SLAC Magnetic Measurements Date: 02-19-2025 Time: 10:47:28 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10090 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 3 Measurement Device: Operator: YL Comment: Parameters: Measurement Type = I12XY VS X VS GAP I1X dy = 0.5000 mm I1Y dx = 0.5000 mm I2X dy = 1.0000 mm I2Y dx = 1.0000 mm Wire # Turns = 1 Preamplifier Gain = 10000.00 Background Field Integrals: I1X = 19.0 (uTm) I1Y = -39.0 (uTm) I2X = 9.0 (uTm2) I2Y = -19.0 (uTm2) Subtracted from results Field Integrals: Gap (mm) X0 (mm) Y0 (mm) I1x (uTm) I1y (uTm) I2x (uTm^2) I2y (uTm^2) ---------- ---------- ---------- ---------------------- ---------------------- ---------------------- ---------------------- 0.000 0.000 0.000 3.961+- 0.358 -6.134+- 1.032 2.665+- 0.518 -1.260+- 0.742