SLAC Magnetic Measurements Date: 02-12-2025 Time: 13:45:01 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10090 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 1 Measurement Device: Operator: YL Comment: 13:45:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:11 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:45:13 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:45:14 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:45:16 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:45:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:38 Integrated Voltage Measurement... 13:45:47 Voltage Offset Correction: v_off_ini = 273.203 uV, v_off_fin = 273.985 uV 13:45:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.275 uVs 13:45:47 Integrated Voltage Measurement... 13:45:56 Voltage Offset Correction: v_off_ini = 268.209 uV, v_off_fin = 258.498 uV 13:45:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.546 uVs 13:45:56 Integrated Voltage Measurement... 13:46:05 Voltage Offset Correction: v_off_ini = 264.847 uV, v_off_fin = 262.379 uV 13:46:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.493 uVs 13:46:05 Integrated Voltage Measurement... 13:46:14 Voltage Offset Correction: v_off_ini = 262.097 uV, v_off_fin = 269.124 uV 13:46:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.497 uVs 13:46:14 Integrated Voltage Measurement... 13:46:23 Voltage Offset Correction: v_off_ini = 270.676 uV, v_off_fin = 263.507 uV 13:46:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.125 uVs 13:46:23 Integrated Voltage Measurement... 13:46:32 Voltage Offset Correction: v_off_ini = 269.494 uV, v_off_fin = 269.187 uV 13:46:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.309 uVs 13:46:37 I1X Average and RMS of Measurements VT = -61.541 +- 2.439 uVs I1X = 12.308 +- 0.488 uTm 13:46:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:43 Integrated Voltage Measurement... 13:46:52 Voltage Offset Correction: v_off_ini = 271.607 uV, v_off_fin = 268.037 uV 13:46:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.139 uVs 13:46:52 Integrated Voltage Measurement... 13:47:01 Voltage Offset Correction: v_off_ini = 302.737 uV, v_off_fin = 295.757 uV 13:47:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.399 uVs 13:47:01 Integrated Voltage Measurement... 13:47:10 Voltage Offset Correction: v_off_ini = 280.182 uV, v_off_fin = 271.792 uV 13:47:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.022 uVs 13:47:10 Integrated Voltage Measurement... 13:47:19 Voltage Offset Correction: v_off_ini = 285.528 uV, v_off_fin = 297.872 uV 13:47:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.880 uVs 13:47:19 Integrated Voltage Measurement... 13:47:28 Voltage Offset Correction: v_off_ini = 297.105 uV, v_off_fin = 277.821 uV 13:47:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.812 uVs 13:47:28 Integrated Voltage Measurement... 13:47:37 Voltage Offset Correction: v_off_ini = 306.010 uV, v_off_fin = 303.859 uV 13:47:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.186 uVs 13:47:42 I1Y Average and RMS of Measurements VT = -234.906 +- 3.284 uVs I1Y = -46.981 +- 0.657 uTm 13:47:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:47:49 Integrated Voltage Measurement... 13:47:58 Voltage Offset Correction: v_off_ini = 270.414 uV, v_off_fin = 278.860 uV 13:47:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -61.660 uVs 13:47:58 Integrated Voltage Measurement... 13:48:07 Voltage Offset Correction: v_off_ini = 287.036 uV, v_off_fin = 283.763 uV 13:48:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.050 uVs 13:48:07 Integrated Voltage Measurement... 13:48:16 Voltage Offset Correction: v_off_ini = 302.519 uV, v_off_fin = 281.989 uV 13:48:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.175 uVs 13:48:16 Integrated Voltage Measurement... 13:48:25 Voltage Offset Correction: v_off_ini = 303.278 uV, v_off_fin = 298.720 uV 13:48:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.536 uVs 13:48:26 Integrated Voltage Measurement... 13:48:35 Voltage Offset Correction: v_off_ini = 313.290 uV, v_off_fin = 290.208 uV 13:48:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.779 uVs 13:48:35 Integrated Voltage Measurement... 13:48:44 Voltage Offset Correction: v_off_ini = 292.730 uV, v_off_fin = 300.040 uV 13:48:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.099 uVs 13:48:46 I2X Average and RMS of Measurements VT = -65.716 +- 5.922 uVs I2X = 6.046 +- 0.545 uTm^2 13:48:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:54 Integrated Voltage Measurement... 13:49:03 Voltage Offset Correction: v_off_ini = 331.566 uV, v_off_fin = 323.832 uV 13:49:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.024 uVs 13:49:03 Integrated Voltage Measurement... 13:49:12 Voltage Offset Correction: v_off_ini = 321.653 uV, v_off_fin = 320.974 uV 13:49:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.778 uVs 13:49:12 Integrated Voltage Measurement... 13:49:21 Voltage Offset Correction: v_off_ini = 315.128 uV, v_off_fin = 328.417 uV 13:49:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.866 uVs 13:49:21 Integrated Voltage Measurement... 13:49:30 Voltage Offset Correction: v_off_ini = 310.764 uV, v_off_fin = 316.712 uV 13:49:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.231 uVs 13:49:30 Integrated Voltage Measurement... 13:49:39 Voltage Offset Correction: v_off_ini = 302.625 uV, v_off_fin = 326.456 uV 13:49:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.853 uVs 13:49:39 Integrated Voltage Measurement... 13:49:48 Voltage Offset Correction: v_off_ini = 317.742 uV, v_off_fin = 318.836 uV 13:49:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.491 uVs 13:49:50 I2Y Average and RMS of Measurements VT = -261.040 +- 12.659 uVs I2Y = -24.016 +- 1.165 uTm^2 13:50:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:50:04 Integrated Voltage Measurement... 13:50:13 Voltage Offset Correction: v_off_ini = 334.209 uV, v_off_fin = 331.488 uV 13:50:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.608 uVs 13:50:13 Integrated Voltage Measurement... 13:50:22 Voltage Offset Correction: v_off_ini = 345.826 uV, v_off_fin = 345.839 uV 13:50:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.286 uVs 13:50:22 Integrated Voltage Measurement... 13:50:31 Voltage Offset Correction: v_off_ini = 344.819 uV, v_off_fin = 349.922 uV 13:50:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.000 uVs 13:50:31 Integrated Voltage Measurement... 13:50:40 Voltage Offset Correction: v_off_ini = 338.205 uV, v_off_fin = 319.150 uV 13:50:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.996 uVs 13:50:40 Integrated Voltage Measurement... 13:50:49 Voltage Offset Correction: v_off_ini = 327.603 uV, v_off_fin = 336.224 uV 13:50:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.132 uVs 13:50:49 Integrated Voltage Measurement... 13:50:58 Voltage Offset Correction: v_off_ini = 325.903 uV, v_off_fin = 333.399 uV 13:50:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.427 uVs 13:51:03 I1X Average and RMS of Measurements VT = -83.741 +- 3.567 uVs I1X = 16.749 +- 0.713 uTm 13:51:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:09 Integrated Voltage Measurement... 13:51:18 Voltage Offset Correction: v_off_ini = 332.774 uV, v_off_fin = 314.883 uV 13:51:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.271 uVs 13:51:18 Integrated Voltage Measurement... 13:51:27 Voltage Offset Correction: v_off_ini = 331.087 uV, v_off_fin = 342.302 uV 13:51:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.549 uVs 13:51:27 Integrated Voltage Measurement... 13:51:36 Voltage Offset Correction: v_off_ini = 321.113 uV, v_off_fin = 313.053 uV 13:51:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.578 uVs 13:51:36 Integrated Voltage Measurement... 13:51:45 Voltage Offset Correction: v_off_ini = 334.810 uV, v_off_fin = 340.308 uV 13:51:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.374 uVs 13:51:45 Integrated Voltage Measurement... 13:51:54 Voltage Offset Correction: v_off_ini = 345.412 uV, v_off_fin = 326.794 uV 13:51:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.079 uVs 13:51:54 Integrated Voltage Measurement... 13:52:03 Voltage Offset Correction: v_off_ini = 321.796 uV, v_off_fin = 346.870 uV 13:52:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.057 uVs 13:52:08 I1Y Average and RMS of Measurements VT = -234.985 +- 6.920 uVs I1Y = -46.997 +- 1.384 uTm 13:52:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:15 Integrated Voltage Measurement... 13:52:24 Voltage Offset Correction: v_off_ini = 329.285 uV, v_off_fin = 320.585 uV 13:52:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.447 uVs 13:52:24 Integrated Voltage Measurement... 13:52:33 Voltage Offset Correction: v_off_ini = 327.197 uV, v_off_fin = 318.567 uV 13:52:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.546 uVs 13:52:33 Integrated Voltage Measurement... 13:52:42 Voltage Offset Correction: v_off_ini = 335.312 uV, v_off_fin = 324.020 uV 13:52:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.026 uVs 13:52:43 Integrated Voltage Measurement... 13:52:52 Voltage Offset Correction: v_off_ini = 341.560 uV, v_off_fin = 340.151 uV 13:52:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.136 uVs 13:52:52 Integrated Voltage Measurement... 13:53:01 Voltage Offset Correction: v_off_ini = 318.375 uV, v_off_fin = 318.994 uV 13:53:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.330 uVs 13:53:01 Integrated Voltage Measurement... 13:53:10 Voltage Offset Correction: v_off_ini = 328.686 uV, v_off_fin = 340.215 uV 13:53:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.694 uVs 13:53:12 I2X Average and RMS of Measurements VT = -71.030 +- 4.590 uVs I2X = 6.535 +- 0.422 uTm^2 13:53:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:20 Integrated Voltage Measurement... 13:53:29 Voltage Offset Correction: v_off_ini = 332.522 uV, v_off_fin = 326.353 uV 13:53:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.424 uVs 13:53:29 Integrated Voltage Measurement... 13:53:38 Voltage Offset Correction: v_off_ini = 320.804 uV, v_off_fin = 318.762 uV 13:53:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.389 uVs 13:53:38 Integrated Voltage Measurement... 13:53:47 Voltage Offset Correction: v_off_ini = 337.791 uV, v_off_fin = 333.128 uV 13:53:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.192 uVs 13:53:47 Integrated Voltage Measurement... 13:53:56 Voltage Offset Correction: v_off_ini = 324.986 uV, v_off_fin = 336.521 uV 13:53:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.702 uVs 13:53:56 Integrated Voltage Measurement... 13:54:05 Voltage Offset Correction: v_off_ini = 346.373 uV, v_off_fin = 337.869 uV 13:54:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.793 uVs 13:54:05 Integrated Voltage Measurement... 13:54:14 Voltage Offset Correction: v_off_ini = 343.428 uV, v_off_fin = 344.842 uV 13:54:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.177 uVs 13:54:16 I2Y Average and RMS of Measurements VT = -248.446 +- 8.010 uVs I2Y = -22.857 +- 0.737 uTm^2 13:54:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:30 Integrated Voltage Measurement... 13:54:39 Voltage Offset Correction: v_off_ini = 359.820 uV, v_off_fin = 357.654 uV 13:54:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.658 uVs 13:54:39 Integrated Voltage Measurement... 13:54:48 Voltage Offset Correction: v_off_ini = 362.322 uV, v_off_fin = 369.982 uV 13:54:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.391 uVs 13:54:48 Integrated Voltage Measurement... 13:54:57 Voltage Offset Correction: v_off_ini = 368.096 uV, v_off_fin = 370.843 uV 13:54:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.554 uVs 13:54:57 Integrated Voltage Measurement... 13:55:06 Voltage Offset Correction: v_off_ini = 373.428 uV, v_off_fin = 370.053 uV 13:55:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.327 uVs 13:55:06 Integrated Voltage Measurement... 13:55:15 Voltage Offset Correction: v_off_ini = 374.126 uV, v_off_fin = 379.881 uV 13:55:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.417 uVs 13:55:15 Integrated Voltage Measurement... 13:55:24 Voltage Offset Correction: v_off_ini = 382.813 uV, v_off_fin = 375.884 uV 13:55:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.037 uVs 13:55:29 I1X Average and RMS of Measurements VT = -87.231 +- 6.973 uVs I1X = 17.446 +- 1.395 uTm 13:55:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:35 Integrated Voltage Measurement... 13:55:44 Voltage Offset Correction: v_off_ini = 371.436 uV, v_off_fin = 369.153 uV 13:55:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.938 uVs 13:55:44 Integrated Voltage Measurement... 13:55:53 Voltage Offset Correction: v_off_ini = 381.004 uV, v_off_fin = 390.792 uV 13:55:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.986 uVs 13:55:53 Integrated Voltage Measurement... 13:56:02 Voltage Offset Correction: v_off_ini = 378.670 uV, v_off_fin = 371.747 uV 13:56:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.106 uVs 13:56:02 Integrated Voltage Measurement... 13:56:11 Voltage Offset Correction: v_off_ini = 370.998 uV, v_off_fin = 379.470 uV 13:56:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.996 uVs 13:56:11 Integrated Voltage Measurement... 13:56:20 Voltage Offset Correction: v_off_ini = 375.994 uV, v_off_fin = 358.833 uV 13:56:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.338 uVs 13:56:20 Integrated Voltage Measurement... 13:56:29 Voltage Offset Correction: v_off_ini = 364.097 uV, v_off_fin = 380.634 uV 13:56:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.395 uVs 13:56:33 I1Y Average and RMS of Measurements VT = -230.460 +- 3.621 uVs I1Y = -46.092 +- 0.724 uTm 13:56:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:41 Integrated Voltage Measurement... 13:56:50 Voltage Offset Correction: v_off_ini = 363.449 uV, v_off_fin = 371.848 uV 13:56:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.975 uVs 13:56:50 Integrated Voltage Measurement... 13:56:59 Voltage Offset Correction: v_off_ini = 384.736 uV, v_off_fin = 365.991 uV 13:56:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.373 uVs 13:56:59 Integrated Voltage Measurement... 13:57:08 Voltage Offset Correction: v_off_ini = 375.450 uV, v_off_fin = 371.345 uV 13:57:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.587 uVs 13:57:08 Integrated Voltage Measurement... 13:57:17 Voltage Offset Correction: v_off_ini = 362.484 uV, v_off_fin = 385.122 uV 13:57:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.773 uVs 13:57:17 Integrated Voltage Measurement... 13:57:26 Voltage Offset Correction: v_off_ini = 362.204 uV, v_off_fin = 370.677 uV 13:57:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.738 uVs 13:57:26 Integrated Voltage Measurement... 13:57:35 Voltage Offset Correction: v_off_ini = 374.717 uV, v_off_fin = 390.319 uV 13:57:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.353 uVs 13:57:38 I2X Average and RMS of Measurements VT = -89.800 +- 3.362 uVs I2X = 8.262 +- 0.309 uTm^2 13:57:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:45 Integrated Voltage Measurement... 13:57:54 Voltage Offset Correction: v_off_ini = 397.253 uV, v_off_fin = 393.919 uV 13:57:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.934 uVs 13:57:54 Integrated Voltage Measurement... 13:58:03 Voltage Offset Correction: v_off_ini = 393.684 uV, v_off_fin = 408.437 uV 13:58:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.838 uVs 13:58:03 Integrated Voltage Measurement... 13:58:12 Voltage Offset Correction: v_off_ini = 387.476 uV, v_off_fin = 384.672 uV 13:58:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.694 uVs 13:58:12 Integrated Voltage Measurement... 13:58:21 Voltage Offset Correction: v_off_ini = 400.941 uV, v_off_fin = 389.247 uV 13:58:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.575 uVs 13:58:21 Integrated Voltage Measurement... 13:58:30 Voltage Offset Correction: v_off_ini = 378.735 uV, v_off_fin = 367.855 uV 13:58:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.120 uVs 13:58:30 Integrated Voltage Measurement... 13:58:39 Voltage Offset Correction: v_off_ini = 369.667 uV, v_off_fin = 362.767 uV 13:58:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.735 uVs 13:58:42 I2Y Average and RMS of Measurements VT = -245.816 +- 11.944 uVs I2Y = -22.615 +- 1.099 uTm^2 13:58:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:56 Integrated Voltage Measurement... 13:59:05 Voltage Offset Correction: v_off_ini = 375.362 uV, v_off_fin = 383.554 uV 13:59:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.868 uVs 13:59:05 Integrated Voltage Measurement... 13:59:14 Voltage Offset Correction: v_off_ini = 360.662 uV, v_off_fin = 379.050 uV 13:59:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.388 uVs 13:59:14 Integrated Voltage Measurement... 13:59:23 Voltage Offset Correction: v_off_ini = 394.461 uV, v_off_fin = 396.484 uV 13:59:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.494 uVs 13:59:23 Integrated Voltage Measurement... 13:59:31 Voltage Offset Correction: v_off_ini = 387.990 uV, v_off_fin = 389.842 uV 13:59:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.596 uVs 13:59:32 Integrated Voltage Measurement... 13:59:40 Voltage Offset Correction: v_off_ini = 383.126 uV, v_off_fin = 372.758 uV 13:59:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.513 uVs 13:59:41 Integrated Voltage Measurement... 13:59:49 Voltage Offset Correction: v_off_ini = 380.356 uV, v_off_fin = 388.838 uV 13:59:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.771 uVs 13:59:54 I1X Average and RMS of Measurements VT = -101.605 +- 9.888 uVs I1X = 20.321 +- 1.978 uTm 13:59:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:00 Integrated Voltage Measurement... 14:00:09 Voltage Offset Correction: v_off_ini = 387.122 uV, v_off_fin = 356.143 uV 14:00:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.111 uVs 14:00:09 Integrated Voltage Measurement... 14:00:18 Voltage Offset Correction: v_off_ini = 359.569 uV, v_off_fin = 357.373 uV 14:00:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.441 uVs 14:00:18 Integrated Voltage Measurement... 14:00:27 Voltage Offset Correction: v_off_ini = 350.385 uV, v_off_fin = 344.565 uV 14:00:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.257 uVs 14:00:27 Integrated Voltage Measurement... 14:00:36 Voltage Offset Correction: v_off_ini = 371.655 uV, v_off_fin = 380.683 uV 14:00:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.532 uVs 14:00:36 Integrated Voltage Measurement... 14:00:45 Voltage Offset Correction: v_off_ini = 368.350 uV, v_off_fin = 353.102 uV 14:00:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.814 uVs 14:00:45 Integrated Voltage Measurement... 14:00:54 Voltage Offset Correction: v_off_ini = 351.361 uV, v_off_fin = 356.169 uV 14:00:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.608 uVs 14:00:58 I1Y Average and RMS of Measurements VT = -227.627 +- 5.675 uVs I1Y = -45.526 +- 1.134 uTm 14:01:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:06 Integrated Voltage Measurement... 14:01:15 Voltage Offset Correction: v_off_ini = 334.911 uV, v_off_fin = 338.398 uV 14:01:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.200 uVs 14:01:15 Integrated Voltage Measurement... 14:01:24 Voltage Offset Correction: v_off_ini = 340.366 uV, v_off_fin = 345.100 uV 14:01:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.482 uVs 14:01:24 Integrated Voltage Measurement... 14:01:33 Voltage Offset Correction: v_off_ini = 350.191 uV, v_off_fin = 326.615 uV 14:01:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.793 uVs 14:01:33 Integrated Voltage Measurement... 14:01:42 Voltage Offset Correction: v_off_ini = 337.597 uV, v_off_fin = 334.610 uV 14:01:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.985 uVs 14:01:42 Integrated Voltage Measurement... 14:01:51 Voltage Offset Correction: v_off_ini = 324.939 uV, v_off_fin = 331.162 uV 14:01:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.027 uVs 14:01:51 Integrated Voltage Measurement... 14:02:00 Voltage Offset Correction: v_off_ini = 351.328 uV, v_off_fin = 373.927 uV 14:02:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.329 uVs 14:02:03 I2X Average and RMS of Measurements VT = -104.469 +- 15.164 uVs I2X = 9.611 +- 1.395 uTm^2 14:02:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:10 Integrated Voltage Measurement... 14:02:19 Voltage Offset Correction: v_off_ini = 347.461 uV, v_off_fin = 347.906 uV 14:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.475 uVs 14:02:19 Integrated Voltage Measurement... 14:02:28 Voltage Offset Correction: v_off_ini = 367.946 uV, v_off_fin = 371.444 uV 14:02:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.335 uVs 14:02:28 Integrated Voltage Measurement... 14:02:37 Voltage Offset Correction: v_off_ini = 369.453 uV, v_off_fin = 370.800 uV 14:02:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.612 uVs 14:02:37 Integrated Voltage Measurement... 14:02:46 Voltage Offset Correction: v_off_ini = 376.784 uV, v_off_fin = 380.193 uV 14:02:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.379 uVs 14:02:46 Integrated Voltage Measurement... 14:02:55 Voltage Offset Correction: v_off_ini = 367.623 uV, v_off_fin = 355.870 uV 14:02:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.556 uVs 14:02:55 Integrated Voltage Measurement... 14:03:04 Voltage Offset Correction: v_off_ini = 354.244 uV, v_off_fin = 348.582 uV 14:03:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.216 uVs 14:03:07 I2Y Average and RMS of Measurements VT = -243.096 +- 8.894 uVs I2Y = -22.365 +- 0.818 uTm^2 14:03:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:03:21 Integrated Voltage Measurement... 14:03:30 Voltage Offset Correction: v_off_ini = 340.490 uV, v_off_fin = 352.206 uV 14:03:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.879 uVs 14:03:30 Integrated Voltage Measurement... 14:03:39 Voltage Offset Correction: v_off_ini = 349.779 uV, v_off_fin = 340.887 uV 14:03:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.617 uVs 14:03:39 Integrated Voltage Measurement... 14:03:48 Voltage Offset Correction: v_off_ini = 366.447 uV, v_off_fin = 365.466 uV 14:03:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.172 uVs 14:03:48 Integrated Voltage Measurement... 14:03:57 Voltage Offset Correction: v_off_ini = 356.357 uV, v_off_fin = 352.425 uV 14:03:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.183 uVs 14:03:57 Integrated Voltage Measurement... 14:04:06 Voltage Offset Correction: v_off_ini = 375.711 uV, v_off_fin = 359.154 uV 14:04:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.306 uVs 14:04:06 Integrated Voltage Measurement... 14:04:15 Voltage Offset Correction: v_off_ini = 353.139 uV, v_off_fin = 375.231 uV 14:04:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.098 uVs 14:04:19 I1X Average and RMS of Measurements VT = -112.709 +- 8.216 uVs I1X = 22.542 +- 1.643 uTm 14:04:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:26 Integrated Voltage Measurement... 14:04:35 Voltage Offset Correction: v_off_ini = 368.963 uV, v_off_fin = 358.217 uV 14:04:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -222.829 uVs 14:04:35 Integrated Voltage Measurement... 14:04:43 Voltage Offset Correction: v_off_ini = 376.056 uV, v_off_fin = 392.718 uV 14:04:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.419 uVs 14:04:44 Integrated Voltage Measurement... 14:04:52 Voltage Offset Correction: v_off_ini = 382.291 uV, v_off_fin = 374.762 uV 14:04:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -244.233 uVs 14:04:53 Integrated Voltage Measurement... 14:05:01 Voltage Offset Correction: v_off_ini = 381.165 uV, v_off_fin = 387.341 uV 14:05:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.342 uVs 14:05:02 Integrated Voltage Measurement... 14:05:10 Voltage Offset Correction: v_off_ini = 382.893 uV, v_off_fin = 382.575 uV 14:05:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.537 uVs 14:05:10 Integrated Voltage Measurement... 14:05:19 Voltage Offset Correction: v_off_ini = 396.351 uV, v_off_fin = 401.954 uV 14:05:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.271 uVs 14:05:24 I1Y Average and RMS of Measurements VT = -224.605 +- 4.766 uVs I1Y = -44.919 +- 0.951 uTm 14:05:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:31 Integrated Voltage Measurement... 14:05:40 Voltage Offset Correction: v_off_ini = 395.382 uV, v_off_fin = 373.811 uV 14:05:40 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -110.630 uVs 14:05:40 Integrated Voltage Measurement... 14:05:49 Voltage Offset Correction: v_off_ini = 393.720 uV, v_off_fin = 394.864 uV 14:05:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.240 uVs 14:05:49 Integrated Voltage Measurement... 14:05:58 Voltage Offset Correction: v_off_ini = 374.768 uV, v_off_fin = 397.519 uV 14:05:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.587 uVs 14:05:58 Integrated Voltage Measurement... 14:06:07 Voltage Offset Correction: v_off_ini = 409.672 uV, v_off_fin = 410.922 uV 14:06:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.238 uVs 14:06:07 Integrated Voltage Measurement... 14:06:16 Voltage Offset Correction: v_off_ini = 402.510 uV, v_off_fin = 412.436 uV 14:06:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.426 uVs 14:06:16 Integrated Voltage Measurement... 14:06:25 Voltage Offset Correction: v_off_ini = 428.699 uV, v_off_fin = 427.778 uV 14:06:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.146 uVs 14:06:28 I2X Average and RMS of Measurements VT = -98.545 +- 4.072 uVs I2X = 9.066 +- 0.374 uTm^2 14:06:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:35 Integrated Voltage Measurement... 14:06:44 Voltage Offset Correction: v_off_ini = 411.213 uV, v_off_fin = 421.111 uV 14:06:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.787 uVs 14:06:44 Integrated Voltage Measurement... 14:06:53 Voltage Offset Correction: v_off_ini = 413.209 uV, v_off_fin = 399.264 uV 14:06:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.339 uVs 14:06:53 Integrated Voltage Measurement... 14:07:02 Voltage Offset Correction: v_off_ini = 401.685 uV, v_off_fin = 413.966 uV 14:07:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.046 uVs 14:07:02 Integrated Voltage Measurement... 14:07:11 Voltage Offset Correction: v_off_ini = 418.393 uV, v_off_fin = 419.515 uV 14:07:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.857 uVs 14:07:12 Integrated Voltage Measurement... 14:07:20 Voltage Offset Correction: v_off_ini = 414.809 uV, v_off_fin = 415.258 uV 14:07:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.296 uVs 14:07:21 Integrated Voltage Measurement... 14:07:29 Voltage Offset Correction: v_off_ini = 442.636 uV, v_off_fin = 435.484 uV 14:07:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.244 uVs 14:07:32 I2Y Average and RMS of Measurements VT = -237.261 +- 11.961 uVs I2Y = -21.828 +- 1.100 uTm^2 14:07:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:07:46 Integrated Voltage Measurement... 14:07:55 Voltage Offset Correction: v_off_ini = 435.060 uV, v_off_fin = 415.210 uV 14:07:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.042 uVs 14:07:55 Integrated Voltage Measurement... 14:08:04 Voltage Offset Correction: v_off_ini = 415.942 uV, v_off_fin = 408.437 uV 14:08:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.430 uVs 14:08:04 Integrated Voltage Measurement... 14:08:13 Voltage Offset Correction: v_off_ini = 428.197 uV, v_off_fin = 425.358 uV 14:08:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.137 uVs 14:08:13 Integrated Voltage Measurement... 14:08:22 Voltage Offset Correction: v_off_ini = 429.220 uV, v_off_fin = 420.522 uV 14:08:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.582 uVs 14:08:22 Integrated Voltage Measurement... 14:08:31 Voltage Offset Correction: v_off_ini = 419.569 uV, v_off_fin = 425.124 uV 14:08:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.326 uVs 14:08:31 Integrated Voltage Measurement... 14:08:40 Voltage Offset Correction: v_off_ini = 415.085 uV, v_off_fin = 413.555 uV 14:08:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.232 uVs 14:08:44 I1X Average and RMS of Measurements VT = -117.958 +- 8.353 uVs I1X = 23.592 +- 1.671 uTm 14:08:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:51 Integrated Voltage Measurement... 14:09:00 Voltage Offset Correction: v_off_ini = 416.975 uV, v_off_fin = 409.452 uV 14:09:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.409 uVs 14:09:00 Integrated Voltage Measurement... 14:09:09 Voltage Offset Correction: v_off_ini = 421.656 uV, v_off_fin = 433.726 uV 14:09:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.529 uVs 14:09:09 Integrated Voltage Measurement... 14:09:18 Voltage Offset Correction: v_off_ini = 409.026 uV, v_off_fin = 421.798 uV 14:09:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -234.098 uVs 14:09:18 Integrated Voltage Measurement... 14:09:27 Voltage Offset Correction: v_off_ini = 424.190 uV, v_off_fin = 437.586 uV 14:09:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.508 uVs 14:09:27 Integrated Voltage Measurement... 14:09:36 Voltage Offset Correction: v_off_ini = 440.620 uV, v_off_fin = 416.318 uV 14:09:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -242.906 uVs 14:09:36 Integrated Voltage Measurement... 14:09:45 Voltage Offset Correction: v_off_ini = 434.092 uV, v_off_fin = 455.851 uV 14:09:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.386 uVs 14:09:49 I1Y Average and RMS of Measurements VT = -230.306 +- 8.680 uVs I1Y = -46.057 +- 1.737 uTm 14:09:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:57 Integrated Voltage Measurement... 14:10:06 Voltage Offset Correction: v_off_ini = 460.427 uV, v_off_fin = 451.366 uV 14:10:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -124.526 uVs 14:10:06 Integrated Voltage Measurement... 14:10:15 Voltage Offset Correction: v_off_ini = 462.982 uV, v_off_fin = 474.542 uV 14:10:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.512 uVs 14:10:15 Integrated Voltage Measurement... 14:10:24 Voltage Offset Correction: v_off_ini = 473.791 uV, v_off_fin = 460.141 uV 14:10:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.572 uVs 14:10:24 Integrated Voltage Measurement... 14:10:33 Voltage Offset Correction: v_off_ini = 484.905 uV, v_off_fin = 474.483 uV 14:10:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.815 uVs 14:10:33 Integrated Voltage Measurement... 14:10:42 Voltage Offset Correction: v_off_ini = 477.287 uV, v_off_fin = 465.815 uV 14:10:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.660 uVs 14:10:42 Integrated Voltage Measurement... 14:10:51 Voltage Offset Correction: v_off_ini = 502.016 uV, v_off_fin = 517.100 uV 14:10:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.361 uVs 14:10:53 I2X Average and RMS of Measurements VT = -111.074 +- 14.553 uVs I2X = 10.219 +- 1.339 uTm^2 14:10:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:01 Integrated Voltage Measurement... 14:11:10 Voltage Offset Correction: v_off_ini = 451.064 uV, v_off_fin = 465.111 uV 14:11:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.931 uVs 14:11:10 Integrated Voltage Measurement... 14:11:19 Voltage Offset Correction: v_off_ini = 460.967 uV, v_off_fin = 453.875 uV 14:11:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.174 uVs 14:11:19 Integrated Voltage Measurement... 14:11:28 Voltage Offset Correction: v_off_ini = 486.561 uV, v_off_fin = 480.132 uV 14:11:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.576 uVs 14:11:28 Integrated Voltage Measurement... 14:11:37 Voltage Offset Correction: v_off_ini = 487.528 uV, v_off_fin = 513.795 uV 14:11:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.534 uVs 14:11:37 Integrated Voltage Measurement... 14:11:46 Voltage Offset Correction: v_off_ini = 503.179 uV, v_off_fin = 492.862 uV 14:11:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.452 uVs 14:11:46 Integrated Voltage Measurement... 14:11:55 Voltage Offset Correction: v_off_ini = 502.133 uV, v_off_fin = 501.640 uV 14:11:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 264.922 uVs 14:11:57 I2Y Average and RMS of Measurements VT = -234.765 +- 9.631 uVs I2Y = -21.599 +- 0.887 uTm^2 14:12:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:12:11 Integrated Voltage Measurement... 14:12:20 Voltage Offset Correction: v_off_ini = 511.716 uV, v_off_fin = 521.795 uV 14:12:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.068 uVs 14:12:20 Integrated Voltage Measurement... 14:12:29 Voltage Offset Correction: v_off_ini = 532.745 uV, v_off_fin = 518.511 uV 14:12:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.097 uVs 14:12:29 Integrated Voltage Measurement... 14:12:38 Voltage Offset Correction: v_off_ini = 514.755 uV, v_off_fin = 521.540 uV 14:12:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.684 uVs 14:12:38 Integrated Voltage Measurement... 14:12:47 Voltage Offset Correction: v_off_ini = 533.723 uV, v_off_fin = 517.128 uV 14:12:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.825 uVs 14:12:48 Integrated Voltage Measurement... 14:12:56 Voltage Offset Correction: v_off_ini = 524.929 uV, v_off_fin = 533.422 uV 14:12:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.951 uVs 14:12:57 Integrated Voltage Measurement... 14:13:05 Voltage Offset Correction: v_off_ini = 538.187 uV, v_off_fin = 533.107 uV 14:13:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.514 uVs 14:13:10 I1X Average and RMS of Measurements VT = -110.357 +- 9.872 uVs I1X = 22.071 +- 1.974 uTm 14:13:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:13:17 Integrated Voltage Measurement... 14:13:25 Voltage Offset Correction: v_off_ini = 524.542 uV, v_off_fin = 513.859 uV 14:13:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -222.000 uVs 14:13:26 Integrated Voltage Measurement... 14:13:34 Voltage Offset Correction: v_off_ini = 515.720 uV, v_off_fin = 527.101 uV 14:13:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.640 uVs 14:13:35 Integrated Voltage Measurement... 14:13:43 Voltage Offset Correction: v_off_ini = 525.635 uV, v_off_fin = 506.278 uV 14:13:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.042 uVs 14:13:44 Integrated Voltage Measurement... 14:13:52 Voltage Offset Correction: v_off_ini = 549.982 uV, v_off_fin = 573.063 uV 14:13:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.164 uVs 14:13:53 Integrated Voltage Measurement... 14:14:01 Voltage Offset Correction: v_off_ini = 545.526 uV, v_off_fin = 525.067 uV 14:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.349 uVs 14:14:02 Integrated Voltage Measurement... 14:14:11 Voltage Offset Correction: v_off_ini = 514.856 uV, v_off_fin = 538.701 uV 14:14:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.563 uVs 14:14:15 I1Y Average and RMS of Measurements VT = -219.960 +- 8.237 uVs I1Y = -43.990 +- 1.646 uTm 14:14:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:23 Integrated Voltage Measurement... 14:14:32 Voltage Offset Correction: v_off_ini = 533.578 uV, v_off_fin = 524.719 uV 14:14:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.683 uVs 14:14:32 Integrated Voltage Measurement... 14:14:41 Voltage Offset Correction: v_off_ini = 533.698 uV, v_off_fin = 533.056 uV 14:14:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.305 uVs 14:14:41 Integrated Voltage Measurement... 14:14:50 Voltage Offset Correction: v_off_ini = 535.962 uV, v_off_fin = 516.858 uV 14:14:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.072 uVs 14:14:50 Integrated Voltage Measurement... 14:14:59 Voltage Offset Correction: v_off_ini = 515.019 uV, v_off_fin = 519.539 uV 14:14:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.844 uVs 14:14:59 Integrated Voltage Measurement... 14:15:08 Voltage Offset Correction: v_off_ini = 490.291 uV, v_off_fin = 513.363 uV 14:15:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.441 uVs 14:15:08 Integrated Voltage Measurement... 14:15:17 Voltage Offset Correction: v_off_ini = 532.556 uV, v_off_fin = 542.403 uV 14:15:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.024 uVs 14:15:19 I2X Average and RMS of Measurements VT = -117.562 +- 8.515 uVs I2X = 10.816 +- 0.783 uTm^2 14:15:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:15:27 Integrated Voltage Measurement... 14:15:36 Voltage Offset Correction: v_off_ini = 530.394 uV, v_off_fin = 527.175 uV 14:15:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.685 uVs 14:15:36 Integrated Voltage Measurement... 14:15:45 Voltage Offset Correction: v_off_ini = 530.627 uV, v_off_fin = 526.062 uV 14:15:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.483 uVs 14:15:45 Integrated Voltage Measurement... 14:15:54 Voltage Offset Correction: v_off_ini = 514.028 uV, v_off_fin = 514.826 uV 14:15:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.476 uVs 14:15:54 Integrated Voltage Measurement... 14:16:03 Voltage Offset Correction: v_off_ini = 500.821 uV, v_off_fin = 526.989 uV 14:16:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.912 uVs 14:16:03 Integrated Voltage Measurement... 14:16:12 Voltage Offset Correction: v_off_ini = 521.321 uV, v_off_fin = 530.140 uV 14:16:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.507 uVs 14:16:12 Integrated Voltage Measurement... 14:16:21 Voltage Offset Correction: v_off_ini = 529.282 uV, v_off_fin = 514.498 uV 14:16:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.223 uVs 14:16:23 I2Y Average and RMS of Measurements VT = -241.381 +- 8.598 uVs I2Y = -22.207 +- 0.791 uTm^2 14:16:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:37 Integrated Voltage Measurement... 14:16:46 Voltage Offset Correction: v_off_ini = 538.546 uV, v_off_fin = 534.483 uV 14:16:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.348 uVs 14:16:46 Integrated Voltage Measurement... 14:16:55 Voltage Offset Correction: v_off_ini = 492.118 uV, v_off_fin = 502.673 uV 14:16:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 126.391 uVs 14:16:55 Integrated Voltage Measurement... 14:17:04 Voltage Offset Correction: v_off_ini = 504.502 uV, v_off_fin = 516.436 uV 14:17:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.786 uVs 14:17:05 Integrated Voltage Measurement... 14:17:13 Voltage Offset Correction: v_off_ini = 518.778 uV, v_off_fin = 513.398 uV 14:17:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.537 uVs 14:17:14 Integrated Voltage Measurement... 14:17:22 Voltage Offset Correction: v_off_ini = 506.711 uV, v_off_fin = 518.464 uV 14:17:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.117 uVs 14:17:23 Integrated Voltage Measurement... 14:17:32 Voltage Offset Correction: v_off_ini = 504.742 uV, v_off_fin = 518.519 uV 14:17:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.322 uVs 14:17:36 I1X Average and RMS of Measurements VT = -120.750 +- 1.560 uVs I1X = 24.150 +- 0.311 uTm 14:17:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:43 Integrated Voltage Measurement... 14:17:51 Voltage Offset Correction: v_off_ini = 520.900 uV, v_off_fin = 523.745 uV 14:17:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -219.041 uVs 14:17:52 Integrated Voltage Measurement... 14:18:00 Voltage Offset Correction: v_off_ini = 518.275 uV, v_off_fin = 518.679 uV 14:18:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.211 uVs 14:18:01 Integrated Voltage Measurement... 14:18:10 Voltage Offset Correction: v_off_ini = 516.869 uV, v_off_fin = 513.327 uV 14:18:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.347 uVs 14:18:10 Integrated Voltage Measurement... 14:18:19 Voltage Offset Correction: v_off_ini = 524.993 uV, v_off_fin = 554.495 uV 14:18:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.882 uVs 14:18:19 Integrated Voltage Measurement... 14:18:28 Voltage Offset Correction: v_off_ini = 517.491 uV, v_off_fin = 498.162 uV 14:18:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.026 uVs 14:18:28 Integrated Voltage Measurement... 14:18:37 Voltage Offset Correction: v_off_ini = 527.911 uV, v_off_fin = 521.856 uV 14:18:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.181 uVs 14:18:41 I1Y Average and RMS of Measurements VT = -223.448 +- 5.925 uVs I1Y = -44.690 +- 1.185 uTm 14:18:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:48 Integrated Voltage Measurement... 14:18:57 Voltage Offset Correction: v_off_ini = 519.052 uV, v_off_fin = 518.660 uV 14:18:57 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -107.402 uVs 14:18:58 Integrated Voltage Measurement... 14:19:07 Voltage Offset Correction: v_off_ini = 519.110 uV, v_off_fin = 523.338 uV 14:19:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.679 uVs 14:19:07 Integrated Voltage Measurement... 14:19:16 Voltage Offset Correction: v_off_ini = 533.965 uV, v_off_fin = 537.907 uV 14:19:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -130.799 uVs 14:19:16 Integrated Voltage Measurement... 14:19:25 Voltage Offset Correction: v_off_ini = 540.536 uV, v_off_fin = 561.394 uV 14:19:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.378 uVs 14:19:25 Integrated Voltage Measurement... 14:19:34 Voltage Offset Correction: v_off_ini = 555.119 uV, v_off_fin = 540.553 uV 14:19:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.814 uVs 14:19:34 Integrated Voltage Measurement... 14:19:43 Voltage Offset Correction: v_off_ini = 531.370 uV, v_off_fin = 553.774 uV 14:19:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.999 uVs 14:19:45 I2X Average and RMS of Measurements VT = -119.179 +- 4.576 uVs I2X = 10.964 +- 0.421 uTm^2 14:19:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:53 Integrated Voltage Measurement... 14:20:02 Voltage Offset Correction: v_off_ini = 551.253 uV, v_off_fin = 542.669 uV 14:20:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.090 uVs 14:20:02 Integrated Voltage Measurement... 14:20:11 Voltage Offset Correction: v_off_ini = 539.603 uV, v_off_fin = 556.350 uV 14:20:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.691 uVs 14:20:11 Integrated Voltage Measurement... 14:20:20 Voltage Offset Correction: v_off_ini = 555.267 uV, v_off_fin = 554.054 uV 14:20:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.606 uVs 14:20:20 Integrated Voltage Measurement... 14:20:29 Voltage Offset Correction: v_off_ini = 527.506 uV, v_off_fin = 552.472 uV 14:20:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.295 uVs 14:20:29 Integrated Voltage Measurement... 14:20:38 Voltage Offset Correction: v_off_ini = 554.821 uV, v_off_fin = 538.793 uV 14:20:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.999 uVs 14:20:38 Integrated Voltage Measurement... 14:20:47 Voltage Offset Correction: v_off_ini = 534.251 uV, v_off_fin = 533.086 uV 14:20:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.241 uVs 14:20:49 I2Y Average and RMS of Measurements VT = -238.487 +- 3.823 uVs I2Y = -21.941 +- 0.352 uTm^2 14:20:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:21:03 Integrated Voltage Measurement... 14:21:12 Voltage Offset Correction: v_off_ini = 544.954 uV, v_off_fin = 548.362 uV 14:21:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.213 uVs 14:21:12 Integrated Voltage Measurement... 14:21:21 Voltage Offset Correction: v_off_ini = 549.284 uV, v_off_fin = 548.873 uV 14:21:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.271 uVs 14:21:21 Integrated Voltage Measurement... 14:21:30 Voltage Offset Correction: v_off_ini = 547.841 uV, v_off_fin = 547.336 uV 14:21:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.433 uVs 14:21:30 Integrated Voltage Measurement... 14:21:39 Voltage Offset Correction: v_off_ini = 538.134 uV, v_off_fin = 543.137 uV 14:21:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.031 uVs 14:21:39 Integrated Voltage Measurement... 14:21:48 Voltage Offset Correction: v_off_ini = 531.947 uV, v_off_fin = 545.223 uV 14:21:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -123.977 uVs 14:21:48 Integrated Voltage Measurement... 14:21:57 Voltage Offset Correction: v_off_ini = 553.370 uV, v_off_fin = 555.748 uV 14:21:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.570 uVs 14:22:02 I1X Average and RMS of Measurements VT = -124.416 +- 5.100 uVs I1X = 24.883 +- 1.020 uTm 14:22:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:22:08 Integrated Voltage Measurement... 14:22:17 Voltage Offset Correction: v_off_ini = 557.342 uV, v_off_fin = 556.107 uV 14:22:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -233.196 uVs 14:22:17 Integrated Voltage Measurement... 14:22:26 Voltage Offset Correction: v_off_ini = 560.899 uV, v_off_fin = 585.238 uV 14:22:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.268 uVs 14:22:26 Integrated Voltage Measurement... 14:22:35 Voltage Offset Correction: v_off_ini = 544.254 uV, v_off_fin = 528.118 uV 14:22:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.466 uVs 14:22:35 Integrated Voltage Measurement... 14:22:44 Voltage Offset Correction: v_off_ini = 536.758 uV, v_off_fin = 557.387 uV 14:22:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.979 uVs 14:22:44 Integrated Voltage Measurement... 14:22:53 Voltage Offset Correction: v_off_ini = 540.936 uV, v_off_fin = 540.868 uV 14:22:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.448 uVs 14:22:53 Integrated Voltage Measurement... 14:23:02 Voltage Offset Correction: v_off_ini = 537.155 uV, v_off_fin = 549.773 uV 14:23:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.377 uVs 14:23:07 I1Y Average and RMS of Measurements VT = -227.122 +- 0.431 uVs I1Y = -45.425 +- 0.085 uTm 14:23:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:23:14 Integrated Voltage Measurement... 14:23:23 Voltage Offset Correction: v_off_ini = 558.315 uV, v_off_fin = 552.351 uV 14:23:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -124.655 uVs 14:23:23 Integrated Voltage Measurement... 14:23:32 Voltage Offset Correction: v_off_ini = 535.203 uV, v_off_fin = 555.982 uV 14:23:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.473 uVs 14:23:32 Integrated Voltage Measurement... 14:23:41 Voltage Offset Correction: v_off_ini = 565.052 uV, v_off_fin = 559.002 uV 14:23:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.000 uVs 14:23:41 Integrated Voltage Measurement... 14:23:50 Voltage Offset Correction: v_off_ini = 564.523 uV, v_off_fin = 571.299 uV 14:23:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.665 uVs 14:23:50 Integrated Voltage Measurement... 14:23:59 Voltage Offset Correction: v_off_ini = 561.157 uV, v_off_fin = 566.336 uV 14:23:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.742 uVs 14:24:00 Integrated Voltage Measurement... 14:24:08 Voltage Offset Correction: v_off_ini = 570.803 uV, v_off_fin = 576.534 uV 14:24:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.251 uVs 14:24:11 I2X Average and RMS of Measurements VT = -120.464 +- 5.461 uVs I2X = 11.083 +- 0.502 uTm^2 14:24:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:24:19 Integrated Voltage Measurement... 14:24:28 Voltage Offset Correction: v_off_ini = 564.685 uV, v_off_fin = 548.254 uV 14:24:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.531 uVs 14:24:28 Integrated Voltage Measurement... 14:24:37 Voltage Offset Correction: v_off_ini = 562.420 uV, v_off_fin = 571.883 uV 14:24:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.126 uVs 14:24:37 Integrated Voltage Measurement... 14:24:46 Voltage Offset Correction: v_off_ini = 576.137 uV, v_off_fin = 577.999 uV 14:24:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.149 uVs 14:24:46 Integrated Voltage Measurement... 14:24:55 Voltage Offset Correction: v_off_ini = 578.882 uV, v_off_fin = 600.986 uV 14:24:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.612 uVs 14:24:55 Integrated Voltage Measurement... 14:25:04 Voltage Offset Correction: v_off_ini = 598.226 uV, v_off_fin = 579.334 uV 14:25:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.965 uVs 14:25:04 Integrated Voltage Measurement... 14:25:13 Voltage Offset Correction: v_off_ini = 589.183 uV, v_off_fin = 591.622 uV 14:25:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 235.656 uVs 14:25:15 I2Y Average and RMS of Measurements VT = -245.506 +- 7.956 uVs I2Y = -22.587 +- 0.732 uTm^2 14:25:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:25:29 Integrated Voltage Measurement... 14:25:38 Voltage Offset Correction: v_off_ini = 586.732 uV, v_off_fin = 599.180 uV 14:25:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -143.181 uVs 14:25:38 Integrated Voltage Measurement... 14:25:47 Voltage Offset Correction: v_off_ini = 625.196 uV, v_off_fin = 624.779 uV 14:25:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.655 uVs 14:25:47 Integrated Voltage Measurement... 14:25:56 Voltage Offset Correction: v_off_ini = 610.303 uV, v_off_fin = 609.941 uV 14:25:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.793 uVs 14:25:56 Integrated Voltage Measurement... 14:26:05 Voltage Offset Correction: v_off_ini = 594.047 uV, v_off_fin = 598.513 uV 14:26:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.493 uVs 14:26:05 Integrated Voltage Measurement... 14:26:14 Voltage Offset Correction: v_off_ini = 605.379 uV, v_off_fin = 601.847 uV 14:26:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.198 uVs 14:26:14 Integrated Voltage Measurement... 14:26:23 Voltage Offset Correction: v_off_ini = 601.439 uV, v_off_fin = 619.373 uV 14:26:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.997 uVs 14:26:28 I1X Average and RMS of Measurements VT = -130.553 +- 6.737 uVs I1X = 26.111 +- 1.348 uTm 14:26:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:34 Integrated Voltage Measurement... 14:26:43 Voltage Offset Correction: v_off_ini = 612.941 uV, v_off_fin = 605.760 uV 14:26:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.400 uVs 14:26:43 Integrated Voltage Measurement... 14:26:52 Voltage Offset Correction: v_off_ini = 623.183 uV, v_off_fin = 641.182 uV 14:26:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 226.282 uVs 14:26:52 Integrated Voltage Measurement... 14:27:01 Voltage Offset Correction: v_off_ini = 607.686 uV, v_off_fin = 588.141 uV 14:27:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -230.327 uVs 14:27:01 Integrated Voltage Measurement... 14:27:10 Voltage Offset Correction: v_off_ini = 628.044 uV, v_off_fin = 630.802 uV 14:27:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 213.977 uVs 14:27:10 Integrated Voltage Measurement... 14:27:19 Voltage Offset Correction: v_off_ini = 604.644 uV, v_off_fin = 599.758 uV 14:27:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -238.295 uVs 14:27:19 Integrated Voltage Measurement... 14:27:28 Voltage Offset Correction: v_off_ini = 593.420 uV, v_off_fin = 589.540 uV 14:27:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.920 uVs 14:27:33 I1Y Average and RMS of Measurements VT = -225.533 +- 3.083 uVs I1Y = -45.101 +- 0.619 uTm 14:27:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:27:40 Integrated Voltage Measurement... 14:27:49 Voltage Offset Correction: v_off_ini = 620.431 uV, v_off_fin = 606.572 uV 14:27:49 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -124.334 uVs 14:27:49 Integrated Voltage Measurement... 14:27:58 Voltage Offset Correction: v_off_ini = 603.677 uV, v_off_fin = 615.710 uV 14:27:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.410 uVs 14:27:58 Integrated Voltage Measurement... 14:28:07 Voltage Offset Correction: v_off_ini = 616.706 uV, v_off_fin = 609.495 uV 14:28:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.578 uVs 14:28:07 Integrated Voltage Measurement... 14:28:16 Voltage Offset Correction: v_off_ini = 592.830 uV, v_off_fin = 618.260 uV 14:28:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.183 uVs 14:28:16 Integrated Voltage Measurement... 14:28:25 Voltage Offset Correction: v_off_ini = 597.691 uV, v_off_fin = 606.579 uV 14:28:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.019 uVs 14:28:26 Integrated Voltage Measurement... 14:28:35 Voltage Offset Correction: v_off_ini = 603.014 uV, v_off_fin = 605.090 uV 14:28:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.116 uVs 14:28:37 I2X Average and RMS of Measurements VT = -122.107 +- 7.818 uVs I2X = 11.234 +- 0.719 uTm^2 14:28:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:28:45 Integrated Voltage Measurement... 14:28:54 Voltage Offset Correction: v_off_ini = 593.043 uV, v_off_fin = 604.954 uV 14:28:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.099 uVs 14:28:54 Integrated Voltage Measurement... 14:29:03 Voltage Offset Correction: v_off_ini = 625.696 uV, v_off_fin = 614.030 uV 14:29:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.057 uVs 14:29:03 Integrated Voltage Measurement... 14:29:12 Voltage Offset Correction: v_off_ini = 627.032 uV, v_off_fin = 617.691 uV 14:29:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.090 uVs 14:29:12 Integrated Voltage Measurement... 14:29:21 Voltage Offset Correction: v_off_ini = 619.945 uV, v_off_fin = 623.192 uV 14:29:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.872 uVs 14:29:21 Integrated Voltage Measurement... 14:29:30 Voltage Offset Correction: v_off_ini = 601.476 uV, v_off_fin = 624.287 uV 14:29:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0001 mm dXY = 1.0000 mm VT = -241.190 uVs 14:29:30 Integrated Voltage Measurement... 14:29:39 Voltage Offset Correction: v_off_ini = 634.744 uV, v_off_fin = 630.566 uV 14:29:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 243.437 uVs 14:29:41 I2Y Average and RMS of Measurements VT = -243.957 +- 2.861 uVs I2Y = -22.444 +- 0.263 uTm^2 14:29:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:55 Integrated Voltage Measurement... 14:30:04 Voltage Offset Correction: v_off_ini = 623.885 uV, v_off_fin = 626.017 uV 14:30:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -158.611 uVs 14:30:04 Integrated Voltage Measurement... 14:30:13 Voltage Offset Correction: v_off_ini = 620.790 uV, v_off_fin = 618.248 uV 14:30:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.192 uVs 14:30:13 Integrated Voltage Measurement... 14:30:22 Voltage Offset Correction: v_off_ini = 601.817 uV, v_off_fin = 609.002 uV 14:30:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.523 uVs 14:30:22 Integrated Voltage Measurement... 14:30:31 Voltage Offset Correction: v_off_ini = 603.055 uV, v_off_fin = 600.936 uV 14:30:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.586 uVs 14:30:31 Integrated Voltage Measurement... 14:30:40 Voltage Offset Correction: v_off_ini = 600.464 uV, v_off_fin = 604.905 uV 14:30:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.693 uVs 14:30:40 Integrated Voltage Measurement... 14:30:49 Voltage Offset Correction: v_off_ini = 606.181 uV, v_off_fin = 623.027 uV 14:30:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.517 uVs 14:30:54 I1X Average and RMS of Measurements VT = -140.353 +- 9.166 uVs I1X = 28.071 +- 1.834 uTm 14:30:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:31:00 Integrated Voltage Measurement... 14:31:09 Voltage Offset Correction: v_off_ini = 596.322 uV, v_off_fin = 604.987 uV 14:31:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.490 uVs 14:31:09 Integrated Voltage Measurement... 14:31:18 Voltage Offset Correction: v_off_ini = 613.800 uV, v_off_fin = 624.345 uV 14:31:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 223.232 uVs 14:31:19 Integrated Voltage Measurement... 14:31:27 Voltage Offset Correction: v_off_ini = 611.418 uV, v_off_fin = 588.157 uV 14:31:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -238.955 uVs 14:31:28 Integrated Voltage Measurement... 14:31:36 Voltage Offset Correction: v_off_ini = 610.794 uV, v_off_fin = 632.794 uV 14:31:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.464 uVs 14:31:37 Integrated Voltage Measurement... 14:31:45 Voltage Offset Correction: v_off_ini = 614.472 uV, v_off_fin = 613.590 uV 14:31:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -241.239 uVs 14:31:46 Integrated Voltage Measurement... 14:31:54 Voltage Offset Correction: v_off_ini = 620.332 uV, v_off_fin = 628.600 uV 14:31:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.505 uVs 14:31:59 I1Y Average and RMS of Measurements VT = -225.481 +- 4.906 uVs I1Y = -45.091 +- 0.982 uTm 14:32:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:32:06 Integrated Voltage Measurement... 14:32:15 Voltage Offset Correction: v_off_ini = 603.853 uV, v_off_fin = 594.023 uV 14:32:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -114.057 uVs 14:32:15 Integrated Voltage Measurement... 14:32:24 Voltage Offset Correction: v_off_ini = 602.615 uV, v_off_fin = 621.671 uV 14:32:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.442 uVs 14:32:25 Integrated Voltage Measurement... 14:32:34 Voltage Offset Correction: v_off_ini = 621.388 uV, v_off_fin = 607.205 uV 14:32:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.272 uVs 14:32:34 Integrated Voltage Measurement... 14:32:43 Voltage Offset Correction: v_off_ini = 618.505 uV, v_off_fin = 623.450 uV 14:32:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.787 uVs 14:32:43 Integrated Voltage Measurement... 14:32:52 Voltage Offset Correction: v_off_ini = 618.956 uV, v_off_fin = 609.714 uV 14:32:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.751 uVs 14:32:52 Integrated Voltage Measurement... 14:33:01 Voltage Offset Correction: v_off_ini = 619.845 uV, v_off_fin = 635.470 uV 14:33:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 128.578 uVs 14:33:03 I2X Average and RMS of Measurements VT = -121.648 +- 1.855 uVs I2X = 11.192 +- 0.171 uTm^2 14:33:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:33:11 Integrated Voltage Measurement... 14:33:20 Voltage Offset Correction: v_off_ini = 643.073 uV, v_off_fin = 633.518 uV 14:33:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.099 uVs 14:33:20 Integrated Voltage Measurement... 14:33:29 Voltage Offset Correction: v_off_ini = 623.831 uV, v_off_fin = 639.742 uV 14:33:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.691 uVs 14:33:29 Integrated Voltage Measurement... 14:33:38 Voltage Offset Correction: v_off_ini = 635.326 uV, v_off_fin = 637.140 uV 14:33:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.660 uVs 14:33:38 Integrated Voltage Measurement... 14:33:47 Voltage Offset Correction: v_off_ini = 610.793 uV, v_off_fin = 622.061 uV 14:33:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.464 uVs 14:33:47 Integrated Voltage Measurement... 14:33:56 Voltage Offset Correction: v_off_ini = 629.704 uV, v_off_fin = 615.249 uV 14:33:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.527 uVs 14:33:56 Integrated Voltage Measurement... 14:34:05 Voltage Offset Correction: v_off_ini = 632.691 uV, v_off_fin = 632.106 uV 14:34:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.779 uVs 14:34:07 I2Y Average and RMS of Measurements VT = -235.537 +- 9.023 uVs I2Y = -21.669 +- 0.830 uTm^2 14:34:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:34:22 Integrated Voltage Measurement... 14:34:31 Voltage Offset Correction: v_off_ini = 621.489 uV, v_off_fin = 627.427 uV 14:34:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.871 uVs 14:34:31 Integrated Voltage Measurement... 14:34:40 Voltage Offset Correction: v_off_ini = 634.169 uV, v_off_fin = 629.668 uV 14:34:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.242 uVs 14:34:40 Integrated Voltage Measurement... 14:34:49 Voltage Offset Correction: v_off_ini = 645.377 uV, v_off_fin = 615.406 uV 14:34:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.864 uVs 14:34:49 Integrated Voltage Measurement... 14:34:58 Voltage Offset Correction: v_off_ini = 622.430 uV, v_off_fin = 635.924 uV 14:34:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.949 uVs 14:34:58 Integrated Voltage Measurement... 14:35:07 Voltage Offset Correction: v_off_ini = 639.619 uV, v_off_fin = 646.164 uV 14:35:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.227 uVs 14:35:07 Integrated Voltage Measurement... 14:35:16 Voltage Offset Correction: v_off_ini = 634.173 uV, v_off_fin = 643.460 uV 14:35:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.640 uVs 14:35:21 I1X Average and RMS of Measurements VT = -141.965 +- 7.301 uVs I1X = 28.393 +- 1.460 uTm 14:35:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:35:27 Integrated Voltage Measurement... 14:35:36 Voltage Offset Correction: v_off_ini = 662.153 uV, v_off_fin = 650.500 uV 14:35:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.017 uVs 14:35:36 Integrated Voltage Measurement... 14:35:45 Voltage Offset Correction: v_off_ini = 660.820 uV, v_off_fin = 658.143 uV 14:35:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.886 uVs 14:35:45 Integrated Voltage Measurement... 14:35:54 Voltage Offset Correction: v_off_ini = 639.405 uV, v_off_fin = 635.607 uV 14:35:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.611 uVs 14:35:54 Integrated Voltage Measurement... 14:36:03 Voltage Offset Correction: v_off_ini = 631.867 uV, v_off_fin = 624.870 uV 14:36:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.395 uVs 14:36:03 Integrated Voltage Measurement... 14:36:12 Voltage Offset Correction: v_off_ini = 630.842 uV, v_off_fin = 617.838 uV 14:36:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -238.538 uVs 14:36:12 Integrated Voltage Measurement... 14:36:21 Voltage Offset Correction: v_off_ini = 636.235 uV, v_off_fin = 662.030 uV 14:36:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.774 uVs 14:36:25 I1Y Average and RMS of Measurements VT = -227.537 +- 10.269 uVs I1Y = -45.505 +- 2.055 uTm 14:36:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:36:33 Integrated Voltage Measurement... 14:36:42 Voltage Offset Correction: v_off_ini = 676.321 uV, v_off_fin = 642.101 uV 14:36:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.653 uVs 14:36:42 Integrated Voltage Measurement... 14:36:51 Voltage Offset Correction: v_off_ini = 642.432 uV, v_off_fin = 654.070 uV 14:36:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.215 uVs 14:36:51 Integrated Voltage Measurement... 14:37:00 Voltage Offset Correction: v_off_ini = 668.097 uV, v_off_fin = 652.147 uV 14:37:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.779 uVs 14:37:00 Integrated Voltage Measurement... 14:37:09 Voltage Offset Correction: v_off_ini = 660.844 uV, v_off_fin = 663.669 uV 14:37:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 172.498 uVs 14:37:09 Integrated Voltage Measurement... 14:37:18 Voltage Offset Correction: v_off_ini = 656.474 uV, v_off_fin = 651.575 uV 14:37:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.150 uVs 14:37:18 Integrated Voltage Measurement... 14:37:27 Voltage Offset Correction: v_off_ini = 640.038 uV, v_off_fin = 638.241 uV 14:37:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.445 uVs 14:37:30 I2X Average and RMS of Measurements VT = -142.290 +- 3.434 uVs I2X = 13.091 +- 0.316 uTm^2 14:37:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:37:37 Integrated Voltage Measurement... 14:37:46 Voltage Offset Correction: v_off_ini = 613.950 uV, v_off_fin = 595.512 uV 14:37:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.750 uVs 14:37:46 Integrated Voltage Measurement... 14:37:55 Voltage Offset Correction: v_off_ini = 646.567 uV, v_off_fin = 652.845 uV 14:37:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.309 uVs 14:37:55 Integrated Voltage Measurement... 14:38:04 Voltage Offset Correction: v_off_ini = 647.602 uV, v_off_fin = 652.732 uV 14:38:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.770 uVs 14:38:04 Integrated Voltage Measurement... 14:38:13 Voltage Offset Correction: v_off_ini = 643.107 uV, v_off_fin = 655.250 uV 14:38:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.368 uVs 14:38:13 Integrated Voltage Measurement... 14:38:22 Voltage Offset Correction: v_off_ini = 669.657 uV, v_off_fin = 663.629 uV 14:38:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.571 uVs 14:38:22 Integrated Voltage Measurement... 14:38:31 Voltage Offset Correction: v_off_ini = 650.626 uV, v_off_fin = 648.299 uV 14:38:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.740 uVs 14:38:34 I2Y Average and RMS of Measurements VT = -239.418 +- 2.031 uVs I2Y = -22.026 +- 0.187 uTm^2 14:38:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:38:49 Integrated Voltage Measurement... 14:38:58 Voltage Offset Correction: v_off_ini = 652.516 uV, v_off_fin = 652.374 uV 14:38:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.528 uVs 14:38:58 Integrated Voltage Measurement... 14:39:07 Voltage Offset Correction: v_off_ini = 661.818 uV, v_off_fin = 678.233 uV 14:39:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.237 uVs 14:39:07 Integrated Voltage Measurement... 14:39:16 Voltage Offset Correction: v_off_ini = 663.187 uV, v_off_fin = 663.410 uV 14:39:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.185 uVs 14:39:16 Integrated Voltage Measurement... 14:39:25 Voltage Offset Correction: v_off_ini = 669.418 uV, v_off_fin = 650.342 uV 14:39:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.198 uVs 14:39:25 Integrated Voltage Measurement... 14:39:34 Voltage Offset Correction: v_off_ini = 662.566 uV, v_off_fin = 659.893 uV 14:39:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.694 uVs 14:39:34 Integrated Voltage Measurement... 14:39:43 Voltage Offset Correction: v_off_ini = 652.494 uV, v_off_fin = 646.803 uV 14:39:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.907 uVs 14:39:47 I1X Average and RMS of Measurements VT = -138.125 +- 9.273 uVs I1X = 27.625 +- 1.855 uTm 14:39:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:54 Integrated Voltage Measurement... 14:40:03 Voltage Offset Correction: v_off_ini = 674.929 uV, v_off_fin = 667.043 uV 14:40:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.977 uVs 14:40:03 Integrated Voltage Measurement... 14:40:12 Voltage Offset Correction: v_off_ini = 655.160 uV, v_off_fin = 668.731 uV 14:40:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 241.404 uVs 14:40:12 Integrated Voltage Measurement... 14:40:21 Voltage Offset Correction: v_off_ini = 677.256 uV, v_off_fin = 670.558 uV 14:40:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -224.561 uVs 14:40:21 Integrated Voltage Measurement... 14:40:29 Voltage Offset Correction: v_off_ini = 675.299 uV, v_off_fin = 695.393 uV 14:40:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.751 uVs 14:40:30 Integrated Voltage Measurement... 14:40:38 Voltage Offset Correction: v_off_ini = 702.129 uV, v_off_fin = 685.474 uV 14:40:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.030 uVs 14:40:39 Integrated Voltage Measurement... 14:40:47 Voltage Offset Correction: v_off_ini = 679.212 uV, v_off_fin = 700.675 uV 14:40:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 232.965 uVs 14:40:52 I1Y Average and RMS of Measurements VT = -232.115 +- 5.080 uVs I1Y = -46.419 +- 1.017 uTm 14:40:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:59 Integrated Voltage Measurement... 14:41:08 Voltage Offset Correction: v_off_ini = 670.556 uV, v_off_fin = 678.310 uV 14:41:08 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -130.293 uVs 14:41:08 Integrated Voltage Measurement... 14:41:17 Voltage Offset Correction: v_off_ini = 689.787 uV, v_off_fin = 693.265 uV 14:41:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.837 uVs 14:41:17 Integrated Voltage Measurement... 14:41:26 Voltage Offset Correction: v_off_ini = 689.749 uV, v_off_fin = 688.898 uV 14:41:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.506 uVs 14:41:26 Integrated Voltage Measurement... 14:41:35 Voltage Offset Correction: v_off_ini = 691.222 uV, v_off_fin = 704.625 uV 14:41:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.636 uVs 14:41:35 Integrated Voltage Measurement... 14:41:44 Voltage Offset Correction: v_off_ini = 704.171 uV, v_off_fin = 718.054 uV 14:41:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.594 uVs 14:41:44 Integrated Voltage Measurement... 14:41:53 Voltage Offset Correction: v_off_ini = 696.304 uV, v_off_fin = 725.345 uV 14:41:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 183.477 uVs 14:41:56 I2X Average and RMS of Measurements VT = -147.890 +- 8.394 uVs I2X = 13.606 +- 0.772 uTm^2 14:42:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:03 Integrated Voltage Measurement... 14:42:12 Voltage Offset Correction: v_off_ini = 726.964 uV, v_off_fin = 711.250 uV 14:42:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.632 uVs 14:42:12 Integrated Voltage Measurement... 14:42:21 Voltage Offset Correction: v_off_ini = 715.455 uV, v_off_fin = 731.283 uV 14:42:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.001 uVs 14:42:21 Integrated Voltage Measurement... 14:42:30 Voltage Offset Correction: v_off_ini = 717.804 uV, v_off_fin = 717.206 uV 14:42:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.163 uVs 14:42:30 Integrated Voltage Measurement... 14:42:39 Voltage Offset Correction: v_off_ini = 722.003 uV, v_off_fin = 723.928 uV 14:42:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.599 uVs 14:42:40 Integrated Voltage Measurement... 14:42:48 Voltage Offset Correction: v_off_ini = 719.916 uV, v_off_fin = 719.692 uV 14:42:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.271 uVs 14:42:49 Integrated Voltage Measurement... 14:42:58 Voltage Offset Correction: v_off_ini = 715.503 uV, v_off_fin = 730.947 uV 14:42:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.541 uVs 14:43:00 I2Y Average and RMS of Measurements VT = -237.701 +- 12.930 uVs I2Y = -21.869 +- 1.190 uTm^2 14:43:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:17 Integrated Voltage Measurement... 14:43:26 Voltage Offset Correction: v_off_ini = 716.800 uV, v_off_fin = 720.737 uV 14:43:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -146.945 uVs 14:43:26 Integrated Voltage Measurement... 14:43:35 Voltage Offset Correction: v_off_ini = 734.877 uV, v_off_fin = 726.936 uV 14:43:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.711 uVs 14:43:35 Integrated Voltage Measurement... 14:43:44 Voltage Offset Correction: v_off_ini = 709.713 uV, v_off_fin = 720.609 uV 14:43:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.059 uVs 14:43:44 Integrated Voltage Measurement... 14:43:53 Voltage Offset Correction: v_off_ini = 727.030 uV, v_off_fin = 726.533 uV 14:43:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.381 uVs 14:43:53 Integrated Voltage Measurement... 14:44:02 Voltage Offset Correction: v_off_ini = 750.165 uV, v_off_fin = 748.887 uV 14:44:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.162 uVs 14:44:02 Integrated Voltage Measurement... 14:44:11 Voltage Offset Correction: v_off_ini = 745.278 uV, v_off_fin = 739.158 uV 14:44:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.517 uVs 14:44:15 I1X Average and RMS of Measurements VT = -138.129 +- 2.331 uVs I1X = 27.626 +- 0.467 uTm 14:44:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:44:22 Integrated Voltage Measurement... 14:44:31 Voltage Offset Correction: v_off_ini = 737.621 uV, v_off_fin = 724.718 uV 14:44:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.615 uVs 14:44:31 Integrated Voltage Measurement... 14:44:40 Voltage Offset Correction: v_off_ini = 725.441 uV, v_off_fin = 734.601 uV 14:44:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 233.878 uVs 14:44:40 Integrated Voltage Measurement... 14:44:49 Voltage Offset Correction: v_off_ini = 742.164 uV, v_off_fin = 733.926 uV 14:44:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -229.638 uVs 14:44:49 Integrated Voltage Measurement... 14:44:58 Voltage Offset Correction: v_off_ini = 742.731 uV, v_off_fin = 749.587 uV 14:44:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 178.681 uVs 14:44:58 Integrated Voltage Measurement... 14:45:07 Voltage Offset Correction: v_off_ini = 758.631 uV, v_off_fin = 735.881 uV 14:45:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -212.253 uVs 14:45:07 Integrated Voltage Measurement... 14:45:16 Voltage Offset Correction: v_off_ini = 744.412 uV, v_off_fin = 769.409 uV 14:45:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.009 uVs 14:45:20 I1Y Average and RMS of Measurements VT = -219.179 +- 10.910 uVs I1Y = -43.830 +- 2.184 uTm 14:45:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:45:28 Integrated Voltage Measurement... 14:45:37 Voltage Offset Correction: v_off_ini = 754.206 uV, v_off_fin = 732.186 uV 14:45:37 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -110.012 uVs 14:45:37 Integrated Voltage Measurement... 14:45:46 Voltage Offset Correction: v_off_ini = 753.191 uV, v_off_fin = 742.979 uV 14:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.831 uVs 14:45:46 Integrated Voltage Measurement... 14:45:55 Voltage Offset Correction: v_off_ini = 754.093 uV, v_off_fin = 755.549 uV 14:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.465 uVs 14:45:55 Integrated Voltage Measurement... 14:46:04 Voltage Offset Correction: v_off_ini = 765.717 uV, v_off_fin = 788.112 uV 14:46:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 211.244 uVs 14:46:04 Integrated Voltage Measurement... 14:46:13 Voltage Offset Correction: v_off_ini = 760.505 uV, v_off_fin = 757.392 uV 14:46:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.362 uVs 14:46:13 Integrated Voltage Measurement... 14:46:22 Voltage Offset Correction: v_off_ini = 772.828 uV, v_off_fin = 760.156 uV 14:46:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.900 uVs 14:46:24 I2X Average and RMS of Measurements VT = -150.302 +- 23.329 uVs I2X = 13.827 +- 2.147 uTm^2 14:46:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:32 Integrated Voltage Measurement... 14:46:41 Voltage Offset Correction: v_off_ini = 774.093 uV, v_off_fin = 782.435 uV 14:46:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.654 uVs 14:46:41 Integrated Voltage Measurement... 14:46:50 Voltage Offset Correction: v_off_ini = 775.552 uV, v_off_fin = 770.311 uV 14:46:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.597 uVs 14:46:50 Integrated Voltage Measurement... 14:46:59 Voltage Offset Correction: v_off_ini = 752.966 uV, v_off_fin = 753.038 uV 14:46:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.912 uVs 14:46:59 Integrated Voltage Measurement... 14:47:08 Voltage Offset Correction: v_off_ini = 750.307 uV, v_off_fin = 763.394 uV 14:47:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.138 uVs 14:47:08 Integrated Voltage Measurement... 14:47:17 Voltage Offset Correction: v_off_ini = 759.218 uV, v_off_fin = 763.256 uV 14:47:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.864 uVs 14:47:17 Integrated Voltage Measurement... 14:47:26 Voltage Offset Correction: v_off_ini = 764.151 uV, v_off_fin = 763.280 uV 14:47:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.641 uVs 14:47:28 I2Y Average and RMS of Measurements VT = -244.634 +- 4.508 uVs I2Y = -22.506 +- 0.415 uTm^2 14:47:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:46 Integrated Voltage Measurement... 14:47:55 Voltage Offset Correction: v_off_ini = 791.538 uV, v_off_fin = 783.766 uV 14:47:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -131.470 uVs 14:47:55 Integrated Voltage Measurement... 14:48:04 Voltage Offset Correction: v_off_ini = 766.842 uV, v_off_fin = 759.451 uV 14:48:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.257 uVs 14:48:04 Integrated Voltage Measurement... 14:48:13 Voltage Offset Correction: v_off_ini = 753.317 uV, v_off_fin = 757.926 uV 14:48:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.916 uVs 14:48:13 Integrated Voltage Measurement... 14:48:22 Voltage Offset Correction: v_off_ini = 765.237 uV, v_off_fin = 764.907 uV 14:48:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.316 uVs 14:48:22 Integrated Voltage Measurement... 14:48:31 Voltage Offset Correction: v_off_ini = 754.473 uV, v_off_fin = 766.793 uV 14:48:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.460 uVs 14:48:31 Integrated Voltage Measurement... 14:48:40 Voltage Offset Correction: v_off_ini = 770.217 uV, v_off_fin = 769.716 uV 14:48:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.086 uVs 14:48:44 I1X Average and RMS of Measurements VT = -142.584 +- 6.435 uVs I1X = 28.517 +- 1.286 uTm 14:48:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:51 Integrated Voltage Measurement... 14:49:00 Voltage Offset Correction: v_off_ini = 751.521 uV, v_off_fin = 761.493 uV 14:49:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.589 uVs 14:49:00 Integrated Voltage Measurement... 14:49:09 Voltage Offset Correction: v_off_ini = 783.662 uV, v_off_fin = 796.129 uV 14:49:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.805 uVs 14:49:09 Integrated Voltage Measurement... 14:49:18 Voltage Offset Correction: v_off_ini = 785.678 uV, v_off_fin = 771.230 uV 14:49:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.030 uVs 14:49:18 Integrated Voltage Measurement... 14:49:27 Voltage Offset Correction: v_off_ini = 792.938 uV, v_off_fin = 800.361 uV 14:49:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.720 uVs 14:49:27 Integrated Voltage Measurement... 14:49:36 Voltage Offset Correction: v_off_ini = 782.015 uV, v_off_fin = 782.014 uV 14:49:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.854 uVs 14:49:36 Integrated Voltage Measurement... 14:49:45 Voltage Offset Correction: v_off_ini = 791.933 uV, v_off_fin = 801.373 uV 14:49:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.751 uVs 14:49:49 I1Y Average and RMS of Measurements VT = -229.458 +- 7.398 uVs I1Y = -45.888 +- 1.479 uTm 14:49:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:56 Integrated Voltage Measurement... 14:50:05 Voltage Offset Correction: v_off_ini = 795.519 uV, v_off_fin = 784.046 uV 14:50:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -122.910 uVs 14:50:06 Integrated Voltage Measurement... 14:50:15 Voltage Offset Correction: v_off_ini = 786.861 uV, v_off_fin = 802.929 uV 14:50:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.065 uVs 14:50:15 Integrated Voltage Measurement... 14:50:24 Voltage Offset Correction: v_off_ini = 784.002 uV, v_off_fin = 782.340 uV 14:50:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.519 uVs 14:50:24 Integrated Voltage Measurement... 14:50:33 Voltage Offset Correction: v_off_ini = 774.272 uV, v_off_fin = 790.687 uV 14:50:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.304 uVs 14:50:33 Integrated Voltage Measurement... 14:50:42 Voltage Offset Correction: v_off_ini = 778.496 uV, v_off_fin = 774.318 uV 14:50:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -133.532 uVs 14:50:42 Integrated Voltage Measurement... 14:50:51 Voltage Offset Correction: v_off_ini = 778.697 uV, v_off_fin = 791.758 uV 14:50:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.578 uVs 14:50:53 I2X Average and RMS of Measurements VT = -132.985 +- 8.950 uVs I2X = 12.235 +- 0.823 uTm^2 14:50:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:01 Integrated Voltage Measurement... 14:51:10 Voltage Offset Correction: v_off_ini = 789.450 uV, v_off_fin = 788.349 uV 14:51:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.946 uVs 14:51:10 Integrated Voltage Measurement... 14:51:19 Voltage Offset Correction: v_off_ini = 790.078 uV, v_off_fin = 781.777 uV 14:51:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.008 uVs 14:51:19 Integrated Voltage Measurement... 14:51:28 Voltage Offset Correction: v_off_ini = 788.871 uV, v_off_fin = 788.046 uV 14:51:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.029 uVs 14:51:28 Integrated Voltage Measurement... 14:51:37 Voltage Offset Correction: v_off_ini = 785.525 uV, v_off_fin = 790.669 uV 14:51:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.432 uVs 14:51:37 Integrated Voltage Measurement... 14:51:46 Voltage Offset Correction: v_off_ini = 800.553 uV, v_off_fin = 779.689 uV 14:51:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -236.589 uVs 14:51:46 Integrated Voltage Measurement... 14:51:55 Voltage Offset Correction: v_off_ini = 772.534 uV, v_off_fin = 787.913 uV 14:51:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.771 uVs 14:51:57 I2Y Average and RMS of Measurements VT = -243.296 +- 8.613 uVs I2Y = -22.384 +- 0.792 uTm^2 14:52:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:15 Integrated Voltage Measurement... 14:52:24 Voltage Offset Correction: v_off_ini = 799.434 uV, v_off_fin = 794.260 uV 14:52:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.729 uVs 14:52:24 Integrated Voltage Measurement... 14:52:33 Voltage Offset Correction: v_off_ini = 777.034 uV, v_off_fin = 782.002 uV 14:52:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.454 uVs 14:52:33 Integrated Voltage Measurement... 14:52:42 Voltage Offset Correction: v_off_ini = 807.051 uV, v_off_fin = 805.009 uV 14:52:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.037 uVs 14:52:42 Integrated Voltage Measurement... 14:52:51 Voltage Offset Correction: v_off_ini = 830.494 uV, v_off_fin = 823.448 uV 14:52:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.048 uVs 14:52:51 Integrated Voltage Measurement... 14:53:00 Voltage Offset Correction: v_off_ini = 816.846 uV, v_off_fin = 815.068 uV 14:53:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.338 uVs 14:53:00 Integrated Voltage Measurement... 14:53:09 Voltage Offset Correction: v_off_ini = 812.890 uV, v_off_fin = 801.999 uV 14:53:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.769 uVs 14:53:13 I1X Average and RMS of Measurements VT = -139.396 +- 5.248 uVs I1X = 27.879 +- 1.050 uTm 14:53:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:20 Integrated Voltage Measurement... 14:53:29 Voltage Offset Correction: v_off_ini = 814.991 uV, v_off_fin = 805.947 uV 14:53:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.519 uVs 14:53:29 Integrated Voltage Measurement... 14:53:38 Voltage Offset Correction: v_off_ini = 821.614 uV, v_off_fin = 843.233 uV 14:53:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.778 uVs 14:53:38 Integrated Voltage Measurement... 14:53:47 Voltage Offset Correction: v_off_ini = 818.036 uV, v_off_fin = 782.425 uV 14:53:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.723 uVs 14:53:47 Integrated Voltage Measurement... 14:53:56 Voltage Offset Correction: v_off_ini = 815.106 uV, v_off_fin = 840.199 uV 14:53:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.879 uVs 14:53:56 Integrated Voltage Measurement... 14:54:05 Voltage Offset Correction: v_off_ini = 822.203 uV, v_off_fin = 818.936 uV 14:54:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.054 uVs 14:54:05 Integrated Voltage Measurement... 14:54:14 Voltage Offset Correction: v_off_ini = 850.534 uV, v_off_fin = 848.105 uV 14:54:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 234.039 uVs 14:54:18 I1Y Average and RMS of Measurements VT = -228.999 +- 1.597 uVs I1Y = -45.795 +- 0.318 uTm 14:54:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:26 Integrated Voltage Measurement... 14:54:35 Voltage Offset Correction: v_off_ini = 835.332 uV, v_off_fin = 833.854 uV 14:54:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -123.351 uVs 14:54:35 Integrated Voltage Measurement... 14:54:44 Voltage Offset Correction: v_off_ini = 834.489 uV, v_off_fin = 847.532 uV 14:54:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.287 uVs 14:54:44 Integrated Voltage Measurement... 14:54:53 Voltage Offset Correction: v_off_ini = 859.232 uV, v_off_fin = 837.180 uV 14:54:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.963 uVs 14:54:53 Integrated Voltage Measurement... 14:55:02 Voltage Offset Correction: v_off_ini = 862.060 uV, v_off_fin = 840.868 uV 14:55:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.221 uVs 14:55:02 Integrated Voltage Measurement... 14:55:11 Voltage Offset Correction: v_off_ini = 860.986 uV, v_off_fin = 846.111 uV 14:55:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.530 uVs 14:55:11 Integrated Voltage Measurement... 14:55:20 Voltage Offset Correction: v_off_ini = 813.390 uV, v_off_fin = 844.083 uV 14:55:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.046 uVs 14:55:22 I2X Average and RMS of Measurements VT = -132.400 +- 8.053 uVs I2X = 12.181 +- 0.741 uTm^2 14:55:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:30 Integrated Voltage Measurement... 14:55:39 Voltage Offset Correction: v_off_ini = 834.477 uV, v_off_fin = 846.863 uV 14:55:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.540 uVs 14:55:39 Integrated Voltage Measurement... 14:55:48 Voltage Offset Correction: v_off_ini = 853.474 uV, v_off_fin = 853.674 uV 14:55:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.204 uVs 14:55:48 Integrated Voltage Measurement... 14:55:57 Voltage Offset Correction: v_off_ini = 862.869 uV, v_off_fin = 871.947 uV 14:55:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.045 uVs 14:55:57 Integrated Voltage Measurement... 14:56:06 Voltage Offset Correction: v_off_ini = 862.453 uV, v_off_fin = 869.876 uV 14:56:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.144 uVs 14:56:06 Integrated Voltage Measurement... 14:56:15 Voltage Offset Correction: v_off_ini = 868.128 uV, v_off_fin = 874.847 uV 14:56:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.953 uVs 14:56:15 Integrated Voltage Measurement... 14:56:24 Voltage Offset Correction: v_off_ini = 861.834 uV, v_off_fin = 865.043 uV 14:56:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.917 uVs 14:56:27 I2Y Average and RMS of Measurements VT = -249.300 +- 2.325 uVs I2Y = -22.936 +- 0.214 uTm^2 14:56:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:44 Integrated Voltage Measurement... 14:56:53 Voltage Offset Correction: v_off_ini = 882.411 uV, v_off_fin = 875.052 uV 14:56:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.000 uVs 14:56:53 Integrated Voltage Measurement... 14:57:02 Voltage Offset Correction: v_off_ini = 884.265 uV, v_off_fin = 889.623 uV 14:57:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.226 uVs 14:57:02 Integrated Voltage Measurement... 14:57:11 Voltage Offset Correction: v_off_ini = 874.471 uV, v_off_fin = 846.815 uV 14:57:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.228 uVs 14:57:11 Integrated Voltage Measurement... 14:57:20 Voltage Offset Correction: v_off_ini = 850.655 uV, v_off_fin = 845.441 uV 14:57:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.785 uVs 14:57:20 Integrated Voltage Measurement... 14:57:29 Voltage Offset Correction: v_off_ini = 864.968 uV, v_off_fin = 871.834 uV 14:57:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.789 uVs 14:57:29 Integrated Voltage Measurement... 14:57:38 Voltage Offset Correction: v_off_ini = 843.211 uV, v_off_fin = 842.932 uV 14:57:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.466 uVs 14:57:42 I1X Average and RMS of Measurements VT = -128.249 +- 5.376 uVs I1X = 25.650 +- 1.075 uTm 14:57:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:49 Integrated Voltage Measurement... 14:57:58 Voltage Offset Correction: v_off_ini = 834.606 uV, v_off_fin = 824.785 uV 14:57:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.100 uVs 14:57:58 Integrated Voltage Measurement... 14:58:07 Voltage Offset Correction: v_off_ini = 869.198 uV, v_off_fin = 863.130 uV 14:58:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 242.764 uVs 14:58:07 Integrated Voltage Measurement... 14:58:16 Voltage Offset Correction: v_off_ini = 852.617 uV, v_off_fin = 842.167 uV 14:58:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -216.476 uVs 14:58:16 Integrated Voltage Measurement... 14:58:25 Voltage Offset Correction: v_off_ini = 861.293 uV, v_off_fin = 866.265 uV 14:58:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 246.440 uVs 14:58:25 Integrated Voltage Measurement... 14:58:34 Voltage Offset Correction: v_off_ini = 859.976 uV, v_off_fin = 847.890 uV 14:58:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.475 uVs 14:58:34 Integrated Voltage Measurement... 14:58:43 Voltage Offset Correction: v_off_ini = 853.848 uV, v_off_fin = 868.996 uV 14:58:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 248.842 uVs 14:58:47 I1Y Average and RMS of Measurements VT = -232.016 +- 4.397 uVs I1Y = -46.397 +- 0.878 uTm 14:58:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:55 Integrated Voltage Measurement... 14:59:04 Voltage Offset Correction: v_off_ini = 868.886 uV, v_off_fin = 864.326 uV 14:59:04 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -118.578 uVs 14:59:04 Integrated Voltage Measurement... 14:59:13 Voltage Offset Correction: v_off_ini = 869.828 uV, v_off_fin = 859.907 uV 14:59:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 138.788 uVs 14:59:13 Integrated Voltage Measurement... 14:59:22 Voltage Offset Correction: v_off_ini = 859.753 uV, v_off_fin = 867.372 uV 14:59:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.573 uVs 14:59:22 Integrated Voltage Measurement... 14:59:31 Voltage Offset Correction: v_off_ini = 866.608 uV, v_off_fin = 883.669 uV 14:59:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.067 uVs 14:59:31 Integrated Voltage Measurement... 14:59:40 Voltage Offset Correction: v_off_ini = 852.280 uV, v_off_fin = 871.053 uV 14:59:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.908 uVs 14:59:40 Integrated Voltage Measurement... 14:59:49 Voltage Offset Correction: v_off_ini = 895.312 uV, v_off_fin = 894.487 uV 14:59:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.934 uVs 14:59:52 I2X Average and RMS of Measurements VT = -128.808 +- 4.941 uVs I2X = 11.850 +- 0.455 uTm^2 14:59:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:59 Integrated Voltage Measurement... 15:00:08 Voltage Offset Correction: v_off_ini = 888.068 uV, v_off_fin = 878.594 uV 15:00:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.572 uVs 15:00:08 Integrated Voltage Measurement... 15:00:17 Voltage Offset Correction: v_off_ini = 891.517 uV, v_off_fin = 899.869 uV 15:00:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.305 uVs 15:00:18 Integrated Voltage Measurement... 15:00:26 Voltage Offset Correction: v_off_ini = 888.162 uV, v_off_fin = 895.941 uV 15:00:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.528 uVs 15:00:27 Integrated Voltage Measurement... 15:00:36 Voltage Offset Correction: v_off_ini = 893.476 uV, v_off_fin = 889.038 uV 15:00:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.574 uVs 15:00:36 Integrated Voltage Measurement... 15:00:45 Voltage Offset Correction: v_off_ini = 892.626 uV, v_off_fin = 896.546 uV 15:00:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.952 uVs 15:00:45 Integrated Voltage Measurement... 15:00:54 Voltage Offset Correction: v_off_ini = 884.524 uV, v_off_fin = 882.079 uV 15:00:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.109 uVs 15:00:56 I2Y Average and RMS of Measurements VT = -250.507 +- 5.885 uVs I2Y = -23.047 +- 0.541 uTm^2 15:01:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:13 Integrated Voltage Measurement... 15:01:22 Voltage Offset Correction: v_off_ini = 895.422 uV, v_off_fin = 877.068 uV 15:01:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -147.401 uVs 15:01:22 Integrated Voltage Measurement... 15:01:31 Voltage Offset Correction: v_off_ini = 907.663 uV, v_off_fin = 896.929 uV 15:01:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.864 uVs 15:01:31 Integrated Voltage Measurement... 15:01:40 Voltage Offset Correction: v_off_ini = 907.898 uV, v_off_fin = 900.725 uV 15:01:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.531 uVs 15:01:40 Integrated Voltage Measurement... 15:01:49 Voltage Offset Correction: v_off_ini = 897.745 uV, v_off_fin = 903.142 uV 15:01:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.340 uVs 15:01:49 Integrated Voltage Measurement... 15:01:58 Voltage Offset Correction: v_off_ini = 883.332 uV, v_off_fin = 887.822 uV 15:01:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.601 uVs 15:01:58 Integrated Voltage Measurement... 15:02:07 Voltage Offset Correction: v_off_ini = 895.689 uV, v_off_fin = 906.688 uV 15:02:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.019 uVs 15:02:12 I1X Average and RMS of Measurements VT = -130.293 +- 11.379 uVs I1X = 26.059 +- 2.276 uTm 15:02:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:18 Integrated Voltage Measurement... 15:02:27 Voltage Offset Correction: v_off_ini = 911.833 uV, v_off_fin = 894.317 uV 15:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -229.734 uVs 15:02:28 Integrated Voltage Measurement... 15:02:36 Voltage Offset Correction: v_off_ini = 914.213 uV, v_off_fin = 935.703 uV 15:02:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.858 uVs 15:02:37 Integrated Voltage Measurement... 15:02:45 Voltage Offset Correction: v_off_ini = 919.353 uV, v_off_fin = 901.623 uV 15:02:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -247.711 uVs 15:02:46 Integrated Voltage Measurement... 15:02:54 Voltage Offset Correction: v_off_ini = 894.848 uV, v_off_fin = 922.601 uV 15:02:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.757 uVs 15:02:55 Integrated Voltage Measurement... 15:03:04 Voltage Offset Correction: v_off_ini = 907.103 uV, v_off_fin = 889.616 uV 15:03:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -230.448 uVs 15:03:04 Integrated Voltage Measurement... 15:03:13 Voltage Offset Correction: v_off_ini = 908.759 uV, v_off_fin = 927.351 uV 15:03:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 238.647 uVs 15:03:17 I1Y Average and RMS of Measurements VT = -240.026 +- 5.322 uVs I1Y = -48.002 +- 1.064 uTm 15:03:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:24 Integrated Voltage Measurement... 15:03:33 Voltage Offset Correction: v_off_ini = 904.848 uV, v_off_fin = 894.762 uV 15:03:33 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -124.337 uVs 15:03:34 Integrated Voltage Measurement... 15:03:43 Voltage Offset Correction: v_off_ini = 913.342 uV, v_off_fin = 908.411 uV 15:03:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.673 uVs 15:03:43 Integrated Voltage Measurement... 15:03:52 Voltage Offset Correction: v_off_ini = 908.924 uV, v_off_fin = 905.994 uV 15:03:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.757 uVs 15:03:52 Integrated Voltage Measurement... 15:04:01 Voltage Offset Correction: v_off_ini = 929.439 uV, v_off_fin = 921.320 uV 15:04:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.358 uVs 15:04:01 Integrated Voltage Measurement... 15:04:10 Voltage Offset Correction: v_off_ini = 919.147 uV, v_off_fin = 907.073 uV 15:04:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.074 uVs 15:04:10 Integrated Voltage Measurement... 15:04:19 Voltage Offset Correction: v_off_ini = 916.000 uV, v_off_fin = 915.776 uV 15:04:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.243 uVs 15:04:21 I2X Average and RMS of Measurements VT = -118.740 +- 4.429 uVs I2X = 10.924 +- 0.408 uTm^2 15:04:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:29 Integrated Voltage Measurement... 15:04:38 Voltage Offset Correction: v_off_ini = 916.747 uV, v_off_fin = 939.986 uV 15:04:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.507 uVs 15:04:38 Integrated Voltage Measurement... 15:04:47 Voltage Offset Correction: v_off_ini = 902.179 uV, v_off_fin = 915.838 uV 15:04:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.419 uVs 15:04:47 Integrated Voltage Measurement... 15:04:56 Voltage Offset Correction: v_off_ini = 931.533 uV, v_off_fin = 923.749 uV 15:04:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.923 uVs 15:04:56 Integrated Voltage Measurement... 15:05:05 Voltage Offset Correction: v_off_ini = 918.887 uV, v_off_fin = 907.311 uV 15:05:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.026 uVs 15:05:05 Integrated Voltage Measurement... 15:05:14 Voltage Offset Correction: v_off_ini = 924.948 uV, v_off_fin = 929.721 uV 15:05:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.128 uVs 15:05:14 Integrated Voltage Measurement... 15:05:23 Voltage Offset Correction: v_off_ini = 933.715 uV, v_off_fin = 937.324 uV 15:05:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.756 uVs 15:05:26 I2Y Average and RMS of Measurements VT = -253.127 +- 2.262 uVs I2Y = -23.288 +- 0.208 uTm^2 15:05:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:43 Integrated Voltage Measurement... 15:05:52 Voltage Offset Correction: v_off_ini = 936.272 uV, v_off_fin = 926.546 uV 15:05:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.168 uVs 15:05:52 Integrated Voltage Measurement... 15:06:01 Voltage Offset Correction: v_off_ini = 935.953 uV, v_off_fin = 943.705 uV 15:06:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.927 uVs 15:06:01 Integrated Voltage Measurement... 15:06:10 Voltage Offset Correction: v_off_ini = 939.361 uV, v_off_fin = 936.990 uV 15:06:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.561 uVs 15:06:10 Integrated Voltage Measurement... 15:06:19 Voltage Offset Correction: v_off_ini = 943.724 uV, v_off_fin = 942.736 uV 15:06:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.035 uVs 15:06:19 Integrated Voltage Measurement... 15:06:28 Voltage Offset Correction: v_off_ini = 941.023 uV, v_off_fin = 941.097 uV 15:06:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.661 uVs 15:06:28 Integrated Voltage Measurement... 15:06:37 Voltage Offset Correction: v_off_ini = 949.455 uV, v_off_fin = 944.457 uV 15:06:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.130 uVs 15:06:41 I1X Average and RMS of Measurements VT = -123.580 +- 4.943 uVs I1X = 24.716 +- 0.989 uTm 15:06:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:48 Integrated Voltage Measurement... 15:06:57 Voltage Offset Correction: v_off_ini = 952.366 uV, v_off_fin = 936.485 uV 15:06:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.294 uVs 15:06:57 Integrated Voltage Measurement... 15:07:06 Voltage Offset Correction: v_off_ini = 926.230 uV, v_off_fin = 932.674 uV 15:07:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 236.653 uVs 15:07:06 Integrated Voltage Measurement... 15:07:15 Voltage Offset Correction: v_off_ini = 934.417 uV, v_off_fin = 921.117 uV 15:07:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -246.092 uVs 15:07:15 Integrated Voltage Measurement... 15:07:24 Voltage Offset Correction: v_off_ini = 935.917 uV, v_off_fin = 939.371 uV 15:07:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.501 uVs 15:07:24 Integrated Voltage Measurement... 15:07:33 Voltage Offset Correction: v_off_ini = 950.130 uV, v_off_fin = 945.273 uV 15:07:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -249.029 uVs 15:07:33 Integrated Voltage Measurement... 15:07:42 Voltage Offset Correction: v_off_ini = 954.100 uV, v_off_fin = 967.182 uV 15:07:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 238.802 uVs 15:07:46 I1Y Average and RMS of Measurements VT = -241.228 +- 1.960 uVs I1Y = -48.241 +- 0.390 uTm 15:07:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:54 Integrated Voltage Measurement... 15:08:03 Voltage Offset Correction: v_off_ini = 939.031 uV, v_off_fin = 946.236 uV 15:08:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -129.706 uVs 15:08:03 Integrated Voltage Measurement... 15:08:12 Voltage Offset Correction: v_off_ini = 949.204 uV, v_off_fin = 942.477 uV 15:08:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.862 uVs 15:08:12 Integrated Voltage Measurement... 15:08:21 Voltage Offset Correction: v_off_ini = 934.844 uV, v_off_fin = 926.808 uV 15:08:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.005 uVs 15:08:21 Integrated Voltage Measurement... 15:08:30 Voltage Offset Correction: v_off_ini = 961.015 uV, v_off_fin = 949.989 uV 15:08:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.875 uVs 15:08:30 Integrated Voltage Measurement... 15:08:39 Voltage Offset Correction: v_off_ini = 938.076 uV, v_off_fin = 936.377 uV 15:08:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.709 uVs 15:08:39 Integrated Voltage Measurement... 15:08:48 Voltage Offset Correction: v_off_ini = 951.304 uV, v_off_fin = 946.763 uV 15:08:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.486 uVs 15:08:51 I2X Average and RMS of Measurements VT = -120.440 +- 5.595 uVs I2X = 11.080 +- 0.515 uTm^2 15:08:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:58 Integrated Voltage Measurement... 15:09:07 Voltage Offset Correction: v_off_ini = 962.813 uV, v_off_fin = 933.788 uV 15:09:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.885 uVs 15:09:08 Integrated Voltage Measurement... 15:09:17 Voltage Offset Correction: v_off_ini = 950.722 uV, v_off_fin = 968.963 uV 15:09:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.704 uVs 15:09:17 Integrated Voltage Measurement... 15:09:26 Voltage Offset Correction: v_off_ini = 970.156 uV, v_off_fin = 965.763 uV 15:09:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.855 uVs 15:09:26 Integrated Voltage Measurement... 15:09:35 Voltage Offset Correction: v_off_ini = 934.431 uV, v_off_fin = 939.714 uV 15:09:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.608 uVs 15:09:35 Integrated Voltage Measurement... 15:09:44 Voltage Offset Correction: v_off_ini = 948.874 uV, v_off_fin = 922.901 uV 15:09:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.899 uVs 15:09:44 Integrated Voltage Measurement... 15:09:53 Voltage Offset Correction: v_off_ini = 920.281 uV, v_off_fin = 922.156 uV 15:09:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.867 uVs 15:09:55 I2Y Average and RMS of Measurements VT = -251.303 +- 9.446 uVs I2Y = -23.120 +- 0.869 uTm^2 15:09:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm