SLAC Magnetic Measurements Date: 07-31-2026 Time: 14:44:55 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16334 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 4 Measurement Device: Stretched Wire Operator: YL Comment: 14:45:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:45:05 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:45:07 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:45:08 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:45:10 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:45:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:45:52 Integrated Voltage Measurement... 14:46:01 Voltage Offset Correction: v_off_ini = 2317.003 uV, v_off_fin = 2299.228 uV 14:46:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -133.542 uVs 14:46:01 Integrated Voltage Measurement... 14:46:10 Voltage Offset Correction: v_off_ini = 2297.804 uV, v_off_fin = 2331.967 uV 14:46:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.176 uVs 14:46:10 Integrated Voltage Measurement... 14:46:19 Voltage Offset Correction: v_off_ini = 2311.672 uV, v_off_fin = 2339.248 uV 14:46:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.892 uVs 14:46:19 Integrated Voltage Measurement... 14:46:28 Voltage Offset Correction: v_off_ini = 2327.803 uV, v_off_fin = 2345.240 uV 14:46:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 96.031 uVs 14:46:28 Integrated Voltage Measurement... 14:46:37 Voltage Offset Correction: v_off_ini = 2335.659 uV, v_off_fin = 2319.234 uV 14:46:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.664 uVs 14:46:37 Integrated Voltage Measurement... 14:46:46 Voltage Offset Correction: v_off_ini = 2337.184 uV, v_off_fin = 2339.856 uV 14:46:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.731 uVs 14:46:50 I1X Average and RMS of Measurements VT = -107.173 +- 14.397 uVs I1X = 21.436 +- 2.878 uTm 14:46:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:46:57 Integrated Voltage Measurement... 14:47:06 Voltage Offset Correction: v_off_ini = 2370.484 uV, v_off_fin = 2354.136 uV 14:47:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.339 uVs 14:47:06 Integrated Voltage Measurement... 14:47:15 Voltage Offset Correction: v_off_ini = 2344.638 uV, v_off_fin = 2344.500 uV 14:47:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.185 uVs 14:47:15 Integrated Voltage Measurement... 14:47:24 Voltage Offset Correction: v_off_ini = 2348.449 uV, v_off_fin = 2357.922 uV 14:47:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.935 uVs 14:47:24 Integrated Voltage Measurement... 14:47:33 Voltage Offset Correction: v_off_ini = 2355.769 uV, v_off_fin = 2336.559 uV 14:47:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.948 uVs 14:47:33 Integrated Voltage Measurement... 14:47:42 Voltage Offset Correction: v_off_ini = 2351.201 uV, v_off_fin = 2326.724 uV 14:47:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.689 uVs 14:47:42 Integrated Voltage Measurement... 14:47:51 Voltage Offset Correction: v_off_ini = 2359.296 uV, v_off_fin = 2345.238 uV 14:47:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.545 uVs 14:47:55 I1Y Average and RMS of Measurements VT = -226.773 +- 4.254 uVs I1Y = -45.355 +- 0.851 uTm 14:48:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:48:03 Integrated Voltage Measurement... 14:48:12 Voltage Offset Correction: v_off_ini = 2333.000 uV, v_off_fin = 2356.412 uV 14:48:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.895 uVs 14:48:12 Integrated Voltage Measurement... 14:48:21 Voltage Offset Correction: v_off_ini = 2397.777 uV, v_off_fin = 2376.125 uV 14:48:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.067 uVs 14:48:21 Integrated Voltage Measurement... 14:48:30 Voltage Offset Correction: v_off_ini = 2364.996 uV, v_off_fin = 2374.577 uV 14:48:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -129.479 uVs 14:48:30 Integrated Voltage Measurement... 14:48:39 Voltage Offset Correction: v_off_ini = 2369.251 uV, v_off_fin = 2374.791 uV 14:48:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 136.897 uVs 14:48:39 Integrated Voltage Measurement... 14:48:48 Voltage Offset Correction: v_off_ini = 2371.796 uV, v_off_fin = 2359.076 uV 14:48:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.682 uVs 14:48:48 Integrated Voltage Measurement... 14:48:57 Voltage Offset Correction: v_off_ini = 2386.747 uV, v_off_fin = 2375.665 uV 14:48:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.593 uVs 14:48:59 I2X Average and RMS of Measurements VT = -115.102 +- 23.346 uVs I2X = 10.590 +- 2.148 uTm^2 14:49:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:49:07 Integrated Voltage Measurement... 14:49:16 Voltage Offset Correction: v_off_ini = 2382.856 uV, v_off_fin = 2389.587 uV 14:49:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.027 uVs 14:49:16 Integrated Voltage Measurement... 14:49:25 Voltage Offset Correction: v_off_ini = 2404.839 uV, v_off_fin = 2406.464 uV 14:49:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.437 uVs 14:49:25 Integrated Voltage Measurement... 14:49:34 Voltage Offset Correction: v_off_ini = 2398.403 uV, v_off_fin = 2424.108 uV 14:49:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.266 uVs 14:49:34 Integrated Voltage Measurement... 14:49:43 Voltage Offset Correction: v_off_ini = 2427.811 uV, v_off_fin = 2411.316 uV 14:49:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.235 uVs 14:49:43 Integrated Voltage Measurement... 14:49:52 Voltage Offset Correction: v_off_ini = 2366.351 uV, v_off_fin = 2379.830 uV 14:49:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.574 uVs 14:49:52 Integrated Voltage Measurement... 14:50:01 Voltage Offset Correction: v_off_ini = 2434.056 uV, v_off_fin = 2403.204 uV 14:50:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.498 uVs 14:50:04 I2Y Average and RMS of Measurements VT = -359.506 +- 3.263 uVs I2Y = -33.075 +- 0.300 uTm^2 14:50:08 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:50:12 Integrated Voltage Measurement... 14:50:21 Voltage Offset Correction: v_off_ini = 2375.972 uV, v_off_fin = 2376.696 uV 14:50:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.938 uVs 14:50:21 Integrated Voltage Measurement... 14:50:30 Voltage Offset Correction: v_off_ini = 2403.519 uV, v_off_fin = 2399.577 uV 14:50:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.997 uVs 14:50:30 Integrated Voltage Measurement... 14:50:39 Voltage Offset Correction: v_off_ini = 2406.478 uV, v_off_fin = 2399.166 uV 14:50:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.270 uVs 14:50:39 Integrated Voltage Measurement... 14:50:48 Voltage Offset Correction: v_off_ini = 2382.028 uV, v_off_fin = 2394.628 uV 14:50:48 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.745 uVs 14:50:48 Integrated Voltage Measurement... 14:50:57 Voltage Offset Correction: v_off_ini = 2401.335 uV, v_off_fin = 2408.153 uV 14:50:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.716 uVs 14:50:57 Integrated Voltage Measurement... 14:51:06 Voltage Offset Correction: v_off_ini = 2406.282 uV, v_off_fin = 2393.188 uV 14:51:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.239 uVs 14:51:11 I1X Average and RMS of Measurements VT = -116.484 +- 4.259 uVs I1X = 23.297 +- 0.852 uTm 14:51:13 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:51:17 Integrated Voltage Measurement... 14:51:26 Voltage Offset Correction: v_off_ini = 2409.536 uV, v_off_fin = 2420.120 uV 14:51:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.696 uVs 14:51:26 Integrated Voltage Measurement... 14:51:35 Voltage Offset Correction: v_off_ini = 2409.974 uV, v_off_fin = 2446.066 uV 14:51:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.559 uVs 14:51:35 Integrated Voltage Measurement... 14:51:44 Voltage Offset Correction: v_off_ini = 2425.695 uV, v_off_fin = 2383.106 uV 14:51:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.809 uVs 14:51:44 Integrated Voltage Measurement... 14:51:53 Voltage Offset Correction: v_off_ini = 2401.785 uV, v_off_fin = 2393.546 uV 14:51:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.840 uVs 14:51:53 Integrated Voltage Measurement... 14:52:02 Voltage Offset Correction: v_off_ini = 2401.008 uV, v_off_fin = 2402.520 uV 14:52:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.642 uVs 14:52:02 Integrated Voltage Measurement... 14:52:11 Voltage Offset Correction: v_off_ini = 2394.108 uV, v_off_fin = 2417.367 uV 14:52:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.085 uVs 14:52:15 I1Y Average and RMS of Measurements VT = -228.105 +- 13.750 uVs I1Y = -45.621 +- 2.750 uTm 14:52:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:52:23 Integrated Voltage Measurement... 14:52:32 Voltage Offset Correction: v_off_ini = 2407.215 uV, v_off_fin = 2428.434 uV 14:52:32 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -123.611 uVs 14:52:32 Integrated Voltage Measurement... 14:52:41 Voltage Offset Correction: v_off_ini = 2443.215 uV, v_off_fin = 2437.794 uV 14:52:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.283 uVs 14:52:41 Integrated Voltage Measurement... 14:52:50 Voltage Offset Correction: v_off_ini = 2388.677 uV, v_off_fin = 2379.670 uV 14:52:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.779 uVs 14:52:50 Integrated Voltage Measurement... 14:52:59 Voltage Offset Correction: v_off_ini = 2409.363 uV, v_off_fin = 2441.241 uV 14:52:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.503 uVs 14:52:59 Integrated Voltage Measurement... 14:53:08 Voltage Offset Correction: v_off_ini = 2430.319 uV, v_off_fin = 2419.024 uV 14:53:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -128.072 uVs 14:53:08 Integrated Voltage Measurement... 14:53:17 Voltage Offset Correction: v_off_ini = 2413.199 uV, v_off_fin = 2435.635 uV 14:53:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.987 uVs 14:53:20 I2X Average and RMS of Measurements VT = -117.372 +- 5.249 uVs I2X = 10.799 +- 0.484 uTm^2 14:53:25 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:53:27 Integrated Voltage Measurement... 14:53:36 Voltage Offset Correction: v_off_ini = 2448.256 uV, v_off_fin = 2434.090 uV 14:53:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -425.441 uVs 14:53:36 Integrated Voltage Measurement... 14:53:45 Voltage Offset Correction: v_off_ini = 2413.768 uV, v_off_fin = 2437.244 uV 14:53:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 395.045 uVs 14:53:45 Integrated Voltage Measurement... 14:53:54 Voltage Offset Correction: v_off_ini = 2419.053 uV, v_off_fin = 2439.542 uV 14:53:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -385.407 uVs 14:53:54 Integrated Voltage Measurement... 14:54:03 Voltage Offset Correction: v_off_ini = 2431.334 uV, v_off_fin = 2439.738 uV 14:54:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 388.810 uVs 14:54:03 Integrated Voltage Measurement... 14:54:12 Voltage Offset Correction: v_off_ini = 2455.369 uV, v_off_fin = 2450.940 uV 14:54:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -381.391 uVs 14:54:12 Integrated Voltage Measurement... 14:54:21 Voltage Offset Correction: v_off_ini = 2447.809 uV, v_off_fin = 2468.586 uV 14:54:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.665 uVs 14:54:24 I2Y Average and RMS of Measurements VT = -394.293 +- 11.297 uVs I2Y = -36.275 +- 1.039 uTm^2 14:54:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:33 Integrated Voltage Measurement... 14:54:42 Voltage Offset Correction: v_off_ini = 2457.368 uV, v_off_fin = 2446.203 uV 14:54:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.423 uVs 14:54:42 Integrated Voltage Measurement... 14:54:51 Voltage Offset Correction: v_off_ini = 2453.422 uV, v_off_fin = 2476.740 uV 14:54:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.641 uVs 14:54:51 Integrated Voltage Measurement... 14:55:00 Voltage Offset Correction: v_off_ini = 2482.307 uV, v_off_fin = 2492.589 uV 14:55:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.764 uVs 14:55:00 Integrated Voltage Measurement... 14:55:09 Voltage Offset Correction: v_off_ini = 2469.073 uV, v_off_fin = 2478.711 uV 14:55:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.050 uVs 14:55:09 Integrated Voltage Measurement... 14:55:18 Voltage Offset Correction: v_off_ini = 2472.455 uV, v_off_fin = 2452.991 uV 14:55:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.397 uVs 14:55:18 Integrated Voltage Measurement... 14:55:27 Voltage Offset Correction: v_off_ini = 2475.556 uV, v_off_fin = 2498.257 uV 14:55:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.769 uVs 14:55:31 I1X Average and RMS of Measurements VT = -117.174 +- 9.391 uVs I1X = 23.435 +- 1.878 uTm 14:55:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:38 Integrated Voltage Measurement... 14:55:46 Voltage Offset Correction: v_off_ini = 2473.565 uV, v_off_fin = 2486.996 uV 14:55:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.500 uVs 14:55:47 Integrated Voltage Measurement... 14:55:55 Voltage Offset Correction: v_off_ini = 2485.535 uV, v_off_fin = 2497.682 uV 14:55:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.424 uVs 14:55:56 Integrated Voltage Measurement... 14:56:04 Voltage Offset Correction: v_off_ini = 2472.759 uV, v_off_fin = 2468.285 uV 14:56:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.964 uVs 14:56:05 Integrated Voltage Measurement... 14:56:13 Voltage Offset Correction: v_off_ini = 2469.312 uV, v_off_fin = 2495.102 uV 14:56:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.144 uVs 14:56:14 Integrated Voltage Measurement... 14:56:22 Voltage Offset Correction: v_off_ini = 2490.416 uV, v_off_fin = 2499.910 uV 14:56:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.775 uVs 14:56:23 Integrated Voltage Measurement... 14:56:31 Voltage Offset Correction: v_off_ini = 2507.377 uV, v_off_fin = 2515.333 uV 14:56:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.774 uVs 14:56:36 I1Y Average and RMS of Measurements VT = -253.763 +- 7.487 uVs I1Y = -50.754 +- 1.496 uTm 14:56:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:43 Integrated Voltage Measurement... 14:56:52 Voltage Offset Correction: v_off_ini = 2492.913 uV, v_off_fin = 2461.846 uV 14:56:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -102.911 uVs 14:56:52 Integrated Voltage Measurement... 14:57:01 Voltage Offset Correction: v_off_ini = 2540.619 uV, v_off_fin = 2532.930 uV 14:57:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.349 uVs 14:57:01 Integrated Voltage Measurement... 14:57:10 Voltage Offset Correction: v_off_ini = 2501.560 uV, v_off_fin = 2505.251 uV 14:57:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.362 uVs 14:57:10 Integrated Voltage Measurement... 14:57:19 Voltage Offset Correction: v_off_ini = 2509.238 uV, v_off_fin = 2507.654 uV 14:57:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.021 uVs 14:57:19 Integrated Voltage Measurement... 14:57:28 Voltage Offset Correction: v_off_ini = 2512.611 uV, v_off_fin = 2477.510 uV 14:57:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.658 uVs 14:57:28 Integrated Voltage Measurement... 14:57:37 Voltage Offset Correction: v_off_ini = 2482.228 uV, v_off_fin = 2508.923 uV 14:57:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.252 uVs 14:57:40 I2X Average and RMS of Measurements VT = -115.592 +- 13.681 uVs I2X = 10.635 +- 1.259 uTm^2 14:57:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:48 Integrated Voltage Measurement... 14:57:57 Voltage Offset Correction: v_off_ini = 2486.494 uV, v_off_fin = 2488.299 uV 14:57:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -391.047 uVs 14:57:57 Integrated Voltage Measurement... 14:58:06 Voltage Offset Correction: v_off_ini = 2478.287 uV, v_off_fin = 2466.416 uV 14:58:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 404.084 uVs 14:58:06 Integrated Voltage Measurement... 14:58:15 Voltage Offset Correction: v_off_ini = 2490.824 uV, v_off_fin = 2472.486 uV 14:58:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -415.405 uVs 14:58:15 Integrated Voltage Measurement... 14:58:24 Voltage Offset Correction: v_off_ini = 2494.284 uV, v_off_fin = 2472.628 uV 14:58:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 390.559 uVs 14:58:24 Integrated Voltage Measurement... 14:58:33 Voltage Offset Correction: v_off_ini = 2478.398 uV, v_off_fin = 2476.393 uV 14:58:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.387 uVs 14:58:33 Integrated Voltage Measurement... 14:58:42 Voltage Offset Correction: v_off_ini = 2481.082 uV, v_off_fin = 2471.842 uV 14:58:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.218 uVs 14:58:44 I2Y Average and RMS of Measurements VT = -395.117 +- 7.621 uVs I2Y = -36.351 +- 0.701 uTm^2 14:58:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:58:53 Integrated Voltage Measurement... 14:59:02 Voltage Offset Correction: v_off_ini = 2474.089 uV, v_off_fin = 2469.435 uV 14:59:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -137.396 uVs 14:59:02 Integrated Voltage Measurement... 14:59:11 Voltage Offset Correction: v_off_ini = 2479.239 uV, v_off_fin = 2462.286 uV 14:59:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.044 uVs 14:59:11 Integrated Voltage Measurement... 14:59:20 Voltage Offset Correction: v_off_ini = 2479.896 uV, v_off_fin = 2483.795 uV 14:59:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -200.143 uVs 14:59:20 Integrated Voltage Measurement... 14:59:29 Voltage Offset Correction: v_off_ini = 2499.403 uV, v_off_fin = 2507.650 uV 14:59:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.251 uVs 14:59:29 Integrated Voltage Measurement... 14:59:38 Voltage Offset Correction: v_off_ini = 2480.629 uV, v_off_fin = 2472.479 uV 14:59:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.655 uVs 14:59:38 Integrated Voltage Measurement... 14:59:47 Voltage Offset Correction: v_off_ini = 2486.570 uV, v_off_fin = 2498.023 uV 14:59:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.608 uVs 14:59:51 I1X Average and RMS of Measurements VT = -131.183 +- 38.393 uVs I1X = 26.237 +- 7.678 uTm 14:59:54 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:59:58 Integrated Voltage Measurement... 15:00:07 Voltage Offset Correction: v_off_ini = 2490.812 uV, v_off_fin = 2471.045 uV 15:00:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -347.406 uVs 15:00:07 Integrated Voltage Measurement... 15:00:16 Voltage Offset Correction: v_off_ini = 2527.219 uV, v_off_fin = 2534.921 uV 15:00:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.806 uVs 15:00:16 Integrated Voltage Measurement... 15:00:25 Voltage Offset Correction: v_off_ini = 2511.779 uV, v_off_fin = 2500.177 uV 15:00:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.712 uVs 15:00:25 Integrated Voltage Measurement... 15:00:34 Voltage Offset Correction: v_off_ini = 2496.187 uV, v_off_fin = 2488.730 uV 15:00:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.656 uVs 15:00:34 Integrated Voltage Measurement... 15:00:43 Voltage Offset Correction: v_off_ini = 2507.892 uV, v_off_fin = 2496.880 uV 15:00:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.303 uVs 15:00:43 Integrated Voltage Measurement... 15:00:52 Voltage Offset Correction: v_off_ini = 2520.543 uV, v_off_fin = 2513.774 uV 15:00:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.408 uVs 15:00:56 I1Y Average and RMS of Measurements VT = -271.048 +- 26.559 uVs I1Y = -54.211 +- 5.314 uTm 15:01:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:01:04 Integrated Voltage Measurement... 15:01:13 Voltage Offset Correction: v_off_ini = 2528.549 uV, v_off_fin = 2533.267 uV 15:01:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -139.880 uVs 15:01:13 Integrated Voltage Measurement... 15:01:22 Voltage Offset Correction: v_off_ini = 2512.681 uV, v_off_fin = 2514.960 uV 15:01:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.285 uVs 15:01:22 Integrated Voltage Measurement... 15:01:31 Voltage Offset Correction: v_off_ini = 2499.609 uV, v_off_fin = 2521.769 uV 15:01:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -170.845 uVs 15:01:31 Integrated Voltage Measurement... 15:01:40 Voltage Offset Correction: v_off_ini = 2498.008 uV, v_off_fin = 2492.273 uV 15:01:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 130.908 uVs 15:01:40 Integrated Voltage Measurement... 15:01:49 Voltage Offset Correction: v_off_ini = 2506.989 uV, v_off_fin = 2521.165 uV 15:01:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -144.498 uVs 15:01:49 Integrated Voltage Measurement... 15:01:58 Voltage Offset Correction: v_off_ini = 2553.875 uV, v_off_fin = 2545.458 uV 15:01:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 133.638 uVs 15:02:00 I2X Average and RMS of Measurements VT = -138.509 +- 10.334 uVs I2X = 12.744 +- 0.951 uTm^2 15:02:05 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:02:08 Integrated Voltage Measurement... 15:02:17 Voltage Offset Correction: v_off_ini = 2524.278 uV, v_off_fin = 2525.346 uV 15:02:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -403.939 uVs 15:02:17 Integrated Voltage Measurement... 15:02:26 Voltage Offset Correction: v_off_ini = 2519.315 uV, v_off_fin = 2523.768 uV 15:02:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 412.488 uVs 15:02:26 Integrated Voltage Measurement... 15:02:35 Voltage Offset Correction: v_off_ini = 2537.611 uV, v_off_fin = 2540.447 uV 15:02:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -428.607 uVs 15:02:35 Integrated Voltage Measurement... 15:02:44 Voltage Offset Correction: v_off_ini = 2522.702 uV, v_off_fin = 2541.203 uV 15:02:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 395.830 uVs 15:02:44 Integrated Voltage Measurement... 15:02:53 Voltage Offset Correction: v_off_ini = 2521.440 uV, v_off_fin = 2500.442 uV 15:02:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -409.923 uVs 15:02:53 Integrated Voltage Measurement... 15:03:02 Voltage Offset Correction: v_off_ini = 2534.426 uV, v_off_fin = 2565.322 uV 15:03:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 381.219 uVs 15:03:05 I2Y Average and RMS of Measurements VT = -405.334 +- 7.095 uVs I2Y = -37.291 +- 0.653 uTm^2 15:03:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:03:13 Integrated Voltage Measurement... 15:03:22 Voltage Offset Correction: v_off_ini = 2517.914 uV, v_off_fin = 2557.032 uV 15:03:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -133.659 uVs 15:03:22 Integrated Voltage Measurement... 15:03:31 Voltage Offset Correction: v_off_ini = 2500.352 uV, v_off_fin = 2537.276 uV 15:03:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.817 uVs 15:03:31 Integrated Voltage Measurement... 15:03:40 Voltage Offset Correction: v_off_ini = 2552.329 uV, v_off_fin = 2545.418 uV 15:03:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.156 uVs 15:03:40 Integrated Voltage Measurement... 15:03:49 Voltage Offset Correction: v_off_ini = 2564.886 uV, v_off_fin = 2538.473 uV 15:03:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.812 uVs 15:03:49 Integrated Voltage Measurement... 15:03:58 Voltage Offset Correction: v_off_ini = 2546.332 uV, v_off_fin = 2571.791 uV 15:03:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.319 uVs 15:03:58 Integrated Voltage Measurement... 15:04:07 Voltage Offset Correction: v_off_ini = 2564.013 uV, v_off_fin = 2538.082 uV 15:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.081 uVs 15:04:12 I1X Average and RMS of Measurements VT = -128.141 +- 20.842 uVs I1X = 25.629 +- 4.170 uTm 15:04:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:04:18 Integrated Voltage Measurement... 15:04:27 Voltage Offset Correction: v_off_ini = 2544.667 uV, v_off_fin = 2514.969 uV 15:04:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.650 uVs 15:04:27 Integrated Voltage Measurement... 15:04:36 Voltage Offset Correction: v_off_ini = 2527.230 uV, v_off_fin = 2511.150 uV 15:04:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.469 uVs 15:04:36 Integrated Voltage Measurement... 15:04:45 Voltage Offset Correction: v_off_ini = 2535.830 uV, v_off_fin = 2559.634 uV 15:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.900 uVs 15:04:45 Integrated Voltage Measurement... 15:04:54 Voltage Offset Correction: v_off_ini = 2547.166 uV, v_off_fin = 2606.055 uV 15:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.155 uVs 15:04:54 Integrated Voltage Measurement... 15:05:03 Voltage Offset Correction: v_off_ini = 2560.205 uV, v_off_fin = 2547.726 uV 15:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.818 uVs 15:05:03 Integrated Voltage Measurement... 15:05:12 Voltage Offset Correction: v_off_ini = 2544.152 uV, v_off_fin = 2539.837 uV 15:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.178 uVs 15:05:17 I1Y Average and RMS of Measurements VT = -272.362 +- 5.127 uVs I1Y = -54.472 +- 1.025 uTm 15:05:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:05:24 Integrated Voltage Measurement... 15:05:33 Voltage Offset Correction: v_off_ini = 2504.106 uV, v_off_fin = 2501.727 uV 15:05:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.399 uVs 15:05:33 Integrated Voltage Measurement... 15:05:42 Voltage Offset Correction: v_off_ini = 2488.059 uV, v_off_fin = 2528.107 uV 15:05:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 129.074 uVs 15:05:42 Integrated Voltage Measurement... 15:05:51 Voltage Offset Correction: v_off_ini = 2520.792 uV, v_off_fin = 2510.638 uV 15:05:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.572 uVs 15:05:51 Integrated Voltage Measurement... 15:06:00 Voltage Offset Correction: v_off_ini = 2529.907 uV, v_off_fin = 2541.169 uV 15:06:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 173.677 uVs 15:06:00 Integrated Voltage Measurement... 15:06:09 Voltage Offset Correction: v_off_ini = 2554.974 uV, v_off_fin = 2531.157 uV 15:06:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -154.822 uVs 15:06:09 Integrated Voltage Measurement... 15:06:18 Voltage Offset Correction: v_off_ini = 2544.266 uV, v_off_fin = 2532.283 uV 15:06:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 157.052 uVs 15:06:21 I2X Average and RMS of Measurements VT = -143.932 +- 11.065 uVs I2X = 13.242 +- 1.018 uTm^2 15:06:26 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:06:29 Integrated Voltage Measurement... 15:06:38 Voltage Offset Correction: v_off_ini = 2555.966 uV, v_off_fin = 2546.185 uV 15:06:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -415.088 uVs 15:06:38 Integrated Voltage Measurement... 15:06:47 Voltage Offset Correction: v_off_ini = 2568.012 uV, v_off_fin = 2557.180 uV 15:06:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 376.428 uVs 15:06:47 Integrated Voltage Measurement... 15:06:56 Voltage Offset Correction: v_off_ini = 2546.419 uV, v_off_fin = 2529.286 uV 15:06:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -407.821 uVs 15:06:56 Integrated Voltage Measurement... 15:07:05 Voltage Offset Correction: v_off_ini = 2541.793 uV, v_off_fin = 2565.432 uV 15:07:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.845 uVs 15:07:05 Integrated Voltage Measurement... 15:07:14 Voltage Offset Correction: v_off_ini = 2572.559 uV, v_off_fin = 2543.081 uV 15:07:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -396.125 uVs 15:07:14 Integrated Voltage Measurement... 15:07:23 Voltage Offset Correction: v_off_ini = 2569.795 uV, v_off_fin = 2563.623 uV 15:07:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.017 uVs 15:07:25 I2Y Average and RMS of Measurements VT = -407.054 +- 8.922 uVs I2Y = -37.449 +- 0.821 uTm^2 15:07:33 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:07:37 Integrated Voltage Measurement... 15:07:46 Voltage Offset Correction: v_off_ini = 2572.417 uV, v_off_fin = 2575.169 uV 15:07:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -54.449 uVs 15:07:46 Integrated Voltage Measurement... 15:07:55 Voltage Offset Correction: v_off_ini = 2600.489 uV, v_off_fin = 2567.043 uV 15:07:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.168 uVs 15:07:55 Integrated Voltage Measurement... 15:08:04 Voltage Offset Correction: v_off_ini = 2604.270 uV, v_off_fin = 2580.430 uV 15:08:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.233 uVs 15:08:04 Integrated Voltage Measurement... 15:08:13 Voltage Offset Correction: v_off_ini = 2595.645 uV, v_off_fin = 2579.406 uV 15:08:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.609 uVs 15:08:13 Integrated Voltage Measurement... 15:08:22 Voltage Offset Correction: v_off_ini = 2564.751 uV, v_off_fin = 2568.415 uV 15:08:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.347 uVs 15:08:22 Integrated Voltage Measurement... 15:08:31 Voltage Offset Correction: v_off_ini = 2596.214 uV, v_off_fin = 2599.148 uV 15:08:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.573 uVs 15:08:35 I1X Average and RMS of Measurements VT = -102.896 +- 12.626 uVs I1X = 20.579 +- 2.525 uTm 15:08:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:08:42 Integrated Voltage Measurement... 15:08:51 Voltage Offset Correction: v_off_ini = 2608.229 uV, v_off_fin = 2610.127 uV 15:08:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.341 uVs 15:08:51 Integrated Voltage Measurement... 15:09:00 Voltage Offset Correction: v_off_ini = 2638.753 uV, v_off_fin = 2629.351 uV 15:09:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.126 uVs 15:09:00 Integrated Voltage Measurement... 15:09:09 Voltage Offset Correction: v_off_ini = 2619.205 uV, v_off_fin = 2612.414 uV 15:09:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.732 uVs 15:09:09 Integrated Voltage Measurement... 15:09:18 Voltage Offset Correction: v_off_ini = 2631.361 uV, v_off_fin = 2642.747 uV 15:09:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.296 uVs 15:09:18 Integrated Voltage Measurement... 15:09:27 Voltage Offset Correction: v_off_ini = 2648.680 uV, v_off_fin = 2637.076 uV 15:09:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.224 uVs 15:09:27 Integrated Voltage Measurement... 15:09:36 Voltage Offset Correction: v_off_ini = 2616.200 uV, v_off_fin = 2651.039 uV 15:09:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.429 uVs 15:09:40 I1Y Average and RMS of Measurements VT = -239.358 +- 5.282 uVs I1Y = -47.872 +- 1.056 uTm 15:09:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:09:45 Integrated Voltage Measurement... 15:09:54 Voltage Offset Correction: v_off_ini = 2610.681 uV, v_off_fin = 2576.169 uV 15:09:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -147.979 uVs 15:09:54 Integrated Voltage Measurement... 15:10:03 Voltage Offset Correction: v_off_ini = 2611.970 uV, v_off_fin = 2670.320 uV 15:10:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.366 uVs 15:10:03 Integrated Voltage Measurement... 15:10:12 Voltage Offset Correction: v_off_ini = 2658.235 uV, v_off_fin = 2607.834 uV 15:10:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -151.910 uVs 15:10:12 Integrated Voltage Measurement... 15:10:21 Voltage Offset Correction: v_off_ini = 2619.390 uV, v_off_fin = 2646.060 uV 15:10:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.056 uVs 15:10:21 Integrated Voltage Measurement... 15:10:30 Voltage Offset Correction: v_off_ini = 2648.037 uV, v_off_fin = 2612.634 uV 15:10:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.768 uVs 15:10:30 Integrated Voltage Measurement... 15:10:39 Voltage Offset Correction: v_off_ini = 2592.569 uV, v_off_fin = 2595.668 uV 15:10:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.217 uVs 15:10:42 I2X Average and RMS of Measurements VT = -147.216 +- 3.955 uVs I2X = 13.544 +- 0.364 uTm^2 15:10:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:10:47 Integrated Voltage Measurement... 15:10:56 Voltage Offset Correction: v_off_ini = 2628.254 uV, v_off_fin = 2628.622 uV 15:10:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -401.032 uVs 15:10:56 Integrated Voltage Measurement... 15:11:05 Voltage Offset Correction: v_off_ini = 2604.158 uV, v_off_fin = 2621.850 uV 15:11:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.276 uVs 15:11:05 Integrated Voltage Measurement... 15:11:14 Voltage Offset Correction: v_off_ini = 2587.115 uV, v_off_fin = 2611.288 uV 15:11:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -377.537 uVs 15:11:14 Integrated Voltage Measurement... 15:11:23 Voltage Offset Correction: v_off_ini = 2579.492 uV, v_off_fin = 2607.662 uV 15:11:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.335 uVs 15:11:23 Integrated Voltage Measurement... 15:11:32 Voltage Offset Correction: v_off_ini = 2571.582 uV, v_off_fin = 2577.694 uV 15:11:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.455 uVs 15:11:32 Integrated Voltage Measurement... 15:11:41 Voltage Offset Correction: v_off_ini = 2592.251 uV, v_off_fin = 2604.113 uV 15:11:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 347.595 uVs 15:11:44 I2Y Average and RMS of Measurements VT = -374.372 +- 12.300 uVs I2Y = -34.443 +- 1.131 uTm^2 15:11:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:11:52 Integrated Voltage Measurement... 15:12:01 Voltage Offset Correction: v_off_ini = 2601.656 uV, v_off_fin = 2568.258 uV 15:12:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.002 uVs 15:12:01 Integrated Voltage Measurement... 15:12:10 Voltage Offset Correction: v_off_ini = 2591.727 uV, v_off_fin = 2597.149 uV 15:12:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.659 uVs 15:12:10 Integrated Voltage Measurement... 15:12:19 Voltage Offset Correction: v_off_ini = 2581.252 uV, v_off_fin = 2591.045 uV 15:12:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.914 uVs 15:12:19 Integrated Voltage Measurement... 15:12:28 Voltage Offset Correction: v_off_ini = 2624.094 uV, v_off_fin = 2613.674 uV 15:12:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.594 uVs 15:12:28 Integrated Voltage Measurement... 15:12:37 Voltage Offset Correction: v_off_ini = 2608.421 uV, v_off_fin = 2600.946 uV 15:12:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.323 uVs 15:12:37 Integrated Voltage Measurement... 15:12:46 Voltage Offset Correction: v_off_ini = 2572.922 uV, v_off_fin = 2578.911 uV 15:12:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.386 uVs 15:12:50 I1X Average and RMS of Measurements VT = -138.813 +- 1.235 uVs I1X = 27.763 +- 0.248 uTm 15:12:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:12:57 Integrated Voltage Measurement... 15:13:06 Voltage Offset Correction: v_off_ini = 2622.547 uV, v_off_fin = 2566.152 uV 15:13:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.603 uVs 15:13:06 Integrated Voltage Measurement... 15:13:15 Voltage Offset Correction: v_off_ini = 2592.277 uV, v_off_fin = 2601.813 uV 15:13:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.813 uVs 15:13:15 Integrated Voltage Measurement... 15:13:24 Voltage Offset Correction: v_off_ini = 2582.832 uV, v_off_fin = 2609.916 uV 15:13:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.072 uVs 15:13:24 Integrated Voltage Measurement... 15:13:33 Voltage Offset Correction: v_off_ini = 2598.432 uV, v_off_fin = 2620.756 uV 15:13:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.505 uVs 15:13:33 Integrated Voltage Measurement... 15:13:42 Voltage Offset Correction: v_off_ini = 2587.120 uV, v_off_fin = 2574.609 uV 15:13:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.495 uVs 15:13:42 Integrated Voltage Measurement... 15:13:51 Voltage Offset Correction: v_off_ini = 2561.095 uV, v_off_fin = 2597.390 uV 15:13:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.783 uVs 15:13:55 I1Y Average and RMS of Measurements VT = -232.712 +- 8.593 uVs I1Y = -46.542 +- 1.719 uTm 15:13:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:14:00 Integrated Voltage Measurement... 15:14:09 Voltage Offset Correction: v_off_ini = 2606.227 uV, v_off_fin = 2615.879 uV 15:14:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.599 uVs 15:14:09 Integrated Voltage Measurement... 15:14:18 Voltage Offset Correction: v_off_ini = 2594.666 uV, v_off_fin = 2613.487 uV 15:14:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.327 uVs 15:14:18 Integrated Voltage Measurement... 15:14:27 Voltage Offset Correction: v_off_ini = 2598.692 uV, v_off_fin = 2632.490 uV 15:14:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.297 uVs 15:14:27 Integrated Voltage Measurement... 15:14:36 Voltage Offset Correction: v_off_ini = 2631.348 uV, v_off_fin = 2602.755 uV 15:14:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.641 uVs 15:14:36 Integrated Voltage Measurement... 15:14:45 Voltage Offset Correction: v_off_ini = 2642.196 uV, v_off_fin = 2620.416 uV 15:14:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.319 uVs 15:14:45 Integrated Voltage Measurement... 15:14:54 Voltage Offset Correction: v_off_ini = 2624.913 uV, v_off_fin = 2638.864 uV 15:14:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.836 uVs 15:14:57 I2X Average and RMS of Measurements VT = -129.670 +- 1.392 uVs I2X = 11.930 +- 0.128 uTm^2 15:14:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:15:02 Integrated Voltage Measurement... 15:15:11 Voltage Offset Correction: v_off_ini = 2591.340 uV, v_off_fin = 2598.225 uV 15:15:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -374.079 uVs 15:15:11 Integrated Voltage Measurement... 15:15:20 Voltage Offset Correction: v_off_ini = 2636.199 uV, v_off_fin = 2638.533 uV 15:15:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.667 uVs 15:15:20 Integrated Voltage Measurement... 15:15:29 Voltage Offset Correction: v_off_ini = 2656.951 uV, v_off_fin = 2668.356 uV 15:15:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.777 uVs 15:15:29 Integrated Voltage Measurement... 15:15:38 Voltage Offset Correction: v_off_ini = 2648.768 uV, v_off_fin = 2655.023 uV 15:15:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.180 uVs 15:15:38 Integrated Voltage Measurement... 15:15:47 Voltage Offset Correction: v_off_ini = 2653.116 uV, v_off_fin = 2640.429 uV 15:15:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.461 uVs 15:15:47 Integrated Voltage Measurement... 15:15:56 Voltage Offset Correction: v_off_ini = 2631.996 uV, v_off_fin = 2666.970 uV 15:15:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 432.566 uVs 15:15:58 I2Y Average and RMS of Measurements VT = -377.788 +- 22.375 uVs I2Y = -34.757 +- 2.058 uTm^2 15:16:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:07 Integrated Voltage Measurement... 15:16:15 Voltage Offset Correction: v_off_ini = 2660.657 uV, v_off_fin = 2664.902 uV 15:16:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -102.071 uVs 15:16:16 Integrated Voltage Measurement... 15:16:24 Voltage Offset Correction: v_off_ini = 2669.926 uV, v_off_fin = 2687.661 uV 15:16:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.996 uVs 15:16:25 Integrated Voltage Measurement... 15:16:33 Voltage Offset Correction: v_off_ini = 2683.209 uV, v_off_fin = 2689.113 uV 15:16:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.722 uVs 15:16:34 Integrated Voltage Measurement... 15:16:42 Voltage Offset Correction: v_off_ini = 2687.278 uV, v_off_fin = 2686.318 uV 15:16:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.302 uVs 15:16:43 Integrated Voltage Measurement... 15:16:52 Voltage Offset Correction: v_off_ini = 2647.210 uV, v_off_fin = 2686.997 uV 15:16:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.524 uVs 15:16:52 Integrated Voltage Measurement... 15:17:01 Voltage Offset Correction: v_off_ini = 2675.001 uV, v_off_fin = 2703.139 uV 15:17:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.352 uVs 15:17:05 I1X Average and RMS of Measurements VT = -108.495 +- 11.458 uVs I1X = 21.700 +- 2.291 uTm 15:17:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:17:12 Integrated Voltage Measurement... 15:17:20 Voltage Offset Correction: v_off_ini = 2691.126 uV, v_off_fin = 2720.053 uV 15:17:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.762 uVs 15:17:21 Integrated Voltage Measurement... 15:17:29 Voltage Offset Correction: v_off_ini = 2697.426 uV, v_off_fin = 2718.532 uV 15:17:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.500 uVs 15:17:30 Integrated Voltage Measurement... 15:17:38 Voltage Offset Correction: v_off_ini = 2719.223 uV, v_off_fin = 2696.541 uV 15:17:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.315 uVs 15:17:39 Integrated Voltage Measurement... 15:17:47 Voltage Offset Correction: v_off_ini = 2714.310 uV, v_off_fin = 2704.547 uV 15:17:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.613 uVs 15:17:48 Integrated Voltage Measurement... 15:17:56 Voltage Offset Correction: v_off_ini = 2716.726 uV, v_off_fin = 2690.526 uV 15:17:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.879 uVs 15:17:57 Integrated Voltage Measurement... 15:18:05 Voltage Offset Correction: v_off_ini = 2691.348 uV, v_off_fin = 2728.968 uV 15:18:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 307.239 uVs 15:18:10 I1Y Average and RMS of Measurements VT = -259.051 +- 29.371 uVs I1Y = -51.810 +- 5.874 uTm 15:18:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:18:15 Integrated Voltage Measurement... 15:18:24 Voltage Offset Correction: v_off_ini = 2692.801 uV, v_off_fin = 2703.356 uV 15:18:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.133 uVs 15:18:24 Integrated Voltage Measurement... 15:18:33 Voltage Offset Correction: v_off_ini = 2707.022 uV, v_off_fin = 2722.784 uV 15:18:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 164.790 uVs 15:18:33 Integrated Voltage Measurement... 15:18:42 Voltage Offset Correction: v_off_ini = 2695.015 uV, v_off_fin = 2699.814 uV 15:18:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.241 uVs 15:18:42 Integrated Voltage Measurement... 15:18:51 Voltage Offset Correction: v_off_ini = 2737.094 uV, v_off_fin = 2750.051 uV 15:18:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 106.315 uVs 15:18:51 Integrated Voltage Measurement... 15:19:00 Voltage Offset Correction: v_off_ini = 2740.570 uV, v_off_fin = 2741.732 uV 15:19:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -139.753 uVs 15:19:00 Integrated Voltage Measurement... 15:19:09 Voltage Offset Correction: v_off_ini = 2730.501 uV, v_off_fin = 2724.812 uV 15:19:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 57.984 uVs 15:19:11 I2X Average and RMS of Measurements VT = -119.036 +- 23.155 uVs I2X = 10.952 +- 2.130 uTm^2 15:19:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:16 Integrated Voltage Measurement... 15:19:25 Voltage Offset Correction: v_off_ini = 2738.280 uV, v_off_fin = 2735.649 uV 15:19:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.602 uVs 15:19:26 Integrated Voltage Measurement... 15:19:34 Voltage Offset Correction: v_off_ini = 2737.612 uV, v_off_fin = 2803.783 uV 15:19:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 381.320 uVs 15:19:35 Integrated Voltage Measurement... 15:19:44 Voltage Offset Correction: v_off_ini = 2807.767 uV, v_off_fin = 2764.116 uV 15:19:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -392.412 uVs 15:19:44 Integrated Voltage Measurement... 15:19:53 Voltage Offset Correction: v_off_ini = 2769.217 uV, v_off_fin = 2785.472 uV 15:19:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 409.592 uVs 15:19:53 Integrated Voltage Measurement... 15:20:02 Voltage Offset Correction: v_off_ini = 2812.922 uV, v_off_fin = 2801.502 uV 15:20:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -398.197 uVs 15:20:02 Integrated Voltage Measurement... 15:20:11 Voltage Offset Correction: v_off_ini = 2782.139 uV, v_off_fin = 2792.790 uV 15:20:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.707 uVs 15:20:13 I2Y Average and RMS of Measurements VT = -383.138 +- 12.647 uVs I2Y = -35.249 +- 1.164 uTm^2 15:20:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:20:21 Integrated Voltage Measurement... 15:20:30 Voltage Offset Correction: v_off_ini = 2788.841 uV, v_off_fin = 2758.357 uV 15:20:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.225 uVs 15:20:30 Integrated Voltage Measurement... 15:20:39 Voltage Offset Correction: v_off_ini = 2781.019 uV, v_off_fin = 2785.575 uV 15:20:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.449 uVs 15:20:39 Integrated Voltage Measurement... 15:20:48 Voltage Offset Correction: v_off_ini = 2791.314 uV, v_off_fin = 2759.571 uV 15:20:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.246 uVs 15:20:48 Integrated Voltage Measurement... 15:20:57 Voltage Offset Correction: v_off_ini = 2769.178 uV, v_off_fin = 2803.473 uV 15:20:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.466 uVs 15:20:57 Integrated Voltage Measurement... 15:21:06 Voltage Offset Correction: v_off_ini = 2766.596 uV, v_off_fin = 2778.615 uV 15:21:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.720 uVs 15:21:06 Integrated Voltage Measurement... 15:21:15 Voltage Offset Correction: v_off_ini = 2780.176 uV, v_off_fin = 2800.069 uV 15:21:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.402 uVs 15:21:20 I1X Average and RMS of Measurements VT = -112.751 +- 8.517 uVs I1X = 22.551 +- 1.704 uTm 15:21:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:21:26 Integrated Voltage Measurement... 15:21:35 Voltage Offset Correction: v_off_ini = 2801.481 uV, v_off_fin = 2810.639 uV 15:21:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.680 uVs 15:21:35 Integrated Voltage Measurement... 15:21:44 Voltage Offset Correction: v_off_ini = 2821.187 uV, v_off_fin = 2835.125 uV 15:21:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.281 uVs 15:21:44 Integrated Voltage Measurement... 15:21:53 Voltage Offset Correction: v_off_ini = 2832.825 uV, v_off_fin = 2829.419 uV 15:21:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.555 uVs 15:21:53 Integrated Voltage Measurement... 15:22:02 Voltage Offset Correction: v_off_ini = 2831.640 uV, v_off_fin = 2845.029 uV 15:22:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.558 uVs 15:22:02 Integrated Voltage Measurement... 15:22:11 Voltage Offset Correction: v_off_ini = 2829.095 uV, v_off_fin = 2805.794 uV 15:22:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.603 uVs 15:22:11 Integrated Voltage Measurement... 15:22:20 Voltage Offset Correction: v_off_ini = 2796.507 uV, v_off_fin = 2824.551 uV 15:22:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.999 uVs 15:22:24 I1Y Average and RMS of Measurements VT = -233.613 +- 18.314 uVs I1Y = -46.723 +- 3.663 uTm 15:22:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:22:30 Integrated Voltage Measurement... 15:22:39 Voltage Offset Correction: v_off_ini = 2793.934 uV, v_off_fin = 2801.894 uV 15:22:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.075 uVs 15:22:39 Integrated Voltage Measurement... 15:22:48 Voltage Offset Correction: v_off_ini = 2811.367 uV, v_off_fin = 2815.036 uV 15:22:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.190 uVs 15:22:48 Integrated Voltage Measurement... 15:22:57 Voltage Offset Correction: v_off_ini = 2792.215 uV, v_off_fin = 2778.996 uV 15:22:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.648 uVs 15:22:57 Integrated Voltage Measurement... 15:23:06 Voltage Offset Correction: v_off_ini = 2766.011 uV, v_off_fin = 2776.756 uV 15:23:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.093 uVs 15:23:06 Integrated Voltage Measurement... 15:23:15 Voltage Offset Correction: v_off_ini = 2753.723 uV, v_off_fin = 2758.551 uV 15:23:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.248 uVs 15:23:15 Integrated Voltage Measurement... 15:23:24 Voltage Offset Correction: v_off_ini = 2771.933 uV, v_off_fin = 2788.560 uV 15:23:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.257 uVs 15:23:26 I2X Average and RMS of Measurements VT = -121.085 +- 5.864 uVs I2X = 11.140 +- 0.540 uTm^2 15:23:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:23:31 Integrated Voltage Measurement... 15:23:40 Voltage Offset Correction: v_off_ini = 2766.990 uV, v_off_fin = 2742.594 uV 15:23:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -394.668 uVs 15:23:40 Integrated Voltage Measurement... 15:23:49 Voltage Offset Correction: v_off_ini = 2737.793 uV, v_off_fin = 2744.995 uV 15:23:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.235 uVs 15:23:49 Integrated Voltage Measurement... 15:23:58 Voltage Offset Correction: v_off_ini = 2767.894 uV, v_off_fin = 2792.360 uV 15:23:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -382.861 uVs 15:23:58 Integrated Voltage Measurement... 15:24:07 Voltage Offset Correction: v_off_ini = 2792.650 uV, v_off_fin = 2802.636 uV 15:24:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.683 uVs 15:24:07 Integrated Voltage Measurement... 15:24:16 Voltage Offset Correction: v_off_ini = 2773.280 uV, v_off_fin = 2767.831 uV 15:24:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -398.172 uVs 15:24:16 Integrated Voltage Measurement... 15:24:25 Voltage Offset Correction: v_off_ini = 2791.550 uV, v_off_fin = 2812.271 uV 15:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.033 uVs 15:24:28 I2Y Average and RMS of Measurements VT = -379.942 +- 7.928 uVs I2Y = -34.955 +- 0.729 uTm^2 15:24:32 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:24:36 Integrated Voltage Measurement... 15:24:45 Voltage Offset Correction: v_off_ini = 2798.982 uV, v_off_fin = 2797.510 uV 15:24:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -146.101 uVs 15:24:45 Integrated Voltage Measurement... 15:24:54 Voltage Offset Correction: v_off_ini = 2822.841 uV, v_off_fin = 2793.771 uV 15:24:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.330 uVs 15:24:54 Integrated Voltage Measurement... 15:25:03 Voltage Offset Correction: v_off_ini = 2765.332 uV, v_off_fin = 2792.353 uV 15:25:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -46.135 uVs 15:25:03 Integrated Voltage Measurement... 15:25:12 Voltage Offset Correction: v_off_ini = 2760.809 uV, v_off_fin = 2801.020 uV 15:25:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 120.791 uVs 15:25:12 Integrated Voltage Measurement... 15:25:21 Voltage Offset Correction: v_off_ini = 2808.727 uV, v_off_fin = 2764.855 uV 15:25:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.141 uVs 15:25:21 Integrated Voltage Measurement... 15:25:30 Voltage Offset Correction: v_off_ini = 2816.760 uV, v_off_fin = 2815.982 uV 15:25:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.857 uVs 15:25:34 I1X Average and RMS of Measurements VT = -108.393 +- 20.027 uVs I1X = 21.680 +- 4.005 uTm 15:25:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:25:41 Integrated Voltage Measurement... 15:25:50 Voltage Offset Correction: v_off_ini = 2785.149 uV, v_off_fin = 2748.942 uV 15:25:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -263.426 uVs 15:25:50 Integrated Voltage Measurement... 15:25:59 Voltage Offset Correction: v_off_ini = 2772.688 uV, v_off_fin = 2822.202 uV 15:25:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 271.045 uVs 15:25:59 Integrated Voltage Measurement... 15:26:08 Voltage Offset Correction: v_off_ini = 2805.874 uV, v_off_fin = 2783.821 uV 15:26:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -236.824 uVs 15:26:08 Integrated Voltage Measurement... 15:26:17 Voltage Offset Correction: v_off_ini = 2799.054 uV, v_off_fin = 2820.104 uV 15:26:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 262.967 uVs 15:26:17 Integrated Voltage Measurement... 15:26:26 Voltage Offset Correction: v_off_ini = 2797.044 uV, v_off_fin = 2801.258 uV 15:26:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -250.742 uVs 15:26:26 Integrated Voltage Measurement... 15:26:35 Voltage Offset Correction: v_off_ini = 2765.369 uV, v_off_fin = 2807.315 uV 15:26:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 268.712 uVs 15:26:39 I1Y Average and RMS of Measurements VT = -258.953 +- 7.100 uVs I1Y = -51.785 +- 1.420 uTm 15:26:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:26:44 Integrated Voltage Measurement... 15:26:53 Voltage Offset Correction: v_off_ini = 2790.509 uV, v_off_fin = 2760.995 uV 15:26:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.396 uVs 15:26:53 Integrated Voltage Measurement... 15:27:02 Voltage Offset Correction: v_off_ini = 2781.619 uV, v_off_fin = 2768.834 uV 15:27:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.511 uVs 15:27:02 Integrated Voltage Measurement... 15:27:11 Voltage Offset Correction: v_off_ini = 2777.660 uV, v_off_fin = 2755.325 uV 15:27:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.033 uVs 15:27:11 Integrated Voltage Measurement... 15:27:20 Voltage Offset Correction: v_off_ini = 2758.375 uV, v_off_fin = 2783.583 uV 15:27:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.463 uVs 15:27:20 Integrated Voltage Measurement... 15:27:29 Voltage Offset Correction: v_off_ini = 2812.456 uV, v_off_fin = 2792.243 uV 15:27:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.883 uVs 15:27:29 Integrated Voltage Measurement... 15:27:38 Voltage Offset Correction: v_off_ini = 2802.947 uV, v_off_fin = 2778.773 uV 15:27:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.089 uVs 15:27:40 I2X Average and RMS of Measurements VT = -109.729 +- 8.317 uVs I2X = 10.095 +- 0.765 uTm^2 15:27:43 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:27:45 Integrated Voltage Measurement... 15:27:54 Voltage Offset Correction: v_off_ini = 2789.868 uV, v_off_fin = 2761.135 uV 15:27:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -436.409 uVs 15:27:54 Integrated Voltage Measurement... 15:28:03 Voltage Offset Correction: v_off_ini = 2784.748 uV, v_off_fin = 2814.399 uV 15:28:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.169 uVs 15:28:03 Integrated Voltage Measurement... 15:28:12 Voltage Offset Correction: v_off_ini = 2814.374 uV, v_off_fin = 2814.909 uV 15:28:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -387.775 uVs 15:28:12 Integrated Voltage Measurement... 15:28:21 Voltage Offset Correction: v_off_ini = 2828.020 uV, v_off_fin = 2807.545 uV 15:28:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 396.943 uVs 15:28:22 Integrated Voltage Measurement... 15:28:30 Voltage Offset Correction: v_off_ini = 2842.691 uV, v_off_fin = 2811.540 uV 15:28:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -388.371 uVs 15:28:31 Integrated Voltage Measurement... 15:28:39 Voltage Offset Correction: v_off_ini = 2810.606 uV, v_off_fin = 2812.280 uV 15:28:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 394.770 uVs 15:28:42 I2Y Average and RMS of Measurements VT = -393.740 +- 2.531 uVs I2Y = -36.225 +- 0.232 uTm^2 15:28:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:29:02 Integrated Voltage Measurement... 15:29:11 Voltage Offset Correction: v_off_ini = 2837.707 uV, v_off_fin = 2840.121 uV 15:29:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -97.965 uVs 15:29:11 Integrated Voltage Measurement... 15:29:20 Voltage Offset Correction: v_off_ini = 2831.018 uV, v_off_fin = 2788.956 uV 15:29:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 92.554 uVs 15:29:20 Integrated Voltage Measurement... 15:29:29 Voltage Offset Correction: v_off_ini = 2794.417 uV, v_off_fin = 2800.680 uV 15:29:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.179 uVs 15:29:29 Integrated Voltage Measurement... 15:29:38 Voltage Offset Correction: v_off_ini = 2843.631 uV, v_off_fin = 2849.697 uV 15:29:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.587 uVs 15:29:38 Integrated Voltage Measurement... 15:29:47 Voltage Offset Correction: v_off_ini = 2829.656 uV, v_off_fin = 2801.500 uV 15:29:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.234 uVs 15:29:47 Integrated Voltage Measurement... 15:29:56 Voltage Offset Correction: v_off_ini = 2839.083 uV, v_off_fin = 2834.634 uV 15:29:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.269 uVs 15:30:00 I1X Average and RMS of Measurements VT = -106.465 +- 10.174 uVs I1X = 21.294 +- 2.034 uTm 15:30:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:30:07 Integrated Voltage Measurement... 15:30:16 Voltage Offset Correction: v_off_ini = 2816.942 uV, v_off_fin = 2823.286 uV 15:30:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.967 uVs 15:30:16 Integrated Voltage Measurement... 15:30:25 Voltage Offset Correction: v_off_ini = 2830.022 uV, v_off_fin = 2836.493 uV 15:30:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.495 uVs 15:30:25 Integrated Voltage Measurement... 15:30:34 Voltage Offset Correction: v_off_ini = 2857.975 uV, v_off_fin = 2863.382 uV 15:30:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.060 uVs 15:30:34 Integrated Voltage Measurement... 15:30:43 Voltage Offset Correction: v_off_ini = 2808.356 uV, v_off_fin = 2832.453 uV 15:30:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.414 uVs 15:30:43 Integrated Voltage Measurement... 15:30:52 Voltage Offset Correction: v_off_ini = 2824.524 uV, v_off_fin = 2829.629 uV 15:30:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.570 uVs 15:30:52 Integrated Voltage Measurement... 15:31:01 Voltage Offset Correction: v_off_ini = 2837.466 uV, v_off_fin = 2846.349 uV 15:31:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.696 uVs 15:31:05 I1Y Average and RMS of Measurements VT = -219.867 +- 5.356 uVs I1Y = -43.973 +- 1.071 uTm 15:31:10 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:31:13 Integrated Voltage Measurement... 15:31:22 Voltage Offset Correction: v_off_ini = 2858.050 uV, v_off_fin = 2813.248 uV 15:31:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.679 uVs 15:31:22 Integrated Voltage Measurement... 15:31:31 Voltage Offset Correction: v_off_ini = 2856.320 uV, v_off_fin = 2882.895 uV 15:31:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.718 uVs 15:31:31 Integrated Voltage Measurement... 15:31:40 Voltage Offset Correction: v_off_ini = 2903.276 uV, v_off_fin = 2890.127 uV 15:31:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.864 uVs 15:31:40 Integrated Voltage Measurement... 15:31:49 Voltage Offset Correction: v_off_ini = 2869.306 uV, v_off_fin = 2888.338 uV 15:31:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.476 uVs 15:31:49 Integrated Voltage Measurement... 15:31:58 Voltage Offset Correction: v_off_ini = 2855.088 uV, v_off_fin = 2842.918 uV 15:31:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.494 uVs 15:31:58 Integrated Voltage Measurement... 15:32:07 Voltage Offset Correction: v_off_ini = 2889.652 uV, v_off_fin = 2902.046 uV 15:32:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.539 uVs 15:32:09 I2X Average and RMS of Measurements VT = -98.795 +- 6.214 uVs I2X = 9.089 +- 0.572 uTm^2 15:32:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:32:17 Integrated Voltage Measurement... 15:32:26 Voltage Offset Correction: v_off_ini = 2845.866 uV, v_off_fin = 2872.749 uV 15:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.589 uVs 15:32:26 Integrated Voltage Measurement... 15:32:35 Voltage Offset Correction: v_off_ini = 2854.252 uV, v_off_fin = 2866.365 uV 15:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.616 uVs 15:32:35 Integrated Voltage Measurement... 15:32:44 Voltage Offset Correction: v_off_ini = 2856.372 uV, v_off_fin = 2879.352 uV 15:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -347.043 uVs 15:32:44 Integrated Voltage Measurement... 15:32:53 Voltage Offset Correction: v_off_ini = 2915.376 uV, v_off_fin = 2864.446 uV 15:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.427 uVs 15:32:53 Integrated Voltage Measurement... 15:33:02 Voltage Offset Correction: v_off_ini = 2859.158 uV, v_off_fin = 2856.110 uV 15:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -362.247 uVs 15:33:02 Integrated Voltage Measurement... 15:33:11 Voltage Offset Correction: v_off_ini = 2885.706 uV, v_off_fin = 2903.532 uV 15:33:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.918 uVs 15:33:13 I2Y Average and RMS of Measurements VT = -356.640 +- 1.419 uVs I2Y = -32.811 +- 0.131 uTm^2 15:33:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:33:22 Integrated Voltage Measurement... 15:33:31 Voltage Offset Correction: v_off_ini = 2886.072 uV, v_off_fin = 2901.806 uV 15:33:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -117.544 uVs 15:33:31 Integrated Voltage Measurement... 15:33:40 Voltage Offset Correction: v_off_ini = 2883.939 uV, v_off_fin = 2917.511 uV 15:33:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.130 uVs 15:33:40 Integrated Voltage Measurement... 15:33:49 Voltage Offset Correction: v_off_ini = 2906.750 uV, v_off_fin = 2881.820 uV 15:33:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.090 uVs 15:33:49 Integrated Voltage Measurement... 15:33:58 Voltage Offset Correction: v_off_ini = 2927.903 uV, v_off_fin = 2864.309 uV 15:33:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.483 uVs 15:33:58 Integrated Voltage Measurement... 15:34:07 Voltage Offset Correction: v_off_ini = 2911.652 uV, v_off_fin = 2909.172 uV 15:34:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.910 uVs 15:34:07 Integrated Voltage Measurement... 15:34:16 Voltage Offset Correction: v_off_ini = 2901.745 uV, v_off_fin = 2887.874 uV 15:34:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.284 uVs 15:34:20 I1X Average and RMS of Measurements VT = -102.240 +- 7.178 uVs I1X = 20.448 +- 1.436 uTm 15:34:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:34:27 Integrated Voltage Measurement... 15:34:36 Voltage Offset Correction: v_off_ini = 2906.923 uV, v_off_fin = 2903.617 uV 15:34:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.016 uVs 15:34:36 Integrated Voltage Measurement... 15:34:45 Voltage Offset Correction: v_off_ini = 2898.741 uV, v_off_fin = 2893.715 uV 15:34:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.818 uVs 15:34:45 Integrated Voltage Measurement... 15:34:54 Voltage Offset Correction: v_off_ini = 2910.664 uV, v_off_fin = 2930.272 uV 15:34:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.667 uVs 15:34:54 Integrated Voltage Measurement... 15:35:03 Voltage Offset Correction: v_off_ini = 2930.577 uV, v_off_fin = 2941.628 uV 15:35:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.391 uVs 15:35:03 Integrated Voltage Measurement... 15:35:12 Voltage Offset Correction: v_off_ini = 2911.055 uV, v_off_fin = 2879.223 uV 15:35:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.731 uVs 15:35:12 Integrated Voltage Measurement... 15:35:21 Voltage Offset Correction: v_off_ini = 2885.778 uV, v_off_fin = 2896.656 uV 15:35:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.796 uVs 15:35:25 I1Y Average and RMS of Measurements VT = -232.903 +- 8.481 uVs I1Y = -46.581 +- 1.696 uTm 15:35:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:35:33 Integrated Voltage Measurement... 15:35:42 Voltage Offset Correction: v_off_ini = 2909.422 uV, v_off_fin = 2926.344 uV 15:35:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -127.289 uVs 15:35:42 Integrated Voltage Measurement... 15:35:51 Voltage Offset Correction: v_off_ini = 2921.626 uV, v_off_fin = 2862.952 uV 15:35:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.681 uVs 15:35:51 Integrated Voltage Measurement... 15:36:00 Voltage Offset Correction: v_off_ini = 2872.738 uV, v_off_fin = 2895.464 uV 15:36:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.624 uVs 15:36:00 Integrated Voltage Measurement... 15:36:09 Voltage Offset Correction: v_off_ini = 2875.594 uV, v_off_fin = 2882.177 uV 15:36:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.462 uVs 15:36:09 Integrated Voltage Measurement... 15:36:18 Voltage Offset Correction: v_off_ini = 2886.130 uV, v_off_fin = 2888.486 uV 15:36:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.279 uVs 15:36:18 Integrated Voltage Measurement... 15:36:27 Voltage Offset Correction: v_off_ini = 2880.867 uV, v_off_fin = 2881.933 uV 15:36:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.051 uVs 15:36:29 I2X Average and RMS of Measurements VT = -120.231 +- 18.555 uVs I2X = 11.061 +- 1.707 uTm^2 15:36:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:36:37 Integrated Voltage Measurement... 15:36:46 Voltage Offset Correction: v_off_ini = 2852.748 uV, v_off_fin = 2893.395 uV 15:36:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -338.350 uVs 15:36:46 Integrated Voltage Measurement... 15:36:55 Voltage Offset Correction: v_off_ini = 2868.141 uV, v_off_fin = 2909.255 uV 15:36:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.739 uVs 15:36:55 Integrated Voltage Measurement... 15:37:04 Voltage Offset Correction: v_off_ini = 2902.326 uV, v_off_fin = 2886.777 uV 15:37:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.404 uVs 15:37:04 Integrated Voltage Measurement... 15:37:13 Voltage Offset Correction: v_off_ini = 2893.874 uV, v_off_fin = 2870.444 uV 15:37:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.791 uVs 15:37:13 Integrated Voltage Measurement... 15:37:22 Voltage Offset Correction: v_off_ini = 2888.131 uV, v_off_fin = 2894.475 uV 15:37:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.171 uVs 15:37:22 Integrated Voltage Measurement... 15:37:31 Voltage Offset Correction: v_off_ini = 2872.294 uV, v_off_fin = 2867.509 uV 15:37:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 380.827 uVs 15:37:33 I2Y Average and RMS of Measurements VT = -360.881 +- 24.803 uVs I2Y = -33.201 +- 2.282 uTm^2 15:37:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:37:42 Integrated Voltage Measurement... 15:37:51 Voltage Offset Correction: v_off_ini = 2856.391 uV, v_off_fin = 2863.691 uV 15:37:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.473 uVs 15:37:51 Integrated Voltage Measurement... 15:38:00 Voltage Offset Correction: v_off_ini = 2866.005 uV, v_off_fin = 2875.939 uV 15:38:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.272 uVs 15:38:00 Integrated Voltage Measurement... 15:38:09 Voltage Offset Correction: v_off_ini = 2860.661 uV, v_off_fin = 2860.912 uV 15:38:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.739 uVs 15:38:09 Integrated Voltage Measurement... 15:38:18 Voltage Offset Correction: v_off_ini = 2840.930 uV, v_off_fin = 2890.820 uV 15:38:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.284 uVs 15:38:18 Integrated Voltage Measurement... 15:38:27 Voltage Offset Correction: v_off_ini = 2892.084 uV, v_off_fin = 2878.180 uV 15:38:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.288 uVs 15:38:27 Integrated Voltage Measurement... 15:38:36 Voltage Offset Correction: v_off_ini = 2895.298 uV, v_off_fin = 2897.905 uV 15:38:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.205 uVs 15:38:41 I1X Average and RMS of Measurements VT = -125.043 +- 18.648 uVs I1X = 25.009 +- 3.730 uTm 15:38:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:47 Integrated Voltage Measurement... 15:38:56 Voltage Offset Correction: v_off_ini = 2890.335 uV, v_off_fin = 2892.532 uV 15:38:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.146 uVs 15:38:56 Integrated Voltage Measurement... 15:39:05 Voltage Offset Correction: v_off_ini = 2889.109 uV, v_off_fin = 2896.243 uV 15:39:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.311 uVs 15:39:05 Integrated Voltage Measurement... 15:39:14 Voltage Offset Correction: v_off_ini = 2905.547 uV, v_off_fin = 2868.901 uV 15:39:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.765 uVs 15:39:14 Integrated Voltage Measurement... 15:39:23 Voltage Offset Correction: v_off_ini = 2893.873 uV, v_off_fin = 2887.940 uV 15:39:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.812 uVs 15:39:23 Integrated Voltage Measurement... 15:39:32 Voltage Offset Correction: v_off_ini = 2920.431 uV, v_off_fin = 2887.209 uV 15:39:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.609 uVs 15:39:32 Integrated Voltage Measurement... 15:39:41 Voltage Offset Correction: v_off_ini = 2870.641 uV, v_off_fin = 2909.577 uV 15:39:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.995 uVs 15:39:45 I1Y Average and RMS of Measurements VT = -237.106 +- 18.821 uVs I1Y = -47.421 +- 3.764 uTm 15:39:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:39:53 Integrated Voltage Measurement... 15:40:02 Voltage Offset Correction: v_off_ini = 2898.060 uV, v_off_fin = 2911.111 uV 15:40:02 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -123.083 uVs 15:40:02 Integrated Voltage Measurement... 15:40:11 Voltage Offset Correction: v_off_ini = 2932.730 uV, v_off_fin = 2941.981 uV 15:40:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.616 uVs 15:40:11 Integrated Voltage Measurement... 15:40:20 Voltage Offset Correction: v_off_ini = 2911.280 uV, v_off_fin = 2904.556 uV 15:40:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.028 uVs 15:40:20 Integrated Voltage Measurement... 15:40:29 Voltage Offset Correction: v_off_ini = 2894.483 uV, v_off_fin = 2941.837 uV 15:40:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 59.605 uVs 15:40:29 Integrated Voltage Measurement... 15:40:38 Voltage Offset Correction: v_off_ini = 2909.454 uV, v_off_fin = 2928.399 uV 15:40:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -192.069 uVs 15:40:38 Integrated Voltage Measurement... 15:40:47 Voltage Offset Correction: v_off_ini = 2944.142 uV, v_off_fin = 2922.038 uV 15:40:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.979 uVs 15:40:50 I2X Average and RMS of Measurements VT = -123.230 +- 33.390 uVs I2X = 11.337 +- 3.072 uTm^2 15:40:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:57 Integrated Voltage Measurement... 15:41:06 Voltage Offset Correction: v_off_ini = 2908.357 uV, v_off_fin = 2928.069 uV 15:41:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.039 uVs 15:41:06 Integrated Voltage Measurement... 15:41:15 Voltage Offset Correction: v_off_ini = 2939.884 uV, v_off_fin = 2925.754 uV 15:41:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.142 uVs 15:41:15 Integrated Voltage Measurement... 15:41:24 Voltage Offset Correction: v_off_ini = 2897.760 uV, v_off_fin = 2907.934 uV 15:41:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.644 uVs 15:41:24 Integrated Voltage Measurement... 15:41:33 Voltage Offset Correction: v_off_ini = 2905.935 uV, v_off_fin = 2895.323 uV 15:41:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 400.896 uVs 15:41:33 Integrated Voltage Measurement... 15:41:42 Voltage Offset Correction: v_off_ini = 2893.343 uV, v_off_fin = 2872.158 uV 15:41:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.337 uVs 15:41:42 Integrated Voltage Measurement... 15:41:51 Voltage Offset Correction: v_off_ini = 2931.170 uV, v_off_fin = 2948.614 uV 15:41:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.504 uVs 15:41:54 I2Y Average and RMS of Measurements VT = -363.427 +- 25.133 uVs I2Y = -33.435 +- 2.312 uTm^2 15:41:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:42:03 Integrated Voltage Measurement... 15:42:12 Voltage Offset Correction: v_off_ini = 2890.045 uV, v_off_fin = 2895.238 uV 15:42:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.178 uVs 15:42:12 Integrated Voltage Measurement... 15:42:21 Voltage Offset Correction: v_off_ini = 2882.192 uV, v_off_fin = 2900.341 uV 15:42:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.010 uVs 15:42:21 Integrated Voltage Measurement... 15:42:30 Voltage Offset Correction: v_off_ini = 2906.766 uV, v_off_fin = 2881.984 uV 15:42:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.937 uVs 15:42:30 Integrated Voltage Measurement... 15:42:39 Voltage Offset Correction: v_off_ini = 2902.741 uV, v_off_fin = 2878.802 uV 15:42:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.241 uVs 15:42:39 Integrated Voltage Measurement... 15:42:48 Voltage Offset Correction: v_off_ini = 2885.039 uV, v_off_fin = 2873.484 uV 15:42:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.827 uVs 15:42:48 Integrated Voltage Measurement... 15:42:57 Voltage Offset Correction: v_off_ini = 2876.081 uV, v_off_fin = 2895.148 uV 15:42:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.949 uVs 15:43:01 I1X Average and RMS of Measurements VT = -104.690 +- 7.624 uVs I1X = 20.939 +- 1.525 uTm 15:43:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:43:08 Integrated Voltage Measurement... 15:43:17 Voltage Offset Correction: v_off_ini = 2908.339 uV, v_off_fin = 2914.010 uV 15:43:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.340 uVs 15:43:17 Integrated Voltage Measurement... 15:43:26 Voltage Offset Correction: v_off_ini = 2936.579 uV, v_off_fin = 2935.841 uV 15:43:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.523 uVs 15:43:26 Integrated Voltage Measurement... 15:43:35 Voltage Offset Correction: v_off_ini = 2942.078 uV, v_off_fin = 2933.596 uV 15:43:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.406 uVs 15:43:35 Integrated Voltage Measurement... 15:43:44 Voltage Offset Correction: v_off_ini = 2934.187 uV, v_off_fin = 2940.237 uV 15:43:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.699 uVs 15:43:44 Integrated Voltage Measurement... 15:43:53 Voltage Offset Correction: v_off_ini = 2940.850 uV, v_off_fin = 2908.334 uV 15:43:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.865 uVs 15:43:53 Integrated Voltage Measurement... 15:44:02 Voltage Offset Correction: v_off_ini = 2945.689 uV, v_off_fin = 2949.676 uV 15:44:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.064 uVs 15:44:06 I1Y Average and RMS of Measurements VT = -238.483 +- 7.572 uVs I1Y = -47.697 +- 1.514 uTm 15:44:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:44:14 Integrated Voltage Measurement... 15:44:23 Voltage Offset Correction: v_off_ini = 2947.853 uV, v_off_fin = 2952.412 uV 15:44:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.379 uVs 15:44:23 Integrated Voltage Measurement... 15:44:32 Voltage Offset Correction: v_off_ini = 2930.358 uV, v_off_fin = 2963.661 uV 15:44:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.092 uVs 15:44:32 Integrated Voltage Measurement... 15:44:41 Voltage Offset Correction: v_off_ini = 2976.844 uV, v_off_fin = 2961.613 uV 15:44:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.592 uVs 15:44:41 Integrated Voltage Measurement... 15:44:50 Voltage Offset Correction: v_off_ini = 2913.998 uV, v_off_fin = 2963.207 uV 15:44:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 163.140 uVs 15:44:50 Integrated Voltage Measurement... 15:44:59 Voltage Offset Correction: v_off_ini = 2955.911 uV, v_off_fin = 2944.528 uV 15:44:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.268 uVs 15:44:59 Integrated Voltage Measurement... 15:45:08 Voltage Offset Correction: v_off_ini = 2944.329 uV, v_off_fin = 2972.330 uV 15:45:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.261 uVs 15:45:10 I2X Average and RMS of Measurements VT = -142.955 +- 8.021 uVs I2X = 13.152 +- 0.738 uTm^2 15:45:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:45:18 Integrated Voltage Measurement... 15:45:27 Voltage Offset Correction: v_off_ini = 2923.187 uV, v_off_fin = 2925.865 uV 15:45:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -392.201 uVs 15:45:27 Integrated Voltage Measurement... 15:45:36 Voltage Offset Correction: v_off_ini = 2954.996 uV, v_off_fin = 2932.732 uV 15:45:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 409.909 uVs 15:45:36 Integrated Voltage Measurement... 15:45:45 Voltage Offset Correction: v_off_ini = 2934.257 uV, v_off_fin = 2931.142 uV 15:45:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.438 uVs 15:45:45 Integrated Voltage Measurement... 15:45:54 Voltage Offset Correction: v_off_ini = 2934.868 uV, v_off_fin = 2931.936 uV 15:45:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.120 uVs 15:45:54 Integrated Voltage Measurement... 15:46:03 Voltage Offset Correction: v_off_ini = 2938.498 uV, v_off_fin = 2901.634 uV 15:46:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -360.869 uVs 15:46:03 Integrated Voltage Measurement... 15:46:12 Voltage Offset Correction: v_off_ini = 2930.987 uV, v_off_fin = 2909.595 uV 15:46:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.224 uVs 15:46:14 I2Y Average and RMS of Measurements VT = -377.627 +- 17.768 uVs I2Y = -34.742 +- 1.635 uTm^2 15:46:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:46:23 Integrated Voltage Measurement... 15:46:32 Voltage Offset Correction: v_off_ini = 2911.261 uV, v_off_fin = 2941.111 uV 15:46:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -117.466 uVs 15:46:32 Integrated Voltage Measurement... 15:46:41 Voltage Offset Correction: v_off_ini = 2946.649 uV, v_off_fin = 2945.434 uV 15:46:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.396 uVs 15:46:41 Integrated Voltage Measurement... 15:46:50 Voltage Offset Correction: v_off_ini = 2930.873 uV, v_off_fin = 2937.993 uV 15:46:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.294 uVs 15:46:50 Integrated Voltage Measurement... 15:46:59 Voltage Offset Correction: v_off_ini = 2934.915 uV, v_off_fin = 2932.710 uV 15:46:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.188 uVs 15:46:59 Integrated Voltage Measurement... 15:47:08 Voltage Offset Correction: v_off_ini = 2927.072 uV, v_off_fin = 2909.922 uV 15:47:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -133.744 uVs 15:47:08 Integrated Voltage Measurement... 15:47:17 Voltage Offset Correction: v_off_ini = 2941.576 uV, v_off_fin = 2939.491 uV 15:47:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.739 uVs 15:47:22 I1X Average and RMS of Measurements VT = -125.638 +- 16.989 uVs I1X = 25.128 +- 3.398 uTm 15:47:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:47:28 Integrated Voltage Measurement... 15:47:37 Voltage Offset Correction: v_off_ini = 2913.696 uV, v_off_fin = 2924.672 uV 15:47:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.496 uVs 15:47:37 Integrated Voltage Measurement... 15:47:46 Voltage Offset Correction: v_off_ini = 2951.293 uV, v_off_fin = 2943.989 uV 15:47:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 272.739 uVs 15:47:46 Integrated Voltage Measurement... 15:47:55 Voltage Offset Correction: v_off_ini = 2935.891 uV, v_off_fin = 2947.706 uV 15:47:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.020 uVs 15:47:55 Integrated Voltage Measurement... 15:48:04 Voltage Offset Correction: v_off_ini = 3002.430 uV, v_off_fin = 2987.419 uV 15:48:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.448 uVs 15:48:04 Integrated Voltage Measurement... 15:48:13 Voltage Offset Correction: v_off_ini = 2984.315 uV, v_off_fin = 2984.998 uV 15:48:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.304 uVs 15:48:13 Integrated Voltage Measurement... 15:48:22 Voltage Offset Correction: v_off_ini = 2967.695 uV, v_off_fin = 2995.013 uV 15:48:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.639 uVs 15:48:27 I1Y Average and RMS of Measurements VT = -254.274 +- 13.147 uVs I1Y = -50.855 +- 2.629 uTm 15:48:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:48:34 Integrated Voltage Measurement... 15:48:43 Voltage Offset Correction: v_off_ini = 2945.753 uV, v_off_fin = 2958.028 uV 15:48:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -129.613 uVs 15:48:43 Integrated Voltage Measurement... 15:48:52 Voltage Offset Correction: v_off_ini = 2954.130 uV, v_off_fin = 2969.868 uV 15:48:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.654 uVs 15:48:52 Integrated Voltage Measurement... 15:49:01 Voltage Offset Correction: v_off_ini = 2942.576 uV, v_off_fin = 2925.559 uV 15:49:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -157.447 uVs 15:49:01 Integrated Voltage Measurement... 15:49:10 Voltage Offset Correction: v_off_ini = 2944.876 uV, v_off_fin = 2950.976 uV 15:49:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.171 uVs 15:49:10 Integrated Voltage Measurement... 15:49:19 Voltage Offset Correction: v_off_ini = 2984.863 uV, v_off_fin = 2963.405 uV 15:49:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -176.600 uVs 15:49:19 Integrated Voltage Measurement... 15:49:28 Voltage Offset Correction: v_off_ini = 2979.165 uV, v_off_fin = 2960.661 uV 15:49:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.749 uVs 15:49:31 I2X Average and RMS of Measurements VT = -145.039 +- 12.584 uVs I2X = 13.344 +- 1.157 uTm^2 15:49:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:49:38 Integrated Voltage Measurement... 15:49:47 Voltage Offset Correction: v_off_ini = 2955.644 uV, v_off_fin = 2962.900 uV 15:49:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -404.830 uVs 15:49:47 Integrated Voltage Measurement... 15:49:56 Voltage Offset Correction: v_off_ini = 2972.958 uV, v_off_fin = 2963.336 uV 15:49:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.327 uVs 15:49:57 Integrated Voltage Measurement... 15:50:06 Voltage Offset Correction: v_off_ini = 2956.634 uV, v_off_fin = 2989.189 uV 15:50:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -385.077 uVs 15:50:06 Integrated Voltage Measurement... 15:50:15 Voltage Offset Correction: v_off_ini = 2987.897 uV, v_off_fin = 2966.472 uV 15:50:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.350 uVs 15:50:15 Integrated Voltage Measurement... 15:50:24 Voltage Offset Correction: v_off_ini = 2953.727 uV, v_off_fin = 2975.014 uV 15:50:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -383.323 uVs 15:50:24 Integrated Voltage Measurement... 15:50:33 Voltage Offset Correction: v_off_ini = 2977.744 uV, v_off_fin = 3003.770 uV 15:50:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 379.435 uVs 15:50:35 I2Y Average and RMS of Measurements VT = -385.890 +- 7.319 uVs I2Y = -35.502 +- 0.673 uTm^2 15:50:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:50:47 Integrated Voltage Measurement... 15:50:56 Voltage Offset Correction: v_off_ini = 3018.332 uV, v_off_fin = 3008.271 uV 15:50:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -159.459 uVs 15:50:56 Integrated Voltage Measurement... 15:51:05 Voltage Offset Correction: v_off_ini = 2991.970 uV, v_off_fin = 3010.314 uV 15:51:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.408 uVs 15:51:05 Integrated Voltage Measurement... 15:51:14 Voltage Offset Correction: v_off_ini = 2981.006 uV, v_off_fin = 3021.054 uV 15:51:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.882 uVs 15:51:14 Integrated Voltage Measurement... 15:51:23 Voltage Offset Correction: v_off_ini = 3004.668 uV, v_off_fin = 2992.937 uV 15:51:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.441 uVs 15:51:23 Integrated Voltage Measurement... 15:51:32 Voltage Offset Correction: v_off_ini = 3010.352 uV, v_off_fin = 2997.671 uV 15:51:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -139.113 uVs 15:51:32 Integrated Voltage Measurement... 15:51:41 Voltage Offset Correction: v_off_ini = 2986.543 uV, v_off_fin = 2995.698 uV 15:51:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.728 uVs 15:51:45 I1X Average and RMS of Measurements VT = -136.672 +- 8.760 uVs I1X = 27.335 +- 1.752 uTm 15:51:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:51:52 Integrated Voltage Measurement... 15:52:01 Voltage Offset Correction: v_off_ini = 2979.646 uV, v_off_fin = 2966.678 uV 15:52:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.755 uVs 15:52:01 Integrated Voltage Measurement... 15:52:10 Voltage Offset Correction: v_off_ini = 2967.587 uV, v_off_fin = 2975.372 uV 15:52:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.012 uVs 15:52:10 Integrated Voltage Measurement... 15:52:19 Voltage Offset Correction: v_off_ini = 2999.864 uV, v_off_fin = 2991.960 uV 15:52:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.210 uVs 15:52:19 Integrated Voltage Measurement... 15:52:28 Voltage Offset Correction: v_off_ini = 3005.878 uV, v_off_fin = 2982.584 uV 15:52:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.113 uVs 15:52:28 Integrated Voltage Measurement... 15:52:37 Voltage Offset Correction: v_off_ini = 3005.690 uV, v_off_fin = 2999.800 uV 15:52:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.846 uVs 15:52:37 Integrated Voltage Measurement... 15:52:46 Voltage Offset Correction: v_off_ini = 2992.295 uV, v_off_fin = 3001.166 uV 15:52:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.688 uVs 15:52:50 I1Y Average and RMS of Measurements VT = -243.938 +- 6.401 uVs I1Y = -48.788 +- 1.279 uTm 15:52:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:52:55 Integrated Voltage Measurement... 15:53:04 Voltage Offset Correction: v_off_ini = 3002.445 uV, v_off_fin = 3003.224 uV 15:53:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.293 uVs 15:53:04 Integrated Voltage Measurement... 15:53:13 Voltage Offset Correction: v_off_ini = 2984.622 uV, v_off_fin = 2998.295 uV 15:53:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.705 uVs 15:53:13 Integrated Voltage Measurement... 15:53:22 Voltage Offset Correction: v_off_ini = 2984.870 uV, v_off_fin = 2962.812 uV 15:53:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.433 uVs 15:53:22 Integrated Voltage Measurement... 15:53:31 Voltage Offset Correction: v_off_ini = 2959.780 uV, v_off_fin = 2992.870 uV 15:53:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.757 uVs 15:53:31 Integrated Voltage Measurement... 15:53:40 Voltage Offset Correction: v_off_ini = 2988.727 uV, v_off_fin = 2958.948 uV 15:53:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.843 uVs 15:53:40 Integrated Voltage Measurement... 15:53:49 Voltage Offset Correction: v_off_ini = 2992.578 uV, v_off_fin = 2991.744 uV 15:53:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.664 uVs 15:53:52 I2X Average and RMS of Measurements VT = -125.949 +- 15.145 uVs I2X = 11.587 +- 1.393 uTm^2 15:53:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:53:57 Integrated Voltage Measurement... 15:54:06 Voltage Offset Correction: v_off_ini = 2962.445 uV, v_off_fin = 2999.564 uV 15:54:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -404.470 uVs 15:54:06 Integrated Voltage Measurement... 15:54:15 Voltage Offset Correction: v_off_ini = 2963.280 uV, v_off_fin = 3005.474 uV 15:54:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.611 uVs 15:54:15 Integrated Voltage Measurement... 15:54:24 Voltage Offset Correction: v_off_ini = 2971.740 uV, v_off_fin = 3000.362 uV 15:54:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -388.233 uVs 15:54:24 Integrated Voltage Measurement... 15:54:33 Voltage Offset Correction: v_off_ini = 2991.281 uV, v_off_fin = 3018.857 uV 15:54:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 417.641 uVs 15:54:33 Integrated Voltage Measurement... 15:54:42 Voltage Offset Correction: v_off_ini = 2991.164 uV, v_off_fin = 2976.937 uV 15:54:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -410.322 uVs 15:54:42 Integrated Voltage Measurement... 15:54:51 Voltage Offset Correction: v_off_ini = 2960.469 uV, v_off_fin = 2959.154 uV 15:54:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 404.889 uVs 15:54:53 I2Y Average and RMS of Measurements VT = -398.028 +- 10.420 uVs I2Y = -36.619 +- 0.959 uTm^2 15:54:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:55:02 Integrated Voltage Measurement... 15:55:11 Voltage Offset Correction: v_off_ini = 2989.896 uV, v_off_fin = 2985.577 uV 15:55:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.525 uVs 15:55:11 Integrated Voltage Measurement... 15:55:20 Voltage Offset Correction: v_off_ini = 3019.791 uV, v_off_fin = 3023.436 uV 15:55:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.318 uVs 15:55:20 Integrated Voltage Measurement... 15:55:29 Voltage Offset Correction: v_off_ini = 2999.493 uV, v_off_fin = 3001.854 uV 15:55:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.898 uVs 15:55:29 Integrated Voltage Measurement... 15:55:38 Voltage Offset Correction: v_off_ini = 3018.603 uV, v_off_fin = 3013.285 uV 15:55:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.746 uVs 15:55:38 Integrated Voltage Measurement... 15:55:47 Voltage Offset Correction: v_off_ini = 2985.937 uV, v_off_fin = 2965.629 uV 15:55:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.351 uVs 15:55:47 Integrated Voltage Measurement... 15:55:56 Voltage Offset Correction: v_off_ini = 3000.764 uV, v_off_fin = 3007.808 uV 15:55:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.145 uVs 15:56:00 I1X Average and RMS of Measurements VT = -94.164 +- 4.041 uVs I1X = 18.833 +- 0.808 uTm 15:56:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:56:07 Integrated Voltage Measurement... 15:56:16 Voltage Offset Correction: v_off_ini = 2974.218 uV, v_off_fin = 2972.868 uV 15:56:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.289 uVs 15:56:16 Integrated Voltage Measurement... 15:56:25 Voltage Offset Correction: v_off_ini = 3004.824 uV, v_off_fin = 2990.282 uV 15:56:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.190 uVs 15:56:25 Integrated Voltage Measurement... 15:56:34 Voltage Offset Correction: v_off_ini = 3007.668 uV, v_off_fin = 2986.058 uV 15:56:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.653 uVs 15:56:34 Integrated Voltage Measurement... 15:56:43 Voltage Offset Correction: v_off_ini = 2964.335 uV, v_off_fin = 2982.582 uV 15:56:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.470 uVs 15:56:43 Integrated Voltage Measurement... 15:56:52 Voltage Offset Correction: v_off_ini = 2949.345 uV, v_off_fin = 2952.390 uV 15:56:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.879 uVs 15:56:52 Integrated Voltage Measurement... 15:57:01 Voltage Offset Correction: v_off_ini = 2988.960 uV, v_off_fin = 2976.969 uV 15:57:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.580 uVs 15:57:05 I1Y Average and RMS of Measurements VT = -227.010 +- 12.734 uVs I1Y = -45.402 +- 2.547 uTm 15:57:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:57:10 Integrated Voltage Measurement... 15:57:19 Voltage Offset Correction: v_off_ini = 2985.172 uV, v_off_fin = 2969.321 uV 15:57:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.304 uVs 15:57:19 Integrated Voltage Measurement... 15:57:28 Voltage Offset Correction: v_off_ini = 2979.913 uV, v_off_fin = 3011.189 uV 15:57:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.851 uVs 15:57:28 Integrated Voltage Measurement... 15:57:37 Voltage Offset Correction: v_off_ini = 3015.183 uV, v_off_fin = 2987.281 uV 15:57:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.002 uVs 15:57:37 Integrated Voltage Measurement... 15:57:46 Voltage Offset Correction: v_off_ini = 2996.226 uV, v_off_fin = 3008.266 uV 15:57:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.173 uVs 15:57:46 Integrated Voltage Measurement... 15:57:55 Voltage Offset Correction: v_off_ini = 3033.503 uV, v_off_fin = 2990.051 uV 15:57:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.451 uVs 15:57:55 Integrated Voltage Measurement... 15:58:04 Voltage Offset Correction: v_off_ini = 3011.416 uV, v_off_fin = 3037.650 uV 15:58:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.725 uVs 15:58:06 I2X Average and RMS of Measurements VT = -119.251 +- 2.713 uVs I2X = 10.971 +- 0.250 uTm^2 15:58:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:58:12 Integrated Voltage Measurement... 15:58:21 Voltage Offset Correction: v_off_ini = 2997.942 uV, v_off_fin = 3010.435 uV 15:58:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -388.196 uVs 15:58:21 Integrated Voltage Measurement... 15:58:30 Voltage Offset Correction: v_off_ini = 3002.857 uV, v_off_fin = 2991.950 uV 15:58:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.918 uVs 15:58:30 Integrated Voltage Measurement... 15:58:39 Voltage Offset Correction: v_off_ini = 3004.090 uV, v_off_fin = 2989.983 uV 15:58:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.355 uVs 15:58:39 Integrated Voltage Measurement... 15:58:48 Voltage Offset Correction: v_off_ini = 3026.918 uV, v_off_fin = 3020.453 uV 15:58:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.448 uVs 15:58:48 Integrated Voltage Measurement... 15:58:57 Voltage Offset Correction: v_off_ini = 3002.147 uV, v_off_fin = 3004.396 uV 15:58:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.660 uVs 15:58:57 Integrated Voltage Measurement... 15:59:06 Voltage Offset Correction: v_off_ini = 2984.011 uV, v_off_fin = 2985.635 uV 15:59:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.456 uVs 15:59:08 I2Y Average and RMS of Measurements VT = -380.672 +- 9.113 uVs I2Y = -35.022 +- 0.838 uTm^2 15:59:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:16 Integrated Voltage Measurement... 15:59:25 Voltage Offset Correction: v_off_ini = 2958.380 uV, v_off_fin = 2970.021 uV 15:59:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.450 uVs 15:59:26 Integrated Voltage Measurement... 15:59:34 Voltage Offset Correction: v_off_ini = 2985.994 uV, v_off_fin = 2992.790 uV 15:59:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.203 uVs 15:59:35 Integrated Voltage Measurement... 15:59:43 Voltage Offset Correction: v_off_ini = 2991.175 uV, v_off_fin = 2985.270 uV 15:59:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.158 uVs 15:59:44 Integrated Voltage Measurement... 15:59:52 Voltage Offset Correction: v_off_ini = 2958.572 uV, v_off_fin = 2976.869 uV 15:59:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.201 uVs 15:59:53 Integrated Voltage Measurement... 16:00:02 Voltage Offset Correction: v_off_ini = 2943.244 uV, v_off_fin = 2992.825 uV 16:00:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.037 uVs 16:00:02 Integrated Voltage Measurement... 16:00:11 Voltage Offset Correction: v_off_ini = 2969.069 uV, v_off_fin = 3016.196 uV 16:00:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.052 uVs 16:00:15 I1X Average and RMS of Measurements VT = -101.683 +- 24.665 uVs I1X = 20.337 +- 4.933 uTm 16:00:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:22 Integrated Voltage Measurement... 16:00:30 Voltage Offset Correction: v_off_ini = 2986.445 uV, v_off_fin = 2952.099 uV 16:00:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.710 uVs 16:00:31 Integrated Voltage Measurement... 16:00:39 Voltage Offset Correction: v_off_ini = 2998.036 uV, v_off_fin = 2979.565 uV 16:00:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 252.444 uVs 16:00:40 Integrated Voltage Measurement... 16:00:48 Voltage Offset Correction: v_off_ini = 3013.916 uV, v_off_fin = 2989.464 uV 16:00:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.955 uVs 16:00:49 Integrated Voltage Measurement... 16:00:57 Voltage Offset Correction: v_off_ini = 2985.211 uV, v_off_fin = 3000.774 uV 16:00:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.879 uVs 16:00:58 Integrated Voltage Measurement... 16:01:06 Voltage Offset Correction: v_off_ini = 2961.280 uV, v_off_fin = 2957.401 uV 16:01:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.105 uVs 16:01:07 Integrated Voltage Measurement... 16:01:15 Voltage Offset Correction: v_off_ini = 2942.959 uV, v_off_fin = 2982.813 uV 16:01:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.566 uVs 16:01:20 I1Y Average and RMS of Measurements VT = -251.277 +- 5.643 uVs I1Y = -50.254 +- 1.127 uTm 16:01:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:25 Integrated Voltage Measurement... 16:01:34 Voltage Offset Correction: v_off_ini = 3008.387 uV, v_off_fin = 2987.401 uV 16:01:34 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -161.928 uVs 16:01:34 Integrated Voltage Measurement... 16:01:43 Voltage Offset Correction: v_off_ini = 2989.148 uV, v_off_fin = 2983.867 uV 16:01:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.104 uVs 16:01:43 Integrated Voltage Measurement... 16:01:52 Voltage Offset Correction: v_off_ini = 2950.146 uV, v_off_fin = 2951.324 uV 16:01:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.305 uVs 16:01:52 Integrated Voltage Measurement... 16:02:01 Voltage Offset Correction: v_off_ini = 2951.987 uV, v_off_fin = 2969.165 uV 16:02:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.356 uVs 16:02:01 Integrated Voltage Measurement... 16:02:10 Voltage Offset Correction: v_off_ini = 2993.136 uV, v_off_fin = 2974.332 uV 16:02:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.959 uVs 16:02:10 Integrated Voltage Measurement... 16:02:19 Voltage Offset Correction: v_off_ini = 2937.066 uV, v_off_fin = 2978.313 uV 16:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.230 uVs 16:02:21 I2X Average and RMS of Measurements VT = -149.147 +- 3.517 uVs I2X = 13.721 +- 0.323 uTm^2 16:02:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:26 Integrated Voltage Measurement... 16:02:35 Voltage Offset Correction: v_off_ini = 2904.685 uV, v_off_fin = 2908.162 uV 16:02:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -373.053 uVs 16:02:35 Integrated Voltage Measurement... 16:02:44 Voltage Offset Correction: v_off_ini = 2917.644 uV, v_off_fin = 2923.596 uV 16:02:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.133 uVs 16:02:45 Integrated Voltage Measurement... 16:02:53 Voltage Offset Correction: v_off_ini = 2902.417 uV, v_off_fin = 2907.974 uV 16:02:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.411 uVs 16:02:54 Integrated Voltage Measurement... 16:03:03 Voltage Offset Correction: v_off_ini = 2903.756 uV, v_off_fin = 2893.437 uV 16:03:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 409.696 uVs 16:03:03 Integrated Voltage Measurement... 16:03:12 Voltage Offset Correction: v_off_ini = 2947.506 uV, v_off_fin = 2927.805 uV 16:03:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -400.764 uVs 16:03:12 Integrated Voltage Measurement... 16:03:21 Voltage Offset Correction: v_off_ini = 2883.136 uV, v_off_fin = 2939.095 uV 16:03:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 375.491 uVs 16:03:23 I2Y Average and RMS of Measurements VT = -385.758 +- 13.965 uVs I2Y = -35.490 +- 1.285 uTm^2 16:03:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:03:31 Integrated Voltage Measurement... 16:03:40 Voltage Offset Correction: v_off_ini = 2914.333 uV, v_off_fin = 2939.975 uV 16:03:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.039 uVs 16:03:40 Integrated Voltage Measurement... 16:03:49 Voltage Offset Correction: v_off_ini = 2933.454 uV, v_off_fin = 2940.928 uV 16:03:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.439 uVs 16:03:49 Integrated Voltage Measurement... 16:03:58 Voltage Offset Correction: v_off_ini = 2917.286 uV, v_off_fin = 2888.110 uV 16:03:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.837 uVs 16:03:58 Integrated Voltage Measurement... 16:04:07 Voltage Offset Correction: v_off_ini = 2931.887 uV, v_off_fin = 2928.074 uV 16:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.016 uVs 16:04:07 Integrated Voltage Measurement... 16:04:16 Voltage Offset Correction: v_off_ini = 2914.289 uV, v_off_fin = 2892.305 uV 16:04:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.374 uVs 16:04:16 Integrated Voltage Measurement... 16:04:25 Voltage Offset Correction: v_off_ini = 2945.957 uV, v_off_fin = 2944.026 uV 16:04:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.980 uVs 16:04:30 I1X Average and RMS of Measurements VT = -108.447 +- 9.343 uVs I1X = 21.690 +- 1.868 uTm 16:04:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:04:36 Integrated Voltage Measurement... 16:04:45 Voltage Offset Correction: v_off_ini = 2904.276 uV, v_off_fin = 2884.728 uV 16:04:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -245.739 uVs 16:04:45 Integrated Voltage Measurement... 16:04:54 Voltage Offset Correction: v_off_ini = 2887.957 uV, v_off_fin = 2911.984 uV 16:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.075 uVs 16:04:54 Integrated Voltage Measurement... 16:05:03 Voltage Offset Correction: v_off_ini = 2927.720 uV, v_off_fin = 2899.879 uV 16:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.107 uVs 16:05:03 Integrated Voltage Measurement... 16:05:12 Voltage Offset Correction: v_off_ini = 2905.570 uV, v_off_fin = 2916.799 uV 16:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.720 uVs 16:05:12 Integrated Voltage Measurement... 16:05:21 Voltage Offset Correction: v_off_ini = 2899.315 uV, v_off_fin = 2901.210 uV 16:05:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -257.791 uVs 16:05:21 Integrated Voltage Measurement... 16:05:30 Voltage Offset Correction: v_off_ini = 2918.620 uV, v_off_fin = 2897.211 uV 16:05:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 269.057 uVs 16:05:35 I1Y Average and RMS of Measurements VT = -241.748 +- 20.405 uVs I1Y = -48.349 +- 4.080 uTm 16:05:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:05:40 Integrated Voltage Measurement... 16:05:49 Voltage Offset Correction: v_off_ini = 2923.291 uV, v_off_fin = 2907.937 uV 16:05:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.012 uVs 16:05:49 Integrated Voltage Measurement... 16:05:58 Voltage Offset Correction: v_off_ini = 2938.749 uV, v_off_fin = 2937.063 uV 16:05:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.704 uVs 16:05:58 Integrated Voltage Measurement... 16:06:07 Voltage Offset Correction: v_off_ini = 2909.217 uV, v_off_fin = 2887.664 uV 16:06:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.078 uVs 16:06:07 Integrated Voltage Measurement... 16:06:16 Voltage Offset Correction: v_off_ini = 2908.520 uV, v_off_fin = 2924.931 uV 16:06:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.555 uVs 16:06:16 Integrated Voltage Measurement... 16:06:25 Voltage Offset Correction: v_off_ini = 2921.541 uV, v_off_fin = 2933.427 uV 16:06:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.572 uVs 16:06:25 Integrated Voltage Measurement... 16:06:34 Voltage Offset Correction: v_off_ini = 2921.012 uV, v_off_fin = 2914.310 uV 16:06:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.987 uVs 16:06:36 I2X Average and RMS of Measurements VT = -122.985 +- 7.582 uVs I2X = 11.315 +- 0.698 uTm^2 16:06:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:06:41 Integrated Voltage Measurement... 16:06:50 Voltage Offset Correction: v_off_ini = 2924.533 uV, v_off_fin = 2922.681 uV 16:06:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -412.687 uVs 16:06:50 Integrated Voltage Measurement... 16:06:59 Voltage Offset Correction: v_off_ini = 2891.435 uV, v_off_fin = 2894.199 uV 16:06:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.268 uVs 16:06:59 Integrated Voltage Measurement... 16:07:08 Voltage Offset Correction: v_off_ini = 2897.762 uV, v_off_fin = 2923.823 uV 16:07:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.387 uVs 16:07:08 Integrated Voltage Measurement... 16:07:17 Voltage Offset Correction: v_off_ini = 2963.421 uV, v_off_fin = 2946.005 uV 16:07:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.875 uVs 16:07:17 Integrated Voltage Measurement... 16:07:26 Voltage Offset Correction: v_off_ini = 2930.941 uV, v_off_fin = 2970.678 uV 16:07:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.063 uVs 16:07:26 Integrated Voltage Measurement... 16:07:35 Voltage Offset Correction: v_off_ini = 2967.984 uV, v_off_fin = 2949.818 uV 16:07:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.411 uVs 16:07:38 I2Y Average and RMS of Measurements VT = -379.115 +- 13.028 uVs I2Y = -34.879 +- 1.199 uTm^2 16:07:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:07:46 Integrated Voltage Measurement... 16:07:55 Voltage Offset Correction: v_off_ini = 2947.780 uV, v_off_fin = 2924.406 uV 16:07:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -94.475 uVs 16:07:55 Integrated Voltage Measurement... 16:08:04 Voltage Offset Correction: v_off_ini = 2948.027 uV, v_off_fin = 2929.746 uV 16:08:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.705 uVs 16:08:04 Integrated Voltage Measurement... 16:08:13 Voltage Offset Correction: v_off_ini = 2884.013 uV, v_off_fin = 2956.015 uV 16:08:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.664 uVs 16:08:13 Integrated Voltage Measurement... 16:08:22 Voltage Offset Correction: v_off_ini = 2970.023 uV, v_off_fin = 2976.561 uV 16:08:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.804 uVs 16:08:22 Integrated Voltage Measurement... 16:08:31 Voltage Offset Correction: v_off_ini = 2958.172 uV, v_off_fin = 2962.844 uV 16:08:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.182 uVs 16:08:31 Integrated Voltage Measurement... 16:08:40 Voltage Offset Correction: v_off_ini = 2931.804 uV, v_off_fin = 2945.777 uV 16:08:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.933 uVs 16:08:44 I1X Average and RMS of Measurements VT = -87.627 +- 6.001 uVs I1X = 17.526 +- 1.200 uTm 16:08:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:08:51 Integrated Voltage Measurement... 16:09:00 Voltage Offset Correction: v_off_ini = 2979.581 uV, v_off_fin = 2965.182 uV 16:09:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.889 uVs 16:09:00 Integrated Voltage Measurement... 16:09:09 Voltage Offset Correction: v_off_ini = 2958.155 uV, v_off_fin = 2991.387 uV 16:09:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 240.053 uVs 16:09:09 Integrated Voltage Measurement... 16:09:18 Voltage Offset Correction: v_off_ini = 3017.462 uV, v_off_fin = 3003.794 uV 16:09:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -278.298 uVs 16:09:18 Integrated Voltage Measurement... 16:09:27 Voltage Offset Correction: v_off_ini = 2951.373 uV, v_off_fin = 2962.245 uV 16:09:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.619 uVs 16:09:27 Integrated Voltage Measurement... 16:09:36 Voltage Offset Correction: v_off_ini = 2938.063 uV, v_off_fin = 2949.527 uV 16:09:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -240.142 uVs 16:09:36 Integrated Voltage Measurement... 16:09:45 Voltage Offset Correction: v_off_ini = 2969.027 uV, v_off_fin = 2980.404 uV 16:09:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.440 uVs 16:09:49 I1Y Average and RMS of Measurements VT = -239.574 +- 7.364 uVs I1Y = -47.910 +- 1.473 uTm 16:09:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:09:54 Integrated Voltage Measurement... 16:10:03 Voltage Offset Correction: v_off_ini = 2988.862 uV, v_off_fin = 2996.684 uV 16:10:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.325 uVs 16:10:03 Integrated Voltage Measurement... 16:10:12 Voltage Offset Correction: v_off_ini = 2972.070 uV, v_off_fin = 2996.674 uV 16:10:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.870 uVs 16:10:12 Integrated Voltage Measurement... 16:10:21 Voltage Offset Correction: v_off_ini = 2993.821 uV, v_off_fin = 2958.446 uV 16:10:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.928 uVs 16:10:22 Integrated Voltage Measurement... 16:10:30 Voltage Offset Correction: v_off_ini = 2947.079 uV, v_off_fin = 2984.231 uV 16:10:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.269 uVs 16:10:31 Integrated Voltage Measurement... 16:10:40 Voltage Offset Correction: v_off_ini = 2965.038 uV, v_off_fin = 2964.348 uV 16:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.391 uVs 16:10:40 Integrated Voltage Measurement... 16:10:49 Voltage Offset Correction: v_off_ini = 2981.919 uV, v_off_fin = 2998.386 uV 16:10:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.691 uVs 16:10:51 I2X Average and RMS of Measurements VT = -118.912 +- 10.901 uVs I2X = 10.940 +- 1.003 uTm^2 16:10:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:10:56 Integrated Voltage Measurement... 16:11:05 Voltage Offset Correction: v_off_ini = 2954.334 uV, v_off_fin = 2962.975 uV 16:11:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -383.421 uVs 16:11:05 Integrated Voltage Measurement... 16:11:14 Voltage Offset Correction: v_off_ini = 2991.693 uV, v_off_fin = 2983.284 uV 16:11:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.921 uVs 16:11:14 Integrated Voltage Measurement... 16:11:23 Voltage Offset Correction: v_off_ini = 2988.225 uV, v_off_fin = 2980.075 uV 16:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -407.356 uVs 16:11:23 Integrated Voltage Measurement... 16:11:32 Voltage Offset Correction: v_off_ini = 2988.861 uV, v_off_fin = 2976.185 uV 16:11:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 394.560 uVs 16:11:32 Integrated Voltage Measurement... 16:11:41 Voltage Offset Correction: v_off_ini = 2986.186 uV, v_off_fin = 2975.617 uV 16:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.922 uVs 16:11:41 Integrated Voltage Measurement... 16:11:50 Voltage Offset Correction: v_off_ini = 2967.255 uV, v_off_fin = 2992.058 uV 16:11:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 401.308 uVs 16:11:53 I2Y Average and RMS of Measurements VT = -387.081 +- 12.245 uVs I2Y = -35.611 +- 1.127 uTm^2 16:12:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:12:13 Integrated Voltage Measurement... 16:12:22 Voltage Offset Correction: v_off_ini = 3014.927 uV, v_off_fin = 3040.255 uV 16:12:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.029 uVs 16:12:22 Integrated Voltage Measurement... 16:12:31 Voltage Offset Correction: v_off_ini = 3052.340 uV, v_off_fin = 3072.992 uV 16:12:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.561 uVs 16:12:31 Integrated Voltage Measurement... 16:12:40 Voltage Offset Correction: v_off_ini = 2996.177 uV, v_off_fin = 3019.045 uV 16:12:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.862 uVs 16:12:40 Integrated Voltage Measurement... 16:12:49 Voltage Offset Correction: v_off_ini = 3022.686 uV, v_off_fin = 2996.767 uV 16:12:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.039 uVs 16:12:49 Integrated Voltage Measurement... 16:12:58 Voltage Offset Correction: v_off_ini = 2998.094 uV, v_off_fin = 2976.844 uV 16:12:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.548 uVs 16:12:58 Integrated Voltage Measurement... 16:13:07 Voltage Offset Correction: v_off_ini = 3013.057 uV, v_off_fin = 3015.910 uV 16:13:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.545 uVs 16:13:11 I1X Average and RMS of Measurements VT = -107.097 +- 15.139 uVs I1X = 21.420 +- 3.027 uTm 16:13:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:13:18 Integrated Voltage Measurement... 16:13:27 Voltage Offset Correction: v_off_ini = 3022.132 uV, v_off_fin = 3019.571 uV 16:13:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -187.367 uVs 16:13:27 Integrated Voltage Measurement... 16:13:36 Voltage Offset Correction: v_off_ini = 3001.646 uV, v_off_fin = 3057.537 uV 16:13:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.014 uVs 16:13:36 Integrated Voltage Measurement... 16:13:45 Voltage Offset Correction: v_off_ini = 3029.201 uV, v_off_fin = 3029.086 uV 16:13:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.852 uVs 16:13:45 Integrated Voltage Measurement... 16:13:54 Voltage Offset Correction: v_off_ini = 3020.928 uV, v_off_fin = 3033.764 uV 16:13:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.047 uVs 16:13:54 Integrated Voltage Measurement... 16:14:03 Voltage Offset Correction: v_off_ini = 3023.411 uV, v_off_fin = 3051.725 uV 16:14:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.609 uVs 16:14:03 Integrated Voltage Measurement... 16:14:12 Voltage Offset Correction: v_off_ini = 3036.032 uV, v_off_fin = 3040.861 uV 16:14:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.576 uVs 16:14:16 I1Y Average and RMS of Measurements VT = -200.744 +- 8.740 uVs I1Y = -40.149 +- 1.747 uTm 16:14:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:14:24 Integrated Voltage Measurement... 16:14:33 Voltage Offset Correction: v_off_ini = 3045.008 uV, v_off_fin = 3040.393 uV 16:14:33 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -108.324 uVs 16:14:33 Integrated Voltage Measurement... 16:14:42 Voltage Offset Correction: v_off_ini = 3018.523 uV, v_off_fin = 3040.415 uV 16:14:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.534 uVs 16:14:42 Integrated Voltage Measurement... 16:14:51 Voltage Offset Correction: v_off_ini = 3016.468 uV, v_off_fin = 3015.993 uV 16:14:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.771 uVs 16:14:51 Integrated Voltage Measurement... 16:15:00 Voltage Offset Correction: v_off_ini = 3054.481 uV, v_off_fin = 3063.638 uV 16:15:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.812 uVs 16:15:00 Integrated Voltage Measurement... 16:15:09 Voltage Offset Correction: v_off_ini = 3080.032 uV, v_off_fin = 3056.547 uV 16:15:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.604 uVs 16:15:09 Integrated Voltage Measurement... 16:15:18 Voltage Offset Correction: v_off_ini = 3016.193 uV, v_off_fin = 3043.332 uV 16:15:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 94.783 uVs 16:15:20 I2X Average and RMS of Measurements VT = -111.805 +- 5.581 uVs I2X = 10.286 +- 0.514 uTm^2 16:15:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:15:28 Integrated Voltage Measurement... 16:15:37 Voltage Offset Correction: v_off_ini = 3028.064 uV, v_off_fin = 3029.837 uV 16:15:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.315 uVs 16:15:37 Integrated Voltage Measurement... 16:15:46 Voltage Offset Correction: v_off_ini = 3005.612 uV, v_off_fin = 3001.161 uV 16:15:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.758 uVs 16:15:46 Integrated Voltage Measurement... 16:15:55 Voltage Offset Correction: v_off_ini = 3033.988 uV, v_off_fin = 3015.178 uV 16:15:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.900 uVs 16:15:55 Integrated Voltage Measurement... 16:16:04 Voltage Offset Correction: v_off_ini = 3062.822 uV, v_off_fin = 3034.878 uV 16:16:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.565 uVs 16:16:04 Integrated Voltage Measurement... 16:16:13 Voltage Offset Correction: v_off_ini = 3022.913 uV, v_off_fin = 2992.546 uV 16:16:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.787 uVs 16:16:13 Integrated Voltage Measurement... 16:16:22 Voltage Offset Correction: v_off_ini = 3042.641 uV, v_off_fin = 3010.590 uV 16:16:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.991 uVs 16:16:24 I2Y Average and RMS of Measurements VT = -336.219 +- 14.676 uVs I2Y = -30.932 +- 1.350 uTm^2 16:16:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:16:33 Integrated Voltage Measurement... 16:16:42 Voltage Offset Correction: v_off_ini = 3046.722 uV, v_off_fin = 3054.233 uV 16:16:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.786 uVs 16:16:42 Integrated Voltage Measurement... 16:16:51 Voltage Offset Correction: v_off_ini = 3018.736 uV, v_off_fin = 3022.668 uV 16:16:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.604 uVs 16:16:51 Integrated Voltage Measurement... 16:17:00 Voltage Offset Correction: v_off_ini = 3041.590 uV, v_off_fin = 3053.849 uV 16:17:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.390 uVs 16:17:00 Integrated Voltage Measurement... 16:17:09 Voltage Offset Correction: v_off_ini = 3025.259 uV, v_off_fin = 3044.871 uV 16:17:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.254 uVs 16:17:09 Integrated Voltage Measurement... 16:17:18 Voltage Offset Correction: v_off_ini = 3034.340 uV, v_off_fin = 3039.123 uV 16:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.035 uVs 16:17:18 Integrated Voltage Measurement... 16:17:27 Voltage Offset Correction: v_off_ini = 3020.644 uV, v_off_fin = 3030.064 uV 16:17:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.380 uVs 16:17:32 I1X Average and RMS of Measurements VT = -127.242 +- 9.563 uVs I1X = 25.449 +- 1.912 uTm 16:17:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:17:38 Integrated Voltage Measurement... 16:17:47 Voltage Offset Correction: v_off_ini = 3010.936 uV, v_off_fin = 2993.393 uV 16:17:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.568 uVs 16:17:47 Integrated Voltage Measurement... 16:17:56 Voltage Offset Correction: v_off_ini = 3042.245 uV, v_off_fin = 3057.034 uV 16:17:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.500 uVs 16:17:56 Integrated Voltage Measurement... 16:18:05 Voltage Offset Correction: v_off_ini = 3022.204 uV, v_off_fin = 3034.712 uV 16:18:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.865 uVs 16:18:05 Integrated Voltage Measurement... 16:18:14 Voltage Offset Correction: v_off_ini = 3031.155 uV, v_off_fin = 3014.295 uV 16:18:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.724 uVs 16:18:14 Integrated Voltage Measurement... 16:18:23 Voltage Offset Correction: v_off_ini = 2979.440 uV, v_off_fin = 2994.004 uV 16:18:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.292 uVs 16:18:23 Integrated Voltage Measurement... 16:18:32 Voltage Offset Correction: v_off_ini = 2993.566 uV, v_off_fin = 2989.889 uV 16:18:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.644 uVs 16:18:37 I1Y Average and RMS of Measurements VT = -212.266 +- 7.973 uVs I1Y = -42.453 +- 1.595 uTm 16:18:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:18:44 Integrated Voltage Measurement... 16:18:53 Voltage Offset Correction: v_off_ini = 3034.365 uV, v_off_fin = 3018.799 uV 16:18:53 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -106.615 uVs 16:18:53 Integrated Voltage Measurement... 16:19:02 Voltage Offset Correction: v_off_ini = 3000.472 uV, v_off_fin = 3037.953 uV 16:19:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.975 uVs 16:19:02 Integrated Voltage Measurement... 16:19:11 Voltage Offset Correction: v_off_ini = 3035.313 uV, v_off_fin = 3033.735 uV 16:19:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.611 uVs 16:19:11 Integrated Voltage Measurement... 16:19:20 Voltage Offset Correction: v_off_ini = 3037.892 uV, v_off_fin = 3048.605 uV 16:19:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.710 uVs 16:19:20 Integrated Voltage Measurement... 16:19:29 Voltage Offset Correction: v_off_ini = 2999.987 uV, v_off_fin = 3001.888 uV 16:19:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.184 uVs 16:19:29 Integrated Voltage Measurement... 16:19:38 Voltage Offset Correction: v_off_ini = 3014.183 uV, v_off_fin = 3005.196 uV 16:19:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.938 uVs 16:19:41 I2X Average and RMS of Measurements VT = -117.006 +- 15.111 uVs I2X = 10.764 +- 1.390 uTm^2 16:19:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:19:48 Integrated Voltage Measurement... 16:19:57 Voltage Offset Correction: v_off_ini = 3003.198 uV, v_off_fin = 2997.652 uV 16:19:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.199 uVs 16:19:57 Integrated Voltage Measurement... 16:20:06 Voltage Offset Correction: v_off_ini = 3018.531 uV, v_off_fin = 2987.903 uV 16:20:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.570 uVs 16:20:07 Integrated Voltage Measurement... 16:20:16 Voltage Offset Correction: v_off_ini = 2994.855 uV, v_off_fin = 3004.013 uV 16:20:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -347.142 uVs 16:20:16 Integrated Voltage Measurement... 16:20:25 Voltage Offset Correction: v_off_ini = 2985.797 uV, v_off_fin = 2988.065 uV 16:20:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.174 uVs 16:20:25 Integrated Voltage Measurement... 16:20:34 Voltage Offset Correction: v_off_ini = 3000.085 uV, v_off_fin = 2971.804 uV 16:20:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -377.814 uVs 16:20:34 Integrated Voltage Measurement... 16:20:43 Voltage Offset Correction: v_off_ini = 2977.010 uV, v_off_fin = 2977.072 uV 16:20:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.938 uVs 16:20:45 I2Y Average and RMS of Measurements VT = -341.306 +- 16.268 uVs I2Y = -31.400 +- 1.497 uTm^2 16:20:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:20:54 Integrated Voltage Measurement... 16:21:03 Voltage Offset Correction: v_off_ini = 2990.023 uV, v_off_fin = 3009.691 uV 16:21:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -164.908 uVs 16:21:03 Integrated Voltage Measurement... 16:21:12 Voltage Offset Correction: v_off_ini = 2996.703 uV, v_off_fin = 3015.865 uV 16:21:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.932 uVs 16:21:12 Integrated Voltage Measurement... 16:21:21 Voltage Offset Correction: v_off_ini = 3022.683 uV, v_off_fin = 2988.288 uV 16:21:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.121 uVs 16:21:21 Integrated Voltage Measurement... 16:21:30 Voltage Offset Correction: v_off_ini = 2991.131 uV, v_off_fin = 2971.627 uV 16:21:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.309 uVs 16:21:30 Integrated Voltage Measurement... 16:21:39 Voltage Offset Correction: v_off_ini = 2986.969 uV, v_off_fin = 2984.767 uV 16:21:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.341 uVs 16:21:39 Integrated Voltage Measurement... 16:21:48 Voltage Offset Correction: v_off_ini = 2962.151 uV, v_off_fin = 2988.312 uV 16:21:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.578 uVs 16:21:52 I1X Average and RMS of Measurements VT = -122.698 +- 27.765 uVs I1X = 24.540 +- 5.553 uTm 16:21:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:59 Integrated Voltage Measurement... 16:22:08 Voltage Offset Correction: v_off_ini = 2960.575 uV, v_off_fin = 2996.892 uV 16:22:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.428 uVs 16:22:08 Integrated Voltage Measurement... 16:22:17 Voltage Offset Correction: v_off_ini = 2991.631 uV, v_off_fin = 2993.983 uV 16:22:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.858 uVs 16:22:17 Integrated Voltage Measurement... 16:22:26 Voltage Offset Correction: v_off_ini = 2991.057 uV, v_off_fin = 2985.289 uV 16:22:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.447 uVs 16:22:26 Integrated Voltage Measurement... 16:22:35 Voltage Offset Correction: v_off_ini = 3032.163 uV, v_off_fin = 3065.593 uV 16:22:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.874 uVs 16:22:35 Integrated Voltage Measurement... 16:22:44 Voltage Offset Correction: v_off_ini = 3021.530 uV, v_off_fin = 2988.544 uV 16:22:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.825 uVs 16:22:44 Integrated Voltage Measurement... 16:22:53 Voltage Offset Correction: v_off_ini = 3030.336 uV, v_off_fin = 3043.551 uV 16:22:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.724 uVs 16:22:57 I1Y Average and RMS of Measurements VT = -235.193 +- 9.282 uVs I1Y = -47.039 +- 1.856 uTm 16:23:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:23:05 Integrated Voltage Measurement... 16:23:14 Voltage Offset Correction: v_off_ini = 2990.507 uV, v_off_fin = 2997.908 uV 16:23:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -122.367 uVs 16:23:14 Integrated Voltage Measurement... 16:23:23 Voltage Offset Correction: v_off_ini = 3033.014 uV, v_off_fin = 3055.213 uV 16:23:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.290 uVs 16:23:23 Integrated Voltage Measurement... 16:23:32 Voltage Offset Correction: v_off_ini = 3045.926 uV, v_off_fin = 3045.985 uV 16:23:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.940 uVs 16:23:32 Integrated Voltage Measurement... 16:23:41 Voltage Offset Correction: v_off_ini = 3035.974 uV, v_off_fin = 3014.475 uV 16:23:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.403 uVs 16:23:41 Integrated Voltage Measurement... 16:23:50 Voltage Offset Correction: v_off_ini = 2998.662 uV, v_off_fin = 2987.298 uV 16:23:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.016 uVs 16:23:50 Integrated Voltage Measurement... 16:23:59 Voltage Offset Correction: v_off_ini = 3008.193 uV, v_off_fin = 3050.746 uV 16:23:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.738 uVs 16:24:01 I2X Average and RMS of Measurements VT = -128.292 +- 15.330 uVs I2X = 11.803 +- 1.411 uTm^2 16:24:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:24:09 Integrated Voltage Measurement... 16:24:18 Voltage Offset Correction: v_off_ini = 3012.529 uV, v_off_fin = 2989.847 uV 16:24:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.799 uVs 16:24:18 Integrated Voltage Measurement... 16:24:27 Voltage Offset Correction: v_off_ini = 2999.584 uV, v_off_fin = 3041.744 uV 16:24:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.214 uVs 16:24:27 Integrated Voltage Measurement... 16:24:36 Voltage Offset Correction: v_off_ini = 3015.306 uV, v_off_fin = 3008.043 uV 16:24:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.743 uVs 16:24:36 Integrated Voltage Measurement... 16:24:45 Voltage Offset Correction: v_off_ini = 2988.243 uV, v_off_fin = 2987.116 uV 16:24:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.650 uVs 16:24:45 Integrated Voltage Measurement... 16:24:54 Voltage Offset Correction: v_off_ini = 2984.936 uV, v_off_fin = 2984.412 uV 16:24:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.490 uVs 16:24:54 Integrated Voltage Measurement... 16:25:03 Voltage Offset Correction: v_off_ini = 2978.465 uV, v_off_fin = 3033.855 uV 16:25:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.130 uVs 16:25:06 I2Y Average and RMS of Measurements VT = -359.004 +- 6.391 uVs I2Y = -33.028 +- 0.588 uTm^2 16:25:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:25:15 Integrated Voltage Measurement... 16:25:24 Voltage Offset Correction: v_off_ini = 3063.400 uV, v_off_fin = 3039.213 uV 16:25:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -134.772 uVs 16:25:24 Integrated Voltage Measurement... 16:25:33 Voltage Offset Correction: v_off_ini = 3007.049 uV, v_off_fin = 3043.902 uV 16:25:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.261 uVs 16:25:33 Integrated Voltage Measurement... 16:25:42 Voltage Offset Correction: v_off_ini = 3008.137 uV, v_off_fin = 3032.687 uV 16:25:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.319 uVs 16:25:42 Integrated Voltage Measurement... 16:25:51 Voltage Offset Correction: v_off_ini = 3060.395 uV, v_off_fin = 3026.859 uV 16:25:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.047 uVs 16:25:51 Integrated Voltage Measurement... 16:26:00 Voltage Offset Correction: v_off_ini = 3046.787 uV, v_off_fin = 3026.199 uV 16:26:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.621 uVs 16:26:00 Integrated Voltage Measurement... 16:26:09 Voltage Offset Correction: v_off_ini = 3024.801 uV, v_off_fin = 3025.346 uV 16:26:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.481 uVs 16:26:13 I1X Average and RMS of Measurements VT = -131.583 +- 7.014 uVs I1X = 26.318 +- 1.402 uTm 16:26:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:26:20 Integrated Voltage Measurement... 16:26:29 Voltage Offset Correction: v_off_ini = 3006.118 uV, v_off_fin = 3029.229 uV 16:26:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -193.144 uVs 16:26:29 Integrated Voltage Measurement... 16:26:37 Voltage Offset Correction: v_off_ini = 3073.026 uV, v_off_fin = 3058.437 uV 16:26:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.026 uVs 16:26:38 Integrated Voltage Measurement... 16:26:46 Voltage Offset Correction: v_off_ini = 3033.503 uV, v_off_fin = 3024.495 uV 16:26:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.572 uVs 16:26:47 Integrated Voltage Measurement... 16:26:55 Voltage Offset Correction: v_off_ini = 3013.956 uV, v_off_fin = 3011.906 uV 16:26:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.781 uVs 16:26:56 Integrated Voltage Measurement... 16:27:04 Voltage Offset Correction: v_off_ini = 3028.412 uV, v_off_fin = 3024.564 uV 16:27:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.112 uVs 16:27:05 Integrated Voltage Measurement... 16:27:13 Voltage Offset Correction: v_off_ini = 3008.989 uV, v_off_fin = 3064.812 uV 16:27:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.113 uVs 16:27:18 I1Y Average and RMS of Measurements VT = -222.458 +- 3.658 uVs I1Y = -44.492 +- 0.731 uTm 16:27:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:27:25 Integrated Voltage Measurement... 16:27:34 Voltage Offset Correction: v_off_ini = 3034.427 uV, v_off_fin = 3050.690 uV 16:27:34 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -117.410 uVs 16:27:34 Integrated Voltage Measurement... 16:27:43 Voltage Offset Correction: v_off_ini = 3063.428 uV, v_off_fin = 3066.527 uV 16:27:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.642 uVs 16:27:43 Integrated Voltage Measurement... 16:27:52 Voltage Offset Correction: v_off_ini = 3050.552 uV, v_off_fin = 3049.595 uV 16:27:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.355 uVs 16:27:52 Integrated Voltage Measurement... 16:28:01 Voltage Offset Correction: v_off_ini = 3045.260 uV, v_off_fin = 3021.223 uV 16:28:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.082 uVs 16:28:02 Integrated Voltage Measurement... 16:28:10 Voltage Offset Correction: v_off_ini = 3022.841 uV, v_off_fin = 3039.951 uV 16:28:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.902 uVs 16:28:11 Integrated Voltage Measurement... 16:28:20 Voltage Offset Correction: v_off_ini = 3028.174 uV, v_off_fin = 3026.819 uV 16:28:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.665 uVs 16:28:22 I2X Average and RMS of Measurements VT = -119.676 +- 12.683 uVs I2X = 11.010 +- 1.167 uTm^2 16:28:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:28:30 Integrated Voltage Measurement... 16:28:39 Voltage Offset Correction: v_off_ini = 3008.838 uV, v_off_fin = 3029.363 uV 16:28:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -392.608 uVs 16:28:39 Integrated Voltage Measurement... 16:28:48 Voltage Offset Correction: v_off_ini = 3045.466 uV, v_off_fin = 3045.616 uV 16:28:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.520 uVs 16:28:48 Integrated Voltage Measurement... 16:28:57 Voltage Offset Correction: v_off_ini = 3039.603 uV, v_off_fin = 3020.641 uV 16:28:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -382.396 uVs 16:28:57 Integrated Voltage Measurement... 16:29:06 Voltage Offset Correction: v_off_ini = 3043.224 uV, v_off_fin = 3065.353 uV 16:29:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.024 uVs 16:29:06 Integrated Voltage Measurement... 16:29:15 Voltage Offset Correction: v_off_ini = 3053.455 uV, v_off_fin = 3085.729 uV 16:29:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -394.828 uVs 16:29:15 Integrated Voltage Measurement... 16:29:24 Voltage Offset Correction: v_off_ini = 3104.664 uV, v_off_fin = 3037.371 uV 16:29:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.895 uVs 16:29:26 I2Y Average and RMS of Measurements VT = -370.045 +- 7.368 uVs I2Y = -34.044 +- 0.678 uTm^2 16:29:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:29:35 Integrated Voltage Measurement... 16:29:44 Voltage Offset Correction: v_off_ini = 3047.574 uV, v_off_fin = 3064.702 uV 16:29:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.710 uVs 16:29:44 Integrated Voltage Measurement... 16:29:53 Voltage Offset Correction: v_off_ini = 3073.603 uV, v_off_fin = 3091.254 uV 16:29:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.572 uVs 16:29:53 Integrated Voltage Measurement... 16:30:02 Voltage Offset Correction: v_off_ini = 3099.648 uV, v_off_fin = 3067.504 uV 16:30:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.449 uVs 16:30:02 Integrated Voltage Measurement... 16:30:11 Voltage Offset Correction: v_off_ini = 3060.881 uV, v_off_fin = 3076.623 uV 16:30:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.214 uVs 16:30:11 Integrated Voltage Measurement... 16:30:20 Voltage Offset Correction: v_off_ini = 3093.351 uV, v_off_fin = 3086.673 uV 16:30:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.743 uVs 16:30:20 Integrated Voltage Measurement... 16:30:29 Voltage Offset Correction: v_off_ini = 3059.240 uV, v_off_fin = 3073.789 uV 16:30:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.790 uVs 16:30:33 I1X Average and RMS of Measurements VT = -109.746 +- 17.856 uVs I1X = 21.950 +- 3.571 uTm 16:30:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:30:40 Integrated Voltage Measurement... 16:30:49 Voltage Offset Correction: v_off_ini = 3081.191 uV, v_off_fin = 3073.664 uV 16:30:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.078 uVs 16:30:49 Integrated Voltage Measurement... 16:30:58 Voltage Offset Correction: v_off_ini = 3108.408 uV, v_off_fin = 3097.259 uV 16:30:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.204 uVs 16:30:58 Integrated Voltage Measurement... 16:31:07 Voltage Offset Correction: v_off_ini = 3104.123 uV, v_off_fin = 3083.056 uV 16:31:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.299 uVs 16:31:07 Integrated Voltage Measurement... 16:31:16 Voltage Offset Correction: v_off_ini = 3039.216 uV, v_off_fin = 3086.078 uV 16:31:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.402 uVs 16:31:16 Integrated Voltage Measurement... 16:31:25 Voltage Offset Correction: v_off_ini = 3088.991 uV, v_off_fin = 3099.223 uV 16:31:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.591 uVs 16:31:25 Integrated Voltage Measurement... 16:31:34 Voltage Offset Correction: v_off_ini = 3063.378 uV, v_off_fin = 3127.304 uV 16:31:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.022 uVs 16:31:38 I1Y Average and RMS of Measurements VT = -250.099 +- 13.854 uVs I1Y = -50.020 +- 2.771 uTm 16:31:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:31:46 Integrated Voltage Measurement... 16:31:55 Voltage Offset Correction: v_off_ini = 3103.279 uV, v_off_fin = 3076.797 uV 16:31:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -89.284 uVs 16:31:55 Integrated Voltage Measurement... 16:32:04 Voltage Offset Correction: v_off_ini = 3110.175 uV, v_off_fin = 3108.852 uV 16:32:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.236 uVs 16:32:04 Integrated Voltage Measurement... 16:32:13 Voltage Offset Correction: v_off_ini = 3093.442 uV, v_off_fin = 3061.972 uV 16:32:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.097 uVs 16:32:13 Integrated Voltage Measurement... 16:32:22 Voltage Offset Correction: v_off_ini = 3060.243 uV, v_off_fin = 3070.716 uV 16:32:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.109 uVs 16:32:22 Integrated Voltage Measurement... 16:32:31 Voltage Offset Correction: v_off_ini = 3060.198 uV, v_off_fin = 3057.188 uV 16:32:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.161 uVs 16:32:31 Integrated Voltage Measurement... 16:32:40 Voltage Offset Correction: v_off_ini = 3076.082 uV, v_off_fin = 3101.411 uV 16:32:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.036 uVs 16:32:43 I2X Average and RMS of Measurements VT = -122.820 +- 11.478 uVs I2X = 11.299 +- 1.056 uTm^2 16:32:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:32:50 Integrated Voltage Measurement... 16:32:59 Voltage Offset Correction: v_off_ini = 3050.261 uV, v_off_fin = 3054.718 uV 16:32:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -392.336 uVs 16:32:59 Integrated Voltage Measurement... 16:33:08 Voltage Offset Correction: v_off_ini = 3092.984 uV, v_off_fin = 3070.775 uV 16:33:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.784 uVs 16:33:08 Integrated Voltage Measurement... 16:33:17 Voltage Offset Correction: v_off_ini = 3091.835 uV, v_off_fin = 3078.535 uV 16:33:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -395.787 uVs 16:33:17 Integrated Voltage Measurement... 16:33:26 Voltage Offset Correction: v_off_ini = 3086.471 uV, v_off_fin = 3081.997 uV 16:33:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.885 uVs 16:33:26 Integrated Voltage Measurement... 16:33:35 Voltage Offset Correction: v_off_ini = 3097.914 uV, v_off_fin = 3087.996 uV 16:33:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -411.830 uVs 16:33:36 Integrated Voltage Measurement... 16:33:44 Voltage Offset Correction: v_off_ini = 3086.372 uV, v_off_fin = 3057.816 uV 16:33:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.312 uVs 16:33:47 I2Y Average and RMS of Measurements VT = -379.489 +- 8.757 uVs I2Y = -34.913 +- 0.806 uTm^2 16:33:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:33:59 Integrated Voltage Measurement... 16:34:08 Voltage Offset Correction: v_off_ini = 3055.514 uV, v_off_fin = 3026.517 uV 16:34:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.663 uVs 16:34:08 Integrated Voltage Measurement... 16:34:17 Voltage Offset Correction: v_off_ini = 3047.945 uV, v_off_fin = 3043.271 uV 16:34:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.473 uVs 16:34:17 Integrated Voltage Measurement... 16:34:26 Voltage Offset Correction: v_off_ini = 3048.797 uV, v_off_fin = 3034.643 uV 16:34:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.624 uVs 16:34:26 Integrated Voltage Measurement... 16:34:35 Voltage Offset Correction: v_off_ini = 3042.307 uV, v_off_fin = 3047.268 uV 16:34:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.486 uVs 16:34:35 Integrated Voltage Measurement... 16:34:44 Voltage Offset Correction: v_off_ini = 3032.922 uV, v_off_fin = 3032.221 uV 16:34:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.434 uVs 16:34:44 Integrated Voltage Measurement... 16:34:53 Voltage Offset Correction: v_off_ini = 3046.817 uV, v_off_fin = 3081.217 uV 16:34:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.845 uVs 16:34:57 I1X Average and RMS of Measurements VT = -123.754 +- 15.917 uVs I1X = 24.751 +- 3.183 uTm 16:35:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:35:04 Integrated Voltage Measurement... 16:35:13 Voltage Offset Correction: v_off_ini = 3052.596 uV, v_off_fin = 3052.321 uV 16:35:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.818 uVs 16:35:13 Integrated Voltage Measurement... 16:35:22 Voltage Offset Correction: v_off_ini = 3033.466 uV, v_off_fin = 3071.413 uV 16:35:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.650 uVs 16:35:22 Integrated Voltage Measurement... 16:35:31 Voltage Offset Correction: v_off_ini = 3045.027 uV, v_off_fin = 3043.944 uV 16:35:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.604 uVs 16:35:31 Integrated Voltage Measurement... 16:35:40 Voltage Offset Correction: v_off_ini = 3067.834 uV, v_off_fin = 3073.842 uV 16:35:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.332 uVs 16:35:40 Integrated Voltage Measurement... 16:35:49 Voltage Offset Correction: v_off_ini = 3043.277 uV, v_off_fin = 3046.654 uV 16:35:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.062 uVs 16:35:49 Integrated Voltage Measurement... 16:35:58 Voltage Offset Correction: v_off_ini = 3084.398 uV, v_off_fin = 3100.891 uV 16:35:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.152 uVs 16:36:02 I1Y Average and RMS of Measurements VT = -212.936 +- 8.449 uVs I1Y = -42.587 +- 1.690 uTm 16:36:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:36:07 Integrated Voltage Measurement... 16:36:16 Voltage Offset Correction: v_off_ini = 3095.460 uV, v_off_fin = 3055.728 uV 16:36:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.491 uVs 16:36:16 Integrated Voltage Measurement... 16:36:25 Voltage Offset Correction: v_off_ini = 3048.577 uV, v_off_fin = 3072.083 uV 16:36:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.684 uVs 16:36:25 Integrated Voltage Measurement... 16:36:34 Voltage Offset Correction: v_off_ini = 3067.649 uV, v_off_fin = 3073.208 uV 16:36:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.692 uVs 16:36:34 Integrated Voltage Measurement... 16:36:43 Voltage Offset Correction: v_off_ini = 3086.410 uV, v_off_fin = 3064.177 uV 16:36:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.793 uVs 16:36:43 Integrated Voltage Measurement... 16:36:52 Voltage Offset Correction: v_off_ini = 3062.847 uV, v_off_fin = 3020.564 uV 16:36:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.905 uVs 16:36:52 Integrated Voltage Measurement... 16:37:01 Voltage Offset Correction: v_off_ini = 3051.653 uV, v_off_fin = 3056.140 uV 16:37:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.010 uVs 16:37:04 I2X Average and RMS of Measurements VT = -119.763 +- 1.957 uVs I2X = 11.018 +- 0.180 uTm^2 16:37:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:37:09 Integrated Voltage Measurement... 16:37:18 Voltage Offset Correction: v_off_ini = 3044.216 uV, v_off_fin = 3034.749 uV 16:37:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.753 uVs 16:37:18 Integrated Voltage Measurement... 16:37:27 Voltage Offset Correction: v_off_ini = 3018.629 uV, v_off_fin = 3027.015 uV 16:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.991 uVs 16:37:27 Integrated Voltage Measurement... 16:37:36 Voltage Offset Correction: v_off_ini = 3034.778 uV, v_off_fin = 3044.553 uV 16:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.101 uVs 16:37:36 Integrated Voltage Measurement... 16:37:45 Voltage Offset Correction: v_off_ini = 3036.767 uV, v_off_fin = 3027.471 uV 16:37:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.021 uVs 16:37:45 Integrated Voltage Measurement... 16:37:54 Voltage Offset Correction: v_off_ini = 3056.588 uV, v_off_fin = 3027.264 uV 16:37:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.103 uVs 16:37:54 Integrated Voltage Measurement... 16:38:03 Voltage Offset Correction: v_off_ini = 3022.639 uV, v_off_fin = 3016.982 uV 16:38:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.242 uVs 16:38:05 I2Y Average and RMS of Measurements VT = -345.868 +- 8.587 uVs I2Y = -31.820 +- 0.790 uTm^2 16:38:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:38:14 Integrated Voltage Measurement... 16:38:23 Voltage Offset Correction: v_off_ini = 3024.766 uV, v_off_fin = 2995.759 uV 16:38:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.875 uVs 16:38:23 Integrated Voltage Measurement... 16:38:32 Voltage Offset Correction: v_off_ini = 3027.191 uV, v_off_fin = 3035.993 uV 16:38:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.334 uVs 16:38:32 Integrated Voltage Measurement... 16:38:41 Voltage Offset Correction: v_off_ini = 3074.817 uV, v_off_fin = 3062.052 uV 16:38:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.121 uVs 16:38:41 Integrated Voltage Measurement... 16:38:50 Voltage Offset Correction: v_off_ini = 3056.310 uV, v_off_fin = 3045.650 uV 16:38:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.634 uVs 16:38:50 Integrated Voltage Measurement... 16:38:59 Voltage Offset Correction: v_off_ini = 3049.460 uV, v_off_fin = 3038.744 uV 16:38:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.083 uVs 16:38:59 Integrated Voltage Measurement... 16:39:08 Voltage Offset Correction: v_off_ini = 3043.928 uV, v_off_fin = 3033.482 uV 16:39:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.771 uVs 16:39:12 I1X Average and RMS of Measurements VT = -125.970 +- 6.683 uVs I1X = 25.194 +- 1.336 uTm 16:39:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:39:19 Integrated Voltage Measurement... 16:39:28 Voltage Offset Correction: v_off_ini = 3042.667 uV, v_off_fin = 3030.228 uV 16:39:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.429 uVs 16:39:28 Integrated Voltage Measurement... 16:39:37 Voltage Offset Correction: v_off_ini = 3038.115 uV, v_off_fin = 3076.986 uV 16:39:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.836 uVs 16:39:37 Integrated Voltage Measurement... 16:39:46 Voltage Offset Correction: v_off_ini = 3064.665 uV, v_off_fin = 3047.824 uV 16:39:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.255 uVs 16:39:46 Integrated Voltage Measurement... 16:39:55 Voltage Offset Correction: v_off_ini = 3038.974 uV, v_off_fin = 3036.111 uV 16:39:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.651 uVs 16:39:55 Integrated Voltage Measurement... 16:40:04 Voltage Offset Correction: v_off_ini = 3007.776 uV, v_off_fin = 3004.608 uV 16:40:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.849 uVs 16:40:04 Integrated Voltage Measurement... 16:40:13 Voltage Offset Correction: v_off_ini = 3032.553 uV, v_off_fin = 3064.267 uV 16:40:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.151 uVs 16:40:17 I1Y Average and RMS of Measurements VT = -228.362 +- 3.608 uVs I1Y = -45.672 +- 0.722 uTm 16:40:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:40:22 Integrated Voltage Measurement... 16:40:31 Voltage Offset Correction: v_off_ini = 3067.427 uV, v_off_fin = 3048.285 uV 16:40:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.876 uVs 16:40:31 Integrated Voltage Measurement... 16:40:40 Voltage Offset Correction: v_off_ini = 3007.274 uV, v_off_fin = 3033.791 uV 16:40:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 160.591 uVs 16:40:40 Integrated Voltage Measurement... 16:40:49 Voltage Offset Correction: v_off_ini = 3053.996 uV, v_off_fin = 3039.552 uV 16:40:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.316 uVs 16:40:49 Integrated Voltage Measurement... 16:40:58 Voltage Offset Correction: v_off_ini = 3059.751 uV, v_off_fin = 3056.135 uV 16:40:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.205 uVs 16:40:58 Integrated Voltage Measurement... 16:41:07 Voltage Offset Correction: v_off_ini = 3066.080 uV, v_off_fin = 3039.526 uV 16:41:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.315 uVs 16:41:07 Integrated Voltage Measurement... 16:41:16 Voltage Offset Correction: v_off_ini = 3071.755 uV, v_off_fin = 3106.975 uV 16:41:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.701 uVs 16:41:18 I2X Average and RMS of Measurements VT = -132.001 +- 11.555 uVs I2X = 12.144 +- 1.063 uTm^2 16:41:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:41:24 Integrated Voltage Measurement... 16:41:33 Voltage Offset Correction: v_off_ini = 3043.260 uV, v_off_fin = 3057.788 uV 16:41:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.913 uVs 16:41:33 Integrated Voltage Measurement... 16:41:42 Voltage Offset Correction: v_off_ini = 3048.329 uV, v_off_fin = 3073.176 uV 16:41:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.520 uVs 16:41:42 Integrated Voltage Measurement... 16:41:51 Voltage Offset Correction: v_off_ini = 3024.062 uV, v_off_fin = 3049.411 uV 16:41:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.326 uVs 16:41:51 Integrated Voltage Measurement... 16:42:00 Voltage Offset Correction: v_off_ini = 3037.724 uV, v_off_fin = 3057.507 uV 16:42:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.791 uVs 16:42:00 Integrated Voltage Measurement... 16:42:09 Voltage Offset Correction: v_off_ini = 3081.276 uV, v_off_fin = 3065.668 uV 16:42:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.749 uVs 16:42:09 Integrated Voltage Measurement... 16:42:18 Voltage Offset Correction: v_off_ini = 3047.071 uV, v_off_fin = 3050.301 uV 16:42:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.076 uVs 16:42:20 I2Y Average and RMS of Measurements VT = -350.062 +- 10.867 uVs I2Y = -32.206 +- 1.000 uTm^2 16:42:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:28 Integrated Voltage Measurement... 16:42:37 Voltage Offset Correction: v_off_ini = 3038.306 uV, v_off_fin = 3033.544 uV 16:42:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -117.041 uVs 16:42:37 Integrated Voltage Measurement... 16:42:46 Voltage Offset Correction: v_off_ini = 3059.006 uV, v_off_fin = 3051.691 uV 16:42:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.551 uVs 16:42:46 Integrated Voltage Measurement... 16:42:55 Voltage Offset Correction: v_off_ini = 3049.899 uV, v_off_fin = 3035.450 uV 16:42:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.358 uVs 16:42:55 Integrated Voltage Measurement... 16:43:04 Voltage Offset Correction: v_off_ini = 3023.571 uV, v_off_fin = 3055.474 uV 16:43:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.252 uVs 16:43:04 Integrated Voltage Measurement... 16:43:13 Voltage Offset Correction: v_off_ini = 3043.437 uV, v_off_fin = 3030.530 uV 16:43:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.560 uVs 16:43:13 Integrated Voltage Measurement... 16:43:22 Voltage Offset Correction: v_off_ini = 3072.172 uV, v_off_fin = 3069.808 uV 16:43:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.713 uVs 16:43:27 I1X Average and RMS of Measurements VT = -111.413 +- 6.040 uVs I1X = 22.283 +- 1.209 uTm 16:43:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:43:33 Integrated Voltage Measurement... 16:43:42 Voltage Offset Correction: v_off_ini = 3051.819 uV, v_off_fin = 3033.265 uV 16:43:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.475 uVs 16:43:42 Integrated Voltage Measurement... 16:43:51 Voltage Offset Correction: v_off_ini = 3052.719 uV, v_off_fin = 3070.440 uV 16:43:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.440 uVs 16:43:51 Integrated Voltage Measurement... 16:44:00 Voltage Offset Correction: v_off_ini = 3084.312 uV, v_off_fin = 3035.700 uV 16:44:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.727 uVs 16:44:00 Integrated Voltage Measurement... 16:44:09 Voltage Offset Correction: v_off_ini = 3033.008 uV, v_off_fin = 3057.881 uV 16:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.171 uVs 16:44:09 Integrated Voltage Measurement... 16:44:18 Voltage Offset Correction: v_off_ini = 3036.267 uV, v_off_fin = 3053.510 uV 16:44:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.461 uVs 16:44:18 Integrated Voltage Measurement... 16:44:27 Voltage Offset Correction: v_off_ini = 3024.045 uV, v_off_fin = 3059.900 uV 16:44:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.962 uVs 16:44:32 I1Y Average and RMS of Measurements VT = -224.873 +- 2.977 uVs I1Y = -44.973 +- 0.596 uTm 16:44:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:44:37 Integrated Voltage Measurement... 16:44:46 Voltage Offset Correction: v_off_ini = 3024.420 uV, v_off_fin = 3015.223 uV 16:44:46 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -132.732 uVs 16:44:46 Integrated Voltage Measurement... 16:44:55 Voltage Offset Correction: v_off_ini = 3018.720 uV, v_off_fin = 3025.616 uV 16:44:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.718 uVs 16:44:55 Integrated Voltage Measurement... 16:45:04 Voltage Offset Correction: v_off_ini = 3006.317 uV, v_off_fin = 3038.840 uV 16:45:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.482 uVs 16:45:04 Integrated Voltage Measurement... 16:45:13 Voltage Offset Correction: v_off_ini = 3022.400 uV, v_off_fin = 3034.959 uV 16:45:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.269 uVs 16:45:13 Integrated Voltage Measurement... 16:45:22 Voltage Offset Correction: v_off_ini = 2997.693 uV, v_off_fin = 3021.146 uV 16:45:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.491 uVs 16:45:22 Integrated Voltage Measurement... 16:45:31 Voltage Offset Correction: v_off_ini = 3040.135 uV, v_off_fin = 2997.028 uV 16:45:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 166.047 uVs 16:45:33 I2X Average and RMS of Measurements VT = -130.790 +- 5.290 uVs I2X = 12.032 +- 0.487 uTm^2 16:45:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:45:38 Integrated Voltage Measurement... 16:45:47 Voltage Offset Correction: v_off_ini = 3035.193 uV, v_off_fin = 3004.536 uV 16:45:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.685 uVs 16:45:47 Integrated Voltage Measurement... 16:45:56 Voltage Offset Correction: v_off_ini = 3016.807 uV, v_off_fin = 3026.812 uV 16:45:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.004 uVs 16:45:56 Integrated Voltage Measurement... 16:46:05 Voltage Offset Correction: v_off_ini = 3016.656 uV, v_off_fin = 2977.358 uV 16:46:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.026 uVs 16:46:05 Integrated Voltage Measurement... 16:46:14 Voltage Offset Correction: v_off_ini = 2976.747 uV, v_off_fin = 3011.113 uV 16:46:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.662 uVs 16:46:14 Integrated Voltage Measurement... 16:46:23 Voltage Offset Correction: v_off_ini = 3050.538 uV, v_off_fin = 2987.147 uV 16:46:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.407 uVs 16:46:23 Integrated Voltage Measurement... 16:46:32 Voltage Offset Correction: v_off_ini = 3014.163 uV, v_off_fin = 2986.254 uV 16:46:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.751 uVs 16:46:35 I2Y Average and RMS of Measurements VT = -353.256 +- 11.943 uVs I2Y = -32.500 +- 1.099 uTm^2 16:46:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:46:43 Integrated Voltage Measurement... 16:46:52 Voltage Offset Correction: v_off_ini = 3004.141 uV, v_off_fin = 3016.394 uV 16:46:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.143 uVs 16:46:52 Integrated Voltage Measurement... 16:47:01 Voltage Offset Correction: v_off_ini = 3009.159 uV, v_off_fin = 3010.288 uV 16:47:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.483 uVs 16:47:01 Integrated Voltage Measurement... 16:47:10 Voltage Offset Correction: v_off_ini = 2987.895 uV, v_off_fin = 2991.698 uV 16:47:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.638 uVs 16:47:10 Integrated Voltage Measurement... 16:47:19 Voltage Offset Correction: v_off_ini = 2977.389 uV, v_off_fin = 2971.232 uV 16:47:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.585 uVs 16:47:19 Integrated Voltage Measurement... 16:47:28 Voltage Offset Correction: v_off_ini = 2976.980 uV, v_off_fin = 2994.785 uV 16:47:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.720 uVs 16:47:28 Integrated Voltage Measurement... 16:47:37 Voltage Offset Correction: v_off_ini = 3000.936 uV, v_off_fin = 3004.601 uV 16:47:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.294 uVs 16:47:41 I1X Average and RMS of Measurements VT = -106.477 +- 12.114 uVs I1X = 21.296 +- 2.423 uTm 16:47:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:47:48 Integrated Voltage Measurement... 16:47:57 Voltage Offset Correction: v_off_ini = 2946.375 uV, v_off_fin = 2962.272 uV 16:47:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.817 uVs 16:47:57 Integrated Voltage Measurement... 16:48:06 Voltage Offset Correction: v_off_ini = 2986.979 uV, v_off_fin = 2983.497 uV 16:48:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 248.053 uVs 16:48:06 Integrated Voltage Measurement... 16:48:15 Voltage Offset Correction: v_off_ini = 2960.283 uV, v_off_fin = 2959.603 uV 16:48:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.330 uVs 16:48:15 Integrated Voltage Measurement... 16:48:24 Voltage Offset Correction: v_off_ini = 2986.603 uV, v_off_fin = 2973.767 uV 16:48:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.830 uVs 16:48:24 Integrated Voltage Measurement... 16:48:33 Voltage Offset Correction: v_off_ini = 2927.598 uV, v_off_fin = 2950.884 uV 16:48:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.351 uVs 16:48:33 Integrated Voltage Measurement... 16:48:42 Voltage Offset Correction: v_off_ini = 2932.111 uV, v_off_fin = 2998.723 uV 16:48:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.392 uVs 16:48:46 I1Y Average and RMS of Measurements VT = -212.795 +- 3.791 uVs I1Y = -42.556 +- 0.760 uTm 16:48:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:48:51 Integrated Voltage Measurement... 16:49:00 Voltage Offset Correction: v_off_ini = 2938.554 uV, v_off_fin = 2959.100 uV 16:49:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.877 uVs 16:49:00 Integrated Voltage Measurement... 16:49:09 Voltage Offset Correction: v_off_ini = 2935.298 uV, v_off_fin = 2953.877 uV 16:49:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.150 uVs 16:49:10 Integrated Voltage Measurement... 16:49:19 Voltage Offset Correction: v_off_ini = 2975.273 uV, v_off_fin = 2968.557 uV 16:49:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.568 uVs 16:49:19 Integrated Voltage Measurement... 16:49:28 Voltage Offset Correction: v_off_ini = 2971.958 uV, v_off_fin = 2981.020 uV 16:49:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.576 uVs 16:49:28 Integrated Voltage Measurement... 16:49:37 Voltage Offset Correction: v_off_ini = 2944.898 uV, v_off_fin = 2919.081 uV 16:49:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.337 uVs 16:49:37 Integrated Voltage Measurement... 16:49:46 Voltage Offset Correction: v_off_ini = 2918.391 uV, v_off_fin = 2917.755 uV 16:49:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.618 uVs 16:49:48 I2X Average and RMS of Measurements VT = -129.854 +- 6.795 uVs I2X = 11.947 +- 0.625 uTm^2 16:49:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:49:53 Integrated Voltage Measurement... 16:50:02 Voltage Offset Correction: v_off_ini = 2964.589 uV, v_off_fin = 2944.770 uV 16:50:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.036 uVs 16:50:02 Integrated Voltage Measurement... 16:50:11 Voltage Offset Correction: v_off_ini = 2905.143 uV, v_off_fin = 2885.559 uV 16:50:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.331 uVs 16:50:11 Integrated Voltage Measurement... 16:50:20 Voltage Offset Correction: v_off_ini = 2950.878 uV, v_off_fin = 2930.668 uV 16:50:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -338.572 uVs 16:50:20 Integrated Voltage Measurement... 16:50:29 Voltage Offset Correction: v_off_ini = 2921.919 uV, v_off_fin = 2946.278 uV 16:50:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 386.696 uVs 16:50:29 Integrated Voltage Measurement... 16:50:38 Voltage Offset Correction: v_off_ini = 2962.846 uV, v_off_fin = 2943.782 uV 16:50:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.882 uVs 16:50:38 Integrated Voltage Measurement... 16:50:47 Voltage Offset Correction: v_off_ini = 2942.580 uV, v_off_fin = 2923.291 uV 16:50:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.681 uVs 16:50:50 I2Y Average and RMS of Measurements VT = -344.700 +- 13.335 uVs I2Y = -31.712 +- 1.227 uTm^2 16:50:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:50:58 Integrated Voltage Measurement... 16:51:07 Voltage Offset Correction: v_off_ini = 2946.058 uV, v_off_fin = 2963.487 uV 16:51:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.714 uVs 16:51:07 Integrated Voltage Measurement... 16:51:16 Voltage Offset Correction: v_off_ini = 2963.839 uV, v_off_fin = 2969.990 uV 16:51:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.274 uVs 16:51:16 Integrated Voltage Measurement... 16:51:25 Voltage Offset Correction: v_off_ini = 2962.816 uV, v_off_fin = 2960.468 uV 16:51:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.588 uVs 16:51:25 Integrated Voltage Measurement... 16:51:34 Voltage Offset Correction: v_off_ini = 2936.463 uV, v_off_fin = 2896.371 uV 16:51:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.631 uVs 16:51:34 Integrated Voltage Measurement... 16:51:43 Voltage Offset Correction: v_off_ini = 2911.840 uV, v_off_fin = 2927.333 uV 16:51:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.101 uVs 16:51:43 Integrated Voltage Measurement... 16:51:52 Voltage Offset Correction: v_off_ini = 2909.287 uV, v_off_fin = 2906.451 uV 16:51:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.560 uVs 16:51:56 I1X Average and RMS of Measurements VT = -116.311 +- 15.417 uVs I1X = 23.262 +- 3.083 uTm 16:51:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:52:03 Integrated Voltage Measurement... 16:52:12 Voltage Offset Correction: v_off_ini = 2914.306 uV, v_off_fin = 2908.911 uV 16:52:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -249.295 uVs 16:52:12 Integrated Voltage Measurement... 16:52:21 Voltage Offset Correction: v_off_ini = 2936.779 uV, v_off_fin = 2939.784 uV 16:52:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.088 uVs 16:52:21 Integrated Voltage Measurement... 16:52:30 Voltage Offset Correction: v_off_ini = 2955.543 uV, v_off_fin = 2927.496 uV 16:52:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.241 uVs 16:52:30 Integrated Voltage Measurement... 16:52:39 Voltage Offset Correction: v_off_ini = 2930.706 uV, v_off_fin = 2915.605 uV 16:52:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.484 uVs 16:52:39 Integrated Voltage Measurement... 16:52:48 Voltage Offset Correction: v_off_ini = 2919.078 uV, v_off_fin = 2957.529 uV 16:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.534 uVs 16:52:48 Integrated Voltage Measurement... 16:52:57 Voltage Offset Correction: v_off_ini = 2936.462 uV, v_off_fin = 2937.769 uV 16:52:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.855 uVs 16:53:01 I1Y Average and RMS of Measurements VT = -226.416 +- 9.962 uVs I1Y = -45.279 +- 1.991 uTm 16:53:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:53:06 Integrated Voltage Measurement... 16:53:15 Voltage Offset Correction: v_off_ini = 2951.099 uV, v_off_fin = 2935.964 uV 16:53:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.280 uVs 16:53:15 Integrated Voltage Measurement... 16:53:24 Voltage Offset Correction: v_off_ini = 2958.355 uV, v_off_fin = 2965.443 uV 16:53:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.175 uVs 16:53:24 Integrated Voltage Measurement... 16:53:33 Voltage Offset Correction: v_off_ini = 2991.852 uV, v_off_fin = 2954.268 uV 16:53:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.214 uVs 16:53:33 Integrated Voltage Measurement... 16:53:42 Voltage Offset Correction: v_off_ini = 2944.013 uV, v_off_fin = 2966.116 uV 16:53:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.268 uVs 16:53:42 Integrated Voltage Measurement... 16:53:51 Voltage Offset Correction: v_off_ini = 2994.424 uV, v_off_fin = 2982.753 uV 16:53:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.997 uVs 16:53:51 Integrated Voltage Measurement... 16:54:00 Voltage Offset Correction: v_off_ini = 2976.976 uV, v_off_fin = 3002.441 uV 16:54:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.113 uVs 16:54:03 I2X Average and RMS of Measurements VT = -121.008 +- 4.587 uVs I2X = 11.133 +- 0.422 uTm^2 16:54:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:54:08 Integrated Voltage Measurement... 16:54:17 Voltage Offset Correction: v_off_ini = 3005.846 uV, v_off_fin = 3020.124 uV 16:54:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.017 uVs 16:54:17 Integrated Voltage Measurement... 16:54:26 Voltage Offset Correction: v_off_ini = 2993.137 uV, v_off_fin = 2970.325 uV 16:54:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 368.998 uVs 16:54:26 Integrated Voltage Measurement... 16:54:35 Voltage Offset Correction: v_off_ini = 2950.113 uV, v_off_fin = 2950.965 uV 16:54:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -343.728 uVs 16:54:35 Integrated Voltage Measurement... 