SLAC Magnetic Measurements Date: 01-14-2022 Time: 11:45:27 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: SXU_1M_PROTOTYPE DATASET Number: 1 Tuning Stage: Tuning Run Number: 80 Measurement Type: Long Coil Scans Operator: YL Comment: Cross-talk test; 7.2mm/35mm gaps, 20 cm distance Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 -8.242E-06 -109.870E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1Y_VS_X 0.000E-03 -9.377E-06 -125.005E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1Y_VS_X 0.000E-03 -8.715E-06 -116.179E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_X 0.000E-03 3.899E-06 51.977E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1X_VS_X 0.000E-03 4.794E-06 63.913E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1X_VS_X 0.000E-03 4.629E-06 61.712E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0