SLAC Magnetic Measurements Date: 02-19-2025 Time: 10:47:28 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10090 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 3 Measurement Device: Operator: YL Comment: 10:48:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:48:29 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:48:30 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:48:32 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:48:33 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:50:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:51:01 Integrated Voltage Measurement... 10:51:10 Voltage Offset Correction: v_off_ini = 408.985 uV, v_off_fin = 414.665 uV 10:51:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.631 uVs 10:51:10 Integrated Voltage Measurement... 10:51:19 Voltage Offset Correction: v_off_ini = 407.180 uV, v_off_fin = 412.623 uV 10:51:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.104 uVs 10:51:19 Integrated Voltage Measurement... 10:51:28 Voltage Offset Correction: v_off_ini = 409.005 uV, v_off_fin = 414.431 uV 10:51:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.860 uVs 10:51:28 Integrated Voltage Measurement... 10:51:37 Voltage Offset Correction: v_off_ini = 426.447 uV, v_off_fin = 421.772 uV 10:51:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.705 uVs 10:51:37 Integrated Voltage Measurement... 10:51:46 Voltage Offset Correction: v_off_ini = 395.446 uV, v_off_fin = 394.677 uV 10:51:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.481 uVs 10:51:46 Integrated Voltage Measurement... 10:51:55 Voltage Offset Correction: v_off_ini = 408.003 uV, v_off_fin = 406.327 uV 10:51:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.036 uVs 10:51:59 I1X Average and RMS of Measurements VT = -114.803 +- 1.789 uVs I1X = 22.961 +- 0.358 uTm 10:52:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:52:06 Integrated Voltage Measurement... 10:52:15 Voltage Offset Correction: v_off_ini = 395.806 uV, v_off_fin = 404.847 uV 10:52:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.509 uVs 10:52:15 Integrated Voltage Measurement... 10:52:24 Voltage Offset Correction: v_off_ini = 401.175 uV, v_off_fin = 414.489 uV 10:52:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.424 uVs 10:52:24 Integrated Voltage Measurement... 10:52:33 Voltage Offset Correction: v_off_ini = 412.376 uV, v_off_fin = 395.582 uV 10:52:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.674 uVs 10:52:33 Integrated Voltage Measurement... 10:52:42 Voltage Offset Correction: v_off_ini = 413.578 uV, v_off_fin = 417.378 uV 10:52:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.606 uVs 10:52:42 Integrated Voltage Measurement... 10:52:51 Voltage Offset Correction: v_off_ini = 416.519 uV, v_off_fin = 406.420 uV 10:52:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.804 uVs 10:52:51 Integrated Voltage Measurement... 10:53:00 Voltage Offset Correction: v_off_ini = 421.073 uV, v_off_fin = 422.035 uV 10:53:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.974 uVs 10:53:04 I1Y Average and RMS of Measurements VT = -225.665 +- 5.164 uVs I1Y = -45.134 +- 1.032 uTm 10:53:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:53:12 Integrated Voltage Measurement... 10:53:21 Voltage Offset Correction: v_off_ini = 409.303 uV, v_off_fin = 405.916 uV 10:53:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.196 uVs 10:53:21 Integrated Voltage Measurement... 10:53:30 Voltage Offset Correction: v_off_ini = 412.529 uV, v_off_fin = 418.665 uV 10:53:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.380 uVs 10:53:30 Integrated Voltage Measurement... 10:53:39 Voltage Offset Correction: v_off_ini = 427.014 uV, v_off_fin = 433.146 uV 10:53:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.449 uVs 10:53:39 Integrated Voltage Measurement... 10:53:48 Voltage Offset Correction: v_off_ini = 425.548 uV, v_off_fin = 414.293 uV 10:53:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.018 uVs 10:53:48 Integrated Voltage Measurement... 10:53:57 Voltage Offset Correction: v_off_ini = 407.808 uV, v_off_fin = 411.563 uV 10:53:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.954 uVs 10:53:57 Integrated Voltage Measurement... 10:54:06 Voltage Offset Correction: v_off_ini = 425.260 uV, v_off_fin = 421.038 uV 10:54:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.774 uVs 10:54:09 I2X Average and RMS of Measurements VT = -126.795 +- 5.630 uVs I2X = 11.665 +- 0.518 uTm^2 10:54:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:54:16 Integrated Voltage Measurement... 10:54:25 Voltage Offset Correction: v_off_ini = 411.492 uV, v_off_fin = 399.010 uV 10:54:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.923 uVs 10:54:25 Integrated Voltage Measurement... 10:54:34 Voltage Offset Correction: v_off_ini = 427.865 uV, v_off_fin = 427.103 uV 10:54:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.965 uVs 10:54:34 Integrated Voltage Measurement... 10:54:43 Voltage Offset Correction: v_off_ini = 433.721 uV, v_off_fin = 428.410 uV 10:54:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.592 uVs 10:54:44 Integrated Voltage Measurement... 10:54:52 Voltage Offset Correction: v_off_ini = 430.831 uV, v_off_fin = 416.918 uV 10:54:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.049 uVs 10:54:53 Integrated Voltage Measurement... 10:55:02 Voltage Offset Correction: v_off_ini = 402.517 uV, v_off_fin = 406.534 uV 10:55:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.222 uVs 10:55:02 Integrated Voltage Measurement... 10:55:11 Voltage Offset Correction: v_off_ini = 413.093 uV, v_off_fin = 414.208 uV 10:55:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.555 uVs 10:55:13 I2Y Average and RMS of Measurements VT = -220.218 +- 8.071 uVs I2Y = -20.260 +- 0.742 uTm^2 10:55:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:56:17 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm