SLAC Magnetic Measurements Date: 01-22-2025 Time: 10:32:07 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10087 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 4 Measurement Device: On Axis Operator: YL Comment: On Axis 10:32:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:32:18 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:32:19 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:32:21 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:32:22 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:32:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:32:48 Integrated Voltage Measurement... 10:32:57 Voltage Offset Correction: v_off_ini = 435.002 uV, v_off_fin = 435.107 uV 10:32:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -149.032 uVs 10:32:57 Integrated Voltage Measurement... 10:33:06 Voltage Offset Correction: v_off_ini = 438.881 uV, v_off_fin = 437.304 uV 10:33:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.575 uVs 10:33:06 Integrated Voltage Measurement... 10:33:15 Voltage Offset Correction: v_off_ini = 447.202 uV, v_off_fin = 448.354 uV 10:33:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.559 uVs 10:33:15 Integrated Voltage Measurement... 10:33:24 Voltage Offset Correction: v_off_ini = 455.070 uV, v_off_fin = 433.893 uV 10:33:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.788 uVs 10:33:24 Integrated Voltage Measurement... 10:33:33 Voltage Offset Correction: v_off_ini = 418.443 uV, v_off_fin = 405.343 uV 10:33:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.007 uVs 10:33:33 Integrated Voltage Measurement... 10:33:42 Voltage Offset Correction: v_off_ini = 438.284 uV, v_off_fin = 424.970 uV 10:33:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.915 uVs 10:33:46 I1X Average and RMS of Measurements VT = -116.646 +- 5.175 uVs I1X = 23.330 +- 1.035 uTm 10:33:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:33:53 Integrated Voltage Measurement... 10:34:02 Voltage Offset Correction: v_off_ini = 418.369 uV, v_off_fin = 431.700 uV 10:34:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -224.593 uVs 10:34:02 Integrated Voltage Measurement... 10:34:11 Voltage Offset Correction: v_off_ini = 421.371 uV, v_off_fin = 442.878 uV 10:34:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 259.410 uVs 10:34:11 Integrated Voltage Measurement... 10:34:20 Voltage Offset Correction: v_off_ini = 445.781 uV, v_off_fin = 450.791 uV 10:34:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -257.999 uVs 10:34:20 Integrated Voltage Measurement... 10:34:29 Voltage Offset Correction: v_off_ini = 448.920 uV, v_off_fin = 460.022 uV 10:34:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.874 uVs 10:34:29 Integrated Voltage Measurement... 10:34:38 Voltage Offset Correction: v_off_ini = 457.962 uV, v_off_fin = 452.672 uV 10:34:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.290 uVs 10:34:38 Integrated Voltage Measurement... 10:34:47 Voltage Offset Correction: v_off_ini = 441.901 uV, v_off_fin = 453.072 uV 10:34:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.982 uVs 10:34:51 I1Y Average and RMS of Measurements VT = -246.191 +- 4.501 uVs I1Y = -49.237 +- 0.899 uTm 10:34:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:34:59 Integrated Voltage Measurement... 10:35:08 Voltage Offset Correction: v_off_ini = 433.845 uV, v_off_fin = 427.668 uV 10:35:08 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -129.423 uVs 10:35:08 Integrated Voltage Measurement... 10:35:17 Voltage Offset Correction: v_off_ini = 414.432 uV, v_off_fin = 449.831 uV 10:35:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.833 uVs 10:35:17 Integrated Voltage Measurement... 10:35:26 Voltage Offset Correction: v_off_ini = 434.186 uV, v_off_fin = 425.798 uV 10:35:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.270 uVs 10:35:26 Integrated Voltage Measurement... 10:35:35 Voltage Offset Correction: v_off_ini = 424.450 uV, v_off_fin = 450.247 uV 10:35:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.283 uVs 10:35:35 Integrated Voltage Measurement... 10:35:44 Voltage Offset Correction: v_off_ini = 442.642 uV, v_off_fin = 429.455 uV 10:35:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.601 uVs 10:35:44 Integrated Voltage Measurement... 10:35:53 Voltage Offset Correction: v_off_ini = 445.789 uV, v_off_fin = 459.062 uV 10:35:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.897 uVs 10:35:55 I2X Average and RMS of Measurements VT = -137.051 +- 6.578 uVs I2X = 12.609 +- 0.605 uTm^2 10:36:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:36:03 Integrated Voltage Measurement... 10:36:12 Voltage Offset Correction: v_off_ini = 436.811 uV, v_off_fin = 431.362 uV 10:36:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.523 uVs 10:36:12 Integrated Voltage Measurement... 10:36:21 Voltage Offset Correction: v_off_ini = 457.634 uV, v_off_fin = 433.490 uV 10:36:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.254 uVs 10:36:21 Integrated Voltage Measurement... 10:36:30 Voltage Offset Correction: v_off_ini = 433.486 uV, v_off_fin = 460.599 uV 10:36:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.745 uVs 10:36:30 Integrated Voltage Measurement... 10:36:39 Voltage Offset Correction: v_off_ini = 421.454 uV, v_off_fin = 460.739 uV 10:36:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.491 uVs 10:36:39 Integrated Voltage Measurement... 10:36:48 Voltage Offset Correction: v_off_ini = 425.621 uV, v_off_fin = 433.726 uV 10:36:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.265 uVs 10:36:48 Integrated Voltage Measurement... 10:36:57 Voltage Offset Correction: v_off_ini = 418.021 uV, v_off_fin = 427.691 uV 10:36:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.559 uVs 10:37:00 I2Y Average and RMS of Measurements VT = -256.139 +- 17.479 uVs I2Y = -23.565 +- 1.608 uTm^2 10:37:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:37:14 Integrated Voltage Measurement... 10:37:23 Voltage Offset Correction: v_off_ini = 429.302 uV, v_off_fin = 444.242 uV 10:37:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.759 uVs 10:37:23 Integrated Voltage Measurement... 10:37:32 Voltage Offset Correction: v_off_ini = 443.159 uV, v_off_fin = 419.788 uV 10:37:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.783 uVs 10:37:32 Integrated Voltage Measurement... 10:37:41 Voltage Offset Correction: v_off_ini = 430.679 uV, v_off_fin = 426.958 uV 10:37:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.691 uVs 10:37:41 Integrated Voltage Measurement... 10:37:50 Voltage Offset Correction: v_off_ini = 467.112 uV, v_off_fin = 454.112 uV 10:37:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.345 uVs 10:37:50 Integrated Voltage Measurement... 10:37:59 Voltage Offset Correction: v_off_ini = 445.398 uV, v_off_fin = 450.799 uV 10:37:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.737 uVs 10:37:59 Integrated Voltage Measurement... 10:38:08 Voltage Offset Correction: v_off_ini = 435.688 uV, v_off_fin = 478.559 uV 10:38:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.146 uVs 10:38:12 I1X Average and RMS of Measurements VT = -114.910 +- 1.198 uVs I1X = 22.982 +- 0.239 uTm 10:38:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:38:19 Integrated Voltage Measurement... 10:38:28 Voltage Offset Correction: v_off_ini = 414.963 uV, v_off_fin = 425.397 uV 10:38:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -226.011 uVs 10:38:28 Integrated Voltage Measurement... 10:38:37 Voltage Offset Correction: v_off_ini = 449.211 uV, v_off_fin = 456.189 uV 10:38:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.970 uVs 10:38:37 Integrated Voltage Measurement... 10:38:46 Voltage Offset Correction: v_off_ini = 450.982 uV, v_off_fin = 438.912 uV 10:38:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -246.938 uVs 10:38:46 Integrated Voltage Measurement... 10:38:55 Voltage Offset Correction: v_off_ini = 453.394 uV, v_off_fin = 435.307 uV 10:38:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.752 uVs 10:38:55 Integrated Voltage Measurement... 10:39:04 Voltage Offset Correction: v_off_ini = 462.858 uV, v_off_fin = 440.725 uV 10:39:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.834 uVs 10:39:04 Integrated Voltage Measurement... 10:39:13 Voltage Offset Correction: v_off_ini = 472.915 uV, v_off_fin = 470.906 uV 10:39:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 232.868 uVs 10:39:17 I1Y Average and RMS of Measurements VT = -227.729 +- 2.326 uVs I1Y = -45.543 +- 0.463 uTm 10:39:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:39:25 Integrated Voltage Measurement... 10:39:34 Voltage Offset Correction: v_off_ini = 448.788 uV, v_off_fin = 443.055 uV 10:39:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.452 uVs 10:39:34 Integrated Voltage Measurement... 10:39:43 Voltage Offset Correction: v_off_ini = 425.533 uV, v_off_fin = 431.012 uV 10:39:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.404 uVs 10:39:43 Integrated Voltage Measurement... 10:39:52 Voltage Offset Correction: v_off_ini = 443.274 uV, v_off_fin = 447.588 uV 10:39:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.773 uVs 10:39:52 Integrated Voltage Measurement... 10:40:01 Voltage Offset Correction: v_off_ini = 473.340 uV, v_off_fin = 466.930 uV 10:40:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.842 uVs 10:40:01 Integrated Voltage Measurement... 10:40:10 Voltage Offset Correction: v_off_ini = 439.142 uV, v_off_fin = 462.578 uV 10:40:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.640 uVs 10:40:10 Integrated Voltage Measurement... 10:40:19 Voltage Offset Correction: v_off_ini = 476.073 uV, v_off_fin = 441.560 uV 10:40:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.212 uVs 10:40:22 I2X Average and RMS of Measurements VT = -116.554 +- 2.305 uVs I2X = 10.723 +- 0.212 uTm^2 10:40:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:40:29 Integrated Voltage Measurement... 10:40:38 Voltage Offset Correction: v_off_ini = 436.808 uV, v_off_fin = 434.782 uV 10:40:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.291 uVs 10:40:38 Integrated Voltage Measurement... 10:40:47 Voltage Offset Correction: v_off_ini = 410.618 uV, v_off_fin = 440.925 uV 10:40:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.280 uVs 10:40:47 Integrated Voltage Measurement... 10:40:56 Voltage Offset Correction: v_off_ini = 431.274 uV, v_off_fin = 457.453 uV 10:40:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.051 uVs 10:40:56 Integrated Voltage Measurement... 10:41:05 Voltage Offset Correction: v_off_ini = 440.851 uV, v_off_fin = 435.091 uV 10:41:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.335 uVs 10:41:05 Integrated Voltage Measurement... 10:41:14 Voltage Offset Correction: v_off_ini = 463.697 uV, v_off_fin = 468.230 uV 10:41:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.377 uVs 10:41:15 Integrated Voltage Measurement... 10:41:24 Voltage Offset Correction: v_off_ini = 462.832 uV, v_off_fin = 482.870 uV 10:41:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.129 uVs 10:41:26 I2Y Average and RMS of Measurements VT = -245.910 +- 16.362 uVs I2Y = -22.624 +- 1.505 uTm^2 10:41:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:41:40 Integrated Voltage Measurement... 10:41:49 Voltage Offset Correction: v_off_ini = 493.311 uV, v_off_fin = 457.468 uV 10:41:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -111.380 uVs 10:41:49 Integrated Voltage Measurement... 10:41:58 Voltage Offset Correction: v_off_ini = 465.164 uV, v_off_fin = 474.440 uV 10:41:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.507 uVs 10:41:58 Integrated Voltage Measurement... 10:42:07 Voltage Offset Correction: v_off_ini = 474.341 uV, v_off_fin = 455.974 uV 10:42:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.584 uVs 10:42:07 Integrated Voltage Measurement... 10:42:16 Voltage Offset Correction: v_off_ini = 451.772 uV, v_off_fin = 443.769 uV 10:42:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.063 uVs 10:42:16 Integrated Voltage Measurement... 10:42:25 Voltage Offset Correction: v_off_ini = 446.293 uV, v_off_fin = 483.001 uV 10:42:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.847 uVs 10:42:25 Integrated Voltage Measurement... 10:42:34 Voltage Offset Correction: v_off_ini = 475.561 uV, v_off_fin = 478.507 uV 10:42:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.089 uVs 10:42:38 I1X Average and RMS of Measurements VT = -101.578 +- 19.670 uVs I1X = 20.317 +- 3.933 uTm 10:42:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:42:45 Integrated Voltage Measurement... 10:42:54 Voltage Offset Correction: v_off_ini = 461.460 uV, v_off_fin = 443.106 uV 10:42:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -215.065 uVs 10:42:54 Integrated Voltage Measurement... 10:43:03 Voltage Offset Correction: v_off_ini = 407.751 uV, v_off_fin = 431.794 uV 10:43:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.077 uVs 10:43:03 Integrated Voltage Measurement... 10:43:12 Voltage Offset Correction: v_off_ini = 445.318 uV, v_off_fin = 456.485 uV 10:43:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.971 uVs 10:43:12 Integrated Voltage Measurement... 10:43:21 Voltage Offset Correction: v_off_ini = 416.546 uV, v_off_fin = 483.282 uV 10:43:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.917 uVs 10:43:21 Integrated Voltage Measurement... 10:43:30 Voltage Offset Correction: v_off_ini = 482.447 uV, v_off_fin = 461.612 uV 10:43:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.184 uVs 10:43:30 Integrated Voltage Measurement... 10:43:39 Voltage Offset Correction: v_off_ini = 446.266 uV, v_off_fin = 438.449 uV 10:43:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.890 uVs 10:43:43 I1Y Average and RMS of Measurements VT = -235.851 +- 7.746 uVs I1Y = -47.171 +- 1.552 uTm 10:43:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:43:51 Integrated Voltage Measurement... 10:44:00 Voltage Offset Correction: v_off_ini = 460.973 uV, v_off_fin = 435.505 uV 10:44:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.776 uVs 10:44:00 Integrated Voltage Measurement... 10:44:09 Voltage Offset Correction: v_off_ini = 480.231 uV, v_off_fin = 457.263 uV 10:44:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.038 uVs 10:44:09 Integrated Voltage Measurement... 10:44:18 Voltage Offset Correction: v_off_ini = 454.739 uV, v_off_fin = 471.074 uV 10:44:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.392 uVs 10:44:18 Integrated Voltage Measurement... 10:44:27 Voltage Offset Correction: v_off_ini = 460.002 uV, v_off_fin = 465.583 uV 10:44:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.968 uVs 10:44:27 Integrated Voltage Measurement... 10:44:36 Voltage Offset Correction: v_off_ini = 446.810 uV, v_off_fin = 441.146 uV 10:44:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.810 uVs 10:44:36 Integrated Voltage Measurement... 10:44:45 Voltage Offset Correction: v_off_ini = 456.767 uV, v_off_fin = 470.184 uV 10:44:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.908 uVs 10:44:47 I2X Average and RMS of Measurements VT = -104.649 +- 11.159 uVs I2X = 9.628 +- 1.027 uTm^2 10:44:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:44:55 Integrated Voltage Measurement... 10:45:04 Voltage Offset Correction: v_off_ini = 467.709 uV, v_off_fin = 419.081 uV 10:45:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -258.026 uVs 10:45:04 Integrated Voltage Measurement... 10:45:13 Voltage Offset Correction: v_off_ini = 464.515 uV, v_off_fin = 464.077 uV 10:45:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.746 uVs 10:45:13 Integrated Voltage Measurement... 10:45:22 Voltage Offset Correction: v_off_ini = 427.249 uV, v_off_fin = 436.151 uV 10:45:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.954 uVs 10:45:22 Integrated Voltage Measurement... 10:45:31 Voltage Offset Correction: v_off_ini = 467.858 uV, v_off_fin = 472.149 uV 10:45:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.525 uVs 10:45:31 Integrated Voltage Measurement... 10:45:40 Voltage Offset Correction: v_off_ini = 465.378 uV, v_off_fin = 468.101 uV 10:45:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.864 uVs 10:45:40 Integrated Voltage Measurement... 10:45:49 Voltage Offset Correction: v_off_ini = 441.376 uV, v_off_fin = 458.599 uV 10:45:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.522 uVs 10:45:52 I2Y Average and RMS of Measurements VT = -246.606 +- 9.211 uVs I2Y = -22.688 +- 0.847 uTm^2 10:46:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:46:06 Integrated Voltage Measurement... 10:46:15 Voltage Offset Correction: v_off_ini = 452.369 uV, v_off_fin = 428.392 uV 10:46:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -105.901 uVs 10:46:15 Integrated Voltage Measurement... 10:46:24 Voltage Offset Correction: v_off_ini = 453.435 uV, v_off_fin = 466.987 uV 10:46:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.126 uVs 10:46:24 Integrated Voltage Measurement... 10:46:33 Voltage Offset Correction: v_off_ini = 464.612 uV, v_off_fin = 484.166 uV 10:46:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.863 uVs 10:46:33 Integrated Voltage Measurement... 10:46:42 Voltage Offset Correction: v_off_ini = 492.719 uV, v_off_fin = 471.946 uV 10:46:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.438 uVs 10:46:42 Integrated Voltage Measurement... 10:46:51 Voltage Offset Correction: v_off_ini = 462.433 uV, v_off_fin = 460.802 uV 10:46:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.224 uVs 10:46:51 Integrated Voltage Measurement... 10:47:00 Voltage Offset Correction: v_off_ini = 434.141 uV, v_off_fin = 438.335 uV 10:47:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.046 uVs 10:47:04 I1X Average and RMS of Measurements VT = -76.933 +- 13.925 uVs I1X = 15.387 +- 2.786 uTm 10:47:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:47:11 Integrated Voltage Measurement... 10:47:20 Voltage Offset Correction: v_off_ini = 443.393 uV, v_off_fin = 495.921 uV 10:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -239.756 uVs 10:47:20 Integrated Voltage Measurement... 10:47:29 Voltage Offset Correction: v_off_ini = 485.004 uV, v_off_fin = 492.404 uV 10:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.206 uVs 10:47:29 Integrated Voltage Measurement... 10:47:38 Voltage Offset Correction: v_off_ini = 468.795 uV, v_off_fin = 461.587 uV 10:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.361 uVs 10:47:38 Integrated Voltage Measurement... 10:47:47 Voltage Offset Correction: v_off_ini = 462.627 uV, v_off_fin = 438.618 uV 10:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.344 uVs 10:47:47 Integrated Voltage Measurement... 10:47:56 Voltage Offset Correction: v_off_ini = 437.777 uV, v_off_fin = 465.990 uV 10:47:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.135 uVs 10:47:56 Integrated Voltage Measurement... 10:48:05 Voltage Offset Correction: v_off_ini = 477.001 uV, v_off_fin = 488.776 uV 10:48:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.739 uVs 10:48:09 I1Y Average and RMS of Measurements VT = -241.424 +- 7.311 uVs I1Y = -48.286 +- 1.461 uTm 10:48:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:48:17 Integrated Voltage Measurement... 10:48:26 Voltage Offset Correction: v_off_ini = 451.133 uV, v_off_fin = 496.666 uV 10:48:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -23.853 uVs 10:48:26 Integrated Voltage Measurement... 10:48:35 Voltage Offset Correction: v_off_ini = 492.259 uV, v_off_fin = 485.675 uV 10:48:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.587 uVs 10:48:35 Integrated Voltage Measurement... 10:48:44 Voltage Offset Correction: v_off_ini = 489.000 uV, v_off_fin = 488.099 uV 10:48:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.512 uVs 10:48:44 Integrated Voltage Measurement... 10:48:53 Voltage Offset Correction: v_off_ini = 509.896 uV, v_off_fin = 505.297 uV 10:48:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.353 uVs 10:48:53 Integrated Voltage Measurement... 10:49:02 Voltage Offset Correction: v_off_ini = 459.373 uV, v_off_fin = 468.889 uV 10:49:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.059 uVs 10:49:02 Integrated Voltage Measurement... 10:49:11 Voltage Offset Correction: v_off_ini = 491.030 uV, v_off_fin = 477.455 uV 10:49:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.192 uVs 10:49:14 I2X Average and RMS of Measurements VT = -74.426 +- 23.466 uVs I2X = 6.847 +- 2.159 uTm^2 10:49:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:49:21 Integrated Voltage Measurement... 10:49:30 Voltage Offset Correction: v_off_ini = 479.508 uV, v_off_fin = 471.594 uV 10:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.240 uVs 10:49:30 Integrated Voltage Measurement... 10:49:39 Voltage Offset Correction: v_off_ini = 465.367 uV, v_off_fin = 455.406 uV 10:49:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.487 uVs 10:49:39 Integrated Voltage Measurement... 10:49:48 Voltage Offset Correction: v_off_ini = 437.466 uV, v_off_fin = 460.431 uV 10:49:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.720 uVs 10:49:48 Integrated Voltage Measurement... 10:49:57 Voltage Offset Correction: v_off_ini = 455.857 uV, v_off_fin = 481.523 uV 10:49:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.720 uVs 10:49:58 Integrated Voltage Measurement... 10:50:07 Voltage Offset Correction: v_off_ini = 480.498 uV, v_off_fin = 483.894 uV 10:50:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.275 uVs 10:50:07 Integrated Voltage Measurement... 10:50:16 Voltage Offset Correction: v_off_ini = 468.339 uV, v_off_fin = 479.196 uV 10:50:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.563 uVs 10:50:18 I2Y Average and RMS of Measurements VT = -253.334 +- 21.277 uVs I2Y = -23.307 +- 1.957 uTm^2 10:50:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:50:32 Integrated Voltage Measurement... 10:50:41 Voltage Offset Correction: v_off_ini = 448.659 uV, v_off_fin = 458.637 uV 10:50:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -55.390 uVs 10:50:41 Integrated Voltage Measurement... 10:50:50 Voltage Offset Correction: v_off_ini = 517.524 uV, v_off_fin = 486.856 uV 10:50:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.130 uVs 10:50:50 Integrated Voltage Measurement... 10:50:59 Voltage Offset Correction: v_off_ini = 460.737 uV, v_off_fin = 477.220 uV 10:50:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.890 uVs 10:50:59 Integrated Voltage Measurement... 10:51:08 Voltage Offset Correction: v_off_ini = 463.788 uV, v_off_fin = 441.755 uV 10:51:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.852 uVs 10:51:08 Integrated Voltage Measurement... 10:51:17 Voltage Offset Correction: v_off_ini = 448.104 uV, v_off_fin = 453.740 uV 10:51:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.738 uVs 10:51:17 Integrated Voltage Measurement... 10:51:26 Voltage Offset Correction: v_off_ini = 456.360 uV, v_off_fin = 442.420 uV 10:51:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.555 uVs 10:51:30 I1X Average and RMS of Measurements VT = -78.926 +- 16.838 uVs I1X = 15.785 +- 3.367 uTm 10:51:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:51:37 Integrated Voltage Measurement... 10:51:46 Voltage Offset Correction: v_off_ini = 444.696 uV, v_off_fin = 463.612 uV 10:51:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -221.854 uVs 10:51:46 Integrated Voltage Measurement... 10:51:55 Voltage Offset Correction: v_off_ini = 455.719 uV, v_off_fin = 459.372 uV 10:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.263 uVs 10:51:55 Integrated Voltage Measurement... 10:52:04 Voltage Offset Correction: v_off_ini = 428.187 uV, v_off_fin = 443.834 uV 10:52:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.955 uVs 10:52:04 Integrated Voltage Measurement... 10:52:13 Voltage Offset Correction: v_off_ini = 447.625 uV, v_off_fin = 469.014 uV 10:52:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.051 uVs 10:52:13 Integrated Voltage Measurement... 10:52:22 Voltage Offset Correction: v_off_ini = 479.420 uV, v_off_fin = 458.397 uV 10:52:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.241 uVs 10:52:22 Integrated Voltage Measurement... 10:52:31 Voltage Offset Correction: v_off_ini = 463.809 uV, v_off_fin = 413.317 uV 10:52:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.972 uVs 10:52:35 I1Y Average and RMS of Measurements VT = -228.223 +- 2.293 uVs I1Y = -45.645 +- 0.459 uTm 10:52:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:52:43 Integrated Voltage Measurement... 10:52:52 Voltage Offset Correction: v_off_ini = 464.954 uV, v_off_fin = 478.947 uV 10:52:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.065 uVs 10:52:52 Integrated Voltage Measurement... 10:53:01 Voltage Offset Correction: v_off_ini = 444.778 uV, v_off_fin = 481.971 uV 10:53:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.116 uVs 10:53:01 Integrated Voltage Measurement... 10:53:10 Voltage Offset Correction: v_off_ini = 476.322 uV, v_off_fin = 485.607 uV 10:53:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.916 uVs 10:53:10 Integrated Voltage Measurement... 10:53:19 Voltage Offset Correction: v_off_ini = 488.752 uV, v_off_fin = 481.938 uV 10:53:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.774 uVs 10:53:19 Integrated Voltage Measurement... 10:53:28 Voltage Offset Correction: v_off_ini = 515.769 uV, v_off_fin = 517.918 uV 10:53:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.237 uVs 10:53:28 Integrated Voltage Measurement... 10:53:37 Voltage Offset Correction: v_off_ini = 487.125 uV, v_off_fin = 496.471 uV 10:53:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.993 uVs 10:53:40 I2X Average and RMS of Measurements VT = -77.184 +- 8.923 uVs I2X = 7.101 +- 0.821 uTm^2 10:53:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:53:47 Integrated Voltage Measurement... 10:53:56 Voltage Offset Correction: v_off_ini = 520.088 uV, v_off_fin = 525.725 uV 10:53:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -248.992 uVs 10:53:57 Integrated Voltage Measurement... 10:54:06 Voltage Offset Correction: v_off_ini = 499.345 uV, v_off_fin = 493.844 uV 10:54:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.622 uVs 10:54:06 Integrated Voltage Measurement... 10:54:15 Voltage Offset Correction: v_off_ini = 493.355 uV, v_off_fin = 494.084 uV 10:54:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.812 uVs 10:54:15 Integrated Voltage Measurement... 10:54:24 Voltage Offset Correction: v_off_ini = 506.548 uV, v_off_fin = 565.786 uV 10:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.696 uVs 10:54:24 Integrated Voltage Measurement... 10:54:33 Voltage Offset Correction: v_off_ini = 482.965 uV, v_off_fin = 513.195 uV 10:54:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.865 uVs 10:54:33 Integrated Voltage Measurement... 10:54:42 Voltage Offset Correction: v_off_ini = 498.427 uV, v_off_fin = 480.547 uV 10:54:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.069 uVs 10:54:44 I2Y Average and RMS of Measurements VT = -257.176 +- 9.454 uVs I2Y = -23.661 +- 0.869 uTm^2 10:54:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:54:58 Integrated Voltage Measurement... 10:55:07 Voltage Offset Correction: v_off_ini = 493.875 uV, v_off_fin = 480.366 uV 10:55:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.743 uVs 10:55:07 Integrated Voltage Measurement... 10:55:16 Voltage Offset Correction: v_off_ini = 521.645 uV, v_off_fin = 497.559 uV 10:55:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.785 uVs 10:55:16 Integrated Voltage Measurement... 10:55:25 Voltage Offset Correction: v_off_ini = 478.679 uV, v_off_fin = 471.245 uV 10:55:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.395 uVs 10:55:25 Integrated Voltage Measurement... 10:55:34 Voltage Offset Correction: v_off_ini = 476.250 uV, v_off_fin = 481.542 uV 10:55:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.408 uVs 10:55:34 Integrated Voltage Measurement... 10:55:43 Voltage Offset Correction: v_off_ini = 483.450 uV, v_off_fin = 493.873 uV 10:55:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.944 uVs 10:55:43 Integrated Voltage Measurement... 10:55:52 Voltage Offset Correction: v_off_ini = 508.298 uV, v_off_fin = 483.081 uV 10:55:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.792 uVs 10:55:56 I1X Average and RMS of Measurements VT = -60.845 +- 9.215 uVs I1X = 12.169 +- 1.844 uTm 10:55:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:56:03 Integrated Voltage Measurement... 10:56:12 Voltage Offset Correction: v_off_ini = 527.365 uV, v_off_fin = 508.143 uV 10:56:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -254.927 uVs 10:56:12 Integrated Voltage Measurement... 10:56:21 Voltage Offset Correction: v_off_ini = 536.673 uV, v_off_fin = 517.794 uV 10:56:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.271 uVs 10:56:21 Integrated Voltage Measurement... 10:56:30 Voltage Offset Correction: v_off_ini = 495.602 uV, v_off_fin = 555.887 uV 10:56:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.578 uVs 10:56:30 Integrated Voltage Measurement... 10:56:39 Voltage Offset Correction: v_off_ini = 528.178 uV, v_off_fin = 541.896 uV 10:56:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.496 uVs 10:56:39 Integrated Voltage Measurement... 10:56:48 Voltage Offset Correction: v_off_ini = 534.354 uV, v_off_fin = 508.784 uV 10:56:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -237.525 uVs 10:56:48 Integrated Voltage Measurement... 10:56:57 Voltage Offset Correction: v_off_ini = 520.843 uV, v_off_fin = 565.095 uV 10:56:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.372 uVs 10:57:01 I1Y Average and RMS of Measurements VT = -225.361 +- 10.699 uVs I1Y = -45.070 +- 2.142 uTm 10:57:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:57:09 Integrated Voltage Measurement... 10:57:18 Voltage Offset Correction: v_off_ini = 496.769 uV, v_off_fin = 504.369 uV 10:57:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.674 uVs 10:57:18 Integrated Voltage Measurement... 10:57:27 Voltage Offset Correction: v_off_ini = 571.061 uV, v_off_fin = 552.940 uV 10:57:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.888 uVs 10:57:27 Integrated Voltage Measurement... 10:57:36 Voltage Offset Correction: v_off_ini = 512.071 uV, v_off_fin = 543.301 uV 10:57:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.696 uVs 10:57:36 Integrated Voltage Measurement... 10:57:45 Voltage Offset Correction: v_off_ini = 555.098 uV, v_off_fin = 515.408 uV 10:57:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.231 uVs 10:57:45 Integrated Voltage Measurement... 10:57:54 Voltage Offset Correction: v_off_ini = 537.331 uV, v_off_fin = 494.238 uV 10:57:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.492 uVs 10:57:54 Integrated Voltage Measurement... 10:58:03 Voltage Offset Correction: v_off_ini = 545.015 uV, v_off_fin = 541.499 uV 10:58:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.659 uVs 10:58:06 I2X Average and RMS of Measurements VT = -63.273 +- 4.898 uVs I2X = 5.821 +- 0.451 uTm^2 10:58:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:58:14 Integrated Voltage Measurement... 10:58:23 Voltage Offset Correction: v_off_ini = 531.392 uV, v_off_fin = 556.214 uV 10:58:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.684 uVs 10:58:23 Integrated Voltage Measurement... 10:58:32 Voltage Offset Correction: v_off_ini = 539.413 uV, v_off_fin = 572.005 uV 10:58:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.936 uVs 10:58:32 Integrated Voltage Measurement... 10:58:41 Voltage Offset Correction: v_off_ini = 595.884 uV, v_off_fin = 542.263 uV 10:58:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.007 uVs 10:58:41 Integrated Voltage Measurement... 10:58:50 Voltage Offset Correction: v_off_ini = 562.268 uV, v_off_fin = 575.716 uV 10:58:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.821 uVs 10:58:50 Integrated Voltage Measurement... 10:58:59 Voltage Offset Correction: v_off_ini = 554.600 uV, v_off_fin = 545.653 uV 10:58:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.824 uVs 10:58:59 Integrated Voltage Measurement... 10:59:08 Voltage Offset Correction: v_off_ini = 555.133 uV, v_off_fin = 585.928 uV 10:59:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.927 uVs 10:59:10 I2Y Average and RMS of Measurements VT = -247.866 +- 7.092 uVs I2Y = -22.804 +- 0.652 uTm^2 10:59:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:59:24 Integrated Voltage Measurement... 10:59:33 Voltage Offset Correction: v_off_ini = 543.704 uV, v_off_fin = 592.667 uV 10:59:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -46.153 uVs 10:59:33 Integrated Voltage Measurement... 10:59:42 Voltage Offset Correction: v_off_ini = 545.007 uV, v_off_fin = 604.690 uV 10:59:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.509 uVs 10:59:42 Integrated Voltage Measurement... 10:59:51 Voltage Offset Correction: v_off_ini = 561.028 uV, v_off_fin = 559.313 uV 10:59:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.133 uVs 10:59:51 Integrated Voltage Measurement... 11:00:00 Voltage Offset Correction: v_off_ini = 578.143 uV, v_off_fin = 561.757 uV 11:00:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 7.327 uVs 11:00:00 Integrated Voltage Measurement... 11:00:09 Voltage Offset Correction: v_off_ini = 567.524 uV, v_off_fin = 556.815 uV 11:00:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.699 uVs 11:00:09 Integrated Voltage Measurement... 11:00:18 Voltage Offset Correction: v_off_ini = 601.591 uV, v_off_fin = 584.995 uV 11:00:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.089 uVs 11:00:23 I1X Average and RMS of Measurements VT = -52.652 +- 3.225 uVs I1X = 10.530 +- 0.645 uTm 11:00:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:00:29 Integrated Voltage Measurement... 11:00:38 Voltage Offset Correction: v_off_ini = 571.781 uV, v_off_fin = 530.215 uV 11:00:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -231.675 uVs 11:00:38 Integrated Voltage Measurement... 11:00:47 Voltage Offset Correction: v_off_ini = 586.791 uV, v_off_fin = 621.398 uV 11:00:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.501 uVs 11:00:47 Integrated Voltage Measurement... 11:00:56 Voltage Offset Correction: v_off_ini = 563.984 uV, v_off_fin = 545.042 uV 11:00:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -270.167 uVs 11:00:56 Integrated Voltage Measurement... 11:01:05 Voltage Offset Correction: v_off_ini = 548.849 uV, v_off_fin = 552.507 uV 11:01:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.247 uVs 11:01:05 Integrated Voltage Measurement... 11:01:14 Voltage Offset Correction: v_off_ini = 526.096 uV, v_off_fin = 514.475 uV 11:01:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -224.894 uVs 11:01:14 Integrated Voltage Measurement... 11:01:23 Voltage Offset Correction: v_off_ini = 519.224 uV, v_off_fin = 544.063 uV 11:01:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.535 uVs 11:01:28 I1Y Average and RMS of Measurements VT = -237.503 +- 7.676 uVs I1Y = -47.499 +- 1.532 uTm 11:01:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:01:35 Integrated Voltage Measurement... 11:01:44 Voltage Offset Correction: v_off_ini = 536.350 uV, v_off_fin = 506.561 uV 11:01:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.404 uVs 11:01:44 Integrated Voltage Measurement... 11:01:53 Voltage Offset Correction: v_off_ini = 535.677 uV, v_off_fin = 559.712 uV 11:01:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.788 uVs 11:01:53 Integrated Voltage Measurement... 11:02:02 Voltage Offset Correction: v_off_ini = 535.524 uV, v_off_fin = 533.475 uV 11:02:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.066 uVs 11:02:03 Integrated Voltage Measurement... 11:02:11 Voltage Offset Correction: v_off_ini = 575.848 uV, v_off_fin = 529.216 uV 11:02:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.047 uVs 11:02:12 Integrated Voltage Measurement... 11:02:21 Voltage Offset Correction: v_off_ini = 531.254 uV, v_off_fin = 528.677 uV 11:02:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.245 uVs 11:02:21 Integrated Voltage Measurement... 11:02:30 Voltage Offset Correction: v_off_ini = 506.759 uV, v_off_fin = 536.329 uV 11:02:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.793 uVs 11:02:32 I2X Average and RMS of Measurements VT = -73.890 +- 2.263 uVs I2X = 6.798 +- 0.208 uTm^2 11:02:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:02:40 Integrated Voltage Measurement... 11:02:49 Voltage Offset Correction: v_off_ini = 540.355 uV, v_off_fin = 519.973 uV 11:02:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.917 uVs 11:02:49 Integrated Voltage Measurement... 11:02:58 Voltage Offset Correction: v_off_ini = 541.551 uV, v_off_fin = 537.768 uV 11:02:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.445 uVs 11:02:58 Integrated Voltage Measurement... 11:03:07 Voltage Offset Correction: v_off_ini = 568.860 uV, v_off_fin = 557.347 uV 11:03:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.820 uVs 11:03:07 Integrated Voltage Measurement... 11:03:16 Voltage Offset Correction: v_off_ini = 542.611 uV, v_off_fin = 522.382 uV 11:03:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.738 uVs 11:03:16 Integrated Voltage Measurement... 11:03:25 Voltage Offset Correction: v_off_ini = 536.348 uV, v_off_fin = 545.414 uV 11:03:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.311 uVs 11:03:25 Integrated Voltage Measurement... 11:03:34 Voltage Offset Correction: v_off_ini = 537.341 uV, v_off_fin = 549.045 uV 11:03:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.319 uVs 11:03:36 I2Y Average and RMS of Measurements VT = -231.258 +- 8.310 uVs I2Y = -21.276 +- 0.765 uTm^2 11:03:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:03:50 Integrated Voltage Measurement... 11:03:59 Voltage Offset Correction: v_off_ini = 597.842 uV, v_off_fin = 574.049 uV 11:03:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.212 uVs 11:03:59 Integrated Voltage Measurement... 11:04:08 Voltage Offset Correction: v_off_ini = 567.462 uV, v_off_fin = 545.354 uV 11:04:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.885 uVs 11:04:08 Integrated Voltage Measurement... 11:04:17 Voltage Offset Correction: v_off_ini = 550.360 uV, v_off_fin = 569.906 uV 11:04:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.057 uVs 11:04:17 Integrated Voltage Measurement... 11:04:26 Voltage Offset Correction: v_off_ini = 571.270 uV, v_off_fin = 577.022 uV 11:04:26 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.641 uVs 11:04:27 Integrated Voltage Measurement... 11:04:35 Voltage Offset Correction: v_off_ini = 559.012 uV, v_off_fin = 551.499 uV 11:04:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.460 uVs 11:04:36 Integrated Voltage Measurement... 11:04:44 Voltage Offset Correction: v_off_ini = 534.540 uV, v_off_fin = 585.829 uV 11:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.706 uVs 11:04:49 I1X Average and RMS of Measurements VT = -53.160 +- 2.255 uVs I1X = 10.632 +- 0.451 uTm 11:04:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:04:56 Integrated Voltage Measurement... 11:05:04 Voltage Offset Correction: v_off_ini = 569.982 uV, v_off_fin = 561.097 uV 11:05:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -246.741 uVs 11:05:05 Integrated Voltage Measurement... 11:05:13 Voltage Offset Correction: v_off_ini = 577.287 uV, v_off_fin = 580.691 uV 11:05:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 224.709 uVs 11:05:14 Integrated Voltage Measurement... 11:05:22 Voltage Offset Correction: v_off_ini = 566.527 uV, v_off_fin = 577.185 uV 11:05:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.524 uVs 11:05:23 Integrated Voltage Measurement... 11:05:32 Voltage Offset Correction: v_off_ini = 605.345 uV, v_off_fin = 577.851 uV 11:05:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.177 uVs 11:05:32 Integrated Voltage Measurement... 11:05:41 Voltage Offset Correction: v_off_ini = 580.689 uV, v_off_fin = 574.837 uV 11:05:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.893 uVs 11:05:41 Integrated Voltage Measurement... 11:05:50 Voltage Offset Correction: v_off_ini = 576.461 uV, v_off_fin = 567.030 uV 11:05:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.220 uVs 11:05:54 I1Y Average and RMS of Measurements VT = -224.211 +- 10.491 uVs I1Y = -44.841 +- 2.099 uTm 11:05:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:06:02 Integrated Voltage Measurement... 11:06:10 Voltage Offset Correction: v_off_ini = 559.528 uV, v_off_fin = 545.909 uV 11:06:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.979 uVs 11:06:11 Integrated Voltage Measurement... 11:06:20 Voltage Offset Correction: v_off_ini = 565.544 uV, v_off_fin = 578.967 uV 11:06:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 59.287 uVs 11:06:20 Integrated Voltage Measurement... 11:06:29 Voltage Offset Correction: v_off_ini = 582.444 uV, v_off_fin = 556.254 uV 11:06:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.376 uVs 11:06:29 Integrated Voltage Measurement... 11:06:38 Voltage Offset Correction: v_off_ini = 586.436 uV, v_off_fin = 590.069 uV 11:06:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.555 uVs 11:06:38 Integrated Voltage Measurement... 11:06:47 Voltage Offset Correction: v_off_ini = 576.711 uV, v_off_fin = 547.547 uV 11:06:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.439 uVs 11:06:47 Integrated Voltage Measurement... 11:06:56 Voltage Offset Correction: v_off_ini = 588.271 uV, v_off_fin = 600.876 uV 11:06:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.439 uVs 11:06:58 I2X Average and RMS of Measurements VT = -60.846 +- 4.186 uVs I2X = 5.598 +- 0.385 uTm^2 11:07:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:07:06 Integrated Voltage Measurement... 11:07:15 Voltage Offset Correction: v_off_ini = 594.706 uV, v_off_fin = 584.164 uV 11:07:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.731 uVs 11:07:15 Integrated Voltage Measurement... 11:07:24 Voltage Offset Correction: v_off_ini = 613.759 uV, v_off_fin = 599.406 uV 11:07:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.327 uVs 11:07:24 Integrated Voltage Measurement... 11:07:33 Voltage Offset Correction: v_off_ini = 621.069 uV, v_off_fin = 621.852 uV 11:07:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.929 uVs 11:07:33 Integrated Voltage Measurement... 11:07:42 Voltage Offset Correction: v_off_ini = 655.474 uV, v_off_fin = 652.338 uV 11:07:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.149 uVs 11:07:42 Integrated Voltage Measurement... 11:07:51 Voltage Offset Correction: v_off_ini = 616.917 uV, v_off_fin = 603.800 uV 11:07:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.770 uVs 11:07:51 Integrated Voltage Measurement... 11:08:00 Voltage Offset Correction: v_off_ini = 635.868 uV, v_off_fin = 641.321 uV 11:08:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.421 uVs 11:08:03 I2Y Average and RMS of Measurements VT = -245.555 +- 14.585 uVs I2Y = -22.591 +- 1.342 uTm^2 11:08:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:08:17 Integrated Voltage Measurement... 11:08:26 Voltage Offset Correction: v_off_ini = 626.135 uV, v_off_fin = 640.576 uV 11:08:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -36.284 uVs 11:08:26 Integrated Voltage Measurement... 11:08:35 Voltage Offset Correction: v_off_ini = 616.915 uV, v_off_fin = 641.037 uV 11:08:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.409 uVs 11:08:35 Integrated Voltage Measurement... 11:08:44 Voltage Offset Correction: v_off_ini = 615.818 uV, v_off_fin = 639.690 uV 11:08:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.355 uVs 11:08:44 Integrated Voltage Measurement... 11:08:53 Voltage Offset Correction: v_off_ini = 600.200 uV, v_off_fin = 623.378 uV 11:08:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 14.506 uVs 11:08:53 Integrated Voltage Measurement... 11:09:02 Voltage Offset Correction: v_off_ini = 613.538 uV, v_off_fin = 625.774 uV 11:09:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.641 uVs 11:09:02 Integrated Voltage Measurement... 11:09:11 Voltage Offset Correction: v_off_ini = 614.950 uV, v_off_fin = 590.342 uV 11:09:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 15.743 uVs 11:09:15 I1X Average and RMS of Measurements VT = -38.490 +- 9.498 uVs I1X = 7.698 +- 1.900 uTm 11:09:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:09:22 Integrated Voltage Measurement... 11:09:31 Voltage Offset Correction: v_off_ini = 640.732 uV, v_off_fin = 641.423 uV 11:09:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -209.035 uVs 11:09:31 Integrated Voltage Measurement... 11:09:40 Voltage Offset Correction: v_off_ini = 641.478 uV, v_off_fin = 628.915 uV 11:09:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.446 uVs 11:09:40 Integrated Voltage Measurement... 11:09:49 Voltage Offset Correction: v_off_ini = 626.002 uV, v_off_fin = 601.962 uV 11:09:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -234.150 uVs 11:09:49 Integrated Voltage Measurement... 11:09:58 Voltage Offset Correction: v_off_ini = 596.118 uV, v_off_fin = 633.834 uV 11:09:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 268.690 uVs 11:09:58 Integrated Voltage Measurement... 11:10:07 Voltage Offset Correction: v_off_ini = 622.819 uV, v_off_fin = 609.327 uV 11:10:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.487 uVs 11:10:07 Integrated Voltage Measurement... 11:10:16 Voltage Offset Correction: v_off_ini = 603.983 uV, v_off_fin = 621.463 uV 11:10:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.132 uVs 11:10:20 I1Y Average and RMS of Measurements VT = -233.323 +- 14.770 uVs I1Y = -46.661 +- 2.952 uTm 11:10:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:10:28 Integrated Voltage Measurement... 11:10:37 Voltage Offset Correction: v_off_ini = 632.966 uV, v_off_fin = 600.480 uV 11:10:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.610 uVs 11:10:37 Integrated Voltage Measurement... 11:10:46 Voltage Offset Correction: v_off_ini = 593.907 uV, v_off_fin = 609.741 uV 11:10:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.100 uVs 11:10:46 Integrated Voltage Measurement... 11:10:55 Voltage Offset Correction: v_off_ini = 632.214 uV, v_off_fin = 626.852 uV 11:10:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.819 uVs 11:10:55 Integrated Voltage Measurement... 11:11:04 Voltage Offset Correction: v_off_ini = 677.225 uV, v_off_fin = 661.050 uV 11:11:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.176 uVs 11:11:04 Integrated Voltage Measurement... 11:11:13 Voltage Offset Correction: v_off_ini = 599.135 uV, v_off_fin = 603.242 uV 11:11:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.665 uVs 11:11:13 Integrated Voltage Measurement... 11:11:22 Voltage Offset Correction: v_off_ini = 627.283 uV, v_off_fin = 632.205 uV 11:11:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.390 uVs 11:11:25 I2X Average and RMS of Measurements VT = -56.793 +- 7.604 uVs I2X = 5.225 +- 0.700 uTm^2 11:11:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:11:32 Integrated Voltage Measurement... 11:11:41 Voltage Offset Correction: v_off_ini = 654.420 uV, v_off_fin = 660.112 uV 11:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.783 uVs 11:11:41 Integrated Voltage Measurement... 11:11:50 Voltage Offset Correction: v_off_ini = 652.784 uV, v_off_fin = 647.950 uV 11:11:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 224.864 uVs 11:11:51 Integrated Voltage Measurement... 11:11:59 Voltage Offset Correction: v_off_ini = 679.279 uV, v_off_fin = 619.386 uV 11:12:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -290.841 uVs 11:12:00 Integrated Voltage Measurement... 11:12:09 Voltage Offset Correction: v_off_ini = 630.015 uV, v_off_fin = 591.642 uV 11:12:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 277.400 uVs 11:12:09 Integrated Voltage Measurement... 11:12:18 Voltage Offset Correction: v_off_ini = 684.143 uV, v_off_fin = 663.387 uV 11:12:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.060 uVs 11:12:18 Integrated Voltage Measurement... 11:12:27 Voltage Offset Correction: v_off_ini = 655.651 uV, v_off_fin = 647.978 uV 11:12:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.854 uVs 11:12:29 I2Y Average and RMS of Measurements VT = -239.967 +- 31.243 uVs I2Y = -22.078 +- 2.875 uTm^2 11:12:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:12:43 Integrated Voltage Measurement... 11:12:52 Voltage Offset Correction: v_off_ini = 629.488 uV, v_off_fin = 674.641 uV 11:12:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.320 uVs 11:12:52 Integrated Voltage Measurement... 11:13:01 Voltage Offset Correction: v_off_ini = 644.022 uV, v_off_fin = 651.295 uV 11:13:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.368 uVs 11:13:01 Integrated Voltage Measurement... 11:13:10 Voltage Offset Correction: v_off_ini = 653.973 uV, v_off_fin = 694.791 uV 11:13:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 5.822 uVs 11:13:10 Integrated Voltage Measurement... 11:13:19 Voltage Offset Correction: v_off_ini = 613.191 uV, v_off_fin = 646.336 uV 11:13:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.679 uVs 11:13:19 Integrated Voltage Measurement... 11:13:28 Voltage Offset Correction: v_off_ini = 662.560 uV, v_off_fin = 629.752 uV 11:13:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.817 uVs 11:13:28 Integrated Voltage Measurement... 11:13:37 Voltage Offset Correction: v_off_ini = 675.605 uV, v_off_fin = 653.951 uV 11:13:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 17.000 uVs 11:13:41 I1X Average and RMS of Measurements VT = -44.727 +- 12.593 uVs I1X = 8.946 +- 2.519 uTm 11:13:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:13:48 Integrated Voltage Measurement... 11:13:57 Voltage Offset Correction: v_off_ini = 650.158 uV, v_off_fin = 641.807 uV 11:13:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -245.673 uVs 11:13:57 Integrated Voltage Measurement... 11:14:06 Voltage Offset Correction: v_off_ini = 653.696 uV, v_off_fin = 669.200 uV 11:14:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.940 uVs 11:14:06 Integrated Voltage Measurement... 11:14:15 Voltage Offset Correction: v_off_ini = 630.643 uV, v_off_fin = 620.572 uV 11:14:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -251.939 uVs 11:14:15 Integrated Voltage Measurement... 11:14:24 Voltage Offset Correction: v_off_ini = 635.776 uV, v_off_fin = 634.771 uV 11:14:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.314 uVs 11:14:24 Integrated Voltage Measurement... 11:14:33 Voltage Offset Correction: v_off_ini = 609.348 uV, v_off_fin = 599.588 uV 11:14:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.742 uVs 11:14:33 Integrated Voltage Measurement... 11:14:42 Voltage Offset Correction: v_off_ini = 653.293 uV, v_off_fin = 633.515 uV 11:14:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.542 uVs 11:14:46 I1Y Average and RMS of Measurements VT = -226.358 +- 8.481 uVs I1Y = -45.270 +- 1.697 uTm 11:14:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:14:54 Integrated Voltage Measurement... 11:15:03 Voltage Offset Correction: v_off_ini = 613.398 uV, v_off_fin = 591.824 uV 11:15:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.755 uVs 11:15:03 Integrated Voltage Measurement... 11:15:12 Voltage Offset Correction: v_off_ini = 625.152 uV, v_off_fin = 639.436 uV 11:15:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.387 uVs 11:15:12 Integrated Voltage Measurement... 11:15:21 Voltage Offset Correction: v_off_ini = 671.809 uV, v_off_fin = 639.556 uV 11:15:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -45.321 uVs 11:15:21 Integrated Voltage Measurement... 11:15:30 Voltage Offset Correction: v_off_ini = 653.829 uV, v_off_fin = 661.638 uV 11:15:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.148 uVs 11:15:30 Integrated Voltage Measurement... 11:15:39 Voltage Offset Correction: v_off_ini = 621.040 uV, v_off_fin = 605.968 uV 11:15:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.580 uVs 11:15:39 Integrated Voltage Measurement... 11:15:48 Voltage Offset Correction: v_off_ini = 632.717 uV, v_off_fin = 627.526 uV 11:15:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 30.756 uVs 11:15:51 I2X Average and RMS of Measurements VT = -54.824 +- 8.330 uVs I2X = 5.044 +- 0.766 uTm^2 11:15:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:15:59 Integrated Voltage Measurement... 11:16:08 Voltage Offset Correction: v_off_ini = 673.043 uV, v_off_fin = 694.885 uV 11:16:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.167 uVs 11:16:08 Integrated Voltage Measurement... 11:16:17 Voltage Offset Correction: v_off_ini = 682.944 uV, v_off_fin = 668.823 uV 11:16:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.569 uVs 11:16:17 Integrated Voltage Measurement... 11:16:26 Voltage Offset Correction: v_off_ini = 684.961 uV, v_off_fin = 704.074 uV 11:16:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.907 uVs 11:16:26 Integrated Voltage Measurement... 11:16:35 Voltage Offset Correction: v_off_ini = 662.426 uV, v_off_fin = 672.274 uV 11:16:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.068 uVs 11:16:35 Integrated Voltage Measurement... 11:16:44 Voltage Offset Correction: v_off_ini = 643.231 uV, v_off_fin = 653.670 uV 11:16:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.674 uVs 11:16:44 Integrated Voltage Measurement... 11:16:53 Voltage Offset Correction: v_off_ini = 686.335 uV, v_off_fin = 685.268 uV 11:16:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.311 uVs 11:16:55 I2Y Average and RMS of Measurements VT = -251.616 +- 3.106 uVs I2Y = -23.149 +- 0.286 uTm^2 11:17:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:17:09 Integrated Voltage Measurement... 11:17:18 Voltage Offset Correction: v_off_ini = 692.356 uV, v_off_fin = 645.964 uV 11:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -42.878 uVs 11:17:18 Integrated Voltage Measurement... 11:17:27 Voltage Offset Correction: v_off_ini = 674.475 uV, v_off_fin = 676.963 uV 11:17:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 8.125 uVs 11:17:27 Integrated Voltage Measurement... 11:17:36 Voltage Offset Correction: v_off_ini = 700.145 uV, v_off_fin = 679.196 uV 11:17:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.924 uVs 11:17:36 Integrated Voltage Measurement... 11:17:45 Voltage Offset Correction: v_off_ini = 686.339 uV, v_off_fin = 683.508 uV 11:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.254 uVs 11:17:45 Integrated Voltage Measurement... 11:17:54 Voltage Offset Correction: v_off_ini = 646.821 uV, v_off_fin = 661.519 uV 11:17:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.380 uVs 11:17:54 Integrated Voltage Measurement... 11:18:03 Voltage Offset Correction: v_off_ini = 670.032 uV, v_off_fin = 663.876 uV 11:18:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.588 uVs 11:18:08 I1X Average and RMS of Measurements VT = -38.858 +- 9.654 uVs I1X = 7.772 +- 1.931 uTm 11:18:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:18:14 Integrated Voltage Measurement... 11:18:23 Voltage Offset Correction: v_off_ini = 693.113 uV, v_off_fin = 708.891 uV 11:18:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -210.673 uVs 11:18:23 Integrated Voltage Measurement... 11:18:32 Voltage Offset Correction: v_off_ini = 697.121 uV, v_off_fin = 734.826 uV 11:18:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.741 uVs 11:18:32 Integrated Voltage Measurement... 11:18:41 Voltage Offset Correction: v_off_ini = 693.073 uV, v_off_fin = 632.634 uV 11:18:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.263 uVs 11:18:41 Integrated Voltage Measurement... 11:18:50 Voltage Offset Correction: v_off_ini = 661.642 uV, v_off_fin = 693.157 uV 11:18:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.300 uVs 11:18:50 Integrated Voltage Measurement... 11:18:59 Voltage Offset Correction: v_off_ini = 695.993 uV, v_off_fin = 677.927 uV 11:18:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.525 uVs 11:18:59 Integrated Voltage Measurement... 11:19:08 Voltage Offset Correction: v_off_ini = 736.685 uV, v_off_fin = 736.500 uV 11:19:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.981 uVs 11:19:13 I1Y Average and RMS of Measurements VT = -217.914 +- 6.461 uVs I1Y = -43.583 +- 1.293 uTm 11:19:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:19:20 Integrated Voltage Measurement... 11:19:29 Voltage Offset Correction: v_off_ini = 705.566 uV, v_off_fin = 721.245 uV 11:19:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -26.277 uVs 11:19:29 Integrated Voltage Measurement... 11:19:38 Voltage Offset Correction: v_off_ini = 729.829 uV, v_off_fin = 742.689 uV 11:19:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.263 uVs 11:19:38 Integrated Voltage Measurement... 11:19:47 Voltage Offset Correction: v_off_ini = 699.570 uV, v_off_fin = 721.248 uV 11:19:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 7.488 uVs 11:19:47 Integrated Voltage Measurement... 11:19:56 Voltage Offset Correction: v_off_ini = 733.127 uV, v_off_fin = 724.528 uV 11:19:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 28.631 uVs 11:19:57 Integrated Voltage Measurement... 11:20:06 Voltage Offset Correction: v_off_ini = 703.205 uV, v_off_fin = 715.819 uV 11:20:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -27.810 uVs 11:20:06 Integrated Voltage Measurement... 11:20:15 Voltage Offset Correction: v_off_ini = 728.273 uV, v_off_fin = 724.533 uV 11:20:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.493 uVs 11:20:17 I2X Average and RMS of Measurements VT = -32.998 +- 16.840 uVs I2X = 3.036 +- 1.549 uTm^2 11:20:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:20:25 Integrated Voltage Measurement... 11:20:34 Voltage Offset Correction: v_off_ini = 700.180 uV, v_off_fin = 745.824 uV 11:20:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.400 uVs 11:20:34 Integrated Voltage Measurement... 11:20:43 Voltage Offset Correction: v_off_ini = 735.401 uV, v_off_fin = 722.317 uV 11:20:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.507 uVs 11:20:43 Integrated Voltage Measurement... 11:20:52 Voltage Offset Correction: v_off_ini = 789.333 uV, v_off_fin = 716.557 uV 11:20:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.406 uVs 11:20:52 Integrated Voltage Measurement... 11:21:01 Voltage Offset Correction: v_off_ini = 684.678 uV, v_off_fin = 694.667 uV 11:21:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.262 uVs 11:21:01 Integrated Voltage Measurement... 11:21:10 Voltage Offset Correction: v_off_ini = 713.213 uV, v_off_fin = 713.059 uV 11:21:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.002 uVs 11:21:10 Integrated Voltage Measurement... 11:21:19 Voltage Offset Correction: v_off_ini = 713.814 uV, v_off_fin = 694.495 uV 11:21:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.093 uVs 11:21:21 I2Y Average and RMS of Measurements VT = -260.778 +- 14.254 uVs I2Y = -23.992 +- 1.311 uTm^2 11:21:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:21:37 Integrated Voltage Measurement... 11:21:46 Voltage Offset Correction: v_off_ini = 702.542 uV, v_off_fin = 677.527 uV 11:21:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -52.254 uVs 11:21:46 Integrated Voltage Measurement... 11:21:55 Voltage Offset Correction: v_off_ini = 695.681 uV, v_off_fin = 688.569 uV 11:21:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.634 uVs 11:21:55 Integrated Voltage Measurement... 11:22:04 Voltage Offset Correction: v_off_ini = 671.382 uV, v_off_fin = 704.264 uV 11:22:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.598 uVs 11:22:04 Integrated Voltage Measurement... 11:22:13 Voltage Offset Correction: v_off_ini = 682.084 uV, v_off_fin = 657.045 uV 11:22:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.904 uVs 11:22:13 Integrated Voltage Measurement... 11:22:22 Voltage Offset Correction: v_off_ini = 706.657 uV, v_off_fin = 677.843 uV 11:22:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.691 uVs 11:22:22 Integrated Voltage Measurement... 11:22:31 Voltage Offset Correction: v_off_ini = 711.472 uV, v_off_fin = 708.871 uV 11:22:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.618 uVs 11:22:35 I1X Average and RMS of Measurements VT = -47.783 +- 5.505 uVs I1X = 9.557 +- 1.101 uTm 11:22:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:42 Integrated Voltage Measurement... 11:22:51 Voltage Offset Correction: v_off_ini = 672.705 uV, v_off_fin = 682.261 uV 11:22:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.670 uVs 11:22:51 Integrated Voltage Measurement... 11:23:00 Voltage Offset Correction: v_off_ini = 723.455 uV, v_off_fin = 693.100 uV 11:23:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.040 uVs 11:23:00 Integrated Voltage Measurement... 11:23:09 Voltage Offset Correction: v_off_ini = 667.357 uV, v_off_fin = 670.110 uV 11:23:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.793 uVs 11:23:09 Integrated Voltage Measurement... 11:23:18 Voltage Offset Correction: v_off_ini = 753.539 uV, v_off_fin = 753.454 uV 11:23:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.879 uVs 11:23:18 Integrated Voltage Measurement... 11:23:27 Voltage Offset Correction: v_off_ini = 720.916 uV, v_off_fin = 691.589 uV 11:23:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.811 uVs 11:23:27 Integrated Voltage Measurement... 11:23:36 Voltage Offset Correction: v_off_ini = 732.932 uV, v_off_fin = 736.147 uV 11:23:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.948 uVs 11:23:40 I1Y Average and RMS of Measurements VT = -217.690 +- 6.157 uVs I1Y = -43.535 +- 1.232 uTm 11:23:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:23:48 Integrated Voltage Measurement... 11:23:57 Voltage Offset Correction: v_off_ini = 692.199 uV, v_off_fin = 716.832 uV 11:23:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -16.736 uVs 11:23:57 Integrated Voltage Measurement... 11:24:06 Voltage Offset Correction: v_off_ini = 721.384 uV, v_off_fin = 714.080 uV 11:24:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.756 uVs 11:24:06 Integrated Voltage Measurement... 11:24:15 Voltage Offset Correction: v_off_ini = 699.175 uV, v_off_fin = 717.758 uV 11:24:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -9.092 uVs 11:24:15 Integrated Voltage Measurement... 11:24:24 Voltage Offset Correction: v_off_ini = 712.950 uV, v_off_fin = 738.473 uV 11:24:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 6.518 uVs 11:24:24 Integrated Voltage Measurement... 11:24:33 Voltage Offset Correction: v_off_ini = 721.086 uV, v_off_fin = 734.173 uV 11:24:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -35.972 uVs 11:24:33 Integrated Voltage Measurement... 11:24:42 Voltage Offset Correction: v_off_ini = 686.022 uV, v_off_fin = 734.879 uV 11:24:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 12.767 uVs 11:24:45 I2X Average and RMS of Measurements VT = -22.474 +- 11.282 uVs I2X = 2.068 +- 1.038 uTm^2 11:24:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:24:52 Integrated Voltage Measurement... 11:25:01 Voltage Offset Correction: v_off_ini = 677.706 uV, v_off_fin = 671.501 uV 11:25:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.217 uVs 11:25:01 Integrated Voltage Measurement... 11:25:10 Voltage Offset Correction: v_off_ini = 706.261 uV, v_off_fin = 689.172 uV 11:25:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.896 uVs 11:25:10 Integrated Voltage Measurement... 11:25:19 Voltage Offset Correction: v_off_ini = 685.931 uV, v_off_fin = 703.170 uV 11:25:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.330 uVs 11:25:19 Integrated Voltage Measurement... 11:25:28 Voltage Offset Correction: v_off_ini = 718.471 uV, v_off_fin = 735.574 uV 11:25:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.491 uVs 11:25:29 Integrated Voltage Measurement... 11:25:38 Voltage Offset Correction: v_off_ini = 737.569 uV, v_off_fin = 720.411 uV 11:25:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.927 uVs 11:25:38 Integrated Voltage Measurement... 11:25:47 Voltage Offset Correction: v_off_ini = 742.522 uV, v_off_fin = 720.337 uV 11:25:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.093 uVs 11:25:49 I2Y Average and RMS of Measurements VT = -247.492 +- 3.953 uVs I2Y = -22.769 +- 0.364 uTm^2 11:26:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:26:04 Integrated Voltage Measurement... 11:26:13 Voltage Offset Correction: v_off_ini = 707.466 uV, v_off_fin = 707.160 uV 11:26:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.587 uVs 11:26:13 Integrated Voltage Measurement... 11:26:22 Voltage Offset Correction: v_off_ini = 710.068 uV, v_off_fin = 690.846 uV 11:26:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.955 uVs 11:26:22 Integrated Voltage Measurement... 11:26:31 Voltage Offset Correction: v_off_ini = 699.538 uV, v_off_fin = 679.963 uV 11:26:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.598 uVs 11:26:31 Integrated Voltage Measurement... 11:26:40 Voltage Offset Correction: v_off_ini = 680.523 uV, v_off_fin = 698.662 uV 11:26:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.015 uVs 11:26:40 Integrated Voltage Measurement... 11:26:49 Voltage Offset Correction: v_off_ini = 685.420 uV, v_off_fin = 705.066 uV 11:26:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.870 uVs 11:26:49 Integrated Voltage Measurement... 11:26:58 Voltage Offset Correction: v_off_ini = 715.467 uV, v_off_fin = 700.788 uV 11:26:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.102 uVs 11:27:02 I1X Average and RMS of Measurements VT = -58.688 +- 16.287 uVs I1X = 11.738 +- 3.257 uTm 11:27:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:27:09 Integrated Voltage Measurement... 11:27:18 Voltage Offset Correction: v_off_ini = 736.080 uV, v_off_fin = 712.367 uV 11:27:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.898 uVs 11:27:18 Integrated Voltage Measurement... 11:27:27 Voltage Offset Correction: v_off_ini = 682.121 uV, v_off_fin = 691.589 uV 11:27:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 193.628 uVs 11:27:27 Integrated Voltage Measurement... 11:27:36 Voltage Offset Correction: v_off_ini = 738.855 uV, v_off_fin = 706.457 uV 11:27:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -251.711 uVs 11:27:36 Integrated Voltage Measurement... 11:27:45 Voltage Offset Correction: v_off_ini = 726.137 uV, v_off_fin = 727.142 uV 11:27:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 231.277 uVs 11:27:45 Integrated Voltage Measurement... 11:27:54 Voltage Offset Correction: v_off_ini = 714.859 uV, v_off_fin = 677.103 uV 11:27:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -261.726 uVs 11:27:54 Integrated Voltage Measurement... 11:28:03 Voltage Offset Correction: v_off_ini = 694.538 uV, v_off_fin = 683.875 uV 11:28:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 226.776 uVs 11:28:08 I1Y Average and RMS of Measurements VT = -234.503 +- 11.890 uVs I1Y = -46.893 +- 2.375 uTm 11:28:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:28:15 Integrated Voltage Measurement... 11:28:24 Voltage Offset Correction: v_off_ini = 773.954 uV, v_off_fin = 711.793 uV 11:28:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -55.606 uVs 11:28:24 Integrated Voltage Measurement... 11:28:33 Voltage Offset Correction: v_off_ini = 702.474 uV, v_off_fin = 705.226 uV 11:28:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 65.293 uVs 11:28:33 Integrated Voltage Measurement... 11:28:42 Voltage Offset Correction: v_off_ini = 669.549 uV, v_off_fin = 715.035 uV 11:28:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -59.008 uVs 11:28:42 Integrated Voltage Measurement... 11:28:51 Voltage Offset Correction: v_off_ini = 707.373 uV, v_off_fin = 696.633 uV 11:28:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.008 uVs 11:28:51 Integrated Voltage Measurement... 11:29:00 Voltage Offset Correction: v_off_ini = 718.961 uV, v_off_fin = 716.901 uV 11:29:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -16.923 uVs 11:29:01 Integrated Voltage Measurement... 11:29:10 Voltage Offset Correction: v_off_ini = 712.113 uV, v_off_fin = 714.396 uV 11:29:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.814 uVs 11:29:12 I2X Average and RMS of Measurements VT = -46.442 +- 19.498 uVs I2X = 4.273 +- 1.794 uTm^2 11:29:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:29:20 Integrated Voltage Measurement... 11:29:29 Voltage Offset Correction: v_off_ini = 743.789 uV, v_off_fin = 734.198 uV 11:29:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.174 uVs 11:29:29 Integrated Voltage Measurement... 11:29:38 Voltage Offset Correction: v_off_ini = 720.654 uV, v_off_fin = 727.849 uV 11:29:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.632 uVs 11:29:38 Integrated Voltage Measurement... 11:29:47 Voltage Offset Correction: v_off_ini = 707.385 uV, v_off_fin = 699.188 uV 11:29:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.958 uVs 11:29:47 Integrated Voltage Measurement... 11:29:56 Voltage Offset Correction: v_off_ini = 697.610 uV, v_off_fin = 686.955 uV 11:29:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.971 uVs 11:29:56 Integrated Voltage Measurement... 11:30:05 Voltage Offset Correction: v_off_ini = 647.716 uV, v_off_fin = 717.634 uV 11:30:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.319 uVs 11:30:05 Integrated Voltage Measurement... 11:30:14 Voltage Offset Correction: v_off_ini = 737.273 uV, v_off_fin = 707.202 uV 11:30:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.450 uVs 11:30:16 I2Y Average and RMS of Measurements VT = -244.751 +- 9.584 uVs I2Y = -22.517 +- 0.882 uTm^2 11:30:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:30:34 Integrated Voltage Measurement... 11:30:43 Voltage Offset Correction: v_off_ini = 694.869 uV, v_off_fin = 705.843 uV 11:30:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.911 uVs 11:30:43 Integrated Voltage Measurement... 11:30:52 Voltage Offset Correction: v_off_ini = 725.731 uV, v_off_fin = 683.793 uV 11:30:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.064 uVs 11:30:52 Integrated Voltage Measurement... 11:31:01 Voltage Offset Correction: v_off_ini = 678.138 uV, v_off_fin = 707.889 uV 11:31:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.418 uVs 11:31:01 Integrated Voltage Measurement... 11:31:10 Voltage Offset Correction: v_off_ini = 714.454 uV, v_off_fin = 696.870 uV 11:31:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.553 uVs 11:31:10 Integrated Voltage Measurement... 11:31:19 Voltage Offset Correction: v_off_ini = 679.973 uV, v_off_fin = 699.479 uV 11:31:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.169 uVs 11:31:19 Integrated Voltage Measurement... 11:31:28 Voltage Offset Correction: v_off_ini = 661.191 uV, v_off_fin = 694.505 uV 11:31:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.377 uVs 11:31:32 I1X Average and RMS of Measurements VT = -52.415 +- 11.519 uVs I1X = 10.483 +- 2.304 uTm 11:31:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:39 Integrated Voltage Measurement... 11:31:48 Voltage Offset Correction: v_off_ini = 668.878 uV, v_off_fin = 649.844 uV 11:31:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.034 uVs 11:31:48 Integrated Voltage Measurement... 11:31:57 Voltage Offset Correction: v_off_ini = 668.258 uV, v_off_fin = 735.632 uV 11:31:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 210.569 uVs 11:31:57 Integrated Voltage Measurement... 11:32:06 Voltage Offset Correction: v_off_ini = 670.477 uV, v_off_fin = 660.019 uV 11:32:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.892 uVs 11:32:06 Integrated Voltage Measurement... 11:32:15 Voltage Offset Correction: v_off_ini = 680.685 uV, v_off_fin = 714.273 uV 11:32:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 200.031 uVs 11:32:15 Integrated Voltage Measurement... 11:32:24 Voltage Offset Correction: v_off_ini = 721.784 uV, v_off_fin = 656.440 uV 11:32:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -229.026 uVs 11:32:24 Integrated Voltage Measurement... 11:32:33 Voltage Offset Correction: v_off_ini = 676.207 uV, v_off_fin = 727.893 uV 11:32:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 225.310 uVs 11:32:37 I1Y Average and RMS of Measurements VT = -216.643 +- 7.949 uVs I1Y = -43.322 +- 1.588 uTm 11:32:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:32:45 Integrated Voltage Measurement... 11:32:54 Voltage Offset Correction: v_off_ini = 652.662 uV, v_off_fin = 729.572 uV 11:32:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -1.714 uVs 11:32:54 Integrated Voltage Measurement... 11:33:03 Voltage Offset Correction: v_off_ini = 729.375 uV, v_off_fin = 752.235 uV 11:33:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.771 uVs 11:33:03 Integrated Voltage Measurement... 11:33:12 Voltage Offset Correction: v_off_ini = 722.927 uV, v_off_fin = 710.234 uV 11:33:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.684 uVs 11:33:12 Integrated Voltage Measurement... 11:33:21 Voltage Offset Correction: v_off_ini = 693.548 uV, v_off_fin = 691.307 uV 11:33:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.432 uVs 11:33:21 Integrated Voltage Measurement... 11:33:30 Voltage Offset Correction: v_off_ini = 717.417 uV, v_off_fin = 695.043 uV 11:33:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -2.478 uVs 11:33:30 Integrated Voltage Measurement... 11:33:39 Voltage Offset Correction: v_off_ini = 737.932 uV, v_off_fin = 745.375 uV 11:33:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.258 uVs 11:33:42 I2X Average and RMS of Measurements VT = -39.056 +- 13.633 uVs I2X = 3.593 +- 1.254 uTm^2 11:33:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:33:49 Integrated Voltage Measurement... 11:33:58 Voltage Offset Correction: v_off_ini = 710.814 uV, v_off_fin = 687.466 uV 11:33:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.394 uVs 11:33:58 Integrated Voltage Measurement... 11:34:07 Voltage Offset Correction: v_off_ini = 683.129 uV, v_off_fin = 720.742 uV 11:34:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.303 uVs 11:34:07 Integrated Voltage Measurement... 11:34:16 Voltage Offset Correction: v_off_ini = 686.430 uV, v_off_fin = 690.110 uV 11:34:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.439 uVs 11:34:17 Integrated Voltage Measurement... 11:34:26 Voltage Offset Correction: v_off_ini = 732.631 uV, v_off_fin = 723.720 uV 11:34:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.855 uVs 11:34:26 Integrated Voltage Measurement... 11:34:35 Voltage Offset Correction: v_off_ini = 734.212 uV, v_off_fin = 754.513 uV 11:34:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.484 uVs 11:34:35 Integrated Voltage Measurement... 11:34:44 Voltage Offset Correction: v_off_ini = 684.021 uV, v_off_fin = 748.485 uV 11:34:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.577 uVs 11:34:46 I2Y Average and RMS of Measurements VT = -232.509 +- 27.422 uVs I2Y = -21.391 +- 2.523 uTm^2 11:34:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:35:03 Integrated Voltage Measurement... 11:35:12 Voltage Offset Correction: v_off_ini = 698.359 uV, v_off_fin = 705.901 uV 11:35:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -51.665 uVs 11:35:12 Integrated Voltage Measurement... 11:35:21 Voltage Offset Correction: v_off_ini = 683.753 uV, v_off_fin = 704.890 uV 11:35:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.023 uVs 11:35:21 Integrated Voltage Measurement... 11:35:30 Voltage Offset Correction: v_off_ini = 713.710 uV, v_off_fin = 716.253 uV 11:35:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.959 uVs 11:35:30 Integrated Voltage Measurement... 11:35:39 Voltage Offset Correction: v_off_ini = 735.184 uV, v_off_fin = 745.933 uV 11:35:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.937 uVs 11:35:40 Integrated Voltage Measurement... 11:35:49 Voltage Offset Correction: v_off_ini = 700.428 uV, v_off_fin = 758.621 uV 11:35:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.428 uVs 11:35:49 Integrated Voltage Measurement... 11:35:58 Voltage Offset Correction: v_off_ini = 724.769 uV, v_off_fin = 755.147 uV 11:35:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.235 uVs 11:36:02 I1X Average and RMS of Measurements VT = -57.041 +- 8.158 uVs I1X = 11.409 +- 1.631 uTm 11:36:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:09 Integrated Voltage Measurement... 11:36:18 Voltage Offset Correction: v_off_ini = 778.091 uV, v_off_fin = 736.446 uV 11:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -255.123 uVs 11:36:18 Integrated Voltage Measurement... 11:36:27 Voltage Offset Correction: v_off_ini = 756.671 uV, v_off_fin = 772.170 uV 11:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 248.427 uVs 11:36:27 Integrated Voltage Measurement... 11:36:36 Voltage Offset Correction: v_off_ini = 769.759 uV, v_off_fin = 757.786 uV 11:36:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -233.201 uVs 11:36:36 Integrated Voltage Measurement... 11:36:45 Voltage Offset Correction: v_off_ini = 751.092 uV, v_off_fin = 767.020 uV 11:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 223.768 uVs 11:36:45 Integrated Voltage Measurement... 11:36:54 Voltage Offset Correction: v_off_ini = 785.534 uV, v_off_fin = 788.793 uV 11:36:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -262.663 uVs 11:36:54 Integrated Voltage Measurement... 11:37:03 Voltage Offset Correction: v_off_ini = 765.994 uV, v_off_fin = 784.790 uV 11:37:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 231.123 uVs 11:37:07 I1Y Average and RMS of Measurements VT = -242.384 +- 10.029 uVs I1Y = -48.469 +- 2.005 uTm 11:37:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:37:15 Integrated Voltage Measurement... 11:37:24 Voltage Offset Correction: v_off_ini = 755.835 uV, v_off_fin = 773.333 uV 11:37:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.323 uVs 11:37:24 Integrated Voltage Measurement... 11:37:33 Voltage Offset Correction: v_off_ini = 780.120 uV, v_off_fin = 796.371 uV 11:37:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.178 uVs 11:37:33 Integrated Voltage Measurement... 11:37:42 Voltage Offset Correction: v_off_ini = 788.952 uV, v_off_fin = 773.626 uV 11:37:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.146 uVs 11:37:42 Integrated Voltage Measurement... 11:37:51 Voltage Offset Correction: v_off_ini = 738.572 uV, v_off_fin = 795.917 uV 11:37:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.205 uVs 11:37:51 Integrated Voltage Measurement... 11:38:00 Voltage Offset Correction: v_off_ini = 785.368 uV, v_off_fin = 775.393 uV 11:38:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -86.894 uVs 11:38:00 Integrated Voltage Measurement... 11:38:09 Voltage Offset Correction: v_off_ini = 756.998 uV, v_off_fin = 766.710 uV 11:38:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.523 uVs 11:38:11 I2X Average and RMS of Measurements VT = -78.878 +- 12.027 uVs I2X = 7.257 +- 1.107 uTm^2 11:38:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:38:19 Integrated Voltage Measurement... 11:38:28 Voltage Offset Correction: v_off_ini = 813.309 uV, v_off_fin = 764.304 uV 11:38:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.840 uVs 11:38:28 Integrated Voltage Measurement... 11:38:37 Voltage Offset Correction: v_off_ini = 788.551 uV, v_off_fin = 761.492 uV 11:38:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.869 uVs 11:38:37 Integrated Voltage Measurement... 11:38:46 Voltage Offset Correction: v_off_ini = 757.745 uV, v_off_fin = 759.526 uV 11:38:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.771 uVs 11:38:46 Integrated Voltage Measurement... 11:38:55 Voltage Offset Correction: v_off_ini = 795.730 uV, v_off_fin = 793.850 uV 11:38:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.512 uVs 11:38:55 Integrated Voltage Measurement... 11:39:04 Voltage Offset Correction: v_off_ini = 767.027 uV, v_off_fin = 767.858 uV 11:39:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.231 uVs 11:39:04 Integrated Voltage Measurement... 11:39:13 Voltage Offset Correction: v_off_ini = 786.026 uV, v_off_fin = 776.878 uV 11:39:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.023 uVs 11:39:16 I2Y Average and RMS of Measurements VT = -243.208 +- 17.898 uVs I2Y = -22.375 +- 1.647 uTm^2 11:39:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:33 Integrated Voltage Measurement... 11:39:42 Voltage Offset Correction: v_off_ini = 763.298 uV, v_off_fin = 754.542 uV 11:39:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.166 uVs 11:39:42 Integrated Voltage Measurement... 11:39:51 Voltage Offset Correction: v_off_ini = 773.764 uV, v_off_fin = 803.534 uV 11:39:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.159 uVs 11:39:51 Integrated Voltage Measurement... 11:40:00 Voltage Offset Correction: v_off_ini = 795.299 uV, v_off_fin = 739.478 uV 11:40:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.773 uVs 11:40:00 Integrated Voltage Measurement... 11:40:09 Voltage Offset Correction: v_off_ini = 731.881 uV, v_off_fin = 746.662 uV 11:40:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.701 uVs 11:40:09 Integrated Voltage Measurement... 11:40:18 Voltage Offset Correction: v_off_ini = 733.808 uV, v_off_fin = 772.775 uV 11:40:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.023 uVs 11:40:18 Integrated Voltage Measurement... 11:40:27 Voltage Offset Correction: v_off_ini = 812.430 uV, v_off_fin = 786.112 uV 11:40:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.951 uVs 11:40:32 I1X Average and RMS of Measurements VT = -72.462 +- 17.311 uVs I1X = 14.493 +- 3.462 uTm 11:40:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:40:38 Integrated Voltage Measurement... 11:40:47 Voltage Offset Correction: v_off_ini = 789.167 uV, v_off_fin = 765.623 uV 11:40:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.409 uVs 11:40:47 Integrated Voltage Measurement... 11:40:56 Voltage Offset Correction: v_off_ini = 792.772 uV, v_off_fin = 807.227 uV 11:40:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 260.310 uVs 11:40:56 Integrated Voltage Measurement... 11:41:05 Voltage Offset Correction: v_off_ini = 765.559 uV, v_off_fin = 771.235 uV 11:41:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.339 uVs 11:41:05 Integrated Voltage Measurement... 11:41:14 Voltage Offset Correction: v_off_ini = 760.591 uV, v_off_fin = 789.203 uV 11:41:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 258.228 uVs 11:41:14 Integrated Voltage Measurement... 11:41:23 Voltage Offset Correction: v_off_ini = 793.309 uV, v_off_fin = 764.699 uV 11:41:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -251.758 uVs 11:41:23 Integrated Voltage Measurement... 11:41:32 Voltage Offset Correction: v_off_ini = 777.334 uV, v_off_fin = 761.162 uV 11:41:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.376 uVs 11:41:37 I1Y Average and RMS of Measurements VT = -249.236 +- 6.740 uVs I1Y = -49.841 +- 1.349 uTm 11:41:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:41:44 Integrated Voltage Measurement... 11:41:53 Voltage Offset Correction: v_off_ini = 775.298 uV, v_off_fin = 773.672 uV 11:41:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -145.631 uVs 11:41:53 Integrated Voltage Measurement... 11:42:02 Voltage Offset Correction: v_off_ini = 790.403 uV, v_off_fin = 798.715 uV 11:42:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.121 uVs 11:42:03 Integrated Voltage Measurement... 11:42:11 Voltage Offset Correction: v_off_ini = 741.392 uV, v_off_fin = 777.089 uV 11:42:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.098 uVs 11:42:12 Integrated Voltage Measurement... 11:42:21 Voltage Offset Correction: v_off_ini = 759.525 uV, v_off_fin = 812.850 uV 11:42:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.979 uVs 11:42:21 Integrated Voltage Measurement... 11:42:30 Voltage Offset Correction: v_off_ini = 772.930 uV, v_off_fin = 780.356 uV 11:42:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.749 uVs 11:42:30 Integrated Voltage Measurement... 11:42:39 Voltage Offset Correction: v_off_ini = 771.690 uV, v_off_fin = 757.881 uV 11:42:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.834 uVs 11:42:41 I2X Average and RMS of Measurements VT = -71.069 +- 38.927 uVs I2X = 6.539 +- 3.582 uTm^2 11:42:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:42:49 Integrated Voltage Measurement... 11:42:58 Voltage Offset Correction: v_off_ini = 746.237 uV, v_off_fin = 762.874 uV 11:42:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.535 uVs 11:42:58 Integrated Voltage Measurement... 11:43:07 Voltage Offset Correction: v_off_ini = 752.545 uV, v_off_fin = 773.871 uV 11:43:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.642 uVs 11:43:07 Integrated Voltage Measurement... 11:43:16 Voltage Offset Correction: v_off_ini = 753.985 uV, v_off_fin = 754.786 uV 11:43:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.532 uVs 11:43:16 Integrated Voltage Measurement... 11:43:25 Voltage Offset Correction: v_off_ini = 774.827 uV, v_off_fin = 773.309 uV 11:43:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.180 uVs 11:43:25 Integrated Voltage Measurement... 11:43:34 Voltage Offset Correction: v_off_ini = 771.749 uV, v_off_fin = 765.939 uV 11:43:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.401 uVs 11:43:34 Integrated Voltage Measurement... 11:43:43 Voltage Offset Correction: v_off_ini = 771.898 uV, v_off_fin = 769.527 uV 11:43:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.597 uVs 11:43:46 I2Y Average and RMS of Measurements VT = -246.148 +- 6.836 uVs I2Y = -22.646 +- 0.629 uTm^2 11:43:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:44:03 Integrated Voltage Measurement... 11:44:12 Voltage Offset Correction: v_off_ini = 738.724 uV, v_off_fin = 740.198 uV 11:44:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.856 uVs 11:44:12 Integrated Voltage Measurement... 11:44:21 Voltage Offset Correction: v_off_ini = 742.905 uV, v_off_fin = 714.483 uV 11:44:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.971 uVs 11:44:21 Integrated Voltage Measurement... 11:44:30 Voltage Offset Correction: v_off_ini = 751.362 uV, v_off_fin = 743.463 uV 11:44:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.517 uVs 11:44:30 Integrated Voltage Measurement... 11:44:39 Voltage Offset Correction: v_off_ini = 783.868 uV, v_off_fin = 758.782 uV 11:44:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.550 uVs 11:44:39 Integrated Voltage Measurement... 11:44:48 Voltage Offset Correction: v_off_ini = 752.411 uV, v_off_fin = 750.946 uV 11:44:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.025 uVs 11:44:49 Integrated Voltage Measurement... 11:44:58 Voltage Offset Correction: v_off_ini = 771.721 uV, v_off_fin = 764.044 uV 11:44:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.514 uVs 11:45:03 I1X Average and RMS of Measurements VT = -91.905 +- 6.173 uVs I1X = 18.381 +- 1.234 uTm 11:45:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:09 Integrated Voltage Measurement... 11:45:18 Voltage Offset Correction: v_off_ini = 762.070 uV, v_off_fin = 745.133 uV 11:45:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.005 uVs 11:45:18 Integrated Voltage Measurement... 11:45:27 Voltage Offset Correction: v_off_ini = 771.271 uV, v_off_fin = 741.287 uV 11:45:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 246.996 uVs 11:45:27 Integrated Voltage Measurement... 11:45:36 Voltage Offset Correction: v_off_ini = 776.528 uV, v_off_fin = 775.126 uV 11:45:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -269.998 uVs 11:45:36 Integrated Voltage Measurement... 11:45:45 Voltage Offset Correction: v_off_ini = 775.256 uV, v_off_fin = 802.466 uV 11:45:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 257.297 uVs 11:45:46 Integrated Voltage Measurement... 11:45:54 Voltage Offset Correction: v_off_ini = 767.787 uV, v_off_fin = 762.664 uV 11:45:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.296 uVs 11:45:55 Integrated Voltage Measurement... 11:46:03 Voltage Offset Correction: v_off_ini = 765.366 uV, v_off_fin = 784.620 uV 11:46:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 246.418 uVs 11:46:08 I1Y Average and RMS of Measurements VT = -247.668 +- 11.340 uVs I1Y = -49.528 +- 2.265 uTm 11:46:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:46:15 Integrated Voltage Measurement... 11:46:24 Voltage Offset Correction: v_off_ini = 743.959 uV, v_off_fin = 726.618 uV 11:46:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.481 uVs 11:46:25 Integrated Voltage Measurement... 11:46:34 Voltage Offset Correction: v_off_ini = 758.188 uV, v_off_fin = 757.897 uV 11:46:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.761 uVs 11:46:34 Integrated Voltage Measurement... 11:46:43 Voltage Offset Correction: v_off_ini = 759.283 uV, v_off_fin = 736.490 uV 11:46:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.124 uVs 11:46:43 Integrated Voltage Measurement... 11:46:52 Voltage Offset Correction: v_off_ini = 784.298 uV, v_off_fin = 785.815 uV 11:46:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.217 uVs 11:46:52 Integrated Voltage Measurement... 11:47:01 Voltage Offset Correction: v_off_ini = 794.382 uV, v_off_fin = 767.422 uV 11:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -159.179 uVs 11:47:01 Integrated Voltage Measurement... 11:47:10 Voltage Offset Correction: v_off_ini = 749.987 uV, v_off_fin = 788.539 uV 11:47:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.985 uVs 11:47:12 I2X Average and RMS of Measurements VT = -98.958 +- 20.438 uVs I2X = 9.104 +- 1.880 uTm^2 11:47:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:20 Integrated Voltage Measurement... 11:47:29 Voltage Offset Correction: v_off_ini = 736.659 uV, v_off_fin = 753.653 uV 11:47:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.673 uVs 11:47:29 Integrated Voltage Measurement... 11:47:38 Voltage Offset Correction: v_off_ini = 757.754 uV, v_off_fin = 725.149 uV 11:47:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.853 uVs 11:47:38 Integrated Voltage Measurement... 11:47:47 Voltage Offset Correction: v_off_ini = 730.491 uV, v_off_fin = 723.863 uV 11:47:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.450 uVs 11:47:47 Integrated Voltage Measurement... 11:47:56 Voltage Offset Correction: v_off_ini = 755.342 uV, v_off_fin = 755.195 uV 11:47:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.210 uVs 11:47:56 Integrated Voltage Measurement... 11:48:05 Voltage Offset Correction: v_off_ini = 739.980 uV, v_off_fin = 756.966 uV 11:48:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.417 uVs 11:48:05 Integrated Voltage Measurement... 11:48:14 Voltage Offset Correction: v_off_ini = 737.440 uV, v_off_fin = 708.202 uV 11:48:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.459 uVs 11:48:17 I2Y Average and RMS of Measurements VT = -262.177 +- 24.108 uVs I2Y = -24.120 +- 2.218 uTm^2 11:48:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:34 Integrated Voltage Measurement... 11:48:43 Voltage Offset Correction: v_off_ini = 744.087 uV, v_off_fin = 771.589 uV 11:48:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -119.024 uVs 11:48:43 Integrated Voltage Measurement... 11:48:52 Voltage Offset Correction: v_off_ini = 753.393 uV, v_off_fin = 722.284 uV 11:48:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.614 uVs 11:48:52 Integrated Voltage Measurement... 11:49:01 Voltage Offset Correction: v_off_ini = 720.655 uV, v_off_fin = 707.483 uV 11:49:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.459 uVs 11:49:01 Integrated Voltage Measurement... 11:49:10 Voltage Offset Correction: v_off_ini = 749.293 uV, v_off_fin = 716.206 uV 11:49:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.557 uVs 11:49:10 Integrated Voltage Measurement... 11:49:19 Voltage Offset Correction: v_off_ini = 720.805 uV, v_off_fin = 726.444 uV 11:49:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.936 uVs 11:49:19 Integrated Voltage Measurement... 11:49:28 Voltage Offset Correction: v_off_ini = 709.424 uV, v_off_fin = 714.545 uV 11:49:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.333 uVs 11:49:32 I1X Average and RMS of Measurements VT = -91.487 +- 11.321 uVs I1X = 18.298 +- 2.265 uTm 11:49:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:49:39 Integrated Voltage Measurement... 11:49:48 Voltage Offset Correction: v_off_ini = 753.072 uV, v_off_fin = 741.273 uV 11:49:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.211 uVs 11:49:48 Integrated Voltage Measurement... 11:49:57 Voltage Offset Correction: v_off_ini = 771.194 uV, v_off_fin = 774.070 uV 11:49:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 247.311 uVs 11:49:57 Integrated Voltage Measurement... 11:50:06 Voltage Offset Correction: v_off_ini = 750.511 uV, v_off_fin = 729.823 uV 11:50:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -255.911 uVs 11:50:06 Integrated Voltage Measurement... 11:50:15 Voltage Offset Correction: v_off_ini = 701.981 uV, v_off_fin = 756.557 uV 11:50:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 252.071 uVs 11:50:15 Integrated Voltage Measurement... 11:50:24 Voltage Offset Correction: v_off_ini = 726.529 uV, v_off_fin = 729.051 uV 11:50:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -234.130 uVs 11:50:24 Integrated Voltage Measurement... 11:50:33 Voltage Offset Correction: v_off_ini = 746.756 uV, v_off_fin = 749.646 uV 11:50:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 278.077 uVs 11:50:37 I1Y Average and RMS of Measurements VT = -248.952 +- 8.663 uVs I1Y = -49.784 +- 1.731 uTm 11:50:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:50:45 Integrated Voltage Measurement... 11:50:54 Voltage Offset Correction: v_off_ini = 741.014 uV, v_off_fin = 760.955 uV 11:50:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.248 uVs 11:50:54 Integrated Voltage Measurement... 11:51:03 Voltage Offset Correction: v_off_ini = 745.426 uV, v_off_fin = 766.819 uV 11:51:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.356 uVs 11:51:03 Integrated Voltage Measurement... 11:51:12 Voltage Offset Correction: v_off_ini = 772.481 uV, v_off_fin = 762.212 uV 11:51:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -101.914 uVs 11:51:12 Integrated Voltage Measurement... 11:51:21 Voltage Offset Correction: v_off_ini = 757.886 uV, v_off_fin = 757.402 uV 11:51:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.837 uVs 11:51:21 Integrated Voltage Measurement... 11:51:30 Voltage Offset Correction: v_off_ini = 747.533 uV, v_off_fin = 745.153 uV 11:51:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.731 uVs 11:51:30 Integrated Voltage Measurement... 11:51:39 Voltage Offset Correction: v_off_ini = 764.016 uV, v_off_fin = 732.731 uV 11:51:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.060 uVs 11:51:42 I2X Average and RMS of Measurements VT = -111.858 +- 5.886 uVs I2X = 10.291 +- 0.541 uTm^2 11:51:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:51:50 Integrated Voltage Measurement... 11:51:59 Voltage Offset Correction: v_off_ini = 737.626 uV, v_off_fin = 774.685 uV 11:51:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.909 uVs 11:51:59 Integrated Voltage Measurement... 11:52:08 Voltage Offset Correction: v_off_ini = 759.365 uV, v_off_fin = 746.947 uV 11:52:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.909 uVs 11:52:08 Integrated Voltage Measurement... 11:52:17 Voltage Offset Correction: v_off_ini = 779.393 uV, v_off_fin = 749.844 uV 11:52:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.145 uVs 11:52:17 Integrated Voltage Measurement... 11:52:26 Voltage Offset Correction: v_off_ini = 736.019 uV, v_off_fin = 724.807 uV 11:52:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.267 uVs 11:52:26 Integrated Voltage Measurement... 11:52:35 Voltage Offset Correction: v_off_ini = 757.017 uV, v_off_fin = 726.033 uV 11:52:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.561 uVs 11:52:35 Integrated Voltage Measurement... 11:52:44 Voltage Offset Correction: v_off_ini = 734.747 uV, v_off_fin = 732.166 uV 11:52:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.749 uVs 11:52:46 I2Y Average and RMS of Measurements VT = -272.423 +- 9.169 uVs I2Y = -25.063 +- 0.844 uTm^2 11:52:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:53:04 Integrated Voltage Measurement... 11:53:13 Voltage Offset Correction: v_off_ini = 739.432 uV, v_off_fin = 760.541 uV 11:53:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -69.149 uVs 11:53:13 Integrated Voltage Measurement... 11:53:22 Voltage Offset Correction: v_off_ini = 734.026 uV, v_off_fin = 747.480 uV 11:53:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.281 uVs 11:53:22 Integrated Voltage Measurement... 11:53:31 Voltage Offset Correction: v_off_ini = 727.278 uV, v_off_fin = 753.376 uV 11:53:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.008 uVs 11:53:31 Integrated Voltage Measurement... 11:53:40 Voltage Offset Correction: v_off_ini = 772.268 uV, v_off_fin = 783.510 uV 11:53:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.226 uVs 11:53:40 Integrated Voltage Measurement... 11:53:49 Voltage Offset Correction: v_off_ini = 753.428 uV, v_off_fin = 765.220 uV 11:53:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.400 uVs 11:53:49 Integrated Voltage Measurement... 11:53:58 Voltage Offset Correction: v_off_ini = 735.309 uV, v_off_fin = 728.743 uV 11:53:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.126 uVs 11:54:02 I1X Average and RMS of Measurements VT = -93.865 +- 8.609 uVs I1X = 18.773 +- 1.721 uTm 11:54:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:54:09 Integrated Voltage Measurement... 11:54:18 Voltage Offset Correction: v_off_ini = 777.795 uV, v_off_fin = 752.462 uV 11:54:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.475 uVs 11:54:18 Integrated Voltage Measurement... 11:54:27 Voltage Offset Correction: v_off_ini = 778.738 uV, v_off_fin = 778.591 uV 11:54:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 261.415 uVs 11:54:27 Integrated Voltage Measurement... 11:54:36 Voltage Offset Correction: v_off_ini = 744.879 uV, v_off_fin = 736.708 uV 11:54:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -246.127 uVs 11:54:36 Integrated Voltage Measurement... 11:54:45 Voltage Offset Correction: v_off_ini = 734.794 uV, v_off_fin = 753.414 uV 11:54:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.399 uVs 11:54:45 Integrated Voltage Measurement... 11:54:54 Voltage Offset Correction: v_off_ini = 789.197 uV, v_off_fin = 782.836 uV 11:54:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -271.982 uVs 11:54:54 Integrated Voltage Measurement... 11:55:03 Voltage Offset Correction: v_off_ini = 754.004 uV, v_off_fin = 777.530 uV 11:55:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 277.262 uVs 11:55:07 I1Y Average and RMS of Measurements VT = -254.610 +- 15.704 uVs I1Y = -50.917 +- 3.139 uTm 11:55:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:55:15 Integrated Voltage Measurement... 11:55:24 Voltage Offset Correction: v_off_ini = 771.359 uV, v_off_fin = 747.453 uV 11:55:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.316 uVs 11:55:24 Integrated Voltage Measurement... 11:55:33 Voltage Offset Correction: v_off_ini = 769.968 uV, v_off_fin = 746.849 uV 11:55:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.191 uVs 11:55:33 Integrated Voltage Measurement... 11:55:42 Voltage Offset Correction: v_off_ini = 726.650 uV, v_off_fin = 705.245 uV 11:55:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -125.623 uVs 11:55:42 Integrated Voltage Measurement... 11:55:51 Voltage Offset Correction: v_off_ini = 787.790 uV, v_off_fin = 754.737 uV 11:55:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.950 uVs 11:55:51 Integrated Voltage Measurement... 11:56:00 Voltage Offset Correction: v_off_ini = 773.122 uV, v_off_fin = 744.733 uV 11:56:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -133.399 uVs 11:56:00 Integrated Voltage Measurement... 11:56:09 Voltage Offset Correction: v_off_ini = 756.287 uV, v_off_fin = 780.521 uV 11:56:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.602 uVs 11:56:11 I2X Average and RMS of Measurements VT = -115.513 +- 16.401 uVs I2X = 10.628 +- 1.509 uTm^2 11:56:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:56:19 Integrated Voltage Measurement... 11:56:28 Voltage Offset Correction: v_off_ini = 779.911 uV, v_off_fin = 801.518 uV 11:56:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.034 uVs 11:56:28 Integrated Voltage Measurement... 11:56:37 Voltage Offset Correction: v_off_ini = 788.006 uV, v_off_fin = 833.601 uV 11:56:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.649 uVs 11:56:37 Integrated Voltage Measurement... 11:56:46 Voltage Offset Correction: v_off_ini = 801.225 uV, v_off_fin = 790.951 uV 11:56:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.843 uVs 11:56:46 Integrated Voltage Measurement... 11:56:55 Voltage Offset Correction: v_off_ini = 775.117 uV, v_off_fin = 765.687 uV 11:56:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.487 uVs 11:56:55 Integrated Voltage Measurement... 11:57:04 Voltage Offset Correction: v_off_ini = 806.289 uV, v_off_fin = 797.747 uV 11:57:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.805 uVs 11:57:04 Integrated Voltage Measurement... 11:57:13 Voltage Offset Correction: v_off_ini = 812.037 uV, v_off_fin = 817.606 uV 11:57:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.817 uVs 11:57:16 I2Y Average and RMS of Measurements VT = -282.439 +- 15.792 uVs I2Y = -25.984 +- 1.453 uTm^2 11:57:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm