SLAC Magnetic Measurements Date: 02-13-2025 Time: 10:38:50 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10090 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 2 Measurement Device: Operator: YL Comment: 10:38:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:38:59 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:39:01 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:39:03 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:39:04 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:39:43 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:39:47 Integrated Voltage Measurement... 10:39:56 Voltage Offset Correction: v_off_ini = 810.963 uV, v_off_fin = 812.417 uV 10:39:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.192 uVs 10:39:56 Integrated Voltage Measurement... 10:40:05 Voltage Offset Correction: v_off_ini = 818.082 uV, v_off_fin = 810.064 uV 10:40:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.945 uVs 10:40:05 Integrated Voltage Measurement... 10:40:14 Voltage Offset Correction: v_off_ini = 804.624 uV, v_off_fin = 818.412 uV 10:40:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.372 uVs 10:40:14 Integrated Voltage Measurement... 10:40:23 Voltage Offset Correction: v_off_ini = 802.601 uV, v_off_fin = 809.497 uV 10:40:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.165 uVs 10:40:23 Integrated Voltage Measurement... 10:40:32 Voltage Offset Correction: v_off_ini = 826.703 uV, v_off_fin = 813.137 uV 10:40:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.506 uVs 10:40:32 Integrated Voltage Measurement... 10:40:41 Voltage Offset Correction: v_off_ini = 828.962 uV, v_off_fin = 820.755 uV 10:40:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.848 uVs 10:40:46 I1X Average and RMS of Measurements VT = -78.672 +- 5.692 uVs I1X = 15.734 +- 1.138 uTm 10:40:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:40:52 Integrated Voltage Measurement... 10:41:01 Voltage Offset Correction: v_off_ini = 796.165 uV, v_off_fin = 778.895 uV 10:41:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.276 uVs 10:41:01 Integrated Voltage Measurement... 10:41:10 Voltage Offset Correction: v_off_ini = 794.696 uV, v_off_fin = 809.195 uV 10:41:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.611 uVs 10:41:10 Integrated Voltage Measurement... 10:41:19 Voltage Offset Correction: v_off_ini = 794.782 uV, v_off_fin = 803.278 uV 10:41:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.987 uVs 10:41:19 Integrated Voltage Measurement... 10:41:28 Voltage Offset Correction: v_off_ini = 810.554 uV, v_off_fin = 810.040 uV 10:41:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.317 uVs 10:41:28 Integrated Voltage Measurement... 10:41:37 Voltage Offset Correction: v_off_ini = 803.264 uV, v_off_fin = 785.321 uV 10:41:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.856 uVs 10:41:37 Integrated Voltage Measurement... 10:41:46 Voltage Offset Correction: v_off_ini = 787.723 uV, v_off_fin = 822.562 uV 10:41:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.687 uVs 10:41:51 I1Y Average and RMS of Measurements VT = -250.956 +- 10.061 uVs I1Y = -50.191 +- 2.012 uTm 10:41:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:41:58 Integrated Voltage Measurement... 10:42:07 Voltage Offset Correction: v_off_ini = 807.428 uV, v_off_fin = 797.850 uV 10:42:07 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -88.810 uVs 10:42:07 Integrated Voltage Measurement... 10:42:16 Voltage Offset Correction: v_off_ini = 804.794 uV, v_off_fin = 799.208 uV 10:42:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.429 uVs 10:42:17 Integrated Voltage Measurement... 10:42:26 Voltage Offset Correction: v_off_ini = 784.768 uV, v_off_fin = 782.635 uV 10:42:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.165 uVs 10:42:26 Integrated Voltage Measurement... 10:42:35 Voltage Offset Correction: v_off_ini = 796.426 uV, v_off_fin = 809.695 uV 10:42:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.541 uVs 10:42:35 Integrated Voltage Measurement... 10:42:44 Voltage Offset Correction: v_off_ini = 774.187 uV, v_off_fin = 779.920 uV 10:42:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.644 uVs 10:42:44 Integrated Voltage Measurement... 10:42:53 Voltage Offset Correction: v_off_ini = 799.113 uV, v_off_fin = 803.778 uV 10:42:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.733 uVs 10:42:55 I2X Average and RMS of Measurements VT = -83.720 +- 7.121 uVs I2X = 7.702 +- 0.655 uTm^2 10:43:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:43:03 Integrated Voltage Measurement... 10:43:12 Voltage Offset Correction: v_off_ini = 794.955 uV, v_off_fin = 781.023 uV 10:43:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.353 uVs 10:43:12 Integrated Voltage Measurement... 10:43:21 Voltage Offset Correction: v_off_ini = 794.487 uV, v_off_fin = 780.894 uV 10:43:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.750 uVs 10:43:21 Integrated Voltage Measurement... 10:43:30 Voltage Offset Correction: v_off_ini = 781.221 uV, v_off_fin = 790.139 uV 10:43:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.856 uVs 10:43:30 Integrated Voltage Measurement... 10:43:39 Voltage Offset Correction: v_off_ini = 828.350 uV, v_off_fin = 826.369 uV 10:43:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.833 uVs 10:43:39 Integrated Voltage Measurement... 10:43:48 Voltage Offset Correction: v_off_ini = 787.525 uV, v_off_fin = 809.771 uV 10:43:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.808 uVs 10:43:48 Integrated Voltage Measurement... 10:43:57 Voltage Offset Correction: v_off_ini = 805.223 uV, v_off_fin = 813.614 uV 10:43:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.478 uVs 10:44:00 I2Y Average and RMS of Measurements VT = -273.680 +- 5.522 uVs I2Y = -25.179 +- 0.508 uTm^2 10:44:04 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:44:08 Integrated Voltage Measurement... 10:44:17 Voltage Offset Correction: v_off_ini = 798.329 uV, v_off_fin = 792.213 uV 10:44:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -98.673 uVs 10:44:17 Integrated Voltage Measurement... 10:44:26 Voltage Offset Correction: v_off_ini = 779.370 uV, v_off_fin = 780.768 uV 10:44:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.708 uVs 10:44:26 Integrated Voltage Measurement... 10:44:35 Voltage Offset Correction: v_off_ini = 786.206 uV, v_off_fin = 782.026 uV 10:44:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.600 uVs 10:44:35 Integrated Voltage Measurement... 10:44:44 Voltage Offset Correction: v_off_ini = 790.734 uV, v_off_fin = 799.994 uV 10:44:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.047 uVs 10:44:44 Integrated Voltage Measurement... 10:44:53 Voltage Offset Correction: v_off_ini = 786.447 uV, v_off_fin = 798.056 uV 10:44:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.912 uVs 10:44:53 Integrated Voltage Measurement... 10:45:02 Voltage Offset Correction: v_off_ini = 814.313 uV, v_off_fin = 797.989 uV 10:45:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.040 uVs 10:45:07 I1X Average and RMS of Measurements VT = -79.497 +- 4.139 uVs I1X = 15.900 +- 0.829 uTm 10:45:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:45:14 Integrated Voltage Measurement... 10:45:22 Voltage Offset Correction: v_off_ini = 813.727 uV, v_off_fin = 777.539 uV 10:45:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.180 uVs 10:45:23 Integrated Voltage Measurement... 10:45:31 Voltage Offset Correction: v_off_ini = 795.535 uV, v_off_fin = 803.721 uV 10:45:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.765 uVs 10:45:32 Integrated Voltage Measurement... 10:45:40 Voltage Offset Correction: v_off_ini = 786.022 uV, v_off_fin = 797.940 uV 10:45:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.336 uVs 10:45:41 Integrated Voltage Measurement... 10:45:49 Voltage Offset Correction: v_off_ini = 805.524 uV, v_off_fin = 820.103 uV 10:45:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.877 uVs 10:45:50 Integrated Voltage Measurement... 10:45:59 Voltage Offset Correction: v_off_ini = 807.483 uV, v_off_fin = 797.877 uV 10:45:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.606 uVs 10:45:59 Integrated Voltage Measurement... 10:46:08 Voltage Offset Correction: v_off_ini = 817.296 uV, v_off_fin = 817.661 uV 10:46:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.816 uVs 10:46:12 I1Y Average and RMS of Measurements VT = -255.430 +- 9.978 uVs I1Y = -51.086 +- 1.996 uTm 10:46:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:46:20 Integrated Voltage Measurement... 10:46:28 Voltage Offset Correction: v_off_ini = 822.292 uV, v_off_fin = 817.528 uV 10:46:29 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -83.868 uVs 10:46:29 Integrated Voltage Measurement... 10:46:38 Voltage Offset Correction: v_off_ini = 803.768 uV, v_off_fin = 800.464 uV 10:46:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.556 uVs 10:46:38 Integrated Voltage Measurement... 10:46:47 Voltage Offset Correction: v_off_ini = 807.179 uV, v_off_fin = 790.994 uV 10:46:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.085 uVs 10:46:47 Integrated Voltage Measurement... 10:46:56 Voltage Offset Correction: v_off_ini = 813.545 uV, v_off_fin = 818.112 uV 10:46:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.167 uVs 10:46:56 Integrated Voltage Measurement... 10:47:05 Voltage Offset Correction: v_off_ini = 797.987 uV, v_off_fin = 781.825 uV 10:47:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.261 uVs 10:47:05 Integrated Voltage Measurement... 10:47:14 Voltage Offset Correction: v_off_ini = 777.567 uV, v_off_fin = 811.218 uV 10:47:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.269 uVs 10:47:16 I2X Average and RMS of Measurements VT = -76.201 +- 0.663 uVs I2X = 7.010 +- 0.060 uTm^2 10:47:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:47:24 Integrated Voltage Measurement... 10:47:33 Voltage Offset Correction: v_off_ini = 814.048 uV, v_off_fin = 822.512 uV 10:47:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.885 uVs 10:47:33 Integrated Voltage Measurement... 10:47:42 Voltage Offset Correction: v_off_ini = 814.603 uV, v_off_fin = 800.973 uV 10:47:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.828 uVs 10:47:42 Integrated Voltage Measurement... 10:47:51 Voltage Offset Correction: v_off_ini = 789.939 uV, v_off_fin = 802.945 uV 10:47:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.625 uVs 10:47:51 Integrated Voltage Measurement... 10:48:00 Voltage Offset Correction: v_off_ini = 803.136 uV, v_off_fin = 815.076 uV 10:48:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.439 uVs 10:48:00 Integrated Voltage Measurement... 10:48:09 Voltage Offset Correction: v_off_ini = 824.026 uV, v_off_fin = 837.354 uV 10:48:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.201 uVs 10:48:09 Integrated Voltage Measurement... 10:48:18 Voltage Offset Correction: v_off_ini = 829.221 uV, v_off_fin = 832.142 uV 10:48:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.397 uVs 10:48:21 I2Y Average and RMS of Measurements VT = -276.062 +- 3.915 uVs I2Y = -25.398 +- 0.360 uTm^2 10:48:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:48:29 Integrated Voltage Measurement... 10:48:38 Voltage Offset Correction: v_off_ini = 833.862 uV, v_off_fin = 814.592 uV 10:48:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.065 uVs 10:48:38 Integrated Voltage Measurement... 10:48:47 Voltage Offset Correction: v_off_ini = 827.479 uV, v_off_fin = 798.400 uV 10:48:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.164 uVs 10:48:48 Integrated Voltage Measurement... 10:48:56 Voltage Offset Correction: v_off_ini = 807.080 uV, v_off_fin = 792.416 uV 10:48:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.573 uVs 10:48:57 Integrated Voltage Measurement... 10:49:06 Voltage Offset Correction: v_off_ini = 804.837 uV, v_off_fin = 794.590 uV 10:49:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.591 uVs 10:49:06 Integrated Voltage Measurement... 10:49:15 Voltage Offset Correction: v_off_ini = 802.454 uV, v_off_fin = 791.499 uV 10:49:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.287 uVs 10:49:15 Integrated Voltage Measurement... 10:49:24 Voltage Offset Correction: v_off_ini = 800.898 uV, v_off_fin = 802.507 uV 10:49:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.828 uVs 10:49:28 I1X Average and RMS of Measurements VT = -76.585 +- 6.329 uVs I1X = 15.317 +- 1.266 uTm 10:49:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:49:35 Integrated Voltage Measurement... 10:49:44 Voltage Offset Correction: v_off_ini = 836.548 uV, v_off_fin = 821.625 uV 10:49:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.529 uVs 10:49:44 Integrated Voltage Measurement... 10:49:53 Voltage Offset Correction: v_off_ini = 829.352 uV, v_off_fin = 826.176 uV 10:49:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.522 uVs 10:49:53 Integrated Voltage Measurement... 10:50:02 Voltage Offset Correction: v_off_ini = 816.701 uV, v_off_fin = 812.003 uV 10:50:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.767 uVs 10:50:02 Integrated Voltage Measurement... 10:50:11 Voltage Offset Correction: v_off_ini = 822.710 uV, v_off_fin = 826.588 uV 10:50:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.699 uVs 10:50:11 Integrated Voltage Measurement... 10:50:20 Voltage Offset Correction: v_off_ini = 810.031 uV, v_off_fin = 791.811 uV 10:50:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.223 uVs 10:50:20 Integrated Voltage Measurement... 10:50:29 Voltage Offset Correction: v_off_ini = 805.494 uV, v_off_fin = 811.596 uV 10:50:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.997 uVs 10:50:33 I1Y Average and RMS of Measurements VT = -232.623 +- 2.365 uVs I1Y = -46.525 +- 0.473 uTm 10:50:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:50:41 Integrated Voltage Measurement... 10:50:50 Voltage Offset Correction: v_off_ini = 838.296 uV, v_off_fin = 825.866 uV 10:50:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -51.985 uVs 10:50:50 Integrated Voltage Measurement... 10:50:59 Voltage Offset Correction: v_off_ini = 841.863 uV, v_off_fin = 844.968 uV 10:50:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.302 uVs 10:50:59 Integrated Voltage Measurement... 10:51:08 Voltage Offset Correction: v_off_ini = 820.306 uV, v_off_fin = 808.014 uV 10:51:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.590 uVs 10:51:08 Integrated Voltage Measurement... 10:51:17 Voltage Offset Correction: v_off_ini = 828.234 uV, v_off_fin = 837.127 uV 10:51:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.551 uVs 10:51:17 Integrated Voltage Measurement... 10:51:26 Voltage Offset Correction: v_off_ini = 839.422 uV, v_off_fin = 822.982 uV 10:51:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.823 uVs 10:51:26 Integrated Voltage Measurement... 10:51:35 Voltage Offset Correction: v_off_ini = 828.362 uV, v_off_fin = 846.173 uV 10:51:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.356 uVs 10:51:37 I2X Average and RMS of Measurements VT = -61.435 +- 3.094 uVs I2X = 5.652 +- 0.284 uTm^2 10:51:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:51:45 Integrated Voltage Measurement... 10:51:54 Voltage Offset Correction: v_off_ini = 826.351 uV, v_off_fin = 832.722 uV 10:51:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.788 uVs 10:51:54 Integrated Voltage Measurement... 10:52:03 Voltage Offset Correction: v_off_ini = 841.018 uV, v_off_fin = 850.084 uV 10:52:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.199 uVs 10:52:03 Integrated Voltage Measurement... 10:52:12 Voltage Offset Correction: v_off_ini = 852.515 uV, v_off_fin = 827.394 uV 10:52:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.251 uVs 10:52:12 Integrated Voltage Measurement... 10:52:21 Voltage Offset Correction: v_off_ini = 835.191 uV, v_off_fin = 833.245 uV 10:52:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.803 uVs 10:52:21 Integrated Voltage Measurement... 10:52:30 Voltage Offset Correction: v_off_ini = 837.175 uV, v_off_fin = 843.737 uV 10:52:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.660 uVs 10:52:30 Integrated Voltage Measurement... 10:52:39 Voltage Offset Correction: v_off_ini = 846.819 uV, v_off_fin = 851.310 uV 10:52:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.643 uVs 10:52:42 I2Y Average and RMS of Measurements VT = -262.891 +- 1.875 uVs I2Y = -24.186 +- 0.172 uTm^2 10:52:46 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:52:51 Integrated Voltage Measurement... 10:53:00 Voltage Offset Correction: v_off_ini = 851.314 uV, v_off_fin = 827.143 uV 10:53:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.196 uVs 10:53:00 Integrated Voltage Measurement... 10:53:09 Voltage Offset Correction: v_off_ini = 827.892 uV, v_off_fin = 828.845 uV 10:53:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.332 uVs 10:53:09 Integrated Voltage Measurement... 10:53:18 Voltage Offset Correction: v_off_ini = 837.186 uV, v_off_fin = 837.461 uV 10:53:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.658 uVs 10:53:18 Integrated Voltage Measurement... 10:53:27 Voltage Offset Correction: v_off_ini = 839.792 uV, v_off_fin = 848.756 uV 10:53:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.683 uVs 10:53:27 Integrated Voltage Measurement... 10:53:36 Voltage Offset Correction: v_off_ini = 831.364 uV, v_off_fin = 814.706 uV 10:53:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.282 uVs 10:53:36 Integrated Voltage Measurement... 10:53:45 Voltage Offset Correction: v_off_ini = 802.448 uV, v_off_fin = 831.380 uV 10:53:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.108 uVs 10:53:49 I1X Average and RMS of Measurements VT = -69.710 +- 4.780 uVs I1X = 13.942 +- 0.956 uTm 10:53:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:53:56 Integrated Voltage Measurement... 10:54:05 Voltage Offset Correction: v_off_ini = 830.467 uV, v_off_fin = 833.145 uV 10:54:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.769 uVs 10:54:05 Integrated Voltage Measurement... 10:54:14 Voltage Offset Correction: v_off_ini = 824.875 uV, v_off_fin = 835.272 uV 10:54:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.525 uVs 10:54:14 Integrated Voltage Measurement... 10:54:23 Voltage Offset Correction: v_off_ini = 814.054 uV, v_off_fin = 824.398 uV 10:54:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.390 uVs 10:54:23 Integrated Voltage Measurement... 10:54:32 Voltage Offset Correction: v_off_ini = 835.860 uV, v_off_fin = 834.534 uV 10:54:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.510 uVs 10:54:32 Integrated Voltage Measurement... 10:54:41 Voltage Offset Correction: v_off_ini = 829.802 uV, v_off_fin = 826.449 uV 10:54:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.755 uVs 10:54:41 Integrated Voltage Measurement... 10:54:50 Voltage Offset Correction: v_off_ini = 833.894 uV, v_off_fin = 836.540 uV 10:54:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.008 uVs 10:54:54 I1Y Average and RMS of Measurements VT = -217.160 +- 5.291 uVs I1Y = -43.432 +- 1.058 uTm 10:54:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:55:02 Integrated Voltage Measurement... 10:55:11 Voltage Offset Correction: v_off_ini = 841.389 uV, v_off_fin = 850.434 uV 10:55:11 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -62.689 uVs 10:55:11 Integrated Voltage Measurement... 10:55:20 Voltage Offset Correction: v_off_ini = 861.264 uV, v_off_fin = 853.369 uV 10:55:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 67.296 uVs 10:55:20 Integrated Voltage Measurement... 10:55:29 Voltage Offset Correction: v_off_ini = 833.925 uV, v_off_fin = 824.163 uV 10:55:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.012 uVs 10:55:29 Integrated Voltage Measurement... 10:55:38 Voltage Offset Correction: v_off_ini = 831.281 uV, v_off_fin = 836.908 uV 10:55:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 70.880 uVs 10:55:38 Integrated Voltage Measurement... 10:55:47 Voltage Offset Correction: v_off_ini = 825.310 uV, v_off_fin = 815.646 uV 10:55:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.663 uVs 10:55:47 Integrated Voltage Measurement... 10:55:56 Voltage Offset Correction: v_off_ini = 819.767 uV, v_off_fin = 840.258 uV 10:55:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.426 uVs 10:55:58 I2X Average and RMS of Measurements VT = -56.661 +- 5.891 uVs I2X = 5.213 +- 0.542 uTm^2 10:56:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:56:06 Integrated Voltage Measurement... 10:56:15 Voltage Offset Correction: v_off_ini = 831.857 uV, v_off_fin = 833.589 uV 10:56:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.928 uVs 10:56:15 Integrated Voltage Measurement... 10:56:24 Voltage Offset Correction: v_off_ini = 846.480 uV, v_off_fin = 858.981 uV 10:56:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.610 uVs 10:56:24 Integrated Voltage Measurement... 10:56:33 Voltage Offset Correction: v_off_ini = 844.725 uV, v_off_fin = 847.774 uV 10:56:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.236 uVs 10:56:33 Integrated Voltage Measurement... 10:56:42 Voltage Offset Correction: v_off_ini = 847.055 uV, v_off_fin = 854.283 uV 10:56:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.395 uVs 10:56:42 Integrated Voltage Measurement... 10:56:51 Voltage Offset Correction: v_off_ini = 857.170 uV, v_off_fin = 849.819 uV 10:56:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.735 uVs 10:56:51 Integrated Voltage Measurement... 10:57:00 Voltage Offset Correction: v_off_ini = 848.103 uV, v_off_fin = 869.719 uV 10:57:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.206 uVs 10:57:03 I2Y Average and RMS of Measurements VT = -244.518 +- 3.618 uVs I2Y = -22.496 +- 0.333 uTm^2 10:57:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:57:12 Integrated Voltage Measurement... 10:57:21 Voltage Offset Correction: v_off_ini = 874.243 uV, v_off_fin = 877.845 uV 10:57:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.565 uVs 10:57:21 Integrated Voltage Measurement... 10:57:30 Voltage Offset Correction: v_off_ini = 870.651 uV, v_off_fin = 874.128 uV 10:57:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.428 uVs 10:57:30 Integrated Voltage Measurement... 10:57:39 Voltage Offset Correction: v_off_ini = 868.770 uV, v_off_fin = 887.964 uV 10:57:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -56.359 uVs 10:57:39 Integrated Voltage Measurement... 10:57:48 Voltage Offset Correction: v_off_ini = 899.224 uV, v_off_fin = 887.967 uV 10:57:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 49.019 uVs 10:57:48 Integrated Voltage Measurement... 10:57:57 Voltage Offset Correction: v_off_ini = 891.174 uV, v_off_fin = 883.532 uV 10:57:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.833 uVs 10:57:57 Integrated Voltage Measurement... 10:58:06 Voltage Offset Correction: v_off_ini = 908.004 uV, v_off_fin = 900.787 uV 10:58:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.916 uVs 10:58:10 I1X Average and RMS of Measurements VT = -68.686 +- 14.101 uVs I1X = 13.737 +- 2.821 uTm 10:58:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:58:17 Integrated Voltage Measurement... 10:58:26 Voltage Offset Correction: v_off_ini = 892.729 uV, v_off_fin = 885.621 uV 10:58:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.453 uVs 10:58:26 Integrated Voltage Measurement... 10:58:35 Voltage Offset Correction: v_off_ini = 906.177 uV, v_off_fin = 932.347 uV 10:58:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.585 uVs 10:58:35 Integrated Voltage Measurement... 10:58:44 Voltage Offset Correction: v_off_ini = 894.599 uV, v_off_fin = 884.245 uV 10:58:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.677 uVs 10:58:44 Integrated Voltage Measurement... 10:58:53 Voltage Offset Correction: v_off_ini = 905.747 uV, v_off_fin = 915.882 uV 10:58:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.841 uVs 10:58:53 Integrated Voltage Measurement... 10:59:02 Voltage Offset Correction: v_off_ini = 922.330 uV, v_off_fin = 909.958 uV 10:59:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.384 uVs 10:59:02 Integrated Voltage Measurement... 10:59:11 Voltage Offset Correction: v_off_ini = 914.133 uV, v_off_fin = 911.747 uV 10:59:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.978 uVs 10:59:15 I1Y Average and RMS of Measurements VT = -209.486 +- 4.225 uVs I1Y = -41.897 +- 0.845 uTm 10:59:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:59:23 Integrated Voltage Measurement... 10:59:32 Voltage Offset Correction: v_off_ini = 890.627 uV, v_off_fin = 856.801 uV 10:59:32 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -83.999 uVs 10:59:32 Integrated Voltage Measurement... 10:59:41 Voltage Offset Correction: v_off_ini = 879.404 uV, v_off_fin = 891.934 uV 10:59:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.354 uVs 10:59:41 Integrated Voltage Measurement... 10:59:50 Voltage Offset Correction: v_off_ini = 890.058 uV, v_off_fin = 876.641 uV 10:59:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.262 uVs 10:59:50 Integrated Voltage Measurement... 10:59:59 Voltage Offset Correction: v_off_ini = 898.049 uV, v_off_fin = 909.086 uV 10:59:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.907 uVs 10:59:59 Integrated Voltage Measurement... 11:00:08 Voltage Offset Correction: v_off_ini = 906.045 uV, v_off_fin = 900.935 uV 11:00:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.423 uVs 11:00:08 Integrated Voltage Measurement... 11:00:17 Voltage Offset Correction: v_off_ini = 907.578 uV, v_off_fin = 914.354 uV 11:00:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.516 uVs 11:00:19 I2X Average and RMS of Measurements VT = -67.410 +- 10.448 uVs I2X = 6.202 +- 0.961 uTm^2 11:00:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:00:27 Integrated Voltage Measurement... 11:00:36 Voltage Offset Correction: v_off_ini = 866.250 uV, v_off_fin = 874.843 uV 11:00:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.766 uVs 11:00:36 Integrated Voltage Measurement... 11:00:45 Voltage Offset Correction: v_off_ini = 889.490 uV, v_off_fin = 880.223 uV 11:00:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.867 uVs 11:00:45 Integrated Voltage Measurement... 11:00:54 Voltage Offset Correction: v_off_ini = 884.363 uV, v_off_fin = 901.922 uV 11:00:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.230 uVs 11:00:54 Integrated Voltage Measurement... 11:01:03 Voltage Offset Correction: v_off_ini = 887.238 uV, v_off_fin = 881.164 uV 11:01:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.886 uVs 11:01:03 Integrated Voltage Measurement... 11:01:12 Voltage Offset Correction: v_off_ini = 882.962 uV, v_off_fin = 896.236 uV 11:01:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.902 uVs 11:01:12 Integrated Voltage Measurement... 11:01:21 Voltage Offset Correction: v_off_ini = 881.116 uV, v_off_fin = 886.177 uV 11:01:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.505 uVs 11:01:24 I2Y Average and RMS of Measurements VT = -219.026 +- 7.940 uVs I2Y = -20.150 +- 0.730 uTm^2 11:01:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:01:36 Integrated Voltage Measurement... 11:01:45 Voltage Offset Correction: v_off_ini = 881.755 uV, v_off_fin = 870.589 uV 11:01:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -36.596 uVs 11:01:45 Integrated Voltage Measurement... 11:01:54 Voltage Offset Correction: v_off_ini = 875.496 uV, v_off_fin = 860.311 uV 11:01:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.911 uVs 11:01:54 Integrated Voltage Measurement... 11:02:03 Voltage Offset Correction: v_off_ini = 850.034 uV, v_off_fin = 868.506 uV 11:02:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.700 uVs 11:02:03 Integrated Voltage Measurement... 11:02:12 Voltage Offset Correction: v_off_ini = 887.198 uV, v_off_fin = 883.395 uV 11:02:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.381 uVs 11:02:12 Integrated Voltage Measurement... 11:02:21 Voltage Offset Correction: v_off_ini = 887.459 uV, v_off_fin = 906.568 uV 11:02:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.532 uVs 11:02:21 Integrated Voltage Measurement... 11:02:30 Voltage Offset Correction: v_off_ini = 893.669 uV, v_off_fin = 885.441 uV 11:02:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.215 uVs 11:02:34 I1X Average and RMS of Measurements VT = -47.556 +- 3.633 uVs I1X = 9.511 +- 0.727 uTm 11:02:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:02:41 Integrated Voltage Measurement... 11:02:50 Voltage Offset Correction: v_off_ini = 879.487 uV, v_off_fin = 874.850 uV 11:02:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.406 uVs 11:02:50 Integrated Voltage Measurement... 11:02:59 Voltage Offset Correction: v_off_ini = 895.453 uV, v_off_fin = 894.867 uV 11:02:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.326 uVs 11:02:59 Integrated Voltage Measurement... 11:03:08 Voltage Offset Correction: v_off_ini = 893.245 uV, v_off_fin = 866.498 uV 11:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.480 uVs 11:03:08 Integrated Voltage Measurement... 11:03:17 Voltage Offset Correction: v_off_ini = 889.681 uV, v_off_fin = 895.559 uV 11:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.379 uVs 11:03:17 Integrated Voltage Measurement... 11:03:26 Voltage Offset Correction: v_off_ini = 875.830 uV, v_off_fin = 858.551 uV 11:03:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.572 uVs 11:03:26 Integrated Voltage Measurement... 11:03:35 Voltage Offset Correction: v_off_ini = 870.387 uV, v_off_fin = 902.161 uV 11:03:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.066 uVs 11:03:39 I1Y Average and RMS of Measurements VT = -246.538 +- 4.530 uVs I1Y = -49.308 +- 0.906 uTm 11:03:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:03:44 Integrated Voltage Measurement... 11:03:53 Voltage Offset Correction: v_off_ini = 906.630 uV, v_off_fin = 889.297 uV 11:03:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.654 uVs 11:03:53 Integrated Voltage Measurement... 11:04:02 Voltage Offset Correction: v_off_ini = 902.235 uV, v_off_fin = 903.893 uV 11:04:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.046 uVs 11:04:02 Integrated Voltage Measurement... 11:04:11 Voltage Offset Correction: v_off_ini = 911.388 uV, v_off_fin = 913.576 uV 11:04:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.028 uVs 11:04:11 Integrated Voltage Measurement... 11:04:20 Voltage Offset Correction: v_off_ini = 925.651 uV, v_off_fin = 928.414 uV 11:04:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.557 uVs 11:04:20 Integrated Voltage Measurement... 11:04:29 Voltage Offset Correction: v_off_ini = 914.690 uV, v_off_fin = 902.341 uV 11:04:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.290 uVs 11:04:29 Integrated Voltage Measurement... 11:04:38 Voltage Offset Correction: v_off_ini = 898.608 uV, v_off_fin = 919.328 uV 11:04:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.660 uVs 11:04:41 I2X Average and RMS of Measurements VT = -46.873 +- 8.117 uVs I2X = 4.312 +- 0.747 uTm^2 11:04:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:04:46 Integrated Voltage Measurement... 11:04:55 Voltage Offset Correction: v_off_ini = 923.831 uV, v_off_fin = 925.262 uV 11:04:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.226 uVs 11:04:55 Integrated Voltage Measurement... 11:05:04 Voltage Offset Correction: v_off_ini = 900.385 uV, v_off_fin = 929.984 uV 11:05:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.306 uVs 11:05:04 Integrated Voltage Measurement... 11:05:13 Voltage Offset Correction: v_off_ini = 933.026 uV, v_off_fin = 939.613 uV 11:05:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.056 uVs 11:05:13 Integrated Voltage Measurement... 11:05:22 Voltage Offset Correction: v_off_ini = 949.129 uV, v_off_fin = 950.491 uV 11:05:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.303 uVs 11:05:22 Integrated Voltage Measurement... 11:05:31 Voltage Offset Correction: v_off_ini = 922.682 uV, v_off_fin = 938.465 uV 11:05:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.477 uVs 11:05:31 Integrated Voltage Measurement... 11:05:40 Voltage Offset Correction: v_off_ini = 938.532 uV, v_off_fin = 931.111 uV 11:05:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.394 uVs 11:05:43 I2Y Average and RMS of Measurements VT = -256.294 +- 8.503 uVs I2Y = -23.579 +- 0.782 uTm^2 11:05:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:05:51 Integrated Voltage Measurement... 11:06:00 Voltage Offset Correction: v_off_ini = 932.988 uV, v_off_fin = 922.405 uV 11:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -51.516 uVs 11:06:00 Integrated Voltage Measurement... 11:06:09 Voltage Offset Correction: v_off_ini = 893.305 uV, v_off_fin = 902.486 uV 11:06:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.545 uVs 11:06:09 Integrated Voltage Measurement... 11:06:18 Voltage Offset Correction: v_off_ini = 924.484 uV, v_off_fin = 918.879 uV 11:06:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.162 uVs 11:06:18 Integrated Voltage Measurement... 11:06:27 Voltage Offset Correction: v_off_ini = 909.210 uV, v_off_fin = 920.896 uV 11:06:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.881 uVs 11:06:27 Integrated Voltage Measurement... 11:06:36 Voltage Offset Correction: v_off_ini = 935.076 uV, v_off_fin = 941.252 uV 11:06:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.578 uVs 11:06:36 Integrated Voltage Measurement... 11:06:45 Voltage Offset Correction: v_off_ini = 941.196 uV, v_off_fin = 947.079 uV 11:06:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.812 uVs 11:06:49 I1X Average and RMS of Measurements VT = -51.083 +- 12.866 uVs I1X = 10.217 +- 2.573 uTm 11:06:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:06:56 Integrated Voltage Measurement... 11:07:05 Voltage Offset Correction: v_off_ini = 923.292 uV, v_off_fin = 930.036 uV 11:07:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.325 uVs 11:07:05 Integrated Voltage Measurement... 11:07:14 Voltage Offset Correction: v_off_ini = 917.669 uV, v_off_fin = 929.210 uV 11:07:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.963 uVs 11:07:14 Integrated Voltage Measurement... 11:07:23 Voltage Offset Correction: v_off_ini = 918.191 uV, v_off_fin = 910.863 uV 11:07:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.932 uVs 11:07:23 Integrated Voltage Measurement... 11:07:32 Voltage Offset Correction: v_off_ini = 935.968 uV, v_off_fin = 941.266 uV 11:07:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.111 uVs 11:07:32 Integrated Voltage Measurement... 11:07:41 Voltage Offset Correction: v_off_ini = 930.010 uV, v_off_fin = 919.132 uV 11:07:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.939 uVs 11:07:41 Integrated Voltage Measurement... 11:07:50 Voltage Offset Correction: v_off_ini = 924.058 uV, v_off_fin = 935.092 uV 11:07:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.242 uVs 11:07:54 I1Y Average and RMS of Measurements VT = -238.252 +- 1.228 uVs I1Y = -47.650 +- 0.246 uTm 11:07:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:07:59 Integrated Voltage Measurement... 11:08:08 Voltage Offset Correction: v_off_ini = 934.380 uV, v_off_fin = 923.978 uV 11:08:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.059 uVs 11:08:08 Integrated Voltage Measurement... 11:08:17 Voltage Offset Correction: v_off_ini = 898.529 uV, v_off_fin = 920.641 uV 11:08:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.059 uVs 11:08:18 Integrated Voltage Measurement... 11:08:27 Voltage Offset Correction: v_off_ini = 913.141 uV, v_off_fin = 907.781 uV 11:08:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.356 uVs 11:08:27 Integrated Voltage Measurement... 11:08:36 Voltage Offset Correction: v_off_ini = 902.099 uV, v_off_fin = 915.800 uV 11:08:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.441 uVs 11:08:36 Integrated Voltage Measurement... 11:08:45 Voltage Offset Correction: v_off_ini = 916.356 uV, v_off_fin = 900.579 uV 11:08:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.296 uVs 11:08:45 Integrated Voltage Measurement... 11:08:54 Voltage Offset Correction: v_off_ini = 905.467 uV, v_off_fin = 899.544 uV 11:08:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.573 uVs 11:08:56 I2X Average and RMS of Measurements VT = -66.964 +- 6.448 uVs I2X = 6.161 +- 0.593 uTm^2 11:08:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:09:01 Integrated Voltage Measurement... 11:09:10 Voltage Offset Correction: v_off_ini = 886.467 uV, v_off_fin = 882.441 uV 11:09:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.172 uVs 11:09:10 Integrated Voltage Measurement... 11:09:19 Voltage Offset Correction: v_off_ini = 878.274 uV, v_off_fin = 890.006 uV 11:09:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.757 uVs 11:09:19 Integrated Voltage Measurement... 11:09:28 Voltage Offset Correction: v_off_ini = 900.718 uV, v_off_fin = 902.098 uV 11:09:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.269 uVs 11:09:28 Integrated Voltage Measurement... 11:09:37 Voltage Offset Correction: v_off_ini = 899.716 uV, v_off_fin = 900.022 uV 11:09:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.057 uVs 11:09:37 Integrated Voltage Measurement... 11:09:46 Voltage Offset Correction: v_off_ini = 892.477 uV, v_off_fin = 893.949 uV 11:09:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.123 uVs 11:09:46 Integrated Voltage Measurement... 11:09:55 Voltage Offset Correction: v_off_ini = 888.075 uV, v_off_fin = 886.798 uV 11:09:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.295 uVs 11:09:58 I2Y Average and RMS of Measurements VT = -255.112 +- 5.196 uVs I2Y = -23.470 +- 0.478 uTm^2 11:10:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:10:06 Integrated Voltage Measurement... 11:10:15 Voltage Offset Correction: v_off_ini = 898.595 uV, v_off_fin = 886.517 uV 11:10:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.039 uVs 11:10:15 Integrated Voltage Measurement... 11:10:24 Voltage Offset Correction: v_off_ini = 878.849 uV, v_off_fin = 886.478 uV 11:10:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 40.337 uVs 11:10:24 Integrated Voltage Measurement... 11:10:33 Voltage Offset Correction: v_off_ini = 891.851 uV, v_off_fin = 890.185 uV 11:10:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.914 uVs 11:10:33 Integrated Voltage Measurement... 11:10:42 Voltage Offset Correction: v_off_ini = 884.492 uV, v_off_fin = 891.463 uV 11:10:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.725 uVs 11:10:42 Integrated Voltage Measurement... 11:10:51 Voltage Offset Correction: v_off_ini = 892.563 uV, v_off_fin = 876.660 uV 11:10:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.516 uVs 11:10:51 Integrated Voltage Measurement... 11:11:00 Voltage Offset Correction: v_off_ini = 885.349 uV, v_off_fin = 874.811 uV 11:11:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.990 uVs 11:11:05 I1X Average and RMS of Measurements VT = -63.087 +- 8.339 uVs I1X = 12.617 +- 1.668 uTm 11:11:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:11:11 Integrated Voltage Measurement... 11:11:20 Voltage Offset Correction: v_off_ini = 876.371 uV, v_off_fin = 855.915 uV 11:11:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.958 uVs 11:11:20 Integrated Voltage Measurement... 11:11:29 Voltage Offset Correction: v_off_ini = 853.136 uV, v_off_fin = 867.287 uV 11:11:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.002 uVs 11:11:29 Integrated Voltage Measurement... 11:11:38 Voltage Offset Correction: v_off_ini = 873.713 uV, v_off_fin = 851.230 uV 11:11:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.286 uVs 11:11:38 Integrated Voltage Measurement... 11:11:47 Voltage Offset Correction: v_off_ini = 856.220 uV, v_off_fin = 886.102 uV 11:11:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.954 uVs 11:11:47 Integrated Voltage Measurement... 11:11:56 Voltage Offset Correction: v_off_ini = 865.366 uV, v_off_fin = 864.592 uV 11:11:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.396 uVs 11:11:56 Integrated Voltage Measurement... 11:12:05 Voltage Offset Correction: v_off_ini = 878.532 uV, v_off_fin = 893.761 uV 11:12:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.817 uVs 11:12:10 I1Y Average and RMS of Measurements VT = -235.569 +- 7.789 uVs I1Y = -47.114 +- 1.558 uTm 11:12:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:12:15 Integrated Voltage Measurement... 11:12:24 Voltage Offset Correction: v_off_ini = 875.208 uV, v_off_fin = 865.801 uV 11:12:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.549 uVs 11:12:24 Integrated Voltage Measurement... 11:12:33 Voltage Offset Correction: v_off_ini = 872.114 uV, v_off_fin = 868.322 uV 11:12:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.574 uVs 11:12:33 Integrated Voltage Measurement... 11:12:42 Voltage Offset Correction: v_off_ini = 843.987 uV, v_off_fin = 862.727 uV 11:12:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.520 uVs 11:12:42 Integrated Voltage Measurement... 11:12:51 Voltage Offset Correction: v_off_ini = 894.094 uV, v_off_fin = 904.790 uV 11:12:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.774 uVs 11:12:51 Integrated Voltage Measurement... 11:13:00 Voltage Offset Correction: v_off_ini = 878.939 uV, v_off_fin = 870.253 uV 11:13:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.144 uVs 11:13:00 Integrated Voltage Measurement... 11:13:09 Voltage Offset Correction: v_off_ini = 858.548 uV, v_off_fin = 886.066 uV 11:13:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.101 uVs 11:13:11 I2X Average and RMS of Measurements VT = -60.110 +- 5.496 uVs I2X = 5.530 +- 0.506 uTm^2 11:13:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:13:16 Integrated Voltage Measurement... 11:13:25 Voltage Offset Correction: v_off_ini = 869.500 uV, v_off_fin = 892.116 uV 11:13:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.877 uVs 11:13:25 Integrated Voltage Measurement... 11:13:34 Voltage Offset Correction: v_off_ini = 903.493 uV, v_off_fin = 916.897 uV 11:13:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.060 uVs 11:13:34 Integrated Voltage Measurement... 11:13:43 Voltage Offset Correction: v_off_ini = 905.287 uV, v_off_fin = 918.875 uV 11:13:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.495 uVs 11:13:44 Integrated Voltage Measurement... 11:13:53 Voltage Offset Correction: v_off_ini = 932.564 uV, v_off_fin = 910.886 uV 11:13:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.077 uVs 11:13:53 Integrated Voltage Measurement... 11:14:02 Voltage Offset Correction: v_off_ini = 931.380 uV, v_off_fin = 938.434 uV 11:14:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.735 uVs 11:14:02 Integrated Voltage Measurement... 11:14:11 Voltage Offset Correction: v_off_ini = 927.444 uV, v_off_fin = 926.100 uV 11:14:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.291 uVs 11:14:13 I2Y Average and RMS of Measurements VT = -263.589 +- 7.808 uVs I2Y = -24.250 +- 0.718 uTm^2 11:14:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:14:21 Integrated Voltage Measurement... 11:14:30 Voltage Offset Correction: v_off_ini = 903.286 uV, v_off_fin = 913.034 uV 11:14:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.124 uVs 11:14:30 Integrated Voltage Measurement... 11:14:39 Voltage Offset Correction: v_off_ini = 905.761 uV, v_off_fin = 914.772 uV 11:14:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.117 uVs 11:14:39 Integrated Voltage Measurement... 11:14:48 Voltage Offset Correction: v_off_ini = 913.165 uV, v_off_fin = 923.229 uV 11:14:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.644 uVs 11:14:48 Integrated Voltage Measurement... 11:14:57 Voltage Offset Correction: v_off_ini = 930.707 uV, v_off_fin = 923.075 uV 11:14:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.296 uVs 11:14:57 Integrated Voltage Measurement... 11:15:06 Voltage Offset Correction: v_off_ini = 917.857 uV, v_off_fin = 938.733 uV 11:15:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.086 uVs 11:15:06 Integrated Voltage Measurement... 11:15:15 Voltage Offset Correction: v_off_ini = 924.544 uV, v_off_fin = 927.504 uV 11:15:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.433 uVs 11:15:20 I1X Average and RMS of Measurements VT = -71.117 +- 7.234 uVs I1X = 14.224 +- 1.447 uTm 11:15:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:15:26 Integrated Voltage Measurement... 11:15:35 Voltage Offset Correction: v_off_ini = 901.562 uV, v_off_fin = 904.208 uV 11:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.340 uVs 11:15:35 Integrated Voltage Measurement... 11:15:44 Voltage Offset Correction: v_off_ini = 915.323 uV, v_off_fin = 927.320 uV 11:15:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.677 uVs 11:15:45 Integrated Voltage Measurement... 11:15:53 Voltage Offset Correction: v_off_ini = 915.062 uV, v_off_fin = 890.068 uV 11:15:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.587 uVs 11:15:54 Integrated Voltage Measurement... 11:16:02 Voltage Offset Correction: v_off_ini = 923.998 uV, v_off_fin = 952.166 uV 11:16:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.374 uVs 11:16:03 Integrated Voltage Measurement... 11:16:11 Voltage Offset Correction: v_off_ini = 907.543 uV, v_off_fin = 931.129 uV 11:16:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.913 uVs 11:16:12 Integrated Voltage Measurement... 11:16:20 Voltage Offset Correction: v_off_ini = 926.487 uV, v_off_fin = 932.752 uV 11:16:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.876 uVs 11:16:25 I1Y Average and RMS of Measurements VT = -228.628 +- 3.123 uVs I1Y = -45.722 +- 0.624 uTm 11:16:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:16:30 Integrated Voltage Measurement... 11:16:39 Voltage Offset Correction: v_off_ini = 932.771 uV, v_off_fin = 924.447 uV 11:16:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.261 uVs 11:16:39 Integrated Voltage Measurement... 11:16:48 Voltage Offset Correction: v_off_ini = 939.805 uV, v_off_fin = 947.381 uV 11:16:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.640 uVs 11:16:48 Integrated Voltage Measurement... 11:16:57 Voltage Offset Correction: v_off_ini = 935.615 uV, v_off_fin = 914.867 uV 11:16:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.455 uVs 11:16:57 Integrated Voltage Measurement... 11:17:06 Voltage Offset Correction: v_off_ini = 914.769 uV, v_off_fin = 936.006 uV 11:17:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.316 uVs 11:17:06 Integrated Voltage Measurement... 11:17:15 Voltage Offset Correction: v_off_ini = 911.434 uV, v_off_fin = 908.686 uV 11:17:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.758 uVs 11:17:15 Integrated Voltage Measurement... 11:17:24 Voltage Offset Correction: v_off_ini = 915.064 uV, v_off_fin = 934.207 uV 11:17:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.800 uVs 11:17:26 I2X Average and RMS of Measurements VT = -70.038 +- 0.860 uVs I2X = 6.444 +- 0.079 uTm^2 11:17:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:17:32 Integrated Voltage Measurement... 11:17:41 Voltage Offset Correction: v_off_ini = 926.415 uV, v_off_fin = 950.061 uV 11:17:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.355 uVs 11:17:41 Integrated Voltage Measurement... 11:17:50 Voltage Offset Correction: v_off_ini = 932.114 uV, v_off_fin = 941.593 uV 11:17:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.286 uVs 11:17:50 Integrated Voltage Measurement... 11:17:59 Voltage Offset Correction: v_off_ini = 928.731 uV, v_off_fin = 910.439 uV 11:17:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.703 uVs 11:17:59 Integrated Voltage Measurement... 11:18:08 Voltage Offset Correction: v_off_ini = 927.995 uV, v_off_fin = 937.092 uV 11:18:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.755 uVs 11:18:08 Integrated Voltage Measurement... 11:18:17 Voltage Offset Correction: v_off_ini = 950.788 uV, v_off_fin = 949.396 uV 11:18:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.670 uVs 11:18:17 Integrated Voltage Measurement... 11:18:26 Voltage Offset Correction: v_off_ini = 934.816 uV, v_off_fin = 933.223 uV 11:18:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.448 uVs 11:18:28 I2Y Average and RMS of Measurements VT = -255.703 +- 2.219 uVs I2Y = -23.525 +- 0.204 uTm^2 11:18:32 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:18:36 Integrated Voltage Measurement... 11:18:45 Voltage Offset Correction: v_off_ini = 929.597 uV, v_off_fin = 927.267 uV 11:18:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.966 uVs 11:18:46 Integrated Voltage Measurement... 11:18:54 Voltage Offset Correction: v_off_ini = 926.361 uV, v_off_fin = 941.502 uV 11:18:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.154 uVs 11:18:55 Integrated Voltage Measurement... 11:19:04 Voltage Offset Correction: v_off_ini = 931.644 uV, v_off_fin = 923.417 uV 11:19:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.494 uVs 11:19:04 Integrated Voltage Measurement... 11:19:13 Voltage Offset Correction: v_off_ini = 925.342 uV, v_off_fin = 933.136 uV 11:19:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.490 uVs 11:19:13 Integrated Voltage Measurement... 11:19:22 Voltage Offset Correction: v_off_ini = 929.812 uV, v_off_fin = 931.190 uV 11:19:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.791 uVs 11:19:22 Integrated Voltage Measurement... 11:19:31 Voltage Offset Correction: v_off_ini = 916.550 uV, v_off_fin = 925.405 uV 11:19:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.660 uVs 11:19:35 I1X Average and RMS of Measurements VT = -59.593 +- 12.258 uVs I1X = 11.919 +- 2.452 uTm 11:19:37 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:19:42 Integrated Voltage Measurement... 11:19:51 Voltage Offset Correction: v_off_ini = 902.508 uV, v_off_fin = 901.458 uV 11:19:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.555 uVs 11:19:51 Integrated Voltage Measurement... 11:20:00 Voltage Offset Correction: v_off_ini = 897.909 uV, v_off_fin = 929.356 uV 11:20:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.316 uVs 11:20:00 Integrated Voltage Measurement... 11:20:09 Voltage Offset Correction: v_off_ini = 931.669 uV, v_off_fin = 923.433 uV 11:20:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.683 uVs 11:20:09 Integrated Voltage Measurement... 11:20:18 Voltage Offset Correction: v_off_ini = 935.531 uV, v_off_fin = 952.748 uV 11:20:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.292 uVs 11:20:18 Integrated Voltage Measurement... 11:20:27 Voltage Offset Correction: v_off_ini = 895.882 uV, v_off_fin = 891.318 uV 11:20:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.845 uVs 11:20:27 Integrated Voltage Measurement... 11:20:36 Voltage Offset Correction: v_off_ini = 918.365 uV, v_off_fin = 905.902 uV 11:20:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.124 uVs 11:20:40 I1Y Average and RMS of Measurements VT = -226.136 +- 7.212 uVs I1Y = -45.226 +- 1.443 uTm 11:20:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:20:45 Integrated Voltage Measurement... 11:20:54 Voltage Offset Correction: v_off_ini = 885.037 uV, v_off_fin = 887.637 uV 11:20:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.142 uVs 11:20:54 Integrated Voltage Measurement... 11:21:03 Voltage Offset Correction: v_off_ini = 896.970 uV, v_off_fin = 896.642 uV 11:21:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.129 uVs 11:21:03 Integrated Voltage Measurement... 11:21:12 Voltage Offset Correction: v_off_ini = 908.853 uV, v_off_fin = 886.703 uV 11:21:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.109 uVs 11:21:12 Integrated Voltage Measurement... 11:21:21 Voltage Offset Correction: v_off_ini = 885.933 uV, v_off_fin = 889.289 uV 11:21:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.983 uVs 11:21:21 Integrated Voltage Measurement... 11:21:30 Voltage Offset Correction: v_off_ini = 878.532 uV, v_off_fin = 882.450 uV 11:21:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.778 uVs 11:21:30 Integrated Voltage Measurement... 11:21:39 Voltage Offset Correction: v_off_ini = 876.012 uV, v_off_fin = 895.920 uV 11:21:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.700 uVs 11:21:42 I2X Average and RMS of Measurements VT = -73.140 +- 6.527 uVs I2X = 6.729 +- 0.600 uTm^2 11:21:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:21:47 Integrated Voltage Measurement... 11:21:56 Voltage Offset Correction: v_off_ini = 861.361 uV, v_off_fin = 855.510 uV 11:21:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.213 uVs 11:21:56 Integrated Voltage Measurement... 11:22:05 Voltage Offset Correction: v_off_ini = 859.700 uV, v_off_fin = 874.208 uV 11:22:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.123 uVs 11:22:05 Integrated Voltage Measurement... 11:22:14 Voltage Offset Correction: v_off_ini = 876.973 uV, v_off_fin = 873.783 uV 11:22:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.992 uVs 11:22:14 Integrated Voltage Measurement... 11:22:23 Voltage Offset Correction: v_off_ini = 878.571 uV, v_off_fin = 890.652 uV 11:22:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.780 uVs 11:22:23 Integrated Voltage Measurement... 11:22:32 Voltage Offset Correction: v_off_ini = 870.467 uV, v_off_fin = 867.967 uV 11:22:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.015 uVs 11:22:32 Integrated Voltage Measurement... 11:22:41 Voltage Offset Correction: v_off_ini = 874.302 uV, v_off_fin = 886.166 uV 11:22:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.756 uVs 11:22:43 I2Y Average and RMS of Measurements VT = -261.147 +- 2.646 uVs I2Y = -24.025 +- 0.243 uTm^2 11:22:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:23:02 Integrated Voltage Measurement... 11:23:11 Voltage Offset Correction: v_off_ini = 867.328 uV, v_off_fin = 869.785 uV 11:23:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.714 uVs 11:23:11 Integrated Voltage Measurement... 11:23:20 Voltage Offset Correction: v_off_ini = 873.189 uV, v_off_fin = 871.579 uV 11:23:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.530 uVs 11:23:20 Integrated Voltage Measurement... 11:23:29 Voltage Offset Correction: v_off_ini = 871.826 uV, v_off_fin = 858.404 uV 11:23:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.208 uVs 11:23:30 Integrated Voltage Measurement... 11:23:38 Voltage Offset Correction: v_off_ini = 867.200 uV, v_off_fin = 877.707 uV 11:23:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.940 uVs 11:23:39 Integrated Voltage Measurement... 11:23:47 Voltage Offset Correction: v_off_ini = 870.300 uV, v_off_fin = 853.966 uV 11:23:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.785 uVs 11:23:48 Integrated Voltage Measurement... 11:23:57 Voltage Offset Correction: v_off_ini = 870.478 uV, v_off_fin = 871.211 uV 11:23:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.299 uVs 11:24:01 I1X Average and RMS of Measurements VT = -88.413 +- 5.435 uVs I1X = 17.683 +- 1.087 uTm 11:24:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:24:08 Integrated Voltage Measurement... 11:24:17 Voltage Offset Correction: v_off_ini = 881.268 uV, v_off_fin = 870.984 uV 11:24:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.172 uVs 11:24:17 Integrated Voltage Measurement... 11:24:25 Voltage Offset Correction: v_off_ini = 899.145 uV, v_off_fin = 864.171 uV 11:24:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.903 uVs 11:24:26 Integrated Voltage Measurement... 11:24:35 Voltage Offset Correction: v_off_ini = 850.430 uV, v_off_fin = 838.748 uV 11:24:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.723 uVs 11:24:35 Integrated Voltage Measurement... 11:24:44 Voltage Offset Correction: v_off_ini = 864.608 uV, v_off_fin = 863.498 uV 11:24:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.369 uVs 11:24:44 Integrated Voltage Measurement... 11:24:53 Voltage Offset Correction: v_off_ini = 845.593 uV, v_off_fin = 860.535 uV 11:24:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.014 uVs 11:24:53 Integrated Voltage Measurement... 11:25:02 Voltage Offset Correction: v_off_ini = 862.843 uV, v_off_fin = 878.774 uV 11:25:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.197 uVs 11:25:06 I1Y Average and RMS of Measurements VT = -249.396 +- 5.080 uVs I1Y = -49.879 +- 1.016 uTm 11:25:11 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:25:14 Integrated Voltage Measurement... 11:25:23 Voltage Offset Correction: v_off_ini = 863.549 uV, v_off_fin = 875.428 uV 11:25:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -74.376 uVs 11:25:23 Integrated Voltage Measurement... 11:25:32 Voltage Offset Correction: v_off_ini = 870.661 uV, v_off_fin = 866.603 uV 11:25:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.049 uVs 11:25:32 Integrated Voltage Measurement... 11:25:41 Voltage Offset Correction: v_off_ini = 865.311 uV, v_off_fin = 855.803 uV 11:25:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.584 uVs 11:25:41 Integrated Voltage Measurement... 11:25:50 Voltage Offset Correction: v_off_ini = 860.940 uV, v_off_fin = 885.430 uV 11:25:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.549 uVs 11:25:50 Integrated Voltage Measurement... 11:25:59 Voltage Offset Correction: v_off_ini = 875.567 uV, v_off_fin = 866.730 uV 11:25:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.656 uVs 11:25:59 Integrated Voltage Measurement... 11:26:08 Voltage Offset Correction: v_off_ini = 914.239 uV, v_off_fin = 908.615 uV 11:26:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.201 uVs 11:26:10 I2X Average and RMS of Measurements VT = -103.902 +- 16.894 uVs I2X = 9.559 +- 1.554 uTm^2 11:26:15 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:26:18 Integrated Voltage Measurement... 11:26:27 Voltage Offset Correction: v_off_ini = 882.670 uV, v_off_fin = 848.751 uV 11:26:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.307 uVs 11:26:27 Integrated Voltage Measurement... 11:26:36 Voltage Offset Correction: v_off_ini = 846.280 uV, v_off_fin = 868.709 uV 11:26:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.580 uVs 11:26:36 Integrated Voltage Measurement... 11:26:45 Voltage Offset Correction: v_off_ini = 872.452 uV, v_off_fin = 870.714 uV 11:26:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.471 uVs 11:26:45 Integrated Voltage Measurement... 11:26:54 Voltage Offset Correction: v_off_ini = 885.211 uV, v_off_fin = 875.019 uV 11:26:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.648 uVs 11:26:54 Integrated Voltage Measurement... 11:27:03 Voltage Offset Correction: v_off_ini = 880.304 uV, v_off_fin = 892.291 uV 11:27:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.369 uVs 11:27:03 Integrated Voltage Measurement... 11:27:12 Voltage Offset Correction: v_off_ini = 886.050 uV, v_off_fin = 891.835 uV 11:27:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.683 uVs 11:27:15 I2Y Average and RMS of Measurements VT = -275.343 +- 10.392 uVs I2Y = -25.332 +- 0.956 uTm^2 11:27:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:27:24 Integrated Voltage Measurement... 11:27:33 Voltage Offset Correction: v_off_ini = 876.364 uV, v_off_fin = 881.056 uV 11:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.230 uVs 11:27:33 Integrated Voltage Measurement... 11:27:42 Voltage Offset Correction: v_off_ini = 890.051 uV, v_off_fin = 885.792 uV 11:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.159 uVs 11:27:42 Integrated Voltage Measurement... 11:27:51 Voltage Offset Correction: v_off_ini = 888.246 uV, v_off_fin = 884.725 uV 11:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.186 uVs 11:27:51 Integrated Voltage Measurement... 11:28:00 Voltage Offset Correction: v_off_ini = 886.305 uV, v_off_fin = 881.521 uV 11:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.919 uVs 11:28:00 Integrated Voltage Measurement... 11:28:09 Voltage Offset Correction: v_off_ini = 863.178 uV, v_off_fin = 871.992 uV 11:28:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.333 uVs 11:28:09 Integrated Voltage Measurement... 11:28:18 Voltage Offset Correction: v_off_ini = 873.023 uV, v_off_fin = 878.111 uV 11:28:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.981 uVs 11:28:22 I1X Average and RMS of Measurements VT = -83.968 +- 4.935 uVs I1X = 16.794 +- 0.987 uTm 11:28:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:28:29 Integrated Voltage Measurement... 11:28:38 Voltage Offset Correction: v_off_ini = 859.884 uV, v_off_fin = 864.679 uV 11:28:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.862 uVs 11:28:38 Integrated Voltage Measurement... 11:28:47 Voltage Offset Correction: v_off_ini = 867.506 uV, v_off_fin = 879.917 uV 11:28:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.831 uVs 11:28:47 Integrated Voltage Measurement... 11:28:56 Voltage Offset Correction: v_off_ini = 869.295 uV, v_off_fin = 869.163 uV 11:28:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.570 uVs 11:28:56 Integrated Voltage Measurement... 11:29:05 Voltage Offset Correction: v_off_ini = 867.727 uV, v_off_fin = 898.709 uV 11:29:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.544 uVs 11:29:05 Integrated Voltage Measurement... 11:29:14 Voltage Offset Correction: v_off_ini = 887.933 uV, v_off_fin = 877.901 uV 11:29:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.873 uVs 11:29:14 Integrated Voltage Measurement... 11:29:23 Voltage Offset Correction: v_off_ini = 883.578 uV, v_off_fin = 900.620 uV 11:29:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.956 uVs 11:29:27 I1Y Average and RMS of Measurements VT = -243.439 +- 5.031 uVs I1Y = -48.688 +- 1.006 uTm 11:29:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:29:35 Integrated Voltage Measurement... 11:29:44 Voltage Offset Correction: v_off_ini = 860.480 uV, v_off_fin = 863.339 uV 11:29:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.560 uVs 11:29:44 Integrated Voltage Measurement... 11:29:53 Voltage Offset Correction: v_off_ini = 859.114 uV, v_off_fin = 877.524 uV 11:29:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.485 uVs 11:29:53 Integrated Voltage Measurement... 11:30:02 Voltage Offset Correction: v_off_ini = 853.148 uV, v_off_fin = 844.946 uV 11:30:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.955 uVs 11:30:02 Integrated Voltage Measurement... 11:30:11 Voltage Offset Correction: v_off_ini = 835.048 uV, v_off_fin = 862.549 uV 11:30:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.689 uVs 11:30:11 Integrated Voltage Measurement... 11:30:20 Voltage Offset Correction: v_off_ini = 870.823 uV, v_off_fin = 850.407 uV 11:30:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.649 uVs 11:30:20 Integrated Voltage Measurement... 11:30:29 Voltage Offset Correction: v_off_ini = 852.003 uV, v_off_fin = 876.075 uV 11:30:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.382 uVs 11:30:31 I2X Average and RMS of Measurements VT = -95.787 +- 6.611 uVs I2X = 8.812 +- 0.608 uTm^2 11:30:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:30:39 Integrated Voltage Measurement... 11:30:48 Voltage Offset Correction: v_off_ini = 856.277 uV, v_off_fin = 835.506 uV 11:30:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.293 uVs 11:30:48 Integrated Voltage Measurement... 11:30:57 Voltage Offset Correction: v_off_ini = 846.110 uV, v_off_fin = 840.506 uV 11:30:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.354 uVs 11:30:57 Integrated Voltage Measurement... 11:31:06 Voltage Offset Correction: v_off_ini = 863.366 uV, v_off_fin = 860.388 uV 11:31:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.025 uVs 11:31:06 Integrated Voltage Measurement... 11:31:15 Voltage Offset Correction: v_off_ini = 854.357 uV, v_off_fin = 864.860 uV 11:31:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.539 uVs 11:31:15 Integrated Voltage Measurement... 11:31:24 Voltage Offset Correction: v_off_ini = 878.676 uV, v_off_fin = 846.884 uV 11:31:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.856 uVs 11:31:24 Integrated Voltage Measurement... 11:31:33 Voltage Offset Correction: v_off_ini = 863.351 uV, v_off_fin = 860.856 uV 11:31:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.407 uVs 11:31:36 I2Y Average and RMS of Measurements VT = -275.412 +- 12.312 uVs I2Y = -25.338 +- 1.133 uTm^2 11:31:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:45 Integrated Voltage Measurement... 11:31:54 Voltage Offset Correction: v_off_ini = 847.039 uV, v_off_fin = 845.498 uV 11:31:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.255 uVs 11:31:54 Integrated Voltage Measurement... 11:32:03 Voltage Offset Correction: v_off_ini = 825.558 uV, v_off_fin = 821.996 uV 11:32:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.924 uVs 11:32:03 Integrated Voltage Measurement... 11:32:12 Voltage Offset Correction: v_off_ini = 833.672 uV, v_off_fin = 835.989 uV 11:32:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.725 uVs 11:32:12 Integrated Voltage Measurement... 11:32:21 Voltage Offset Correction: v_off_ini = 851.191 uV, v_off_fin = 843.096 uV 11:32:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.502 uVs 11:32:21 Integrated Voltage Measurement... 11:32:30 Voltage Offset Correction: v_off_ini = 834.376 uV, v_off_fin = 846.709 uV 11:32:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.212 uVs 11:32:30 Integrated Voltage Measurement... 11:32:39 Voltage Offset Correction: v_off_ini = 853.529 uV, v_off_fin = 837.497 uV 11:32:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.814 uVs 11:32:43 I1X Average and RMS of Measurements VT = -81.072 +- 6.418 uVs I1X = 16.214 +- 1.284 uTm 11:32:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:32:50 Integrated Voltage Measurement... 11:32:59 Voltage Offset Correction: v_off_ini = 841.570 uV, v_off_fin = 833.952 uV 11:32:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.554 uVs 11:32:59 Integrated Voltage Measurement... 11:33:08 Voltage Offset Correction: v_off_ini = 837.900 uV, v_off_fin = 843.547 uV 11:33:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.225 uVs 11:33:08 Integrated Voltage Measurement... 11:33:17 Voltage Offset Correction: v_off_ini = 844.933 uV, v_off_fin = 826.955 uV 11:33:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.564 uVs 11:33:17 Integrated Voltage Measurement... 11:33:26 Voltage Offset Correction: v_off_ini = 862.476 uV, v_off_fin = 850.471 uV 11:33:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.094 uVs 11:33:26 Integrated Voltage Measurement... 11:33:35 Voltage Offset Correction: v_off_ini = 849.300 uV, v_off_fin = 838.658 uV 11:33:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.847 uVs 11:33:35 Integrated Voltage Measurement... 11:33:44 Voltage Offset Correction: v_off_ini = 849.986 uV, v_off_fin = 861.209 uV 11:33:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.087 uVs 11:33:48 I1Y Average and RMS of Measurements VT = -226.229 +- 2.149 uVs I1Y = -45.246 +- 0.430 uTm 11:33:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:33:56 Integrated Voltage Measurement... 11:34:05 Voltage Offset Correction: v_off_ini = 828.998 uV, v_off_fin = 841.108 uV 11:34:05 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -71.991 uVs 11:34:05 Integrated Voltage Measurement... 11:34:14 Voltage Offset Correction: v_off_ini = 849.820 uV, v_off_fin = 853.257 uV 11:34:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.555 uVs 11:34:14 Integrated Voltage Measurement... 11:34:23 Voltage Offset Correction: v_off_ini = 850.766 uV, v_off_fin = 851.627 uV 11:34:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.670 uVs 11:34:23 Integrated Voltage Measurement... 11:34:32 Voltage Offset Correction: v_off_ini = 838.526 uV, v_off_fin = 851.115 uV 11:34:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.261 uVs 11:34:32 Integrated Voltage Measurement... 11:34:41 Voltage Offset Correction: v_off_ini = 850.598 uV, v_off_fin = 825.737 uV 11:34:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.301 uVs 11:34:41 Integrated Voltage Measurement... 11:34:50 Voltage Offset Correction: v_off_ini = 847.325 uV, v_off_fin = 849.182 uV 11:34:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.861 uVs 11:34:52 I2X Average and RMS of Measurements VT = -81.940 +- 10.246 uVs I2X = 7.538 +- 0.943 uTm^2 11:34:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:35:00 Integrated Voltage Measurement... 11:35:09 Voltage Offset Correction: v_off_ini = 847.909 uV, v_off_fin = 853.448 uV 11:35:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.399 uVs 11:35:09 Integrated Voltage Measurement... 11:35:18 Voltage Offset Correction: v_off_ini = 850.894 uV, v_off_fin = 850.148 uV 11:35:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.271 uVs 11:35:18 Integrated Voltage Measurement... 11:35:27 Voltage Offset Correction: v_off_ini = 839.073 uV, v_off_fin = 842.937 uV 11:35:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.666 uVs 11:35:27 Integrated Voltage Measurement... 11:35:36 Voltage Offset Correction: v_off_ini = 832.233 uV, v_off_fin = 846.837 uV 11:35:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.306 uVs 11:35:36 Integrated Voltage Measurement... 11:35:45 Voltage Offset Correction: v_off_ini = 832.733 uV, v_off_fin = 827.983 uV 11:35:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.365 uVs 11:35:45 Integrated Voltage Measurement... 11:35:54 Voltage Offset Correction: v_off_ini = 833.363 uV, v_off_fin = 839.841 uV 11:35:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.918 uVs 11:35:57 I2Y Average and RMS of Measurements VT = -249.821 +- 4.847 uVs I2Y = -22.984 +- 0.446 uTm^2 11:36:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:36:06 Integrated Voltage Measurement... 11:36:15 Voltage Offset Correction: v_off_ini = 855.862 uV, v_off_fin = 845.539 uV 11:36:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -67.353 uVs 11:36:15 Integrated Voltage Measurement... 11:36:24 Voltage Offset Correction: v_off_ini = 853.422 uV, v_off_fin = 845.753 uV 11:36:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.741 uVs 11:36:24 Integrated Voltage Measurement... 11:36:33 Voltage Offset Correction: v_off_ini = 830.892 uV, v_off_fin = 836.956 uV 11:36:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.363 uVs 11:36:33 Integrated Voltage Measurement... 11:36:42 Voltage Offset Correction: v_off_ini = 848.452 uV, v_off_fin = 842.941 uV 11:36:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.472 uVs 11:36:42 Integrated Voltage Measurement... 11:36:51 Voltage Offset Correction: v_off_ini = 854.746 uV, v_off_fin = 828.049 uV 11:36:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.821 uVs 11:36:51 Integrated Voltage Measurement... 11:37:00 Voltage Offset Correction: v_off_ini = 840.516 uV, v_off_fin = 852.063 uV 11:37:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 75.602 uVs 11:37:04 I1X Average and RMS of Measurements VT = -76.392 +- 7.503 uVs I1X = 15.279 +- 1.500 uTm 11:37:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:37:11 Integrated Voltage Measurement... 11:37:19 Voltage Offset Correction: v_off_ini = 849.748 uV, v_off_fin = 836.089 uV 11:37:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -235.813 uVs 11:37:20 Integrated Voltage Measurement... 11:37:28 Voltage Offset Correction: v_off_ini = 848.040 uV, v_off_fin = 865.308 uV 11:37:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.395 uVs 11:37:29 Integrated Voltage Measurement... 11:37:37 Voltage Offset Correction: v_off_ini = 839.681 uV, v_off_fin = 837.154 uV 11:37:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.192 uVs 11:37:38 Integrated Voltage Measurement... 11:37:46 Voltage Offset Correction: v_off_ini = 821.753 uV, v_off_fin = 842.552 uV 11:37:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.417 uVs 11:37:47 Integrated Voltage Measurement... 11:37:55 Voltage Offset Correction: v_off_ini = 843.497 uV, v_off_fin = 840.457 uV 11:37:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.228 uVs 11:37:56 Integrated Voltage Measurement... 11:38:04 Voltage Offset Correction: v_off_ini = 847.169 uV, v_off_fin = 858.135 uV 11:38:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.097 uVs 11:38:09 I1Y Average and RMS of Measurements VT = -227.023 +- 4.550 uVs I1Y = -45.405 +- 0.911 uTm 11:38:14 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:38:16 Integrated Voltage Measurement... 11:38:25 Voltage Offset Correction: v_off_ini = 843.591 uV, v_off_fin = 847.726 uV 11:38:25 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -88.578 uVs 11:38:25 Integrated Voltage Measurement... 11:38:34 Voltage Offset Correction: v_off_ini = 841.882 uV, v_off_fin = 854.876 uV 11:38:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.376 uVs 11:38:34 Integrated Voltage Measurement... 11:38:43 Voltage Offset Correction: v_off_ini = 874.940 uV, v_off_fin = 856.530 uV 11:38:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.584 uVs 11:38:43 Integrated Voltage Measurement... 11:38:52 Voltage Offset Correction: v_off_ini = 862.967 uV, v_off_fin = 859.982 uV 11:38:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.905 uVs 11:38:52 Integrated Voltage Measurement... 11:39:01 Voltage Offset Correction: v_off_ini = 843.469 uV, v_off_fin = 842.581 uV 11:39:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.269 uVs 11:39:02 Integrated Voltage Measurement... 11:39:10 Voltage Offset Correction: v_off_ini = 845.561 uV, v_off_fin = 852.848 uV 11:39:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.105 uVs 11:39:13 I2X Average and RMS of Measurements VT = -76.803 +- 6.993 uVs I2X = 7.066 +- 0.643 uTm^2 11:39:18 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:39:21 Integrated Voltage Measurement... 11:39:30 Voltage Offset Correction: v_off_ini = 853.180 uV, v_off_fin = 857.063 uV 11:39:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.749 uVs 11:39:30 Integrated Voltage Measurement... 11:39:39 Voltage Offset Correction: v_off_ini = 848.799 uV, v_off_fin = 862.298 uV 11:39:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.256 uVs 11:39:39 Integrated Voltage Measurement... 11:39:48 Voltage Offset Correction: v_off_ini = 848.054 uV, v_off_fin = 858.486 uV 11:39:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.066 uVs 11:39:48 Integrated Voltage Measurement... 11:39:57 Voltage Offset Correction: v_off_ini = 852.479 uV, v_off_fin = 841.681 uV 11:39:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.383 uVs 11:39:57 Integrated Voltage Measurement... 11:40:06 Voltage Offset Correction: v_off_ini = 843.764 uV, v_off_fin = 869.565 uV 11:40:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.472 uVs 11:40:06 Integrated Voltage Measurement... 11:40:15 Voltage Offset Correction: v_off_ini = 875.498 uV, v_off_fin = 866.105 uV 11:40:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.314 uVs 11:40:17 I2Y Average and RMS of Measurements VT = -237.207 +- 1.423 uVs I2Y = -21.823 +- 0.131 uTm^2 11:40:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:40:26 Integrated Voltage Measurement... 11:40:35 Voltage Offset Correction: v_off_ini = 850.321 uV, v_off_fin = 847.404 uV 11:40:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.495 uVs 11:40:35 Integrated Voltage Measurement... 11:40:44 Voltage Offset Correction: v_off_ini = 845.858 uV, v_off_fin = 852.044 uV 11:40:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.520 uVs 11:40:44 Integrated Voltage Measurement... 11:40:53 Voltage Offset Correction: v_off_ini = 864.317 uV, v_off_fin = 848.191 uV 11:40:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.522 uVs 11:40:53 Integrated Voltage Measurement... 11:41:02 Voltage Offset Correction: v_off_ini = 853.748 uV, v_off_fin = 864.913 uV 11:41:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.433 uVs 11:41:02 Integrated Voltage Measurement... 11:41:11 Voltage Offset Correction: v_off_ini = 847.094 uV, v_off_fin = 856.019 uV 11:41:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.482 uVs 11:41:11 Integrated Voltage Measurement... 11:41:20 Voltage Offset Correction: v_off_ini = 865.961 uV, v_off_fin = 867.991 uV 11:41:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.183 uVs 11:41:24 I1X Average and RMS of Measurements VT = -78.273 +- 4.625 uVs I1X = 15.655 +- 0.925 uTm 11:41:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:41:31 Integrated Voltage Measurement... 11:41:40 Voltage Offset Correction: v_off_ini = 865.253 uV, v_off_fin = 845.637 uV 11:41:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.415 uVs 11:41:40 Integrated Voltage Measurement... 11:41:49 Voltage Offset Correction: v_off_ini = 865.828 uV, v_off_fin = 856.142 uV 11:41:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.408 uVs 11:41:49 Integrated Voltage Measurement... 11:41:58 Voltage Offset Correction: v_off_ini = 878.622 uV, v_off_fin = 863.171 uV 11:41:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.609 uVs 11:41:58 Integrated Voltage Measurement... 11:42:07 Voltage Offset Correction: v_off_ini = 857.316 uV, v_off_fin = 866.065 uV 11:42:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.693 uVs 11:42:07 Integrated Voltage Measurement... 11:42:16 Voltage Offset Correction: v_off_ini = 838.005 uV, v_off_fin = 844.652 uV 11:42:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.207 uVs 11:42:16 Integrated Voltage Measurement... 11:42:25 Voltage Offset Correction: v_off_ini = 861.617 uV, v_off_fin = 873.815 uV 11:42:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.619 uVs 11:42:29 I1Y Average and RMS of Measurements VT = -215.492 +- 7.974 uVs I1Y = -43.098 +- 1.595 uTm 11:42:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:42:37 Integrated Voltage Measurement... 11:42:46 Voltage Offset Correction: v_off_ini = 845.343 uV, v_off_fin = 855.878 uV 11:42:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -59.809 uVs 11:42:46 Integrated Voltage Measurement... 11:42:55 Voltage Offset Correction: v_off_ini = 862.458 uV, v_off_fin = 878.697 uV 11:42:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.146 uVs 11:42:55 Integrated Voltage Measurement... 11:43:04 Voltage Offset Correction: v_off_ini = 877.524 uV, v_off_fin = 873.740 uV 11:43:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.294 uVs 11:43:04 Integrated Voltage Measurement... 11:43:13 Voltage Offset Correction: v_off_ini = 861.329 uV, v_off_fin = 877.964 uV 11:43:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.724 uVs 11:43:13 Integrated Voltage Measurement... 11:43:22 Voltage Offset Correction: v_off_ini = 856.493 uV, v_off_fin = 860.700 uV 11:43:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.783 uVs 11:43:22 Integrated Voltage Measurement... 11:43:31 Voltage Offset Correction: v_off_ini = 875.707 uV, v_off_fin = 875.094 uV 11:43:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.595 uVs 11:43:33 I2X Average and RMS of Measurements VT = -78.725 +- 6.845 uVs I2X = 7.243 +- 0.630 uTm^2 11:43:39 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:43:41 Integrated Voltage Measurement... 11:43:50 Voltage Offset Correction: v_off_ini = 863.862 uV, v_off_fin = 869.647 uV 11:43:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.722 uVs 11:43:50 Integrated Voltage Measurement... 11:43:59 Voltage Offset Correction: v_off_ini = 849.789 uV, v_off_fin = 866.811 uV 11:43:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.980 uVs 11:43:59 Integrated Voltage Measurement... 11:44:08 Voltage Offset Correction: v_off_ini = 846.953 uV, v_off_fin = 851.561 uV 11:44:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.224 uVs 11:44:08 Integrated Voltage Measurement... 11:44:17 Voltage Offset Correction: v_off_ini = 851.399 uV, v_off_fin = 852.422 uV 11:44:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.991 uVs 11:44:17 Integrated Voltage Measurement... 11:44:26 Voltage Offset Correction: v_off_ini = 840.133 uV, v_off_fin = 824.250 uV 11:44:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.762 uVs 11:44:26 Integrated Voltage Measurement... 11:44:35 Voltage Offset Correction: v_off_ini = 843.330 uV, v_off_fin = 852.417 uV 11:44:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.494 uVs 11:44:38 I2Y Average and RMS of Measurements VT = -224.862 +- 4.882 uVs I2Y = -20.687 +- 0.449 uTm^2 11:44:45 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:44:50 Integrated Voltage Measurement... 11:44:59 Voltage Offset Correction: v_off_ini = 872.859 uV, v_off_fin = 856.417 uV 11:44:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.642 uVs 11:44:59 Integrated Voltage Measurement... 11:45:08 Voltage Offset Correction: v_off_ini = 840.916 uV, v_off_fin = 854.497 uV 11:45:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.064 uVs 11:45:08 Integrated Voltage Measurement... 11:45:17 Voltage Offset Correction: v_off_ini = 846.060 uV, v_off_fin = 851.128 uV 11:45:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.312 uVs 11:45:17 Integrated Voltage Measurement... 11:45:26 Voltage Offset Correction: v_off_ini = 848.772 uV, v_off_fin = 841.776 uV 11:45:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.517 uVs 11:45:26 Integrated Voltage Measurement... 11:45:35 Voltage Offset Correction: v_off_ini = 877.455 uV, v_off_fin = 879.932 uV 11:45:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.741 uVs 11:45:35 Integrated Voltage Measurement... 11:45:44 Voltage Offset Correction: v_off_ini = 870.464 uV, v_off_fin = 860.957 uV 11:45:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.711 uVs 11:45:48 I1X Average and RMS of Measurements VT = -75.498 +- 6.087 uVs I1X = 15.100 +- 1.217 uTm 11:45:50 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:45:55 Integrated Voltage Measurement... 11:46:04 Voltage Offset Correction: v_off_ini = 853.862 uV, v_off_fin = 851.491 uV 11:46:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.577 uVs 11:46:04 Integrated Voltage Measurement... 11:46:13 Voltage Offset Correction: v_off_ini = 863.127 uV, v_off_fin = 865.849 uV 11:46:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.813 uVs 11:46:13 Integrated Voltage Measurement... 11:46:22 Voltage Offset Correction: v_off_ini = 874.217 uV, v_off_fin = 852.146 uV 11:46:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.105 uVs 11:46:22 Integrated Voltage Measurement... 11:46:31 Voltage Offset Correction: v_off_ini = 854.612 uV, v_off_fin = 864.866 uV 11:46:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.824 uVs 11:46:31 Integrated Voltage Measurement... 11:46:40 Voltage Offset Correction: v_off_ini = 838.555 uV, v_off_fin = 827.504 uV 11:46:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.975 uVs 11:46:40 Integrated Voltage Measurement... 11:46:49 Voltage Offset Correction: v_off_ini = 850.925 uV, v_off_fin = 863.816 uV 11:46:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.752 uVs 11:46:53 I1Y Average and RMS of Measurements VT = -233.341 +- 5.108 uVs I1Y = -46.668 +- 1.022 uTm 11:46:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:46:58 Integrated Voltage Measurement... 11:47:07 Voltage Offset Correction: v_off_ini = 842.911 uV, v_off_fin = 831.653 uV 11:47:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -91.624 uVs 11:47:07 Integrated Voltage Measurement... 11:47:16 Voltage Offset Correction: v_off_ini = 851.411 uV, v_off_fin = 857.833 uV 11:47:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.160 uVs 11:47:16 Integrated Voltage Measurement... 11:47:25 Voltage Offset Correction: v_off_ini = 851.557 uV, v_off_fin = 842.714 uV 11:47:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.871 uVs 11:47:25 Integrated Voltage Measurement... 11:47:34 Voltage Offset Correction: v_off_ini = 840.351 uV, v_off_fin = 858.755 uV 11:47:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 53.252 uVs 11:47:34 Integrated Voltage Measurement... 11:47:43 Voltage Offset Correction: v_off_ini = 834.690 uV, v_off_fin = 833.731 uV 11:47:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.566 uVs 11:47:43 Integrated Voltage Measurement... 11:47:52 Voltage Offset Correction: v_off_ini = 845.878 uV, v_off_fin = 837.267 uV 11:47:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.566 uVs 11:47:54 I2X Average and RMS of Measurements VT = -69.007 +- 9.679 uVs I2X = 6.349 +- 0.891 uTm^2 11:47:57 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:48:00 Integrated Voltage Measurement... 11:48:09 Voltage Offset Correction: v_off_ini = 831.414 uV, v_off_fin = 824.660 uV 11:48:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.144 uVs 11:48:09 Integrated Voltage Measurement... 11:48:18 Voltage Offset Correction: v_off_ini = 831.049 uV, v_off_fin = 835.986 uV 11:48:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.516 uVs 11:48:18 Integrated Voltage Measurement... 11:48:27 Voltage Offset Correction: v_off_ini = 819.645 uV, v_off_fin = 845.645 uV 11:48:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.306 uVs 11:48:27 Integrated Voltage Measurement... 11:48:36 Voltage Offset Correction: v_off_ini = 842.845 uV, v_off_fin = 849.285 uV 11:48:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.295 uVs 11:48:36 Integrated Voltage Measurement... 11:48:45 Voltage Offset Correction: v_off_ini = 851.622 uV, v_off_fin = 849.670 uV 11:48:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.874 uVs 11:48:45 Integrated Voltage Measurement... 11:48:54 Voltage Offset Correction: v_off_ini = 851.378 uV, v_off_fin = 825.524 uV 11:48:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.220 uVs 11:48:56 I2Y Average and RMS of Measurements VT = -256.226 +- 11.775 uVs I2Y = -23.573 +- 1.083 uTm^2 11:49:00 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:49:05 Integrated Voltage Measurement... 11:49:14 Voltage Offset Correction: v_off_ini = 835.971 uV, v_off_fin = 840.665 uV 11:49:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.092 uVs 11:49:14 Integrated Voltage Measurement... 11:49:23 Voltage Offset Correction: v_off_ini = 830.715 uV, v_off_fin = 829.294 uV 11:49:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.132 uVs 11:49:23 Integrated Voltage Measurement... 11:49:32 Voltage Offset Correction: v_off_ini = 821.005 uV, v_off_fin = 823.805 uV 11:49:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.422 uVs 11:49:32 Integrated Voltage Measurement... 11:49:41 Voltage Offset Correction: v_off_ini = 851.030 uV, v_off_fin = 844.068 uV 11:49:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.407 uVs 11:49:41 Integrated Voltage Measurement... 11:49:50 Voltage Offset Correction: v_off_ini = 813.013 uV, v_off_fin = 823.770 uV 11:49:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.048 uVs 11:49:50 Integrated Voltage Measurement... 11:49:59 Voltage Offset Correction: v_off_ini = 822.129 uV, v_off_fin = 827.839 uV 11:49:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.123 uVs 11:50:03 I1X Average and RMS of Measurements VT = -74.704 +- 7.243 uVs I1X = 14.941 +- 1.449 uTm 11:50:05 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:50:10 Integrated Voltage Measurement... 11:50:19 Voltage Offset Correction: v_off_ini = 846.837 uV, v_off_fin = 841.160 uV 11:50:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.612 uVs 11:50:19 Integrated Voltage Measurement... 11:50:28 Voltage Offset Correction: v_off_ini = 834.845 uV, v_off_fin = 838.030 uV 11:50:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.132 uVs 11:50:28 Integrated Voltage Measurement... 11:50:37 Voltage Offset Correction: v_off_ini = 837.101 uV, v_off_fin = 814.751 uV 11:50:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.014 uVs 11:50:37 Integrated Voltage Measurement... 11:50:46 Voltage Offset Correction: v_off_ini = 842.022 uV, v_off_fin = 851.060 uV 11:50:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.340 uVs 11:50:46 Integrated Voltage Measurement... 11:50:55 Voltage Offset Correction: v_off_ini = 842.795 uV, v_off_fin = 824.531 uV 11:50:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.053 uVs 11:50:55 Integrated Voltage Measurement... 11:51:04 Voltage Offset Correction: v_off_ini = 847.391 uV, v_off_fin = 858.695 uV 11:51:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.777 uVs 11:51:08 I1Y Average and RMS of Measurements VT = -234.488 +- 13.701 uVs I1Y = -46.898 +- 2.740 uTm 11:51:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:51:13 Integrated Voltage Measurement... 11:51:22 Voltage Offset Correction: v_off_ini = 835.105 uV, v_off_fin = 851.651 uV 11:51:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.421 uVs 11:51:22 Integrated Voltage Measurement... 11:51:31 Voltage Offset Correction: v_off_ini = 837.993 uV, v_off_fin = 858.615 uV 11:51:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.006 uVs 11:51:31 Integrated Voltage Measurement... 11:51:40 Voltage Offset Correction: v_off_ini = 853.677 uV, v_off_fin = 830.590 uV 11:51:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.064 uVs 11:51:40 Integrated Voltage Measurement... 11:51:49 Voltage Offset Correction: v_off_ini = 842.745 uV, v_off_fin = 855.024 uV 11:51:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.693 uVs 11:51:49 Integrated Voltage Measurement... 11:51:58 Voltage Offset Correction: v_off_ini = 856.908 uV, v_off_fin = 828.911 uV 11:51:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.628 uVs 11:51:58 Integrated Voltage Measurement... 11:52:07 Voltage Offset Correction: v_off_ini = 853.278 uV, v_off_fin = 859.627 uV 11:52:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.906 uVs 11:52:10 I2X Average and RMS of Measurements VT = -69.953 +- 10.760 uVs I2X = 6.436 +- 0.990 uTm^2 11:52:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:52:15 Integrated Voltage Measurement... 11:52:24 Voltage Offset Correction: v_off_ini = 855.443 uV, v_off_fin = 858.823 uV 11:52:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.553 uVs 11:52:24 Integrated Voltage Measurement... 11:52:33 Voltage Offset Correction: v_off_ini = 857.505 uV, v_off_fin = 876.936 uV 11:52:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.750 uVs 11:52:33 Integrated Voltage Measurement... 11:52:42 Voltage Offset Correction: v_off_ini = 864.878 uV, v_off_fin = 877.730 uV 11:52:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.049 uVs 11:52:42 Integrated Voltage Measurement... 11:52:51 Voltage Offset Correction: v_off_ini = 864.311 uV, v_off_fin = 859.033 uV 11:52:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.911 uVs 11:52:51 Integrated Voltage Measurement... 11:53:00 Voltage Offset Correction: v_off_ini = 857.392 uV, v_off_fin = 872.492 uV 11:53:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.746 uVs 11:53:00 Integrated Voltage Measurement... 11:53:09 Voltage Offset Correction: v_off_ini = 862.179 uV, v_off_fin = 867.622 uV 11:53:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.333 uVs 11:53:11 I2Y Average and RMS of Measurements VT = -255.557 +- 8.100 uVs I2Y = -23.511 +- 0.745 uTm^2 11:53:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:53:20 Integrated Voltage Measurement... 11:53:29 Voltage Offset Correction: v_off_ini = 892.937 uV, v_off_fin = 884.891 uV 11:53:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.131 uVs 11:53:29 Integrated Voltage Measurement... 11:53:38 Voltage Offset Correction: v_off_ini = 884.731 uV, v_off_fin = 888.116 uV 11:53:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.379 uVs 11:53:38 Integrated Voltage Measurement... 11:53:47 Voltage Offset Correction: v_off_ini = 869.299 uV, v_off_fin = 883.407 uV 11:53:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.290 uVs 11:53:47 Integrated Voltage Measurement... 11:53:56 Voltage Offset Correction: v_off_ini = 868.133 uV, v_off_fin = 845.887 uV 11:53:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.960 uVs 11:53:56 Integrated Voltage Measurement... 11:54:05 Voltage Offset Correction: v_off_ini = 852.120 uV, v_off_fin = 855.898 uV 11:54:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.235 uVs 11:54:05 Integrated Voltage Measurement... 11:54:14 Voltage Offset Correction: v_off_ini = 860.281 uV, v_off_fin = 854.284 uV 11:54:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.851 uVs 11:54:18 I1X Average and RMS of Measurements VT = -77.141 +- 6.305 uVs I1X = 15.428 +- 1.261 uTm 11:54:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:54:25 Integrated Voltage Measurement... 11:54:34 Voltage Offset Correction: v_off_ini = 857.800 uV, v_off_fin = 847.743 uV 11:54:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -227.594 uVs 11:54:34 Integrated Voltage Measurement... 11:54:43 Voltage Offset Correction: v_off_ini = 851.989 uV, v_off_fin = 863.540 uV 11:54:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.604 uVs 11:54:43 Integrated Voltage Measurement... 11:54:52 Voltage Offset Correction: v_off_ini = 846.106 uV, v_off_fin = 828.031 uV 11:54:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.858 uVs 11:54:52 Integrated Voltage Measurement... 11:55:01 Voltage Offset Correction: v_off_ini = 857.573 uV, v_off_fin = 870.090 uV 11:55:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.011 uVs 11:55:01 Integrated Voltage Measurement... 11:55:10 Voltage Offset Correction: v_off_ini = 854.423 uV, v_off_fin = 857.375 uV 11:55:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.177 uVs 11:55:10 Integrated Voltage Measurement... 11:55:19 Voltage Offset Correction: v_off_ini = 857.228 uV, v_off_fin = 866.644 uV 11:55:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.325 uVs 11:55:23 I1Y Average and RMS of Measurements VT = -225.761 +- 4.840 uVs I1Y = -45.153 +- 0.969 uTm 11:55:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:55:28 Integrated Voltage Measurement... 11:55:37 Voltage Offset Correction: v_off_ini = 845.282 uV, v_off_fin = 837.522 uV 11:55:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.937 uVs 11:55:37 Integrated Voltage Measurement... 11:55:46 Voltage Offset Correction: v_off_ini = 831.411 uV, v_off_fin = 830.930 uV 11:55:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.598 uVs 11:55:47 Integrated Voltage Measurement... 11:55:55 Voltage Offset Correction: v_off_ini = 822.840 uV, v_off_fin = 821.383 uV 11:55:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.339 uVs 11:55:56 Integrated Voltage Measurement... 11:56:05 Voltage Offset Correction: v_off_ini = 824.968 uV, v_off_fin = 844.605 uV 11:56:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.287 uVs 11:56:05 Integrated Voltage Measurement... 11:56:14 Voltage Offset Correction: v_off_ini = 827.864 uV, v_off_fin = 829.505 uV 11:56:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.554 uVs 11:56:14 Integrated Voltage Measurement... 11:56:23 Voltage Offset Correction: v_off_ini = 846.214 uV, v_off_fin = 833.124 uV 11:56:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.434 uVs 11:56:25 I2X Average and RMS of Measurements VT = -78.525 +- 3.080 uVs I2X = 7.224 +- 0.283 uTm^2 11:56:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:56:30 Integrated Voltage Measurement... 11:56:39 Voltage Offset Correction: v_off_ini = 826.629 uV, v_off_fin = 829.967 uV 11:56:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.021 uVs 11:56:39 Integrated Voltage Measurement... 11:56:48 Voltage Offset Correction: v_off_ini = 826.431 uV, v_off_fin = 818.231 uV 11:56:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 272.145 uVs 11:56:48 Integrated Voltage Measurement... 11:56:57 Voltage Offset Correction: v_off_ini = 809.528 uV, v_off_fin = 808.356 uV 11:56:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.225 uVs 11:56:57 Integrated Voltage Measurement... 11:57:06 Voltage Offset Correction: v_off_ini = 818.796 uV, v_off_fin = 798.351 uV 11:57:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.743 uVs 11:57:06 Integrated Voltage Measurement... 11:57:15 Voltage Offset Correction: v_off_ini = 845.574 uV, v_off_fin = 835.818 uV 11:57:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.166 uVs 11:57:15 Integrated Voltage Measurement... 11:57:24 Voltage Offset Correction: v_off_ini = 835.823 uV, v_off_fin = 849.521 uV 11:57:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.884 uVs 11:57:27 I2Y Average and RMS of Measurements VT = -259.197 +- 5.945 uVs I2Y = -23.847 +- 0.548 uTm^2 11:57:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:57:35 Integrated Voltage Measurement... 11:57:44 Voltage Offset Correction: v_off_ini = 816.642 uV, v_off_fin = 821.378 uV 11:57:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -63.534 uVs 11:57:44 Integrated Voltage Measurement... 11:57:53 Voltage Offset Correction: v_off_ini = 823.923 uV, v_off_fin = 835.775 uV 11:57:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.256 uVs 11:57:53 Integrated Voltage Measurement... 11:58:02 Voltage Offset Correction: v_off_ini = 839.098 uV, v_off_fin = 843.082 uV 11:58:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.092 uVs 11:58:02 Integrated Voltage Measurement... 11:58:11 Voltage Offset Correction: v_off_ini = 828.512 uV, v_off_fin = 822.858 uV 11:58:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.078 uVs 11:58:11 Integrated Voltage Measurement... 11:58:20 Voltage Offset Correction: v_off_ini = 834.329 uV, v_off_fin = 826.950 uV 11:58:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.135 uVs 11:58:20 Integrated Voltage Measurement... 11:58:29 Voltage Offset Correction: v_off_ini = 833.158 uV, v_off_fin = 825.260 uV 11:58:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.303 uVs 11:58:34 I1X Average and RMS of Measurements VT = -69.733 +- 9.611 uVs I1X = 13.947 +- 1.922 uTm 11:58:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:58:40 Integrated Voltage Measurement... 11:58:49 Voltage Offset Correction: v_off_ini = 817.882 uV, v_off_fin = 829.458 uV 11:58:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -239.458 uVs 11:58:49 Integrated Voltage Measurement... 11:58:58 Voltage Offset Correction: v_off_ini = 814.379 uV, v_off_fin = 833.592 uV 11:58:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 245.036 uVs 11:58:58 Integrated Voltage Measurement... 11:59:07 Voltage Offset Correction: v_off_ini = 833.656 uV, v_off_fin = 825.141 uV 11:59:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.168 uVs 11:59:07 Integrated Voltage Measurement... 11:59:16 Voltage Offset Correction: v_off_ini = 828.305 uV, v_off_fin = 833.953 uV 11:59:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.321 uVs 11:59:16 Integrated Voltage Measurement... 11:59:25 Voltage Offset Correction: v_off_ini = 807.901 uV, v_off_fin = 795.100 uV 11:59:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.845 uVs 11:59:25 Integrated Voltage Measurement... 11:59:34 Voltage Offset Correction: v_off_ini = 826.966 uV, v_off_fin = 826.100 uV 11:59:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.939 uVs 11:59:39 I1Y Average and RMS of Measurements VT = -232.461 +- 7.390 uVs I1Y = -46.491 +- 1.476 uTm 11:59:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:59:44 Integrated Voltage Measurement... 11:59:53 Voltage Offset Correction: v_off_ini = 822.469 uV, v_off_fin = 813.589 uV 11:59:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.238 uVs 11:59:53 Integrated Voltage Measurement... 12:00:02 Voltage Offset Correction: v_off_ini = 825.811 uV, v_off_fin = 822.940 uV 12:00:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.703 uVs 12:00:02 Integrated Voltage Measurement... 12:00:11 Voltage Offset Correction: v_off_ini = 827.688 uV, v_off_fin = 825.218 uV 12:00:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.586 uVs 12:00:11 Integrated Voltage Measurement... 12:00:20 Voltage Offset Correction: v_off_ini = 820.814 uV, v_off_fin = 833.337 uV 12:00:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.330 uVs 12:00:20 Integrated Voltage Measurement... 12:00:29 Voltage Offset Correction: v_off_ini = 818.916 uV, v_off_fin = 798.691 uV 12:00:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.263 uVs 12:00:29 Integrated Voltage Measurement... 12:00:38 Voltage Offset Correction: v_off_ini = 799.447 uV, v_off_fin = 805.742 uV 12:00:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.552 uVs 12:00:40 I2X Average and RMS of Measurements VT = -86.945 +- 1.484 uVs I2X = 7.999 +- 0.137 uTm^2 12:00:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:00:45 Integrated Voltage Measurement... 12:00:54 Voltage Offset Correction: v_off_ini = 801.390 uV, v_off_fin = 795.315 uV 12:00:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.250 uVs 12:00:55 Integrated Voltage Measurement... 12:01:04 Voltage Offset Correction: v_off_ini = 794.985 uV, v_off_fin = 811.430 uV 12:01:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.895 uVs 12:01:04 Integrated Voltage Measurement... 12:01:13 Voltage Offset Correction: v_off_ini = 797.574 uV, v_off_fin = 797.050 uV 12:01:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.180 uVs 12:01:13 Integrated Voltage Measurement... 12:01:22 Voltage Offset Correction: v_off_ini = 790.517 uV, v_off_fin = 794.659 uV 12:01:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.333 uVs 12:01:22 Integrated Voltage Measurement... 12:01:31 Voltage Offset Correction: v_off_ini = 809.749 uV, v_off_fin = 813.371 uV 12:01:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.683 uVs 12:01:31 Integrated Voltage Measurement... 12:01:40 Voltage Offset Correction: v_off_ini = 801.803 uV, v_off_fin = 813.559 uV 12:01:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.295 uVs 12:01:42 I2Y Average and RMS of Measurements VT = -250.106 +- 6.755 uVs I2Y = -23.010 +- 0.622 uTm^2 12:01:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:01:50 Integrated Voltage Measurement... 12:01:59 Voltage Offset Correction: v_off_ini = 813.799 uV, v_off_fin = 809.822 uV 12:01:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -72.212 uVs 12:02:00 Integrated Voltage Measurement... 12:02:08 Voltage Offset Correction: v_off_ini = 772.274 uV, v_off_fin = 785.949 uV 12:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.878 uVs 12:02:09 Integrated Voltage Measurement... 12:02:18 Voltage Offset Correction: v_off_ini = 812.317 uV, v_off_fin = 825.813 uV 12:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.451 uVs 12:02:18 Integrated Voltage Measurement... 12:02:27 Voltage Offset Correction: v_off_ini = 810.313 uV, v_off_fin = 808.206 uV 12:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.949 uVs 12:02:27 Integrated Voltage Measurement... 12:02:36 Voltage Offset Correction: v_off_ini = 819.149 uV, v_off_fin = 803.867 uV 12:02:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.472 uVs 12:02:36 Integrated Voltage Measurement... 12:02:45 Voltage Offset Correction: v_off_ini = 800.231 uV, v_off_fin = 810.679 uV 12:02:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.777 uVs 12:02:49 I1X Average and RMS of Measurements VT = -77.457 +- 5.326 uVs I1X = 15.492 +- 1.065 uTm 12:02:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:02:56 Integrated Voltage Measurement... 12:03:05 Voltage Offset Correction: v_off_ini = 798.561 uV, v_off_fin = 787.264 uV 12:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.735 uVs 12:03:05 Integrated Voltage Measurement... 12:03:14 Voltage Offset Correction: v_off_ini = 810.895 uV, v_off_fin = 823.088 uV 12:03:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.605 uVs 12:03:14 Integrated Voltage Measurement... 12:03:23 Voltage Offset Correction: v_off_ini = 820.060 uV, v_off_fin = 800.877 uV 12:03:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -229.461 uVs 12:03:23 Integrated Voltage Measurement... 12:03:32 Voltage Offset Correction: v_off_ini = 808.558 uV, v_off_fin = 818.705 uV 12:03:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 236.476 uVs 12:03:32 Integrated Voltage Measurement... 12:03:41 Voltage Offset Correction: v_off_ini = 820.210 uV, v_off_fin = 804.601 uV 12:03:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.311 uVs 12:03:41 Integrated Voltage Measurement... 12:03:50 Voltage Offset Correction: v_off_ini = 811.007 uV, v_off_fin = 835.229 uV 12:03:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 232.847 uVs 12:03:54 I1Y Average and RMS of Measurements VT = -224.572 +- 6.204 uVs I1Y = -44.911 +- 1.239 uTm 12:03:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:03:59 Integrated Voltage Measurement... 12:04:08 Voltage Offset Correction: v_off_ini = 828.957 uV, v_off_fin = 815.302 uV 12:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.993 uVs 12:04:08 Integrated Voltage Measurement... 12:04:17 Voltage Offset Correction: v_off_ini = 815.921 uV, v_off_fin = 830.235 uV 12:04:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.645 uVs 12:04:17 Integrated Voltage Measurement... 12:04:26 Voltage Offset Correction: v_off_ini = 831.178 uV, v_off_fin = 832.792 uV 12:04:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.758 uVs 12:04:26 Integrated Voltage Measurement... 12:04:35 Voltage Offset Correction: v_off_ini = 838.183 uV, v_off_fin = 844.319 uV 12:04:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.212 uVs 12:04:35 Integrated Voltage Measurement... 12:04:44 Voltage Offset Correction: v_off_ini = 811.509 uV, v_off_fin = 819.474 uV 12:04:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.532 uVs 12:04:44 Integrated Voltage Measurement... 12:04:53 Voltage Offset Correction: v_off_ini = 843.737 uV, v_off_fin = 837.013 uV 12:04:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.277 uVs 12:04:56 I2X Average and RMS of Measurements VT = -78.736 +- 6.773 uVs I2X = 7.244 +- 0.623 uTm^2 12:04:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:05:01 Integrated Voltage Measurement... 12:05:10 Voltage Offset Correction: v_off_ini = 865.201 uV, v_off_fin = 855.737 uV 12:05:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.685 uVs 12:05:10 Integrated Voltage Measurement... 12:05:19 Voltage Offset Correction: v_off_ini = 858.142 uV, v_off_fin = 864.756 uV 12:05:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.108 uVs 12:05:19 Integrated Voltage Measurement... 12:05:28 Voltage Offset Correction: v_off_ini = 854.839 uV, v_off_fin = 853.086 uV 12:05:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.214 uVs 12:05:28 Integrated Voltage Measurement... 12:05:37 Voltage Offset Correction: v_off_ini = 860.840 uV, v_off_fin = 872.277 uV 12:05:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.035 uVs 12:05:37 Integrated Voltage Measurement... 12:05:46 Voltage Offset Correction: v_off_ini = 866.773 uV, v_off_fin = 865.944 uV 12:05:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.402 uVs 12:05:46 Integrated Voltage Measurement... 12:05:55 Voltage Offset Correction: v_off_ini = 860.795 uV, v_off_fin = 868.758 uV 12:05:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.756 uVs 12:05:57 I2Y Average and RMS of Measurements VT = -247.367 +- 9.492 uVs I2Y = -22.758 +- 0.873 uTm^2 12:06:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:06:18 Integrated Voltage Measurement... 12:06:27 Voltage Offset Correction: v_off_ini = 862.942 uV, v_off_fin = 829.454 uV 12:06:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.775 uVs 12:06:27 Integrated Voltage Measurement... 12:06:36 Voltage Offset Correction: v_off_ini = 830.091 uV, v_off_fin = 843.854 uV 12:06:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.600 uVs 12:06:36 Integrated Voltage Measurement... 12:06:45 Voltage Offset Correction: v_off_ini = 839.888 uV, v_off_fin = 856.728 uV 12:06:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.556 uVs 12:06:45 Integrated Voltage Measurement... 12:06:54 Voltage Offset Correction: v_off_ini = 875.218 uV, v_off_fin = 877.032 uV 12:06:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.846 uVs 12:06:54 Integrated Voltage Measurement... 12:07:03 Voltage Offset Correction: v_off_ini = 866.786 uV, v_off_fin = 868.840 uV 12:07:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.465 uVs 12:07:03 Integrated Voltage Measurement... 12:07:12 Voltage Offset Correction: v_off_ini = 853.075 uV, v_off_fin = 861.708 uV 12:07:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.157 uVs 12:07:16 I1X Average and RMS of Measurements VT = -103.733 +- 7.978 uVs I1X = 20.747 +- 1.595 uTm 12:07:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:07:23 Integrated Voltage Measurement... 12:07:32 Voltage Offset Correction: v_off_ini = 857.334 uV, v_off_fin = 853.107 uV 12:07:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.291 uVs 12:07:32 Integrated Voltage Measurement... 12:07:41 Voltage Offset Correction: v_off_ini = 856.331 uV, v_off_fin = 853.761 uV 12:07:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.682 uVs 12:07:41 Integrated Voltage Measurement... 12:07:50 Voltage Offset Correction: v_off_ini = 847.466 uV, v_off_fin = 838.594 uV 12:07:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.632 uVs 12:07:50 Integrated Voltage Measurement... 12:07:59 Voltage Offset Correction: v_off_ini = 837.031 uV, v_off_fin = 848.570 uV 12:07:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.052 uVs 12:07:59 Integrated Voltage Measurement... 12:08:08 Voltage Offset Correction: v_off_ini = 843.459 uV, v_off_fin = 842.189 uV 12:08:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.880 uVs 12:08:08 Integrated Voltage Measurement... 12:08:17 Voltage Offset Correction: v_off_ini = 854.526 uV, v_off_fin = 840.880 uV 12:08:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.880 uVs 12:08:21 I1Y Average and RMS of Measurements VT = -244.070 +- 2.872 uVs I1Y = -48.814 +- 0.574 uTm 12:08:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:08:29 Integrated Voltage Measurement... 12:08:38 Voltage Offset Correction: v_off_ini = 807.119 uV, v_off_fin = 811.899 uV 12:08:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.296 uVs 12:08:38 Integrated Voltage Measurement... 12:08:47 Voltage Offset Correction: v_off_ini = 835.737 uV, v_off_fin = 838.006 uV 12:08:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.503 uVs 12:08:47 Integrated Voltage Measurement... 12:08:56 Voltage Offset Correction: v_off_ini = 842.958 uV, v_off_fin = 832.800 uV 12:08:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.274 uVs 12:08:56 Integrated Voltage Measurement... 12:09:05 Voltage Offset Correction: v_off_ini = 854.052 uV, v_off_fin = 850.163 uV 12:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.159 uVs 12:09:05 Integrated Voltage Measurement... 12:09:14 Voltage Offset Correction: v_off_ini = 826.589 uV, v_off_fin = 798.969 uV 12:09:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.429 uVs 12:09:14 Integrated Voltage Measurement... 12:09:23 Voltage Offset Correction: v_off_ini = 819.233 uV, v_off_fin = 844.192 uV 12:09:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.511 uVs 12:09:25 I2X Average and RMS of Measurements VT = -105.862 +- 6.916 uVs I2X = 9.739 +- 0.636 uTm^2 12:09:30 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:09:33 Integrated Voltage Measurement... 12:09:42 Voltage Offset Correction: v_off_ini = 825.791 uV, v_off_fin = 819.984 uV 12:09:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.286 uVs 12:09:42 Integrated Voltage Measurement... 12:09:51 Voltage Offset Correction: v_off_ini = 811.405 uV, v_off_fin = 804.285 uV 12:09:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.317 uVs 12:09:51 Integrated Voltage Measurement... 12:10:00 Voltage Offset Correction: v_off_ini = 796.784 uV, v_off_fin = 812.140 uV 12:10:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.919 uVs 12:10:00 Integrated Voltage Measurement... 12:10:09 Voltage Offset Correction: v_off_ini = 815.060 uV, v_off_fin = 817.628 uV 12:10:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.520 uVs 12:10:09 Integrated Voltage Measurement... 12:10:18 Voltage Offset Correction: v_off_ini = 811.359 uV, v_off_fin = 807.828 uV 12:10:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.388 uVs 12:10:18 Integrated Voltage Measurement... 12:10:27 Voltage Offset Correction: v_off_ini = 817.775 uV, v_off_fin = 822.081 uV 12:10:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.578 uVs 12:10:30 I2Y Average and RMS of Measurements VT = -272.335 +- 5.823 uVs I2Y = -25.055 +- 0.536 uTm^2 12:10:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:10:39 Integrated Voltage Measurement... 12:10:48 Voltage Offset Correction: v_off_ini = 831.840 uV, v_off_fin = 825.795 uV 12:10:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -98.151 uVs 12:10:48 Integrated Voltage Measurement... 12:10:57 Voltage Offset Correction: v_off_ini = 826.527 uV, v_off_fin = 848.766 uV 12:10:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.806 uVs 12:10:57 Integrated Voltage Measurement... 12:11:06 Voltage Offset Correction: v_off_ini = 825.097 uV, v_off_fin = 822.026 uV 12:11:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.021 uVs 12:11:06 Integrated Voltage Measurement... 12:11:15 Voltage Offset Correction: v_off_ini = 824.999 uV, v_off_fin = 839.656 uV 12:11:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.816 uVs 12:11:15 Integrated Voltage Measurement... 12:11:24 Voltage Offset Correction: v_off_ini = 836.297 uV, v_off_fin = 839.797 uV 12:11:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.024 uVs 12:11:24 Integrated Voltage Measurement... 12:11:33 Voltage Offset Correction: v_off_ini = 836.874 uV, v_off_fin = 847.894 uV 12:11:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.916 uVs 12:11:37 I1X Average and RMS of Measurements VT = -91.289 +- 9.050 uVs I1X = 18.259 +- 1.810 uTm 12:11:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:11:44 Integrated Voltage Measurement... 12:11:53 Voltage Offset Correction: v_off_ini = 813.182 uV, v_off_fin = 822.452 uV 12:11:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.520 uVs 12:11:53 Integrated Voltage Measurement... 12:12:02 Voltage Offset Correction: v_off_ini = 823.944 uV, v_off_fin = 833.847 uV 12:12:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.827 uVs 12:12:02 Integrated Voltage Measurement... 12:12:11 Voltage Offset Correction: v_off_ini = 832.390 uV, v_off_fin = 818.437 uV 12:12:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.943 uVs 12:12:11 Integrated Voltage Measurement... 12:12:20 Voltage Offset Correction: v_off_ini = 829.149 uV, v_off_fin = 853.459 uV 12:12:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.387 uVs 12:12:20 Integrated Voltage Measurement... 12:12:29 Voltage Offset Correction: v_off_ini = 843.114 uV, v_off_fin = 848.615 uV 12:12:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.781 uVs 12:12:29 Integrated Voltage Measurement... 12:12:38 Voltage Offset Correction: v_off_ini = 871.085 uV, v_off_fin = 867.872 uV 12:12:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.451 uVs 12:12:42 I1Y Average and RMS of Measurements VT = -238.152 +- 6.369 uVs I1Y = -47.631 +- 1.274 uTm 12:12:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:12:50 Integrated Voltage Measurement... 12:12:59 Voltage Offset Correction: v_off_ini = 845.119 uV, v_off_fin = 851.279 uV 12:12:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.662 uVs 12:12:59 Integrated Voltage Measurement... 12:13:08 Voltage Offset Correction: v_off_ini = 836.156 uV, v_off_fin = 853.107 uV 12:13:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.778 uVs 12:13:08 Integrated Voltage Measurement... 12:13:17 Voltage Offset Correction: v_off_ini = 847.938 uV, v_off_fin = 838.786 uV 12:13:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.485 uVs 12:13:17 Integrated Voltage Measurement... 12:13:26 Voltage Offset Correction: v_off_ini = 837.353 uV, v_off_fin = 845.998 uV 12:13:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.247 uVs 12:13:26 Integrated Voltage Measurement... 12:13:35 Voltage Offset Correction: v_off_ini = 842.684 uV, v_off_fin = 841.692 uV 12:13:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.856 uVs 12:13:35 Integrated Voltage Measurement... 12:13:44 Voltage Offset Correction: v_off_ini = 839.372 uV, v_off_fin = 837.912 uV 12:13:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.941 uVs 12:13:47 I2X Average and RMS of Measurements VT = -105.661 +- 12.987 uVs I2X = 9.721 +- 1.195 uTm^2 12:13:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:13:54 Integrated Voltage Measurement... 12:14:03 Voltage Offset Correction: v_off_ini = 856.177 uV, v_off_fin = 860.708 uV 12:14:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.706 uVs 12:14:03 Integrated Voltage Measurement... 12:14:12 Voltage Offset Correction: v_off_ini = 861.089 uV, v_off_fin = 852.676 uV 12:14:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.791 uVs 12:14:12 Integrated Voltage Measurement... 12:14:21 Voltage Offset Correction: v_off_ini = 851.121 uV, v_off_fin = 848.250 uV 12:14:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.761 uVs 12:14:21 Integrated Voltage Measurement... 12:14:30 Voltage Offset Correction: v_off_ini = 834.244 uV, v_off_fin = 845.823 uV 12:14:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.350 uVs 12:14:30 Integrated Voltage Measurement... 12:14:39 Voltage Offset Correction: v_off_ini = 852.919 uV, v_off_fin = 855.068 uV 12:14:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.306 uVs 12:14:39 Integrated Voltage Measurement... 12:14:48 Voltage Offset Correction: v_off_ini = 862.490 uV, v_off_fin = 861.893 uV 12:14:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.090 uVs 12:14:51 I2Y Average and RMS of Measurements VT = -260.501 +- 7.180 uVs I2Y = -23.966 +- 0.661 uTm^2 12:14:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:15:00 Integrated Voltage Measurement... 12:15:09 Voltage Offset Correction: v_off_ini = 885.132 uV, v_off_fin = 864.241 uV 12:15:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.369 uVs 12:15:09 Integrated Voltage Measurement... 12:15:18 Voltage Offset Correction: v_off_ini = 870.043 uV, v_off_fin = 874.370 uV 12:15:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.178 uVs 12:15:18 Integrated Voltage Measurement... 12:15:27 Voltage Offset Correction: v_off_ini = 854.601 uV, v_off_fin = 862.481 uV 12:15:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.176 uVs 12:15:27 Integrated Voltage Measurement... 12:15:36 Voltage Offset Correction: v_off_ini = 844.447 uV, v_off_fin = 863.857 uV 12:15:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.354 uVs 12:15:36 Integrated Voltage Measurement... 12:15:45 Voltage Offset Correction: v_off_ini = 874.812 uV, v_off_fin = 866.331 uV 12:15:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.687 uVs 12:15:45 Integrated Voltage Measurement... 12:15:54 Voltage Offset Correction: v_off_ini = 872.002 uV, v_off_fin = 867.050 uV 12:15:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.836 uVs 12:15:58 I1X Average and RMS of Measurements VT = -83.933 +- 3.171 uVs I1X = 16.787 +- 0.634 uTm 12:16:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:16:05 Integrated Voltage Measurement... 12:16:14 Voltage Offset Correction: v_off_ini = 873.348 uV, v_off_fin = 847.481 uV 12:16:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -231.173 uVs 12:16:14 Integrated Voltage Measurement... 12:16:23 Voltage Offset Correction: v_off_ini = 839.945 uV, v_off_fin = 876.420 uV 12:16:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 229.966 uVs 12:16:23 Integrated Voltage Measurement... 12:16:32 Voltage Offset Correction: v_off_ini = 861.489 uV, v_off_fin = 844.475 uV 12:16:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.381 uVs 12:16:32 Integrated Voltage Measurement... 12:16:41 Voltage Offset Correction: v_off_ini = 858.742 uV, v_off_fin = 860.055 uV 12:16:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.587 uVs 12:16:41 Integrated Voltage Measurement... 12:16:50 Voltage Offset Correction: v_off_ini = 854.285 uV, v_off_fin = 826.308 uV 12:16:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.342 uVs 12:16:50 Integrated Voltage Measurement... 12:16:59 Voltage Offset Correction: v_off_ini = 831.519 uV, v_off_fin = 849.871 uV 12:16:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.238 uVs 12:17:03 I1Y Average and RMS of Measurements VT = -231.281 +- 0.577 uVs I1Y = -46.258 +- 0.114 uTm 12:17:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:17:11 Integrated Voltage Measurement... 12:17:20 Voltage Offset Correction: v_off_ini = 853.931 uV, v_off_fin = 853.949 uV 12:17:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.426 uVs 12:17:20 Integrated Voltage Measurement... 12:17:29 Voltage Offset Correction: v_off_ini = 853.637 uV, v_off_fin = 855.432 uV 12:17:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.595 uVs 12:17:29 Integrated Voltage Measurement... 12:17:38 Voltage Offset Correction: v_off_ini = 856.006 uV, v_off_fin = 833.424 uV 12:17:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.721 uVs 12:17:38 Integrated Voltage Measurement... 12:17:47 Voltage Offset Correction: v_off_ini = 840.069 uV, v_off_fin = 845.545 uV 12:17:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.261 uVs 12:17:47 Integrated Voltage Measurement... 12:17:56 Voltage Offset Correction: v_off_ini = 848.964 uV, v_off_fin = 841.349 uV 12:17:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.280 uVs 12:17:56 Integrated Voltage Measurement... 12:18:05 Voltage Offset Correction: v_off_ini = 871.748 uV, v_off_fin = 869.558 uV 12:18:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.008 uVs 12:18:08 I2X Average and RMS of Measurements VT = -98.882 +- 12.649 uVs I2X = 9.097 +- 1.164 uTm^2 12:18:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:18:15 Integrated Voltage Measurement... 12:18:24 Voltage Offset Correction: v_off_ini = 844.269 uV, v_off_fin = 828.176 uV 12:18:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.150 uVs 12:18:24 Integrated Voltage Measurement... 12:18:33 Voltage Offset Correction: v_off_ini = 842.365 uV, v_off_fin = 841.475 uV 12:18:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.375 uVs 12:18:33 Integrated Voltage Measurement... 12:18:42 Voltage Offset Correction: v_off_ini = 839.029 uV, v_off_fin = 838.620 uV 12:18:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.731 uVs 12:18:43 Integrated Voltage Measurement... 12:18:52 Voltage Offset Correction: v_off_ini = 833.052 uV, v_off_fin = 844.157 uV 12:18:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 257.974 uVs 12:18:52 Integrated Voltage Measurement... 12:19:01 Voltage Offset Correction: v_off_ini = 858.172 uV, v_off_fin = 836.868 uV 12:19:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.213 uVs 12:19:01 Integrated Voltage Measurement... 12:19:10 Voltage Offset Correction: v_off_ini = 844.618 uV, v_off_fin = 848.267 uV 12:19:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.416 uVs 12:19:12 I2Y Average and RMS of Measurements VT = -249.477 +- 4.376 uVs I2Y = -22.952 +- 0.402 uTm^2 12:19:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:19:21 Integrated Voltage Measurement... 12:19:30 Voltage Offset Correction: v_off_ini = 840.416 uV, v_off_fin = 832.679 uV 12:19:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.198 uVs 12:19:30 Integrated Voltage Measurement... 12:19:39 Voltage Offset Correction: v_off_ini = 832.741 uV, v_off_fin = 843.807 uV 12:19:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.577 uVs 12:19:39 Integrated Voltage Measurement... 12:19:48 Voltage Offset Correction: v_off_ini = 832.714 uV, v_off_fin = 834.958 uV 12:19:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.483 uVs 12:19:48 Integrated Voltage Measurement... 12:19:57 Voltage Offset Correction: v_off_ini = 814.365 uV, v_off_fin = 818.964 uV 12:19:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.864 uVs 12:19:57 Integrated Voltage Measurement... 12:20:06 Voltage Offset Correction: v_off_ini = 821.429 uV, v_off_fin = 810.089 uV 12:20:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.055 uVs 12:20:06 Integrated Voltage Measurement... 12:20:15 Voltage Offset Correction: v_off_ini = 817.964 uV, v_off_fin = 813.721 uV 12:20:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.904 uVs 12:20:19 I1X Average and RMS of Measurements VT = -91.347 +- 3.247 uVs I1X = 18.270 +- 0.650 uTm 12:20:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:20:26 Integrated Voltage Measurement... 12:20:35 Voltage Offset Correction: v_off_ini = 822.875 uV, v_off_fin = 831.720 uV 12:20:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.836 uVs 12:20:35 Integrated Voltage Measurement... 12:20:44 Voltage Offset Correction: v_off_ini = 805.294 uV, v_off_fin = 826.404 uV 12:20:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.186 uVs 12:20:44 Integrated Voltage Measurement... 12:20:53 Voltage Offset Correction: v_off_ini = 827.064 uV, v_off_fin = 801.742 uV 12:20:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.539 uVs 12:20:53 Integrated Voltage Measurement... 12:21:02 Voltage Offset Correction: v_off_ini = 815.877 uV, v_off_fin = 840.745 uV 12:21:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.541 uVs 12:21:02 Integrated Voltage Measurement... 12:21:11 Voltage Offset Correction: v_off_ini = 841.548 uV, v_off_fin = 828.672 uV 12:21:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.938 uVs 12:21:11 Integrated Voltage Measurement... 12:21:20 Voltage Offset Correction: v_off_ini = 850.144 uV, v_off_fin = 866.236 uV 12:21:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.416 uVs 12:21:24 I1Y Average and RMS of Measurements VT = -224.743 +- 3.113 uVs I1Y = -44.949 +- 0.623 uTm 12:21:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:21:32 Integrated Voltage Measurement... 12:21:41 Voltage Offset Correction: v_off_ini = 831.387 uV, v_off_fin = 817.336 uV 12:21:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.779 uVs 12:21:41 Integrated Voltage Measurement... 12:21:50 Voltage Offset Correction: v_off_ini = 837.989 uV, v_off_fin = 857.116 uV 12:21:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.520 uVs 12:21:50 Integrated Voltage Measurement... 12:21:59 Voltage Offset Correction: v_off_ini = 844.569 uV, v_off_fin = 837.058 uV 12:21:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.611 uVs 12:21:59 Integrated Voltage Measurement... 12:22:08 Voltage Offset Correction: v_off_ini = 831.250 uV, v_off_fin = 840.344 uV 12:22:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.945 uVs 12:22:08 Integrated Voltage Measurement... 12:22:17 Voltage Offset Correction: v_off_ini = 832.033 uV, v_off_fin = 824.836 uV 12:22:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.004 uVs 12:22:17 Integrated Voltage Measurement... 12:22:26 Voltage Offset Correction: v_off_ini = 851.992 uV, v_off_fin = 842.042 uV 12:22:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.712 uVs 12:22:29 I2X Average and RMS of Measurements VT = -84.095 +- 3.935 uVs I2X = 7.737 +- 0.362 uTm^2 12:22:34 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:22:36 Integrated Voltage Measurement... 12:22:45 Voltage Offset Correction: v_off_ini = 842.025 uV, v_off_fin = 839.969 uV 12:22:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.156 uVs 12:22:45 Integrated Voltage Measurement... 12:22:54 Voltage Offset Correction: v_off_ini = 846.135 uV, v_off_fin = 851.476 uV 12:22:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.489 uVs 12:22:54 Integrated Voltage Measurement... 12:23:03 Voltage Offset Correction: v_off_ini = 849.250 uV, v_off_fin = 862.839 uV 12:23:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.887 uVs 12:23:04 Integrated Voltage Measurement... 12:23:13 Voltage Offset Correction: v_off_ini = 866.142 uV, v_off_fin = 863.745 uV 12:23:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.506 uVs 12:23:13 Integrated Voltage Measurement... 12:23:22 Voltage Offset Correction: v_off_ini = 845.287 uV, v_off_fin = 852.719 uV 12:23:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.096 uVs 12:23:22 Integrated Voltage Measurement... 12:23:31 Voltage Offset Correction: v_off_ini = 839.705 uV, v_off_fin = 844.889 uV 12:23:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.348 uVs 12:23:33 I2Y Average and RMS of Measurements VT = -240.080 +- 6.194 uVs I2Y = -22.087 +- 0.570 uTm^2 12:23:38 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:23:42 Integrated Voltage Measurement... 12:23:51 Voltage Offset Correction: v_off_ini = 834.036 uV, v_off_fin = 828.417 uV 12:23:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -70.632 uVs 12:23:51 Integrated Voltage Measurement... 12:24:00 Voltage Offset Correction: v_off_ini = 812.719 uV, v_off_fin = 822.237 uV 12:24:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.505 uVs 12:24:00 Integrated Voltage Measurement... 12:24:09 Voltage Offset Correction: v_off_ini = 814.855 uV, v_off_fin = 818.439 uV 12:24:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.476 uVs 12:24:09 Integrated Voltage Measurement... 12:24:18 Voltage Offset Correction: v_off_ini = 834.029 uV, v_off_fin = 823.965 uV 12:24:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.732 uVs 12:24:18 Integrated Voltage Measurement... 12:24:27 Voltage Offset Correction: v_off_ini = 824.740 uV, v_off_fin = 843.256 uV 12:24:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.780 uVs 12:24:27 Integrated Voltage Measurement... 12:24:36 Voltage Offset Correction: v_off_ini = 837.987 uV, v_off_fin = 822.001 uV 12:24:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.479 uVs 12:24:40 I1X Average and RMS of Measurements VT = -89.601 +- 6.349 uVs I1X = 17.920 +- 1.270 uTm 12:24:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:24:47 Integrated Voltage Measurement... 12:24:56 Voltage Offset Correction: v_off_ini = 812.728 uV, v_off_fin = 801.957 uV 12:24:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.107 uVs 12:24:56 Integrated Voltage Measurement... 12:25:05 Voltage Offset Correction: v_off_ini = 817.381 uV, v_off_fin = 845.056 uV 12:25:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.026 uVs 12:25:05 Integrated Voltage Measurement... 12:25:14 Voltage Offset Correction: v_off_ini = 828.736 uV, v_off_fin = 816.706 uV 12:25:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.235 uVs 12:25:14 Integrated Voltage Measurement... 12:25:23 Voltage Offset Correction: v_off_ini = 838.982 uV, v_off_fin = 837.145 uV 12:25:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.815 uVs 12:25:23 Integrated Voltage Measurement... 12:25:32 Voltage Offset Correction: v_off_ini = 806.288 uV, v_off_fin = 811.538 uV 12:25:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.948 uVs 12:25:32 Integrated Voltage Measurement... 12:25:41 Voltage Offset Correction: v_off_ini = 805.349 uV, v_off_fin = 825.266 uV 12:25:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.073 uVs 12:25:45 I1Y Average and RMS of Measurements VT = -225.367 +- 3.033 uVs I1Y = -45.073 +- 0.607 uTm 12:25:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:25:53 Integrated Voltage Measurement... 12:26:02 Voltage Offset Correction: v_off_ini = 807.336 uV, v_off_fin = 819.240 uV 12:26:02 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -87.704 uVs 12:26:02 Integrated Voltage Measurement... 12:26:11 Voltage Offset Correction: v_off_ini = 804.775 uV, v_off_fin = 805.253 uV 12:26:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.059 uVs 12:26:11 Integrated Voltage Measurement... 12:26:20 Voltage Offset Correction: v_off_ini = 809.760 uV, v_off_fin = 801.979 uV 12:26:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.882 uVs 12:26:20 Integrated Voltage Measurement... 12:26:29 Voltage Offset Correction: v_off_ini = 783.932 uV, v_off_fin = 816.986 uV 12:26:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.736 uVs 12:26:29 Integrated Voltage Measurement... 12:26:38 Voltage Offset Correction: v_off_ini = 801.791 uV, v_off_fin = 790.566 uV 12:26:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -91.390 uVs 12:26:38 Integrated Voltage Measurement... 12:26:47 Voltage Offset Correction: v_off_ini = 783.855 uV, v_off_fin = 780.801 uV 12:26:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.935 uVs 12:26:50 I2X Average and RMS of Measurements VT = -88.451 +- 6.226 uVs I2X = 8.137 +- 0.572 uTm^2 12:26:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:26:57 Integrated Voltage Measurement... 12:27:06 Voltage Offset Correction: v_off_ini = 801.973 uV, v_off_fin = 805.843 uV 12:27:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.338 uVs 12:27:06 Integrated Voltage Measurement... 12:27:15 Voltage Offset Correction: v_off_ini = 803.158 uV, v_off_fin = 814.359 uV 12:27:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.320 uVs 12:27:15 Integrated Voltage Measurement... 12:27:24 Voltage Offset Correction: v_off_ini = 803.550 uV, v_off_fin = 810.431 uV 12:27:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.655 uVs 12:27:25 Integrated Voltage Measurement... 12:27:34 Voltage Offset Correction: v_off_ini = 817.946 uV, v_off_fin = 829.686 uV 12:27:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.698 uVs 12:27:34 Integrated Voltage Measurement... 12:27:43 Voltage Offset Correction: v_off_ini = 817.382 uV, v_off_fin = 817.848 uV 12:27:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.979 uVs 12:27:43 Integrated Voltage Measurement... 12:27:52 Voltage Offset Correction: v_off_ini = 809.346 uV, v_off_fin = 804.176 uV 12:27:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.016 uVs 12:27:54 I2Y Average and RMS of Measurements VT = -232.001 +- 7.440 uVs I2Y = -21.344 +- 0.685 uTm^2 12:28:02 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:28:06 Integrated Voltage Measurement... 12:28:15 Voltage Offset Correction: v_off_ini = 816.707 uV, v_off_fin = 816.378 uV 12:28:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.973 uVs 12:28:15 Integrated Voltage Measurement... 12:28:24 Voltage Offset Correction: v_off_ini = 821.753 uV, v_off_fin = 819.110 uV 12:28:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.964 uVs 12:28:24 Integrated Voltage Measurement... 12:28:33 Voltage Offset Correction: v_off_ini = 825.278 uV, v_off_fin = 820.288 uV 12:28:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.739 uVs 12:28:33 Integrated Voltage Measurement... 12:28:42 Voltage Offset Correction: v_off_ini = 825.776 uV, v_off_fin = 818.581 uV 12:28:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.266 uVs 12:28:42 Integrated Voltage Measurement... 12:28:51 Voltage Offset Correction: v_off_ini = 830.300 uV, v_off_fin = 828.683 uV 12:28:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.446 uVs 12:28:51 Integrated Voltage Measurement... 12:29:00 Voltage Offset Correction: v_off_ini = 832.718 uV, v_off_fin = 831.095 uV 12:29:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.206 uVs 12:29:04 I1X Average and RMS of Measurements VT = -77.599 +- 9.103 uVs I1X = 15.520 +- 1.821 uTm 12:29:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:29:11 Integrated Voltage Measurement... 12:29:20 Voltage Offset Correction: v_off_ini = 837.762 uV, v_off_fin = 818.259 uV 12:29:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.514 uVs 12:29:20 Integrated Voltage Measurement... 12:29:29 Voltage Offset Correction: v_off_ini = 820.729 uV, v_off_fin = 850.890 uV 12:29:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.765 uVs 12:29:29 Integrated Voltage Measurement... 12:29:38 Voltage Offset Correction: v_off_ini = 830.072 uV, v_off_fin = 814.141 uV 12:29:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.819 uVs 12:29:38 Integrated Voltage Measurement... 12:29:47 Voltage Offset Correction: v_off_ini = 828.030 uV, v_off_fin = 836.661 uV 12:29:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.203 uVs 12:29:47 Integrated Voltage Measurement... 12:29:56 Voltage Offset Correction: v_off_ini = 828.614 uV, v_off_fin = 818.481 uV 12:29:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.964 uVs 12:29:56 Integrated Voltage Measurement... 12:30:05 Voltage Offset Correction: v_off_ini = 831.610 uV, v_off_fin = 838.648 uV 12:30:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.800 uVs 12:30:09 I1Y Average and RMS of Measurements VT = -238.344 +- 1.392 uVs I1Y = -47.669 +- 0.278 uTm 12:30:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:30:15 Integrated Voltage Measurement... 12:30:24 Voltage Offset Correction: v_off_ini = 821.497 uV, v_off_fin = 830.569 uV 12:30:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.950 uVs 12:30:24 Integrated Voltage Measurement... 12:30:33 Voltage Offset Correction: v_off_ini = 837.117 uV, v_off_fin = 859.471 uV 12:30:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.653 uVs 12:30:33 Integrated Voltage Measurement... 12:30:42 Voltage Offset Correction: v_off_ini = 830.875 uV, v_off_fin = 831.936 uV 12:30:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.697 uVs 12:30:42 Integrated Voltage Measurement... 12:30:51 Voltage Offset Correction: v_off_ini = 821.967 uV, v_off_fin = 835.173 uV 12:30:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.137 uVs 12:30:51 Integrated Voltage Measurement... 12:31:00 Voltage Offset Correction: v_off_ini = 835.231 uV, v_off_fin = 821.384 uV 12:31:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.040 uVs 12:31:00 Integrated Voltage Measurement... 12:31:09 Voltage Offset Correction: v_off_ini = 823.174 uV, v_off_fin = 848.850 uV 12:31:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.810 uVs 12:31:11 I2X Average and RMS of Measurements VT = -86.381 +- 6.289 uVs I2X = 7.947 +- 0.579 uTm^2 12:31:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:31:16 Integrated Voltage Measurement... 12:31:25 Voltage Offset Correction: v_off_ini = 818.431 uV, v_off_fin = 810.141 uV 12:31:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.723 uVs 12:31:25 Integrated Voltage Measurement... 12:31:34 Voltage Offset Correction: v_off_ini = 814.480 uV, v_off_fin = 819.729 uV 12:31:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.122 uVs 12:31:34 Integrated Voltage Measurement... 12:31:43 Voltage Offset Correction: v_off_ini = 812.931 uV, v_off_fin = 805.567 uV 12:31:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.758 uVs 12:31:44 Integrated Voltage Measurement... 12:31:53 Voltage Offset Correction: v_off_ini = 808.506 uV, v_off_fin = 815.190 uV 12:31:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.253 uVs 12:31:53 Integrated Voltage Measurement... 12:32:02 Voltage Offset Correction: v_off_ini = 812.655 uV, v_off_fin = 812.700 uV 12:32:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.750 uVs 12:32:02 Integrated Voltage Measurement... 12:32:11 Voltage Offset Correction: v_off_ini = 816.211 uV, v_off_fin = 823.070 uV 12:32:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.591 uVs 12:32:13 I2Y Average and RMS of Measurements VT = -249.866 +- 11.052 uVs I2Y = -22.988 +- 1.017 uTm^2 12:32:17 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:32:21 Integrated Voltage Measurement... 12:32:30 Voltage Offset Correction: v_off_ini = 820.221 uV, v_off_fin = 829.485 uV 12:32:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -79.530 uVs 12:32:30 Integrated Voltage Measurement... 12:32:39 Voltage Offset Correction: v_off_ini = 804.091 uV, v_off_fin = 821.737 uV 12:32:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.461 uVs 12:32:39 Integrated Voltage Measurement... 12:32:48 Voltage Offset Correction: v_off_ini = 833.316 uV, v_off_fin = 828.467 uV 12:32:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.793 uVs 12:32:48 Integrated Voltage Measurement... 12:32:57 Voltage Offset Correction: v_off_ini = 830.973 uV, v_off_fin = 838.163 uV 12:32:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.242 uVs 12:32:57 Integrated Voltage Measurement... 12:33:06 Voltage Offset Correction: v_off_ini = 827.979 uV, v_off_fin = 826.663 uV 12:33:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.301 uVs 12:33:06 Integrated Voltage Measurement... 12:33:15 Voltage Offset Correction: v_off_ini = 837.529 uV, v_off_fin = 842.248 uV 12:33:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.133 uVs 12:33:20 I1X Average and RMS of Measurements VT = -89.410 +- 3.893 uVs I1X = 17.883 +- 0.778 uTm 12:33:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:33:26 Integrated Voltage Measurement... 12:33:35 Voltage Offset Correction: v_off_ini = 837.070 uV, v_off_fin = 823.475 uV 12:33:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.227 uVs 12:33:36 Integrated Voltage Measurement... 12:33:44 Voltage Offset Correction: v_off_ini = 837.466 uV, v_off_fin = 845.146 uV 12:33:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.100 uVs 12:33:45 Integrated Voltage Measurement... 12:33:53 Voltage Offset Correction: v_off_ini = 835.532 uV, v_off_fin = 826.717 uV 12:33:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.896 uVs 12:33:54 Integrated Voltage Measurement... 12:34:02 Voltage Offset Correction: v_off_ini = 852.156 uV, v_off_fin = 851.067 uV 12:34:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.957 uVs 12:34:03 Integrated Voltage Measurement... 12:34:11 Voltage Offset Correction: v_off_ini = 841.422 uV, v_off_fin = 838.095 uV 12:34:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.967 uVs 12:34:12 Integrated Voltage Measurement... 12:34:20 Voltage Offset Correction: v_off_ini = 847.896 uV, v_off_fin = 848.181 uV 12:34:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.044 uVs 12:34:25 I1Y Average and RMS of Measurements VT = -233.532 +- 7.062 uVs I1Y = -46.706 +- 1.412 uTm 12:34:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:34:30 Integrated Voltage Measurement... 12:34:39 Voltage Offset Correction: v_off_ini = 847.864 uV, v_off_fin = 843.468 uV 12:34:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.154 uVs 12:34:39 Integrated Voltage Measurement... 12:34:48 Voltage Offset Correction: v_off_ini = 846.627 uV, v_off_fin = 836.524 uV 12:34:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.052 uVs 12:34:48 Integrated Voltage Measurement... 12:34:57 Voltage Offset Correction: v_off_ini = 830.301 uV, v_off_fin = 835.291 uV 12:34:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.664 uVs 12:34:57 Integrated Voltage Measurement... 12:35:06 Voltage Offset Correction: v_off_ini = 843.742 uV, v_off_fin = 842.123 uV 12:35:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.021 uVs 12:35:06 Integrated Voltage Measurement... 12:35:15 Voltage Offset Correction: v_off_ini = 851.520 uV, v_off_fin = 834.700 uV 12:35:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.880 uVs 12:35:15 Integrated Voltage Measurement... 12:35:24 Voltage Offset Correction: v_off_ini = 847.427 uV, v_off_fin = 856.496 uV 12:35:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.401 uVs 12:35:27 I2X Average and RMS of Measurements VT = -86.695 +- 6.019 uVs I2X = 7.976 +- 0.554 uTm^2 12:35:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:35:32 Integrated Voltage Measurement... 12:35:41 Voltage Offset Correction: v_off_ini = 848.498 uV, v_off_fin = 867.467 uV 12:35:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.559 uVs 12:35:41 Integrated Voltage Measurement... 12:35:50 Voltage Offset Correction: v_off_ini = 846.977 uV, v_off_fin = 857.181 uV 12:35:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.378 uVs 12:35:50 Integrated Voltage Measurement... 12:35:59 Voltage Offset Correction: v_off_ini = 859.748 uV, v_off_fin = 857.185 uV 12:35:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.841 uVs 12:35:59 Integrated Voltage Measurement... 12:36:08 Voltage Offset Correction: v_off_ini = 866.782 uV, v_off_fin = 862.710 uV 12:36:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.226 uVs 12:36:08 Integrated Voltage Measurement... 12:36:17 Voltage Offset Correction: v_off_ini = 858.554 uV, v_off_fin = 873.384 uV 12:36:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.348 uVs 12:36:17 Integrated Voltage Measurement... 12:36:26 Voltage Offset Correction: v_off_ini = 863.912 uV, v_off_fin = 863.927 uV 12:36:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.613 uVs 12:36:28 I2Y Average and RMS of Measurements VT = -240.994 +- 5.989 uVs I2Y = -22.171 +- 0.551 uTm^2 12:36:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:36:37 Integrated Voltage Measurement... 12:36:45 Voltage Offset Correction: v_off_ini = 864.293 uV, v_off_fin = 873.548 uV 12:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.930 uVs 12:36:46 Integrated Voltage Measurement... 12:36:54 Voltage Offset Correction: v_off_ini = 848.274 uV, v_off_fin = 859.685 uV 12:36:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.686 uVs 12:36:55 Integrated Voltage Measurement... 12:37:03 Voltage Offset Correction: v_off_ini = 837.821 uV, v_off_fin = 851.535 uV 12:37:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.914 uVs 12:37:04 Integrated Voltage Measurement... 12:37:12 Voltage Offset Correction: v_off_ini = 865.555 uV, v_off_fin = 874.843 uV 12:37:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.966 uVs 12:37:13 Integrated Voltage Measurement... 12:37:22 Voltage Offset Correction: v_off_ini = 865.655 uV, v_off_fin = 871.461 uV 12:37:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.354 uVs 12:37:22 Integrated Voltage Measurement... 12:37:31 Voltage Offset Correction: v_off_ini = 879.073 uV, v_off_fin = 871.852 uV 12:37:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.041 uVs 12:37:35 I1X Average and RMS of Measurements VT = -88.815 +- 6.986 uVs I1X = 17.763 +- 1.398 uTm 12:37:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:37:42 Integrated Voltage Measurement... 12:37:50 Voltage Offset Correction: v_off_ini = 876.843 uV, v_off_fin = 851.525 uV 12:37:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.826 uVs 12:37:51 Integrated Voltage Measurement... 12:37:59 Voltage Offset Correction: v_off_ini = 867.829 uV, v_off_fin = 865.145 uV 12:37:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.779 uVs 12:38:00 Integrated Voltage Measurement... 12:38:08 Voltage Offset Correction: v_off_ini = 837.751 uV, v_off_fin = 844.019 uV 12:38:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.075 uVs 12:38:09 Integrated Voltage Measurement... 12:38:17 Voltage Offset Correction: v_off_ini = 874.473 uV, v_off_fin = 895.158 uV 12:38:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.200 uVs 12:38:18 Integrated Voltage Measurement... 12:38:26 Voltage Offset Correction: v_off_ini = 880.230 uV, v_off_fin = 861.600 uV 12:38:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.759 uVs 12:38:26 Integrated Voltage Measurement... 12:38:35 Voltage Offset Correction: v_off_ini = 862.417 uV, v_off_fin = 870.665 uV 12:38:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.704 uVs 12:38:40 I1Y Average and RMS of Measurements VT = -221.891 +- 2.631 uVs I1Y = -44.378 +- 0.526 uTm 12:38:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:38:45 Integrated Voltage Measurement... 12:38:54 Voltage Offset Correction: v_off_ini = 868.576 uV, v_off_fin = 859.018 uV 12:38:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.325 uVs 12:38:54 Integrated Voltage Measurement... 12:39:03 Voltage Offset Correction: v_off_ini = 864.417 uV, v_off_fin = 871.145 uV 12:39:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.299 uVs 12:39:03 Integrated Voltage Measurement... 12:39:12 Voltage Offset Correction: v_off_ini = 865.996 uV, v_off_fin = 848.877 uV 12:39:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.368 uVs 12:39:12 Integrated Voltage Measurement... 12:39:21 Voltage Offset Correction: v_off_ini = 870.911 uV, v_off_fin = 888.667 uV 12:39:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.333 uVs 12:39:21 Integrated Voltage Measurement... 12:39:30 Voltage Offset Correction: v_off_ini = 868.278 uV, v_off_fin = 872.208 uV 12:39:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.305 uVs 12:39:30 Integrated Voltage Measurement... 12:39:39 Voltage Offset Correction: v_off_ini = 902.239 uV, v_off_fin = 898.295 uV 12:39:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.505 uVs 12:39:41 I2X Average and RMS of Measurements VT = -92.356 +- 10.553 uVs I2X = 8.497 +- 0.971 uTm^2 12:39:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:39:46 Integrated Voltage Measurement... 12:39:55 Voltage Offset Correction: v_off_ini = 865.968 uV, v_off_fin = 873.217 uV 12:39:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.537 uVs 12:39:55 Integrated Voltage Measurement... 12:40:04 Voltage Offset Correction: v_off_ini = 850.260 uV, v_off_fin = 855.925 uV 12:40:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.969 uVs 12:40:04 Integrated Voltage Measurement... 12:40:13 Voltage Offset Correction: v_off_ini = 858.722 uV, v_off_fin = 857.595 uV 12:40:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.626 uVs 12:40:14 Integrated Voltage Measurement... 12:40:22 Voltage Offset Correction: v_off_ini = 843.099 uV, v_off_fin = 847.512 uV 12:40:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.870 uVs 12:40:23 Integrated Voltage Measurement... 12:40:32 Voltage Offset Correction: v_off_ini = 870.925 uV, v_off_fin = 876.386 uV 12:40:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.584 uVs 12:40:32 Integrated Voltage Measurement... 12:40:41 Voltage Offset Correction: v_off_ini = 885.171 uV, v_off_fin = 872.557 uV 12:40:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.000 uVs 12:40:43 I2Y Average and RMS of Measurements VT = -244.598 +- 3.116 uVs I2Y = -22.503 +- 0.287 uTm^2 12:40:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:40:51 Integrated Voltage Measurement... 12:41:00 Voltage Offset Correction: v_off_ini = 877.644 uV, v_off_fin = 877.807 uV 12:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.629 uVs 12:41:00 Integrated Voltage Measurement... 12:41:09 Voltage Offset Correction: v_off_ini = 871.164 uV, v_off_fin = 870.618 uV 12:41:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.669 uVs 12:41:09 Integrated Voltage Measurement... 12:41:18 Voltage Offset Correction: v_off_ini = 865.747 uV, v_off_fin = 853.725 uV 12:41:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.198 uVs 12:41:18 Integrated Voltage Measurement... 12:41:27 Voltage Offset Correction: v_off_ini = 846.895 uV, v_off_fin = 863.672 uV 12:41:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.934 uVs 12:41:27 Integrated Voltage Measurement... 12:41:36 Voltage Offset Correction: v_off_ini = 884.921 uV, v_off_fin = 877.732 uV 12:41:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.264 uVs 12:41:36 Integrated Voltage Measurement... 12:41:45 Voltage Offset Correction: v_off_ini = 866.179 uV, v_off_fin = 868.526 uV 12:41:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.769 uVs 12:41:50 I1X Average and RMS of Measurements VT = -87.744 +- 5.882 uVs I1X = 17.549 +- 1.177 uTm 12:41:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:41:56 Integrated Voltage Measurement... 12:42:05 Voltage Offset Correction: v_off_ini = 852.432 uV, v_off_fin = 827.316 uV 12:42:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -227.246 uVs 12:42:05 Integrated Voltage Measurement... 12:42:14 Voltage Offset Correction: v_off_ini = 860.397 uV, v_off_fin = 876.666 uV 12:42:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.964 uVs 12:42:14 Integrated Voltage Measurement... 12:42:23 Voltage Offset Correction: v_off_ini = 859.542 uV, v_off_fin = 863.071 uV 12:42:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.371 uVs 12:42:23 Integrated Voltage Measurement... 12:42:32 Voltage Offset Correction: v_off_ini = 858.555 uV, v_off_fin = 871.428 uV 12:42:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.793 uVs 12:42:32 Integrated Voltage Measurement... 12:42:41 Voltage Offset Correction: v_off_ini = 900.668 uV, v_off_fin = 896.230 uV 12:42:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.362 uVs 12:42:41 Integrated Voltage Measurement... 12:42:50 Voltage Offset Correction: v_off_ini = 873.248 uV, v_off_fin = 888.453 uV 12:42:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.064 uVs 12:42:54 I1Y Average and RMS of Measurements VT = -230.133 +- 3.294 uVs I1Y = -46.027 +- 0.659 uTm 12:42:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:43:00 Integrated Voltage Measurement... 12:43:09 Voltage Offset Correction: v_off_ini = 881.287 uV, v_off_fin = 885.256 uV 12:43:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.504 uVs 12:43:09 Integrated Voltage Measurement... 12:43:18 Voltage Offset Correction: v_off_ini = 881.775 uV, v_off_fin = 867.917 uV 12:43:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.702 uVs 12:43:18 Integrated Voltage Measurement... 12:43:27 Voltage Offset Correction: v_off_ini = 885.401 uV, v_off_fin = 881.101 uV 12:43:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.182 uVs 12:43:27 Integrated Voltage Measurement... 12:43:36 Voltage Offset Correction: v_off_ini = 887.954 uV, v_off_fin = 891.960 uV 12:43:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.381 uVs 12:43:36 Integrated Voltage Measurement... 12:43:45 Voltage Offset Correction: v_off_ini = 895.722 uV, v_off_fin = 883.395 uV 12:43:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.419 uVs 12:43:45 Integrated Voltage Measurement... 12:43:54 Voltage Offset Correction: v_off_ini = 878.535 uV, v_off_fin = 865.222 uV 12:43:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.700 uVs 12:43:56 I2X Average and RMS of Measurements VT = -94.981 +- 8.567 uVs I2X = 8.738 +- 0.788 uTm^2 12:43:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:44:01 Integrated Voltage Measurement... 12:44:10 Voltage Offset Correction: v_off_ini = 887.367 uV, v_off_fin = 890.634 uV 12:44:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.645 uVs 12:44:10 Integrated Voltage Measurement... 12:44:19 Voltage Offset Correction: v_off_ini = 883.415 uV, v_off_fin = 886.721 uV 12:44:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.900 uVs 12:44:19 Integrated Voltage Measurement... 12:44:28 Voltage Offset Correction: v_off_ini = 894.336 uV, v_off_fin = 899.330 uV 12:44:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.905 uVs 12:44:28 Integrated Voltage Measurement... 12:44:37 Voltage Offset Correction: v_off_ini = 900.373 uV, v_off_fin = 904.728 uV 12:44:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.740 uVs 12:44:37 Integrated Voltage Measurement... 12:44:46 Voltage Offset Correction: v_off_ini = 910.857 uV, v_off_fin = 904.808 uV 12:44:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.723 uVs 12:44:46 Integrated Voltage Measurement... 12:44:55 Voltage Offset Correction: v_off_ini = 896.937 uV, v_off_fin = 902.397 uV 12:44:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.276 uVs 12:44:58 I2Y Average and RMS of Measurements VT = -244.198 +- 4.841 uVs I2Y = -22.466 +- 0.445 uTm^2 12:45:02 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:45:06 Integrated Voltage Measurement... 12:45:15 Voltage Offset Correction: v_off_ini = 884.065 uV, v_off_fin = 886.017 uV 12:45:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -102.650 uVs 12:45:15 Integrated Voltage Measurement... 12:45:24 Voltage Offset Correction: v_off_ini = 892.567 uV, v_off_fin = 876.704 uV 12:45:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.320 uVs 12:45:24 Integrated Voltage Measurement... 12:45:33 Voltage Offset Correction: v_off_ini = 877.178 uV, v_off_fin = 898.943 uV 12:45:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.181 uVs 12:45:33 Integrated Voltage Measurement... 12:45:42 Voltage Offset Correction: v_off_ini = 908.620 uV, v_off_fin = 921.478 uV 12:45:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.491 uVs 12:45:42 Integrated Voltage Measurement... 12:45:51 Voltage Offset Correction: v_off_ini = 894.177 uV, v_off_fin = 904.715 uV 12:45:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.263 uVs 12:45:51 Integrated Voltage Measurement... 12:46:00 Voltage Offset Correction: v_off_ini = 883.968 uV, v_off_fin = 907.973 uV 12:46:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.895 uVs 12:46:04 I1X Average and RMS of Measurements VT = -98.967 +- 9.596 uVs I1X = 19.794 +- 1.919 uTm 12:46:07 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:46:11 Integrated Voltage Measurement... 12:46:20 Voltage Offset Correction: v_off_ini = 887.173 uV, v_off_fin = 880.307 uV 12:46:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.217 uVs 12:46:20 Integrated Voltage Measurement... 12:46:29 Voltage Offset Correction: v_off_ini = 897.550 uV, v_off_fin = 908.117 uV 12:46:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.855 uVs 12:46:29 Integrated Voltage Measurement... 12:46:38 Voltage Offset Correction: v_off_ini = 891.268 uV, v_off_fin = 870.217 uV 12:46:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.282 uVs 12:46:38 Integrated Voltage Measurement... 12:46:47 Voltage Offset Correction: v_off_ini = 905.302 uV, v_off_fin = 930.584 uV 12:46:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.042 uVs 12:46:47 Integrated Voltage Measurement... 12:46:56 Voltage Offset Correction: v_off_ini = 901.480 uV, v_off_fin = 883.214 uV 12:46:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.988 uVs 12:46:56 Integrated Voltage Measurement... 12:47:05 Voltage Offset Correction: v_off_ini = 883.323 uV, v_off_fin = 890.174 uV 12:47:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.106 uVs 12:47:09 I1Y Average and RMS of Measurements VT = -225.582 +- 5.470 uVs I1Y = -45.116 +- 1.093 uTm 12:47:12 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:47:14 Integrated Voltage Measurement... 12:47:23 Voltage Offset Correction: v_off_ini = 877.833 uV, v_off_fin = 888.967 uV 12:47:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.947 uVs 12:47:23 Integrated Voltage Measurement... 12:47:32 Voltage Offset Correction: v_off_ini = 889.830 uV, v_off_fin = 904.864 uV 12:47:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.887 uVs 12:47:33 Integrated Voltage Measurement... 12:47:42 Voltage Offset Correction: v_off_ini = 902.467 uV, v_off_fin = 897.782 uV 12:47:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.317 uVs 12:47:42 Integrated Voltage Measurement... 12:47:51 Voltage Offset Correction: v_off_ini = 886.258 uV, v_off_fin = 901.996 uV 12:47:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.676 uVs 12:47:51 Integrated Voltage Measurement... 12:48:00 Voltage Offset Correction: v_off_ini = 889.929 uV, v_off_fin = 882.974 uV 12:48:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.435 uVs 12:48:00 Integrated Voltage Measurement... 12:48:09 Voltage Offset Correction: v_off_ini = 894.660 uV, v_off_fin = 893.321 uV 12:48:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.898 uVs 12:48:11 I2X Average and RMS of Measurements VT = -91.360 +- 7.548 uVs I2X = 8.405 +- 0.694 uTm^2 12:48:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:48:16 Integrated Voltage Measurement... 12:48:25 Voltage Offset Correction: v_off_ini = 889.323 uV, v_off_fin = 866.252 uV 12:48:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -227.549 uVs 12:48:25 Integrated Voltage Measurement... 12:48:34 Voltage Offset Correction: v_off_ini = 884.658 uV, v_off_fin = 895.778 uV 12:48:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.898 uVs 12:48:34 Integrated Voltage Measurement... 12:48:43 Voltage Offset Correction: v_off_ini = 887.753 uV, v_off_fin = 880.270 uV 12:48:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.407 uVs 12:48:43 Integrated Voltage Measurement... 12:48:52 Voltage Offset Correction: v_off_ini = 898.246 uV, v_off_fin = 885.877 uV 12:48:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.792 uVs 12:48:52 Integrated Voltage Measurement... 12:49:01 Voltage Offset Correction: v_off_ini = 888.939 uV, v_off_fin = 892.769 uV 12:49:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.215 uVs 12:49:01 Integrated Voltage Measurement... 12:49:10 Voltage Offset Correction: v_off_ini = 888.176 uV, v_off_fin = 917.749 uV 12:49:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.197 uVs 12:49:13 I2Y Average and RMS of Measurements VT = -233.010 +- 3.875 uVs I2Y = -21.437 +- 0.356 uTm^2 12:49:29 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:49:33 Integrated Voltage Measurement... 12:49:42 Voltage Offset Correction: v_off_ini = 897.803 uV, v_off_fin = 888.938 uV 12:49:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -125.094 uVs 12:49:42 Integrated Voltage Measurement... 12:49:51 Voltage Offset Correction: v_off_ini = 877.934 uV, v_off_fin = 878.029 uV 12:49:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.464 uVs 12:49:51 Integrated Voltage Measurement... 12:50:00 Voltage Offset Correction: v_off_ini = 877.172 uV, v_off_fin = 876.090 uV 12:50:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.233 uVs 12:50:00 Integrated Voltage Measurement... 12:50:09 Voltage Offset Correction: v_off_ini = 889.919 uV, v_off_fin = 873.447 uV 12:50:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.249 uVs 12:50:09 Integrated Voltage Measurement... 12:50:18 Voltage Offset Correction: v_off_ini = 882.126 uV, v_off_fin = 869.347 uV 12:50:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.574 uVs 12:50:18 Integrated Voltage Measurement... 12:50:27 Voltage Offset Correction: v_off_ini = 877.525 uV, v_off_fin = 874.412 uV 12:50:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.374 uVs 12:50:31 I1X Average and RMS of Measurements VT = -116.498 +- 10.789 uVs I1X = 23.301 +- 2.159 uTm 12:50:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:50:38 Integrated Voltage Measurement... 12:50:47 Voltage Offset Correction: v_off_ini = 873.573 uV, v_off_fin = 858.987 uV 12:50:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.132 uVs 12:50:47 Integrated Voltage Measurement... 12:50:56 Voltage Offset Correction: v_off_ini = 855.230 uV, v_off_fin = 871.949 uV 12:50:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.772 uVs 12:50:56 Integrated Voltage Measurement... 12:51:05 Voltage Offset Correction: v_off_ini = 860.349 uV, v_off_fin = 846.251 uV 12:51:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.398 uVs 12:51:05 Integrated Voltage Measurement... 12:51:14 Voltage Offset Correction: v_off_ini = 872.492 uV, v_off_fin = 889.360 uV 12:51:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.755 uVs 12:51:14 Integrated Voltage Measurement... 12:51:23 Voltage Offset Correction: v_off_ini = 868.815 uV, v_off_fin = 866.607 uV 12:51:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.354 uVs 12:51:23 Integrated Voltage Measurement... 12:51:32 Voltage Offset Correction: v_off_ini = 866.928 uV, v_off_fin = 888.766 uV 12:51:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.185 uVs 12:51:36 I1Y Average and RMS of Measurements VT = -233.599 +- 5.330 uVs I1Y = -46.720 +- 1.066 uTm 12:51:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:51:44 Integrated Voltage Measurement... 12:51:53 Voltage Offset Correction: v_off_ini = 855.670 uV, v_off_fin = 862.347 uV 12:51:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.924 uVs 12:51:53 Integrated Voltage Measurement... 12:52:02 Voltage Offset Correction: v_off_ini = 867.570 uV, v_off_fin = 882.939 uV 12:52:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.873 uVs 12:52:02 Integrated Voltage Measurement... 12:52:11 Voltage Offset Correction: v_off_ini = 855.785 uV, v_off_fin = 857.861 uV 12:52:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.627 uVs 12:52:11 Integrated Voltage Measurement... 12:52:20 Voltage Offset Correction: v_off_ini = 856.585 uV, v_off_fin = 865.048 uV 12:52:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.295 uVs 12:52:20 Integrated Voltage Measurement... 12:52:29 Voltage Offset Correction: v_off_ini = 868.973 uV, v_off_fin = 855.216 uV 12:52:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.982 uVs 12:52:29 Integrated Voltage Measurement... 12:52:38 Voltage Offset Correction: v_off_ini = 879.276 uV, v_off_fin = 889.416 uV 12:52:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.583 uVs 12:52:40 I2X Average and RMS of Measurements VT = -123.381 +- 12.573 uVs I2X = 11.351 +- 1.157 uTm^2 12:52:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:52:48 Integrated Voltage Measurement... 12:52:57 Voltage Offset Correction: v_off_ini = 866.914 uV, v_off_fin = 869.143 uV 12:52:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.188 uVs 12:52:57 Integrated Voltage Measurement... 12:53:06 Voltage Offset Correction: v_off_ini = 850.987 uV, v_off_fin = 864.985 uV 12:53:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.901 uVs 12:53:06 Integrated Voltage Measurement... 12:53:15 Voltage Offset Correction: v_off_ini = 854.393 uV, v_off_fin = 870.101 uV 12:53:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.957 uVs 12:53:15 Integrated Voltage Measurement... 12:53:24 Voltage Offset Correction: v_off_ini = 872.946 uV, v_off_fin = 871.326 uV 12:53:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.237 uVs 12:53:24 Integrated Voltage Measurement... 12:53:33 Voltage Offset Correction: v_off_ini = 867.084 uV, v_off_fin = 878.992 uV 12:53:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.041 uVs 12:53:33 Integrated Voltage Measurement... 12:53:42 Voltage Offset Correction: v_off_ini = 879.323 uV, v_off_fin = 890.823 uV 12:53:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.995 uVs 12:53:45 I2Y Average and RMS of Measurements VT = -243.887 +- 3.102 uVs I2Y = -22.438 +- 0.285 uTm^2 12:53:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:53:54 Integrated Voltage Measurement... 12:54:03 Voltage Offset Correction: v_off_ini = 868.045 uV, v_off_fin = 877.005 uV 12:54:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.729 uVs 12:54:03 Integrated Voltage Measurement... 12:54:12 Voltage Offset Correction: v_off_ini = 878.972 uV, v_off_fin = 886.345 uV 12:54:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.984 uVs 12:54:12 Integrated Voltage Measurement... 12:54:21 Voltage Offset Correction: v_off_ini = 893.259 uV, v_off_fin = 900.028 uV 12:54:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.221 uVs 12:54:21 Integrated Voltage Measurement... 12:54:30 Voltage Offset Correction: v_off_ini = 908.981 uV, v_off_fin = 897.355 uV 12:54:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.699 uVs 12:54:30 Integrated Voltage Measurement... 12:54:39 Voltage Offset Correction: v_off_ini = 878.682 uV, v_off_fin = 901.828 uV 12:54:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.518 uVs 12:54:39 Integrated Voltage Measurement... 12:54:48 Voltage Offset Correction: v_off_ini = 878.770 uV, v_off_fin = 896.874 uV 12:54:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.814 uVs 12:54:52 I1X Average and RMS of Measurements VT = -112.328 +- 1.661 uVs I1X = 22.466 +- 0.332 uTm 12:54:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:54:59 Integrated Voltage Measurement... 12:55:08 Voltage Offset Correction: v_off_ini = 895.427 uV, v_off_fin = 879.330 uV 12:55:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.288 uVs 12:55:08 Integrated Voltage Measurement... 12:55:17 Voltage Offset Correction: v_off_ini = 897.137 uV, v_off_fin = 914.585 uV 12:55:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.706 uVs 12:55:17 Integrated Voltage Measurement... 12:55:26 Voltage Offset Correction: v_off_ini = 896.627 uV, v_off_fin = 878.037 uV 12:55:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.501 uVs 12:55:26 Integrated Voltage Measurement... 12:55:35 Voltage Offset Correction: v_off_ini = 892.232 uV, v_off_fin = 910.879 uV 12:55:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.892 uVs 12:55:35 Integrated Voltage Measurement... 12:55:44 Voltage Offset Correction: v_off_ini = 890.693 uV, v_off_fin = 876.873 uV 12:55:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.341 uVs 12:55:44 Integrated Voltage Measurement... 12:55:53 Voltage Offset Correction: v_off_ini = 905.779 uV, v_off_fin = 907.248 uV 12:55:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.181 uVs 12:55:57 I1Y Average and RMS of Measurements VT = -231.985 +- 12.834 uVs I1Y = -46.397 +- 2.567 uTm 12:56:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:56:05 Integrated Voltage Measurement... 12:56:14 Voltage Offset Correction: v_off_ini = 895.630 uV, v_off_fin = 884.686 uV 12:56:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -100.466 uVs 12:56:14 Integrated Voltage Measurement... 12:56:23 Voltage Offset Correction: v_off_ini = 874.560 uV, v_off_fin = 899.304 uV 12:56:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.986 uVs 12:56:23 Integrated Voltage Measurement... 12:56:32 Voltage Offset Correction: v_off_ini = 882.439 uV, v_off_fin = 877.362 uV 12:56:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.093 uVs 12:56:32 Integrated Voltage Measurement... 12:56:41 Voltage Offset Correction: v_off_ini = 878.346 uV, v_off_fin = 897.921 uV 12:56:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.138 uVs 12:56:41 Integrated Voltage Measurement... 12:56:50 Voltage Offset Correction: v_off_ini = 900.888 uV, v_off_fin = 897.492 uV 12:56:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.664 uVs 12:56:50 Integrated Voltage Measurement... 12:56:59 Voltage Offset Correction: v_off_ini = 896.227 uV, v_off_fin = 887.614 uV 12:56:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.874 uVs 12:57:02 I2X Average and RMS of Measurements VT = -115.703 +- 11.695 uVs I2X = 10.645 +- 1.076 uTm^2 12:57:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:57:09 Integrated Voltage Measurement... 12:57:18 Voltage Offset Correction: v_off_ini = 893.478 uV, v_off_fin = 903.815 uV 12:57:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.240 uVs 12:57:18 Integrated Voltage Measurement... 12:57:27 Voltage Offset Correction: v_off_ini = 930.159 uV, v_off_fin = 928.602 uV 12:57:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.444 uVs 12:57:27 Integrated Voltage Measurement... 12:57:36 Voltage Offset Correction: v_off_ini = 915.660 uV, v_off_fin = 901.264 uV 12:57:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.088 uVs 12:57:36 Integrated Voltage Measurement... 12:57:45 Voltage Offset Correction: v_off_ini = 888.245 uV, v_off_fin = 894.316 uV 12:57:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.632 uVs 12:57:45 Integrated Voltage Measurement... 12:57:54 Voltage Offset Correction: v_off_ini = 886.484 uV, v_off_fin = 884.018 uV 12:57:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -237.909 uVs 12:57:54 Integrated Voltage Measurement... 12:58:03 Voltage Offset Correction: v_off_ini = 870.357 uV, v_off_fin = 887.572 uV 12:58:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.709 uVs 12:58:06 I2Y Average and RMS of Measurements VT = -248.670 +- 10.670 uVs I2Y = -22.878 +- 0.982 uTm^2 12:58:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:58:15 Integrated Voltage Measurement... 12:58:24 Voltage Offset Correction: v_off_ini = 893.466 uV, v_off_fin = 882.617 uV 12:58:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.734 uVs 12:58:24 Integrated Voltage Measurement... 12:58:33 Voltage Offset Correction: v_off_ini = 870.906 uV, v_off_fin = 884.995 uV 12:58:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.326 uVs 12:58:33 Integrated Voltage Measurement... 12:58:42 Voltage Offset Correction: v_off_ini = 913.084 uV, v_off_fin = 916.886 uV 12:58:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.517 uVs 12:58:42 Integrated Voltage Measurement... 12:58:51 Voltage Offset Correction: v_off_ini = 884.354 uV, v_off_fin = 890.696 uV 12:58:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.284 uVs 12:58:51 Integrated Voltage Measurement... 12:59:00 Voltage Offset Correction: v_off_ini = 907.230 uV, v_off_fin = 907.960 uV 12:59:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.991 uVs 12:59:00 Integrated Voltage Measurement... 12:59:09 Voltage Offset Correction: v_off_ini = 907.866 uV, v_off_fin = 910.943 uV 12:59:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.644 uVs 12:59:13 I1X Average and RMS of Measurements VT = -115.749 +- 9.626 uVs I1X = 23.150 +- 1.925 uTm 12:59:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:59:20 Integrated Voltage Measurement... 12:59:29 Voltage Offset Correction: v_off_ini = 904.237 uV, v_off_fin = 890.083 uV 12:59:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.825 uVs 12:59:29 Integrated Voltage Measurement... 12:59:38 Voltage Offset Correction: v_off_ini = 910.976 uV, v_off_fin = 906.764 uV 12:59:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.400 uVs 12:59:38 Integrated Voltage Measurement... 12:59:47 Voltage Offset Correction: v_off_ini = 902.011 uV, v_off_fin = 901.291 uV 12:59:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.429 uVs 12:59:47 Integrated Voltage Measurement... 12:59:56 Voltage Offset Correction: v_off_ini = 927.776 uV, v_off_fin = 926.399 uV 12:59:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.844 uVs 12:59:56 Integrated Voltage Measurement... 13:00:05 Voltage Offset Correction: v_off_ini = 903.956 uV, v_off_fin = 911.484 uV 13:00:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.785 uVs 13:00:05 Integrated Voltage Measurement... 13:00:14 Voltage Offset Correction: v_off_ini = 918.115 uV, v_off_fin = 937.809 uV 13:00:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.107 uVs 13:00:18 I1Y Average and RMS of Measurements VT = -228.398 +- 2.864 uVs I1Y = -45.680 +- 0.573 uTm 13:00:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:00:26 Integrated Voltage Measurement... 13:00:35 Voltage Offset Correction: v_off_ini = 902.216 uV, v_off_fin = 903.806 uV 13:00:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.126 uVs 13:00:35 Integrated Voltage Measurement... 13:00:44 Voltage Offset Correction: v_off_ini = 916.033 uV, v_off_fin = 931.216 uV 13:00:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.826 uVs 13:00:44 Integrated Voltage Measurement... 13:00:53 Voltage Offset Correction: v_off_ini = 917.008 uV, v_off_fin = 926.382 uV 13:00:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.381 uVs 13:00:53 Integrated Voltage Measurement... 13:01:02 Voltage Offset Correction: v_off_ini = 936.070 uV, v_off_fin = 942.769 uV 13:01:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.373 uVs 13:01:02 Integrated Voltage Measurement... 13:01:11 Voltage Offset Correction: v_off_ini = 928.871 uV, v_off_fin = 933.848 uV 13:01:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.905 uVs 13:01:11 Integrated Voltage Measurement... 13:01:20 Voltage Offset Correction: v_off_ini = 913.014 uV, v_off_fin = 948.734 uV 13:01:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.066 uVs 13:01:23 I2X Average and RMS of Measurements VT = -103.280 +- 9.139 uVs I2X = 9.502 +- 0.841 uTm^2 13:01:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:01:30 Integrated Voltage Measurement... 13:01:39 Voltage Offset Correction: v_off_ini = 934.743 uV, v_off_fin = 940.321 uV 13:01:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.320 uVs 13:01:39 Integrated Voltage Measurement... 13:01:48 Voltage Offset Correction: v_off_ini = 947.697 uV, v_off_fin = 949.695 uV 13:01:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.616 uVs 13:01:48 Integrated Voltage Measurement... 13:01:57 Voltage Offset Correction: v_off_ini = 931.348 uV, v_off_fin = 926.762 uV 13:01:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.676 uVs 13:01:57 Integrated Voltage Measurement... 13:02:06 Voltage Offset Correction: v_off_ini = 941.377 uV, v_off_fin = 956.163 uV 13:02:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.460 uVs 13:02:06 Integrated Voltage Measurement... 13:02:15 Voltage Offset Correction: v_off_ini = 940.211 uV, v_off_fin = 936.817 uV 13:02:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -229.798 uVs 13:02:16 Integrated Voltage Measurement... 13:02:25 Voltage Offset Correction: v_off_ini = 927.866 uV, v_off_fin = 937.724 uV 13:02:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.405 uVs 13:02:27 I2Y Average and RMS of Measurements VT = -247.546 +- 10.954 uVs I2Y = -22.775 +- 1.008 uTm^2 13:02:32 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:02:36 Integrated Voltage Measurement... 13:02:45 Voltage Offset Correction: v_off_ini = 948.078 uV, v_off_fin = 934.289 uV 13:02:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.176 uVs 13:02:45 Integrated Voltage Measurement... 13:02:54 Voltage Offset Correction: v_off_ini = 941.134 uV, v_off_fin = 945.975 uV 13:02:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.539 uVs 13:02:54 Integrated Voltage Measurement... 13:03:03 Voltage Offset Correction: v_off_ini = 946.433 uV, v_off_fin = 946.009 uV 13:03:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.399 uVs 13:03:03 Integrated Voltage Measurement... 13:03:12 Voltage Offset Correction: v_off_ini = 950.942 uV, v_off_fin = 956.328 uV 13:03:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.761 uVs 13:03:12 Integrated Voltage Measurement... 13:03:21 Voltage Offset Correction: v_off_ini = 973.075 uV, v_off_fin = 956.524 uV 13:03:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.352 uVs 13:03:21 Integrated Voltage Measurement... 13:03:30 Voltage Offset Correction: v_off_ini = 966.711 uV, v_off_fin = 974.398 uV 13:03:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.019 uVs 13:03:34 I1X Average and RMS of Measurements VT = -113.708 +- 8.131 uVs I1X = 22.742 +- 1.626 uTm 13:03:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:03:41 Integrated Voltage Measurement... 13:03:50 Voltage Offset Correction: v_off_ini = 947.516 uV, v_off_fin = 952.590 uV 13:03:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -227.554 uVs 13:03:50 Integrated Voltage Measurement... 13:03:59 Voltage Offset Correction: v_off_ini = 954.959 uV, v_off_fin = 961.843 uV 13:03:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.583 uVs 13:03:59 Integrated Voltage Measurement... 13:04:08 Voltage Offset Correction: v_off_ini = 952.273 uV, v_off_fin = 935.775 uV 13:04:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.683 uVs 13:04:08 Integrated Voltage Measurement... 13:04:17 Voltage Offset Correction: v_off_ini = 929.936 uV, v_off_fin = 938.876 uV 13:04:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.954 uVs 13:04:17 Integrated Voltage Measurement... 13:04:26 Voltage Offset Correction: v_off_ini = 929.571 uV, v_off_fin = 930.372 uV 13:04:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.791 uVs 13:04:26 Integrated Voltage Measurement... 13:04:35 Voltage Offset Correction: v_off_ini = 918.968 uV, v_off_fin = 940.657 uV 13:04:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.212 uVs 13:04:39 I1Y Average and RMS of Measurements VT = -224.963 +- 5.332 uVs I1Y = -44.994 +- 1.065 uTm 13:04:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:04:47 Integrated Voltage Measurement... 13:04:56 Voltage Offset Correction: v_off_ini = 902.259 uV, v_off_fin = 913.290 uV 13:04:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.638 uVs 13:04:56 Integrated Voltage Measurement... 13:05:05 Voltage Offset Correction: v_off_ini = 923.921 uV, v_off_fin = 936.210 uV 13:05:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.926 uVs 13:05:05 Integrated Voltage Measurement... 13:05:14 Voltage Offset Correction: v_off_ini = 920.507 uV, v_off_fin = 904.279 uV 13:05:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.903 uVs 13:05:14 Integrated Voltage Measurement... 13:05:23 Voltage Offset Correction: v_off_ini = 911.073 uV, v_off_fin = 929.631 uV 13:05:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.163 uVs 13:05:23 Integrated Voltage Measurement... 13:05:32 Voltage Offset Correction: v_off_ini = 919.275 uV, v_off_fin = 916.154 uV 13:05:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.740 uVs 13:05:32 Integrated Voltage Measurement... 13:05:41 Voltage Offset Correction: v_off_ini = 911.645 uV, v_off_fin = 908.308 uV 13:05:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.779 uVs 13:05:44 I2X Average and RMS of Measurements VT = -107.192 +- 9.195 uVs I2X = 9.862 +- 0.846 uTm^2 13:05:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:05:51 Integrated Voltage Measurement... 13:06:00 Voltage Offset Correction: v_off_ini = 903.826 uV, v_off_fin = 907.675 uV 13:06:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.713 uVs 13:06:00 Integrated Voltage Measurement... 13:06:09 Voltage Offset Correction: v_off_ini = 908.126 uV, v_off_fin = 915.783 uV 13:06:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.210 uVs 13:06:09 Integrated Voltage Measurement... 13:06:18 Voltage Offset Correction: v_off_ini = 900.034 uV, v_off_fin = 887.523 uV 13:06:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.876 uVs 13:06:18 Integrated Voltage Measurement... 13:06:27 Voltage Offset Correction: v_off_ini = 894.169 uV, v_off_fin = 912.418 uV 13:06:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.901 uVs 13:06:28 Integrated Voltage Measurement... 13:06:37 Voltage Offset Correction: v_off_ini = 897.544 uV, v_off_fin = 896.015 uV 13:06:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.005 uVs 13:06:37 Integrated Voltage Measurement... 13:06:46 Voltage Offset Correction: v_off_ini = 891.891 uV, v_off_fin = 900.185 uV 13:06:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.172 uVs 13:06:48 I2Y Average and RMS of Measurements VT = -235.146 +- 6.808 uVs I2Y = -21.633 +- 0.626 uTm^2 13:06:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:06:57 Integrated Voltage Measurement... 13:07:06 Voltage Offset Correction: v_off_ini = 915.969 uV, v_off_fin = 913.578 uV 13:07:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -109.224 uVs 13:07:06 Integrated Voltage Measurement... 13:07:15 Voltage Offset Correction: v_off_ini = 930.205 uV, v_off_fin = 901.970 uV 13:07:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.189 uVs 13:07:15 Integrated Voltage Measurement... 13:07:24 Voltage Offset Correction: v_off_ini = 910.089 uV, v_off_fin = 904.434 uV 13:07:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.318 uVs 13:07:24 Integrated Voltage Measurement... 13:07:33 Voltage Offset Correction: v_off_ini = 913.633 uV, v_off_fin = 906.402 uV 13:07:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.698 uVs 13:07:33 Integrated Voltage Measurement... 13:07:42 Voltage Offset Correction: v_off_ini = 920.220 uV, v_off_fin = 924.391 uV 13:07:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.997 uVs 13:07:42 Integrated Voltage Measurement... 13:07:51 Voltage Offset Correction: v_off_ini = 901.920 uV, v_off_fin = 909.291 uV 13:07:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.642 uVs 13:07:55 I1X Average and RMS of Measurements VT = -108.178 +- 2.340 uVs I1X = 21.636 +- 0.468 uTm 13:07:58 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:08:02 Integrated Voltage Measurement... 13:08:11 Voltage Offset Correction: v_off_ini = 894.776 uV, v_off_fin = 903.109 uV 13:08:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.811 uVs 13:08:11 Integrated Voltage Measurement... 13:08:20 Voltage Offset Correction: v_off_ini = 906.184 uV, v_off_fin = 925.987 uV 13:08:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.895 uVs 13:08:20 Integrated Voltage Measurement... 13:08:29 Voltage Offset Correction: v_off_ini = 922.658 uV, v_off_fin = 913.734 uV 13:08:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.789 uVs 13:08:29 Integrated Voltage Measurement... 13:08:38 Voltage Offset Correction: v_off_ini = 928.460 uV, v_off_fin = 940.736 uV 13:08:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.362 uVs 13:08:38 Integrated Voltage Measurement... 13:08:47 Voltage Offset Correction: v_off_ini = 933.946 uV, v_off_fin = 907.625 uV 13:08:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.673 uVs 13:08:47 Integrated Voltage Measurement... 13:08:56 Voltage Offset Correction: v_off_ini = 919.603 uV, v_off_fin = 910.135 uV 13:08:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.038 uVs 13:09:00 I1Y Average and RMS of Measurements VT = -229.595 +- 4.519 uVs I1Y = -45.919 +- 0.904 uTm 13:09:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:09:08 Integrated Voltage Measurement... 13:09:17 Voltage Offset Correction: v_off_ini = 891.594 uV, v_off_fin = 888.523 uV 13:09:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.637 uVs 13:09:17 Integrated Voltage Measurement... 13:09:26 Voltage Offset Correction: v_off_ini = 908.735 uV, v_off_fin = 927.030 uV 13:09:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.971 uVs 13:09:26 Integrated Voltage Measurement... 13:09:35 Voltage Offset Correction: v_off_ini = 924.990 uV, v_off_fin = 918.928 uV 13:09:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.745 uVs 13:09:35 Integrated Voltage Measurement... 13:09:44 Voltage Offset Correction: v_off_ini = 904.395 uV, v_off_fin = 904.394 uV 13:09:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.624 uVs 13:09:44 Integrated Voltage Measurement... 13:09:53 Voltage Offset Correction: v_off_ini = 889.280 uV, v_off_fin = 894.288 uV 13:09:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.160 uVs 13:09:53 Integrated Voltage Measurement... 13:10:02 Voltage Offset Correction: v_off_ini = 923.688 uV, v_off_fin = 917.940 uV 13:10:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.542 uVs 13:10:05 I2X Average and RMS of Measurements VT = -99.613 +- 5.083 uVs I2X = 9.164 +- 0.468 uTm^2 13:10:10 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:10:12 Integrated Voltage Measurement... 13:10:21 Voltage Offset Correction: v_off_ini = 926.126 uV, v_off_fin = 906.497 uV 13:10:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.663 uVs 13:10:22 Integrated Voltage Measurement... 13:10:30 Voltage Offset Correction: v_off_ini = 916.114 uV, v_off_fin = 903.685 uV 13:10:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.091 uVs 13:10:31 Integrated Voltage Measurement... 13:10:40 Voltage Offset Correction: v_off_ini = 900.463 uV, v_off_fin = 895.255 uV 13:10:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.274 uVs 13:10:40 Integrated Voltage Measurement... 13:10:49 Voltage Offset Correction: v_off_ini = 890.982 uV, v_off_fin = 893.386 uV 13:10:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.898 uVs 13:10:49 Integrated Voltage Measurement... 13:10:58 Voltage Offset Correction: v_off_ini = 878.743 uV, v_off_fin = 886.609 uV 13:10:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.344 uVs 13:10:58 Integrated Voltage Measurement... 13:11:07 Voltage Offset Correction: v_off_ini = 913.624 uV, v_off_fin = 909.004 uV 13:11:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.319 uVs 13:11:09 I2Y Average and RMS of Measurements VT = -231.765 +- 1.923 uVs I2Y = -21.322 +- 0.177 uTm^2 13:11:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:11:21 Integrated Voltage Measurement... 13:11:30 Voltage Offset Correction: v_off_ini = 914.765 uV, v_off_fin = 911.155 uV 13:11:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.274 uVs 13:11:30 Integrated Voltage Measurement... 13:11:39 Voltage Offset Correction: v_off_ini = 919.597 uV, v_off_fin = 902.040 uV 13:11:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.403 uVs 13:11:39 Integrated Voltage Measurement... 13:11:48 Voltage Offset Correction: v_off_ini = 906.505 uV, v_off_fin = 899.106 uV 13:11:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.505 uVs 13:11:48 Integrated Voltage Measurement... 13:11:57 Voltage Offset Correction: v_off_ini = 888.154 uV, v_off_fin = 891.244 uV 13:11:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.690 uVs 13:11:57 Integrated Voltage Measurement... 13:12:06 Voltage Offset Correction: v_off_ini = 894.431 uV, v_off_fin = 908.104 uV 13:12:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.363 uVs 13:12:06 Integrated Voltage Measurement... 13:12:15 Voltage Offset Correction: v_off_ini = 890.731 uV, v_off_fin = 905.413 uV 13:12:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.155 uVs 13:12:19 I1X Average and RMS of Measurements VT = -100.399 +- 5.972 uVs I1X = 20.080 +- 1.194 uTm 13:12:22 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:12:26 Integrated Voltage Measurement... 13:12:35 Voltage Offset Correction: v_off_ini = 936.346 uV, v_off_fin = 927.220 uV 13:12:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.610 uVs 13:12:35 Integrated Voltage Measurement... 13:12:44 Voltage Offset Correction: v_off_ini = 935.897 uV, v_off_fin = 920.821 uV 13:12:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.375 uVs 13:12:44 Integrated Voltage Measurement... 13:12:53 Voltage Offset Correction: v_off_ini = 920.279 uV, v_off_fin = 923.770 uV 13:12:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.284 uVs 13:12:53 Integrated Voltage Measurement... 13:13:02 Voltage Offset Correction: v_off_ini = 934.145 uV, v_off_fin = 929.166 uV 13:13:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.386 uVs 13:13:02 Integrated Voltage Measurement... 13:13:11 Voltage Offset Correction: v_off_ini = 926.994 uV, v_off_fin = 935.352 uV 13:13:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.907 uVs 13:13:11 Integrated Voltage Measurement... 13:13:20 Voltage Offset Correction: v_off_ini = 921.893 uV, v_off_fin = 935.543 uV 13:13:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.615 uVs 13:13:25 I1Y Average and RMS of Measurements VT = -221.363 +- 1.163 uVs I1Y = -44.273 +- 0.233 uTm 13:13:27 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:13:30 Integrated Voltage Measurement... 13:13:39 Voltage Offset Correction: v_off_ini = 938.203 uV, v_off_fin = 936.140 uV 13:13:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.418 uVs 13:13:39 Integrated Voltage Measurement... 13:13:48 Voltage Offset Correction: v_off_ini = 925.329 uV, v_off_fin = 948.259 uV 13:13:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.542 uVs 13:13:48 Integrated Voltage Measurement... 13:13:57 Voltage Offset Correction: v_off_ini = 943.771 uV, v_off_fin = 939.192 uV 13:13:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.775 uVs 13:13:57 Integrated Voltage Measurement... 13:14:06 Voltage Offset Correction: v_off_ini = 915.150 uV, v_off_fin = 936.976 uV 13:14:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.036 uVs 13:14:06 Integrated Voltage Measurement... 13:14:15 Voltage Offset Correction: v_off_ini = 923.300 uV, v_off_fin = 919.229 uV 13:14:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.945 uVs 13:14:15 Integrated Voltage Measurement... 13:14:24 Voltage Offset Correction: v_off_ini = 915.673 uV, v_off_fin = 936.502 uV 13:14:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.279 uVs 13:14:26 I2X Average and RMS of Measurements VT = -113.166 +- 10.000 uVs I2X = 10.411 +- 0.920 uTm^2 13:14:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:14:31 Integrated Voltage Measurement... 13:14:40 Voltage Offset Correction: v_off_ini = 916.825 uV, v_off_fin = 923.666 uV 13:14:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.829 uVs 13:14:40 Integrated Voltage Measurement... 13:14:49 Voltage Offset Correction: v_off_ini = 922.633 uV, v_off_fin = 926.130 uV 13:14:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.410 uVs 13:14:50 Integrated Voltage Measurement... 13:14:58 Voltage Offset Correction: v_off_ini = 919.078 uV, v_off_fin = 909.820 uV 13:14:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.583 uVs 13:14:59 Integrated Voltage Measurement... 13:15:08 Voltage Offset Correction: v_off_ini = 906.527 uV, v_off_fin = 914.870 uV 13:15:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.277 uVs 13:15:08 Integrated Voltage Measurement... 13:15:17 Voltage Offset Correction: v_off_ini = 904.680 uV, v_off_fin = 924.329 uV 13:15:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.018 uVs 13:15:17 Integrated Voltage Measurement... 13:15:26 Voltage Offset Correction: v_off_ini = 934.860 uV, v_off_fin = 942.455 uV 13:15:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.321 uVs 13:15:28 I2Y Average and RMS of Measurements VT = -247.240 +- 10.602 uVs I2Y = -22.746 +- 0.975 uTm^2 13:15:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:15:36 Integrated Voltage Measurement... 13:15:45 Voltage Offset Correction: v_off_ini = 930.097 uV, v_off_fin = 938.060 uV 13:15:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -108.965 uVs 13:15:45 Integrated Voltage Measurement... 13:15:54 Voltage Offset Correction: v_off_ini = 927.202 uV, v_off_fin = 937.255 uV 13:15:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.195 uVs 13:15:54 Integrated Voltage Measurement... 13:16:03 Voltage Offset Correction: v_off_ini = 930.929 uV, v_off_fin = 936.160 uV 13:16:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.823 uVs 13:16:04 Integrated Voltage Measurement... 13:16:12 Voltage Offset Correction: v_off_ini = 937.241 uV, v_off_fin = 946.681 uV 13:16:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.472 uVs 13:16:13 Integrated Voltage Measurement... 13:16:22 Voltage Offset Correction: v_off_ini = 942.989 uV, v_off_fin = 931.172 uV 13:16:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.857 uVs 13:16:22 Integrated Voltage Measurement... 13:16:31 Voltage Offset Correction: v_off_ini = 938.973 uV, v_off_fin = 938.256 uV 13:16:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.000 uVs 13:16:35 I1X Average and RMS of Measurements VT = -110.552 +- 0.498 uVs I1X = 22.111 +- 0.100 uTm 13:16:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:16:42 Integrated Voltage Measurement... 13:16:51 Voltage Offset Correction: v_off_ini = 962.376 uV, v_off_fin = 947.336 uV 13:16:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.945 uVs 13:16:51 Integrated Voltage Measurement... 13:17:00 Voltage Offset Correction: v_off_ini = 957.869 uV, v_off_fin = 964.787 uV 13:17:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.440 uVs 13:17:00 Integrated Voltage Measurement... 13:17:09 Voltage Offset Correction: v_off_ini = 956.741 uV, v_off_fin = 934.192 uV 13:17:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.674 uVs 13:17:09 Integrated Voltage Measurement... 13:17:18 Voltage Offset Correction: v_off_ini = 930.947 uV, v_off_fin = 961.039 uV 13:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.326 uVs 13:17:18 Integrated Voltage Measurement... 13:17:27 Voltage Offset Correction: v_off_ini = 954.172 uV, v_off_fin = 943.784 uV 13:17:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.650 uVs 13:17:27 Integrated Voltage Measurement... 13:17:36 Voltage Offset Correction: v_off_ini = 928.311 uV, v_off_fin = 940.251 uV 13:17:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.129 uVs 13:17:40 I1Y Average and RMS of Measurements VT = -233.861 +- 2.863 uVs I1Y = -46.772 +- 0.573 uTm 13:17:42 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:17:45 Integrated Voltage Measurement... 13:17:54 Voltage Offset Correction: v_off_ini = 916.439 uV, v_off_fin = 910.664 uV 13:17:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.775 uVs 13:17:54 Integrated Voltage Measurement... 13:18:03 Voltage Offset Correction: v_off_ini = 934.341 uV, v_off_fin = 940.860 uV 13:18:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.413 uVs 13:18:03 Integrated Voltage Measurement... 13:18:12 Voltage Offset Correction: v_off_ini = 929.104 uV, v_off_fin = 932.096 uV 13:18:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.696 uVs 13:18:12 Integrated Voltage Measurement... 13:18:21 Voltage Offset Correction: v_off_ini = 937.569 uV, v_off_fin = 942.104 uV 13:18:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.284 uVs 13:18:21 Integrated Voltage Measurement... 13:18:30 Voltage Offset Correction: v_off_ini = 933.167 uV, v_off_fin = 896.861 uV 13:18:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.929 uVs 13:18:30 Integrated Voltage Measurement... 13:18:39 Voltage Offset Correction: v_off_ini = 925.705 uV, v_off_fin = 919.367 uV 13:18:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.399 uVs 13:18:42 I2X Average and RMS of Measurements VT = -117.083 +- 8.209 uVs I2X = 10.772 +- 0.755 uTm^2 13:18:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:18:47 Integrated Voltage Measurement... 13:18:56 Voltage Offset Correction: v_off_ini = 924.777 uV, v_off_fin = 927.486 uV 13:18:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.757 uVs 13:18:56 Integrated Voltage Measurement... 13:19:05 Voltage Offset Correction: v_off_ini = 936.119 uV, v_off_fin = 917.196 uV 13:19:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.628 uVs 13:19:05 Integrated Voltage Measurement... 13:19:14 Voltage Offset Correction: v_off_ini = 908.381 uV, v_off_fin = 915.723 uV 13:19:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.331 uVs 13:19:14 Integrated Voltage Measurement... 13:19:23 Voltage Offset Correction: v_off_ini = 925.627 uV, v_off_fin = 920.864 uV 13:19:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.639 uVs 13:19:23 Integrated Voltage Measurement... 13:19:32 Voltage Offset Correction: v_off_ini = 918.785 uV, v_off_fin = 911.790 uV 13:19:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.420 uVs 13:19:32 Integrated Voltage Measurement... 13:19:41 Voltage Offset Correction: v_off_ini = 919.808 uV, v_off_fin = 915.612 uV 13:19:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.239 uVs 13:19:43 I2Y Average and RMS of Measurements VT = -242.169 +- 2.734 uVs I2Y = -22.280 +- 0.252 uTm^2 13:19:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:19:52 Integrated Voltage Measurement... 13:20:01 Voltage Offset Correction: v_off_ini = 893.662 uV, v_off_fin = 897.583 uV 13:20:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -77.439 uVs 13:20:01 Integrated Voltage Measurement... 13:20:10 Voltage Offset Correction: v_off_ini = 898.009 uV, v_off_fin = 915.880 uV 13:20:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.228 uVs 13:20:10 Integrated Voltage Measurement... 13:20:19 Voltage Offset Correction: v_off_ini = 873.239 uV, v_off_fin = 902.729 uV 13:20:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.710 uVs 13:20:19 Integrated Voltage Measurement... 13:20:28 Voltage Offset Correction: v_off_ini = 903.198 uV, v_off_fin = 904.252 uV 13:20:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.853 uVs 13:20:28 Integrated Voltage Measurement... 13:20:37 Voltage Offset Correction: v_off_ini = 893.603 uV, v_off_fin = 885.523 uV 13:20:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.296 uVs 13:20:37 Integrated Voltage Measurement... 13:20:46 Voltage Offset Correction: v_off_ini = 906.451 uV, v_off_fin = 905.533 uV 13:20:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.548 uVs 13:20:50 I1X Average and RMS of Measurements VT = -99.512 +- 8.165 uVs I1X = 19.903 +- 1.633 uTm 13:20:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:20:57 Integrated Voltage Measurement... 13:21:06 Voltage Offset Correction: v_off_ini = 893.930 uV, v_off_fin = 900.174 uV 13:21:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.316 uVs 13:21:06 Integrated Voltage Measurement... 13:21:15 Voltage Offset Correction: v_off_ini = 903.439 uV, v_off_fin = 891.930 uV 13:21:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.798 uVs 13:21:15 Integrated Voltage Measurement... 13:21:24 Voltage Offset Correction: v_off_ini = 890.033 uV, v_off_fin = 888.279 uV 13:21:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.878 uVs 13:21:24 Integrated Voltage Measurement... 13:21:33 Voltage Offset Correction: v_off_ini = 904.666 uV, v_off_fin = 915.316 uV 13:21:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.228 uVs 13:21:33 Integrated Voltage Measurement... 13:21:42 Voltage Offset Correction: v_off_ini = 908.184 uV, v_off_fin = 904.279 uV 13:21:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.444 uVs 13:21:42 Integrated Voltage Measurement... 13:21:51 Voltage Offset Correction: v_off_ini = 904.102 uV, v_off_fin = 909.603 uV 13:21:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.979 uVs 13:21:55 I1Y Average and RMS of Measurements VT = -231.440 +- 3.136 uVs I1Y = -46.288 +- 0.627 uTm 13:21:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:22:00 Integrated Voltage Measurement... 13:22:09 Voltage Offset Correction: v_off_ini = 878.325 uV, v_off_fin = 875.087 uV 13:22:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.522 uVs 13:22:09 Integrated Voltage Measurement... 13:22:18 Voltage Offset Correction: v_off_ini = 906.656 uV, v_off_fin = 898.338 uV 13:22:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.704 uVs 13:22:18 Integrated Voltage Measurement... 13:22:27 Voltage Offset Correction: v_off_ini = 867.108 uV, v_off_fin = 898.883 uV 13:22:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.298 uVs 13:22:27 Integrated Voltage Measurement... 13:22:36 Voltage Offset Correction: v_off_ini = 931.232 uV, v_off_fin = 939.499 uV 13:22:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.713 uVs 13:22:36 Integrated Voltage Measurement... 13:22:45 Voltage Offset Correction: v_off_ini = 920.923 uV, v_off_fin = 901.992 uV 13:22:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.374 uVs 13:22:45 Integrated Voltage Measurement... 13:22:54 Voltage Offset Correction: v_off_ini = 915.056 uV, v_off_fin = 921.365 uV 13:22:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.905 uVs 13:22:57 I2X Average and RMS of Measurements VT = -109.253 +- 11.463 uVs I2X = 10.051 +- 1.055 uTm^2 13:22:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:23:02 Integrated Voltage Measurement... 13:23:11 Voltage Offset Correction: v_off_ini = 938.161 uV, v_off_fin = 899.722 uV 13:23:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.419 uVs 13:23:11 Integrated Voltage Measurement... 13:23:20 Voltage Offset Correction: v_off_ini = 894.558 uV, v_off_fin = 905.364 uV 13:23:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.576 uVs 13:23:20 Integrated Voltage Measurement... 13:23:29 Voltage Offset Correction: v_off_ini = 916.969 uV, v_off_fin = 889.222 uV 13:23:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.655 uVs 13:23:29 Integrated Voltage Measurement... 13:23:38 Voltage Offset Correction: v_off_ini = 921.641 uV, v_off_fin = 919.365 uV 13:23:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.065 uVs 13:23:38 Integrated Voltage Measurement... 13:23:47 Voltage Offset Correction: v_off_ini = 926.350 uV, v_off_fin = 929.129 uV 13:23:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.743 uVs 13:23:47 Integrated Voltage Measurement... 13:23:56 Voltage Offset Correction: v_off_ini = 928.507 uV, v_off_fin = 924.384 uV 13:23:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.372 uVs 13:23:59 I2Y Average and RMS of Measurements VT = -239.971 +- 1.790 uVs I2Y = -22.077 +- 0.165 uTm^2 13:24:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:24:07 Integrated Voltage Measurement... 13:24:16 Voltage Offset Correction: v_off_ini = 937.205 uV, v_off_fin = 929.131 uV 13:24:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -121.096 uVs 13:24:16 Integrated Voltage Measurement... 13:24:25 Voltage Offset Correction: v_off_ini = 937.384 uV, v_off_fin = 932.558 uV 13:24:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.010 uVs 13:24:25 Integrated Voltage Measurement... 13:24:34 Voltage Offset Correction: v_off_ini = 902.806 uV, v_off_fin = 928.708 uV 13:24:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.639 uVs 13:24:34 Integrated Voltage Measurement... 13:24:43 Voltage Offset Correction: v_off_ini = 899.430 uV, v_off_fin = 917.385 uV 13:24:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.125 uVs 13:24:43 Integrated Voltage Measurement... 13:24:52 Voltage Offset Correction: v_off_ini = 929.450 uV, v_off_fin = 929.673 uV 13:24:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.447 uVs 13:24:52 Integrated Voltage Measurement... 13:25:01 Voltage Offset Correction: v_off_ini = 931.220 uV, v_off_fin = 919.638 uV 13:25:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.508 uVs 13:25:05 I1X Average and RMS of Measurements VT = -94.304 +- 15.730 uVs I1X = 18.861 +- 3.147 uTm 13:25:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:25:12 Integrated Voltage Measurement... 13:25:21 Voltage Offset Correction: v_off_ini = 895.704 uV, v_off_fin = 875.299 uV 13:25:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -233.238 uVs 13:25:21 Integrated Voltage Measurement... 13:25:30 Voltage Offset Correction: v_off_ini = 899.230 uV, v_off_fin = 908.852 uV 13:25:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.605 uVs 13:25:30 Integrated Voltage Measurement... 13:25:39 Voltage Offset Correction: v_off_ini = 917.018 uV, v_off_fin = 914.368 uV 13:25:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.641 uVs 13:25:39 Integrated Voltage Measurement... 13:25:48 Voltage Offset Correction: v_off_ini = 898.228 uV, v_off_fin = 918.242 uV 13:25:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.681 uVs 13:25:48 Integrated Voltage Measurement... 13:25:57 Voltage Offset Correction: v_off_ini = 911.344 uV, v_off_fin = 904.698 uV 13:25:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.330 uVs 13:25:57 Integrated Voltage Measurement... 13:26:06 Voltage Offset Correction: v_off_ini = 908.538 uV, v_off_fin = 936.791 uV 13:26:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.296 uVs 13:26:10 I1Y Average and RMS of Measurements VT = -226.299 +- 1.573 uVs I1Y = -45.260 +- 0.317 uTm 13:26:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:26:15 Integrated Voltage Measurement... 13:26:24 Voltage Offset Correction: v_off_ini = 903.749 uV, v_off_fin = 907.743 uV 13:26:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.172 uVs 13:26:25 Integrated Voltage Measurement... 13:26:34 Voltage Offset Correction: v_off_ini = 908.736 uV, v_off_fin = 925.098 uV 13:26:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.733 uVs 13:26:34 Integrated Voltage Measurement... 13:26:43 Voltage Offset Correction: v_off_ini = 923.564 uV, v_off_fin = 907.993 uV 13:26:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.130 uVs 13:26:43 Integrated Voltage Measurement... 13:26:52 Voltage Offset Correction: v_off_ini = 903.478 uV, v_off_fin = 910.551 uV 13:26:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.749 uVs 13:26:52 Integrated Voltage Measurement... 13:27:01 Voltage Offset Correction: v_off_ini = 896.363 uV, v_off_fin = 886.797 uV 13:27:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.562 uVs 13:27:01 Integrated Voltage Measurement... 13:27:10 Voltage Offset Correction: v_off_ini = 871.902 uV, v_off_fin = 872.301 uV 13:27:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.516 uVs 13:27:12 I2X Average and RMS of Measurements VT = -125.311 +- 14.380 uVs I2X = 11.529 +- 1.323 uTm^2 13:27:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:27:17 Integrated Voltage Measurement... 13:27:26 Voltage Offset Correction: v_off_ini = 875.647 uV, v_off_fin = 869.051 uV 13:27:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.656 uVs 13:27:26 Integrated Voltage Measurement... 13:27:35 Voltage Offset Correction: v_off_ini = 883.711 uV, v_off_fin = 853.319 uV 13:27:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.459 uVs 13:27:35 Integrated Voltage Measurement... 13:27:44 Voltage Offset Correction: v_off_ini = 853.862 uV, v_off_fin = 865.263 uV 13:27:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.267 uVs 13:27:44 Integrated Voltage Measurement... 13:27:53 Voltage Offset Correction: v_off_ini = 875.807 uV, v_off_fin = 881.828 uV 13:27:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.001 uVs 13:27:53 Integrated Voltage Measurement... 13:28:02 Voltage Offset Correction: v_off_ini = 872.839 uV, v_off_fin = 869.627 uV 13:28:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.813 uVs 13:28:03 Integrated Voltage Measurement... 13:28:12 Voltage Offset Correction: v_off_ini = 872.419 uV, v_off_fin = 873.857 uV 13:28:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.789 uVs 13:28:14 I2Y Average and RMS of Measurements VT = -239.498 +- 5.887 uVs I2Y = -22.034 +- 0.542 uTm^2 13:28:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:28:22 Integrated Voltage Measurement... 13:28:31 Voltage Offset Correction: v_off_ini = 865.249 uV, v_off_fin = 850.681 uV 13:28:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -112.199 uVs 13:28:31 Integrated Voltage Measurement... 13:28:40 Voltage Offset Correction: v_off_ini = 851.686 uV, v_off_fin = 853.200 uV 13:28:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.997 uVs 13:28:40 Integrated Voltage Measurement... 13:28:49 Voltage Offset Correction: v_off_ini = 871.422 uV, v_off_fin = 863.367 uV 13:28:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.331 uVs 13:28:49 Integrated Voltage Measurement... 13:28:58 Voltage Offset Correction: v_off_ini = 854.743 uV, v_off_fin = 875.792 uV 13:28:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.177 uVs 13:28:58 Integrated Voltage Measurement... 13:29:07 Voltage Offset Correction: v_off_ini = 882.841 uV, v_off_fin = 857.354 uV 13:29:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.808 uVs 13:29:07 Integrated Voltage Measurement... 13:29:16 Voltage Offset Correction: v_off_ini = 866.753 uV, v_off_fin = 861.862 uV 13:29:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.103 uVs 13:29:21 I1X Average and RMS of Measurements VT = -97.603 +- 3.204 uVs I1X = 19.521 +- 0.641 uTm 13:29:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:29:27 Integrated Voltage Measurement... 13:29:36 Voltage Offset Correction: v_off_ini = 871.239 uV, v_off_fin = 847.638 uV 13:29:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -235.169 uVs 13:29:36 Integrated Voltage Measurement... 13:29:45 Voltage Offset Correction: v_off_ini = 845.638 uV, v_off_fin = 865.508 uV 13:29:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.810 uVs 13:29:45 Integrated Voltage Measurement... 13:29:54 Voltage Offset Correction: v_off_ini = 843.317 uV, v_off_fin = 840.025 uV 13:29:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.071 uVs 13:29:54 Integrated Voltage Measurement... 13:30:03 Voltage Offset Correction: v_off_ini = 854.985 uV, v_off_fin = 865.241 uV 13:30:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 228.411 uVs 13:30:03 Integrated Voltage Measurement... 13:30:12 Voltage Offset Correction: v_off_ini = 856.219 uV, v_off_fin = 844.416 uV 13:30:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -232.348 uVs 13:30:13 Integrated Voltage Measurement... 13:30:21 Voltage Offset Correction: v_off_ini = 872.252 uV, v_off_fin = 896.754 uV 13:30:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 228.262 uVs 13:30:26 I1Y Average and RMS of Measurements VT = -228.345 +- 7.578 uVs I1Y = -45.664 +- 1.517 uTm 13:30:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:30:31 Integrated Voltage Measurement... 13:30:40 Voltage Offset Correction: v_off_ini = 868.231 uV, v_off_fin = 859.380 uV 13:30:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -113.401 uVs 13:30:40 Integrated Voltage Measurement... 13:30:49 Voltage Offset Correction: v_off_ini = 869.792 uV, v_off_fin = 884.109 uV 13:30:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.720 uVs 13:30:49 Integrated Voltage Measurement... 13:30:58 Voltage Offset Correction: v_off_ini = 889.056 uV, v_off_fin = 883.281 uV 13:30:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.016 uVs 13:30:58 Integrated Voltage Measurement... 13:31:07 Voltage Offset Correction: v_off_ini = 895.218 uV, v_off_fin = 907.762 uV 13:31:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.510 uVs 13:31:07 Integrated Voltage Measurement... 13:31:16 Voltage Offset Correction: v_off_ini = 884.813 uV, v_off_fin = 882.062 uV 13:31:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.335 uVs 13:31:16 Integrated Voltage Measurement... 13:31:25 Voltage Offset Correction: v_off_ini = 898.545 uV, v_off_fin = 893.212 uV 13:31:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.242 uVs 13:31:27 I2X Average and RMS of Measurements VT = -104.537 +- 6.721 uVs I2X = 9.618 +- 0.619 uTm^2 13:31:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:31:33 Integrated Voltage Measurement... 13:31:42 Voltage Offset Correction: v_off_ini = 880.053 uV, v_off_fin = 895.161 uV 13:31:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.345 uVs 13:31:42 Integrated Voltage Measurement... 13:31:51 Voltage Offset Correction: v_off_ini = 887.068 uV, v_off_fin = 897.745 uV 13:31:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.863 uVs 13:31:51 Integrated Voltage Measurement... 13:32:00 Voltage Offset Correction: v_off_ini = 895.482 uV, v_off_fin = 873.599 uV 13:32:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.618 uVs 13:32:00 Integrated Voltage Measurement... 13:32:09 Voltage Offset Correction: v_off_ini = 889.483 uV, v_off_fin = 895.108 uV 13:32:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.219 uVs 13:32:09 Integrated Voltage Measurement... 13:32:18 Voltage Offset Correction: v_off_ini = 900.147 uV, v_off_fin = 921.283 uV 13:32:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.981 uVs 13:32:18 Integrated Voltage Measurement... 13:32:27 Voltage Offset Correction: v_off_ini = 906.714 uV, v_off_fin = 909.606 uV 13:32:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.419 uVs 13:32:29 I2Y Average and RMS of Measurements VT = -235.074 +- 5.891 uVs I2Y = -21.627 +- 0.542 uTm^2 13:32:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:32:50 Integrated Voltage Measurement... 13:32:59 Voltage Offset Correction: v_off_ini = 913.370 uV, v_off_fin = 905.187 uV 13:32:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -152.512 uVs 13:32:59 Integrated Voltage Measurement... 13:33:08 Voltage Offset Correction: v_off_ini = 907.667 uV, v_off_fin = 901.892 uV 13:33:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.863 uVs 13:33:08 Integrated Voltage Measurement... 13:33:17 Voltage Offset Correction: v_off_ini = 903.274 uV, v_off_fin = 913.387 uV 13:33:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.405 uVs 13:33:17 Integrated Voltage Measurement... 13:33:26 Voltage Offset Correction: v_off_ini = 919.331 uV, v_off_fin = 923.193 uV 13:33:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.196 uVs 13:33:26 Integrated Voltage Measurement... 13:33:35 Voltage Offset Correction: v_off_ini = 910.024 uV, v_off_fin = 935.325 uV 13:33:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.914 uVs 13:33:35 Integrated Voltage Measurement... 13:33:44 Voltage Offset Correction: v_off_ini = 927.617 uV, v_off_fin = 917.141 uV 13:33:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.317 uVs 13:33:48 I1X Average and RMS of Measurements VT = -125.868 +- 15.116 uVs I1X = 25.175 +- 3.025 uTm 13:33:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:33:55 Integrated Voltage Measurement... 13:34:04 Voltage Offset Correction: v_off_ini = 904.823 uV, v_off_fin = 902.562 uV 13:34:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.974 uVs 13:34:04 Integrated Voltage Measurement... 13:34:13 Voltage Offset Correction: v_off_ini = 894.903 uV, v_off_fin = 917.481 uV 13:34:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.145 uVs 13:34:13 Integrated Voltage Measurement... 13:34:22 Voltage Offset Correction: v_off_ini = 912.762 uV, v_off_fin = 900.035 uV 13:34:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.523 uVs 13:34:22 Integrated Voltage Measurement... 13:34:31 Voltage Offset Correction: v_off_ini = 917.076 uV, v_off_fin = 918.980 uV 13:34:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.741 uVs 13:34:31 Integrated Voltage Measurement... 13:34:40 Voltage Offset Correction: v_off_ini = 925.112 uV, v_off_fin = 894.695 uV 13:34:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.979 uVs 13:34:40 Integrated Voltage Measurement... 13:34:49 Voltage Offset Correction: v_off_ini = 912.936 uV, v_off_fin = 927.619 uV 13:34:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.915 uVs 13:34:53 I1Y Average and RMS of Measurements VT = -229.879 +- 2.371 uVs I1Y = -45.976 +- 0.474 uTm 13:34:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:35:01 Integrated Voltage Measurement... 13:35:10 Voltage Offset Correction: v_off_ini = 903.257 uV, v_off_fin = 905.793 uV 13:35:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.580 uVs 13:35:10 Integrated Voltage Measurement... 13:35:19 Voltage Offset Correction: v_off_ini = 921.693 uV, v_off_fin = 924.864 uV 13:35:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.411 uVs 13:35:19 Integrated Voltage Measurement... 13:35:28 Voltage Offset Correction: v_off_ini = 926.580 uV, v_off_fin = 918.262 uV 13:35:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.499 uVs 13:35:28 Integrated Voltage Measurement... 13:35:37 Voltage Offset Correction: v_off_ini = 922.432 uV, v_off_fin = 935.221 uV 13:35:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.221 uVs 13:35:37 Integrated Voltage Measurement... 13:35:46 Voltage Offset Correction: v_off_ini = 907.587 uV, v_off_fin = 907.155 uV 13:35:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.738 uVs 13:35:46 Integrated Voltage Measurement... 13:35:55 Voltage Offset Correction: v_off_ini = 911.935 uV, v_off_fin = 900.678 uV 13:35:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.855 uVs 13:35:57 I2X Average and RMS of Measurements VT = -138.718 +- 4.094 uVs I2X = 12.762 +- 0.377 uTm^2 13:36:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:36:05 Integrated Voltage Measurement... 13:36:14 Voltage Offset Correction: v_off_ini = 923.059 uV, v_off_fin = 913.486 uV 13:36:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.581 uVs 13:36:14 Integrated Voltage Measurement... 13:36:23 Voltage Offset Correction: v_off_ini = 930.246 uV, v_off_fin = 933.190 uV 13:36:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.847 uVs 13:36:23 Integrated Voltage Measurement... 13:36:32 Voltage Offset Correction: v_off_ini = 930.533 uV, v_off_fin = 926.695 uV 13:36:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.352 uVs 13:36:32 Integrated Voltage Measurement... 13:36:41 Voltage Offset Correction: v_off_ini = 928.507 uV, v_off_fin = 924.017 uV 13:36:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.113 uVs 13:36:41 Integrated Voltage Measurement... 13:36:50 Voltage Offset Correction: v_off_ini = 919.354 uV, v_off_fin = 906.293 uV 13:36:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.322 uVs 13:36:50 Integrated Voltage Measurement... 13:36:59 Voltage Offset Correction: v_off_ini = 921.174 uV, v_off_fin = 903.354 uV 13:36:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.447 uVs 13:37:02 I2Y Average and RMS of Measurements VT = -242.610 +- 9.847 uVs I2Y = -22.320 +- 0.906 uTm^2 13:37:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:37:11 Integrated Voltage Measurement... 13:37:20 Voltage Offset Correction: v_off_ini = 923.799 uV, v_off_fin = 924.427 uV 13:37:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.385 uVs 13:37:20 Integrated Voltage Measurement... 13:37:29 Voltage Offset Correction: v_off_ini = 900.415 uV, v_off_fin = 916.601 uV 13:37:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.481 uVs 13:37:29 Integrated Voltage Measurement... 13:37:38 Voltage Offset Correction: v_off_ini = 918.402 uV, v_off_fin = 924.577 uV 13:37:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.919 uVs 13:37:38 Integrated Voltage Measurement... 13:37:47 Voltage Offset Correction: v_off_ini = 921.149 uV, v_off_fin = 911.715 uV 13:37:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.850 uVs 13:37:47 Integrated Voltage Measurement... 13:37:56 Voltage Offset Correction: v_off_ini = 912.192 uV, v_off_fin = 947.894 uV 13:37:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.155 uVs 13:37:56 Integrated Voltage Measurement... 13:38:05 Voltage Offset Correction: v_off_ini = 912.931 uV, v_off_fin = 914.681 uV 13:38:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.242 uVs 13:38:09 I1X Average and RMS of Measurements VT = -131.339 +- 15.911 uVs I1X = 26.268 +- 3.182 uTm 13:38:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:38:16 Integrated Voltage Measurement... 13:38:25 Voltage Offset Correction: v_off_ini = 928.386 uV, v_off_fin = 909.772 uV 13:38:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.156 uVs 13:38:25 Integrated Voltage Measurement... 13:38:34 Voltage Offset Correction: v_off_ini = 933.050 uV, v_off_fin = 928.098 uV 13:38:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.454 uVs 13:38:34 Integrated Voltage Measurement... 13:38:43 Voltage Offset Correction: v_off_ini = 895.240 uV, v_off_fin = 914.210 uV 13:38:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.177 uVs 13:38:43 Integrated Voltage Measurement... 13:38:52 Voltage Offset Correction: v_off_ini = 906.907 uV, v_off_fin = 917.236 uV 13:38:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.375 uVs 13:38:52 Integrated Voltage Measurement... 13:39:01 Voltage Offset Correction: v_off_ini = 886.816 uV, v_off_fin = 894.919 uV 13:39:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.929 uVs 13:39:01 Integrated Voltage Measurement... 13:39:10 Voltage Offset Correction: v_off_ini = 908.190 uV, v_off_fin = 923.701 uV 13:39:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.754 uVs 13:39:14 I1Y Average and RMS of Measurements VT = -227.474 +- 4.707 uVs I1Y = -45.495 +- 0.941 uTm 13:39:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:39:22 Integrated Voltage Measurement... 13:39:31 Voltage Offset Correction: v_off_ini = 923.695 uV, v_off_fin = 911.374 uV 13:39:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -135.539 uVs 13:39:31 Integrated Voltage Measurement... 13:39:40 Voltage Offset Correction: v_off_ini = 893.548 uV, v_off_fin = 908.129 uV 13:39:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.871 uVs 13:39:40 Integrated Voltage Measurement... 13:39:49 Voltage Offset Correction: v_off_ini = 889.583 uV, v_off_fin = 892.976 uV 13:39:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.047 uVs 13:39:49 Integrated Voltage Measurement... 13:39:58 Voltage Offset Correction: v_off_ini = 905.474 uV, v_off_fin = 920.312 uV 13:39:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.376 uVs 13:39:58 Integrated Voltage Measurement... 13:40:07 Voltage Offset Correction: v_off_ini = 918.869 uV, v_off_fin = 903.614 uV 13:40:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.178 uVs 13:40:07 Integrated Voltage Measurement... 13:40:16 Voltage Offset Correction: v_off_ini = 926.205 uV, v_off_fin = 921.047 uV 13:40:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.020 uVs 13:40:19 I2X Average and RMS of Measurements VT = -128.505 +- 4.516 uVs I2X = 11.822 +- 0.416 uTm^2 13:40:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:40:26 Integrated Voltage Measurement... 13:40:35 Voltage Offset Correction: v_off_ini = 931.875 uV, v_off_fin = 948.030 uV 13:40:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.610 uVs 13:40:35 Integrated Voltage Measurement... 13:40:44 Voltage Offset Correction: v_off_ini = 952.127 uV, v_off_fin = 927.792 uV 13:40:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 263.008 uVs 13:40:44 Integrated Voltage Measurement... 13:40:53 Voltage Offset Correction: v_off_ini = 929.265 uV, v_off_fin = 932.044 uV 13:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.585 uVs 13:40:53 Integrated Voltage Measurement... 13:41:02 Voltage Offset Correction: v_off_ini = 923.916 uV, v_off_fin = 929.904 uV 13:41:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.555 uVs 13:41:02 Integrated Voltage Measurement... 13:41:11 Voltage Offset Correction: v_off_ini = 936.905 uV, v_off_fin = 932.433 uV 13:41:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.919 uVs 13:41:12 Integrated Voltage Measurement... 13:41:21 Voltage Offset Correction: v_off_ini = 912.098 uV, v_off_fin = 905.727 uV 13:41:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.196 uVs 13:41:23 I2Y Average and RMS of Measurements VT = -245.812 +- 9.057 uVs I2Y = -22.615 +- 0.834 uTm^2 13:41:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:41:32 Integrated Voltage Measurement... 13:41:41 Voltage Offset Correction: v_off_ini = 933.700 uV, v_off_fin = 920.517 uV 13:41:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.923 uVs 13:41:41 Integrated Voltage Measurement... 13:41:50 Voltage Offset Correction: v_off_ini = 933.026 uV, v_off_fin = 900.692 uV 13:41:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.365 uVs 13:41:50 Integrated Voltage Measurement... 13:41:59 Voltage Offset Correction: v_off_ini = 922.792 uV, v_off_fin = 923.256 uV 13:41:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.561 uVs 13:41:59 Integrated Voltage Measurement... 13:42:08 Voltage Offset Correction: v_off_ini = 932.403 uV, v_off_fin = 927.116 uV 13:42:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.942 uVs 13:42:08 Integrated Voltage Measurement... 13:42:17 Voltage Offset Correction: v_off_ini = 915.849 uV, v_off_fin = 918.802 uV 13:42:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.231 uVs 13:42:17 Integrated Voltage Measurement... 13:42:26 Voltage Offset Correction: v_off_ini = 915.981 uV, v_off_fin = 902.543 uV 13:42:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.095 uVs 13:42:30 I1X Average and RMS of Measurements VT = -135.686 +- 10.932 uVs I1X = 27.137 +- 2.186 uTm 13:42:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:42:37 Integrated Voltage Measurement... 13:42:46 Voltage Offset Correction: v_off_ini = 914.641 uV, v_off_fin = 914.590 uV 13:42:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.188 uVs 13:42:46 Integrated Voltage Measurement... 13:42:55 Voltage Offset Correction: v_off_ini = 934.791 uV, v_off_fin = 956.132 uV 13:42:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.365 uVs 13:42:56 Integrated Voltage Measurement... 13:43:05 Voltage Offset Correction: v_off_ini = 916.099 uV, v_off_fin = 917.773 uV 13:43:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.863 uVs 13:43:05 Integrated Voltage Measurement... 13:43:14 Voltage Offset Correction: v_off_ini = 947.108 uV, v_off_fin = 954.410 uV 13:43:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.751 uVs 13:43:14 Integrated Voltage Measurement... 13:43:23 Voltage Offset Correction: v_off_ini = 943.133 uV, v_off_fin = 933.986 uV 13:43:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.246 uVs 13:43:23 Integrated Voltage Measurement... 13:43:32 Voltage Offset Correction: v_off_ini = 926.079 uV, v_off_fin = 932.001 uV 13:43:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.594 uVs 13:43:36 I1Y Average and RMS of Measurements VT = -223.001 +- 3.150 uVs I1Y = -44.600 +- 0.630 uTm 13:43:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:43:44 Integrated Voltage Measurement... 13:43:53 Voltage Offset Correction: v_off_ini = 936.664 uV, v_off_fin = 940.389 uV 13:43:53 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -126.599 uVs 13:43:53 Integrated Voltage Measurement... 13:44:02 Voltage Offset Correction: v_off_ini = 929.091 uV, v_off_fin = 932.178 uV 13:44:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 164.672 uVs 13:44:02 Integrated Voltage Measurement... 13:44:11 Voltage Offset Correction: v_off_ini = 929.334 uV, v_off_fin = 923.905 uV 13:44:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.805 uVs 13:44:11 Integrated Voltage Measurement... 13:44:20 Voltage Offset Correction: v_off_ini = 927.441 uV, v_off_fin = 936.682 uV 13:44:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.334 uVs 13:44:20 Integrated Voltage Measurement... 13:44:29 Voltage Offset Correction: v_off_ini = 907.262 uV, v_off_fin = 909.391 uV 13:44:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.045 uVs 13:44:29 Integrated Voltage Measurement... 13:44:38 Voltage Offset Correction: v_off_ini = 940.085 uV, v_off_fin = 951.421 uV 13:44:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.091 uVs 13:44:40 I2X Average and RMS of Measurements VT = -131.758 +- 10.708 uVs I2X = 12.122 +- 0.985 uTm^2 13:44:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:44:48 Integrated Voltage Measurement... 13:44:57 Voltage Offset Correction: v_off_ini = 935.681 uV, v_off_fin = 918.882 uV 13:44:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.765 uVs 13:44:57 Integrated Voltage Measurement... 13:45:06 Voltage Offset Correction: v_off_ini = 894.466 uV, v_off_fin = 918.641 uV 13:45:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.287 uVs 13:45:06 Integrated Voltage Measurement... 13:45:15 Voltage Offset Correction: v_off_ini = 926.460 uV, v_off_fin = 937.774 uV 13:45:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.078 uVs 13:45:15 Integrated Voltage Measurement... 13:45:24 Voltage Offset Correction: v_off_ini = 931.357 uV, v_off_fin = 933.262 uV 13:45:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.906 uVs 13:45:24 Integrated Voltage Measurement... 13:45:33 Voltage Offset Correction: v_off_ini = 928.391 uV, v_off_fin = 914.481 uV 13:45:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.592 uVs 13:45:33 Integrated Voltage Measurement... 13:45:42 Voltage Offset Correction: v_off_ini = 924.788 uV, v_off_fin = 913.545 uV 13:45:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.319 uVs 13:45:45 I2Y Average and RMS of Measurements VT = -238.491 +- 8.924 uVs I2Y = -21.941 +- 0.821 uTm^2 13:45:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:45:54 Integrated Voltage Measurement... 13:46:02 Voltage Offset Correction: v_off_ini = 911.553 uV, v_off_fin = 916.208 uV 13:46:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.852 uVs 13:46:03 Integrated Voltage Measurement... 13:46:12 Voltage Offset Correction: v_off_ini = 913.920 uV, v_off_fin = 925.764 uV 13:46:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.701 uVs 13:46:12 Integrated Voltage Measurement... 13:46:21 Voltage Offset Correction: v_off_ini = 921.482 uV, v_off_fin = 930.607 uV 13:46:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.046 uVs 13:46:21 Integrated Voltage Measurement... 13:46:30 Voltage Offset Correction: v_off_ini = 920.970 uV, v_off_fin = 926.226 uV 13:46:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 119.942 uVs 13:46:30 Integrated Voltage Measurement... 13:46:39 Voltage Offset Correction: v_off_ini = 912.560 uV, v_off_fin = 918.406 uV 13:46:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -88.316 uVs 13:46:39 Integrated Voltage Measurement... 13:46:48 Voltage Offset Correction: v_off_ini = 906.525 uV, v_off_fin = 918.551 uV 13:46:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.739 uVs 13:46:52 I1X Average and RMS of Measurements VT = -110.599 +- 8.962 uVs I1X = 22.121 +- 1.792 uTm 13:46:54 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:46:59 Integrated Voltage Measurement... 13:47:08 Voltage Offset Correction: v_off_ini = 920.545 uV, v_off_fin = 915.595 uV 13:47:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -235.737 uVs 13:47:08 Integrated Voltage Measurement... 13:47:17 Voltage Offset Correction: v_off_ini = 920.949 uV, v_off_fin = 929.285 uV 13:47:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.957 uVs 13:47:17 Integrated Voltage Measurement... 13:47:26 Voltage Offset Correction: v_off_ini = 934.400 uV, v_off_fin = 907.861 uV 13:47:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.345 uVs 13:47:26 Integrated Voltage Measurement... 13:47:35 Voltage Offset Correction: v_off_ini = 935.084 uV, v_off_fin = 950.574 uV 13:47:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.634 uVs 13:47:35 Integrated Voltage Measurement... 13:47:44 Voltage Offset Correction: v_off_ini = 918.350 uV, v_off_fin = 903.988 uV 13:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.932 uVs 13:47:44 Integrated Voltage Measurement... 13:47:53 Voltage Offset Correction: v_off_ini = 920.161 uV, v_off_fin = 920.815 uV 13:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.671 uVs 13:47:57 I1Y Average and RMS of Measurements VT = -234.713 +- 3.494 uVs I1Y = -46.943 +- 0.700 uTm 13:48:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:48:05 Integrated Voltage Measurement... 13:48:14 Voltage Offset Correction: v_off_ini = 921.765 uV, v_off_fin = 898.662 uV 13:48:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -103.040 uVs 13:48:14 Integrated Voltage Measurement... 13:48:23 Voltage Offset Correction: v_off_ini = 911.560 uV, v_off_fin = 904.023 uV 13:48:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.206 uVs 13:48:23 Integrated Voltage Measurement... 13:48:32 Voltage Offset Correction: v_off_ini = 896.311 uV, v_off_fin = 900.081 uV 13:48:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.118 uVs 13:48:32 Integrated Voltage Measurement... 13:48:41 Voltage Offset Correction: v_off_ini = 905.451 uV, v_off_fin = 905.970 uV 13:48:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.943 uVs 13:48:41 Integrated Voltage Measurement... 13:48:50 Voltage Offset Correction: v_off_ini = 907.834 uV, v_off_fin = 910.749 uV 13:48:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.775 uVs 13:48:50 Integrated Voltage Measurement... 13:48:59 Voltage Offset Correction: v_off_ini = 921.122 uV, v_off_fin = 951.984 uV 13:48:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.181 uVs 13:49:01 I2X Average and RMS of Measurements VT = -126.377 +- 4.055 uVs I2X = 11.627 +- 0.373 uTm^2 13:49:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:49:09 Integrated Voltage Measurement... 13:49:18 Voltage Offset Correction: v_off_ini = 931.657 uV, v_off_fin = 920.335 uV 13:49:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.384 uVs 13:49:18 Integrated Voltage Measurement... 13:49:27 Voltage Offset Correction: v_off_ini = 921.826 uV, v_off_fin = 918.947 uV 13:49:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.406 uVs 13:49:27 Integrated Voltage Measurement... 13:49:36 Voltage Offset Correction: v_off_ini = 890.324 uV, v_off_fin = 912.049 uV 13:49:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.814 uVs 13:49:36 Integrated Voltage Measurement... 13:49:45 Voltage Offset Correction: v_off_ini = 912.792 uV, v_off_fin = 898.755 uV 13:49:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.907 uVs 13:49:45 Integrated Voltage Measurement... 13:49:54 Voltage Offset Correction: v_off_ini = 908.746 uV, v_off_fin = 916.336 uV 13:49:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.439 uVs 13:49:54 Integrated Voltage Measurement... 13:50:03 Voltage Offset Correction: v_off_ini = 902.266 uV, v_off_fin = 921.490 uV 13:50:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.921 uVs 13:50:06 I2Y Average and RMS of Measurements VT = -233.645 +- 5.509 uVs I2Y = -21.495 +- 0.507 uTm^2 13:50:10 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:50:15 Integrated Voltage Measurement... 13:50:24 Voltage Offset Correction: v_off_ini = 934.707 uV, v_off_fin = 907.921 uV 13:50:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.084 uVs 13:50:24 Integrated Voltage Measurement... 13:50:33 Voltage Offset Correction: v_off_ini = 919.153 uV, v_off_fin = 926.707 uV 13:50:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.909 uVs 13:50:33 Integrated Voltage Measurement... 13:50:42 Voltage Offset Correction: v_off_ini = 927.785 uV, v_off_fin = 908.544 uV 13:50:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.932 uVs 13:50:42 Integrated Voltage Measurement... 13:50:51 Voltage Offset Correction: v_off_ini = 894.609 uV, v_off_fin = 918.213 uV 13:50:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.611 uVs 13:50:51 Integrated Voltage Measurement... 13:51:00 Voltage Offset Correction: v_off_ini = 934.056 uV, v_off_fin = 916.960 uV 13:51:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.062 uVs 13:51:00 Integrated Voltage Measurement... 13:51:09 Voltage Offset Correction: v_off_ini = 904.677 uV, v_off_fin = 908.856 uV 13:51:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.190 uVs 13:51:13 I1X Average and RMS of Measurements VT = -117.631 +- 1.693 uVs I1X = 23.526 +- 0.339 uTm 13:51:15 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:51:20 Integrated Voltage Measurement... 13:51:29 Voltage Offset Correction: v_off_ini = 910.902 uV, v_off_fin = 892.835 uV 13:51:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.084 uVs 13:51:29 Integrated Voltage Measurement... 13:51:38 Voltage Offset Correction: v_off_ini = 902.019 uV, v_off_fin = 924.813 uV 13:51:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.898 uVs 13:51:38 Integrated Voltage Measurement... 13:51:47 Voltage Offset Correction: v_off_ini = 918.332 uV, v_off_fin = 920.307 uV 13:51:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.600 uVs 13:51:47 Integrated Voltage Measurement... 13:51:56 Voltage Offset Correction: v_off_ini = 921.797 uV, v_off_fin = 917.115 uV 13:51:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.527 uVs 13:51:56 Integrated Voltage Measurement... 13:52:05 Voltage Offset Correction: v_off_ini = 918.736 uV, v_off_fin = 901.740 uV 13:52:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.031 uVs 13:52:05 Integrated Voltage Measurement... 13:52:14 Voltage Offset Correction: v_off_ini = 919.025 uV, v_off_fin = 939.788 uV 13:52:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.097 uVs 13:52:18 I1Y Average and RMS of Measurements VT = -224.040 +- 11.863 uVs I1Y = -44.808 +- 2.373 uTm 13:52:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:52:26 Integrated Voltage Measurement... 13:52:35 Voltage Offset Correction: v_off_ini = 917.287 uV, v_off_fin = 915.971 uV 13:52:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -86.607 uVs 13:52:35 Integrated Voltage Measurement... 13:52:44 Voltage Offset Correction: v_off_ini = 917.186 uV, v_off_fin = 930.630 uV 13:52:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.647 uVs 13:52:44 Integrated Voltage Measurement... 13:52:53 Voltage Offset Correction: v_off_ini = 936.739 uV, v_off_fin = 932.517 uV 13:52:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.081 uVs 13:52:53 Integrated Voltage Measurement... 13:53:02 Voltage Offset Correction: v_off_ini = 930.307 uV, v_off_fin = 935.598 uV 13:53:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.929 uVs 13:53:02 Integrated Voltage Measurement... 13:53:11 Voltage Offset Correction: v_off_ini = 929.995 uV, v_off_fin = 935.485 uV 13:53:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.592 uVs 13:53:11 Integrated Voltage Measurement... 13:53:20 Voltage Offset Correction: v_off_ini = 913.755 uV, v_off_fin = 922.997 uV 13:53:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.972 uVs 13:53:22 I2X Average and RMS of Measurements VT = -109.304 +- 12.605 uVs I2X = 10.056 +- 1.160 uTm^2 13:53:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:53:30 Integrated Voltage Measurement... 13:53:39 Voltage Offset Correction: v_off_ini = 905.453 uV, v_off_fin = 905.265 uV 13:53:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.686 uVs 13:53:39 Integrated Voltage Measurement... 13:53:48 Voltage Offset Correction: v_off_ini = 916.893 uV, v_off_fin = 926.281 uV 13:53:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.440 uVs 13:53:48 Integrated Voltage Measurement... 13:53:57 Voltage Offset Correction: v_off_ini = 918.512 uV, v_off_fin = 935.484 uV 13:53:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.730 uVs 13:53:57 Integrated Voltage Measurement... 13:54:06 Voltage Offset Correction: v_off_ini = 938.024 uV, v_off_fin = 935.070 uV 13:54:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.776 uVs 13:54:06 Integrated Voltage Measurement... 13:54:15 Voltage Offset Correction: v_off_ini = 937.871 uV, v_off_fin = 927.335 uV 13:54:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.939 uVs 13:54:15 Integrated Voltage Measurement... 13:54:24 Voltage Offset Correction: v_off_ini = 921.515 uV, v_off_fin = 919.570 uV 13:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.881 uVs 13:54:27 I2Y Average and RMS of Measurements VT = -245.742 +- 5.072 uVs I2Y = -22.608 +- 0.467 uTm^2 13:54:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:54:39 Integrated Voltage Measurement... 13:54:48 Voltage Offset Correction: v_off_ini = 909.934 uV, v_off_fin = 919.131 uV 13:54:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.595 uVs 13:54:48 Integrated Voltage Measurement... 13:54:57 Voltage Offset Correction: v_off_ini = 921.549 uV, v_off_fin = 930.417 uV 13:54:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.784 uVs 13:54:57 Integrated Voltage Measurement... 13:55:06 Voltage Offset Correction: v_off_ini = 925.152 uV, v_off_fin = 924.439 uV 13:55:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.373 uVs 13:55:06 Integrated Voltage Measurement... 13:55:15 Voltage Offset Correction: v_off_ini = 920.034 uV, v_off_fin = 925.243 uV 13:55:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.623 uVs 13:55:15 Integrated Voltage Measurement... 13:55:24 Voltage Offset Correction: v_off_ini = 910.470 uV, v_off_fin = 920.765 uV 13:55:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.321 uVs 13:55:24 Integrated Voltage Measurement... 13:55:33 Voltage Offset Correction: v_off_ini = 925.082 uV, v_off_fin = 928.226 uV 13:55:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.746 uVs 13:55:37 I1X Average and RMS of Measurements VT = -103.740 +- 9.133 uVs I1X = 20.748 +- 1.827 uTm 13:55:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:55:44 Integrated Voltage Measurement... 13:55:53 Voltage Offset Correction: v_off_ini = 917.933 uV, v_off_fin = 901.013 uV 13:55:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.328 uVs 13:55:53 Integrated Voltage Measurement... 13:56:02 Voltage Offset Correction: v_off_ini = 921.066 uV, v_off_fin = 929.689 uV 13:56:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.872 uVs 13:56:02 Integrated Voltage Measurement... 13:56:11 Voltage Offset Correction: v_off_ini = 922.420 uV, v_off_fin = 916.368 uV 13:56:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.017 uVs 13:56:11 Integrated Voltage Measurement... 13:56:20 Voltage Offset Correction: v_off_ini = 916.484 uV, v_off_fin = 928.953 uV 13:56:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.001 uVs 13:56:20 Integrated Voltage Measurement... 13:56:29 Voltage Offset Correction: v_off_ini = 934.477 uV, v_off_fin = 932.063 uV 13:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.393 uVs 13:56:29 Integrated Voltage Measurement... 13:56:38 Voltage Offset Correction: v_off_ini = 953.363 uV, v_off_fin = 950.380 uV 13:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.988 uVs 13:56:42 I1Y Average and RMS of Measurements VT = -233.767 +- 2.714 uVs I1Y = -46.753 +- 0.543 uTm 13:56:45 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:56:47 Integrated Voltage Measurement... 13:56:56 Voltage Offset Correction: v_off_ini = 936.347 uV, v_off_fin = 910.522 uV 13:56:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -117.161 uVs 13:56:56 Integrated Voltage Measurement... 13:57:05 Voltage Offset Correction: v_off_ini = 927.496 uV, v_off_fin = 933.667 uV 13:57:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.888 uVs 13:57:05 Integrated Voltage Measurement... 13:57:14 Voltage Offset Correction: v_off_ini = 929.833 uV, v_off_fin = 928.263 uV 13:57:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.001 uVs 13:57:14 Integrated Voltage Measurement... 13:57:23 Voltage Offset Correction: v_off_ini = 923.086 uV, v_off_fin = 920.954 uV 13:57:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.281 uVs 13:57:23 Integrated Voltage Measurement... 13:57:32 Voltage Offset Correction: v_off_ini = 920.642 uV, v_off_fin = 920.120 uV 13:57:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.159 uVs 13:57:32 Integrated Voltage Measurement... 13:57:41 Voltage Offset Correction: v_off_ini = 924.663 uV, v_off_fin = 916.837 uV 13:57:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.861 uVs 13:57:44 I2X Average and RMS of Measurements VT = -124.392 +- 6.594 uVs I2X = 11.444 +- 0.607 uTm^2 13:57:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:57:49 Integrated Voltage Measurement... 13:57:58 Voltage Offset Correction: v_off_ini = 919.403 uV, v_off_fin = 919.824 uV 13:57:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -279.968 uVs 13:57:58 Integrated Voltage Measurement... 13:58:07 Voltage Offset Correction: v_off_ini = 915.576 uV, v_off_fin = 906.165 uV 13:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.083 uVs 13:58:07 Integrated Voltage Measurement... 13:58:16 Voltage Offset Correction: v_off_ini = 897.987 uV, v_off_fin = 909.050 uV 13:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.351 uVs 13:58:16 Integrated Voltage Measurement... 13:58:25 Voltage Offset Correction: v_off_ini = 906.387 uV, v_off_fin = 918.276 uV 13:58:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.818 uVs 13:58:25 Integrated Voltage Measurement... 13:58:34 Voltage Offset Correction: v_off_ini = 918.627 uV, v_off_fin = 915.567 uV 13:58:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.075 uVs 13:58:34 Integrated Voltage Measurement... 13:58:43 Voltage Offset Correction: v_off_ini = 900.210 uV, v_off_fin = 901.225 uV 13:58:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.396 uVs 13:58:45 I2Y Average and RMS of Measurements VT = -250.615 +- 14.741 uVs I2Y = -23.057 +- 1.357 uTm^2 13:58:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:58:54 Integrated Voltage Measurement... 13:59:03 Voltage Offset Correction: v_off_ini = 900.314 uV, v_off_fin = 894.281 uV 13:59:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -126.535 uVs 13:59:03 Integrated Voltage Measurement... 13:59:12 Voltage Offset Correction: v_off_ini = 915.743 uV, v_off_fin = 907.092 uV 13:59:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 133.478 uVs 13:59:12 Integrated Voltage Measurement... 13:59:21 Voltage Offset Correction: v_off_ini = 889.784 uV, v_off_fin = 906.617 uV 13:59:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -137.522 uVs 13:59:21 Integrated Voltage Measurement... 13:59:30 Voltage Offset Correction: v_off_ini = 896.213 uV, v_off_fin = 897.013 uV 13:59:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.287 uVs 13:59:30 Integrated Voltage Measurement... 13:59:39 Voltage Offset Correction: v_off_ini = 903.567 uV, v_off_fin = 888.215 uV 13:59:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.195 uVs 13:59:39 Integrated Voltage Measurement... 13:59:48 Voltage Offset Correction: v_off_ini = 878.362 uV, v_off_fin = 887.143 uV 13:59:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.060 uVs 13:59:52 I1X Average and RMS of Measurements VT = -130.513 +- 5.432 uVs I1X = 26.105 +- 1.087 uTm 13:59:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:59:59 Integrated Voltage Measurement... 14:00:08 Voltage Offset Correction: v_off_ini = 878.851 uV, v_off_fin = 871.436 uV 14:00:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.232 uVs 14:00:08 Integrated Voltage Measurement... 14:00:17 Voltage Offset Correction: v_off_ini = 871.239 uV, v_off_fin = 900.546 uV 14:00:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.033 uVs 14:00:17 Integrated Voltage Measurement... 14:00:26 Voltage Offset Correction: v_off_ini = 890.348 uV, v_off_fin = 882.393 uV 14:00:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.841 uVs 14:00:26 Integrated Voltage Measurement... 14:00:35 Voltage Offset Correction: v_off_ini = 878.316 uV, v_off_fin = 889.970 uV 14:00:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.424 uVs 14:00:35 Integrated Voltage Measurement... 14:00:44 Voltage Offset Correction: v_off_ini = 906.172 uV, v_off_fin = 899.548 uV 14:00:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.316 uVs 14:00:44 Integrated Voltage Measurement... 14:00:53 Voltage Offset Correction: v_off_ini = 898.982 uV, v_off_fin = 904.471 uV 14:00:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.449 uVs 14:00:57 I1Y Average and RMS of Measurements VT = -229.216 +- 4.303 uVs I1Y = -45.843 +- 0.861 uTm 14:00:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:01:02 Integrated Voltage Measurement... 14:01:11 Voltage Offset Correction: v_off_ini = 889.162 uV, v_off_fin = 891.595 uV 14:01:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.954 uVs 14:01:11 Integrated Voltage Measurement... 14:01:20 Voltage Offset Correction: v_off_ini = 900.467 uV, v_off_fin = 906.408 uV 14:01:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.853 uVs 14:01:20 Integrated Voltage Measurement... 14:01:29 Voltage Offset Correction: v_off_ini = 884.793 uV, v_off_fin = 896.695 uV 14:01:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.917 uVs 14:01:29 Integrated Voltage Measurement... 14:01:38 Voltage Offset Correction: v_off_ini = 903.385 uV, v_off_fin = 914.258 uV 14:01:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.072 uVs 14:01:38 Integrated Voltage Measurement... 14:01:47 Voltage Offset Correction: v_off_ini = 899.156 uV, v_off_fin = 899.858 uV 14:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.068 uVs 14:01:47 Integrated Voltage Measurement... 14:01:56 Voltage Offset Correction: v_off_ini = 908.089 uV, v_off_fin = 912.398 uV 14:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.369 uVs 14:01:59 I2X Average and RMS of Measurements VT = -128.872 +- 3.957 uVs I2X = 11.856 +- 0.364 uTm^2 14:02:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:02:04 Integrated Voltage Measurement... 14:02:13 Voltage Offset Correction: v_off_ini = 933.604 uV, v_off_fin = 920.151 uV 14:02:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.313 uVs 14:02:13 Integrated Voltage Measurement... 14:02:22 Voltage Offset Correction: v_off_ini = 898.630 uV, v_off_fin = 906.113 uV 14:02:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.783 uVs 14:02:22 Integrated Voltage Measurement... 14:02:31 Voltage Offset Correction: v_off_ini = 896.988 uV, v_off_fin = 895.246 uV 14:02:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.035 uVs 14:02:31 Integrated Voltage Measurement... 14:02:40 Voltage Offset Correction: v_off_ini = 915.121 uV, v_off_fin = 902.757 uV 14:02:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.639 uVs 14:02:40 Integrated Voltage Measurement... 14:02:49 Voltage Offset Correction: v_off_ini = 915.289 uV, v_off_fin = 901.467 uV 14:02:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.692 uVs 14:02:49 Integrated Voltage Measurement... 14:02:58 Voltage Offset Correction: v_off_ini = 898.773 uV, v_off_fin = 909.879 uV 14:02:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.799 uVs 14:03:00 I2Y Average and RMS of Measurements VT = -242.377 +- 9.178 uVs I2Y = -22.299 +- 0.844 uTm^2 14:03:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:03:09 Integrated Voltage Measurement... 14:03:17 Voltage Offset Correction: v_off_ini = 907.393 uV, v_off_fin = 918.065 uV 14:03:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -126.188 uVs 14:03:18 Integrated Voltage Measurement... 14:03:26 Voltage Offset Correction: v_off_ini = 903.141 uV, v_off_fin = 910.203 uV 14:03:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.155 uVs 14:03:27 Integrated Voltage Measurement... 14:03:36 Voltage Offset Correction: v_off_ini = 899.196 uV, v_off_fin = 889.231 uV 14:03:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.079 uVs 14:03:36 Integrated Voltage Measurement... 14:03:44 Voltage Offset Correction: v_off_ini = 908.531 uV, v_off_fin = 902.612 uV 14:03:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.920 uVs 14:03:45 Integrated Voltage Measurement... 14:03:54 Voltage Offset Correction: v_off_ini = 905.253 uV, v_off_fin = 903.689 uV 14:03:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.014 uVs 14:03:54 Integrated Voltage Measurement... 14:04:03 Voltage Offset Correction: v_off_ini = 893.274 uV, v_off_fin = 908.459 uV 14:04:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.602 uVs 14:04:07 I1X Average and RMS of Measurements VT = -117.660 +- 9.806 uVs I1X = 23.532 +- 1.962 uTm 14:04:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:14 Integrated Voltage Measurement... 14:04:22 Voltage Offset Correction: v_off_ini = 922.885 uV, v_off_fin = 907.471 uV 14:04:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.486 uVs 14:04:23 Integrated Voltage Measurement... 14:04:31 Voltage Offset Correction: v_off_ini = 922.489 uV, v_off_fin = 941.552 uV 14:04:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.323 uVs 14:04:32 Integrated Voltage Measurement... 14:04:40 Voltage Offset Correction: v_off_ini = 908.525 uV, v_off_fin = 908.426 uV 14:04:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.283 uVs 14:04:41 Integrated Voltage Measurement... 14:04:49 Voltage Offset Correction: v_off_ini = 925.947 uV, v_off_fin = 944.443 uV 14:04:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.344 uVs 14:04:49 Integrated Voltage Measurement... 14:04:58 Voltage Offset Correction: v_off_ini = 932.284 uV, v_off_fin = 905.640 uV 14:04:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.613 uVs 14:04:58 Integrated Voltage Measurement... 14:05:07 Voltage Offset Correction: v_off_ini = 905.099 uV, v_off_fin = 919.681 uV 14:05:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 232.626 uVs 14:05:12 I1Y Average and RMS of Measurements VT = -233.946 +- 7.693 uVs I1Y = -46.788 +- 1.539 uTm 14:05:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:17 Integrated Voltage Measurement... 14:05:26 Voltage Offset Correction: v_off_ini = 923.970 uV, v_off_fin = 910.483 uV 14:05:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.086 uVs 14:05:26 Integrated Voltage Measurement... 14:05:35 Voltage Offset Correction: v_off_ini = 932.764 uV, v_off_fin = 931.817 uV 14:05:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.242 uVs 14:05:35 Integrated Voltage Measurement... 14:05:44 Voltage Offset Correction: v_off_ini = 924.376 uV, v_off_fin = 927.451 uV 14:05:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.504 uVs 14:05:44 Integrated Voltage Measurement... 14:05:53 Voltage Offset Correction: v_off_ini = 929.997 uV, v_off_fin = 933.407 uV 14:05:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.487 uVs 14:05:53 Integrated Voltage Measurement... 14:06:02 Voltage Offset Correction: v_off_ini = 922.869 uV, v_off_fin = 937.204 uV 14:06:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.609 uVs 14:06:02 Integrated Voltage Measurement... 14:06:11 Voltage Offset Correction: v_off_ini = 933.871 uV, v_off_fin = 945.158 uV 14:06:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.712 uVs 14:06:13 I2X Average and RMS of Measurements VT = -128.607 +- 2.867 uVs I2X = 11.832 +- 0.264 uTm^2 14:06:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:18 Integrated Voltage Measurement... 14:06:27 Voltage Offset Correction: v_off_ini = 936.908 uV, v_off_fin = 938.723 uV 14:06:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.025 uVs 14:06:27 Integrated Voltage Measurement... 14:06:36 Voltage Offset Correction: v_off_ini = 932.485 uV, v_off_fin = 940.461 uV 14:06:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.624 uVs 14:06:36 Integrated Voltage Measurement... 14:06:45 Voltage Offset Correction: v_off_ini = 914.112 uV, v_off_fin = 923.960 uV 14:06:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.543 uVs 14:06:46 Integrated Voltage Measurement... 14:06:54 Voltage Offset Correction: v_off_ini = 916.321 uV, v_off_fin = 928.440 uV 14:06:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.975 uVs 14:06:55 Integrated Voltage Measurement... 14:07:04 Voltage Offset Correction: v_off_ini = 931.250 uV, v_off_fin = 926.263 uV 14:07:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.083 uVs 14:07:04 Integrated Voltage Measurement... 14:07:13 Voltage Offset Correction: v_off_ini = 940.406 uV, v_off_fin = 944.936 uV 14:07:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.478 uVs 14:07:15 I2Y Average and RMS of Measurements VT = -237.455 +- 2.894 uVs I2Y = -21.846 +- 0.266 uTm^2 14:07:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:07:23 Integrated Voltage Measurement... 14:07:32 Voltage Offset Correction: v_off_ini = 923.566 uV, v_off_fin = 921.663 uV 14:07:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.251 uVs 14:07:32 Integrated Voltage Measurement... 14:07:41 Voltage Offset Correction: v_off_ini = 920.551 uV, v_off_fin = 927.459 uV 14:07:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.080 uVs 14:07:41 Integrated Voltage Measurement... 14:07:50 Voltage Offset Correction: v_off_ini = 930.794 uV, v_off_fin = 944.902 uV 14:07:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.194 uVs 14:07:50 Integrated Voltage Measurement... 14:07:59 Voltage Offset Correction: v_off_ini = 946.801 uV, v_off_fin = 930.059 uV 14:07:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.704 uVs 14:07:59 Integrated Voltage Measurement... 14:08:08 Voltage Offset Correction: v_off_ini = 923.136 uV, v_off_fin = 922.045 uV 14:08:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.243 uVs 14:08:08 Integrated Voltage Measurement... 14:08:17 Voltage Offset Correction: v_off_ini = 922.570 uV, v_off_fin = 920.971 uV 14:08:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.977 uVs 14:08:21 I1X Average and RMS of Measurements VT = -117.908 +- 12.130 uVs I1X = 23.582 +- 2.426 uTm 14:08:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:08:28 Integrated Voltage Measurement... 14:08:37 Voltage Offset Correction: v_off_ini = 916.915 uV, v_off_fin = 912.670 uV 14:08:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -217.281 uVs 14:08:37 Integrated Voltage Measurement... 14:08:46 Voltage Offset Correction: v_off_ini = 903.312 uV, v_off_fin = 926.980 uV 14:08:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 220.551 uVs 14:08:46 Integrated Voltage Measurement... 14:08:55 Voltage Offset Correction: v_off_ini = 917.252 uV, v_off_fin = 910.063 uV 14:08:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.283 uVs 14:08:55 Integrated Voltage Measurement... 14:09:04 Voltage Offset Correction: v_off_ini = 929.802 uV, v_off_fin = 948.688 uV 14:09:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.501 uVs 14:09:04 Integrated Voltage Measurement... 14:09:13 Voltage Offset Correction: v_off_ini = 927.599 uV, v_off_fin = 932.017 uV 14:09:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.273 uVs 14:09:13 Integrated Voltage Measurement... 14:09:22 Voltage Offset Correction: v_off_ini = 920.603 uV, v_off_fin = 924.407 uV 14:09:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.711 uVs 14:09:26 I1Y Average and RMS of Measurements VT = -220.933 +- 7.125 uVs I1Y = -44.187 +- 1.426 uTm 14:09:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:09:31 Integrated Voltage Measurement... 14:09:40 Voltage Offset Correction: v_off_ini = 933.231 uV, v_off_fin = 930.270 uV 14:09:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.348 uVs 14:09:41 Integrated Voltage Measurement... 14:09:49 Voltage Offset Correction: v_off_ini = 923.308 uV, v_off_fin = 936.619 uV 14:09:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.131 uVs 14:09:50 Integrated Voltage Measurement... 14:09:59 Voltage Offset Correction: v_off_ini = 926.644 uV, v_off_fin = 903.466 uV 14:09:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.883 uVs 14:09:59 Integrated Voltage Measurement... 14:10:08 Voltage Offset Correction: v_off_ini = 929.056 uV, v_off_fin = 924.991 uV 14:10:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.957 uVs 14:10:08 Integrated Voltage Measurement... 14:10:17 Voltage Offset Correction: v_off_ini = 917.451 uV, v_off_fin = 911.850 uV 14:10:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.221 uVs 14:10:17 Integrated Voltage Measurement... 14:10:26 Voltage Offset Correction: v_off_ini = 936.620 uV, v_off_fin = 946.497 uV 14:10:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.574 uVs 14:10:28 I2X Average and RMS of Measurements VT = -119.352 +- 6.932 uVs I2X = 10.980 +- 0.638 uTm^2 14:10:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:10:33 Integrated Voltage Measurement... 14:10:42 Voltage Offset Correction: v_off_ini = 923.914 uV, v_off_fin = 904.798 uV 14:10:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.467 uVs 14:10:42 Integrated Voltage Measurement... 14:10:51 Voltage Offset Correction: v_off_ini = 898.348 uV, v_off_fin = 916.647 uV 14:10:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.985 uVs 14:10:51 Integrated Voltage Measurement... 14:11:00 Voltage Offset Correction: v_off_ini = 937.742 uV, v_off_fin = 921.824 uV 14:11:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.140 uVs 14:11:00 Integrated Voltage Measurement... 14:11:09 Voltage Offset Correction: v_off_ini = 909.539 uV, v_off_fin = 918.636 uV 14:11:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.171 uVs 14:11:09 Integrated Voltage Measurement... 14:11:18 Voltage Offset Correction: v_off_ini = 921.820 uV, v_off_fin = 916.881 uV 14:11:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.440 uVs 14:11:18 Integrated Voltage Measurement... 14:11:27 Voltage Offset Correction: v_off_ini = 928.607 uV, v_off_fin = 921.917 uV 14:11:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.411 uVs 14:11:30 I2Y Average and RMS of Measurements VT = -235.269 +- 2.968 uVs I2Y = -21.645 +- 0.273 uTm^2 14:11:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:11:38 Integrated Voltage Measurement... 14:11:47 Voltage Offset Correction: v_off_ini = 951.374 uV, v_off_fin = 943.141 uV 14:11:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -110.649 uVs 14:11:47 Integrated Voltage Measurement... 14:11:56 Voltage Offset Correction: v_off_ini = 935.323 uV, v_off_fin = 950.113 uV 14:11:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.476 uVs 14:11:56 Integrated Voltage Measurement... 14:12:05 Voltage Offset Correction: v_off_ini = 946.952 uV, v_off_fin = 949.383 uV 14:12:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.407 uVs 14:12:05 Integrated Voltage Measurement... 14:12:14 Voltage Offset Correction: v_off_ini = 945.933 uV, v_off_fin = 929.271 uV 14:12:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.613 uVs 14:12:14 Integrated Voltage Measurement... 14:12:23 Voltage Offset Correction: v_off_ini = 942.888 uV, v_off_fin = 937.991 uV 14:12:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.320 uVs 14:12:23 Integrated Voltage Measurement... 14:12:32 Voltage Offset Correction: v_off_ini = 940.762 uV, v_off_fin = 936.790 uV 14:12:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.945 uVs 14:12:36 I1X Average and RMS of Measurements VT = -116.402 +- 7.351 uVs I1X = 23.281 +- 1.470 uTm 14:12:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:12:43 Integrated Voltage Measurement... 14:12:52 Voltage Offset Correction: v_off_ini = 946.480 uV, v_off_fin = 952.200 uV 14:12:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -224.392 uVs 14:12:52 Integrated Voltage Measurement... 14:13:01 Voltage Offset Correction: v_off_ini = 944.674 uV, v_off_fin = 962.013 uV 14:13:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.721 uVs 14:13:01 Integrated Voltage Measurement... 14:13:10 Voltage Offset Correction: v_off_ini = 944.872 uV, v_off_fin = 934.271 uV 14:13:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.783 uVs 14:13:10 Integrated Voltage Measurement... 14:13:19 Voltage Offset Correction: v_off_ini = 944.720 uV, v_off_fin = 956.117 uV 14:13:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.965 uVs 14:13:19 Integrated Voltage Measurement... 14:13:28 Voltage Offset Correction: v_off_ini = 963.573 uV, v_off_fin = 957.449 uV 14:13:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.885 uVs 14:13:28 Integrated Voltage Measurement... 14:13:37 Voltage Offset Correction: v_off_ini = 953.522 uV, v_off_fin = 951.447 uV 14:13:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.769 uVs 14:13:41 I1Y Average and RMS of Measurements VT = -226.086 +- 1.657 uVs I1Y = -45.215 +- 0.331 uTm 14:13:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:13:46 Integrated Voltage Measurement... 14:13:55 Voltage Offset Correction: v_off_ini = 940.042 uV, v_off_fin = 940.518 uV 14:13:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -93.134 uVs 14:13:55 Integrated Voltage Measurement... 14:14:04 Voltage Offset Correction: v_off_ini = 962.451 uV, v_off_fin = 976.414 uV 14:14:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.181 uVs 14:14:04 Integrated Voltage Measurement... 14:14:13 Voltage Offset Correction: v_off_ini = 953.107 uV, v_off_fin = 943.997 uV 14:14:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.253 uVs 14:14:13 Integrated Voltage Measurement... 14:14:22 Voltage Offset Correction: v_off_ini = 971.744 uV, v_off_fin = 982.742 uV 14:14:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.072 uVs 14:14:22 Integrated Voltage Measurement... 14:14:31 Voltage Offset Correction: v_off_ini = 964.417 uV, v_off_fin = 942.531 uV 14:14:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.376 uVs 14:14:31 Integrated Voltage Measurement... 14:14:40 Voltage Offset Correction: v_off_ini = 929.092 uV, v_off_fin = 958.315 uV 14:14:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.016 uVs 14:14:43 I2X Average and RMS of Measurements VT = -104.006 +- 12.272 uVs I2X = 9.568 +- 1.129 uTm^2 14:14:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:14:48 Integrated Voltage Measurement... 14:14:57 Voltage Offset Correction: v_off_ini = 944.726 uV, v_off_fin = 938.450 uV 14:14:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.514 uVs 14:14:57 Integrated Voltage Measurement... 14:15:06 Voltage Offset Correction: v_off_ini = 956.175 uV, v_off_fin = 938.581 uV 14:15:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.904 uVs 14:15:06 Integrated Voltage Measurement... 14:15:15 Voltage Offset Correction: v_off_ini = 944.833 uV, v_off_fin = 935.399 uV 14:15:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.795 uVs 14:15:15 Integrated Voltage Measurement... 14:15:24 Voltage Offset Correction: v_off_ini = 933.825 uV, v_off_fin = 938.869 uV 14:15:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.390 uVs 14:15:24 Integrated Voltage Measurement... 14:15:33 Voltage Offset Correction: v_off_ini = 952.347 uV, v_off_fin = 951.913 uV 14:15:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.821 uVs 14:15:33 Integrated Voltage Measurement... 14:15:42 Voltage Offset Correction: v_off_ini = 935.960 uV, v_off_fin = 939.175 uV 14:15:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 253.236 uVs 14:15:45 I2Y Average and RMS of Measurements VT = -235.277 +- 7.588 uVs I2Y = -21.646 +- 0.699 uTm^2 14:16:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:16:05 Integrated Voltage Measurement... 14:16:14 Voltage Offset Correction: v_off_ini = 942.387 uV, v_off_fin = 925.579 uV 14:16:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -142.938 uVs 14:16:14 Integrated Voltage Measurement... 14:16:23 Voltage Offset Correction: v_off_ini = 945.639 uV, v_off_fin = 942.938 uV 14:16:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.813 uVs 14:16:23 Integrated Voltage Measurement... 14:16:32 Voltage Offset Correction: v_off_ini = 936.504 uV, v_off_fin = 929.831 uV 14:16:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -155.148 uVs 14:16:32 Integrated Voltage Measurement... 14:16:41 Voltage Offset Correction: v_off_ini = 929.862 uV, v_off_fin = 939.076 uV 14:16:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.429 uVs 14:16:41 Integrated Voltage Measurement... 14:16:50 Voltage Offset Correction: v_off_ini = 935.291 uV, v_off_fin = 944.998 uV 14:16:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.957 uVs 14:16:50 Integrated Voltage Measurement... 14:16:59 Voltage Offset Correction: v_off_ini = 939.741 uV, v_off_fin = 946.461 uV 14:16:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.549 uVs 14:17:03 I1X Average and RMS of Measurements VT = -139.139 +- 8.438 uVs I1X = 27.829 +- 1.687 uTm 14:17:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:17:10 Integrated Voltage Measurement... 14:17:19 Voltage Offset Correction: v_off_ini = 938.361 uV, v_off_fin = 946.198 uV 14:17:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -228.454 uVs 14:17:19 Integrated Voltage Measurement... 14:17:28 Voltage Offset Correction: v_off_ini = 955.667 uV, v_off_fin = 964.504 uV 14:17:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.206 uVs 14:17:28 Integrated Voltage Measurement... 14:17:37 Voltage Offset Correction: v_off_ini = 950.942 uV, v_off_fin = 937.795 uV 14:17:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.630 uVs 14:17:37 Integrated Voltage Measurement... 14:17:46 Voltage Offset Correction: v_off_ini = 940.932 uV, v_off_fin = 954.879 uV 14:17:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.356 uVs 14:17:46 Integrated Voltage Measurement... 14:17:55 Voltage Offset Correction: v_off_ini = 928.325 uV, v_off_fin = 916.494 uV 14:17:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.657 uVs 14:17:55 Integrated Voltage Measurement... 14:18:04 Voltage Offset Correction: v_off_ini = 935.853 uV, v_off_fin = 950.405 uV 14:18:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.478 uVs 14:18:08 I1Y Average and RMS of Measurements VT = -221.963 +- 4.222 uVs I1Y = -44.394 +- 0.847 uTm 14:18:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:18:16 Integrated Voltage Measurement... 14:18:25 Voltage Offset Correction: v_off_ini = 938.805 uV, v_off_fin = 944.590 uV 14:18:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -157.330 uVs 14:18:25 Integrated Voltage Measurement... 14:18:34 Voltage Offset Correction: v_off_ini = 959.681 uV, v_off_fin = 977.235 uV 14:18:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.040 uVs 14:18:34 Integrated Voltage Measurement... 14:18:43 Voltage Offset Correction: v_off_ini = 969.517 uV, v_off_fin = 942.596 uV 14:18:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.266 uVs 14:18:43 Integrated Voltage Measurement... 14:18:52 Voltage Offset Correction: v_off_ini = 947.311 uV, v_off_fin = 954.793 uV 14:18:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.905 uVs 14:18:52 Integrated Voltage Measurement... 14:19:01 Voltage Offset Correction: v_off_ini = 950.664 uV, v_off_fin = 934.314 uV 14:19:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.867 uVs 14:19:01 Integrated Voltage Measurement... 14:19:10 Voltage Offset Correction: v_off_ini = 935.839 uV, v_off_fin = 956.748 uV 14:19:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.618 uVs 14:19:12 I2X Average and RMS of Measurements VT = -137.004 +- 10.588 uVs I2X = 12.604 +- 0.974 uTm^2 14:19:17 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:19:20 Integrated Voltage Measurement... 14:19:29 Voltage Offset Correction: v_off_ini = 964.133 uV, v_off_fin = 947.053 uV 14:19:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.785 uVs 14:19:29 Integrated Voltage Measurement... 14:19:38 Voltage Offset Correction: v_off_ini = 945.350 uV, v_off_fin = 935.312 uV 14:19:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.476 uVs 14:19:38 Integrated Voltage Measurement... 14:19:47 Voltage Offset Correction: v_off_ini = 954.780 uV, v_off_fin = 962.074 uV 14:19:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.556 uVs 14:19:47 Integrated Voltage Measurement... 14:19:56 Voltage Offset Correction: v_off_ini = 962.678 uV, v_off_fin = 964.488 uV 14:19:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.205 uVs 14:19:56 Integrated Voltage Measurement... 14:20:05 Voltage Offset Correction: v_off_ini = 941.499 uV, v_off_fin = 917.778 uV 14:20:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.057 uVs 14:20:05 Integrated Voltage Measurement... 14:20:14 Voltage Offset Correction: v_off_ini = 931.613 uV, v_off_fin = 952.574 uV 14:20:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.764 uVs 14:20:17 I2Y Average and RMS of Measurements VT = -240.807 +- 5.620 uVs I2Y = -22.154 +- 0.517 uTm^2 14:20:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:20:26 Integrated Voltage Measurement... 14:20:34 Voltage Offset Correction: v_off_ini = 937.251 uV, v_off_fin = 932.858 uV 14:20:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.773 uVs 14:20:35 Integrated Voltage Measurement... 14:20:44 Voltage Offset Correction: v_off_ini = 916.368 uV, v_off_fin = 935.114 uV 14:20:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.434 uVs 14:20:44 Integrated Voltage Measurement... 14:20:53 Voltage Offset Correction: v_off_ini = 935.170 uV, v_off_fin = 939.490 uV 14:20:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.935 uVs 14:20:53 Integrated Voltage Measurement... 14:21:02 Voltage Offset Correction: v_off_ini = 929.476 uV, v_off_fin = 931.842 uV 14:21:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.043 uVs 14:21:02 Integrated Voltage Measurement... 14:21:11 Voltage Offset Correction: v_off_ini = 933.299 uV, v_off_fin = 935.779 uV 14:21:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.992 uVs 14:21:11 Integrated Voltage Measurement... 14:21:20 Voltage Offset Correction: v_off_ini = 936.448 uV, v_off_fin = 941.481 uV 14:21:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 158.403 uVs 14:21:24 I1X Average and RMS of Measurements VT = -139.930 +- 3.540 uVs I1X = 27.987 +- 0.709 uTm 14:21:26 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:21:31 Integrated Voltage Measurement... 14:21:39 Voltage Offset Correction: v_off_ini = 970.867 uV, v_off_fin = 956.339 uV 14:21:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.767 uVs 14:21:40 Integrated Voltage Measurement... 14:21:48 Voltage Offset Correction: v_off_ini = 971.091 uV, v_off_fin = 977.212 uV 14:21:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.280 uVs 14:21:49 Integrated Voltage Measurement... 14:21:57 Voltage Offset Correction: v_off_ini = 948.046 uV, v_off_fin = 931.053 uV 14:21:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -221.946 uVs 14:21:58 Integrated Voltage Measurement... 14:22:06 Voltage Offset Correction: v_off_ini = 954.572 uV, v_off_fin = 966.558 uV 14:22:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.259 uVs 14:22:07 Integrated Voltage Measurement... 14:22:15 Voltage Offset Correction: v_off_ini = 958.374 uV, v_off_fin = 951.855 uV 14:22:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.866 uVs 14:22:16 Integrated Voltage Measurement... 14:22:24 Voltage Offset Correction: v_off_ini = 968.542 uV, v_off_fin = 957.131 uV 14:22:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.355 uVs 14:22:29 I1Y Average and RMS of Measurements VT = -223.912 +- 5.179 uVs I1Y = -44.783 +- 1.037 uTm 14:22:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:22:36 Integrated Voltage Measurement... 14:22:45 Voltage Offset Correction: v_off_ini = 960.207 uV, v_off_fin = 956.934 uV 14:22:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.430 uVs 14:22:45 Integrated Voltage Measurement... 14:22:54 Voltage Offset Correction: v_off_ini = 953.121 uV, v_off_fin = 959.176 uV 14:22:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.690 uVs 14:22:54 Integrated Voltage Measurement... 14:23:03 Voltage Offset Correction: v_off_ini = 952.287 uV, v_off_fin = 943.157 uV 14:23:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.724 uVs 14:23:04 Integrated Voltage Measurement... 14:23:13 Voltage Offset Correction: v_off_ini = 938.733 uV, v_off_fin = 962.743 uV 14:23:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.155 uVs 14:23:13 Integrated Voltage Measurement... 14:23:22 Voltage Offset Correction: v_off_ini = 944.431 uV, v_off_fin = 943.877 uV 14:23:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.143 uVs 14:23:22 Integrated Voltage Measurement... 14:23:31 Voltage Offset Correction: v_off_ini = 956.691 uV, v_off_fin = 961.893 uV 14:23:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.085 uVs 14:23:33 I2X Average and RMS of Measurements VT = -136.538 +- 6.678 uVs I2X = 12.561 +- 0.614 uTm^2 14:23:38 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:23:41 Integrated Voltage Measurement... 14:23:50 Voltage Offset Correction: v_off_ini = 967.495 uV, v_off_fin = 961.083 uV 14:23:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.764 uVs 14:23:50 Integrated Voltage Measurement... 14:23:59 Voltage Offset Correction: v_off_ini = 961.519 uV, v_off_fin = 966.555 uV 14:23:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.662 uVs 14:23:59 Integrated Voltage Measurement... 14:24:08 Voltage Offset Correction: v_off_ini = 950.859 uV, v_off_fin = 963.532 uV 14:24:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.292 uVs 14:24:08 Integrated Voltage Measurement... 14:24:17 Voltage Offset Correction: v_off_ini = 968.619 uV, v_off_fin = 961.650 uV 14:24:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.387 uVs 14:24:17 Integrated Voltage Measurement... 14:24:26 Voltage Offset Correction: v_off_ini = 960.083 uV, v_off_fin = 963.626 uV 14:24:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.561 uVs 14:24:26 Integrated Voltage Measurement... 14:24:35 Voltage Offset Correction: v_off_ini = 962.567 uV, v_off_fin = 965.764 uV 14:24:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.370 uVs 14:24:37 I2Y Average and RMS of Measurements VT = -237.006 +- 9.148 uVs I2Y = -21.805 +- 0.842 uTm^2 14:24:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:24:46 Integrated Voltage Measurement... 14:24:55 Voltage Offset Correction: v_off_ini = 973.989 uV, v_off_fin = 947.260 uV 14:24:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.999 uVs 14:24:55 Integrated Voltage Measurement... 14:25:04 Voltage Offset Correction: v_off_ini = 955.868 uV, v_off_fin = 962.577 uV 14:25:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.850 uVs 14:25:04 Integrated Voltage Measurement... 14:25:13 Voltage Offset Correction: v_off_ini = 961.333 uV, v_off_fin = 947.433 uV 14:25:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.668 uVs 14:25:13 Integrated Voltage Measurement... 14:25:22 Voltage Offset Correction: v_off_ini = 961.668 uV, v_off_fin = 941.121 uV 14:25:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.990 uVs 14:25:22 Integrated Voltage Measurement... 14:25:31 Voltage Offset Correction: v_off_ini = 961.612 uV, v_off_fin = 960.815 uV 14:25:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.126 uVs 14:25:31 Integrated Voltage Measurement... 14:25:40 Voltage Offset Correction: v_off_ini = 961.549 uV, v_off_fin = 948.351 uV 14:25:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.387 uVs 14:25:45 I1X Average and RMS of Measurements VT = -131.670 +- 6.253 uVs I1X = 26.334 +- 1.251 uTm 14:25:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:25:51 Integrated Voltage Measurement... 14:26:00 Voltage Offset Correction: v_off_ini = 961.835 uV, v_off_fin = 963.830 uV 14:26:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.697 uVs 14:26:00 Integrated Voltage Measurement... 14:26:09 Voltage Offset Correction: v_off_ini = 964.639 uV, v_off_fin = 980.523 uV 14:26:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.587 uVs 14:26:10 Integrated Voltage Measurement... 14:26:18 Voltage Offset Correction: v_off_ini = 967.784 uV, v_off_fin = 966.663 uV 14:26:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.852 uVs 14:26:19 Integrated Voltage Measurement... 14:26:27 Voltage Offset Correction: v_off_ini = 977.720 uV, v_off_fin = 979.078 uV 14:26:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.125 uVs 14:26:28 Integrated Voltage Measurement... 14:26:36 Voltage Offset Correction: v_off_ini = 975.585 uV, v_off_fin = 958.304 uV 14:26:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.616 uVs 14:26:37 Integrated Voltage Measurement... 14:26:45 Voltage Offset Correction: v_off_ini = 952.588 uV, v_off_fin = 968.501 uV 14:26:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.902 uVs 14:26:50 I1Y Average and RMS of Measurements VT = -229.796 +- 3.317 uVs I1Y = -45.959 +- 0.663 uTm 14:26:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:57 Integrated Voltage Measurement... 14:27:06 Voltage Offset Correction: v_off_ini = 986.227 uV, v_off_fin = 975.659 uV 14:27:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.184 uVs 14:27:06 Integrated Voltage Measurement... 14:27:15 Voltage Offset Correction: v_off_ini = 978.088 uV, v_off_fin = 976.338 uV 14:27:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.543 uVs 14:27:16 Integrated Voltage Measurement... 14:27:24 Voltage Offset Correction: v_off_ini = 967.315 uV, v_off_fin = 947.338 uV 14:27:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.700 uVs 14:27:25 Integrated Voltage Measurement... 14:27:34 Voltage Offset Correction: v_off_ini = 969.631 uV, v_off_fin = 992.202 uV 14:27:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.720 uVs 14:27:34 Integrated Voltage Measurement... 14:27:43 Voltage Offset Correction: v_off_ini = 966.862 uV, v_off_fin = 975.135 uV 14:27:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.596 uVs 14:27:43 Integrated Voltage Measurement... 14:27:52 Voltage Offset Correction: v_off_ini = 984.191 uV, v_off_fin = 990.029 uV 14:27:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.972 uVs 14:27:54 I2X Average and RMS of Measurements VT = -129.119 +- 11.121 uVs I2X = 11.879 +- 1.023 uTm^2 14:27:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:28:02 Integrated Voltage Measurement... 14:28:11 Voltage Offset Correction: v_off_ini = 991.015 uV, v_off_fin = 978.219 uV 14:28:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.411 uVs 14:28:11 Integrated Voltage Measurement... 14:28:20 Voltage Offset Correction: v_off_ini = 985.068 uV, v_off_fin = 998.005 uV 14:28:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.819 uVs 14:28:20 Integrated Voltage Measurement... 14:28:29 Voltage Offset Correction: v_off_ini = 995.817 uV, v_off_fin = 982.698 uV 14:28:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -247.371 uVs 14:28:29 Integrated Voltage Measurement... 14:28:38 Voltage Offset Correction: v_off_ini = 975.901 uV, v_off_fin = 977.508 uV 14:28:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.324 uVs 14:28:38 Integrated Voltage Measurement... 14:28:47 Voltage Offset Correction: v_off_ini = 968.096 uV, v_off_fin = 966.800 uV 14:28:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.666 uVs 14:28:47 Integrated Voltage Measurement... 14:28:56 Voltage Offset Correction: v_off_ini = 985.919 uV, v_off_fin = 987.805 uV 14:28:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.162 uVs 14:28:58 I2Y Average and RMS of Measurements VT = -243.292 +- 5.720 uVs I2Y = -22.383 +- 0.527 uTm^2 14:29:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:29:07 Integrated Voltage Measurement... 14:29:16 Voltage Offset Correction: v_off_ini = 963.455 uV, v_off_fin = 951.910 uV 14:29:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.921 uVs 14:29:16 Integrated Voltage Measurement... 14:29:25 Voltage Offset Correction: v_off_ini = 964.667 uV, v_off_fin = 977.536 uV 14:29:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.995 uVs 14:29:25 Integrated Voltage Measurement... 14:29:34 Voltage Offset Correction: v_off_ini = 976.515 uV, v_off_fin = 976.350 uV 14:29:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.355 uVs 14:29:34 Integrated Voltage Measurement... 14:29:43 Voltage Offset Correction: v_off_ini = 982.372 uV, v_off_fin = 1001.750 uV 14:29:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.358 uVs 14:29:43 Integrated Voltage Measurement... 14:29:52 Voltage Offset Correction: v_off_ini = 960.161 uV, v_off_fin = 964.910 uV 14:29:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.746 uVs 14:29:52 Integrated Voltage Measurement... 14:30:01 Voltage Offset Correction: v_off_ini = 953.896 uV, v_off_fin = 962.881 uV 14:30:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.309 uVs 14:30:06 I1X Average and RMS of Measurements VT = -116.281 +- 10.486 uVs I1X = 23.256 +- 2.097 uTm 14:30:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:30:12 Integrated Voltage Measurement... 14:30:21 Voltage Offset Correction: v_off_ini = 956.569 uV, v_off_fin = 962.569 uV 14:30:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.046 uVs 14:30:21 Integrated Voltage Measurement... 14:30:30 Voltage Offset Correction: v_off_ini = 958.453 uV, v_off_fin = 965.780 uV 14:30:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.709 uVs 14:30:30 Integrated Voltage Measurement... 14:30:39 Voltage Offset Correction: v_off_ini = 982.653 uV, v_off_fin = 959.841 uV 14:30:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.540 uVs 14:30:39 Integrated Voltage Measurement... 14:30:48 Voltage Offset Correction: v_off_ini = 979.210 uV, v_off_fin = 985.648 uV 14:30:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.216 uVs 14:30:49 Integrated Voltage Measurement... 14:30:57 Voltage Offset Correction: v_off_ini = 970.692 uV, v_off_fin = 998.375 uV 14:30:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.691 uVs 14:30:58 Integrated Voltage Measurement... 14:31:06 Voltage Offset Correction: v_off_ini = 987.947 uV, v_off_fin = 1006.340 uV 14:31:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.510 uVs 14:31:11 I1Y Average and RMS of Measurements VT = -228.285 +- 5.891 uVs I1Y = -45.657 +- 1.178 uTm 14:31:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:31:18 Integrated Voltage Measurement... 14:31:27 Voltage Offset Correction: v_off_ini = 989.364 uV, v_off_fin = 973.502 uV 14:31:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -136.027 uVs 14:31:27 Integrated Voltage Measurement... 14:31:36 Voltage Offset Correction: v_off_ini = 995.118 uV, v_off_fin = 1001.751 uV 14:31:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.774 uVs 14:31:36 Integrated Voltage Measurement... 14:31:45 Voltage Offset Correction: v_off_ini = 997.254 uV, v_off_fin = 998.310 uV 14:31:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.236 uVs 14:31:46 Integrated Voltage Measurement... 14:31:55 Voltage Offset Correction: v_off_ini = 1000.596 uV, v_off_fin = 1013.548 uV 14:31:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.127 uVs 14:31:55 Integrated Voltage Measurement... 14:32:04 Voltage Offset Correction: v_off_ini = 1017.457 uV, v_off_fin = 1006.006 uV 14:32:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.799 uVs 14:32:04 Integrated Voltage Measurement... 14:32:13 Voltage Offset Correction: v_off_ini = 1011.884 uV, v_off_fin = 1015.093 uV 14:32:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.620 uVs 14:32:15 I2X Average and RMS of Measurements VT = -132.597 +- 3.369 uVs I2X = 12.199 +- 0.310 uTm^2 14:32:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:32:23 Integrated Voltage Measurement... 14:32:32 Voltage Offset Correction: v_off_ini = 1000.960 uV, v_off_fin = 1014.893 uV 14:32:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.138 uVs 14:32:32 Integrated Voltage Measurement... 14:32:41 Voltage Offset Correction: v_off_ini = 1025.512 uV, v_off_fin = 1018.057 uV 14:32:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.008 uVs 14:32:41 Integrated Voltage Measurement... 14:32:50 Voltage Offset Correction: v_off_ini = 1022.392 uV, v_off_fin = 1031.588 uV 14:32:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.535 uVs 14:32:50 Integrated Voltage Measurement... 14:32:59 Voltage Offset Correction: v_off_ini = 1015.354 uV, v_off_fin = 1025.778 uV 14:32:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.632 uVs 14:32:59 Integrated Voltage Measurement... 14:33:08 Voltage Offset Correction: v_off_ini = 997.254 uV, v_off_fin = 1012.846 uV 14:33:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.370 uVs 14:33:08 Integrated Voltage Measurement... 14:33:17 Voltage Offset Correction: v_off_ini = 1018.975 uV, v_off_fin = 1008.011 uV 14:33:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.592 uVs 14:33:19 I2Y Average and RMS of Measurements VT = -243.879 +- 14.332 uVs I2Y = -22.437 +- 1.319 uTm^2 14:33:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:33:28 Integrated Voltage Measurement... 14:33:37 Voltage Offset Correction: v_off_ini = 992.210 uV, v_off_fin = 990.592 uV 14:33:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.817 uVs 14:33:37 Integrated Voltage Measurement... 14:33:46 Voltage Offset Correction: v_off_ini = 986.457 uV, v_off_fin = 987.341 uV 14:33:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.055 uVs 14:33:46 Integrated Voltage Measurement... 14:33:55 Voltage Offset Correction: v_off_ini = 1001.655 uV, v_off_fin = 1004.765 uV 14:33:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.187 uVs 14:33:55 Integrated Voltage Measurement... 14:34:04 Voltage Offset Correction: v_off_ini = 985.348 uV, v_off_fin = 992.285 uV 14:34:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 121.357 uVs 14:34:04 Integrated Voltage Measurement... 14:34:13 Voltage Offset Correction: v_off_ini = 989.438 uV, v_off_fin = 981.714 uV 14:34:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.330 uVs 14:34:13 Integrated Voltage Measurement... 14:34:22 Voltage Offset Correction: v_off_ini = 991.298 uV, v_off_fin = 1001.146 uV 14:34:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.366 uVs 14:34:27 I1X Average and RMS of Measurements VT = -131.352 +- 4.543 uVs I1X = 26.271 +- 0.909 uTm 14:34:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:34:33 Integrated Voltage Measurement... 14:34:42 Voltage Offset Correction: v_off_ini = 984.912 uV, v_off_fin = 980.264 uV 14:34:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.370 uVs 14:34:42 Integrated Voltage Measurement... 14:34:51 Voltage Offset Correction: v_off_ini = 995.522 uV, v_off_fin = 1003.458 uV 14:34:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.780 uVs 14:34:51 Integrated Voltage Measurement... 14:35:00 Voltage Offset Correction: v_off_ini = 985.286 uV, v_off_fin = 975.194 uV 14:35:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.343 uVs 14:35:00 Integrated Voltage Measurement... 14:35:09 Voltage Offset Correction: v_off_ini = 996.357 uV, v_off_fin = 999.486 uV 14:35:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.609 uVs 14:35:09 Integrated Voltage Measurement... 14:35:18 Voltage Offset Correction: v_off_ini = 989.865 uV, v_off_fin = 983.934 uV 14:35:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.620 uVs 14:35:18 Integrated Voltage Measurement... 14:35:27 Voltage Offset Correction: v_off_ini = 968.854 uV, v_off_fin = 996.455 uV 14:35:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.654 uVs 14:35:32 I1Y Average and RMS of Measurements VT = -227.396 +- 2.090 uVs I1Y = -45.479 +- 0.418 uTm 14:35:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:35:39 Integrated Voltage Measurement... 14:35:48 Voltage Offset Correction: v_off_ini = 1002.830 uV, v_off_fin = 976.746 uV 14:35:48 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -113.318 uVs 14:35:48 Integrated Voltage Measurement... 14:35:57 Voltage Offset Correction: v_off_ini = 998.224 uV, v_off_fin = 994.931 uV 14:35:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.309 uVs 14:35:57 Integrated Voltage Measurement... 14:36:06 Voltage Offset Correction: v_off_ini = 999.767 uV, v_off_fin = 989.701 uV 14:36:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.976 uVs 14:36:06 Integrated Voltage Measurement... 14:36:15 Voltage Offset Correction: v_off_ini = 991.701 uV, v_off_fin = 1002.587 uV 14:36:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.377 uVs 14:36:16 Integrated Voltage Measurement... 14:36:25 Voltage Offset Correction: v_off_ini = 967.436 uV, v_off_fin = 1010.521 uV 14:36:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.726 uVs 14:36:25 Integrated Voltage Measurement... 14:36:34 Voltage Offset Correction: v_off_ini = 1023.171 uV, v_off_fin = 1019.204 uV 14:36:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.048 uVs 14:36:36 I2X Average and RMS of Measurements VT = -121.626 +- 4.321 uVs I2X = 11.189 +- 0.397 uTm^2 14:36:41 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:36:44 Integrated Voltage Measurement... 14:36:53 Voltage Offset Correction: v_off_ini = 990.085 uV, v_off_fin = 993.440 uV 14:36:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.514 uVs 14:36:53 Integrated Voltage Measurement... 14:37:02 Voltage Offset Correction: v_off_ini = 988.502 uV, v_off_fin = 1005.636 uV 14:37:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.058 uVs 14:37:02 Integrated Voltage Measurement... 14:37:11 Voltage Offset Correction: v_off_ini = 1001.080 uV, v_off_fin = 1002.622 uV 14:37:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.148 uVs 14:37:11 Integrated Voltage Measurement... 14:37:20 Voltage Offset Correction: v_off_ini = 1003.519 uV, v_off_fin = 1009.357 uV 14:37:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.241 uVs 14:37:20 Integrated Voltage Measurement... 14:37:29 Voltage Offset Correction: v_off_ini = 1012.002 uV, v_off_fin = 994.831 uV 14:37:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.395 uVs 14:37:29 Integrated Voltage Measurement... 14:37:38 Voltage Offset Correction: v_off_ini = 995.372 uV, v_off_fin = 1019.085 uV 14:37:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.088 uVs 14:37:40 I2Y Average and RMS of Measurements VT = -242.074 +- 5.698 uVs I2Y = -22.271 +- 0.524 uTm^2 14:37:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:37:52 Integrated Voltage Measurement... 14:38:01 Voltage Offset Correction: v_off_ini = 1010.910 uV, v_off_fin = 1008.100 uV 14:38:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -121.258 uVs 14:38:01 Integrated Voltage Measurement... 14:38:10 Voltage Offset Correction: v_off_ini = 996.977 uV, v_off_fin = 991.275 uV 14:38:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.829 uVs 14:38:10 Integrated Voltage Measurement... 14:38:19 Voltage Offset Correction: v_off_ini = 994.949 uV, v_off_fin = 978.993 uV 14:38:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.572 uVs 14:38:19 Integrated Voltage Measurement... 14:38:28 Voltage Offset Correction: v_off_ini = 966.617 uV, v_off_fin = 983.812 uV 14:38:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.288 uVs 14:38:28 Integrated Voltage Measurement... 14:38:37 Voltage Offset Correction: v_off_ini = 976.364 uV, v_off_fin = 983.328 uV 14:38:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.138 uVs 14:38:37 Integrated Voltage Measurement... 14:38:46 Voltage Offset Correction: v_off_ini = 971.230 uV, v_off_fin = 959.415 uV 14:38:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.756 uVs 14:38:51 I1X Average and RMS of Measurements VT = -123.807 +- 4.528 uVs I1X = 24.762 +- 0.906 uTm 14:38:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:38:57 Integrated Voltage Measurement... 14:39:06 Voltage Offset Correction: v_off_ini = 971.352 uV, v_off_fin = 962.161 uV 14:39:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.671 uVs 14:39:06 Integrated Voltage Measurement... 14:39:15 Voltage Offset Correction: v_off_ini = 985.780 uV, v_off_fin = 976.282 uV 14:39:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.926 uVs 14:39:16 Integrated Voltage Measurement... 14:39:24 Voltage Offset Correction: v_off_ini = 982.088 uV, v_off_fin = 981.760 uV 14:39:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.635 uVs 14:39:25 Integrated Voltage Measurement... 14:39:33 Voltage Offset Correction: v_off_ini = 963.336 uV, v_off_fin = 978.918 uV 14:39:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.169 uVs 14:39:34 Integrated Voltage Measurement... 14:39:42 Voltage Offset Correction: v_off_ini = 982.370 uV, v_off_fin = 981.063 uV 14:39:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.668 uVs 14:39:43 Integrated Voltage Measurement... 14:39:51 Voltage Offset Correction: v_off_ini = 990.531 uV, v_off_fin = 974.081 uV 14:39:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.187 uVs 14:39:56 I1Y Average and RMS of Measurements VT = -232.043 +- 2.841 uVs I1Y = -46.409 +- 0.568 uTm 14:39:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:40:01 Integrated Voltage Measurement... 14:40:10 Voltage Offset Correction: v_off_ini = 983.096 uV, v_off_fin = 989.790 uV 14:40:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.707 uVs 14:40:10 Integrated Voltage Measurement... 14:40:19 Voltage Offset Correction: v_off_ini = 989.223 uV, v_off_fin = 1001.158 uV 14:40:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.625 uVs 14:40:19 Integrated Voltage Measurement... 14:40:28 Voltage Offset Correction: v_off_ini = 1006.953 uV, v_off_fin = 980.548 uV 14:40:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.019 uVs 14:40:28 Integrated Voltage Measurement... 14:40:37 Voltage Offset Correction: v_off_ini = 960.118 uV, v_off_fin = 970.539 uV 14:40:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.454 uVs 14:40:37 Integrated Voltage Measurement... 14:40:46 Voltage Offset Correction: v_off_ini = 970.786 uV, v_off_fin = 958.326 uV 14:40:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.957 uVs 14:40:46 Integrated Voltage Measurement... 14:40:55 Voltage Offset Correction: v_off_ini = 969.225 uV, v_off_fin = 1003.185 uV 14:40:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.424 uVs 14:40:57 I2X Average and RMS of Measurements VT = -140.197 +- 5.780 uVs I2X = 12.898 +- 0.532 uTm^2 14:41:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:41:03 Integrated Voltage Measurement... 14:41:12 Voltage Offset Correction: v_off_ini = 972.140 uV, v_off_fin = 966.959 uV 14:41:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.995 uVs 14:41:12 Integrated Voltage Measurement... 14:41:21 Voltage Offset Correction: v_off_ini = 982.069 uV, v_off_fin = 983.685 uV 14:41:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.290 uVs 14:41:21 Integrated Voltage Measurement... 14:41:30 Voltage Offset Correction: v_off_ini = 981.189 uV, v_off_fin = 970.091 uV 14:41:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.643 uVs 14:41:30 Integrated Voltage Measurement... 14:41:39 Voltage Offset Correction: v_off_ini = 963.602 uV, v_off_fin = 990.993 uV 14:41:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.729 uVs 14:41:39 Integrated Voltage Measurement... 14:41:48 Voltage Offset Correction: v_off_ini = 983.557 uV, v_off_fin = 972.952 uV 14:41:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.594 uVs 14:41:48 Integrated Voltage Measurement... 14:41:57 Voltage Offset Correction: v_off_ini = 951.859 uV, v_off_fin = 959.505 uV 14:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.324 uVs 14:41:59 I2Y Average and RMS of Measurements VT = -235.762 +- 7.378 uVs I2Y = -21.690 +- 0.679 uTm^2 14:42:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:42:08 Integrated Voltage Measurement... 14:42:17 Voltage Offset Correction: v_off_ini = 974.918 uV, v_off_fin = 977.084 uV 14:42:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -131.602 uVs 14:42:17 Integrated Voltage Measurement... 14:42:26 Voltage Offset Correction: v_off_ini = 984.680 uV, v_off_fin = 985.701 uV 14:42:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.526 uVs 14:42:26 Integrated Voltage Measurement... 14:42:35 Voltage Offset Correction: v_off_ini = 977.539 uV, v_off_fin = 1000.846 uV 14:42:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.340 uVs 14:42:35 Integrated Voltage Measurement... 14:42:44 Voltage Offset Correction: v_off_ini = 976.955 uV, v_off_fin = 996.258 uV 14:42:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.988 uVs 14:42:44 Integrated Voltage Measurement... 14:42:53 Voltage Offset Correction: v_off_ini = 1004.875 uV, v_off_fin = 987.432 uV 14:42:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.694 uVs 14:42:53 Integrated Voltage Measurement... 14:43:02 Voltage Offset Correction: v_off_ini = 977.893 uV, v_off_fin = 967.259 uV 14:43:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.740 uVs 14:43:06 I1X Average and RMS of Measurements VT = -124.148 +- 7.950 uVs I1X = 24.831 +- 1.590 uTm 14:43:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:43:13 Integrated Voltage Measurement... 14:43:22 Voltage Offset Correction: v_off_ini = 999.182 uV, v_off_fin = 976.371 uV 14:43:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.615 uVs 14:43:22 Integrated Voltage Measurement... 14:43:31 Voltage Offset Correction: v_off_ini = 1004.783 uV, v_off_fin = 1016.275 uV 14:43:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.614 uVs 14:43:31 Integrated Voltage Measurement... 14:43:40 Voltage Offset Correction: v_off_ini = 992.114 uV, v_off_fin = 990.381 uV 14:43:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.145 uVs 14:43:40 Integrated Voltage Measurement... 14:43:49 Voltage Offset Correction: v_off_ini = 1000.684 uV, v_off_fin = 1018.868 uV 14:43:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.052 uVs 14:43:49 Integrated Voltage Measurement... 14:43:58 Voltage Offset Correction: v_off_ini = 1006.480 uV, v_off_fin = 993.877 uV 14:43:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.417 uVs 14:43:58 Integrated Voltage Measurement... 14:44:07 Voltage Offset Correction: v_off_ini = 1004.913 uV, v_off_fin = 1027.006 uV 14:44:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.642 uVs 14:44:11 I1Y Average and RMS of Measurements VT = -226.081 +- 5.301 uVs I1Y = -45.216 +- 1.060 uTm 14:44:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:44:16 Integrated Voltage Measurement... 14:44:25 Voltage Offset Correction: v_off_ini = 977.686 uV, v_off_fin = 968.953 uV 14:44:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.044 uVs 14:44:25 Integrated Voltage Measurement... 14:44:34 Voltage Offset Correction: v_off_ini = 993.637 uV, v_off_fin = 998.857 uV 14:44:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.850 uVs 14:44:34 Integrated Voltage Measurement... 14:44:43 Voltage Offset Correction: v_off_ini = 981.302 uV, v_off_fin = 989.402 uV 14:44:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.450 uVs 14:44:43 Integrated Voltage Measurement... 14:44:52 Voltage Offset Correction: v_off_ini = 1000.636 uV, v_off_fin = 995.538 uV 14:44:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.620 uVs 14:44:52 Integrated Voltage Measurement... 14:45:01 Voltage Offset Correction: v_off_ini = 980.415 uV, v_off_fin = 976.906 uV 14:45:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.037 uVs 14:45:01 Integrated Voltage Measurement... 14:45:10 Voltage Offset Correction: v_off_ini = 967.953 uV, v_off_fin = 988.520 uV 14:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.064 uVs 14:45:13 I2X Average and RMS of Measurements VT = -138.511 +- 7.426 uVs I2X = 12.743 +- 0.683 uTm^2 14:45:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:45:18 Integrated Voltage Measurement... 14:45:27 Voltage Offset Correction: v_off_ini = 982.852 uV, v_off_fin = 977.680 uV 14:45:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.588 uVs 14:45:27 Integrated Voltage Measurement... 14:45:36 Voltage Offset Correction: v_off_ini = 975.213 uV, v_off_fin = 978.776 uV 14:45:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.753 uVs 14:45:36 Integrated Voltage Measurement... 14:45:45 Voltage Offset Correction: v_off_ini = 981.536 uV, v_off_fin = 975.718 uV 14:45:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.937 uVs 14:45:45 Integrated Voltage Measurement... 14:45:54 Voltage Offset Correction: v_off_ini = 958.019 uV, v_off_fin = 987.951 uV 14:45:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.140 uVs 14:45:54 Integrated Voltage Measurement... 14:46:03 Voltage Offset Correction: v_off_ini = 967.059 uV, v_off_fin = 963.560 uV 14:46:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.201 uVs 14:46:03 Integrated Voltage Measurement... 14:46:12 Voltage Offset Correction: v_off_ini = 951.070 uV, v_off_fin = 956.124 uV 14:46:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.568 uVs 14:46:15 I2Y Average and RMS of Measurements VT = -242.865 +- 6.903 uVs I2Y = -22.344 +- 0.635 uTm^2 14:46:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:23 Integrated Voltage Measurement... 14:46:32 Voltage Offset Correction: v_off_ini = 960.662 uV, v_off_fin = 963.664 uV 14:46:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.885 uVs 14:46:32 Integrated Voltage Measurement... 14:46:41 Voltage Offset Correction: v_off_ini = 968.431 uV, v_off_fin = 968.455 uV 14:46:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 90.781 uVs 14:46:41 Integrated Voltage Measurement... 14:46:50 Voltage Offset Correction: v_off_ini = 980.992 uV, v_off_fin = 987.718 uV 14:46:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.490 uVs 14:46:50 Integrated Voltage Measurement... 14:46:59 Voltage Offset Correction: v_off_ini = 989.041 uV, v_off_fin = 995.627 uV 14:46:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.447 uVs 14:46:59 Integrated Voltage Measurement... 14:47:08 Voltage Offset Correction: v_off_ini = 968.770 uV, v_off_fin = 971.529 uV 14:47:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.063 uVs 14:47:08 Integrated Voltage Measurement... 14:47:17 Voltage Offset Correction: v_off_ini = 965.512 uV, v_off_fin = 973.671 uV 14:47:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 137.666 uVs 14:47:21 I1X Average and RMS of Measurements VT = -113.055 +- 6.909 uVs I1X = 22.612 +- 1.382 uTm 14:47:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:28 Integrated Voltage Measurement... 14:47:37 Voltage Offset Correction: v_off_ini = 977.596 uV, v_off_fin = 976.583 uV 14:47:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.264 uVs 14:47:37 Integrated Voltage Measurement... 14:47:46 Voltage Offset Correction: v_off_ini = 978.769 uV, v_off_fin = 984.233 uV 14:47:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.163 uVs 14:47:46 Integrated Voltage Measurement... 14:47:55 Voltage Offset Correction: v_off_ini = 951.638 uV, v_off_fin = 955.667 uV 14:47:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.679 uVs 14:47:55 Integrated Voltage Measurement... 14:48:04 Voltage Offset Correction: v_off_ini = 947.998 uV, v_off_fin = 970.459 uV 14:48:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.081 uVs 14:48:04 Integrated Voltage Measurement... 14:48:13 Voltage Offset Correction: v_off_ini = 969.911 uV, v_off_fin = 945.985 uV 14:48:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.451 uVs 14:48:13 Integrated Voltage Measurement... 14:48:22 Voltage Offset Correction: v_off_ini = 978.034 uV, v_off_fin = 983.586 uV 14:48:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.967 uVs 14:48:26 I1Y Average and RMS of Measurements VT = -221.934 +- 1.262 uVs I1Y = -44.386 +- 0.250 uTm 14:48:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:31 Integrated Voltage Measurement... 14:48:40 Voltage Offset Correction: v_off_ini = 959.683 uV, v_off_fin = 947.508 uV 14:48:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.995 uVs 14:48:40 Integrated Voltage Measurement... 14:48:49 Voltage Offset Correction: v_off_ini = 965.331 uV, v_off_fin = 965.072 uV 14:48:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.825 uVs 14:48:50 Integrated Voltage Measurement... 14:48:59 Voltage Offset Correction: v_off_ini = 964.675 uV, v_off_fin = 959.296 uV 14:48:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.804 uVs 14:48:59 Integrated Voltage Measurement... 14:49:08 Voltage Offset Correction: v_off_ini = 968.023 uV, v_off_fin = 964.650 uV 14:49:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.097 uVs 14:49:08 Integrated Voltage Measurement... 14:49:17 Voltage Offset Correction: v_off_ini = 944.587 uV, v_off_fin = 956.380 uV 14:49:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.978 uVs 14:49:17 Integrated Voltage Measurement... 14:49:26 Voltage Offset Correction: v_off_ini = 963.241 uV, v_off_fin = 970.865 uV 14:49:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.977 uVs 14:49:28 I2X Average and RMS of Measurements VT = -135.613 +- 4.338 uVs I2X = 12.476 +- 0.399 uTm^2 14:49:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:33 Integrated Voltage Measurement... 14:49:42 Voltage Offset Correction: v_off_ini = 976.651 uV, v_off_fin = 976.021 uV 14:49:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.634 uVs 14:49:42 Integrated Voltage Measurement... 14:49:51 Voltage Offset Correction: v_off_ini = 959.637 uV, v_off_fin = 959.952 uV 14:49:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.128 uVs 14:49:51 Integrated Voltage Measurement... 14:50:00 Voltage Offset Correction: v_off_ini = 962.023 uV, v_off_fin = 968.587 uV 14:50:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.487 uVs 14:50:00 Integrated Voltage Measurement... 14:50:09 Voltage Offset Correction: v_off_ini = 953.961 uV, v_off_fin = 967.422 uV 14:50:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.827 uVs 14:50:09 Integrated Voltage Measurement... 14:50:18 Voltage Offset Correction: v_off_ini = 969.736 uV, v_off_fin = 969.511 uV 14:50:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.981 uVs 14:50:18 Integrated Voltage Measurement... 14:50:27 Voltage Offset Correction: v_off_ini = 981.586 uV, v_off_fin = 994.368 uV 14:50:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.374 uVs 14:50:30 I2Y Average and RMS of Measurements VT = -243.239 +- 1.959 uVs I2Y = -22.378 +- 0.180 uTm^2 14:50:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:50:38 Integrated Voltage Measurement... 14:50:47 Voltage Offset Correction: v_off_ini = 982.402 uV, v_off_fin = 989.799 uV 14:50:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.207 uVs 14:50:47 Integrated Voltage Measurement... 14:50:56 Voltage Offset Correction: v_off_ini = 963.219 uV, v_off_fin = 991.340 uV 14:50:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.043 uVs 14:50:56 Integrated Voltage Measurement... 14:51:05 Voltage Offset Correction: v_off_ini = 998.410 uV, v_off_fin = 983.521 uV 14:51:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.330 uVs 14:51:05 Integrated Voltage Measurement... 14:51:14 Voltage Offset Correction: v_off_ini = 979.456 uV, v_off_fin = 1004.714 uV 14:51:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.168 uVs 14:51:14 Integrated Voltage Measurement... 14:51:23 Voltage Offset Correction: v_off_ini = 978.886 uV, v_off_fin = 972.862 uV 14:51:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.851 uVs 14:51:23 Integrated Voltage Measurement... 14:51:32 Voltage Offset Correction: v_off_ini = 967.178 uV, v_off_fin = 971.286 uV 14:51:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.573 uVs 14:51:37 I1X Average and RMS of Measurements VT = -125.862 +- 9.306 uVs I1X = 25.173 +- 1.861 uTm 14:51:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:51:43 Integrated Voltage Measurement... 14:51:52 Voltage Offset Correction: v_off_ini = 968.766 uV, v_off_fin = 955.137 uV 14:51:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.004 uVs 14:51:52 Integrated Voltage Measurement... 14:52:01 Voltage Offset Correction: v_off_ini = 955.833 uV, v_off_fin = 979.089 uV 14:52:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.442 uVs 14:52:01 Integrated Voltage Measurement... 14:52:10 Voltage Offset Correction: v_off_ini = 965.803 uV, v_off_fin = 986.603 uV 14:52:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.726 uVs 14:52:10 Integrated Voltage Measurement... 14:52:19 Voltage Offset Correction: v_off_ini = 996.665 uV, v_off_fin = 987.431 uV 14:52:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.800 uVs 14:52:19 Integrated Voltage Measurement... 14:52:28 Voltage Offset Correction: v_off_ini = 983.428 uV, v_off_fin = 961.622 uV 14:52:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.449 uVs 14:52:28 Integrated Voltage Measurement... 14:52:37 Voltage Offset Correction: v_off_ini = 967.395 uV, v_off_fin = 983.949 uV 14:52:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.220 uVs 14:52:42 I1Y Average and RMS of Measurements VT = -222.107 +- 6.596 uVs I1Y = -44.420 +- 1.321 uTm 14:52:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:52:47 Integrated Voltage Measurement... 14:52:56 Voltage Offset Correction: v_off_ini = 970.777 uV, v_off_fin = 970.724 uV 14:52:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.087 uVs 14:52:56 Integrated Voltage Measurement... 14:53:05 Voltage Offset Correction: v_off_ini = 980.794 uV, v_off_fin = 981.434 uV 14:53:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 153.883 uVs 14:53:05 Integrated Voltage Measurement... 14:53:14 Voltage Offset Correction: v_off_ini = 980.519 uV, v_off_fin = 979.682 uV 14:53:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.001 uVs 14:53:14 Integrated Voltage Measurement... 14:53:23 Voltage Offset Correction: v_off_ini = 988.669 uV, v_off_fin = 1000.848 uV 14:53:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.574 uVs 14:53:23 Integrated Voltage Measurement... 14:53:32 Voltage Offset Correction: v_off_ini = 954.620 uV, v_off_fin = 958.017 uV 14:53:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.629 uVs 14:53:32 Integrated Voltage Measurement... 14:53:41 Voltage Offset Correction: v_off_ini = 953.158 uV, v_off_fin = 966.057 uV 14:53:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.702 uVs 14:53:43 I2X Average and RMS of Measurements VT = -132.313 +- 4.374 uVs I2X = 12.173 +- 0.402 uTm^2 14:53:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:53:49 Integrated Voltage Measurement... 14:53:58 Voltage Offset Correction: v_off_ini = 958.676 uV, v_off_fin = 944.874 uV 14:53:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.536 uVs 14:53:58 Integrated Voltage Measurement... 14:54:07 Voltage Offset Correction: v_off_ini = 944.208 uV, v_off_fin = 950.192 uV 14:54:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.350 uVs 14:54:07 Integrated Voltage Measurement... 14:54:16 Voltage Offset Correction: v_off_ini = 975.423 uV, v_off_fin = 971.606 uV 14:54:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.037 uVs 14:54:16 Integrated Voltage Measurement... 14:54:25 Voltage Offset Correction: v_off_ini = 962.107 uV, v_off_fin = 959.298 uV 14:54:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.157 uVs 14:54:25 Integrated Voltage Measurement... 14:54:34 Voltage Offset Correction: v_off_ini = 956.905 uV, v_off_fin = 962.749 uV 14:54:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.043 uVs 14:54:34 Integrated Voltage Measurement... 14:54:43 Voltage Offset Correction: v_off_ini = 943.482 uV, v_off_fin = 947.594 uV 14:54:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.959 uVs 14:54:45 I2Y Average and RMS of Measurements VT = -233.514 +- 9.980 uVs I2Y = -21.483 +- 0.918 uTm^2 14:54:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:54:53 Integrated Voltage Measurement... 14:55:02 Voltage Offset Correction: v_off_ini = 929.664 uV, v_off_fin = 940.670 uV 14:55:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.538 uVs 14:55:03 Integrated Voltage Measurement... 14:55:11 Voltage Offset Correction: v_off_ini = 930.118 uV, v_off_fin = 928.950 uV 14:55:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.917 uVs 14:55:12 Integrated Voltage Measurement... 14:55:21 Voltage Offset Correction: v_off_ini = 930.913 uV, v_off_fin = 958.180 uV 14:55:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.228 uVs 14:55:21 Integrated Voltage Measurement... 14:55:30 Voltage Offset Correction: v_off_ini = 960.224 uV, v_off_fin = 961.094 uV 14:55:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.729 uVs 14:55:30 Integrated Voltage Measurement... 14:55:39 Voltage Offset Correction: v_off_ini = 917.636 uV, v_off_fin = 934.457 uV 14:55:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.373 uVs 14:55:39 Integrated Voltage Measurement... 14:55:48 Voltage Offset Correction: v_off_ini = 951.850 uV, v_off_fin = 928.697 uV 14:55:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.898 uVs 14:55:52 I1X Average and RMS of Measurements VT = -110.447 +- 6.675 uVs I1X = 22.090 +- 1.335 uTm 14:55:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:55:59 Integrated Voltage Measurement... 14:56:08 Voltage Offset Correction: v_off_ini = 918.738 uV, v_off_fin = 922.493 uV 14:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.824 uVs 14:56:08 Integrated Voltage Measurement... 14:56:17 Voltage Offset Correction: v_off_ini = 939.481 uV, v_off_fin = 942.999 uV 14:56:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.703 uVs 14:56:17 Integrated Voltage Measurement... 14:56:26 Voltage Offset Correction: v_off_ini = 935.902 uV, v_off_fin = 928.035 uV 14:56:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -224.871 uVs 14:56:26 Integrated Voltage Measurement... 14:56:35 Voltage Offset Correction: v_off_ini = 939.863 uV, v_off_fin = 949.539 uV 14:56:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 232.264 uVs 14:56:35 Integrated Voltage Measurement... 14:56:44 Voltage Offset Correction: v_off_ini = 944.963 uV, v_off_fin = 933.955 uV 14:56:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -219.277 uVs 14:56:44 Integrated Voltage Measurement... 14:56:53 Voltage Offset Correction: v_off_ini = 930.502 uV, v_off_fin = 956.122 uV 14:56:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 222.028 uVs 14:56:57 I1Y Average and RMS of Measurements VT = -225.328 +- 3.387 uVs I1Y = -45.059 +- 0.679 uTm 14:56:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:57:02 Integrated Voltage Measurement... 14:57:11 Voltage Offset Correction: v_off_ini = 916.229 uV, v_off_fin = 897.660 uV 14:57:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.873 uVs 14:57:11 Integrated Voltage Measurement... 14:57:20 Voltage Offset Correction: v_off_ini = 903.967 uV, v_off_fin = 920.359 uV 14:57:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.966 uVs 14:57:20 Integrated Voltage Measurement... 14:57:29 Voltage Offset Correction: v_off_ini = 928.115 uV, v_off_fin = 917.368 uV 14:57:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.686 uVs 14:57:29 Integrated Voltage Measurement... 14:57:38 Voltage Offset Correction: v_off_ini = 910.082 uV, v_off_fin = 912.577 uV 14:57:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.617 uVs 14:57:38 Integrated Voltage Measurement... 14:57:47 Voltage Offset Correction: v_off_ini = 910.848 uV, v_off_fin = 889.736 uV 14:57:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.450 uVs 14:57:47 Integrated Voltage Measurement... 14:57:56 Voltage Offset Correction: v_off_ini = 906.436 uV, v_off_fin = 919.611 uV 14:57:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.610 uVs 14:57:59 I2X Average and RMS of Measurements VT = -136.867 +- 7.954 uVs I2X = 12.592 +- 0.732 uTm^2 14:58:01 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:58:04 Integrated Voltage Measurement... 14:58:13 Voltage Offset Correction: v_off_ini = 921.895 uV, v_off_fin = 932.211 uV 14:58:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.486 uVs 14:58:13 Integrated Voltage Measurement... 14:58:22 Voltage Offset Correction: v_off_ini = 921.182 uV, v_off_fin = 922.076 uV 14:58:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.448 uVs 14:58:22 Integrated Voltage Measurement... 14:58:31 Voltage Offset Correction: v_off_ini = 915.509 uV, v_off_fin = 912.627 uV 14:58:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.885 uVs 14:58:31 Integrated Voltage Measurement... 14:58:40 Voltage Offset Correction: v_off_ini = 909.186 uV, v_off_fin = 914.245 uV 14:58:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.639 uVs 14:58:40 Integrated Voltage Measurement... 14:58:49 Voltage Offset Correction: v_off_ini = 923.698 uV, v_off_fin = 914.164 uV 14:58:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.341 uVs 14:58:49 Integrated Voltage Measurement... 14:58:58 Voltage Offset Correction: v_off_ini = 885.649 uV, v_off_fin = 908.444 uV 14:58:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.458 uVs 14:59:00 I2Y Average and RMS of Measurements VT = -237.043 +- 1.078 uVs I2Y = -21.808 +- 0.099 uTm^2 14:59:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:59:21 Integrated Voltage Measurement... 14:59:30 Voltage Offset Correction: v_off_ini = 894.572 uV, v_off_fin = 878.198 uV 14:59:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -175.728 uVs 14:59:30 Integrated Voltage Measurement... 14:59:39 Voltage Offset Correction: v_off_ini = 887.129 uV, v_off_fin = 903.347 uV 14:59:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.581 uVs 14:59:39 Integrated Voltage Measurement... 14:59:48 Voltage Offset Correction: v_off_ini = 911.473 uV, v_off_fin = 901.643 uV 14:59:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.776 uVs 14:59:48 Integrated Voltage Measurement... 14:59:57 Voltage Offset Correction: v_off_ini = 897.398 uV, v_off_fin = 909.420 uV 14:59:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.144 uVs 14:59:57 Integrated Voltage Measurement... 15:00:06 Voltage Offset Correction: v_off_ini = 918.882 uV, v_off_fin = 904.159 uV 15:00:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.401 uVs 15:00:06 Integrated Voltage Measurement... 15:00:15 Voltage Offset Correction: v_off_ini = 887.560 uV, v_off_fin = 913.926 uV 15:00:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.599 uVs 15:00:19 I1X Average and RMS of Measurements VT = -144.705 +- 2.690 uVs I1X = 28.941 +- 0.538 uTm 15:00:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:00:26 Integrated Voltage Measurement... 15:00:35 Voltage Offset Correction: v_off_ini = 902.203 uV, v_off_fin = 876.182 uV 15:00:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.606 uVs 15:00:35 Integrated Voltage Measurement... 15:00:44 Voltage Offset Correction: v_off_ini = 907.292 uV, v_off_fin = 902.279 uV 15:00:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.866 uVs 15:00:44 Integrated Voltage Measurement... 15:00:53 Voltage Offset Correction: v_off_ini = 896.330 uV, v_off_fin = 892.006 uV 15:00:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.955 uVs 15:00:53 Integrated Voltage Measurement... 15:01:02 Voltage Offset Correction: v_off_ini = 908.385 uV, v_off_fin = 913.413 uV 15:01:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.294 uVs 15:01:02 Integrated Voltage Measurement... 15:01:11 Voltage Offset Correction: v_off_ini = 900.804 uV, v_off_fin = 889.757 uV 15:01:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.724 uVs 15:01:11 Integrated Voltage Measurement... 15:01:20 Voltage Offset Correction: v_off_ini = 908.284 uV, v_off_fin = 908.429 uV 15:01:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.039 uVs 15:01:24 I1Y Average and RMS of Measurements VT = -218.581 +- 9.918 uVs I1Y = -43.716 +- 1.984 uTm 15:01:29 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:01:32 Integrated Voltage Measurement... 15:01:41 Voltage Offset Correction: v_off_ini = 871.384 uV, v_off_fin = 884.951 uV 15:01:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.514 uVs 15:01:41 Integrated Voltage Measurement... 15:01:50 Voltage Offset Correction: v_off_ini = 879.146 uV, v_off_fin = 889.954 uV 15:01:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 196.619 uVs 15:01:50 Integrated Voltage Measurement... 15:01:59 Voltage Offset Correction: v_off_ini = 893.383 uV, v_off_fin = 895.581 uV 15:01:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.461 uVs 15:01:59 Integrated Voltage Measurement... 15:02:08 Voltage Offset Correction: v_off_ini = 892.485 uV, v_off_fin = 890.089 uV 15:02:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.030 uVs 15:02:08 Integrated Voltage Measurement... 15:02:17 Voltage Offset Correction: v_off_ini = 883.046 uV, v_off_fin = 873.330 uV 15:02:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.736 uVs 15:02:17 Integrated Voltage Measurement... 15:02:26 Voltage Offset Correction: v_off_ini = 901.932 uV, v_off_fin = 904.387 uV 15:02:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.541 uVs 15:02:28 I2X Average and RMS of Measurements VT = -157.817 +- 17.639 uVs I2X = 14.519 +- 1.623 uTm^2 15:02:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:02:36 Integrated Voltage Measurement... 15:02:45 Voltage Offset Correction: v_off_ini = 853.833 uV, v_off_fin = 864.576 uV 15:02:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.716 uVs 15:02:45 Integrated Voltage Measurement... 15:02:54 Voltage Offset Correction: v_off_ini = 860.082 uV, v_off_fin = 897.655 uV 15:02:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.673 uVs 15:02:54 Integrated Voltage Measurement... 15:03:03 Voltage Offset Correction: v_off_ini = 888.784 uV, v_off_fin = 902.113 uV 15:03:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.467 uVs 15:03:03 Integrated Voltage Measurement... 15:03:12 Voltage Offset Correction: v_off_ini = 897.268 uV, v_off_fin = 895.113 uV 15:03:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.991 uVs 15:03:12 Integrated Voltage Measurement... 15:03:21 Voltage Offset Correction: v_off_ini = 870.508 uV, v_off_fin = 876.306 uV 15:03:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.189 uVs 15:03:21 Integrated Voltage Measurement... 15:03:30 Voltage Offset Correction: v_off_ini = 890.071 uV, v_off_fin = 888.224 uV 15:03:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.814 uVs 15:03:33 I2Y Average and RMS of Measurements VT = -231.142 +- 3.535 uVs I2Y = -21.265 +- 0.325 uTm^2 15:03:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:03:42 Integrated Voltage Measurement... 15:03:51 Voltage Offset Correction: v_off_ini = 918.718 uV, v_off_fin = 916.516 uV 15:03:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -124.749 uVs 15:03:51 Integrated Voltage Measurement... 15:04:00 Voltage Offset Correction: v_off_ini = 908.206 uV, v_off_fin = 922.065 uV 15:04:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.568 uVs 15:04:00 Integrated Voltage Measurement... 15:04:09 Voltage Offset Correction: v_off_ini = 926.001 uV, v_off_fin = 911.867 uV 15:04:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.820 uVs 15:04:09 Integrated Voltage Measurement... 15:04:18 Voltage Offset Correction: v_off_ini = 923.455 uV, v_off_fin = 920.442 uV 15:04:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.755 uVs 15:04:18 Integrated Voltage Measurement... 15:04:27 Voltage Offset Correction: v_off_ini = 933.761 uV, v_off_fin = 924.511 uV 15:04:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.374 uVs 15:04:27 Integrated Voltage Measurement... 15:04:36 Voltage Offset Correction: v_off_ini = 921.469 uV, v_off_fin = 928.699 uV 15:04:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.022 uVs 15:04:40 I1X Average and RMS of Measurements VT = -126.715 +- 4.653 uVs I1X = 25.343 +- 0.930 uTm 15:04:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:04:47 Integrated Voltage Measurement... 15:04:56 Voltage Offset Correction: v_off_ini = 933.040 uV, v_off_fin = 925.692 uV 15:04:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.382 uVs 15:04:56 Integrated Voltage Measurement... 15:05:05 Voltage Offset Correction: v_off_ini = 936.255 uV, v_off_fin = 934.479 uV 15:05:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.615 uVs 15:05:05 Integrated Voltage Measurement... 15:05:14 Voltage Offset Correction: v_off_ini = 931.755 uV, v_off_fin = 923.347 uV 15:05:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.409 uVs 15:05:14 Integrated Voltage Measurement... 15:05:23 Voltage Offset Correction: v_off_ini = 930.494 uV, v_off_fin = 952.114 uV 15:05:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.385 uVs 15:05:23 Integrated Voltage Measurement... 15:05:32 Voltage Offset Correction: v_off_ini = 931.781 uV, v_off_fin = 930.419 uV 15:05:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.545 uVs 15:05:32 Integrated Voltage Measurement... 15:05:41 Voltage Offset Correction: v_off_ini = 913.426 uV, v_off_fin = 940.781 uV 15:05:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.599 uVs 15:05:45 I1Y Average and RMS of Measurements VT = -214.989 +- 4.006 uVs I1Y = -42.999 +- 0.802 uTm 15:05:50 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:05:53 Integrated Voltage Measurement... 15:06:02 Voltage Offset Correction: v_off_ini = 924.577 uV, v_off_fin = 912.713 uV 15:06:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.058 uVs 15:06:02 Integrated Voltage Measurement... 15:06:11 Voltage Offset Correction: v_off_ini = 932.902 uV, v_off_fin = 924.366 uV 15:06:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.969 uVs 15:06:11 Integrated Voltage Measurement... 15:06:20 Voltage Offset Correction: v_off_ini = 911.667 uV, v_off_fin = 929.625 uV 15:06:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -161.754 uVs 15:06:20 Integrated Voltage Measurement... 15:06:29 Voltage Offset Correction: v_off_ini = 942.836 uV, v_off_fin = 939.950 uV 15:06:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.761 uVs 15:06:29 Integrated Voltage Measurement... 15:06:38 Voltage Offset Correction: v_off_ini = 934.811 uV, v_off_fin = 931.935 uV 15:06:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -170.062 uVs 15:06:38 Integrated Voltage Measurement... 15:06:47 Voltage Offset Correction: v_off_ini = 939.738 uV, v_off_fin = 945.079 uV 15:06:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.288 uVs 15:06:49 I2X Average and RMS of Measurements VT = -152.649 +- 10.802 uVs I2X = 14.044 +- 0.994 uTm^2 15:06:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:06:57 Integrated Voltage Measurement... 15:07:06 Voltage Offset Correction: v_off_ini = 942.369 uV, v_off_fin = 940.925 uV 15:07:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.775 uVs 15:07:06 Integrated Voltage Measurement... 15:07:15 Voltage Offset Correction: v_off_ini = 948.773 uV, v_off_fin = 960.784 uV 15:07:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.332 uVs 15:07:15 Integrated Voltage Measurement... 15:07:24 Voltage Offset Correction: v_off_ini = 958.684 uV, v_off_fin = 946.868 uV 15:07:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.336 uVs 15:07:24 Integrated Voltage Measurement... 15:07:33 Voltage Offset Correction: v_off_ini = 945.820 uV, v_off_fin = 959.234 uV 15:07:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.207 uVs 15:07:33 Integrated Voltage Measurement... 15:07:42 Voltage Offset Correction: v_off_ini = 951.243 uV, v_off_fin = 960.430 uV 15:07:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.161 uVs 15:07:42 Integrated Voltage Measurement... 15:07:51 Voltage Offset Correction: v_off_ini = 958.190 uV, v_off_fin = 957.136 uV 15:07:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.068 uVs 15:07:54 I2Y Average and RMS of Measurements VT = -234.813 +- 5.242 uVs I2Y = -21.603 +- 0.482 uTm^2 15:07:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:03 Integrated Voltage Measurement... 15:08:12 Voltage Offset Correction: v_off_ini = 942.714 uV, v_off_fin = 952.618 uV 15:08:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.386 uVs 15:08:12 Integrated Voltage Measurement... 15:08:21 Voltage Offset Correction: v_off_ini = 929.650 uV, v_off_fin = 921.863 uV 15:08:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.299 uVs 15:08:21 Integrated Voltage Measurement... 15:08:30 Voltage Offset Correction: v_off_ini = 943.740 uV, v_off_fin = 919.761 uV 15:08:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.263 uVs 15:08:30 Integrated Voltage Measurement... 15:08:39 Voltage Offset Correction: v_off_ini = 935.252 uV, v_off_fin = 930.978 uV 15:08:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.780 uVs 15:08:39 Integrated Voltage Measurement... 15:08:48 Voltage Offset Correction: v_off_ini = 932.013 uV, v_off_fin = 926.924 uV 15:08:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.450 uVs 15:08:48 Integrated Voltage Measurement... 15:08:57 Voltage Offset Correction: v_off_ini = 929.245 uV, v_off_fin = 936.647 uV 15:08:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 111.187 uVs 15:09:01 I1X Average and RMS of Measurements VT = -131.727 +- 12.734 uVs I1X = 26.346 +- 2.546 uTm 15:09:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:08 Integrated Voltage Measurement... 15:09:17 Voltage Offset Correction: v_off_ini = 905.996 uV, v_off_fin = 919.086 uV 15:09:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.336 uVs 15:09:17 Integrated Voltage Measurement... 15:09:26 Voltage Offset Correction: v_off_ini = 931.485 uV, v_off_fin = 955.316 uV 15:09:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.556 uVs 15:09:26 Integrated Voltage Measurement... 15:09:35 Voltage Offset Correction: v_off_ini = 904.242 uV, v_off_fin = 926.005 uV 15:09:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.818 uVs 15:09:35 Integrated Voltage Measurement... 15:09:44 Voltage Offset Correction: v_off_ini = 940.944 uV, v_off_fin = 962.647 uV 15:09:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.474 uVs 15:09:44 Integrated Voltage Measurement... 15:09:53 Voltage Offset Correction: v_off_ini = 952.877 uV, v_off_fin = 925.788 uV 15:09:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.935 uVs 15:09:53 Integrated Voltage Measurement... 15:10:02 Voltage Offset Correction: v_off_ini = 928.671 uV, v_off_fin = 932.743 uV 15:10:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.127 uVs 15:10:06 I1Y Average and RMS of Measurements VT = -235.041 +- 7.450 uVs I1Y = -47.008 +- 1.490 uTm 15:10:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:14 Integrated Voltage Measurement... 15:10:23 Voltage Offset Correction: v_off_ini = 913.620 uV, v_off_fin = 910.762 uV 15:10:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.103 uVs 15:10:23 Integrated Voltage Measurement... 15:10:32 Voltage Offset Correction: v_off_ini = 894.229 uV, v_off_fin = 919.528 uV 15:10:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.477 uVs 15:10:32 Integrated Voltage Measurement... 15:10:41 Voltage Offset Correction: v_off_ini = 913.134 uV, v_off_fin = 929.866 uV 15:10:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.226 uVs 15:10:41 Integrated Voltage Measurement... 15:10:50 Voltage Offset Correction: v_off_ini = 945.814 uV, v_off_fin = 950.656 uV 15:10:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.989 uVs 15:10:50 Integrated Voltage Measurement... 15:10:59 Voltage Offset Correction: v_off_ini = 929.286 uV, v_off_fin = 907.362 uV 15:10:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.123 uVs 15:10:59 Integrated Voltage Measurement... 15:11:08 Voltage Offset Correction: v_off_ini = 946.293 uV, v_off_fin = 926.640 uV 15:11:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.730 uVs 15:11:10 I2X Average and RMS of Measurements VT = -143.108 +- 2.527 uVs I2X = 13.166 +- 0.232 uTm^2 15:11:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:18 Integrated Voltage Measurement... 15:11:27 Voltage Offset Correction: v_off_ini = 914.955 uV, v_off_fin = 929.224 uV 15:11:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.913 uVs 15:11:27 Integrated Voltage Measurement... 15:11:36 Voltage Offset Correction: v_off_ini = 939.532 uV, v_off_fin = 929.655 uV 15:11:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.783 uVs 15:11:36 Integrated Voltage Measurement... 15:11:45 Voltage Offset Correction: v_off_ini = 920.368 uV, v_off_fin = 913.743 uV 15:11:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.952 uVs 15:11:45 Integrated Voltage Measurement... 15:11:54 Voltage Offset Correction: v_off_ini = 920.993 uV, v_off_fin = 927.951 uV 15:11:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.173 uVs 15:11:54 Integrated Voltage Measurement... 15:12:03 Voltage Offset Correction: v_off_ini = 925.258 uV, v_off_fin = 927.100 uV 15:12:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.312 uVs 15:12:03 Integrated Voltage Measurement... 15:12:12 Voltage Offset Correction: v_off_ini = 947.938 uV, v_off_fin = 923.696 uV 15:12:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.891 uVs 15:12:14 I2Y Average and RMS of Measurements VT = -236.171 +- 12.492 uVs I2Y = -21.728 +- 1.149 uTm^2 15:12:19 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:12:23 Integrated Voltage Measurement... 15:12:32 Voltage Offset Correction: v_off_ini = 934.006 uV, v_off_fin = 948.786 uV 15:12:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -124.317 uVs 15:12:32 Integrated Voltage Measurement... 15:12:41 Voltage Offset Correction: v_off_ini = 949.662 uV, v_off_fin = 942.292 uV 15:12:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.113 uVs 15:12:41 Integrated Voltage Measurement... 15:12:50 Voltage Offset Correction: v_off_ini = 923.069 uV, v_off_fin = 943.015 uV 15:12:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.544 uVs 15:12:50 Integrated Voltage Measurement... 15:12:59 Voltage Offset Correction: v_off_ini = 952.540 uV, v_off_fin = 958.419 uV 15:12:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.587 uVs 15:12:59 Integrated Voltage Measurement... 15:13:08 Voltage Offset Correction: v_off_ini = 948.333 uV, v_off_fin = 962.349 uV 15:13:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.596 uVs 15:13:08 Integrated Voltage Measurement... 15:13:17 Voltage Offset Correction: v_off_ini = 944.737 uV, v_off_fin = 944.575 uV 15:13:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.086 uVs 15:13:22 I1X Average and RMS of Measurements VT = -121.374 +- 14.594 uVs I1X = 24.275 +- 2.919 uTm 15:13:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:13:28 Integrated Voltage Measurement... 15:13:37 Voltage Offset Correction: v_off_ini = 942.981 uV, v_off_fin = 939.807 uV 15:13:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.916 uVs 15:13:37 Integrated Voltage Measurement... 15:13:46 Voltage Offset Correction: v_off_ini = 935.059 uV, v_off_fin = 933.060 uV 15:13:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.109 uVs 15:13:46 Integrated Voltage Measurement... 15:13:55 Voltage Offset Correction: v_off_ini = 943.432 uV, v_off_fin = 925.618 uV 15:13:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.960 uVs 15:13:55 Integrated Voltage Measurement... 15:14:04 Voltage Offset Correction: v_off_ini = 960.505 uV, v_off_fin = 972.157 uV 15:14:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.318 uVs 15:14:04 Integrated Voltage Measurement... 15:14:13 Voltage Offset Correction: v_off_ini = 960.510 uV, v_off_fin = 950.445 uV 15:14:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.974 uVs 15:14:13 Integrated Voltage Measurement... 15:14:22 Voltage Offset Correction: v_off_ini = 949.022 uV, v_off_fin = 971.234 uV 15:14:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.740 uVs 15:14:27 I1Y Average and RMS of Measurements VT = -233.503 +- 8.488 uVs I1Y = -46.701 +- 1.698 uTm 15:14:32 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:14:34 Integrated Voltage Measurement... 15:14:43 Voltage Offset Correction: v_off_ini = 941.961 uV, v_off_fin = 967.599 uV 15:14:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.529 uVs 15:14:43 Integrated Voltage Measurement... 15:14:52 Voltage Offset Correction: v_off_ini = 972.308 uV, v_off_fin = 971.488 uV 15:14:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.984 uVs 15:14:52 Integrated Voltage Measurement... 15:15:01 Voltage Offset Correction: v_off_ini = 966.587 uV, v_off_fin = 961.772 uV 15:15:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.192 uVs 15:15:02 Integrated Voltage Measurement... 15:15:11 Voltage Offset Correction: v_off_ini = 959.980 uV, v_off_fin = 949.785 uV 15:15:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.181 uVs 15:15:11 Integrated Voltage Measurement... 15:15:20 Voltage Offset Correction: v_off_ini = 945.723 uV, v_off_fin = 935.841 uV 15:15:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.668 uVs 15:15:20 Integrated Voltage Measurement... 15:15:29 Voltage Offset Correction: v_off_ini = 955.689 uV, v_off_fin = 962.178 uV 15:15:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.887 uVs 15:15:31 I2X Average and RMS of Measurements VT = -139.574 +- 7.516 uVs I2X = 12.841 +- 0.692 uTm^2 15:15:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:15:39 Integrated Voltage Measurement... 15:15:48 Voltage Offset Correction: v_off_ini = 954.169 uV, v_off_fin = 957.037 uV 15:15:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.949 uVs 15:15:48 Integrated Voltage Measurement... 15:15:57 Voltage Offset Correction: v_off_ini = 959.638 uV, v_off_fin = 972.519 uV 15:15:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.666 uVs 15:15:57 Integrated Voltage Measurement... 15:16:06 Voltage Offset Correction: v_off_ini = 972.377 uV, v_off_fin = 978.563 uV 15:16:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.883 uVs 15:16:06 Integrated Voltage Measurement... 15:16:15 Voltage Offset Correction: v_off_ini = 976.174 uV, v_off_fin = 982.873 uV 15:16:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.110 uVs 15:16:15 Integrated Voltage Measurement... 15:16:24 Voltage Offset Correction: v_off_ini = 976.937 uV, v_off_fin = 965.734 uV 15:16:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.553 uVs 15:16:24 Integrated Voltage Measurement... 15:16:33 Voltage Offset Correction: v_off_ini = 966.828 uV, v_off_fin = 975.591 uV 15:16:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.269 uVs 15:16:35 I2Y Average and RMS of Measurements VT = -232.905 +- 2.143 uVs I2Y = -21.427 +- 0.197 uTm^2 15:16:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:16:44 Integrated Voltage Measurement... 15:16:53 Voltage Offset Correction: v_off_ini = 954.866 uV, v_off_fin = 953.099 uV 15:16:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.673 uVs 15:16:53 Integrated Voltage Measurement... 15:17:02 Voltage Offset Correction: v_off_ini = 978.768 uV, v_off_fin = 966.912 uV 15:17:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.984 uVs 15:17:02 Integrated Voltage Measurement... 15:17:11 Voltage Offset Correction: v_off_ini = 977.955 uV, v_off_fin = 971.890 uV 15:17:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.826 uVs 15:17:11 Integrated Voltage Measurement... 15:17:20 Voltage Offset Correction: v_off_ini = 968.643 uV, v_off_fin = 964.909 uV 15:17:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.613 uVs 15:17:20 Integrated Voltage Measurement... 15:17:29 Voltage Offset Correction: v_off_ini = 966.963 uV, v_off_fin = 949.682 uV 15:17:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.359 uVs 15:17:29 Integrated Voltage Measurement... 15:17:38 Voltage Offset Correction: v_off_ini = 951.056 uV, v_off_fin = 959.717 uV 15:17:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.420 uVs 15:17:43 I1X Average and RMS of Measurements VT = -132.979 +- 5.324 uVs I1X = 26.596 +- 1.065 uTm 15:17:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:17:49 Integrated Voltage Measurement... 15:17:58 Voltage Offset Correction: v_off_ini = 967.041 uV, v_off_fin = 957.951 uV 15:17:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.188 uVs 15:17:58 Integrated Voltage Measurement... 15:18:07 Voltage Offset Correction: v_off_ini = 958.402 uV, v_off_fin = 974.380 uV 15:18:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.998 uVs 15:18:07 Integrated Voltage Measurement... 15:18:16 Voltage Offset Correction: v_off_ini = 970.214 uV, v_off_fin = 961.766 uV 15:18:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.908 uVs 15:18:16 Integrated Voltage Measurement... 15:18:25 Voltage Offset Correction: v_off_ini = 932.308 uV, v_off_fin = 959.179 uV 15:18:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.356 uVs 15:18:25 Integrated Voltage Measurement... 15:18:34 Voltage Offset Correction: v_off_ini = 947.959 uV, v_off_fin = 940.802 uV 15:18:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.023 uVs 15:18:34 Integrated Voltage Measurement... 15:18:43 Voltage Offset Correction: v_off_ini = 958.817 uV, v_off_fin = 959.894 uV 15:18:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.728 uVs 15:18:48 I1Y Average and RMS of Measurements VT = -232.867 +- 2.801 uVs I1Y = -46.573 +- 0.560 uTm 15:18:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:18:55 Integrated Voltage Measurement... 15:19:04 Voltage Offset Correction: v_off_ini = 961.515 uV, v_off_fin = 944.389 uV 15:19:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.155 uVs 15:19:04 Integrated Voltage Measurement... 15:19:13 Voltage Offset Correction: v_off_ini = 943.364 uV, v_off_fin = 962.102 uV 15:19:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.801 uVs 15:19:13 Integrated Voltage Measurement... 15:19:22 Voltage Offset Correction: v_off_ini = 961.914 uV, v_off_fin = 947.304 uV 15:19:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.050 uVs 15:19:23 Integrated Voltage Measurement... 15:19:31 Voltage Offset Correction: v_off_ini = 941.167 uV, v_off_fin = 961.379 uV 15:19:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.866 uVs 15:19:32 Integrated Voltage Measurement... 15:19:41 Voltage Offset Correction: v_off_ini = 945.498 uV, v_off_fin = 931.081 uV 15:19:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.219 uVs 15:19:41 Integrated Voltage Measurement... 15:19:50 Voltage Offset Correction: v_off_ini = 970.221 uV, v_off_fin = 999.077 uV 15:19:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.868 uVs 15:19:52 I2X Average and RMS of Measurements VT = -134.326 +- 7.335 uVs I2X = 12.358 +- 0.675 uTm^2 15:19:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:20:00 Integrated Voltage Measurement... 15:20:09 Voltage Offset Correction: v_off_ini = 976.335 uV, v_off_fin = 959.079 uV 15:20:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.946 uVs 15:20:09 Integrated Voltage Measurement... 15:20:18 Voltage Offset Correction: v_off_ini = 968.197 uV, v_off_fin = 969.335 uV 15:20:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.457 uVs 15:20:18 Integrated Voltage Measurement... 15:20:27 Voltage Offset Correction: v_off_ini = 967.901 uV, v_off_fin = 958.636 uV 15:20:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.325 uVs 15:20:27 Integrated Voltage Measurement... 15:20:36 Voltage Offset Correction: v_off_ini = 967.760 uV, v_off_fin = 971.063 uV 15:20:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.774 uVs 15:20:36 Integrated Voltage Measurement... 15:20:45 Voltage Offset Correction: v_off_ini = 976.419 uV, v_off_fin = 975.217 uV 15:20:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.225 uVs 15:20:45 Integrated Voltage Measurement... 15:20:54 Voltage Offset Correction: v_off_ini = 963.373 uV, v_off_fin = 979.818 uV 15:20:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.812 uVs 15:20:56 I2Y Average and RMS of Measurements VT = -241.257 +- 11.146 uVs I2Y = -22.196 +- 1.025 uTm^2 15:21:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:21:08 Integrated Voltage Measurement... 15:21:17 Voltage Offset Correction: v_off_ini = 951.699 uV, v_off_fin = 961.370 uV 15:21:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.884 uVs 15:21:17 Integrated Voltage Measurement... 15:21:26 Voltage Offset Correction: v_off_ini = 966.557 uV, v_off_fin = 962.964 uV 15:21:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.952 uVs 15:21:26 Integrated Voltage Measurement... 15:21:35 Voltage Offset Correction: v_off_ini = 965.935 uV, v_off_fin = 976.887 uV 15:21:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.639 uVs 15:21:35 Integrated Voltage Measurement... 15:21:44 Voltage Offset Correction: v_off_ini = 970.756 uV, v_off_fin = 964.585 uV 15:21:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.260 uVs 15:21:45 Integrated Voltage Measurement... 15:21:53 Voltage Offset Correction: v_off_ini = 936.231 uV, v_off_fin = 951.386 uV 15:21:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.826 uVs 15:21:54 Integrated Voltage Measurement... 15:22:02 Voltage Offset Correction: v_off_ini = 967.882 uV, v_off_fin = 956.227 uV 15:22:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.147 uVs 15:22:07 I1X Average and RMS of Measurements VT = -130.285 +- 9.177 uVs I1X = 26.057 +- 1.835 uTm 15:22:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:22:14 Integrated Voltage Measurement... 15:22:22 Voltage Offset Correction: v_off_ini = 944.165 uV, v_off_fin = 941.738 uV 15:22:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.468 uVs 15:22:23 Integrated Voltage Measurement... 15:22:31 Voltage Offset Correction: v_off_ini = 926.207 uV, v_off_fin = 948.882 uV 15:22:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.772 uVs 15:22:32 Integrated Voltage Measurement... 15:22:40 Voltage Offset Correction: v_off_ini = 947.085 uV, v_off_fin = 936.658 uV 15:22:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.473 uVs 15:22:41 Integrated Voltage Measurement... 15:22:49 Voltage Offset Correction: v_off_ini = 942.665 uV, v_off_fin = 957.644 uV 15:22:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.948 uVs 15:22:50 Integrated Voltage Measurement... 15:22:59 Voltage Offset Correction: v_off_ini = 943.021 uV, v_off_fin = 927.170 uV 15:22:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.227 uVs 15:22:59 Integrated Voltage Measurement... 15:23:08 Voltage Offset Correction: v_off_ini = 951.322 uV, v_off_fin = 954.849 uV 15:23:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.502 uVs 15:23:12 I1Y Average and RMS of Measurements VT = -228.732 +- 1.081 uVs I1Y = -45.746 +- 0.216 uTm 15:23:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:23:17 Integrated Voltage Measurement... 15:23:26 Voltage Offset Correction: v_off_ini = 939.916 uV, v_off_fin = 930.692 uV 15:23:26 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -153.206 uVs 15:23:26 Integrated Voltage Measurement... 15:23:35 Voltage Offset Correction: v_off_ini = 926.122 uV, v_off_fin = 939.927 uV 15:23:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.617 uVs 15:23:35 Integrated Voltage Measurement... 15:23:44 Voltage Offset Correction: v_off_ini = 909.704 uV, v_off_fin = 907.320 uV 15:23:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.998 uVs 15:23:44 Integrated Voltage Measurement... 15:23:53 Voltage Offset Correction: v_off_ini = 936.971 uV, v_off_fin = 942.835 uV 15:23:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 163.876 uVs 15:23:53 Integrated Voltage Measurement... 15:24:02 Voltage Offset Correction: v_off_ini = 946.992 uV, v_off_fin = 933.716 uV 15:24:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.076 uVs 15:24:02 Integrated Voltage Measurement... 15:24:11 Voltage Offset Correction: v_off_ini = 942.323 uV, v_off_fin = 941.289 uV 15:24:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.941 uVs 15:24:13 I2X Average and RMS of Measurements VT = -152.619 +- 3.461 uVs I2X = 14.040 +- 0.318 uTm^2 15:24:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:24:19 Integrated Voltage Measurement... 15:24:28 Voltage Offset Correction: v_off_ini = 937.306 uV, v_off_fin = 925.222 uV 15:24:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.437 uVs 15:24:28 Integrated Voltage Measurement... 15:24:37 Voltage Offset Correction: v_off_ini = 945.641 uV, v_off_fin = 938.834 uV 15:24:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.523 uVs 15:24:37 Integrated Voltage Measurement... 15:24:46 Voltage Offset Correction: v_off_ini = 935.023 uV, v_off_fin = 932.757 uV 15:24:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.593 uVs 15:24:46 Integrated Voltage Measurement... 15:24:55 Voltage Offset Correction: v_off_ini = 929.928 uV, v_off_fin = 934.696 uV 15:24:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.712 uVs 15:24:55 Integrated Voltage Measurement... 15:25:04 Voltage Offset Correction: v_off_ini = 916.893 uV, v_off_fin = 908.868 uV 15:25:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.723 uVs 15:25:04 Integrated Voltage Measurement... 15:25:13 Voltage Offset Correction: v_off_ini = 910.510 uV, v_off_fin = 932.285 uV 15:25:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.533 uVs 15:25:15 I2Y Average and RMS of Measurements VT = -249.254 +- 7.529 uVs I2Y = -22.931 +- 0.693 uTm^2 15:25:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:25:24 Integrated Voltage Measurement... 15:25:33 Voltage Offset Correction: v_off_ini = 932.600 uV, v_off_fin = 937.311 uV 15:25:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -123.749 uVs 15:25:33 Integrated Voltage Measurement... 15:25:42 Voltage Offset Correction: v_off_ini = 936.475 uV, v_off_fin = 940.909 uV 15:25:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.350 uVs 15:25:42 Integrated Voltage Measurement... 15:25:51 Voltage Offset Correction: v_off_ini = 935.932 uV, v_off_fin = 942.159 uV 15:25:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.024 uVs 15:25:51 Integrated Voltage Measurement... 15:26:00 Voltage Offset Correction: v_off_ini = 937.898 uV, v_off_fin = 959.181 uV 15:26:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.049 uVs 15:26:00 Integrated Voltage Measurement... 15:26:09 Voltage Offset Correction: v_off_ini = 948.324 uV, v_off_fin = 951.142 uV 15:26:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.838 uVs 15:26:09 Integrated Voltage Measurement... 15:26:18 Voltage Offset Correction: v_off_ini = 932.421 uV, v_off_fin = 948.264 uV 15:26:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.654 uVs 15:26:22 I1X Average and RMS of Measurements VT = -127.277 +- 7.976 uVs I1X = 25.456 +- 1.595 uTm 15:26:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:26:29 Integrated Voltage Measurement... 15:26:38 Voltage Offset Correction: v_off_ini = 939.628 uV, v_off_fin = 943.520 uV 15:26:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.436 uVs 15:26:38 Integrated Voltage Measurement... 15:26:47 Voltage Offset Correction: v_off_ini = 946.037 uV, v_off_fin = 966.271 uV 15:26:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.851 uVs 15:26:47 Integrated Voltage Measurement... 15:26:56 Voltage Offset Correction: v_off_ini = 956.077 uV, v_off_fin = 953.683 uV 15:26:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.008 uVs 15:26:56 Integrated Voltage Measurement... 15:27:05 Voltage Offset Correction: v_off_ini = 956.240 uV, v_off_fin = 963.152 uV 15:27:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.976 uVs 15:27:05 Integrated Voltage Measurement... 15:27:14 Voltage Offset Correction: v_off_ini = 961.628 uV, v_off_fin = 936.105 uV 15:27:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.268 uVs 15:27:14 Integrated Voltage Measurement... 15:27:23 Voltage Offset Correction: v_off_ini = 925.350 uV, v_off_fin = 963.760 uV 15:27:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.653 uVs 15:27:27 I1Y Average and RMS of Measurements VT = -227.532 +- 2.779 uVs I1Y = -45.506 +- 0.556 uTm 15:27:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:27:32 Integrated Voltage Measurement... 15:27:41 Voltage Offset Correction: v_off_ini = 938.215 uV, v_off_fin = 919.120 uV 15:27:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.238 uVs 15:27:41 Integrated Voltage Measurement... 15:27:50 Voltage Offset Correction: v_off_ini = 950.776 uV, v_off_fin = 915.194 uV 15:27:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 168.245 uVs 15:27:50 Integrated Voltage Measurement... 15:27:59 Voltage Offset Correction: v_off_ini = 928.095 uV, v_off_fin = 933.884 uV 15:27:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.373 uVs 15:27:59 Integrated Voltage Measurement... 15:28:08 Voltage Offset Correction: v_off_ini = 949.259 uV, v_off_fin = 944.601 uV 15:28:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.617 uVs 15:28:08 Integrated Voltage Measurement... 15:28:17 Voltage Offset Correction: v_off_ini = 955.324 uV, v_off_fin = 965.840 uV 15:28:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -159.965 uVs 15:28:17 Integrated Voltage Measurement... 15:28:26 Voltage Offset Correction: v_off_ini = 950.740 uV, v_off_fin = 953.067 uV 15:28:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.059 uVs 15:28:29 I2X Average and RMS of Measurements VT = -145.083 +- 2.416 uVs I2X = 13.348 +- 0.222 uTm^2 15:28:31 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:28:34 Integrated Voltage Measurement... 15:28:43 Voltage Offset Correction: v_off_ini = 927.365 uV, v_off_fin = 938.126 uV 15:28:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.105 uVs 15:28:43 Integrated Voltage Measurement... 15:28:52 Voltage Offset Correction: v_off_ini = 939.973 uV, v_off_fin = 940.675 uV 15:28:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.618 uVs 15:28:52 Integrated Voltage Measurement... 15:29:01 Voltage Offset Correction: v_off_ini = 910.590 uV, v_off_fin = 909.548 uV 15:29:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.451 uVs 15:29:01 Integrated Voltage Measurement... 15:29:10 Voltage Offset Correction: v_off_ini = 932.594 uV, v_off_fin = 941.119 uV 15:29:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.256 uVs 15:29:10 Integrated Voltage Measurement... 15:29:19 Voltage Offset Correction: v_off_ini = 944.023 uV, v_off_fin = 936.413 uV 15:29:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.750 uVs 15:29:19 Integrated Voltage Measurement... 15:29:28 Voltage Offset Correction: v_off_ini = 947.109 uV, v_off_fin = 938.963 uV 15:29:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.554 uVs 15:29:30 I2Y Average and RMS of Measurements VT = -237.289 +- 4.698 uVs I2Y = -21.831 +- 0.432 uTm^2 15:29:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:39 Integrated Voltage Measurement... 15:29:48 Voltage Offset Correction: v_off_ini = 960.570 uV, v_off_fin = 944.036 uV 15:29:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.708 uVs 15:29:48 Integrated Voltage Measurement... 15:29:57 Voltage Offset Correction: v_off_ini = 942.322 uV, v_off_fin = 962.693 uV 15:29:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 117.944 uVs 15:29:57 Integrated Voltage Measurement... 15:30:06 Voltage Offset Correction: v_off_ini = 931.219 uV, v_off_fin = 943.381 uV 15:30:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.644 uVs 15:30:06 Integrated Voltage Measurement... 15:30:15 Voltage Offset Correction: v_off_ini = 951.768 uV, v_off_fin = 944.530 uV 15:30:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.494 uVs 15:30:15 Integrated Voltage Measurement... 15:30:24 Voltage Offset Correction: v_off_ini = 956.902 uV, v_off_fin = 950.603 uV 15:30:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.016 uVs 15:30:24 Integrated Voltage Measurement... 15:30:33 Voltage Offset Correction: v_off_ini = 959.314 uV, v_off_fin = 962.192 uV 15:30:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.124 uVs 15:30:37 I1X Average and RMS of Measurements VT = -126.322 +- 7.452 uVs I1X = 25.265 +- 1.490 uTm 15:30:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:44 Integrated Voltage Measurement... 15:30:53 Voltage Offset Correction: v_off_ini = 979.585 uV, v_off_fin = 945.946 uV 15:30:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.919 uVs 15:30:53 Integrated Voltage Measurement... 15:31:02 Voltage Offset Correction: v_off_ini = 949.550 uV, v_off_fin = 971.162 uV 15:31:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.534 uVs 15:31:02 Integrated Voltage Measurement... 15:31:11 Voltage Offset Correction: v_off_ini = 959.167 uV, v_off_fin = 936.395 uV 15:31:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.740 uVs 15:31:11 Integrated Voltage Measurement... 15:31:20 Voltage Offset Correction: v_off_ini = 948.811 uV, v_off_fin = 965.240 uV 15:31:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.689 uVs 15:31:20 Integrated Voltage Measurement... 15:31:29 Voltage Offset Correction: v_off_ini = 950.181 uV, v_off_fin = 946.162 uV 15:31:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.011 uVs 15:31:29 Integrated Voltage Measurement... 15:31:38 Voltage Offset Correction: v_off_ini = 936.542 uV, v_off_fin = 951.490 uV 15:31:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.742 uVs 15:31:42 I1Y Average and RMS of Measurements VT = -225.106 +- 10.557 uVs I1Y = -45.021 +- 2.111 uTm 15:31:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:47 Integrated Voltage Measurement... 15:31:56 Voltage Offset Correction: v_off_ini = 932.185 uV, v_off_fin = 937.884 uV 15:31:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.705 uVs 15:31:56 Integrated Voltage Measurement... 15:32:05 Voltage Offset Correction: v_off_ini = 940.273 uV, v_off_fin = 942.407 uV 15:32:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.911 uVs 15:32:05 Integrated Voltage Measurement... 15:32:14 Voltage Offset Correction: v_off_ini = 931.127 uV, v_off_fin = 925.051 uV 15:32:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.149 uVs 15:32:14 Integrated Voltage Measurement... 15:32:23 Voltage Offset Correction: v_off_ini = 939.980 uV, v_off_fin = 951.457 uV 15:32:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.792 uVs 15:32:24 Integrated Voltage Measurement... 15:32:32 Voltage Offset Correction: v_off_ini = 951.204 uV, v_off_fin = 950.481 uV 15:32:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.266 uVs 15:32:33 Integrated Voltage Measurement... 15:32:42 Voltage Offset Correction: v_off_ini = 934.625 uV, v_off_fin = 953.128 uV 15:32:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.275 uVs 15:32:44 I2X Average and RMS of Measurements VT = -142.516 +- 2.023 uVs I2X = 13.111 +- 0.186 uTm^2 15:32:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:32:49 Integrated Voltage Measurement... 15:32:58 Voltage Offset Correction: v_off_ini = 924.545 uV, v_off_fin = 922.941 uV 15:32:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.484 uVs 15:32:58 Integrated Voltage Measurement... 15:33:07 Voltage Offset Correction: v_off_ini = 929.991 uV, v_off_fin = 929.672 uV 15:33:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 239.546 uVs 15:33:07 Integrated Voltage Measurement... 15:33:16 Voltage Offset Correction: v_off_ini = 944.584 uV, v_off_fin = 938.424 uV 15:33:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.792 uVs 15:33:16 Integrated Voltage Measurement... 15:33:25 Voltage Offset Correction: v_off_ini = 919.210 uV, v_off_fin = 911.977 uV 15:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.193 uVs 15:33:25 Integrated Voltage Measurement... 15:33:34 Voltage Offset Correction: v_off_ini = 934.106 uV, v_off_fin = 934.164 uV 15:33:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.061 uVs 15:33:34 Integrated Voltage Measurement... 15:33:43 Voltage Offset Correction: v_off_ini = 916.535 uV, v_off_fin = 917.691 uV 15:33:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.266 uVs 15:33:46 I2Y Average and RMS of Measurements VT = -235.390 +- 4.095 uVs I2Y = -21.656 +- 0.377 uTm^2 15:33:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:33:54 Integrated Voltage Measurement... 15:34:03 Voltage Offset Correction: v_off_ini = 916.962 uV, v_off_fin = 932.048 uV 15:34:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -129.727 uVs 15:34:03 Integrated Voltage Measurement... 15:34:12 Voltage Offset Correction: v_off_ini = 920.024 uV, v_off_fin = 930.908 uV 15:34:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.621 uVs 15:34:12 Integrated Voltage Measurement... 15:34:21 Voltage Offset Correction: v_off_ini = 921.779 uV, v_off_fin = 910.200 uV 15:34:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.704 uVs 15:34:21 Integrated Voltage Measurement... 15:34:30 Voltage Offset Correction: v_off_ini = 924.631 uV, v_off_fin = 932.036 uV 15:34:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.100 uVs 15:34:30 Integrated Voltage Measurement... 15:34:39 Voltage Offset Correction: v_off_ini = 923.245 uV, v_off_fin = 900.379 uV 15:34:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.197 uVs 15:34:39 Integrated Voltage Measurement... 15:34:48 Voltage Offset Correction: v_off_ini = 901.961 uV, v_off_fin = 909.870 uV 15:34:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.425 uVs 15:34:52 I1X Average and RMS of Measurements VT = -117.962 +- 2.563 uVs I1X = 23.593 +- 0.513 uTm 15:34:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:34:59 Integrated Voltage Measurement... 15:35:08 Voltage Offset Correction: v_off_ini = 926.697 uV, v_off_fin = 932.525 uV 15:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.776 uVs 15:35:08 Integrated Voltage Measurement... 15:35:17 Voltage Offset Correction: v_off_ini = 927.251 uV, v_off_fin = 940.443 uV 15:35:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.385 uVs 15:35:17 Integrated Voltage Measurement... 15:35:26 Voltage Offset Correction: v_off_ini = 917.259 uV, v_off_fin = 907.260 uV 15:35:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.171 uVs 15:35:26 Integrated Voltage Measurement... 15:35:35 Voltage Offset Correction: v_off_ini = 912.690 uV, v_off_fin = 928.737 uV 15:35:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.470 uVs 15:35:35 Integrated Voltage Measurement... 15:35:44 Voltage Offset Correction: v_off_ini = 918.539 uV, v_off_fin = 907.227 uV 15:35:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.813 uVs 15:35:44 Integrated Voltage Measurement... 15:35:53 Voltage Offset Correction: v_off_ini = 909.324 uV, v_off_fin = 928.654 uV 15:35:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.335 uVs 15:35:57 I1Y Average and RMS of Measurements VT = -222.325 +- 5.074 uVs I1Y = -44.464 +- 1.015 uTm 15:36:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:36:03 Integrated Voltage Measurement... 15:36:11 Voltage Offset Correction: v_off_ini = 903.019 uV, v_off_fin = 906.770 uV 15:36:12 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -144.320 uVs 15:36:12 Integrated Voltage Measurement... 15:36:21 Voltage Offset Correction: v_off_ini = 918.697 uV, v_off_fin = 937.508 uV 15:36:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.601 uVs 15:36:21 Integrated Voltage Measurement... 15:36:30 Voltage Offset Correction: v_off_ini = 945.091 uV, v_off_fin = 911.535 uV 15:36:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.439 uVs 15:36:30 Integrated Voltage Measurement... 15:36:39 Voltage Offset Correction: v_off_ini = 911.310 uV, v_off_fin = 927.577 uV 15:36:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.519 uVs 15:36:39 Integrated Voltage Measurement... 15:36:48 Voltage Offset Correction: v_off_ini = 934.110 uV, v_off_fin = 916.385 uV 15:36:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.846 uVs 15:36:48 Integrated Voltage Measurement... 15:36:57 Voltage Offset Correction: v_off_ini = 923.358 uV, v_off_fin = 926.110 uV 15:36:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.926 uVs 15:36:59 I2X Average and RMS of Measurements VT = -134.941 +- 6.367 uVs I2X = 12.414 +- 0.585 uTm^2 15:37:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:37:04 Integrated Voltage Measurement... 15:37:13 Voltage Offset Correction: v_off_ini = 918.514 uV, v_off_fin = 934.581 uV 15:37:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.887 uVs 15:37:13 Integrated Voltage Measurement... 15:37:22 Voltage Offset Correction: v_off_ini = 922.750 uV, v_off_fin = 909.739 uV 15:37:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.932 uVs 15:37:22 Integrated Voltage Measurement... 15:37:31 Voltage Offset Correction: v_off_ini = 911.569 uV, v_off_fin = 911.084 uV 15:37:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.179 uVs 15:37:31 Integrated Voltage Measurement... 15:37:40 Voltage Offset Correction: v_off_ini = 915.890 uV, v_off_fin = 921.123 uV 15:37:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.140 uVs 15:37:40 Integrated Voltage Measurement... 15:37:49 Voltage Offset Correction: v_off_ini = 912.914 uV, v_off_fin = 915.575 uV 15:37:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.216 uVs 15:37:49 Integrated Voltage Measurement... 15:37:58 Voltage Offset Correction: v_off_ini = 904.640 uV, v_off_fin = 902.081 uV 15:37:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.974 uVs 15:38:01 I2Y Average and RMS of Measurements VT = -234.555 +- 2.378 uVs I2Y = -21.579 +- 0.219 uTm^2 15:38:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:38:09 Integrated Voltage Measurement... 15:38:18 Voltage Offset Correction: v_off_ini = 908.197 uV, v_off_fin = 913.627 uV 15:38:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.159 uVs 15:38:18 Integrated Voltage Measurement... 15:38:27 Voltage Offset Correction: v_off_ini = 898.821 uV, v_off_fin = 877.166 uV 15:38:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.038 uVs 15:38:27 Integrated Voltage Measurement... 15:38:36 Voltage Offset Correction: v_off_ini = 887.916 uV, v_off_fin = 880.239 uV 15:38:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.149 uVs 15:38:36 Integrated Voltage Measurement... 15:38:45 Voltage Offset Correction: v_off_ini = 874.599 uV, v_off_fin = 886.233 uV 15:38:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.255 uVs 15:38:45 Integrated Voltage Measurement... 15:38:54 Voltage Offset Correction: v_off_ini = 892.090 uV, v_off_fin = 874.837 uV 15:38:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.816 uVs 15:38:54 Integrated Voltage Measurement... 15:39:03 Voltage Offset Correction: v_off_ini = 869.085 uV, v_off_fin = 881.644 uV 15:39:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.725 uVs 15:39:07 I1X Average and RMS of Measurements VT = -127.857 +- 2.204 uVs I1X = 25.572 +- 0.441 uTm 15:39:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:39:14 Integrated Voltage Measurement... 15:39:23 Voltage Offset Correction: v_off_ini = 902.416 uV, v_off_fin = 877.452 uV 15:39:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.075 uVs 15:39:23 Integrated Voltage Measurement... 15:39:32 Voltage Offset Correction: v_off_ini = 895.437 uV, v_off_fin = 891.874 uV 15:39:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.639 uVs 15:39:32 Integrated Voltage Measurement... 15:39:41 Voltage Offset Correction: v_off_ini = 875.413 uV, v_off_fin = 882.100 uV 15:39:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -240.839 uVs 15:39:41 Integrated Voltage Measurement... 15:39:50 Voltage Offset Correction: v_off_ini = 900.527 uV, v_off_fin = 909.097 uV 15:39:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.642 uVs 15:39:50 Integrated Voltage Measurement... 15:39:59 Voltage Offset Correction: v_off_ini = 890.581 uV, v_off_fin = 865.458 uV 15:39:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.645 uVs 15:39:59 Integrated Voltage Measurement... 15:40:08 Voltage Offset Correction: v_off_ini = 885.346 uV, v_off_fin = 896.511 uV 15:40:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.260 uVs 15:40:12 I1Y Average and RMS of Measurements VT = -226.517 +- 4.184 uVs I1Y = -45.301 +- 0.836 uTm 15:40:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:40:17 Integrated Voltage Measurement... 15:40:26 Voltage Offset Correction: v_off_ini = 875.167 uV, v_off_fin = 883.510 uV 15:40:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.155 uVs 15:40:26 Integrated Voltage Measurement... 15:40:35 Voltage Offset Correction: v_off_ini = 911.810 uV, v_off_fin = 896.837 uV 15:40:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.422 uVs 15:40:35 Integrated Voltage Measurement... 15:40:44 Voltage Offset Correction: v_off_ini = 896.925 uV, v_off_fin = 875.750 uV 15:40:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.977 uVs 15:40:44 Integrated Voltage Measurement... 15:40:53 Voltage Offset Correction: v_off_ini = 882.865 uV, v_off_fin = 894.089 uV 15:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.750 uVs 15:40:53 Integrated Voltage Measurement... 15:41:02 Voltage Offset Correction: v_off_ini = 888.138 uV, v_off_fin = 874.904 uV 15:41:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.826 uVs 15:41:02 Integrated Voltage Measurement... 15:41:11 Voltage Offset Correction: v_off_ini = 862.984 uV, v_off_fin = 873.886 uV 15:41:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.839 uVs 15:41:14 I2X Average and RMS of Measurements VT = -123.162 +- 3.972 uVs I2X = 11.331 +- 0.365 uTm^2 15:41:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:41:19 Integrated Voltage Measurement... 15:41:28 Voltage Offset Correction: v_off_ini = 873.951 uV, v_off_fin = 883.216 uV 15:41:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.405 uVs 15:41:28 Integrated Voltage Measurement... 15:41:37 Voltage Offset Correction: v_off_ini = 877.193 uV, v_off_fin = 868.107 uV 15:41:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.714 uVs 15:41:37 Integrated Voltage Measurement... 15:41:46 Voltage Offset Correction: v_off_ini = 881.311 uV, v_off_fin = 871.696 uV 15:41:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.436 uVs 15:41:46 Integrated Voltage Measurement... 15:41:55 Voltage Offset Correction: v_off_ini = 869.593 uV, v_off_fin = 871.301 uV 15:41:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.088 uVs 15:41:55 Integrated Voltage Measurement... 15:42:04 Voltage Offset Correction: v_off_ini = 873.631 uV, v_off_fin = 879.445 uV 15:42:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.076 uVs 15:42:04 Integrated Voltage Measurement... 15:42:13 Voltage Offset Correction: v_off_ini = 878.191 uV, v_off_fin = 885.344 uV 15:42:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 220.307 uVs 15:42:15 I2Y Average and RMS of Measurements VT = -232.004 +- 6.685 uVs I2Y = -21.345 +- 0.615 uTm^2 15:42:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:42:50 Integrated Voltage Measurement... 15:42:59 Voltage Offset Correction: v_off_ini = 887.759 uV, v_off_fin = 874.261 uV 15:42:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.268 uVs 15:42:59 Integrated Voltage Measurement... 15:43:08 Voltage Offset Correction: v_off_ini = 882.082 uV, v_off_fin = 876.166 uV 15:43:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.090 uVs 15:43:08 Integrated Voltage Measurement... 15:43:17 Voltage Offset Correction: v_off_ini = 881.267 uV, v_off_fin = 879.834 uV 15:43:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.492 uVs 15:43:17 Integrated Voltage Measurement... 15:43:26 Voltage Offset Correction: v_off_ini = 857.734 uV, v_off_fin = 878.579 uV 15:43:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.002 uVs 15:43:26 Integrated Voltage Measurement... 15:43:35 Voltage Offset Correction: v_off_ini = 887.686 uV, v_off_fin = 889.080 uV 15:43:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.661 uVs 15:43:35 Integrated Voltage Measurement... 15:43:44 Voltage Offset Correction: v_off_ini = 878.240 uV, v_off_fin = 873.298 uV 15:43:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.794 uVs 15:43:48 I1X Average and RMS of Measurements VT = -127.718 +- 13.524 uVs I1X = 25.544 +- 2.705 uTm 15:43:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:43:55 Integrated Voltage Measurement... 15:44:04 Voltage Offset Correction: v_off_ini = 884.237 uV, v_off_fin = 880.377 uV 15:44:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.206 uVs 15:44:04 Integrated Voltage Measurement... 15:44:13 Voltage Offset Correction: v_off_ini = 885.171 uV, v_off_fin = 899.499 uV 15:44:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.787 uVs 15:44:13 Integrated Voltage Measurement... 15:44:22 Voltage Offset Correction: v_off_ini = 881.147 uV, v_off_fin = 884.676 uV 15:44:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.712 uVs 15:44:22 Integrated Voltage Measurement... 15:44:31 Voltage Offset Correction: v_off_ini = 888.610 uV, v_off_fin = 883.804 uV 15:44:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.938 uVs 15:44:31 Integrated Voltage Measurement... 15:44:40 Voltage Offset Correction: v_off_ini = 864.563 uV, v_off_fin = 862.787 uV 15:44:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.777 uVs 15:44:40 Integrated Voltage Measurement... 15:44:49 Voltage Offset Correction: v_off_ini = 892.954 uV, v_off_fin = 869.520 uV 15:44:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.078 uVs 15:44:53 I1Y Average and RMS of Measurements VT = -240.750 +- 1.608 uVs I1Y = -48.150 +- 0.322 uTm 15:44:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:45:01 Integrated Voltage Measurement... 15:45:10 Voltage Offset Correction: v_off_ini = 889.701 uV, v_off_fin = 893.141 uV 15:45:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.122 uVs 15:45:10 Integrated Voltage Measurement... 15:45:19 Voltage Offset Correction: v_off_ini = 918.370 uV, v_off_fin = 910.680 uV 15:45:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.790 uVs 15:45:19 Integrated Voltage Measurement... 15:45:28 Voltage Offset Correction: v_off_ini = 887.845 uV, v_off_fin = 879.973 uV 15:45:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.016 uVs 15:45:28 Integrated Voltage Measurement... 15:45:37 Voltage Offset Correction: v_off_ini = 894.275 uV, v_off_fin = 898.945 uV 15:45:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.435 uVs 15:45:37 Integrated Voltage Measurement... 15:45:46 Voltage Offset Correction: v_off_ini = 893.511 uV, v_off_fin = 880.758 uV 15:45:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.620 uVs 15:45:46 Integrated Voltage Measurement... 15:45:55 Voltage Offset Correction: v_off_ini = 868.364 uV, v_off_fin = 889.437 uV 15:45:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.950 uVs 15:45:58 I2X Average and RMS of Measurements VT = -135.822 +- 2.917 uVs I2X = 12.496 +- 0.268 uTm^2 15:46:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:46:05 Integrated Voltage Measurement... 15:46:14 Voltage Offset Correction: v_off_ini = 876.106 uV, v_off_fin = 868.392 uV 15:46:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.043 uVs 15:46:14 Integrated Voltage Measurement... 15:46:23 Voltage Offset Correction: v_off_ini = 895.111 uV, v_off_fin = 889.487 uV 15:46:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.674 uVs 15:46:23 Integrated Voltage Measurement... 15:46:32 Voltage Offset Correction: v_off_ini = 895.652 uV, v_off_fin = 885.268 uV 15:46:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.695 uVs 15:46:32 Integrated Voltage Measurement... 15:46:41 Voltage Offset Correction: v_off_ini = 884.963 uV, v_off_fin = 901.629 uV 15:46:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.506 uVs 15:46:41 Integrated Voltage Measurement... 15:46:50 Voltage Offset Correction: v_off_ini = 891.682 uV, v_off_fin = 899.029 uV 15:46:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.977 uVs 15:46:50 Integrated Voltage Measurement... 15:46:59 Voltage Offset Correction: v_off_ini = 902.213 uV, v_off_fin = 910.270 uV 15:47:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.039 uVs 15:47:02 I2Y Average and RMS of Measurements VT = -248.489 +- 8.507 uVs I2Y = -22.861 +- 0.783 uTm^2 15:47:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:47:11 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = 899.567 uV, v_off_fin = 891.126 uV 15:47:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.309 uVs 15:47:20 Integrated Voltage Measurement... 15:47:29 Voltage Offset Correction: v_off_ini = 896.734 uV, v_off_fin = 891.823 uV 15:47:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.999 uVs 15:47:29 Integrated Voltage Measurement... 15:47:38 Voltage Offset Correction: v_off_ini = 882.878 uV, v_off_fin = 900.647 uV 15:47:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.887 uVs 15:47:38 Integrated Voltage Measurement... 15:47:47 Voltage Offset Correction: v_off_ini = 905.872 uV, v_off_fin = 899.583 uV 15:47:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.765 uVs 15:47:47 Integrated Voltage Measurement... 15:47:56 Voltage Offset Correction: v_off_ini = 918.965 uV, v_off_fin = 925.390 uV 15:47:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.879 uVs 15:47:56 Integrated Voltage Measurement... 15:48:05 Voltage Offset Correction: v_off_ini = 915.315 uV, v_off_fin = 923.255 uV 15:48:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.524 uVs 15:48:09 I1X Average and RMS of Measurements VT = -124.727 +- 8.500 uVs I1X = 24.945 +- 1.700 uTm 15:48:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:48:16 Integrated Voltage Measurement... 15:48:25 Voltage Offset Correction: v_off_ini = 928.855 uV, v_off_fin = 921.602 uV 15:48:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.776 uVs 15:48:25 Integrated Voltage Measurement... 15:48:34 Voltage Offset Correction: v_off_ini = 922.617 uV, v_off_fin = 939.745 uV 15:48:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.239 uVs 15:48:34 Integrated Voltage Measurement... 15:48:43 Voltage Offset Correction: v_off_ini = 929.441 uV, v_off_fin = 906.190 uV 15:48:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.456 uVs 15:48:43 Integrated Voltage Measurement... 15:48:52 Voltage Offset Correction: v_off_ini = 887.319 uV, v_off_fin = 917.157 uV 15:48:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.489 uVs 15:48:52 Integrated Voltage Measurement... 15:49:01 Voltage Offset Correction: v_off_ini = 917.125 uV, v_off_fin = 886.130 uV 15:49:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.370 uVs 15:49:01 Integrated Voltage Measurement... 15:49:10 Voltage Offset Correction: v_off_ini = 926.500 uV, v_off_fin = 929.107 uV 15:49:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 272.417 uVs 15:49:14 I1Y Average and RMS of Measurements VT = -248.624 +- 9.354 uVs I1Y = -49.725 +- 1.871 uTm 15:49:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:49:22 Integrated Voltage Measurement... 15:49:31 Voltage Offset Correction: v_off_ini = 918.162 uV, v_off_fin = 909.692 uV 15:49:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.199 uVs 15:49:31 Integrated Voltage Measurement... 15:49:40 Voltage Offset Correction: v_off_ini = 930.083 uV, v_off_fin = 941.740 uV 15:49:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.643 uVs 15:49:40 Integrated Voltage Measurement... 15:49:49 Voltage Offset Correction: v_off_ini = 927.830 uV, v_off_fin = 921.930 uV 15:49:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.175 uVs 15:49:49 Integrated Voltage Measurement... 15:49:58 Voltage Offset Correction: v_off_ini = 922.309 uV, v_off_fin = 935.561 uV 15:49:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.780 uVs 15:49:58 Integrated Voltage Measurement... 15:50:07 Voltage Offset Correction: v_off_ini = 909.112 uV, v_off_fin = 904.608 uV 15:50:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.285 uVs 15:50:07 Integrated Voltage Measurement... 15:50:16 Voltage Offset Correction: v_off_ini = 920.450 uV, v_off_fin = 922.328 uV 15:50:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.884 uVs 15:50:18 I2X Average and RMS of Measurements VT = -129.661 +- 3.772 uVs I2X = 11.929 +- 0.347 uTm^2 15:50:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:50:26 Integrated Voltage Measurement... 15:50:35 Voltage Offset Correction: v_off_ini = 907.453 uV, v_off_fin = 915.485 uV 15:50:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.493 uVs 15:50:35 Integrated Voltage Measurement... 15:50:44 Voltage Offset Correction: v_off_ini = 937.352 uV, v_off_fin = 934.231 uV 15:50:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.846 uVs 15:50:44 Integrated Voltage Measurement... 15:50:53 Voltage Offset Correction: v_off_ini = 918.820 uV, v_off_fin = 926.507 uV 15:50:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.518 uVs 15:50:53 Integrated Voltage Measurement... 15:51:02 Voltage Offset Correction: v_off_ini = 917.347 uV, v_off_fin = 914.776 uV 15:51:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.534 uVs 15:51:02 Integrated Voltage Measurement... 15:51:11 Voltage Offset Correction: v_off_ini = 923.221 uV, v_off_fin = 928.152 uV 15:51:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.843 uVs 15:51:11 Integrated Voltage Measurement... 15:51:20 Voltage Offset Correction: v_off_ini = 911.584 uV, v_off_fin = 932.397 uV 15:51:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.472 uVs 15:51:23 I2Y Average and RMS of Measurements VT = -252.784 +- 7.595 uVs I2Y = -23.256 +- 0.699 uTm^2 15:51:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:51:32 Integrated Voltage Measurement... 15:51:40 Voltage Offset Correction: v_off_ini = 962.186 uV, v_off_fin = 968.082 uV 15:51:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -144.467 uVs 15:51:41 Integrated Voltage Measurement... 15:51:50 Voltage Offset Correction: v_off_ini = 967.229 uV, v_off_fin = 957.924 uV 15:51:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.909 uVs 15:51:50 Integrated Voltage Measurement... 15:51:59 Voltage Offset Correction: v_off_ini = 949.194 uV, v_off_fin = 962.649 uV 15:51:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.563 uVs 15:51:59 Integrated Voltage Measurement... 15:52:08 Voltage Offset Correction: v_off_ini = 957.353 uV, v_off_fin = 936.871 uV 15:52:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.949 uVs 15:52:08 Integrated Voltage Measurement... 15:52:17 Voltage Offset Correction: v_off_ini = 938.905 uV, v_off_fin = 932.188 uV 15:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.220 uVs 15:52:17 Integrated Voltage Measurement... 15:52:26 Voltage Offset Correction: v_off_ini = 937.557 uV, v_off_fin = 939.634 uV 15:52:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.526 uVs 15:52:30 I1X Average and RMS of Measurements VT = -120.939 +- 6.562 uVs I1X = 24.189 +- 1.314 uTm 15:52:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:37 Integrated Voltage Measurement... 15:52:46 Voltage Offset Correction: v_off_ini = 945.037 uV, v_off_fin = 925.006 uV 15:52:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.620 uVs 15:52:46 Integrated Voltage Measurement... 15:52:55 Voltage Offset Correction: v_off_ini = 932.249 uV, v_off_fin = 939.917 uV 15:52:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.371 uVs 15:52:55 Integrated Voltage Measurement... 15:53:04 Voltage Offset Correction: v_off_ini = 917.657 uV, v_off_fin = 914.914 uV 15:53:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.489 uVs 15:53:04 Integrated Voltage Measurement... 15:53:13 Voltage Offset Correction: v_off_ini = 912.527 uV, v_off_fin = 937.939 uV 15:53:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.796 uVs 15:53:13 Integrated Voltage Measurement... 15:53:22 Voltage Offset Correction: v_off_ini = 936.782 uV, v_off_fin = 929.613 uV 15:53:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.594 uVs 15:53:22 Integrated Voltage Measurement... 15:53:31 Voltage Offset Correction: v_off_ini = 927.964 uV, v_off_fin = 944.694 uV 15:53:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.223 uVs 15:53:35 I1Y Average and RMS of Measurements VT = -242.349 +- 2.665 uVs I1Y = -48.470 +- 0.533 uTm 15:53:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:43 Integrated Voltage Measurement... 15:53:52 Voltage Offset Correction: v_off_ini = 922.067 uV, v_off_fin = 918.057 uV 15:53:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.506 uVs 15:53:52 Integrated Voltage Measurement... 15:54:01 Voltage Offset Correction: v_off_ini = 935.252 uV, v_off_fin = 937.602 uV 15:54:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.857 uVs 15:54:01 Integrated Voltage Measurement... 15:54:10 Voltage Offset Correction: v_off_ini = 927.924 uV, v_off_fin = 935.892 uV 15:54:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.381 uVs 15:54:10 Integrated Voltage Measurement... 15:54:19 Voltage Offset Correction: v_off_ini = 931.808 uV, v_off_fin = 928.181 uV 15:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.330 uVs 15:54:19 Integrated Voltage Measurement... 15:54:28 Voltage Offset Correction: v_off_ini = 936.623 uV, v_off_fin = 916.982 uV 15:54:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.674 uVs 15:54:28 Integrated Voltage Measurement... 15:54:37 Voltage Offset Correction: v_off_ini = 935.467 uV, v_off_fin = 937.503 uV 15:54:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.675 uVs 15:54:39 I2X Average and RMS of Measurements VT = -134.571 +- 2.252 uVs I2X = 12.380 +- 0.207 uTm^2 15:54:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:47 Integrated Voltage Measurement... 15:54:56 Voltage Offset Correction: v_off_ini = 957.055 uV, v_off_fin = 924.343 uV 15:54:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.772 uVs 15:54:56 Integrated Voltage Measurement... 15:55:05 Voltage Offset Correction: v_off_ini = 935.957 uV, v_off_fin = 942.929 uV 15:55:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.327 uVs 15:55:05 Integrated Voltage Measurement... 15:55:14 Voltage Offset Correction: v_off_ini = 947.729 uV, v_off_fin = 925.328 uV 15:55:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.215 uVs 15:55:14 Integrated Voltage Measurement... 15:55:23 Voltage Offset Correction: v_off_ini = 930.429 uV, v_off_fin = 931.091 uV 15:55:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.638 uVs 15:55:23 Integrated Voltage Measurement... 15:55:32 Voltage Offset Correction: v_off_ini = 936.730 uV, v_off_fin = 935.260 uV 15:55:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.562 uVs 15:55:32 Integrated Voltage Measurement... 15:55:41 Voltage Offset Correction: v_off_ini = 915.325 uV, v_off_fin = 924.445 uV 15:55:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.812 uVs 15:55:44 I2Y Average and RMS of Measurements VT = -251.554 +- 14.643 uVs I2Y = -23.143 +- 1.347 uTm^2 15:55:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:55:53 Integrated Voltage Measurement... 15:56:02 Voltage Offset Correction: v_off_ini = 940.116 uV, v_off_fin = 929.471 uV 15:56:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -119.240 uVs 15:56:02 Integrated Voltage Measurement... 15:56:11 Voltage Offset Correction: v_off_ini = 963.976 uV, v_off_fin = 957.746 uV 15:56:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.482 uVs 15:56:11 Integrated Voltage Measurement... 15:56:20 Voltage Offset Correction: v_off_ini = 974.621 uV, v_off_fin = 969.792 uV 15:56:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.141 uVs 15:56:20 Integrated Voltage Measurement... 15:56:29 Voltage Offset Correction: v_off_ini = 952.159 uV, v_off_fin = 958.675 uV 15:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.321 uVs 15:56:29 Integrated Voltage Measurement... 15:56:38 Voltage Offset Correction: v_off_ini = 954.246 uV, v_off_fin = 948.273 uV 15:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.171 uVs 15:56:38 Integrated Voltage Measurement... 15:56:47 Voltage Offset Correction: v_off_ini = 954.192 uV, v_off_fin = 953.825 uV 15:56:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.737 uVs 15:56:51 I1X Average and RMS of Measurements VT = -106.515 +- 1.785 uVs I1X = 21.303 +- 0.357 uTm 15:56:54 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:56:58 Integrated Voltage Measurement... 15:57:07 Voltage Offset Correction: v_off_ini = 931.603 uV, v_off_fin = 914.856 uV 15:57:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -255.459 uVs 15:57:07 Integrated Voltage Measurement... 15:57:16 Voltage Offset Correction: v_off_ini = 933.866 uV, v_off_fin = 938.580 uV 15:57:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.295 uVs 15:57:16 Integrated Voltage Measurement... 15:57:25 Voltage Offset Correction: v_off_ini = 944.438 uV, v_off_fin = 935.256 uV 15:57:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.917 uVs 15:57:25 Integrated Voltage Measurement... 15:57:34 Voltage Offset Correction: v_off_ini = 948.100 uV, v_off_fin = 969.798 uV 15:57:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.345 uVs 15:57:34 Integrated Voltage Measurement... 15:57:43 Voltage Offset Correction: v_off_ini = 949.400 uV, v_off_fin = 916.192 uV 15:57:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.368 uVs 15:57:43 Integrated Voltage Measurement... 15:57:52 Voltage Offset Correction: v_off_ini = 947.213 uV, v_off_fin = 947.423 uV 15:57:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.492 uVs 15:57:56 I1Y Average and RMS of Measurements VT = -253.813 +- 3.059 uVs I1Y = -50.763 +- 0.611 uTm 15:58:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:58:04 Integrated Voltage Measurement... 15:58:13 Voltage Offset Correction: v_off_ini = 958.448 uV, v_off_fin = 939.425 uV 15:58:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.319 uVs 15:58:13 Integrated Voltage Measurement... 15:58:22 Voltage Offset Correction: v_off_ini = 943.033 uV, v_off_fin = 949.387 uV 15:58:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.906 uVs 15:58:22 Integrated Voltage Measurement... 15:58:31 Voltage Offset Correction: v_off_ini = 936.706 uV, v_off_fin = 932.655 uV 15:58:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.895 uVs 15:58:31 Integrated Voltage Measurement... 15:58:40 Voltage Offset Correction: v_off_ini = 951.001 uV, v_off_fin = 954.887 uV 15:58:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.712 uVs 15:58:40 Integrated Voltage Measurement... 15:58:49 Voltage Offset Correction: v_off_ini = 937.634 uV, v_off_fin = 920.475 uV 15:58:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.538 uVs 15:58:49 Integrated Voltage Measurement... 15:58:58 Voltage Offset Correction: v_off_ini = 930.879 uV, v_off_fin = 923.993 uV 15:58:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.276 uVs 15:59:01 I2X Average and RMS of Measurements VT = -124.774 +- 11.233 uVs I2X = 11.479 +- 1.033 uTm^2 15:59:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:59:08 Integrated Voltage Measurement... 15:59:17 Voltage Offset Correction: v_off_ini = 926.457 uV, v_off_fin = 919.487 uV 15:59:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.624 uVs 15:59:17 Integrated Voltage Measurement... 15:59:26 Voltage Offset Correction: v_off_ini = 902.412 uV, v_off_fin = 914.084 uV 15:59:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.740 uVs 15:59:26 Integrated Voltage Measurement... 15:59:35 Voltage Offset Correction: v_off_ini = 925.052 uV, v_off_fin = 930.227 uV 15:59:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.795 uVs 15:59:35 Integrated Voltage Measurement... 15:59:44 Voltage Offset Correction: v_off_ini = 921.833 uV, v_off_fin = 936.838 uV 15:59:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.902 uVs 15:59:44 Integrated Voltage Measurement... 15:59:53 Voltage Offset Correction: v_off_ini = 947.496 uV, v_off_fin = 924.003 uV 15:59:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.550 uVs 15:59:54 Integrated Voltage Measurement... 16:00:03 Voltage Offset Correction: v_off_ini = 903.898 uV, v_off_fin = 906.449 uV 16:00:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.343 uVs 16:00:05 I2Y Average and RMS of Measurements VT = -257.326 +- 14.977 uVs I2Y = -23.674 +- 1.378 uTm^2 16:00:10 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:00:14 Integrated Voltage Measurement... 16:00:23 Voltage Offset Correction: v_off_ini = 910.732 uV, v_off_fin = 902.666 uV 16:00:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.134 uVs 16:00:23 Integrated Voltage Measurement... 16:00:32 Voltage Offset Correction: v_off_ini = 894.079 uV, v_off_fin = 915.744 uV 16:00:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.415 uVs 16:00:32 Integrated Voltage Measurement... 16:00:41 Voltage Offset Correction: v_off_ini = 922.144 uV, v_off_fin = 931.504 uV 16:00:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.786 uVs 16:00:41 Integrated Voltage Measurement... 16:00:50 Voltage Offset Correction: v_off_ini = 921.160 uV, v_off_fin = 929.177 uV 16:00:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.210 uVs 16:00:50 Integrated Voltage Measurement... 16:00:59 Voltage Offset Correction: v_off_ini = 909.013 uV, v_off_fin = 921.981 uV 16:00:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.923 uVs 16:00:59 Integrated Voltage Measurement... 16:01:08 Voltage Offset Correction: v_off_ini = 887.581 uV, v_off_fin = 924.128 uV 16:01:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.654 uVs 16:01:12 I1X Average and RMS of Measurements VT = -116.687 +- 9.077 uVs I1X = 23.338 +- 1.815 uTm 16:01:15 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:01:19 Integrated Voltage Measurement... 16:01:28 Voltage Offset Correction: v_off_ini = 913.326 uV, v_off_fin = 917.364 uV 16:01:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.785 uVs 16:01:28 Integrated Voltage Measurement... 16:01:37 Voltage Offset Correction: v_off_ini = 925.531 uV, v_off_fin = 930.469 uV 16:01:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.299 uVs 16:01:37 Integrated Voltage Measurement... 16:01:46 Voltage Offset Correction: v_off_ini = 922.260 uV, v_off_fin = 902.600 uV 16:01:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.114 uVs 16:01:46 Integrated Voltage Measurement... 16:01:55 Voltage Offset Correction: v_off_ini = 956.275 uV, v_off_fin = 970.875 uV 16:01:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.329 uVs 16:01:55 Integrated Voltage Measurement... 16:02:04 Voltage Offset Correction: v_off_ini = 937.142 uV, v_off_fin = 940.972 uV 16:02:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.592 uVs 16:02:04 Integrated Voltage Measurement... 16:02:13 Voltage Offset Correction: v_off_ini = 956.856 uV, v_off_fin = 957.656 uV 16:02:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.609 uVs 16:02:17 I1Y Average and RMS of Measurements VT = -257.455 +- 3.092 uVs I1Y = -51.491 +- 0.618 uTm 16:02:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:02:25 Integrated Voltage Measurement... 16:02:34 Voltage Offset Correction: v_off_ini = 915.970 uV, v_off_fin = 923.705 uV 16:02:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.607 uVs 16:02:34 Integrated Voltage Measurement... 16:02:43 Voltage Offset Correction: v_off_ini = 940.921 uV, v_off_fin = 932.600 uV 16:02:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.296 uVs 16:02:43 Integrated Voltage Measurement... 16:02:52 Voltage Offset Correction: v_off_ini = 928.407 uV, v_off_fin = 920.800 uV 16:02:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.580 uVs 16:02:52 Integrated Voltage Measurement... 16:03:01 Voltage Offset Correction: v_off_ini = 921.994 uV, v_off_fin = 942.501 uV 16:03:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.204 uVs 16:03:01 Integrated Voltage Measurement... 16:03:10 Voltage Offset Correction: v_off_ini = 937.787 uV, v_off_fin = 925.590 uV 16:03:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.931 uVs 16:03:10 Integrated Voltage Measurement... 16:03:19 Voltage Offset Correction: v_off_ini = 938.266 uV, v_off_fin = 942.820 uV 16:03:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.948 uVs 16:03:22 I2X Average and RMS of Measurements VT = -117.594 +- 6.353 uVs I2X = 10.819 +- 0.584 uTm^2 16:03:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:03:29 Integrated Voltage Measurement... 16:03:38 Voltage Offset Correction: v_off_ini = 930.399 uV, v_off_fin = 916.514 uV 16:03:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.452 uVs 16:03:38 Integrated Voltage Measurement... 16:03:47 Voltage Offset Correction: v_off_ini = 918.269 uV, v_off_fin = 876.597 uV 16:03:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.487 uVs 16:03:48 Integrated Voltage Measurement... 16:03:57 Voltage Offset Correction: v_off_ini = 887.220 uV, v_off_fin = 896.638 uV 16:03:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.043 uVs 16:03:57 Integrated Voltage Measurement... 16:04:06 Voltage Offset Correction: v_off_ini = 893.440 uV, v_off_fin = 892.586 uV 16:04:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.087 uVs 16:04:06 Integrated Voltage Measurement... 16:04:15 Voltage Offset Correction: v_off_ini = 874.511 uV, v_off_fin = 887.283 uV 16:04:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.586 uVs 16:04:15 Integrated Voltage Measurement... 16:04:24 Voltage Offset Correction: v_off_ini = 879.177 uV, v_off_fin = 872.441 uV 16:04:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.650 uVs 16:04:26 I2Y Average and RMS of Measurements VT = -249.051 +- 8.213 uVs I2Y = -22.913 +- 0.756 uTm^2 16:04:34 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:04:38 Integrated Voltage Measurement... 16:04:47 Voltage Offset Correction: v_off_ini = 908.370 uV, v_off_fin = 870.600 uV 16:04:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -122.250 uVs 16:04:47 Integrated Voltage Measurement... 16:04:56 Voltage Offset Correction: v_off_ini = 884.118 uV, v_off_fin = 873.595 uV 16:04:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.563 uVs 16:04:56 Integrated Voltage Measurement... 16:05:05 Voltage Offset Correction: v_off_ini = 884.192 uV, v_off_fin = 875.331 uV 16:05:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.412 uVs 16:05:05 Integrated Voltage Measurement... 16:05:14 Voltage Offset Correction: v_off_ini = 864.803 uV, v_off_fin = 859.277 uV 16:05:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.066 uVs 16:05:14 Integrated Voltage Measurement... 16:05:23 Voltage Offset Correction: v_off_ini = 873.903 uV, v_off_fin = 871.327 uV 16:05:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.466 uVs 16:05:23 Integrated Voltage Measurement... 16:05:32 Voltage Offset Correction: v_off_ini = 901.527 uV, v_off_fin = 885.894 uV 16:05:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.062 uVs 16:05:37 I1X Average and RMS of Measurements VT = -124.970 +- 15.255 uVs I1X = 24.994 +- 3.052 uTm 16:05:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:05:43 Integrated Voltage Measurement... 16:05:52 Voltage Offset Correction: v_off_ini = 892.262 uV, v_off_fin = 878.410 uV 16:05:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.709 uVs 16:05:52 Integrated Voltage Measurement... 16:06:01 Voltage Offset Correction: v_off_ini = 895.152 uV, v_off_fin = 897.326 uV 16:06:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.710 uVs 16:06:01 Integrated Voltage Measurement... 16:06:10 Voltage Offset Correction: v_off_ini = 880.186 uV, v_off_fin = 866.468 uV 16:06:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.022 uVs 16:06:10 Integrated Voltage Measurement... 16:06:19 Voltage Offset Correction: v_off_ini = 890.779 uV, v_off_fin = 908.001 uV 16:06:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.923 uVs 16:06:19 Integrated Voltage Measurement... 16:06:28 Voltage Offset Correction: v_off_ini = 895.945 uV, v_off_fin = 873.511 uV 16:06:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.523 uVs 16:06:28 Integrated Voltage Measurement... 16:06:37 Voltage Offset Correction: v_off_ini = 878.306 uV, v_off_fin = 893.455 uV 16:06:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.021 uVs 16:06:42 I1Y Average and RMS of Measurements VT = -245.485 +- 5.507 uVs I1Y = -49.097 +- 1.101 uTm 16:06:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:06:47 Integrated Voltage Measurement... 16:06:56 Voltage Offset Correction: v_off_ini = 877.708 uV, v_off_fin = 880.497 uV 16:06:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.059 uVs 16:06:56 Integrated Voltage Measurement... 16:07:05 Voltage Offset Correction: v_off_ini = 909.051 uV, v_off_fin = 906.729 uV 16:07:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.335 uVs 16:07:05 Integrated Voltage Measurement... 16:07:14 Voltage Offset Correction: v_off_ini = 900.334 uV, v_off_fin = 887.585 uV 16:07:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.430 uVs 16:07:14 Integrated Voltage Measurement... 16:07:23 Voltage Offset Correction: v_off_ini = 893.539 uV, v_off_fin = 888.056 uV 16:07:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.812 uVs 16:07:23 Integrated Voltage Measurement... 16:07:32 Voltage Offset Correction: v_off_ini = 898.948 uV, v_off_fin = 886.199 uV 16:07:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.170 uVs 16:07:32 Integrated Voltage Measurement... 16:07:41 Voltage Offset Correction: v_off_ini = 904.414 uV, v_off_fin = 897.209 uV 16:07:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.791 uVs 16:07:43 I2X Average and RMS of Measurements VT = -124.433 +- 7.718 uVs I2X = 11.448 +- 0.710 uTm^2 16:07:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:07:48 Integrated Voltage Measurement... 16:07:57 Voltage Offset Correction: v_off_ini = 905.688 uV, v_off_fin = 906.099 uV 16:07:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.405 uVs 16:07:58 Integrated Voltage Measurement... 16:08:07 Voltage Offset Correction: v_off_ini = 883.232 uV, v_off_fin = 905.086 uV 16:08:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.877 uVs 16:08:07 Integrated Voltage Measurement... 16:08:16 Voltage Offset Correction: v_off_ini = 885.623 uV, v_off_fin = 896.810 uV 16:08:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.754 uVs 16:08:16 Integrated Voltage Measurement... 16:08:25 Voltage Offset Correction: v_off_ini = 904.163 uV, v_off_fin = 907.426 uV 16:08:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.003 uVs 16:08:25 Integrated Voltage Measurement... 16:08:34 Voltage Offset Correction: v_off_ini = 906.416 uV, v_off_fin = 897.364 uV 16:08:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.932 uVs 16:08:34 Integrated Voltage Measurement... 16:08:43 Voltage Offset Correction: v_off_ini = 926.169 uV, v_off_fin = 937.814 uV 16:08:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.478 uVs 16:08:45 I2Y Average and RMS of Measurements VT = -262.908 +- 16.084 uVs I2Y = -24.188 +- 1.480 uTm^2 16:08:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:08:53 Integrated Voltage Measurement... 16:09:02 Voltage Offset Correction: v_off_ini = 902.863 uV, v_off_fin = 924.198 uV 16:09:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.168 uVs 16:09:03 Integrated Voltage Measurement... 16:09:11 Voltage Offset Correction: v_off_ini = 934.922 uV, v_off_fin = 918.105 uV 16:09:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.690 uVs 16:09:12 Integrated Voltage Measurement... 16:09:20 Voltage Offset Correction: v_off_ini = 921.949 uV, v_off_fin = 929.529 uV 16:09:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.649 uVs 16:09:21 Integrated Voltage Measurement... 16:09:30 Voltage Offset Correction: v_off_ini = 925.982 uV, v_off_fin = 932.225 uV 16:09:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.798 uVs 16:09:30 Integrated Voltage Measurement... 16:09:39 Voltage Offset Correction: v_off_ini = 915.605 uV, v_off_fin = 927.559 uV 16:09:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.211 uVs 16:09:39 Integrated Voltage Measurement... 16:09:48 Voltage Offset Correction: v_off_ini = 919.387 uV, v_off_fin = 920.031 uV 16:09:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.498 uVs 16:09:52 I1X Average and RMS of Measurements VT = -103.169 +- 0.766 uVs I1X = 20.634 +- 0.153 uTm 16:09:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:09:59 Integrated Voltage Measurement... 16:10:08 Voltage Offset Correction: v_off_ini = 938.074 uV, v_off_fin = 919.693 uV 16:10:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.550 uVs 16:10:08 Integrated Voltage Measurement... 16:10:17 Voltage Offset Correction: v_off_ini = 919.507 uV, v_off_fin = 933.017 uV 16:10:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.961 uVs 16:10:17 Integrated Voltage Measurement... 16:10:26 Voltage Offset Correction: v_off_ini = 931.111 uV, v_off_fin = 913.666 uV 16:10:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.586 uVs 16:10:26 Integrated Voltage Measurement... 16:10:35 Voltage Offset Correction: v_off_ini = 921.436 uV, v_off_fin = 942.143 uV 16:10:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.914 uVs 16:10:35 Integrated Voltage Measurement... 16:10:44 Voltage Offset Correction: v_off_ini = 930.617 uV, v_off_fin = 924.552 uV 16:10:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.370 uVs 16:10:44 Integrated Voltage Measurement... 16:10:53 Voltage Offset Correction: v_off_ini = 931.254 uV, v_off_fin = 943.272 uV 16:10:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.918 uVs 16:10:57 I1Y Average and RMS of Measurements VT = -253.050 +- 3.522 uVs I1Y = -50.611 +- 0.703 uTm 16:10:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:11:02 Integrated Voltage Measurement... 16:11:11 Voltage Offset Correction: v_off_ini = 923.009 uV, v_off_fin = 935.447 uV 16:11:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.453 uVs 16:11:11 Integrated Voltage Measurement... 16:11:20 Voltage Offset Correction: v_off_ini = 924.661 uV, v_off_fin = 920.424 uV 16:11:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.370 uVs 16:11:20 Integrated Voltage Measurement... 16:11:29 Voltage Offset Correction: v_off_ini = 931.247 uV, v_off_fin = 924.810 uV 16:11:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.955 uVs 16:11:29 Integrated Voltage Measurement... 16:11:38 Voltage Offset Correction: v_off_ini = 952.471 uV, v_off_fin = 934.589 uV 16:11:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.068 uVs 16:11:38 Integrated Voltage Measurement... 16:11:47 Voltage Offset Correction: v_off_ini = 932.740 uV, v_off_fin = 931.790 uV 16:11:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.445 uVs 16:11:47 Integrated Voltage Measurement... 16:11:56 Voltage Offset Correction: v_off_ini = 914.451 uV, v_off_fin = 924.122 uV 16:11:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.650 uVs 16:11:59 I2X Average and RMS of Measurements VT = -124.657 +- 9.673 uVs I2X = 11.468 +- 0.890 uTm^2 16:12:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:12:04 Integrated Voltage Measurement... 16:12:13 Voltage Offset Correction: v_off_ini = 922.322 uV, v_off_fin = 911.908 uV 16:12:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.413 uVs 16:12:13 Integrated Voltage Measurement... 16:12:22 Voltage Offset Correction: v_off_ini = 898.340 uV, v_off_fin = 922.016 uV 16:12:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.666 uVs 16:12:22 Integrated Voltage Measurement... 16:12:31 Voltage Offset Correction: v_off_ini = 923.848 uV, v_off_fin = 910.285 uV 16:12:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.285 uVs 16:12:31 Integrated Voltage Measurement... 16:12:40 Voltage Offset Correction: v_off_ini = 912.100 uV, v_off_fin = 922.856 uV 16:12:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.654 uVs 16:12:40 Integrated Voltage Measurement... 16:12:49 Voltage Offset Correction: v_off_ini = 902.102 uV, v_off_fin = 929.244 uV 16:12:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.098 uVs 16:12:49 Integrated Voltage Measurement... 16:12:58 Voltage Offset Correction: v_off_ini = 937.253 uV, v_off_fin = 933.048 uV 16:12:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.371 uVs 16:13:00 I2Y Average and RMS of Measurements VT = -263.081 +- 10.504 uVs I2Y = -24.203 +- 0.966 uTm^2 16:13:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:09 Integrated Voltage Measurement... 16:13:18 Voltage Offset Correction: v_off_ini = 910.192 uV, v_off_fin = 928.719 uV 16:13:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -133.563 uVs 16:13:18 Integrated Voltage Measurement... 16:13:27 Voltage Offset Correction: v_off_ini = 905.129 uV, v_off_fin = 901.617 uV 16:13:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.993 uVs 16:13:27 Integrated Voltage Measurement... 16:13:36 Voltage Offset Correction: v_off_ini = 905.820 uV, v_off_fin = 929.553 uV 16:13:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.845 uVs 16:13:36 Integrated Voltage Measurement... 16:13:45 Voltage Offset Correction: v_off_ini = 933.048 uV, v_off_fin = 911.816 uV 16:13:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.781 uVs 16:13:45 Integrated Voltage Measurement... 16:13:54 Voltage Offset Correction: v_off_ini = 918.823 uV, v_off_fin = 914.158 uV 16:13:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.888 uVs 16:13:54 Integrated Voltage Measurement... 16:14:03 Voltage Offset Correction: v_off_ini = 916.092 uV, v_off_fin = 913.884 uV 16:14:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.612 uVs 16:14:07 I1X Average and RMS of Measurements VT = -132.280 +- 2.666 uVs I1X = 26.457 +- 0.534 uTm 16:14:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:14 Integrated Voltage Measurement... 16:14:23 Voltage Offset Correction: v_off_ini = 920.609 uV, v_off_fin = 906.054 uV 16:14:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.239 uVs 16:14:23 Integrated Voltage Measurement... 16:14:32 Voltage Offset Correction: v_off_ini = 927.811 uV, v_off_fin = 937.268 uV 16:14:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.325 uVs 16:14:32 Integrated Voltage Measurement... 16:14:41 Voltage Offset Correction: v_off_ini = 913.232 uV, v_off_fin = 909.000 uV 16:14:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.278 uVs 16:14:41 Integrated Voltage Measurement... 16:14:50 Voltage Offset Correction: v_off_ini = 918.172 uV, v_off_fin = 939.598 uV 16:14:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.930 uVs 16:14:50 Integrated Voltage Measurement... 16:14:59 Voltage Offset Correction: v_off_ini = 925.968 uV, v_off_fin = 914.658 uV 16:14:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.673 uVs 16:14:59 Integrated Voltage Measurement... 16:15:08 Voltage Offset Correction: v_off_ini = 926.008 uV, v_off_fin = 940.721 uV 16:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.583 uVs 16:15:12 I1Y Average and RMS of Measurements VT = -243.838 +- 5.649 uVs I1Y = -48.768 +- 1.130 uTm 16:15:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:17 Integrated Voltage Measurement... 16:15:26 Voltage Offset Correction: v_off_ini = 906.165 uV, v_off_fin = 919.534 uV 16:15:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.711 uVs 16:15:26 Integrated Voltage Measurement... 16:15:35 Voltage Offset Correction: v_off_ini = 936.909 uV, v_off_fin = 946.272 uV 16:15:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.331 uVs 16:15:35 Integrated Voltage Measurement... 16:15:44 Voltage Offset Correction: v_off_ini = 934.125 uV, v_off_fin = 911.199 uV 16:15:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.469 uVs 16:15:44 Integrated Voltage Measurement... 16:15:53 Voltage Offset Correction: v_off_ini = 924.894 uV, v_off_fin = 944.194 uV 16:15:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.914 uVs 16:15:53 Integrated Voltage Measurement... 16:16:02 Voltage Offset Correction: v_off_ini = 943.532 uV, v_off_fin = 929.280 uV 16:16:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.272 uVs 16:16:03 Integrated Voltage Measurement... 16:16:11 Voltage Offset Correction: v_off_ini = 928.623 uV, v_off_fin = 944.220 uV 16:16:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.052 uVs 16:16:14 I2X Average and RMS of Measurements VT = -130.792 +- 4.292 uVs I2X = 12.033 +- 0.395 uTm^2 16:16:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:19 Integrated Voltage Measurement... 16:16:28 Voltage Offset Correction: v_off_ini = 947.844 uV, v_off_fin = 942.370 uV 16:16:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.219 uVs 16:16:28 Integrated Voltage Measurement... 16:16:37 Voltage Offset Correction: v_off_ini = 955.119 uV, v_off_fin = 951.899 uV 16:16:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.961 uVs 16:16:37 Integrated Voltage Measurement... 16:16:46 Voltage Offset Correction: v_off_ini = 931.433 uV, v_off_fin = 928.912 uV 16:16:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -248.484 uVs 16:16:46 Integrated Voltage Measurement... 16:16:55 Voltage Offset Correction: v_off_ini = 963.583 uV, v_off_fin = 956.609 uV 16:16:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.736 uVs 16:16:55 Integrated Voltage Measurement... 16:17:04 Voltage Offset Correction: v_off_ini = 961.312 uV, v_off_fin = 971.103 uV 16:17:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.099 uVs 16:17:04 Integrated Voltage Measurement... 16:17:13 Voltage Offset Correction: v_off_ini = 941.064 uV, v_off_fin = 948.565 uV 16:17:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.072 uVs 16:17:16 I2Y Average and RMS of Measurements VT = -249.762 +- 4.191 uVs I2Y = -22.978 +- 0.386 uTm^2 16:17:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:17:24 Integrated Voltage Measurement... 16:17:33 Voltage Offset Correction: v_off_ini = 930.993 uV, v_off_fin = 938.196 uV 16:17:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.285 uVs 16:17:33 Integrated Voltage Measurement... 16:17:42 Voltage Offset Correction: v_off_ini = 929.049 uV, v_off_fin = 926.951 uV 16:17:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.259 uVs 16:17:42 Integrated Voltage Measurement... 16:17:51 Voltage Offset Correction: v_off_ini = 935.404 uV, v_off_fin = 940.432 uV 16:17:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.732 uVs 16:17:51 Integrated Voltage Measurement... 16:18:00 Voltage Offset Correction: v_off_ini = 938.215 uV, v_off_fin = 939.063 uV 16:18:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.115 uVs 16:18:00 Integrated Voltage Measurement... 16:18:09 Voltage Offset Correction: v_off_ini = 927.058 uV, v_off_fin = 924.452 uV 16:18:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.028 uVs 16:18:09 Integrated Voltage Measurement... 16:18:18 Voltage Offset Correction: v_off_ini = 948.475 uV, v_off_fin = 933.590 uV 16:18:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.074 uVs 16:18:22 I1X Average and RMS of Measurements VT = -115.082 +- 8.518 uVs I1X = 23.016 +- 1.704 uTm 16:18:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:18:29 Integrated Voltage Measurement... 16:18:38 Voltage Offset Correction: v_off_ini = 931.706 uV, v_off_fin = 936.901 uV 16:18:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.278 uVs 16:18:38 Integrated Voltage Measurement... 16:18:47 Voltage Offset Correction: v_off_ini = 935.463 uV, v_off_fin = 939.468 uV 16:18:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.762 uVs 16:18:47 Integrated Voltage Measurement... 16:18:56 Voltage Offset Correction: v_off_ini = 929.141 uV, v_off_fin = 905.028 uV 16:18:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.386 uVs 16:18:56 Integrated Voltage Measurement... 16:19:05 Voltage Offset Correction: v_off_ini = 928.772 uV, v_off_fin = 942.543 uV 16:19:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.719 uVs 16:19:05 Integrated Voltage Measurement... 16:19:14 Voltage Offset Correction: v_off_ini = 937.095 uV, v_off_fin = 924.049 uV 16:19:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -249.101 uVs 16:19:14 Integrated Voltage Measurement... 16:19:23 Voltage Offset Correction: v_off_ini = 938.715 uV, v_off_fin = 945.187 uV 16:19:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.161 uVs 16:19:27 I1Y Average and RMS of Measurements VT = -245.235 +- 0.810 uVs I1Y = -49.045 +- 0.164 uTm 16:19:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:19:32 Integrated Voltage Measurement... 16:19:41 Voltage Offset Correction: v_off_ini = 937.812 uV, v_off_fin = 937.892 uV 16:19:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.398 uVs 16:19:42 Integrated Voltage Measurement... 16:19:51 Voltage Offset Correction: v_off_ini = 933.991 uV, v_off_fin = 931.296 uV 16:19:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.028 uVs 16:19:51 Integrated Voltage Measurement... 16:20:00 Voltage Offset Correction: v_off_ini = 928.866 uV, v_off_fin = 929.573 uV 16:20:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.011 uVs 16:20:00 Integrated Voltage Measurement... 16:20:09 Voltage Offset Correction: v_off_ini = 908.050 uV, v_off_fin = 940.394 uV 16:20:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.361 uVs 16:20:09 Integrated Voltage Measurement... 16:20:18 Voltage Offset Correction: v_off_ini = 948.117 uV, v_off_fin = 939.155 uV 16:20:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.059 uVs 16:20:18 Integrated Voltage Measurement... 16:20:27 Voltage Offset Correction: v_off_ini = 949.342 uV, v_off_fin = 960.826 uV 16:20:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.730 uVs 16:20:29 I2X Average and RMS of Measurements VT = -129.098 +- 5.735 uVs I2X = 11.877 +- 0.528 uTm^2 16:20:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:20:34 Integrated Voltage Measurement... 16:20:43 Voltage Offset Correction: v_off_ini = 936.313 uV, v_off_fin = 946.132 uV 16:20:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -142.673 uVs 16:20:43 Integrated Voltage Measurement... 16:20:52 Voltage Offset Correction: v_off_ini = 949.831 uV, v_off_fin = 936.335 uV 16:20:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.472 uVs 16:20:52 Integrated Voltage Measurement... 16:21:01 Voltage Offset Correction: v_off_ini = 932.121 uV, v_off_fin = 931.776 uV 16:21:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.528 uVs 16:21:01 Integrated Voltage Measurement... 16:21:10 Voltage Offset Correction: v_off_ini = 921.262 uV, v_off_fin = 931.740 uV 16:21:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.080 uVs 16:21:10 Integrated Voltage Measurement... 16:21:19 Voltage Offset Correction: v_off_ini = 939.954 uV, v_off_fin = 933.556 uV 16:21:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -269.219 uVs 16:21:19 Integrated Voltage Measurement... 16:21:28 Voltage Offset Correction: v_off_ini = 923.741 uV, v_off_fin = 929.142 uV 16:21:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.480 uVs 16:21:31 I2Y Average and RMS of Measurements VT = -236.242 +- 30.287 uVs I2Y = -21.735 +- 2.787 uTm^2 16:21:35 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:21:39 Integrated Voltage Measurement... 16:21:48 Voltage Offset Correction: v_off_ini = 940.239 uV, v_off_fin = 932.758 uV 16:21:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.004 uVs 16:21:48 Integrated Voltage Measurement... 16:21:57 Voltage Offset Correction: v_off_ini = 907.131 uV, v_off_fin = 898.490 uV 16:21:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.813 uVs 16:21:57 Integrated Voltage Measurement... 16:22:06 Voltage Offset Correction: v_off_ini = 919.505 uV, v_off_fin = 923.899 uV 16:22:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.482 uVs 16:22:06 Integrated Voltage Measurement... 16:22:15 Voltage Offset Correction: v_off_ini = 918.849 uV, v_off_fin = 914.804 uV 16:22:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.532 uVs 16:22:15 Integrated Voltage Measurement... 16:22:24 Voltage Offset Correction: v_off_ini = 923.295 uV, v_off_fin = 927.672 uV 16:22:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.668 uVs 16:22:24 Integrated Voltage Measurement... 16:22:33 Voltage Offset Correction: v_off_ini = 925.746 uV, v_off_fin = 918.090 uV 16:22:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.892 uVs 16:22:37 I1X Average and RMS of Measurements VT = -114.399 +- 5.558 uVs I1X = 22.880 +- 1.111 uTm 16:22:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:22:44 Integrated Voltage Measurement... 16:22:53 Voltage Offset Correction: v_off_ini = 917.524 uV, v_off_fin = 905.453 uV 16:22:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.596 uVs 16:22:53 Integrated Voltage Measurement... 16:23:02 Voltage Offset Correction: v_off_ini = 912.547 uV, v_off_fin = 940.935 uV 16:23:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 259.139 uVs 16:23:02 Integrated Voltage Measurement... 16:23:11 Voltage Offset Correction: v_off_ini = 921.860 uV, v_off_fin = 901.826 uV 16:23:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.799 uVs 16:23:11 Integrated Voltage Measurement... 16:23:20 Voltage Offset Correction: v_off_ini = 900.837 uV, v_off_fin = 905.014 uV 16:23:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.062 uVs 16:23:20 Integrated Voltage Measurement... 16:23:29 Voltage Offset Correction: v_off_ini = 912.037 uV, v_off_fin = 903.559 uV 16:23:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -256.675 uVs 16:23:29 Integrated Voltage Measurement... 16:23:38 Voltage Offset Correction: v_off_ini = 921.575 uV, v_off_fin = 947.433 uV 16:23:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 254.780 uVs 16:23:42 I1Y Average and RMS of Measurements VT = -249.842 +- 18.812 uVs I1Y = -49.963 +- 3.763 uTm 16:23:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:23:47 Integrated Voltage Measurement... 16:23:56 Voltage Offset Correction: v_off_ini = 918.556 uV, v_off_fin = 907.546 uV 16:23:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.694 uVs 16:23:56 Integrated Voltage Measurement... 16:24:05 Voltage Offset Correction: v_off_ini = 921.373 uV, v_off_fin = 926.306 uV 16:24:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.924 uVs 16:24:06 Integrated Voltage Measurement... 16:24:15 Voltage Offset Correction: v_off_ini = 920.126 uV, v_off_fin = 896.709 uV 16:24:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.074 uVs 16:24:15 Integrated Voltage Measurement... 16:24:24 Voltage Offset Correction: v_off_ini = 912.255 uV, v_off_fin = 897.692 uV 16:24:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.083 uVs 16:24:24 Integrated Voltage Measurement... 16:24:33 Voltage Offset Correction: v_off_ini = 913.382 uV, v_off_fin = 899.826 uV 16:24:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.894 uVs 16:24:33 Integrated Voltage Measurement... 16:24:42 Voltage Offset Correction: v_off_ini = 908.788 uV, v_off_fin = 928.186 uV 16:24:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.370 uVs 16:24:44 I2X Average and RMS of Measurements VT = -124.340 +- 8.737 uVs I2X = 11.439 +- 0.804 uTm^2 16:24:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:24:49 Integrated Voltage Measurement... 16:24:58 Voltage Offset Correction: v_off_ini = 917.219 uV, v_off_fin = 923.825 uV 16:24:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.336 uVs 16:24:58 Integrated Voltage Measurement... 16:25:07 Voltage Offset Correction: v_off_ini = 913.735 uV, v_off_fin = 910.845 uV 16:25:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.380 uVs 16:25:07 Integrated Voltage Measurement... 16:25:16 Voltage Offset Correction: v_off_ini = 909.116 uV, v_off_fin = 911.384 uV 16:25:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.041 uVs 16:25:16 Integrated Voltage Measurement... 16:25:25 Voltage Offset Correction: v_off_ini = 911.726 uV, v_off_fin = 894.340 uV 16:25:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.178 uVs 16:25:25 Integrated Voltage Measurement... 16:25:34 Voltage Offset Correction: v_off_ini = 906.015 uV, v_off_fin = 905.245 uV 16:25:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.070 uVs 16:25:34 Integrated Voltage Measurement... 16:25:43 Voltage Offset Correction: v_off_ini = 885.280 uV, v_off_fin = 888.760 uV 16:25:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.852 uVs 16:25:46 I2Y Average and RMS of Measurements VT = -249.643 +- 6.501 uVs I2Y = -22.967 +- 0.598 uTm^2 16:25:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm