SLAC Magnetic Measurements Date: 02-06-2025 Time: 17:03:25 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10089 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 2 Measurement Device: Operator: YL Comment: 17:03:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:35 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 17:03:37 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 17:03:38 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 17:03:40 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 17:03:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:54 Integrated Voltage Measurement... 17:04:03 Voltage Offset Correction: v_off_ini = 1912.858 uV, v_off_fin = 1921.004 uV 17:04:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 156.167 uVs 17:04:03 Integrated Voltage Measurement... 17:04:12 Voltage Offset Correction: v_off_ini = 1894.052 uV, v_off_fin = 1910.615 uV 17:04:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.822 uVs 17:04:12 Integrated Voltage Measurement... 17:04:21 Voltage Offset Correction: v_off_ini = 1927.058 uV, v_off_fin = 1908.944 uV 17:04:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 134.743 uVs 17:04:21 Integrated Voltage Measurement... 17:04:30 Voltage Offset Correction: v_off_ini = 1911.647 uV, v_off_fin = 1892.608 uV 17:04:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.656 uVs 17:04:30 Integrated Voltage Measurement... 17:04:39 Voltage Offset Correction: v_off_ini = 1926.589 uV, v_off_fin = 1948.289 uV 17:04:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.053 uVs 17:04:39 Integrated Voltage Measurement... 17:04:48 Voltage Offset Correction: v_off_ini = 1945.636 uV, v_off_fin = 1926.071 uV 17:04:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -147.440 uVs 17:04:52 I1X Average and RMS of Measurements VT = 157.314 +- 6.253 uVs I1X = -31.463 +- 1.251 uTm 17:04:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:04:59 Integrated Voltage Measurement... 17:05:08 Voltage Offset Correction: v_off_ini = 1902.932 uV, v_off_fin = 1943.715 uV 17:05:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -214.743 uVs 17:05:08 Integrated Voltage Measurement... 17:05:17 Voltage Offset Correction: v_off_ini = 1895.677 uV, v_off_fin = 1930.977 uV 17:05:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.212 uVs 17:05:17 Integrated Voltage Measurement... 17:05:26 Voltage Offset Correction: v_off_ini = 1931.969 uV, v_off_fin = 1873.621 uV 17:05:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.049 uVs 17:05:26 Integrated Voltage Measurement... 17:05:35 Voltage Offset Correction: v_off_ini = 1941.064 uV, v_off_fin = 1939.772 uV 17:05:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.999 uVs 17:05:35 Integrated Voltage Measurement... 17:05:44 Voltage Offset Correction: v_off_ini = 1945.937 uV, v_off_fin = 1950.075 uV 17:05:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.452 uVs 17:05:44 Integrated Voltage Measurement... 17:05:53 Voltage Offset Correction: v_off_ini = 1940.371 uV, v_off_fin = 1935.176 uV 17:05:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.375 uVs 17:05:57 I1Y Average and RMS of Measurements VT = -231.971 +- 7.405 uVs I1Y = -46.395 +- 1.480 uTm 17:06:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:06:05 Integrated Voltage Measurement... 17:06:14 Voltage Offset Correction: v_off_ini = 1899.733 uV, v_off_fin = 1895.143 uV 17:06:14 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = 145.219 uVs 17:06:14 Integrated Voltage Measurement... 17:06:23 Voltage Offset Correction: v_off_ini = 1937.871 uV, v_off_fin = 1960.760 uV 17:06:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -131.014 uVs 17:06:23 Integrated Voltage Measurement... 17:06:32 Voltage Offset Correction: v_off_ini = 1948.489 uV, v_off_fin = 1928.989 uV 17:06:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 144.842 uVs 17:06:32 Integrated Voltage Measurement... 17:06:41 Voltage Offset Correction: v_off_ini = 1924.239 uV, v_off_fin = 1970.318 uV 17:06:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -161.370 uVs 17:06:41 Integrated Voltage Measurement... 17:06:50 Voltage Offset Correction: v_off_ini = 1967.753 uV, v_off_fin = 1968.519 uV 17:06:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.148 uVs 17:06:50 Integrated Voltage Measurement... 17:06:59 Voltage Offset Correction: v_off_ini = 1952.683 uV, v_off_fin = 1955.157 uV 17:06:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.386 uVs 17:07:01 I2X Average and RMS of Measurements VT = 150.996 +- 9.770 uVs I2X = -13.891 +- 0.899 uTm^2 17:07:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:07:09 Integrated Voltage Measurement... 17:07:18 Voltage Offset Correction: v_off_ini = 1968.000 uV, v_off_fin = 1961.136 uV 17:07:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.857 uVs 17:07:18 Integrated Voltage Measurement... 17:07:27 Voltage Offset Correction: v_off_ini = 1959.882 uV, v_off_fin = 1963.095 uV 17:07:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.129 uVs 17:07:27 Integrated Voltage Measurement... 17:07:36 Voltage Offset Correction: v_off_ini = 1965.663 uV, v_off_fin = 1920.877 uV 17:07:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.267 uVs 17:07:36 Integrated Voltage Measurement... 17:07:45 Voltage Offset Correction: v_off_ini = 1949.549 uV, v_off_fin = 1944.320 uV 17:07:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.202 uVs 17:07:45 Integrated Voltage Measurement... 17:07:54 Voltage Offset Correction: v_off_ini = 1946.336 uV, v_off_fin = 1957.715 uV 17:07:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -338.095 uVs 17:07:54 Integrated Voltage Measurement... 17:08:03 Voltage Offset Correction: v_off_ini = 1958.630 uV, v_off_fin = 1945.531 uV 17:08:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 366.541 uVs 17:08:06 I2Y Average and RMS of Measurements VT = -341.515 +- 8.519 uVs I2Y = -31.419 +- 0.784 uTm^2 17:08:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:08:20 Integrated Voltage Measurement... 17:08:29 Voltage Offset Correction: v_off_ini = 1939.461 uV, v_off_fin = 1918.647 uV 17:08:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 178.346 uVs 17:08:29 Integrated Voltage Measurement... 17:08:38 Voltage Offset Correction: v_off_ini = 1946.424 uV, v_off_fin = 1946.167 uV 17:08:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -119.551 uVs 17:08:38 Integrated Voltage Measurement... 17:08:47 Voltage Offset Correction: v_off_ini = 1961.885 uV, v_off_fin = 1937.236 uV 17:08:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.761 uVs 17:08:47 Integrated Voltage Measurement... 17:08:56 Voltage Offset Correction: v_off_ini = 1962.262 uV, v_off_fin = 1949.321 uV 17:08:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.527 uVs 17:08:56 Integrated Voltage Measurement... 17:09:05 Voltage Offset Correction: v_off_ini = 1955.329 uV, v_off_fin = 1946.934 uV 17:09:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.326 uVs 17:09:05 Integrated Voltage Measurement... 17:09:14 Voltage Offset Correction: v_off_ini = 1947.328 uV, v_off_fin = 1961.967 uV 17:09:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.778 uVs 17:09:18 I1X Average and RMS of Measurements VT = 165.048 +- 13.353 uVs I1X = -33.010 +- 2.670 uTm 17:09:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:09:25 Integrated Voltage Measurement... 17:09:34 Voltage Offset Correction: v_off_ini = 1986.316 uV, v_off_fin = 2008.474 uV 17:09:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -243.719 uVs 17:09:34 Integrated Voltage Measurement... 17:09:42 Voltage Offset Correction: v_off_ini = 1999.434 uV, v_off_fin = 2017.868 uV 17:09:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.148 uVs 17:09:43 Integrated Voltage Measurement... 17:09:51 Voltage Offset Correction: v_off_ini = 2026.130 uV, v_off_fin = 1986.048 uV 17:09:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.706 uVs 17:09:52 Integrated Voltage Measurement... 17:10:00 Voltage Offset Correction: v_off_ini = 1978.741 uV, v_off_fin = 1983.729 uV 17:10:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.647 uVs 17:10:01 Integrated Voltage Measurement... 17:10:09 Voltage Offset Correction: v_off_ini = 1983.943 uV, v_off_fin = 1988.318 uV 17:10:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -295.752 uVs 17:10:10 Integrated Voltage Measurement... 17:10:18 Voltage Offset Correction: v_off_ini = 1965.864 uV, v_off_fin = 2011.854 uV 17:10:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.952 uVs 17:10:23 I1Y Average and RMS of Measurements VT = -242.321 +- 5.076 uVs I1Y = -48.465 +- 1.014 uTm 17:10:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:30 Integrated Voltage Measurement... 17:10:39 Voltage Offset Correction: v_off_ini = 2001.073 uV, v_off_fin = 1991.102 uV 17:10:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 133.646 uVs 17:10:39 Integrated Voltage Measurement... 17:10:48 Voltage Offset Correction: v_off_ini = 2013.975 uV, v_off_fin = 2008.370 uV 17:10:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -139.116 uVs 17:10:48 Integrated Voltage Measurement... 17:10:57 Voltage Offset Correction: v_off_ini = 2008.500 uV, v_off_fin = 1962.278 uV 17:10:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 132.385 uVs 17:10:57 Integrated Voltage Measurement... 17:11:06 Voltage Offset Correction: v_off_ini = 1979.700 uV, v_off_fin = 1974.494 uV 17:11:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -115.401 uVs 17:11:07 Integrated Voltage Measurement... 17:11:15 Voltage Offset Correction: v_off_ini = 2031.908 uV, v_off_fin = 1995.355 uV 17:11:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 133.313 uVs 17:11:16 Integrated Voltage Measurement... 17:11:25 Voltage Offset Correction: v_off_ini = 1971.299 uV, v_off_fin = 2011.772 uV 17:11:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -121.653 uVs 17:11:27 I2X Average and RMS of Measurements VT = 129.252 +- 5.249 uVs I2X = -11.891 +- 0.483 uTm^2 17:11:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:35 Integrated Voltage Measurement... 17:11:44 Voltage Offset Correction: v_off_ini = 2000.306 uV, v_off_fin = 1967.019 uV 17:11:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.292 uVs 17:11:44 Integrated Voltage Measurement... 17:11:53 Voltage Offset Correction: v_off_ini = 1979.661 uV, v_off_fin = 2008.606 uV 17:11:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.624 uVs 17:11:53 Integrated Voltage Measurement... 17:12:02 Voltage Offset Correction: v_off_ini = 1974.945 uV, v_off_fin = 2017.937 uV 17:12:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.720 uVs 17:12:02 Integrated Voltage Measurement... 17:12:11 Voltage Offset Correction: v_off_ini = 2006.336 uV, v_off_fin = 2011.010 uV 17:12:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.038 uVs 17:12:11 Integrated Voltage Measurement... 17:12:20 Voltage Offset Correction: v_off_ini = 1979.877 uV, v_off_fin = 1974.935 uV 17:12:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.418 uVs 17:12:20 Integrated Voltage Measurement... 17:12:29 Voltage Offset Correction: v_off_ini = 1980.536 uV, v_off_fin = 1990.870 uV 17:12:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.431 uVs 17:12:31 I2Y Average and RMS of Measurements VT = -339.754 +- 10.508 uVs I2Y = -31.257 +- 0.967 uTm^2 17:12:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:12:45 Integrated Voltage Measurement... 17:12:54 Voltage Offset Correction: v_off_ini = 2043.583 uV, v_off_fin = 1995.902 uV 17:12:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 144.770 uVs 17:12:54 Integrated Voltage Measurement... 17:13:03 Voltage Offset Correction: v_off_ini = 2005.427 uV, v_off_fin = 1989.114 uV 17:13:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.375 uVs 17:13:03 Integrated Voltage Measurement... 17:13:12 Voltage Offset Correction: v_off_ini = 1975.541 uV, v_off_fin = 1967.406 uV 17:13:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 122.327 uVs 17:13:12 Integrated Voltage Measurement... 17:13:21 Voltage Offset Correction: v_off_ini = 1986.953 uV, v_off_fin = 2040.396 uV 17:13:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -81.628 uVs 17:13:21 Integrated Voltage Measurement... 17:13:30 Voltage Offset Correction: v_off_ini = 2003.283 uV, v_off_fin = 2025.026 uV 17:13:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.151 uVs 17:13:30 Integrated Voltage Measurement... 17:13:39 Voltage Offset Correction: v_off_ini = 1994.248 uV, v_off_fin = 2026.017 uV 17:13:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.260 uVs 17:13:43 I1X Average and RMS of Measurements VT = 140.085 +- 27.137 uVs I1X = -28.018 +- 5.428 uTm 17:13:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:13:50 Integrated Voltage Measurement... 17:13:59 Voltage Offset Correction: v_off_ini = 2007.717 uV, v_off_fin = 2037.498 uV 17:13:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.634 uVs 17:13:59 Integrated Voltage Measurement... 17:14:08 Voltage Offset Correction: v_off_ini = 2030.504 uV, v_off_fin = 2003.482 uV 17:14:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.919 uVs 17:14:08 Integrated Voltage Measurement... 17:14:17 Voltage Offset Correction: v_off_ini = 1986.177 uV, v_off_fin = 1990.281 uV 17:14:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -235.740 uVs 17:14:17 Integrated Voltage Measurement... 17:14:26 Voltage Offset Correction: v_off_ini = 2014.409 uV, v_off_fin = 2032.858 uV 17:14:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.672 uVs 17:14:26 Integrated Voltage Measurement... 17:14:35 Voltage Offset Correction: v_off_ini = 2001.394 uV, v_off_fin = 2020.166 uV 17:14:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.892 uVs 17:14:35 Integrated Voltage Measurement... 17:14:44 Voltage Offset Correction: v_off_ini = 2014.480 uV, v_off_fin = 2026.956 uV 17:14:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.958 uVs 17:14:48 I1Y Average and RMS of Measurements VT = -230.469 +- 14.766 uVs I1Y = -46.092 +- 2.954 uTm 17:14:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:14:56 Integrated Voltage Measurement... 17:15:05 Voltage Offset Correction: v_off_ini = 2011.560 uV, v_off_fin = 1984.007 uV 17:15:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.336 uVs 17:15:05 Integrated Voltage Measurement... 