SLAC Magnetic Measurements Date: 01-07-2025 Time: 09:00:10 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10086 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 2 Measurement Device: On Axis Operator: YL Comment: Shim 0.5mm replaced by shim 0.25mm Parameters: Measurement Type = I12XY VS X VS GAP I1X dy = 0.5000 mm I1Y dx = 0.5000 mm I2X dy = 1.0000 mm I2Y dx = 1.0000 mm Wire # Turns = 1 Preamplifier Gain = 10000.00 Background Field Integrals: I1X = 19.0 (uTm) I1Y = -39.0 (uTm) I2X = 9.0 (uTm2) I2Y = -19.0 (uTm2) Subtracted from results Field Integrals: Gap (mm) X0 (mm) Y0 (mm) I1x (uTm) I1y (uTm) I2x (uTm^2) I2y (uTm^2) ---------- ---------- ---------- ---------------------- ---------------------- ---------------------- ---------------------- 9.995 0.000 0.000 -2.512+- 2.083 32.671+- 1.371 -1.536+- 0.438 10.451+- 0.220