SLAC Magnetic Measurements Date: 07-16-2025 Time: 13:47:19 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_15081 Dataset Number: 3 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 1 Measurement Device: Operator: YL Comment: On Axis 13:48:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:20 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:48:22 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:48:23 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:48:25 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:50:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:50:14 Integrated Voltage Measurement... 13:50:23 Voltage Offset Correction: v_off_ini = 639.697 uV, v_off_fin = 628.535 uV 13:50:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.196 uVs 13:50:23 Integrated Voltage Measurement... 13:50:32 Voltage Offset Correction: v_off_ini = 628.504 uV, v_off_fin = 625.526 uV 13:50:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.862 uVs 13:50:32 Integrated Voltage Measurement... 13:50:41 Voltage Offset Correction: v_off_ini = 630.097 uV, v_off_fin = 622.295 uV 13:50:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.797 uVs 13:50:41 Integrated Voltage Measurement... 13:50:50 Voltage Offset Correction: v_off_ini = 621.657 uV, v_off_fin = 616.505 uV 13:50:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.135 uVs 13:50:50 Integrated Voltage Measurement... 13:50:59 Voltage Offset Correction: v_off_ini = 614.169 uV, v_off_fin = 623.005 uV 13:50:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.860 uVs 13:50:59 Integrated Voltage Measurement... 13:51:08 Voltage Offset Correction: v_off_ini = 631.578 uV, v_off_fin = 626.806 uV 13:51:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.022 uVs 13:51:12 I1X Average and RMS of Measurements VT = -83.812 +- 2.780 uVs I1X = 16.763 +- 0.556 uTm 13:51:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:19 Integrated Voltage Measurement... 13:51:28 Voltage Offset Correction: v_off_ini = 627.822 uV, v_off_fin = 619.148 uV 13:51:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -302.361 uVs 13:51:28 Integrated Voltage Measurement... 13:51:37 Voltage Offset Correction: v_off_ini = 626.308 uV, v_off_fin = 642.466 uV 13:51:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 303.402 uVs 13:51:37 Integrated Voltage Measurement... 13:51:46 Voltage Offset Correction: v_off_ini = 623.278 uV, v_off_fin = 617.536 uV 13:51:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -296.451 uVs 13:51:46 Integrated Voltage Measurement... 13:51:55 Voltage Offset Correction: v_off_ini = 624.273 uV, v_off_fin = 646.755 uV 13:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 308.169 uVs 13:51:55 Integrated Voltage Measurement... 13:52:04 Voltage Offset Correction: v_off_ini = 625.380 uV, v_off_fin = 613.076 uV 13:52:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -297.292 uVs 13:52:04 Integrated Voltage Measurement... 13:52:13 Voltage Offset Correction: v_off_ini = 622.113 uV, v_off_fin = 638.915 uV 13:52:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 292.248 uVs 13:52:17 I1Y Average and RMS of Measurements VT = -299.987 +- 3.696 uVs I1Y = -59.998 +- 0.738 uTm 13:52:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:25 Integrated Voltage Measurement... 13:52:34 Voltage Offset Correction: v_off_ini = 619.010 uV, v_off_fin = 624.651 uV 13:52:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.808 uVs 13:52:34 Integrated Voltage Measurement... 13:52:43 Voltage Offset Correction: v_off_ini = 639.589 uV, v_off_fin = 643.024 uV 13:52:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.956 uVs 13:52:43 Integrated Voltage Measurement... 13:52:52 Voltage Offset Correction: v_off_ini = 630.274 uV, v_off_fin = 613.361 uV 13:52:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.748 uVs 13:52:52 Integrated Voltage Measurement... 13:53:01 Voltage Offset Correction: v_off_ini = 619.681 uV, v_off_fin = 629.983 uV 13:53:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.104 uVs 13:53:01 Integrated Voltage Measurement... 13:53:10 Voltage Offset Correction: v_off_ini = 626.453 uV, v_off_fin = 615.857 uV 13:53:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.166 uVs 13:53:10 Integrated Voltage Measurement... 13:53:19 Voltage Offset Correction: v_off_ini = 623.822 uV, v_off_fin = 628.879 uV 13:53:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.712 uVs 13:53:22 I2X Average and RMS of Measurements VT = -46.582 +- 3.489 uVs I2X = 4.286 +- 0.321 uTm^2 13:53:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:29 Integrated Voltage Measurement... 13:53:38 Voltage Offset Correction: v_off_ini = 611.105 uV, v_off_fin = 614.606 uV 13:53:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.169 uVs 13:53:38 Integrated Voltage Measurement... 13:53:47 Voltage Offset Correction: v_off_ini = 612.082 uV, v_off_fin = 614.683 uV 13:53:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.224 uVs 13:53:48 Integrated Voltage Measurement... 13:53:57 Voltage Offset Correction: v_off_ini = 602.233 uV, v_off_fin = 610.529 uV 13:53:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.246 uVs 13:53:57 Integrated Voltage Measurement... 13:54:06 Voltage Offset Correction: v_off_ini = 606.549 uV, v_off_fin = 604.249 uV 13:54:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.509 uVs 13:54:06 Integrated Voltage Measurement... 13:54:15 Voltage Offset Correction: v_off_ini = 599.505 uV, v_off_fin = 609.201 uV 13:54:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.153 uVs 13:54:15 Integrated Voltage Measurement... 13:54:24 Voltage Offset Correction: v_off_ini = 614.497 uV, v_off_fin = 605.931 uV 13:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.122 uVs 13:54:26 I2Y Average and RMS of Measurements VT = -298.404 +- 3.611 uVs I2Y = -27.453 +- 0.332 uTm^2 13:54:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:41 Integrated Voltage Measurement... 13:54:50 Voltage Offset Correction: v_off_ini = 601.467 uV, v_off_fin = 599.902 uV 13:54:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -76.248 uVs 13:54:50 Integrated Voltage Measurement... 13:54:59 Voltage Offset Correction: v_off_ini = 602.028 uV, v_off_fin = 607.810 uV 13:54:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.336 uVs 13:54:59 Integrated Voltage Measurement... 13:55:08 Voltage Offset Correction: v_off_ini = 596.043 uV, v_off_fin = 611.135 uV 13:55:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.074 uVs 13:55:08 Integrated Voltage Measurement... 13:55:17 Voltage Offset Correction: v_off_ini = 610.010 uV, v_off_fin = 608.618 uV 13:55:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.419 uVs 13:55:17 Integrated Voltage Measurement... 13:55:26 Voltage Offset Correction: v_off_ini = 615.481 uV, v_off_fin = 605.514 uV 13:55:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.786 uVs 13:55:26 Integrated Voltage Measurement... 13:55:35 Voltage Offset Correction: v_off_ini = 603.135 uV, v_off_fin = 606.622 uV 13:55:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.370 uVs 13:55:39 I1X Average and RMS of Measurements VT = -72.706 +- 3.657 uVs I1X = 14.542 +- 0.730 uTm 13:55:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:46 Integrated Voltage Measurement... 13:55:55 Voltage Offset Correction: v_off_ini = 602.998 uV, v_off_fin = 586.285 uV 13:55:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.883 uVs 13:55:55 Integrated Voltage Measurement... 13:56:04 Voltage Offset Correction: v_off_ini = 598.902 uV, v_off_fin = 607.187 uV 13:56:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 275.572 uVs 13:56:04 Integrated Voltage Measurement... 13:56:13 Voltage Offset Correction: v_off_ini = 593.031 uV, v_off_fin = 585.249 uV 13:56:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -298.626 uVs 13:56:13 Integrated Voltage Measurement... 13:56:22 Voltage Offset Correction: v_off_ini = 602.564 uV, v_off_fin = 611.192 uV 13:56:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 297.385 uVs 13:56:22 Integrated Voltage Measurement... 13:56:31 Voltage Offset Correction: v_off_ini = 610.639 uV, v_off_fin = 594.553 uV 13:56:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -303.047 uVs 13:56:31 Integrated Voltage Measurement... 13:56:40 Voltage Offset Correction: v_off_ini = 606.314 uV, v_off_fin = 612.732 uV 13:56:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 291.743 uVs 13:56:45 I1Y Average and RMS of Measurements VT = -291.543 +- 8.712 uVs I1Y = -58.309 +- 1.742 uTm 13:56:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:52 Integrated Voltage Measurement... 13:57:01 Voltage Offset Correction: v_off_ini = 608.249 uV, v_off_fin = 592.600 uV 13:57:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -41.241 uVs 13:57:01 Integrated Voltage Measurement... 13:57:10 Voltage Offset Correction: v_off_ini = 588.449 uV, v_off_fin = 600.130 uV 13:57:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.711 uVs 13:57:10 Integrated Voltage Measurement... 13:57:19 Voltage Offset Correction: v_off_ini = 606.155 uV, v_off_fin = 583.332 uV 13:57:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.910 uVs 13:57:19 Integrated Voltage Measurement... 13:57:28 Voltage Offset Correction: v_off_ini = 604.351 uV, v_off_fin = 609.522 uV 13:57:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.204 uVs 13:57:28 Integrated Voltage Measurement... 13:57:37 Voltage Offset Correction: v_off_ini = 589.835 uV, v_off_fin = 602.181 uV 13:57:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.837 uVs 13:57:37 Integrated Voltage Measurement... 13:57:46 Voltage Offset Correction: v_off_ini = 606.028 uV, v_off_fin = 604.408 uV 13:57:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.429 uVs 13:57:49 I2X Average and RMS of Measurements VT = -50.222 +- 0.898 uVs I2X = 4.620 +- 0.083 uTm^2 13:57:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:57 Integrated Voltage Measurement... 13:58:06 Voltage Offset Correction: v_off_ini = 578.711 uV, v_off_fin = 582.044 uV 13:58:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.921 uVs 13:58:06 Integrated Voltage Measurement... 13:58:15 Voltage Offset Correction: v_off_ini = 581.688 uV, v_off_fin = 577.786 uV 13:58:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.227 uVs 13:58:15 Integrated Voltage Measurement... 13:58:24 Voltage Offset Correction: v_off_ini = 580.549 uV, v_off_fin = 573.993 uV 13:58:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.783 uVs 13:58:24 Integrated Voltage Measurement... 13:58:33 Voltage Offset Correction: v_off_ini = 578.893 uV, v_off_fin = 582.823 uV 13:58:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.137 uVs 13:58:33 Integrated Voltage Measurement... 13:58:42 Voltage Offset Correction: v_off_ini = 573.930 uV, v_off_fin = 580.053 uV 13:58:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.911 uVs 13:58:42 Integrated Voltage Measurement... 13:58:51 Voltage Offset Correction: v_off_ini = 581.654 uV, v_off_fin = 584.326 uV 13:58:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.201 uVs 13:58:53 I2Y Average and RMS of Measurements VT = -292.864 +- 1.660 uVs I2Y = -26.943 +- 0.153 uTm^2 13:59:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:59:08 Integrated Voltage Measurement... 13:59:17 Voltage Offset Correction: v_off_ini = 582.372 uV, v_off_fin = 575.720 uV 13:59:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.856 uVs 13:59:17 Integrated Voltage Measurement... 13:59:26 Voltage Offset Correction: v_off_ini = 574.012 uV, v_off_fin = 578.758 uV 13:59:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 59.217 uVs 13:59:26 Integrated Voltage Measurement... 13:59:35 Voltage Offset Correction: v_off_ini = 579.177 uV, v_off_fin = 582.119 uV 13:59:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.004 uVs 13:59:35 Integrated Voltage Measurement... 13:59:44 Voltage Offset Correction: v_off_ini = 580.604 uV, v_off_fin = 576.639 uV 13:59:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.832 uVs 13:59:44 Integrated Voltage Measurement... 13:59:53 Voltage Offset Correction: v_off_ini = 561.210 uV, v_off_fin = 574.287 uV 13:59:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.464 uVs 13:59:53 Integrated Voltage Measurement... 14:00:02 Voltage Offset Correction: v_off_ini = 585.271 uV, v_off_fin = 578.982 uV 14:00:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.611 uVs 14:00:07 I1X Average and RMS of Measurements VT = -56.497 +- 3.222 uVs I1X = 11.300 +- 0.645 uTm 14:00:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:13 Integrated Voltage Measurement... 14:00:22 Voltage Offset Correction: v_off_ini = 562.728 uV, v_off_fin = 558.779 uV 14:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.192 uVs 14:00:22 Integrated Voltage Measurement... 14:00:31 Voltage Offset Correction: v_off_ini = 565.186 uV, v_off_fin = 580.271 uV 14:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 294.314 uVs 14:00:31 Integrated Voltage Measurement... 14:00:40 Voltage Offset Correction: v_off_ini = 572.501 uV, v_off_fin = 556.027 uV 14:00:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -276.948 uVs 14:00:40 Integrated Voltage Measurement... 14:00:49 Voltage Offset Correction: v_off_ini = 564.863 uV, v_off_fin = 579.933 uV 14:00:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.764 uVs 14:00:49 Integrated Voltage Measurement... 14:00:58 Voltage Offset Correction: v_off_ini = 566.687 uV, v_off_fin = 550.125 uV 14:00:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.523 uVs 14:00:58 Integrated Voltage Measurement... 14:01:07 Voltage Offset Correction: v_off_ini = 545.190 uV, v_off_fin = 571.882 uV 14:01:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 286.415 uVs 14:01:12 I1Y Average and RMS of Measurements VT = -282.359 +- 2.331 uVs I1Y = -56.472 +- 0.466 uTm 14:01:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:19 Integrated Voltage Measurement... 14:01:28 Voltage Offset Correction: v_off_ini = 552.736 uV, v_off_fin = 565.317 uV 14:01:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.034 uVs 14:01:28 Integrated Voltage Measurement... 14:01:37 Voltage Offset Correction: v_off_ini = 567.820 uV, v_off_fin = 569.790 uV 14:01:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.428 uVs 14:01:37 Integrated Voltage Measurement... 14:01:46 Voltage Offset Correction: v_off_ini = 565.663 uV, v_off_fin = 574.824 uV 14:01:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.381 uVs 14:01:46 Integrated Voltage Measurement... 14:01:55 Voltage Offset Correction: v_off_ini = 578.375 uV, v_off_fin = 584.869 uV 14:01:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.206 uVs 14:01:55 Integrated Voltage Measurement... 14:02:04 Voltage Offset Correction: v_off_ini = 568.687 uV, v_off_fin = 568.329 uV 14:02:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.865 uVs 14:02:05 Integrated Voltage Measurement... 14:02:14 Voltage Offset Correction: v_off_ini = 577.212 uV, v_off_fin = 583.958 uV 14:02:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.931 uVs 14:02:16 I2X Average and RMS of Measurements VT = -38.141 +- 2.085 uVs I2X = 3.509 +- 0.192 uTm^2 14:02:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:24 Integrated Voltage Measurement... 14:02:33 Voltage Offset Correction: v_off_ini = 585.429 uV, v_off_fin = 575.555 uV 14:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.821 uVs 14:02:33 Integrated Voltage Measurement... 14:02:42 Voltage Offset Correction: v_off_ini = 581.645 uV, v_off_fin = 583.707 uV 14:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.862 uVs 14:02:42 Integrated Voltage Measurement... 14:02:51 Voltage Offset Correction: v_off_ini = 587.906 uV, v_off_fin = 585.739 uV 14:02:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.822 uVs 14:02:51 Integrated Voltage Measurement... 14:03:00 Voltage Offset Correction: v_off_ini = 590.539 uV, v_off_fin = 585.535 uV 14:03:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.786 uVs 14:03:00 Integrated Voltage Measurement... 14:03:09 Voltage Offset Correction: v_off_ini = 581.994 uV, v_off_fin = 578.071 uV 14:03:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.856 uVs 14:03:09 Integrated Voltage Measurement... 14:03:18 Voltage Offset Correction: v_off_ini = 595.319 uV, v_off_fin = 588.158 uV 14:03:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.080 uVs 14:03:20 I2Y Average and RMS of Measurements VT = -282.204 +- 5.421 uVs I2Y = -25.963 +- 0.499 uTm^2 14:03:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:03:35 Integrated Voltage Measurement... 14:03:44 Voltage Offset Correction: v_off_ini = 566.047 uV, v_off_fin = 564.676 uV 14:03:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.494 uVs 14:03:44 Integrated Voltage Measurement... 14:03:53 Voltage Offset Correction: v_off_ini = 572.525 uV, v_off_fin = 581.269 uV 14:03:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.867 uVs 14:03:53 Integrated Voltage Measurement... 14:04:02 Voltage Offset Correction: v_off_ini = 575.852 uV, v_off_fin = 560.173 uV 14:04:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.755 uVs 14:04:02 Integrated Voltage Measurement... 14:04:11 Voltage Offset Correction: v_off_ini = 572.822 uV, v_off_fin = 577.526 uV 14:04:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.453 uVs 14:04:11 Integrated Voltage Measurement... 14:04:20 Voltage Offset Correction: v_off_ini = 574.351 uV, v_off_fin = 563.830 uV 14:04:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.338 uVs 14:04:20 Integrated Voltage Measurement... 14:04:29 Voltage Offset Correction: v_off_ini = 570.178 uV, v_off_fin = 561.960 uV 14:04:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.076 uVs 14:04:34 I1X Average and RMS of Measurements VT = -54.330 +- 0.442 uVs I1X = 10.866 +- 0.088 uTm 14:04:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:40 Integrated Voltage Measurement... 14:04:49 Voltage Offset Correction: v_off_ini = 562.008 uV, v_off_fin = 553.425 uV 14:04:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.772 uVs 14:04:49 Integrated Voltage Measurement... 14:04:58 Voltage Offset Correction: v_off_ini = 561.812 uV, v_off_fin = 577.485 uV 14:04:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 290.382 uVs 14:04:58 Integrated Voltage Measurement... 14:05:07 Voltage Offset Correction: v_off_ini = 564.197 uV, v_off_fin = 556.787 uV 14:05:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -271.886 uVs 14:05:07 Integrated Voltage Measurement... 14:05:16 Voltage Offset Correction: v_off_ini = 560.705 uV, v_off_fin = 570.673 uV 14:05:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 268.648 uVs 14:05:16 Integrated Voltage Measurement... 14:05:25 Voltage Offset Correction: v_off_ini = 559.014 uV, v_off_fin = 549.458 uV 14:05:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.184 uVs 14:05:25 Integrated Voltage Measurement... 14:05:34 Voltage Offset Correction: v_off_ini = 561.126 uV, v_off_fin = 566.842 uV 14:05:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 285.546 uVs 14:05:39 I1Y Average and RMS of Measurements VT = -275.403 +- 3.861 uVs I1Y = -55.077 +- 0.773 uTm 14:05:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:46 Integrated Voltage Measurement... 14:05:55 Voltage Offset Correction: v_off_ini = 573.288 uV, v_off_fin = 559.676 uV 14:05:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.611 uVs 14:05:55 Integrated Voltage Measurement... 14:06:04 Voltage Offset Correction: v_off_ini = 558.081 uV, v_off_fin = 564.497 uV 14:06:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.144 uVs 14:06:04 Integrated Voltage Measurement... 14:06:13 Voltage Offset Correction: v_off_ini = 569.007 uV, v_off_fin = 562.770 uV 14:06:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.957 uVs 14:06:14 Integrated Voltage Measurement... 14:06:22 Voltage Offset Correction: v_off_ini = 566.419 uV, v_off_fin = 576.729 uV 14:06:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.891 uVs 14:06:23 Integrated Voltage Measurement... 14:06:32 Voltage Offset Correction: v_off_ini = 587.002 uV, v_off_fin = 568.836 uV 14:06:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.728 uVs 14:06:32 Integrated Voltage Measurement... 14:06:41 Voltage Offset Correction: v_off_ini = 580.244 uV, v_off_fin = 577.448 uV 14:06:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.596 uVs 14:06:43 I2X Average and RMS of Measurements VT = -40.655 +- 6.014 uVs I2X = 3.740 +- 0.553 uTm^2 14:06:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:51 Integrated Voltage Measurement... 14:07:00 Voltage Offset Correction: v_off_ini = 578.407 uV, v_off_fin = 572.413 uV 14:07:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.258 uVs 14:07:00 Integrated Voltage Measurement... 14:07:09 Voltage Offset Correction: v_off_ini = 571.837 uV, v_off_fin = 570.593 uV 14:07:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.965 uVs 14:07:09 Integrated Voltage Measurement... 14:07:18 Voltage Offset Correction: v_off_ini = 585.530 uV, v_off_fin = 572.384 uV 14:07:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.406 uVs 14:07:18 Integrated Voltage Measurement... 14:07:27 Voltage Offset Correction: v_off_ini = 575.123 uV, v_off_fin = 570.672 uV 14:07:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.585 uVs 14:07:27 Integrated Voltage Measurement... 14:07:36 Voltage Offset Correction: v_off_ini = 578.808 uV, v_off_fin = 572.099 uV 14:07:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.296 uVs 14:07:36 Integrated Voltage Measurement... 14:07:45 Voltage Offset Correction: v_off_ini = 587.759 uV, v_off_fin = 582.574 uV 14:07:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.485 uVs 14:07:47 I2Y Average and RMS of Measurements VT = -281.499 +- 3.855 uVs I2Y = -25.898 +- 0.355 uTm^2 14:07:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:02 Integrated Voltage Measurement... 14:08:11 Voltage Offset Correction: v_off_ini = 573.917 uV, v_off_fin = 574.172 uV 14:08:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -51.319 uVs 14:08:11 Integrated Voltage Measurement... 14:08:20 Voltage Offset Correction: v_off_ini = 569.243 uV, v_off_fin = 567.121 uV 14:08:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 59.699 uVs 14:08:20 Integrated Voltage Measurement... 14:08:29 Voltage Offset Correction: v_off_ini = 575.607 uV, v_off_fin = 576.567 uV 14:08:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.786 uVs 14:08:29 Integrated Voltage Measurement... 14:08:38 Voltage Offset Correction: v_off_ini = 555.222 uV, v_off_fin = 573.175 uV 14:08:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.961 uVs 14:08:38 Integrated Voltage Measurement... 14:08:47 Voltage Offset Correction: v_off_ini = 563.127 uV, v_off_fin = 557.479 uV 14:08:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.850 uVs 14:08:47 Integrated Voltage Measurement... 14:08:56 Voltage Offset Correction: v_off_ini = 573.121 uV, v_off_fin = 571.093 uV 14:08:56 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 43.358 uVs 14:09:01 I1X Average and RMS of Measurements VT = -48.329 +- 5.301 uVs I1X = 9.667 +- 1.061 uTm 14:09:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:07 Integrated Voltage Measurement... 14:09:16 Voltage Offset Correction: v_off_ini = 584.204 uV, v_off_fin = 568.771 uV 14:09:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.923 uVs 14:09:16 Integrated Voltage Measurement... 14:09:25 Voltage Offset Correction: v_off_ini = 580.498 uV, v_off_fin = 596.167 uV 14:09:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 265.060 uVs 14:09:25 Integrated Voltage Measurement... 14:09:34 Voltage Offset Correction: v_off_ini = 592.473 uV, v_off_fin = 568.528 uV 14:09:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.246 uVs 14:09:34 Integrated Voltage Measurement... 14:09:43 Voltage Offset Correction: v_off_ini = 576.102 uV, v_off_fin = 589.451 uV 14:09:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 268.715 uVs 14:09:43 Integrated Voltage Measurement... 14:09:52 Voltage Offset Correction: v_off_ini = 575.206 uV, v_off_fin = 550.427 uV 14:09:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -273.225 uVs 14:09:52 Integrated Voltage Measurement... 14:10:01 Voltage Offset Correction: v_off_ini = 550.559 uV, v_off_fin = 565.758 uV 14:10:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 277.455 uVs 14:10:06 I1Y Average and RMS of Measurements VT = -268.937 +- 5.052 uVs I1Y = -53.782 +- 1.007 uTm 14:10:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:10:13 Integrated Voltage Measurement... 14:10:22 Voltage Offset Correction: v_off_ini = 561.125 uV, v_off_fin = 555.510 uV 14:10:22 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -14.729 uVs 14:10:22 Integrated Voltage Measurement... 14:10:31 Voltage Offset Correction: v_off_ini = 573.139 uV, v_off_fin = 579.855 uV 14:10:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.657 uVs 14:10:31 Integrated Voltage Measurement... 14:10:40 Voltage Offset Correction: v_off_ini = 573.309 uV, v_off_fin = 568.443 uV 14:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.334 uVs 14:10:40 Integrated Voltage Measurement... 14:10:49 Voltage Offset Correction: v_off_ini = 566.973 uV, v_off_fin = 572.812 uV 14:10:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.607 uVs 14:10:49 Integrated Voltage Measurement... 14:10:58 Voltage Offset Correction: v_off_ini = 568.273 uV, v_off_fin = 561.810 uV 14:10:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.352 uVs 14:10:58 Integrated Voltage Measurement... 