16:54:44 Voltage Offset Correction: v_off_ini = 2975.409 uV, v_off_fin = 2981.619 uV 16:54:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.809 uVs 16:54:44 Integrated Voltage Measurement... 16:54:53 Voltage Offset Correction: v_off_ini = 2964.405 uV, v_off_fin = 2995.881 uV 16:54:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.564 uVs 16:54:53 Integrated Voltage Measurement... 16:55:02 Voltage Offset Correction: v_off_ini = 2970.473 uV, v_off_fin = 2951.241 uV 16:55:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.073 uVs 16:55:04 I2Y Average and RMS of Measurements VT = -354.532 +- 10.115 uVs I2Y = -32.617 +- 0.931 uTm^2 16:55:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:55:26 Integrated Voltage Measurement... 16:55:35 Voltage Offset Correction: v_off_ini = 2996.164 uV, v_off_fin = 2989.075 uV 16:55:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.402 uVs 16:55:35 Integrated Voltage Measurement... 16:55:44 Voltage Offset Correction: v_off_ini = 3007.286 uV, v_off_fin = 3002.301 uV 16:55:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 154.973 uVs 16:55:44 Integrated Voltage Measurement... 16:55:53 Voltage Offset Correction: v_off_ini = 3040.273 uV, v_off_fin = 3036.916 uV 16:55:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.396 uVs 16:55:53 Integrated Voltage Measurement... 16:56:02 Voltage Offset Correction: v_off_ini = 2996.306 uV, v_off_fin = 3020.526 uV 16:56:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.900 uVs 16:56:02 Integrated Voltage Measurement... 16:56:11 Voltage Offset Correction: v_off_ini = 3029.817 uV, v_off_fin = 3042.341 uV 16:56:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.600 uVs 16:56:11 Integrated Voltage Measurement... 16:56:20 Voltage Offset Correction: v_off_ini = 3049.850 uV, v_off_fin = 3071.020 uV 16:56:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.100 uVs 16:56:24 I1X Average and RMS of Measurements VT = -116.062 +- 5.787 uVs I1X = 23.214 +- 1.158 uTm 16:56:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:56:31 Integrated Voltage Measurement... 16:56:40 Voltage Offset Correction: v_off_ini = 3041.244 uV, v_off_fin = 3027.756 uV 16:56:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.193 uVs 16:56:40 Integrated Voltage Measurement... 16:56:49 Voltage Offset Correction: v_off_ini = 3000.659 uV, v_off_fin = 3029.899 uV 16:56:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.092 uVs 16:56:49 Integrated Voltage Measurement... 16:56:58 Voltage Offset Correction: v_off_ini = 3020.015 uV, v_off_fin = 3018.893 uV 16:56:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.796 uVs 16:56:58 Integrated Voltage Measurement... 16:57:07 Voltage Offset Correction: v_off_ini = 3000.351 uV, v_off_fin = 3014.471 uV 16:57:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.202 uVs 16:57:07 Integrated Voltage Measurement... 16:57:16 Voltage Offset Correction: v_off_ini = 2988.784 uV, v_off_fin = 2994.095 uV 16:57:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.289 uVs 16:57:16 Integrated Voltage Measurement... 16:57:25 Voltage Offset Correction: v_off_ini = 3041.266 uV, v_off_fin = 3059.441 uV 16:57:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.704 uVs 16:57:29 I1Y Average and RMS of Measurements VT = -191.546 +- 4.087 uVs I1Y = -38.309 +- 0.817 uTm 16:57:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:57:36 Integrated Voltage Measurement... 16:57:45 Voltage Offset Correction: v_off_ini = 2994.690 uV, v_off_fin = 3003.347 uV 16:57:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.707 uVs 16:57:45 Integrated Voltage Measurement... 16:57:54 Voltage Offset Correction: v_off_ini = 2995.623 uV, v_off_fin = 3032.734 uV 16:57:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 194.596 uVs 16:57:54 Integrated Voltage Measurement... 16:58:03 Voltage Offset Correction: v_off_ini = 3017.054 uV, v_off_fin = 3018.875 uV 16:58:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.236 uVs 16:58:04 Integrated Voltage Measurement... 16:58:12 Voltage Offset Correction: v_off_ini = 3028.593 uV, v_off_fin = 2997.873 uV 16:58:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.896 uVs 16:58:13 Integrated Voltage Measurement... 16:58:22 Voltage Offset Correction: v_off_ini = 2953.941 uV, v_off_fin = 2984.719 uV 16:58:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.597 uVs 16:58:22 Integrated Voltage Measurement... 16:58:31 Voltage Offset Correction: v_off_ini = 2989.922 uV, v_off_fin = 3017.578 uV 16:58:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.045 uVs 16:58:33 I2X Average and RMS of Measurements VT = -131.846 +- 29.788 uVs I2X = 12.130 +- 2.741 uTm^2 16:58:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:58:41 Integrated Voltage Measurement... 16:58:50 Voltage Offset Correction: v_off_ini = 2996.689 uV, v_off_fin = 3005.657 uV 16:58:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.785 uVs 16:58:50 Integrated Voltage Measurement... 16:58:59 Voltage Offset Correction: v_off_ini = 2974.025 uV, v_off_fin = 2993.266 uV 16:58:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.578 uVs 16:58:59 Integrated Voltage Measurement... 16:59:08 Voltage Offset Correction: v_off_ini = 3004.253 uV, v_off_fin = 2996.132 uV 16:59:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.707 uVs 16:59:08 Integrated Voltage Measurement... 16:59:17 Voltage Offset Correction: v_off_ini = 3010.651 uV, v_off_fin = 3007.788 uV 16:59:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.904 uVs 16:59:17 Integrated Voltage Measurement... 16:59:26 Voltage Offset Correction: v_off_ini = 3009.738 uV, v_off_fin = 3017.730 uV 16:59:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.487 uVs 16:59:26 Integrated Voltage Measurement... 16:59:35 Voltage Offset Correction: v_off_ini = 3038.497 uV, v_off_fin = 3040.055 uV 16:59:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.544 uVs 16:59:37 I2Y Average and RMS of Measurements VT = -318.001 +- 7.889 uVs I2Y = -29.256 +- 0.726 uTm^2 16:59:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:59:46 Integrated Voltage Measurement... 16:59:55 Voltage Offset Correction: v_off_ini = 3021.817 uV, v_off_fin = 3015.087 uV 16:59:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.117 uVs 16:59:55 Integrated Voltage Measurement... 17:00:04 Voltage Offset Correction: v_off_ini = 3007.795 uV, v_off_fin = 3015.129 uV 17:00:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.536 uVs 17:00:04 Integrated Voltage Measurement... 17:00:13 Voltage Offset Correction: v_off_ini = 3007.390 uV, v_off_fin = 3024.121 uV 17:00:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.677 uVs 17:00:13 Integrated Voltage Measurement... 17:00:22 Voltage Offset Correction: v_off_ini = 3033.407 uV, v_off_fin = 3010.485 uV 17:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.058 uVs 17:00:22 Integrated Voltage Measurement... 17:00:31 Voltage Offset Correction: v_off_ini = 3011.090 uV, v_off_fin = 3005.959 uV 17:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.466 uVs 17:00:31 Integrated Voltage Measurement... 17:00:40 Voltage Offset Correction: v_off_ini = 3038.289 uV, v_off_fin = 3035.978 uV 17:00:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.382 uVs 17:00:44 I1X Average and RMS of Measurements VT = -97.039 +- 7.883 uVs I1X = 19.408 +- 1.577 uTm 17:00:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:00:51 Integrated Voltage Measurement... 17:01:00 Voltage Offset Correction: v_off_ini = 3010.683 uV, v_off_fin = 3002.508 uV 17:01:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.534 uVs 17:01:00 Integrated Voltage Measurement... 17:01:09 Voltage Offset Correction: v_off_ini = 3032.156 uV, v_off_fin = 3024.635 uV 17:01:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.513 uVs 17:01:09 Integrated Voltage Measurement... 17:01:18 Voltage Offset Correction: v_off_ini = 3003.124 uV, v_off_fin = 3013.457 uV 17:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.671 uVs 17:01:18 Integrated Voltage Measurement... 17:01:27 Voltage Offset Correction: v_off_ini = 2992.348 uV, v_off_fin = 3027.800 uV 17:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.675 uVs 17:01:27 Integrated Voltage Measurement... 17:01:36 Voltage Offset Correction: v_off_ini = 3039.554 uV, v_off_fin = 3043.702 uV 17:01:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.758 uVs 17:01:36 Integrated Voltage Measurement... 17:01:45 Voltage Offset Correction: v_off_ini = 3061.846 uV, v_off_fin = 3036.494 uV 17:01:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.550 uVs 17:01:49 I1Y Average and RMS of Measurements VT = -192.450 +- 15.503 uVs I1Y = -38.490 +- 3.101 uTm 17:01:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:01:57 Integrated Voltage Measurement... 17:02:06 Voltage Offset Correction: v_off_ini = 3052.467 uV, v_off_fin = 3055.291 uV 17:02:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.199 uVs 17:02:06 Integrated Voltage Measurement... 17:02:15 Voltage Offset Correction: v_off_ini = 3080.328 uV, v_off_fin = 3039.108 uV 17:02:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 176.054 uVs 17:02:15 Integrated Voltage Measurement... 17:02:24 Voltage Offset Correction: v_off_ini = 3045.890 uV, v_off_fin = 3065.038 uV 17:02:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -124.457 uVs 17:02:24 Integrated Voltage Measurement... 17:02:33 Voltage Offset Correction: v_off_ini = 3056.952 uV, v_off_fin = 3046.273 uV 17:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.430 uVs 17:02:33 Integrated Voltage Measurement... 17:02:42 Voltage Offset Correction: v_off_ini = 3050.591 uV, v_off_fin = 3061.745 uV 17:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.516 uVs 17:02:42 Integrated Voltage Measurement... 17:02:51 Voltage Offset Correction: v_off_ini = 3068.207 uV, v_off_fin = 3010.474 uV 17:02:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 164.303 uVs 17:02:54 I2X Average and RMS of Measurements VT = -134.993 +- 10.801 uVs I2X = 12.420 +- 0.994 uTm^2 17:02:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:03:01 Integrated Voltage Measurement... 17:03:10 Voltage Offset Correction: v_off_ini = 3082.330 uV, v_off_fin = 3070.243 uV 17:03:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.757 uVs 17:03:10 Integrated Voltage Measurement... 17:03:19 Voltage Offset Correction: v_off_ini = 3015.822 uV, v_off_fin = 3042.507 uV 17:03:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 402.289 uVs 17:03:19 Integrated Voltage Measurement... 17:03:28 Voltage Offset Correction: v_off_ini = 3027.458 uV, v_off_fin = 3023.872 uV 17:03:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.234 uVs 17:03:28 Integrated Voltage Measurement... 17:03:37 Voltage Offset Correction: v_off_ini = 3011.882 uV, v_off_fin = 3031.903 uV 17:03:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.945 uVs 17:03:37 Integrated Voltage Measurement... 17:03:46 Voltage Offset Correction: v_off_ini = 3032.113 uV, v_off_fin = 3032.786 uV 17:03:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.918 uVs 17:03:46 Integrated Voltage Measurement... 17:03:55 Voltage Offset Correction: v_off_ini = 2995.387 uV, v_off_fin = 3028.470 uV 17:03:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.427 uVs 17:03:58 I2Y Average and RMS of Measurements VT = -341.595 +- 15.234 uVs I2Y = -31.427 +- 1.402 uTm^2 17:04:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:04:07 Integrated Voltage Measurement... 17:04:16 Voltage Offset Correction: v_off_ini = 3033.113 uV, v_off_fin = 3005.063 uV 17:04:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.582 uVs 17:04:16 Integrated Voltage Measurement... 17:04:25 Voltage Offset Correction: v_off_ini = 2992.566 uV, v_off_fin = 2979.909 uV 17:04:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.178 uVs 17:04:25 Integrated Voltage Measurement... 17:04:34 Voltage Offset Correction: v_off_ini = 3007.161 uV, v_off_fin = 3011.196 uV 17:04:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.948 uVs 17:04:34 Integrated Voltage Measurement... 17:04:43 Voltage Offset Correction: v_off_ini = 3059.777 uV, v_off_fin = 3049.728 uV 17:04:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.145 uVs 17:04:43 Integrated Voltage Measurement... 17:04:52 Voltage Offset Correction: v_off_ini = 3087.123 uV, v_off_fin = 3067.333 uV 17:04:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.860 uVs 17:04:52 Integrated Voltage Measurement... 17:05:01 Voltage Offset Correction: v_off_ini = 3054.241 uV, v_off_fin = 3066.870 uV 17:05:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.695 uVs 17:05:05 I1X Average and RMS of Measurements VT = -102.735 +- 6.627 uVs I1X = 20.547 +- 1.326 uTm 17:05:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:05:12 Integrated Voltage Measurement... 17:05:21 Voltage Offset Correction: v_off_ini = 3113.226 uV, v_off_fin = 3045.552 uV 17:05:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.426 uVs 17:05:21 Integrated Voltage Measurement... 17:05:30 Voltage Offset Correction: v_off_ini = 3045.716 uV, v_off_fin = 3057.829 uV 17:05:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.884 uVs 17:05:30 Integrated Voltage Measurement... 17:05:39 Voltage Offset Correction: v_off_ini = 3042.814 uV, v_off_fin = 3028.823 uV 17:05:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.799 uVs 17:05:39 Integrated Voltage Measurement... 17:05:48 Voltage Offset Correction: v_off_ini = 3031.719 uV, v_off_fin = 3050.031 uV 17:05:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.920 uVs 17:05:48 Integrated Voltage Measurement... 17:05:57 Voltage Offset Correction: v_off_ini = 3034.372 uV, v_off_fin = 3068.154 uV 17:05:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.457 uVs 17:05:57 Integrated Voltage Measurement... 17:06:06 Voltage Offset Correction: v_off_ini = 3081.220 uV, v_off_fin = 3077.722 uV 17:06:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.841 uVs 17:06:10 I1Y Average and RMS of Measurements VT = -224.888 +- 12.024 uVs I1Y = -44.978 +- 2.405 uTm 17:06:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:06:18 Integrated Voltage Measurement... 17:06:27 Voltage Offset Correction: v_off_ini = 3043.932 uV, v_off_fin = 3053.198 uV 17:06:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.484 uVs 17:06:27 Integrated Voltage Measurement... 17:06:36 Voltage Offset Correction: v_off_ini = 3075.906 uV, v_off_fin = 3079.530 uV 17:06:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.582 uVs 17:06:36 Integrated Voltage Measurement... 17:06:45 Voltage Offset Correction: v_off_ini = 3054.189 uV, v_off_fin = 3029.100 uV 17:06:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.730 uVs 17:06:45 Integrated Voltage Measurement... 17:06:54 Voltage Offset Correction: v_off_ini = 3061.429 uV, v_off_fin = 3049.646 uV 17:06:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.765 uVs 17:06:54 Integrated Voltage Measurement... 17:07:03 Voltage Offset Correction: v_off_ini = 3043.170 uV, v_off_fin = 3033.550 uV 17:07:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.383 uVs 17:07:03 Integrated Voltage Measurement... 17:07:12 Voltage Offset Correction: v_off_ini = 3042.581 uV, v_off_fin = 3051.084 uV 17:07:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.769 uVs 17:07:14 I2X Average and RMS of Measurements VT = -100.619 +- 8.395 uVs I2X = 9.257 +- 0.772 uTm^2 17:07:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:07:22 Integrated Voltage Measurement... 17:07:31 Voltage Offset Correction: v_off_ini = 3064.591 uV, v_off_fin = 3066.590 uV 17:07:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.363 uVs 17:07:31 Integrated Voltage Measurement... 17:07:40 Voltage Offset Correction: v_off_ini = 3046.447 uV, v_off_fin = 3106.619 uV 17:07:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.342 uVs 17:07:40 Integrated Voltage Measurement... 17:07:49 Voltage Offset Correction: v_off_ini = 3071.922 uV, v_off_fin = 3085.046 uV 17:07:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -374.314 uVs 17:07:49 Integrated Voltage Measurement... 17:07:58 Voltage Offset Correction: v_off_ini = 3052.765 uV, v_off_fin = 3069.818 uV 17:07:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 392.658 uVs 17:07:58 Integrated Voltage Measurement... 17:08:07 Voltage Offset Correction: v_off_ini = 3053.344 uV, v_off_fin = 3054.586 uV 17:08:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.379 uVs 17:08:07 Integrated Voltage Measurement... 17:08:16 Voltage Offset Correction: v_off_ini = 3082.656 uV, v_off_fin = 3095.100 uV 17:08:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.761 uVs 17:08:18 I2Y Average and RMS of Measurements VT = -353.303 +- 22.535 uVs I2Y = -32.504 +- 2.073 uTm^2 17:08:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:08:27 Integrated Voltage Measurement... 17:08:36 Voltage Offset Correction: v_off_ini = 3059.904 uV, v_off_fin = 3036.425 uV 17:08:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.651 uVs 17:08:36 Integrated Voltage Measurement... 17:08:45 Voltage Offset Correction: v_off_ini = 3033.603 uV, v_off_fin = 3049.943 uV 17:08:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.547 uVs 17:08:45 Integrated Voltage Measurement... 17:08:54 Voltage Offset Correction: v_off_ini = 3025.234 uV, v_off_fin = 3018.938 uV 17:08:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.361 uVs 17:08:54 Integrated Voltage Measurement... 17:09:03 Voltage Offset Correction: v_off_ini = 3044.872 uV, v_off_fin = 3043.469 uV 17:09:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.925 uVs 17:09:03 Integrated Voltage Measurement... 17:09:12 Voltage Offset Correction: v_off_ini = 3061.377 uV, v_off_fin = 3063.262 uV 17:09:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.168 uVs 17:09:12 Integrated Voltage Measurement... 17:09:21 Voltage Offset Correction: v_off_ini = 3091.947 uV, v_off_fin = 3058.835 uV 17:09:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.939 uVs 17:09:26 I1X Average and RMS of Measurements VT = -112.265 +- 10.040 uVs I1X = 22.453 +- 2.008 uTm 17:09:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:09:32 Integrated Voltage Measurement... 17:09:41 Voltage Offset Correction: v_off_ini = 3046.618 uV, v_off_fin = 3035.176 uV 17:09:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -210.260 uVs 17:09:41 Integrated Voltage Measurement... 17:09:50 Voltage Offset Correction: v_off_ini = 3058.726 uV, v_off_fin = 3065.024 uV 17:09:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.360 uVs 17:09:50 Integrated Voltage Measurement... 17:09:59 Voltage Offset Correction: v_off_ini = 3059.599 uV, v_off_fin = 3027.337 uV 17:09:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.718 uVs 17:09:59 Integrated Voltage Measurement... 17:10:08 Voltage Offset Correction: v_off_ini = 3075.456 uV, v_off_fin = 3063.082 uV 17:10:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.918 uVs 17:10:08 Integrated Voltage Measurement... 17:10:17 Voltage Offset Correction: v_off_ini = 3081.325 uV, v_off_fin = 3030.461 uV 17:10:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.014 uVs 17:10:17 Integrated Voltage Measurement... 17:10:26 Voltage Offset Correction: v_off_ini = 3035.151 uV, v_off_fin = 3051.200 uV 17:10:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.475 uVs 17:10:31 I1Y Average and RMS of Measurements VT = -227.624 +- 9.056 uVs I1Y = -45.526 +- 1.811 uTm 17:10:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:10:38 Integrated Voltage Measurement... 17:10:47 Voltage Offset Correction: v_off_ini = 3047.678 uV, v_off_fin = 3065.038 uV 17:10:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.362 uVs 17:10:47 Integrated Voltage Measurement... 17:10:56 Voltage Offset Correction: v_off_ini = 3071.185 uV, v_off_fin = 3083.996 uV 17:10:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.619 uVs 17:10:56 Integrated Voltage Measurement... 17:11:05 Voltage Offset Correction: v_off_ini = 3086.304 uV, v_off_fin = 3080.766 uV 17:11:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.357 uVs 17:11:05 Integrated Voltage Measurement... 17:11:14 Voltage Offset Correction: v_off_ini = 3068.189 uV, v_off_fin = 3050.206 uV 17:11:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.561 uVs 17:11:14 Integrated Voltage Measurement... 17:11:23 Voltage Offset Correction: v_off_ini = 3062.400 uV, v_off_fin = 3053.534 uV 17:11:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.678 uVs 17:11:23 Integrated Voltage Measurement... 17:11:32 Voltage Offset Correction: v_off_ini = 3063.838 uV, v_off_fin = 3074.647 uV 17:11:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.034 uVs 17:11:35 I2X Average and RMS of Measurements VT = -120.602 +- 5.599 uVs I2X = 11.095 +- 0.515 uTm^2 17:11:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:11:43 Integrated Voltage Measurement... 17:11:51 Voltage Offset Correction: v_off_ini = 3096.644 uV, v_off_fin = 3115.167 uV 17:11:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -343.146 uVs 17:11:52 Integrated Voltage Measurement... 17:12:01 Voltage Offset Correction: v_off_ini = 3101.616 uV, v_off_fin = 3065.733 uV 17:12:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.319 uVs 17:12:01 Integrated Voltage Measurement... 17:12:10 Voltage Offset Correction: v_off_ini = 3094.724 uV, v_off_fin = 3069.490 uV 17:12:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.097 uVs 17:12:10 Integrated Voltage Measurement... 17:12:19 Voltage Offset Correction: v_off_ini = 3077.810 uV, v_off_fin = 3069.133 uV 17:12:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.166 uVs 17:12:19 Integrated Voltage Measurement... 17:12:28 Voltage Offset Correction: v_off_ini = 3102.435 uV, v_off_fin = 3125.984 uV 17:12:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.494 uVs 17:12:28 Integrated Voltage Measurement... 17:12:37 Voltage Offset Correction: v_off_ini = 3086.450 uV, v_off_fin = 3079.548 uV 17:12:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.203 uVs 17:12:39 I2Y Average and RMS of Measurements VT = -334.904 +- 4.785 uVs I2Y = -30.811 +- 0.440 uTm^2 17:12:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:12:48 Integrated Voltage Measurement... 17:12:57 Voltage Offset Correction: v_off_ini = 3089.294 uV, v_off_fin = 3066.467 uV 17:12:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.640 uVs 17:12:57 Integrated Voltage Measurement... 17:13:06 Voltage Offset Correction: v_off_ini = 3051.284 uV, v_off_fin = 3092.612 uV 17:13:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.975 uVs 17:13:06 Integrated Voltage Measurement... 17:13:15 Voltage Offset Correction: v_off_ini = 3075.697 uV, v_off_fin = 3089.742 uV 17:13:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.527 uVs 17:13:15 Integrated Voltage Measurement... 17:13:24 Voltage Offset Correction: v_off_ini = 3081.064 uV, v_off_fin = 3073.894 uV 17:13:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.939 uVs 17:13:24 Integrated Voltage Measurement... 17:13:33 Voltage Offset Correction: v_off_ini = 3072.870 uV, v_off_fin = 3062.732 uV 17:13:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.537 uVs 17:13:33 Integrated Voltage Measurement... 17:13:42 Voltage Offset Correction: v_off_ini = 3047.803 uV, v_off_fin = 3066.189 uV 17:13:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.836 uVs 17:13:46 I1X Average and RMS of Measurements VT = -96.742 +- 14.703 uVs I1X = 19.348 +- 2.941 uTm 17:13:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:13:53 Integrated Voltage Measurement... 17:14:02 Voltage Offset Correction: v_off_ini = 3008.655 uV, v_off_fin = 3024.250 uV 17:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.078 uVs 17:14:02 Integrated Voltage Measurement... 17:14:11 Voltage Offset Correction: v_off_ini = 3056.717 uV, v_off_fin = 3066.779 uV 17:14:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.536 uVs 17:14:11 Integrated Voltage Measurement... 17:14:20 Voltage Offset Correction: v_off_ini = 3068.473 uV, v_off_fin = 3070.600 uV 17:14:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.356 uVs 17:14:20 Integrated Voltage Measurement... 17:14:29 Voltage Offset Correction: v_off_ini = 3080.718 uV, v_off_fin = 3085.999 uV 17:14:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.086 uVs 17:14:29 Integrated Voltage Measurement... 17:14:38 Voltage Offset Correction: v_off_ini = 3055.522 uV, v_off_fin = 3056.471 uV 17:14:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.822 uVs 17:14:38 Integrated Voltage Measurement... 17:14:47 Voltage Offset Correction: v_off_ini = 3074.009 uV, v_off_fin = 3094.707 uV 17:14:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.465 uVs 17:14:51 I1Y Average and RMS of Measurements VT = -228.057 +- 8.809 uVs I1Y = -45.611 +- 1.762 uTm 17:14:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:14:59 Integrated Voltage Measurement... 17:15:08 Voltage Offset Correction: v_off_ini = 3085.104 uV, v_off_fin = 3051.980 uV 17:15:08 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -145.309 uVs 17:15:08 Integrated Voltage Measurement... 17:15:17 Voltage Offset Correction: v_off_ini = 3064.569 uV, v_off_fin = 3072.982 uV 17:15:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.052 uVs 17:15:17 Integrated Voltage Measurement... 17:15:26 Voltage Offset Correction: v_off_ini = 3042.867 uV, v_off_fin = 3024.671 uV 17:15:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.087 uVs 17:15:26 Integrated Voltage Measurement... 17:15:35 Voltage Offset Correction: v_off_ini = 3032.578 uV, v_off_fin = 3051.748 uV 17:15:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.814 uVs 17:15:35 Integrated Voltage Measurement... 17:15:44 Voltage Offset Correction: v_off_ini = 3034.284 uV, v_off_fin = 3023.557 uV 17:15:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.925 uVs 17:15:44 Integrated Voltage Measurement... 17:15:53 Voltage Offset Correction: v_off_ini = 3016.673 uV, v_off_fin = 3041.697 uV 17:15:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.188 uVs 17:15:55 I2X Average and RMS of Measurements VT = -121.729 +- 12.910 uVs I2X = 11.199 +- 1.188 uTm^2 17:16:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:16:03 Integrated Voltage Measurement... 17:16:12 Voltage Offset Correction: v_off_ini = 3032.768 uV, v_off_fin = 3036.197 uV 17:16:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.899 uVs 17:16:12 Integrated Voltage Measurement... 17:16:21 Voltage Offset Correction: v_off_ini = 3022.268 uV, v_off_fin = 3039.223 uV 17:16:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 338.407 uVs 17:16:21 Integrated Voltage Measurement... 17:16:30 Voltage Offset Correction: v_off_ini = 3063.643 uV, v_off_fin = 3059.332 uV 17:16:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -391.575 uVs 17:16:30 Integrated Voltage Measurement... 17:16:39 Voltage Offset Correction: v_off_ini = 3071.528 uV, v_off_fin = 3091.865 uV 17:16:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.303 uVs 17:16:39 Integrated Voltage Measurement... 17:16:48 Voltage Offset Correction: v_off_ini = 3100.571 uV, v_off_fin = 3076.569 uV 17:16:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.755 uVs 17:16:48 Integrated Voltage Measurement... 17:16:57 Voltage Offset Correction: v_off_ini = 3078.596 uV, v_off_fin = 3059.374 uV 17:16:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.160 uVs 17:17:00 I2Y Average and RMS of Measurements VT = -351.350 +- 18.270 uVs I2Y = -32.324 +- 1.681 uTm^2 17:17:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:17:12 Integrated Voltage Measurement... 17:17:21 Voltage Offset Correction: v_off_ini = 3057.911 uV, v_off_fin = 3047.166 uV 17:17:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.499 uVs 17:17:21 Integrated Voltage Measurement... 17:17:30 Voltage Offset Correction: v_off_ini = 3078.339 uV, v_off_fin = 3069.482 uV 17:17:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.067 uVs 17:17:30 Integrated Voltage Measurement... 17:17:39 Voltage Offset Correction: v_off_ini = 3059.060 uV, v_off_fin = 3071.262 uV 17:17:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.468 uVs 17:17:39 Integrated Voltage Measurement... 17:17:48 Voltage Offset Correction: v_off_ini = 3050.876 uV, v_off_fin = 3049.969 uV 17:17:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.737 uVs 17:17:48 Integrated Voltage Measurement... 17:17:57 Voltage Offset Correction: v_off_ini = 3051.911 uV, v_off_fin = 3052.754 uV 17:17:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.671 uVs 17:17:57 Integrated Voltage Measurement... 17:18:06 Voltage Offset Correction: v_off_ini = 3051.780 uV, v_off_fin = 3051.403 uV 17:18:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.084 uVs 17:18:10 I1X Average and RMS of Measurements VT = -119.088 +- 11.926 uVs I1X = 23.818 +- 2.386 uTm 17:18:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:18:17 Integrated Voltage Measurement... 17:18:26 Voltage Offset Correction: v_off_ini = 3027.043 uV, v_off_fin = 3007.048 uV 17:18:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.535 uVs 17:18:26 Integrated Voltage Measurement... 17:18:35 Voltage Offset Correction: v_off_ini = 3036.795 uV, v_off_fin = 3042.577 uV 17:18:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.351 uVs 17:18:35 Integrated Voltage Measurement... 17:18:44 Voltage Offset Correction: v_off_ini = 2995.603 uV, v_off_fin = 3010.856 uV 17:18:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.102 uVs 17:18:44 Integrated Voltage Measurement... 17:18:53 Voltage Offset Correction: v_off_ini = 3037.973 uV, v_off_fin = 3047.218 uV 17:18:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.581 uVs 17:18:53 Integrated Voltage Measurement... 17:19:02 Voltage Offset Correction: v_off_ini = 3026.786 uV, v_off_fin = 3017.384 uV 17:19:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.793 uVs 17:19:02 Integrated Voltage Measurement... 17:19:10 Voltage Offset Correction: v_off_ini = 3045.066 uV, v_off_fin = 3040.711 uV 17:19:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.072 uVs 17:19:15 I1Y Average and RMS of Measurements VT = -210.072 +- 16.428 uVs I1Y = -42.014 +- 3.286 uTm 17:19:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:19:20 Integrated Voltage Measurement... 17:19:29 Voltage Offset Correction: v_off_ini = 2997.510 uV, v_off_fin = 3023.188 uV 17:19:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -134.304 uVs 17:19:29 Integrated Voltage Measurement... 17:19:38 Voltage Offset Correction: v_off_ini = 3082.562 uV, v_off_fin = 3044.256 uV 17:19:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.248 uVs 17:19:38 Integrated Voltage Measurement... 17:19:47 Voltage Offset Correction: v_off_ini = 3000.207 uV, v_off_fin = 2989.911 uV 17:19:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.531 uVs 17:19:47 Integrated Voltage Measurement... 17:19:56 Voltage Offset Correction: v_off_ini = 3017.271 uV, v_off_fin = 2957.938 uV 17:19:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.502 uVs 17:19:56 Integrated Voltage Measurement... 17:20:05 Voltage Offset Correction: v_off_ini = 2971.265 uV, v_off_fin = 2946.239 uV 17:20:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.381 uVs 17:20:05 Integrated Voltage Measurement... 17:20:14 Voltage Offset Correction: v_off_ini = 2962.406 uV, v_off_fin = 2965.758 uV 17:20:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.215 uVs 17:20:16 I2X Average and RMS of Measurements VT = -112.530 +- 15.540 uVs I2X = 10.353 +- 1.430 uTm^2 17:20:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:20:21 Integrated Voltage Measurement... 17:20:30 Voltage Offset Correction: v_off_ini = 2993.105 uV, v_off_fin = 2976.298 uV 17:20:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.143 uVs 17:20:30 Integrated Voltage Measurement... 17:20:39 Voltage Offset Correction: v_off_ini = 2954.462 uV, v_off_fin = 2982.684 uV 17:20:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.984 uVs 17:20:40 Integrated Voltage Measurement... 17:20:49 Voltage Offset Correction: v_off_ini = 2948.263 uV, v_off_fin = 2942.058 uV 17:20:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -343.464 uVs 17:20:49 Integrated Voltage Measurement... 17:20:58 Voltage Offset Correction: v_off_ini = 2979.264 uV, v_off_fin = 2930.815 uV 17:20:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.924 uVs 17:20:58 Integrated Voltage Measurement... 17:21:07 Voltage Offset Correction: v_off_ini = 2937.871 uV, v_off_fin = 2954.629 uV 17:21:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.599 uVs 17:21:07 Integrated Voltage Measurement... 17:21:16 Voltage Offset Correction: v_off_ini = 2969.474 uV, v_off_fin = 3006.773 uV 17:21:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.060 uVs 17:21:18 I2Y Average and RMS of Measurements VT = -335.196 +- 11.258 uVs I2Y = -30.838 +- 1.036 uTm^2 17:21:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:21:26 Integrated Voltage Measurement... 17:21:35 Voltage Offset Correction: v_off_ini = 2996.034 uV, v_off_fin = 2957.062 uV 17:21:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -99.920 uVs 17:21:35 Integrated Voltage Measurement... 17:21:44 Voltage Offset Correction: v_off_ini = 2957.317 uV, v_off_fin = 2984.575 uV 17:21:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.848 uVs 17:21:44 Integrated Voltage Measurement... 17:21:53 Voltage Offset Correction: v_off_ini = 2987.792 uV, v_off_fin = 2985.504 uV 17:21:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.257 uVs 17:21:53 Integrated Voltage Measurement... 17:22:02 Voltage Offset Correction: v_off_ini = 2987.479 uV, v_off_fin = 2988.298 uV 17:22:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.677 uVs 17:22:02 Integrated Voltage Measurement... 17:22:11 Voltage Offset Correction: v_off_ini = 3015.324 uV, v_off_fin = 2999.191 uV 17:22:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.832 uVs 17:22:11 Integrated Voltage Measurement... 17:22:20 Voltage Offset Correction: v_off_ini = 3029.606 uV, v_off_fin = 3028.968 uV 17:22:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.653 uVs 17:22:25 I1X Average and RMS of Measurements VT = -93.698 +- 12.645 uVs I1X = 18.740 +- 2.529 uTm 17:22:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:22:31 Integrated Voltage Measurement... 17:22:40 Voltage Offset Correction: v_off_ini = 2974.048 uV, v_off_fin = 3018.519 uV 17:22:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.395 uVs 17:22:40 Integrated Voltage Measurement... 17:22:49 Voltage Offset Correction: v_off_ini = 3040.263 uV, v_off_fin = 3056.249 uV 17:22:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.816 uVs 17:22:49 Integrated Voltage Measurement... 17:22:58 Voltage Offset Correction: v_off_ini = 3041.645 uV, v_off_fin = 3044.871 uV 17:22:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.045 uVs 17:22:58 Integrated Voltage Measurement... 17:23:07 Voltage Offset Correction: v_off_ini = 3045.112 uV, v_off_fin = 2990.395 uV 17:23:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.928 uVs 17:23:07 Integrated Voltage Measurement... 17:23:16 Voltage Offset Correction: v_off_ini = 2995.902 uV, v_off_fin = 2990.664 uV 17:23:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.829 uVs 17:23:16 Integrated Voltage Measurement... 17:23:25 Voltage Offset Correction: v_off_ini = 2987.772 uV, v_off_fin = 3007.721 uV 17:23:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.230 uVs 17:23:30 I1Y Average and RMS of Measurements VT = -232.874 +- 17.080 uVs I1Y = -46.575 +- 3.416 uTm 17:23:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:23:35 Integrated Voltage Measurement... 17:23:44 Voltage Offset Correction: v_off_ini = 3010.310 uV, v_off_fin = 3004.788 uV 17:23:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.246 uVs 17:23:44 Integrated Voltage Measurement... 17:23:53 Voltage Offset Correction: v_off_ini = 2988.609 uV, v_off_fin = 3020.477 uV 17:23:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.520 uVs 17:23:53 Integrated Voltage Measurement... 17:24:02 Voltage Offset Correction: v_off_ini = 3024.681 uV, v_off_fin = 3014.121 uV 17:24:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.451 uVs 17:24:02 Integrated Voltage Measurement... 17:24:11 Voltage Offset Correction: v_off_ini = 3003.585 uV, v_off_fin = 3011.697 uV 17:24:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 110.135 uVs 17:24:11 Integrated Voltage Measurement... 17:24:20 Voltage Offset Correction: v_off_ini = 3018.806 uV, v_off_fin = 3002.989 uV 17:24:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.917 uVs 17:24:20 Integrated Voltage Measurement... 17:24:29 Voltage Offset Correction: v_off_ini = 3005.472 uV, v_off_fin = 3003.419 uV 17:24:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.973 uVs 17:24:31 I2X Average and RMS of Measurements VT = -122.707 +- 7.072 uVs I2X = 11.289 +- 0.651 uTm^2 17:24:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:24:36 Integrated Voltage Measurement... 17:24:45 Voltage Offset Correction: v_off_ini = 3033.160 uV, v_off_fin = 3029.225 uV 17:24:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.248 uVs 17:24:45 Integrated Voltage Measurement... 17:24:54 Voltage Offset Correction: v_off_ini = 3020.770 uV, v_off_fin = 3011.193 uV 17:24:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.780 uVs 17:24:54 Integrated Voltage Measurement... 17:25:03 Voltage Offset Correction: v_off_ini = 3030.827 uV, v_off_fin = 3044.064 uV 17:25:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.350 uVs 17:25:03 Integrated Voltage Measurement... 17:25:12 Voltage Offset Correction: v_off_ini = 3059.410 uV, v_off_fin = 3035.139 uV 17:25:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.399 uVs 17:25:12 Integrated Voltage Measurement... 17:25:21 Voltage Offset Correction: v_off_ini = 3017.036 uV, v_off_fin = 3034.472 uV 17:25:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -312.775 uVs 17:25:22 Integrated Voltage Measurement... 17:25:30 Voltage Offset Correction: v_off_ini = 3001.434 uV, v_off_fin = 3038.846 uV 17:25:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.842 uVs 17:25:33 I2Y Average and RMS of Measurements VT = -310.066 +- 11.822 uVs I2Y = -28.527 +- 1.088 uTm^2 17:25:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:25:41 Integrated Voltage Measurement... 17:25:50 Voltage Offset Correction: v_off_ini = 3049.566 uV, v_off_fin = 3048.328 uV 17:25:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.619 uVs 17:25:50 Integrated Voltage Measurement... 17:25:59 Voltage Offset Correction: v_off_ini = 3043.367 uV, v_off_fin = 3035.492 uV 17:25:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.313 uVs 17:25:59 Integrated Voltage Measurement... 17:26:08 Voltage Offset Correction: v_off_ini = 3028.218 uV, v_off_fin = 3021.297 uV 17:26:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.519 uVs 17:26:08 Integrated Voltage Measurement... 17:26:17 Voltage Offset Correction: v_off_ini = 3020.684 uV, v_off_fin = 3014.654 uV 17:26:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.380 uVs 17:26:17 Integrated Voltage Measurement... 17:26:26 Voltage Offset Correction: v_off_ini = 3022.858 uV, v_off_fin = 3021.837 uV 17:26:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.941 uVs 17:26:26 Integrated Voltage Measurement... 17:26:35 Voltage Offset Correction: v_off_ini = 3017.767 uV, v_off_fin = 3025.901 uV 17:26:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.571 uVs 17:26:39 I1X Average and RMS of Measurements VT = -107.890 +- 13.482 uVs I1X = 21.578 +- 2.696 uTm 17:26:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:26:46 Integrated Voltage Measurement... 17:26:55 Voltage Offset Correction: v_off_ini = 3012.987 uV, v_off_fin = 3016.775 uV 17:26:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.156 uVs 17:26:55 Integrated Voltage Measurement... 17:27:04 Voltage Offset Correction: v_off_ini = 3029.396 uV, v_off_fin = 3030.955 uV 17:27:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.930 uVs 17:27:04 Integrated Voltage Measurement... 17:27:13 Voltage Offset Correction: v_off_ini = 3034.313 uV, v_off_fin = 3032.301 uV 17:27:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.076 uVs 17:27:13 Integrated Voltage Measurement... 17:27:22 Voltage Offset Correction: v_off_ini = 3002.047 uV, v_off_fin = 3044.454 uV 17:27:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.092 uVs 17:27:22 Integrated Voltage Measurement... 17:27:31 Voltage Offset Correction: v_off_ini = 3048.340 uV, v_off_fin = 3044.844 uV 17:27:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.097 uVs 17:27:31 Integrated Voltage Measurement... 17:27:40 Voltage Offset Correction: v_off_ini = 3010.504 uV, v_off_fin = 3048.836 uV 17:27:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.913 uVs 17:27:44 I1Y Average and RMS of Measurements VT = -219.211 +- 9.864 uVs I1Y = -43.843 +- 1.972 uTm 17:27:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:27:49 Integrated Voltage Measurement... 17:27:58 Voltage Offset Correction: v_off_ini = 3032.543 uV, v_off_fin = 3034.002 uV 17:27:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -165.090 uVs 17:27:58 Integrated Voltage Measurement... 17:28:07 Voltage Offset Correction: v_off_ini = 3040.986 uV, v_off_fin = 2995.066 uV 17:28:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.990 uVs 17:28:08 Integrated Voltage Measurement... 17:28:16 Voltage Offset Correction: v_off_ini = 2995.960 uV, v_off_fin = 3015.400 uV 17:28:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.479 uVs 17:28:17 Integrated Voltage Measurement... 17:28:26 Voltage Offset Correction: v_off_ini = 3017.310 uV, v_off_fin = 3021.678 uV 17:28:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.841 uVs 17:28:26 Integrated Voltage Measurement... 17:28:35 Voltage Offset Correction: v_off_ini = 3008.177 uV, v_off_fin = 2985.068 uV 17:28:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.474 uVs 17:28:35 Integrated Voltage Measurement... 17:28:44 Voltage Offset Correction: v_off_ini = 3041.088 uV, v_off_fin = 3034.530 uV 17:28:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.851 uVs 17:28:46 I2X Average and RMS of Measurements VT = -113.288 +- 10.727 uVs I2X = 10.423 +- 0.987 uTm^2 17:28:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:28:51 Integrated Voltage Measurement... 17:29:00 Voltage Offset Correction: v_off_ini = 3021.116 uV, v_off_fin = 3014.456 uV 17:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.254 uVs 17:29:00 Integrated Voltage Measurement... 17:29:09 Voltage Offset Correction: v_off_ini = 3013.896 uV, v_off_fin = 3037.945 uV 17:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.482 uVs 17:29:09 Integrated Voltage Measurement... 17:29:18 Voltage Offset Correction: v_off_ini = 3006.558 uV, v_off_fin = 3046.550 uV 17:29:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.160 uVs 17:29:18 Integrated Voltage Measurement... 17:29:27 Voltage Offset Correction: v_off_ini = 3078.538 uV, v_off_fin = 3078.153 uV 17:29:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.461 uVs 17:29:27 Integrated Voltage Measurement... 17:29:36 Voltage Offset Correction: v_off_ini = 3066.265 uV, v_off_fin = 3062.840 uV 17:29:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.348 uVs 17:29:36 Integrated Voltage Measurement... 17:29:45 Voltage Offset Correction: v_off_ini = 3042.161 uV, v_off_fin = 3053.406 uV 17:29:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.721 uVs 17:29:48 I2Y Average and RMS of Measurements VT = -348.738 +- 11.829 uVs I2Y = -32.084 +- 1.088 uTm^2 17:29:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:29:56 Integrated Voltage Measurement... 17:30:05 Voltage Offset Correction: v_off_ini = 3038.712 uV, v_off_fin = 3022.845 uV 17:30:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -146.557 uVs 17:30:05 Integrated Voltage Measurement... 17:30:14 Voltage Offset Correction: v_off_ini = 3038.963 uV, v_off_fin = 3042.152 uV 17:30:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.955 uVs 17:30:14 Integrated Voltage Measurement... 17:30:23 Voltage Offset Correction: v_off_ini = 3074.875 uV, v_off_fin = 3060.864 uV 17:30:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.484 uVs 17:30:23 Integrated Voltage Measurement... 17:30:32 Voltage Offset Correction: v_off_ini = 3053.878 uV, v_off_fin = 3046.539 uV 17:30:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.374 uVs 17:30:32 Integrated Voltage Measurement... 17:30:41 Voltage Offset Correction: v_off_ini = 3046.950 uV, v_off_fin = 3063.606 uV 17:30:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.561 uVs 17:30:41 Integrated Voltage Measurement... 17:30:50 Voltage Offset Correction: v_off_ini = 3057.659 uV, v_off_fin = 3074.175 uV 17:30:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.343 uVs 17:30:54 I1X Average and RMS of Measurements VT = -127.046 +- 5.231 uVs I1X = 25.410 +- 1.046 uTm 17:30:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:31:01 Integrated Voltage Measurement... 17:31:10 Voltage Offset Correction: v_off_ini = 3086.708 uV, v_off_fin = 3039.962 uV 17:31:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -240.864 uVs 17:31:10 Integrated Voltage Measurement... 17:31:19 Voltage Offset Correction: v_off_ini = 3054.605 uV, v_off_fin = 3048.745 uV 17:31:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.942 uVs 17:31:19 Integrated Voltage Measurement... 17:31:28 Voltage Offset Correction: v_off_ini = 3046.871 uV, v_off_fin = 3038.217 uV 17:31:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -199.009 uVs 17:31:28 Integrated Voltage Measurement... 17:31:37 Voltage Offset Correction: v_off_ini = 3056.356 uV, v_off_fin = 3044.883 uV 17:31:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.092 uVs 17:31:37 Integrated Voltage Measurement... 17:31:46 Voltage Offset Correction: v_off_ini = 3046.385 uV, v_off_fin = 3036.237 uV 17:31:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.701 uVs 17:31:46 Integrated Voltage Measurement... 17:31:55 Voltage Offset Correction: v_off_ini = 3054.963 uV, v_off_fin = 3054.509 uV 17:31:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.352 uVs 17:31:59 I1Y Average and RMS of Measurements VT = -209.327 +- 9.703 uVs I1Y = -41.868 +- 1.942 uTm 17:32:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:32:04 Integrated Voltage Measurement... 17:32:13 Voltage Offset Correction: v_off_ini = 3033.044 uV, v_off_fin = 3029.733 uV 17:32:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.678 uVs 17:32:13 Integrated Voltage Measurement... 17:32:22 Voltage Offset Correction: v_off_ini = 3038.719 uV, v_off_fin = 3056.295 uV 17:32:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.183 uVs 17:32:22 Integrated Voltage Measurement... 17:32:31 Voltage Offset Correction: v_off_ini = 3065.542 uV, v_off_fin = 3057.798 uV 17:32:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.732 uVs 17:32:31 Integrated Voltage Measurement... 17:32:40 Voltage Offset Correction: v_off_ini = 3063.865 uV, v_off_fin = 3078.614 uV 17:32:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.903 uVs 17:32:40 Integrated Voltage Measurement... 17:32:49 Voltage Offset Correction: v_off_ini = 3074.072 uV, v_off_fin = 3039.136 uV 17:32:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.682 uVs 17:32:49 Integrated Voltage Measurement... 17:32:58 Voltage Offset Correction: v_off_ini = 3045.407 uV, v_off_fin = 3039.905 uV 17:32:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.370 uVs 17:33:01 I2X Average and RMS of Measurements VT = -126.591 +- 5.678 uVs I2X = 11.646 +- 0.522 uTm^2 17:33:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:33:06 Integrated Voltage Measurement... 17:33:15 Voltage Offset Correction: v_off_ini = 3039.699 uV, v_off_fin = 3022.197 uV 17:33:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.564 uVs 17:33:15 Integrated Voltage Measurement... 17:33:24 Voltage Offset Correction: v_off_ini = 3008.702 uV, v_off_fin = 3051.281 uV 17:33:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.123 uVs 17:33:24 Integrated Voltage Measurement... 17:33:33 Voltage Offset Correction: v_off_ini = 3038.409 uV, v_off_fin = 3044.681 uV 17:33:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.530 uVs 17:33:33 Integrated Voltage Measurement... 17:33:42 Voltage Offset Correction: v_off_ini = 3015.815 uV, v_off_fin = 2957.832 uV 17:33:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.819 uVs 17:33:42 Integrated Voltage Measurement... 17:33:51 Voltage Offset Correction: v_off_ini = 3008.645 uV, v_off_fin = 3019.206 uV 17:33:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.013 uVs 17:33:51 Integrated Voltage Measurement... 17:34:00 Voltage Offset Correction: v_off_ini = 3052.381 uV, v_off_fin = 3034.957 uV 17:34:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.530 uVs 17:34:02 I2Y Average and RMS of Measurements VT = -342.596 +- 3.451 uVs I2Y = -31.519 +- 0.317 uTm^2 17:34:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:34:11 Integrated Voltage Measurement... 17:34:20 Voltage Offset Correction: v_off_ini = 3047.839 uV, v_off_fin = 3061.050 uV 17:34:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.689 uVs 17:34:20 Integrated Voltage Measurement... 17:34:29 Voltage Offset Correction: v_off_ini = 3074.093 uV, v_off_fin = 3059.776 uV 17:34:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.735 uVs 17:34:29 Integrated Voltage Measurement... 17:34:38 Voltage Offset Correction: v_off_ini = 3082.709 uV, v_off_fin = 3077.401 uV 17:34:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.835 uVs 17:34:38 Integrated Voltage Measurement... 17:34:47 Voltage Offset Correction: v_off_ini = 3075.682 uV, v_off_fin = 3085.860 uV 17:34:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.141 uVs 17:34:47 Integrated Voltage Measurement... 17:34:56 Voltage Offset Correction: v_off_ini = 3052.767 uV, v_off_fin = 3071.372 uV 17:34:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.190 uVs 17:34:56 Integrated Voltage Measurement... 17:35:05 Voltage Offset Correction: v_off_ini = 3074.267 uV, v_off_fin = 3054.971 uV 17:35:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.033 uVs 17:35:09 I1X Average and RMS of Measurements VT = -94.104 +- 13.156 uVs I1X = 18.821 +- 2.631 uTm 17:35:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:35:16 Integrated Voltage Measurement... 17:35:25 Voltage Offset Correction: v_off_ini = 3057.638 uV, v_off_fin = 3016.522 uV 17:35:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.262 uVs 17:35:25 Integrated Voltage Measurement... 17:35:34 Voltage Offset Correction: v_off_ini = 3056.117 uV, v_off_fin = 3058.546 uV 17:35:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.669 uVs 17:35:34 Integrated Voltage Measurement... 17:35:43 Voltage Offset Correction: v_off_ini = 3070.276 uV, v_off_fin = 3048.000 uV 17:35:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.008 uVs 17:35:43 Integrated Voltage Measurement... 17:35:52 Voltage Offset Correction: v_off_ini = 3046.523 uV, v_off_fin = 3081.844 uV 17:35:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.624 uVs 17:35:52 Integrated Voltage Measurement... 17:36:01 Voltage Offset Correction: v_off_ini = 3077.034 uV, v_off_fin = 3051.257 uV 17:36:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.823 uVs 17:36:01 Integrated Voltage Measurement... 17:36:10 Voltage Offset Correction: v_off_ini = 3051.409 uV, v_off_fin = 3046.530 uV 17:36:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 239.416 uVs 17:36:14 I1Y Average and RMS of Measurements VT = -217.467 +- 5.655 uVs I1Y = -43.493 +- 1.133 uTm 17:36:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:36:19 Integrated Voltage Measurement... 17:36:28 Voltage Offset Correction: v_off_ini = 3053.542 uV, v_off_fin = 3071.905 uV 17:36:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.402 uVs 17:36:28 Integrated Voltage Measurement... 17:36:37 Voltage Offset Correction: v_off_ini = 3051.292 uV, v_off_fin = 3057.894 uV 17:36:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.611 uVs 17:36:37 Integrated Voltage Measurement... 17:36:46 Voltage Offset Correction: v_off_ini = 3071.260 uV, v_off_fin = 3032.426 uV 17:36:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -142.334 uVs 17:36:46 Integrated Voltage Measurement... 17:36:55 Voltage Offset Correction: v_off_ini = 3059.420 uV, v_off_fin = 3062.946 uV 17:36:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.371 uVs 17:36:55 Integrated Voltage Measurement... 17:37:04 Voltage Offset Correction: v_off_ini = 3063.856 uV, v_off_fin = 3040.600 uV 17:37:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.381 uVs 17:37:04 Integrated Voltage Measurement... 17:37:13 Voltage Offset Correction: v_off_ini = 3042.239 uV, v_off_fin = 3046.653 uV 17:37:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.096 uVs 17:37:15 I2X Average and RMS of Measurements VT = -111.199 +- 14.444 uVs I2X = 10.231 +- 1.329 uTm^2 17:37:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:37:21 Integrated Voltage Measurement... 17:37:30 Voltage Offset Correction: v_off_ini = 3047.216 uV, v_off_fin = 3067.629 uV 17:37:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.530 uVs 17:37:30 Integrated Voltage Measurement... 17:37:39 Voltage Offset Correction: v_off_ini = 3070.081 uV, v_off_fin = 3086.924 uV 17:37:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.990 uVs 17:37:39 Integrated Voltage Measurement... 17:37:48 Voltage Offset Correction: v_off_ini = 3094.578 uV, v_off_fin = 3077.094 uV 17:37:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.242 uVs 17:37:48 Integrated Voltage Measurement... 17:37:57 Voltage Offset Correction: v_off_ini = 3060.390 uV, v_off_fin = 3070.157 uV 17:37:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.767 uVs 17:37:57 Integrated Voltage Measurement... 17:38:06 Voltage Offset Correction: v_off_ini = 3078.080 uV, v_off_fin = 3060.405 uV 17:38:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -400.884 uVs 17:38:06 Integrated Voltage Measurement... 17:38:15 Voltage Offset Correction: v_off_ini = 3096.510 uV, v_off_fin = 3072.064 uV 17:38:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.707 uVs 17:38:17 I2Y Average and RMS of Measurements VT = -362.853 +- 18.711 uVs I2Y = -33.383 +- 1.721 uTm^2 17:38:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:38:39 Integrated Voltage Measurement... 17:38:47 Voltage Offset Correction: v_off_ini = 3081.696 uV, v_off_fin = 3079.416 uV 17:38:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -105.833 uVs 17:38:48 Integrated Voltage Measurement... 17:38:56 Voltage Offset Correction: v_off_ini = 3063.862 uV, v_off_fin = 3055.527 uV 17:38:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.764 uVs 17:38:57 Integrated Voltage Measurement... 17:39:06 Voltage Offset Correction: v_off_ini = 3054.051 uV, v_off_fin = 3048.598 uV 17:39:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.012 uVs 17:39:06 Integrated Voltage Measurement... 17:39:15 Voltage Offset Correction: v_off_ini = 3060.784 uV, v_off_fin = 3068.595 uV 17:39:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 3.532 uVs 17:39:15 Integrated Voltage Measurement... 17:39:24 Voltage Offset Correction: v_off_ini = 3060.728 uV, v_off_fin = 3079.452 uV 17:39:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.931 uVs 17:39:24 Integrated Voltage Measurement... 17:39:33 Voltage Offset Correction: v_off_ini = 3098.731 uV, v_off_fin = 3088.934 uV 17:39:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.253 uVs 17:39:37 I1X Average and RMS of Measurements VT = -93.554 +- 34.637 uVs I1X = 18.713 +- 6.929 uTm 17:39:39 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:39:44 Integrated Voltage Measurement... 17:39:52 Voltage Offset Correction: v_off_ini = 3089.475 uV, v_off_fin = 3074.279 uV 17:39:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.696 uVs 17:39:53 Integrated Voltage Measurement... 17:40:01 Voltage Offset Correction: v_off_ini = 3049.301 uV, v_off_fin = 3051.851 uV 17:40:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.588 uVs 17:40:02 Integrated Voltage Measurement... 17:40:10 Voltage Offset Correction: v_off_ini = 3049.329 uV, v_off_fin = 3048.678 uV 17:40:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.417 uVs 17:40:11 Integrated Voltage Measurement... 17:40:19 Voltage Offset Correction: v_off_ini = 3069.791 uV, v_off_fin = 3066.582 uV 17:40:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.027 uVs 17:40:20 Integrated Voltage Measurement... 17:40:28 Voltage Offset Correction: v_off_ini = 3068.709 uV, v_off_fin = 3072.657 uV 17:40:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.061 uVs 17:40:29 Integrated Voltage Measurement... 17:40:37 Voltage Offset Correction: v_off_ini = 3067.493 uV, v_off_fin = 3072.227 uV 17:40:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.482 uVs 17:40:42 I1Y Average and RMS of Measurements VT = -196.378 +- 11.818 uVs I1Y = -39.276 +- 2.364 uTm 17:40:47 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:40:49 Integrated Voltage Measurement... 17:40:58 Voltage Offset Correction: v_off_ini = 3048.668 uV, v_off_fin = 3030.233 uV 17:40:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.611 uVs 17:40:58 Integrated Voltage Measurement... 17:41:07 Voltage Offset Correction: v_off_ini = 3061.634 uV, v_off_fin = 3038.203 uV 17:41:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.411 uVs 17:41:07 Integrated Voltage Measurement... 17:41:16 Voltage Offset Correction: v_off_ini = 3082.648 uV, v_off_fin = 3076.880 uV 17:41:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.592 uVs 17:41:16 Integrated Voltage Measurement... 17:41:25 Voltage Offset Correction: v_off_ini = 3067.861 uV, v_off_fin = 3068.357 uV 17:41:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.767 uVs 17:41:26 Integrated Voltage Measurement... 17:41:35 Voltage Offset Correction: v_off_ini = 3048.428 uV, v_off_fin = 3030.062 uV 17:41:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.625 uVs 17:41:35 Integrated Voltage Measurement... 17:41:44 Voltage Offset Correction: v_off_ini = 3012.212 uV, v_off_fin = 3060.331 uV 17:41:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 141.709 uVs 17:41:46 I2X Average and RMS of Measurements VT = -116.619 +- 12.135 uVs I2X = 10.729 +- 1.117 uTm^2 17:41:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:41:54 Integrated Voltage Measurement... 17:42:03 Voltage Offset Correction: v_off_ini = 3051.812 uV, v_off_fin = 3029.927 uV 17:42:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.314 uVs 17:42:03 Integrated Voltage Measurement... 17:42:12 Voltage Offset Correction: v_off_ini = 3026.099 uV, v_off_fin = 3035.745 uV 17:42:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 362.470 uVs 17:42:12 Integrated Voltage Measurement... 17:42:21 Voltage Offset Correction: v_off_ini = 3049.709 uV, v_off_fin = 3022.504 uV 17:42:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.170 uVs 17:42:21 Integrated Voltage Measurement... 17:42:30 Voltage Offset Correction: v_off_ini = 3028.461 uV, v_off_fin = 3025.738 uV 17:42:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.529 uVs 17:42:30 Integrated Voltage Measurement... 17:42:39 Voltage Offset Correction: v_off_ini = 3045.465 uV, v_off_fin = 3008.034 uV 17:42:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.910 uVs 17:42:39 Integrated Voltage Measurement... 17:42:48 Voltage Offset Correction: v_off_ini = 3004.005 uV, v_off_fin = 3016.137 uV 17:42:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.591 uVs 17:42:50 I2Y Average and RMS of Measurements VT = -300.497 +- 9.793 uVs I2Y = -27.646 +- 0.902 uTm^2 17:42:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:42:59 Integrated Voltage Measurement... 17:43:08 Voltage Offset Correction: v_off_ini = 3038.915 uV, v_off_fin = 3006.682 uV 17:43:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.097 uVs 17:43:08 Integrated Voltage Measurement... 17:43:17 Voltage Offset Correction: v_off_ini = 3007.196 uV, v_off_fin = 3046.849 uV 17:43:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.327 uVs 17:43:17 Integrated Voltage Measurement... 17:43:26 Voltage Offset Correction: v_off_ini = 3059.717 uV, v_off_fin = 3045.963 uV 17:43:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.812 uVs 17:43:26 Integrated Voltage Measurement... 17:43:35 Voltage Offset Correction: v_off_ini = 3023.812 uV, v_off_fin = 3048.630 uV 17:43:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.817 uVs 17:43:35 Integrated Voltage Measurement... 17:43:44 Voltage Offset Correction: v_off_ini = 3042.466 uV, v_off_fin = 3049.940 uV 17:43:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.650 uVs 17:43:44 Integrated Voltage Measurement... 17:43:53 Voltage Offset Correction: v_off_ini = 3011.690 uV, v_off_fin = 3047.401 uV 17:43:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.599 uVs 17:43:57 I1X Average and RMS of Measurements VT = -116.217 +- 11.651 uVs I1X = 23.244 +- 2.331 uTm 17:44:00 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:44:04 Integrated Voltage Measurement... 17:44:13 Voltage Offset Correction: v_off_ini = 3039.524 uV, v_off_fin = 3044.347 uV 17:44:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.200 uVs 17:44:13 Integrated Voltage Measurement... 17:44:22 Voltage Offset Correction: v_off_ini = 3055.886 uV, v_off_fin = 3057.741 uV 17:44:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.093 uVs 17:44:22 Integrated Voltage Measurement... 17:44:31 Voltage Offset Correction: v_off_ini = 3045.066 uV, v_off_fin = 2992.527 uV 17:44:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.248 uVs 17:44:31 Integrated Voltage Measurement... 17:44:40 Voltage Offset Correction: v_off_ini = 3022.436 uV, v_off_fin = 3000.756 uV 17:44:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.006 uVs 17:44:40 Integrated Voltage Measurement... 17:44:49 Voltage Offset Correction: v_off_ini = 3003.248 uV, v_off_fin = 3005.293 uV 17:44:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.621 uVs 17:44:49 Integrated Voltage Measurement... 17:44:58 Voltage Offset Correction: v_off_ini = 2996.963 uV, v_off_fin = 2996.356 uV 17:44:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.411 uVs 17:45:02 I1Y Average and RMS of Measurements VT = -208.263 +- 5.935 uVs I1Y = -41.653 +- 1.187 uTm 17:45:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:45:10 Integrated Voltage Measurement... 17:45:19 Voltage Offset Correction: v_off_ini = 2977.980 uV, v_off_fin = 2984.228 uV 17:45:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -82.598 uVs 17:45:19 Integrated Voltage Measurement... 17:45:28 Voltage Offset Correction: v_off_ini = 3017.961 uV, v_off_fin = 3038.835 uV 17:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.732 uVs 17:45:28 Integrated Voltage Measurement... 17:45:37 Voltage Offset Correction: v_off_ini = 3039.873 uV, v_off_fin = 3017.320 uV 17:45:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -152.081 uVs 17:45:37 Integrated Voltage Measurement... 17:45:46 Voltage Offset Correction: v_off_ini = 3004.286 uV, v_off_fin = 3010.807 uV 17:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.568 uVs 17:45:46 Integrated Voltage Measurement... 17:45:55 Voltage Offset Correction: v_off_ini = 3026.623 uV, v_off_fin = 3014.610 uV 17:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.487 uVs 17:45:55 Integrated Voltage Measurement... 17:46:04 Voltage Offset Correction: v_off_ini = 3007.610 uV, v_off_fin = 3033.782 uV 17:46:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 110.599 uVs 17:46:06 I2X Average and RMS of Measurements VT = -115.344 +- 12.144 uVs I2X = 10.612 +- 1.118 uTm^2 17:46:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:46:14 Integrated Voltage Measurement... 17:46:23 Voltage Offset Correction: v_off_ini = 3010.728 uV, v_off_fin = 3042.243 uV 17:46:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.781 uVs 17:46:23 Integrated Voltage Measurement... 17:46:32 Voltage Offset Correction: v_off_ini = 3037.428 uV, v_off_fin = 3023.720 uV 17:46:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.666 uVs 17:46:32 Integrated Voltage Measurement... 17:46:41 Voltage Offset Correction: v_off_ini = 3028.536 uV, v_off_fin = 3023.170 uV 17:46:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.978 uVs 17:46:41 Integrated Voltage Measurement... 17:46:50 Voltage Offset Correction: v_off_ini = 2997.576 uV, v_off_fin = 2975.361 uV 17:46:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.168 uVs 17:46:50 Integrated Voltage Measurement... 17:46:59 Voltage Offset Correction: v_off_ini = 2986.535 uV, v_off_fin = 2996.087 uV 17:46:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.516 uVs 17:46:59 Integrated Voltage Measurement... 17:47:08 Voltage Offset Correction: v_off_ini = 3011.025 uV, v_off_fin = 3027.442 uV 17:47:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.378 uVs 17:47:11 I2Y Average and RMS of Measurements VT = -316.415 +- 9.166 uVs I2Y = -29.110 +- 0.843 uTm^2 17:47:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:47:20 Integrated Voltage Measurement... 17:47:29 Voltage Offset Correction: v_off_ini = 2972.067 uV, v_off_fin = 3024.878 uV 17:47:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -63.168 uVs 17:47:29 Integrated Voltage Measurement... 17:47:38 Voltage Offset Correction: v_off_ini = 2989.397 uV, v_off_fin = 3015.189 uV 17:47:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.060 uVs 17:47:38 Integrated Voltage Measurement... 17:47:47 Voltage Offset Correction: v_off_ini = 3012.037 uV, v_off_fin = 3015.893 uV 17:47:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.361 uVs 17:47:47 Integrated Voltage Measurement... 17:47:56 Voltage Offset Correction: v_off_ini = 3034.118 uV, v_off_fin = 3039.773 uV 17:47:56 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 100.728 uVs 17:47:56 Integrated Voltage Measurement... 17:48:05 Voltage Offset Correction: v_off_ini = 3020.573 uV, v_off_fin = 3034.332 uV 17:48:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.885 uVs 17:48:05 Integrated Voltage Measurement... 17:48:14 Voltage Offset Correction: v_off_ini = 3063.890 uV, v_off_fin = 3064.596 uV 17:48:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.480 uVs 17:48:18 I1X Average and RMS of Measurements VT = -96.447 +- 5.493 uVs I1X = 19.292 +- 1.100 uTm 17:48:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:48:25 Integrated Voltage Measurement... 17:48:34 Voltage Offset Correction: v_off_ini = 3025.568 uV, v_off_fin = 3012.432 uV 17:48:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.923 uVs 17:48:34 Integrated Voltage Measurement... 17:48:43 Voltage Offset Correction: v_off_ini = 2987.316 uV, v_off_fin = 3015.289 uV 17:48:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.856 uVs 17:48:43 Integrated Voltage Measurement... 17:48:52 Voltage Offset Correction: v_off_ini = 3069.351 uV, v_off_fin = 3065.518 uV 17:48:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.194 uVs 17:48:52 Integrated Voltage Measurement... 17:49:01 Voltage Offset Correction: v_off_ini = 3060.548 uV, v_off_fin = 3036.315 uV 17:49:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.122 uVs 17:49:01 Integrated Voltage Measurement... 17:49:10 Voltage Offset Correction: v_off_ini = 3024.567 uV, v_off_fin = 3030.258 uV 17:49:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.361 uVs 17:49:10 Integrated Voltage Measurement... 17:49:19 Voltage Offset Correction: v_off_ini = 3068.958 uV, v_off_fin = 3069.219 uV 17:49:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.494 uVs 17:49:23 I1Y Average and RMS of Measurements VT = -197.325 +- 10.525 uVs I1Y = -39.465 +- 2.105 uTm 17:49:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:49:30 Integrated Voltage Measurement... 17:49:39 Voltage Offset Correction: v_off_ini = 3038.361 uV, v_off_fin = 3039.757 uV 17:49:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.206 uVs 17:49:39 Integrated Voltage Measurement... 17:49:48 Voltage Offset Correction: v_off_ini = 3057.138 uV, v_off_fin = 3064.802 uV 17:49:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.367 uVs 17:49:49 Integrated Voltage Measurement... 17:49:57 Voltage Offset Correction: v_off_ini = 3039.166 uV, v_off_fin = 3067.372 uV 17:49:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -62.994 uVs 17:49:58 Integrated Voltage Measurement... 17:50:07 Voltage Offset Correction: v_off_ini = 3060.055 uV, v_off_fin = 3077.612 uV 17:50:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.179 uVs 17:50:07 Integrated Voltage Measurement... 17:50:16 Voltage Offset Correction: v_off_ini = 3027.804 uV, v_off_fin = 3019.620 uV 17:50:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.224 uVs 17:50:16 Integrated Voltage Measurement... 17:50:25 Voltage Offset Correction: v_off_ini = 3042.571 uV, v_off_fin = 3051.879 uV 17:50:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.374 uVs 17:50:27 I2X Average and RMS of Measurements VT = -107.557 +- 24.690 uVs I2X = 9.895 +- 2.271 uTm^2 17:50:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:50:35 Integrated Voltage Measurement... 17:50:44 Voltage Offset Correction: v_off_ini = 3065.431 uV, v_off_fin = 3035.731 uV 17:50:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.412 uVs 17:50:44 Integrated Voltage Measurement... 17:50:53 Voltage Offset Correction: v_off_ini = 3048.583 uV, v_off_fin = 3034.780 uV 17:50:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.818 uVs 17:50:53 Integrated Voltage Measurement... 17:51:02 Voltage Offset Correction: v_off_ini = 3046.475 uV, v_off_fin = 3028.208 uV 17:51:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.832 uVs 17:51:02 Integrated Voltage Measurement... 17:51:11 Voltage Offset Correction: v_off_ini = 3052.013 uV, v_off_fin = 3065.716 uV 17:51:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.024 uVs 17:51:11 Integrated Voltage Measurement... 17:51:20 Voltage Offset Correction: v_off_ini = 3035.024 uV, v_off_fin = 3026.632 uV 17:51:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.035 uVs 17:51:20 Integrated Voltage Measurement... 17:51:29 Voltage Offset Correction: v_off_ini = 3017.491 uV, v_off_fin = 3035.181 uV 17:51:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.305 uVs 17:51:31 I2Y Average and RMS of Measurements VT = -316.571 +- 8.865 uVs I2Y = -29.125 +- 0.816 uTm^2 17:51:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:51:40 Integrated Voltage Measurement... 17:51:49 Voltage Offset Correction: v_off_ini = 3068.709 uV, v_off_fin = 3035.510 uV 17:51:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.890 uVs 17:51:49 Integrated Voltage Measurement... 17:51:58 Voltage Offset Correction: v_off_ini = 3023.405 uV, v_off_fin = 3051.230 uV 17:51:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.231 uVs 17:51:58 Integrated Voltage Measurement... 17:52:07 Voltage Offset Correction: v_off_ini = 3010.416 uV, v_off_fin = 3022.520 uV 17:52:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.142 uVs 17:52:07 Integrated Voltage Measurement... 17:52:16 Voltage Offset Correction: v_off_ini = 3026.775 uV, v_off_fin = 3020.144 uV 17:52:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.331 uVs 17:52:16 Integrated Voltage Measurement... 17:52:25 Voltage Offset Correction: v_off_ini = 3055.069 uV, v_off_fin = 3070.609 uV 17:52:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.057 uVs 17:52:25 Integrated Voltage Measurement... 17:52:34 Voltage Offset Correction: v_off_ini = 3055.739 uV, v_off_fin = 3050.903 uV 17:52:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.942 uVs 17:52:38 I1X Average and RMS of Measurements VT = -97.932 +- 8.949 uVs I1X = 19.586 +- 1.790 uTm 17:52:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:52:45 Integrated Voltage Measurement... 17:52:54 Voltage Offset Correction: v_off_ini = 3052.650 uV, v_off_fin = 3045.485 uV 17:52:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -210.100 uVs 17:52:54 Integrated Voltage Measurement... 17:53:03 Voltage Offset Correction: v_off_ini = 3090.291 uV, v_off_fin = 3097.054 uV 17:53:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.424 uVs 17:53:03 Integrated Voltage Measurement... 17:53:12 Voltage Offset Correction: v_off_ini = 3077.465 uV, v_off_fin = 3038.319 uV 17:53:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.388 uVs 17:53:12 Integrated Voltage Measurement... 17:53:21 Voltage Offset Correction: v_off_ini = 3060.483 uV, v_off_fin = 3052.395 uV 17:53:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.280 uVs 17:53:21 Integrated Voltage Measurement... 17:53:30 Voltage Offset Correction: v_off_ini = 3038.557 uV, v_off_fin = 3057.725 uV 17:53:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.231 uVs 17:53:30 Integrated Voltage Measurement... 17:53:39 Voltage Offset Correction: v_off_ini = 3047.706 uV, v_off_fin = 3044.012 uV 17:53:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.032 uVs 17:53:43 I1Y Average and RMS of Measurements VT = -195.243 +- 5.430 uVs I1Y = -39.049 +- 1.087 uTm 17:53:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:53:51 Integrated Voltage Measurement... 17:54:00 Voltage Offset Correction: v_off_ini = 3030.209 uV, v_off_fin = 3030.930 uV 17:54:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.886 uVs 17:54:00 Integrated Voltage Measurement... 17:54:09 Voltage Offset Correction: v_off_ini = 3038.262 uV, v_off_fin = 3019.754 uV 17:54:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.604 uVs 17:54:09 Integrated Voltage Measurement... 17:54:18 Voltage Offset Correction: v_off_ini = 3037.180 uV, v_off_fin = 3053.692 uV 17:54:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.056 uVs 17:54:18 Integrated Voltage Measurement... 17:54:27 Voltage Offset Correction: v_off_ini = 3038.337 uV, v_off_fin = 3053.314 uV 17:54:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.158 uVs 17:54:27 Integrated Voltage Measurement... 17:54:36 Voltage Offset Correction: v_off_ini = 3024.017 uV, v_off_fin = 3043.148 uV 17:54:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.201 uVs 17:54:36 Integrated Voltage Measurement... 17:54:45 Voltage Offset Correction: v_off_ini = 3020.345 uV, v_off_fin = 3029.027 uV 17:54:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.200 uVs 17:54:48 I2X Average and RMS of Measurements VT = -113.851 +- 12.022 uVs I2X = 10.474 +- 1.106 uTm^2 17:54:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:54:55 Integrated Voltage Measurement... 17:55:04 Voltage Offset Correction: v_off_ini = 3048.352 uV, v_off_fin = 3061.042 uV 17:55:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.069 uVs 17:55:04 Integrated Voltage Measurement... 17:55:13 Voltage Offset Correction: v_off_ini = 3063.324 uV, v_off_fin = 3057.110 uV 17:55:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.274 uVs 17:55:13 Integrated Voltage Measurement... 17:55:22 Voltage Offset Correction: v_off_ini = 3061.426 uV, v_off_fin = 3087.676 uV 17:55:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.484 uVs 17:55:22 Integrated Voltage Measurement... 17:55:31 Voltage Offset Correction: v_off_ini = 3059.021 uV, v_off_fin = 3067.970 uV 17:55:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.099 uVs 17:55:31 Integrated Voltage Measurement... 17:55:40 Voltage Offset Correction: v_off_ini = 3052.278 uV, v_off_fin = 3063.935 uV 17:55:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.459 uVs 17:55:40 Integrated Voltage Measurement... 17:55:49 Voltage Offset Correction: v_off_ini = 3054.119 uV, v_off_fin = 3029.411 uV 17:55:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.303 uVs 17:55:52 I2Y Average and RMS of Measurements VT = -334.281 +- 6.990 uVs I2Y = -30.754 +- 0.643 uTm^2 17:55:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:56:01 Integrated Voltage Measurement... 17:56:10 Voltage Offset Correction: v_off_ini = 3073.571 uV, v_off_fin = 3080.956 uV 17:56:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.763 uVs 17:56:10 Integrated Voltage Measurement... 17:56:19 Voltage Offset Correction: v_off_ini = 3077.378 uV, v_off_fin = 3075.186 uV 17:56:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.095 uVs 17:56:19 Integrated Voltage Measurement... 17:56:28 Voltage Offset Correction: v_off_ini = 3102.048 uV, v_off_fin = 3098.298 uV 17:56:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.568 uVs 17:56:28 Integrated Voltage Measurement... 17:56:37 Voltage Offset Correction: v_off_ini = 3075.262 uV, v_off_fin = 3091.403 uV 17:56:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.386 uVs 17:56:37 Integrated Voltage Measurement... 17:56:46 Voltage Offset Correction: v_off_ini = 3075.157 uV, v_off_fin = 3075.071 uV 17:56:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.687 uVs 17:56:46 Integrated Voltage Measurement... 17:56:55 Voltage Offset Correction: v_off_ini = 3098.004 uV, v_off_fin = 3105.734 uV 17:56:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.010 uVs 17:56:59 I1X Average and RMS of Measurements VT = -112.585 +- 23.291 uVs I1X = 22.517 +- 4.658 uTm 17:57:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:57:06 Integrated Voltage Measurement... 17:57:15 Voltage Offset Correction: v_off_ini = 3070.478 uV, v_off_fin = 3056.564 uV 17:57:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.348 uVs 17:57:15 Integrated Voltage Measurement... 17:57:24 Voltage Offset Correction: v_off_ini = 3083.841 uV, v_off_fin = 3072.275 uV 17:57:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.817 uVs 17:57:24 Integrated Voltage Measurement... 17:57:33 Voltage Offset Correction: v_off_ini = 3070.178 uV, v_off_fin = 3067.560 uV 17:57:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.607 uVs 17:57:33 Integrated Voltage Measurement... 17:57:42 Voltage Offset Correction: v_off_ini = 3028.218 uV, v_off_fin = 3075.155 uV 17:57:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.347 uVs 17:57:42 Integrated Voltage Measurement... 17:57:51 Voltage Offset Correction: v_off_ini = 3072.003 uV, v_off_fin = 3049.819 uV 17:57:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.024 uVs 17:57:51 Integrated Voltage Measurement... 17:58:00 Voltage Offset Correction: v_off_ini = 3057.997 uV, v_off_fin = 3053.744 uV 17:58:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.141 uVs 17:58:04 I1Y Average and RMS of Measurements VT = -206.047 +- 4.491 uVs I1Y = -41.209 +- 0.898 uTm 17:58:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:58:11 Integrated Voltage Measurement... 17:58:20 Voltage Offset Correction: v_off_ini = 3066.884 uV, v_off_fin = 3058.369 uV 17:58:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.371 uVs 17:58:20 Integrated Voltage Measurement... 17:58:29 Voltage Offset Correction: v_off_ini = 3049.717 uV, v_off_fin = 3041.443 uV 17:58:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.458 uVs 17:58:30 Integrated Voltage Measurement... 17:58:39 Voltage Offset Correction: v_off_ini = 3064.541 uV, v_off_fin = 3064.545 uV 17:58:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.096 uVs 17:58:39 Integrated Voltage Measurement... 17:58:48 Voltage Offset Correction: v_off_ini = 3011.545 uV, v_off_fin = 3065.100 uV 17:58:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 44.022 uVs 17:58:48 Integrated Voltage Measurement... 17:58:57 Voltage Offset Correction: v_off_ini = 3089.951 uV, v_off_fin = 3067.100 uV 17:58:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -163.781 uVs 17:58:57 Integrated Voltage Measurement... 17:59:06 Voltage Offset Correction: v_off_ini = 3084.096 uV, v_off_fin = 3081.651 uV 17:59:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.204 uVs 17:59:08 I2X Average and RMS of Measurements VT = -121.655 +- 32.527 uVs I2X = 11.192 +- 2.992 uTm^2 17:59:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:59:16 Integrated Voltage Measurement... 17:59:25 Voltage Offset Correction: v_off_ini = 3095.471 uV, v_off_fin = 3055.244 uV 17:59:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.850 uVs 17:59:25 Integrated Voltage Measurement... 17:59:34 Voltage Offset Correction: v_off_ini = 3097.094 uV, v_off_fin = 3062.177 uV 17:59:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.207 uVs 17:59:34 Integrated Voltage Measurement... 17:59:43 Voltage Offset Correction: v_off_ini = 3116.465 uV, v_off_fin = 3084.908 uV 17:59:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -347.482 uVs 17:59:43 Integrated Voltage Measurement... 17:59:52 Voltage Offset Correction: v_off_ini = 3088.064 uV, v_off_fin = 3091.591 uV 17:59:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 313.787 uVs 17:59:52 Integrated Voltage Measurement... 18:00:01 Voltage Offset Correction: v_off_ini = 3077.810 uV, v_off_fin = 3078.234 uV 18:00:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -352.282 uVs 18:00:01 Integrated Voltage Measurement... 18:00:10 Voltage Offset Correction: v_off_ini = 3064.512 uV, v_off_fin = 3087.348 uV 18:00:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.448 uVs 18:00:12 I2Y Average and RMS of Measurements VT = -328.676 +- 7.212 uVs I2Y = -30.239 +- 0.664 uTm^2 18:00:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:00:24 Integrated Voltage Measurement... 18:00:33 Voltage Offset Correction: v_off_ini = 3067.079 uV, v_off_fin = 3071.802 uV 18:00:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -139.073 uVs 18:00:33 Integrated Voltage Measurement... 18:00:42 Voltage Offset Correction: v_off_ini = 3065.990 uV, v_off_fin = 3095.416 uV 18:00:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.685 uVs 18:00:42 Integrated Voltage Measurement... 18:00:51 Voltage Offset Correction: v_off_ini = 3087.754 uV, v_off_fin = 3064.173 uV 18:00:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.308 uVs 18:00:51 Integrated Voltage Measurement... 18:01:00 Voltage Offset Correction: v_off_ini = 3055.005 uV, v_off_fin = 3076.307 uV 18:01:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.050 uVs 18:01:00 Integrated Voltage Measurement... 18:01:09 Voltage Offset Correction: v_off_ini = 3108.876 uV, v_off_fin = 3069.589 uV 18:01:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.543 uVs 18:01:09 Integrated Voltage Measurement... 18:01:18 Voltage Offset Correction: v_off_ini = 3068.070 uV, v_off_fin = 3079.702 uV 18:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.732 uVs 18:01:23 I1X Average and RMS of Measurements VT = -108.399 +- 11.152 uVs I1X = 21.680 +- 2.231 uTm 18:01:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:01:29 Integrated Voltage Measurement... 18:01:38 Voltage Offset Correction: v_off_ini = 3103.716 uV, v_off_fin = 3080.508 uV 18:01:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.744 uVs 18:01:38 Integrated Voltage Measurement... 18:01:47 Voltage Offset Correction: v_off_ini = 3076.626 uV, v_off_fin = 3122.072 uV 18:01:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.149 uVs 18:01:47 Integrated Voltage Measurement... 18:01:56 Voltage Offset Correction: v_off_ini = 3110.929 uV, v_off_fin = 3083.503 uV 18:01:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.373 uVs 18:01:56 Integrated Voltage Measurement... 18:02:05 Voltage Offset Correction: v_off_ini = 3101.931 uV, v_off_fin = 3099.428 uV 18:02:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.567 uVs 18:02:05 Integrated Voltage Measurement... 18:02:14 Voltage Offset Correction: v_off_ini = 3115.094 uV, v_off_fin = 3070.094 uV 18:02:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.643 uVs 18:02:14 Integrated Voltage Measurement... 18:02:23 Voltage Offset Correction: v_off_ini = 3090.355 uV, v_off_fin = 3049.434 uV 18:02:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.819 uVs 18:02:27 I1Y Average and RMS of Measurements VT = -211.716 +- 26.857 uVs I1Y = -42.343 +- 5.371 uTm 18:02:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:02:33 Integrated Voltage Measurement... 18:02:42 Voltage Offset Correction: v_off_ini = 3066.829 uV, v_off_fin = 3066.461 uV 18:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.708 uVs 18:02:42 Integrated Voltage Measurement... 18:02:51 Voltage Offset Correction: v_off_ini = 3098.322 uV, v_off_fin = 3145.626 uV 18:02:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.505 uVs 18:02:51 Integrated Voltage Measurement... 18:03:00 Voltage Offset Correction: v_off_ini = 3133.140 uV, v_off_fin = 3116.598 uV 18:03:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.574 uVs 18:03:00 Integrated Voltage Measurement... 18:03:09 Voltage Offset Correction: v_off_ini = 3090.858 uV, v_off_fin = 3137.716 uV 18:03:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.253 uVs 18:03:09 Integrated Voltage Measurement... 18:03:18 Voltage Offset Correction: v_off_ini = 3113.837 uV, v_off_fin = 3107.797 uV 18:03:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.762 uVs 18:03:18 Integrated Voltage Measurement... 18:03:27 Voltage Offset Correction: v_off_ini = 3120.909 uV, v_off_fin = 3125.559 uV 18:03:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.474 uVs 18:03:29 I2X Average and RMS of Measurements VT = -115.546 +- 5.522 uVs I2X = 10.630 +- 0.508 uTm^2 18:03:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:03:34 Integrated Voltage Measurement... 18:03:43 Voltage Offset Correction: v_off_ini = 3103.321 uV, v_off_fin = 3122.854 uV 18:03:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.263 uVs 18:03:43 Integrated Voltage Measurement... 18:03:52 Voltage Offset Correction: v_off_ini = 3103.767 uV, v_off_fin = 3134.345 uV 18:03:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.442 uVs 18:03:52 Integrated Voltage Measurement... 18:04:01 Voltage Offset Correction: v_off_ini = 3117.081 uV, v_off_fin = 3122.274 uV 18:04:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.027 uVs 18:04:01 Integrated Voltage Measurement... 18:04:10 Voltage Offset Correction: v_off_ini = 3092.632 uV, v_off_fin = 3112.079 uV 18:04:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.014 uVs 18:04:10 Integrated Voltage Measurement... 18:04:19 Voltage Offset Correction: v_off_ini = 3100.629 uV, v_off_fin = 3081.093 uV 18:04:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.270 uVs 18:04:19 Integrated Voltage Measurement... 18:04:28 Voltage Offset Correction: v_off_ini = 3108.882 uV, v_off_fin = 3125.774 uV 18:04:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.263 uVs 18:04:31 I2Y Average and RMS of Measurements VT = -312.380 +- 18.135 uVs I2Y = -28.739 +- 1.668 uTm^2 18:04:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:04:39 Integrated Voltage Measurement... 18:04:48 Voltage Offset Correction: v_off_ini = 3151.270 uV, v_off_fin = 3148.754 uV 18:04:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.876 uVs 18:04:48 Integrated Voltage Measurement... 18:04:57 Voltage Offset Correction: v_off_ini = 3127.264 uV, v_off_fin = 3116.654 uV 18:04:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.266 uVs 18:04:57 Integrated Voltage Measurement... 18:05:06 Voltage Offset Correction: v_off_ini = 3090.566 uV, v_off_fin = 3158.513 uV 18:05:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.491 uVs 18:05:06 Integrated Voltage Measurement... 18:05:15 Voltage Offset Correction: v_off_ini = 3143.919 uV, v_off_fin = 3130.996 uV 18:05:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.468 uVs 18:05:15 Integrated Voltage Measurement... 18:05:24 Voltage Offset Correction: v_off_ini = 3131.693 uV, v_off_fin = 3120.351 uV 18:05:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.352 uVs 18:05:24 Integrated Voltage Measurement... 18:05:33 Voltage Offset Correction: v_off_ini = 3096.617 uV, v_off_fin = 3101.179 uV 18:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.437 uVs 18:05:37 I1X Average and RMS of Measurements VT = -105.482 +- 14.081 uVs I1X = 21.097 +- 2.816 uTm 18:05:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:05:44 Integrated Voltage Measurement... 18:05:53 Voltage Offset Correction: v_off_ini = 3125.334 uV, v_off_fin = 3123.754 uV 18:05:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -181.921 uVs 18:05:53 Integrated Voltage Measurement... 18:06:02 Voltage Offset Correction: v_off_ini = 3119.617 uV, v_off_fin = 3126.689 uV 18:06:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.429 uVs 18:06:02 Integrated Voltage Measurement... 18:06:11 Voltage Offset Correction: v_off_ini = 3126.819 uV, v_off_fin = 3099.307 uV 18:06:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.833 uVs 18:06:11 Integrated Voltage Measurement... 18:06:20 Voltage Offset Correction: v_off_ini = 3100.813 uV, v_off_fin = 3100.253 uV 18:06:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.190 uVs 18:06:20 Integrated Voltage Measurement... 18:06:29 Voltage Offset Correction: v_off_ini = 3112.093 uV, v_off_fin = 3098.008 uV 18:06:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.249 uVs 18:06:29 Integrated Voltage Measurement... 18:06:38 Voltage Offset Correction: v_off_ini = 3108.175 uV, v_off_fin = 3096.111 uV 18:06:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.157 uVs 18:06:42 I1Y Average and RMS of Measurements VT = -203.630 +- 5.241 uVs I1Y = -40.727 +- 1.048 uTm 18:06:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:06:47 Integrated Voltage Measurement... 18:06:56 Voltage Offset Correction: v_off_ini = 3112.851 uV, v_off_fin = 3088.045 uV 18:06:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.942 uVs 18:06:56 Integrated Voltage Measurement... 18:07:05 Voltage Offset Correction: v_off_ini = 3107.104 uV, v_off_fin = 3114.395 uV 18:07:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.670 uVs 18:07:05 Integrated Voltage Measurement... 18:07:14 Voltage Offset Correction: v_off_ini = 3094.240 uV, v_off_fin = 3092.537 uV 18:07:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.868 uVs 18:07:14 Integrated Voltage Measurement... 18:07:23 Voltage Offset Correction: v_off_ini = 3087.612 uV, v_off_fin = 3102.231 uV 18:07:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.580 uVs 18:07:23 Integrated Voltage Measurement... 18:07:32 Voltage Offset Correction: v_off_ini = 3092.217 uV, v_off_fin = 3079.570 uV 18:07:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.279 uVs 18:07:32 Integrated Voltage Measurement... 18:07:41 Voltage Offset Correction: v_off_ini = 3064.061 uV, v_off_fin = 3093.051 uV 18:07:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.280 uVs 18:07:43 I2X Average and RMS of Measurements VT = -125.603 +- 9.297 uVs I2X = 11.555 +- 0.855 uTm^2 18:07:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:07:48 Integrated Voltage Measurement... 18:07:57 Voltage Offset Correction: v_off_ini = 3060.248 uV, v_off_fin = 3085.260 uV 18:07:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.659 uVs 18:07:57 Integrated Voltage Measurement... 18:08:06 Voltage Offset Correction: v_off_ini = 3097.401 uV, v_off_fin = 3119.540 uV 18:08:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.004 uVs 18:08:06 Integrated Voltage Measurement... 18:08:15 Voltage Offset Correction: v_off_ini = 3077.913 uV, v_off_fin = 3100.232 uV 18:08:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -269.793 uVs 18:08:15 Integrated Voltage Measurement... 18:08:24 Voltage Offset Correction: v_off_ini = 3099.278 uV, v_off_fin = 3094.381 uV 18:08:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.771 uVs 18:08:24 Integrated Voltage Measurement... 18:08:33 Voltage Offset Correction: v_off_ini = 3105.150 uV, v_off_fin = 3087.733 uV 18:08:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.146 uVs 18:08:33 Integrated Voltage Measurement... 18:08:42 Voltage Offset Correction: v_off_ini = 3105.457 uV, v_off_fin = 3121.923 uV 18:08:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.836 uVs 18:08:45 I2Y Average and RMS of Measurements VT = -324.201 +- 16.507 uVs I2Y = -29.827 +- 1.518 uTm^2 18:08:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:08:53 Integrated Voltage Measurement... 18:09:02 Voltage Offset Correction: v_off_ini = 3101.808 uV, v_off_fin = 3091.530 uV 18:09:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.614 uVs 18:09:02 Integrated Voltage Measurement... 18:09:11 Voltage Offset Correction: v_off_ini = 3074.028 uV, v_off_fin = 3088.616 uV 18:09:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.788 uVs 18:09:11 Integrated Voltage Measurement... 18:09:20 Voltage Offset Correction: v_off_ini = 3104.611 uV, v_off_fin = 3094.154 uV 18:09:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.077 uVs 18:09:20 Integrated Voltage Measurement... 18:09:29 Voltage Offset Correction: v_off_ini = 3060.476 uV, v_off_fin = 3061.456 uV 18:09:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.569 uVs 18:09:29 Integrated Voltage Measurement... 18:09:38 Voltage Offset Correction: v_off_ini = 3074.088 uV, v_off_fin = 3052.478 uV 18:09:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.858 uVs 18:09:38 Integrated Voltage Measurement... 18:09:47 Voltage Offset Correction: v_off_ini = 3046.553 uV, v_off_fin = 3100.583 uV 18:09:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 85.500 uVs 18:09:51 I1X Average and RMS of Measurements VT = -114.734 +- 2.677 uVs I1X = 22.948 +- 0.536 uTm 18:09:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:09:58 Integrated Voltage Measurement... 18:10:07 Voltage Offset Correction: v_off_ini = 3075.656 uV, v_off_fin = 3045.531 uV 18:10:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.434 uVs 18:10:07 Integrated Voltage Measurement... 18:10:16 Voltage Offset Correction: v_off_ini = 3043.863 uV, v_off_fin = 3055.167 uV 18:10:16 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 212.150 uVs 18:10:16 Integrated Voltage Measurement... 18:10:25 Voltage Offset Correction: v_off_ini = 3094.238 uV, v_off_fin = 3062.105 uV 18:10:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.132 uVs 18:10:25 Integrated Voltage Measurement... 18:10:34 Voltage Offset Correction: v_off_ini = 3086.614 uV, v_off_fin = 3094.060 uV 18:10:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.972 uVs 18:10:34 Integrated Voltage Measurement... 18:10:43 Voltage Offset Correction: v_off_ini = 3083.686 uV, v_off_fin = 3063.221 uV 18:10:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.019 uVs 18:10:43 Integrated Voltage Measurement... 18:10:52 Voltage Offset Correction: v_off_ini = 3075.379 uV, v_off_fin = 3080.194 uV 18:10:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.402 uVs 18:10:56 I1Y Average and RMS of Measurements VT = -207.685 +- 5.750 uVs I1Y = -41.538 +- 1.152 uTm 18:10:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:11:01 Integrated Voltage Measurement... 18:11:10 Voltage Offset Correction: v_off_ini = 3086.585 uV, v_off_fin = 3081.804 uV 18:11:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.821 uVs 18:11:10 Integrated Voltage Measurement... 18:11:19 Voltage Offset Correction: v_off_ini = 3095.537 uV, v_off_fin = 3116.665 uV 18:11:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.156 uVs 18:11:19 Integrated Voltage Measurement... 18:11:28 Voltage Offset Correction: v_off_ini = 3111.309 uV, v_off_fin = 3090.507 uV 18:11:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.277 uVs 18:11:28 Integrated Voltage Measurement... 18:11:37 Voltage Offset Correction: v_off_ini = 3070.732 uV, v_off_fin = 3099.335 uV 18:11:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.711 uVs 18:11:37 Integrated Voltage Measurement... 18:11:46 Voltage Offset Correction: v_off_ini = 3100.608 uV, v_off_fin = 3095.091 uV 18:11:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.755 uVs 18:11:46 Integrated Voltage Measurement... 18:11:55 Voltage Offset Correction: v_off_ini = 3108.326 uV, v_off_fin = 3118.037 uV 18:11:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.797 uVs 18:11:58 I2X Average and RMS of Measurements VT = -132.920 +- 6.142 uVs I2X = 12.229 +- 0.565 uTm^2 18:12:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:12:03 Integrated Voltage Measurement... 18:12:12 Voltage Offset Correction: v_off_ini = 3118.666 uV, v_off_fin = 3117.982 uV 18:12:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.321 uVs 18:12:12 Integrated Voltage Measurement... 18:12:21 Voltage Offset Correction: v_off_ini = 3096.765 uV, v_off_fin = 3105.715 uV 18:12:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.990 uVs 18:12:21 Integrated Voltage Measurement... 18:12:30 Voltage Offset Correction: v_off_ini = 3100.615 uV, v_off_fin = 3078.906 uV 18:12:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.549 uVs 18:12:30 Integrated Voltage Measurement... 18:12:39 Voltage Offset Correction: v_off_ini = 3079.340 uV, v_off_fin = 3093.321 uV 18:12:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.457 uVs 18:12:39 Integrated Voltage Measurement... 18:12:48 Voltage Offset Correction: v_off_ini = 3060.272 uV, v_off_fin = 3089.368 uV 18:12:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.834 uVs 18:12:48 Integrated Voltage Measurement... 18:12:57 Voltage Offset Correction: v_off_ini = 3090.732 uV, v_off_fin = 3099.294 uV 18:12:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.272 uVs 18:12:59 I2Y Average and RMS of Measurements VT = -321.904 +- 4.375 uVs I2Y = -29.615 +- 0.402 uTm^2 18:13:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:13:07 Integrated Voltage Measurement... 18:13:16 Voltage Offset Correction: v_off_ini = 3078.517 uV, v_off_fin = 3074.753 uV 18:13:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.944 uVs 18:13:16 Integrated Voltage Measurement... 18:13:25 Voltage Offset Correction: v_off_ini = 3078.159 uV, v_off_fin = 3100.690 uV 18:13:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.297 uVs 18:13:25 Integrated Voltage Measurement... 18:13:34 Voltage Offset Correction: v_off_ini = 3087.046 uV, v_off_fin = 3070.336 uV 18:13:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.107 uVs 18:13:34 Integrated Voltage Measurement... 18:13:43 Voltage Offset Correction: v_off_ini = 3091.699 uV, v_off_fin = 3068.200 uV 18:13:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.879 uVs 18:13:43 Integrated Voltage Measurement... 18:13:52 Voltage Offset Correction: v_off_ini = 3067.187 uV, v_off_fin = 3095.400 uV 18:13:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.411 uVs 18:13:52 Integrated Voltage Measurement... 18:14:01 Voltage Offset Correction: v_off_ini = 3116.947 uV, v_off_fin = 3099.118 uV 18:14:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.523 uVs 18:14:06 I1X Average and RMS of Measurements VT = -98.193 +- 10.800 uVs I1X = 19.639 +- 2.160 uTm 18:14:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:14:12 Integrated Voltage Measurement... 18:14:21 Voltage Offset Correction: v_off_ini = 3079.595 uV, v_off_fin = 3066.041 uV 18:14:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.338 uVs 18:14:21 Integrated Voltage Measurement... 18:14:30 Voltage Offset Correction: v_off_ini = 3082.569 uV, v_off_fin = 3066.392 uV 18:14:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.443 uVs 18:14:30 Integrated Voltage Measurement... 18:14:39 Voltage Offset Correction: v_off_ini = 3048.359 uV, v_off_fin = 3035.757 uV 18:14:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.270 uVs 18:14:39 Integrated Voltage Measurement... 18:14:48 Voltage Offset Correction: v_off_ini = 3106.993 uV, v_off_fin = 3082.658 uV 18:14:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.897 uVs 18:14:48 Integrated Voltage Measurement... 18:14:57 Voltage Offset Correction: v_off_ini = 3065.796 uV, v_off_fin = 3072.141 uV 18:14:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.682 uVs 18:14:57 Integrated Voltage Measurement... 18:15:06 Voltage Offset Correction: v_off_ini = 3074.832 uV, v_off_fin = 3064.933 uV 18:15:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.740 uVs 18:15:10 I1Y Average and RMS of Measurements VT = -202.228 +- 4.238 uVs I1Y = -40.445 +- 0.847 uTm 18:15:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:15:15 Integrated Voltage Measurement... 18:15:24 Voltage Offset Correction: v_off_ini = 3029.226 uV, v_off_fin = 3020.356 uV 18:15:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.242 uVs 18:15:24 Integrated Voltage Measurement... 18:15:33 Voltage Offset Correction: v_off_ini = 3085.717 uV, v_off_fin = 3115.879 uV 18:15:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.205 uVs 18:15:34 Integrated Voltage Measurement... 18:15:42 Voltage Offset Correction: v_off_ini = 3050.175 uV, v_off_fin = 3081.486 uV 18:15:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.726 uVs 18:15:43 Integrated Voltage Measurement... 18:15:51 Voltage Offset Correction: v_off_ini = 3066.916 uV, v_off_fin = 3069.604 uV 18:15:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.555 uVs 18:15:52 Integrated Voltage Measurement... 18:16:01 Voltage Offset Correction: v_off_ini = 3086.626 uV, v_off_fin = 3069.193 uV 18:16:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.703 uVs 18:16:01 Integrated Voltage Measurement... 18:16:10 Voltage Offset Correction: v_off_ini = 3061.584 uV, v_off_fin = 3086.351 uV 18:16:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.471 uVs 18:16:12 I2X Average and RMS of Measurements VT = -110.817 +- 20.197 uVs I2X = 10.195 +- 1.858 uTm^2 18:16:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:16:17 Integrated Voltage Measurement... 18:16:26 Voltage Offset Correction: v_off_ini = 3095.725 uV, v_off_fin = 3051.441 uV 18:16:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.917 uVs 18:16:26 Integrated Voltage Measurement... 18:16:35 Voltage Offset Correction: v_off_ini = 3088.754 uV, v_off_fin = 3083.272 uV 18:16:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.270 uVs 18:16:35 Integrated Voltage Measurement... 18:16:44 Voltage Offset Correction: v_off_ini = 3083.208 uV, v_off_fin = 3072.956 uV 18:16:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.494 uVs 18:16:44 Integrated Voltage Measurement... 18:16:53 Voltage Offset Correction: v_off_ini = 3053.275 uV, v_off_fin = 3065.701 uV 18:16:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.143 uVs 18:16:53 Integrated Voltage Measurement... 18:17:02 Voltage Offset Correction: v_off_ini = 3086.531 uV, v_off_fin = 3092.680 uV 18:17:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.805 uVs 18:17:02 Integrated Voltage Measurement... 18:17:11 Voltage Offset Correction: v_off_ini = 3095.721 uV, v_off_fin = 3076.163 uV 18:17:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.007 uVs 18:17:14 I2Y Average and RMS of Measurements VT = -315.939 +- 16.263 uVs I2Y = -29.066 +- 1.496 uTm^2 18:17:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:17:22 Integrated Voltage Measurement... 18:17:31 Voltage Offset Correction: v_off_ini = 3088.841 uV, v_off_fin = 3095.671 uV 18:17:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.290 uVs 18:17:31 Integrated Voltage Measurement... 18:17:40 Voltage Offset Correction: v_off_ini = 3062.003 uV, v_off_fin = 3078.236 uV 18:17:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.979 uVs 18:17:40 Integrated Voltage Measurement... 18:17:49 Voltage Offset Correction: v_off_ini = 3077.261 uV, v_off_fin = 3092.763 uV 18:17:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.157 uVs 18:17:49 Integrated Voltage Measurement... 18:17:58 Voltage Offset Correction: v_off_ini = 3098.269 uV, v_off_fin = 3105.664 uV 18:17:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.208 uVs 18:17:58 Integrated Voltage Measurement... 18:18:07 Voltage Offset Correction: v_off_ini = 3102.041 uV, v_off_fin = 3073.542 uV 18:18:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.858 uVs 18:18:07 Integrated Voltage Measurement... 18:18:16 Voltage Offset Correction: v_off_ini = 3108.157 uV, v_off_fin = 3090.387 uV 18:18:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.078 uVs 18:18:20 I1X Average and RMS of Measurements VT = -97.095 +- 3.845 uVs I1X = 19.419 +- 0.769 uTm 18:18:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:18:27 Integrated Voltage Measurement... 18:18:36 Voltage Offset Correction: v_off_ini = 3066.683 uV, v_off_fin = 3047.564 uV 18:18:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.158 uVs 18:18:36 Integrated Voltage Measurement... 18:18:45 Voltage Offset Correction: v_off_ini = 3072.968 uV, v_off_fin = 3095.385 uV 18:18:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.560 uVs 18:18:45 Integrated Voltage Measurement... 18:18:54 Voltage Offset Correction: v_off_ini = 3058.603 uV, v_off_fin = 3051.765 uV 18:18:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.734 uVs 18:18:54 Integrated Voltage Measurement... 18:19:03 Voltage Offset Correction: v_off_ini = 3088.750 uV, v_off_fin = 3093.488 uV 18:19:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.031 uVs 18:19:03 Integrated Voltage Measurement... 18:19:12 Voltage Offset Correction: v_off_ini = 3070.370 uV, v_off_fin = 3048.725 uV 18:19:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.718 uVs 18:19:12 Integrated Voltage Measurement... 18:19:21 Voltage Offset Correction: v_off_ini = 3065.305 uV, v_off_fin = 3086.120 uV 18:19:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.362 uVs 18:19:25 I1Y Average and RMS of Measurements VT = -199.427 +- 1.625 uVs I1Y = -39.882 +- 0.326 uTm 18:19:27 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:19:30 Integrated Voltage Measurement... 18:19:39 Voltage Offset Correction: v_off_ini = 3084.542 uV, v_off_fin = 3077.911 uV 18:19:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.422 uVs 18:19:39 Integrated Voltage Measurement... 18:19:48 Voltage Offset Correction: v_off_ini = 3104.868 uV, v_off_fin = 3080.681 uV 18:19:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.697 uVs 18:19:48 Integrated Voltage Measurement... 18:19:57 Voltage Offset Correction: v_off_ini = 3102.522 uV, v_off_fin = 3081.498 uV 18:19:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.787 uVs 18:19:57 Integrated Voltage Measurement... 18:20:06 Voltage Offset Correction: v_off_ini = 3097.800 uV, v_off_fin = 3106.180 uV 18:20:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.260 uVs 18:20:06 Integrated Voltage Measurement... 18:20:15 Voltage Offset Correction: v_off_ini = 3103.707 uV, v_off_fin = 3095.980 uV 18:20:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.870 uVs 18:20:15 Integrated Voltage Measurement... 18:20:24 Voltage Offset Correction: v_off_ini = 3085.185 uV, v_off_fin = 3114.890 uV 18:20:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.890 uVs 18:20:26 I2X Average and RMS of Measurements VT = -102.154 +- 8.733 uVs I2X = 9.398 +- 0.803 uTm^2 18:20:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:20:31 Integrated Voltage Measurement... 18:20:40 Voltage Offset Correction: v_off_ini = 3113.717 uV, v_off_fin = 3084.745 uV 18:20:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.401 uVs 18:20:40 Integrated Voltage Measurement... 18:20:49 Voltage Offset Correction: v_off_ini = 3088.634 uV, v_off_fin = 3109.134 uV 18:20:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.860 uVs 18:20:49 Integrated Voltage Measurement... 18:20:58 Voltage Offset Correction: v_off_ini = 3098.746 uV, v_off_fin = 3092.253 uV 18:20:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.164 uVs 18:20:58 Integrated Voltage Measurement... 18:21:07 Voltage Offset Correction: v_off_ini = 3109.257 uV, v_off_fin = 3115.359 uV 18:21:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.098 uVs 18:21:07 Integrated Voltage Measurement... 18:21:16 Voltage Offset Correction: v_off_ini = 3095.177 uV, v_off_fin = 3128.813 uV 18:21:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.163 uVs 18:21:17 Integrated Voltage Measurement... 18:21:26 Voltage Offset Correction: v_off_ini = 3134.730 uV, v_off_fin = 3142.686 uV 18:21:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 298.369 uVs 18:21:28 I2Y Average and RMS of Measurements VT = -306.009 +- 2.990 uVs I2Y = -28.153 +- 0.275 uTm^2 18:21:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:21:49 Integrated Voltage Measurement... 18:21:58 Voltage Offset Correction: v_off_ini = 3114.646 uV, v_off_fin = 3094.269 uV 18:21:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -117.820 uVs 18:21:58 Integrated Voltage Measurement... 18:22:07 Voltage Offset Correction: v_off_ini = 3121.460 uV, v_off_fin = 3111.114 uV 18:22:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.772 uVs 18:22:07 Integrated Voltage Measurement... 18:22:16 Voltage Offset Correction: v_off_ini = 3090.210 uV, v_off_fin = 3074.230 uV 18:22:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.436 uVs 18:22:16 Integrated Voltage Measurement... 18:22:25 Voltage Offset Correction: v_off_ini = 3098.616 uV, v_off_fin = 3118.635 uV 18:22:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.516 uVs 18:22:25 Integrated Voltage Measurement... 18:22:34 Voltage Offset Correction: v_off_ini = 3110.686 uV, v_off_fin = 3112.900 uV 18:22:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.598 uVs 18:22:34 Integrated Voltage Measurement... 18:22:43 Voltage Offset Correction: v_off_ini = 3125.766 uV, v_off_fin = 3109.056 uV 18:22:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.175 uVs 18:22:47 I1X Average and RMS of Measurements VT = -94.386 +- 8.215 uVs I1X = 18.879 +- 1.643 uTm 18:22:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:22:54 Integrated Voltage Measurement... 18:23:03 Voltage Offset Correction: v_off_ini = 3125.667 uV, v_off_fin = 3112.196 uV 18:23:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.370 uVs 18:23:03 Integrated Voltage Measurement... 18:23:12 Voltage Offset Correction: v_off_ini = 3093.411 uV, v_off_fin = 3080.198 uV 18:23:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.532 uVs 18:23:12 Integrated Voltage Measurement... 18:23:21 Voltage Offset Correction: v_off_ini = 3104.375 uV, v_off_fin = 3110.881 uV 18:23:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.999 uVs 18:23:21 Integrated Voltage Measurement... 18:23:30 Voltage Offset Correction: v_off_ini = 3125.597 uV, v_off_fin = 3123.978 uV 18:23:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.864 uVs 18:23:30 Integrated Voltage Measurement... 18:23:39 Voltage Offset Correction: v_off_ini = 3112.969 uV, v_off_fin = 3124.104 uV 18:23:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.295 uVs 18:23:39 Integrated Voltage Measurement... 18:23:48 Voltage Offset Correction: v_off_ini = 3065.272 uV, v_off_fin = 3097.651 uV 18:23:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.511 uVs 18:23:52 I1Y Average and RMS of Measurements VT = -189.929 +- 18.967 uVs I1Y = -37.986 +- 3.793 uTm 18:23:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:24:00 Integrated Voltage Measurement... 18:24:09 Voltage Offset Correction: v_off_ini = 3113.310 uV, v_off_fin = 3133.944 uV 18:24:09 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -79.421 uVs 18:24:09 Integrated Voltage Measurement... 18:24:18 Voltage Offset Correction: v_off_ini = 3083.877 uV, v_off_fin = 3109.474 uV 18:24:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.780 uVs 18:24:18 Integrated Voltage Measurement... 18:24:27 Voltage Offset Correction: v_off_ini = 3102.281 uV, v_off_fin = 3090.443 uV 18:24:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.973 uVs 18:24:27 Integrated Voltage Measurement... 18:24:36 Voltage Offset Correction: v_off_ini = 3107.236 uV, v_off_fin = 3101.135 uV 18:24:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.827 uVs 18:24:36 Integrated Voltage Measurement... 18:24:45 Voltage Offset Correction: v_off_ini = 3070.995 uV, v_off_fin = 3093.372 uV 18:24:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.771 uVs 18:24:45 Integrated Voltage Measurement... 18:24:54 Voltage Offset Correction: v_off_ini = 3106.641 uV, v_off_fin = 3119.224 uV 18:24:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.810 uVs 18:24:56 I2X Average and RMS of Measurements VT = -103.930 +- 10.970 uVs I2X = 9.561 +- 1.009 uTm^2 18:25:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:25:04 Integrated Voltage Measurement... 18:25:13 Voltage Offset Correction: v_off_ini = 3101.930 uV, v_off_fin = 3115.919 uV 18:25:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.148 uVs 18:25:13 Integrated Voltage Measurement... 18:25:22 Voltage Offset Correction: v_off_ini = 3104.442 uV, v_off_fin = 3102.937 uV 18:25:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.931 uVs 18:25:22 Integrated Voltage Measurement... 18:25:31 Voltage Offset Correction: v_off_ini = 3108.685 uV, v_off_fin = 3107.262 uV 18:25:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.550 uVs 18:25:31 Integrated Voltage Measurement... 18:25:40 Voltage Offset Correction: v_off_ini = 3109.791 uV, v_off_fin = 3096.795 uV 18:25:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.017 uVs 18:25:40 Integrated Voltage Measurement... 18:25:49 Voltage Offset Correction: v_off_ini = 3097.761 uV, v_off_fin = 3091.330 uV 18:25:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.259 uVs 18:25:49 Integrated Voltage Measurement... 18:25:58 Voltage Offset Correction: v_off_ini = 3119.651 uV, v_off_fin = 3117.403 uV 18:25:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.552 uVs 18:26:00 I2Y Average and RMS of Measurements VT = -300.409 +- 9.587 uVs I2Y = -27.638 +- 0.882 uTm^2 18:26:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:26:09 Integrated Voltage Measurement... 18:26:18 Voltage Offset Correction: v_off_ini = 3140.112 uV, v_off_fin = 3173.833 uV 18:26:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.463 uVs 18:26:18 Integrated Voltage Measurement... 18:26:27 Voltage Offset Correction: v_off_ini = 3127.642 uV, v_off_fin = 3155.501 uV 18:26:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.510 uVs 18:26:27 Integrated Voltage Measurement... 18:26:36 Voltage Offset Correction: v_off_ini = 3155.822 uV, v_off_fin = 3142.702 uV 18:26:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.941 uVs 18:26:36 Integrated Voltage Measurement... 18:26:45 Voltage Offset Correction: v_off_ini = 3137.246 uV, v_off_fin = 3154.250 uV 18:26:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.604 uVs 18:26:45 Integrated Voltage Measurement... 18:26:54 Voltage Offset Correction: v_off_ini = 3090.690 uV, v_off_fin = 3137.210 uV 18:26:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.401 uVs 18:26:54 Integrated Voltage Measurement... 18:27:03 Voltage Offset Correction: v_off_ini = 3158.630 uV, v_off_fin = 3152.651 uV 18:27:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 103.671 uVs 18:27:07 I1X Average and RMS of Measurements VT = -111.932 +- 7.870 uVs I1X = 22.387 +- 1.574 uTm 18:27:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:27:14 Integrated Voltage Measurement... 18:27:23 Voltage Offset Correction: v_off_ini = 3118.637 uV, v_off_fin = 3120.341 uV 18:27:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.029 uVs 18:27:23 Integrated Voltage Measurement... 18:27:32 Voltage Offset Correction: v_off_ini = 3110.607 uV, v_off_fin = 3144.966 uV 18:27:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.586 uVs 18:27:32 Integrated Voltage Measurement... 18:27:41 Voltage Offset Correction: v_off_ini = 3140.988 uV, v_off_fin = 3124.991 uV 18:27:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -148.661 uVs 18:27:41 Integrated Voltage Measurement... 18:27:50 Voltage Offset Correction: v_off_ini = 3128.123 uV, v_off_fin = 3132.124 uV 18:27:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.535 uVs 18:27:50 Integrated Voltage Measurement... 18:27:59 Voltage Offset Correction: v_off_ini = 3130.316 uV, v_off_fin = 3180.945 uV 18:27:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.917 uVs 18:27:59 Integrated Voltage Measurement... 18:28:08 Voltage Offset Correction: v_off_ini = 3162.231 uV, v_off_fin = 3147.660 uV 18:28:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.450 uVs 18:28:12 I1Y Average and RMS of Measurements VT = -193.196 +- 12.287 uVs I1Y = -38.639 +- 2.457 uTm 18:28:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:28:20 Integrated Voltage Measurement... 18:28:29 Voltage Offset Correction: v_off_ini = 3149.228 uV, v_off_fin = 3145.758 uV 18:28:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.340 uVs 18:28:29 Integrated Voltage Measurement... 18:28:38 Voltage Offset Correction: v_off_ini = 3161.468 uV, v_off_fin = 3148.533 uV 18:28:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.834 uVs 18:28:38 Integrated Voltage Measurement... 18:28:47 Voltage Offset Correction: v_off_ini = 3128.941 uV, v_off_fin = 3118.552 uV 18:28:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.617 uVs 18:28:47 Integrated Voltage Measurement... 18:28:56 Voltage Offset Correction: v_off_ini = 3185.268 uV, v_off_fin = 3157.925 uV 18:28:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.879 uVs 18:28:56 Integrated Voltage Measurement... 18:29:05 Voltage Offset Correction: v_off_ini = 3119.362 uV, v_off_fin = 3117.315 uV 18:29:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.498 uVs 18:29:05 Integrated Voltage Measurement... 18:29:14 Voltage Offset Correction: v_off_ini = 3136.889 uV, v_off_fin = 3152.402 uV 18:29:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.313 uVs 18:29:16 I2X Average and RMS of Measurements VT = -90.247 +- 17.128 uVs I2X = 8.303 +- 1.576 uTm^2 18:29:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:29:24 Integrated Voltage Measurement... 18:29:33 Voltage Offset Correction: v_off_ini = 3088.708 uV, v_off_fin = 3112.806 uV 18:29:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.799 uVs 18:29:33 Integrated Voltage Measurement... 18:29:42 Voltage Offset Correction: v_off_ini = 3128.274 uV, v_off_fin = 3062.323 uV 18:29:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.866 uVs 18:29:42 Integrated Voltage Measurement... 18:29:51 Voltage Offset Correction: v_off_ini = 3144.362 uV, v_off_fin = 3110.872 uV 18:29:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.386 uVs 18:29:51 Integrated Voltage Measurement... 18:30:00 Voltage Offset Correction: v_off_ini = 3169.400 uV, v_off_fin = 3163.851 uV 18:30:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.224 uVs 18:30:00 Integrated Voltage Measurement... 18:30:09 Voltage Offset Correction: v_off_ini = 3124.848 uV, v_off_fin = 3117.811 uV 18:30:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.214 uVs 18:30:09 Integrated Voltage Measurement... 18:30:18 Voltage Offset Correction: v_off_ini = 3148.371 uV, v_off_fin = 3103.234 uV 18:30:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.796 uVs 18:30:21 I2Y Average and RMS of Measurements VT = -313.048 +- 0.892 uVs I2Y = -28.800 +- 0.082 uTm^2 18:30:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:30:29 Integrated Voltage Measurement... 18:30:38 Voltage Offset Correction: v_off_ini = 3151.643 uV, v_off_fin = 3127.821 uV 18:30:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.868 uVs 18:30:38 Integrated Voltage Measurement... 18:30:47 Voltage Offset Correction: v_off_ini = 3102.659 uV, v_off_fin = 3119.783 uV 18:30:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.688 uVs 18:30:47 Integrated Voltage Measurement... 18:30:56 Voltage Offset Correction: v_off_ini = 3127.221 uV, v_off_fin = 3141.902 uV 18:30:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.938 uVs 18:30:56 Integrated Voltage Measurement... 18:31:05 Voltage Offset Correction: v_off_ini = 3157.440 uV, v_off_fin = 3177.173 uV 18:31:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.764 uVs 18:31:05 Integrated Voltage Measurement... 18:31:14 Voltage Offset Correction: v_off_ini = 3120.371 uV, v_off_fin = 3144.002 uV 18:31:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.190 uVs 18:31:14 Integrated Voltage Measurement... 18:31:23 Voltage Offset Correction: v_off_ini = 3113.855 uV, v_off_fin = 3130.172 uV 18:31:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.227 uVs 18:31:28 I1X Average and RMS of Measurements VT = -108.113 +- 15.182 uVs I1X = 21.623 +- 3.036 uTm 18:31:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:31:34 Integrated Voltage Measurement... 18:31:43 Voltage Offset Correction: v_off_ini = 3133.395 uV, v_off_fin = 3146.688 uV 18:31:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.131 uVs 18:31:43 Integrated Voltage Measurement... 18:31:52 Voltage Offset Correction: v_off_ini = 3137.145 uV, v_off_fin = 3150.181 uV 18:31:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.448 uVs 18:31:52 Integrated Voltage Measurement... 18:32:01 Voltage Offset Correction: v_off_ini = 3136.683 uV, v_off_fin = 3122.526 uV 18:32:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.142 uVs 18:32:01 Integrated Voltage Measurement... 18:32:10 Voltage Offset Correction: v_off_ini = 3125.621 uV, v_off_fin = 3144.307 uV 18:32:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.157 uVs 18:32:10 Integrated Voltage Measurement... 18:32:19 Voltage Offset Correction: v_off_ini = 3154.161 uV, v_off_fin = 3136.694 uV 18:32:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.874 uVs 18:32:19 Integrated Voltage Measurement... 18:32:28 Voltage Offset Correction: v_off_ini = 3128.871 uV, v_off_fin = 3161.895 uV 18:32:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.741 uVs 18:32:32 I1Y Average and RMS of Measurements VT = -202.749 +- 3.800 uVs I1Y = -40.550 +- 0.760 uTm 18:32:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:32:40 Integrated Voltage Measurement... 18:32:49 Voltage Offset Correction: v_off_ini = 3127.466 uV, v_off_fin = 3151.455 uV 18:32:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.067 uVs 18:32:49 Integrated Voltage Measurement... 18:32:58 Voltage Offset Correction: v_off_ini = 3141.310 uV, v_off_fin = 3161.642 uV 18:32:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.569 uVs 18:32:58 Integrated Voltage Measurement... 18:33:07 Voltage Offset Correction: v_off_ini = 3125.876 uV, v_off_fin = 3143.893 uV 18:33:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.014 uVs 18:33:07 Integrated Voltage Measurement... 18:33:16 Voltage Offset Correction: v_off_ini = 3141.222 uV, v_off_fin = 3126.739 uV 18:33:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.045 uVs 18:33:16 Integrated Voltage Measurement... 18:33:25 Voltage Offset Correction: v_off_ini = 3113.705 uV, v_off_fin = 3079.274 uV 18:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.149 uVs 18:33:25 Integrated Voltage Measurement... 18:33:34 Voltage Offset Correction: v_off_ini = 3100.276 uV, v_off_fin = 3079.042 uV 18:33:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.764 uVs 18:33:37 I2X Average and RMS of Measurements VT = -101.768 +- 12.802 uVs I2X = 9.363 +- 1.178 uTm^2 18:33:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:33:44 Integrated Voltage Measurement... 18:33:53 Voltage Offset Correction: v_off_ini = 3101.472 uV, v_off_fin = 3097.085 uV 18:33:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.136 uVs 18:33:53 Integrated Voltage Measurement... 18:34:02 Voltage Offset Correction: v_off_ini = 3086.332 uV, v_off_fin = 3111.154 uV 18:34:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.262 uVs 18:34:02 Integrated Voltage Measurement... 18:34:11 Voltage Offset Correction: v_off_ini = 3071.206 uV, v_off_fin = 3087.275 uV 18:34:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.856 uVs 18:34:11 Integrated Voltage Measurement... 18:34:20 Voltage Offset Correction: v_off_ini = 3067.489 uV, v_off_fin = 3081.169 uV 18:34:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.655 uVs 18:34:20 Integrated Voltage Measurement... 18:34:29 Voltage Offset Correction: v_off_ini = 3092.830 uV, v_off_fin = 3094.411 uV 18:34:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.471 uVs 18:34:29 Integrated Voltage Measurement... 18:34:38 Voltage Offset Correction: v_off_ini = 3092.033 uV, v_off_fin = 3091.403 uV 18:34:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.783 uVs 18:34:41 I2Y Average and RMS of Measurements VT = -301.527 +- 17.867 uVs I2Y = -27.741 +- 1.644 uTm^2 18:34:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:34:50 Integrated Voltage Measurement... 18:34:59 Voltage Offset Correction: v_off_ini = 3050.971 uV, v_off_fin = 3045.143 uV 18:34:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.359 uVs 18:34:59 Integrated Voltage Measurement... 18:35:08 Voltage Offset Correction: v_off_ini = 3050.148 uV, v_off_fin = 3062.428 uV 18:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.905 uVs 18:35:08 Integrated Voltage Measurement... 18:35:17 Voltage Offset Correction: v_off_ini = 3048.000 uV, v_off_fin = 3049.626 uV 18:35:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.362 uVs 18:35:17 Integrated Voltage Measurement... 18:35:26 Voltage Offset Correction: v_off_ini = 3081.918 uV, v_off_fin = 3103.618 uV 18:35:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.783 uVs 18:35:26 Integrated Voltage Measurement... 18:35:35 Voltage Offset Correction: v_off_ini = 3089.204 uV, v_off_fin = 3046.894 uV 18:35:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.354 uVs 18:35:35 Integrated Voltage Measurement... 18:35:43 Voltage Offset Correction: v_off_ini = 3048.227 uV, v_off_fin = 3039.698 uV 18:35:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.308 uVs 18:35:48 I1X Average and RMS of Measurements VT = -114.179 +- 5.192 uVs I1X = 22.836 +- 1.038 uTm 18:35:50 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:35:54 Integrated Voltage Measurement... 18:36:03 Voltage Offset Correction: v_off_ini = 3042.458 uV, v_off_fin = 3043.982 uV 18:36:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -203.880 uVs 18:36:03 Integrated Voltage Measurement... 18:36:12 Voltage Offset Correction: v_off_ini = 3074.386 uV, v_off_fin = 3072.634 uV 18:36:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.365 uVs 18:36:12 Integrated Voltage Measurement... 18:36:21 Voltage Offset Correction: v_off_ini = 3053.257 uV, v_off_fin = 3053.482 uV 18:36:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.375 uVs 18:36:21 Integrated Voltage Measurement... 18:36:30 Voltage Offset Correction: v_off_ini = 3059.791 uV, v_off_fin = 3099.548 uV 18:36:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.909 uVs 18:36:30 Integrated Voltage Measurement... 18:36:39 Voltage Offset Correction: v_off_ini = 3070.310 uV, v_off_fin = 3071.159 uV 18:36:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.811 uVs 18:36:39 Integrated Voltage Measurement... 18:36:48 Voltage Offset Correction: v_off_ini = 3062.134 uV, v_off_fin = 3104.028 uV 18:36:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.855 uVs 18:36:52 I1Y Average and RMS of Measurements VT = -202.699 +- 5.147 uVs I1Y = -40.540 +- 1.029 uTm 18:36:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:37:00 Integrated Voltage Measurement... 18:37:09 Voltage Offset Correction: v_off_ini = 3115.583 uV, v_off_fin = 3104.816 uV 18:37:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.855 uVs 18:37:09 Integrated Voltage Measurement... 18:37:18 Voltage Offset Correction: v_off_ini = 3104.293 uV, v_off_fin = 3081.914 uV 18:37:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 146.506 uVs 18:37:18 Integrated Voltage Measurement... 18:37:27 Voltage Offset Correction: v_off_ini = 3064.081 uV, v_off_fin = 3048.212 uV 18:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.621 uVs 18:37:27 Integrated Voltage Measurement... 18:37:36 Voltage Offset Correction: v_off_ini = 3106.105 uV, v_off_fin = 3127.263 uV 18:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.825 uVs 18:37:36 Integrated Voltage Measurement... 18:37:45 Voltage Offset Correction: v_off_ini = 3103.427 uV, v_off_fin = 3091.966 uV 18:37:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.992 uVs 18:37:45 Integrated Voltage Measurement... 18:37:54 Voltage Offset Correction: v_off_ini = 3109.558 uV, v_off_fin = 3085.322 uV 18:37:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.148 uVs 18:37:57 I2X Average and RMS of Measurements VT = -109.991 +- 21.068 uVs I2X = 10.119 +- 1.939 uTm^2 18:38:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:38:04 Integrated Voltage Measurement... 18:38:13 Voltage Offset Correction: v_off_ini = 3077.447 uV, v_off_fin = 3076.900 uV 18:38:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.411 uVs 18:38:13 Integrated Voltage Measurement... 18:38:22 Voltage Offset Correction: v_off_ini = 3068.809 uV, v_off_fin = 3070.259 uV 18:38:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.240 uVs 18:38:22 Integrated Voltage Measurement... 18:38:31 Voltage Offset Correction: v_off_ini = 3084.483 uV, v_off_fin = 3043.824 uV 18:38:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.209 uVs 18:38:31 Integrated Voltage Measurement... 18:38:40 Voltage Offset Correction: v_off_ini = 3089.682 uV, v_off_fin = 3072.104 uV 18:38:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.550 uVs 18:38:40 Integrated Voltage Measurement... 18:38:49 Voltage Offset Correction: v_off_ini = 3083.024 uV, v_off_fin = 3098.713 uV 18:38:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.800 uVs 18:38:49 Integrated Voltage Measurement... 18:38:58 Voltage Offset Correction: v_off_ini = 3107.228 uV, v_off_fin = 3104.159 uV 18:38:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.813 uVs 18:39:01 I2Y Average and RMS of Measurements VT = -290.004 +- 8.243 uVs I2Y = -26.680 +- 0.758 uTm^2 18:39:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:39:10 Integrated Voltage Measurement... 18:39:19 Voltage Offset Correction: v_off_ini = 3094.950 uV, v_off_fin = 3082.411 uV 18:39:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -81.598 uVs 18:39:19 Integrated Voltage Measurement... 18:39:28 Voltage Offset Correction: v_off_ini = 3109.868 uV, v_off_fin = 3083.548 uV 18:39:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.747 uVs 18:39:28 Integrated Voltage Measurement... 18:39:37 Voltage Offset Correction: v_off_ini = 3063.739 uV, v_off_fin = 3044.480 uV 18:39:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.074 uVs 18:39:37 Integrated Voltage Measurement... 18:39:46 Voltage Offset Correction: v_off_ini = 3043.791 uV, v_off_fin = 3039.803 uV 18:39:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.878 uVs 18:39:46 Integrated Voltage Measurement... 18:39:55 Voltage Offset Correction: v_off_ini = 3009.756 uV, v_off_fin = 3039.366 uV 18:39:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.164 uVs 18:39:55 Integrated Voltage Measurement... 18:40:04 Voltage Offset Correction: v_off_ini = 3027.266 uV, v_off_fin = 3039.714 uV 18:40:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.139 uVs 18:40:08 I1X Average and RMS of Measurements VT = -86.433 +- 9.793 uVs I1X = 17.288 +- 1.958 uTm 18:40:10 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:40:15 Integrated Voltage Measurement... 18:40:24 Voltage Offset Correction: v_off_ini = 3054.999 uV, v_off_fin = 3021.887 uV 18:40:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.632 uVs 18:40:24 Integrated Voltage Measurement... 18:40:33 Voltage Offset Correction: v_off_ini = 3038.320 uV, v_off_fin = 3049.380 uV 18:40:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.487 uVs 18:40:33 Integrated Voltage Measurement... 18:40:42 Voltage Offset Correction: v_off_ini = 3055.251 uV, v_off_fin = 3049.199 uV 18:40:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.491 uVs 18:40:42 Integrated Voltage Measurement... 18:40:51 Voltage Offset Correction: v_off_ini = 3080.030 uV, v_off_fin = 3058.899 uV 18:40:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.263 uVs 18:40:51 Integrated Voltage Measurement... 18:41:00 Voltage Offset Correction: v_off_ini = 3014.129 uV, v_off_fin = 3053.191 uV 18:41:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.530 uVs 18:41:00 Integrated Voltage Measurement... 18:41:09 Voltage Offset Correction: v_off_ini = 3059.292 uV, v_off_fin = 3049.525 uV 18:41:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.101 uVs 18:41:13 I1Y Average and RMS of Measurements VT = -199.251 +- 9.327 uVs I1Y = -39.850 +- 1.865 uTm 18:41:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:41:20 Integrated Voltage Measurement... 18:41:29 Voltage Offset Correction: v_off_ini = 3045.515 uV, v_off_fin = 3035.709 uV 18:41:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.395 uVs 18:41:30 Integrated Voltage Measurement... 18:41:39 Voltage Offset Correction: v_off_ini = 3025.895 uV, v_off_fin = 3057.568 uV 18:41:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.335 uVs 18:41:39 Integrated Voltage Measurement... 18:41:48 Voltage Offset Correction: v_off_ini = 3021.311 uV, v_off_fin = 3024.962 uV 18:41:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.446 uVs 18:41:48 Integrated Voltage Measurement... 18:41:57 Voltage Offset Correction: v_off_ini = 3060.082 uV, v_off_fin = 3033.086 uV 18:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.970 uVs 18:41:57 Integrated Voltage Measurement... 18:42:06 Voltage Offset Correction: v_off_ini = 3040.353 uV, v_off_fin = 3028.531 uV 18:42:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.997 uVs 18:42:06 Integrated Voltage Measurement... 18:42:15 Voltage Offset Correction: v_off_ini = 3060.005 uV, v_off_fin = 3040.650 uV 18:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.177 uVs 18:42:17 I2X Average and RMS of Measurements VT = -114.220 +- 13.349 uVs I2X = 10.508 +- 1.228 uTm^2 18:42:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:42:25 Integrated Voltage Measurement... 18:42:34 Voltage Offset Correction: v_off_ini = 3065.101 uV, v_off_fin = 3050.781 uV 18:42:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.045 uVs 18:42:34 Integrated Voltage Measurement... 18:42:43 Voltage Offset Correction: v_off_ini = 3061.983 uV, v_off_fin = 3063.050 uV 18:42:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.809 uVs 18:42:43 Integrated Voltage Measurement... 18:42:52 Voltage Offset Correction: v_off_ini = 3075.153 uV, v_off_fin = 3058.529 uV 18:42:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.257 uVs 18:42:52 Integrated Voltage Measurement... 18:43:01 Voltage Offset Correction: v_off_ini = 3055.657 uV, v_off_fin = 3079.565 uV 18:43:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.460 uVs 18:43:01 Integrated Voltage Measurement... 18:43:10 Voltage Offset Correction: v_off_ini = 3063.372 uV, v_off_fin = 3046.540 uV 18:43:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.817 uVs 18:43:10 Integrated Voltage Measurement... 18:43:19 Voltage Offset Correction: v_off_ini = 3028.294 uV, v_off_fin = 3042.752 uV 18:43:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.162 uVs 18:43:21 I2Y Average and RMS of Measurements VT = -322.758 +- 4.178 uVs I2Y = -29.694 +- 0.384 uTm^2 18:43:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:43:33 Integrated Voltage Measurement... 18:43:42 Voltage Offset Correction: v_off_ini = 3063.299 uV, v_off_fin = 3044.951 uV 18:43:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -120.915 uVs 18:43:42 Integrated Voltage Measurement... 18:43:51 Voltage Offset Correction: v_off_ini = 3058.647 uV, v_off_fin = 3078.459 uV 18:43:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.174 uVs 18:43:51 Integrated Voltage Measurement... 18:44:00 Voltage Offset Correction: v_off_ini = 3045.553 uV, v_off_fin = 3093.682 uV 18:44:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.247 uVs 18:44:00 Integrated Voltage Measurement... 18:44:09 Voltage Offset Correction: v_off_ini = 3076.717 uV, v_off_fin = 3081.963 uV 18:44:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.100 uVs 18:44:09 Integrated Voltage Measurement... 18:44:18 Voltage Offset Correction: v_off_ini = 3109.954 uV, v_off_fin = 3087.648 uV 18:44:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.416 uVs 18:44:18 Integrated Voltage Measurement... 18:44:27 Voltage Offset Correction: v_off_ini = 3081.597 uV, v_off_fin = 3087.513 uV 18:44:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.987 uVs 18:44:32 I1X Average and RMS of Measurements VT = -86.473 +- 11.022 uVs I1X = 17.295 +- 2.205 uTm 18:44:34 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:44:38 Integrated Voltage Measurement... 18:44:47 Voltage Offset Correction: v_off_ini = 3081.770 uV, v_off_fin = 3052.077 uV 18:44:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.982 uVs 18:44:47 Integrated Voltage Measurement... 18:44:56 Voltage Offset Correction: v_off_ini = 3065.769 uV, v_off_fin = 3077.184 uV 18:44:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.322 uVs 18:44:56 Integrated Voltage Measurement... 18:45:05 Voltage Offset Correction: v_off_ini = 3068.414 uV, v_off_fin = 3066.520 uV 18:45:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.857 uVs 18:45:05 Integrated Voltage Measurement... 18:45:14 Voltage Offset Correction: v_off_ini = 3071.837 uV, v_off_fin = 3071.655 uV 18:45:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.111 uVs 18:45:14 Integrated Voltage Measurement... 18:45:23 Voltage Offset Correction: v_off_ini = 3093.096 uV, v_off_fin = 3064.916 uV 18:45:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.987 uVs 18:45:23 Integrated Voltage Measurement... 18:45:32 Voltage Offset Correction: v_off_ini = 3061.604 uV, v_off_fin = 3097.284 uV 18:45:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.548 uVs 18:45:36 I1Y Average and RMS of Measurements VT = -203.634 +- 11.854 uVs I1Y = -40.727 +- 2.371 uTm 18:45:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:45:42 Integrated Voltage Measurement... 18:45:51 Voltage Offset Correction: v_off_ini = 3068.449 uV, v_off_fin = 3086.617 uV 18:45:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.408 uVs 18:45:51 Integrated Voltage Measurement... 18:46:00 Voltage Offset Correction: v_off_ini = 3115.484 uV, v_off_fin = 3129.641 uV 18:46:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.778 uVs 18:46:00 Integrated Voltage Measurement... 18:46:09 Voltage Offset Correction: v_off_ini = 3135.099 uV, v_off_fin = 3087.040 uV 18:46:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -161.302 uVs 18:46:09 Integrated Voltage Measurement... 18:46:18 Voltage Offset Correction: v_off_ini = 3103.260 uV, v_off_fin = 3095.566 uV 18:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.476 uVs 18:46:18 Integrated Voltage Measurement... 18:46:27 Voltage Offset Correction: v_off_ini = 3094.276 uV, v_off_fin = 3084.580 uV 18:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.183 uVs 18:46:27 Integrated Voltage Measurement... 18:46:36 Voltage Offset Correction: v_off_ini = 3131.591 uV, v_off_fin = 3122.302 uV 18:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.027 uVs 18:46:38 I2X Average and RMS of Measurements VT = -106.696 +- 21.933 uVs I2X = 9.816 +- 2.018 uTm^2 18:46:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:46:43 Integrated Voltage Measurement... 18:46:52 Voltage Offset Correction: v_off_ini = 3114.550 uV, v_off_fin = 3061.211 uV 18:46:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.164 uVs 18:46:52 Integrated Voltage Measurement... 18:47:01 Voltage Offset Correction: v_off_ini = 3098.994 uV, v_off_fin = 3106.493 uV 18:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.210 uVs 18:47:01 Integrated Voltage Measurement... 18:47:10 Voltage Offset Correction: v_off_ini = 3056.388 uV, v_off_fin = 3075.625 uV 18:47:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.995 uVs 18:47:10 Integrated Voltage Measurement... 18:47:19 Voltage Offset Correction: v_off_ini = 3133.953 uV, v_off_fin = 3104.704 uV 18:47:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.722 uVs 18:47:19 Integrated Voltage Measurement... 18:47:28 Voltage Offset Correction: v_off_ini = 3103.951 uV, v_off_fin = 3114.614 uV 18:47:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.447 uVs 18:47:28 Integrated Voltage Measurement... 18:47:37 Voltage Offset Correction: v_off_ini = 3127.820 uV, v_off_fin = 3123.900 uV 18:47:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.769 uVs 18:47:40 I2Y Average and RMS of Measurements VT = -293.051 +- 7.893 uVs I2Y = -26.961 +- 0.726 uTm^2 18:47:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:47:48 Integrated Voltage Measurement... 18:47:57 Voltage Offset Correction: v_off_ini = 3122.451 uV, v_off_fin = 3108.494 uV 18:47:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -142.095 uVs 18:47:57 Integrated Voltage Measurement... 18:48:06 Voltage Offset Correction: v_off_ini = 3109.427 uV, v_off_fin = 3127.704 uV 18:48:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.800 uVs 18:48:06 Integrated Voltage Measurement... 18:48:15 Voltage Offset Correction: v_off_ini = 3100.233 uV, v_off_fin = 3130.263 uV 18:48:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.315 uVs 18:48:15 Integrated Voltage Measurement... 18:48:24 Voltage Offset Correction: v_off_ini = 3125.665 uV, v_off_fin = 3113.993 uV 18:48:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.867 uVs 18:48:24 Integrated Voltage Measurement... 18:48:33 Voltage Offset Correction: v_off_ini = 3094.967 uV, v_off_fin = 3105.136 uV 18:48:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.181 uVs 18:48:33 Integrated Voltage Measurement... 18:48:42 Voltage Offset Correction: v_off_ini = 3086.177 uV, v_off_fin = 3129.781 uV 18:48:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 124.506 uVs 18:48:46 I1X Average and RMS of Measurements VT = -108.961 +- 15.527 uVs I1X = 21.794 +- 3.106 uTm 18:48:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:48:53 Integrated Voltage Measurement... 18:49:02 Voltage Offset Correction: v_off_ini = 3114.631 uV, v_off_fin = 3134.324 uV 18:49:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.375 uVs 18:49:02 Integrated Voltage Measurement... 18:49:11 Voltage Offset Correction: v_off_ini = 3139.181 uV, v_off_fin = 3146.965 uV 18:49:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.514 uVs 18:49:11 Integrated Voltage Measurement... 18:49:20 Voltage Offset Correction: v_off_ini = 3118.696 uV, v_off_fin = 3117.129 uV 18:49:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.588 uVs 18:49:20 Integrated Voltage Measurement... 18:49:29 Voltage Offset Correction: v_off_ini = 3127.637 uV, v_off_fin = 3129.294 uV 18:49:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.897 uVs 18:49:29 Integrated Voltage Measurement... 18:49:38 Voltage Offset Correction: v_off_ini = 3112.823 uV, v_off_fin = 3128.099 uV 18:49:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.541 uVs 18:49:38 Integrated Voltage Measurement... 18:49:47 Voltage Offset Correction: v_off_ini = 3125.635 uV, v_off_fin = 3133.678 uV 18:49:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.156 uVs 18:49:51 I1Y Average and RMS of Measurements VT = -207.679 +- 7.795 uVs I1Y = -41.536 +- 1.559 uTm 18:49:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:49:56 Integrated Voltage Measurement... 18:50:05 Voltage Offset Correction: v_off_ini = 3079.332 uV, v_off_fin = 3084.470 uV 18:50:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -157.494 uVs 18:50:05 Integrated Voltage Measurement... 18:50:14 Voltage Offset Correction: v_off_ini = 3112.664 uV, v_off_fin = 3085.682 uV 18:50:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.942 uVs 18:50:15 Integrated Voltage Measurement... 18:50:24 Voltage Offset Correction: v_off_ini = 3115.797 uV, v_off_fin = 3093.992 uV 18:50:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.344 uVs 18:50:24 Integrated Voltage Measurement... 18:50:33 Voltage Offset Correction: v_off_ini = 3086.227 uV, v_off_fin = 3076.955 uV 18:50:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.424 uVs 18:50:33 Integrated Voltage Measurement... 18:50:42 Voltage Offset Correction: v_off_ini = 3085.948 uV, v_off_fin = 3075.450 uV 18:50:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -131.583 uVs 18:50:42 Integrated Voltage Measurement... 18:50:51 Voltage Offset Correction: v_off_ini = 3074.360 uV, v_off_fin = 3101.079 uV 18:50:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.781 uVs 18:50:53 I2X Average and RMS of Measurements VT = -121.595 +- 18.636 uVs I2X = 11.187 +- 1.715 uTm^2 18:50:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:50:58 Integrated Voltage Measurement... 18:51:07 Voltage Offset Correction: v_off_ini = 3070.777 uV, v_off_fin = 3071.242 uV 18:51:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.117 uVs 18:51:07 Integrated Voltage Measurement... 18:51:16 Voltage Offset Correction: v_off_ini = 3085.808 uV, v_off_fin = 3077.101 uV 18:51:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.906 uVs 18:51:16 Integrated Voltage Measurement... 18:51:25 Voltage Offset Correction: v_off_ini = 3088.657 uV, v_off_fin = 3082.127 uV 18:51:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.544 uVs 18:51:25 Integrated Voltage Measurement... 18:51:34 Voltage Offset Correction: v_off_ini = 3075.210 uV, v_off_fin = 3100.743 uV 18:51:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.307 uVs 18:51:34 Integrated Voltage Measurement... 18:51:43 Voltage Offset Correction: v_off_ini = 3095.944 uV, v_off_fin = 3071.390 uV 18:51:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.110 uVs 18:51:43 Integrated Voltage Measurement... 18:51:52 Voltage Offset Correction: v_off_ini = 3082.852 uV, v_off_fin = 3078.285 uV 18:51:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.467 uVs 18:51:55 I2Y Average and RMS of Measurements VT = -316.242 +- 4.174 uVs I2Y = -29.094 +- 0.384 uTm^2 18:51:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:52:03 Integrated Voltage Measurement... 18:52:12 Voltage Offset Correction: v_off_ini = 3063.851 uV, v_off_fin = 3071.686 uV 18:52:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.197 uVs 18:52:12 Integrated Voltage Measurement... 18:52:21 Voltage Offset Correction: v_off_ini = 3083.491 uV, v_off_fin = 3078.212 uV 18:52:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.408 uVs 18:52:21 Integrated Voltage Measurement... 18:52:30 Voltage Offset Correction: v_off_ini = 3069.626 uV, v_off_fin = 3091.061 uV 18:52:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -102.183 uVs 18:52:30 Integrated Voltage Measurement... 18:52:39 Voltage Offset Correction: v_off_ini = 3101.329 uV, v_off_fin = 3087.447 uV 18:52:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -31.363 uVs 18:52:39 Integrated Voltage Measurement... 18:52:48 Voltage Offset Correction: v_off_ini = 3095.560 uV, v_off_fin = 3080.727 uV 18:52:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.141 uVs 18:52:48 Integrated Voltage Measurement... 18:52:57 Voltage Offset Correction: v_off_ini = 3066.824 uV, v_off_fin = 3094.928 uV 18:52:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.518 uVs 18:53:01 I1X Average and RMS of Measurements VT = -74.681 +- 27.780 uVs I1X = 14.937 +- 5.555 uTm 18:53:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:53:08 Integrated Voltage Measurement... 18:53:17 Voltage Offset Correction: v_off_ini = 3077.380 uV, v_off_fin = 3068.486 uV 18:53:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.066 uVs 18:53:17 Integrated Voltage Measurement... 18:53:26 Voltage Offset Correction: v_off_ini = 3086.138 uV, v_off_fin = 3065.337 uV 18:53:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.766 uVs 18:53:26 Integrated Voltage Measurement... 18:53:35 Voltage Offset Correction: v_off_ini = 3090.137 uV, v_off_fin = 3092.113 uV 18:53:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.804 uVs 18:53:35 Integrated Voltage Measurement... 18:53:44 Voltage Offset Correction: v_off_ini = 3091.770 uV, v_off_fin = 3132.459 uV 18:53:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.370 uVs 18:53:44 Integrated Voltage Measurement... 18:53:53 Voltage Offset Correction: v_off_ini = 3122.832 uV, v_off_fin = 3095.810 uV 18:53:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.896 uVs 18:53:53 Integrated Voltage Measurement... 18:54:02 Voltage Offset Correction: v_off_ini = 3105.555 uV, v_off_fin = 3135.637 uV 18:54:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.387 uVs 18:54:06 I1Y Average and RMS of Measurements VT = -214.715 +- 6.272 uVs I1Y = -42.942 +- 1.254 uTm 18:54:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:54:11 Integrated Voltage Measurement... 18:54:20 Voltage Offset Correction: v_off_ini = 3167.185 uV, v_off_fin = 3135.844 uV 18:54:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.879 uVs 18:54:20 Integrated Voltage Measurement... 18:54:29 Voltage Offset Correction: v_off_ini = 3139.278 uV, v_off_fin = 3142.598 uV 18:54:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.024 uVs 18:54:29 Integrated Voltage Measurement... 18:54:38 Voltage Offset Correction: v_off_ini = 3125.225 uV, v_off_fin = 3103.457 uV 18:54:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.766 uVs 18:54:38 Integrated Voltage Measurement... 18:54:47 Voltage Offset Correction: v_off_ini = 3134.108 uV, v_off_fin = 3127.956 uV 18:54:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.464 uVs 18:54:48 Integrated Voltage Measurement... 18:54:56 Voltage Offset Correction: v_off_ini = 3135.103 uV, v_off_fin = 3131.995 uV 18:54:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.239 uVs 18:54:57 Integrated Voltage Measurement... 18:55:06 Voltage Offset Correction: v_off_ini = 3150.067 uV, v_off_fin = 3129.546 uV 18:55:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.713 uVs 18:55:08 I2X Average and RMS of Measurements VT = -115.347 +- 7.631 uVs I2X = 10.612 +- 0.702 uTm^2 18:55:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:55:13 Integrated Voltage Measurement... 18:55:22 Voltage Offset Correction: v_off_ini = 3113.969 uV, v_off_fin = 3123.615 uV 18:55:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.312 uVs 18:55:22 Integrated Voltage Measurement... 18:55:31 Voltage Offset Correction: v_off_ini = 3143.617 uV, v_off_fin = 3140.488 uV 18:55:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.100 uVs 18:55:31 Integrated Voltage Measurement... 18:55:40 Voltage Offset Correction: v_off_ini = 3159.103 uV, v_off_fin = 3151.602 uV 18:55:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.243 uVs 18:55:40 Integrated Voltage Measurement... 18:55:49 Voltage Offset Correction: v_off_ini = 3148.628 uV, v_off_fin = 3142.822 uV 18:55:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.922 uVs 18:55:49 Integrated Voltage Measurement... 18:55:58 Voltage Offset Correction: v_off_ini = 3084.705 uV, v_off_fin = 3129.164 uV 18:55:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.977 uVs 18:55:58 Integrated Voltage Measurement... 18:56:07 Voltage Offset Correction: v_off_ini = 3147.183 uV, v_off_fin = 3136.671 uV 18:56:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.425 uVs 18:56:10 I2Y Average and RMS of Measurements VT = -297.330 +- 17.640 uVs I2Y = -27.354 +- 1.623 uTm^2 18:56:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:56:18 Integrated Voltage Measurement... 18:56:27 Voltage Offset Correction: v_off_ini = 3174.122 uV, v_off_fin = 3131.114 uV 18:56:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -131.575 uVs 18:56:27 Integrated Voltage Measurement... 18:56:36 Voltage Offset Correction: v_off_ini = 3125.699 uV, v_off_fin = 3130.665 uV 18:56:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.151 uVs 18:56:36 Integrated Voltage Measurement... 18:56:45 Voltage Offset Correction: v_off_ini = 3134.805 uV, v_off_fin = 3119.864 uV 18:56:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.775 uVs 18:56:45 Integrated Voltage Measurement... 18:56:54 Voltage Offset Correction: v_off_ini = 3129.413 uV, v_off_fin = 3138.995 uV 18:56:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.409 uVs 18:56:54 Integrated Voltage Measurement... 18:57:03 Voltage Offset Correction: v_off_ini = 3124.772 uV, v_off_fin = 3109.576 uV 18:57:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.255 uVs 18:57:03 Integrated Voltage Measurement... 18:57:12 Voltage Offset Correction: v_off_ini = 3128.345 uV, v_off_fin = 3094.903 uV 18:57:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.305 uVs 18:57:16 I1X Average and RMS of Measurements VT = -99.079 +- 22.278 uVs I1X = 19.817 +- 4.457 uTm 18:57:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:57:23 Integrated Voltage Measurement... 18:57:32 Voltage Offset Correction: v_off_ini = 3124.516 uV, v_off_fin = 3097.910 uV 18:57:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.819 uVs 18:57:32 Integrated Voltage Measurement... 18:57:41 Voltage Offset Correction: v_off_ini = 3103.546 uV, v_off_fin = 3111.002 uV 18:57:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.690 uVs 18:57:41 Integrated Voltage Measurement... 18:57:50 Voltage Offset Correction: v_off_ini = 3093.858 uV, v_off_fin = 3101.698 uV 18:57:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.827 uVs 18:57:50 Integrated Voltage Measurement... 18:57:59 Voltage Offset Correction: v_off_ini = 3096.109 uV, v_off_fin = 3106.114 uV 18:57:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.597 uVs 18:57:59 Integrated Voltage Measurement... 18:58:08 Voltage Offset Correction: v_off_ini = 3136.926 uV, v_off_fin = 3100.229 uV 18:58:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.713 uVs 18:58:08 Integrated Voltage Measurement... 18:58:17 Voltage Offset Correction: v_off_ini = 3118.495 uV, v_off_fin = 3122.897 uV 18:58:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.188 uVs 18:58:21 I1Y Average and RMS of Measurements VT = -205.639 +- 7.845 uVs I1Y = -41.125 +- 1.567 uTm 18:58:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:58:26 Integrated Voltage Measurement... 18:58:35 Voltage Offset Correction: v_off_ini = 3064.833 uV, v_off_fin = 3083.374 uV 18:58:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.233 uVs 18:58:35 Integrated Voltage Measurement... 18:58:44 Voltage Offset Correction: v_off_ini = 3098.899 uV, v_off_fin = 3086.901 uV 18:58:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.644 uVs 18:58:44 Integrated Voltage Measurement... 18:58:53 Voltage Offset Correction: v_off_ini = 3106.305 uV, v_off_fin = 3116.665 uV 18:58:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.242 uVs 18:58:53 Integrated Voltage Measurement... 18:59:02 Voltage Offset Correction: v_off_ini = 3120.498 uV, v_off_fin = 3119.581 uV 18:59:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.472 uVs 18:59:02 Integrated Voltage Measurement... 18:59:11 Voltage Offset Correction: v_off_ini = 3141.159 uV, v_off_fin = 3119.042 uV 18:59:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.062 uVs 18:59:11 Integrated Voltage Measurement... 18:59:20 Voltage Offset Correction: v_off_ini = 3087.538 uV, v_off_fin = 3126.063 uV 18:59:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.083 uVs 18:59:23 I2X Average and RMS of Measurements VT = -101.956 +- 9.883 uVs I2X = 9.380 +- 0.909 uTm^2 18:59:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:59:28 Integrated Voltage Measurement... 18:59:37 Voltage Offset Correction: v_off_ini = 3118.791 uV, v_off_fin = 3099.809 uV 18:59:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.002 uVs 18:59:37 Integrated Voltage Measurement... 18:59:46 Voltage Offset Correction: v_off_ini = 3103.794 uV, v_off_fin = 3113.095 uV 18:59:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.313 uVs 18:59:46 Integrated Voltage Measurement... 18:59:55 Voltage Offset Correction: v_off_ini = 3123.778 uV, v_off_fin = 3125.891 uV 18:59:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.240 uVs 18:59:55 Integrated Voltage Measurement... 19:00:04 Voltage Offset Correction: v_off_ini = 3094.870 uV, v_off_fin = 3119.605 uV 19:00:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.878 uVs 19:00:04 Integrated Voltage Measurement... 19:00:13 Voltage Offset Correction: v_off_ini = 3120.262 uV, v_off_fin = 3110.409 uV 19:00:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.081 uVs 19:00:13 Integrated Voltage Measurement... 19:00:22 Voltage Offset Correction: v_off_ini = 3108.023 uV, v_off_fin = 3127.293 uV 19:00:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.569 uVs 19:00:24 I2Y Average and RMS of Measurements VT = -310.847 +- 7.119 uVs I2Y = -28.598 +- 0.655 uTm^2 19:00:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:00:33 Integrated Voltage Measurement... 19:00:42 Voltage Offset Correction: v_off_ini = 3121.778 uV, v_off_fin = 3128.023 uV 19:00:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.686 uVs 19:00:42 Integrated Voltage Measurement... 19:00:51 Voltage Offset Correction: v_off_ini = 3097.018 uV, v_off_fin = 3082.225 uV 19:00:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.558 uVs 19:00:51 Integrated Voltage Measurement... 19:01:00 Voltage Offset Correction: v_off_ini = 3104.084 uV, v_off_fin = 3097.327 uV 19:01:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.558 uVs 19:01:00 Integrated Voltage Measurement... 19:01:09 Voltage Offset Correction: v_off_ini = 3121.573 uV, v_off_fin = 3121.228 uV 19:01:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.940 uVs 19:01:09 Integrated Voltage Measurement... 19:01:18 Voltage Offset Correction: v_off_ini = 3081.707 uV, v_off_fin = 3078.964 uV 19:01:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.130 uVs 19:01:18 Integrated Voltage Measurement... 19:01:27 Voltage Offset Correction: v_off_ini = 3085.030 uV, v_off_fin = 3091.971 uV 19:01:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.078 uVs 19:01:31 I1X Average and RMS of Measurements VT = -102.825 +- 17.486 uVs I1X = 20.566 +- 3.497 uTm 19:01:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:01:38 Integrated Voltage Measurement... 19:01:47 Voltage Offset Correction: v_off_ini = 3121.540 uV, v_off_fin = 3109.602 uV 19:01:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.599 uVs 19:01:47 Integrated Voltage Measurement... 19:01:56 Voltage Offset Correction: v_off_ini = 3120.748 uV, v_off_fin = 3141.489 uV 19:01:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.410 uVs 19:01:56 Integrated Voltage Measurement... 19:02:05 Voltage Offset Correction: v_off_ini = 3126.477 uV, v_off_fin = 3105.591 uV 19:02:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.381 uVs 19:02:05 Integrated Voltage Measurement... 19:02:14 Voltage Offset Correction: v_off_ini = 3096.912 uV, v_off_fin = 3094.429 uV 19:02:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.795 uVs 19:02:14 Integrated Voltage Measurement... 19:02:23 Voltage Offset Correction: v_off_ini = 3118.801 uV, v_off_fin = 3096.944 uV 19:02:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -166.196 uVs 19:02:23 Integrated Voltage Measurement... 19:02:32 Voltage Offset Correction: v_off_ini = 3161.206 uV, v_off_fin = 3135.189 uV 19:02:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.840 uVs 19:02:36 I1Y Average and RMS of Measurements VT = -199.370 +- 14.526 uVs I1Y = -39.870 +- 2.905 uTm 19:02:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:02:41 Integrated Voltage Measurement... 19:02:50 Voltage Offset Correction: v_off_ini = 3119.564 uV, v_off_fin = 3111.543 uV 19:02:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.274 uVs 19:02:50 Integrated Voltage Measurement... 19:02:59 Voltage Offset Correction: v_off_ini = 3115.912 uV, v_off_fin = 3121.208 uV 19:02:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.041 uVs 19:02:59 Integrated Voltage Measurement... 19:03:08 Voltage Offset Correction: v_off_ini = 3122.915 uV, v_off_fin = 3126.596 uV 19:03:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.921 uVs 19:03:08 Integrated Voltage Measurement... 19:03:17 Voltage Offset Correction: v_off_ini = 3107.398 uV, v_off_fin = 3133.084 uV 19:03:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.041 uVs 19:03:17 Integrated Voltage Measurement... 19:03:26 Voltage Offset Correction: v_off_ini = 3126.813 uV, v_off_fin = 3120.024 uV 19:03:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.923 uVs 19:03:26 Integrated Voltage Measurement... 19:03:35 Voltage Offset Correction: v_off_ini = 3109.496 uV, v_off_fin = 3124.618 uV 19:03:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.529 uVs 19:03:38 I2X Average and RMS of Measurements VT = -87.621 +- 5.380 uVs I2X = 8.061 +- 0.495 uTm^2 19:03:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:03:43 Integrated Voltage Measurement... 19:03:52 Voltage Offset Correction: v_off_ini = 3101.182 uV, v_off_fin = 3118.224 uV 19:03:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.801 uVs 19:03:52 Integrated Voltage Measurement... 19:04:01 Voltage Offset Correction: v_off_ini = 3092.305 uV, v_off_fin = 3103.962 uV 19:04:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.812 uVs 19:04:01 Integrated Voltage Measurement... 19:04:10 Voltage Offset Correction: v_off_ini = 3079.570 uV, v_off_fin = 3087.270 uV 19:04:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.711 uVs 19:04:10 Integrated Voltage Measurement... 19:04:19 Voltage Offset Correction: v_off_ini = 3065.237 uV, v_off_fin = 3056.830 uV 19:04:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.105 uVs 19:04:19 Integrated Voltage Measurement... 19:04:28 Voltage Offset Correction: v_off_ini = 3026.995 uV, v_off_fin = 3038.773 uV 19:04:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.757 uVs 19:04:28 Integrated Voltage Measurement... 19:04:37 Voltage Offset Correction: v_off_ini = 3078.301 uV, v_off_fin = 3064.167 uV 19:04:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.110 uVs 19:04:39 I2Y Average and RMS of Measurements VT = -297.549 +- 4.786 uVs I2Y = -27.375 +- 0.440 uTm^2 19:04:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:05:01 Integrated Voltage Measurement... 19:05:10 Voltage Offset Correction: v_off_ini = 3055.370 uV, v_off_fin = 3071.114 uV 19:05:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.920 uVs 19:05:10 Integrated Voltage Measurement... 19:05:19 Voltage Offset Correction: v_off_ini = 3067.318 uV, v_off_fin = 3068.438 uV 19:05:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.164 uVs 19:05:19 Integrated Voltage Measurement... 19:05:28 Voltage Offset Correction: v_off_ini = 3055.879 uV, v_off_fin = 3058.840 uV 19:05:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.184 uVs 19:05:28 Integrated Voltage Measurement... 19:05:37 Voltage Offset Correction: v_off_ini = 3078.589 uV, v_off_fin = 3090.370 uV 19:05:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.657 uVs 19:05:37 Integrated Voltage Measurement... 19:05:46 Voltage Offset Correction: v_off_ini = 3072.611 uV, v_off_fin = 3060.052 uV 19:05:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.145 uVs 19:05:46 Integrated Voltage Measurement... 19:05:55 Voltage Offset Correction: v_off_ini = 3058.947 uV, v_off_fin = 3059.202 uV 19:05:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.335 uVs 19:05:59 I1X Average and RMS of Measurements VT = -101.734 +- 5.981 uVs I1X = 20.347 +- 1.196 uTm 19:06:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:06:06 Integrated Voltage Measurement... 19:06:15 Voltage Offset Correction: v_off_ini = 3109.018 uV, v_off_fin = 3115.875 uV 19:06:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -191.007 uVs 19:06:15 Integrated Voltage Measurement... 19:06:24 Voltage Offset Correction: v_off_ini = 3106.272 uV, v_off_fin = 3117.831 uV 19:06:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.293 uVs 19:06:24 Integrated Voltage Measurement... 19:06:33 Voltage Offset Correction: v_off_ini = 3109.039 uV, v_off_fin = 3105.418 uV 19:06:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.078 uVs 19:06:33 Integrated Voltage Measurement... 19:06:42 Voltage Offset Correction: v_off_ini = 3114.128 uV, v_off_fin = 3121.781 uV 19:06:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.733 uVs 19:06:42 Integrated Voltage Measurement... 19:06:51 Voltage Offset Correction: v_off_ini = 3116.207 uV, v_off_fin = 3102.167 uV 19:06:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.751 uVs 19:06:51 Integrated Voltage Measurement... 19:07:00 Voltage Offset Correction: v_off_ini = 3107.816 uV, v_off_fin = 3124.531 uV 19:07:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.402 uVs 19:07:04 I1Y Average and RMS of Measurements VT = -180.710 +- 4.292 uVs I1Y = -36.143 +- 0.859 uTm 19:07:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:07:12 Integrated Voltage Measurement... 19:07:21 Voltage Offset Correction: v_off_ini = 3127.567 uV, v_off_fin = 3108.818 uV 19:07:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.756 uVs 19:07:21 Integrated Voltage Measurement... 19:07:30 Voltage Offset Correction: v_off_ini = 3110.178 uV, v_off_fin = 3125.829 uV 19:07:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.970 uVs 19:07:30 Integrated Voltage Measurement... 19:07:39 Voltage Offset Correction: v_off_ini = 3128.030 uV, v_off_fin = 3118.634 uV 19:07:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.882 uVs 19:07:39 Integrated Voltage Measurement... 19:07:48 Voltage Offset Correction: v_off_ini = 3078.722 uV, v_off_fin = 3154.318 uV 19:07:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.963 uVs 19:07:48 Integrated Voltage Measurement... 19:07:57 Voltage Offset Correction: v_off_ini = 3135.867 uV, v_off_fin = 3121.915 uV 19:07:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.198 uVs 19:07:57 Integrated Voltage Measurement... 19:08:06 Voltage Offset Correction: v_off_ini = 3102.491 uV, v_off_fin = 3139.358 uV 19:08:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.525 uVs 19:08:08 I2X Average and RMS of Measurements VT = -98.049 +- 6.200 uVs I2X = 9.021 +- 0.570 uTm^2 19:08:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:08:16 Integrated Voltage Measurement... 19:08:25 Voltage Offset Correction: v_off_ini = 3115.103 uV, v_off_fin = 3107.396 uV 19:08:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.025 uVs 19:08:25 Integrated Voltage Measurement... 19:08:34 Voltage Offset Correction: v_off_ini = 3048.973 uV, v_off_fin = 3118.286 uV 19:08:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.001 uVs 19:08:34 Integrated Voltage Measurement... 19:08:43 Voltage Offset Correction: v_off_ini = 3100.544 uV, v_off_fin = 3094.761 uV 19:08:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.131 uVs 19:08:43 Integrated Voltage Measurement... 19:08:52 Voltage Offset Correction: v_off_ini = 3097.011 uV, v_off_fin = 3094.488 uV 19:08:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.740 uVs 19:08:52 Integrated Voltage Measurement... 19:09:01 Voltage Offset Correction: v_off_ini = 3122.609 uV, v_off_fin = 3095.998 uV 19:09:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.713 uVs 19:09:01 Integrated Voltage Measurement... 19:09:10 Voltage Offset Correction: v_off_ini = 3083.994 uV, v_off_fin = 3085.934 uV 19:09:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.313 uVs 19:09:12 I2Y Average and RMS of Measurements VT = -280.987 +- 6.831 uVs I2Y = -25.851 +- 0.628 uTm^2 19:09:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:09:21 Integrated Voltage Measurement... 19:09:30 Voltage Offset Correction: v_off_ini = 3089.478 uV, v_off_fin = 3087.888 uV 19:09:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.599 uVs 19:09:30 Integrated Voltage Measurement... 19:09:39 Voltage Offset Correction: v_off_ini = 3085.074 uV, v_off_fin = 3090.506 uV 19:09:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.425 uVs 19:09:39 Integrated Voltage Measurement... 19:09:48 Voltage Offset Correction: v_off_ini = 3072.933 uV, v_off_fin = 3091.111 uV 19:09:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.972 uVs 19:09:48 Integrated Voltage Measurement... 19:09:57 Voltage Offset Correction: v_off_ini = 3074.230 uV, v_off_fin = 3079.811 uV 19:09:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.403 uVs 19:09:57 Integrated Voltage Measurement... 19:10:06 Voltage Offset Correction: v_off_ini = 3114.305 uV, v_off_fin = 3101.485 uV 19:10:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.453 uVs 19:10:06 Integrated Voltage Measurement... 19:10:15 Voltage Offset Correction: v_off_ini = 3100.788 uV, v_off_fin = 3096.528 uV 19:10:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.882 uVs 19:10:20 I1X Average and RMS of Measurements VT = -92.122 +- 13.303 uVs I1X = 18.425 +- 2.661 uTm 19:10:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:10:26 Integrated Voltage Measurement... 19:10:35 Voltage Offset Correction: v_off_ini = 3085.129 uV, v_off_fin = 3107.737 uV 19:10:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.092 uVs 19:10:35 Integrated Voltage Measurement... 19:10:44 Voltage Offset Correction: v_off_ini = 3091.967 uV, v_off_fin = 3081.810 uV 19:10:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.633 uVs 19:10:44 Integrated Voltage Measurement... 19:10:53 Voltage Offset Correction: v_off_ini = 3095.019 uV, v_off_fin = 3081.291 uV 19:10:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.120 uVs 19:10:53 Integrated Voltage Measurement... 19:11:02 Voltage Offset Correction: v_off_ini = 3086.268 uV, v_off_fin = 3097.791 uV 19:11:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.377 uVs 19:11:02 Integrated Voltage Measurement... 19:11:11 Voltage Offset Correction: v_off_ini = 3064.879 uV, v_off_fin = 3050.953 uV 19:11:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.939 uVs 19:11:11 Integrated Voltage Measurement... 19:11:20 Voltage Offset Correction: v_off_ini = 3066.542 uV, v_off_fin = 3045.383 uV 19:11:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.459 uVs 19:11:24 I1Y Average and RMS of Measurements VT = -186.103 +- 11.061 uVs I1Y = -37.221 +- 2.212 uTm 19:11:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:11:32 Integrated Voltage Measurement... 19:11:41 Voltage Offset Correction: v_off_ini = 3057.716 uV, v_off_fin = 3049.288 uV 19:11:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.307 uVs 19:11:41 Integrated Voltage Measurement... 19:11:50 Voltage Offset Correction: v_off_ini = 3074.251 uV, v_off_fin = 3040.384 uV 19:11:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.208 uVs 19:11:50 Integrated Voltage Measurement... 19:11:59 Voltage Offset Correction: v_off_ini = 3041.207 uV, v_off_fin = 3042.787 uV 19:11:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.672 uVs 19:11:59 Integrated Voltage Measurement... 19:12:08 Voltage Offset Correction: v_off_ini = 3019.518 uV, v_off_fin = 3045.387 uV 19:12:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.043 uVs 19:12:08 Integrated Voltage Measurement... 19:12:17 Voltage Offset Correction: v_off_ini = 3060.652 uV, v_off_fin = 3053.121 uV 19:12:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.702 uVs 19:12:17 Integrated Voltage Measurement... 19:12:26 Voltage Offset Correction: v_off_ini = 3017.621 uV, v_off_fin = 3019.229 uV 19:12:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.033 uVs 19:12:29 I2X Average and RMS of Measurements VT = -120.161 +- 10.374 uVs I2X = 11.055 +- 0.954 uTm^2 19:12:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:12:36 Integrated Voltage Measurement... 19:12:45 Voltage Offset Correction: v_off_ini = 3051.926 uV, v_off_fin = 3003.850 uV 19:12:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.296 uVs 19:12:45 Integrated Voltage Measurement... 19:12:54 Voltage Offset Correction: v_off_ini = 3014.044 uV, v_off_fin = 3053.041 uV 19:12:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.067 uVs 19:12:54 Integrated Voltage Measurement... 19:13:03 Voltage Offset Correction: v_off_ini = 3061.098 uV, v_off_fin = 3025.047 uV 19:13:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.119 uVs 19:13:03 Integrated Voltage Measurement... 19:13:12 Voltage Offset Correction: v_off_ini = 3010.982 uV, v_off_fin = 3017.013 uV 19:13:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.541 uVs 19:13:12 Integrated Voltage Measurement... 19:13:21 Voltage Offset Correction: v_off_ini = 3009.844 uV, v_off_fin = 3028.349 uV 19:13:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.578 uVs 19:13:22 Integrated Voltage Measurement... 19:13:30 Voltage Offset Correction: v_off_ini = 3053.219 uV, v_off_fin = 3011.557 uV 19:13:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.194 uVs 19:13:33 I2Y Average and RMS of Measurements VT = -284.132 +- 9.496 uVs I2Y = -26.140 +- 0.874 uTm^2 19:13:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:13:42 Integrated Voltage Measurement... 19:13:51 Voltage Offset Correction: v_off_ini = 3064.267 uV, v_off_fin = 3072.588 uV 19:13:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.103 uVs 19:13:51 Integrated Voltage Measurement... 19:14:00 Voltage Offset Correction: v_off_ini = 3063.175 uV, v_off_fin = 3068.992 uV 19:14:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.797 uVs 19:14:00 Integrated Voltage Measurement... 19:14:09 Voltage Offset Correction: v_off_ini = 3070.887 uV, v_off_fin = 3071.043 uV 19:14:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -99.280 uVs 19:14:09 Integrated Voltage Measurement... 19:14:18 Voltage Offset Correction: v_off_ini = 3098.200 uV, v_off_fin = 3092.403 uV 19:14:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.200 uVs 19:14:18 Integrated Voltage Measurement... 19:14:27 Voltage Offset Correction: v_off_ini = 3099.493 uV, v_off_fin = 3091.333 uV 19:14:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.101 uVs 19:14:27 Integrated Voltage Measurement... 19:14:36 Voltage Offset Correction: v_off_ini = 3093.693 uV, v_off_fin = 3072.520 uV 19:14:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.909 uVs 19:14:40 I1X Average and RMS of Measurements VT = -99.231 +- 2.139 uVs I1X = 19.848 +- 0.429 uTm 19:14:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:14:47 Integrated Voltage Measurement... 19:14:56 Voltage Offset Correction: v_off_ini = 3072.881 uV, v_off_fin = 3042.736 uV 19:14:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.076 uVs 19:14:56 Integrated Voltage Measurement... 19:15:05 Voltage Offset Correction: v_off_ini = 3062.237 uV, v_off_fin = 3101.647 uV 19:15:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.820 uVs 19:15:05 Integrated Voltage Measurement... 19:15:14 Voltage Offset Correction: v_off_ini = 3115.359 uV, v_off_fin = 3082.683 uV 19:15:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.958 uVs 19:15:14 Integrated Voltage Measurement... 19:15:23 Voltage Offset Correction: v_off_ini = 3083.893 uV, v_off_fin = 3111.375 uV 19:15:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.626 uVs 19:15:23 Integrated Voltage Measurement... 19:15:32 Voltage Offset Correction: v_off_ini = 3095.319 uV, v_off_fin = 3103.817 uV 19:15:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.440 uVs 19:15:32 Integrated Voltage Measurement... 19:15:41 Voltage Offset Correction: v_off_ini = 3079.311 uV, v_off_fin = 3095.300 uV 19:15:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.750 uVs 19:15:45 I1Y Average and RMS of Measurements VT = -193.445 +- 16.294 uVs I1Y = -38.689 +- 3.259 uTm 19:15:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:15:53 Integrated Voltage Measurement... 19:16:02 Voltage Offset Correction: v_off_ini = 3107.156 uV, v_off_fin = 3098.496 uV 19:16:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.598 uVs 19:16:02 Integrated Voltage Measurement... 19:16:11 Voltage Offset Correction: v_off_ini = 3112.367 uV, v_off_fin = 3102.143 uV 19:16:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.728 uVs 19:16:11 Integrated Voltage Measurement... 19:16:20 Voltage Offset Correction: v_off_ini = 3139.263 uV, v_off_fin = 3127.020 uV 19:16:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.857 uVs 19:16:20 Integrated Voltage Measurement... 19:16:29 Voltage Offset Correction: v_off_ini = 3109.887 uV, v_off_fin = 3127.464 uV 19:16:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.475 uVs 19:16:29 Integrated Voltage Measurement... 19:16:38 Voltage Offset Correction: v_off_ini = 3108.565 uV, v_off_fin = 3074.363 uV 19:16:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.053 uVs 19:16:38 Integrated Voltage Measurement... 19:16:47 Voltage Offset Correction: v_off_ini = 3129.100 uV, v_off_fin = 3119.850 uV 19:16:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.439 uVs 19:16:49 I2X Average and RMS of Measurements VT = -95.525 +- 17.195 uVs I2X = 8.788 +- 1.582 uTm^2 19:16:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:16:57 Integrated Voltage Measurement... 19:17:06 Voltage Offset Correction: v_off_ini = 3096.308 uV, v_off_fin = 3075.251 uV 19:17:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.861 uVs 19:17:06 Integrated Voltage Measurement... 19:17:15 Voltage Offset Correction: v_off_ini = 3080.051 uV, v_off_fin = 3067.961 uV 19:17:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.342 uVs 19:17:15 Integrated Voltage Measurement... 19:17:24 Voltage Offset Correction: v_off_ini = 3071.802 uV, v_off_fin = 3064.456 uV 19:17:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.457 uVs 19:17:24 Integrated Voltage Measurement... 19:17:33 Voltage Offset Correction: v_off_ini = 3072.479 uV, v_off_fin = 3089.769 uV 19:17:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.270 uVs 19:17:33 Integrated Voltage Measurement... 19:17:42 Voltage Offset Correction: v_off_ini = 3077.952 uV, v_off_fin = 3068.818 uV 19:17:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.888 uVs 19:17:42 Integrated Voltage Measurement... 19:17:51 Voltage Offset Correction: v_off_ini = 3066.729 uV, v_off_fin = 3081.982 uV 19:17:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.400 uVs 19:17:53 I2Y Average and RMS of Measurements VT = -290.369 +- 13.002 uVs I2Y = -26.714 +- 1.196 uTm^2 19:17:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:18:02 Integrated Voltage Measurement... 19:18:11 Voltage Offset Correction: v_off_ini = 3084.724 uV, v_off_fin = 3061.681 uV 19:18:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.631 uVs 19:18:11 Integrated Voltage Measurement... 19:18:20 Voltage Offset Correction: v_off_ini = 3051.595 uV, v_off_fin = 3073.272 uV 19:18:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.850 uVs 19:18:20 Integrated Voltage Measurement... 19:18:29 Voltage Offset Correction: v_off_ini = 3075.322 uV, v_off_fin = 3069.291 uV 19:18:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.408 uVs 19:18:29 Integrated Voltage Measurement... 19:18:38 Voltage Offset Correction: v_off_ini = 3073.920 uV, v_off_fin = 3097.306 uV 19:18:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.058 uVs 19:18:38 Integrated Voltage Measurement... 19:18:47 Voltage Offset Correction: v_off_ini = 3094.985 uV, v_off_fin = 3086.274 uV 19:18:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.721 uVs 19:18:47 Integrated Voltage Measurement... 19:18:56 Voltage Offset Correction: v_off_ini = 3091.442 uV, v_off_fin = 3034.585 uV 19:18:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.725 uVs 19:19:01 I1X Average and RMS of Measurements VT = -101.232 +- 25.784 uVs I1X = 20.247 +- 5.157 uTm 19:19:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:19:07 Integrated Voltage Measurement... 19:19:16 Voltage Offset Correction: v_off_ini = 3078.655 uV, v_off_fin = 3047.976 uV 19:19:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -192.407 uVs 19:19:16 Integrated Voltage Measurement... 19:19:25 Voltage Offset Correction: v_off_ini = 3078.538 uV, v_off_fin = 3084.669 uV 19:19:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 220.506 uVs 19:19:25 Integrated Voltage Measurement... 19:19:34 Voltage Offset Correction: v_off_ini = 3069.522 uV, v_off_fin = 3073.299 uV 19:19:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.285 uVs 19:19:34 Integrated Voltage Measurement... 19:19:43 Voltage Offset Correction: v_off_ini = 3106.608 uV, v_off_fin = 3097.432 uV 19:19:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.059 uVs 19:19:43 Integrated Voltage Measurement... 19:19:52 Voltage Offset Correction: v_off_ini = 3072.753 uV, v_off_fin = 3087.139 uV 19:19:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.689 uVs 19:19:52 Integrated Voltage Measurement... 19:20:01 Voltage Offset Correction: v_off_ini = 3089.222 uV, v_off_fin = 3093.695 uV 19:20:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.124 uVs 19:20:05 I1Y Average and RMS of Measurements VT = -201.345 +- 10.917 uVs I1Y = -40.270 +- 2.184 uTm 19:20:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:20:13 Integrated Voltage Measurement... 19:20:22 Voltage Offset Correction: v_off_ini = 3048.218 uV, v_off_fin = 3080.042 uV 19:20:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.769 uVs 19:20:22 Integrated Voltage Measurement... 19:20:31 Voltage Offset Correction: v_off_ini = 3084.404 uV, v_off_fin = 3072.869 uV 19:20:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.851 uVs 19:20:31 Integrated Voltage Measurement... 19:20:40 Voltage Offset Correction: v_off_ini = 3041.224 uV, v_off_fin = 3049.633 uV 19:20:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.607 uVs 19:20:40 Integrated Voltage Measurement... 19:20:49 Voltage Offset Correction: v_off_ini = 3057.286 uV, v_off_fin = 3043.920 uV 19:20:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 111.127 uVs 19:20:49 Integrated Voltage Measurement... 19:20:58 Voltage Offset Correction: v_off_ini = 3067.509 uV, v_off_fin = 3060.936 uV 19:20:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.805 uVs 19:20:58 Integrated Voltage Measurement... 19:21:07 Voltage Offset Correction: v_off_ini = 3062.248 uV, v_off_fin = 3099.478 uV 19:21:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.878 uVs 19:21:10 I2X Average and RMS of Measurements VT = -106.173 +- 18.554 uVs I2X = 9.768 +- 1.707 uTm^2 19:21:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:21:17 Integrated Voltage Measurement... 19:21:26 Voltage Offset Correction: v_off_ini = 3066.460 uV, v_off_fin = 3051.176 uV 19:21:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.361 uVs 19:21:26 Integrated Voltage Measurement... 19:21:35 Voltage Offset Correction: v_off_ini = 3029.052 uV, v_off_fin = 3109.005 uV 19:21:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.973 uVs 19:21:35 Integrated Voltage Measurement... 19:21:44 Voltage Offset Correction: v_off_ini = 3095.569 uV, v_off_fin = 3092.009 uV 19:21:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.698 uVs 19:21:45 Integrated Voltage Measurement... 19:21:53 Voltage Offset Correction: v_off_ini = 3080.904 uV, v_off_fin = 3116.333 uV 19:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.097 uVs 19:21:54 Integrated Voltage Measurement... 19:22:03 Voltage Offset Correction: v_off_ini = 3087.498 uV, v_off_fin = 3082.331 uV 19:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.664 uVs 19:22:03 Integrated Voltage Measurement... 19:22:12 Voltage Offset Correction: v_off_ini = 3088.287 uV, v_off_fin = 3083.674 uV 19:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.035 uVs 19:22:14 I2Y Average and RMS of Measurements VT = -302.805 +- 17.416 uVs I2Y = -27.858 +- 1.602 uTm^2 19:22:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:22:23 Integrated Voltage Measurement... 19:22:32 Voltage Offset Correction: v_off_ini = 3122.930 uV, v_off_fin = 3112.699 uV 19:22:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.649 uVs 19:22:32 Integrated Voltage Measurement... 19:22:41 Voltage Offset Correction: v_off_ini = 3108.668 uV, v_off_fin = 3118.537 uV 19:22:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.773 uVs 19:22:41 Integrated Voltage Measurement... 19:22:50 Voltage Offset Correction: v_off_ini = 3098.962 uV, v_off_fin = 3083.119 uV 19:22:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.893 uVs 19:22:50 Integrated Voltage Measurement... 19:22:59 Voltage Offset Correction: v_off_ini = 3082.869 uV, v_off_fin = 3084.304 uV 19:22:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.925 uVs 19:22:59 Integrated Voltage Measurement... 19:23:08 Voltage Offset Correction: v_off_ini = 3102.597 uV, v_off_fin = 3100.991 uV 19:23:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.537 uVs 19:23:08 Integrated Voltage Measurement... 19:23:17 Voltage Offset Correction: v_off_ini = 3123.048 uV, v_off_fin = 3119.967 uV 19:23:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.333 uVs 19:23:21 I1X Average and RMS of Measurements VT = -109.185 +- 10.257 uVs I1X = 21.838 +- 2.052 uTm 19:23:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:23:28 Integrated Voltage Measurement... 19:23:37 Voltage Offset Correction: v_off_ini = 3117.353 uV, v_off_fin = 3060.208 uV 19:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -212.682 uVs 19:23:37 Integrated Voltage Measurement... 19:23:46 Voltage Offset Correction: v_off_ini = 3069.631 uV, v_off_fin = 3111.600 uV 19:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.732 uVs 19:23:46 Integrated Voltage Measurement... 19:23:55 Voltage Offset Correction: v_off_ini = 3091.673 uV, v_off_fin = 3078.129 uV 19:23:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.121 uVs 19:23:55 Integrated Voltage Measurement... 19:24:04 Voltage Offset Correction: v_off_ini = 3082.297 uV, v_off_fin = 3073.443 uV 19:24:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.330 uVs 19:24:04 Integrated Voltage Measurement... 19:24:13 Voltage Offset Correction: v_off_ini = 3104.543 uV, v_off_fin = 3113.799 uV 19:24:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.610 uVs 19:24:13 Integrated Voltage Measurement... 19:24:22 Voltage Offset Correction: v_off_ini = 3101.798 uV, v_off_fin = 3110.107 uV 19:24:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.945 uVs 19:24:26 I1Y Average and RMS of Measurements VT = -196.570 +- 11.415 uVs I1Y = -39.315 +- 2.284 uTm 19:24:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:24:34 Integrated Voltage Measurement... 19:24:43 Voltage Offset Correction: v_off_ini = 3102.160 uV, v_off_fin = 3082.084 uV 19:24:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.775 uVs 19:24:43 Integrated Voltage Measurement... 19:24:52 Voltage Offset Correction: v_off_ini = 3049.948 uV, v_off_fin = 3079.226 uV 19:24:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.345 uVs 19:24:52 Integrated Voltage Measurement... 19:25:01 Voltage Offset Correction: v_off_ini = 3051.766 uV, v_off_fin = 3061.669 uV 19:25:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.902 uVs 19:25:01 Integrated Voltage Measurement... 19:25:10 Voltage Offset Correction: v_off_ini = 3090.968 uV, v_off_fin = 3101.654 uV 19:25:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.647 uVs 19:25:10 Integrated Voltage Measurement... 19:25:19 Voltage Offset Correction: v_off_ini = 3089.140 uV, v_off_fin = 3083.638 uV 19:25:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -109.167 uVs 19:25:19 Integrated Voltage Measurement... 19:25:28 Voltage Offset Correction: v_off_ini = 3071.323 uV, v_off_fin = 3066.668 uV 19:25:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 102.066 uVs 19:25:30 I2X Average and RMS of Measurements VT = -114.984 +- 6.720 uVs I2X = 10.579 +- 0.618 uTm^2 19:25:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:25:38 Integrated Voltage Measurement... 19:25:47 Voltage Offset Correction: v_off_ini = 3045.259 uV, v_off_fin = 3038.104 uV 19:25:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.938 uVs 19:25:47 Integrated Voltage Measurement... 19:25:56 Voltage Offset Correction: v_off_ini = 3079.314 uV, v_off_fin = 3062.741 uV 19:25:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.959 uVs 19:25:56 Integrated Voltage Measurement... 19:26:05 Voltage Offset Correction: v_off_ini = 3075.295 uV, v_off_fin = 3066.023 uV 19:26:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.486 uVs 19:26:05 Integrated Voltage Measurement... 19:26:14 Voltage Offset Correction: v_off_ini = 3051.609 uV, v_off_fin = 3049.703 uV 19:26:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.414 uVs 19:26:14 Integrated Voltage Measurement... 19:26:23 Voltage Offset Correction: v_off_ini = 3063.906 uV, v_off_fin = 3050.789 uV 19:26:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.695 uVs 19:26:23 Integrated Voltage Measurement... 19:26:32 Voltage Offset Correction: v_off_ini = 3030.603 uV, v_off_fin = 3050.863 uV 19:26:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.903 uVs 19:26:35 I2Y Average and RMS of Measurements VT = -292.399 +- 7.551 uVs I2Y = -26.901 +- 0.695 uTm^2 19:26:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:26:47 Integrated Voltage Measurement... 19:26:56 Voltage Offset Correction: v_off_ini = 3058.305 uV, v_off_fin = 3044.810 uV 19:26:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.950 uVs 19:26:56 Integrated Voltage Measurement... 19:27:05 Voltage Offset Correction: v_off_ini = 3034.886 uV, v_off_fin = 3034.329 uV 19:27:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.180 uVs 19:27:05 Integrated Voltage Measurement... 19:27:14 Voltage Offset Correction: v_off_ini = 3033.845 uV, v_off_fin = 3048.711 uV 19:27:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.675 uVs 19:27:14 Integrated Voltage Measurement... 19:27:23 Voltage Offset Correction: v_off_ini = 3057.493 uV, v_off_fin = 3044.848 uV 19:27:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.666 uVs 19:27:23 Integrated Voltage Measurement... 19:27:32 Voltage Offset Correction: v_off_ini = 3038.197 uV, v_off_fin = 3043.153 uV 19:27:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.560 uVs 19:27:32 Integrated Voltage Measurement... 19:27:41 Voltage Offset Correction: v_off_ini = 3050.810 uV, v_off_fin = 3040.603 uV 19:27:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 92.994 uVs 19:27:45 I1X Average and RMS of Measurements VT = -101.004 +- 3.391 uVs I1X = 20.201 +- 0.678 uTm 19:27:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:27:52 Integrated Voltage Measurement... 19:28:01 Voltage Offset Correction: v_off_ini = 3069.937 uV, v_off_fin = 3037.686 uV 19:28:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.700 uVs 19:28:01 Integrated Voltage Measurement... 19:28:10 Voltage Offset Correction: v_off_ini = 3035.224 uV, v_off_fin = 3060.268 uV 19:28:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.410 uVs 19:28:10 Integrated Voltage Measurement... 19:28:19 Voltage Offset Correction: v_off_ini = 3029.656 uV, v_off_fin = 3026.134 uV 19:28:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.062 uVs 19:28:19 Integrated Voltage Measurement... 19:28:28 Voltage Offset Correction: v_off_ini = 3059.410 uV, v_off_fin = 3031.737 uV 19:28:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.976 uVs 19:28:28 Integrated Voltage Measurement... 19:28:37 Voltage Offset Correction: v_off_ini = 3041.812 uV, v_off_fin = 3020.065 uV 19:28:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.402 uVs 19:28:37 Integrated Voltage Measurement... 19:28:46 Voltage Offset Correction: v_off_ini = 3035.262 uV, v_off_fin = 3078.389 uV 19:28:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.147 uVs 19:28:50 I1Y Average and RMS of Measurements VT = -182.449 +- 4.226 uVs I1Y = -36.490 +- 0.845 uTm 19:28:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:28:55 Integrated Voltage Measurement... 19:29:04 Voltage Offset Correction: v_off_ini = 3069.732 uV, v_off_fin = 3073.429 uV 19:29:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.607 uVs 19:29:04 Integrated Voltage Measurement... 19:29:13 Voltage Offset Correction: v_off_ini = 3060.611 uV, v_off_fin = 3074.915 uV 19:29:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.874 uVs 19:29:13 Integrated Voltage Measurement... 19:29:22 Voltage Offset Correction: v_off_ini = 3065.709 uV, v_off_fin = 3058.877 uV 19:29:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.450 uVs 19:29:22 Integrated Voltage Measurement... 19:29:31 Voltage Offset Correction: v_off_ini = 3039.910 uV, v_off_fin = 3058.003 uV 19:29:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.892 uVs 19:29:31 Integrated Voltage Measurement... 19:29:40 Voltage Offset Correction: v_off_ini = 3040.796 uV, v_off_fin = 3023.010 uV 19:29:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.799 uVs 19:29:40 Integrated Voltage Measurement... 19:29:49 Voltage Offset Correction: v_off_ini = 3049.178 uV, v_off_fin = 3032.205 uV 19:29:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.246 uVs 19:29:51 I2X Average and RMS of Measurements VT = -111.311 +- 14.137 uVs I2X = 10.241 +- 1.301 uTm^2 19:29:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:29:57 Integrated Voltage Measurement... 19:30:05 Voltage Offset Correction: v_off_ini = 3104.967 uV, v_off_fin = 3091.701 uV 19:30:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.995 uVs 19:30:06 Integrated Voltage Measurement... 19:30:15 Voltage Offset Correction: v_off_ini = 3067.390 uV, v_off_fin = 3081.011 uV 19:30:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.882 uVs 19:30:15 Integrated Voltage Measurement... 19:30:24 Voltage Offset Correction: v_off_ini = 3066.525 uV, v_off_fin = 3072.842 uV 19:30:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.892 uVs 19:30:24 Integrated Voltage Measurement... 19:30:33 Voltage Offset Correction: v_off_ini = 3109.328 uV, v_off_fin = 3093.848 uV 19:30:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.063 uVs 19:30:33 Integrated Voltage Measurement... 19:30:42 Voltage Offset Correction: v_off_ini = 3083.666 uV, v_off_fin = 3056.054 uV 19:30:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.749 uVs 19:30:42 Integrated Voltage Measurement... 19:30:51 Voltage Offset Correction: v_off_ini = 3064.023 uV, v_off_fin = 3056.394 uV 19:30:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.345 uVs 19:30:53 I2Y Average and RMS of Measurements VT = -301.821 +- 10.143 uVs I2Y = -27.768 +- 0.933 uTm^2 19:30:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:31:01 Integrated Voltage Measurement... 19:31:10 Voltage Offset Correction: v_off_ini = 3091.602 uV, v_off_fin = 3063.705 uV 19:31:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.829 uVs 19:31:10 Integrated Voltage Measurement... 19:31:19 Voltage Offset Correction: v_off_ini = 3075.234 uV, v_off_fin = 3058.068 uV 19:31:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 55.929 uVs 19:31:19 Integrated Voltage Measurement... 19:31:28 Voltage Offset Correction: v_off_ini = 3087.526 uV, v_off_fin = 3104.186 uV 19:31:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.166 uVs 19:31:28 Integrated Voltage Measurement... 19:31:37 Voltage Offset Correction: v_off_ini = 3095.540 uV, v_off_fin = 3088.757 uV 19:31:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.252 uVs 19:31:37 Integrated Voltage Measurement... 19:31:46 Voltage Offset Correction: v_off_ini = 3065.847 uV, v_off_fin = 3101.672 uV 19:31:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.920 uVs 19:31:46 Integrated Voltage Measurement... 19:31:55 Voltage Offset Correction: v_off_ini = 3101.418 uV, v_off_fin = 3084.682 uV 19:31:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.841 uVs 19:32:00 I1X Average and RMS of Measurements VT = -93.323 +- 17.764 uVs I1X = 18.665 +- 3.552 uTm 19:32:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:32:06 Integrated Voltage Measurement... 19:32:15 Voltage Offset Correction: v_off_ini = 3098.371 uV, v_off_fin = 3073.826 uV 19:32:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.686 uVs 19:32:15 Integrated Voltage Measurement... 19:32:24 Voltage Offset Correction: v_off_ini = 3103.997 uV, v_off_fin = 3097.634 uV 19:32:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.079 uVs 19:32:24 Integrated Voltage Measurement... 19:32:33 Voltage Offset Correction: v_off_ini = 3097.990 uV, v_off_fin = 3093.457 uV 19:32:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.657 uVs 19:32:33 Integrated Voltage Measurement... 19:32:42 Voltage Offset Correction: v_off_ini = 3086.176 uV, v_off_fin = 3114.185 uV 19:32:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.606 uVs 19:32:42 Integrated Voltage Measurement... 19:32:51 Voltage Offset Correction: v_off_ini = 3106.784 uV, v_off_fin = 3107.383 uV 19:32:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.195 uVs 19:32:51 Integrated Voltage Measurement... 19:33:00 Voltage Offset Correction: v_off_ini = 3101.347 uV, v_off_fin = 3121.018 uV 19:33:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.890 uVs 19:33:05 I1Y Average and RMS of Measurements VT = -185.019 +- 13.259 uVs I1Y = -37.004 +- 2.651 uTm 19:33:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:33:10 Integrated Voltage Measurement... 19:33:19 Voltage Offset Correction: v_off_ini = 3101.106 uV, v_off_fin = 3086.414 uV 19:33:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.748 uVs 19:33:19 Integrated Voltage Measurement... 19:33:28 Voltage Offset Correction: v_off_ini = 3092.509 uV, v_off_fin = 3105.528 uV 19:33:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.797 uVs 19:33:28 Integrated Voltage Measurement... 19:33:37 Voltage Offset Correction: v_off_ini = 3091.156 uV, v_off_fin = 3070.735 uV 19:33:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.672 uVs 19:33:37 Integrated Voltage Measurement... 19:33:46 Voltage Offset Correction: v_off_ini = 3116.318 uV, v_off_fin = 3113.177 uV 19:33:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 82.965 uVs 19:33:46 Integrated Voltage Measurement... 19:33:55 Voltage Offset Correction: v_off_ini = 3059.593 uV, v_off_fin = 3079.881 uV 19:33:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.398 uVs 19:33:55 Integrated Voltage Measurement... 19:34:04 Voltage Offset Correction: v_off_ini = 3071.471 uV, v_off_fin = 3108.049 uV 19:34:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.564 uVs 19:34:06 I2X Average and RMS of Measurements VT = -102.024 +- 6.690 uVs I2X = 9.386 +- 0.616 uTm^2 19:34:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:34:11 Integrated Voltage Measurement... 19:34:20 Voltage Offset Correction: v_off_ini = 3102.343 uV, v_off_fin = 3110.256 uV 19:34:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.874 uVs 19:34:20 Integrated Voltage Measurement... 19:34:29 Voltage Offset Correction: v_off_ini = 3109.700 uV, v_off_fin = 3091.092 uV 19:34:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.362 uVs 19:34:29 Integrated Voltage Measurement... 19:34:38 Voltage Offset Correction: v_off_ini = 3082.361 uV, v_off_fin = 3128.041 uV 19:34:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.964 uVs 19:34:38 Integrated Voltage Measurement... 19:34:47 Voltage Offset Correction: v_off_ini = 3099.820 uV, v_off_fin = 3091.981 uV 19:34:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.227 uVs 19:34:47 Integrated Voltage Measurement... 19:34:56 Voltage Offset Correction: v_off_ini = 3074.120 uV, v_off_fin = 3108.671 uV 19:34:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.096 uVs 19:34:56 Integrated Voltage Measurement... 19:35:05 Voltage Offset Correction: v_off_ini = 3130.171 uV, v_off_fin = 3113.221 uV 19:35:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.399 uVs 19:35:08 I2Y Average and RMS of Measurements VT = -297.320 +- 1.092 uVs I2Y = -27.353 +- 0.100 uTm^2 19:35:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:35:16 Integrated Voltage Measurement... 19:35:25 Voltage Offset Correction: v_off_ini = 3125.817 uV, v_off_fin = 3110.951 uV 19:35:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.358 uVs 19:35:25 Integrated Voltage Measurement... 19:35:34 Voltage Offset Correction: v_off_ini = 3087.529 uV, v_off_fin = 3078.075 uV 19:35:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.116 uVs 19:35:34 Integrated Voltage Measurement... 19:35:43 Voltage Offset Correction: v_off_ini = 3091.883 uV, v_off_fin = 3133.056 uV 19:35:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.118 uVs 19:35:43 Integrated Voltage Measurement... 19:35:52 Voltage Offset Correction: v_off_ini = 3099.866 uV, v_off_fin = 3101.313 uV 19:35:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.768 uVs 19:35:52 Integrated Voltage Measurement... 19:36:01 Voltage Offset Correction: v_off_ini = 3097.077 uV, v_off_fin = 3108.688 uV 19:36:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.675 uVs 19:36:01 Integrated Voltage Measurement... 19:36:10 Voltage Offset Correction: v_off_ini = 3069.641 uV, v_off_fin = 3097.461 uV 19:36:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.101 uVs 19:36:14 I1X Average and RMS of Measurements VT = -108.356 +- 9.546 uVs I1X = 21.671 +- 1.909 uTm 19:36:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:36:21 Integrated Voltage Measurement... 19:36:30 Voltage Offset Correction: v_off_ini = 3071.805 uV, v_off_fin = 3078.506 uV 19:36:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.943 uVs 19:36:30 Integrated Voltage Measurement... 19:36:39 Voltage Offset Correction: v_off_ini = 3114.764 uV, v_off_fin = 3104.864 uV 19:36:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.285 uVs 19:36:39 Integrated Voltage Measurement... 19:36:48 Voltage Offset Correction: v_off_ini = 3067.857 uV, v_off_fin = 3054.077 uV 19:36:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.662 uVs 19:36:48 Integrated Voltage Measurement... 19:36:57 Voltage Offset Correction: v_off_ini = 3099.080 uV, v_off_fin = 3079.939 uV 19:36:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.693 uVs 19:36:57 Integrated Voltage Measurement... 19:37:06 Voltage Offset Correction: v_off_ini = 3050.519 uV, v_off_fin = 3052.733 uV 19:37:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.860 uVs 19:37:06 Integrated Voltage Measurement... 19:37:15 Voltage Offset Correction: v_off_ini = 3060.725 uV, v_off_fin = 3052.285 uV 19:37:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.186 uVs 19:37:19 I1Y Average and RMS of Measurements VT = -200.938 +- 13.537 uVs I1Y = -40.188 +- 2.707 uTm 19:37:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:37:24 Integrated Voltage Measurement... 19:37:33 Voltage Offset Correction: v_off_ini = 3050.527 uV, v_off_fin = 3024.817 uV 19:37:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.044 uVs 19:37:33 Integrated Voltage Measurement... 19:37:42 Voltage Offset Correction: v_off_ini = 3083.550 uV, v_off_fin = 3068.237 uV 19:37:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.001 uVs 19:37:42 Integrated Voltage Measurement... 19:37:51 Voltage Offset Correction: v_off_ini = 3039.898 uV, v_off_fin = 3055.919 uV 19:37:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.621 uVs 19:37:51 Integrated Voltage Measurement... 19:38:00 Voltage Offset Correction: v_off_ini = 3058.204 uV, v_off_fin = 3055.282 uV 19:38:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.713 uVs 19:38:01 Integrated Voltage Measurement... 19:38:09 Voltage Offset Correction: v_off_ini = 3059.754 uV, v_off_fin = 3060.784 uV 19:38:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.132 uVs 19:38:10 Integrated Voltage Measurement... 19:38:19 Voltage Offset Correction: v_off_ini = 3089.638 uV, v_off_fin = 3089.796 uV 19:38:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.878 uVs 19:38:21 I2X Average and RMS of Measurements VT = -110.231 +- 11.266 uVs I2X = 10.141 +- 1.036 uTm^2 19:38:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:38:26 Integrated Voltage Measurement... 19:38:35 Voltage Offset Correction: v_off_ini = 3080.019 uV, v_off_fin = 3065.286 uV 19:38:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.459 uVs 19:38:35 Integrated Voltage Measurement... 19:38:44 Voltage Offset Correction: v_off_ini = 3060.300 uV, v_off_fin = 3052.899 uV 19:38:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.558 uVs 19:38:44 Integrated Voltage Measurement... 19:38:53 Voltage Offset Correction: v_off_ini = 3074.752 uV, v_off_fin = 3112.008 uV 19:38:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.394 uVs 19:38:53 Integrated Voltage Measurement... 19:39:02 Voltage Offset Correction: v_off_ini = 3092.064 uV, v_off_fin = 3099.361 uV 19:39:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.084 uVs 19:39:02 Integrated Voltage Measurement... 19:39:11 Voltage Offset Correction: v_off_ini = 3081.015 uV, v_off_fin = 3106.949 uV 19:39:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.785 uVs 19:39:11 Integrated Voltage Measurement... 19:39:20 Voltage Offset Correction: v_off_ini = 3103.465 uV, v_off_fin = 3100.170 uV 19:39:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.782 uVs 19:39:23 I2Y Average and RMS of Measurements VT = -297.344 +- 17.971 uVs I2Y = -27.356 +- 1.653 uTm^2 19:39:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:39:31 Integrated Voltage Measurement... 19:39:40 Voltage Offset Correction: v_off_ini = 3086.937 uV, v_off_fin = 3109.428 uV 19:39:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -141.615 uVs 19:39:40 Integrated Voltage Measurement... 19:39:49 Voltage Offset Correction: v_off_ini = 3096.517 uV, v_off_fin = 3103.863 uV 19:39:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.919 uVs 19:39:49 Integrated Voltage Measurement... 19:39:58 Voltage Offset Correction: v_off_ini = 3100.231 uV, v_off_fin = 3109.109 uV 19:39:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.645 uVs 19:39:58 Integrated Voltage Measurement... 19:40:07 Voltage Offset Correction: v_off_ini = 3084.830 uV, v_off_fin = 3125.969 uV 19:40:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.079 uVs 19:40:07 Integrated Voltage Measurement... 19:40:16 Voltage Offset Correction: v_off_ini = 3096.294 uV, v_off_fin = 3079.370 uV 19:40:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.420 uVs 19:40:16 Integrated Voltage Measurement... 19:40:25 Voltage Offset Correction: v_off_ini = 3096.593 uV, v_off_fin = 3098.913 uV 19:40:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.374 uVs 19:40:29 I1X Average and RMS of Measurements VT = -85.009 +- 29.611 uVs I1X = 17.004 +- 5.924 uTm 19:40:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:40:36 Integrated Voltage Measurement... 19:40:45 Voltage Offset Correction: v_off_ini = 3106.846 uV, v_off_fin = 3108.041 uV 19:40:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.458 uVs 19:40:45 Integrated Voltage Measurement... 19:40:54 Voltage Offset Correction: v_off_ini = 3089.718 uV, v_off_fin = 3129.609 uV 19:40:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.043 uVs 19:40:54 Integrated Voltage Measurement... 19:41:03 Voltage Offset Correction: v_off_ini = 3111.158 uV, v_off_fin = 3108.542 uV 19:41:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.728 uVs 19:41:03 Integrated Voltage Measurement... 19:41:12 Voltage Offset Correction: v_off_ini = 3123.847 uV, v_off_fin = 3129.592 uV 19:41:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.050 uVs 19:41:12 Integrated Voltage Measurement... 19:41:21 Voltage Offset Correction: v_off_ini = 3115.986 uV, v_off_fin = 3089.077 uV 19:41:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.468 uVs 19:41:21 Integrated Voltage Measurement... 19:41:30 Voltage Offset Correction: v_off_ini = 3090.617 uV, v_off_fin = 3107.400 uV 19:41:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.704 uVs 19:41:34 I1Y Average and RMS of Measurements VT = -206.075 +- 11.081 uVs I1Y = -41.215 +- 2.216 uTm 19:41:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:41:39 Integrated Voltage Measurement... 19:41:48 Voltage Offset Correction: v_off_ini = 3110.784 uV, v_off_fin = 3093.144 uV 19:41:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.754 uVs 19:41:48 Integrated Voltage Measurement... 19:41:57 Voltage Offset Correction: v_off_ini = 3084.482 uV, v_off_fin = 3094.717 uV 19:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.018 uVs 19:41:57 Integrated Voltage Measurement... 19:42:06 Voltage Offset Correction: v_off_ini = 3077.450 uV, v_off_fin = 3101.266 uV 19:42:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.156 uVs 19:42:06 Integrated Voltage Measurement... 19:42:15 Voltage Offset Correction: v_off_ini = 3097.055 uV, v_off_fin = 3114.760 uV 19:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.127 uVs 19:42:15 Integrated Voltage Measurement... 19:42:24 Voltage Offset Correction: v_off_ini = 3128.871 uV, v_off_fin = 3112.157 uV 19:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.419 uVs 19:42:24 Integrated Voltage Measurement... 19:42:33 Voltage Offset Correction: v_off_ini = 3092.812 uV, v_off_fin = 3111.612 uV 19:42:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.160 uVs 19:42:36 I2X Average and RMS of Measurements VT = -89.439 +- 9.549 uVs I2X = 8.228 +- 0.878 uTm^2 19:42:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:42:41 Integrated Voltage Measurement... 19:42:50 Voltage Offset Correction: v_off_ini = 3052.885 uV, v_off_fin = 3078.097 uV 19:42:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -360.129 uVs 19:42:50 Integrated Voltage Measurement... 19:42:59 Voltage Offset Correction: v_off_ini = 3120.824 uV, v_off_fin = 3092.557 uV 19:42:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.948 uVs 19:42:59 Integrated Voltage Measurement... 19:43:08 Voltage Offset Correction: v_off_ini = 3119.735 uV, v_off_fin = 3117.395 uV 19:43:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.315 uVs 19:43:08 Integrated Voltage Measurement... 19:43:17 Voltage Offset Correction: v_off_ini = 3116.072 uV, v_off_fin = 3119.155 uV 19:43:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.972 uVs 19:43:17 Integrated Voltage Measurement... 19:43:26 Voltage Offset Correction: v_off_ini = 3126.492 uV, v_off_fin = 3117.482 uV 19:43:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.806 uVs 19:43:26 Integrated Voltage Measurement... 19:43:35 Voltage Offset Correction: v_off_ini = 3106.977 uV, v_off_fin = 3098.288 uV 19:43:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.570 uVs 19:43:37 I2Y Average and RMS of Measurements VT = -302.623 +- 10.598 uVs I2Y = -27.841 +- 0.975 uTm^2 19:43:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:43:46 Integrated Voltage Measurement... 19:43:55 Voltage Offset Correction: v_off_ini = 3088.141 uV, v_off_fin = 3103.561 uV 19:43:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.606 uVs 19:43:55 Integrated Voltage Measurement... 19:44:04 Voltage Offset Correction: v_off_ini = 3068.228 uV, v_off_fin = 3084.566 uV 19:44:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.823 uVs 19:44:04 Integrated Voltage Measurement... 19:44:13 Voltage Offset Correction: v_off_ini = 3085.955 uV, v_off_fin = 3090.305 uV 19:44:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.921 uVs 19:44:13 Integrated Voltage Measurement... 19:44:22 Voltage Offset Correction: v_off_ini = 3054.119 uV, v_off_fin = 3080.973 uV 19:44:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.328 uVs 19:44:22 Integrated Voltage Measurement... 19:44:31 Voltage Offset Correction: v_off_ini = 3075.147 uV, v_off_fin = 3054.554 uV 19:44:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.938 uVs 19:44:31 Integrated Voltage Measurement... 19:44:40 Voltage Offset Correction: v_off_ini = 3078.477 uV, v_off_fin = 3073.468 uV 19:44:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.566 uVs 19:44:44 I1X Average and RMS of Measurements VT = -92.197 +- 7.114 uVs I1X = 18.440 +- 1.423 uTm 19:44:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:44:51 Integrated Voltage Measurement... 19:45:00 Voltage Offset Correction: v_off_ini = 3063.442 uV, v_off_fin = 3080.850 uV 19:45:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.690 uVs 19:45:00 Integrated Voltage Measurement... 19:45:09 Voltage Offset Correction: v_off_ini = 3077.594 uV, v_off_fin = 3067.204 uV 19:45:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.109 uVs 19:45:09 Integrated Voltage Measurement... 19:45:18 Voltage Offset Correction: v_off_ini = 3026.890 uV, v_off_fin = 3065.999 uV 19:45:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -171.004 uVs 19:45:18 Integrated Voltage Measurement... 19:45:27 Voltage Offset Correction: v_off_ini = 3066.767 uV, v_off_fin = 3068.078 uV 19:45:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.254 uVs 19:45:27 Integrated Voltage Measurement... 19:45:36 Voltage Offset Correction: v_off_ini = 3053.497 uV, v_off_fin = 3054.189 uV 19:45:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.887 uVs 19:45:36 Integrated Voltage Measurement... 19:45:45 Voltage Offset Correction: v_off_ini = 3064.422 uV, v_off_fin = 3088.677 uV 19:45:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.481 uVs 19:45:49 I1Y Average and RMS of Measurements VT = -194.237 +- 7.184 uVs I1Y = -38.845 +- 1.438 uTm 19:45:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:45:54 Integrated Voltage Measurement... 19:46:03 Voltage Offset Correction: v_off_ini = 3077.557 uV, v_off_fin = 3105.506 uV 19:46:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.233 uVs 19:46:03 Integrated Voltage Measurement... 19:46:12 Voltage Offset Correction: v_off_ini = 3074.210 uV, v_off_fin = 3108.649 uV 19:46:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.876 uVs 19:46:12 Integrated Voltage Measurement... 19:46:21 Voltage Offset Correction: v_off_ini = 3084.698 uV, v_off_fin = 3091.384 uV 19:46:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.742 uVs 19:46:21 Integrated Voltage Measurement... 19:46:30 Voltage Offset Correction: v_off_ini = 3077.440 uV, v_off_fin = 3098.894 uV 19:46:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.185 uVs 19:46:30 Integrated Voltage Measurement... 19:46:39 Voltage Offset Correction: v_off_ini = 3098.115 uV, v_off_fin = 3054.324 uV 19:46:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.941 uVs 19:46:39 Integrated Voltage Measurement... 19:46:48 Voltage Offset Correction: v_off_ini = 3064.865 uV, v_off_fin = 3083.066 uV 19:46:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.519 uVs 19:46:50 I2X Average and RMS of Measurements VT = -100.749 +- 9.676 uVs I2X = 9.269 +- 0.890 uTm^2 19:46:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:46:56 Integrated Voltage Measurement... 19:47:05 Voltage Offset Correction: v_off_ini = 3061.244 uV, v_off_fin = 3041.141 uV 19:47:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.929 uVs 19:47:05 Integrated Voltage Measurement... 19:47:14 Voltage Offset Correction: v_off_ini = 3068.135 uV, v_off_fin = 3083.426 uV 19:47:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.666 uVs 19:47:14 Integrated Voltage Measurement... 19:47:23 Voltage Offset Correction: v_off_ini = 3064.339 uV, v_off_fin = 3028.090 uV 19:47:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.366 uVs 19:47:23 Integrated Voltage Measurement... 19:47:32 Voltage Offset Correction: v_off_ini = 3057.556 uV, v_off_fin = 3059.673 uV 19:47:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.427 uVs 19:47:32 Integrated Voltage Measurement... 19:47:41 Voltage Offset Correction: v_off_ini = 3074.283 uV, v_off_fin = 3075.978 uV 19:47:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -300.856 uVs 19:47:41 Integrated Voltage Measurement... 19:47:50 Voltage Offset Correction: v_off_ini = 3054.737 uV, v_off_fin = 3063.159 uV 19:47:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.443 uVs 19:47:52 I2Y Average and RMS of Measurements VT = -303.281 +- 12.010 uVs I2Y = -27.902 +- 1.105 uTm^2 19:48:24 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:48:28 Integrated Voltage Measurement... 19:48:37 Voltage Offset Correction: v_off_ini = 3031.156 uV, v_off_fin = 3025.495 uV 19:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.605 uVs 19:48:37 Integrated Voltage Measurement... 19:48:46 Voltage Offset Correction: v_off_ini = 3044.416 uV, v_off_fin = 3038.151 uV 19:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.131 uVs 19:48:46 Integrated Voltage Measurement... 19:48:55 Voltage Offset Correction: v_off_ini = 3038.516 uV, v_off_fin = 3021.785 uV 19:48:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -34.828 uVs 19:48:55 Integrated Voltage Measurement... 19:49:04 Voltage Offset Correction: v_off_ini = 3036.413 uV, v_off_fin = 3053.222 uV 19:49:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.268 uVs 19:49:04 Integrated Voltage Measurement... 19:49:13 Voltage Offset Correction: v_off_ini = 3033.825 uV, v_off_fin = 3062.541 uV 19:49:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.063 uVs 19:49:13 Integrated Voltage Measurement... 19:49:22 Voltage Offset Correction: v_off_ini = 3036.151 uV, v_off_fin = 3032.206 uV 19:49:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.580 uVs 19:49:26 I1X Average and RMS of Measurements VT = -52.413 +- 6.031 uVs I1X = 10.483 +- 1.206 uTm 19:49:29 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:49:33 Integrated Voltage Measurement... 19:49:42 Voltage Offset Correction: v_off_ini = 3034.180 uV, v_off_fin = 3022.173 uV 19:49:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.521 uVs 19:49:42 Integrated Voltage Measurement... 19:49:51 Voltage Offset Correction: v_off_ini = 3035.715 uV, v_off_fin = 3059.167 uV 19:49:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.611 uVs 19:49:51 Integrated Voltage Measurement... 19:50:00 Voltage Offset Correction: v_off_ini = 3045.926 uV, v_off_fin = 3012.826 uV 19:50:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.966 uVs 19:50:00 Integrated Voltage Measurement... 19:50:09 Voltage Offset Correction: v_off_ini = 3033.761 uV, v_off_fin = 3049.937 uV 19:50:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.284 uVs 19:50:09 Integrated Voltage Measurement... 19:50:18 Voltage Offset Correction: v_off_ini = 3030.585 uV, v_off_fin = 3029.449 uV 19:50:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.611 uVs 19:50:18 Integrated Voltage Measurement... 19:50:27 Voltage Offset Correction: v_off_ini = 3026.788 uV, v_off_fin = 3055.574 uV 19:50:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.594 uVs 19:50:31 I1Y Average and RMS of Measurements VT = -206.764 +- 15.301 uVs I1Y = -41.353 +- 3.060 uTm 19:50:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:50:39 Integrated Voltage Measurement... 19:50:48 Voltage Offset Correction: v_off_ini = 3027.247 uV, v_off_fin = 3030.810 uV 19:50:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.859 uVs 19:50:48 Integrated Voltage Measurement... 19:50:57 Voltage Offset Correction: v_off_ini = 3049.880 uV, v_off_fin = 3052.476 uV 19:50:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.683 uVs 19:50:57 Integrated Voltage Measurement... 19:51:06 Voltage Offset Correction: v_off_ini = 3067.420 uV, v_off_fin = 3033.747 uV 19:51:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.781 uVs 19:51:06 Integrated Voltage Measurement... 19:51:15 Voltage Offset Correction: v_off_ini = 3057.775 uV, v_off_fin = 3046.280 uV 19:51:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.079 uVs 19:51:15 Integrated Voltage Measurement... 19:51:24 Voltage Offset Correction: v_off_ini = 3052.928 uV, v_off_fin = 3039.761 uV 19:51:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.298 uVs 19:51:24 Integrated Voltage Measurement... 19:51:33 Voltage Offset Correction: v_off_ini = 3042.623 uV, v_off_fin = 3054.925 uV 19:51:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.149 uVs 19:51:35 I2X Average and RMS of Measurements VT = -39.642 +- 15.745 uVs I2X = 3.647 +- 1.449 uTm^2 19:51:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:51:43 Integrated Voltage Measurement... 19:51:52 Voltage Offset Correction: v_off_ini = 3081.024 uV, v_off_fin = 3068.817 uV 19:51:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.435 uVs 19:51:52 Integrated Voltage Measurement... 19:52:01 Voltage Offset Correction: v_off_ini = 3082.519 uV, v_off_fin = 3062.260 uV 19:52:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.000 uVs 19:52:01 Integrated Voltage Measurement... 19:52:10 Voltage Offset Correction: v_off_ini = 3065.535 uV, v_off_fin = 3060.797 uV 19:52:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.948 uVs 19:52:10 Integrated Voltage Measurement... 19:52:19 Voltage Offset Correction: v_off_ini = 3095.819 uV, v_off_fin = 3090.395 uV 19:52:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.274 uVs 19:52:19 Integrated Voltage Measurement... 19:52:28 Voltage Offset Correction: v_off_ini = 3076.242 uV, v_off_fin = 3039.896 uV 19:52:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.079 uVs 19:52:28 Integrated Voltage Measurement... 19:52:37 Voltage Offset Correction: v_off_ini = 3064.862 uV, v_off_fin = 3084.495 uV 19:52:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.546 uVs 19:52:40 I2Y Average and RMS of Measurements VT = -230.214 +- 8.423 uVs I2Y = -21.180 +- 0.775 uTm^2 19:52:44 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:52:49 Integrated Voltage Measurement... 19:52:58 Voltage Offset Correction: v_off_ini = 3099.378 uV, v_off_fin = 3092.886 uV 19:52:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.172 uVs 19:52:58 Integrated Voltage Measurement... 19:53:07 Voltage Offset Correction: v_off_ini = 3088.080 uV, v_off_fin = 3064.494 uV 19:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.034 uVs 19:53:07 Integrated Voltage Measurement... 19:53:16 Voltage Offset Correction: v_off_ini = 3111.992 uV, v_off_fin = 3096.562 uV 19:53:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.992 uVs 19:53:16 Integrated Voltage Measurement... 19:53:25 Voltage Offset Correction: v_off_ini = 3107.231 uV, v_off_fin = 3108.679 uV 19:53:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.877 uVs 19:53:25 Integrated Voltage Measurement... 19:53:34 Voltage Offset Correction: v_off_ini = 3106.214 uV, v_off_fin = 3098.645 uV 19:53:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.619 uVs 19:53:34 Integrated Voltage Measurement... 19:53:43 Voltage Offset Correction: v_off_ini = 3080.778 uV, v_off_fin = 3079.465 uV 19:53:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -2.382 uVs 19:53:47 I1X Average and RMS of Measurements VT = -31.385 +- 8.524 uVs I1X = 6.277 +- 1.705 uTm 19:53:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:53:54 Integrated Voltage Measurement... 19:54:03 Voltage Offset Correction: v_off_ini = 3052.670 uV, v_off_fin = 3058.693 uV 19:54:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.713 uVs 19:54:03 Integrated Voltage Measurement... 19:54:12 Voltage Offset Correction: v_off_ini = 3089.583 uV, v_off_fin = 3098.933 uV 19:54:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.055 uVs 19:54:12 Integrated Voltage Measurement... 19:54:21 Voltage Offset Correction: v_off_ini = 3086.999 uV, v_off_fin = 3088.249 uV 19:54:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.681 uVs 19:54:21 Integrated Voltage Measurement... 19:54:30 Voltage Offset Correction: v_off_ini = 3087.675 uV, v_off_fin = 3109.921 uV 19:54:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.010 uVs 19:54:30 Integrated Voltage Measurement... 19:54:39 Voltage Offset Correction: v_off_ini = 3102.154 uV, v_off_fin = 3083.867 uV 19:54:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.766 uVs 19:54:39 Integrated Voltage Measurement... 19:54:48 Voltage Offset Correction: v_off_ini = 3110.248 uV, v_off_fin = 3128.464 uV 19:54:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.248 uVs 19:54:52 I1Y Average and RMS of Measurements VT = -194.079 +- 8.102 uVs I1Y = -38.816 +- 1.620 uTm 19:54:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:54:59 Integrated Voltage Measurement... 19:55:08 Voltage Offset Correction: v_off_ini = 3082.933 uV, v_off_fin = 3074.034 uV 19:55:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.742 uVs 19:55:08 Integrated Voltage Measurement... 19:55:17 Voltage Offset Correction: v_off_ini = 3123.830 uV, v_off_fin = 3123.974 uV 19:55:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.668 uVs 19:55:18 Integrated Voltage Measurement... 19:55:26 Voltage Offset Correction: v_off_ini = 3108.726 uV, v_off_fin = 3117.665 uV 19:55:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.370 uVs 19:55:27 Integrated Voltage Measurement... 19:55:36 Voltage Offset Correction: v_off_ini = 3122.652 uV, v_off_fin = 3118.258 uV 19:55:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.176 uVs 19:55:36 Integrated Voltage Measurement... 19:55:45 Voltage Offset Correction: v_off_ini = 3096.694 uV, v_off_fin = 3109.974 uV 19:55:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.994 uVs 19:55:45 Integrated Voltage Measurement... 19:55:54 Voltage Offset Correction: v_off_ini = 3111.305 uV, v_off_fin = 3100.358 uV 19:55:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.560 uVs 19:55:56 I2X Average and RMS of Measurements VT = -45.252 +- 5.337 uVs I2X = 4.163 +- 0.491 uTm^2 19:56:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:56:04 Integrated Voltage Measurement... 19:56:13 Voltage Offset Correction: v_off_ini = 3092.917 uV, v_off_fin = 3104.547 uV 19:56:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.238 uVs 19:56:13 Integrated Voltage Measurement... 19:56:22 Voltage Offset Correction: v_off_ini = 3095.426 uV, v_off_fin = 3107.347 uV 19:56:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.963 uVs 19:56:22 Integrated Voltage Measurement... 19:56:31 Voltage Offset Correction: v_off_ini = 3101.204 uV, v_off_fin = 3105.118 uV 19:56:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.352 uVs 19:56:31 Integrated Voltage Measurement... 19:56:40 Voltage Offset Correction: v_off_ini = 3096.375 uV, v_off_fin = 3091.630 uV 19:56:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 246.403 uVs 19:56:40 Integrated Voltage Measurement... 19:56:49 Voltage Offset Correction: v_off_ini = 3100.934 uV, v_off_fin = 3085.123 uV 19:56:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.390 uVs 19:56:49 Integrated Voltage Measurement... 19:56:58 Voltage Offset Correction: v_off_ini = 3096.664 uV, v_off_fin = 3102.511 uV 19:56:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.142 uVs 19:57:00 I2Y Average and RMS of Measurements VT = -240.748 +- 3.524 uVs I2Y = -22.149 +- 0.324 uTm^2 19:57:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:57:09 Integrated Voltage Measurement... 19:57:18 Voltage Offset Correction: v_off_ini = 3102.203 uV, v_off_fin = 3064.878 uV 19:57:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.430 uVs 19:57:18 Integrated Voltage Measurement... 19:57:27 Voltage Offset Correction: v_off_ini = 3090.203 uV, v_off_fin = 3084.099 uV 19:57:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.820 uVs 19:57:27 Integrated Voltage Measurement... 19:57:36 Voltage Offset Correction: v_off_ini = 3114.015 uV, v_off_fin = 3130.499 uV 19:57:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.857 uVs 19:57:36 Integrated Voltage Measurement... 19:57:45 Voltage Offset Correction: v_off_ini = 3126.016 uV, v_off_fin = 3105.152 uV 19:57:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.208 uVs 19:57:45 Integrated Voltage Measurement... 19:57:54 Voltage Offset Correction: v_off_ini = 3104.629 uV, v_off_fin = 3118.805 uV 19:57:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -11.837 uVs 19:57:54 Integrated Voltage Measurement... 19:58:03 Voltage Offset Correction: v_off_ini = 3118.897 uV, v_off_fin = 3161.274 uV 19:58:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.247 uVs 19:58:07 I1X Average and RMS of Measurements VT = -40.733 +- 9.221 uVs I1X = 8.147 +- 1.844 uTm 19:58:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:58:14 Integrated Voltage Measurement... 19:58:23 Voltage Offset Correction: v_off_ini = 3128.315 uV, v_off_fin = 3126.479 uV 19:58:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.033 uVs 19:58:23 Integrated Voltage Measurement... 19:58:32 Voltage Offset Correction: v_off_ini = 3134.738 uV, v_off_fin = 3125.202 uV 19:58:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.603 uVs 19:58:32 Integrated Voltage Measurement... 19:58:41 Voltage Offset Correction: v_off_ini = 3132.612 uV, v_off_fin = 3116.652 uV 19:58:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.119 uVs 19:58:41 Integrated Voltage Measurement... 19:58:50 Voltage Offset Correction: v_off_ini = 3126.370 uV, v_off_fin = 3120.972 uV 19:58:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.550 uVs 19:58:50 Integrated Voltage Measurement... 19:58:59 Voltage Offset Correction: v_off_ini = 3092.292 uV, v_off_fin = 3087.744 uV 19:58:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.796 uVs 19:58:59 Integrated Voltage Measurement... 19:59:08 Voltage Offset Correction: v_off_ini = 3109.558 uV, v_off_fin = 3140.681 uV 19:59:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.184 uVs 19:59:12 I1Y Average and RMS of Measurements VT = -186.714 +- 7.022 uVs I1Y = -37.343 +- 1.404 uTm 19:59:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:59:20 Integrated Voltage Measurement... 19:59:29 Voltage Offset Correction: v_off_ini = 3103.440 uV, v_off_fin = 3093.303 uV 19:59:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.217 uVs 19:59:29 Integrated Voltage Measurement... 19:59:38 Voltage Offset Correction: v_off_ini = 3091.724 uV, v_off_fin = 3153.776 uV 19:59:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.543 uVs 19:59:38 Integrated Voltage Measurement... 19:59:47 Voltage Offset Correction: v_off_ini = 3133.965 uV, v_off_fin = 3118.313 uV 19:59:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.990 uVs 19:59:47 Integrated Voltage Measurement... 19:59:56 Voltage Offset Correction: v_off_ini = 3147.436 uV, v_off_fin = 3160.244 uV 19:59:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.369 uVs 19:59:56 Integrated Voltage Measurement... 20:00:05 Voltage Offset Correction: v_off_ini = 3153.504 uV, v_off_fin = 3123.900 uV 20:00:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.470 uVs 20:00:05 Integrated Voltage Measurement... 20:00:14 Voltage Offset Correction: v_off_ini = 3124.389 uV, v_off_fin = 3136.524 uV 20:00:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.377 uVs 20:00:17 I2X Average and RMS of Measurements VT = -40.828 +- 8.054 uVs I2X = 3.756 +- 0.741 uTm^2 20:00:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:00:24 Integrated Voltage Measurement... 20:00:33 Voltage Offset Correction: v_off_ini = 3125.106 uV, v_off_fin = 3134.271 uV 20:00:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.431 uVs 20:00:33 Integrated Voltage Measurement... 20:00:42 Voltage Offset Correction: v_off_ini = 3119.054 uV, v_off_fin = 3125.145 uV 20:00:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.134 uVs 20:00:42 Integrated Voltage Measurement... 20:00:51 Voltage Offset Correction: v_off_ini = 3127.827 uV, v_off_fin = 3147.429 uV 20:00:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.096 uVs 20:00:51 Integrated Voltage Measurement... 20:01:00 Voltage Offset Correction: v_off_ini = 3138.004 uV, v_off_fin = 3124.031 uV 20:01:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.457 uVs 20:01:00 Integrated Voltage Measurement... 20:01:09 Voltage Offset Correction: v_off_ini = 3144.468 uV, v_off_fin = 3146.789 uV 20:01:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.685 uVs 20:01:09 Integrated Voltage Measurement... 20:01:18 Voltage Offset Correction: v_off_ini = 3140.422 uV, v_off_fin = 3106.159 uV 20:01:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.076 uVs 20:01:21 I2Y Average and RMS of Measurements VT = -223.480 +- 9.638 uVs I2Y = -20.560 +- 0.887 uTm^2 20:01:26 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:01:30 Integrated Voltage Measurement... 20:01:39 Voltage Offset Correction: v_off_ini = 3106.625 uV, v_off_fin = 3105.795 uV 20:01:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -38.808 uVs 20:01:39 Integrated Voltage Measurement... 20:01:48 Voltage Offset Correction: v_off_ini = 3083.716 uV, v_off_fin = 3137.334 uV 20:01:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.574 uVs 20:01:48 Integrated Voltage Measurement... 20:01:57 Voltage Offset Correction: v_off_ini = 3119.760 uV, v_off_fin = 3101.873 uV 20:01:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.760 uVs 20:01:57 Integrated Voltage Measurement... 20:02:06 Voltage Offset Correction: v_off_ini = 3131.784 uV, v_off_fin = 3134.636 uV 20:02:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.339 uVs 20:02:06 Integrated Voltage Measurement... 20:02:15 Voltage Offset Correction: v_off_ini = 3147.212 uV, v_off_fin = 3144.187 uV 20:02:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.349 uVs 20:02:15 Integrated Voltage Measurement... 20:02:24 Voltage Offset Correction: v_off_ini = 3148.735 uV, v_off_fin = 3154.708 uV 20:02:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.907 uVs 20:02:28 I1X Average and RMS of Measurements VT = -45.956 +- 6.946 uVs I1X = 9.191 +- 1.389 uTm 20:02:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:02:35 Integrated Voltage Measurement... 20:02:44 Voltage Offset Correction: v_off_ini = 3148.116 uV, v_off_fin = 3136.155 uV 20:02:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -209.994 uVs 20:02:44 Integrated Voltage Measurement... 20:02:53 Voltage Offset Correction: v_off_ini = 3120.643 uV, v_off_fin = 3136.191 uV 20:02:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.584 uVs 20:02:53 Integrated Voltage Measurement... 20:03:02 Voltage Offset Correction: v_off_ini = 3117.353 uV, v_off_fin = 3121.456 uV 20:03:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.186 uVs 20:03:02 Integrated Voltage Measurement... 20:03:11 Voltage Offset Correction: v_off_ini = 3112.134 uV, v_off_fin = 3127.668 uV 20:03:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.777 uVs 20:03:11 Integrated Voltage Measurement... 20:03:20 Voltage Offset Correction: v_off_ini = 3137.078 uV, v_off_fin = 3118.438 uV 20:03:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.630 uVs 20:03:20 Integrated Voltage Measurement... 20:03:29 Voltage Offset Correction: v_off_ini = 3109.224 uV, v_off_fin = 3105.459 uV 20:03:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.340 uVs 20:03:33 I1Y Average and RMS of Measurements VT = -202.085 +- 5.375 uVs I1Y = -40.418 +- 1.075 uTm 20:03:38 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:03:41 Integrated Voltage Measurement... 20:03:50 Voltage Offset Correction: v_off_ini = 3127.952 uV, v_off_fin = 3112.061 uV 20:03:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.181 uVs 20:03:50 Integrated Voltage Measurement... 20:03:59 Voltage Offset Correction: v_off_ini = 3115.404 uV, v_off_fin = 3119.232 uV 20:03:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.823 uVs 20:03:59 Integrated Voltage Measurement... 20:04:08 Voltage Offset Correction: v_off_ini = 3074.719 uV, v_off_fin = 3084.630 uV 20:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.894 uVs 20:04:08 Integrated Voltage Measurement... 20:04:17 Voltage Offset Correction: v_off_ini = 3069.109 uV, v_off_fin = 3096.591 uV 20:04:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.056 uVs 20:04:17 Integrated Voltage Measurement... 20:04:26 Voltage Offset Correction: v_off_ini = 3083.512 uV, v_off_fin = 3058.804 uV 20:04:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.439 uVs 20:04:26 Integrated Voltage Measurement... 20:04:35 Voltage Offset Correction: v_off_ini = 3050.462 uV, v_off_fin = 3098.039 uV 20:04:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.263 uVs 20:04:37 I2X Average and RMS of Measurements VT = -55.609 +- 5.644 uVs I2X = 5.116 +- 0.519 uTm^2 20:04:42 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:04:45 Integrated Voltage Measurement... 20:04:54 Voltage Offset Correction: v_off_ini = 3105.012 uV, v_off_fin = 3101.848 uV 20:04:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.848 uVs 20:04:54 Integrated Voltage Measurement... 20:05:03 Voltage Offset Correction: v_off_ini = 3104.186 uV, v_off_fin = 3107.806 uV 20:05:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.180 uVs 20:05:03 Integrated Voltage Measurement... 20:05:12 Voltage Offset Correction: v_off_ini = 3128.810 uV, v_off_fin = 3145.568 uV 20:05:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.654 uVs 20:05:12 Integrated Voltage Measurement... 20:05:21 Voltage Offset Correction: v_off_ini = 3149.859 uV, v_off_fin = 3128.223 uV 20:05:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.873 uVs 20:05:21 Integrated Voltage Measurement... 20:05:30 Voltage Offset Correction: v_off_ini = 3132.194 uV, v_off_fin = 3114.258 uV 20:05:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.039 uVs 20:05:30 Integrated Voltage Measurement... 20:05:39 Voltage Offset Correction: v_off_ini = 3127.936 uV, v_off_fin = 3125.856 uV 20:05:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.574 uVs 20:05:41 I2Y Average and RMS of Measurements VT = -245.695 +- 12.071 uVs I2Y = -22.604 +- 1.110 uTm^2 20:05:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:05:50 Integrated Voltage Measurement... 20:05:59 Voltage Offset Correction: v_off_ini = 3118.559 uV, v_off_fin = 3129.178 uV 20:05:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.279 uVs 20:05:59 Integrated Voltage Measurement... 20:06:08 Voltage Offset Correction: v_off_ini = 3137.443 uV, v_off_fin = 3129.342 uV 20:06:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.177 uVs 20:06:08 Integrated Voltage Measurement... 20:06:17 Voltage Offset Correction: v_off_ini = 3142.387 uV, v_off_fin = 3138.540 uV 20:06:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.249 uVs 20:06:17 Integrated Voltage Measurement... 20:06:26 Voltage Offset Correction: v_off_ini = 3113.442 uV, v_off_fin = 3104.125 uV 20:06:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.059 uVs 20:06:26 Integrated Voltage Measurement... 20:06:35 Voltage Offset Correction: v_off_ini = 3114.279 uV, v_off_fin = 3124.917 uV 20:06:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.741 uVs 20:06:35 Integrated Voltage Measurement... 20:06:44 Voltage Offset Correction: v_off_ini = 3133.710 uV, v_off_fin = 3123.258 uV 20:06:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.526 uVs 20:06:49 I1X Average and RMS of Measurements VT = -44.505 +- 10.240 uVs I1X = 8.901 +- 2.048 uTm 20:06:51 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:06:55 Integrated Voltage Measurement... 20:07:04 Voltage Offset Correction: v_off_ini = 3111.574 uV, v_off_fin = 3129.428 uV 20:07:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.756 uVs 20:07:04 Integrated Voltage Measurement... 20:07:13 Voltage Offset Correction: v_off_ini = 3135.510 uV, v_off_fin = 3130.500 uV 20:07:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.073 uVs 20:07:13 Integrated Voltage Measurement... 20:07:22 Voltage Offset Correction: v_off_ini = 3099.217 uV, v_off_fin = 3099.012 uV 20:07:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.201 uVs 20:07:22 Integrated Voltage Measurement... 20:07:31 Voltage Offset Correction: v_off_ini = 3127.969 uV, v_off_fin = 3130.325 uV 20:07:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.425 uVs 20:07:31 Integrated Voltage Measurement... 20:07:40 Voltage Offset Correction: v_off_ini = 3118.495 uV, v_off_fin = 3103.153 uV 20:07:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.223 uVs 20:07:40 Integrated Voltage Measurement... 20:07:49 Voltage Offset Correction: v_off_ini = 3115.477 uV, v_off_fin = 3100.423 uV 20:07:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.386 uVs 20:07:54 I1Y Average and RMS of Measurements VT = -198.678 +- 6.909 uVs I1Y = -39.736 +- 1.382 uTm 20:07:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:08:01 Integrated Voltage Measurement... 20:08:10 Voltage Offset Correction: v_off_ini = 3096.226 uV, v_off_fin = 3120.150 uV 20:08:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.005 uVs 20:08:10 Integrated Voltage Measurement... 20:08:19 Voltage Offset Correction: v_off_ini = 3092.702 uV, v_off_fin = 3129.708 uV 20:08:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.430 uVs 20:08:19 Integrated Voltage Measurement... 20:08:28 Voltage Offset Correction: v_off_ini = 3155.228 uV, v_off_fin = 3099.929 uV 20:08:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.443 uVs 20:08:28 Integrated Voltage Measurement... 20:08:37 Voltage Offset Correction: v_off_ini = 3120.522 uV, v_off_fin = 3155.466 uV 20:08:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.307 uVs 20:08:37 Integrated Voltage Measurement... 20:08:46 Voltage Offset Correction: v_off_ini = 3137.294 uV, v_off_fin = 3125.601 uV 20:08:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.831 uVs 20:08:46 Integrated Voltage Measurement... 20:08:55 Voltage Offset Correction: v_off_ini = 3118.831 uV, v_off_fin = 3121.584 uV 20:08:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.127 uVs 20:08:58 I2X Average and RMS of Measurements VT = -52.690 +- 7.066 uVs I2X = 4.848 +- 0.650 uTm^2 20:09:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:09:06 Integrated Voltage Measurement... 20:09:15 Voltage Offset Correction: v_off_ini = 3133.601 uV, v_off_fin = 3117.930 uV 20:09:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.292 uVs 20:09:15 Integrated Voltage Measurement... 20:09:24 Voltage Offset Correction: v_off_ini = 3094.329 uV, v_off_fin = 3123.138 uV 20:09:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.820 uVs 20:09:24 Integrated Voltage Measurement... 20:09:33 Voltage Offset Correction: v_off_ini = 3107.385 uV, v_off_fin = 3140.237 uV 20:09:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.851 uVs 20:09:33 Integrated Voltage Measurement... 20:09:42 Voltage Offset Correction: v_off_ini = 3119.765 uV, v_off_fin = 3125.793 uV 20:09:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.729 uVs 20:09:42 Integrated Voltage Measurement... 20:09:51 Voltage Offset Correction: v_off_ini = 3138.486 uV, v_off_fin = 3131.043 uV 20:09:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.576 uVs 20:09:51 Integrated Voltage Measurement... 20:10:00 Voltage Offset Correction: v_off_ini = 3163.205 uV, v_off_fin = 3137.518 uV 20:10:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.071 uVs 20:10:02 I2Y Average and RMS of Measurements VT = -237.057 +- 9.908 uVs I2Y = -21.809 +- 0.912 uTm^2 20:10:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:10:14 Integrated Voltage Measurement... 20:10:23 Voltage Offset Correction: v_off_ini = 3111.156 uV, v_off_fin = 3102.354 uV 20:10:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.769 uVs 20:10:23 Integrated Voltage Measurement... 20:10:32 Voltage Offset Correction: v_off_ini = 3120.743 uV, v_off_fin = 3136.134 uV 20:10:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.756 uVs 20:10:32 Integrated Voltage Measurement... 20:10:41 Voltage Offset Correction: v_off_ini = 3111.511 uV, v_off_fin = 3101.885 uV 20:10:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -10.541 uVs 20:10:41 Integrated Voltage Measurement... 20:10:50 Voltage Offset Correction: v_off_ini = 3104.347 uV, v_off_fin = 3121.538 uV 20:10:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.980 uVs 20:10:50 Integrated Voltage Measurement... 20:10:59 Voltage Offset Correction: v_off_ini = 3105.167 uV, v_off_fin = 3108.334 uV 20:10:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.016 uVs 20:10:59 Integrated Voltage Measurement... 20:11:08 Voltage Offset Correction: v_off_ini = 3130.947 uV, v_off_fin = 3128.938 uV 20:11:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.001 uVs 20:11:12 I1X Average and RMS of Measurements VT = -39.177 +- 14.737 uVs I1X = 7.836 +- 2.947 uTm 20:11:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:11:19 Integrated Voltage Measurement... 20:11:28 Voltage Offset Correction: v_off_ini = 3118.251 uV, v_off_fin = 3115.464 uV 20:11:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.525 uVs 20:11:28 Integrated Voltage Measurement... 20:11:37 Voltage Offset Correction: v_off_ini = 3148.602 uV, v_off_fin = 3163.771 uV 20:11:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.883 uVs 20:11:37 Integrated Voltage Measurement... 20:11:46 Voltage Offset Correction: v_off_ini = 3147.279 uV, v_off_fin = 3144.721 uV 20:11:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.313 uVs 20:11:46 Integrated Voltage Measurement... 20:11:55 Voltage Offset Correction: v_off_ini = 3173.976 uV, v_off_fin = 3175.424 uV 20:11:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.995 uVs 20:11:55 Integrated Voltage Measurement... 20:12:04 Voltage Offset Correction: v_off_ini = 3142.564 uV, v_off_fin = 3095.786 uV 20:12:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.900 uVs 20:12:04 Integrated Voltage Measurement... 20:12:13 Voltage Offset Correction: v_off_ini = 3118.362 uV, v_off_fin = 3140.687 uV 20:12:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.798 uVs 20:12:17 I1Y Average and RMS of Measurements VT = -202.069 +- 5.417 uVs I1Y = -40.414 +- 1.083 uTm 20:12:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:12:22 Integrated Voltage Measurement... 20:12:31 Voltage Offset Correction: v_off_ini = 3145.227 uV, v_off_fin = 3144.463 uV 20:12:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.357 uVs 20:12:31 Integrated Voltage Measurement... 20:12:40 Voltage Offset Correction: v_off_ini = 3137.724 uV, v_off_fin = 3157.959 uV 20:12:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -35.681 uVs 20:12:40 Integrated Voltage Measurement... 20:12:49 Voltage Offset Correction: v_off_ini = 3164.634 uV, v_off_fin = 3121.310 uV 20:12:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 4.404 uVs 20:12:49 Integrated Voltage Measurement... 20:12:58 Voltage Offset Correction: v_off_ini = 3128.714 uV, v_off_fin = 3151.515 uV 20:12:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.730 uVs 20:12:58 Integrated Voltage Measurement... 20:13:07 Voltage Offset Correction: v_off_ini = 3137.764 uV, v_off_fin = 3111.787 uV 20:13:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.973 uVs 20:13:08 Integrated Voltage Measurement... 20:13:17 Voltage Offset Correction: v_off_ini = 3134.105 uV, v_off_fin = 3137.599 uV 20:13:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.876 uVs 20:13:19 I2X Average and RMS of Measurements VT = -16.975 +- 15.270 uVs I2X = 1.562 +- 1.405 uTm^2 20:13:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:13:24 Integrated Voltage Measurement... 20:13:33 Voltage Offset Correction: v_off_ini = 3139.130 uV, v_off_fin = 3140.610 uV 20:13:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.220 uVs 20:13:33 Integrated Voltage Measurement... 20:13:42 Voltage Offset Correction: v_off_ini = 3116.497 uV, v_off_fin = 3153.768 uV 20:13:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.008 uVs 20:13:42 Integrated Voltage Measurement... 20:13:51 Voltage Offset Correction: v_off_ini = 3118.560 uV, v_off_fin = 3158.596 uV 20:13:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.329 uVs 20:13:51 Integrated Voltage Measurement... 20:14:00 Voltage Offset Correction: v_off_ini = 3149.514 uV, v_off_fin = 3135.298 uV 20:14:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.216 uVs 20:14:00 Integrated Voltage Measurement... 20:14:09 Voltage Offset Correction: v_off_ini = 3148.495 uV, v_off_fin = 3152.435 uV 20:14:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.211 uVs 20:14:09 Integrated Voltage Measurement... 20:14:18 Voltage Offset Correction: v_off_ini = 3123.597 uV, v_off_fin = 3105.584 uV 20:14:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.522 uVs 20:14:21 I2Y Average and RMS of Measurements VT = -253.084 +- 18.172 uVs I2Y = -23.284 +- 1.672 uTm^2 20:14:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:14:29 Integrated Voltage Measurement... 20:14:38 Voltage Offset Correction: v_off_ini = 3129.007 uV, v_off_fin = 3144.671 uV 20:14:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -25.107 uVs 20:14:38 Integrated Voltage Measurement... 20:14:47 Voltage Offset Correction: v_off_ini = 3127.257 uV, v_off_fin = 3135.163 uV 20:14:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.275 uVs 20:14:47 Integrated Voltage Measurement... 20:14:56 Voltage Offset Correction: v_off_ini = 3124.068 uV, v_off_fin = 3171.554 uV 20:14:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.877 uVs 20:14:56 Integrated Voltage Measurement... 20:15:05 Voltage Offset Correction: v_off_ini = 3170.038 uV, v_off_fin = 3171.075 uV 20:15:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 15.919 uVs 20:15:05 Integrated Voltage Measurement... 20:15:14 Voltage Offset Correction: v_off_ini = 3172.291 uV, v_off_fin = 3147.727 uV 20:15:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -6.966 uVs 20:15:14 Integrated Voltage Measurement... 20:15:23 Voltage Offset Correction: v_off_ini = 3140.623 uV, v_off_fin = 3177.333 uV 20:15:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.004 uVs 20:15:27 I1X Average and RMS of Measurements VT = -39.358 +- 10.940 uVs I1X = 7.872 +- 2.188 uTm 20:15:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:15:34 Integrated Voltage Measurement... 20:15:43 Voltage Offset Correction: v_off_ini = 3152.274 uV, v_off_fin = 3142.183 uV 20:15:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.042 uVs 20:15:43 Integrated Voltage Measurement... 20:15:52 Voltage Offset Correction: v_off_ini = 3148.531 uV, v_off_fin = 3145.144 uV 20:15:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.728 uVs 20:15:52 Integrated Voltage Measurement... 20:16:01 Voltage Offset Correction: v_off_ini = 3116.027 uV, v_off_fin = 3128.217 uV 20:16:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.783 uVs 20:16:01 Integrated Voltage Measurement... 20:16:10 Voltage Offset Correction: v_off_ini = 3156.670 uV, v_off_fin = 3135.385 uV 20:16:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.660 uVs 20:16:10 Integrated Voltage Measurement... 20:16:19 Voltage Offset Correction: v_off_ini = 3141.509 uV, v_off_fin = 3123.106 uV 20:16:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.534 uVs 20:16:19 Integrated Voltage Measurement... 20:16:28 Voltage Offset Correction: v_off_ini = 3126.104 uV, v_off_fin = 3160.077 uV 20:16:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.235 uVs 20:16:32 I1Y Average and RMS of Measurements VT = -196.830 +- 6.945 uVs I1Y = -39.366 +- 1.389 uTm 20:16:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:16:37 Integrated Voltage Measurement... 20:16:46 Voltage Offset Correction: v_off_ini = 3141.960 uV, v_off_fin = 3136.053 uV 20:16:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.376 uVs 20:16:46 Integrated Voltage Measurement... 20:16:55 Voltage Offset Correction: v_off_ini = 3122.588 uV, v_off_fin = 3120.538 uV 20:16:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.518 uVs 20:16:55 Integrated Voltage Measurement... 20:17:04 Voltage Offset Correction: v_off_ini = 3145.399 uV, v_off_fin = 3116.604 uV 20:17:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.809 uVs 20:17:04 Integrated Voltage Measurement... 20:17:13 Voltage Offset Correction: v_off_ini = 3120.899 uV, v_off_fin = 3157.008 uV 20:17:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.931 uVs 20:17:13 Integrated Voltage Measurement... 20:17:22 Voltage Offset Correction: v_off_ini = 3149.075 uV, v_off_fin = 3109.662 uV 20:17:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.248 uVs 20:17:22 Integrated Voltage Measurement... 20:17:31 Voltage Offset Correction: v_off_ini = 3133.955 uV, v_off_fin = 3148.356 uV 20:17:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.442 uVs 20:17:34 I2X Average and RMS of Measurements VT = -33.221 +- 14.971 uVs I2X = 3.056 +- 1.377 uTm^2 20:17:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:17:39 Integrated Voltage Measurement... 20:17:48 Voltage Offset Correction: v_off_ini = 3141.238 uV, v_off_fin = 3140.078 uV 20:17:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.653 uVs 20:17:48 Integrated Voltage Measurement... 20:17:57 Voltage Offset Correction: v_off_ini = 3145.225 uV, v_off_fin = 3124.090 uV 20:17:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.621 uVs 20:17:57 Integrated Voltage Measurement... 20:18:06 Voltage Offset Correction: v_off_ini = 3146.643 uV, v_off_fin = 3135.655 uV 20:18:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.321 uVs 20:18:06 Integrated Voltage Measurement... 20:18:15 Voltage Offset Correction: v_off_ini = 3107.809 uV, v_off_fin = 3122.320 uV 20:18:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.490 uVs 20:18:15 Integrated Voltage Measurement... 20:18:24 Voltage Offset Correction: v_off_ini = 3115.443 uV, v_off_fin = 3115.404 uV 20:18:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.591 uVs 20:18:24 Integrated Voltage Measurement... 20:18:33 Voltage Offset Correction: v_off_ini = 3110.716 uV, v_off_fin = 3113.122 uV 20:18:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.329 uVs 20:18:35 I2Y Average and RMS of Measurements VT = -246.834 +- 3.741 uVs I2Y = -22.709 +- 0.344 uTm^2 20:18:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:18:44 Integrated Voltage Measurement... 20:18:53 Voltage Offset Correction: v_off_ini = 3108.066 uV, v_off_fin = 3084.908 uV 20:18:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.940 uVs 20:18:53 Integrated Voltage Measurement... 20:19:02 Voltage Offset Correction: v_off_ini = 3097.390 uV, v_off_fin = 3110.201 uV 20:19:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.625 uVs 20:19:02 Integrated Voltage Measurement... 20:19:11 Voltage Offset Correction: v_off_ini = 3104.529 uV, v_off_fin = 3108.136 uV 20:19:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.383 uVs 20:19:11 Integrated Voltage Measurement... 20:19:20 Voltage Offset Correction: v_off_ini = 3117.654 uV, v_off_fin = 3117.738 uV 20:19:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 44.195 uVs 20:19:20 Integrated Voltage Measurement... 20:19:29 Voltage Offset Correction: v_off_ini = 3102.766 uV, v_off_fin = 3106.725 uV 20:19:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.453 uVs 20:19:29 Integrated Voltage Measurement... 20:19:38 Voltage Offset Correction: v_off_ini = 3132.818 uV, v_off_fin = 3097.180 uV 20:19:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.926 uVs 20:19:42 I1X Average and RMS of Measurements VT = -52.920 +- 2.615 uVs I1X = 10.584 +- 0.523 uTm 20:19:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:19:49 Integrated Voltage Measurement... 20:19:58 Voltage Offset Correction: v_off_ini = 3076.147 uV, v_off_fin = 3071.291 uV 20:19:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.984 uVs 20:19:58 Integrated Voltage Measurement... 20:20:07 Voltage Offset Correction: v_off_ini = 3069.895 uV, v_off_fin = 3071.510 uV 20:20:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.326 uVs 20:20:07 Integrated Voltage Measurement... 20:20:16 Voltage Offset Correction: v_off_ini = 3064.763 uV, v_off_fin = 3060.712 uV 20:20:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.090 uVs 20:20:16 Integrated Voltage Measurement... 20:20:25 Voltage Offset Correction: v_off_ini = 3041.066 uV, v_off_fin = 3075.975 uV 20:20:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.402 uVs 20:20:25 Integrated Voltage Measurement... 20:20:34 Voltage Offset Correction: v_off_ini = 3056.354 uV, v_off_fin = 3062.402 uV 20:20:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.387 uVs 20:20:34 Integrated Voltage Measurement... 20:20:43 Voltage Offset Correction: v_off_ini = 3061.437 uV, v_off_fin = 3083.503 uV 20:20:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.610 uVs 20:20:47 I1Y Average and RMS of Measurements VT = -205.966 +- 17.212 uVs I1Y = -41.192 +- 3.443 uTm 20:20:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:20:52 Integrated Voltage Measurement... 20:21:01 Voltage Offset Correction: v_off_ini = 3089.832 uV, v_off_fin = 3065.933 uV 20:21:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.830 uVs 20:21:01 Integrated Voltage Measurement... 20:21:10 Voltage Offset Correction: v_off_ini = 3085.944 uV, v_off_fin = 3074.734 uV 20:21:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.270 uVs 20:21:10 Integrated Voltage Measurement... 20:21:19 Voltage Offset Correction: v_off_ini = 3087.989 uV, v_off_fin = 3080.381 uV 20:21:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.281 uVs 20:21:19 Integrated Voltage Measurement... 20:21:28 Voltage Offset Correction: v_off_ini = 3100.484 uV, v_off_fin = 3108.651 uV 20:21:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.740 uVs 20:21:28 Integrated Voltage Measurement... 20:21:37 Voltage Offset Correction: v_off_ini = 3085.238 uV, v_off_fin = 3075.659 uV 20:21:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.373 uVs 20:21:37 Integrated Voltage Measurement... 20:21:46 Voltage Offset Correction: v_off_ini = 3081.925 uV, v_off_fin = 3114.714 uV 20:21:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.186 uVs 20:21:49 I2X Average and RMS of Measurements VT = -55.447 +- 11.752 uVs I2X = 5.101 +- 1.081 uTm^2 20:21:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:21:54 Integrated Voltage Measurement... 20:22:03 Voltage Offset Correction: v_off_ini = 3091.207 uV, v_off_fin = 3071.332 uV 20:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.550 uVs 20:22:03 Integrated Voltage Measurement... 20:22:12 Voltage Offset Correction: v_off_ini = 3111.438 uV, v_off_fin = 3078.518 uV 20:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.363 uVs 20:22:12 Integrated Voltage Measurement... 20:22:21 Voltage Offset Correction: v_off_ini = 3096.566 uV, v_off_fin = 3109.040 uV 20:22:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.765 uVs 20:22:21 Integrated Voltage Measurement... 20:22:30 Voltage Offset Correction: v_off_ini = 3093.824 uV, v_off_fin = 3096.288 uV 20:22:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.251 uVs 20:22:30 Integrated Voltage Measurement... 20:22:39 Voltage Offset Correction: v_off_ini = 3110.725 uV, v_off_fin = 3115.315 uV 20:22:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.539 uVs 20:22:39 Integrated Voltage Measurement... 20:22:48 Voltage Offset Correction: v_off_ini = 3117.212 uV, v_off_fin = 3114.717 uV 20:22:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.861 uVs 20:22:50 I2Y Average and RMS of Measurements VT = -241.222 +- 7.157 uVs I2Y = -22.192 +- 0.658 uTm^2 20:22:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:22:58 Integrated Voltage Measurement... 20:23:07 Voltage Offset Correction: v_off_ini = 3143.457 uV, v_off_fin = 3117.701 uV 20:23:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -55.972 uVs 20:23:08 Integrated Voltage Measurement... 20:23:16 Voltage Offset Correction: v_off_ini = 3107.180 uV, v_off_fin = 3122.265 uV 20:23:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.145 uVs 20:23:17 Integrated Voltage Measurement... 20:23:25 Voltage Offset Correction: v_off_ini = 3116.098 uV, v_off_fin = 3103.953 uV 20:23:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.922 uVs 20:23:26 Integrated Voltage Measurement... 20:23:34 Voltage Offset Correction: v_off_ini = 3100.243 uV, v_off_fin = 3106.273 uV 20:23:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 40.507 uVs 20:23:35 Integrated Voltage Measurement... 20:23:43 Voltage Offset Correction: v_off_ini = 3083.499 uV, v_off_fin = 3095.416 uV 20:23:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -2.689 uVs 20:23:44 Integrated Voltage Measurement... 20:23:53 Voltage Offset Correction: v_off_ini = 3096.693 uV, v_off_fin = 3076.877 uV 20:23:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.125 uVs 20:23:57 I1X Average and RMS of Measurements VT = -30.727 +- 13.243 uVs I1X = 6.146 +- 2.649 uTm 20:23:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:24:03 Integrated Voltage Measurement... 20:24:12 Voltage Offset Correction: v_off_ini = 3061.876 uV, v_off_fin = 3077.270 uV 20:24:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -175.050 uVs 20:24:12 Integrated Voltage Measurement... 20:24:21 Voltage Offset Correction: v_off_ini = 3079.734 uV, v_off_fin = 3119.269 uV 20:24:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.441 uVs 20:24:21 Integrated Voltage Measurement... 20:24:30 Voltage Offset Correction: v_off_ini = 3096.892 uV, v_off_fin = 3087.188 uV 20:24:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.642 uVs 20:24:30 Integrated Voltage Measurement... 20:24:39 Voltage Offset Correction: v_off_ini = 3067.414 uV, v_off_fin = 3086.040 uV 20:24:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.380 uVs 20:24:39 Integrated Voltage Measurement... 20:24:48 Voltage Offset Correction: v_off_ini = 3081.111 uV, v_off_fin = 3081.553 uV 20:24:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.291 uVs 20:24:48 Integrated Voltage Measurement... 20:24:57 Voltage Offset Correction: v_off_ini = 3078.904 uV, v_off_fin = 3093.998 uV 20:24:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.259 uVs 20:25:02 I1Y Average and RMS of Measurements VT = -190.511 +- 8.603 uVs I1Y = -38.100 +- 1.720 uTm 20:25:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:25:07 Integrated Voltage Measurement... 20:25:16 Voltage Offset Correction: v_off_ini = 3068.814 uV, v_off_fin = 3078.641 uV 20:25:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.693 uVs 20:25:16 Integrated Voltage Measurement... 20:25:25 Voltage Offset Correction: v_off_ini = 3091.119 uV, v_off_fin = 3098.724 uV 20:25:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.059 uVs 20:25:25 Integrated Voltage Measurement... 20:25:34 Voltage Offset Correction: v_off_ini = 3078.131 uV, v_off_fin = 3051.865 uV 20:25:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.262 uVs 20:25:34 Integrated Voltage Measurement... 20:25:43 Voltage Offset Correction: v_off_ini = 3097.713 uV, v_off_fin = 3093.307 uV 20:25:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.637 uVs 20:25:43 Integrated Voltage Measurement... 20:25:52 Voltage Offset Correction: v_off_ini = 3105.390 uV, v_off_fin = 3081.468 uV 20:25:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.892 uVs 20:25:52 Integrated Voltage Measurement... 20:26:01 Voltage Offset Correction: v_off_ini = 3099.581 uV, v_off_fin = 3094.882 uV 20:26:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.799 uVs 20:26:03 I2X Average and RMS of Measurements VT = -40.390 +- 12.256 uVs I2X = 3.716 +- 1.128 uTm^2 20:26:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:26:08 Integrated Voltage Measurement... 20:26:17 Voltage Offset Correction: v_off_ini = 3063.920 uV, v_off_fin = 3076.388 uV 20:26:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.627 uVs 20:26:17 Integrated Voltage Measurement... 20:26:26 Voltage Offset Correction: v_off_ini = 3066.958 uV, v_off_fin = 3061.626 uV 20:26:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.500 uVs 20:26:26 Integrated Voltage Measurement... 20:26:35 Voltage Offset Correction: v_off_ini = 3057.245 uV, v_off_fin = 3054.180 uV 20:26:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.416 uVs 20:26:35 Integrated Voltage Measurement... 20:26:44 Voltage Offset Correction: v_off_ini = 3088.703 uV, v_off_fin = 3059.059 uV 20:26:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.758 uVs 20:26:44 Integrated Voltage Measurement... 20:26:53 Voltage Offset Correction: v_off_ini = 3029.176 uV, v_off_fin = 3059.841 uV 20:26:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.018 uVs 20:26:53 Integrated Voltage Measurement... 20:27:02 Voltage Offset Correction: v_off_ini = 3052.713 uV, v_off_fin = 3046.568 uV 20:27:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.789 uVs 20:27:05 I2Y Average and RMS of Measurements VT = -243.352 +- 12.188 uVs I2Y = -22.388 +- 1.121 uTm^2 20:27:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:27:13 Integrated Voltage Measurement... 20:27:22 Voltage Offset Correction: v_off_ini = 3069.156 uV, v_off_fin = 3044.408 uV 20:27:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -46.204 uVs 20:27:22 Integrated Voltage Measurement... 20:27:31 Voltage Offset Correction: v_off_ini = 3043.483 uV, v_off_fin = 3038.760 uV 20:27:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.372 uVs 20:27:31 Integrated Voltage Measurement... 20:27:40 Voltage Offset Correction: v_off_ini = 3057.194 uV, v_off_fin = 3047.914 uV 20:27:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.434 uVs 20:27:40 Integrated Voltage Measurement... 20:27:49 Voltage Offset Correction: v_off_ini = 3027.645 uV, v_off_fin = 3040.360 uV 20:27:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.707 uVs 20:27:49 Integrated Voltage Measurement... 20:27:58 Voltage Offset Correction: v_off_ini = 3048.726 uV, v_off_fin = 3050.791 uV 20:27:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.741 uVs 20:27:58 Integrated Voltage Measurement... 20:28:07 Voltage Offset Correction: v_off_ini = 3032.379 uV, v_off_fin = 3048.452 uV 20:28:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 6.382 uVs 20:28:11 I1X Average and RMS of Measurements VT = -35.807 +- 15.960 uVs I1X = 7.162 +- 3.192 uTm 20:28:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:28:18 Integrated Voltage Measurement... 20:28:27 Voltage Offset Correction: v_off_ini = 3038.813 uV, v_off_fin = 3053.403 uV 20:28:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.471 uVs 20:28:27 Integrated Voltage Measurement... 20:28:36 Voltage Offset Correction: v_off_ini = 3062.148 uV, v_off_fin = 3067.032 uV 20:28:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.980 uVs 20:28:36 Integrated Voltage Measurement... 20:28:45 Voltage Offset Correction: v_off_ini = 3023.745 uV, v_off_fin = 3022.748 uV 20:28:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.425 uVs 20:28:45 Integrated Voltage Measurement... 20:28:54 Voltage Offset Correction: v_off_ini = 3068.342 uV, v_off_fin = 3076.517 uV 20:28:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.537 uVs 20:28:54 Integrated Voltage Measurement... 20:29:03 Voltage Offset Correction: v_off_ini = 3053.524 uV, v_off_fin = 3030.609 uV 20:29:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.474 uVs 20:29:03 Integrated Voltage Measurement... 20:29:12 Voltage Offset Correction: v_off_ini = 3023.817 uV, v_off_fin = 3003.411 uV 20:29:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.748 uVs 20:29:16 I1Y Average and RMS of Measurements VT = -191.106 +- 7.414 uVs I1Y = -38.219 +- 1.481 uTm 20:29:19 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:29:21 Integrated Voltage Measurement... 20:29:30 Voltage Offset Correction: v_off_ini = 3008.290 uV, v_off_fin = 3000.611 uV 20:29:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.113 uVs 20:29:30 Integrated Voltage Measurement... 20:29:39 Voltage Offset Correction: v_off_ini = 2995.479 uV, v_off_fin = 2993.815 uV 20:29:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.288 uVs 20:29:39 Integrated Voltage Measurement... 20:29:48 Voltage Offset Correction: v_off_ini = 2992.488 uV, v_off_fin = 2980.750 uV 20:29:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.482 uVs 20:29:48 Integrated Voltage Measurement... 20:29:57 Voltage Offset Correction: v_off_ini = 3002.825 uV, v_off_fin = 3012.736 uV 20:29:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -0.592 uVs 20:29:58 Integrated Voltage Measurement... 20:30:07 Voltage Offset Correction: v_off_ini = 3005.560 uV, v_off_fin = 2987.483 uV 20:30:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.715 uVs 20:30:07 Integrated Voltage Measurement... 20:30:16 Voltage Offset Correction: v_off_ini = 2986.844 uV, v_off_fin = 3039.153 uV 20:30:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.345 uVs 20:30:18 I2X Average and RMS of Measurements VT = -35.725 +- 12.614 uVs I2X = 3.287 +- 1.160 uTm^2 20:30:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:30:23 Integrated Voltage Measurement... 20:30:32 Voltage Offset Correction: v_off_ini = 2998.986 uV, v_off_fin = 3000.603 uV 20:30:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.273 uVs 20:30:32 Integrated Voltage Measurement... 20:30:41 Voltage Offset Correction: v_off_ini = 3001.783 uV, v_off_fin = 3003.250 uV 20:30:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.822 uVs 20:30:41 Integrated Voltage Measurement... 20:30:50 Voltage Offset Correction: v_off_ini = 2971.536 uV, v_off_fin = 3009.896 uV 20:30:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.900 uVs 20:30:50 Integrated Voltage Measurement... 20:30:59 Voltage Offset Correction: v_off_ini = 3005.901 uV, v_off_fin = 2989.824 uV 20:30:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.249 uVs 20:30:59 Integrated Voltage Measurement... 20:31:08 Voltage Offset Correction: v_off_ini = 2994.116 uV, v_off_fin = 3007.231 uV 20:31:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.023 uVs 20:31:08 Integrated Voltage Measurement... 20:31:17 Voltage Offset Correction: v_off_ini = 2982.326 uV, v_off_fin = 2980.794 uV 20:31:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.759 uVs 20:31:20 I2Y Average and RMS of Measurements VT = -240.671 +- 17.278 uVs I2Y = -22.142 +- 1.590 uTm^2 20:31:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm