SLAC Magnetic Measurements Date: 01-29-2025 Time: 22:05:09 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10088 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 3 Measurement Device: Operator: YL Comment: On Axis 22:05:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:05:19 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 22:05:21 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 22:05:22 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 22:05:24 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 22:05:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:06:03 Integrated Voltage Measurement... 22:06:12 Voltage Offset Correction: v_off_ini = 528.077 uV, v_off_fin = 529.181 uV 22:06:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -131.824 uVs 22:06:12 Integrated Voltage Measurement... 22:06:21 Voltage Offset Correction: v_off_ini = 504.363 uV, v_off_fin = 497.136 uV 22:06:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.960 uVs 22:06:22 Integrated Voltage Measurement... 22:06:31 Voltage Offset Correction: v_off_ini = 496.468 uV, v_off_fin = 513.135 uV 22:06:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.023 uVs 22:06:31 Integrated Voltage Measurement... 22:06:40 Voltage Offset Correction: v_off_ini = 506.418 uV, v_off_fin = 536.176 uV 22:06:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.582 uVs 22:06:40 Integrated Voltage Measurement... 22:06:49 Voltage Offset Correction: v_off_ini = 502.229 uV, v_off_fin = 478.909 uV 22:06:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.086 uVs 22:06:49 Integrated Voltage Measurement... 22:06:58 Voltage Offset Correction: v_off_ini = 512.316 uV, v_off_fin = 516.015 uV 22:06:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.411 uVs 22:07:03 I1X Average and RMS of Measurements VT = -108.148 +- 7.362 uVs I1X = 21.630 +- 1.473 uTm 22:07:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:07:09 Integrated Voltage Measurement... 22:07:18 Voltage Offset Correction: v_off_ini = 559.020 uV, v_off_fin = 530.013 uV 22:07:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.532 uVs 22:07:18 Integrated Voltage Measurement... 22:07:27 Voltage Offset Correction: v_off_ini = 530.993 uV, v_off_fin = 550.844 uV 22:07:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.127 uVs 22:07:27 Integrated Voltage Measurement... 22:07:36 Voltage Offset Correction: v_off_ini = 516.891 uV, v_off_fin = 517.054 uV 22:07:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.298 uVs 22:07:36 Integrated Voltage Measurement... 22:07:45 Voltage Offset Correction: v_off_ini = 532.416 uV, v_off_fin = 548.318 uV 22:07:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 212.432 uVs 22:07:45 Integrated Voltage Measurement... 22:07:54 Voltage Offset Correction: v_off_ini = 528.034 uV, v_off_fin = 511.019 uV 22:07:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.572 uVs 22:07:54 Integrated Voltage Measurement... 22:08:03 Voltage Offset Correction: v_off_ini = 561.910 uV, v_off_fin = 539.006 uV 22:08:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.538 uVs 22:08:08 I1Y Average and RMS of Measurements VT = -210.416 +- 6.311 uVs I1Y = -42.079 +- 1.264 uTm 22:08:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:08:15 Integrated Voltage Measurement... 22:08:24 Voltage Offset Correction: v_off_ini = 535.478 uV, v_off_fin = 525.395 uV 22:08:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.258 uVs 22:08:24 Integrated Voltage Measurement... 22:08:33 Voltage Offset Correction: v_off_ini = 551.591 uV, v_off_fin = 534.954 uV 22:08:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.661 uVs 22:08:33 Integrated Voltage Measurement... 22:08:42 Voltage Offset Correction: v_off_ini = 529.229 uV, v_off_fin = 506.191 uV 22:08:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.238 uVs 22:08:42 Integrated Voltage Measurement... 22:08:51 Voltage Offset Correction: v_off_ini = 499.373 uV, v_off_fin = 536.010 uV 22:08:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.231 uVs 22:08:51 Integrated Voltage Measurement... 22:09:00 Voltage Offset Correction: v_off_ini = 532.921 uV, v_off_fin = 546.241 uV 22:09:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.509 uVs 22:09:01 Integrated Voltage Measurement... 22:09:10 Voltage Offset Correction: v_off_ini = 548.381 uV, v_off_fin = 534.645 uV 22:09:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.733 uVs 22:09:12 I2X Average and RMS of Measurements VT = -110.938 +- 9.724 uVs I2X = 10.206 +- 0.895 uTm^2 22:09:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:09:20 Integrated Voltage Measurement... 22:09:29 Voltage Offset Correction: v_off_ini = 526.689 uV, v_off_fin = 524.798 uV 22:09:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.487 uVs 22:09:29 Integrated Voltage Measurement... 22:09:38 Voltage Offset Correction: v_off_ini = 540.740 uV, v_off_fin = 550.744 uV 22:09:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.393 uVs 22:09:38 Integrated Voltage Measurement... 22:09:47 Voltage Offset Correction: v_off_ini = 550.506 uV, v_off_fin = 507.134 uV 22:09:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.298 uVs 22:09:47 Integrated Voltage Measurement... 22:09:56 Voltage Offset Correction: v_off_ini = 503.918 uV, v_off_fin = 520.693 uV 22:09:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.959 uVs 22:09:56 Integrated Voltage Measurement... 22:10:05 Voltage Offset Correction: v_off_ini = 505.482 uV, v_off_fin = 491.219 uV 22:10:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.422 uVs 22:10:05 Integrated Voltage Measurement... 22:10:14 Voltage Offset Correction: v_off_ini = 494.328 uV, v_off_fin = 510.003 uV 22:10:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.696 uVs 22:10:16 I2Y Average and RMS of Measurements VT = -276.709 +- 6.593 uVs I2Y = -25.457 +- 0.607 uTm^2 22:10:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:10:30 Integrated Voltage Measurement... 22:10:39 Voltage Offset Correction: v_off_ini = 545.735 uV, v_off_fin = 535.767 uV 22:10:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -117.707 uVs 22:10:39 Integrated Voltage Measurement... 22:10:48 Voltage Offset Correction: v_off_ini = 511.194 uV, v_off_fin = 518.682 uV 22:10:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.887 uVs 22:10:48 Integrated Voltage Measurement... 22:10:57 Voltage Offset Correction: v_off_ini = 526.691 uV, v_off_fin = 516.756 uV 22:10:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.267 uVs 22:10:57 Integrated Voltage Measurement... 22:11:06 Voltage Offset Correction: v_off_ini = 520.789 uV, v_off_fin = 530.862 uV 22:11:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.091 uVs 22:11:06 Integrated Voltage Measurement... 22:11:15 Voltage Offset Correction: v_off_ini = 522.799 uV, v_off_fin = 504.595 uV 22:11:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.037 uVs 22:11:15 Integrated Voltage Measurement... 22:11:24 Voltage Offset Correction: v_off_ini = 523.579 uV, v_off_fin = 519.399 uV 22:11:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.321 uVs 22:11:29 I1X Average and RMS of Measurements VT = -108.718 +- 5.265 uVs I1X = 21.744 +- 1.054 uTm 22:11:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:11:35 Integrated Voltage Measurement... 22:11:44 Voltage Offset Correction: v_off_ini = 507.218 uV, v_off_fin = 504.341 uV 22:11:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.167 uVs 22:11:44 Integrated Voltage Measurement... 22:11:53 Voltage Offset Correction: v_off_ini = 523.188 uV, v_off_fin = 524.237 uV 22:11:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 220.106 uVs 22:11:53 Integrated Voltage Measurement... 22:12:02 Voltage Offset Correction: v_off_ini = 551.407 uV, v_off_fin = 536.944 uV 22:12:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -235.200 uVs 22:12:02 Integrated Voltage Measurement... 22:12:11 Voltage Offset Correction: v_off_ini = 535.041 uV, v_off_fin = 550.478 uV 22:12:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.014 uVs 22:12:11 Integrated Voltage Measurement... 22:12:20 Voltage Offset Correction: v_off_ini = 542.252 uV, v_off_fin = 508.956 uV 22:12:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.060 uVs 22:12:20 Integrated Voltage Measurement... 22:12:29 Voltage Offset Correction: v_off_ini = 497.960 uV, v_off_fin = 521.150 uV 22:12:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.581 uVs 22:12:34 I1Y Average and RMS of Measurements VT = -210.521 +- 3.872 uVs I1Y = -42.099 +- 0.774 uTm 22:12:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:12:41 Integrated Voltage Measurement... 22:12:50 Voltage Offset Correction: v_off_ini = 490.473 uV, v_off_fin = 514.795 uV 22:12:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.457 uVs 22:12:50 Integrated Voltage Measurement... 22:12:59 Voltage Offset Correction: v_off_ini = 519.750 uV, v_off_fin = 526.095 uV 22:12:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.482 uVs 22:12:59 Integrated Voltage Measurement... 22:13:08 Voltage Offset Correction: v_off_ini = 513.632 uV, v_off_fin = 477.545 uV 22:13:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.326 uVs 22:13:09 Integrated Voltage Measurement... 22:13:17 Voltage Offset Correction: v_off_ini = 500.715 uV, v_off_fin = 520.322 uV 22:13:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.547 uVs 22:13:18 Integrated Voltage Measurement... 22:13:27 Voltage Offset Correction: v_off_ini = 527.754 uV, v_off_fin = 506.937 uV 22:13:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.435 uVs 22:13:27 Integrated Voltage Measurement... 22:13:36 Voltage Offset Correction: v_off_ini = 543.890 uV, v_off_fin = 494.247 uV 22:13:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.790 uVs 22:13:38 I2X Average and RMS of Measurements VT = -108.673 +- 6.544 uVs I2X = 9.998 +- 0.602 uTm^2 22:13:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:13:46 Integrated Voltage Measurement... 22:13:55 Voltage Offset Correction: v_off_ini = 516.196 uV, v_off_fin = 519.956 uV 22:13:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -254.654 uVs 22:13:55 Integrated Voltage Measurement... 22:14:04 Voltage Offset Correction: v_off_ini = 509.279 uV, v_off_fin = 515.041 uV 22:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.892 uVs 22:14:04 Integrated Voltage Measurement... 22:14:13 Voltage Offset Correction: v_off_ini = 500.986 uV, v_off_fin = 526.139 uV 22:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.032 uVs 22:14:13 Integrated Voltage Measurement... 22:14:22 Voltage Offset Correction: v_off_ini = 524.500 uV, v_off_fin = 505.740 uV 22:14:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.053 uVs 22:14:22 Integrated Voltage Measurement... 22:14:31 Voltage Offset Correction: v_off_ini = 489.094 uV, v_off_fin = 512.931 uV 22:14:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.407 uVs 22:14:31 Integrated Voltage Measurement... 22:14:40 Voltage Offset Correction: v_off_ini = 499.997 uV, v_off_fin = 511.349 uV 22:14:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.072 uVs 22:14:42 I2Y Average and RMS of Measurements VT = -274.685 +- 3.262 uVs I2Y = -25.271 +- 0.300 uTm^2 22:14:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:14:56 Integrated Voltage Measurement... 22:15:05 Voltage Offset Correction: v_off_ini = 507.797 uV, v_off_fin = 507.744 uV 22:15:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -125.355 uVs 22:15:05 Integrated Voltage Measurement... 22:15:14 Voltage Offset Correction: v_off_ini = 507.016 uV, v_off_fin = 514.781 uV 22:15:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.236 uVs 22:15:14 Integrated Voltage Measurement... 22:15:23 Voltage Offset Correction: v_off_ini = 486.726 uV, v_off_fin = 480.631 uV 22:15:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.814 uVs 22:15:23 Integrated Voltage Measurement... 22:15:32 Voltage Offset Correction: v_off_ini = 460.214 uV, v_off_fin = 492.685 uV 22:15:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.665 uVs 22:15:33 Integrated Voltage Measurement... 22:15:41 Voltage Offset Correction: v_off_ini = 496.174 uV, v_off_fin = 502.321 uV 22:15:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.128 uVs 22:15:42 Integrated Voltage Measurement... 22:15:51 Voltage Offset Correction: v_off_ini = 492.042 uV, v_off_fin = 484.380 uV 22:15:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.728 uVs 22:15:55 I1X Average and RMS of Measurements VT = -115.321 +- 9.718 uVs I1X = 23.065 +- 1.944 uTm 22:15:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:16:02 Integrated Voltage Measurement... 22:16:11 Voltage Offset Correction: v_off_ini = 455.149 uV, v_off_fin = 490.294 uV 22:16:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.518 uVs 22:16:11 Integrated Voltage Measurement... 22:16:20 Voltage Offset Correction: v_off_ini = 484.180 uV, v_off_fin = 498.228 uV 22:16:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 207.429 uVs 22:16:20 Integrated Voltage Measurement... 22:16:29 Voltage Offset Correction: v_off_ini = 479.366 uV, v_off_fin = 469.557 uV 22:16:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -194.373 uVs 22:16:29 Integrated Voltage Measurement... 22:16:38 Voltage Offset Correction: v_off_ini = 509.023 uV, v_off_fin = 522.214 uV 22:16:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 201.193 uVs 22:16:38 Integrated Voltage Measurement... 22:16:47 Voltage Offset Correction: v_off_ini = 455.917 uV, v_off_fin = 476.584 uV 22:16:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -195.215 uVs 22:16:47 Integrated Voltage Measurement... 22:16:55 Voltage Offset Correction: v_off_ini = 481.568 uV, v_off_fin = 489.764 uV 22:16:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.254 uVs 22:17:00 I1Y Average and RMS of Measurements VT = -198.164 +- 2.367 uVs I1Y = -39.627 +- 0.473 uTm 22:17:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:17:07 Integrated Voltage Measurement... 22:17:16 Voltage Offset Correction: v_off_ini = 482.427 uV, v_off_fin = 463.974 uV 22:17:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -175.417 uVs 22:17:17 Integrated Voltage Measurement... 22:17:25 Voltage Offset Correction: v_off_ini = 480.728 uV, v_off_fin = 495.364 uV 22:17:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.882 uVs 22:17:26 Integrated Voltage Measurement... 22:17:35 Voltage Offset Correction: v_off_ini = 495.760 uV, v_off_fin = 480.453 uV 22:17:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.626 uVs 22:17:35 Integrated Voltage Measurement... 22:17:44 Voltage Offset Correction: v_off_ini = 482.214 uV, v_off_fin = 488.867 uV 22:17:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.701 uVs 22:17:44 Integrated Voltage Measurement... 22:17:53 Voltage Offset Correction: v_off_ini = 478.748 uV, v_off_fin = 500.580 uV 22:17:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.190 uVs 22:17:53 Integrated Voltage Measurement... 22:18:02 Voltage Offset Correction: v_off_ini = 513.448 uV, v_off_fin = 525.530 uV 22:18:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.986 uVs 22:18:04 I2X Average and RMS of Measurements VT = -139.134 +- 22.206 uVs I2X = 12.800 +- 2.043 uTm^2 22:18:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:18:12 Integrated Voltage Measurement... 22:18:21 Voltage Offset Correction: v_off_ini = 506.040 uV, v_off_fin = 512.505 uV 22:18:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.244 uVs 22:18:21 Integrated Voltage Measurement... 22:18:30 Voltage Offset Correction: v_off_ini = 504.520 uV, v_off_fin = 505.665 uV 22:18:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.067 uVs 22:18:30 Integrated Voltage Measurement... 22:18:39 Voltage Offset Correction: v_off_ini = 510.316 uV, v_off_fin = 509.260 uV 22:18:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.698 uVs 22:18:39 Integrated Voltage Measurement... 22:18:48 Voltage Offset Correction: v_off_ini = 479.479 uV, v_off_fin = 482.809 uV 22:18:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.428 uVs 22:18:48 Integrated Voltage Measurement... 22:18:57 Voltage Offset Correction: v_off_ini = 500.918 uV, v_off_fin = 461.720 uV 22:18:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.609 uVs 22:18:57 Integrated Voltage Measurement... 22:19:06 Voltage Offset Correction: v_off_ini = 459.093 uV, v_off_fin = 472.523 uV 22:19:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.468 uVs 22:19:08 I2Y Average and RMS of Measurements VT = -282.752 +- 7.613 uVs I2Y = -26.013 +- 0.700 uTm^2 22:19:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:19:22 Integrated Voltage Measurement... 22:19:31 Voltage Offset Correction: v_off_ini = 474.192 uV, v_off_fin = 465.776 uV 22:19:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -108.204 uVs 22:19:31 Integrated Voltage Measurement... 22:19:40 Voltage Offset Correction: v_off_ini = 490.541 uV, v_off_fin = 481.617 uV 22:19:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.426 uVs 22:19:40 Integrated Voltage Measurement... 22:19:49 Voltage Offset Correction: v_off_ini = 483.379 uV, v_off_fin = 459.134 uV 22:19:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.305 uVs 22:19:49 Integrated Voltage Measurement... 22:19:58 Voltage Offset Correction: v_off_ini = 499.005 uV, v_off_fin = 485.052 uV 22:19:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.556 uVs 22:19:59 Integrated Voltage Measurement... 22:20:07 Voltage Offset Correction: v_off_ini = 497.501 uV, v_off_fin = 488.528 uV 22:20:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.806 uVs 22:20:08 Integrated Voltage Measurement... 22:20:16 Voltage Offset Correction: v_off_ini = 506.541 uV, v_off_fin = 493.399 uV 22:20:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.629 uVs 22:20:21 I1X Average and RMS of Measurements VT = -115.655 +- 10.608 uVs I1X = 23.131 +- 2.122 uTm 22:20:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:20:28 Integrated Voltage Measurement... 22:20:36 Voltage Offset Correction: v_off_ini = 487.614 uV, v_off_fin = 491.980 uV 22:20:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.878 uVs 22:20:37 Integrated Voltage Measurement... 22:20:45 Voltage Offset Correction: v_off_ini = 503.871 uV, v_off_fin = 492.955 uV 22:20:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.248 uVs 22:20:46 Integrated Voltage Measurement... 22:20:54 Voltage Offset Correction: v_off_ini = 481.500 uV, v_off_fin = 494.594 uV 22:20:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -217.148 uVs 22:20:55 Integrated Voltage Measurement... 22:21:03 Voltage Offset Correction: v_off_ini = 474.758 uV, v_off_fin = 493.995 uV 22:21:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 186.522 uVs 22:21:04 Integrated Voltage Measurement... 22:21:12 Voltage Offset Correction: v_off_ini = 454.279 uV, v_off_fin = 457.621 uV 22:21:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.894 uVs 22:21:13 Integrated Voltage Measurement... 22:21:21 Voltage Offset Correction: v_off_ini = 477.758 uV, v_off_fin = 482.867 uV 22:21:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 202.261 uVs 22:21:26 I1Y Average and RMS of Measurements VT = -212.992 +- 10.238 uVs I1Y = -42.593 +- 2.050 uTm 22:21:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:21:33 Integrated Voltage Measurement... 22:21:42 Voltage Offset Correction: v_off_ini = 483.669 uV, v_off_fin = 476.532 uV 22:21:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.880 uVs 22:21:42 Integrated Voltage Measurement... 22:21:51 Voltage Offset Correction: v_off_ini = 503.225 uV, v_off_fin = 500.412 uV 22:21:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.250 uVs 22:21:52 Integrated Voltage Measurement... 22:22:00 Voltage Offset Correction: v_off_ini = 494.388 uV, v_off_fin = 491.679 uV 22:22:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.082 uVs 22:22:01 Integrated Voltage Measurement... 22:22:10 Voltage Offset Correction: v_off_ini = 487.248 uV, v_off_fin = 509.104 uV 22:22:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.277 uVs 22:22:10 Integrated Voltage Measurement... 22:22:19 Voltage Offset Correction: v_off_ini = 490.813 uV, v_off_fin = 497.674 uV 22:22:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.208 uVs 22:22:19 Integrated Voltage Measurement... 22:22:28 Voltage Offset Correction: v_off_ini = 494.574 uV, v_off_fin = 518.290 uV 22:22:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.807 uVs 22:22:30 I2X Average and RMS of Measurements VT = -135.917 +- 10.693 uVs I2X = 12.504 +- 0.984 uTm^2 22:22:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:22:38 Integrated Voltage Measurement... 22:22:47 Voltage Offset Correction: v_off_ini = 478.875 uV, v_off_fin = 472.721 uV 22:22:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.089 uVs 22:22:47 Integrated Voltage Measurement... 22:22:56 Voltage Offset Correction: v_off_ini = 471.994 uV, v_off_fin = 527.205 uV 22:22:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.472 uVs 22:22:56 Integrated Voltage Measurement... 22:23:05 Voltage Offset Correction: v_off_ini = 500.862 uV, v_off_fin = 520.663 uV 22:23:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.396 uVs 22:23:05 Integrated Voltage Measurement... 22:23:14 Voltage Offset Correction: v_off_ini = 476.477 uV, v_off_fin = 490.273 uV 22:23:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.879 uVs 22:23:14 Integrated Voltage Measurement... 22:23:23 Voltage Offset Correction: v_off_ini = 478.496 uV, v_off_fin = 501.664 uV 22:23:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.375 uVs 22:23:23 Integrated Voltage Measurement... 22:23:32 Voltage Offset Correction: v_off_ini = 497.117 uV, v_off_fin = 472.330 uV 22:23:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.018 uVs 22:23:34 I2Y Average and RMS of Measurements VT = -277.872 +- 11.936 uVs I2Y = -25.564 +- 1.098 uTm^2 22:23:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:23:48 Integrated Voltage Measurement... 22:23:57 Voltage Offset Correction: v_off_ini = 535.108 uV, v_off_fin = 523.867 uV 22:23:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -141.557 uVs 22:23:57 Integrated Voltage Measurement... 22:24:06 Voltage Offset Correction: v_off_ini = 514.352 uV, v_off_fin = 525.437 uV 22:24:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.137 uVs 22:24:06 Integrated Voltage Measurement... 22:24:15 Voltage Offset Correction: v_off_ini = 521.536 uV, v_off_fin = 521.147 uV 22:24:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.817 uVs 22:24:15 Integrated Voltage Measurement... 22:24:24 Voltage Offset Correction: v_off_ini = 512.854 uV, v_off_fin = 502.850 uV 22:24:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.759 uVs 22:24:24 Integrated Voltage Measurement... 22:24:33 Voltage Offset Correction: v_off_ini = 503.747 uV, v_off_fin = 476.522 uV 22:24:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.162 uVs 22:24:33 Integrated Voltage Measurement... 22:24:42 Voltage Offset Correction: v_off_ini = 507.500 uV, v_off_fin = 520.595 uV 22:24:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.478 uVs 22:24:47 I1X Average and RMS of Measurements VT = -136.318 +- 1.620 uVs I1X = 27.264 +- 0.324 uTm 22:24:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:24:53 Integrated Voltage Measurement... 22:25:02 Voltage Offset Correction: v_off_ini = 513.438 uV, v_off_fin = 500.051 uV 22:25:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.628 uVs 22:25:02 Integrated Voltage Measurement... 22:25:11 Voltage Offset Correction: v_off_ini = 482.795 uV, v_off_fin = 486.481 uV 22:25:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 237.464 uVs 22:25:11 Integrated Voltage Measurement... 22:25:20 Voltage Offset Correction: v_off_ini = 497.461 uV, v_off_fin = 453.344 uV 22:25:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -232.870 uVs 22:25:20 Integrated Voltage Measurement... 22:25:29 Voltage Offset Correction: v_off_ini = 464.662 uV, v_off_fin = 487.203 uV 22:25:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.177 uVs 22:25:29 Integrated Voltage Measurement... 22:25:38 Voltage Offset Correction: v_off_ini = 461.378 uV, v_off_fin = 459.239 uV 22:25:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.616 uVs 22:25:38 Integrated Voltage Measurement... 22:25:47 Voltage Offset Correction: v_off_ini = 459.858 uV, v_off_fin = 459.064 uV 22:25:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 204.424 uVs 22:25:52 I1Y Average and RMS of Measurements VT = -218.863 +- 16.043 uVs I1Y = -43.767 +- 3.209 uTm 22:25:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:25:59 Integrated Voltage Measurement... 22:26:08 Voltage Offset Correction: v_off_ini = 459.322 uV, v_off_fin = 492.956 uV 22:26:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.790 uVs 22:26:08 Integrated Voltage Measurement... 22:26:17 Voltage Offset Correction: v_off_ini = 513.291 uV, v_off_fin = 497.773 uV 22:26:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.335 uVs 22:26:17 Integrated Voltage Measurement... 22:26:26 Voltage Offset Correction: v_off_ini = 476.523 uV, v_off_fin = 483.118 uV 22:26:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.634 uVs 22:26:26 Integrated Voltage Measurement... 22:26:35 Voltage Offset Correction: v_off_ini = 503.344 uV, v_off_fin = 498.625 uV 22:26:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.388 uVs 22:26:35 Integrated Voltage Measurement... 22:26:44 Voltage Offset Correction: v_off_ini = 496.414 uV, v_off_fin = 483.903 uV 22:26:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.654 uVs 22:26:44 Integrated Voltage Measurement... 