14:11:07 Voltage Offset Correction: v_off_ini = 572.610 uV, v_off_fin = 576.644 uV 14:11:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.936 uVs 14:11:10 I2X Average and RMS of Measurements VT = -24.436 +- 3.019 uVs I2X = 2.248 +- 0.278 uTm^2 14:11:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:18 Integrated Voltage Measurement... 14:11:27 Voltage Offset Correction: v_off_ini = 585.297 uV, v_off_fin = 581.027 uV 14:11:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.373 uVs 14:11:27 Integrated Voltage Measurement... 14:11:36 Voltage Offset Correction: v_off_ini = 584.650 uV, v_off_fin = 585.613 uV 14:11:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.677 uVs 14:11:36 Integrated Voltage Measurement... 14:11:45 Voltage Offset Correction: v_off_ini = 589.218 uV, v_off_fin = 586.539 uV 14:11:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.267 uVs 14:11:45 Integrated Voltage Measurement... 14:11:54 Voltage Offset Correction: v_off_ini = 573.771 uV, v_off_fin = 589.765 uV 14:11:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.563 uVs 14:11:54 Integrated Voltage Measurement... 14:12:03 Voltage Offset Correction: v_off_ini = 587.415 uV, v_off_fin = 577.099 uV 14:12:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.881 uVs 14:12:03 Integrated Voltage Measurement... 14:12:12 Voltage Offset Correction: v_off_ini = 581.382 uV, v_off_fin = 579.264 uV 14:12:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.259 uVs 14:12:14 I2Y Average and RMS of Measurements VT = -271.837 +- 6.995 uVs I2Y = -25.009 +- 0.644 uTm^2 14:12:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:12:29 Integrated Voltage Measurement... 14:12:38 Voltage Offset Correction: v_off_ini = 594.841 uV, v_off_fin = 582.345 uV 14:12:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -52.096 uVs 14:12:38 Integrated Voltage Measurement... 14:12:47 Voltage Offset Correction: v_off_ini = 584.972 uV, v_off_fin = 588.140 uV 14:12:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.418 uVs 14:12:47 Integrated Voltage Measurement... 14:12:56 Voltage Offset Correction: v_off_ini = 594.940 uV, v_off_fin = 592.864 uV 14:12:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.875 uVs 14:12:56 Integrated Voltage Measurement... 14:13:05 Voltage Offset Correction: v_off_ini = 593.348 uV, v_off_fin = 597.455 uV 14:13:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.842 uVs 14:13:05 Integrated Voltage Measurement... 14:13:14 Voltage Offset Correction: v_off_ini = 586.080 uV, v_off_fin = 595.827 uV 14:13:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.028 uVs 14:13:14 Integrated Voltage Measurement... 14:13:23 Voltage Offset Correction: v_off_ini = 607.559 uV, v_off_fin = 601.136 uV 14:13:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.874 uVs 14:13:28 I1X Average and RMS of Measurements VT = -53.189 +- 1.482 uVs I1X = 10.638 +- 0.297 uTm 14:13:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:13:34 Integrated Voltage Measurement... 14:13:43 Voltage Offset Correction: v_off_ini = 603.220 uV, v_off_fin = 585.922 uV 14:13:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.866 uVs 14:13:43 Integrated Voltage Measurement... 14:13:52 Voltage Offset Correction: v_off_ini = 593.588 uV, v_off_fin = 603.363 uV 14:13:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 265.531 uVs 14:13:52 Integrated Voltage Measurement... 14:14:01 Voltage Offset Correction: v_off_ini = 597.926 uV, v_off_fin = 591.426 uV 14:14:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -254.091 uVs 14:14:01 Integrated Voltage Measurement... 14:14:10 Voltage Offset Correction: v_off_ini = 596.621 uV, v_off_fin = 615.664 uV 14:14:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 264.168 uVs 14:14:10 Integrated Voltage Measurement... 14:14:19 Voltage Offset Correction: v_off_ini = 594.356 uV, v_off_fin = 587.128 uV 14:14:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.235 uVs 14:14:19 Integrated Voltage Measurement... 14:14:28 Voltage Offset Correction: v_off_ini = 594.832 uV, v_off_fin = 619.042 uV 14:14:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 266.959 uVs 14:14:33 I1Y Average and RMS of Measurements VT = -260.808 +- 1.418 uVs I1Y = -52.157 +- 0.285 uTm 14:14:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:40 Integrated Voltage Measurement... 14:14:49 Voltage Offset Correction: v_off_ini = 590.502 uV, v_off_fin = 587.907 uV 14:14:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.778 uVs 14:14:49 Integrated Voltage Measurement... 14:14:58 Voltage Offset Correction: v_off_ini = 587.207 uV, v_off_fin = 596.478 uV 14:14:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.001 uVs 14:14:58 Integrated Voltage Measurement... 14:15:07 Voltage Offset Correction: v_off_ini = 596.238 uV, v_off_fin = 596.023 uV 14:15:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.818 uVs 14:15:07 Integrated Voltage Measurement... 14:15:16 Voltage Offset Correction: v_off_ini = 590.830 uV, v_off_fin = 606.347 uV 14:15:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.484 uVs 14:15:16 Integrated Voltage Measurement... 14:15:25 Voltage Offset Correction: v_off_ini = 596.672 uV, v_off_fin = 594.883 uV 14:15:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.737 uVs 14:15:26 Integrated Voltage Measurement... 14:15:35 Voltage Offset Correction: v_off_ini = 591.727 uV, v_off_fin = 599.154 uV 14:15:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.728 uVs 14:15:37 I2X Average and RMS of Measurements VT = -35.258 +- 0.615 uVs I2X = 3.244 +- 0.057 uTm^2 14:15:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:15:45 Integrated Voltage Measurement... 14:15:54 Voltage Offset Correction: v_off_ini = 598.826 uV, v_off_fin = 596.257 uV 14:15:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.297 uVs 14:15:54 Integrated Voltage Measurement... 14:16:03 Voltage Offset Correction: v_off_ini = 601.199 uV, v_off_fin = 603.733 uV 14:16:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.923 uVs 14:16:03 Integrated Voltage Measurement... 14:16:12 Voltage Offset Correction: v_off_ini = 598.997 uV, v_off_fin = 601.087 uV 14:16:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.733 uVs 14:16:12 Integrated Voltage Measurement... 14:16:21 Voltage Offset Correction: v_off_ini = 605.138 uV, v_off_fin = 611.489 uV 14:16:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.474 uVs 14:16:21 Integrated Voltage Measurement... 14:16:30 Voltage Offset Correction: v_off_ini = 603.837 uV, v_off_fin = 604.747 uV 14:16:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.373 uVs 14:16:30 Integrated Voltage Measurement... 14:16:39 Voltage Offset Correction: v_off_ini = 614.652 uV, v_off_fin = 615.981 uV 14:16:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.567 uVs 14:16:41 I2Y Average and RMS of Measurements VT = -275.061 +- 4.258 uVs I2Y = -25.306 +- 0.392 uTm^2 14:16:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:56 Integrated Voltage Measurement... 14:17:05 Voltage Offset Correction: v_off_ini = 634.284 uV, v_off_fin = 613.756 uV 14:17:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.589 uVs 14:17:06 Integrated Voltage Measurement... 14:17:15 Voltage Offset Correction: v_off_ini = 619.883 uV, v_off_fin = 618.410 uV 14:17:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.743 uVs 14:17:15 Integrated Voltage Measurement... 14:17:24 Voltage Offset Correction: v_off_ini = 622.109 uV, v_off_fin = 615.057 uV 14:17:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.046 uVs 14:17:24 Integrated Voltage Measurement... 14:17:33 Voltage Offset Correction: v_off_ini = 621.801 uV, v_off_fin = 616.102 uV 14:17:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.753 uVs 14:17:33 Integrated Voltage Measurement... 14:17:42 Voltage Offset Correction: v_off_ini = 609.108 uV, v_off_fin = 604.802 uV 14:17:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.487 uVs 14:17:42 Integrated Voltage Measurement... 14:17:51 Voltage Offset Correction: v_off_ini = 617.513 uV, v_off_fin = 604.945 uV 14:17:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.304 uVs 14:17:55 I1X Average and RMS of Measurements VT = -47.987 +- 7.343 uVs I1X = 9.598 +- 1.468 uTm 14:17:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:02 Integrated Voltage Measurement... 14:18:11 Voltage Offset Correction: v_off_ini = 607.502 uV, v_off_fin = 596.555 uV 14:18:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.882 uVs 14:18:11 Integrated Voltage Measurement... 14:18:20 Voltage Offset Correction: v_off_ini = 611.798 uV, v_off_fin = 617.617 uV 14:18:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 253.444 uVs 14:18:20 Integrated Voltage Measurement... 14:18:29 Voltage Offset Correction: v_off_ini = 616.191 uV, v_off_fin = 595.960 uV 14:18:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -251.247 uVs 14:18:29 Integrated Voltage Measurement... 14:18:38 Voltage Offset Correction: v_off_ini = 599.727 uV, v_off_fin = 622.058 uV 14:18:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 267.061 uVs 14:18:38 Integrated Voltage Measurement... 14:18:47 Voltage Offset Correction: v_off_ini = 627.178 uV, v_off_fin = 606.343 uV 14:18:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -258.750 uVs 14:18:47 Integrated Voltage Measurement... 14:18:56 Voltage Offset Correction: v_off_ini = 613.551 uV, v_off_fin = 621.239 uV 14:18:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 254.722 uVs 14:19:00 I1Y Average and RMS of Measurements VT = -253.351 +- 6.571 uVs I1Y = -50.664 +- 1.312 uTm 14:19:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:08 Integrated Voltage Measurement... 14:19:17 Voltage Offset Correction: v_off_ini = 600.076 uV, v_off_fin = 604.128 uV 14:19:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -5.853 uVs 14:19:17 Integrated Voltage Measurement... 14:19:26 Voltage Offset Correction: v_off_ini = 604.585 uV, v_off_fin = 628.909 uV 14:19:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 17.773 uVs 14:19:26 Integrated Voltage Measurement... 14:19:35 Voltage Offset Correction: v_off_ini = 617.573 uV, v_off_fin = 615.556 uV 14:19:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.480 uVs 14:19:35 Integrated Voltage Measurement... 14:19:44 Voltage Offset Correction: v_off_ini = 625.639 uV, v_off_fin = 617.812 uV 14:19:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 9.629 uVs 14:19:44 Integrated Voltage Measurement... 14:19:53 Voltage Offset Correction: v_off_ini = 612.131 uV, v_off_fin = 609.125 uV 14:19:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.600 uVs 14:19:53 Integrated Voltage Measurement... 14:20:02 Voltage Offset Correction: v_off_ini = 608.432 uV, v_off_fin = 617.942 uV 14:20:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.241 uVs 14:20:04 I2X Average and RMS of Measurements VT = -21.429 +- 8.718 uVs I2X = 1.972 +- 0.802 uTm^2 14:20:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:12 Integrated Voltage Measurement... 14:20:21 Voltage Offset Correction: v_off_ini = 605.151 uV, v_off_fin = 601.307 uV 14:20:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.595 uVs 14:20:21 Integrated Voltage Measurement... 14:20:30 Voltage Offset Correction: v_off_ini = 610.308 uV, v_off_fin = 614.977 uV 14:20:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.312 uVs 14:20:30 Integrated Voltage Measurement... 14:20:39 Voltage Offset Correction: v_off_ini = 614.271 uV, v_off_fin = 612.369 uV 14:20:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.078 uVs 14:20:39 Integrated Voltage Measurement... 14:20:48 Voltage Offset Correction: v_off_ini = 620.419 uV, v_off_fin = 618.065 uV 14:20:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.060 uVs 14:20:48 Integrated Voltage Measurement... 14:20:57 Voltage Offset Correction: v_off_ini = 628.338 uV, v_off_fin = 621.036 uV 14:20:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.635 uVs 14:20:57 Integrated Voltage Measurement... 14:21:06 Voltage Offset Correction: v_off_ini = 615.411 uV, v_off_fin = 621.753 uV 14:21:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.518 uVs 14:21:09 I2Y Average and RMS of Measurements VT = -255.366 +- 5.972 uVs I2Y = -23.494 +- 0.549 uTm^2 14:21:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:21:24 Integrated Voltage Measurement... 14:21:33 Voltage Offset Correction: v_off_ini = 620.656 uV, v_off_fin = 626.363 uV 14:21:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -57.124 uVs 14:21:33 Integrated Voltage Measurement... 14:21:42 Voltage Offset Correction: v_off_ini = 623.181 uV, v_off_fin = 621.216 uV 14:21:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.903 uVs 14:21:42 Integrated Voltage Measurement... 