17:15:14 Voltage Offset Correction: v_off_ini = 2007.229 uV, v_off_fin = 2021.203 uV 17:15:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.142 uVs 17:15:14 Integrated Voltage Measurement... 17:15:23 Voltage Offset Correction: v_off_ini = 2043.471 uV, v_off_fin = 2022.096 uV 17:15:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 144.687 uVs 17:15:23 Integrated Voltage Measurement... 17:15:32 Voltage Offset Correction: v_off_ini = 2018.960 uV, v_off_fin = 2014.304 uV 17:15:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.343 uVs 17:15:32 Integrated Voltage Measurement... 17:15:41 Voltage Offset Correction: v_off_ini = 2000.253 uV, v_off_fin = 1982.253 uV 17:15:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 150.476 uVs 17:15:41 Integrated Voltage Measurement... 17:15:50 Voltage Offset Correction: v_off_ini = 1988.874 uV, v_off_fin = 2004.114 uV 17:15:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -139.781 uVs 17:15:52 I2X Average and RMS of Measurements VT = 162.794 +- 22.972 uVs I2X = -14.977 +- 2.113 uTm^2 17:15:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:16:00 Integrated Voltage Measurement... 17:16:09 Voltage Offset Correction: v_off_ini = 1992.420 uV, v_off_fin = 1964.683 uV 17:16:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.294 uVs 17:16:09 Integrated Voltage Measurement... 17:16:18 Voltage Offset Correction: v_off_ini = 1977.809 uV, v_off_fin = 1968.084 uV 17:16:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 333.365 uVs 17:16:18 Integrated Voltage Measurement... 17:16:27 Voltage Offset Correction: v_off_ini = 2002.667 uV, v_off_fin = 2005.692 uV 17:16:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -354.597 uVs 17:16:27 Integrated Voltage Measurement... 17:16:36 Voltage Offset Correction: v_off_ini = 2026.361 uV, v_off_fin = 2001.725 uV 17:16:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 326.076 uVs 17:16:36 Integrated Voltage Measurement... 17:16:45 Voltage Offset Correction: v_off_ini = 1982.649 uV, v_off_fin = 2013.091 uV 17:16:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.677 uVs 17:16:45 Integrated Voltage Measurement... 17:16:54 Voltage Offset Correction: v_off_ini = 2044.069 uV, v_off_fin = 2002.578 uV 17:16:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.846 uVs 17:16:57 I2Y Average and RMS of Measurements VT = -331.643 +- 11.543 uVs I2Y = -30.511 +- 1.062 uTm^2 17:17:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:17:11 Integrated Voltage Measurement... 17:17:20 Voltage Offset Correction: v_off_ini = 1974.608 uV, v_off_fin = 1972.475 uV 17:17:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 118.524 uVs 17:17:20 Integrated Voltage Measurement... 17:17:29 Voltage Offset Correction: v_off_ini = 2005.828 uV, v_off_fin = 2025.574 uV 17:17:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.544 uVs 17:17:29 Integrated Voltage Measurement... 17:17:38 Voltage Offset Correction: v_off_ini = 1971.381 uV, v_off_fin = 1969.365 uV 17:17:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.394 uVs 17:17:38 Integrated Voltage Measurement... 17:17:47 Voltage Offset Correction: v_off_ini = 2016.388 uV, v_off_fin = 2038.641 uV 17:17:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.986 uVs 17:17:47 Integrated Voltage Measurement... 17:17:56 Voltage Offset Correction: v_off_ini = 2005.801 uV, v_off_fin = 1987.742 uV 17:17:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 89.863 uVs 17:17:56 Integrated Voltage Measurement... 17:18:05 Voltage Offset Correction: v_off_ini = 2006.943 uV, v_off_fin = 1993.530 uV 17:18:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.733 uVs 17:18:09 I1X Average and RMS of Measurements VT = 156.341 +- 17.890 uVs I1X = -31.269 +- 3.578 uTm 17:18:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:18:16 Integrated Voltage Measurement... 17:18:25 Voltage Offset Correction: v_off_ini = 1992.013 uV, v_off_fin = 1960.552 uV 17:18:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -262.300 uVs 17:18:25 Integrated Voltage Measurement... 17:18:34 Voltage Offset Correction: v_off_ini = 1966.925 uV, v_off_fin = 1965.225 uV 17:18:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.545 uVs 17:18:34 Integrated Voltage Measurement... 17:18:43 Voltage Offset Correction: v_off_ini = 1948.400 uV, v_off_fin = 1971.728 uV 17:18:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.821 uVs 17:18:43 Integrated Voltage Measurement... 17:18:52 Voltage Offset Correction: v_off_ini = 1989.291 uV, v_off_fin = 2022.264 uV 17:18:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.335 uVs 17:18:52 Integrated Voltage Measurement... 17:19:01 Voltage Offset Correction: v_off_ini = 1976.279 uV, v_off_fin = 1970.612 uV 17:19:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -227.729 uVs 17:19:01 Integrated Voltage Measurement... 17:19:10 Voltage Offset Correction: v_off_ini = 2019.637 uV, v_off_fin = 2021.508 uV 17:19:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 215.917 uVs 17:19:14 I1Y Average and RMS of Measurements VT = -235.441 +- 14.436 uVs I1Y = -47.086 +- 2.891 uTm 17:19:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:21 Integrated Voltage Measurement... 17:19:30 Voltage Offset Correction: v_off_ini = 1957.010 uV, v_off_fin = 2010.214 uV 17:19:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.358 uVs 17:19:30 Integrated Voltage Measurement... 17:19:39 Voltage Offset Correction: v_off_ini = 2006.023 uV, v_off_fin = 2009.332 uV 17:19:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -141.331 uVs 17:19:40 Integrated Voltage Measurement... 17:19:48 Voltage Offset Correction: v_off_ini = 1972.217 uV, v_off_fin = 2002.364 uV 17:19:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.135 uVs 17:19:49 Integrated Voltage Measurement... 17:19:58 Voltage Offset Correction: v_off_ini = 1991.374 uV, v_off_fin = 1983.923 uV 17:19:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -146.332 uVs 17:19:58 Integrated Voltage Measurement... 17:20:07 Voltage Offset Correction: v_off_ini = 1943.044 uV, v_off_fin = 1940.272 uV 17:20:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 136.237 uVs 17:20:07 Integrated Voltage Measurement... 17:20:16 Voltage Offset Correction: v_off_ini = 1954.661 uV, v_off_fin = 1941.405 uV 17:20:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -141.243 uVs 17:20:18 I2X Average and RMS of Measurements VT = 156.939 +- 14.361 uVs I2X = -14.438 +- 1.321 uTm^2 17:20:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:26 Integrated Voltage Measurement... 17:20:35 Voltage Offset Correction: v_off_ini = 1906.900 uV, v_off_fin = 1927.893 uV 17:20:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.560 uVs 17:20:35 Integrated Voltage Measurement... 17:20:44 Voltage Offset Correction: v_off_ini = 1940.822 uV, v_off_fin = 1914.285 uV 17:20:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.592 uVs 17:20:44 Integrated Voltage Measurement... 17:20:53 Voltage Offset Correction: v_off_ini = 1915.472 uV, v_off_fin = 1963.978 uV 17:20:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.317 uVs 17:20:53 Integrated Voltage Measurement... 17:21:02 Voltage Offset Correction: v_off_ini = 1925.651 uV, v_off_fin = 1939.484 uV 17:21:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.463 uVs 17:21:02 Integrated Voltage Measurement... 17:21:11 Voltage Offset Correction: v_off_ini = 1956.752 uV, v_off_fin = 1971.998 uV 17:21:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.930 uVs 17:21:11 Integrated Voltage Measurement... 17:21:20 Voltage Offset Correction: v_off_ini = 1936.810 uV, v_off_fin = 1934.798 uV 17:21:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.861 uVs 17:21:22 I2Y Average and RMS of Measurements VT = -318.954 +- 15.179 uVs I2Y = -29.344 +- 1.396 uTm^2 17:21:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:21:36 Integrated Voltage Measurement... 17:21:45 Voltage Offset Correction: v_off_ini = 1953.323 uV, v_off_fin = 1959.531 uV 17:21:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 183.728 uVs 17:21:45 Integrated Voltage Measurement... 17:21:54 Voltage Offset Correction: v_off_ini = 1950.878 uV, v_off_fin = 1943.791 uV 17:21:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.384 uVs 17:21:54 Integrated Voltage Measurement... 17:22:03 Voltage Offset Correction: v_off_ini = 1971.317 uV, v_off_fin = 1960.325 uV 17:22:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.197 uVs 17:22:03 Integrated Voltage Measurement... 17:22:12 Voltage Offset Correction: v_off_ini = 1944.686 uV, v_off_fin = 1892.642 uV 17:22:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.897 uVs 17:22:12 Integrated Voltage Measurement... 17:22:21 Voltage Offset Correction: v_off_ini = 1950.110 uV, v_off_fin = 1948.628 uV 17:22:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.680 uVs 17:22:21 Integrated Voltage Measurement... 17:22:30 Voltage Offset Correction: v_off_ini = 1927.314 uV, v_off_fin = 1952.978 uV 17:22:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.231 uVs 17:22:34 I1X Average and RMS of Measurements VT = 171.686 +- 8.824 uVs I1X = -34.338 +- 1.766 uTm 17:22:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:41 Integrated Voltage Measurement... 17:22:50 Voltage Offset Correction: v_off_ini = 1980.467 uV, v_off_fin = 1953.962 uV 17:22:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.433 uVs 17:22:50 Integrated Voltage Measurement... 17:22:59 Voltage Offset Correction: v_off_ini = 1967.303 uV, v_off_fin = 2020.325 uV 17:22:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.914 uVs 17:22:59 Integrated Voltage Measurement... 17:23:08 Voltage Offset Correction: v_off_ini = 1982.122 uV, v_off_fin = 1971.095 uV 17:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -213.385 uVs 17:23:08 Integrated Voltage Measurement... 17:23:17 Voltage Offset Correction: v_off_ini = 1932.855 uV, v_off_fin = 1985.683 uV 17:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 275.769 uVs 17:23:17 Integrated Voltage Measurement... 17:23:26 Voltage Offset Correction: v_off_ini = 1956.587 uV, v_off_fin = 1946.089 uV 17:23:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -249.662 uVs 17:23:26 Integrated Voltage Measurement... 17:23:35 Voltage Offset Correction: v_off_ini = 1949.452 uV, v_off_fin = 1976.501 uV 17:23:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 254.756 uVs 17:23:39 I1Y Average and RMS of Measurements VT = -235.986 +- 17.820 uVs I1Y = -47.190 +- 3.560 uTm 17:23:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:23:47 Integrated Voltage Measurement... 17:23:56 Voltage Offset Correction: v_off_ini = 1941.939 uV, v_off_fin = 1960.999 uV 17:23:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 160.922 uVs 17:23:56 Integrated Voltage Measurement... 17:24:05 Voltage Offset Correction: v_off_ini = 1988.274 uV, v_off_fin = 1965.631 uV 17:24:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -148.342 uVs 17:24:05 Integrated Voltage Measurement... 17:24:14 Voltage Offset Correction: v_off_ini = 1944.402 uV, v_off_fin = 1924.288 uV 17:24:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 150.695 uVs 17:24:14 Integrated Voltage Measurement... 17:24:23 Voltage Offset Correction: v_off_ini = 1995.233 uV, v_off_fin = 1988.486 uV 17:24:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.058 uVs 17:24:23 Integrated Voltage Measurement... 17:24:32 Voltage Offset Correction: v_off_ini = 1966.760 uV, v_off_fin = 1933.991 uV 17:24:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 142.006 uVs 17:24:32 Integrated Voltage Measurement... 17:24:41 Voltage Offset Correction: v_off_ini = 1921.871 uV, v_off_fin = 1978.810 uV 17:24:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -139.193 uVs 17:24:44 I2X Average and RMS of Measurements VT = 150.703 +- 7.203 uVs I2X = -13.865 +- 0.663 uTm^2 17:24:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:51 Integrated Voltage Measurement... 17:25:00 Voltage Offset Correction: v_off_ini = 2005.759 uV, v_off_fin = 1976.183 uV 17:25:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -368.394 uVs 17:25:00 Integrated Voltage Measurement... 17:25:09 Voltage Offset Correction: v_off_ini = 1967.841 uV, v_off_fin = 1978.976 uV 17:25:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.800 uVs 17:25:09 Integrated Voltage Measurement... 17:25:18 Voltage Offset Correction: v_off_ini = 2002.551 uV, v_off_fin = 1944.490 uV 17:25:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.395 uVs 17:25:18 Integrated Voltage Measurement... 17:25:27 Voltage Offset Correction: v_off_ini = 1953.711 uV, v_off_fin = 1970.595 uV 17:25:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.522 uVs 17:25:28 Integrated Voltage Measurement... 17:25:36 Voltage Offset Correction: v_off_ini = 1967.049 uV, v_off_fin = 1976.755 uV 17:25:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.602 uVs 17:25:37 Integrated Voltage Measurement... 17:25:46 Voltage Offset Correction: v_off_ini = 2010.554 uV, v_off_fin = 1979.326 uV 17:25:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.287 uVs 17:25:48 I2Y Average and RMS of Measurements VT = -343.500 +- 8.103 uVs I2Y = -31.603 +- 0.745 uTm^2 17:25:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:26:02 Integrated Voltage Measurement... 17:26:11 Voltage Offset Correction: v_off_ini = 1976.822 uV, v_off_fin = 1960.993 uV 17:26:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.997 uVs 17:26:11 Integrated Voltage Measurement... 17:26:20 Voltage Offset Correction: v_off_ini = 1972.804 uV, v_off_fin = 1974.206 uV 17:26:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -135.592 uVs 17:26:20 Integrated Voltage Measurement... 17:26:29 Voltage Offset Correction: v_off_ini = 1927.913 uV, v_off_fin = 1980.703 uV 17:26:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.399 uVs 17:26:29 Integrated Voltage Measurement... 17:26:38 Voltage Offset Correction: v_off_ini = 1997.003 uV, v_off_fin = 1991.553 uV 17:26:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.271 uVs 17:26:38 Integrated Voltage Measurement... 17:26:47 Voltage Offset Correction: v_off_ini = 1960.379 uV, v_off_fin = 1988.957 uV 17:26:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 129.967 uVs 17:26:47 Integrated Voltage Measurement... 17:26:56 Voltage Offset Correction: v_off_ini = 2004.425 uV, v_off_fin = 1960.816 uV 17:26:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -101.560 uVs 17:27:00 I1X Average and RMS of Measurements VT = 156.464 +- 30.541 uVs I1X = -31.293 +- 6.108 uTm 17:27:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:27:07 Integrated Voltage Measurement... 17:27:16 Voltage Offset Correction: v_off_ini = 1990.416 uV, v_off_fin = 1991.948 uV 17:27:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.233 uVs 17:27:16 Integrated Voltage Measurement... 17:27:25 Voltage Offset Correction: v_off_ini = 1983.892 uV, v_off_fin = 2034.156 uV 17:27:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.317 uVs 17:27:25 Integrated Voltage Measurement... 17:27:34 Voltage Offset Correction: v_off_ini = 1973.565 uV, v_off_fin = 1977.092 uV 17:27:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.150 uVs 17:27:34 Integrated Voltage Measurement... 17:27:43 Voltage Offset Correction: v_off_ini = 1975.865 uV, v_off_fin = 1982.524 uV 17:27:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 264.132 uVs 17:27:43 Integrated Voltage Measurement... 17:27:52 Voltage Offset Correction: v_off_ini = 2008.443 uV, v_off_fin = 1981.136 uV 17:27:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.574 uVs 17:27:52 Integrated Voltage Measurement... 17:28:01 Voltage Offset Correction: v_off_ini = 1971.105 uV, v_off_fin = 2027.703 uV 17:28:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.530 uVs 17:28:05 I1Y Average and RMS of Measurements VT = -245.823 +- 11.916 uVs I1Y = -49.162 +- 2.385 uTm 17:28:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:28:13 Integrated Voltage Measurement... 17:28:22 Voltage Offset Correction: v_off_ini = 1957.851 uV, v_off_fin = 1964.105 uV 17:28:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.011 uVs 17:28:22 Integrated Voltage Measurement... 17:28:31 Voltage Offset Correction: v_off_ini = 1989.038 uV, v_off_fin = 1983.707 uV 17:28:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.183 uVs 17:28:31 Integrated Voltage Measurement... 17:28:40 Voltage Offset Correction: v_off_ini = 2042.014 uV, v_off_fin = 2034.531 uV 17:28:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 142.934 uVs 17:28:40 Integrated Voltage Measurement... 17:28:49 Voltage Offset Correction: v_off_ini = 2021.913 uV, v_off_fin = 1986.868 uV 17:28:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -137.749 uVs 17:28:49 Integrated Voltage Measurement... 17:28:58 Voltage Offset Correction: v_off_ini = 2000.141 uV, v_off_fin = 1973.328 uV 17:28:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.572 uVs 17:28:58 Integrated Voltage Measurement... 17:29:07 Voltage Offset Correction: v_off_ini = 1999.656 uV, v_off_fin = 1993.532 uV 17:29:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -152.317 uVs 17:29:09 I2X Average and RMS of Measurements VT = 160.461 +- 15.681 uVs I2X = -14.762 +- 1.443 uTm^2 17:29:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:29:17 Integrated Voltage Measurement... 17:29:26 Voltage Offset Correction: v_off_ini = 2008.173 uV, v_off_fin = 2016.007 uV 17:29:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -360.519 uVs 17:29:26 Integrated Voltage Measurement... 17:29:35 Voltage Offset Correction: v_off_ini = 2003.832 uV, v_off_fin = 1997.923 uV 17:29:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.882 uVs 17:29:35 Integrated Voltage Measurement... 17:29:44 Voltage Offset Correction: v_off_ini = 1969.516 uV, v_off_fin = 1986.946 uV 17:29:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.966 uVs 17:29:44 Integrated Voltage Measurement... 17:29:53 Voltage Offset Correction: v_off_ini = 1953.444 uV, v_off_fin = 1951.460 uV 17:29:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.708 uVs 17:29:53 Integrated Voltage Measurement... 17:30:02 Voltage Offset Correction: v_off_ini = 1970.915 uV, v_off_fin = 1966.460 uV 17:30:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -389.979 uVs 17:30:02 Integrated Voltage Measurement... 17:30:11 Voltage Offset Correction: v_off_ini = 1971.018 uV, v_off_fin = 1948.609 uV 17:30:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.249 uVs 17:30:14 I2Y Average and RMS of Measurements VT = -346.217 +- 12.265 uVs I2Y = -31.852 +- 1.128 uTm^2 17:30:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:30:27 Integrated Voltage Measurement... 17:30:36 Voltage Offset Correction: v_off_ini = 1970.238 uV, v_off_fin = 1955.577 uV 17:30:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = 150.799 uVs 17:30:36 Integrated Voltage Measurement... 17:30:45 Voltage Offset Correction: v_off_ini = 1981.975 uV, v_off_fin = 1989.380 uV 17:30:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -152.411 uVs 17:30:46 Integrated Voltage Measurement... 17:30:54 Voltage Offset Correction: v_off_ini = 1963.925 uV, v_off_fin = 1983.958 uV 17:30:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 132.930 uVs 17:30:55 Integrated Voltage Measurement... 17:31:03 Voltage Offset Correction: v_off_ini = 1963.668 uV, v_off_fin = 1974.602 uV 17:31:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.870 uVs 17:31:04 Integrated Voltage Measurement... 17:31:12 Voltage Offset Correction: v_off_ini = 1971.999 uV, v_off_fin = 1975.175 uV 17:31:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.434 uVs 17:31:13 Integrated Voltage Measurement... 17:31:21 Voltage Offset Correction: v_off_ini = 1944.871 uV, v_off_fin = 1985.328 uV 17:31:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -128.627 uVs 17:31:26 I1X Average and RMS of Measurements VT = 154.845 +- 2.783 uVs I1X = -30.971 +- 0.555 uTm 17:31:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:31:32 Integrated Voltage Measurement... 17:31:41 Voltage Offset Correction: v_off_ini = 1960.753 uV, v_off_fin = 1949.406 uV 17:31:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -238.381 uVs 17:31:41 Integrated Voltage Measurement... 17:31:50 Voltage Offset Correction: v_off_ini = 1970.338 uV, v_off_fin = 1983.829 uV 17:31:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.653 uVs 17:31:50 Integrated Voltage Measurement... 17:31:59 Voltage Offset Correction: v_off_ini = 1948.178 uV, v_off_fin = 1937.289 uV 17:31:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -274.905 uVs 17:31:59 Integrated Voltage Measurement... 17:32:08 Voltage Offset Correction: v_off_ini = 1955.869 uV, v_off_fin = 1971.196 uV 17:32:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 293.580 uVs 17:32:08 Integrated Voltage Measurement... 17:32:17 Voltage Offset Correction: v_off_ini = 1936.993 uV, v_off_fin = 1963.662 uV 17:32:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.764 uVs 17:32:17 Integrated Voltage Measurement... 17:32:26 Voltage Offset Correction: v_off_ini = 1961.106 uV, v_off_fin = 1967.942 uV 17:32:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.115 uVs 17:32:31 I1Y Average and RMS of Measurements VT = -253.066 +- 22.491 uVs I1Y = -50.610 +- 4.495 uTm 17:32:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:32:38 Integrated Voltage Measurement... 17:32:47 Voltage Offset Correction: v_off_ini = 1957.848 uV, v_off_fin = 1930.661 uV 17:32:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 137.606 uVs 17:32:47 Integrated Voltage Measurement... 17:32:56 Voltage Offset Correction: v_off_ini = 1932.613 uV, v_off_fin = 1949.382 uV 17:32:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.629 uVs 17:32:56 Integrated Voltage Measurement... 17:33:05 Voltage Offset Correction: v_off_ini = 1941.050 uV, v_off_fin = 2000.202 uV 17:33:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.599 uVs 17:33:05 Integrated Voltage Measurement... 17:33:14 Voltage Offset Correction: v_off_ini = 1958.599 uV, v_off_fin = 1966.559 uV 17:33:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.765 uVs 17:33:14 Integrated Voltage Measurement... 17:33:23 Voltage Offset Correction: v_off_ini = 1938.961 uV, v_off_fin = 1953.113 uV 17:33:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.050 uVs 17:33:23 Integrated Voltage Measurement... 17:33:32 Voltage Offset Correction: v_off_ini = 1941.619 uV, v_off_fin = 1925.763 uV 17:33:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.727 uVs 17:33:35 I2X Average and RMS of Measurements VT = 169.563 +- 7.282 uVs I2X = -15.600 +- 0.670 uTm^2 17:33:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:33:43 Integrated Voltage Measurement... 17:33:52 Voltage Offset Correction: v_off_ini = 1955.004 uV, v_off_fin = 1944.940 uV 17:33:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.458 uVs 17:33:52 Integrated Voltage Measurement... 17:34:01 Voltage Offset Correction: v_off_ini = 1929.246 uV, v_off_fin = 1941.518 uV 17:34:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.296 uVs 17:34:01 Integrated Voltage Measurement... 17:34:10 Voltage Offset Correction: v_off_ini = 1914.807 uV, v_off_fin = 1930.600 uV 17:34:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.062 uVs 17:34:10 Integrated Voltage Measurement... 17:34:19 Voltage Offset Correction: v_off_ini = 1929.238 uV, v_off_fin = 1933.664 uV 17:34:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.796 uVs 17:34:19 Integrated Voltage Measurement... 17:34:28 Voltage Offset Correction: v_off_ini = 1926.839 uV, v_off_fin = 1948.244 uV 17:34:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.158 uVs 17:34:28 Integrated Voltage Measurement... 17:34:37 Voltage Offset Correction: v_off_ini = 1927.097 uV, v_off_fin = 1936.164 uV 17:34:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.651 uVs 17:34:39 I2Y Average and RMS of Measurements VT = -324.404 +- 2.428 uVs I2Y = -29.845 +- 0.223 uTm^2 17:34:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:34:53 Integrated Voltage Measurement... 17:35:02 Voltage Offset Correction: v_off_ini = 1944.953 uV, v_off_fin = 1959.902 uV 17:35:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 111.199 uVs 17:35:02 Integrated Voltage Measurement... 17:35:11 Voltage Offset Correction: v_off_ini = 1949.934 uV, v_off_fin = 1962.274 uV 17:35:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.856 uVs 17:35:11 Integrated Voltage Measurement... 17:35:20 Voltage Offset Correction: v_off_ini = 1940.789 uV, v_off_fin = 1951.693 uV 17:35:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.870 uVs 17:35:20 Integrated Voltage Measurement... 17:35:29 Voltage Offset Correction: v_off_ini = 1932.122 uV, v_off_fin = 1944.763 uV 17:35:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.022 uVs 17:35:29 Integrated Voltage Measurement... 17:35:38 Voltage Offset Correction: v_off_ini = 1952.102 uV, v_off_fin = 1941.115 uV 17:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 125.544 uVs 17:35:38 Integrated Voltage Measurement... 17:35:47 Voltage Offset Correction: v_off_ini = 1929.042 uV, v_off_fin = 1914.502 uV 17:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.329 uVs 17:35:51 I1X Average and RMS of Measurements VT = 157.470 +- 14.404 uVs I1X = -31.494 +- 2.880 uTm 17:35:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:35:58 Integrated Voltage Measurement... 17:36:07 Voltage Offset Correction: v_off_ini = 1961.015 uV, v_off_fin = 1978.114 uV 17:36:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.448 uVs 17:36:07 Integrated Voltage Measurement... 17:36:16 Voltage Offset Correction: v_off_ini = 1934.660 uV, v_off_fin = 1925.080 uV 17:36:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 241.081 uVs 17:36:16 Integrated Voltage Measurement... 17:36:25 Voltage Offset Correction: v_off_ini = 1937.412 uV, v_off_fin = 1932.315 uV 17:36:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -242.857 uVs 17:36:25 Integrated Voltage Measurement... 17:36:34 Voltage Offset Correction: v_off_ini = 1940.963 uV, v_off_fin = 1947.335 uV 17:36:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.536 uVs 17:36:34 Integrated Voltage Measurement... 17:36:43 Voltage Offset Correction: v_off_ini = 1915.058 uV, v_off_fin = 1897.577 uV 17:36:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -235.148 uVs 17:36:43 Integrated Voltage Measurement... 17:36:52 Voltage Offset Correction: v_off_ini = 1903.461 uV, v_off_fin = 1949.244 uV 17:36:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.561 uVs 17:36:56 I1Y Average and RMS of Measurements VT = -238.605 +- 4.186 uVs I1Y = -47.715 +- 0.836 uTm 17:37:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:37:04 Integrated Voltage Measurement... 17:37:13 Voltage Offset Correction: v_off_ini = 1958.282 uV, v_off_fin = 1947.417 uV 17:37:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.151 uVs 17:37:13 Integrated Voltage Measurement... 17:37:22 Voltage Offset Correction: v_off_ini = 1917.939 uV, v_off_fin = 1910.832 uV 17:37:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -144.471 uVs 17:37:22 Integrated Voltage Measurement... 17:37:31 Voltage Offset Correction: v_off_ini = 1919.492 uV, v_off_fin = 1916.534 uV 17:37:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 148.474 uVs 17:37:31 Integrated Voltage Measurement... 17:37:40 Voltage Offset Correction: v_off_ini = 1918.824 uV, v_off_fin = 1924.201 uV 17:37:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -169.777 uVs 17:37:40 Integrated Voltage Measurement... 17:37:49 Voltage Offset Correction: v_off_ini = 1921.940 uV, v_off_fin = 1930.115 uV 17:37:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.129 uVs 17:37:49 Integrated Voltage Measurement... 17:37:58 Voltage Offset Correction: v_off_ini = 1935.426 uV, v_off_fin = 1938.697 uV 17:37:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -137.915 uVs 17:38:00 I2X Average and RMS of Measurements VT = 160.986 +- 2.357 uVs I2X = -14.811 +- 0.217 uTm^2 17:38:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:38:08 Integrated Voltage Measurement... 17:38:17 Voltage Offset Correction: v_off_ini = 1910.419 uV, v_off_fin = 1925.462 uV 17:38:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.185 uVs 17:38:17 Integrated Voltage Measurement... 17:38:26 Voltage Offset Correction: v_off_ini = 1937.398 uV, v_off_fin = 1956.210 uV 17:38:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.932 uVs 17:38:26 Integrated Voltage Measurement... 17:38:35 Voltage Offset Correction: v_off_ini = 1942.247 uV, v_off_fin = 1918.082 uV 17:38:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.699 uVs 17:38:35 Integrated Voltage Measurement... 17:38:44 Voltage Offset Correction: v_off_ini = 1951.288 uV, v_off_fin = 1931.594 uV 17:38:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.111 uVs 17:38:44 Integrated Voltage Measurement... 17:38:53 Voltage Offset Correction: v_off_ini = 1959.753 uV, v_off_fin = 1926.774 uV 17:38:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.327 uVs 17:38:53 Integrated Voltage Measurement... 17:39:02 Voltage Offset Correction: v_off_ini = 1894.752 uV, v_off_fin = 1884.230 uV 17:39:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 338.720 uVs 17:39:05 I2Y Average and RMS of Measurements VT = -323.496 +- 14.173 uVs I2Y = -29.762 +- 1.304 uTm^2 17:39:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:39:19 Integrated Voltage Measurement... 17:39:28 Voltage Offset Correction: v_off_ini = 1914.518 uV, v_off_fin = 1901.895 uV 17:39:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 178.637 uVs 17:39:28 Integrated Voltage Measurement... 17:39:37 Voltage Offset Correction: v_off_ini = 1886.264 uV, v_off_fin = 1884.263 uV 17:39:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -144.164 uVs 17:39:37 Integrated Voltage Measurement... 17:39:46 Voltage Offset Correction: v_off_ini = 1881.536 uV, v_off_fin = 1894.808 uV 17:39:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.888 uVs 17:39:46 Integrated Voltage Measurement... 17:39:55 Voltage Offset Correction: v_off_ini = 1891.769 uV, v_off_fin = 1922.485 uV 17:39:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.226 uVs 17:39:55 Integrated Voltage Measurement... 17:40:04 Voltage Offset Correction: v_off_ini = 1910.174 uV, v_off_fin = 1908.161 uV 17:40:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.803 uVs 17:40:04 Integrated Voltage Measurement... 17:40:13 Voltage Offset Correction: v_off_ini = 1888.770 uV, v_off_fin = 1884.207 uV 17:40:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.119 uVs 17:40:17 I1X Average and RMS of Measurements VT = 160.140 +- 1.826 uVs I1X = -32.029 +- 0.366 uTm 17:40:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:40:24 Integrated Voltage Measurement... 17:40:33 Voltage Offset Correction: v_off_ini = 1909.333 uV, v_off_fin = 1916.409 uV 17:40:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.224 uVs 17:40:33 Integrated Voltage Measurement... 17:40:42 Voltage Offset Correction: v_off_ini = 1915.054 uV, v_off_fin = 1943.219 uV 17:40:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 245.515 uVs 17:40:42 Integrated Voltage Measurement... 17:40:51 Voltage Offset Correction: v_off_ini = 1928.108 uV, v_off_fin = 1906.758 uV 17:40:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.261 uVs 17:40:51 Integrated Voltage Measurement... 17:41:00 Voltage Offset Correction: v_off_ini = 1910.615 uV, v_off_fin = 1929.154 uV 17:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 264.953 uVs 17:41:00 Integrated Voltage Measurement... 17:41:09 Voltage Offset Correction: v_off_ini = 1926.803 uV, v_off_fin = 1935.531 uV 17:41:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -237.645 uVs 17:41:09 Integrated Voltage Measurement... 17:41:18 Voltage Offset Correction: v_off_ini = 1937.824 uV, v_off_fin = 1981.237 uV 17:41:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 256.541 uVs 17:41:22 I1Y Average and RMS of Measurements VT = -244.856 +- 2.668 uVs I1Y = -48.967 +- 0.534 uTm 17:41:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:41:30 Integrated Voltage Measurement... 17:41:39 Voltage Offset Correction: v_off_ini = 1926.108 uV, v_off_fin = 1918.503 uV 17:41:39 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = 185.827 uVs 17:41:39 Integrated Voltage Measurement... 17:41:48 Voltage Offset Correction: v_off_ini = 1917.217 uV, v_off_fin = 1923.658 uV 17:41:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -158.822 uVs 17:41:48 Integrated Voltage Measurement... 17:41:57 Voltage Offset Correction: v_off_ini = 1892.087 uV, v_off_fin = 1899.561 uV 17:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 145.216 uVs 17:41:57 Integrated Voltage Measurement... 17:42:06 Voltage Offset Correction: v_off_ini = 1958.899 uV, v_off_fin = 1959.308 uV 17:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.646 uVs 17:42:06 Integrated Voltage Measurement... 17:42:15 Voltage Offset Correction: v_off_ini = 1936.676 uV, v_off_fin = 1904.819 uV 17:42:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.086 uVs 17:42:15 Integrated Voltage Measurement... 17:42:24 Voltage Offset Correction: v_off_ini = 1938.095 uV, v_off_fin = 1944.924 uV 17:42:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.910 uVs 17:42:26 I2X Average and RMS of Measurements VT = 169.084 +- 2.423 uVs I2X = -15.555 +- 0.222 uTm^2 17:42:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:42:34 Integrated Voltage Measurement... 17:42:43 Voltage Offset Correction: v_off_ini = 1907.329 uV, v_off_fin = 1931.034 uV 17:42:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -338.590 uVs 17:42:43 Integrated Voltage Measurement... 17:42:52 Voltage Offset Correction: v_off_ini = 1935.177 uV, v_off_fin = 1942.316 uV 17:42:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.379 uVs 17:42:52 Integrated Voltage Measurement... 17:43:01 Voltage Offset Correction: v_off_ini = 1938.171 uV, v_off_fin = 1926.370 uV 17:43:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.726 uVs 17:43:01 Integrated Voltage Measurement... 17:43:10 Voltage Offset Correction: v_off_ini = 1925.764 uV, v_off_fin = 1900.289 uV 17:43:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.648 uVs 17:43:10 Integrated Voltage Measurement... 17:43:19 Voltage Offset Correction: v_off_ini = 1926.279 uV, v_off_fin = 1920.968 uV 17:43:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.611 uVs 17:43:19 Integrated Voltage Measurement... 17:43:28 Voltage Offset Correction: v_off_ini = 1939.461 uV, v_off_fin = 1931.577 uV 17:43:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.106 uVs 17:43:30 I2Y Average and RMS of Measurements VT = -331.010 +- 2.814 uVs I2Y = -30.453 +- 0.259 uTm^2 17:43:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:43:44 Integrated Voltage Measurement... 17:43:53 Voltage Offset Correction: v_off_ini = 1896.449 uV, v_off_fin = 1935.825 uV 17:43:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 160.747 uVs 17:43:53 Integrated Voltage Measurement... 17:44:02 Voltage Offset Correction: v_off_ini = 1913.523 uV, v_off_fin = 1953.688 uV 17:44:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -110.067 uVs 17:44:02 Integrated Voltage Measurement... 17:44:11 Voltage Offset Correction: v_off_ini = 1942.355 uV, v_off_fin = 1929.883 uV 17:44:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.863 uVs 17:44:11 Integrated Voltage Measurement... 17:44:20 Voltage Offset Correction: v_off_ini = 1879.960 uV, v_off_fin = 1901.667 uV 17:44:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -136.532 uVs 17:44:20 Integrated Voltage Measurement... 17:44:29 Voltage Offset Correction: v_off_ini = 1910.988 uV, v_off_fin = 1893.674 uV 17:44:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.752 uVs 17:44:29 Integrated Voltage Measurement... 17:44:38 Voltage Offset Correction: v_off_ini = 1935.738 uV, v_off_fin = 1933.868 uV 17:44:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -135.973 uVs 17:44:43 I1X Average and RMS of Measurements VT = 142.156 +- 4.820 uVs I1X = -28.432 +- 0.963 uTm 17:44:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:44:49 Integrated Voltage Measurement... 17:44:58 Voltage Offset Correction: v_off_ini = 1934.104 uV, v_off_fin = 1886.506 uV 17:44:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.248 uVs 17:44:58 Integrated Voltage Measurement... 17:45:07 Voltage Offset Correction: v_off_ini = 1923.878 uV, v_off_fin = 1892.701 uV 17:45:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 258.435 uVs 17:45:07 Integrated Voltage Measurement... 17:45:16 Voltage Offset Correction: v_off_ini = 1871.780 uV, v_off_fin = 1879.183 uV 17:45:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -254.061 uVs 17:45:16 Integrated Voltage Measurement... 17:45:25 Voltage Offset Correction: v_off_ini = 1881.021 uV, v_off_fin = 1909.258 uV 17:45:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 240.705 uVs 17:45:25 Integrated Voltage Measurement... 17:45:34 Voltage Offset Correction: v_off_ini = 1911.482 uV, v_off_fin = 1908.680 uV 17:45:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -247.760 uVs 17:45:34 Integrated Voltage Measurement... 17:45:43 Voltage Offset Correction: v_off_ini = 1907.648 uV, v_off_fin = 1903.054 uV 17:45:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.436 uVs 17:45:48 I1Y Average and RMS of Measurements VT = -246.274 +- 6.480 uVs I1Y = -49.250 +- 1.296 uTm 17:45:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:45:55 Integrated Voltage Measurement... 17:46:04 Voltage Offset Correction: v_off_ini = 1878.771 uV, v_off_fin = 1895.260 uV 17:46:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 161.706 uVs 17:46:04 Integrated Voltage Measurement... 17:46:13 Voltage Offset Correction: v_off_ini = 1886.906 uV, v_off_fin = 1908.552 uV 17:46:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -125.415 uVs 17:46:13 Integrated Voltage Measurement... 17:46:22 Voltage Offset Correction: v_off_ini = 1914.989 uV, v_off_fin = 1894.724 uV 17:46:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 121.605 uVs 17:46:22 Integrated Voltage Measurement... 17:46:31 Voltage Offset Correction: v_off_ini = 1904.715 uV, v_off_fin = 1897.100 uV 17:46:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -132.520 uVs 17:46:31 Integrated Voltage Measurement... 17:46:40 Voltage Offset Correction: v_off_ini = 1894.005 uV, v_off_fin = 1881.470 uV 17:46:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 160.015 uVs 17:46:40 Integrated Voltage Measurement... 17:46:49 Voltage Offset Correction: v_off_ini = 1868.600 uV, v_off_fin = 1900.478 uV 17:46:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.593 uVs 17:46:52 I2X Average and RMS of Measurements VT = 146.642 +- 17.382 uVs I2X = -13.491 +- 1.599 uTm^2 17:46:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:46:59 Integrated Voltage Measurement... 17:47:08 Voltage Offset Correction: v_off_ini = 1891.239 uV, v_off_fin = 1868.477 uV 17:47:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.424 uVs 17:47:08 Integrated Voltage Measurement... 17:47:17 Voltage Offset Correction: v_off_ini = 1932.450 uV, v_off_fin = 1896.232 uV 17:47:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.757 uVs 17:47:18 Integrated Voltage Measurement... 17:47:26 Voltage Offset Correction: v_off_ini = 1898.093 uV, v_off_fin = 1903.347 uV 17:47:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.411 uVs 17:47:27 Integrated Voltage Measurement... 17:47:36 Voltage Offset Correction: v_off_ini = 1920.025 uV, v_off_fin = 1902.537 uV 17:47:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.577 uVs 17:47:36 Integrated Voltage Measurement... 17:47:45 Voltage Offset Correction: v_off_ini = 1877.194 uV, v_off_fin = 1916.499 uV 17:47:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.024 uVs 17:47:45 Integrated Voltage Measurement... 17:47:54 Voltage Offset Correction: v_off_ini = 1892.550 uV, v_off_fin = 1942.605 uV 17:47:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.014 uVs 17:47:56 I2Y Average and RMS of Measurements VT = -325.034 +- 11.697 uVs I2Y = -29.903 +- 1.076 uTm^2 17:48:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:48:10 Integrated Voltage Measurement... 17:48:19 Voltage Offset Correction: v_off_ini = 1866.707 uV, v_off_fin = 1901.684 uV 17:48:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.205 uVs 17:48:19 Integrated Voltage Measurement... 17:48:28 Voltage Offset Correction: v_off_ini = 1938.093 uV, v_off_fin = 1938.229 uV 17:48:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -156.460 uVs 17:48:28 Integrated Voltage Measurement... 17:48:37 Voltage Offset Correction: v_off_ini = 1915.193 uV, v_off_fin = 1913.779 uV 17:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 125.314 uVs 17:48:37 Integrated Voltage Measurement... 17:48:46 Voltage Offset Correction: v_off_ini = 1924.570 uV, v_off_fin = 1921.153 uV 17:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -147.192 uVs 17:48:46 Integrated Voltage Measurement... 17:48:55 Voltage Offset Correction: v_off_ini = 1970.719 uV, v_off_fin = 1914.276 uV 17:48:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 124.585 uVs 17:48:55 Integrated Voltage Measurement... 17:49:04 Voltage Offset Correction: v_off_ini = 1919.333 uV, v_off_fin = 1935.837 uV 17:49:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.212 uVs 17:49:08 I1X Average and RMS of Measurements VT = 145.328 +- 8.575 uVs I1X = -29.066 +- 1.715 uTm 17:49:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:49:15 Integrated Voltage Measurement... 17:49:24 Voltage Offset Correction: v_off_ini = 1930.968 uV, v_off_fin = 1926.007 uV 17:49:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -253.774 uVs 17:49:24 Integrated Voltage Measurement... 17:49:33 Voltage Offset Correction: v_off_ini = 1896.489 uV, v_off_fin = 1931.524 uV 17:49:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 242.722 uVs 17:49:33 Integrated Voltage Measurement... 17:49:42 Voltage Offset Correction: v_off_ini = 1906.929 uV, v_off_fin = 1920.913 uV 17:49:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -289.268 uVs 17:49:42 Integrated Voltage Measurement... 17:49:51 Voltage Offset Correction: v_off_ini = 1908.132 uV, v_off_fin = 1909.040 uV 17:49:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 241.497 uVs 17:49:51 Integrated Voltage Measurement... 17:50:00 Voltage Offset Correction: v_off_ini = 1934.372 uV, v_off_fin = 1912.374 uV 17:50:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.012 uVs 17:50:00 Integrated Voltage Measurement... 17:50:09 Voltage Offset Correction: v_off_ini = 1905.326 uV, v_off_fin = 1892.925 uV 17:50:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.841 uVs 17:50:13 I1Y Average and RMS of Measurements VT = -242.352 +- 21.617 uVs I1Y = -48.464 +- 4.319 uTm 17:50:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:50:21 Integrated Voltage Measurement... 17:50:30 Voltage Offset Correction: v_off_ini = 1930.664 uV, v_off_fin = 1919.311 uV 17:50:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.579 uVs 17:50:30 Integrated Voltage Measurement... 17:50:39 Voltage Offset Correction: v_off_ini = 1928.535 uV, v_off_fin = 1926.916 uV 17:50:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.179 uVs 17:50:39 Integrated Voltage Measurement... 17:50:48 Voltage Offset Correction: v_off_ini = 1914.770 uV, v_off_fin = 1905.432 uV 17:50:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.935 uVs 17:50:48 Integrated Voltage Measurement... 17:50:57 Voltage Offset Correction: v_off_ini = 1914.516 uV, v_off_fin = 1913.919 uV 17:50:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -159.197 uVs 17:50:57 Integrated Voltage Measurement... 17:51:06 Voltage Offset Correction: v_off_ini = 1878.305 uV, v_off_fin = 1889.209 uV 17:51:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 124.043 uVs 17:51:06 Integrated Voltage Measurement... 17:51:15 Voltage Offset Correction: v_off_ini = 1870.752 uV, v_off_fin = 1899.589 uV 17:51:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -147.664 uVs 17:51:17 I2X Average and RMS of Measurements VT = 163.266 +- 19.398 uVs I2X = -15.020 +- 1.785 uTm^2 17:51:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:51:25 Integrated Voltage Measurement... 17:51:34 Voltage Offset Correction: v_off_ini = 1904.294 uV, v_off_fin = 1935.825 uV 17:51:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.697 uVs 17:51:34 Integrated Voltage Measurement... 17:51:43 Voltage Offset Correction: v_off_ini = 1915.586 uV, v_off_fin = 1909.604 uV 17:51:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.724 uVs 17:51:43 Integrated Voltage Measurement... 17:51:52 Voltage Offset Correction: v_off_ini = 1912.942 uV, v_off_fin = 1887.082 uV 17:51:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0001 mm dXY = 1.0000 mm VT = -298.403 uVs 17:51:52 Integrated Voltage Measurement... 17:52:01 Voltage Offset Correction: v_off_ini = 1900.171 uV, v_off_fin = 1917.115 uV 17:52:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 299.186 uVs 17:52:01 Integrated Voltage Measurement... 17:52:10 Voltage Offset Correction: v_off_ini = 1908.585 uV, v_off_fin = 1920.213 uV 17:52:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.063 uVs 17:52:10 Integrated Voltage Measurement... 17:52:19 Voltage Offset Correction: v_off_ini = 1922.782 uV, v_off_fin = 1908.901 uV 17:52:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 328.598 uVs 17:52:22 I2Y Average and RMS of Measurements VT = -306.945 +- 7.212 uVs I2Y = -28.239 +- 0.664 uTm^2 17:52:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:52:37 Integrated Voltage Measurement... 17:52:46 Voltage Offset Correction: v_off_ini = 1933.792 uV, v_off_fin = 1921.713 uV 17:52:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 143.116 uVs 17:52:46 Integrated Voltage Measurement... 17:52:55 Voltage Offset Correction: v_off_ini = 1916.125 uV, v_off_fin = 1878.432 uV 17:52:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.716 uVs 17:52:55 Integrated Voltage Measurement... 17:53:04 Voltage Offset Correction: v_off_ini = 1884.391 uV, v_off_fin = 1922.272 uV 17:53:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 144.195 uVs 17:53:04 Integrated Voltage Measurement... 17:53:13 Voltage Offset Correction: v_off_ini = 1887.694 uV, v_off_fin = 1865.351 uV 17:53:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -124.401 uVs 17:53:13 Integrated Voltage Measurement... 17:53:22 Voltage Offset Correction: v_off_ini = 1886.083 uV, v_off_fin = 1897.999 uV 17:53:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.443 uVs 17:53:22 Integrated Voltage Measurement... 17:53:31 Voltage Offset Correction: v_off_ini = 1885.125 uV, v_off_fin = 1908.239 uV 17:53:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -94.652 uVs 17:53:35 I1X Average and RMS of Measurements VT = 136.420 +- 7.447 uVs I1X = -27.285 +- 1.490 uTm 17:53:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:53:42 Integrated Voltage Measurement... 17:53:51 Voltage Offset Correction: v_off_ini = 1871.624 uV, v_off_fin = 1887.001 uV 17:53:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -247.624 uVs 17:53:51 Integrated Voltage Measurement... 17:54:00 Voltage Offset Correction: v_off_ini = 1889.869 uV, v_off_fin = 1906.865 uV 17:54:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.817 uVs 17:54:00 Integrated Voltage Measurement... 17:54:09 Voltage Offset Correction: v_off_ini = 1911.966 uV, v_off_fin = 1858.876 uV 17:54:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.863 uVs 17:54:09 Integrated Voltage Measurement... 17:54:18 Voltage Offset Correction: v_off_ini = 1940.283 uV, v_off_fin = 1915.019 uV 17:54:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 237.854 uVs 17:54:18 Integrated Voltage Measurement... 17:54:27 Voltage Offset Correction: v_off_ini = 1898.471 uV, v_off_fin = 1879.768 uV 17:54:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -250.562 uVs 17:54:27 Integrated Voltage Measurement... 17:54:36 Voltage Offset Correction: v_off_ini = 1891.107 uV, v_off_fin = 1904.227 uV 17:54:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.265 uVs 17:54:40 I1Y Average and RMS of Measurements VT = -232.998 +- 6.484 uVs I1Y = -46.594 +- 1.296 uTm 17:54:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:54:48 Integrated Voltage Measurement... 17:54:57 Voltage Offset Correction: v_off_ini = 1860.105 uV, v_off_fin = 1890.735 uV 17:54:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 136.065 uVs 17:54:57 Integrated Voltage Measurement... 17:55:06 Voltage Offset Correction: v_off_ini = 1912.352 uV, v_off_fin = 1888.219 uV 17:55:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -132.765 uVs 17:55:06 Integrated Voltage Measurement... 17:55:15 Voltage Offset Correction: v_off_ini = 1941.305 uV, v_off_fin = 1941.287 uV 17:55:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.311 uVs 17:55:15 Integrated Voltage Measurement... 17:55:24 Voltage Offset Correction: v_off_ini = 1926.328 uV, v_off_fin = 1939.223 uV 17:55:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -134.480 uVs 17:55:24 Integrated Voltage Measurement... 17:55:33 Voltage Offset Correction: v_off_ini = 1941.291 uV, v_off_fin = 1933.029 uV 17:55:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 135.536 uVs 17:55:33 Integrated Voltage Measurement... 17:55:42 Voltage Offset Correction: v_off_ini = 1931.243 uV, v_off_fin = 1908.728 uV 17:55:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.195 uVs 17:55:44 I2X Average and RMS of Measurements VT = 146.226 +- 8.415 uVs I2X = -13.453 +- 0.774 uTm^2 17:55:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:55:52 Integrated Voltage Measurement... 17:56:01 Voltage Offset Correction: v_off_ini = 1919.339 uV, v_off_fin = 1920.390 uV 17:56:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.684 uVs 17:56:01 Integrated Voltage Measurement... 17:56:10 Voltage Offset Correction: v_off_ini = 1920.919 uV, v_off_fin = 1920.682 uV 17:56:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.472 uVs 17:56:10 Integrated Voltage Measurement... 17:56:19 Voltage Offset Correction: v_off_ini = 1905.963 uV, v_off_fin = 1913.924 uV 17:56:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.286 uVs 17:56:19 Integrated Voltage Measurement... 17:56:28 Voltage Offset Correction: v_off_ini = 1940.363 uV, v_off_fin = 1934.885 uV 17:56:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.743 uVs 17:56:28 Integrated Voltage Measurement... 17:56:37 Voltage Offset Correction: v_off_ini = 1932.161 uV, v_off_fin = 1921.232 uV 17:56:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.323 uVs 17:56:37 Integrated Voltage Measurement... 17:56:46 Voltage Offset Correction: v_off_ini = 1935.006 uV, v_off_fin = 1887.792 uV 17:56:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.985 uVs 17:56:49 I2Y Average and RMS of Measurements VT = -302.415 +- 13.448 uVs I2Y = -27.822 +- 1.237 uTm^2 17:56:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:57:04 Integrated Voltage Measurement... 17:57:13 Voltage Offset Correction: v_off_ini = 1966.691 uV, v_off_fin = 1966.603 uV 17:57:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 119.621 uVs 17:57:13 Integrated Voltage Measurement... 17:57:22 Voltage Offset Correction: v_off_ini = 1970.360 uV, v_off_fin = 1945.716 uV 17:57:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -95.696 uVs 17:57:22 Integrated Voltage Measurement... 17:57:31 Voltage Offset Correction: v_off_ini = 1971.711 uV, v_off_fin = 1961.689 uV 17:57:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.590 uVs 17:57:31 Integrated Voltage Measurement... 17:57:40 Voltage Offset Correction: v_off_ini = 1967.771 uV, v_off_fin = 1946.595 uV 17:57:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -119.213 uVs 17:57:40 Integrated Voltage Measurement... 17:57:49 Voltage Offset Correction: v_off_ini = 1932.431 uV, v_off_fin = 1946.981 uV 17:57:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 154.635 uVs 17:57:49 Integrated Voltage Measurement... 17:57:58 Voltage Offset Correction: v_off_ini = 1930.787 uV, v_off_fin = 1953.250 uV 17:57:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -116.250 uVs 17:58:02 I1X Average and RMS of Measurements VT = 125.834 +- 12.859 uVs I1X = -25.167 +- 2.571 uTm 17:58:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:58:09 Integrated Voltage Measurement... 17:58:18 Voltage Offset Correction: v_off_ini = 1929.392 uV, v_off_fin = 1932.064 uV 17:58:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -227.773 uVs 17:58:18 Integrated Voltage Measurement... 17:58:27 Voltage Offset Correction: v_off_ini = 1924.389 uV, v_off_fin = 1920.573 uV 17:58:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 259.241 uVs 17:58:27 Integrated Voltage Measurement... 17:58:36 Voltage Offset Correction: v_off_ini = 1926.351 uV, v_off_fin = 1919.313 uV 17:58:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.440 uVs 17:58:36 Integrated Voltage Measurement... 17:58:45 Voltage Offset Correction: v_off_ini = 1938.745 uV, v_off_fin = 1945.853 uV 17:58:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.206 uVs 17:58:45 Integrated Voltage Measurement... 17:58:54 Voltage Offset Correction: v_off_ini = 1945.779 uV, v_off_fin = 1902.551 uV 17:58:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.087 uVs 17:58:54 Integrated Voltage Measurement... 17:59:03 Voltage Offset Correction: v_off_ini = 1887.716 uV, v_off_fin = 1959.813 uV 17:59:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.137 uVs 17:59:07 I1Y Average and RMS of Measurements VT = -229.314 +- 14.545 uVs I1Y = -45.859 +- 2.909 uTm 17:59:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:59:15 Integrated Voltage Measurement... 17:59:24 Voltage Offset Correction: v_off_ini = 1915.392 uV, v_off_fin = 1922.689 uV 17:59:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 122.835 uVs 17:59:24 Integrated Voltage Measurement... 17:59:33 Voltage Offset Correction: v_off_ini = 1937.876 uV, v_off_fin = 1932.617 uV 17:59:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -127.016 uVs 17:59:33 Integrated Voltage Measurement... 17:59:42 Voltage Offset Correction: v_off_ini = 1940.754 uV, v_off_fin = 1898.952 uV 17:59:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.672 uVs 17:59:42 Integrated Voltage Measurement... 17:59:51 Voltage Offset Correction: v_off_ini = 1924.103 uV, v_off_fin = 1935.450 uV 17:59:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -124.726 uVs 17:59:51 Integrated Voltage Measurement... 18:00:00 Voltage Offset Correction: v_off_ini = 1953.031 uV, v_off_fin = 1917.876 uV 18:00:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 133.555 uVs 18:00:00 Integrated Voltage Measurement... 18:00:09 Voltage Offset Correction: v_off_ini = 1919.713 uV, v_off_fin = 1939.947 uV 18:00:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -120.288 uVs 18:00:11 I2X Average and RMS of Measurements VT = 130.682 +- 6.779 uVs I2X = -12.023 +- 0.624 uTm^2 18:00:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:00:19 Integrated Voltage Measurement... 18:00:28 Voltage Offset Correction: v_off_ini = 1921.039 uV, v_off_fin = 1909.681 uV 18:00:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.432 uVs 18:00:28 Integrated Voltage Measurement... 18:00:37 Voltage Offset Correction: v_off_ini = 1915.958 uV, v_off_fin = 1933.990 uV 18:00:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.031 uVs 18:00:37 Integrated Voltage Measurement... 18:00:46 Voltage Offset Correction: v_off_ini = 1911.940 uV, v_off_fin = 1902.949 uV 18:00:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.439 uVs 18:00:46 Integrated Voltage Measurement... 18:00:55 Voltage Offset Correction: v_off_ini = 1956.852 uV, v_off_fin = 1919.517 uV 18:00:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.512 uVs 18:00:55 Integrated Voltage Measurement... 18:01:04 Voltage Offset Correction: v_off_ini = 1886.611 uV, v_off_fin = 1919.320 uV 18:01:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.938 uVs 18:01:04 Integrated Voltage Measurement... 18:01:13 Voltage Offset Correction: v_off_ini = 1902.263 uV, v_off_fin = 1917.959 uV 18:01:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.081 uVs 18:01:16 I2Y Average and RMS of Measurements VT = -298.905 +- 11.458 uVs I2Y = -27.499 +- 1.054 uTm^2 18:01:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:01:33 Integrated Voltage Measurement... 18:01:42 Voltage Offset Correction: v_off_ini = 1958.473 uV, v_off_fin = 1920.925 uV 18:01:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 101.485 uVs 18:01:42 Integrated Voltage Measurement... 18:01:51 Voltage Offset Correction: v_off_ini = 1911.909 uV, v_off_fin = 1915.060 uV 18:01:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -87.052 uVs 18:01:51 Integrated Voltage Measurement... 18:02:00 Voltage Offset Correction: v_off_ini = 1913.424 uV, v_off_fin = 1902.814 uV 18:02:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 52.187 uVs 18:02:00 Integrated Voltage Measurement... 18:02:09 Voltage Offset Correction: v_off_ini = 1896.076 uV, v_off_fin = 1896.042 uV 18:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -105.910 uVs 18:02:09 Integrated Voltage Measurement... 18:02:18 Voltage Offset Correction: v_off_ini = 1902.516 uV, v_off_fin = 1900.411 uV 18:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 74.653 uVs 18:02:18 Integrated Voltage Measurement... 18:02:27 Voltage Offset Correction: v_off_ini = 1896.458 uV, v_off_fin = 1937.504 uV 18:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -119.869 uVs 18:02:31 I1X Average and RMS of Measurements VT = 90.193 +- 7.974 uVs I1X = -18.039 +- 1.595 uTm 18:02:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:02:38 Integrated Voltage Measurement... 18:02:47 Voltage Offset Correction: v_off_ini = 1959.748 uV, v_off_fin = 1943.814 uV 18:02:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.734 uVs 18:02:47 Integrated Voltage Measurement... 18:02:56 Voltage Offset Correction: v_off_ini = 1929.064 uV, v_off_fin = 1926.257 uV 18:02:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.381 uVs 18:02:56 Integrated Voltage Measurement... 18:03:05 Voltage Offset Correction: v_off_ini = 1927.857 uV, v_off_fin = 1925.943 uV 18:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -266.589 uVs 18:03:05 Integrated Voltage Measurement... 18:03:14 Voltage Offset Correction: v_off_ini = 1933.700 uV, v_off_fin = 1951.126 uV 18:03:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.821 uVs 18:03:14 Integrated Voltage Measurement... 18:03:23 Voltage Offset Correction: v_off_ini = 1925.407 uV, v_off_fin = 1868.960 uV 18:03:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -236.234 uVs 18:03:23 Integrated Voltage Measurement... 18:03:32 Voltage Offset Correction: v_off_ini = 1928.682 uV, v_off_fin = 1929.161 uV 18:03:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.104 uVs 18:03:36 I1Y Average and RMS of Measurements VT = -234.477 +- 12.820 uVs I1Y = -46.892 +- 2.563 uTm 18:03:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:03:44 Integrated Voltage Measurement... 18:03:53 Voltage Offset Correction: v_off_ini = 1898.100 uV, v_off_fin = 1909.559 uV 18:03:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.225 uVs 18:03:53 Integrated Voltage Measurement... 18:04:02 Voltage Offset Correction: v_off_ini = 1954.946 uV, v_off_fin = 1977.254 uV 18:04:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -102.529 uVs 18:04:02 Integrated Voltage Measurement... 18:04:11 Voltage Offset Correction: v_off_ini = 1955.275 uV, v_off_fin = 1934.440 uV 18:04:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 86.051 uVs 18:04:11 Integrated Voltage Measurement... 18:04:20 Voltage Offset Correction: v_off_ini = 1928.967 uV, v_off_fin = 1953.348 uV 18:04:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -141.516 uVs 18:04:20 Integrated Voltage Measurement... 18:04:29 Voltage Offset Correction: v_off_ini = 1966.744 uV, v_off_fin = 1965.857 uV 18:04:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 105.764 uVs 18:04:29 Integrated Voltage Measurement... 18:04:38 Voltage Offset Correction: v_off_ini = 1951.676 uV, v_off_fin = 1959.060 uV 18:04:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -60.305 uVs 18:04:40 I2X Average and RMS of Measurements VT = 108.565 +- 19.075 uVs I2X = -9.988 +- 1.755 uTm^2 18:04:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:04:48 Integrated Voltage Measurement... 18:04:57 Voltage Offset Correction: v_off_ini = 1928.365 uV, v_off_fin = 1957.915 uV 18:04:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.876 uVs 18:04:57 Integrated Voltage Measurement... 18:05:06 Voltage Offset Correction: v_off_ini = 1937.783 uV, v_off_fin = 1938.515 uV 18:05:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.314 uVs 18:05:06 Integrated Voltage Measurement... 18:05:15 Voltage Offset Correction: v_off_ini = 1919.787 uV, v_off_fin = 1921.225 uV 18:05:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.742 uVs 18:05:15 Integrated Voltage Measurement... 18:05:24 Voltage Offset Correction: v_off_ini = 1936.427 uV, v_off_fin = 1928.309 uV 18:05:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.828 uVs 18:05:24 Integrated Voltage Measurement... 18:05:33 Voltage Offset Correction: v_off_ini = 1943.184 uV, v_off_fin = 1935.484 uV 18:05:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.534 uVs 18:05:33 Integrated Voltage Measurement... 18:05:42 Voltage Offset Correction: v_off_ini = 1923.267 uV, v_off_fin = 1921.112 uV 18:05:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.642 uVs 18:05:45 I2Y Average and RMS of Measurements VT = -296.656 +- 11.589 uVs I2Y = -27.292 +- 1.066 uTm^2 18:05:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:06:02 Integrated Voltage Measurement... 18:06:11 Voltage Offset Correction: v_off_ini = 1914.254 uV, v_off_fin = 1931.911 uV 18:06:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 79.187 uVs 18:06:11 Integrated Voltage Measurement... 18:06:20 Voltage Offset Correction: v_off_ini = 1918.187 uV, v_off_fin = 1927.830 uV 18:06:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -73.719 uVs 18:06:20 Integrated Voltage Measurement... 18:06:29 Voltage Offset Correction: v_off_ini = 1918.752 uV, v_off_fin = 1919.411 uV 18:06:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 90.640 uVs 18:06:29 Integrated Voltage Measurement... 18:06:38 Voltage Offset Correction: v_off_ini = 1912.719 uV, v_off_fin = 1926.848 uV 18:06:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -61.540 uVs 18:06:38 Integrated Voltage Measurement... 18:06:47 Voltage Offset Correction: v_off_ini = 1922.157 uV, v_off_fin = 1925.920 uV 18:06:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 110.064 uVs 18:06:47 Integrated Voltage Measurement... 18:06:56 Voltage Offset Correction: v_off_ini = 1909.071 uV, v_off_fin = 1893.644 uV 18:06:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -58.763 uVs 18:07:00 I1X Average and RMS of Measurements VT = 78.986 +- 3.841 uVs I1X = -15.797 +- 0.768 uTm 18:07:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:07:07 Integrated Voltage Measurement... 18:07:16 Voltage Offset Correction: v_off_ini = 1924.118 uV, v_off_fin = 1896.108 uV 18:07:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.901 uVs 18:07:16 Integrated Voltage Measurement... 18:07:25 Voltage Offset Correction: v_off_ini = 1912.751 uV, v_off_fin = 1911.437 uV 18:07:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.814 uVs 18:07:25 Integrated Voltage Measurement... 18:07:34 Voltage Offset Correction: v_off_ini = 1906.887 uV, v_off_fin = 1916.897 uV 18:07:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -234.883 uVs 18:07:34 Integrated Voltage Measurement... 18:07:43 Voltage Offset Correction: v_off_ini = 1920.907 uV, v_off_fin = 1933.919 uV 18:07:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 239.013 uVs 18:07:43 Integrated Voltage Measurement... 18:07:52 Voltage Offset Correction: v_off_ini = 1904.204 uV, v_off_fin = 1911.974 uV 18:07:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -220.377 uVs 18:07:52 Integrated Voltage Measurement... 18:08:01 Voltage Offset Correction: v_off_ini = 1894.760 uV, v_off_fin = 1911.293 uV 18:08:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.993 uVs 18:08:05 I1Y Average and RMS of Measurements VT = -231.663 +- 11.127 uVs I1Y = -46.327 +- 2.227 uTm 18:08:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:08:13 Integrated Voltage Measurement... 18:08:22 Voltage Offset Correction: v_off_ini = 1899.085 uV, v_off_fin = 1922.727 uV 18:08:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 112.302 uVs 18:08:22 Integrated Voltage Measurement... 18:08:31 Voltage Offset Correction: v_off_ini = 1936.548 uV, v_off_fin = 1903.135 uV 18:08:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -77.729 uVs 18:08:31 Integrated Voltage Measurement... 18:08:40 Voltage Offset Correction: v_off_ini = 1915.134 uV, v_off_fin = 1912.393 uV 18:08:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 62.709 uVs 18:08:40 Integrated Voltage Measurement... 18:08:49 Voltage Offset Correction: v_off_ini = 1891.033 uV, v_off_fin = 1914.315 uV 18:08:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -90.291 uVs 18:08:49 Integrated Voltage Measurement... 18:08:58 Voltage Offset Correction: v_off_ini = 1906.610 uV, v_off_fin = 1902.244 uV 18:08:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 61.297 uVs 18:08:58 Integrated Voltage Measurement... 18:09:07 Voltage Offset Correction: v_off_ini = 1874.061 uV, v_off_fin = 1894.372 uV 18:09:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -108.529 uVs 18:09:10 I2X Average and RMS of Measurements VT = 85.476 +- 7.569 uVs I2X = -7.864 +- 0.696 uTm^2 18:09:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:09:17 Integrated Voltage Measurement... 18:09:26 Voltage Offset Correction: v_off_ini = 1882.752 uV, v_off_fin = 1883.333 uV 18:09:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.310 uVs 18:09:26 Integrated Voltage Measurement... 18:09:35 Voltage Offset Correction: v_off_ini = 1896.467 uV, v_off_fin = 1910.042 uV 18:09:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.437 uVs 18:09:35 Integrated Voltage Measurement... 18:09:44 Voltage Offset Correction: v_off_ini = 1899.571 uV, v_off_fin = 1850.779 uV 18:09:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.788 uVs 18:09:44 Integrated Voltage Measurement... 18:09:53 Voltage Offset Correction: v_off_ini = 1868.265 uV, v_off_fin = 1904.274 uV 18:09:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.066 uVs 18:09:53 Integrated Voltage Measurement... 18:10:02 Voltage Offset Correction: v_off_ini = 1891.121 uV, v_off_fin = 1893.089 uV 18:10:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.103 uVs 18:10:02 Integrated Voltage Measurement... 18:10:11 Voltage Offset Correction: v_off_ini = 1889.419 uV, v_off_fin = 1879.284 uV 18:10:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.345 uVs 18:10:14 I2Y Average and RMS of Measurements VT = -286.675 +- 6.799 uVs I2Y = -26.374 +- 0.626 uTm^2 18:10:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:10:31 Integrated Voltage Measurement... 18:10:40 Voltage Offset Correction: v_off_ini = 1876.957 uV, v_off_fin = 1863.699 uV 18:10:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 40.943 uVs 18:10:40 Integrated Voltage Measurement... 18:10:49 Voltage Offset Correction: v_off_ini = 1850.817 uV, v_off_fin = 1868.814 uV 18:10:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -15.167 uVs 18:10:49 Integrated Voltage Measurement... 18:10:58 Voltage Offset Correction: v_off_ini = 1882.329 uV, v_off_fin = 1885.614 uV 18:10:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 63.985 uVs 18:10:58 Integrated Voltage Measurement... 18:11:07 Voltage Offset Correction: v_off_ini = 1857.229 uV, v_off_fin = 1864.985 uV 18:11:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -34.302 uVs 18:11:07 Integrated Voltage Measurement... 18:11:16 Voltage Offset Correction: v_off_ini = 1885.381 uV, v_off_fin = 1895.735 uV 18:11:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 55.534 uVs 18:11:16 Integrated Voltage Measurement... 18:11:25 Voltage Offset Correction: v_off_ini = 1883.845 uV, v_off_fin = 1872.532 uV 18:11:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -48.694 uVs 18:11:29 I1X Average and RMS of Measurements VT = 43.104 +- 10.710 uVs I1X = -8.621 +- 2.142 uTm 18:11:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:11:36 Integrated Voltage Measurement... 18:11:45 Voltage Offset Correction: v_off_ini = 1900.587 uV, v_off_fin = 1854.536 uV 18:11:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.838 uVs 18:11:45 Integrated Voltage Measurement... 18:11:54 Voltage Offset Correction: v_off_ini = 1889.765 uV, v_off_fin = 1903.858 uV 18:11:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.320 uVs 18:11:54 Integrated Voltage Measurement... 18:12:03 Voltage Offset Correction: v_off_ini = 1890.953 uV, v_off_fin = 1874.928 uV 18:12:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.504 uVs 18:12:03 Integrated Voltage Measurement... 18:12:12 Voltage Offset Correction: v_off_ini = 1895.512 uV, v_off_fin = 1908.138 uV 18:12:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.944 uVs 18:12:12 Integrated Voltage Measurement... 18:12:21 Voltage Offset Correction: v_off_ini = 1886.698 uV, v_off_fin = 1869.482 uV 18:12:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -262.085 uVs 18:12:21 Integrated Voltage Measurement... 18:12:30 Voltage Offset Correction: v_off_ini = 1880.101 uV, v_off_fin = 1916.614 uV 18:12:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.771 uVs 18:12:34 I1Y Average and RMS of Measurements VT = -232.244 +- 13.110 uVs I1Y = -46.446 +- 2.621 uTm 18:12:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:12:42 Integrated Voltage Measurement... 18:12:51 Voltage Offset Correction: v_off_ini = 1863.983 uV, v_off_fin = 1872.083 uV 18:12:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 68.947 uVs 18:12:51 Integrated Voltage Measurement... 18:13:00 Voltage Offset Correction: v_off_ini = 1877.792 uV, v_off_fin = 1896.629 uV 18:13:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -29.952 uVs 18:13:00 Integrated Voltage Measurement... 18:13:09 Voltage Offset Correction: v_off_ini = 1871.115 uV, v_off_fin = 1875.935 uV 18:13:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 45.965 uVs 18:13:09 Integrated Voltage Measurement... 18:13:18 Voltage Offset Correction: v_off_ini = 1900.709 uV, v_off_fin = 1907.817 uV 18:13:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -48.010 uVs 18:13:18 Integrated Voltage Measurement... 18:13:27 Voltage Offset Correction: v_off_ini = 1870.517 uV, v_off_fin = 1855.815 uV 18:13:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 33.654 uVs 18:13:27 Integrated Voltage Measurement... 18:13:36 Voltage Offset Correction: v_off_ini = 1872.512 uV, v_off_fin = 1871.316 uV 18:13:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -52.068 uVs 18:13:38 I2X Average and RMS of Measurements VT = 46.433 +- 2.718 uVs I2X = -4.272 +- 0.250 uTm^2 18:13:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:13:46 Integrated Voltage Measurement... 18:13:55 Voltage Offset Correction: v_off_ini = 1858.960 uV, v_off_fin = 1871.037 uV 18:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.152 uVs 18:13:55 Integrated Voltage Measurement... 18:14:04 Voltage Offset Correction: v_off_ini = 1840.538 uV, v_off_fin = 1820.457 uV 18:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.888 uVs 18:14:04 Integrated Voltage Measurement... 18:14:13 Voltage Offset Correction: v_off_ini = 1831.767 uV, v_off_fin = 1810.837 uV 18:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.300 uVs 18:14:13 Integrated Voltage Measurement... 18:14:22 Voltage Offset Correction: v_off_ini = 1840.500 uV, v_off_fin = 1818.907 uV 18:14:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.788 uVs 18:14:22 Integrated Voltage Measurement... 18:14:31 Voltage Offset Correction: v_off_ini = 1837.885 uV, v_off_fin = 1848.444 uV 18:14:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.912 uVs 18:14:31 Integrated Voltage Measurement... 18:14:40 Voltage Offset Correction: v_off_ini = 1854.222 uV, v_off_fin = 1851.223 uV 18:14:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.674 uVs 18:14:43 I2Y Average and RMS of Measurements VT = -276.619 +- 16.293 uVs I2Y = -25.449 +- 1.499 uTm^2 18:14:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:15:00 Integrated Voltage Measurement... 18:15:09 Voltage Offset Correction: v_off_ini = 1877.872 uV, v_off_fin = 1866.352 uV 18:15:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 30.658 uVs 18:15:09 Integrated Voltage Measurement... 18:15:18 Voltage Offset Correction: v_off_ini = 1845.372 uV, v_off_fin = 1823.576 uV 18:15:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -18.636 uVs 18:15:18 Integrated Voltage Measurement... 18:15:27 Voltage Offset Correction: v_off_ini = 1847.879 uV, v_off_fin = 1838.480 uV 18:15:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 53.517 uVs 18:15:27 Integrated Voltage Measurement... 18:15:36 Voltage Offset Correction: v_off_ini = 1832.381 uV, v_off_fin = 1835.414 uV 18:15:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -34.616 uVs 18:15:36 Integrated Voltage Measurement... 18:15:45 Voltage Offset Correction: v_off_ini = 1854.721 uV, v_off_fin = 1828.958 uV 18:15:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 11.106 uVs 18:15:45 Integrated Voltage Measurement... 18:15:54 Voltage Offset Correction: v_off_ini = 1820.306 uV, v_off_fin = 1832.318 uV 18:15:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -38.713 uVs 18:15:58 I1X Average and RMS of Measurements VT = 31.208 +- 9.093 uVs I1X = -6.241 +- 1.818 uTm 18:16:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:16:05 Integrated Voltage Measurement... 18:16:14 Voltage Offset Correction: v_off_ini = 1852.668 uV, v_off_fin = 1835.984 uV 18:16:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -242.961 uVs 18:16:14 Integrated Voltage Measurement... 18:16:23 Voltage Offset Correction: v_off_ini = 1842.983 uV, v_off_fin = 1859.589 uV 18:16:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.051 uVs 18:16:23 Integrated Voltage Measurement... 18:16:32 Voltage Offset Correction: v_off_ini = 1847.322 uV, v_off_fin = 1822.897 uV 18:16:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.306 uVs 18:16:32 Integrated Voltage Measurement... 18:16:41 Voltage Offset Correction: v_off_ini = 1841.449 uV, v_off_fin = 1849.589 uV 18:16:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.716 uVs 18:16:41 Integrated Voltage Measurement... 18:16:50 Voltage Offset Correction: v_off_ini = 1852.407 uV, v_off_fin = 1831.002 uV 18:16:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.140 uVs 18:16:50 Integrated Voltage Measurement... 18:16:59 Voltage Offset Correction: v_off_ini = 1858.763 uV, v_off_fin = 1873.797 uV 18:16:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 232.005 uVs 18:17:03 I1Y Average and RMS of Measurements VT = -232.863 +- 8.340 uVs I1Y = -46.572 +- 1.669 uTm 18:17:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:17:10 Integrated Voltage Measurement... 18:17:19 Voltage Offset Correction: v_off_ini = 1830.638 uV, v_off_fin = 1818.372 uV 18:17:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 58.657 uVs 18:17:19 Integrated Voltage Measurement... 18:17:28 Voltage Offset Correction: v_off_ini = 1819.116 uV, v_off_fin = 1834.278 uV 18:17:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -20.029 uVs 18:17:28 Integrated Voltage Measurement... 18:17:37 Voltage Offset Correction: v_off_ini = 1826.057 uV, v_off_fin = 1813.454 uV 18:17:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 25.623 uVs 18:17:37 Integrated Voltage Measurement... 18:17:46 Voltage Offset Correction: v_off_ini = 1849.588 uV, v_off_fin = 1841.665 uV 18:17:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -33.744 uVs 18:17:46 Integrated Voltage Measurement... 18:17:55 Voltage Offset Correction: v_off_ini = 1833.188 uV, v_off_fin = 1823.211 uV 18:17:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 37.931 uVs 18:17:56 Integrated Voltage Measurement... 18:18:04 Voltage Offset Correction: v_off_ini = 1844.015 uV, v_off_fin = 1835.658 uV 18:18:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -25.407 uVs 18:18:07 I2X Average and RMS of Measurements VT = 33.565 +- 4.165 uVs I2X = -3.088 +- 0.383 uTm^2 18:18:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:18:15 Integrated Voltage Measurement... 18:18:23 Voltage Offset Correction: v_off_ini = 1840.342 uV, v_off_fin = 1833.626 uV 18:18:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.702 uVs 18:18:24 Integrated Voltage Measurement... 18:18:33 Voltage Offset Correction: v_off_ini = 1844.179 uV, v_off_fin = 1832.199 uV 18:18:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.956 uVs 18:18:33 Integrated Voltage Measurement... 18:18:42 Voltage Offset Correction: v_off_ini = 1853.093 uV, v_off_fin = 1835.886 uV 18:18:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.491 uVs 18:18:42 Integrated Voltage Measurement... 18:18:51 Voltage Offset Correction: v_off_ini = 1863.274 uV, v_off_fin = 1836.715 uV 18:18:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.787 uVs 18:18:51 Integrated Voltage Measurement... 18:19:00 Voltage Offset Correction: v_off_ini = 1839.179 uV, v_off_fin = 1845.318 uV 18:19:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.475 uVs 18:19:00 Integrated Voltage Measurement... 18:19:09 Voltage Offset Correction: v_off_ini = 1816.279 uV, v_off_fin = 1850.370 uV 18:19:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.372 uVs 18:19:11 I2Y Average and RMS of Measurements VT = -269.130 +- 10.659 uVs I2Y = -24.760 +- 0.981 uTm^2 18:19:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:19:28 Integrated Voltage Measurement... 18:19:37 Voltage Offset Correction: v_off_ini = 1800.325 uV, v_off_fin = 1849.767 uV 18:19:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 26.730 uVs 18:19:37 Integrated Voltage Measurement... 18:19:46 Voltage Offset Correction: v_off_ini = 1849.500 uV, v_off_fin = 1836.064 uV 18:19:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -27.056 uVs 18:19:46 Integrated Voltage Measurement... 18:19:55 Voltage Offset Correction: v_off_ini = 1816.730 uV, v_off_fin = 1805.949 uV 18:19:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 47.050 uVs 18:19:55 Integrated Voltage Measurement... 18:20:04 Voltage Offset Correction: v_off_ini = 1821.499 uV, v_off_fin = 1796.790 uV 18:20:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -10.598 uVs 18:20:04 Integrated Voltage Measurement... 18:20:13 Voltage Offset Correction: v_off_ini = 1832.645 uV, v_off_fin = 1814.267 uV 18:20:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 30.533 uVs 18:20:13 Integrated Voltage Measurement... 18:20:22 Voltage Offset Correction: v_off_ini = 1819.431 uV, v_off_fin = 1819.453 uV 18:20:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -0.645 uVs 18:20:26 I1X Average and RMS of Measurements VT = 23.769 +- 5.838 uVs I1X = -4.754 +- 1.168 uTm 18:20:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:20:33 Integrated Voltage Measurement... 18:20:42 Voltage Offset Correction: v_off_ini = 1826.138 uV, v_off_fin = 1810.498 uV 18:20:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.188 uVs 18:20:42 Integrated Voltage Measurement... 18:20:51 Voltage Offset Correction: v_off_ini = 1821.421 uV, v_off_fin = 1845.096 uV 18:20:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 238.560 uVs 18:20:51 Integrated Voltage Measurement... 18:21:00 Voltage Offset Correction: v_off_ini = 1810.878 uV, v_off_fin = 1780.773 uV 18:21:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -238.657 uVs 18:21:00 Integrated Voltage Measurement... 18:21:09 Voltage Offset Correction: v_off_ini = 1834.019 uV, v_off_fin = 1837.257 uV 18:21:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 255.373 uVs 18:21:09 Integrated Voltage Measurement... 18:21:18 Voltage Offset Correction: v_off_ini = 1843.129 uV, v_off_fin = 1817.908 uV 18:21:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -263.185 uVs 18:21:18 Integrated Voltage Measurement... 18:21:27 Voltage Offset Correction: v_off_ini = 1848.646 uV, v_off_fin = 1815.060 uV 18:21:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 272.502 uVs 18:21:31 I1Y Average and RMS of Measurements VT = -250.077 +- 13.431 uVs I1Y = -50.010 +- 2.684 uTm 18:21:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:21:39 Integrated Voltage Measurement... 18:21:48 Voltage Offset Correction: v_off_ini = 1816.294 uV, v_off_fin = 1830.038 uV 18:21:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 19.025 uVs 18:21:48 Integrated Voltage Measurement... 18:21:57 Voltage Offset Correction: v_off_ini = 1833.693 uV, v_off_fin = 1836.082 uV 18:21:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.823 uVs 18:21:57 Integrated Voltage Measurement... 18:22:06 Voltage Offset Correction: v_off_ini = 1846.240 uV, v_off_fin = 1838.229 uV 18:22:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 14.303 uVs 18:22:06 Integrated Voltage Measurement... 18:22:15 Voltage Offset Correction: v_off_ini = 1852.111 uV, v_off_fin = 1827.060 uV 18:22:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.600 uVs 18:22:15 Integrated Voltage Measurement... 18:22:24 Voltage Offset Correction: v_off_ini = 1862.270 uV, v_off_fin = 1853.384 uV 18:22:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 6.072 uVs 18:22:24 Integrated Voltage Measurement... 18:22:33 Voltage Offset Correction: v_off_ini = 1833.169 uV, v_off_fin = 1841.835 uV 18:22:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -32.897 uVs 18:22:35 I2X Average and RMS of Measurements VT = 11.012 +- 6.528 uVs I2X = -1.013 +- 0.601 uTm^2 18:22:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:22:43 Integrated Voltage Measurement... 18:22:52 Voltage Offset Correction: v_off_ini = 1853.486 uV, v_off_fin = 1840.024 uV 18:22:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.580 uVs 18:22:52 Integrated Voltage Measurement... 18:23:01 Voltage Offset Correction: v_off_ini = 1855.108 uV, v_off_fin = 1825.601 uV 18:23:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.894 uVs 18:23:01 Integrated Voltage Measurement... 18:23:10 Voltage Offset Correction: v_off_ini = 1843.910 uV, v_off_fin = 1831.521 uV 18:23:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.119 uVs 18:23:10 Integrated Voltage Measurement... 18:23:19 Voltage Offset Correction: v_off_ini = 1821.028 uV, v_off_fin = 1837.665 uV 18:23:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.706 uVs 18:23:19 Integrated Voltage Measurement... 18:23:28 Voltage Offset Correction: v_off_ini = 1845.000 uV, v_off_fin = 1853.630 uV 18:23:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -254.845 uVs 18:23:28 Integrated Voltage Measurement... 18:23:37 Voltage Offset Correction: v_off_ini = 1859.803 uV, v_off_fin = 1881.472 uV 18:23:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.866 uVs 18:23:40 I2Y Average and RMS of Measurements VT = -258.335 +- 13.006 uVs I2Y = -23.767 +- 1.196 uTm^2 18:23:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:23:57 Integrated Voltage Measurement... 18:24:06 Voltage Offset Correction: v_off_ini = 1848.004 uV, v_off_fin = 1796.897 uV 18:24:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -33.581 uVs 18:24:06 Integrated Voltage Measurement... 18:24:15 Voltage Offset Correction: v_off_ini = 1867.486 uV, v_off_fin = 1873.378 uV 18:24:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -13.189 uVs 18:24:15 Integrated Voltage Measurement... 18:24:24 Voltage Offset Correction: v_off_ini = 1834.584 uV, v_off_fin = 1803.890 uV 18:24:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -3.999 uVs 18:24:24 Integrated Voltage Measurement... 18:24:33 Voltage Offset Correction: v_off_ini = 1845.676 uV, v_off_fin = 1848.407 uV 18:24:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.617 uVs 18:24:33 Integrated Voltage Measurement... 18:24:42 Voltage Offset Correction: v_off_ini = 1878.480 uV, v_off_fin = 1871.272 uV 18:24:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 21.036 uVs 18:24:42 Integrated Voltage Measurement... 18:24:51 Voltage Offset Correction: v_off_ini = 1843.048 uV, v_off_fin = 1850.877 uV 18:24:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -41.156 uVs 18:24:55 I1X Average and RMS of Measurements VT = 3.031 +- 19.856 uVs I1X = -0.606 +- 3.971 uTm 18:24:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:25:02 Integrated Voltage Measurement... 18:25:11 Voltage Offset Correction: v_off_ini = 1848.438 uV, v_off_fin = 1818.194 uV 18:25:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.922 uVs 18:25:11 Integrated Voltage Measurement... 18:25:20 Voltage Offset Correction: v_off_ini = 1841.764 uV, v_off_fin = 1852.032 uV 18:25:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 223.418 uVs 18:25:20 Integrated Voltage Measurement... 18:25:29 Voltage Offset Correction: v_off_ini = 1843.454 uV, v_off_fin = 1838.015 uV 18:25:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -219.175 uVs 18:25:29 Integrated Voltage Measurement... 18:25:38 Voltage Offset Correction: v_off_ini = 1835.097 uV, v_off_fin = 1850.249 uV 18:25:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.558 uVs 18:25:38 Integrated Voltage Measurement... 18:25:47 Voltage Offset Correction: v_off_ini = 1839.461 uV, v_off_fin = 1828.396 uV 18:25:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -237.861 uVs 18:25:47 Integrated Voltage Measurement... 18:25:56 Voltage Offset Correction: v_off_ini = 1838.832 uV, v_off_fin = 1865.681 uV 18:25:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.822 uVs 18:26:00 I1Y Average and RMS of Measurements VT = -227.459 +- 6.376 uVs I1Y = -45.487 +- 1.275 uTm 18:26:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:26:07 Integrated Voltage Measurement... 18:26:16 Voltage Offset Correction: v_off_ini = 1839.826 uV, v_off_fin = 1865.792 uV 18:26:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.638 uVs 18:26:17 Integrated Voltage Measurement... 18:26:25 Voltage Offset Correction: v_off_ini = 1872.332 uV, v_off_fin = 1899.039 uV 18:26:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.454 uVs 18:26:26 Integrated Voltage Measurement... 18:26:34 Voltage Offset Correction: v_off_ini = 1844.051 uV, v_off_fin = 1818.026 uV 18:26:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.271 uVs 18:26:35 Integrated Voltage Measurement... 18:26:44 Voltage Offset Correction: v_off_ini = 1851.998 uV, v_off_fin = 1881.000 uV 18:26:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -3.809 uVs 18:26:44 Integrated Voltage Measurement... 18:26:53 Voltage Offset Correction: v_off_ini = 1828.750 uV, v_off_fin = 1837.063 uV 18:26:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 34.202 uVs 18:26:53 Integrated Voltage Measurement... 18:27:02 Voltage Offset Correction: v_off_ini = 1862.155 uV, v_off_fin = 1885.792 uV 18:27:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -31.983 uVs 18:27:04 I2X Average and RMS of Measurements VT = 5.105 +- 19.791 uVs I2X = -0.470 +- 1.821 uTm^2 18:27:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:27:12 Integrated Voltage Measurement... 18:27:21 Voltage Offset Correction: v_off_ini = 1855.489 uV, v_off_fin = 1864.836 uV 18:27:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0002 mm dXY = 1.0000 mm VT = -276.000 uVs 18:27:21 Integrated Voltage Measurement... 18:27:30 Voltage Offset Correction: v_off_ini = 1861.113 uV, v_off_fin = 1845.492 uV 18:27:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 256.278 uVs 18:27:30 Integrated Voltage Measurement... 18:27:39 Voltage Offset Correction: v_off_ini = 1828.088 uV, v_off_fin = 1829.844 uV 18:27:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.967 uVs 18:27:39 Integrated Voltage Measurement... 18:27:48 Voltage Offset Correction: v_off_ini = 1842.494 uV, v_off_fin = 1829.076 uV 18:27:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.547 uVs 18:27:48 Integrated Voltage Measurement... 18:27:57 Voltage Offset Correction: v_off_ini = 1814.923 uV, v_off_fin = 1819.060 uV 18:27:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.930 uVs 18:27:57 Integrated Voltage Measurement... 18:28:06 Voltage Offset Correction: v_off_ini = 1816.678 uV, v_off_fin = 1821.201 uV 18:28:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.401 uVs 18:28:08 I2Y Average and RMS of Measurements VT = -267.021 +- 1.228 uVs I2Y = -24.566 +- 0.113 uTm^2 18:28:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:56:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:56:09 Integrated Voltage Measurement... 08:56:18 Voltage Offset Correction: v_off_ini = -291.733 uV, v_off_fin = -284.713 uV 08:56:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 91.472 uVs 08:56:18 Integrated Voltage Measurement... 08:56:27 Voltage Offset Correction: v_off_ini = -290.356 uV, v_off_fin = -287.361 uV 08:56:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -75.999 uVs 08:56:27 Integrated Voltage Measurement... 08:56:36 Voltage Offset Correction: v_off_ini = -287.399 uV, v_off_fin = -287.702 uV 08:56:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 61.100 uVs 08:56:36 Integrated Voltage Measurement... 08:56:45 Voltage Offset Correction: v_off_ini = -289.023 uV, v_off_fin = -305.973 uV 08:56:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -102.334 uVs 08:56:45 Integrated Voltage Measurement... 08:56:54 Voltage Offset Correction: v_off_ini = -299.079 uV, v_off_fin = -285.271 uV 08:56:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 120.747 uVs 08:56:54 Integrated Voltage Measurement... 08:57:03 Voltage Offset Correction: v_off_ini = -287.660 uV, v_off_fin = -275.929 uV 08:57:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -68.208 uVs 08:57:07 I1X Average and RMS of Measurements VT = 86.643 +- 5.601 uVs I1X = -17.329 +- 1.120 uTm 08:57:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:57:14 Integrated Voltage Measurement... 08:57:23 Voltage Offset Correction: v_off_ini = -284.129 uV, v_off_fin = -314.562 uV 08:57:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -219.270 uVs 08:57:23 Integrated Voltage Measurement... 08:57:32 Voltage Offset Correction: v_off_ini = -284.627 uV, v_off_fin = -292.353 uV 08:57:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.113 uVs 08:57:32 Integrated Voltage Measurement... 08:57:41 Voltage Offset Correction: v_off_ini = -285.706 uV, v_off_fin = -314.458 uV 08:57:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -220.422 uVs 08:57:41 Integrated Voltage Measurement... 08:57:50 Voltage Offset Correction: v_off_ini = -278.030 uV, v_off_fin = -287.438 uV 08:57:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.717 uVs 08:57:50 Integrated Voltage Measurement... 08:57:59 Voltage Offset Correction: v_off_ini = -292.250 uV, v_off_fin = -289.962 uV 08:57:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -258.406 uVs 08:57:59 Integrated Voltage Measurement... 08:58:08 Voltage Offset Correction: v_off_ini = -257.652 uV, v_off_fin = -251.342 uV 08:58:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 219.179 uVs 08:58:12 I1Y Average and RMS of Measurements VT = -226.018 +- 9.272 uVs I1Y = -45.199 +- 1.853 uTm 08:58:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:58:20 Integrated Voltage Measurement... 08:58:29 Voltage Offset Correction: v_off_ini = -322.468 uV, v_off_fin = -280.561 uV 08:58:29 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 75.371 uVs 08:58:29 Integrated Voltage Measurement... 08:58:38 Voltage Offset Correction: v_off_ini = -271.457 uV, v_off_fin = -276.390 uV 08:58:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -75.642 uVs 08:58:38 Integrated Voltage Measurement... 08:58:47 Voltage Offset Correction: v_off_ini = -284.967 uV, v_off_fin = -278.804 uV 08:58:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 97.094 uVs 08:58:47 Integrated Voltage Measurement... 08:58:56 Voltage Offset Correction: v_off_ini = -263.709 uV, v_off_fin = -250.212 uV 08:58:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -102.577 uVs 08:58:56 Integrated Voltage Measurement... 08:59:05 Voltage Offset Correction: v_off_ini = -255.294 uV, v_off_fin = -248.049 uV 08:59:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 79.343 uVs 08:59:05 Integrated Voltage Measurement... 08:59:14 Voltage Offset Correction: v_off_ini = -231.531 uV, v_off_fin = -247.028 uV 08:59:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -72.263 uVs 08:59:16 I2X Average and RMS of Measurements VT = 83.715 +- 11.400 uVs I2X = -7.702 +- 1.049 uTm^2 08:59:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:59:24 Integrated Voltage Measurement... 08:59:33 Voltage Offset Correction: v_off_ini = -244.507 uV, v_off_fin = -253.688 uV 08:59:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.045 uVs 08:59:33 Integrated Voltage Measurement... 08:59:42 Voltage Offset Correction: v_off_ini = -235.103 uV, v_off_fin = -245.208 uV 08:59:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.077 uVs 08:59:42 Integrated Voltage Measurement... 08:59:51 Voltage Offset Correction: v_off_ini = -237.844 uV, v_off_fin = -242.649 uV 08:59:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.885 uVs 08:59:51 Integrated Voltage Measurement... 09:00:00 Voltage Offset Correction: v_off_ini = -220.101 uV, v_off_fin = -207.363 uV 09:00:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.547 uVs 09:00:00 Integrated Voltage Measurement... 09:00:09 Voltage Offset Correction: v_off_ini = -221.161 uV, v_off_fin = -248.573 uV 09:00:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -350.515 uVs 09:00:09 Integrated Voltage Measurement... 09:00:18 Voltage Offset Correction: v_off_ini = -210.905 uV, v_off_fin = -211.431 uV 09:00:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.744 uVs 09:00:21 I2Y Average and RMS of Measurements VT = -321.969 +- 14.746 uVs I2Y = -29.621 +- 1.357 uTm^2 09:00:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:00:35 Integrated Voltage Measurement... 09:00:44 Voltage Offset Correction: v_off_ini = -201.379 uV, v_off_fin = -229.880 uV 09:00:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 67.617 uVs 09:00:44 Integrated Voltage Measurement... 09:00:53 Voltage Offset Correction: v_off_ini = -229.639 uV, v_off_fin = -228.304 uV 09:00:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -95.848 uVs 09:00:53 Integrated Voltage Measurement... 09:01:02 Voltage Offset Correction: v_off_ini = -213.417 uV, v_off_fin = -200.073 uV 09:01:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 77.421 uVs 09:01:02 Integrated Voltage Measurement... 09:01:11 Voltage Offset Correction: v_off_ini = -205.415 uV, v_off_fin = -207.399 uV 09:01:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -77.938 uVs 09:01:11 Integrated Voltage Measurement... 09:01:20 Voltage Offset Correction: v_off_ini = -222.679 uV, v_off_fin = -191.898 uV 09:01:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 99.817 uVs 09:01:20 Integrated Voltage Measurement... 09:01:29 Voltage Offset Correction: v_off_ini = -210.261 uV, v_off_fin = -231.305 uV 09:01:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -112.512 uVs 09:01:33 I1X Average and RMS of Measurements VT = 88.525 +- 12.582 uVs I1X = -17.705 +- 2.516 uTm 09:01:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:01:40 Integrated Voltage Measurement... 09:01:49 Voltage Offset Correction: v_off_ini = -191.709 uV, v_off_fin = -207.834 uV 09:01:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -239.463 uVs 09:01:49 Integrated Voltage Measurement... 09:01:58 Voltage Offset Correction: v_off_ini = -179.000 uV, v_off_fin = -160.834 uV 09:01:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 240.426 uVs 09:01:58 Integrated Voltage Measurement... 09:02:07 Voltage Offset Correction: v_off_ini = -184.820 uV, v_off_fin = -209.509 uV 09:02:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -251.835 uVs 09:02:07 Integrated Voltage Measurement... 09:02:16 Voltage Offset Correction: v_off_ini = -185.149 uV, v_off_fin = -181.690 uV 09:02:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 246.165 uVs 09:02:16 Integrated Voltage Measurement... 09:02:25 Voltage Offset Correction: v_off_ini = -187.769 uV, v_off_fin = -190.463 uV 09:02:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -229.637 uVs 09:02:25 Integrated Voltage Measurement... 09:02:34 Voltage Offset Correction: v_off_ini = -175.058 uV, v_off_fin = -159.358 uV 09:02:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 224.402 uVs 09:02:38 I1Y Average and RMS of Measurements VT = -238.655 +- 9.020 uVs I1Y = -47.725 +- 1.802 uTm 09:02:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:02:46 Integrated Voltage Measurement... 09:02:55 Voltage Offset Correction: v_off_ini = -168.747 uV, v_off_fin = -180.429 uV 09:02:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 125.122 uVs 09:02:55 Integrated Voltage Measurement... 09:03:04 Voltage Offset Correction: v_off_ini = -177.745 uV, v_off_fin = -178.831 uV 09:03:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -92.917 uVs 09:03:04 Integrated Voltage Measurement... 09:03:13 Voltage Offset Correction: v_off_ini = -183.937 uV, v_off_fin = -206.958 uV 09:03:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 109.075 uVs 09:03:13 Integrated Voltage Measurement... 09:03:22 Voltage Offset Correction: v_off_ini = -192.920 uV, v_off_fin = -193.706 uV 09:03:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -60.076 uVs 09:03:22 Integrated Voltage Measurement... 09:03:31 Voltage Offset Correction: v_off_ini = -161.436 uV, v_off_fin = -154.211 uV 09:03:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 78.880 uVs 09:03:31 Integrated Voltage Measurement... 09:03:40 Voltage Offset Correction: v_off_ini = -182.213 uV, v_off_fin = -171.201 uV 09:03:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -100.560 uVs 09:03:42 I2X Average and RMS of Measurements VT = 94.438 +- 10.522 uVs I2X = -8.688 +- 0.968 uTm^2 09:03:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:03:50 Integrated Voltage Measurement... 09:03:59 Voltage Offset Correction: v_off_ini = -173.858 uV, v_off_fin = -178.913 uV 09:03:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -368.118 uVs 09:03:59 Integrated Voltage Measurement... 09:04:08 Voltage Offset Correction: v_off_ini = -161.942 uV, v_off_fin = -167.577 uV 09:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.439 uVs 09:04:08 Integrated Voltage Measurement... 09:04:17 Voltage Offset Correction: v_off_ini = -160.036 uV, v_off_fin = -179.503 uV 09:04:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.617 uVs 09:04:17 Integrated Voltage Measurement... 09:04:26 Voltage Offset Correction: v_off_ini = -155.616 uV, v_off_fin = -183.936 uV 09:04:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.077 uVs 09:04:26 Integrated Voltage Measurement... 09:04:35 Voltage Offset Correction: v_off_ini = -153.498 uV, v_off_fin = -192.562 uV 09:04:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -305.814 uVs 09:04:35 Integrated Voltage Measurement... 09:04:44 Voltage Offset Correction: v_off_ini = -181.523 uV, v_off_fin = -160.153 uV 09:04:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.693 uVs 09:04:47 I2Y Average and RMS of Measurements VT = -326.126 +- 8.146 uVs I2Y = -30.005 +- 0.749 uTm^2