22:26:53 Voltage Offset Correction: v_off_ini = 478.730 uV, v_off_fin = 507.114 uV 22:26:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.438 uVs 22:26:56 I2X Average and RMS of Measurements VT = -129.206 +- 4.591 uVs I2X = 11.887 +- 0.422 uTm^2 22:27:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:27:04 Integrated Voltage Measurement... 22:27:12 Voltage Offset Correction: v_off_ini = 489.926 uV, v_off_fin = 514.517 uV 22:27:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.734 uVs 22:27:13 Integrated Voltage Measurement... 22:27:22 Voltage Offset Correction: v_off_ini = 483.601 uV, v_off_fin = 496.761 uV 22:27:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.442 uVs 22:27:22 Integrated Voltage Measurement... 22:27:31 Voltage Offset Correction: v_off_ini = 465.480 uV, v_off_fin = 470.325 uV 22:27:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.766 uVs 22:27:31 Integrated Voltage Measurement... 22:27:40 Voltage Offset Correction: v_off_ini = 490.645 uV, v_off_fin = 463.144 uV 22:27:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.865 uVs 22:27:40 Integrated Voltage Measurement... 22:27:49 Voltage Offset Correction: v_off_ini = 497.812 uV, v_off_fin = 474.827 uV 22:27:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.423 uVs 22:27:49 Integrated Voltage Measurement... 22:27:58 Voltage Offset Correction: v_off_ini = 492.948 uV, v_off_fin = 495.979 uV 22:27:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.237 uVs 22:28:00 I2Y Average and RMS of Measurements VT = -271.244 +- 10.717 uVs I2Y = -24.954 +- 0.986 uTm^2 22:28:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:28:14 Integrated Voltage Measurement... 22:28:23 Voltage Offset Correction: v_off_ini = 516.971 uV, v_off_fin = 499.746 uV 22:28:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -127.927 uVs 22:28:23 Integrated Voltage Measurement... 22:28:32 Voltage Offset Correction: v_off_ini = 508.236 uV, v_off_fin = 510.790 uV 22:28:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.285 uVs 22:28:32 Integrated Voltage Measurement... 22:28:41 Voltage Offset Correction: v_off_ini = 513.966 uV, v_off_fin = 514.013 uV 22:28:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.955 uVs 22:28:41 Integrated Voltage Measurement... 22:28:50 Voltage Offset Correction: v_off_ini = 489.191 uV, v_off_fin = 501.600 uV 22:28:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.079 uVs 22:28:50 Integrated Voltage Measurement... 22:28:59 Voltage Offset Correction: v_off_ini = 495.430 uV, v_off_fin = 496.284 uV 22:28:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.627 uVs 22:28:59 Integrated Voltage Measurement... 22:29:08 Voltage Offset Correction: v_off_ini = 518.607 uV, v_off_fin = 518.956 uV 22:29:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.406 uVs 22:29:12 I1X Average and RMS of Measurements VT = -124.713 +- 5.911 uVs I1X = 24.943 +- 1.182 uTm 22:29:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:29:19 Integrated Voltage Measurement... 22:29:28 Voltage Offset Correction: v_off_ini = 517.907 uV, v_off_fin = 502.371 uV 22:29:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -207.526 uVs 22:29:28 Integrated Voltage Measurement... 22:29:37 Voltage Offset Correction: v_off_ini = 521.866 uV, v_off_fin = 520.911 uV 22:29:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 187.194 uVs 22:29:37 Integrated Voltage Measurement... 22:29:46 Voltage Offset Correction: v_off_ini = 503.605 uV, v_off_fin = 480.229 uV 22:29:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -184.736 uVs 22:29:46 Integrated Voltage Measurement... 22:29:55 Voltage Offset Correction: v_off_ini = 513.650 uV, v_off_fin = 525.421 uV 22:29:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 211.399 uVs 22:29:55 Integrated Voltage Measurement... 22:30:04 Voltage Offset Correction: v_off_ini = 525.318 uV, v_off_fin = 501.741 uV 22:30:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.417 uVs 22:30:04 Integrated Voltage Measurement... 22:30:13 Voltage Offset Correction: v_off_ini = 499.011 uV, v_off_fin = 514.155 uV 22:30:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.214 uVs 22:30:17 I1Y Average and RMS of Measurements VT = -202.914 +- 7.360 uVs I1Y = -40.580 +- 1.474 uTm 22:30:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:30:25 Integrated Voltage Measurement... 22:30:34 Voltage Offset Correction: v_off_ini = 511.011 uV, v_off_fin = 514.737 uV 22:30:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.902 uVs 22:30:34 Integrated Voltage Measurement... 22:30:43 Voltage Offset Correction: v_off_ini = 505.055 uV, v_off_fin = 499.866 uV 22:30:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.991 uVs 22:30:43 Integrated Voltage Measurement... 22:30:52 Voltage Offset Correction: v_off_ini = 499.250 uV, v_off_fin = 519.274 uV 22:30:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.866 uVs 22:30:52 Integrated Voltage Measurement... 22:31:01 Voltage Offset Correction: v_off_ini = 500.003 uV, v_off_fin = 520.722 uV 22:31:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.744 uVs 22:31:01 Integrated Voltage Measurement... 22:31:10 Voltage Offset Correction: v_off_ini = 487.338 uV, v_off_fin = 480.031 uV 22:31:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.992 uVs 22:31:10 Integrated Voltage Measurement... 22:31:19 Voltage Offset Correction: v_off_ini = 509.925 uV, v_off_fin = 507.251 uV 22:31:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.427 uVs 22:31:22 I2X Average and RMS of Measurements VT = -142.487 +- 9.977 uVs I2X = 13.109 +- 0.918 uTm^2 22:31:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:31:29 Integrated Voltage Measurement... 22:31:38 Voltage Offset Correction: v_off_ini = 505.736 uV, v_off_fin = 513.270 uV 22:31:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.564 uVs 22:31:38 Integrated Voltage Measurement... 22:31:47 Voltage Offset Correction: v_off_ini = 519.139 uV, v_off_fin = 506.696 uV 22:31:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.843 uVs 22:31:48 Integrated Voltage Measurement... 22:31:57 Voltage Offset Correction: v_off_ini = 502.661 uV, v_off_fin = 503.254 uV 22:31:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.124 uVs 22:31:57 Integrated Voltage Measurement... 22:32:06 Voltage Offset Correction: v_off_ini = 496.865 uV, v_off_fin = 492.405 uV 22:32:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.681 uVs 22:32:06 Integrated Voltage Measurement... 22:32:15 Voltage Offset Correction: v_off_ini = 476.090 uV, v_off_fin = 505.135 uV 22:32:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.740 uVs 22:32:15 Integrated Voltage Measurement... 22:32:24 Voltage Offset Correction: v_off_ini = 535.947 uV, v_off_fin = 513.810 uV 22:32:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.701 uVs 22:32:26 I2Y Average and RMS of Measurements VT = -270.275 +- 8.931 uVs I2Y = -24.865 +- 0.822 uTm^2 22:32:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:32:40 Integrated Voltage Measurement... 22:32:49 Voltage Offset Correction: v_off_ini = 504.628 uV, v_off_fin = 488.597 uV 22:32:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -150.995 uVs 22:32:49 Integrated Voltage Measurement... 22:32:58 Voltage Offset Correction: v_off_ini = 469.568 uV, v_off_fin = 495.052 uV 22:32:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.681 uVs 22:32:58 Integrated Voltage Measurement... 22:33:07 Voltage Offset Correction: v_off_ini = 471.663 uV, v_off_fin = 462.508 uV 22:33:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.760 uVs 22:33:07 Integrated Voltage Measurement... 22:33:16 Voltage Offset Correction: v_off_ini = 505.692 uV, v_off_fin = 518.151 uV 22:33:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.730 uVs 22:33:16 Integrated Voltage Measurement... 22:33:25 Voltage Offset Correction: v_off_ini = 481.802 uV, v_off_fin = 474.328 uV 22:33:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.574 uVs 22:33:25 Integrated Voltage Measurement... 22:33:34 Voltage Offset Correction: v_off_ini = 497.697 uV, v_off_fin = 504.607 uV 22:33:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.255 uVs 22:33:38 I1X Average and RMS of Measurements VT = -122.833 +- 0.770 uVs I1X = 24.568 +- 0.155 uTm 22:33:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:33:45 Integrated Voltage Measurement... 22:33:54 Voltage Offset Correction: v_off_ini = 524.134 uV, v_off_fin = 487.740 uV 22:33:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.725 uVs 22:33:54 Integrated Voltage Measurement... 22:34:03 Voltage Offset Correction: v_off_ini = 496.273 uV, v_off_fin = 505.136 uV 22:34:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.874 uVs 22:34:03 Integrated Voltage Measurement... 22:34:12 Voltage Offset Correction: v_off_ini = 475.649 uV, v_off_fin = 478.339 uV 22:34:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.908 uVs 22:34:12 Integrated Voltage Measurement... 22:34:21 Voltage Offset Correction: v_off_ini = 472.304 uV, v_off_fin = 498.529 uV 22:34:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 235.993 uVs 22:34:21 Integrated Voltage Measurement... 22:34:30 Voltage Offset Correction: v_off_ini = 500.202 uV, v_off_fin = 497.204 uV 22:34:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -216.875 uVs 22:34:30 Integrated Voltage Measurement... 22:34:39 Voltage Offset Correction: v_off_ini = 482.454 uV, v_off_fin = 477.608 uV 22:34:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 208.959 uVs 22:34:43 I1Y Average and RMS of Measurements VT = -218.722 +- 9.012 uVs I1Y = -43.739 +- 1.801 uTm 22:34:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:34:51 Integrated Voltage Measurement... 22:35:00 Voltage Offset Correction: v_off_ini = 481.857 uV, v_off_fin = 467.393 uV 22:35:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.997 uVs 22:35:00 Integrated Voltage Measurement... 22:35:09 Voltage Offset Correction: v_off_ini = 495.535 uV, v_off_fin = 489.621 uV 22:35:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 153.965 uVs 22:35:09 Integrated Voltage Measurement... 22:35:18 Voltage Offset Correction: v_off_ini = 465.512 uV, v_off_fin = 477.303 uV 22:35:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.960 uVs 22:35:18 Integrated Voltage Measurement... 22:35:27 Voltage Offset Correction: v_off_ini = 499.353 uV, v_off_fin = 488.317 uV 22:35:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.194 uVs 22:35:27 Integrated Voltage Measurement... 22:35:36 Voltage Offset Correction: v_off_ini = 485.928 uV, v_off_fin = 473.230 uV 22:35:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.481 uVs 22:35:36 Integrated Voltage Measurement... 22:35:45 Voltage Offset Correction: v_off_ini = 487.309 uV, v_off_fin = 522.940 uV 22:35:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.746 uVs 22:35:47 I2X Average and RMS of Measurements VT = -143.557 +- 5.619 uVs I2X = 13.207 +- 0.517 uTm^2 22:35:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:35:55 Integrated Voltage Measurement... 22:36:04 Voltage Offset Correction: v_off_ini = 488.526 uV, v_off_fin = 484.142 uV 22:36:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.715 uVs 22:36:04 Integrated Voltage Measurement... 22:36:13 Voltage Offset Correction: v_off_ini = 463.240 uV, v_off_fin = 461.916 uV 22:36:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.090 uVs 22:36:13 Integrated Voltage Measurement... 22:36:22 Voltage Offset Correction: v_off_ini = 470.548 uV, v_off_fin = 482.232 uV 22:36:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.124 uVs 22:36:22 Integrated Voltage Measurement... 22:36:31 Voltage Offset Correction: v_off_ini = 502.427 uV, v_off_fin = 470.199 uV 22:36:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.268 uVs 22:36:31 Integrated Voltage Measurement... 22:36:40 Voltage Offset Correction: v_off_ini = 500.772 uV, v_off_fin = 486.165 uV 22:36:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.544 uVs 22:36:40 Integrated Voltage Measurement... 22:36:49 Voltage Offset Correction: v_off_ini = 493.816 uV, v_off_fin = 487.622 uV 22:36:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.199 uVs 22:36:51 I2Y Average and RMS of Measurements VT = -265.157 +- 9.973 uVs I2Y = -24.394 +- 0.917 uTm^2 22:37:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:37:05 Integrated Voltage Measurement... 22:37:14 Voltage Offset Correction: v_off_ini = 497.694 uV, v_off_fin = 487.160 uV 22:37:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.912 uVs 22:37:14 Integrated Voltage Measurement... 22:37:23 Voltage Offset Correction: v_off_ini = 510.161 uV, v_off_fin = 516.755 uV 22:37:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.705 uVs 22:37:23 Integrated Voltage Measurement... 22:37:32 Voltage Offset Correction: v_off_ini = 501.028 uV, v_off_fin = 501.709 uV 22:37:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.282 uVs 22:37:32 Integrated Voltage Measurement... 22:37:41 Voltage Offset Correction: v_off_ini = 512.599 uV, v_off_fin = 482.520 uV 22:37:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.762 uVs 22:37:41 Integrated Voltage Measurement... 22:37:50 Voltage Offset Correction: v_off_ini = 483.429 uV, v_off_fin = 484.048 uV 22:37:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.149 uVs 22:37:50 Integrated Voltage Measurement... 22:37:59 Voltage Offset Correction: v_off_ini = 524.474 uV, v_off_fin = 505.124 uV 22:37:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.950 uVs 22:38:04 I1X Average and RMS of Measurements VT = -127.293 +- 11.510 uVs I1X = 25.459 +- 2.302 uTm 22:38:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:38:10 Integrated Voltage Measurement... 22:38:19 Voltage Offset Correction: v_off_ini = 512.630 uV, v_off_fin = 499.987 uV 22:38:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.014 uVs 22:38:19 Integrated Voltage Measurement... 22:38:28 Voltage Offset Correction: v_off_ini = 518.200 uV, v_off_fin = 536.269 uV 22:38:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.988 uVs 22:38:28 Integrated Voltage Measurement... 22:38:37 Voltage Offset Correction: v_off_ini = 492.643 uV, v_off_fin = 505.559 uV 22:38:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -231.645 uVs 22:38:37 Integrated Voltage Measurement... 22:38:46 Voltage Offset Correction: v_off_ini = 499.577 uV, v_off_fin = 511.055 uV 22:38:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.768 uVs 22:38:46 Integrated Voltage Measurement... 22:38:55 Voltage Offset Correction: v_off_ini = 506.712 uV, v_off_fin = 487.799 uV 22:38:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -239.193 uVs 22:38:55 Integrated Voltage Measurement... 22:39:04 Voltage Offset Correction: v_off_ini = 500.261 uV, v_off_fin = 512.743 uV 22:39:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.027 uVs 22:39:08 I1Y Average and RMS of Measurements VT = -225.772 +- 2.164 uVs I1Y = -45.151 +- 0.434 uTm 22:39:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:39:16 Integrated Voltage Measurement... 22:39:25 Voltage Offset Correction: v_off_ini = 541.981 uV, v_off_fin = 532.953 uV 22:39:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -182.236 uVs 22:39:25 Integrated Voltage Measurement... 22:39:34 Voltage Offset Correction: v_off_ini = 533.651 uV, v_off_fin = 535.415 uV 22:39:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 175.199 uVs 22:39:34 Integrated Voltage Measurement... 22:39:43 Voltage Offset Correction: v_off_ini = 534.250 uV, v_off_fin = 515.258 uV 22:39:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.939 uVs 22:39:43 Integrated Voltage Measurement... 22:39:52 Voltage Offset Correction: v_off_ini = 511.336 uV, v_off_fin = 535.329 uV 22:39:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 194.638 uVs 22:39:52 Integrated Voltage Measurement... 22:40:01 Voltage Offset Correction: v_off_ini = 480.923 uV, v_off_fin = 516.867 uV 22:40:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.228 uVs 22:40:01 Integrated Voltage Measurement... 22:40:10 Voltage Offset Correction: v_off_ini = 527.037 uV, v_off_fin = 516.770 uV 22:40:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 168.606 uVs 22:40:13 I2X Average and RMS of Measurements VT = -166.974 +- 8.330 uVs I2X = 15.362 +- 0.766 uTm^2 22:40:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:40:20 Integrated Voltage Measurement... 22:40:29 Voltage Offset Correction: v_off_ini = 541.181 uV, v_off_fin = 523.165 uV 22:40:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.356 uVs 22:40:29 Integrated Voltage Measurement... 22:40:38 Voltage Offset Correction: v_off_ini = 528.423 uV, v_off_fin = 507.999 uV 22:40:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.834 uVs 22:40:38 Integrated Voltage Measurement... 22:40:47 Voltage Offset Correction: v_off_ini = 502.066 uV, v_off_fin = 505.548 uV 22:40:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.810 uVs 22:40:47 Integrated Voltage Measurement... 22:40:56 Voltage Offset Correction: v_off_ini = 510.717 uV, v_off_fin = 519.312 uV 22:40:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 249.338 uVs 22:40:56 Integrated Voltage Measurement... 22:41:05 Voltage Offset Correction: v_off_ini = 505.272 uV, v_off_fin = 498.830 uV 22:41:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.467 uVs 22:41:05 Integrated Voltage Measurement... 22:41:14 Voltage Offset Correction: v_off_ini = 490.277 uV, v_off_fin = 492.411 uV 22:41:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.310 uVs 22:41:17 I2Y Average and RMS of Measurements VT = -265.186 +- 4.664 uVs I2Y = -24.397 +- 0.429 uTm^2 22:41:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:41:31 Integrated Voltage Measurement... 22:41:40 Voltage Offset Correction: v_off_ini = 520.904 uV, v_off_fin = 495.524 uV 22:41:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.194 uVs 22:41:40 Integrated Voltage Measurement... 22:41:49 Voltage Offset Correction: v_off_ini = 509.448 uV, v_off_fin = 505.436 uV 22:41:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.489 uVs 22:41:49 Integrated Voltage Measurement... 22:41:58 Voltage Offset Correction: v_off_ini = 471.613 uV, v_off_fin = 482.867 uV 22:41:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.676 uVs 22:41:58 Integrated Voltage Measurement... 22:42:07 Voltage Offset Correction: v_off_ini = 499.709 uV, v_off_fin = 487.365 uV 22:42:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.171 uVs 22:42:07 Integrated Voltage Measurement... 22:42:16 Voltage Offset Correction: v_off_ini = 498.077 uV, v_off_fin = 492.278 uV 22:42:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.682 uVs 22:42:16 Integrated Voltage Measurement... 22:42:25 Voltage Offset Correction: v_off_ini = 485.003 uV, v_off_fin = 478.198 uV 22:42:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.153 uVs 22:42:29 I1X Average and RMS of Measurements VT = -142.227 +- 10.042 uVs I1X = 28.445 +- 2.008 uTm 22:42:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:42:36 Integrated Voltage Measurement... 22:42:45 Voltage Offset Correction: v_off_ini = 454.420 uV, v_off_fin = 430.180 uV 22:42:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.674 uVs 22:42:45 Integrated Voltage Measurement... 22:42:54 Voltage Offset Correction: v_off_ini = 472.356 uV, v_off_fin = 463.456 uV 22:42:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.104 uVs 22:42:54 Integrated Voltage Measurement... 22:43:03 Voltage Offset Correction: v_off_ini = 498.735 uV, v_off_fin = 478.010 uV 22:43:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -216.192 uVs 22:43:03 Integrated Voltage Measurement... 22:43:12 Voltage Offset Correction: v_off_ini = 493.751 uV, v_off_fin = 489.600 uV 22:43:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.674 uVs 22:43:12 Integrated Voltage Measurement... 22:43:21 Voltage Offset Correction: v_off_ini = 480.175 uV, v_off_fin = 473.172 uV 22:43:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.485 uVs 22:43:21 Integrated Voltage Measurement... 22:43:30 Voltage Offset Correction: v_off_ini = 471.415 uV, v_off_fin = 471.978 uV 22:43:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.046 uVs 22:43:34 I1Y Average and RMS of Measurements VT = -220.196 +- 6.060 uVs I1Y = -44.036 +- 1.213 uTm 22:43:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:43:42 Integrated Voltage Measurement... 22:43:51 Voltage Offset Correction: v_off_ini = 450.145 uV, v_off_fin = 467.891 uV 22:43:51 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -122.074 uVs 22:43:51 Integrated Voltage Measurement... 22:44:00 Voltage Offset Correction: v_off_ini = 458.188 uV, v_off_fin = 476.379 uV 22:44:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 197.175 uVs 22:44:00 Integrated Voltage Measurement... 22:44:09 Voltage Offset Correction: v_off_ini = 468.531 uV, v_off_fin = 429.820 uV 22:44:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -160.048 uVs 22:44:09 Integrated Voltage Measurement... 22:44:18 Voltage Offset Correction: v_off_ini = 452.334 uV, v_off_fin = 457.922 uV 22:44:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.935 uVs 22:44:18 Integrated Voltage Measurement... 22:44:27 Voltage Offset Correction: v_off_ini = 448.750 uV, v_off_fin = 459.230 uV 22:44:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -163.783 uVs 22:44:27 Integrated Voltage Measurement... 22:44:36 Voltage Offset Correction: v_off_ini = 455.510 uV, v_off_fin = 471.684 uV 22:44:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.103 uVs 22:44:38 I2X Average and RMS of Measurements VT = -148.020 +- 8.630 uVs I2X = 13.617 +- 0.793 uTm^2 22:44:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:44:46 Integrated Voltage Measurement... 22:44:55 Voltage Offset Correction: v_off_ini = 483.981 uV, v_off_fin = 492.484 uV 22:44:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.960 uVs 22:44:55 Integrated Voltage Measurement... 22:45:04 Voltage Offset Correction: v_off_ini = 497.019 uV, v_off_fin = 495.635 uV 22:45:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.816 uVs 22:45:04 Integrated Voltage Measurement... 22:45:13 Voltage Offset Correction: v_off_ini = 476.248 uV, v_off_fin = 494.226 uV 22:45:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.757 uVs 22:45:13 Integrated Voltage Measurement... 22:45:22 Voltage Offset Correction: v_off_ini = 487.699 uV, v_off_fin = 481.874 uV 22:45:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.089 uVs 22:45:22 Integrated Voltage Measurement... 22:45:31 Voltage Offset Correction: v_off_ini = 482.732 uV, v_off_fin = 470.566 uV 22:45:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.905 uVs 22:45:31 Integrated Voltage Measurement... 22:45:40 Voltage Offset Correction: v_off_ini = 458.397 uV, v_off_fin = 455.398 uV 22:45:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.376 uVs 22:45:42 I2Y Average and RMS of Measurements VT = -273.151 +- 9.359 uVs I2Y = -25.130 +- 0.861 uTm^2 22:45:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:45:56 Integrated Voltage Measurement... 22:46:05 Voltage Offset Correction: v_off_ini = 475.323 uV, v_off_fin = 463.479 uV 22:46:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -144.827 uVs 22:46:05 Integrated Voltage Measurement... 22:46:14 Voltage Offset Correction: v_off_ini = 473.916 uV, v_off_fin = 463.667 uV 22:46:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.058 uVs 22:46:14 Integrated Voltage Measurement... 22:46:23 Voltage Offset Correction: v_off_ini = 469.794 uV, v_off_fin = 478.394 uV 22:46:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.760 uVs 22:46:23 Integrated Voltage Measurement... 22:46:32 Voltage Offset Correction: v_off_ini = 454.028 uV, v_off_fin = 437.127 uV 22:46:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.569 uVs 22:46:33 Integrated Voltage Measurement... 22:46:41 Voltage Offset Correction: v_off_ini = 441.670 uV, v_off_fin = 459.997 uV 22:46:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.936 uVs 22:46:42 Integrated Voltage Measurement... 22:46:50 Voltage Offset Correction: v_off_ini = 471.680 uV, v_off_fin = 466.402 uV 22:46:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.864 uVs 22:46:55 I1X Average and RMS of Measurements VT = -148.002 +- 5.050 uVs I1X = 29.601 +- 1.009 uTm 22:46:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:47:02 Integrated Voltage Measurement... 22:47:10 Voltage Offset Correction: v_off_ini = 455.161 uV, v_off_fin = 466.983 uV 22:47:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.259 uVs 22:47:11 Integrated Voltage Measurement... 22:47:19 Voltage Offset Correction: v_off_ini = 473.297 uV, v_off_fin = 482.763 uV 22:47:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 210.384 uVs 22:47:20 Integrated Voltage Measurement... 22:47:28 Voltage Offset Correction: v_off_ini = 477.395 uV, v_off_fin = 450.950 uV 22:47:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.793 uVs 22:47:28 Integrated Voltage Measurement... 22:47:37 Voltage Offset Correction: v_off_ini = 454.806 uV, v_off_fin = 459.258 uV 22:47:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 207.594 uVs 22:47:38 Integrated Voltage Measurement... 22:47:46 Voltage Offset Correction: v_off_ini = 417.909 uV, v_off_fin = 433.830 uV 22:47:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.895 uVs 22:47:47 Integrated Voltage Measurement... 22:47:55 Voltage Offset Correction: v_off_ini = 443.224 uV, v_off_fin = 441.693 uV 22:47:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.019 uVs 22:48:00 I1Y Average and RMS of Measurements VT = -212.824 +- 5.239 uVs I1Y = -42.560 +- 1.047 uTm 22:48:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:48:07 Integrated Voltage Measurement... 22:48:16 Voltage Offset Correction: v_off_ini = 434.337 uV, v_off_fin = 450.232 uV 22:48:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.289 uVs 22:48:16 Integrated Voltage Measurement... 22:48:25 Voltage Offset Correction: v_off_ini = 449.069 uV, v_off_fin = 462.868 uV 22:48:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 169.591 uVs 22:48:25 Integrated Voltage Measurement... 22:48:34 Voltage Offset Correction: v_off_ini = 420.925 uV, v_off_fin = 409.734 uV 22:48:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.716 uVs 22:48:35 Integrated Voltage Measurement... 22:48:43 Voltage Offset Correction: v_off_ini = 439.328 uV, v_off_fin = 467.091 uV 22:48:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.714 uVs 22:48:44 Integrated Voltage Measurement... 22:48:53 Voltage Offset Correction: v_off_ini = 459.945 uV, v_off_fin = 414.456 uV 22:48:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.156 uVs 22:48:53 Integrated Voltage Measurement... 22:49:02 Voltage Offset Correction: v_off_ini = 448.563 uV, v_off_fin = 451.762 uV 22:49:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.096 uVs 22:49:04 I2X Average and RMS of Measurements VT = -150.927 +- 7.285 uVs I2X = 13.885 +- 0.670 uTm^2 22:49:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:49:12 Integrated Voltage Measurement... 22:49:21 Voltage Offset Correction: v_off_ini = 442.560 uV, v_off_fin = 421.056 uV 22:49:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.941 uVs 22:49:21 Integrated Voltage Measurement... 22:49:30 Voltage Offset Correction: v_off_ini = 437.414 uV, v_off_fin = 419.905 uV 22:49:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.549 uVs 22:49:30 Integrated Voltage Measurement... 22:49:39 Voltage Offset Correction: v_off_ini = 423.289 uV, v_off_fin = 426.912 uV 22:49:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.706 uVs 22:49:39 Integrated Voltage Measurement... 22:49:48 Voltage Offset Correction: v_off_ini = 450.758 uV, v_off_fin = 432.673 uV 22:49:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.086 uVs 22:49:48 Integrated Voltage Measurement... 22:49:57 Voltage Offset Correction: v_off_ini = 422.316 uV, v_off_fin = 414.278 uV 22:49:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.585 uVs 22:49:57 Integrated Voltage Measurement... 22:50:06 Voltage Offset Correction: v_off_ini = 442.943 uV, v_off_fin = 436.040 uV 22:50:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.575 uVs 22:50:08 I2Y Average and RMS of Measurements VT = -259.074 +- 5.453 uVs I2Y = -23.835 +- 0.502 uTm^2 22:50:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:50:22 Integrated Voltage Measurement... 22:50:31 Voltage Offset Correction: v_off_ini = 446.809 uV, v_off_fin = 429.114 uV 22:50:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.297 uVs 22:50:31 Integrated Voltage Measurement... 22:50:40 Voltage Offset Correction: v_off_ini = 399.812 uV, v_off_fin = 412.913 uV 22:50:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 174.521 uVs 22:50:40 Integrated Voltage Measurement... 22:50:49 Voltage Offset Correction: v_off_ini = 400.074 uV, v_off_fin = 421.418 uV 22:50:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.005 uVs 22:50:49 Integrated Voltage Measurement... 22:50:58 Voltage Offset Correction: v_off_ini = 426.509 uV, v_off_fin = 432.172 uV 22:50:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.858 uVs 22:50:58 Integrated Voltage Measurement... 22:51:07 Voltage Offset Correction: v_off_ini = 422.249 uV, v_off_fin = 421.695 uV 22:51:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -142.507 uVs 22:51:07 Integrated Voltage Measurement... 22:51:16 Voltage Offset Correction: v_off_ini = 416.332 uV, v_off_fin = 441.077 uV 22:51:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.646 uVs 22:51:21 I1X Average and RMS of Measurements VT = -150.639 +- 4.020 uVs I1X = 30.128 +- 0.803 uTm 22:51:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:51:27 Integrated Voltage Measurement... 22:51:36 Voltage Offset Correction: v_off_ini = 455.909 uV, v_off_fin = 458.481 uV 22:51:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.320 uVs 22:51:36 Integrated Voltage Measurement... 22:51:45 Voltage Offset Correction: v_off_ini = 462.377 uV, v_off_fin = 480.672 uV 22:51:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5002 mm dXY = -0.5000 mm VT = 222.323 uVs 22:51:45 Integrated Voltage Measurement... 22:51:54 Voltage Offset Correction: v_off_ini = 457.705 uV, v_off_fin = 444.399 uV 22:51:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.148 uVs 22:51:54 Integrated Voltage Measurement... 22:52:03 Voltage Offset Correction: v_off_ini = 438.561 uV, v_off_fin = 457.199 uV 22:52:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.920 uVs 22:52:03 Integrated Voltage Measurement... 22:52:12 Voltage Offset Correction: v_off_ini = 465.653 uV, v_off_fin = 447.799 uV 22:52:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.787 uVs 22:52:12 Integrated Voltage Measurement... 22:52:21 Voltage Offset Correction: v_off_ini = 432.720 uV, v_off_fin = 440.911 uV 22:52:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.188 uVs 22:52:26 I1Y Average and RMS of Measurements VT = -215.948 +- 3.822 uVs I1Y = -43.187 +- 0.764 uTm 22:52:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:52:33 Integrated Voltage Measurement... 22:52:42 Voltage Offset Correction: v_off_ini = 418.947 uV, v_off_fin = 426.434 uV 22:52:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.056 uVs 22:52:42 Integrated Voltage Measurement... 22:52:51 Voltage Offset Correction: v_off_ini = 443.422 uV, v_off_fin = 463.021 uV 22:52:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 158.518 uVs 22:52:51 Integrated Voltage Measurement... 22:53:00 Voltage Offset Correction: v_off_ini = 449.438 uV, v_off_fin = 448.465 uV 22:53:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.214 uVs 22:53:00 Integrated Voltage Measurement... 22:53:09 Voltage Offset Correction: v_off_ini = 458.424 uV, v_off_fin = 467.882 uV 22:53:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 164.957 uVs 22:53:09 Integrated Voltage Measurement... 22:53:18 Voltage Offset Correction: v_off_ini = 471.241 uV, v_off_fin = 449.741 uV 22:53:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.371 uVs 22:53:18 Integrated Voltage Measurement... 22:53:27 Voltage Offset Correction: v_off_ini = 468.481 uV, v_off_fin = 482.163 uV 22:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.286 uVs 22:53:30 I2X Average and RMS of Measurements VT = -146.067 +- 2.805 uVs I2X = 13.438 +- 0.258 uTm^2 22:53:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:53:38 Integrated Voltage Measurement... 22:53:47 Voltage Offset Correction: v_off_ini = 467.768 uV, v_off_fin = 464.138 uV 22:53:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.599 uVs 22:53:47 Integrated Voltage Measurement... 22:53:56 Voltage Offset Correction: v_off_ini = 458.932 uV, v_off_fin = 468.392 uV 22:53:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.740 uVs 22:53:56 Integrated Voltage Measurement... 22:54:05 Voltage Offset Correction: v_off_ini = 484.591 uV, v_off_fin = 464.425 uV 22:54:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.195 uVs 22:54:05 Integrated Voltage Measurement... 22:54:14 Voltage Offset Correction: v_off_ini = 464.606 uV, v_off_fin = 458.643 uV 22:54:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.558 uVs 22:54:14 Integrated Voltage Measurement... 22:54:23 Voltage Offset Correction: v_off_ini = 445.166 uV, v_off_fin = 455.707 uV 22:54:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.598 uVs 22:54:23 Integrated Voltage Measurement... 22:54:32 Voltage Offset Correction: v_off_ini = 439.673 uV, v_off_fin = 482.022 uV 22:54:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.788 uVs 22:54:34 I2Y Average and RMS of Measurements VT = -278.746 +- 16.893 uVs I2Y = -25.645 +- 1.554 uTm^2 22:54:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:54:49 Integrated Voltage Measurement... 22:54:58 Voltage Offset Correction: v_off_ini = 468.443 uV, v_off_fin = 456.933 uV 22:54:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.136 uVs 22:54:58 Integrated Voltage Measurement... 22:55:07 Voltage Offset Correction: v_off_ini = 452.757 uV, v_off_fin = 443.311 uV 22:55:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.888 uVs 22:55:07 Integrated Voltage Measurement... 22:55:16 Voltage Offset Correction: v_off_ini = 484.401 uV, v_off_fin = 469.706 uV 22:55:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -133.657 uVs 22:55:16 Integrated Voltage Measurement... 22:55:25 Voltage Offset Correction: v_off_ini = 479.518 uV, v_off_fin = 476.598 uV 22:55:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 137.693 uVs 22:55:25 Integrated Voltage Measurement... 22:55:34 Voltage Offset Correction: v_off_ini = 470.011 uV, v_off_fin = 484.705 uV 22:55:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.585 uVs 22:55:34 Integrated Voltage Measurement... 22:55:43 Voltage Offset Correction: v_off_ini = 479.911 uV, v_off_fin = 460.154 uV 22:55:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 171.264 uVs 22:55:48 I1X Average and RMS of Measurements VT = -141.037 +- 11.430 uVs I1X = 28.208 +- 2.286 uTm 22:55:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:55:54 Integrated Voltage Measurement... 22:56:03 Voltage Offset Correction: v_off_ini = 453.139 uV, v_off_fin = 452.161 uV 22:56:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.997 uVs 22:56:03 Integrated Voltage Measurement... 22:56:12 Voltage Offset Correction: v_off_ini = 484.189 uV, v_off_fin = 486.519 uV 22:56:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.305 uVs 22:56:12 Integrated Voltage Measurement... 22:56:21 Voltage Offset Correction: v_off_ini = 467.268 uV, v_off_fin = 449.267 uV 22:56:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.477 uVs 22:56:21 Integrated Voltage Measurement... 22:56:30 Voltage Offset Correction: v_off_ini = 456.802 uV, v_off_fin = 470.931 uV 22:56:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.424 uVs 22:56:30 Integrated Voltage Measurement... 22:56:39 Voltage Offset Correction: v_off_ini = 460.720 uV, v_off_fin = 436.363 uV 22:56:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.360 uVs 22:56:39 Integrated Voltage Measurement... 22:56:48 Voltage Offset Correction: v_off_ini = 488.312 uV, v_off_fin = 495.249 uV 22:56:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.656 uVs 22:56:53 I1Y Average and RMS of Measurements VT = -212.703 +- 3.933 uVs I1Y = -42.540 +- 0.787 uTm 22:56:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:57:00 Integrated Voltage Measurement... 22:57:09 Voltage Offset Correction: v_off_ini = 463.359 uV, v_off_fin = 460.855 uV 22:57:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.639 uVs 22:57:09 Integrated Voltage Measurement... 22:57:18 Voltage Offset Correction: v_off_ini = 483.656 uV, v_off_fin = 460.413 uV 22:57:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.164 uVs 22:57:18 Integrated Voltage Measurement... 22:57:27 Voltage Offset Correction: v_off_ini = 473.139 uV, v_off_fin = 455.414 uV 22:57:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -164.194 uVs 22:57:27 Integrated Voltage Measurement... 22:57:36 Voltage Offset Correction: v_off_ini = 466.508 uV, v_off_fin = 471.398 uV 22:57:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.337 uVs 22:57:36 Integrated Voltage Measurement... 22:57:45 Voltage Offset Correction: v_off_ini = 460.993 uV, v_off_fin = 438.197 uV 22:57:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -170.658 uVs 22:57:45 Integrated Voltage Measurement... 22:57:54 Voltage Offset Correction: v_off_ini = 444.079 uV, v_off_fin = 448.856 uV 22:57:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 175.410 uVs 22:57:57 I2X Average and RMS of Measurements VT = -159.067 +- 9.899 uVs I2X = 14.634 +- 0.911 uTm^2 22:58:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:58:05 Integrated Voltage Measurement... 22:58:14 Voltage Offset Correction: v_off_ini = 479.578 uV, v_off_fin = 478.390 uV 22:58:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.234 uVs 22:58:14 Integrated Voltage Measurement... 22:58:23 Voltage Offset Correction: v_off_ini = 473.999 uV, v_off_fin = 462.766 uV 22:58:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.320 uVs 22:58:23 Integrated Voltage Measurement... 22:58:32 Voltage Offset Correction: v_off_ini = 474.087 uV, v_off_fin = 484.086 uV 22:58:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.746 uVs 22:58:32 Integrated Voltage Measurement... 22:58:41 Voltage Offset Correction: v_off_ini = 440.746 uV, v_off_fin = 432.690 uV 22:58:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.378 uVs 22:58:41 Integrated Voltage Measurement... 22:58:50 Voltage Offset Correction: v_off_ini = 483.859 uV, v_off_fin = 474.842 uV 22:58:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.970 uVs 22:58:50 Integrated Voltage Measurement... 22:58:59 Voltage Offset Correction: v_off_ini = 483.185 uV, v_off_fin = 485.529 uV 22:58:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.455 uVs 22:59:01 I2Y Average and RMS of Measurements VT = -263.184 +- 15.281 uVs I2Y = -24.213 +- 1.406 uTm^2 22:59:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:59:16 Integrated Voltage Measurement... 22:59:25 Voltage Offset Correction: v_off_ini = 478.714 uV, v_off_fin = 458.802 uV 22:59:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -172.155 uVs 22:59:25 Integrated Voltage Measurement... 22:59:34 Voltage Offset Correction: v_off_ini = 440.953 uV, v_off_fin = 464.736 uV 22:59:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.782 uVs 22:59:34 Integrated Voltage Measurement... 22:59:43 Voltage Offset Correction: v_off_ini = 449.302 uV, v_off_fin = 466.592 uV 22:59:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.558 uVs 22:59:43 Integrated Voltage Measurement... 22:59:52 Voltage Offset Correction: v_off_ini = 472.822 uV, v_off_fin = 475.818 uV 22:59:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.024 uVs 22:59:52 Integrated Voltage Measurement... 23:00:01 Voltage Offset Correction: v_off_ini = 490.086 uV, v_off_fin = 485.877 uV 23:00:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -174.658 uVs 23:00:01 Integrated Voltage Measurement... 23:00:10 Voltage Offset Correction: v_off_ini = 474.917 uV, v_off_fin = 483.518 uV 23:00:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.238 uVs 23:00:15 I1X Average and RMS of Measurements VT = -158.903 +- 5.835 uVs I1X = 31.781 +- 1.167 uTm 23:00:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:00:21 Integrated Voltage Measurement... 23:00:30 Voltage Offset Correction: v_off_ini = 458.905 uV, v_off_fin = 475.573 uV 23:00:30 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -195.669 uVs 23:00:30 Integrated Voltage Measurement... 23:00:39 Voltage Offset Correction: v_off_ini = 477.757 uV, v_off_fin = 482.124 uV 23:00:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.006 uVs 23:00:39 Integrated Voltage Measurement... 23:00:48 Voltage Offset Correction: v_off_ini = 482.797 uV, v_off_fin = 455.774 uV 23:00:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.250 uVs 23:00:48 Integrated Voltage Measurement... 23:00:57 Voltage Offset Correction: v_off_ini = 462.947 uV, v_off_fin = 477.321 uV 23:00:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.355 uVs 23:00:57 Integrated Voltage Measurement... 23:01:06 Voltage Offset Correction: v_off_ini = 461.798 uV, v_off_fin = 466.137 uV 23:01:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.144 uVs 23:01:06 Integrated Voltage Measurement... 23:01:15 Voltage Offset Correction: v_off_ini = 471.813 uV, v_off_fin = 466.655 uV 23:01:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 239.057 uVs 23:01:19 I1Y Average and RMS of Measurements VT = -211.247 +- 5.453 uVs I1Y = -42.248 +- 1.088 uTm 23:01:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:01:27 Integrated Voltage Measurement... 23:01:36 Voltage Offset Correction: v_off_ini = 464.257 uV, v_off_fin = 475.735 uV 23:01:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.101 uVs 23:01:36 Integrated Voltage Measurement... 23:01:45 Voltage Offset Correction: v_off_ini = 458.544 uV, v_off_fin = 475.108 uV 23:01:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 184.485 uVs 23:01:45 Integrated Voltage Measurement... 23:01:54 Voltage Offset Correction: v_off_ini = 465.392 uV, v_off_fin = 450.163 uV 23:01:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -164.322 uVs 23:01:54 Integrated Voltage Measurement... 23:02:03 Voltage Offset Correction: v_off_ini = 440.364 uV, v_off_fin = 457.983 uV 23:02:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 179.799 uVs 23:02:03 Integrated Voltage Measurement... 23:02:12 Voltage Offset Correction: v_off_ini = 461.073 uV, v_off_fin = 422.297 uV 23:02:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -186.344 uVs 23:02:12 Integrated Voltage Measurement... 23:02:21 Voltage Offset Correction: v_off_ini = 424.930 uV, v_off_fin = 448.761 uV 23:02:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 220.647 uVs 23:02:24 I2X Average and RMS of Measurements VT = -180.283 +- 16.644 uVs I2X = 16.586 +- 1.531 uTm^2 23:02:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:02:31 Integrated Voltage Measurement... 23:02:40 Voltage Offset Correction: v_off_ini = 439.827 uV, v_off_fin = 476.079 uV 23:02:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.766 uVs 23:02:41 Integrated Voltage Measurement... 23:02:50 Voltage Offset Correction: v_off_ini = 441.359 uV, v_off_fin = 440.430 uV 23:02:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.485 uVs 23:02:50 Integrated Voltage Measurement... 23:02:59 Voltage Offset Correction: v_off_ini = 451.340 uV, v_off_fin = 454.295 uV 23:02:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.410 uVs 23:02:59 Integrated Voltage Measurement... 23:03:08 Voltage Offset Correction: v_off_ini = 480.320 uV, v_off_fin = 469.602 uV 23:03:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.650 uVs 23:03:08 Integrated Voltage Measurement... 23:03:17 Voltage Offset Correction: v_off_ini = 476.787 uV, v_off_fin = 476.765 uV 23:03:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.685 uVs 23:03:17 Integrated Voltage Measurement... 23:03:26 Voltage Offset Correction: v_off_ini = 465.661 uV, v_off_fin = 455.400 uV 23:03:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.585 uVs 23:03:28 I2Y Average and RMS of Measurements VT = -255.264 +- 5.790 uVs I2Y = -23.484 +- 0.533 uTm^2 23:03:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:03:46 Integrated Voltage Measurement... 23:03:55 Voltage Offset Correction: v_off_ini = 469.661 uV, v_off_fin = 473.038 uV 23:03:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -140.301 uVs 23:03:55 Integrated Voltage Measurement... 23:04:04 Voltage Offset Correction: v_off_ini = 467.640 uV, v_off_fin = 476.875 uV 23:04:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.045 uVs 23:04:04 Integrated Voltage Measurement... 23:04:13 Voltage Offset Correction: v_off_ini = 471.999 uV, v_off_fin = 460.176 uV 23:04:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.310 uVs 23:04:13 Integrated Voltage Measurement... 23:04:22 Voltage Offset Correction: v_off_ini = 449.461 uV, v_off_fin = 453.248 uV 23:04:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.086 uVs 23:04:22 Integrated Voltage Measurement... 23:04:31 Voltage Offset Correction: v_off_ini = 472.461 uV, v_off_fin = 448.807 uV 23:04:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.021 uVs 23:04:31 Integrated Voltage Measurement... 23:04:40 Voltage Offset Correction: v_off_ini = 444.489 uV, v_off_fin = 464.980 uV 23:04:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.433 uVs 23:04:44 I1X Average and RMS of Measurements VT = -164.533 +- 8.004 uVs I1X = 32.907 +- 1.600 uTm 23:04:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:04:51 Integrated Voltage Measurement... 23:05:00 Voltage Offset Correction: v_off_ini = 438.512 uV, v_off_fin = 453.620 uV 23:05:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -149.594 uVs 23:05:00 Integrated Voltage Measurement... 23:05:09 Voltage Offset Correction: v_off_ini = 482.637 uV, v_off_fin = 514.166 uV 23:05:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.065 uVs 23:05:09 Integrated Voltage Measurement... 23:05:18 Voltage Offset Correction: v_off_ini = 473.717 uV, v_off_fin = 499.304 uV 23:05:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.635 uVs 23:05:18 Integrated Voltage Measurement... 23:05:27 Voltage Offset Correction: v_off_ini = 485.423 uV, v_off_fin = 507.693 uV 23:05:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.103 uVs 23:05:27 Integrated Voltage Measurement... 23:05:36 Voltage Offset Correction: v_off_ini = 483.563 uV, v_off_fin = 474.498 uV 23:05:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.132 uVs 23:05:36 Integrated Voltage Measurement... 23:05:45 Voltage Offset Correction: v_off_ini = 481.575 uV, v_off_fin = 497.350 uV 23:05:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 203.208 uVs 23:05:49 I1Y Average and RMS of Measurements VT = -200.623 +- 20.276 uVs I1Y = -40.122 +- 4.054 uTm 23:05:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:05:57 Integrated Voltage Measurement... 23:06:05 Voltage Offset Correction: v_off_ini = 481.505 uV, v_off_fin = 486.670 uV 23:06:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -189.791 uVs 23:06:06 Integrated Voltage Measurement... 23:06:15 Voltage Offset Correction: v_off_ini = 458.246 uV, v_off_fin = 448.854 uV 23:06:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 190.684 uVs 23:06:15 Integrated Voltage Measurement... 23:06:24 Voltage Offset Correction: v_off_ini = 448.720 uV, v_off_fin = 464.561 uV 23:06:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -207.207 uVs 23:06:24 Integrated Voltage Measurement... 23:06:33 Voltage Offset Correction: v_off_ini = 469.548 uV, v_off_fin = 475.861 uV 23:06:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 194.483 uVs 23:06:33 Integrated Voltage Measurement... 23:06:42 Voltage Offset Correction: v_off_ini = 452.291 uV, v_off_fin = 468.107 uV 23:06:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -178.925 uVs 23:06:42 Integrated Voltage Measurement... 23:06:51 Voltage Offset Correction: v_off_ini = 494.732 uV, v_off_fin = 497.801 uV 23:06:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 163.712 uVs 23:06:53 I2X Average and RMS of Measurements VT = -187.467 +- 12.212 uVs I2X = 17.247 +- 1.124 uTm^2 23:06:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:07:01 Integrated Voltage Measurement... 23:07:10 Voltage Offset Correction: v_off_ini = 442.322 uV, v_off_fin = 455.855 uV 23:07:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.352 uVs 23:07:10 Integrated Voltage Measurement... 23:07:19 Voltage Offset Correction: v_off_ini = 472.721 uV, v_off_fin = 452.825 uV 23:07:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.667 uVs 23:07:19 Integrated Voltage Measurement... 23:07:28 Voltage Offset Correction: v_off_ini = 456.821 uV, v_off_fin = 461.150 uV 23:07:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.127 uVs 23:07:28 Integrated Voltage Measurement... 23:07:37 Voltage Offset Correction: v_off_ini = 467.098 uV, v_off_fin = 489.435 uV 23:07:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.658 uVs 23:07:37 Integrated Voltage Measurement... 23:07:46 Voltage Offset Correction: v_off_ini = 475.910 uV, v_off_fin = 483.285 uV 23:07:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.080 uVs 23:07:46 Integrated Voltage Measurement... 23:07:55 Voltage Offset Correction: v_off_ini = 473.419 uV, v_off_fin = 476.480 uV 23:07:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.508 uVs 23:07:57 I2Y Average and RMS of Measurements VT = -259.565 +- 5.932 uVs I2Y = -23.880 +- 0.546 uTm^2 23:08:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:08:15 Integrated Voltage Measurement... 23:08:24 Voltage Offset Correction: v_off_ini = 466.018 uV, v_off_fin = 455.575 uV 23:08:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -152.044 uVs 23:08:24 Integrated Voltage Measurement... 23:08:33 Voltage Offset Correction: v_off_ini = 454.017 uV, v_off_fin = 452.953 uV 23:08:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.199 uVs 23:08:33 Integrated Voltage Measurement... 23:08:42 Voltage Offset Correction: v_off_ini = 457.200 uV, v_off_fin = 463.754 uV 23:08:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -168.905 uVs 23:08:42 Integrated Voltage Measurement... 23:08:51 Voltage Offset Correction: v_off_ini = 461.083 uV, v_off_fin = 438.050 uV 23:08:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.436 uVs 23:08:51 Integrated Voltage Measurement... 23:09:00 Voltage Offset Correction: v_off_ini = 474.021 uV, v_off_fin = 452.265 uV 23:09:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.578 uVs 23:09:00 Integrated Voltage Measurement... 23:09:09 Voltage Offset Correction: v_off_ini = 452.599 uV, v_off_fin = 459.040 uV 23:09:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.396 uVs 23:09:13 I1X Average and RMS of Measurements VT = -159.593 +- 1.406 uVs I1X = 31.919 +- 0.281 uTm 23:09:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:09:20 Integrated Voltage Measurement... 23:09:29 Voltage Offset Correction: v_off_ini = 454.246 uV, v_off_fin = 454.720 uV 23:09:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.138 uVs 23:09:29 Integrated Voltage Measurement... 23:09:38 Voltage Offset Correction: v_off_ini = 450.446 uV, v_off_fin = 473.276 uV 23:09:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.487 uVs 23:09:38 Integrated Voltage Measurement... 23:09:47 Voltage Offset Correction: v_off_ini = 446.349 uV, v_off_fin = 430.653 uV 23:09:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.517 uVs 23:09:47 Integrated Voltage Measurement... 23:09:56 Voltage Offset Correction: v_off_ini = 460.040 uV, v_off_fin = 474.506 uV 23:09:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.777 uVs 23:09:56 Integrated Voltage Measurement... 23:10:05 Voltage Offset Correction: v_off_ini = 442.662 uV, v_off_fin = 431.078 uV 23:10:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.673 uVs 23:10:05 Integrated Voltage Measurement... 23:10:14 Voltage Offset Correction: v_off_ini = 456.888 uV, v_off_fin = 446.364 uV 23:10:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 198.429 uVs 23:10:18 I1Y Average and RMS of Measurements VT = -204.004 +- 10.885 uVs I1Y = -40.797 +- 2.178 uTm 23:10:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:10:26 Integrated Voltage Measurement... 23:10:35 Voltage Offset Correction: v_off_ini = 447.137 uV, v_off_fin = 432.049 uV 23:10:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -180.381 uVs 23:10:35 Integrated Voltage Measurement... 23:10:44 Voltage Offset Correction: v_off_ini = 449.623 uV, v_off_fin = 469.433 uV 23:10:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 214.671 uVs 23:10:44 Integrated Voltage Measurement... 23:10:53 Voltage Offset Correction: v_off_ini = 456.060 uV, v_off_fin = 451.814 uV 23:10:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -185.467 uVs 23:10:53 Integrated Voltage Measurement... 23:11:02 Voltage Offset Correction: v_off_ini = 464.795 uV, v_off_fin = 462.147 uV 23:11:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 193.481 uVs 23:11:02 Integrated Voltage Measurement... 23:11:11 Voltage Offset Correction: v_off_ini = 464.339 uV, v_off_fin = 459.162 uV 23:11:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -181.218 uVs 23:11:11 Integrated Voltage Measurement... 23:11:20 Voltage Offset Correction: v_off_ini = 444.440 uV, v_off_fin = 459.139 uV 23:11:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 183.002 uVs 23:11:22 I2X Average and RMS of Measurements VT = -189.703 +- 6.296 uVs I2X = 17.453 +- 0.579 uTm^2 23:11:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:11:30 Integrated Voltage Measurement... 23:11:39 Voltage Offset Correction: v_off_ini = 462.758 uV, v_off_fin = 442.929 uV 23:11:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.795 uVs 23:11:39 Integrated Voltage Measurement... 23:11:48 Voltage Offset Correction: v_off_ini = 455.096 uV, v_off_fin = 449.306 uV 23:11:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.948 uVs 23:11:48 Integrated Voltage Measurement... 23:11:57 Voltage Offset Correction: v_off_ini = 422.267 uV, v_off_fin = 444.380 uV 23:11:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.342 uVs 23:11:57 Integrated Voltage Measurement... 23:12:06 Voltage Offset Correction: v_off_ini = 423.436 uV, v_off_fin = 452.225 uV 23:12:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.432 uVs 23:12:06 Integrated Voltage Measurement... 23:12:15 Voltage Offset Correction: v_off_ini = 465.376 uV, v_off_fin = 455.898 uV 23:12:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.374 uVs 23:12:15 Integrated Voltage Measurement... 23:12:24 Voltage Offset Correction: v_off_ini = 456.443 uV, v_off_fin = 470.926 uV 23:12:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.336 uVs 23:12:27 I2Y Average and RMS of Measurements VT = -271.871 +- 4.008 uVs I2Y = -25.012 +- 0.369 uTm^2 23:12:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:12:44 Integrated Voltage Measurement... 23:12:53 Voltage Offset Correction: v_off_ini = 454.533 uV, v_off_fin = 453.898 uV 23:12:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.155 uVs 23:12:53 Integrated Voltage Measurement... 23:13:02 Voltage Offset Correction: v_off_ini = 468.277 uV, v_off_fin = 447.888 uV 23:13:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.577 uVs 23:13:02 Integrated Voltage Measurement... 23:13:11 Voltage Offset Correction: v_off_ini = 424.237 uV, v_off_fin = 446.196 uV 23:13:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.707 uVs 23:13:11 Integrated Voltage Measurement... 23:13:20 Voltage Offset Correction: v_off_ini = 463.095 uV, v_off_fin = 434.452 uV 23:13:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 187.223 uVs 23:13:20 Integrated Voltage Measurement... 23:13:29 Voltage Offset Correction: v_off_ini = 451.699 uV, v_off_fin = 455.764 uV 23:13:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.432 uVs 23:13:29 Integrated Voltage Measurement... 23:13:38 Voltage Offset Correction: v_off_ini = 438.488 uV, v_off_fin = 447.725 uV 23:13:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 199.714 uVs 23:13:42 I1X Average and RMS of Measurements VT = -169.801 +- 15.915 uVs I1X = 33.960 +- 3.183 uTm 23:13:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:13:49 Integrated Voltage Measurement... 23:13:58 Voltage Offset Correction: v_off_ini = 448.759 uV, v_off_fin = 437.965 uV 23:13:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.742 uVs 23:13:58 Integrated Voltage Measurement... 23:14:07 Voltage Offset Correction: v_off_ini = 444.686 uV, v_off_fin = 467.063 uV 23:14:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5002 mm dXY = -0.5000 mm VT = 230.767 uVs 23:14:07 Integrated Voltage Measurement... 23:14:16 Voltage Offset Correction: v_off_ini = 461.117 uV, v_off_fin = 451.399 uV 23:14:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.924 uVs 23:14:16 Integrated Voltage Measurement... 23:14:25 Voltage Offset Correction: v_off_ini = 440.434 uV, v_off_fin = 430.426 uV 23:14:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 215.939 uVs 23:14:25 Integrated Voltage Measurement... 23:14:34 Voltage Offset Correction: v_off_ini = 434.786 uV, v_off_fin = 417.635 uV 23:14:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.246 uVs 23:14:34 Integrated Voltage Measurement... 23:14:43 Voltage Offset Correction: v_off_ini = 427.716 uV, v_off_fin = 442.760 uV 23:14:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.368 uVs 23:14:47 I1Y Average and RMS of Measurements VT = -225.998 +- 2.853 uVs I1Y = -45.196 +- 0.570 uTm 23:14:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:14:55 Integrated Voltage Measurement... 23:15:04 Voltage Offset Correction: v_off_ini = 439.929 uV, v_off_fin = 428.159 uV 23:15:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -176.722 uVs 23:15:04 Integrated Voltage Measurement... 23:15:13 Voltage Offset Correction: v_off_ini = 443.287 uV, v_off_fin = 461.654 uV 23:15:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 202.440 uVs 23:15:13 Integrated Voltage Measurement... 23:15:22 Voltage Offset Correction: v_off_ini = 463.148 uV, v_off_fin = 463.639 uV 23:15:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -207.592 uVs 23:15:22 Integrated Voltage Measurement... 23:15:31 Voltage Offset Correction: v_off_ini = 463.995 uV, v_off_fin = 468.634 uV 23:15:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 186.160 uVs 23:15:31 Integrated Voltage Measurement... 23:15:40 Voltage Offset Correction: v_off_ini = 475.465 uV, v_off_fin = 464.936 uV 23:15:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -199.561 uVs 23:15:40 Integrated Voltage Measurement... 23:15:49 Voltage Offset Correction: v_off_ini = 466.469 uV, v_off_fin = 461.887 uV 23:15:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 180.240 uVs 23:15:51 I2X Average and RMS of Measurements VT = -192.119 +- 3.366 uVs I2X = 17.675 +- 0.310 uTm^2 23:15:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:15:59 Integrated Voltage Measurement... 23:16:08 Voltage Offset Correction: v_off_ini = 453.026 uV, v_off_fin = 443.051 uV 23:16:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0001 mm dXY = 1.0000 mm VT = -283.234 uVs 23:16:08 Integrated Voltage Measurement... 23:16:17 Voltage Offset Correction: v_off_ini = 465.399 uV, v_off_fin = 486.443 uV 23:16:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 300.113 uVs 23:16:17 Integrated Voltage Measurement... 23:16:26 Voltage Offset Correction: v_off_ini = 492.968 uV, v_off_fin = 487.774 uV 23:16:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.516 uVs 23:16:26 Integrated Voltage Measurement... 23:16:35 Voltage Offset Correction: v_off_ini = 482.636 uV, v_off_fin = 470.402 uV 23:16:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.416 uVs 23:16:35 Integrated Voltage Measurement... 23:16:44 Voltage Offset Correction: v_off_ini = 474.912 uV, v_off_fin = 472.061 uV 23:16:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.323 uVs 23:16:44 Integrated Voltage Measurement... 23:16:53 Voltage Offset Correction: v_off_ini = 481.010 uV, v_off_fin = 484.134 uV 23:16:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.996 uVs 23:16:56 I2Y Average and RMS of Measurements VT = -274.100 +- 13.464 uVs I2Y = -25.217 +- 1.239 uTm^2 23:17:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:17:13 Integrated Voltage Measurement... 23:17:22 Voltage Offset Correction: v_off_ini = 519.597 uV, v_off_fin = 515.460 uV 23:17:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -155.176 uVs 23:17:22 Integrated Voltage Measurement... 23:17:31 Voltage Offset Correction: v_off_ini = 524.095 uV, v_off_fin = 509.414 uV 23:17:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 202.983 uVs 23:17:31 Integrated Voltage Measurement... 23:17:40 Voltage Offset Correction: v_off_ini = 523.878 uV, v_off_fin = 516.644 uV 23:17:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -180.364 uVs 23:17:40 Integrated Voltage Measurement... 23:17:49 Voltage Offset Correction: v_off_ini = 499.098 uV, v_off_fin = 497.614 uV 23:17:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.213 uVs 23:17:49 Integrated Voltage Measurement... 23:17:58 Voltage Offset Correction: v_off_ini = 489.839 uV, v_off_fin = 491.849 uV 23:17:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -196.016 uVs 23:17:58 Integrated Voltage Measurement... 23:18:07 Voltage Offset Correction: v_off_ini = 470.101 uV, v_off_fin = 479.700 uV 23:18:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.717 uVs 23:18:11 I1X Average and RMS of Measurements VT = -179.411 +- 3.039 uVs I1X = 35.883 +- 0.608 uTm 23:18:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:18:18 Integrated Voltage Measurement... 23:18:27 Voltage Offset Correction: v_off_ini = 480.650 uV, v_off_fin = 480.395 uV 23:18:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -222.677 uVs 23:18:27 Integrated Voltage Measurement... 23:18:36 Voltage Offset Correction: v_off_ini = 482.693 uV, v_off_fin = 511.577 uV 23:18:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 202.441 uVs 23:18:36 Integrated Voltage Measurement... 23:18:45 Voltage Offset Correction: v_off_ini = 517.978 uV, v_off_fin = 522.154 uV 23:18:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -268.680 uVs 23:18:45 Integrated Voltage Measurement... 23:18:54 Voltage Offset Correction: v_off_ini = 517.126 uV, v_off_fin = 522.870 uV 23:18:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 202.918 uVs 23:18:54 Integrated Voltage Measurement... 23:19:03 Voltage Offset Correction: v_off_ini = 484.938 uV, v_off_fin = 496.987 uV 23:19:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.115 uVs 23:19:03 Integrated Voltage Measurement... 23:19:12 Voltage Offset Correction: v_off_ini = 509.417 uV, v_off_fin = 519.590 uV 23:19:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 229.986 uVs 23:19:16 I1Y Average and RMS of Measurements VT = -224.470 +- 9.497 uVs I1Y = -44.888 +- 1.896 uTm 23:19:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:19:24 Integrated Voltage Measurement... 23:19:33 Voltage Offset Correction: v_off_ini = 515.111 uV, v_off_fin = 519.462 uV 23:19:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -165.526 uVs 23:19:33 Integrated Voltage Measurement... 23:19:42 Voltage Offset Correction: v_off_ini = 525.827 uV, v_off_fin = 536.280 uV 23:19:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 180.189 uVs 23:19:42 Integrated Voltage Measurement... 23:19:51 Voltage Offset Correction: v_off_ini = 538.031 uV, v_off_fin = 527.972 uV 23:19:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -182.996 uVs 23:19:51 Integrated Voltage Measurement... 23:20:00 Voltage Offset Correction: v_off_ini = 534.412 uV, v_off_fin = 519.715 uV 23:20:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 169.252 uVs 23:20:00 Integrated Voltage Measurement... 23:20:09 Voltage Offset Correction: v_off_ini = 532.352 uV, v_off_fin = 501.849 uV 23:20:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -182.611 uVs 23:20:09 Integrated Voltage Measurement... 23:20:18 Voltage Offset Correction: v_off_ini = 507.516 uV, v_off_fin = 496.959 uV 23:20:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.965 uVs 23:20:21 I2X Average and RMS of Measurements VT = -171.923 +- 3.868 uVs I2X = 15.817 +- 0.356 uTm^2 23:20:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:20:28 Integrated Voltage Measurement... 23:20:37 Voltage Offset Correction: v_off_ini = 492.948 uV, v_off_fin = 523.714 uV 23:20:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.883 uVs 23:20:37 Integrated Voltage Measurement... 23:20:46 Voltage Offset Correction: v_off_ini = 503.093 uV, v_off_fin = 503.213 uV 23:20:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.002 uVs 23:20:47 Integrated Voltage Measurement... 23:20:56 Voltage Offset Correction: v_off_ini = 500.584 uV, v_off_fin = 512.223 uV 23:20:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.035 uVs 23:20:56 Integrated Voltage Measurement... 23:21:05 Voltage Offset Correction: v_off_ini = 521.870 uV, v_off_fin = 537.442 uV 23:21:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.271 uVs 23:21:05 Integrated Voltage Measurement... 23:21:14 Voltage Offset Correction: v_off_ini = 529.691 uV, v_off_fin = 521.627 uV 23:21:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.037 uVs 23:21:14 Integrated Voltage Measurement... 23:21:23 Voltage Offset Correction: v_off_ini = 497.750 uV, v_off_fin = 507.068 uV 23:21:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.161 uVs 23:21:25 I2Y Average and RMS of Measurements VT = -259.731 +- 8.185 uVs I2Y = -23.895 +- 0.753 uTm^2 23:21:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:21:42 Integrated Voltage Measurement... 23:21:51 Voltage Offset Correction: v_off_ini = 505.509 uV, v_off_fin = 495.014 uV 23:21:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.776 uVs 23:21:51 Integrated Voltage Measurement... 23:22:00 Voltage Offset Correction: v_off_ini = 511.198 uV, v_off_fin = 497.097 uV 23:22:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 190.166 uVs 23:22:01 Integrated Voltage Measurement... 23:22:09 Voltage Offset Correction: v_off_ini = 475.624 uV, v_off_fin = 495.583 uV 23:22:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -187.431 uVs 23:22:10 Integrated Voltage Measurement... 23:22:18 Voltage Offset Correction: v_off_ini = 485.801 uV, v_off_fin = 492.122 uV 23:22:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 171.354 uVs 23:22:19 Integrated Voltage Measurement... 23:22:27 Voltage Offset Correction: v_off_ini = 490.672 uV, v_off_fin = 497.305 uV 23:22:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -173.265 uVs 23:22:28 Integrated Voltage Measurement... 23:22:37 Voltage Offset Correction: v_off_ini = 482.245 uV, v_off_fin = 482.202 uV 23:22:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 185.496 uVs 23:22:41 I1X Average and RMS of Measurements VT = -181.081 +- 2.397 uVs I1X = 36.216 +- 0.479 uTm 23:22:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:22:48 Integrated Voltage Measurement... 23:22:56 Voltage Offset Correction: v_off_ini = 487.357 uV, v_off_fin = 491.100 uV 23:22:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.645 uVs 23:22:57 Integrated Voltage Measurement... 23:23:05 Voltage Offset Correction: v_off_ini = 498.193 uV, v_off_fin = 502.885 uV 23:23:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 228.947 uVs 23:23:06 Integrated Voltage Measurement... 23:23:14 Voltage Offset Correction: v_off_ini = 498.944 uV, v_off_fin = 493.924 uV 23:23:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -250.970 uVs 23:23:14 Integrated Voltage Measurement... 23:23:23 Voltage Offset Correction: v_off_ini = 505.077 uV, v_off_fin = 476.901 uV 23:23:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.997 uVs 23:23:24 Integrated Voltage Measurement... 23:23:32 Voltage Offset Correction: v_off_ini = 484.410 uV, v_off_fin = 487.878 uV 23:23:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.389 uVs 23:23:33 Integrated Voltage Measurement... 23:23:41 Voltage Offset Correction: v_off_ini = 496.201 uV, v_off_fin = 511.371 uV 23:23:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 231.748 uVs 23:23:46 I1Y Average and RMS of Measurements VT = -225.783 +- 6.117 uVs I1Y = -45.151 +- 1.224 uTm 23:23:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:23:53 Integrated Voltage Measurement... 23:24:02 Voltage Offset Correction: v_off_ini = 485.286 uV, v_off_fin = 495.381 uV 23:24:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -178.038 uVs 23:24:02 Integrated Voltage Measurement... 23:24:11 Voltage Offset Correction: v_off_ini = 506.693 uV, v_off_fin = 510.008 uV 23:24:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 187.378 uVs 23:24:11 Integrated Voltage Measurement... 23:24:20 Voltage Offset Correction: v_off_ini = 472.285 uV, v_off_fin = 473.696 uV 23:24:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.695 uVs 23:24:20 Integrated Voltage Measurement... 23:24:29 Voltage Offset Correction: v_off_ini = 474.154 uV, v_off_fin = 490.466 uV 23:24:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 183.873 uVs 23:24:29 Integrated Voltage Measurement... 23:24:38 Voltage Offset Correction: v_off_ini = 481.014 uV, v_off_fin = 487.489 uV 23:24:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -213.622 uVs 23:24:39 Integrated Voltage Measurement... 23:24:48 Voltage Offset Correction: v_off_ini = 491.080 uV, v_off_fin = 501.225 uV 23:24:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 225.386 uVs 23:24:50 I2X Average and RMS of Measurements VT = -190.665 +- 21.064 uVs I2X = 17.541 +- 1.938 uTm^2 23:24:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:24:58 Integrated Voltage Measurement... 23:25:07 Voltage Offset Correction: v_off_ini = 475.232 uV, v_off_fin = 456.623 uV 23:25:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.574 uVs 23:25:07 Integrated Voltage Measurement... 23:25:16 Voltage Offset Correction: v_off_ini = 452.835 uV, v_off_fin = 489.731 uV 23:25:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.536 uVs 23:25:16 Integrated Voltage Measurement... 23:25:25 Voltage Offset Correction: v_off_ini = 468.389 uV, v_off_fin = 476.153 uV 23:25:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.746 uVs 23:25:25 Integrated Voltage Measurement... 23:25:34 Voltage Offset Correction: v_off_ini = 505.731 uV, v_off_fin = 505.362 uV 23:25:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.557 uVs 23:25:34 Integrated Voltage Measurement... 23:25:43 Voltage Offset Correction: v_off_ini = 512.382 uV, v_off_fin = 456.986 uV 23:25:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.988 uVs 23:25:43 Integrated Voltage Measurement... 23:25:52 Voltage Offset Correction: v_off_ini = 495.379 uV, v_off_fin = 488.186 uV 23:25:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.674 uVs 23:25:54 I2Y Average and RMS of Measurements VT = -260.179 +- 6.102 uVs I2Y = -23.937 +- 0.561 uTm^2 23:26:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:26:12 Integrated Voltage Measurement... 23:26:21 Voltage Offset Correction: v_off_ini = 497.619 uV, v_off_fin = 502.691 uV 23:26:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.472 uVs 23:26:21 Integrated Voltage Measurement... 23:26:30 Voltage Offset Correction: v_off_ini = 505.237 uV, v_off_fin = 523.935 uV 23:26:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 179.920 uVs 23:26:30 Integrated Voltage Measurement... 23:26:39 Voltage Offset Correction: v_off_ini = 499.278 uV, v_off_fin = 501.207 uV 23:26:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.591 uVs 23:26:39 Integrated Voltage Measurement... 23:26:48 Voltage Offset Correction: v_off_ini = 505.727 uV, v_off_fin = 493.541 uV 23:26:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.551 uVs 23:26:48 Integrated Voltage Measurement... 23:26:57 Voltage Offset Correction: v_off_ini = 481.883 uV, v_off_fin = 484.935 uV 23:26:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -169.864 uVs 23:26:57 Integrated Voltage Measurement... 23:27:06 Voltage Offset Correction: v_off_ini = 500.711 uV, v_off_fin = 501.993 uV 23:27:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.474 uVs 23:27:10 I1X Average and RMS of Measurements VT = -167.979 +- 10.766 uVs I1X = 33.596 +- 2.153 uTm 23:27:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:27:17 Integrated Voltage Measurement... 23:27:26 Voltage Offset Correction: v_off_ini = 507.979 uV, v_off_fin = 495.397 uV 23:27:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -230.965 uVs 23:27:26 Integrated Voltage Measurement... 23:27:35 Voltage Offset Correction: v_off_ini = 519.670 uV, v_off_fin = 533.679 uV 23:27:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 250.680 uVs 23:27:35 Integrated Voltage Measurement... 23:27:44 Voltage Offset Correction: v_off_ini = 513.634 uV, v_off_fin = 491.435 uV 23:27:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -224.623 uVs 23:27:44 Integrated Voltage Measurement... 23:27:53 Voltage Offset Correction: v_off_ini = 514.650 uV, v_off_fin = 533.636 uV 23:27:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.175 uVs 23:27:53 Integrated Voltage Measurement... 23:28:02 Voltage Offset Correction: v_off_ini = 490.825 uV, v_off_fin = 489.647 uV 23:28:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -242.455 uVs 23:28:02 Integrated Voltage Measurement... 23:28:11 Voltage Offset Correction: v_off_ini = 499.560 uV, v_off_fin = 528.506 uV 23:28:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.518 uVs 23:28:15 I1Y Average and RMS of Measurements VT = -228.569 +- 10.179 uVs I1Y = -45.711 +- 2.038 uTm 23:28:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:28:23 Integrated Voltage Measurement... 23:28:32 Voltage Offset Correction: v_off_ini = 490.924 uV, v_off_fin = 488.479 uV 23:28:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.531 uVs 23:28:32 Integrated Voltage Measurement... 23:28:41 Voltage Offset Correction: v_off_ini = 511.374 uV, v_off_fin = 495.399 uV 23:28:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 174.150 uVs 23:28:41 Integrated Voltage Measurement... 23:28:50 Voltage Offset Correction: v_off_ini = 462.450 uV, v_off_fin = 474.034 uV 23:28:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -185.852 uVs 23:28:50 Integrated Voltage Measurement... 23:28:59 Voltage Offset Correction: v_off_ini = 475.224 uV, v_off_fin = 498.325 uV 23:28:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 189.974 uVs 23:28:59 Integrated Voltage Measurement... 23:29:08 Voltage Offset Correction: v_off_ini = 481.661 uV, v_off_fin = 461.594 uV 23:29:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -196.487 uVs 23:29:08 Integrated Voltage Measurement... 23:29:17 Voltage Offset Correction: v_off_ini = 471.179 uV, v_off_fin = 467.593 uV 23:29:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 183.471 uVs 23:29:19 I2X Average and RMS of Measurements VT = -183.078 +- 8.342 uVs I2X = 16.843 +- 0.767 uTm^2 23:29:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 23:29:27 Integrated Voltage Measurement... 23:29:36 Voltage Offset Correction: v_off_ini = 458.387 uV, v_off_fin = 482.645 uV 23:29:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.658 uVs 23:29:36 Integrated Voltage Measurement... 23:29:45 Voltage Offset Correction: v_off_ini = 479.935 uV, v_off_fin = 482.501 uV 23:29:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.736 uVs 23:29:45 Integrated Voltage Measurement... 23:29:54 Voltage Offset Correction: v_off_ini = 461.958 uV, v_off_fin = 463.318 uV 23:29:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.895 uVs 23:29:54 Integrated Voltage Measurement... 23:30:03 Voltage Offset Correction: v_off_ini = 463.976 uV, v_off_fin = 467.864 uV 23:30:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.946 uVs 23:30:03 Integrated Voltage Measurement... 23:30:12 Voltage Offset Correction: v_off_ini = 462.795 uV, v_off_fin = 450.445 uV 23:30:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -269.117 uVs 23:30:12 Integrated Voltage Measurement... 23:30:21 Voltage Offset Correction: v_off_ini = 474.793 uV, v_off_fin = 476.565 uV 23:30:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.716 uVs 23:30:24 I2Y Average and RMS of Measurements VT = -268.178 +- 8.484 uVs I2Y = -24.673 +- 0.781 uTm^2 23:30:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm