:39:02 Voltage Offset Correction: v_off_ini = 1758.994 uV, v_off_fin = 1747.443 uV 13:39:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -227.572 uVs 13:39:02 Integrated Voltage Measurement... 13:39:11 Voltage Offset Correction: v_off_ini = 1747.276 uV, v_off_fin = 1759.981 uV 13:39:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.593 uVs 13:39:11 Integrated Voltage Measurement... 13:39:20 Voltage Offset Correction: v_off_ini = 1741.375 uV, v_off_fin = 1717.586 uV 13:39:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.883 uVs 13:39:20 Integrated Voltage Measurement... 13:39:29 Voltage Offset Correction: v_off_ini = 1741.438 uV, v_off_fin = 1779.066 uV 13:39:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.619 uVs 13:39:29 Integrated Voltage Measurement... 13:39:38 Voltage Offset Correction: v_off_ini = 1755.495 uV, v_off_fin = 1759.072 uV 13:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -254.434 uVs 13:39:38 Integrated Voltage Measurement... 13:39:47 Voltage Offset Correction: v_off_ini = 1790.209 uV, v_off_fin = 1804.656 uV 13:39:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 238.010 uVs 13:39:51 I1Y Average and RMS of Measurements VT = -229.352 +- 12.565 uVs I1Y = -45.866 +- 2.513 uTm 13:39:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:39:59 Integrated Voltage Measurement... 13:40:08 Voltage Offset Correction: v_off_ini = 1788.317 uV, v_off_fin = 1759.250 uV 13:40:08 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -85.306 uVs 13:40:08 Integrated Voltage Measurement... 13:40:17 Voltage Offset Correction: v_off_ini = 1790.060 uV, v_off_fin = 1786.567 uV 13:40:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.373 uVs 13:40:17 Integrated Voltage Measurement... 13:40:26 Voltage Offset Correction: v_off_ini = 1769.705 uV, v_off_fin = 1775.376 uV 13:40:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -131.177 uVs 13:40:26 Integrated Voltage Measurement... 13:40:35 Voltage Offset Correction: v_off_ini = 1801.367 uV, v_off_fin = 1814.915 uV 13:40:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.717 uVs 13:40:35 Integrated Voltage Measurement... 13:40:44 Voltage Offset Correction: v_off_ini = 1800.359 uV, v_off_fin = 1754.953 uV 13:40:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.911 uVs 13:40:44 Integrated Voltage Measurement... 13:40:53 Voltage Offset Correction: v_off_ini = 1754.532 uV, v_off_fin = 1732.607 uV 13:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.935 uVs 13:40:55 I2X Average and RMS of Measurements VT = -109.903 +- 19.861 uVs I2X = 10.111 +- 1.828 uTm^2 13:41:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:41:03 Integrated Voltage Measurement... 13:41:12 Voltage Offset Correction: v_off_ini = 1765.577 uV, v_off_fin = 1799.233 uV 13:41:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.981 uVs 13:41:12 Integrated Voltage Measurement... 13:41:21 Voltage Offset Correction: v_off_ini = 1781.431 uV, v_off_fin = 1780.168 uV 13:41:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.462 uVs 13:41:21 Integrated Voltage Measurement... 13:41:30 Voltage Offset Correction: v_off_ini = 1765.156 uV, v_off_fin = 1739.609 uV 13:41:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.188 uVs 13:41:30 Integrated Voltage Measurement... 13:41:39 Voltage Offset Correction: v_off_ini = 1788.570 uV, v_off_fin = 1783.778 uV 13:41:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.567 uVs 13:41:39 Integrated Voltage Measurement... 13:41:48 Voltage Offset Correction: v_off_ini = 1795.464 uV, v_off_fin = 1832.819 uV 13:41:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.506 uVs 13:41:48 Integrated Voltage Measurement... 13:41:57 Voltage Offset Correction: v_off_ini = 1808.014 uV, v_off_fin = 1783.696 uV 13:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.993 uVs 13:42:00 I2Y Average and RMS of Measurements VT = -342.450 +- 6.182 uVs I2Y = -31.505 +- 0.569 uTm^2 13:42:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:42:15 Integrated Voltage Measurement... 13:42:24 Voltage Offset Correction: v_off_ini = 1827.463 uV, v_off_fin = 1824.273 uV 13:42:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.855 uVs 13:42:24 Integrated Voltage Measurement... 13:42:33 Voltage Offset Correction: v_off_ini = 1800.462 uV, v_off_fin = 1827.732 uV 13:42:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.215 uVs 13:42:33 Integrated Voltage Measurement... 13:42:42 Voltage Offset Correction: v_off_ini = 1789.191 uV, v_off_fin = 1749.887 uV 13:42:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.688 uVs 13:42:42 Integrated Voltage Measurement... 13:42:51 Voltage Offset Correction: v_off_ini = 1771.593 uV, v_off_fin = 1766.392 uV 13:42:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.321 uVs 13:42:51 Integrated Voltage Measurement... 13:43:00 Voltage Offset Correction: v_off_ini = 1767.358 uV, v_off_fin = 1779.864 uV 13:43:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.028 uVs 13:43:00 Integrated Voltage Measurement... 13:43:09 Voltage Offset Correction: v_off_ini = 1778.741 uV, v_off_fin = 1763.634 uV 13:43:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.984 uVs 13:43:13 I1X Average and RMS of Measurements VT = -118.015 +- 9.231 uVs I1X = 23.603 +- 1.846 uTm 13:43:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:43:20 Integrated Voltage Measurement... 13:43:28 Voltage Offset Correction: v_off_ini = 1786.246 uV, v_off_fin = 1766.090 uV 13:43:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.663 uVs 13:43:29 Integrated Voltage Measurement... 13:43:37 Voltage Offset Correction: v_off_ini = 1759.330 uV, v_off_fin = 1737.044 uV 13:43:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.161 uVs 13:43:38 Integrated Voltage Measurement... 13:43:46 Voltage Offset Correction: v_off_ini = 1754.813 uV, v_off_fin = 1754.717 uV 13:43:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.514 uVs 13:43:46 Integrated Voltage Measurement... 13:43:55 Voltage Offset Correction: v_off_ini = 1800.729 uV, v_off_fin = 1794.665 uV 13:43:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.670 uVs 13:43:55 Integrated Voltage Measurement... 13:44:04 Voltage Offset Correction: v_off_ini = 1803.050 uV, v_off_fin = 1767.095 uV 13:44:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.556 uVs 13:44:04 Integrated Voltage Measurement... 13:44:13 Voltage Offset Correction: v_off_ini = 1747.860 uV, v_off_fin = 1766.084 uV 13:44:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.131 uVs 13:44:18 I1Y Average and RMS of Measurements VT = -210.616 +- 8.153 uVs I1Y = -42.119 +- 1.630 uTm 13:44:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:44:25 Integrated Voltage Measurement... 13:44:34 Voltage Offset Correction: v_off_ini = 1753.293 uV, v_off_fin = 1752.244 uV 13:44:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.011 uVs 13:44:34 Integrated Voltage Measurement... 13:44:43 Voltage Offset Correction: v_off_ini = 1763.325 uV, v_off_fin = 1785.491 uV 13:44:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.897 uVs 13:44:43 Integrated Voltage Measurement... 13:44:52 Voltage Offset Correction: v_off_ini = 1773.484 uV, v_off_fin = 1784.661 uV 13:44:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.286 uVs 13:44:52 Integrated Voltage Measurement... 13:45:01 Voltage Offset Correction: v_off_ini = 1773.168 uV, v_off_fin = 1794.362 uV 13:45:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.340 uVs 13:45:01 Integrated Voltage Measurement... 13:45:10 Voltage Offset Correction: v_off_ini = 1786.553 uV, v_off_fin = 1802.475 uV 13:45:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -114.499 uVs 13:45:10 Integrated Voltage Measurement... 13:45:19 Voltage Offset Correction: v_off_ini = 1757.850 uV, v_off_fin = 1817.203 uV 13:45:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 155.851 uVs 13:45:22 I2X Average and RMS of Measurements VT = -126.314 +- 7.510 uVs I2X = 11.621 +- 0.691 uTm^2 13:45:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:29 Integrated Voltage Measurement... 13:45:38 Voltage Offset Correction: v_off_ini = 1822.098 uV, v_off_fin = 1794.623 uV 13:45:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -352.461 uVs 13:45:38 Integrated Voltage Measurement... 13:45:47 Voltage Offset Correction: v_off_ini = 1813.164 uV, v_off_fin = 1778.979 uV 13:45:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.530 uVs 13:45:47 Integrated Voltage Measurement... 13:45:56 Voltage Offset Correction: v_off_ini = 1775.261 uV, v_off_fin = 1782.496 uV 13:45:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.916 uVs 13:45:57 Integrated Voltage Measurement... 13:46:05 Voltage Offset Correction: v_off_ini = 1762.139 uV, v_off_fin = 1773.702 uV 13:46:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 389.980 uVs 13:46:06 Integrated Voltage Measurement... 13:46:15 Voltage Offset Correction: v_off_ini = 1795.384 uV, v_off_fin = 1783.398 uV 13:46:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.588 uVs 13:46:15 Integrated Voltage Measurement... 13:46:24 Voltage Offset Correction: v_off_ini = 1788.173 uV, v_off_fin = 1786.784 uV 13:46:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 385.925 uVs 13:46:26 I2Y Average and RMS of Measurements VT = -346.567 +- 12.781 uVs I2Y = -31.885 +- 1.176 uTm^2 13:46:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:41 Integrated Voltage Measurement... 13:46:50 Voltage Offset Correction: v_off_ini = 1845.388 uV, v_off_fin = 1843.354 uV 13:46:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.637 uVs 13:46:50 Integrated Voltage Measurement... 13:46:59 Voltage Offset Correction: v_off_ini = 1800.296 uV, v_off_fin = 1824.921 uV 13:46:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.913 uVs 13:46:59 Integrated Voltage Measurement... 13:47:08 Voltage Offset Correction: v_off_ini = 1783.625 uV, v_off_fin = 1823.549 uV 13:47:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.277 uVs 13:47:08 Integrated Voltage Measurement... 13:47:17 Voltage Offset Correction: v_off_ini = 1829.555 uV, v_off_fin = 1855.159 uV 13:47:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.274 uVs 13:47:17 Integrated Voltage Measurement... 13:47:26 Voltage Offset Correction: v_off_ini = 1820.052 uV, v_off_fin = 1816.286 uV 13:47:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.802 uVs 13:47:26 Integrated Voltage Measurement... 13:47:35 Voltage Offset Correction: v_off_ini = 1797.117 uV, v_off_fin = 1808.826 uV 13:47:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.336 uVs 13:47:39 I1X Average and RMS of Measurements VT = -113.707 +- 23.476 uVs I1X = 22.741 +- 4.695 uTm 13:47:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:47:46 Integrated Voltage Measurement... 13:47:55 Voltage Offset Correction: v_off_ini = 1815.648 uV, v_off_fin = 1803.788 uV 13:47:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.606 uVs 13:47:55 Integrated Voltage Measurement... 13:48:04 Voltage Offset Correction: v_off_ini = 1794.150 uV, v_off_fin = 1794.333 uV 13:48:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.513 uVs 13:48:04 Integrated Voltage Measurement... 13:48:13 Voltage Offset Correction: v_off_ini = 1824.746 uV, v_off_fin = 1792.546 uV 13:48:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.497 uVs 13:48:13 Integrated Voltage Measurement... 13:48:22 Voltage Offset Correction: v_off_ini = 1781.090 uV, v_off_fin = 1830.229 uV 13:48:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.816 uVs 13:48:22 Integrated Voltage Measurement... 13:48:31 Voltage Offset Correction: v_off_ini = 1836.070 uV, v_off_fin = 1829.821 uV 13:48:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.525 uVs 13:48:31 Integrated Voltage Measurement... 13:48:40 Voltage Offset Correction: v_off_ini = 1849.720 uV, v_off_fin = 1847.459 uV 13:48:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.492 uVs 13:48:44 I1Y Average and RMS of Measurements VT = -204.408 +- 12.695 uVs I1Y = -40.878 +- 2.539 uTm 13:48:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:52 Integrated Voltage Measurement... 13:49:01 Voltage Offset Correction: v_off_ini = 1803.119 uV, v_off_fin = 1824.688 uV 13:49:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.029 uVs 13:49:01 Integrated Voltage Measurement... 13:49:10 Voltage Offset Correction: v_off_ini = 1821.273 uV, v_off_fin = 1856.169 uV 13:49:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.225 uVs 13:49:10 Integrated Voltage Measurement... 13:49:19 Voltage Offset Correction: v_off_ini = 1839.190 uV, v_off_fin = 1835.647 uV 13:49:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.127 uVs 13:49:19 Integrated Voltage Measurement... 13:49:28 Voltage Offset Correction: v_off_ini = 1835.973 uV, v_off_fin = 1849.057 uV 13:49:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.555 uVs 13:49:28 Integrated Voltage Measurement... 13:49:37 Voltage Offset Correction: v_off_ini = 1780.855 uV, v_off_fin = 1800.368 uV 13:49:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.268 uVs 13:49:37 Integrated Voltage Measurement... 13:49:46 Voltage Offset Correction: v_off_ini = 1846.193 uV, v_off_fin = 1854.205 uV 13:49:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.125 uVs 13:49:48 I2X Average and RMS of Measurements VT = -118.721 +- 10.504 uVs I2X = 10.922 +- 0.966 uTm^2 13:49:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:49:56 Integrated Voltage Measurement... 13:50:05 Voltage Offset Correction: v_off_ini = 1815.837 uV, v_off_fin = 1831.149 uV 13:50:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.481 uVs 13:50:05 Integrated Voltage Measurement... 13:50:14 Voltage Offset Correction: v_off_ini = 1846.095 uV, v_off_fin = 1839.359 uV 13:50:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.262 uVs 13:50:14 Integrated Voltage Measurement... 13:50:23 Voltage Offset Correction: v_off_ini = 1843.472 uV, v_off_fin = 1844.082 uV 13:50:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.101 uVs 13:50:23 Integrated Voltage Measurement... 13:50:32 Voltage Offset Correction: v_off_ini = 1857.480 uV, v_off_fin = 1826.324 uV 13:50:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.695 uVs 13:50:32 Integrated Voltage Measurement... 13:50:41 Voltage Offset Correction: v_off_ini = 1841.065 uV, v_off_fin = 1850.498 uV 13:50:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.712 uVs 13:50:41 Integrated Voltage Measurement... 13:50:50 Voltage Offset Correction: v_off_ini = 1825.199 uV, v_off_fin = 1830.358 uV 13:50:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.478 uVs 13:50:52 I2Y Average and RMS of Measurements VT = -329.288 +- 2.685 uVs I2Y = -30.294 +- 0.247 uTm^2 13:51:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:07 Integrated Voltage Measurement... 13:51:16 Voltage Offset Correction: v_off_ini = 1838.644 uV, v_off_fin = 1834.334 uV 13:51:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -67.252 uVs 13:51:16 Integrated Voltage Measurement... 13:51:25 Voltage Offset Correction: v_off_ini = 1824.818 uV, v_off_fin = 1833.838 uV 13:51:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.679 uVs 13:51:25 Integrated Voltage Measurement... 13:51:34 Voltage Offset Correction: v_off_ini = 1810.869 uV, v_off_fin = 1829.900 uV 13:51:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.571 uVs 13:51:34 Integrated Voltage Measurement... 13:51:43 Voltage Offset Correction: v_off_ini = 1817.658 uV, v_off_fin = 1810.503 uV 13:51:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.575 uVs 13:51:43 Integrated Voltage Measurement... 13:51:52 Voltage Offset Correction: v_off_ini = 1789.731 uV, v_off_fin = 1820.265 uV 13:51:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.540 uVs 13:51:52 Integrated Voltage Measurement... 13:52:01 Voltage Offset Correction: v_off_ini = 1819.994 uV, v_off_fin = 1818.850 uV 13:52:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.533 uVs 13:52:06 I1X Average and RMS of Measurements VT = -106.525 +- 5.677 uVs I1X = 21.306 +- 1.135 uTm 13:52:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:12 Integrated Voltage Measurement... 13:52:21 Voltage Offset Correction: v_off_ini = 1795.112 uV, v_off_fin = 1785.861 uV 13:52:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.020 uVs 13:52:21 Integrated Voltage Measurement... 13:52:30 Voltage Offset Correction: v_off_ini = 1803.242 uV, v_off_fin = 1817.933 uV 13:52:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.924 uVs 13:52:30 Integrated Voltage Measurement... 13:52:39 Voltage Offset Correction: v_off_ini = 1806.058 uV, v_off_fin = 1799.863 uV 13:52:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.147 uVs 13:52:39 Integrated Voltage Measurement... 13:52:48 Voltage Offset Correction: v_off_ini = 1775.809 uV, v_off_fin = 1805.849 uV 13:52:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.408 uVs 13:52:48 Integrated Voltage Measurement... 13:52:57 Voltage Offset Correction: v_off_ini = 1856.429 uV, v_off_fin = 1814.633 uV 13:52:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.691 uVs 13:52:57 Integrated Voltage Measurement... 13:53:06 Voltage Offset Correction: v_off_ini = 1832.410 uV, v_off_fin = 1837.881 uV 13:53:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.601 uVs 13:53:10 I1Y Average and RMS of Measurements VT = -189.299 +- 8.926 uVs I1Y = -37.858 +- 1.785 uTm 13:53:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:18 Integrated Voltage Measurement... 13:53:27 Voltage Offset Correction: v_off_ini = 1810.160 uV, v_off_fin = 1830.120 uV 13:53:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.124 uVs 13:53:27 Integrated Voltage Measurement... 13:53:36 Voltage Offset Correction: v_off_ini = 1822.603 uV, v_off_fin = 1814.281 uV 13:53:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.583 uVs 13:53:36 Integrated Voltage Measurement... 13:53:45 Voltage Offset Correction: v_off_ini = 1839.628 uV, v_off_fin = 1860.335 uV 13:53:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.757 uVs 13:53:45 Integrated Voltage Measurement... 13:53:54 Voltage Offset Correction: v_off_ini = 1835.296 uV, v_off_fin = 1814.610 uV 13:53:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.723 uVs 13:53:54 Integrated Voltage Measurement... 13:54:03 Voltage Offset Correction: v_off_ini = 1837.112 uV, v_off_fin = 1819.920 uV 13:54:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -159.156 uVs 13:54:03 Integrated Voltage Measurement... 13:54:12 Voltage Offset Correction: v_off_ini = 1787.748 uV, v_off_fin = 1815.986 uV 13:54:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.485 uVs 13:54:15 I2X Average and RMS of Measurements VT = -124.971 +- 12.188 uVs I2X = 11.498 +- 1.121 uTm^2 13:54:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:22 Integrated Voltage Measurement... 13:54:31 Voltage Offset Correction: v_off_ini = 1799.346 uV, v_off_fin = 1813.835 uV 13:54:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.752 uVs 13:54:31 Integrated Voltage Measurement... 13:54:40 Voltage Offset Correction: v_off_ini = 1827.518 uV, v_off_fin = 1811.318 uV 13:54:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.447 uVs 13:54:40 Integrated Voltage Measurement... 13:54:49 Voltage Offset Correction: v_off_ini = 1807.633 uV, v_off_fin = 1830.384 uV 13:54:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.231 uVs 13:54:50 Integrated Voltage Measurement... 13:54:58 Voltage Offset Correction: v_off_ini = 1817.837 uV, v_off_fin = 1841.826 uV 13:54:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.988 uVs 13:54:59 Integrated Voltage Measurement... 13:55:08 Voltage Offset Correction: v_off_ini = 1815.092 uV, v_off_fin = 1790.158 uV 13:55:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.252 uVs 13:55:08 Integrated Voltage Measurement... 13:55:17 Voltage Offset Correction: v_off_ini = 1821.818 uV, v_off_fin = 1850.592 uV 13:55:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.620 uVs 13:55:19 I2Y Average and RMS of Measurements VT = -329.382 +- 2.339 uVs I2Y = -30.303 +- 0.215 uTm^2 13:55:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:34 Integrated Voltage Measurement... 13:55:43 Voltage Offset Correction: v_off_ini = 1844.873 uV, v_off_fin = 1826.445 uV 13:55:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -158.580 uVs 13:55:43 Integrated Voltage Measurement... 13:55:52 Voltage Offset Correction: v_off_ini = 1790.716 uV, v_off_fin = 1820.075 uV 13:55:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.721 uVs 13:55:52 Integrated Voltage Measurement... 13:56:01 Voltage Offset Correction: v_off_ini = 1806.719 uV, v_off_fin = 1811.792 uV 13:56:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.931 uVs 13:56:01 Integrated Voltage Measurement... 13:56:10 Voltage Offset Correction: v_off_ini = 1839.239 uV, v_off_fin = 1812.135 uV 13:56:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.416 uVs 13:56:10 Integrated Voltage Measurement... 13:56:19 Voltage Offset Correction: v_off_ini = 1802.613 uV, v_off_fin = 1836.527 uV 13:56:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.618 uVs 13:56:19 Integrated Voltage Measurement... 13:56:28 Voltage Offset Correction: v_off_ini = 1862.802 uV, v_off_fin = 1874.163 uV 13:56:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.347 uVs 13:56:32 I1X Average and RMS of Measurements VT = -117.935 +- 11.238 uVs I1X = 23.589 +- 2.250 uTm 13:56:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:39 Integrated Voltage Measurement... 13:56:48 Voltage Offset Correction: v_off_ini = 1854.339 uV, v_off_fin = 1831.620 uV 13:56:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.197 uVs 13:56:48 Integrated Voltage Measurement... 13:56:57 Voltage Offset Correction: v_off_ini = 1887.474 uV, v_off_fin = 1873.328 uV 13:56:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.428 uVs 13:56:57 Integrated Voltage Measurement... 13:57:06 Voltage Offset Correction: v_off_ini = 1887.354 uV, v_off_fin = 1848.697 uV 13:57:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.522 uVs 13:57:06 Integrated Voltage Measurement... 13:57:15 Voltage Offset Correction: v_off_ini = 1887.785 uV, v_off_fin = 1903.816 uV 13:57:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.827 uVs 13:57:15 Integrated Voltage Measurement... 13:57:24 Voltage Offset Correction: v_off_ini = 1857.461 uV, v_off_fin = 1860.409 uV 13:57:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.673 uVs 13:57:24 Integrated Voltage Measurement... 13:57:33 Voltage Offset Correction: v_off_ini = 1855.819 uV, v_off_fin = 1838.959 uV 13:57:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.700 uVs 13:57:37 I1Y Average and RMS of Measurements VT = -188.058 +- 6.442 uVs I1Y = -37.610 +- 1.288 uTm 13:57:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:45 Integrated Voltage Measurement... 13:57:54 Voltage Offset Correction: v_off_ini = 1857.626 uV, v_off_fin = 1839.664 uV 13:57:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.918 uVs 13:57:54 Integrated Voltage Measurement... 13:58:03 Voltage Offset Correction: v_off_ini = 1838.483 uV, v_off_fin = 1879.597 uV 13:58:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.721 uVs 13:58:03 Integrated Voltage Measurement... 13:58:12 Voltage Offset Correction: v_off_ini = 1863.700 uV, v_off_fin = 1864.820 uV 13:58:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.777 uVs 13:58:12 Integrated Voltage Measurement... 13:58:21 Voltage Offset Correction: v_off_ini = 1844.397 uV, v_off_fin = 1865.730 uV 13:58:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.982 uVs 13:58:21 Integrated Voltage Measurement... 13:58:30 Voltage Offset Correction: v_off_ini = 1861.901 uV, v_off_fin = 1860.784 uV 13:58:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.887 uVs 13:58:30 Integrated Voltage Measurement... 13:58:39 Voltage Offset Correction: v_off_ini = 1880.498 uV, v_off_fin = 1865.898 uV 13:58:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 145.756 uVs 13:58:41 I2X Average and RMS of Measurements VT = -124.840 +- 12.088 uVs I2X = 11.486 +- 1.112 uTm^2 13:58:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:49 Integrated Voltage Measurement... 13:58:58 Voltage Offset Correction: v_off_ini = 1854.111 uV, v_off_fin = 1855.046 uV 13:58:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -366.948 uVs 13:58:58 Integrated Voltage Measurement... 13:59:07 Voltage Offset Correction: v_off_ini = 1888.214 uV, v_off_fin = 1904.166 uV 13:59:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.045 uVs 13:59:07 Integrated Voltage Measurement... 13:59:16 Voltage Offset Correction: v_off_ini = 1899.758 uV, v_off_fin = 1917.560 uV 13:59:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.150 uVs 13:59:16 Integrated Voltage Measurement... 13:59:25 Voltage Offset Correction: v_off_ini = 1887.688 uV, v_off_fin = 1887.215 uV 13:59:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.807 uVs 13:59:25 Integrated Voltage Measurement... 13:59:34 Voltage Offset Correction: v_off_ini = 1892.686 uV, v_off_fin = 1874.935 uV 13:59:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.606 uVs 13:59:34 Integrated Voltage Measurement... 13:59:43 Voltage Offset Correction: v_off_ini = 1859.135 uV, v_off_fin = 1871.590 uV 13:59:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.094 uVs 13:59:46 I2Y Average and RMS of Measurements VT = -338.442 +- 14.616 uVs I2Y = -31.137 +- 1.345 uTm^2 13:59:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:01 Integrated Voltage Measurement... 14:00:10 Voltage Offset Correction: v_off_ini = 1891.310 uV, v_off_fin = 1855.299 uV 14:00:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -179.824 uVs 14:00:10 Integrated Voltage Measurement... 14:00:19 Voltage Offset Correction: v_off_ini = 1869.628 uV, v_off_fin = 1905.084 uV 14:00:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.865 uVs 14:00:19 Integrated Voltage Measurement... 14:00:28 Voltage Offset Correction: v_off_ini = 1860.922 uV, v_off_fin = 1853.125 uV 14:00:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.591 uVs 14:00:28 Integrated Voltage Measurement... 14:00:37 Voltage Offset Correction: v_off_ini = 1877.801 uV, v_off_fin = 1893.412 uV 14:00:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.686 uVs 14:00:37 Integrated Voltage Measurement... 14:00:46 Voltage Offset Correction: v_off_ini = 1889.791 uV, v_off_fin = 1859.508 uV 14:00:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -108.372 uVs 14:00:46 Integrated Voltage Measurement... 14:00:55 Voltage Offset Correction: v_off_ini = 1825.733 uV, v_off_fin = 1844.791 uV 14:00:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.204 uVs 14:00:59 I1X Average and RMS of Measurements VT = -122.090 +- 15.738 uVs I1X = 24.419 +- 3.148 uTm 14:01:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:06 Integrated Voltage Measurement... 14:01:14 Voltage Offset Correction: v_off_ini = 1877.371 uV, v_off_fin = 1856.509 uV 14:01:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -196.889 uVs 14:01:15 Integrated Voltage Measurement... 14:01:23 Voltage Offset Correction: v_off_ini = 1865.859 uV, v_off_fin = 1865.934 uV 14:01:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.263 uVs 14:01:24 Integrated Voltage Measurement... 14:01:32 Voltage Offset Correction: v_off_ini = 1867.410 uV, v_off_fin = 1884.164 uV 14:01:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.868 uVs 14:01:33 Integrated Voltage Measurement... 14:01:41 Voltage Offset Correction: v_off_ini = 1871.272 uV, v_off_fin = 1876.514 uV 14:01:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.235 uVs 14:01:42 Integrated Voltage Measurement... 14:01:50 Voltage Offset Correction: v_off_ini = 1905.056 uV, v_off_fin = 1907.146 uV 14:01:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.731 uVs 14:01:51 Integrated Voltage Measurement... 14:01:59 Voltage Offset Correction: v_off_ini = 1904.103 uV, v_off_fin = 1908.028 uV 14:01:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.317 uVs 14:02:04 I1Y Average and RMS of Measurements VT = -195.550 +- 6.564 uVs I1Y = -39.107 +- 1.312 uTm 14:02:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:11 Integrated Voltage Measurement... 14:02:20 Voltage Offset Correction: v_off_ini = 1885.726 uV, v_off_fin = 1918.676 uV 14:02:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.784 uVs 14:02:20 Integrated Voltage Measurement... 14:02:29 Voltage Offset Correction: v_off_ini = 1883.522 uV, v_off_fin = 1913.984 uV 14:02:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.802 uVs 14:02:29 Integrated Voltage Measurement... 14:02:38 Voltage Offset Correction: v_off_ini = 1879.706 uV, v_off_fin = 1846.003 uV 14:02:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.310 uVs 14:02:38 Integrated Voltage Measurement... 14:02:47 Voltage Offset Correction: v_off_ini = 1914.347 uV, v_off_fin = 1934.918 uV 14:02:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.976 uVs 14:02:48 Integrated Voltage Measurement... 14:02:56 Voltage Offset Correction: v_off_ini = 1898.403 uV, v_off_fin = 1887.815 uV 14:02:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.930 uVs 14:02:57 Integrated Voltage Measurement... 14:03:06 Voltage Offset Correction: v_off_ini = 1920.366 uV, v_off_fin = 1928.848 uV 14:03:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.313 uVs 14:03:08 I2X Average and RMS of Measurements VT = -112.853 +- 16.996 uVs I2X = 10.382 +- 1.564 uTm^2 14:03:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:03:16 Integrated Voltage Measurement... 14:03:25 Voltage Offset Correction: v_off_ini = 1917.008 uV, v_off_fin = 1910.275 uV 14:03:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.322 uVs 14:03:25 Integrated Voltage Measurement... 14:03:34 Voltage Offset Correction: v_off_ini = 1851.594 uV, v_off_fin = 1876.443 uV 14:03:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.684 uVs 14:03:34 Integrated Voltage Measurement... 14:03:43 Voltage Offset Correction: v_off_ini = 1901.705 uV, v_off_fin = 1895.967 uV 14:03:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.258 uVs 14:03:43 Integrated Voltage Measurement... 14:03:52 Voltage Offset Correction: v_off_ini = 1878.466 uV, v_off_fin = 1908.445 uV 14:03:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.195 uVs 14:03:52 Integrated Voltage Measurement... 14:04:01 Voltage Offset Correction: v_off_ini = 1898.592 uV, v_off_fin = 1906.021 uV 14:04:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.710 uVs 14:04:01 Integrated Voltage Measurement... 14:04:10 Voltage Offset Correction: v_off_ini = 1882.502 uV, v_off_fin = 1905.552 uV 14:04:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.747 uVs 14:04:12 I2Y Average and RMS of Measurements VT = -319.153 +- 12.717 uVs I2Y = -29.362 +- 1.170 uTm^2 14:04:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:27 Integrated Voltage Measurement... 14:04:36 Voltage Offset Correction: v_off_ini = 1926.190 uV, v_off_fin = 1897.636 uV 14:04:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -85.162 uVs 14:04:36 Integrated Voltage Measurement... 14:04:45 Voltage Offset Correction: v_off_ini = 1899.983 uV, v_off_fin = 1945.134 uV 14:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.099 uVs 14:04:45 Integrated Voltage Measurement... 14:04:54 Voltage Offset Correction: v_off_ini = 1953.203 uV, v_off_fin = 1982.447 uV 14:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.779 uVs 14:04:54 Integrated Voltage Measurement... 14:05:03 Voltage Offset Correction: v_off_ini = 1974.801 uV, v_off_fin = 1959.484 uV 14:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 110.788 uVs 14:05:03 Integrated Voltage Measurement... 14:05:12 Voltage Offset Correction: v_off_ini = 1963.197 uV, v_off_fin = 1969.971 uV 14:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.720 uVs 14:05:12 Integrated Voltage Measurement... 14:05:21 Voltage Offset Correction: v_off_ini = 1963.966 uV, v_off_fin = 1962.275 uV 14:05:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.583 uVs 14:05:25 I1X Average and RMS of Measurements VT = -115.189 +- 11.989 uVs I1X = 23.039 +- 2.397 uTm 14:05:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:32 Integrated Voltage Measurement... 14:05:41 Voltage Offset Correction: v_off_ini = 1990.899 uV, v_off_fin = 1961.634 uV 14:05:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.663 uVs 14:05:41 Integrated Voltage Measurement... 14:05:50 Voltage Offset Correction: v_off_ini = 1970.888 uV, v_off_fin = 1970.929 uV 14:05:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.039 uVs 14:05:50 Integrated Voltage Measurement... 14:05:59 Voltage Offset Correction: v_off_ini = 1966.736 uV, v_off_fin = 1937.442 uV 14:05:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -196.354 uVs 14:05:59 Integrated Voltage Measurement... 14:06:08 Voltage Offset Correction: v_off_ini = 1972.358 uV, v_off_fin = 1945.996 uV 14:06:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.989 uVs 14:06:08 Integrated Voltage Measurement... 14:06:17 Voltage Offset Correction: v_off_ini = 1942.344 uV, v_off_fin = 1945.971 uV 14:06:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -165.164 uVs 14:06:17 Integrated Voltage Measurement... 14:06:26 Voltage Offset Correction: v_off_ini = 1955.877 uV, v_off_fin = 1967.012 uV 14:06:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.975 uVs 14:06:30 I1Y Average and RMS of Measurements VT = -188.364 +- 9.517 uVs I1Y = -37.670 +- 1.902 uTm 14:06:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:38 Integrated Voltage Measurement... 14:06:47 Voltage Offset Correction: v_off_ini = 1953.670 uV, v_off_fin = 1971.107 uV 14:06:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.859 uVs 14:06:47 Integrated Voltage Measurement... 14:06:56 Voltage Offset Correction: v_off_ini = 1996.837 uV, v_off_fin = 1980.968 uV 14:06:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 144.528 uVs 14:06:56 Integrated Voltage Measurement... 14:07:05 Voltage Offset Correction: v_off_ini = 1998.427 uV, v_off_fin = 2001.387 uV 14:07:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.297 uVs 14:07:05 Integrated Voltage Measurement... 14:07:14 Voltage Offset Correction: v_off_ini = 1989.530 uV, v_off_fin = 2025.815 uV 14:07:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.193 uVs 14:07:14 Integrated Voltage Measurement... 14:07:23 Voltage Offset Correction: v_off_ini = 2017.343 uV, v_off_fin = 2015.379 uV 14:07:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.743 uVs 14:07:23 Integrated Voltage Measurement... 14:07:32 Voltage Offset Correction: v_off_ini = 2019.782 uV, v_off_fin = 2034.943 uV 14:07:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.361 uVs 14:07:35 I2X Average and RMS of Measurements VT = -128.997 +- 8.182 uVs I2X = 11.868 +- 0.753 uTm^2 14:07:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:07:42 Integrated Voltage Measurement... 14:07:51 Voltage Offset Correction: v_off_ini = 2011.606 uV, v_off_fin = 1969.575 uV 14:07:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.777 uVs 14:07:51 Integrated Voltage Measurement... 14:08:00 Voltage Offset Correction: v_off_ini = 1978.215 uV, v_off_fin = 2001.112 uV 14:08:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.497 uVs 14:08:00 Integrated Voltage Measurement... 14:08:09 Voltage Offset Correction: v_off_ini = 1973.474 uV, v_off_fin = 2016.073 uV 14:08:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -257.847 uVs 14:08:09 Integrated Voltage Measurement... 14:08:18 Voltage Offset Correction: v_off_ini = 2018.666 uV, v_off_fin = 1989.648 uV 14:08:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.825 uVs 14:08:18 Integrated Voltage Measurement... 14:08:27 Voltage Offset Correction: v_off_ini = 2055.776 uV, v_off_fin = 2048.002 uV 14:08:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.679 uVs 14:08:28 Integrated Voltage Measurement... 14:08:36 Voltage Offset Correction: v_off_ini = 2046.821 uV, v_off_fin = 2068.302 uV 14:08:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 268.121 uVs 14:08:39 I2Y Average and RMS of Measurements VT = -293.291 +- 19.706 uVs I2Y = -26.984 +- 1.812 uTm^2 14:08:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:54 Integrated Voltage Measurement... 14:09:03 Voltage Offset Correction: v_off_ini = 2047.097 uV, v_off_fin = 2058.420 uV 14:09:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.152 uVs 14:09:03 Integrated Voltage Measurement... 14:09:12 Voltage Offset Correction: v_off_ini = 2020.596 uV, v_off_fin = 2059.803 uV 14:09:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.244 uVs 14:09:12 Integrated Voltage Measurement... 14:09:21 Voltage Offset Correction: v_off_ini = 2024.471 uV, v_off_fin = 2074.918 uV 14:09:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.085 uVs 14:09:21 Integrated Voltage Measurement... 14:09:30 Voltage Offset Correction: v_off_ini = 2039.110 uV, v_off_fin = 2056.550 uV 14:09:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.644 uVs 14:09:30 Integrated Voltage Measurement... 14:09:39 Voltage Offset Correction: v_off_ini = 2062.773 uV, v_off_fin = 2054.882 uV 14:09:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.896 uVs 14:09:39 Integrated Voltage Measurement... 14:09:48 Voltage Offset Correction: v_off_ini = 2071.882 uV, v_off_fin = 2076.070 uV 14:09:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.677 uVs 14:09:52 I1X Average and RMS of Measurements VT = -107.616 +- 7.799 uVs I1X = 21.523 +- 1.560 uTm 14:09:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:59 Integrated Voltage Measurement... 14:10:08 Voltage Offset Correction: v_off_ini = 2073.430 uV, v_off_fin = 2041.874 uV 14:10:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.799 uVs 14:10:08 Integrated Voltage Measurement... 14:10:17 Voltage Offset Correction: v_off_ini = 2092.725 uV, v_off_fin = 2068.207 uV 14:10:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 185.232 uVs 14:10:17 Integrated Voltage Measurement... 14:10:26 Voltage Offset Correction: v_off_ini = 2059.514 uV, v_off_fin = 2020.428 uV 14:10:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.259 uVs 14:10:26 Integrated Voltage Measurement... 14:10:35 Voltage Offset Correction: v_off_ini = 2037.545 uV, v_off_fin = 2063.420 uV 14:10:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.359 uVs 14:10:35 Integrated Voltage Measurement... 14:10:44 Voltage Offset Correction: v_off_ini = 2090.287 uV, v_off_fin = 2069.442 uV 14:10:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.143 uVs 14:10:44 Integrated Voltage Measurement... 14:10:53 Voltage Offset Correction: v_off_ini = 2058.368 uV, v_off_fin = 2062.193 uV 14:10:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.466 uVs 14:10:57 I1Y Average and RMS of Measurements VT = -191.209 +- 7.904 uVs I1Y = -38.241 +- 1.581 uTm 14:11:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:05 Integrated Voltage Measurement... 14:11:14 Voltage Offset Correction: v_off_ini = 2050.756 uV, v_off_fin = 2038.294 uV 14:11:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.240 uVs 14:11:14 Integrated Voltage Measurement... 14:11:23 Voltage Offset Correction: v_off_ini = 2051.973 uV, v_off_fin = 2076.886 uV 14:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.899 uVs 14:11:23 Integrated Voltage Measurement... 14:11:32 Voltage Offset Correction: v_off_ini = 2088.440 uV, v_off_fin = 2076.168 uV 14:11:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -122.377 uVs 14:11:32 Integrated Voltage Measurement... 14:11:41 Voltage Offset Correction: v_off_ini = 2053.944 uV, v_off_fin = 2070.978 uV 14:11:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 67.734 uVs 14:11:41 Integrated Voltage Measurement... 14:11:50 Voltage Offset Correction: v_off_ini = 2074.815 uV, v_off_fin = 2079.115 uV 14:11:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.858 uVs 14:11:50 Integrated Voltage Measurement... 14:11:59 Voltage Offset Correction: v_off_ini = 2087.694 uV, v_off_fin = 2101.591 uV 14:11:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.720 uVs 14:12:01 I2X Average and RMS of Measurements VT = -107.805 +- 9.110 uVs I2X = 9.919 +- 0.838 uTm^2 14:12:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:12:09 Integrated Voltage Measurement... 14:12:18 Voltage Offset Correction: v_off_ini = 2052.269 uV, v_off_fin = 2048.168 uV 14:12:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.001 uVs 14:12:18 Integrated Voltage Measurement... 14:12:27 Voltage Offset Correction: v_off_ini = 2093.540 uV, v_off_fin = 2076.456 uV 14:12:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.605 uVs 14:12:27 Integrated Voltage Measurement... 14:12:36 Voltage Offset Correction: v_off_ini = 2069.453 uV, v_off_fin = 2045.763 uV 14:12:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.224 uVs 14:12:36 Integrated Voltage Measurement... 14:12:45 Voltage Offset Correction: v_off_ini = 2067.554 uV, v_off_fin = 2061.169 uV 14:12:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.612 uVs 14:12:45 Integrated Voltage Measurement... 14:12:54 Voltage Offset Correction: v_off_ini = 2051.031 uV, v_off_fin = 2061.293 uV 14:12:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.119 uVs 14:12:54 Integrated Voltage Measurement... 14:13:03 Voltage Offset Correction: v_off_ini = 2067.309 uV, v_off_fin = 2038.818 uV 14:13:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.349 uVs 14:13:06 I2Y Average and RMS of Measurements VT = -310.818 +- 1.845 uVs I2Y = -28.595 +- 0.170 uTm^2 14:13:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:13:22 Integrated Voltage Measurement... 14:13:31 Voltage Offset Correction: v_off_ini = 2070.013 uV, v_off_fin = 2055.555 uV 14:13:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -76.397 uVs 14:13:31 Integrated Voltage Measurement... 14:13:40 Voltage Offset Correction: v_off_ini = 2077.620 uV, v_off_fin = 2056.232 uV 14:13:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.368 uVs 14:13:40 Integrated Voltage Measurement... 14:13:49 Voltage Offset Correction: v_off_ini = 2047.132 uV, v_off_fin = 2077.266 uV 14:13:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.803 uVs 14:13:49 Integrated Voltage Measurement... 14:13:58 Voltage Offset Correction: v_off_ini = 2079.335 uV, v_off_fin = 2062.501 uV 14:13:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.031 uVs 14:13:58 Integrated Voltage Measurement... 14:14:07 Voltage Offset Correction: v_off_ini = 2067.316 uV, v_off_fin = 2068.488 uV 14:14:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.175 uVs 14:14:07 Integrated Voltage Measurement... 14:14:16 Voltage Offset Correction: v_off_ini = 2091.442 uV, v_off_fin = 2099.327 uV 14:14:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.373 uVs 14:14:20 I1X Average and RMS of Measurements VT = -86.191 +- 7.088 uVs I1X = 17.239 +- 1.418 uTm 14:14:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:27 Integrated Voltage Measurement... 14:14:36 Voltage Offset Correction: v_off_ini = 2084.977 uV, v_off_fin = 2074.028 uV 14:14:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.554 uVs 14:14:36 Integrated Voltage Measurement... 14:14:45 Voltage Offset Correction: v_off_ini = 2115.521 uV, v_off_fin = 2119.911 uV 14:14:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.649 uVs 14:14:45 Integrated Voltage Measurement... 14:14:54 Voltage Offset Correction: v_off_ini = 2067.694 uV, v_off_fin = 2054.556 uV 14:14:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -196.755 uVs 14:14:54 Integrated Voltage Measurement... 14:15:03 Voltage Offset Correction: v_off_ini = 2055.228 uV, v_off_fin = 2078.805 uV 14:15:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.697 uVs 14:15:03 Integrated Voltage Measurement... 14:15:12 Voltage Offset Correction: v_off_ini = 2060.809 uV, v_off_fin = 2069.175 uV 14:15:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.777 uVs 14:15:12 Integrated Voltage Measurement... 14:15:21 Voltage Offset Correction: v_off_ini = 2072.665 uV, v_off_fin = 2080.698 uV 14:15:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.375 uVs 14:15:25 I1Y Average and RMS of Measurements VT = -186.801 +- 15.971 uVs I1Y = -37.359 +- 3.194 uTm 14:15:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:15:33 Integrated Voltage Measurement... 14:15:42 Voltage Offset Correction: v_off_ini = 2051.408 uV, v_off_fin = 2043.750 uV 14:15:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.598 uVs 14:15:42 Integrated Voltage Measurement... 14:15:51 Voltage Offset Correction: v_off_ini = 2047.389 uV, v_off_fin = 2068.132 uV 14:15:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.255 uVs 14:15:51 Integrated Voltage Measurement... 14:16:00 Voltage Offset Correction: v_off_ini = 2046.053 uV, v_off_fin = 2035.277 uV 14:16:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -134.866 uVs 14:16:00 Integrated Voltage Measurement... 14:16:09 Voltage Offset Correction: v_off_ini = 2057.060 uV, v_off_fin = 2058.808 uV 14:16:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 48.459 uVs 14:16:09 Integrated Voltage Measurement... 14:16:18 Voltage Offset Correction: v_off_ini = 2027.935 uV, v_off_fin = 2009.531 uV 14:16:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.326 uVs 14:16:18 Integrated Voltage Measurement... 14:16:27 Voltage Offset Correction: v_off_ini = 2030.468 uV, v_off_fin = 2044.968 uV 14:16:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.236 uVs 14:16:29 I2X Average and RMS of Measurements VT = -89.457 +- 14.433 uVs I2X = 8.230 +- 1.328 uTm^2 14:16:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:37 Integrated Voltage Measurement... 14:16:46 Voltage Offset Correction: v_off_ini = 2048.845 uV, v_off_fin = 2048.928 uV 14:16:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.793 uVs 14:16:46 Integrated Voltage Measurement... 14:16:55 Voltage Offset Correction: v_off_ini = 2083.075 uV, v_off_fin = 2096.379 uV 14:16:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.817 uVs 14:16:55 Integrated Voltage Measurement... 14:17:04 Voltage Offset Correction: v_off_ini = 2103.154 uV, v_off_fin = 2079.229 uV 14:17:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.911 uVs 14:17:04 Integrated Voltage Measurement... 14:17:13 Voltage Offset Correction: v_off_ini = 2069.688 uV, v_off_fin = 2076.284 uV 14:17:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.128 uVs 14:17:13 Integrated Voltage Measurement... 14:17:22 Voltage Offset Correction: v_off_ini = 2102.119 uV, v_off_fin = 2087.924 uV 14:17:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.456 uVs 14:17:22 Integrated Voltage Measurement... 14:17:31 Voltage Offset Correction: v_off_ini = 2075.452 uV, v_off_fin = 2064.369 uV 14:17:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.223 uVs 14:17:33 I2Y Average and RMS of Measurements VT = -307.721 +- 14.259 uVs I2Y = -28.310 +- 1.312 uTm^2 14:17:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:49 Integrated Voltage Measurement... 14:17:58 Voltage Offset Correction: v_off_ini = 2082.749 uV, v_off_fin = 2087.678 uV 14:17:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.060 uVs 14:17:58 Integrated Voltage Measurement... 14:18:07 Voltage Offset Correction: v_off_ini = 2089.337 uV, v_off_fin = 2102.501 uV 14:18:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.905 uVs 14:18:07 Integrated Voltage Measurement... 14:18:16 Voltage Offset Correction: v_off_ini = 2095.212 uV, v_off_fin = 2096.335 uV 14:18:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.574 uVs 14:18:16 Integrated Voltage Measurement... 14:18:25 Voltage Offset Correction: v_off_ini = 2118.140 uV, v_off_fin = 2118.287 uV 14:18:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.777 uVs 14:18:25 Integrated Voltage Measurement... 14:18:34 Voltage Offset Correction: v_off_ini = 2106.236 uV, v_off_fin = 2096.531 uV 14:18:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.099 uVs 14:18:34 Integrated Voltage Measurement... 14:18:43 Voltage Offset Correction: v_off_ini = 2070.641 uV, v_off_fin = 2093.954 uV 14:18:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.233 uVs 14:18:48 I1X Average and RMS of Measurements VT = -80.108 +- 10.628 uVs I1X = 16.022 +- 2.126 uTm 14:18:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:54 Integrated Voltage Measurement... 14:19:03 Voltage Offset Correction: v_off_ini = 2116.533 uV, v_off_fin = 2102.191 uV 14:19:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.837 uVs 14:19:03 Integrated Voltage Measurement... 14:19:12 Voltage Offset Correction: v_off_ini = 2124.877 uV, v_off_fin = 2120.577 uV 14:19:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.853 uVs 14:19:12 Integrated Voltage Measurement... 14:19:21 Voltage Offset Correction: v_off_ini = 2096.229 uV, v_off_fin = 2081.475 uV 14:19:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.185 uVs 14:19:21 Integrated Voltage Measurement... 14:19:30 Voltage Offset Correction: v_off_ini = 2113.499 uV, v_off_fin = 2117.725 uV 14:19:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.031 uVs 14:19:30 Integrated Voltage Measurement... 14:19:39 Voltage Offset Correction: v_off_ini = 2101.853 uV, v_off_fin = 2123.396 uV 14:19:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.023 uVs 14:19:39 Integrated Voltage Measurement... 14:19:48 Voltage Offset Correction: v_off_ini = 2108.585 uV, v_off_fin = 2109.199 uV 14:19:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.055 uVs 14:19:53 I1Y Average and RMS of Measurements VT = -192.997 +- 5.565 uVs I1Y = -38.596 +- 1.113 uTm 14:19:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:00 Integrated Voltage Measurement... 14:20:09 Voltage Offset Correction: v_off_ini = 2073.711 uV, v_off_fin = 2142.797 uV 14:20:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.876 uVs 14:20:09 Integrated Voltage Measurement... 14:20:18 Voltage Offset Correction: v_off_ini = 2124.810 uV, v_off_fin = 2157.194 uV 14:20:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.139 uVs 14:20:18 Integrated Voltage Measurement... 14:20:27 Voltage Offset Correction: v_off_ini = 2113.321 uV, v_off_fin = 2144.942 uV 14:20:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.372 uVs 14:20:27 Integrated Voltage Measurement... 14:20:36 Voltage Offset Correction: v_off_ini = 2146.475 uV, v_off_fin = 2154.915 uV 14:20:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.205 uVs 14:20:36 Integrated Voltage Measurement... 14:20:45 Voltage Offset Correction: v_off_ini = 2152.418 uV, v_off_fin = 2135.780 uV 14:20:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.080 uVs 14:20:45 Integrated Voltage Measurement... 14:20:54 Voltage Offset Correction: v_off_ini = 2138.299 uV, v_off_fin = 2169.867 uV 14:20:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.343 uVs 14:20:57 I2X Average and RMS of Measurements VT = -84.169 +- 10.697 uVs I2X = 7.744 +- 0.984 uTm^2 14:21:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:21:04 Integrated Voltage Measurement... 14:21:13 Voltage Offset Correction: v_off_ini = 2173.862 uV, v_off_fin = 2169.929 uV 14:21:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -271.524 uVs 14:21:13 Integrated Voltage Measurement... 14:21:22 Voltage Offset Correction: v_off_ini = 2156.786 uV, v_off_fin = 2166.844 uV 14:21:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.006 uVs 14:21:22 Integrated Voltage Measurement... 14:21:31 Voltage Offset Correction: v_off_ini = 2164.168 uV, v_off_fin = 2161.050 uV 14:21:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.635 uVs 14:21:31 Integrated Voltage Measurement... 14:21:40 Voltage Offset Correction: v_off_ini = 2147.902 uV, v_off_fin = 2164.873 uV 14:21:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.737 uVs 14:21:40 Integrated Voltage Measurement... 14:21:49 Voltage Offset Correction: v_off_ini = 2143.887 uV, v_off_fin = 2157.120 uV 14:21:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.958 uVs 14:21:49 Integrated Voltage Measurement... 14:21:58 Voltage Offset Correction: v_off_ini = 2149.152 uV, v_off_fin = 2141.407 uV 14:21:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.220 uVs 14:22:01 I2Y Average and RMS of Measurements VT = -276.180 +- 14.139 uVs I2Y = -25.409 +- 1.301 uTm^2 14:22:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:22:19 Integrated Voltage Measurement... 14:22:28 Voltage Offset Correction: v_off_ini = 2131.466 uV, v_off_fin = 2147.140 uV 14:22:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.754 uVs 14:22:28 Integrated Voltage Measurement... 14:22:37 Voltage Offset Correction: v_off_ini = 2122.361 uV, v_off_fin = 2151.579 uV 14:22:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.372 uVs 14:22:37 Integrated Voltage Measurement... 14:22:46 Voltage Offset Correction: v_off_ini = 2180.670 uV, v_off_fin = 2178.483 uV 14:22:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.676 uVs 14:22:46 Integrated Voltage Measurement... 14:22:55 Voltage Offset Correction: v_off_ini = 2166.832 uV, v_off_fin = 2193.057 uV 14:22:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.919 uVs 14:22:55 Integrated Voltage Measurement... 14:23:04 Voltage Offset Correction: v_off_ini = 2190.203 uV, v_off_fin = 2179.414 uV 14:23:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.679 uVs 14:23:04 Integrated Voltage Measurement... 14:23:13 Voltage Offset Correction: v_off_ini = 2190.262 uV, v_off_fin = 2177.728 uV 14:23:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.458 uVs 14:23:18 I1X Average and RMS of Measurements VT = -82.143 +- 15.487 uVs I1X = 16.429 +- 3.097 uTm 14:23:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:23:24 Integrated Voltage Measurement... 14:23:33 Voltage Offset Correction: v_off_ini = 2184.414 uV, v_off_fin = 2171.140 uV 14:23:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.065 uVs 14:23:33 Integrated Voltage Measurement... 14:23:42 Voltage Offset Correction: v_off_ini = 2190.989 uV, v_off_fin = 2179.730 uV 14:23:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.561 uVs 14:23:42 Integrated Voltage Measurement... 14:23:51 Voltage Offset Correction: v_off_ini = 2212.014 uV, v_off_fin = 2188.158 uV 14:23:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.305 uVs 14:23:51 Integrated Voltage Measurement... 14:24:00 Voltage Offset Correction: v_off_ini = 2192.336 uV, v_off_fin = 2211.113 uV 14:24:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.318 uVs 14:24:00 Integrated Voltage Measurement... 14:24:09 Voltage Offset Correction: v_off_ini = 2179.587 uV, v_off_fin = 2158.070 uV 14:24:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.032 uVs 14:24:09 Integrated Voltage Measurement... 14:24:18 Voltage Offset Correction: v_off_ini = 2147.225 uV, v_off_fin = 2168.031 uV 14:24:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.712 uVs 14:24:22 I1Y Average and RMS of Measurements VT = -188.332 +- 2.295 uVs I1Y = -37.663 +- 0.459 uTm 14:24:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:24:30 Integrated Voltage Measurement... 14:24:39 Voltage Offset Correction: v_off_ini = 2176.356 uV, v_off_fin = 2161.922 uV 14:24:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -41.421 uVs 14:24:39 Integrated Voltage Measurement... 14:24:48 Voltage Offset Correction: v_off_ini = 2170.201 uV, v_off_fin = 2186.422 uV 14:24:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.874 uVs 14:24:48 Integrated Voltage Measurement... 14:24:57 Voltage Offset Correction: v_off_ini = 2174.588 uV, v_off_fin = 2127.278 uV 14:24:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -7.937 uVs 14:24:57 Integrated Voltage Measurement... 14:25:06 Voltage Offset Correction: v_off_ini = 2160.577 uV, v_off_fin = 2186.130 uV 14:25:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.955 uVs 14:25:06 Integrated Voltage Measurement... 14:25:15 Voltage Offset Correction: v_off_ini = 2183.288 uV, v_off_fin = 2168.356 uV 14:25:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.096 uVs 14:25:15 Integrated Voltage Measurement... 14:25:24 Voltage Offset Correction: v_off_ini = 2189.888 uV, v_off_fin = 2178.909 uV 14:25:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.353 uVs 14:25:27 I2X Average and RMS of Measurements VT = -63.106 +- 10.817 uVs I2X = 5.806 +- 0.995 uTm^2 14:25:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:25:34 Integrated Voltage Measurement... 14:25:43 Voltage Offset Correction: v_off_ini = 2174.247 uV, v_off_fin = 2176.007 uV 14:25:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.700 uVs 14:25:43 Integrated Voltage Measurement... 14:25:52 Voltage Offset Correction: v_off_ini = 2194.716 uV, v_off_fin = 2180.489 uV 14:25:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.722 uVs 14:25:52 Integrated Voltage Measurement... 14:26:01 Voltage Offset Correction: v_off_ini = 2175.466 uV, v_off_fin = 2162.849 uV 14:26:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.354 uVs 14:26:01 Integrated Voltage Measurement... 14:26:10 Voltage Offset Correction: v_off_ini = 2161.797 uV, v_off_fin = 2159.298 uV 14:26:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.052 uVs 14:26:10 Integrated Voltage Measurement... 14:26:19 Voltage Offset Correction: v_off_ini = 2177.365 uV, v_off_fin = 2158.109 uV 14:26:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.162 uVs 14:26:19 Integrated Voltage Measurement... 14:26:28 Voltage Offset Correction: v_off_ini = 2169.623 uV, v_off_fin = 2164.116 uV 14:26:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.673 uVs 14:26:31 I2Y Average and RMS of Measurements VT = -254.110 +- 5.653 uVs I2Y = -23.378 +- 0.520 uTm^2 14:26:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:49 Integrated Voltage Measurement... 14:26:58 Voltage Offset Correction: v_off_ini = 2186.493 uV, v_off_fin = 2185.066 uV 14:26:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -75.244 uVs 14:26:58 Integrated Voltage Measurement... 14:27:07 Voltage Offset Correction: v_off_ini = 2194.400 uV, v_off_fin = 2201.150 uV 14:27:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.543 uVs 14:27:07 Integrated Voltage Measurement... 14:27:16 Voltage Offset Correction: v_off_ini = 2199.926 uV, v_off_fin = 2191.713 uV 14:27:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.003 uVs 14:27:16 Integrated Voltage Measurement... 14:27:25 Voltage Offset Correction: v_off_ini = 2179.085 uV, v_off_fin = 2182.864 uV 14:27:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.731 uVs 14:27:25 Integrated Voltage Measurement... 14:27:34 Voltage Offset Correction: v_off_ini = 2165.619 uV, v_off_fin = 2165.651 uV 14:27:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.455 uVs 14:27:34 Integrated Voltage Measurement... 14:27:43 Voltage Offset Correction: v_off_ini = 2191.687 uV, v_off_fin = 2196.505 uV 14:27:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.485 uVs 14:27:47 I1X Average and RMS of Measurements VT = -61.577 +- 10.211 uVs I1X = 12.316 +- 2.042 uTm 14:27:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:27:54 Integrated Voltage Measurement... 14:28:03 Voltage Offset Correction: v_off_ini = 2231.825 uV, v_off_fin = 2191.694 uV 14:28:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -163.589 uVs 14:28:03 Integrated Voltage Measurement... 14:28:12 Voltage Offset Correction: v_off_ini = 2192.660 uV, v_off_fin = 2215.208 uV 14:28:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.937 uVs 14:28:12 Integrated Voltage Measurement... 14:28:21 Voltage Offset Correction: v_off_ini = 2209.214 uV, v_off_fin = 2186.284 uV 14:28:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -133.487 uVs 14:28:21 Integrated Voltage Measurement... 14:28:30 Voltage Offset Correction: v_off_ini = 2195.713 uV, v_off_fin = 2205.786 uV 14:28:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.617 uVs 14:28:30 Integrated Voltage Measurement... 14:28:39 Voltage Offset Correction: v_off_ini = 2226.595 uV, v_off_fin = 2201.457 uV 14:28:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.765 uVs 14:28:39 Integrated Voltage Measurement... 14:28:48 Voltage Offset Correction: v_off_ini = 2189.915 uV, v_off_fin = 2238.600 uV 14:28:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.479 uVs 14:28:52 I1Y Average and RMS of Measurements VT = -174.646 +- 7.786 uVs I1Y = -34.926 +- 1.557 uTm 14:28:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:00 Integrated Voltage Measurement... 14:29:09 Voltage Offset Correction: v_off_ini = 2185.224 uV, v_off_fin = 2211.901 uV 14:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.173 uVs 14:29:09 Integrated Voltage Measurement... 14:29:18 Voltage Offset Correction: v_off_ini = 2210.897 uV, v_off_fin = 2191.418 uV 14:29:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.615 uVs 14:29:18 Integrated Voltage Measurement... 14:29:27 Voltage Offset Correction: v_off_ini = 2192.229 uV, v_off_fin = 2178.362 uV 14:29:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -7.467 uVs 14:29:27 Integrated Voltage Measurement... 14:29:36 Voltage Offset Correction: v_off_ini = 2204.574 uV, v_off_fin = 2210.484 uV 14:29:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.260 uVs 14:29:36 Integrated Voltage Measurement... 14:29:45 Voltage Offset Correction: v_off_ini = 2197.302 uV, v_off_fin = 2212.095 uV 14:29:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.384 uVs 14:29:45 Integrated Voltage Measurement... 14:29:54 Voltage Offset Correction: v_off_ini = 2227.767 uV, v_off_fin = 2221.791 uV 14:29:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.732 uVs 14:29:56 I2X Average and RMS of Measurements VT = -39.939 +- 6.638 uVs I2X = 3.674 +- 0.611 uTm^2 14:30:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:30:04 Integrated Voltage Measurement... 14:30:13 Voltage Offset Correction: v_off_ini = 2202.768 uV, v_off_fin = 2222.814 uV 14:30:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.300 uVs 14:30:13 Integrated Voltage Measurement... 14:30:22 Voltage Offset Correction: v_off_ini = 2233.987 uV, v_off_fin = 2227.323 uV 14:30:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.806 uVs 14:30:22 Integrated Voltage Measurement... 14:30:31 Voltage Offset Correction: v_off_ini = 2222.613 uV, v_off_fin = 2221.915 uV 14:30:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.261 uVs 14:30:31 Integrated Voltage Measurement... 14:30:40 Voltage Offset Correction: v_off_ini = 2205.626 uV, v_off_fin = 2205.434 uV 14:30:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.768 uVs 14:30:40 Integrated Voltage Measurement... 14:30:49 Voltage Offset Correction: v_off_ini = 2215.401 uV, v_off_fin = 2207.397 uV 14:30:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.399 uVs 14:30:49 Integrated Voltage Measurement... 14:30:58 Voltage Offset Correction: v_off_ini = 2209.032 uV, v_off_fin = 2192.270 uV 14:30:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.657 uVs 14:31:01 I2Y Average and RMS of Measurements VT = -257.032 +- 13.706 uVs I2Y = -23.647 +- 1.261 uTm^2 14:31:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:31:19 Integrated Voltage Measurement... 14:31:28 Voltage Offset Correction: v_off_ini = 2210.392 uV, v_off_fin = 2214.565 uV 14:31:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.271 uVs 14:31:28 Integrated Voltage Measurement... 14:31:37 Voltage Offset Correction: v_off_ini = 2234.045 uV, v_off_fin = 2237.978 uV 14:31:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.019 uVs 14:31:37 Integrated Voltage Measurement... 14:31:46 Voltage Offset Correction: v_off_ini = 2255.506 uV, v_off_fin = 2242.391 uV 14:31:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.848 uVs 14:31:46 Integrated Voltage Measurement... 14:31:55 Voltage Offset Correction: v_off_ini = 2236.446 uV, v_off_fin = 2242.686 uV 14:31:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.767 uVs 14:31:55 Integrated Voltage Measurement... 14:32:04 Voltage Offset Correction: v_off_ini = 2218.198 uV, v_off_fin = 2221.946 uV 14:32:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.259 uVs 14:32:04 Integrated Voltage Measurement... 14:32:13 Voltage Offset Correction: v_off_ini = 2205.941 uV, v_off_fin = 2226.299 uV 14:32:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.875 uVs 14:32:17 I1X Average and RMS of Measurements VT = -64.673 +- 14.387 uVs I1X = 12.935 +- 2.877 uTm 14:32:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:32:24 Integrated Voltage Measurement... 14:32:33 Voltage Offset Correction: v_off_ini = 2205.347 uV, v_off_fin = 2206.134 uV 14:32:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.540 uVs 14:32:33 Integrated Voltage Measurement... 14:32:42 Voltage Offset Correction: v_off_ini = 2212.304 uV, v_off_fin = 2211.693 uV 14:32:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.807 uVs 14:32:42 Integrated Voltage Measurement... 14:32:51 Voltage Offset Correction: v_off_ini = 2212.812 uV, v_off_fin = 2208.452 uV 14:32:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.885 uVs 14:32:51 Integrated Voltage Measurement... 14:33:00 Voltage Offset Correction: v_off_ini = 2212.537 uV, v_off_fin = 2215.056 uV 14:33:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 179.445 uVs 14:33:00 Integrated Voltage Measurement... 14:33:09 Voltage Offset Correction: v_off_ini = 2252.933 uV, v_off_fin = 2243.626 uV 14:33:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.880 uVs 14:33:09 Integrated Voltage Measurement... 14:33:18 Voltage Offset Correction: v_off_ini = 2237.127 uV, v_off_fin = 2242.875 uV 14:33:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 171.850 uVs 14:33:22 I1Y Average and RMS of Measurements VT = -182.401 +- 3.069 uVs I1Y = -36.477 +- 0.612 uTm 14:33:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:33:30 Integrated Voltage Measurement... 14:33:39 Voltage Offset Correction: v_off_ini = 2227.365 uV, v_off_fin = 2222.840 uV 14:33:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.175 uVs 14:33:39 Integrated Voltage Measurement... 14:33:48 Voltage Offset Correction: v_off_ini = 2240.059 uV, v_off_fin = 2259.515 uV 14:33:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.470 uVs 14:33:48 Integrated Voltage Measurement... 14:33:57 Voltage Offset Correction: v_off_ini = 2244.742 uV, v_off_fin = 2218.954 uV 14:33:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.547 uVs 14:33:57 Integrated Voltage Measurement... 14:34:06 Voltage Offset Correction: v_off_ini = 2209.933 uV, v_off_fin = 2248.219 uV 14:34:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.640 uVs 14:34:06 Integrated Voltage Measurement... 14:34:15 Voltage Offset Correction: v_off_ini = 2211.783 uV, v_off_fin = 2218.400 uV 14:34:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.011 uVs 14:34:15 Integrated Voltage Measurement... 14:34:24 Voltage Offset Correction: v_off_ini = 2213.698 uV, v_off_fin = 2223.649 uV 14:34:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.823 uVs 14:34:26 I2X Average and RMS of Measurements VT = -61.611 +- 5.687 uVs I2X = 5.668 +- 0.523 uTm^2 14:34:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:34:34 Integrated Voltage Measurement... 14:34:43 Voltage Offset Correction: v_off_ini = 2227.611 uV, v_off_fin = 2206.791 uV 14:34:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.433 uVs 14:34:43 Integrated Voltage Measurement... 14:34:52 Voltage Offset Correction: v_off_ini = 2220.625 uV, v_off_fin = 2192.028 uV 14:34:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.345 uVs 14:34:52 Integrated Voltage Measurement... 14:35:01 Voltage Offset Correction: v_off_ini = 2224.420 uV, v_off_fin = 2235.145 uV 14:35:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.175 uVs 14:35:01 Integrated Voltage Measurement... 14:35:10 Voltage Offset Correction: v_off_ini = 2213.951 uV, v_off_fin = 2208.826 uV 14:35:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.050 uVs 14:35:10 Integrated Voltage Measurement... 14:35:19 Voltage Offset Correction: v_off_ini = 2208.723 uV, v_off_fin = 2225.241 uV 14:35:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.089 uVs 14:35:19 Integrated Voltage Measurement... 14:35:28 Voltage Offset Correction: v_off_ini = 2243.177 uV, v_off_fin = 2247.926 uV 14:35:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.575 uVs 14:35:31 I2Y Average and RMS of Measurements VT = -244.778 +- 5.603 uVs I2Y = -22.520 +- 0.515 uTm^2 14:35:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:35:49 Integrated Voltage Measurement... 14:35:58 Voltage Offset Correction: v_off_ini = 2237.277 uV, v_off_fin = 2213.786 uV 14:35:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.407 uVs 14:35:58 Integrated Voltage Measurement... 14:36:07 Voltage Offset Correction: v_off_ini = 2204.365 uV, v_off_fin = 2228.732 uV 14:36:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.760 uVs 14:36:07 Integrated Voltage Measurement... 14:36:16 Voltage Offset Correction: v_off_ini = 2235.040 uV, v_off_fin = 2238.364 uV 14:36:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.947 uVs 14:36:16 Integrated Voltage Measurement... 14:36:25 Voltage Offset Correction: v_off_ini = 2207.185 uV, v_off_fin = 2256.764 uV 14:36:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 19.991 uVs 14:36:25 Integrated Voltage Measurement... 14:36:34 Voltage Offset Correction: v_off_ini = 2236.438 uV, v_off_fin = 2237.919 uV 14:36:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.883 uVs 14:36:34 Integrated Voltage Measurement... 14:36:43 Voltage Offset Correction: v_off_ini = 2240.308 uV, v_off_fin = 2231.862 uV 14:36:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.367 uVs 14:36:47 I1X Average and RMS of Measurements VT = -53.226 +- 18.054 uVs I1X = 10.645 +- 3.611 uTm 14:36:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:36:54 Integrated Voltage Measurement... 14:37:03 Voltage Offset Correction: v_off_ini = 2230.122 uV, v_off_fin = 2217.209 uV 14:37:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.784 uVs 14:37:03 Integrated Voltage Measurement... 14:37:12 Voltage Offset Correction: v_off_ini = 2249.840 uV, v_off_fin = 2237.371 uV 14:37:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.397 uVs 14:37:12 Integrated Voltage Measurement... 14:37:21 Voltage Offset Correction: v_off_ini = 2249.898 uV, v_off_fin = 2235.981 uV 14:37:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.065 uVs 14:37:21 Integrated Voltage Measurement... 14:37:30 Voltage Offset Correction: v_off_ini = 2238.418 uV, v_off_fin = 2249.381 uV 14:37:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.750 uVs 14:37:30 Integrated Voltage Measurement... 14:37:39 Voltage Offset Correction: v_off_ini = 2202.061 uV, v_off_fin = 2226.280 uV 14:37:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.518 uVs 14:37:39 Integrated Voltage Measurement... 14:37:48 Voltage Offset Correction: v_off_ini = 2254.740 uV, v_off_fin = 2247.045 uV 14:37:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.889 uVs 14:37:52 I1Y Average and RMS of Measurements VT = -190.067 +- 12.473 uVs I1Y = -38.011 +- 2.493 uTm 14:37:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:38:00 Integrated Voltage Measurement... 14:38:09 Voltage Offset Correction: v_off_ini = 2232.814 uV, v_off_fin = 2256.509 uV 14:38:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -22.858 uVs 14:38:09 Integrated Voltage Measurement... 14:38:18 Voltage Offset Correction: v_off_ini = 2222.880 uV, v_off_fin = 2246.666 uV 14:38:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.003 uVs 14:38:18 Integrated Voltage Measurement... 14:38:27 Voltage Offset Correction: v_off_ini = 2233.136 uV, v_off_fin = 2219.915 uV 14:38:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.589 uVs 14:38:27 Integrated Voltage Measurement... 14:38:36 Voltage Offset Correction: v_off_ini = 2256.563 uV, v_off_fin = 2260.540 uV 14:38:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.795 uVs 14:38:36 Integrated Voltage Measurement... 14:38:45 Voltage Offset Correction: v_off_ini = 2256.181 uV, v_off_fin = 2242.430 uV 14:38:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -30.609 uVs 14:38:45 Integrated Voltage Measurement... 14:38:54 Voltage Offset Correction: v_off_ini = 2270.725 uV, v_off_fin = 2290.133 uV 14:38:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.340 uVs 14:38:56 I2X Average and RMS of Measurements VT = -40.366 +- 11.854 uVs I2X = 3.714 +- 1.091 uTm^2 14:39:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:04 Integrated Voltage Measurement... 14:39:13 Voltage Offset Correction: v_off_ini = 2235.802 uV, v_off_fin = 2247.523 uV 14:39:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.629 uVs 14:39:13 Integrated Voltage Measurement... 14:39:22 Voltage Offset Correction: v_off_ini = 2273.723 uV, v_off_fin = 2253.800 uV 14:39:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.439 uVs 14:39:22 Integrated Voltage Measurement... 14:39:31 Voltage Offset Correction: v_off_ini = 2300.160 uV, v_off_fin = 2288.239 uV 14:39:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.723 uVs 14:39:31 Integrated Voltage Measurement... 14:39:40 Voltage Offset Correction: v_off_ini = 2282.261 uV, v_off_fin = 2287.239 uV 14:39:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.952 uVs 14:39:40 Integrated Voltage Measurement... 14:39:49 Voltage Offset Correction: v_off_ini = 2311.169 uV, v_off_fin = 2290.516 uV 14:39:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.637 uVs 14:39:49 Integrated Voltage Measurement... 14:39:58 Voltage Offset Correction: v_off_ini = 2305.845 uV, v_off_fin = 2265.697 uV 14:39:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.022 uVs 14:40:01 I2Y Average and RMS of Measurements VT = -241.567 +- 16.046 uVs I2Y = -22.224 +- 1.476 uTm^2 14:40:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:19 Integrated Voltage Measurement... 14:40:28 Voltage Offset Correction: v_off_ini = 2301.989 uV, v_off_fin = 2291.132 uV 14:40:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.274 uVs 14:40:28 Integrated Voltage Measurement... 14:40:37 Voltage Offset Correction: v_off_ini = 2314.557 uV, v_off_fin = 2308.835 uV 14:40:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.838 uVs 14:40:37 Integrated Voltage Measurement... 14:40:46 Voltage Offset Correction: v_off_ini = 2269.482 uV, v_off_fin = 2285.156 uV 14:40:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -15.908 uVs 14:40:46 Integrated Voltage Measurement... 14:40:55 Voltage Offset Correction: v_off_ini = 2313.823 uV, v_off_fin = 2310.457 uV 14:40:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 40.124 uVs 14:40:55 Integrated Voltage Measurement... 14:41:04 Voltage Offset Correction: v_off_ini = 2320.700 uV, v_off_fin = 2284.920 uV 14:41:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.932 uVs 14:41:04 Integrated Voltage Measurement... 14:41:13 Voltage Offset Correction: v_off_ini = 2292.261 uV, v_off_fin = 2310.629 uV 14:41:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.122 uVs 14:41:17 I1X Average and RMS of Measurements VT = -57.366 +- 20.771 uVs I1X = 11.474 +- 4.154 uTm 14:41:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:24 Integrated Voltage Measurement... 14:41:33 Voltage Offset Correction: v_off_ini = 2314.589 uV, v_off_fin = 2302.761 uV 14:41:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.959 uVs 14:41:33 Integrated Voltage Measurement... 14:41:42 Voltage Offset Correction: v_off_ini = 2306.225 uV, v_off_fin = 2314.642 uV 14:41:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.935 uVs 14:41:42 Integrated Voltage Measurement... 14:41:51 Voltage Offset Correction: v_off_ini = 2305.596 uV, v_off_fin = 2290.097 uV 14:41:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.181 uVs 14:41:51 Integrated Voltage Measurement... 14:42:00 Voltage Offset Correction: v_off_ini = 2314.532 uV, v_off_fin = 2327.723 uV 14:42:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.348 uVs 14:42:00 Integrated Voltage Measurement... 14:42:09 Voltage Offset Correction: v_off_ini = 2291.046 uV, v_off_fin = 2286.160 uV 14:42:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.854 uVs 14:42:09 Integrated Voltage Measurement... 14:42:18 Voltage Offset Correction: v_off_ini = 2329.455 uV, v_off_fin = 2343.318 uV 14:42:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.921 uVs 14:42:22 I1Y Average and RMS of Measurements VT = -195.533 +- 3.954 uVs I1Y = -39.103 +- 0.791 uTm 14:42:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:30 Integrated Voltage Measurement... 14:42:39 Voltage Offset Correction: v_off_ini = 2323.241 uV, v_off_fin = 2311.943 uV 14:42:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -75.901 uVs 14:42:39 Integrated Voltage Measurement... 14:42:48 Voltage Offset Correction: v_off_ini = 2334.548 uV, v_off_fin = 2301.949 uV 14:42:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.242 uVs 14:42:48 Integrated Voltage Measurement... 14:42:57 Voltage Offset Correction: v_off_ini = 2346.254 uV, v_off_fin = 2319.860 uV 14:42:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -32.172 uVs 14:42:57 Integrated Voltage Measurement... 14:43:06 Voltage Offset Correction: v_off_ini = 2334.556 uV, v_off_fin = 2340.418 uV 14:43:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.715 uVs 14:43:06 Integrated Voltage Measurement... 14:43:15 Voltage Offset Correction: v_off_ini = 2307.426 uV, v_off_fin = 2310.655 uV 14:43:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.858 uVs 14:43:15 Integrated Voltage Measurement... 14:43:24 Voltage Offset Correction: v_off_ini = 2337.574 uV, v_off_fin = 2322.587 uV 14:43:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.442 uVs 14:43:26 I2X Average and RMS of Measurements VT = -49.888 +- 6.442 uVs I2X = 4.590 +- 0.593 uTm^2 14:43:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:34 Integrated Voltage Measurement... 14:43:43 Voltage Offset Correction: v_off_ini = 2299.903 uV, v_off_fin = 2330.206 uV 14:43:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.508 uVs 14:43:43 Integrated Voltage Measurement... 14:43:52 Voltage Offset Correction: v_off_ini = 2338.895 uV, v_off_fin = 2372.280 uV 14:43:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.766 uVs 14:43:52 Integrated Voltage Measurement... 14:44:01 Voltage Offset Correction: v_off_ini = 2359.170 uV, v_off_fin = 2332.290 uV 14:44:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.808 uVs 14:44:01 Integrated Voltage Measurement... 14:44:10 Voltage Offset Correction: v_off_ini = 2338.622 uV, v_off_fin = 2332.495 uV 14:44:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.666 uVs 14:44:10 Integrated Voltage Measurement... 14:44:19 Voltage Offset Correction: v_off_ini = 2319.548 uV, v_off_fin = 2311.298 uV 14:44:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.112 uVs 14:44:19 Integrated Voltage Measurement... 14:44:28 Voltage Offset Correction: v_off_ini = 2318.122 uV, v_off_fin = 2322.309 uV 14:44:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.605 uVs 14:44:31 I2Y Average and RMS of Measurements VT = -235.078 +- 4.276 uVs I2Y = -21.627 +- 0.393 uTm^2