14:21:51 Voltage Offset Correction: v_off_ini = 620.150 uV, v_off_fin = 621.643 uV 14:21:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.031 uVs 14:21:51 Integrated Voltage Measurement... 14:22:00 Voltage Offset Correction: v_off_ini = 623.655 uV, v_off_fin = 619.823 uV 14:22:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.076 uVs 14:22:00 Integrated Voltage Measurement... 14:22:09 Voltage Offset Correction: v_off_ini = 619.594 uV, v_off_fin = 626.113 uV 14:22:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.086 uVs 14:22:09 Integrated Voltage Measurement... 14:22:18 Voltage Offset Correction: v_off_ini = 616.525 uV, v_off_fin = 620.035 uV 14:22:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.804 uVs 14:22:22 I1X Average and RMS of Measurements VT = -48.504 +- 8.425 uVs I1X = 9.701 +- 1.686 uTm 14:22:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:22:29 Integrated Voltage Measurement... 14:22:38 Voltage Offset Correction: v_off_ini = 606.596 uV, v_off_fin = 587.398 uV 14:22:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.734 uVs 14:22:38 Integrated Voltage Measurement... 14:22:47 Voltage Offset Correction: v_off_ini = 610.361 uV, v_off_fin = 625.115 uV 14:22:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 246.072 uVs 14:22:47 Integrated Voltage Measurement... 14:22:56 Voltage Offset Correction: v_off_ini = 616.032 uV, v_off_fin = 607.456 uV 14:22:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -235.870 uVs 14:22:56 Integrated Voltage Measurement... 14:23:05 Voltage Offset Correction: v_off_ini = 617.155 uV, v_off_fin = 632.363 uV 14:23:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.024 uVs 14:23:05 Integrated Voltage Measurement... 14:23:14 Voltage Offset Correction: v_off_ini = 611.904 uV, v_off_fin = 594.820 uV 14:23:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.059 uVs 14:23:14 Integrated Voltage Measurement... 14:23:23 Voltage Offset Correction: v_off_ini = 612.932 uV, v_off_fin = 624.563 uV 14:23:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 252.315 uVs 14:23:27 I1Y Average and RMS of Measurements VT = -238.179 +- 3.627 uVs I1Y = -47.632 +- 0.726 uTm 14:23:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:23:35 Integrated Voltage Measurement... 14:23:44 Voltage Offset Correction: v_off_ini = 614.190 uV, v_off_fin = 608.022 uV 14:23:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -6.358 uVs 14:23:44 Integrated Voltage Measurement... 14:23:53 Voltage Offset Correction: v_off_ini = 607.655 uV, v_off_fin = 624.676 uV 14:23:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.398 uVs 14:23:53 Integrated Voltage Measurement... 14:24:02 Voltage Offset Correction: v_off_ini = 614.673 uV, v_off_fin = 604.175 uV 14:24:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -26.127 uVs 14:24:02 Integrated Voltage Measurement... 14:24:11 Voltage Offset Correction: v_off_ini = 617.846 uV, v_off_fin = 620.380 uV 14:24:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 31.973 uVs 14:24:12 Integrated Voltage Measurement... 14:24:21 Voltage Offset Correction: v_off_ini = 627.923 uV, v_off_fin = 610.706 uV 14:24:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -21.815 uVs 14:24:21 Integrated Voltage Measurement... 14:24:30 Voltage Offset Correction: v_off_ini = 614.848 uV, v_off_fin = 627.893 uV 14:24:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.488 uVs 14:24:32 I2X Average and RMS of Measurements VT = -21.027 +- 8.133 uVs I2X = 1.935 +- 0.748 uTm^2 14:24:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:24:40 Integrated Voltage Measurement... 14:24:49 Voltage Offset Correction: v_off_ini = 608.908 uV, v_off_fin = 610.536 uV 14:24:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -236.569 uVs 14:24:49 Integrated Voltage Measurement... 14:24:58 Voltage Offset Correction: v_off_ini = 616.560 uV, v_off_fin = 619.731 uV 14:24:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.867 uVs 14:24:58 Integrated Voltage Measurement... 14:25:07 Voltage Offset Correction: v_off_ini = 622.036 uV, v_off_fin = 613.310 uV 14:25:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.489 uVs 14:25:07 Integrated Voltage Measurement... 14:25:16 Voltage Offset Correction: v_off_ini = 611.260 uV, v_off_fin = 616.727 uV 14:25:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 265.719 uVs 14:25:16 Integrated Voltage Measurement... 14:25:25 Voltage Offset Correction: v_off_ini = 611.283 uV, v_off_fin = 609.469 uV 14:25:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -263.433 uVs 14:25:25 Integrated Voltage Measurement... 14:25:34 Voltage Offset Correction: v_off_ini = 608.667 uV, v_off_fin = 611.568 uV 14:25:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 229.201 uVs 14:25:36 I2Y Average and RMS of Measurements VT = -248.713 +- 8.093 uVs I2Y = -22.882 +- 0.744 uTm^2 14:25:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:25:51 Integrated Voltage Measurement... 14:26:00 Voltage Offset Correction: v_off_ini = 624.019 uV, v_off_fin = 613.603 uV 14:26:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -58.882 uVs 14:26:00 Integrated Voltage Measurement... 14:26:09 Voltage Offset Correction: v_off_ini = 618.547 uV, v_off_fin = 622.005 uV 14:26:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.979 uVs 14:26:09 Integrated Voltage Measurement... 14:26:18 Voltage Offset Correction: v_off_ini = 620.510 uV, v_off_fin = 627.464 uV 14:26:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.469 uVs 14:26:18 Integrated Voltage Measurement... 14:26:27 Voltage Offset Correction: v_off_ini = 634.998 uV, v_off_fin = 632.662 uV 14:26:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.891 uVs 14:26:28 Integrated Voltage Measurement... 14:26:36 Voltage Offset Correction: v_off_ini = 625.404 uV, v_off_fin = 629.938 uV 14:26:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.134 uVs 14:26:37 Integrated Voltage Measurement... 14:26:46 Voltage Offset Correction: v_off_ini = 626.180 uV, v_off_fin = 635.499 uV 14:26:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.801 uVs 14:26:50 I1X Average and RMS of Measurements VT = -44.360 +- 4.022 uVs I1X = 8.873 +- 0.805 uTm 14:26:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:57 Integrated Voltage Measurement... 14:27:06 Voltage Offset Correction: v_off_ini = 628.277 uV, v_off_fin = 612.920 uV 14:27:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -231.732 uVs 14:27:06 Integrated Voltage Measurement... 14:27:15 Voltage Offset Correction: v_off_ini = 617.480 uV, v_off_fin = 646.164 uV 14:27:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 238.204 uVs 14:27:15 Integrated Voltage Measurement... 14:27:24 Voltage Offset Correction: v_off_ini = 625.751 uV, v_off_fin = 619.526 uV 14:27:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -248.025 uVs 14:27:24 Integrated Voltage Measurement... 14:27:33 Voltage Offset Correction: v_off_ini = 628.912 uV, v_off_fin = 642.653 uV 14:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 234.324 uVs 14:27:33 Integrated Voltage Measurement... 14:27:42 Voltage Offset Correction: v_off_ini = 629.807 uV, v_off_fin = 624.775 uV 14:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -236.025 uVs 14:27:42 Integrated Voltage Measurement... 14:27:51 Voltage Offset Correction: v_off_ini = 637.072 uV, v_off_fin = 652.257 uV 14:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 246.761 uVs 14:27:55 I1Y Average and RMS of Measurements VT = -239.179 +- 2.978 uVs I1Y = -47.829 +- 0.596 uTm 14:28:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:28:03 Integrated Voltage Measurement... 14:28:12 Voltage Offset Correction: v_off_ini = 630.457 uV, v_off_fin = 631.529 uV 14:28:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -8.055 uVs 14:28:12 Integrated Voltage Measurement... 14:28:21 Voltage Offset Correction: v_off_ini = 616.714 uV, v_off_fin = 631.373 uV 14:28:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.306 uVs 14:28:21 Integrated Voltage Measurement... 14:28:30 Voltage Offset Correction: v_off_ini = 619.014 uV, v_off_fin = 616.477 uV 14:28:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.641 uVs 14:28:30 Integrated Voltage Measurement... 14:28:39 Voltage Offset Correction: v_off_ini = 627.354 uV, v_off_fin = 631.844 uV 14:28:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.911 uVs 14:28:39 Integrated Voltage Measurement... 14:28:48 Voltage Offset Correction: v_off_ini = 609.994 uV, v_off_fin = 612.047 uV 14:28:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -16.787 uVs 14:28:48 Integrated Voltage Measurement... 14:28:57 Voltage Offset Correction: v_off_ini = 615.951 uV, v_off_fin = 633.595 uV 14:28:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 0.069 uVs 14:28:59 I2X Average and RMS of Measurements VT = -15.295 +- 4.876 uVs I2X = 1.407 +- 0.449 uTm^2 14:29:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:07 Integrated Voltage Measurement... 14:29:16 Voltage Offset Correction: v_off_ini = 610.336 uV, v_off_fin = 615.731 uV 14:29:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.126 uVs 14:29:16 Integrated Voltage Measurement... 14:29:25 Voltage Offset Correction: v_off_ini = 612.256 uV, v_off_fin = 613.480 uV 14:29:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.037 uVs 14:29:25 Integrated Voltage Measurement... 14:29:34 Voltage Offset Correction: v_off_ini = 609.852 uV, v_off_fin = 613.225 uV 14:29:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.875 uVs 14:29:34 Integrated Voltage Measurement... 14:29:43 Voltage Offset Correction: v_off_ini = 613.339 uV, v_off_fin = 611.926 uV 14:29:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.170 uVs 14:29:43 Integrated Voltage Measurement... 14:29:52 Voltage Offset Correction: v_off_ini = 608.623 uV, v_off_fin = 622.280 uV 14:29:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.349 uVs 14:29:52 Integrated Voltage Measurement... 14:30:01 Voltage Offset Correction: v_off_ini = 620.418 uV, v_off_fin = 604.204 uV 14:30:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.553 uVs 14:30:04 I2Y Average and RMS of Measurements VT = -241.518 +- 3.112 uVs I2Y = -22.220 +- 0.286 uTm^2 14:30:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:30:19 Integrated Voltage Measurement... 14:30:28 Voltage Offset Correction: v_off_ini = 621.232 uV, v_off_fin = 625.912 uV 14:30:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -46.891 uVs 14:30:28 Integrated Voltage Measurement... 14:30:37 Voltage Offset Correction: v_off_ini = 623.420 uV, v_off_fin = 618.228 uV 14:30:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 36.501 uVs 14:30:37 Integrated Voltage Measurement... 14:30:46 Voltage Offset Correction: v_off_ini = 614.858 uV, v_off_fin = 615.091 uV 14:30:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.197 uVs 14:30:46 Integrated Voltage Measurement... 14:30:55 Voltage Offset Correction: v_off_ini = 627.401 uV, v_off_fin = 614.564 uV 14:30:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.850 uVs 14:30:55 Integrated Voltage Measurement... 14:31:04 Voltage Offset Correction: v_off_ini = 623.507 uV, v_off_fin = 616.663 uV 14:31:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.307 uVs 14:31:04 Integrated Voltage Measurement... 14:31:13 Voltage Offset Correction: v_off_ini = 602.275 uV, v_off_fin = 617.568 uV 14:31:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.258 uVs 14:31:17 I1X Average and RMS of Measurements VT = -43.001 +- 2.717 uVs I1X = 8.601 +- 0.543 uTm 14:31:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:31:24 Integrated Voltage Measurement... 14:31:33 Voltage Offset Correction: v_off_ini = 603.493 uV, v_off_fin = 597.670 uV 14:31:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -222.102 uVs 14:31:33 Integrated Voltage Measurement... 14:31:42 Voltage Offset Correction: v_off_ini = 617.166 uV, v_off_fin = 627.571 uV 14:31:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.958 uVs 14:31:42 Integrated Voltage Measurement... 14:31:51 Voltage Offset Correction: v_off_ini = 606.940 uV, v_off_fin = 607.528 uV 14:31:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.636 uVs 14:31:51 Integrated Voltage Measurement... 14:32:00 Voltage Offset Correction: v_off_ini = 626.103 uV, v_off_fin = 629.064 uV 14:32:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.214 uVs 14:32:00 Integrated Voltage Measurement... 14:32:09 Voltage Offset Correction: v_off_ini = 607.706 uV, v_off_fin = 598.803 uV 14:32:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.367 uVs 14:32:09 Integrated Voltage Measurement... 14:32:18 Voltage Offset Correction: v_off_ini = 619.151 uV, v_off_fin = 623.489 uV 14:32:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 249.911 uVs 14:32:22 I1Y Average and RMS of Measurements VT = -223.531 +- 6.179 uVs I1Y = -44.705 +- 1.235 uTm 14:32:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:32:30 Integrated Voltage Measurement... 14:32:39 Voltage Offset Correction: v_off_ini = 609.840 uV, v_off_fin = 611.772 uV 14:32:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.890 uVs 14:32:39 Integrated Voltage Measurement... 14:32:48 Voltage Offset Correction: v_off_ini = 621.541 uV, v_off_fin = 625.817 uV 14:32:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.580 uVs 14:32:48 Integrated Voltage Measurement... 14:32:57 Voltage Offset Correction: v_off_ini = 612.646 uV, v_off_fin = 602.787 uV 14:32:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.544 uVs 14:32:57 Integrated Voltage Measurement... 14:33:06 Voltage Offset Correction: v_off_ini = 609.473 uV, v_off_fin = 626.331 uV 14:33:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.368 uVs 14:33:06 Integrated Voltage Measurement... 14:33:15 Voltage Offset Correction: v_off_ini = 616.253 uV, v_off_fin = 621.975 uV 14:33:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -10.153 uVs 14:33:15 Integrated Voltage Measurement... 14:33:24 Voltage Offset Correction: v_off_ini = 626.335 uV, v_off_fin = 622.411 uV 14:33:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.025 uVs 14:33:27 I2X Average and RMS of Measurements VT = -19.593 +- 8.326 uVs I2X = 1.803 +- 0.766 uTm^2 14:33:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:33:35 Integrated Voltage Measurement... 14:33:44 Voltage Offset Correction: v_off_ini = 622.323 uV, v_off_fin = 607.507 uV 14:33:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.122 uVs 14:33:44 Integrated Voltage Measurement... 14:33:53 Voltage Offset Correction: v_off_ini = 612.649 uV, v_off_fin = 620.090 uV 14:33:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.379 uVs 14:33:53 Integrated Voltage Measurement... 14:34:02 Voltage Offset Correction: v_off_ini = 628.957 uV, v_off_fin = 619.710 uV 14:34:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.548 uVs 14:34:02 Integrated Voltage Measurement... 14:34:11 Voltage Offset Correction: v_off_ini = 619.469 uV, v_off_fin = 624.953 uV 14:34:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.204 uVs 14:34:11 Integrated Voltage Measurement... 14:34:20 Voltage Offset Correction: v_off_ini = 631.349 uV, v_off_fin = 621.925 uV 14:34:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.259 uVs 14:34:20 Integrated Voltage Measurement... 14:34:29 Voltage Offset Correction: v_off_ini = 619.315 uV, v_off_fin = 617.397 uV 14:34:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.401 uVs 14:34:31 I2Y Average and RMS of Measurements VT = -238.819 +- 5.972 uVs I2Y = -21.971 +- 0.549 uTm^2 14:34:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:34:46 Integrated Voltage Measurement... 14:34:55 Voltage Offset Correction: v_off_ini = 631.067 uV, v_off_fin = 631.753 uV 14:34:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -46.343 uVs 14:34:55 Integrated Voltage Measurement... 14:35:04 Voltage Offset Correction: v_off_ini = 634.808 uV, v_off_fin = 633.455 uV 14:35:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.317 uVs 14:35:05 Integrated Voltage Measurement... 14:35:13 Voltage Offset Correction: v_off_ini = 633.603 uV, v_off_fin = 637.471 uV 14:35:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.983 uVs 14:35:14 Integrated Voltage Measurement... 14:35:23 Voltage Offset Correction: v_off_ini = 655.560 uV, v_off_fin = 664.927 uV 14:35:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.948 uVs 14:35:23 Integrated Voltage Measurement... 14:35:32 Voltage Offset Correction: v_off_ini = 662.708 uV, v_off_fin = 652.012 uV 14:35:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.715 uVs 14:35:32 Integrated Voltage Measurement... 14:35:41 Voltage Offset Correction: v_off_ini = 649.389 uV, v_off_fin = 653.744 uV 14:35:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.521 uVs 14:35:45 I1X Average and RMS of Measurements VT = -36.971 +- 0.481 uVs I1X = 7.395 +- 0.096 uTm 14:35:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:35:52 Integrated Voltage Measurement... 14:36:01 Voltage Offset Correction: v_off_ini = 647.221 uV, v_off_fin = 649.337 uV 14:36:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -217.012 uVs 14:36:01 Integrated Voltage Measurement... 14:36:10 Voltage Offset Correction: v_off_ini = 673.240 uV, v_off_fin = 672.655 uV 14:36:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.341 uVs 14:36:10 Integrated Voltage Measurement... 14:36:19 Voltage Offset Correction: v_off_ini = 653.408 uV, v_off_fin = 649.126 uV 14:36:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -221.447 uVs 14:36:19 Integrated Voltage Measurement... 14:36:28 Voltage Offset Correction: v_off_ini = 663.619 uV, v_off_fin = 678.630 uV 14:36:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 235.566 uVs 14:36:28 Integrated Voltage Measurement... 14:36:37 Voltage Offset Correction: v_off_ini = 679.125 uV, v_off_fin = 660.463 uV 14:36:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -226.386 uVs 14:36:37 Integrated Voltage Measurement... 14:36:46 Voltage Offset Correction: v_off_ini = 658.251 uV, v_off_fin = 670.125 uV 14:36:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 232.011 uVs 14:36:50 I1Y Average and RMS of Measurements VT = -223.461 +- 7.631 uVs I1Y = -44.687 +- 1.521 uTm 14:36:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:36:58 Integrated Voltage Measurement... 14:37:07 Voltage Offset Correction: v_off_ini = 664.406 uV, v_off_fin = 653.880 uV 14:37:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -17.423 uVs 14:37:07 Integrated Voltage Measurement... 14:37:16 Voltage Offset Correction: v_off_ini = 657.476 uV, v_off_fin = 660.678 uV 14:37:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.933 uVs 14:37:16 Integrated Voltage Measurement... 14:37:25 Voltage Offset Correction: v_off_ini = 650.007 uV, v_off_fin = 655.822 uV 14:37:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -7.832 uVs 14:37:25 Integrated Voltage Measurement... 14:37:34 Voltage Offset Correction: v_off_ini = 651.434 uV, v_off_fin = 670.016 uV 14:37:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 32.042 uVs 14:37:34 Integrated Voltage Measurement... 14:37:43 Voltage Offset Correction: v_off_ini = 667.514 uV, v_off_fin = 661.558 uV 14:37:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.044 uVs 14:37:43 Integrated Voltage Measurement... 14:37:52 Voltage Offset Correction: v_off_ini = 674.569 uV, v_off_fin = 684.243 uV 14:37:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 12.265 uVs 14:37:54 I2X Average and RMS of Measurements VT = -13.408 +- 5.917 uVs I2X = 1.234 +- 0.544 uTm^2 14:37:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:38:02 Integrated Voltage Measurement... 14:38:11 Voltage Offset Correction: v_off_ini = 673.585 uV, v_off_fin = 668.639 uV 14:38:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.652 uVs 14:38:11 Integrated Voltage Measurement... 14:38:20 Voltage Offset Correction: v_off_ini = 664.276 uV, v_off_fin = 669.916 uV 14:38:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.807 uVs 14:38:20 Integrated Voltage Measurement... 14:38:29 Voltage Offset Correction: v_off_ini = 666.672 uV, v_off_fin = 660.947 uV 14:38:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.669 uVs 14:38:29 Integrated Voltage Measurement... 14:38:38 Voltage Offset Correction: v_off_ini = 668.630 uV, v_off_fin = 661.966 uV 14:38:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.794 uVs 14:38:38 Integrated Voltage Measurement... 14:38:47 Voltage Offset Correction: v_off_ini = 666.673 uV, v_off_fin = 674.006 uV 14:38:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.297 uVs 14:38:47 Integrated Voltage Measurement... 14:38:56 Voltage Offset Correction: v_off_ini = 675.913 uV, v_off_fin = 679.376 uV 14:38:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.461 uVs 14:38:58 I2Y Average and RMS of Measurements VT = -231.780 +- 7.032 uVs I2Y = -21.324 +- 0.647 uTm^2 14:39:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:15 Integrated Voltage Measurement... 14:39:24 Voltage Offset Correction: v_off_ini = 668.636 uV, v_off_fin = 669.165 uV 14:39:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.681 uVs 14:39:24 Integrated Voltage Measurement... 14:39:33 Voltage Offset Correction: v_off_ini = 662.070 uV, v_off_fin = 672.238 uV 14:39:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.062 uVs 14:39:33 Integrated Voltage Measurement... 14:39:42 Voltage Offset Correction: v_off_ini = 668.240 uV, v_off_fin = 665.642 uV 14:39:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -38.428 uVs 14:39:42 Integrated Voltage Measurement... 14:39:51 Voltage Offset Correction: v_off_ini = 675.724 uV, v_off_fin = 670.023 uV 14:39:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.827 uVs 14:39:51 Integrated Voltage Measurement... 14:40:00 Voltage Offset Correction: v_off_ini = 653.610 uV, v_off_fin = 663.167 uV 14:40:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -17.631 uVs 14:40:00 Integrated Voltage Measurement... 14:40:09 Voltage Offset Correction: v_off_ini = 659.336 uV, v_off_fin = 662.269 uV 14:40:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.163 uVs 14:40:13 I1X Average and RMS of Measurements VT = -36.965 +- 7.251 uVs I1X = 7.393 +- 1.450 uTm 14:40:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:20 Integrated Voltage Measurement... 14:40:29 Voltage Offset Correction: v_off_ini = 652.174 uV, v_off_fin = 641.387 uV 14:40:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.411 uVs 14:40:29 Integrated Voltage Measurement... 14:40:38 Voltage Offset Correction: v_off_ini = 659.122 uV, v_off_fin = 682.068 uV 14:40:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.438 uVs 14:40:38 Integrated Voltage Measurement... 14:40:47 Voltage Offset Correction: v_off_ini = 668.642 uV, v_off_fin = 657.554 uV 14:40:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -214.128 uVs 14:40:47 Integrated Voltage Measurement... 14:40:56 Voltage Offset Correction: v_off_ini = 663.079 uV, v_off_fin = 664.736 uV 14:40:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.207 uVs 14:40:56 Integrated Voltage Measurement... 14:41:05 Voltage Offset Correction: v_off_ini = 656.692 uV, v_off_fin = 651.719 uV 14:41:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.703 uVs 14:41:05 Integrated Voltage Measurement... 14:41:14 Voltage Offset Correction: v_off_ini = 661.249 uV, v_off_fin = 672.394 uV 14:41:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.945 uVs 14:41:18 I1Y Average and RMS of Measurements VT = -213.139 +- 6.238 uVs I1Y = -42.625 +- 1.245 uTm 14:41:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:26 Integrated Voltage Measurement... 14:41:35 Voltage Offset Correction: v_off_ini = 664.043 uV, v_off_fin = 659.722 uV 14:41:35 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -5.881 uVs 14:41:35 Integrated Voltage Measurement... 14:41:44 Voltage Offset Correction: v_off_ini = 668.644 uV, v_off_fin = 677.567 uV 14:41:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 2.366 uVs 14:41:44 Integrated Voltage Measurement... 14:41:53 Voltage Offset Correction: v_off_ini = 663.010 uV, v_off_fin = 655.709 uV 14:41:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -5.389 uVs 14:41:53 Integrated Voltage Measurement... 14:42:02 Voltage Offset Correction: v_off_ini = 674.217 uV, v_off_fin = 680.325 uV 14:42:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.393 uVs 14:42:02 Integrated Voltage Measurement... 14:42:11 Voltage Offset Correction: v_off_ini = 667.593 uV, v_off_fin = 669.873 uV 14:42:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -0.433 uVs 14:42:11 Integrated Voltage Measurement... 14:42:20 Voltage Offset Correction: v_off_ini = 679.701 uV, v_off_fin = 690.202 uV 14:42:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.113 uVs 14:42:22 I2X Average and RMS of Measurements VT = -3.132 +- 0.873 uVs I2X = 0.288 +- 0.080 uTm^2 14:42:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:30 Integrated Voltage Measurement... 14:42:39 Voltage Offset Correction: v_off_ini = 680.123 uV, v_off_fin = 676.158 uV 14:42:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -228.126 uVs 14:42:39 Integrated Voltage Measurement... 14:42:48 Voltage Offset Correction: v_off_ini = 676.820 uV, v_off_fin = 677.991 uV 14:42:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.672 uVs 14:42:48 Integrated Voltage Measurement... 14:42:57 Voltage Offset Correction: v_off_ini = 673.475 uV, v_off_fin = 664.171 uV 14:42:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.439 uVs 14:42:57 Integrated Voltage Measurement... 14:43:06 Voltage Offset Correction: v_off_ini = 666.011 uV, v_off_fin = 670.647 uV 14:43:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.429 uVs 14:43:06 Integrated Voltage Measurement... 14:43:15 Voltage Offset Correction: v_off_ini = 682.066 uV, v_off_fin = 686.625 uV 14:43:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.943 uVs 14:43:15 Integrated Voltage Measurement... 14:43:24 Voltage Offset Correction: v_off_ini = 670.745 uV, v_off_fin = 669.755 uV 14:43:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.635 uVs 14:43:27 I2Y Average and RMS of Measurements VT = -218.874 +- 5.457 uVs I2Y = -20.137 +- 0.502 uTm^2 14:43:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:43 Integrated Voltage Measurement... 14:43:52 Voltage Offset Correction: v_off_ini = 675.964 uV, v_off_fin = 671.683 uV 14:43:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -28.043 uVs 14:43:52 Integrated Voltage Measurement... 14:44:01 Voltage Offset Correction: v_off_ini = 678.818 uV, v_off_fin = 683.614 uV 14:44:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 23.414 uVs 14:44:01 Integrated Voltage Measurement... 14:44:10 Voltage Offset Correction: v_off_ini = 672.563 uV, v_off_fin = 670.826 uV 14:44:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -38.978 uVs 14:44:10 Integrated Voltage Measurement... 14:44:19 Voltage Offset Correction: v_off_ini = 670.746 uV, v_off_fin = 679.725 uV 14:44:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.853 uVs 14:44:19 Integrated Voltage Measurement... 14:44:28 Voltage Offset Correction: v_off_ini = 675.535 uV, v_off_fin = 673.178 uV 14:44:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -29.602 uVs 14:44:28 Integrated Voltage Measurement... 14:44:37 Voltage Offset Correction: v_off_ini = 673.926 uV, v_off_fin = 677.615 uV 14:44:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 16.849 uVs 14:44:41 I1X Average and RMS of Measurements VT = -27.957 +- 5.026 uVs I1X = 5.592 +- 1.005 uTm 14:44:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:44:48 Integrated Voltage Measurement... 14:44:57 Voltage Offset Correction: v_off_ini = 670.421 uV, v_off_fin = 657.104 uV 14:44:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.304 uVs 14:44:57 Integrated Voltage Measurement... 14:45:06 Voltage Offset Correction: v_off_ini = 681.464 uV, v_off_fin = 685.202 uV 14:45:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.969 uVs 14:45:06 Integrated Voltage Measurement... 14:45:15 Voltage Offset Correction: v_off_ini = 672.616 uV, v_off_fin = 664.146 uV 14:45:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.926 uVs 14:45:15 Integrated Voltage Measurement... 14:45:24 Voltage Offset Correction: v_off_ini = 658.777 uV, v_off_fin = 675.220 uV 14:45:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.240 uVs 14:45:24 Integrated Voltage Measurement... 14:45:33 Voltage Offset Correction: v_off_ini = 665.302 uV, v_off_fin = 647.297 uV 14:45:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.501 uVs 14:45:33 Integrated Voltage Measurement... 14:45:42 Voltage Offset Correction: v_off_ini = 661.953 uV, v_off_fin = 674.317 uV 14:45:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 205.647 uVs 14:45:46 I1Y Average and RMS of Measurements VT = -206.931 +- 4.732 uVs I1Y = -41.385 +- 0.944 uTm 14:45:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:45:54 Integrated Voltage Measurement... 14:46:03 Voltage Offset Correction: v_off_ini = 664.808 uV, v_off_fin = 654.031 uV 14:46:03 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -15.692 uVs 14:46:03 Integrated Voltage Measurement... 14:46:12 Voltage Offset Correction: v_off_ini = 665.784 uV, v_off_fin = 674.483 uV 14:46:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -0.615 uVs 14:46:12 Integrated Voltage Measurement... 14:46:21 Voltage Offset Correction: v_off_ini = 674.139 uV, v_off_fin = 675.247 uV 14:46:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -5.397 uVs 14:46:21 Integrated Voltage Measurement... 14:46:30 Voltage Offset Correction: v_off_ini = 685.524 uV, v_off_fin = 683.963 uV 14:46:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -4.864 uVs 14:46:30 Integrated Voltage Measurement... 14:46:39 Voltage Offset Correction: v_off_ini = 677.931 uV, v_off_fin = 665.816 uV 14:46:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -5.150 uVs 14:46:39 Integrated Voltage Measurement... 14:46:48 Voltage Offset Correction: v_off_ini = 669.880 uV, v_off_fin = 685.080 uV 14:46:48 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 0.787 uVs 14:46:50 I2X Average and RMS of Measurements VT = -3.591 +- 3.001 uVs I2X = 0.330 +- 0.276 uTm^2 14:46:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:58 Integrated Voltage Measurement... 14:47:07 Voltage Offset Correction: v_off_ini = 666.180 uV, v_off_fin = 672.111 uV 14:47:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.022 uVs 14:47:07 Integrated Voltage Measurement... 14:47:16 Voltage Offset Correction: v_off_ini = 673.094 uV, v_off_fin = 676.258 uV 14:47:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.641 uVs 14:47:16 Integrated Voltage Measurement... 14:47:25 Voltage Offset Correction: v_off_ini = 675.405 uV, v_off_fin = 672.079 uV 14:47:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.020 uVs 14:47:25 Integrated Voltage Measurement... 14:47:34 Voltage Offset Correction: v_off_ini = 657.534 uV, v_off_fin = 676.261 uV 14:47:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.290 uVs 14:47:34 Integrated Voltage Measurement... 14:47:43 Voltage Offset Correction: v_off_ini = 677.741 uV, v_off_fin = 669.833 uV 14:47:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.080 uVs 14:47:43 Integrated Voltage Measurement... 14:47:52 Voltage Offset Correction: v_off_ini = 674.962 uV, v_off_fin = 672.426 uV 14:47:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.582 uVs 14:47:55 I2Y Average and RMS of Measurements VT = -208.439 +- 11.153 uVs I2Y = -19.176 +- 1.026 uTm^2 14:48:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:13 Integrated Voltage Measurement... 14:48:22 Voltage Offset Correction: v_off_ini = 670.876 uV, v_off_fin = 661.543 uV 14:48:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -46.569 uVs 14:48:22 Integrated Voltage Measurement... 14:48:31 Voltage Offset Correction: v_off_ini = 663.910 uV, v_off_fin = 669.464 uV 14:48:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.087 uVs 14:48:31 Integrated Voltage Measurement... 14:48:40 Voltage Offset Correction: v_off_ini = 664.445 uV, v_off_fin = 654.549 uV 14:48:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.198 uVs 14:48:40 Integrated Voltage Measurement... 14:48:49 Voltage Offset Correction: v_off_ini = 670.506 uV, v_off_fin = 668.247 uV 14:48:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.977 uVs 14:48:49 Integrated Voltage Measurement... 14:48:58 Voltage Offset Correction: v_off_ini = 646.257 uV, v_off_fin = 654.186 uV 14:48:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -36.051 uVs 14:48:58 Integrated Voltage Measurement... 14:49:07 Voltage Offset Correction: v_off_ini = 657.058 uV, v_off_fin = 664.521 uV 14:49:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.851 uVs 14:49:11 I1X Average and RMS of Measurements VT = -33.955 +- 2.127 uVs I1X = 6.792 +- 0.426 uTm 14:49:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:18 Integrated Voltage Measurement... 14:49:27 Voltage Offset Correction: v_off_ini = 643.662 uV, v_off_fin = 644.485 uV 14:49:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.325 uVs 14:49:27 Integrated Voltage Measurement... 14:49:36 Voltage Offset Correction: v_off_ini = 658.452 uV, v_off_fin = 662.700 uV 14:49:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 193.724 uVs 14:49:36 Integrated Voltage Measurement... 14:49:45 Voltage Offset Correction: v_off_ini = 646.537 uV, v_off_fin = 638.269 uV 14:49:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.697 uVs 14:49:45 Integrated Voltage Measurement... 14:49:54 Voltage Offset Correction: v_off_ini = 668.694 uV, v_off_fin = 672.891 uV 14:49:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.527 uVs 14:49:54 Integrated Voltage Measurement... 14:50:03 Voltage Offset Correction: v_off_ini = 666.091 uV, v_off_fin = 641.545 uV 14:50:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.800 uVs 14:50:03 Integrated Voltage Measurement... 14:50:12 Voltage Offset Correction: v_off_ini = 656.676 uV, v_off_fin = 664.266 uV 14:50:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 175.905 uVs 14:50:16 I1Y Average and RMS of Measurements VT = -186.663 +- 2.845 uVs I1Y = -37.333 +- 0.568 uTm 14:50:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:50:24 Integrated Voltage Measurement... 14:50:33 Voltage Offset Correction: v_off_ini = 661.472 uV, v_off_fin = 662.236 uV 14:50:33 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -27.227 uVs 14:50:33 Integrated Voltage Measurement... 14:50:42 Voltage Offset Correction: v_off_ini = 669.032 uV, v_off_fin = 682.694 uV 14:50:42 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = -2.977 uVs 14:50:42 Integrated Voltage Measurement... 14:50:51 Voltage Offset Correction: v_off_ini = 668.543 uV, v_off_fin = 661.536 uV 14:50:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 4.945 uVs 14:50:51 Integrated Voltage Measurement... 14:51:00 Voltage Offset Correction: v_off_ini = 679.196 uV, v_off_fin = 693.215 uV 14:51:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.017 uVs 14:51:00 Integrated Voltage Measurement... 14:51:09 Voltage Offset Correction: v_off_ini = 692.413 uV, v_off_fin = 674.775 uV 14:51:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.965 uVs 14:51:09 Integrated Voltage Measurement... 14:51:18 Voltage Offset Correction: v_off_ini = 679.785 uV, v_off_fin = 687.049 uV 14:51:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 7.513 uVs 14:51:20 I2X Average and RMS of Measurements VT = -8.294 +- 9.663 uVs I2X = 0.763 +- 0.889 uTm^2 14:51:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:28 Integrated Voltage Measurement... 14:51:37 Voltage Offset Correction: v_off_ini = 674.299 uV, v_off_fin = 675.520 uV 14:51:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.812 uVs 14:51:37 Integrated Voltage Measurement... 14:51:46 Voltage Offset Correction: v_off_ini = 680.611 uV, v_off_fin = 671.509 uV 14:51:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.124 uVs 14:51:46 Integrated Voltage Measurement... 14:51:55 Voltage Offset Correction: v_off_ini = 677.679 uV, v_off_fin = 673.428 uV 14:51:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.211 uVs 14:51:55 Integrated Voltage Measurement... 14:52:04 Voltage Offset Correction: v_off_ini = 674.565 uV, v_off_fin = 677.517 uV 14:52:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.474 uVs 14:52:04 Integrated Voltage Measurement... 14:52:13 Voltage Offset Correction: v_off_ini = 671.982 uV, v_off_fin = 671.764 uV 14:52:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.360 uVs 14:52:13 Integrated Voltage Measurement... 14:52:22 Voltage Offset Correction: v_off_ini = 667.229 uV, v_off_fin = 674.500 uV 14:52:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.960 uVs 14:52:25 I2Y Average and RMS of Measurements VT = -188.824 +- 3.560 uVs I2Y = -17.372 +- 0.328 uTm^2 14:52:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:43 Integrated Voltage Measurement... 14:52:52 Voltage Offset Correction: v_off_ini = 675.031 uV, v_off_fin = 660.774 uV 14:52:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -40.950 uVs 14:52:52 Integrated Voltage Measurement... 14:53:01 Voltage Offset Correction: v_off_ini = 687.729 uV, v_off_fin = 680.604 uV 14:53:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 8.829 uVs 14:53:01 Integrated Voltage Measurement... 14:53:10 Voltage Offset Correction: v_off_ini = 669.962 uV, v_off_fin = 664.440 uV 14:53:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -11.182 uVs 14:53:10 Integrated Voltage Measurement... 14:53:19 Voltage Offset Correction: v_off_ini = 668.332 uV, v_off_fin = 662.312 uV 14:53:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.651 uVs 14:53:19 Integrated Voltage Measurement... 14:53:28 Voltage Offset Correction: v_off_ini = 659.756 uV, v_off_fin = 664.168 uV 14:53:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -39.628 uVs 14:53:28 Integrated Voltage Measurement... 14:53:37 Voltage Offset Correction: v_off_ini = 662.573 uV, v_off_fin = 650.417 uV 14:53:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 58.280 uVs 14:53:41 I1X Average and RMS of Measurements VT = -32.586 +- 11.580 uVs I1X = 6.518 +- 2.316 uTm 14:53:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:48 Integrated Voltage Measurement... 14:53:57 Voltage Offset Correction: v_off_ini = 674.111 uV, v_off_fin = 657.695 uV 14:53:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.105 uVs 14:53:57 Integrated Voltage Measurement... 14:54:06 Voltage Offset Correction: v_off_ini = 664.360 uV, v_off_fin = 679.124 uV 14:54:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.640 uVs 14:54:06 Integrated Voltage Measurement... 14:54:15 Voltage Offset Correction: v_off_ini = 671.865 uV, v_off_fin = 655.938 uV 14:54:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.032 uVs 14:54:15 Integrated Voltage Measurement... 14:54:24 Voltage Offset Correction: v_off_ini = 664.243 uV, v_off_fin = 674.492 uV 14:54:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.945 uVs 14:54:24 Integrated Voltage Measurement... 14:54:33 Voltage Offset Correction: v_off_ini = 667.901 uV, v_off_fin = 670.167 uV 14:54:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -171.294 uVs 14:54:33 Integrated Voltage Measurement... 14:54:42 Voltage Offset Correction: v_off_ini = 662.220 uV, v_off_fin = 674.375 uV 14:54:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 188.278 uVs 14:54:46 I1Y Average and RMS of Measurements VT = -177.382 +- 1.718 uVs I1Y = -35.478 +- 0.345 uTm 14:54:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:54 Integrated Voltage Measurement... 14:55:03 Voltage Offset Correction: v_off_ini = 656.585 uV, v_off_fin = 662.481 uV 14:55:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -12.427 uVs 14:55:03 Integrated Voltage Measurement... 14:55:12 Voltage Offset Correction: v_off_ini = 665.310 uV, v_off_fin = 669.733 uV 14:55:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 10.213 uVs 14:55:12 Integrated Voltage Measurement... 14:55:21 Voltage Offset Correction: v_off_ini = 675.368 uV, v_off_fin = 664.195 uV 14:55:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.407 uVs 14:55:22 Integrated Voltage Measurement... 14:55:30 Voltage Offset Correction: v_off_ini = 676.383 uV, v_off_fin = 669.985 uV 14:55:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 7.893 uVs 14:55:31 Integrated Voltage Measurement... 14:55:40 Voltage Offset Correction: v_off_ini = 664.701 uV, v_off_fin = 660.004 uV 14:55:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -28.165 uVs 14:55:40 Integrated Voltage Measurement... 14:55:49 Voltage Offset Correction: v_off_ini = 678.814 uV, v_off_fin = 676.844 uV 14:55:49 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = -4.164 uVs 14:55:51 I2X Average and RMS of Measurements VT = -12.823 +- 1.668 uVs I2X = 1.180 +- 0.153 uTm^2 14:55:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:59 Integrated Voltage Measurement... 14:56:08 Voltage Offset Correction: v_off_ini = 656.019 uV, v_off_fin = 659.434 uV 14:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.734 uVs 14:56:08 Integrated Voltage Measurement... 14:56:17 Voltage Offset Correction: v_off_ini = 660.561 uV, v_off_fin = 675.571 uV 14:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.043 uVs 14:56:17 Integrated Voltage Measurement... 14:56:26 Voltage Offset Correction: v_off_ini = 675.057 uV, v_off_fin = 677.300 uV 14:56:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.315 uVs 14:56:26 Integrated Voltage Measurement... 14:56:35 Voltage Offset Correction: v_off_ini = 666.721 uV, v_off_fin = 663.410 uV 14:56:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.127 uVs 14:56:35 Integrated Voltage Measurement... 14:56:44 Voltage Offset Correction: v_off_ini = 673.752 uV, v_off_fin = 670.599 uV 14:56:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.297 uVs 14:56:44 Integrated Voltage Measurement... 14:56:53 Voltage Offset Correction: v_off_ini = 676.797 uV, v_off_fin = 664.832 uV 14:56:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.069 uVs 14:56:55 I2Y Average and RMS of Measurements VT = -179.764 +- 2.394 uVs I2Y = -16.538 +- 0.220 uTm^2 14:57:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:14 Integrated Voltage Measurement... 14:57:23 Voltage Offset Correction: v_off_ini = 660.944 uV, v_off_fin = 664.388 uV 14:57:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -47.067 uVs 14:57:23 Integrated Voltage Measurement... 14:57:32 Voltage Offset Correction: v_off_ini = 670.530 uV, v_off_fin = 681.945 uV 14:57:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 25.188 uVs 14:57:32 Integrated Voltage Measurement... 14:57:41 Voltage Offset Correction: v_off_ini = 661.019 uV, v_off_fin = 667.201 uV 14:57:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.015 uVs 14:57:41 Integrated Voltage Measurement... 14:57:50 Voltage Offset Correction: v_off_ini = 663.233 uV, v_off_fin = 659.720 uV 14:57:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.641 uVs 14:57:50 Integrated Voltage Measurement... 14:57:59 Voltage Offset Correction: v_off_ini = 671.851 uV, v_off_fin = 663.960 uV 14:57:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.195 uVs 14:57:59 Integrated Voltage Measurement... 14:58:08 Voltage Offset Correction: v_off_ini = 669.290 uV, v_off_fin = 660.443 uV 14:58:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.937 uVs 14:58:12 I1X Average and RMS of Measurements VT = -39.007 +- 2.060 uVs I1X = 7.802 +- 0.411 uTm 14:58:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:19 Integrated Voltage Measurement... 14:58:28 Voltage Offset Correction: v_off_ini = 666.052 uV, v_off_fin = 654.391 uV 14:58:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -162.609 uVs 14:58:28 Integrated Voltage Measurement... 14:58:37 Voltage Offset Correction: v_off_ini = 663.139 uV, v_off_fin = 678.343 uV 14:58:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 170.543 uVs 14:58:37 Integrated Voltage Measurement... 14:58:46 Voltage Offset Correction: v_off_ini = 674.693 uV, v_off_fin = 649.639 uV 14:58:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -164.922 uVs 14:58:46 Integrated Voltage Measurement... 14:58:55 Voltage Offset Correction: v_off_ini = 676.810 uV, v_off_fin = 681.421 uV 14:58:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.833 uVs 14:58:55 Integrated Voltage Measurement... 14:59:04 Voltage Offset Correction: v_off_ini = 672.906 uV, v_off_fin = 653.173 uV 14:59:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.613 uVs 14:59:04 Integrated Voltage Measurement... 14:59:13 Voltage Offset Correction: v_off_ini = 661.815 uV, v_off_fin = 669.008 uV 14:59:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 178.350 uVs 14:59:18 I1Y Average and RMS of Measurements VT = -173.645 +- 7.780 uVs I1Y = -34.730 +- 1.555 uTm 14:59:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:25 Integrated Voltage Measurement... 14:59:34 Voltage Offset Correction: v_off_ini = 648.459 uV, v_off_fin = 651.687 uV 14:59:34 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -16.107 uVs 14:59:34 Integrated Voltage Measurement... 14:59:43 Voltage Offset Correction: v_off_ini = 659.849 uV, v_off_fin = 672.104 uV 14:59:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 0.644 uVs 14:59:43 Integrated Voltage Measurement... 14:59:52 Voltage Offset Correction: v_off_ini = 662.027 uV, v_off_fin = 658.472 uV 14:59:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -32.362 uVs 14:59:52 Integrated Voltage Measurement... 15:00:01 Voltage Offset Correction: v_off_ini = 656.941 uV, v_off_fin = 669.579 uV 15:00:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 32.407 uVs 15:00:02 Integrated Voltage Measurement... 15:00:11 Voltage Offset Correction: v_off_ini = 674.185 uV, v_off_fin = 668.693 uV 15:00:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.119 uVs 15:00:11 Integrated Voltage Measurement... 15:00:20 Voltage Offset Correction: v_off_ini = 674.985 uV, v_off_fin = 680.873 uV 15:00:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -0.087 uVs 15:00:22 I2X Average and RMS of Measurements VT = -19.425 +- 9.894 uVs I2X = 1.787 +- 0.910 uTm^2 15:00:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:30 Integrated Voltage Measurement... 15:00:39 Voltage Offset Correction: v_off_ini = 679.125 uV, v_off_fin = 685.795 uV 15:00:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.686 uVs 15:00:39 Integrated Voltage Measurement... 15:00:48 Voltage Offset Correction: v_off_ini = 681.574 uV, v_off_fin = 673.654 uV 15:00:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.236 uVs 15:00:48 Integrated Voltage Measurement... 15:00:57 Voltage Offset Correction: v_off_ini = 679.342 uV, v_off_fin = 669.907 uV 15:00:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.917 uVs 15:00:57 Integrated Voltage Measurement... 15:01:06 Voltage Offset Correction: v_off_ini = 661.287 uV, v_off_fin = 669.531 uV 15:01:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 166.323 uVs 15:01:06 Integrated Voltage Measurement... 15:01:15 Voltage Offset Correction: v_off_ini = 678.279 uV, v_off_fin = 671.870 uV 15:01:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.701 uVs 15:01:15 Integrated Voltage Measurement... 15:01:24 Voltage Offset Correction: v_off_ini = 678.088 uV, v_off_fin = 684.021 uV 15:01:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 159.284 uVs 15:01:27 I2Y Average and RMS of Measurements VT = -171.691 +- 3.725 uVs I2Y = -15.796 +- 0.343 uTm^2 15:01:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:45 Integrated Voltage Measurement... 15:01:54 Voltage Offset Correction: v_off_ini = 692.291 uV, v_off_fin = 673.010 uV 15:01:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.733 uVs 15:01:55 Integrated Voltage Measurement... 15:02:03 Voltage Offset Correction: v_off_ini = 673.257 uV, v_off_fin = 682.799 uV 15:02:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 40.516 uVs 15:02:04 Integrated Voltage Measurement... 15:02:13 Voltage Offset Correction: v_off_ini = 678.880 uV, v_off_fin = 682.034 uV 15:02:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.492 uVs 15:02:13 Integrated Voltage Measurement... 15:02:22 Voltage Offset Correction: v_off_ini = 671.772 uV, v_off_fin = 683.241 uV 15:02:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 36.379 uVs 15:02:22 Integrated Voltage Measurement... 15:02:31 Voltage Offset Correction: v_off_ini = 682.719 uV, v_off_fin = 682.541 uV 15:02:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -56.821 uVs 15:02:31 Integrated Voltage Measurement... 15:02:40 Voltage Offset Correction: v_off_ini = 685.190 uV, v_off_fin = 681.509 uV 15:02:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.580 uVs 15:02:44 I1X Average and RMS of Measurements VT = -48.920 +- 6.012 uVs I1X = 9.784 +- 1.203 uTm 15:02:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:51 Integrated Voltage Measurement... 15:03:00 Voltage Offset Correction: v_off_ini = 683.598 uV, v_off_fin = 673.849 uV 15:03:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -171.250 uVs 15:03:00 Integrated Voltage Measurement... 15:03:09 Voltage Offset Correction: v_off_ini = 675.862 uV, v_off_fin = 691.797 uV 15:03:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.633 uVs 15:03:09 Integrated Voltage Measurement... 15:03:18 Voltage Offset Correction: v_off_ini = 681.566 uV, v_off_fin = 673.218 uV 15:03:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -156.338 uVs 15:03:18 Integrated Voltage Measurement... 15:03:27 Voltage Offset Correction: v_off_ini = 684.349 uV, v_off_fin = 693.401 uV 15:03:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.855 uVs 15:03:27 Integrated Voltage Measurement... 15:03:36 Voltage Offset Correction: v_off_ini = 682.839 uV, v_off_fin = 662.921 uV 15:03:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -163.440 uVs 15:03:36 Integrated Voltage Measurement... 15:03:45 Voltage Offset Correction: v_off_ini = 674.402 uV, v_off_fin = 692.368 uV 15:03:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.401 uVs 15:03:49 I1Y Average and RMS of Measurements VT = -172.820 +- 4.741 uVs I1Y = -34.567 +- 0.950 uTm 15:03:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:57 Integrated Voltage Measurement... 15:04:06 Voltage Offset Correction: v_off_ini = 682.192 uV, v_off_fin = 684.365 uV 15:04:06 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -25.428 uVs 15:04:06 Integrated Voltage Measurement... 15:04:15 Voltage Offset Correction: v_off_ini = 687.037 uV, v_off_fin = 692.741 uV 15:04:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 35.901 uVs 15:04:15 Integrated Voltage Measurement... 15:04:24 Voltage Offset Correction: v_off_ini = 686.809 uV, v_off_fin = 685.103 uV 15:04:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -30.017 uVs 15:04:24 Integrated Voltage Measurement... 15:04:33 Voltage Offset Correction: v_off_ini = 701.846 uV, v_off_fin = 716.860 uV 15:04:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -3.162 uVs 15:04:33 Integrated Voltage Measurement... 15:04:42 Voltage Offset Correction: v_off_ini = 688.031 uV, v_off_fin = 678.781 uV 15:04:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -28.004 uVs 15:04:42 Integrated Voltage Measurement... 15:04:51 Voltage Offset Correction: v_off_ini = 690.676 uV, v_off_fin = 700.638 uV 15:04:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 16.170 uVs 15:04:53 I2X Average and RMS of Measurements VT = -22.060 +- 7.037 uVs I2X = 2.030 +- 0.647 uTm^2 15:04:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:01 Integrated Voltage Measurement... 15:05:10 Voltage Offset Correction: v_off_ini = 693.874 uV, v_off_fin = 687.977 uV 15:05:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.288 uVs 15:05:10 Integrated Voltage Measurement... 15:05:19 Voltage Offset Correction: v_off_ini = 689.829 uV, v_off_fin = 696.626 uV 15:05:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 164.336 uVs 15:05:20 Integrated Voltage Measurement... 15:05:28 Voltage Offset Correction: v_off_ini = 698.019 uV, v_off_fin = 683.789 uV 15:05:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.706 uVs 15:05:29 Integrated Voltage Measurement... 15:05:38 Voltage Offset Correction: v_off_ini = 708.112 uV, v_off_fin = 699.047 uV 15:05:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.644 uVs 15:05:38 Integrated Voltage Measurement... 15:05:47 Voltage Offset Correction: v_off_ini = 704.086 uV, v_off_fin = 691.589 uV 15:05:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -161.785 uVs 15:05:47 Integrated Voltage Measurement... 15:05:56 Voltage Offset Correction: v_off_ini = 701.836 uV, v_off_fin = 702.830 uV 15:05:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.946 uVs 15:05:58 I2Y Average and RMS of Measurements VT = -165.284 +- 1.249 uVs I2Y = -15.206 +- 0.115 uTm^2 15:06:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:16 Integrated Voltage Measurement... 15:06:25 Voltage Offset Correction: v_off_ini = 701.699 uV, v_off_fin = 705.088 uV 15:06:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -59.934 uVs 15:06:25 Integrated Voltage Measurement... 15:06:34 Voltage Offset Correction: v_off_ini = 703.126 uV, v_off_fin = 707.642 uV 15:06:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.480 uVs 15:06:34 Integrated Voltage Measurement... 15:06:43 Voltage Offset Correction: v_off_ini = 691.453 uV, v_off_fin = 695.814 uV 15:06:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.508 uVs 15:06:44 Integrated Voltage Measurement... 15:06:52 Voltage Offset Correction: v_off_ini = 693.579 uV, v_off_fin = 702.677 uV 15:06:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.029 uVs 15:06:53 Integrated Voltage Measurement... 15:07:02 Voltage Offset Correction: v_off_ini = 703.218 uV, v_off_fin = 705.030 uV 15:07:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.329 uVs 15:07:02 Integrated Voltage Measurement... 15:07:11 Voltage Offset Correction: v_off_ini = 703.957 uV, v_off_fin = 696.554 uV 15:07:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.671 uVs 15:07:15 I1X Average and RMS of Measurements VT = -53.658 +- 5.781 uVs I1X = 10.732 +- 1.156 uTm 15:07:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:22 Integrated Voltage Measurement... 15:07:31 Voltage Offset Correction: v_off_ini = 682.262 uV, v_off_fin = 669.070 uV 15:07:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.043 uVs 15:07:31 Integrated Voltage Measurement... 15:07:40 Voltage Offset Correction: v_off_ini = 692.630 uV, v_off_fin = 702.483 uV 15:07:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.479 uVs 15:07:40 Integrated Voltage Measurement... 15:07:49 Voltage Offset Correction: v_off_ini = 699.791 uV, v_off_fin = 686.076 uV 15:07:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.027 uVs 15:07:49 Integrated Voltage Measurement... 15:07:58 Voltage Offset Correction: v_off_ini = 693.953 uV, v_off_fin = 698.899 uV 15:07:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.807 uVs 15:07:58 Integrated Voltage Measurement... 15:08:07 Voltage Offset Correction: v_off_ini = 697.873 uV, v_off_fin = 675.386 uV 15:08:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -171.183 uVs 15:08:07 Integrated Voltage Measurement... 15:08:16 Voltage Offset Correction: v_off_ini = 701.104 uV, v_off_fin = 701.857 uV 15:08:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 172.675 uVs 15:08:20 I1Y Average and RMS of Measurements VT = -172.036 +- 1.902 uVs I1Y = -34.407 +- 0.380 uTm 15:08:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:28 Integrated Voltage Measurement... 15:08:37 Voltage Offset Correction: v_off_ini = 704.722 uV, v_off_fin = 697.951 uV 15:08:37 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -51.196 uVs 15:08:37 Integrated Voltage Measurement... 15:08:46 Voltage Offset Correction: v_off_ini = 701.838 uV, v_off_fin = 718.926 uV 15:08:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 45.699 uVs 15:08:46 Integrated Voltage Measurement... 15:08:55 Voltage Offset Correction: v_off_ini = 713.987 uV, v_off_fin = 709.588 uV 15:08:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -54.029 uVs 15:08:55 Integrated Voltage Measurement... 15:09:04 Voltage Offset Correction: v_off_ini = 719.000 uV, v_off_fin = 725.774 uV 15:09:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.975 uVs 15:09:04 Integrated Voltage Measurement... 15:09:13 Voltage Offset Correction: v_off_ini = 718.259 uV, v_off_fin = 719.570 uV 15:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.337 uVs 15:09:13 Integrated Voltage Measurement... 15:09:22 Voltage Offset Correction: v_off_ini = 719.569 uV, v_off_fin = 718.518 uV 15:09:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 33.959 uVs 15:09:24 I2X Average and RMS of Measurements VT = -45.866 +- 1.858 uVs I2X = 4.220 +- 0.171 uTm^2 15:09:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:32 Integrated Voltage Measurement... 15:09:41 Voltage Offset Correction: v_off_ini = 724.934 uV, v_off_fin = 717.798 uV 15:09:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -176.288 uVs 15:09:41 Integrated Voltage Measurement... 15:09:50 Voltage Offset Correction: v_off_ini = 714.061 uV, v_off_fin = 708.352 uV 15:09:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.710 uVs 15:09:50 Integrated Voltage Measurement... 15:09:59 Voltage Offset Correction: v_off_ini = 711.686 uV, v_off_fin = 717.346 uV 15:09:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -137.784 uVs 15:09:59 Integrated Voltage Measurement... 15:10:08 Voltage Offset Correction: v_off_ini = 723.626 uV, v_off_fin = 724.694 uV 15:10:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.530 uVs 15:10:08 Integrated Voltage Measurement... 15:10:17 Voltage Offset Correction: v_off_ini = 717.157 uV, v_off_fin = 719.155 uV 15:10:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.901 uVs 15:10:17 Integrated Voltage Measurement... 15:10:26 Voltage Offset Correction: v_off_ini = 717.845 uV, v_off_fin = 719.049 uV 15:10:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.324 uVs 15:10:29 I2Y Average and RMS of Measurements VT = -165.923 +- 10.801 uVs I2Y = -15.265 +- 0.994 uTm^2 15:10:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:47 Integrated Voltage Measurement... 15:10:56 Voltage Offset Correction: v_off_ini = 716.214 uV, v_off_fin = 708.322 uV 15:10:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -74.164 uVs 15:10:56 Integrated Voltage Measurement... 15:11:05 Voltage Offset Correction: v_off_ini = 705.560 uV, v_off_fin = 713.699 uV 15:11:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.295 uVs 15:11:05 Integrated Voltage Measurement... 15:11:14 Voltage Offset Correction: v_off_ini = 711.678 uV, v_off_fin = 708.808 uV 15:11:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.347 uVs 15:11:14 Integrated Voltage Measurement... 15:11:23 Voltage Offset Correction: v_off_ini = 708.005 uV, v_off_fin = 718.940 uV 15:11:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.353 uVs 15:11:23 Integrated Voltage Measurement... 15:11:32 Voltage Offset Correction: v_off_ini = 721.836 uV, v_off_fin = 725.399 uV 15:11:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -47.027 uVs 15:11:32 Integrated Voltage Measurement... 15:11:41 Voltage Offset Correction: v_off_ini = 729.499 uV, v_off_fin = 720.107 uV 15:11:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.060 uVs 15:11:46 I1X Average and RMS of Measurements VT = -56.541 +- 6.145 uVs I1X = 11.309 +- 1.230 uTm 15:11:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:52 Integrated Voltage Measurement... 15:12:01 Voltage Offset Correction: v_off_ini = 715.656 uV, v_off_fin = 708.333 uV 15:12:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -172.169 uVs 15:12:01 Integrated Voltage Measurement... 15:12:10 Voltage Offset Correction: v_off_ini = 727.924 uV, v_off_fin = 744.332 uV 15:12:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 180.667 uVs 15:12:10 Integrated Voltage Measurement... 15:12:19 Voltage Offset Correction: v_off_ini = 733.189 uV, v_off_fin = 709.059 uV 15:12:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.298 uVs 15:12:19 Integrated Voltage Measurement... 15:12:28 Voltage Offset Correction: v_off_ini = 721.711 uV, v_off_fin = 726.275 uV 15:12:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 171.126 uVs 15:12:28 Integrated Voltage Measurement... 15:12:37 Voltage Offset Correction: v_off_ini = 699.784 uV, v_off_fin = 697.724 uV 15:12:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.487 uVs 15:12:37 Integrated Voltage Measurement... 15:12:46 Voltage Offset Correction: v_off_ini = 716.047 uV, v_off_fin = 725.578 uV 15:12:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 158.839 uVs 15:12:51 I1Y Average and RMS of Measurements VT = -167.764 +- 7.045 uVs I1Y = -33.555 +- 1.410 uTm 15:12:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:12:58 Integrated Voltage Measurement... 15:13:07 Voltage Offset Correction: v_off_ini = 704.850 uV, v_off_fin = 701.436 uV 15:13:07 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -54.907 uVs 15:13:07 Integrated Voltage Measurement... 15:13:16 Voltage Offset Correction: v_off_ini = 694.806 uV, v_off_fin = 712.271 uV 15:13:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.812 uVs 15:13:16 Integrated Voltage Measurement... 15:13:25 Voltage Offset Correction: v_off_ini = 715.062 uV, v_off_fin = 705.138 uV 15:13:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.386 uVs 15:13:25 Integrated Voltage Measurement... 15:13:34 Voltage Offset Correction: v_off_ini = 716.716 uV, v_off_fin = 719.633 uV 15:13:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 28.793 uVs 15:13:35 Integrated Voltage Measurement... 15:13:43 Voltage Offset Correction: v_off_ini = 706.445 uV, v_off_fin = 690.036 uV 15:13:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -37.665 uVs 15:13:44 Integrated Voltage Measurement... 15:13:53 Voltage Offset Correction: v_off_ini = 706.528 uV, v_off_fin = 711.615 uV 15:13:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.090 uVs 15:13:55 I2X Average and RMS of Measurements VT = -41.109 +- 6.671 uVs I2X = 3.782 +- 0.613 uTm^2 15:14:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:03 Integrated Voltage Measurement... 15:14:12 Voltage Offset Correction: v_off_ini = 715.230 uV, v_off_fin = 714.253 uV 15:14:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.138 uVs 15:14:12 Integrated Voltage Measurement... 15:14:21 Voltage Offset Correction: v_off_ini = 719.879 uV, v_off_fin = 716.391 uV 15:14:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.084 uVs 15:14:21 Integrated Voltage Measurement... 15:14:30 Voltage Offset Correction: v_off_ini = 724.824 uV, v_off_fin = 721.332 uV 15:14:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -169.336 uVs 15:14:30 Integrated Voltage Measurement... 15:14:39 Voltage Offset Correction: v_off_ini = 720.498 uV, v_off_fin = 712.166 uV 15:14:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 165.148 uVs 15:14:39 Integrated Voltage Measurement... 15:14:48 Voltage Offset Correction: v_off_ini = 708.822 uV, v_off_fin = 716.762 uV 15:14:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -158.690 uVs 15:14:48 Integrated Voltage Measurement... 15:14:57 Voltage Offset Correction: v_off_ini = 717.657 uV, v_off_fin = 725.713 uV 15:14:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.176 uVs 15:14:59 I2Y Average and RMS of Measurements VT = -164.929 +- 1.891 uVs I2Y = -15.173 +- 0.174 uTm^2 15:15:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm