SLAC Magnetic Measurements Date: 01-07-2025 Time: 13:53:08 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10086 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 2 Measurement Device: Good Field Region Operator: YL Comment: Off Axis 13:53:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:18 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:53:19 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:53:21 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:53:23 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:54:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:54:11 Integrated Voltage Measurement... 13:54:20 Voltage Offset Correction: v_off_ini = 691.315 uV, v_off_fin = 684.519 uV 13:54:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -146.453 uVs 13:54:20 Integrated Voltage Measurement... 13:54:29 Voltage Offset Correction: v_off_ini = 695.103 uV, v_off_fin = 685.209 uV 13:54:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.399 uVs 13:54:29 Integrated Voltage Measurement... 13:54:38 Voltage Offset Correction: v_off_ini = 693.315 uV, v_off_fin = 694.169 uV 13:54:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.603 uVs 13:54:38 Integrated Voltage Measurement... 13:54:47 Voltage Offset Correction: v_off_ini = 678.676 uV, v_off_fin = 671.830 uV 13:54:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.190 uVs 13:54:47 Integrated Voltage Measurement... 13:54:56 Voltage Offset Correction: v_off_ini = 659.353 uV, v_off_fin = 675.688 uV 13:54:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.254 uVs 13:54:56 Integrated Voltage Measurement... 13:55:05 Voltage Offset Correction: v_off_ini = 687.084 uV, v_off_fin = 680.600 uV 13:55:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.446 uVs 13:55:09 I1X Average and RMS of Measurements VT = -123.558 +- 9.024 uVs I1X = 24.713 +- 1.806 uTm 13:55:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:55:16 Integrated Voltage Measurement... 13:55:25 Voltage Offset Correction: v_off_ini = 689.927 uV, v_off_fin = 682.295 uV 13:55:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.614 uVs 13:55:25 Integrated Voltage Measurement... 13:55:34 Voltage Offset Correction: v_off_ini = 689.413 uV, v_off_fin = 704.358 uV 13:55:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.235 uVs 13:55:34 Integrated Voltage Measurement... 13:55:43 Voltage Offset Correction: v_off_ini = 701.939 uV, v_off_fin = 683.190 uV 13:55:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.744 uVs 13:55:43 Integrated Voltage Measurement... 13:55:52 Voltage Offset Correction: v_off_ini = 680.075 uV, v_off_fin = 690.545 uV 13:55:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.951 uVs 13:55:52 Integrated Voltage Measurement... 13:56:01 Voltage Offset Correction: v_off_ini = 688.064 uV, v_off_fin = 696.624 uV 13:56:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.958 uVs 13:56:01 Integrated Voltage Measurement... 13:56:10 Voltage Offset Correction: v_off_ini = 695.200 uV, v_off_fin = 702.379 uV 13:56:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.099 uVs 13:56:14 I1Y Average and RMS of Measurements VT = -195.933 +- 5.946 uVs I1Y = -39.187 +- 1.189 uTm 13:56:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:56:22 Integrated Voltage Measurement... 13:56:31 Voltage Offset Correction: v_off_ini = 674.359 uV, v_off_fin = 678.306 uV 13:56:31 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -101.521 uVs 13:56:31 Integrated Voltage Measurement... 13:56:40 Voltage Offset Correction: v_off_ini = 680.473 uV, v_off_fin = 687.227 uV 13:56:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 134.188 uVs 13:56:40 Integrated Voltage Measurement... 13:56:49 Voltage Offset Correction: v_off_ini = 678.279 uV, v_off_fin = 666.621 uV 13:56:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -147.183 uVs 13:56:49 Integrated Voltage Measurement... 13:56:58 Voltage Offset Correction: v_off_ini = 668.644 uV, v_off_fin = 694.163 uV 13:56:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.727 uVs 13:56:58 Integrated Voltage Measurement... 13:57:07 Voltage Offset Correction: v_off_ini = 684.588 uV, v_off_fin = 668.606 uV 13:57:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -117.205 uVs 13:57:07 Integrated Voltage Measurement... 13:57:16 Voltage Offset Correction: v_off_ini = 684.528 uV, v_off_fin = 692.017 uV 13:57:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 122.351 uVs 13:57:18 I2X Average and RMS of Measurements VT = -120.362 +- 2.323 uVs I2X = 11.074 +- 0.214 uTm^2 13:57:24 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:57:26 Integrated Voltage Measurement... 13:57:35 Voltage Offset Correction: v_off_ini = 680.296 uV, v_off_fin = 679.843 uV 13:57:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.128 uVs 13:57:35 Integrated Voltage Measurement... 13:57:44 Voltage Offset Correction: v_off_ini = 683.230 uV, v_off_fin = 694.644 uV 13:57:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.675 uVs 13:57:44 Integrated Voltage Measurement... 13:57:53 Voltage Offset Correction: v_off_ini = 685.849 uV, v_off_fin = 683.036 uV 13:57:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.529 uVs 13:57:53 Integrated Voltage Measurement... 13:58:02 Voltage Offset Correction: v_off_ini = 694.048 uV, v_off_fin = 700.984 uV 13:58:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.847 uVs 13:58:02 Integrated Voltage Measurement... 13:58:11 Voltage Offset Correction: v_off_ini = 687.422 uV, v_off_fin = 698.259 uV 13:58:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.654 uVs 13:58:11 Integrated Voltage Measurement... 13:58:20 Voltage Offset Correction: v_off_ini = 697.177 uV, v_off_fin = 693.670 uV 13:58:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.609 uVs 13:58:23 I2Y Average and RMS of Measurements VT = -287.240 +- 11.588 uVs I2Y = -26.426 +- 1.066 uTm^2 13:58:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:58:32 Integrated Voltage Measurement... 13:58:41 Voltage Offset Correction: v_off_ini = 692.935 uV, v_off_fin = 692.919 uV 13:58:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.249 uVs 13:58:41 Integrated Voltage Measurement... 13:58:50 Voltage Offset Correction: v_off_ini = 681.210 uV, v_off_fin = 684.332 uV 13:58:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.309 uVs 13:58:50 Integrated Voltage Measurement... 13:58:59 Voltage Offset Correction: v_off_ini = 678.839 uV, v_off_fin = 691.702 uV 13:58:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.516 uVs 13:58:59 Integrated Voltage Measurement... 13:59:08 Voltage Offset Correction: v_off_ini = 681.541 uV, v_off_fin = 673.876 uV 13:59:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.399 uVs 13:59:08 Integrated Voltage Measurement... 13:59:17 Voltage Offset Correction: v_off_ini = 674.762 uV, v_off_fin = 687.803 uV 13:59:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.481 uVs 13:59:17 Integrated Voltage Measurement... 13:59:26 Voltage Offset Correction: v_off_ini = 681.000 uV, v_off_fin = 681.073 uV 13:59:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.658 uVs 13:59:30 I1X Average and RMS of Measurements VT = -121.268 +- 1.430 uVs I1X = 24.254 +- 0.286 uTm 13:59:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:59:37 Integrated Voltage Measurement... 13:59:46 Voltage Offset Correction: v_off_ini = 689.651 uV, v_off_fin = 666.301 uV 13:59:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.795 uVs 13:59:46 Integrated Voltage Measurement... 13:59:55 Voltage Offset Correction: v_off_ini = 684.569 uV, v_off_fin = 696.172 uV 13:59:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.596 uVs 13:59:55 Integrated Voltage Measurement... 14:00:04 Voltage Offset Correction: v_off_ini = 671.634 uV, v_off_fin = 673.843 uV 14:00:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.403 uVs 14:00:04 Integrated Voltage Measurement... 14:00:13 Voltage Offset Correction: v_off_ini = 692.271 uV, v_off_fin = 678.099 uV 14:00:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.234 uVs 14:00:13 Integrated Voltage Measurement... 14:00:22 Voltage Offset Correction: v_off_ini = 681.202 uV, v_off_fin = 672.935 uV 14:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.168 uVs 14:00:22 Integrated Voltage Measurement... 14:00:31 Voltage Offset Correction: v_off_ini = 677.954 uV, v_off_fin = 688.834 uV 14:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.529 uVs 14:00:35 I1Y Average and RMS of Measurements VT = -202.954 +- 6.631 uVs I1Y = -40.591 +- 1.326 uTm 14:00:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:00:43 Integrated Voltage Measurement... 14:00:52 Voltage Offset Correction: v_off_ini = 677.495 uV, v_off_fin = 678.363 uV 14:00:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -106.735 uVs 14:00:52 Integrated Voltage Measurement... 14:01:01 Voltage Offset Correction: v_off_ini = 686.524 uV, v_off_fin = 686.338 uV 14:01:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.697 uVs 14:01:01 Integrated Voltage Measurement... 14:01:10 Voltage Offset Correction: v_off_ini = 697.875 uV, v_off_fin = 683.709 uV 14:01:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.891 uVs 14:01:10 Integrated Voltage Measurement... 14:01:19 Voltage Offset Correction: v_off_ini = 686.070 uV, v_off_fin = 678.483 uV 14:01:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.824 uVs 14:01:19 Integrated Voltage Measurement... 14:01:28 Voltage Offset Correction: v_off_ini = 714.662 uV, v_off_fin = 699.977 uV 14:01:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.238 uVs 14:01:28 Integrated Voltage Measurement... 14:01:37 Voltage Offset Correction: v_off_ini = 707.657 uV, v_off_fin = 713.385 uV 14:01:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.185 uVs 14:01:40 I2X Average and RMS of Measurements VT = -120.262 +- 10.581 uVs I2X = 11.064 +- 0.974 uTm^2 14:01:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:01:47 Integrated Voltage Measurement... 14:01:56 Voltage Offset Correction: v_off_ini = 716.207 uV, v_off_fin = 704.439 uV 14:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.670 uVs 14:01:56 Integrated Voltage Measurement... 14:02:05 Voltage Offset Correction: v_off_ini = 711.457 uV, v_off_fin = 718.268 uV 14:02:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.328 uVs 14:02:05 Integrated Voltage Measurement... 14:02:14 Voltage Offset Correction: v_off_ini = 701.737 uV, v_off_fin = 693.274 uV 14:02:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.547 uVs 14:02:15 Integrated Voltage Measurement... 14:02:24 Voltage Offset Correction: v_off_ini = 713.848 uV, v_off_fin = 715.982 uV 14:02:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.186 uVs 14:02:24 Integrated Voltage Measurement... 14:02:33 Voltage Offset Correction: v_off_ini = 685.026 uV, v_off_fin = 694.687 uV 14:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.255 uVs 14:02:33 Integrated Voltage Measurement... 14:02:42 Voltage Offset Correction: v_off_ini = 688.359 uV, v_off_fin = 692.523 uV 14:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.163 uVs 14:02:44 I2Y Average and RMS of Measurements VT = -281.025 +- 8.132 uVs I2Y = -25.854 +- 0.748 uTm^2 14:02:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:53 Integrated Voltage Measurement... 14:03:02 Voltage Offset Correction: v_off_ini = 694.977 uV, v_off_fin = 702.752 uV 14:03:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -123.640 uVs 14:03:02 Integrated Voltage Measurement... 14:03:11 Voltage Offset Correction: v_off_ini = 696.230 uV, v_off_fin = 692.408 uV 14:03:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.458 uVs 14:03:11 Integrated Voltage Measurement... 14:03:20 Voltage Offset Correction: v_off_ini = 675.487 uV, v_off_fin = 704.786 uV 14:03:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.630 uVs 14:03:20 Integrated Voltage Measurement... 14:03:29 Voltage Offset Correction: v_off_ini = 703.491 uV, v_off_fin = 694.427 uV 14:03:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.700 uVs 14:03:29 Integrated Voltage Measurement... 14:03:38 Voltage Offset Correction: v_off_ini = 701.924 uV, v_off_fin = 694.613 uV 14:03:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.419 uVs 14:03:38 Integrated Voltage Measurement... 14:03:47 Voltage Offset Correction: v_off_ini = 688.446 uV, v_off_fin = 691.757 uV 14:03:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.465 uVs 14:03:51 I1X Average and RMS of Measurements VT = -112.885 +- 13.206 uVs I1X = 22.577 +- 2.642 uTm 14:03:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:03:58 Integrated Voltage Measurement... 14:04:07 Voltage Offset Correction: v_off_ini = 696.797 uV, v_off_fin = 685.353 uV 14:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -198.431 uVs 14:04:07 Integrated Voltage Measurement... 14:04:16 Voltage Offset Correction: v_off_ini = 692.027 uV, v_off_fin = 695.238 uV 14:04:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.875 uVs 14:04:16 Integrated Voltage Measurement... 14:04:25 Voltage Offset Correction: v_off_ini = 692.007 uV, v_off_fin = 694.213 uV 14:04:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.971 uVs 14:04:25 Integrated Voltage Measurement... 14:04:34 Voltage Offset Correction: v_off_ini = 692.021 uV, v_off_fin = 713.773 uV 14:04:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.606 uVs 14:04:34 Integrated Voltage Measurement... 14:04:43 Voltage Offset Correction: v_off_ini = 691.255 uV, v_off_fin = 689.959 uV 14:04:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.828 uVs 14:04:43 Integrated Voltage Measurement... 14:04:52 Voltage Offset Correction: v_off_ini = 709.280 uV, v_off_fin = 687.840 uV 14:04:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.966 uVs 14:04:56 I1Y Average and RMS of Measurements VT = -194.113 +- 1.833 uVs I1Y = -38.823 +- 0.367 uTm 14:05:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:04 Integrated Voltage Measurement... 14:05:13 Voltage Offset Correction: v_off_ini = 688.620 uV, v_off_fin = 696.354 uV 14:05:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -100.624 uVs 14:05:13 Integrated Voltage Measurement... 14:05:22 Voltage Offset Correction: v_off_ini = 697.451 uV, v_off_fin = 714.701 uV 14:05:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.796 uVs 14:05:22 Integrated Voltage Measurement... 14:05:31 Voltage Offset Correction: v_off_ini = 679.997 uV, v_off_fin = 674.634 uV 14:05:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.212 uVs 14:05:31 Integrated Voltage Measurement... 14:05:40 Voltage Offset Correction: v_off_ini = 691.029 uV, v_off_fin = 706.700 uV 14:05:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.376 uVs 14:05:40 Integrated Voltage Measurement... 14:05:49 Voltage Offset Correction: v_off_ini = 701.055 uV, v_off_fin = 694.784 uV 14:05:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.807 uVs 14:05:49 Integrated Voltage Measurement... 14:05:58 Voltage Offset Correction: v_off_ini = 691.041 uV, v_off_fin = 711.713 uV 14:05:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.380 uVs 14:06:01 I2X Average and RMS of Measurements VT = -114.699 +- 2.531 uVs I2X = 10.552 +- 0.233 uTm^2 14:06:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:08 Integrated Voltage Measurement... 14:06:17 Voltage Offset Correction: v_off_ini = 712.684 uV, v_off_fin = 718.489 uV 14:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.228 uVs 14:06:18 Integrated Voltage Measurement... 14:06:27 Voltage Offset Correction: v_off_ini = 707.775 uV, v_off_fin = 712.574 uV 14:06:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.090 uVs 14:06:27 Integrated Voltage Measurement... 14:06:36 Voltage Offset Correction: v_off_ini = 708.594 uV, v_off_fin = 701.510 uV 14:06:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.175 uVs 14:06:36 Integrated Voltage Measurement... 14:06:45 Voltage Offset Correction: v_off_ini = 698.951 uV, v_off_fin = 711.750 uV 14:06:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.587 uVs 14:06:45 Integrated Voltage Measurement... 14:06:54 Voltage Offset Correction: v_off_ini = 704.570 uV, v_off_fin = 701.568 uV 14:06:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.308 uVs 14:06:54 Integrated Voltage Measurement... 14:07:03 Voltage Offset Correction: v_off_ini = 697.053 uV, v_off_fin = 677.045 uV 14:07:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.058 uVs 14:07:05 I2Y Average and RMS of Measurements VT = -270.741 +- 11.018 uVs I2Y = -24.908 +- 1.014 uTm^2 14:07:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:07:14 Integrated Voltage Measurement... 14:07:23 Voltage Offset Correction: v_off_ini = 695.059 uV, v_off_fin = 688.910 uV 14:07:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.081 uVs 14:07:23 Integrated Voltage Measurement... 14:07:32 Voltage Offset Correction: v_off_ini = 683.306 uV, v_off_fin = 672.777 uV 14:07:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.846 uVs 14:07:32 Integrated Voltage Measurement... 14:07:41 Voltage Offset Correction: v_off_ini = 671.031 uV, v_off_fin = 680.400 uV 14:07:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.672 uVs 14:07:41 Integrated Voltage Measurement... 14:07:50 Voltage Offset Correction: v_off_ini = 693.317 uV, v_off_fin = 687.215 uV 14:07:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.573 uVs 14:07:50 Integrated Voltage Measurement... 14:07:59 Voltage Offset Correction: v_off_ini = 690.822 uV, v_off_fin = 688.152 uV 14:07:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.110 uVs 14:07:59 Integrated Voltage Measurement... 14:08:08 Voltage Offset Correction: v_off_ini = 702.237 uV, v_off_fin = 710.097 uV 14:08:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.261 uVs 14:08:12 I1X Average and RMS of Measurements VT = -113.924 +- 2.738 uVs I1X = 22.785 +- 0.548 uTm 14:08:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:08:19 Integrated Voltage Measurement... 14:08:28 Voltage Offset Correction: v_off_ini = 716.806 uV, v_off_fin = 688.762 uV 14:08:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.995 uVs 14:08:28 Integrated Voltage Measurement... 14:08:37 Voltage Offset Correction: v_off_ini = 694.939 uV, v_off_fin = 694.839 uV 14:08:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.605 uVs 14:08:37 Integrated Voltage Measurement... 14:08:46 Voltage Offset Correction: v_off_ini = 703.621 uV, v_off_fin = 695.190 uV 14:08:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.797 uVs 14:08:47 Integrated Voltage Measurement... 14:08:55 Voltage Offset Correction: v_off_ini = 716.302 uV, v_off_fin = 717.986 uV 14:08:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.510 uVs 14:08:56 Integrated Voltage Measurement... 14:09:04 Voltage Offset Correction: v_off_ini = 698.026 uV, v_off_fin = 688.598 uV 14:09:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.609 uVs 14:09:04 Integrated Voltage Measurement... 14:09:13 Voltage Offset Correction: v_off_ini = 697.410 uV, v_off_fin = 700.832 uV 14:09:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.762 uVs 14:09:18 I1Y Average and RMS of Measurements VT = -193.046 +- 3.505 uVs I1Y = -38.609 +- 0.701 uTm 14:09:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:09:25 Integrated Voltage Measurement... 14:09:34 Voltage Offset Correction: v_off_ini = 704.959 uV, v_off_fin = 717.604 uV 14:09:34 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -102.776 uVs 14:09:34 Integrated Voltage Measurement... 14:09:43 Voltage Offset Correction: v_off_ini = 707.037 uV, v_off_fin = 711.734 uV 14:09:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.327 uVs 14:09:44 Integrated Voltage Measurement... 14:09:52 Voltage Offset Correction: v_off_ini = 707.944 uV, v_off_fin = 696.988 uV 14:09:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.317 uVs 14:09:53 Integrated Voltage Measurement... 14:10:02 Voltage Offset Correction: v_off_ini = 687.092 uV, v_off_fin = 701.763 uV 14:10:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.063 uVs 14:10:02 Integrated Voltage Measurement... 14:10:11 Voltage Offset Correction: v_off_ini = 684.749 uV, v_off_fin = 674.613 uV 14:10:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.563 uVs 14:10:11 Integrated Voltage Measurement... 14:10:20 Voltage Offset Correction: v_off_ini = 656.544 uV, v_off_fin = 662.888 uV 14:10:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.974 uVs 14:10:22 I2X Average and RMS of Measurements VT = -102.670 +- 5.390 uVs I2X = 9.446 +- 0.496 uTm^2 14:10:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:10:30 Integrated Voltage Measurement... 14:10:39 Voltage Offset Correction: v_off_ini = 683.468 uV, v_off_fin = 686.563 uV 14:10:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.059 uVs 14:10:39 Integrated Voltage Measurement... 14:10:48 Voltage Offset Correction: v_off_ini = 672.489 uV, v_off_fin = 677.469 uV 14:10:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.593 uVs 14:10:48 Integrated Voltage Measurement... 14:10:57 Voltage Offset Correction: v_off_ini = 664.509 uV, v_off_fin = 649.336 uV 14:10:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.446 uVs 14:10:57 Integrated Voltage Measurement... 14:11:06 Voltage Offset Correction: v_off_ini = 666.603 uV, v_off_fin = 679.142 uV 14:11:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.205 uVs 14:11:06 Integrated Voltage Measurement... 14:11:15 Voltage Offset Correction: v_off_ini = 674.577 uV, v_off_fin = 675.372 uV 14:11:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.592 uVs 14:11:15 Integrated Voltage Measurement... 14:11:24 Voltage Offset Correction: v_off_ini = 677.705 uV, v_off_fin = 680.204 uV 14:11:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.363 uVs 14:11:26 I2Y Average and RMS of Measurements VT = -268.210 +- 2.455 uVs I2Y = -24.675 +- 0.226 uTm^2 14:11:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:11:35 Integrated Voltage Measurement... 14:11:44 Voltage Offset Correction: v_off_ini = 690.963 uV, v_off_fin = 665.072 uV 14:11:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.804 uVs 14:11:44 Integrated Voltage Measurement... 14:11:53 Voltage Offset Correction: v_off_ini = 682.917 uV, v_off_fin = 694.342 uV 14:11:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.587 uVs 14:11:53 Integrated Voltage Measurement... 14:12:02 Voltage Offset Correction: v_off_ini = 682.545 uV, v_off_fin = 677.675 uV 14:12:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.865 uVs 14:12:02 Integrated Voltage Measurement... 14:12:11 Voltage Offset Correction: v_off_ini = 682.598 uV, v_off_fin = 672.243 uV 14:12:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.423 uVs 14:12:11 Integrated Voltage Measurement... 14:12:20 Voltage Offset Correction: v_off_ini = 686.012 uV, v_off_fin = 706.523 uV 14:12:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.963 uVs 14:12:21 Integrated Voltage Measurement... 14:12:29 Voltage Offset Correction: v_off_ini = 703.036 uV, v_off_fin = 690.816 uV 14:12:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.080 uVs 14:12:34 I1X Average and RMS of Measurements VT = -102.787 +- 12.308 uVs I1X = 20.557 +- 2.462 uTm 14:12:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:12:41 Integrated Voltage Measurement... 14:12:49 Voltage Offset Correction: v_off_ini = 692.271 uV, v_off_fin = 691.366 uV 14:12:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.237 uVs 14:12:50 Integrated Voltage Measurement... 14:12:58 Voltage Offset Correction: v_off_ini = 710.403 uV, v_off_fin = 711.702 uV 14:12:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.935 uVs 14:12:59 Integrated Voltage Measurement... 14:13:07 Voltage Offset Correction: v_off_ini = 719.800 uV, v_off_fin = 701.675 uV 14:13:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.371 uVs 14:13:08 Integrated Voltage Measurement... 14:13:16 Voltage Offset Correction: v_off_ini = 723.271 uV, v_off_fin = 716.046 uV 14:13:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.749 uVs 14:13:17 Integrated Voltage Measurement... 14:13:25 Voltage Offset Correction: v_off_ini = 710.105 uV, v_off_fin = 717.190 uV 14:13:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.737 uVs 14:13:26 Integrated Voltage Measurement... 14:13:34 Voltage Offset Correction: v_off_ini = 742.919 uV, v_off_fin = 728.273 uV 14:13:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.293 uVs 14:13:39 I1Y Average and RMS of Measurements VT = -178.554 +- 6.599 uVs I1Y = -35.711 +- 1.320 uTm 14:13:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:13:46 Integrated Voltage Measurement... 14:13:55 Voltage Offset Correction: v_off_ini = 727.115 uV, v_off_fin = 706.677 uV 14:13:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -132.182 uVs 14:13:55 Integrated Voltage Measurement... 14:14:04 Voltage Offset Correction: v_off_ini = 710.612 uV, v_off_fin = 715.118 uV 14:14:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.348 uVs 14:14:05 Integrated Voltage Measurement... 14:14:14 Voltage Offset Correction: v_off_ini = 705.111 uV, v_off_fin = 684.395 uV 14:14:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -121.274 uVs 14:14:14 Integrated Voltage Measurement... 14:14:23 Voltage Offset Correction: v_off_ini = 715.614 uV, v_off_fin = 708.811 uV 14:14:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.056 uVs 14:14:23 Integrated Voltage Measurement... 14:14:32 Voltage Offset Correction: v_off_ini = 704.210 uV, v_off_fin = 701.141 uV 14:14:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.199 uVs 14:14:32 Integrated Voltage Measurement... 14:14:41 Voltage Offset Correction: v_off_ini = 704.913 uV, v_off_fin = 711.468 uV 14:14:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.118 uVs 14:14:43 I2X Average and RMS of Measurements VT = -114.696 +- 8.194 uVs I2X = 10.552 +- 0.754 uTm^2 14:14:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:14:51 Integrated Voltage Measurement... 14:15:00 Voltage Offset Correction: v_off_ini = 718.228 uV, v_off_fin = 714.232 uV 14:15:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.392 uVs 14:15:00 Integrated Voltage Measurement... 14:15:09 Voltage Offset Correction: v_off_ini = 703.519 uV, v_off_fin = 697.748 uV 14:15:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.520 uVs 14:15:09 Integrated Voltage Measurement... 14:15:18 Voltage Offset Correction: v_off_ini = 702.159 uV, v_off_fin = 706.143 uV 14:15:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.911 uVs 14:15:18 Integrated Voltage Measurement... 14:15:27 Voltage Offset Correction: v_off_ini = 729.026 uV, v_off_fin = 721.269 uV 14:15:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.567 uVs 14:15:27 Integrated Voltage Measurement... 14:15:36 Voltage Offset Correction: v_off_ini = 707.709 uV, v_off_fin = 701.332 uV 14:15:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.724 uVs 14:15:36 Integrated Voltage Measurement... 14:15:45 Voltage Offset Correction: v_off_ini = 698.153 uV, v_off_fin = 688.263 uV 14:15:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.455 uVs 14:15:47 I2Y Average and RMS of Measurements VT = -250.595 +- 5.899 uVs I2Y = -23.055 +- 0.543 uTm^2 14:15:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:15:59 Integrated Voltage Measurement... 14:16:08 Voltage Offset Correction: v_off_ini = 680.180 uV, v_off_fin = 685.736 uV 14:16:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -113.323 uVs 14:16:08 Integrated Voltage Measurement... 14:16:17 Voltage Offset Correction: v_off_ini = 649.220 uV, v_off_fin = 670.660 uV 14:16:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.557 uVs 14:16:17 Integrated Voltage Measurement... 14:16:26 Voltage Offset Correction: v_off_ini = 664.205 uV, v_off_fin = 678.224 uV 14:16:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.239 uVs 14:16:26 Integrated Voltage Measurement... 14:16:35 Voltage Offset Correction: v_off_ini = 670.929 uV, v_off_fin = 683.604 uV 14:16:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.894 uVs 14:16:36 Integrated Voltage Measurement... 14:16:44 Voltage Offset Correction: v_off_ini = 669.846 uV, v_off_fin = 669.579 uV 14:16:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.688 uVs 14:16:45 Integrated Voltage Measurement... 14:16:54 Voltage Offset Correction: v_off_ini = 677.256 uV, v_off_fin = 678.593 uV 14:16:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.694 uVs 14:16:58 I1X Average and RMS of Measurements VT = -103.399 +- 11.799 uVs I1X = 20.680 +- 2.360 uTm 14:17:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:17:05 Integrated Voltage Measurement... 14:17:13 Voltage Offset Correction: v_off_ini = 654.219 uV, v_off_fin = 651.988 uV 14:17:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.961 uVs 14:17:14 Integrated Voltage Measurement... 14:17:22 Voltage Offset Correction: v_off_ini = 651.222 uV, v_off_fin = 653.877 uV 14:17:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.568 uVs 14:17:23 Integrated Voltage Measurement... 14:17:32 Voltage Offset Correction: v_off_ini = 648.615 uV, v_off_fin = 658.390 uV 14:17:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.105 uVs 14:17:32 Integrated Voltage Measurement... 14:17:41 Voltage Offset Correction: v_off_ini = 656.123 uV, v_off_fin = 660.700 uV 14:17:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.902 uVs 14:17:41 Integrated Voltage Measurement... 14:17:50 Voltage Offset Correction: v_off_ini = 658.730 uV, v_off_fin = 648.958 uV 14:17:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.289 uVs 14:17:50 Integrated Voltage Measurement... 14:17:59 Voltage Offset Correction: v_off_ini = 642.944 uV, v_off_fin = 651.969 uV 14:17:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.554 uVs 14:18:03 I1Y Average and RMS of Measurements VT = -214.397 +- 4.607 uVs I1Y = -42.879 +- 0.921 uTm 14:18:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:18:08 Integrated Voltage Measurement... 14:18:17 Voltage Offset Correction: v_off_ini = 635.177 uV, v_off_fin = 641.010 uV 14:18:17 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -102.304 uVs 14:18:17 Integrated Voltage Measurement... 14:18:26 Voltage Offset Correction: v_off_ini = 631.332 uV, v_off_fin = 632.624 uV 14:18:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.972 uVs 14:18:26 Integrated Voltage Measurement... 14:18:35 Voltage Offset Correction: v_off_ini = 632.091 uV, v_off_fin = 633.674 uV 14:18:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.711 uVs 14:18:35 Integrated Voltage Measurement... 14:18:44 Voltage Offset Correction: v_off_ini = 625.703 uV, v_off_fin = 633.284 uV 14:18:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.964 uVs 14:18:44 Integrated Voltage Measurement... 14:18:53 Voltage Offset Correction: v_off_ini = 614.961 uV, v_off_fin = 615.876 uV 14:18:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.327 uVs 14:18:53 Integrated Voltage Measurement... 14:19:02 Voltage Offset Correction: v_off_ini = 618.692 uV, v_off_fin = 632.166 uV 14:19:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.517 uVs 14:19:05 I2X Average and RMS of Measurements VT = -112.132 +- 4.889 uVs I2X = 10.316 +- 0.450 uTm^2 14:19:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:19:10 Integrated Voltage Measurement... 14:19:19 Voltage Offset Correction: v_off_ini = 633.333 uV, v_off_fin = 632.687 uV 14:19:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.582 uVs 14:19:19 Integrated Voltage Measurement... 14:19:28 Voltage Offset Correction: v_off_ini = 596.421 uV, v_off_fin = 603.851 uV 14:19:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.724 uVs 14:19:28 Integrated Voltage Measurement... 14:19:37 Voltage Offset Correction: v_off_ini = 619.148 uV, v_off_fin = 639.556 uV 14:19:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.956 uVs 14:19:37 Integrated Voltage Measurement... 14:19:46 Voltage Offset Correction: v_off_ini = 631.433 uV, v_off_fin = 623.401 uV 14:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.551 uVs 14:19:46 Integrated Voltage Measurement... 14:19:55 Voltage Offset Correction: v_off_ini = 599.100 uV, v_off_fin = 620.655 uV 14:19:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.534 uVs 14:19:55 Integrated Voltage Measurement... 14:20:04 Voltage Offset Correction: v_off_ini = 604.837 uV, v_off_fin = 603.188 uV 14:20:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.358 uVs 14:20:06 I2Y Average and RMS of Measurements VT = -289.284 +- 10.183 uVs I2Y = -26.614 +- 0.937 uTm^2 14:20:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:20:15 Integrated Voltage Measurement... 14:20:24 Voltage Offset Correction: v_off_ini = 618.149 uV, v_off_fin = 627.288 uV 14:20:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.286 uVs 14:20:24 Integrated Voltage Measurement... 14:20:33 Voltage Offset Correction: v_off_ini = 622.835 uV, v_off_fin = 622.946 uV 14:20:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.446 uVs 14:20:33 Integrated Voltage Measurement... 14:20:42 Voltage Offset Correction: v_off_ini = 616.630 uV, v_off_fin = 629.109 uV 14:20:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.583 uVs 14:20:42 Integrated Voltage Measurement... 14:20:51 Voltage Offset Correction: v_off_ini = 606.150 uV, v_off_fin = 604.786 uV 14:20:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.822 uVs 14:20:51 Integrated Voltage Measurement... 14:21:00 Voltage Offset Correction: v_off_ini = 621.001 uV, v_off_fin = 632.119 uV 14:21:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.230 uVs 14:21:00 Integrated Voltage Measurement... 14:21:09 Voltage Offset Correction: v_off_ini = 625.652 uV, v_off_fin = 630.882 uV 14:21:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.376 uVs 14:21:13 I1X Average and RMS of Measurements VT = -113.957 +- 9.981 uVs I1X = 22.791 +- 1.996 uTm 14:21:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:21:20 Integrated Voltage Measurement... 14:21:29 Voltage Offset Correction: v_off_ini = 622.476 uV, v_off_fin = 610.689 uV 14:21:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.336 uVs 14:21:29 Integrated Voltage Measurement... 14:21:38 Voltage Offset Correction: v_off_ini = 620.339 uV, v_off_fin = 646.122 uV 14:21:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.398 uVs 14:21:38 Integrated Voltage Measurement... 14:21:47 Voltage Offset Correction: v_off_ini = 605.251 uV, v_off_fin = 615.081 uV 14:21:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.215 uVs 14:21:47 Integrated Voltage Measurement... 14:21:56 Voltage Offset Correction: v_off_ini = 634.576 uV, v_off_fin = 625.074 uV 14:21:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.909 uVs 14:21:56 Integrated Voltage Measurement... 14:22:05 Voltage Offset Correction: v_off_ini = 620.591 uV, v_off_fin = 613.573 uV 14:22:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.864 uVs 14:22:05 Integrated Voltage Measurement... 14:22:14 Voltage Offset Correction: v_off_ini = 627.943 uV, v_off_fin = 631.852 uV 14:22:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.437 uVs 14:22:18 I1Y Average and RMS of Measurements VT = -201.193 +- 7.046 uVs I1Y = -40.239 +- 1.409 uTm 14:22:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:22:23 Integrated Voltage Measurement... 14:22:32 Voltage Offset Correction: v_off_ini = 648.190 uV, v_off_fin = 657.768 uV 14:22:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.253 uVs 14:22:32 Integrated Voltage Measurement... 14:22:41 Voltage Offset Correction: v_off_ini = 664.861 uV, v_off_fin = 655.228 uV 14:22:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.842 uVs 14:22:41 Integrated Voltage Measurement... 14:22:50 Voltage Offset Correction: v_off_ini = 644.627 uV, v_off_fin = 624.933 uV 14:22:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.623 uVs 14:22:50 Integrated Voltage Measurement... 14:22:59 Voltage Offset Correction: v_off_ini = 646.291 uV, v_off_fin = 658.641 uV 14:22:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.329 uVs 14:22:59 Integrated Voltage Measurement... 14:23:08 Voltage Offset Correction: v_off_ini = 673.227 uV, v_off_fin = 662.590 uV 14:23:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.350 uVs 14:23:08 Integrated Voltage Measurement... 14:23:17 Voltage Offset Correction: v_off_ini = 657.110 uV, v_off_fin = 644.794 uV 14:23:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.900 uVs 14:23:19 I2X Average and RMS of Measurements VT = -133.383 +- 5.126 uVs I2X = 12.271 +- 0.472 uTm^2 14:23:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:23:25 Integrated Voltage Measurement... 14:23:34 Voltage Offset Correction: v_off_ini = 687.281 uV, v_off_fin = 688.991 uV 14:23:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.158 uVs 14:23:34 Integrated Voltage Measurement... 14:23:43 Voltage Offset Correction: v_off_ini = 689.592 uV, v_off_fin = 674.296 uV 14:23:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.418 uVs 14:23:43 Integrated Voltage Measurement... 14:23:52 Voltage Offset Correction: v_off_ini = 660.918 uV, v_off_fin = 662.069 uV 14:23:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.761 uVs 14:23:52 Integrated Voltage Measurement... 14:24:01 Voltage Offset Correction: v_off_ini = 671.952 uV, v_off_fin = 662.939 uV 14:24:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.758 uVs 14:24:01 Integrated Voltage Measurement... 14:24:10 Voltage Offset Correction: v_off_ini = 674.714 uV, v_off_fin = 667.453 uV 14:24:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.022 uVs 14:24:10 Integrated Voltage Measurement... 14:24:19 Voltage Offset Correction: v_off_ini = 673.636 uV, v_off_fin = 652.024 uV 14:24:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.716 uVs 14:24:21 I2Y Average and RMS of Measurements VT = -279.639 +- 4.456 uVs I2Y = -25.727 +- 0.410 uTm^2 14:24:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:24:29 Integrated Voltage Measurement... 14:24:38 Voltage Offset Correction: v_off_ini = 674.479 uV, v_off_fin = 671.966 uV 14:24:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.571 uVs 14:24:38 Integrated Voltage Measurement... 14:24:47 Voltage Offset Correction: v_off_ini = 665.119 uV, v_off_fin = 669.714 uV 14:24:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.465 uVs 14:24:47 Integrated Voltage Measurement... 14:24:56 Voltage Offset Correction: v_off_ini = 686.164 uV, v_off_fin = 697.740 uV 14:24:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.915 uVs 14:24:56 Integrated Voltage Measurement... 14:25:05 Voltage Offset Correction: v_off_ini = 711.395 uV, v_off_fin = 702.543 uV 14:25:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.805 uVs 14:25:05 Integrated Voltage Measurement... 14:25:14 Voltage Offset Correction: v_off_ini = 698.036 uV, v_off_fin = 679.977 uV 14:25:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.621 uVs 14:25:14 Integrated Voltage Measurement... 14:25:23 Voltage Offset Correction: v_off_ini = 728.248 uV, v_off_fin = 731.467 uV 14:25:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.922 uVs 14:25:28 I1X Average and RMS of Measurements VT = -104.383 +- 7.884 uVs I1X = 20.877 +- 1.577 uTm 14:25:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:25:34 Integrated Voltage Measurement... 14:25:43 Voltage Offset Correction: v_off_ini = 715.806 uV, v_off_fin = 705.254 uV 14:25:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -180.765 uVs 14:25:43 Integrated Voltage Measurement... 14:25:52 Voltage Offset Correction: v_off_ini = 722.805 uV, v_off_fin = 723.131 uV 14:25:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.650 uVs 14:25:52 Integrated Voltage Measurement... 14:26:01 Voltage Offset Correction: v_off_ini = 726.103 uV, v_off_fin = 720.589 uV 14:26:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.304 uVs 14:26:01 Integrated Voltage Measurement... 14:26:10 Voltage Offset Correction: v_off_ini = 713.563 uV, v_off_fin = 729.670 uV 14:26:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.788 uVs 14:26:10 Integrated Voltage Measurement... 14:26:19 Voltage Offset Correction: v_off_ini = 724.597 uV, v_off_fin = 725.997 uV 14:26:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.392 uVs 14:26:19 Integrated Voltage Measurement... 14:26:28 Voltage Offset Correction: v_off_ini = 719.088 uV, v_off_fin = 750.507 uV 14:26:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 204.951 uVs 14:26:32 I1Y Average and RMS of Measurements VT = -189.308 +- 5.394 uVs I1Y = -37.861 +- 1.077 uTm 14:26:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:37 Integrated Voltage Measurement... 14:26:46 Voltage Offset Correction: v_off_ini = 688.561 uV, v_off_fin = 690.621 uV 14:26:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.669 uVs 14:26:46 Integrated Voltage Measurement... 14:26:55 Voltage Offset Correction: v_off_ini = 696.971 uV, v_off_fin = 707.739 uV 14:26:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.697 uVs 14:26:56 Integrated Voltage Measurement... 14:27:04 Voltage Offset Correction: v_off_ini = 711.154 uV, v_off_fin = 691.073 uV 14:27:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.021 uVs 14:27:05 Integrated Voltage Measurement... 14:27:13 Voltage Offset Correction: v_off_ini = 701.215 uV, v_off_fin = 693.066 uV 14:27:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.652 uVs 14:27:14 Integrated Voltage Measurement... 14:27:23 Voltage Offset Correction: v_off_ini = 694.420 uV, v_off_fin = 692.369 uV 14:27:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.445 uVs 14:27:23 Integrated Voltage Measurement... 14:27:32 Voltage Offset Correction: v_off_ini = 705.753 uV, v_off_fin = 688.575 uV 14:27:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.624 uVs 14:27:34 I2X Average and RMS of Measurements VT = -120.185 +- 15.212 uVs I2X = 11.057 +- 1.400 uTm^2 14:27:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:27:39 Integrated Voltage Measurement... 14:27:48 Voltage Offset Correction: v_off_ini = 698.721 uV, v_off_fin = 670.821 uV 14:27:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0001 mm dXY = 1.0000 mm VT = -280.170 uVs 14:27:48 Integrated Voltage Measurement... 14:27:57 Voltage Offset Correction: v_off_ini = 689.431 uV, v_off_fin = 686.780 uV 14:27:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 281.374 uVs 14:27:57 Integrated Voltage Measurement... 14:28:06 Voltage Offset Correction: v_off_ini = 677.191 uV, v_off_fin = 695.446 uV 14:28:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.560 uVs 14:28:06 Integrated Voltage Measurement... 14:28:15 Voltage Offset Correction: v_off_ini = 690.106 uV, v_off_fin = 691.694 uV 14:28:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.475 uVs 14:28:15 Integrated Voltage Measurement... 14:28:24 Voltage Offset Correction: v_off_ini = 705.386 uV, v_off_fin = 688.011 uV 14:28:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.632 uVs 14:28:24 Integrated Voltage Measurement... 14:28:33 Voltage Offset Correction: v_off_ini = 696.877 uV, v_off_fin = 689.203 uV 14:28:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.844 uVs 14:28:36 I2Y Average and RMS of Measurements VT = -275.842 +- 5.920 uVs I2Y = -25.378 +- 0.545 uTm^2 14:28:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:28:44 Integrated Voltage Measurement... 14:28:53 Voltage Offset Correction: v_off_ini = 699.958 uV, v_off_fin = 699.492 uV 14:28:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.910 uVs 14:28:53 Integrated Voltage Measurement... 14:29:02 Voltage Offset Correction: v_off_ini = 720.745 uV, v_off_fin = 708.582 uV 14:29:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.817 uVs 14:29:02 Integrated Voltage Measurement... 14:29:11 Voltage Offset Correction: v_off_ini = 721.682 uV, v_off_fin = 699.739 uV 14:29:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.375 uVs 14:29:11 Integrated Voltage Measurement... 14:29:20 Voltage Offset Correction: v_off_ini = 689.278 uV, v_off_fin = 701.236 uV 14:29:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.173 uVs 14:29:20 Integrated Voltage Measurement... 14:29:29 Voltage Offset Correction: v_off_ini = 710.949 uV, v_off_fin = 698.275 uV 14:29:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.468 uVs 14:29:29 Integrated Voltage Measurement... 14:29:38 Voltage Offset Correction: v_off_ini = 706.573 uV, v_off_fin = 707.970 uV 14:29:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.651 uVs 14:29:42 I1X Average and RMS of Measurements VT = -104.399 +- 5.282 uVs I1X = 20.880 +- 1.057 uTm 14:29:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:29:49 Integrated Voltage Measurement... 14:29:58 Voltage Offset Correction: v_off_ini = 733.128 uV, v_off_fin = 730.614 uV 14:29:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.855 uVs 14:29:58 Integrated Voltage Measurement... 14:30:07 Voltage Offset Correction: v_off_ini = 724.446 uV, v_off_fin = 723.814 uV 14:30:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.624 uVs 14:30:07 Integrated Voltage Measurement... 14:30:16 Voltage Offset Correction: v_off_ini = 711.198 uV, v_off_fin = 718.971 uV 14:30:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -192.660 uVs 14:30:16 Integrated Voltage Measurement... 14:30:25 Voltage Offset Correction: v_off_ini = 721.124 uV, v_off_fin = 755.148 uV 14:30:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 211.605 uVs 14:30:25 Integrated Voltage Measurement... 14:30:34 Voltage Offset Correction: v_off_ini = 719.688 uV, v_off_fin = 712.146 uV 14:30:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.819 uVs 14:30:34 Integrated Voltage Measurement... 14:30:42 Voltage Offset Correction: v_off_ini = 723.728 uV, v_off_fin = 742.144 uV 14:30:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 164.304 uVs 14:30:47 I1Y Average and RMS of Measurements VT = -188.644 +- 15.101 uVs I1Y = -37.724 +- 3.020 uTm 14:30:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:30:52 Integrated Voltage Measurement... 14:31:01 Voltage Offset Correction: v_off_ini = 706.822 uV, v_off_fin = 704.250 uV 14:31:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.857 uVs 14:31:01 Integrated Voltage Measurement... 14:31:10 Voltage Offset Correction: v_off_ini = 703.358 uV, v_off_fin = 713.110 uV 14:31:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.680 uVs 14:31:10 Integrated Voltage Measurement... 14:31:19 Voltage Offset Correction: v_off_ini = 722.127 uV, v_off_fin = 692.781 uV 14:31:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.153 uVs 14:31:19 Integrated Voltage Measurement... 14:31:28 Voltage Offset Correction: v_off_ini = 715.193 uV, v_off_fin = 709.883 uV 14:31:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.674 uVs 14:31:28 Integrated Voltage Measurement... 14:31:37 Voltage Offset Correction: v_off_ini = 710.037 uV, v_off_fin = 711.703 uV 14:31:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.418 uVs 14:31:37 Integrated Voltage Measurement... 14:31:46 Voltage Offset Correction: v_off_ini = 692.301 uV, v_off_fin = 699.899 uV 14:31:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.197 uVs 14:31:48 I2X Average and RMS of Measurements VT = -124.496 +- 5.108 uVs I2X = 11.454 +- 0.470 uTm^2 14:31:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:31:53 Integrated Voltage Measurement... 14:32:02 Voltage Offset Correction: v_off_ini = 718.458 uV, v_off_fin = 695.869 uV 14:32:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.047 uVs 14:32:02 Integrated Voltage Measurement... 14:32:11 Voltage Offset Correction: v_off_ini = 702.746 uV, v_off_fin = 701.560 uV 14:32:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.828 uVs 14:32:11 Integrated Voltage Measurement... 14:32:20 Voltage Offset Correction: v_off_ini = 710.956 uV, v_off_fin = 713.959 uV 14:32:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.158 uVs 14:32:20 Integrated Voltage Measurement... 14:32:29 Voltage Offset Correction: v_off_ini = 720.329 uV, v_off_fin = 729.203 uV 14:32:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.186 uVs 14:32:29 Integrated Voltage Measurement... 14:32:38 Voltage Offset Correction: v_off_ini = 728.537 uV, v_off_fin = 697.453 uV 14:32:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.195 uVs 14:32:38 Integrated Voltage Measurement... 14:32:47 Voltage Offset Correction: v_off_ini = 713.836 uV, v_off_fin = 717.400 uV 14:32:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.593 uVs 14:32:50 I2Y Average and RMS of Measurements VT = -274.001 +- 7.445 uVs I2Y = -25.208 +- 0.685 uTm^2 14:32:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:32:58 Integrated Voltage Measurement... 14:33:07 Voltage Offset Correction: v_off_ini = 742.120 uV, v_off_fin = 739.363 uV 14:33:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -131.161 uVs 14:33:07 Integrated Voltage Measurement... 14:33:16 Voltage Offset Correction: v_off_ini = 743.121 uV, v_off_fin = 738.363 uV 14:33:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.682 uVs 14:33:16 Integrated Voltage Measurement... 14:33:25 Voltage Offset Correction: v_off_ini = 732.855 uV, v_off_fin = 724.417 uV 14:33:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.112 uVs 14:33:25 Integrated Voltage Measurement... 14:33:34 Voltage Offset Correction: v_off_ini = 722.638 uV, v_off_fin = 727.604 uV 14:33:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.127 uVs 14:33:34 Integrated Voltage Measurement... 14:33:43 Voltage Offset Correction: v_off_ini = 719.150 uV, v_off_fin = 757.659 uV 14:33:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.922 uVs 14:33:43 Integrated Voltage Measurement... 14:33:52 Voltage Offset Correction: v_off_ini = 734.430 uV, v_off_fin = 723.072 uV 14:33:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.677 uVs 14:33:56 I1X Average and RMS of Measurements VT = -114.780 +- 10.755 uVs I1X = 22.956 +- 2.151 uTm 14:33:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:34:03 Integrated Voltage Measurement... 14:34:12 Voltage Offset Correction: v_off_ini = 727.428 uV, v_off_fin = 733.232 uV 14:34:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.363 uVs 14:34:12 Integrated Voltage Measurement... 14:34:21 Voltage Offset Correction: v_off_ini = 747.153 uV, v_off_fin = 753.491 uV 14:34:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 176.180 uVs 14:34:21 Integrated Voltage Measurement... 14:34:30 Voltage Offset Correction: v_off_ini = 734.855 uV, v_off_fin = 715.529 uV 14:34:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.421 uVs 14:34:30 Integrated Voltage Measurement... 14:34:39 Voltage Offset Correction: v_off_ini = 735.694 uV, v_off_fin = 751.246 uV 14:34:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.767 uVs 14:34:39 Integrated Voltage Measurement... 14:34:48 Voltage Offset Correction: v_off_ini = 745.226 uV, v_off_fin = 726.583 uV 14:34:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.967 uVs 14:34:48 Integrated Voltage Measurement... 14:34:57 Voltage Offset Correction: v_off_ini = 756.056 uV, v_off_fin = 750.451 uV 14:34:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.074 uVs 14:35:01 I1Y Average and RMS of Measurements VT = -184.295 +- 0.991 uVs I1Y = -36.857 +- 0.200 uTm 14:35:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:35:06 Integrated Voltage Measurement... 14:35:15 Voltage Offset Correction: v_off_ini = 728.483 uV, v_off_fin = 743.356 uV 14:35:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.473 uVs 14:35:15 Integrated Voltage Measurement... 14:35:24 Voltage Offset Correction: v_off_ini = 734.033 uV, v_off_fin = 750.685 uV 14:35:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.082 uVs 14:35:24 Integrated Voltage Measurement... 14:35:33 Voltage Offset Correction: v_off_ini = 753.720 uV, v_off_fin = 741.298 uV 14:35:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.302 uVs 14:35:33 Integrated Voltage Measurement... 14:35:42 Voltage Offset Correction: v_off_ini = 727.648 uV, v_off_fin = 732.463 uV 14:35:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.654 uVs 14:35:42 Integrated Voltage Measurement... 14:35:51 Voltage Offset Correction: v_off_ini = 756.439 uV, v_off_fin = 744.380 uV 14:35:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.283 uVs 14:35:51 Integrated Voltage Measurement... 14:36:00 Voltage Offset Correction: v_off_ini = 766.414 uV, v_off_fin = 745.558 uV 14:36:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.363 uVs 14:36:03 I2X Average and RMS of Measurements VT = -124.859 +- 13.142 uVs I2X = 11.487 +- 1.209 uTm^2 14:36:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:36:08 Integrated Voltage Measurement... 14:36:17 Voltage Offset Correction: v_off_ini = 777.900 uV, v_off_fin = 783.860 uV 14:36:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.902 uVs 14:36:17 Integrated Voltage Measurement... 14:36:26 Voltage Offset Correction: v_off_ini = 757.107 uV, v_off_fin = 769.522 uV 14:36:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.360 uVs 14:36:26 Integrated Voltage Measurement... 14:36:35 Voltage Offset Correction: v_off_ini = 781.882 uV, v_off_fin = 781.528 uV 14:36:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.965 uVs 14:36:35 Integrated Voltage Measurement... 14:36:44 Voltage Offset Correction: v_off_ini = 759.641 uV, v_off_fin = 761.196 uV 14:36:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.389 uVs 14:36:44 Integrated Voltage Measurement... 14:36:53 Voltage Offset Correction: v_off_ini = 770.596 uV, v_off_fin = 759.346 uV 14:36:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.287 uVs 14:36:53 Integrated Voltage Measurement... 14:37:02 Voltage Offset Correction: v_off_ini = 770.123 uV, v_off_fin = 779.367 uV 14:37:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.206 uVs 14:37:04 I2Y Average and RMS of Measurements VT = -277.852 +- 11.853 uVs I2Y = -25.562 +- 1.090 uTm^2 14:37:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:37:23 Integrated Voltage Measurement... 14:37:32 Voltage Offset Correction: v_off_ini = 781.265 uV, v_off_fin = 751.210 uV 14:37:32 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4997 mm dXY = -0.4997 mm VT = -129.207 uVs 14:37:32 Integrated Voltage Measurement... 14:37:41 Voltage Offset Correction: v_off_ini = 765.011 uV, v_off_fin = 755.758 uV 14:37:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 88.913 uVs 14:37:41 Integrated Voltage Measurement... 14:37:50 Voltage Offset Correction: v_off_ini = 769.731 uV, v_off_fin = 770.129 uV 14:37:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.737 uVs 14:37:51 Integrated Voltage Measurement... 14:37:59 Voltage Offset Correction: v_off_ini = 779.968 uV, v_off_fin = 762.535 uV 14:38:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 117.199 uVs 14:38:00 Integrated Voltage Measurement... 14:38:09 Voltage Offset Correction: v_off_ini = 759.403 uV, v_off_fin = 763.348 uV 14:38:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.017 uVs 14:38:09 Integrated Voltage Measurement... 14:38:18 Voltage Offset Correction: v_off_ini = 785.413 uV, v_off_fin = 772.558 uV 14:38:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.053 uVs 14:38:22 I1X Average and RMS of Measurements VT = -104.021 +- 13.121 uVs I1X = 20.808 +- 2.626 uTm 14:38:24 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:38:29 Integrated Voltage Measurement... 14:38:38 Voltage Offset Correction: v_off_ini = 741.726 uV, v_off_fin = 745.520 uV 14:38:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.169 uVs 14:38:38 Integrated Voltage Measurement... 14:38:47 Voltage Offset Correction: v_off_ini = 757.356 uV, v_off_fin = 775.877 uV 14:38:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.403 uVs 14:38:47 Integrated Voltage Measurement... 14:38:56 Voltage Offset Correction: v_off_ini = 763.453 uV, v_off_fin = 766.687 uV 14:38:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.909 uVs 14:38:56 Integrated Voltage Measurement... 14:39:05 Voltage Offset Correction: v_off_ini = 760.593 uV, v_off_fin = 780.754 uV 14:39:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.030 uVs 14:39:05 Integrated Voltage Measurement... 14:39:14 Voltage Offset Correction: v_off_ini = 766.862 uV, v_off_fin = 767.230 uV 14:39:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.430 uVs 14:39:14 Integrated Voltage Measurement... 14:39:23 Voltage Offset Correction: v_off_ini = 779.787 uV, v_off_fin = 801.083 uV 14:39:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.709 uVs 14:39:27 I1Y Average and RMS of Measurements VT = -205.275 +- 2.433 uVs I1Y = -41.055 +- 0.487 uTm 14:39:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:39:35 Integrated Voltage Measurement... 14:39:43 Voltage Offset Correction: v_off_ini = 807.014 uV, v_off_fin = 797.567 uV 14:39:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.040 uVs 14:39:44 Integrated Voltage Measurement... 14:39:53 Voltage Offset Correction: v_off_ini = 783.362 uV, v_off_fin = 794.966 uV 14:39:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.133 uVs 14:39:53 Integrated Voltage Measurement... 14:40:02 Voltage Offset Correction: v_off_ini = 805.964 uV, v_off_fin = 788.345 uV 14:40:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.141 uVs 14:40:02 Integrated Voltage Measurement... 14:40:11 Voltage Offset Correction: v_off_ini = 797.898 uV, v_off_fin = 810.908 uV 14:40:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.977 uVs 14:40:11 Integrated Voltage Measurement... 14:40:20 Voltage Offset Correction: v_off_ini = 798.322 uV, v_off_fin = 809.214 uV 14:40:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.922 uVs 14:40:20 Integrated Voltage Measurement... 14:40:29 Voltage Offset Correction: v_off_ini = 818.065 uV, v_off_fin = 812.728 uV 14:40:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.141 uVs 14:40:31 I2X Average and RMS of Measurements VT = -115.059 +- 7.231 uVs I2X = 10.585 +- 0.665 uTm^2 14:40:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:40:39 Integrated Voltage Measurement... 14:40:48 Voltage Offset Correction: v_off_ini = 822.698 uV, v_off_fin = 827.369 uV 14:40:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.873 uVs 14:40:48 Integrated Voltage Measurement... 14:40:57 Voltage Offset Correction: v_off_ini = 814.160 uV, v_off_fin = 815.038 uV 14:40:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.902 uVs 14:40:57 Integrated Voltage Measurement... 14:41:06 Voltage Offset Correction: v_off_ini = 819.874 uV, v_off_fin = 812.083 uV 14:41:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.879 uVs 14:41:06 Integrated Voltage Measurement... 14:41:15 Voltage Offset Correction: v_off_ini = 807.385 uV, v_off_fin = 782.308 uV 14:41:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.655 uVs 14:41:15 Integrated Voltage Measurement... 14:41:24 Voltage Offset Correction: v_off_ini = 794.269 uV, v_off_fin = 792.548 uV 14:41:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.532 uVs 14:41:24 Integrated Voltage Measurement... 14:41:33 Voltage Offset Correction: v_off_ini = 789.876 uV, v_off_fin = 782.871 uV 14:41:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.715 uVs 14:41:36 I2Y Average and RMS of Measurements VT = -268.759 +- 4.867 uVs I2Y = -24.726 +- 0.448 uTm^2 14:41:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:41:44 Integrated Voltage Measurement... 14:41:53 Voltage Offset Correction: v_off_ini = 799.657 uV, v_off_fin = 781.705 uV 14:41:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -123.467 uVs 14:41:53 Integrated Voltage Measurement... 14:42:02 Voltage Offset Correction: v_off_ini = 786.006 uV, v_off_fin = 789.748 uV 14:42:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.186 uVs 14:42:02 Integrated Voltage Measurement... 14:42:11 Voltage Offset Correction: v_off_ini = 801.986 uV, v_off_fin = 779.552 uV 14:42:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.703 uVs 14:42:11 Integrated Voltage Measurement... 14:42:20 Voltage Offset Correction: v_off_ini = 784.337 uV, v_off_fin = 789.447 uV 14:42:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.258 uVs 14:42:21 Integrated Voltage Measurement... 14:42:30 Voltage Offset Correction: v_off_ini = 793.296 uV, v_off_fin = 795.826 uV 14:42:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.132 uVs 14:42:30 Integrated Voltage Measurement... 14:42:39 Voltage Offset Correction: v_off_ini = 798.767 uV, v_off_fin = 808.479 uV 14:42:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.662 uVs 14:42:43 I1X Average and RMS of Measurements VT = -126.401 +- 8.811 uVs I1X = 25.281 +- 1.761 uTm 14:42:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:42:50 Integrated Voltage Measurement... 14:42:59 Voltage Offset Correction: v_off_ini = 791.330 uV, v_off_fin = 779.553 uV 14:42:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.765 uVs 14:42:59 Integrated Voltage Measurement... 14:43:08 Voltage Offset Correction: v_off_ini = 781.231 uV, v_off_fin = 799.973 uV 14:43:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.409 uVs 14:43:08 Integrated Voltage Measurement... 14:43:17 Voltage Offset Correction: v_off_ini = 801.629 uV, v_off_fin = 808.800 uV 14:43:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.722 uVs 14:43:17 Integrated Voltage Measurement... 14:43:26 Voltage Offset Correction: v_off_ini = 804.881 uV, v_off_fin = 817.897 uV 14:43:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.929 uVs 14:43:26 Integrated Voltage Measurement... 14:43:35 Voltage Offset Correction: v_off_ini = 785.000 uV, v_off_fin = 774.067 uV 14:43:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.099 uVs 14:43:35 Integrated Voltage Measurement... 14:43:44 Voltage Offset Correction: v_off_ini = 791.295 uV, v_off_fin = 803.135 uV 14:43:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.127 uVs 14:43:48 I1Y Average and RMS of Measurements VT = -198.842 +- 11.668 uVs I1Y = -39.768 +- 2.334 uTm 14:43:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:43:56 Integrated Voltage Measurement... 14:44:04 Voltage Offset Correction: v_off_ini = 788.331 uV, v_off_fin = 781.715 uV 14:44:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.391 uVs 14:44:05 Integrated Voltage Measurement... 14:44:14 Voltage Offset Correction: v_off_ini = 786.308 uV, v_off_fin = 783.150 uV 14:44:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.704 uVs 14:44:14 Integrated Voltage Measurement... 14:44:23 Voltage Offset Correction: v_off_ini = 791.338 uV, v_off_fin = 772.625 uV 14:44:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.701 uVs 14:44:23 Integrated Voltage Measurement... 14:44:32 Voltage Offset Correction: v_off_ini = 793.266 uV, v_off_fin = 792.487 uV 14:44:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.731 uVs 14:44:32 Integrated Voltage Measurement... 14:44:41 Voltage Offset Correction: v_off_ini = 784.632 uV, v_off_fin = 776.610 uV 14:44:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.140 uVs 14:44:41 Integrated Voltage Measurement... 14:44:50 Voltage Offset Correction: v_off_ini = 791.777 uV, v_off_fin = 795.137 uV 14:44:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.875 uVs 14:44:52 I2X Average and RMS of Measurements VT = -121.424 +- 3.693 uVs I2X = 11.171 +- 0.340 uTm^2 14:44:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:45:00 Integrated Voltage Measurement... 14:45:09 Voltage Offset Correction: v_off_ini = 790.138 uV, v_off_fin = 807.266 uV 14:45:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.203 uVs 14:45:09 Integrated Voltage Measurement... 14:45:18 Voltage Offset Correction: v_off_ini = 806.729 uV, v_off_fin = 807.247 uV 14:45:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.816 uVs 14:45:18 Integrated Voltage Measurement... 14:45:27 Voltage Offset Correction: v_off_ini = 791.388 uV, v_off_fin = 783.127 uV 14:45:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.773 uVs 14:45:27 Integrated Voltage Measurement... 14:45:36 Voltage Offset Correction: v_off_ini = 803.275 uV, v_off_fin = 811.233 uV 14:45:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 261.372 uVs 14:45:36 Integrated Voltage Measurement... 14:45:45 Voltage Offset Correction: v_off_ini = 810.034 uV, v_off_fin = 802.464 uV 14:45:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.957 uVs 14:45:45 Integrated Voltage Measurement... 14:45:54 Voltage Offset Correction: v_off_ini = 790.603 uV, v_off_fin = 796.809 uV 14:45:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.080 uVs 14:45:57 I2Y Average and RMS of Measurements VT = -268.367 +- 7.955 uVs I2Y = -24.690 +- 0.732 uTm^2 14:46:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:05 Integrated Voltage Measurement... 14:46:14 Voltage Offset Correction: v_off_ini = 811.209 uV, v_off_fin = 805.307 uV 14:46:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -112.927 uVs 14:46:15 Integrated Voltage Measurement... 14:46:23 Voltage Offset Correction: v_off_ini = 812.530 uV, v_off_fin = 823.933 uV 14:46:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.696 uVs 14:46:24 Integrated Voltage Measurement... 14:46:33 Voltage Offset Correction: v_off_ini = 829.445 uV, v_off_fin = 819.598 uV 14:46:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.816 uVs 14:46:33 Integrated Voltage Measurement... 14:46:42 Voltage Offset Correction: v_off_ini = 829.712 uV, v_off_fin = 834.856 uV 14:46:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.047 uVs 14:46:42 Integrated Voltage Measurement... 14:46:51 Voltage Offset Correction: v_off_ini = 808.830 uV, v_off_fin = 817.506 uV 14:46:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.550 uVs 14:46:51 Integrated Voltage Measurement... 14:47:00 Voltage Offset Correction: v_off_ini = 808.396 uV, v_off_fin = 835.503 uV 14:47:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.818 uVs 14:47:04 I1X Average and RMS of Measurements VT = -107.476 +- 2.789 uVs I1X = 21.496 +- 0.559 uTm 14:47:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:11 Integrated Voltage Measurement... 14:47:20 Voltage Offset Correction: v_off_ini = 798.654 uV, v_off_fin = 799.216 uV 14:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.587 uVs 14:47:20 Integrated Voltage Measurement... 14:47:29 Voltage Offset Correction: v_off_ini = 798.110 uV, v_off_fin = 815.114 uV 14:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.416 uVs 14:47:29 Integrated Voltage Measurement... 14:47:38 Voltage Offset Correction: v_off_ini = 810.661 uV, v_off_fin = 799.601 uV 14:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.059 uVs 14:47:38 Integrated Voltage Measurement... 14:47:47 Voltage Offset Correction: v_off_ini = 803.128 uV, v_off_fin = 806.939 uV 14:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.467 uVs 14:47:47 Integrated Voltage Measurement... 14:47:56 Voltage Offset Correction: v_off_ini = 830.658 uV, v_off_fin = 832.168 uV 14:47:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.872 uVs 14:47:56 Integrated Voltage Measurement... 14:48:05 Voltage Offset Correction: v_off_ini = 826.475 uV, v_off_fin = 835.646 uV 14:48:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.784 uVs 14:48:09 I1Y Average and RMS of Measurements VT = -194.698 +- 8.747 uVs I1Y = -38.940 +- 1.749 uTm 14:48:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:17 Integrated Voltage Measurement... 14:48:26 Voltage Offset Correction: v_off_ini = 817.975 uV, v_off_fin = 827.818 uV 14:48:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.298 uVs 14:48:26 Integrated Voltage Measurement... 14:48:35 Voltage Offset Correction: v_off_ini = 830.183 uV, v_off_fin = 838.924 uV 14:48:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.368 uVs 14:48:35 Integrated Voltage Measurement... 14:48:44 Voltage Offset Correction: v_off_ini = 826.875 uV, v_off_fin = 863.433 uV 14:48:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.104 uVs 14:48:44 Integrated Voltage Measurement... 14:48:53 Voltage Offset Correction: v_off_ini = 838.765 uV, v_off_fin = 843.526 uV 14:48:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.896 uVs 14:48:53 Integrated Voltage Measurement... 14:49:02 Voltage Offset Correction: v_off_ini = 849.423 uV, v_off_fin = 836.567 uV 14:49:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.033 uVs 14:49:02 Integrated Voltage Measurement... 14:49:11 Voltage Offset Correction: v_off_ini = 834.941 uV, v_off_fin = 855.390 uV 14:49:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.469 uVs 14:49:13 I2X Average and RMS of Measurements VT = -121.695 +- 10.040 uVs I2X = 11.196 +- 0.924 uTm^2 14:49:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:21 Integrated Voltage Measurement... 14:49:30 Voltage Offset Correction: v_off_ini = 836.339 uV, v_off_fin = 845.873 uV 14:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.017 uVs 14:49:30 Integrated Voltage Measurement... 14:49:39 Voltage Offset Correction: v_off_ini = 841.139 uV, v_off_fin = 842.490 uV 14:49:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.284 uVs 14:49:39 Integrated Voltage Measurement... 14:49:48 Voltage Offset Correction: v_off_ini = 840.007 uV, v_off_fin = 838.943 uV 14:49:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.882 uVs 14:49:48 Integrated Voltage Measurement... 14:49:57 Voltage Offset Correction: v_off_ini = 854.095 uV, v_off_fin = 842.523 uV 14:49:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.666 uVs 14:49:57 Integrated Voltage Measurement... 14:50:06 Voltage Offset Correction: v_off_ini = 843.921 uV, v_off_fin = 844.922 uV 14:50:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.122 uVs 14:50:06 Integrated Voltage Measurement... 14:50:15 Voltage Offset Correction: v_off_ini = 832.458 uV, v_off_fin = 826.303 uV 14:50:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.858 uVs 14:50:18 I2Y Average and RMS of Measurements VT = -262.805 +- 4.267 uVs I2Y = -24.178 +- 0.393 uTm^2 14:50:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:50:27 Integrated Voltage Measurement... 14:50:36 Voltage Offset Correction: v_off_ini = 829.974 uV, v_off_fin = 836.014 uV 14:50:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.210 uVs 14:50:36 Integrated Voltage Measurement... 14:50:45 Voltage Offset Correction: v_off_ini = 849.647 uV, v_off_fin = 851.468 uV 14:50:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.567 uVs 14:50:45 Integrated Voltage Measurement... 14:50:54 Voltage Offset Correction: v_off_ini = 838.190 uV, v_off_fin = 827.458 uV 14:50:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.014 uVs 14:50:54 Integrated Voltage Measurement... 14:51:03 Voltage Offset Correction: v_off_ini = 844.938 uV, v_off_fin = 851.148 uV 14:51:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.827 uVs 14:51:03 Integrated Voltage Measurement... 14:51:12 Voltage Offset Correction: v_off_ini = 836.810 uV, v_off_fin = 846.429 uV 14:51:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.479 uVs 14:51:12 Integrated Voltage Measurement... 14:51:21 Voltage Offset Correction: v_off_ini = 846.946 uV, v_off_fin = 847.539 uV 14:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.023 uVs 14:51:25 I1X Average and RMS of Measurements VT = -108.187 +- 6.568 uVs I1X = 21.637 +- 1.314 uTm 14:51:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:51:32 Integrated Voltage Measurement... 14:51:41 Voltage Offset Correction: v_off_ini = 846.912 uV, v_off_fin = 835.037 uV 14:51:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.688 uVs 14:51:41 Integrated Voltage Measurement... 14:51:50 Voltage Offset Correction: v_off_ini = 832.411 uV, v_off_fin = 824.485 uV 14:51:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.254 uVs 14:51:50 Integrated Voltage Measurement... 14:51:59 Voltage Offset Correction: v_off_ini = 829.916 uV, v_off_fin = 825.783 uV 14:51:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.524 uVs 14:51:59 Integrated Voltage Measurement... 14:52:08 Voltage Offset Correction: v_off_ini = 845.810 uV, v_off_fin = 844.730 uV 14:52:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.983 uVs 14:52:08 Integrated Voltage Measurement... 14:52:17 Voltage Offset Correction: v_off_ini = 841.569 uV, v_off_fin = 835.903 uV 14:52:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.316 uVs 14:52:17 Integrated Voltage Measurement... 14:52:26 Voltage Offset Correction: v_off_ini = 850.997 uV, v_off_fin = 867.436 uV 14:52:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.603 uVs 14:52:30 I1Y Average and RMS of Measurements VT = -185.894 +- 8.020 uVs I1Y = -37.179 +- 1.604 uTm 14:52:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:52:38 Integrated Voltage Measurement... 14:52:47 Voltage Offset Correction: v_off_ini = 845.001 uV, v_off_fin = 861.755 uV 14:52:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.164 uVs 14:52:47 Integrated Voltage Measurement... 14:52:56 Voltage Offset Correction: v_off_ini = 850.461 uV, v_off_fin = 850.129 uV 14:52:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.415 uVs 14:52:56 Integrated Voltage Measurement... 14:53:05 Voltage Offset Correction: v_off_ini = 830.153 uV, v_off_fin = 857.135 uV 14:53:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.139 uVs 14:53:05 Integrated Voltage Measurement... 14:53:14 Voltage Offset Correction: v_off_ini = 874.874 uV, v_off_fin = 860.970 uV 14:53:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.986 uVs 14:53:14 Integrated Voltage Measurement... 14:53:23 Voltage Offset Correction: v_off_ini = 857.372 uV, v_off_fin = 863.844 uV 14:53:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.627 uVs 14:53:23 Integrated Voltage Measurement... 14:53:32 Voltage Offset Correction: v_off_ini = 861.704 uV, v_off_fin = 861.670 uV 14:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.817 uVs 14:53:34 I2X Average and RMS of Measurements VT = -108.024 +- 8.823 uVs I2X = 9.938 +- 0.812 uTm^2 14:53:39 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:53:42 Integrated Voltage Measurement... 14:53:51 Voltage Offset Correction: v_off_ini = 874.959 uV, v_off_fin = 882.119 uV 14:53:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.672 uVs 14:53:51 Integrated Voltage Measurement... 14:54:00 Voltage Offset Correction: v_off_ini = 905.959 uV, v_off_fin = 891.606 uV 14:54:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.667 uVs 14:54:00 Integrated Voltage Measurement... 14:54:09 Voltage Offset Correction: v_off_ini = 897.752 uV, v_off_fin = 882.317 uV 14:54:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.217 uVs 14:54:09 Integrated Voltage Measurement... 14:54:18 Voltage Offset Correction: v_off_ini = 879.035 uV, v_off_fin = 885.805 uV 14:54:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.612 uVs 14:54:18 Integrated Voltage Measurement... 14:54:27 Voltage Offset Correction: v_off_ini = 885.790 uV, v_off_fin = 874.613 uV 14:54:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.574 uVs 14:54:27 Integrated Voltage Measurement... 14:54:36 Voltage Offset Correction: v_off_ini = 869.744 uV, v_off_fin = 867.978 uV 14:54:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.745 uVs 14:54:39 I2Y Average and RMS of Measurements VT = -272.081 +- 6.811 uVs I2Y = -25.031 +- 0.627 uTm^2 14:54:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:54:48 Integrated Voltage Measurement... 14:54:57 Voltage Offset Correction: v_off_ini = 885.742 uV, v_off_fin = 868.100 uV 14:54:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -142.310 uVs 14:54:57 Integrated Voltage Measurement... 14:55:06 Voltage Offset Correction: v_off_ini = 884.471 uV, v_off_fin = 900.990 uV 14:55:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.791 uVs 14:55:06 Integrated Voltage Measurement... 14:55:15 Voltage Offset Correction: v_off_ini = 885.204 uV, v_off_fin = 896.639 uV 14:55:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.756 uVs 14:55:15 Integrated Voltage Measurement... 14:55:24 Voltage Offset Correction: v_off_ini = 870.954 uV, v_off_fin = 861.982 uV 14:55:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.176 uVs 14:55:24 Integrated Voltage Measurement... 14:55:33 Voltage Offset Correction: v_off_ini = 869.650 uV, v_off_fin = 877.729 uV 14:55:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.484 uVs 14:55:33 Integrated Voltage Measurement... 14:55:42 Voltage Offset Correction: v_off_ini = 892.937 uV, v_off_fin = 875.243 uV 14:55:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.530 uVs 14:55:46 I1X Average and RMS of Measurements VT = -100.174 +- 17.377 uVs I1X = 20.035 +- 3.476 uTm 14:55:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:55:53 Integrated Voltage Measurement... 14:56:02 Voltage Offset Correction: v_off_ini = 888.166 uV, v_off_fin = 890.735 uV 14:56:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.830 uVs 14:56:02 Integrated Voltage Measurement... 14:56:11 Voltage Offset Correction: v_off_ini = 879.468 uV, v_off_fin = 886.356 uV 14:56:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.042 uVs 14:56:11 Integrated Voltage Measurement... 14:56:20 Voltage Offset Correction: v_off_ini = 877.854 uV, v_off_fin = 856.518 uV 14:56:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.279 uVs 14:56:20 Integrated Voltage Measurement... 14:56:29 Voltage Offset Correction: v_off_ini = 881.081 uV, v_off_fin = 890.964 uV 14:56:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.772 uVs 14:56:29 Integrated Voltage Measurement... 14:56:38 Voltage Offset Correction: v_off_ini = 862.501 uV, v_off_fin = 864.399 uV 14:56:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.659 uVs 14:56:38 Integrated Voltage Measurement... 14:56:47 Voltage Offset Correction: v_off_ini = 860.983 uV, v_off_fin = 881.442 uV 14:56:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.894 uVs 14:56:51 I1Y Average and RMS of Measurements VT = -184.746 +- 6.315 uVs I1Y = -36.949 +- 1.263 uTm 14:56:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:56:59 Integrated Voltage Measurement... 14:57:08 Voltage Offset Correction: v_off_ini = 857.304 uV, v_off_fin = 850.212 uV 14:57:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.704 uVs 14:57:08 Integrated Voltage Measurement... 14:57:17 Voltage Offset Correction: v_off_ini = 856.258 uV, v_off_fin = 867.169 uV 14:57:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.910 uVs 14:57:17 Integrated Voltage Measurement... 14:57:26 Voltage Offset Correction: v_off_ini = 877.735 uV, v_off_fin = 858.526 uV 14:57:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.097 uVs 14:57:26 Integrated Voltage Measurement... 14:57:35 Voltage Offset Correction: v_off_ini = 857.462 uV, v_off_fin = 845.555 uV 14:57:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.959 uVs 14:57:35 Integrated Voltage Measurement... 14:57:44 Voltage Offset Correction: v_off_ini = 834.621 uV, v_off_fin = 830.971 uV 14:57:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.081 uVs 14:57:44 Integrated Voltage Measurement... 14:57:53 Voltage Offset Correction: v_off_ini = 849.567 uV, v_off_fin = 854.097 uV 14:57:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.612 uVs 14:57:55 I2X Average and RMS of Measurements VT = -111.727 +- 5.542 uVs I2X = 10.279 +- 0.510 uTm^2 14:58:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:58:03 Integrated Voltage Measurement... 14:58:12 Voltage Offset Correction: v_off_ini = 849.689 uV, v_off_fin = 854.830 uV 14:58:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.782 uVs 14:58:12 Integrated Voltage Measurement... 14:58:21 Voltage Offset Correction: v_off_ini = 849.822 uV, v_off_fin = 852.819 uV 14:58:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.206 uVs 14:58:21 Integrated Voltage Measurement... 14:58:30 Voltage Offset Correction: v_off_ini = 848.770 uV, v_off_fin = 834.924 uV 14:58:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.631 uVs 14:58:30 Integrated Voltage Measurement... 14:58:39 Voltage Offset Correction: v_off_ini = 817.273 uV, v_off_fin = 825.131 uV 14:58:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.998 uVs 14:58:39 Integrated Voltage Measurement... 14:58:48 Voltage Offset Correction: v_off_ini = 818.398 uV, v_off_fin = 824.226 uV 14:58:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.328 uVs 14:58:48 Integrated Voltage Measurement... 14:58:57 Voltage Offset Correction: v_off_ini = 827.300 uV, v_off_fin = 842.158 uV 14:58:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.801 uVs 14:59:00 I2Y Average and RMS of Measurements VT = -251.125 +- 6.279 uVs I2Y = -23.103 +- 0.578 uTm^2 14:59:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:59:12 Integrated Voltage Measurement... 14:59:21 Voltage Offset Correction: v_off_ini = 823.573 uV, v_off_fin = 829.550 uV 14:59:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -108.030 uVs 14:59:21 Integrated Voltage Measurement... 14:59:30 Voltage Offset Correction: v_off_ini = 823.793 uV, v_off_fin = 832.195 uV 14:59:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.163 uVs 14:59:30 Integrated Voltage Measurement... 14:59:39 Voltage Offset Correction: v_off_ini = 826.498 uV, v_off_fin = 826.902 uV 14:59:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.833 uVs 14:59:39 Integrated Voltage Measurement... 14:59:48 Voltage Offset Correction: v_off_ini = 823.192 uV, v_off_fin = 814.720 uV 14:59:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.635 uVs 14:59:48 Integrated Voltage Measurement... 14:59:57 Voltage Offset Correction: v_off_ini = 831.112 uV, v_off_fin = 841.562 uV 14:59:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.644 uVs 14:59:57 Integrated Voltage Measurement... 15:00:06 Voltage Offset Correction: v_off_ini = 825.876 uV, v_off_fin = 826.323 uV 15:00:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.357 uVs 15:00:10 I1X Average and RMS of Measurements VT = -110.111 +- 4.785 uVs I1X = 22.022 +- 0.957 uTm 15:00:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:00:17 Integrated Voltage Measurement... 15:00:26 Voltage Offset Correction: v_off_ini = 830.829 uV, v_off_fin = 815.391 uV 15:00:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.746 uVs 15:00:26 Integrated Voltage Measurement... 15:00:35 Voltage Offset Correction: v_off_ini = 834.215 uV, v_off_fin = 842.576 uV 15:00:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.657 uVs 15:00:35 Integrated Voltage Measurement... 15:00:44 Voltage Offset Correction: v_off_ini = 823.314 uV, v_off_fin = 841.293 uV 15:00:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.526 uVs 15:00:44 Integrated Voltage Measurement... 15:00:53 Voltage Offset Correction: v_off_ini = 832.136 uV, v_off_fin = 844.317 uV 15:00:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.804 uVs 15:00:53 Integrated Voltage Measurement... 15:01:02 Voltage Offset Correction: v_off_ini = 840.618 uV, v_off_fin = 822.385 uV 15:01:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.586 uVs 15:01:02 Integrated Voltage Measurement... 15:01:11 Voltage Offset Correction: v_off_ini = 819.221 uV, v_off_fin = 837.826 uV 15:01:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.597 uVs 15:01:15 I1Y Average and RMS of Measurements VT = -201.319 +- 2.913 uVs I1Y = -40.264 +- 0.583 uTm 15:01:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:01:20 Integrated Voltage Measurement... 15:01:29 Voltage Offset Correction: v_off_ini = 818.091 uV, v_off_fin = 801.736 uV 15:01:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.468 uVs 15:01:29 Integrated Voltage Measurement... 15:01:38 Voltage Offset Correction: v_off_ini = 812.736 uV, v_off_fin = 840.092 uV 15:01:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.827 uVs 15:01:38 Integrated Voltage Measurement... 15:01:47 Voltage Offset Correction: v_off_ini = 823.957 uV, v_off_fin = 810.475 uV 15:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.789 uVs 15:01:48 Integrated Voltage Measurement... 15:01:56 Voltage Offset Correction: v_off_ini = 815.167 uV, v_off_fin = 801.999 uV 15:01:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 158.269 uVs 15:01:57 Integrated Voltage Measurement... 15:02:06 Voltage Offset Correction: v_off_ini = 803.825 uV, v_off_fin = 805.071 uV 15:02:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.152 uVs 15:02:06 Integrated Voltage Measurement... 15:02:15 Voltage Offset Correction: v_off_ini = 795.736 uV, v_off_fin = 818.662 uV 15:02:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.824 uVs 15:02:17 I2X Average and RMS of Measurements VT = -127.388 +- 13.867 uVs I2X = 11.720 +- 1.276 uTm^2 15:02:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:02:22 Integrated Voltage Measurement... 15:02:31 Voltage Offset Correction: v_off_ini = 812.326 uV, v_off_fin = 817.948 uV 15:02:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.550 uVs 15:02:31 Integrated Voltage Measurement... 15:02:40 Voltage Offset Correction: v_off_ini = 796.238 uV, v_off_fin = 786.448 uV 15:02:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.034 uVs 15:02:40 Integrated Voltage Measurement... 15:02:49 Voltage Offset Correction: v_off_ini = 797.004 uV, v_off_fin = 806.197 uV 15:02:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.104 uVs 15:02:49 Integrated Voltage Measurement... 15:02:58 Voltage Offset Correction: v_off_ini = 798.925 uV, v_off_fin = 797.647 uV 15:02:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.238 uVs 15:02:58 Integrated Voltage Measurement... 15:03:07 Voltage Offset Correction: v_off_ini = 795.379 uV, v_off_fin = 795.540 uV 15:03:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.269 uVs 15:03:07 Integrated Voltage Measurement... 15:03:16 Voltage Offset Correction: v_off_ini = 793.444 uV, v_off_fin = 784.006 uV 15:03:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.907 uVs 15:03:19 I2Y Average and RMS of Measurements VT = -269.684 +- 9.830 uVs I2Y = -24.811 +- 0.904 uTm^2 15:03:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:03:27 Integrated Voltage Measurement... 15:03:36 Voltage Offset Correction: v_off_ini = 807.026 uV, v_off_fin = 787.237 uV 15:03:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -138.999 uVs 15:03:36 Integrated Voltage Measurement... 15:03:45 Voltage Offset Correction: v_off_ini = 791.912 uV, v_off_fin = 809.913 uV 15:03:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.416 uVs 15:03:45 Integrated Voltage Measurement... 15:03:54 Voltage Offset Correction: v_off_ini = 812.481 uV, v_off_fin = 809.639 uV 15:03:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.876 uVs 15:03:54 Integrated Voltage Measurement... 15:04:03 Voltage Offset Correction: v_off_ini = 804.100 uV, v_off_fin = 815.186 uV 15:04:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.455 uVs 15:04:03 Integrated Voltage Measurement... 15:04:12 Voltage Offset Correction: v_off_ini = 823.166 uV, v_off_fin = 814.061 uV 15:04:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.478 uVs 15:04:12 Integrated Voltage Measurement... 15:04:21 Voltage Offset Correction: v_off_ini = 795.059 uV, v_off_fin = 805.211 uV 15:04:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.087 uVs 15:04:25 I1X Average and RMS of Measurements VT = -121.385 +- 2.202 uVs I1X = 24.278 +- 0.441 uTm 15:04:28 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:04:32 Integrated Voltage Measurement... 15:04:41 Voltage Offset Correction: v_off_ini = 823.723 uV, v_off_fin = 812.365 uV 15:04:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.938 uVs 15:04:41 Integrated Voltage Measurement... 15:04:50 Voltage Offset Correction: v_off_ini = 820.291 uV, v_off_fin = 825.363 uV 15:04:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.495 uVs 15:04:50 Integrated Voltage Measurement... 15:04:59 Voltage Offset Correction: v_off_ini = 817.330 uV, v_off_fin = 832.953 uV 15:04:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.382 uVs 15:04:59 Integrated Voltage Measurement... 15:05:08 Voltage Offset Correction: v_off_ini = 852.315 uV, v_off_fin = 862.916 uV 15:05:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.322 uVs 15:05:08 Integrated Voltage Measurement... 15:05:17 Voltage Offset Correction: v_off_ini = 830.594 uV, v_off_fin = 815.531 uV 15:05:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.192 uVs 15:05:17 Integrated Voltage Measurement... 15:05:26 Voltage Offset Correction: v_off_ini = 827.440 uV, v_off_fin = 847.315 uV 15:05:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.535 uVs 15:05:31 I1Y Average and RMS of Measurements VT = -199.644 +- 3.121 uVs I1Y = -39.929 +- 0.625 uTm 15:05:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:05:36 Integrated Voltage Measurement... 15:05:45 Voltage Offset Correction: v_off_ini = 836.354 uV, v_off_fin = 833.241 uV 15:05:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.929 uVs 15:05:45 Integrated Voltage Measurement... 15:05:54 Voltage Offset Correction: v_off_ini = 849.879 uV, v_off_fin = 857.168 uV 15:05:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.312 uVs 15:05:54 Integrated Voltage Measurement... 15:06:03 Voltage Offset Correction: v_off_ini = 833.075 uV, v_off_fin = 825.053 uV 15:06:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.683 uVs 15:06:03 Integrated Voltage Measurement... 15:06:12 Voltage Offset Correction: v_off_ini = 853.808 uV, v_off_fin = 864.092 uV 15:06:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.931 uVs 15:06:12 Integrated Voltage Measurement... 15:06:21 Voltage Offset Correction: v_off_ini = 857.219 uV, v_off_fin = 849.615 uV 15:06:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.545 uVs 15:06:21 Integrated Voltage Measurement... 15:06:30 Voltage Offset Correction: v_off_ini = 850.271 uV, v_off_fin = 868.258 uV 15:06:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.918 uVs 15:06:32 I2X Average and RMS of Measurements VT = -116.553 +- 3.429 uVs I2X = 10.723 +- 0.316 uTm^2 15:06:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:06:37 Integrated Voltage Measurement... 15:06:46 Voltage Offset Correction: v_off_ini = 834.302 uV, v_off_fin = 834.673 uV 15:06:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.766 uVs 15:06:46 Integrated Voltage Measurement... 15:06:55 Voltage Offset Correction: v_off_ini = 854.988 uV, v_off_fin = 866.464 uV 15:06:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.071 uVs 15:06:56 Integrated Voltage Measurement... 15:07:05 Voltage Offset Correction: v_off_ini = 853.932 uV, v_off_fin = 866.448 uV 15:07:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -289.310 uVs 15:07:05 Integrated Voltage Measurement... 15:07:14 Voltage Offset Correction: v_off_ini = 840.307 uV, v_off_fin = 852.456 uV 15:07:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.252 uVs 15:07:14 Integrated Voltage Measurement... 15:07:23 Voltage Offset Correction: v_off_ini = 849.323 uV, v_off_fin = 853.798 uV 15:07:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.063 uVs 15:07:23 Integrated Voltage Measurement... 15:07:32 Voltage Offset Correction: v_off_ini = 854.641 uV, v_off_fin = 872.018 uV 15:07:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.388 uVs 15:07:34 I2Y Average and RMS of Measurements VT = -270.142 +- 7.878 uVs I2Y = -24.853 +- 0.725 uTm^2 15:07:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:42 Integrated Voltage Measurement... 15:07:51 Voltage Offset Correction: v_off_ini = 858.164 uV, v_off_fin = 853.298 uV 15:07:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -126.342 uVs 15:07:51 Integrated Voltage Measurement... 15:08:00 Voltage Offset Correction: v_off_ini = 849.481 uV, v_off_fin = 847.685 uV 15:08:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.386 uVs 15:08:00 Integrated Voltage Measurement... 15:08:09 Voltage Offset Correction: v_off_ini = 849.582 uV, v_off_fin = 852.458 uV 15:08:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.045 uVs 15:08:10 Integrated Voltage Measurement... 15:08:18 Voltage Offset Correction: v_off_ini = 838.955 uV, v_off_fin = 823.142 uV 15:08:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.294 uVs 15:08:19 Integrated Voltage Measurement... 15:08:28 Voltage Offset Correction: v_off_ini = 839.948 uV, v_off_fin = 850.809 uV 15:08:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.193 uVs 15:08:28 Integrated Voltage Measurement... 15:08:37 Voltage Offset Correction: v_off_ini = 864.409 uV, v_off_fin = 848.914 uV 15:08:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.177 uVs 15:08:41 I1X Average and RMS of Measurements VT = -113.573 +- 2.519 uVs I1X = 22.715 +- 0.504 uTm 15:08:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:48 Integrated Voltage Measurement... 15:08:57 Voltage Offset Correction: v_off_ini = 871.687 uV, v_off_fin = 857.719 uV 15:08:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.201 uVs 15:08:57 Integrated Voltage Measurement... 15:09:06 Voltage Offset Correction: v_off_ini = 870.185 uV, v_off_fin = 871.334 uV 15:09:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.574 uVs 15:09:06 Integrated Voltage Measurement... 15:09:15 Voltage Offset Correction: v_off_ini = 871.179 uV, v_off_fin = 869.658 uV 15:09:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.546 uVs 15:09:15 Integrated Voltage Measurement... 15:09:24 Voltage Offset Correction: v_off_ini = 879.528 uV, v_off_fin = 886.753 uV 15:09:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.867 uVs 15:09:24 Integrated Voltage Measurement... 15:09:33 Voltage Offset Correction: v_off_ini = 859.670 uV, v_off_fin = 843.899 uV 15:09:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.292 uVs 15:09:33 Integrated Voltage Measurement... 15:09:42 Voltage Offset Correction: v_off_ini = 866.609 uV, v_off_fin = 868.410 uV 15:09:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.321 uVs 15:09:46 I1Y Average and RMS of Measurements VT = -198.300 +- 3.887 uVs I1Y = -39.660 +- 0.777 uTm 15:09:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:51 Integrated Voltage Measurement... 15:10:00 Voltage Offset Correction: v_off_ini = 860.687 uV, v_off_fin = 853.504 uV 15:10:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.668 uVs 15:10:00 Integrated Voltage Measurement... 15:10:09 Voltage Offset Correction: v_off_ini = 858.669 uV, v_off_fin = 856.869 uV 15:10:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.283 uVs 15:10:09 Integrated Voltage Measurement... 15:10:18 Voltage Offset Correction: v_off_ini = 834.857 uV, v_off_fin = 825.567 uV 15:10:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.290 uVs 15:10:18 Integrated Voltage Measurement... 15:10:27 Voltage Offset Correction: v_off_ini = 824.394 uV, v_off_fin = 845.974 uV 15:10:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.895 uVs 15:10:27 Integrated Voltage Measurement... 15:10:36 Voltage Offset Correction: v_off_ini = 823.121 uV, v_off_fin = 818.127 uV 15:10:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.954 uVs 15:10:36 Integrated Voltage Measurement... 15:10:45 Voltage Offset Correction: v_off_ini = 833.854 uV, v_off_fin = 829.603 uV 15:10:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.537 uVs 15:10:48 I2X Average and RMS of Measurements VT = -106.771 +- 9.109 uVs I2X = 9.823 +- 0.838 uTm^2 15:10:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:53 Integrated Voltage Measurement... 15:11:02 Voltage Offset Correction: v_off_ini = 823.493 uV, v_off_fin = 826.715 uV 15:11:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -284.085 uVs 15:11:02 Integrated Voltage Measurement... 15:11:11 Voltage Offset Correction: v_off_ini = 821.592 uV, v_off_fin = 831.911 uV 15:11:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.308 uVs 15:11:11 Integrated Voltage Measurement... 15:11:20 Voltage Offset Correction: v_off_ini = 836.163 uV, v_off_fin = 828.360 uV 15:11:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.368 uVs 15:11:20 Integrated Voltage Measurement... 15:11:29 Voltage Offset Correction: v_off_ini = 842.778 uV, v_off_fin = 832.375 uV 15:11:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.746 uVs 15:11:29 Integrated Voltage Measurement... 15:11:38 Voltage Offset Correction: v_off_ini = 826.860 uV, v_off_fin = 831.769 uV 15:11:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.817 uVs 15:11:38 Integrated Voltage Measurement... 15:11:47 Voltage Offset Correction: v_off_ini = 821.540 uV, v_off_fin = 824.324 uV 15:11:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.932 uVs 15:11:49 I2Y Average and RMS of Measurements VT = -273.876 +- 5.068 uVs I2Y = -25.197 +- 0.467 uTm^2 15:11:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:11:58 Integrated Voltage Measurement... 15:12:07 Voltage Offset Correction: v_off_ini = 818.911 uV, v_off_fin = 827.859 uV 15:12:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.470 uVs 15:12:07 Integrated Voltage Measurement... 15:12:16 Voltage Offset Correction: v_off_ini = 821.588 uV, v_off_fin = 831.423 uV 15:12:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.758 uVs 15:12:16 Integrated Voltage Measurement... 15:12:25 Voltage Offset Correction: v_off_ini = 823.999 uV, v_off_fin = 811.303 uV 15:12:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.904 uVs 15:12:25 Integrated Voltage Measurement... 15:12:34 Voltage Offset Correction: v_off_ini = 812.786 uV, v_off_fin = 802.902 uV 15:12:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.672 uVs 15:12:34 Integrated Voltage Measurement... 15:12:43 Voltage Offset Correction: v_off_ini = 810.545 uV, v_off_fin = 804.012 uV 15:12:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.434 uVs 15:12:43 Integrated Voltage Measurement... 15:12:52 Voltage Offset Correction: v_off_ini = 813.550 uV, v_off_fin = 814.896 uV 15:12:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.138 uVs 15:12:56 I1X Average and RMS of Measurements VT = -97.896 +- 5.860 uVs I1X = 19.580 +- 1.172 uTm 15:12:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:13:03 Integrated Voltage Measurement... 15:13:12 Voltage Offset Correction: v_off_ini = 796.669 uV, v_off_fin = 797.252 uV 15:13:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.790 uVs 15:13:12 Integrated Voltage Measurement... 15:13:21 Voltage Offset Correction: v_off_ini = 809.687 uV, v_off_fin = 815.847 uV 15:13:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.103 uVs 15:13:21 Integrated Voltage Measurement... 15:13:30 Voltage Offset Correction: v_off_ini = 813.718 uV, v_off_fin = 804.418 uV 15:13:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.437 uVs 15:13:30 Integrated Voltage Measurement... 15:13:39 Voltage Offset Correction: v_off_ini = 788.214 uV, v_off_fin = 795.303 uV 15:13:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.194 uVs 15:13:39 Integrated Voltage Measurement... 15:13:48 Voltage Offset Correction: v_off_ini = 781.478 uV, v_off_fin = 785.299 uV 15:13:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.960 uVs 15:13:48 Integrated Voltage Measurement... 15:13:57 Voltage Offset Correction: v_off_ini = 812.108 uV, v_off_fin = 813.926 uV 15:13:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.828 uVs 15:14:01 I1Y Average and RMS of Measurements VT = -184.052 +- 7.034 uVs I1Y = -36.810 +- 1.407 uTm 15:14:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:14:06 Integrated Voltage Measurement... 15:14:15 Voltage Offset Correction: v_off_ini = 795.569 uV, v_off_fin = 797.211 uV 15:14:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.073 uVs 15:14:15 Integrated Voltage Measurement... 15:14:24 Voltage Offset Correction: v_off_ini = 805.542 uV, v_off_fin = 816.904 uV 15:14:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.087 uVs 15:14:24 Integrated Voltage Measurement... 15:14:33 Voltage Offset Correction: v_off_ini = 797.707 uV, v_off_fin = 775.449 uV 15:14:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.396 uVs 15:14:33 Integrated Voltage Measurement... 15:14:42 Voltage Offset Correction: v_off_ini = 778.843 uV, v_off_fin = 798.724 uV 15:14:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.344 uVs 15:14:42 Integrated Voltage Measurement... 15:14:51 Voltage Offset Correction: v_off_ini = 813.295 uV, v_off_fin = 781.556 uV 15:14:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.955 uVs 15:14:52 Integrated Voltage Measurement... 15:15:01 Voltage Offset Correction: v_off_ini = 786.894 uV, v_off_fin = 785.366 uV 15:15:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.360 uVs 15:15:03 I2X Average and RMS of Measurements VT = -118.702 +- 6.120 uVs I2X = 10.921 +- 0.563 uTm^2 15:15:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:15:08 Integrated Voltage Measurement... 15:15:17 Voltage Offset Correction: v_off_ini = 767.606 uV, v_off_fin = 777.924 uV 15:15:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.755 uVs 15:15:17 Integrated Voltage Measurement... 15:15:26 Voltage Offset Correction: v_off_ini = 764.438 uV, v_off_fin = 755.417 uV 15:15:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.538 uVs 15:15:26 Integrated Voltage Measurement... 15:15:35 Voltage Offset Correction: v_off_ini = 778.024 uV, v_off_fin = 747.763 uV 15:15:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.754 uVs 15:15:35 Integrated Voltage Measurement... 15:15:44 Voltage Offset Correction: v_off_ini = 755.794 uV, v_off_fin = 752.966 uV 15:15:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.091 uVs 15:15:44 Integrated Voltage Measurement... 15:15:53 Voltage Offset Correction: v_off_ini = 742.673 uV, v_off_fin = 768.400 uV 15:15:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.056 uVs 15:15:53 Integrated Voltage Measurement... 15:16:02 Voltage Offset Correction: v_off_ini = 749.969 uV, v_off_fin = 749.794 uV 15:16:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.335 uVs 15:16:05 I2Y Average and RMS of Measurements VT = -270.088 +- 3.646 uVs I2Y = -24.848 +- 0.335 uTm^2 15:16:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:16:13 Integrated Voltage Measurement... 15:16:22 Voltage Offset Correction: v_off_ini = 752.337 uV, v_off_fin = 746.417 uV 15:16:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -134.524 uVs 15:16:22 Integrated Voltage Measurement... 15:16:31 Voltage Offset Correction: v_off_ini = 736.669 uV, v_off_fin = 737.376 uV 15:16:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.519 uVs 15:16:31 Integrated Voltage Measurement... 15:16:40 Voltage Offset Correction: v_off_ini = 731.946 uV, v_off_fin = 737.910 uV 15:16:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.066 uVs 15:16:40 Integrated Voltage Measurement... 15:16:49 Voltage Offset Correction: v_off_ini = 765.039 uV, v_off_fin = 784.526 uV 15:16:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.749 uVs 15:16:49 Integrated Voltage Measurement... 15:16:58 Voltage Offset Correction: v_off_ini = 749.177 uV, v_off_fin = 752.149 uV 15:16:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.903 uVs 15:16:58 Integrated Voltage Measurement... 15:17:07 Voltage Offset Correction: v_off_ini = 765.556 uV, v_off_fin = 765.970 uV 15:17:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.570 uVs 15:17:11 I1X Average and RMS of Measurements VT = -103.555 +- 11.144 uVs I1X = 20.711 +- 2.229 uTm 15:17:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:17:18 Integrated Voltage Measurement... 15:17:27 Voltage Offset Correction: v_off_ini = 740.546 uV, v_off_fin = 729.543 uV 15:17:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.259 uVs 15:17:27 Integrated Voltage Measurement... 15:17:36 Voltage Offset Correction: v_off_ini = 737.575 uV, v_off_fin = 743.173 uV 15:17:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.272 uVs 15:17:36 Integrated Voltage Measurement... 15:17:45 Voltage Offset Correction: v_off_ini = 750.880 uV, v_off_fin = 736.415 uV 15:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.836 uVs 15:17:45 Integrated Voltage Measurement... 15:17:54 Voltage Offset Correction: v_off_ini = 766.555 uV, v_off_fin = 768.175 uV 15:17:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.545 uVs 15:17:54 Integrated Voltage Measurement... 15:18:03 Voltage Offset Correction: v_off_ini = 758.014 uV, v_off_fin = 738.769 uV 15:18:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.852 uVs 15:18:03 Integrated Voltage Measurement... 15:18:12 Voltage Offset Correction: v_off_ini = 756.298 uV, v_off_fin = 772.950 uV 15:18:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.689 uVs 15:18:16 I1Y Average and RMS of Measurements VT = -194.575 +- 6.944 uVs I1Y = -38.913 +- 1.387 uTm 15:18:19 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:18:22 Integrated Voltage Measurement... 15:18:31 Voltage Offset Correction: v_off_ini = 754.240 uV, v_off_fin = 760.563 uV 15:18:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.511 uVs 15:18:31 Integrated Voltage Measurement... 15:18:40 Voltage Offset Correction: v_off_ini = 755.020 uV, v_off_fin = 753.032 uV 15:18:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.494 uVs 15:18:40 Integrated Voltage Measurement... 15:18:49 Voltage Offset Correction: v_off_ini = 739.577 uV, v_off_fin = 736.514 uV 15:18:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.661 uVs 15:18:49 Integrated Voltage Measurement... 15:18:58 Voltage Offset Correction: v_off_ini = 717.909 uV, v_off_fin = 739.307 uV 15:18:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.698 uVs 15:18:58 Integrated Voltage Measurement... 15:19:07 Voltage Offset Correction: v_off_ini = 756.993 uV, v_off_fin = 739.366 uV 15:19:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.641 uVs 15:19:07 Integrated Voltage Measurement... 15:19:16 Voltage Offset Correction: v_off_ini = 745.984 uV, v_off_fin = 744.127 uV 15:19:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.814 uVs 15:19:18 I2X Average and RMS of Measurements VT = -119.303 +- 7.802 uVs I2X = 10.976 +- 0.718 uTm^2 15:19:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:19:23 Integrated Voltage Measurement... 15:19:32 Voltage Offset Correction: v_off_ini = 735.498 uV, v_off_fin = 733.153 uV 15:19:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.141 uVs 15:19:32 Integrated Voltage Measurement... 15:19:41 Voltage Offset Correction: v_off_ini = 748.378 uV, v_off_fin = 739.094 uV 15:19:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.571 uVs 15:19:41 Integrated Voltage Measurement... 15:19:50 Voltage Offset Correction: v_off_ini = 733.006 uV, v_off_fin = 741.920 uV 15:19:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.087 uVs 15:19:50 Integrated Voltage Measurement... 15:19:59 Voltage Offset Correction: v_off_ini = 751.873 uV, v_off_fin = 741.558 uV 15:20:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.263 uVs 15:20:00 Integrated Voltage Measurement... 15:20:09 Voltage Offset Correction: v_off_ini = 742.764 uV, v_off_fin = 737.248 uV 15:20:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.469 uVs 15:20:09 Integrated Voltage Measurement... 15:20:18 Voltage Offset Correction: v_off_ini = 747.770 uV, v_off_fin = 760.477 uV 15:20:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.789 uVs 15:20:20 I2Y Average and RMS of Measurements VT = -270.553 +- 2.556 uVs I2Y = -24.891 +- 0.235 uTm^2 15:20:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:20:40 Integrated Voltage Measurement... 15:20:49 Voltage Offset Correction: v_off_ini = 741.813 uV, v_off_fin = 730.374 uV 15:20:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.737 uVs 15:20:49 Integrated Voltage Measurement... 15:20:58 Voltage Offset Correction: v_off_ini = 719.654 uV, v_off_fin = 726.585 uV 15:20:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.371 uVs 15:20:58 Integrated Voltage Measurement... 15:21:07 Voltage Offset Correction: v_off_ini = 750.755 uV, v_off_fin = 747.868 uV 15:21:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.580 uVs 15:21:07 Integrated Voltage Measurement... 15:21:16 Voltage Offset Correction: v_off_ini = 734.309 uV, v_off_fin = 738.382 uV 15:21:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.943 uVs 15:21:16 Integrated Voltage Measurement... 15:21:25 Voltage Offset Correction: v_off_ini = 707.714 uV, v_off_fin = 721.575 uV 15:21:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.633 uVs 15:21:25 Integrated Voltage Measurement... 15:21:34 Voltage Offset Correction: v_off_ini = 724.873 uV, v_off_fin = 719.307 uV 15:21:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.237 uVs 15:21:39 I1X Average and RMS of Measurements VT = -109.417 +- 8.489 uVs I1X = 21.884 +- 1.698 uTm 15:21:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:21:45 Integrated Voltage Measurement... 15:21:54 Voltage Offset Correction: v_off_ini = 724.030 uV, v_off_fin = 720.242 uV 15:21:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.970 uVs 15:21:54 Integrated Voltage Measurement... 15:22:03 Voltage Offset Correction: v_off_ini = 725.498 uV, v_off_fin = 719.232 uV 15:22:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.881 uVs 15:22:03 Integrated Voltage Measurement... 15:22:12 Voltage Offset Correction: v_off_ini = 719.849 uV, v_off_fin = 727.262 uV 15:22:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.230 uVs 15:22:12 Integrated Voltage Measurement... 15:22:21 Voltage Offset Correction: v_off_ini = 721.788 uV, v_off_fin = 737.488 uV 15:22:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.444 uVs 15:22:21 Integrated Voltage Measurement... 15:22:30 Voltage Offset Correction: v_off_ini = 728.821 uV, v_off_fin = 722.185 uV 15:22:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.386 uVs 15:22:30 Integrated Voltage Measurement... 15:22:39 Voltage Offset Correction: v_off_ini = 718.286 uV, v_off_fin = 729.604 uV 15:22:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.062 uVs 15:22:44 I1Y Average and RMS of Measurements VT = -196.662 +- 4.478 uVs I1Y = -39.332 +- 0.896 uTm 15:22:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:22:51 Integrated Voltage Measurement... 15:23:00 Voltage Offset Correction: v_off_ini = 732.123 uV, v_off_fin = 733.821 uV 15:23:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.568 uVs 15:23:00 Integrated Voltage Measurement... 15:23:09 Voltage Offset Correction: v_off_ini = 731.903 uV, v_off_fin = 727.231 uV 15:23:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.175 uVs 15:23:10 Integrated Voltage Measurement... 15:23:19 Voltage Offset Correction: v_off_ini = 725.909 uV, v_off_fin = 710.249 uV 15:23:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.287 uVs 15:23:19 Integrated Voltage Measurement... 15:23:28 Voltage Offset Correction: v_off_ini = 722.370 uV, v_off_fin = 745.916 uV 15:23:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.468 uVs 15:23:28 Integrated Voltage Measurement... 15:23:37 Voltage Offset Correction: v_off_ini = 710.270 uV, v_off_fin = 696.335 uV 15:23:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.059 uVs 15:23:37 Integrated Voltage Measurement... 15:23:46 Voltage Offset Correction: v_off_ini = 699.694 uV, v_off_fin = 715.336 uV 15:23:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.935 uVs 15:23:48 I2X Average and RMS of Measurements VT = -110.082 +- 6.172 uVs I2X = 10.128 +- 0.568 uTm^2 15:23:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:23:56 Integrated Voltage Measurement... 15:24:05 Voltage Offset Correction: v_off_ini = 705.337 uV, v_off_fin = 712.398 uV 15:24:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.320 uVs 15:24:05 Integrated Voltage Measurement... 15:24:14 Voltage Offset Correction: v_off_ini = 697.828 uV, v_off_fin = 708.278 uV 15:24:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.227 uVs 15:24:14 Integrated Voltage Measurement... 15:24:23 Voltage Offset Correction: v_off_ini = 703.058 uV, v_off_fin = 708.814 uV 15:24:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.703 uVs 15:24:23 Integrated Voltage Measurement... 15:24:32 Voltage Offset Correction: v_off_ini = 713.617 uV, v_off_fin = 717.673 uV 15:24:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.720 uVs 15:24:32 Integrated Voltage Measurement... 15:24:41 Voltage Offset Correction: v_off_ini = 710.571 uV, v_off_fin = 695.241 uV 15:24:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.161 uVs 15:24:41 Integrated Voltage Measurement... 15:24:50 Voltage Offset Correction: v_off_ini = 704.556 uV, v_off_fin = 706.744 uV 15:24:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.251 uVs 15:24:52 I2Y Average and RMS of Measurements VT = -276.064 +- 6.725 uVs I2Y = -25.398 +- 0.619 uTm^2 15:24:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:25:01 Integrated Voltage Measurement... 15:25:10 Voltage Offset Correction: v_off_ini = 721.522 uV, v_off_fin = 700.007 uV 15:25:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.222 uVs 15:25:10 Integrated Voltage Measurement... 15:25:19 Voltage Offset Correction: v_off_ini = 715.887 uV, v_off_fin = 714.738 uV 15:25:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.496 uVs 15:25:19 Integrated Voltage Measurement... 15:25:28 Voltage Offset Correction: v_off_ini = 714.289 uV, v_off_fin = 712.420 uV 15:25:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.017 uVs 15:25:28 Integrated Voltage Measurement... 15:25:37 Voltage Offset Correction: v_off_ini = 725.592 uV, v_off_fin = 722.648 uV 15:25:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.623 uVs 15:25:38 Integrated Voltage Measurement... 15:25:47 Voltage Offset Correction: v_off_ini = 729.122 uV, v_off_fin = 729.517 uV 15:25:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.368 uVs 15:25:47 Integrated Voltage Measurement... 15:25:56 Voltage Offset Correction: v_off_ini = 724.501 uV, v_off_fin = 732.222 uV 15:25:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.016 uVs 15:26:00 I1X Average and RMS of Measurements VT = -106.457 +- 3.313 uVs I1X = 21.291 +- 0.663 uTm 15:26:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:26:07 Integrated Voltage Measurement... 15:26:16 Voltage Offset Correction: v_off_ini = 726.075 uV, v_off_fin = 707.730 uV 15:26:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.300 uVs 15:26:16 Integrated Voltage Measurement... 15:26:25 Voltage Offset Correction: v_off_ini = 711.611 uV, v_off_fin = 731.669 uV 15:26:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.033 uVs 15:26:25 Integrated Voltage Measurement... 15:26:34 Voltage Offset Correction: v_off_ini = 723.384 uV, v_off_fin = 729.264 uV 15:26:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.556 uVs 15:26:34 Integrated Voltage Measurement... 15:26:43 Voltage Offset Correction: v_off_ini = 742.960 uV, v_off_fin = 729.457 uV 15:26:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.243 uVs 15:26:43 Integrated Voltage Measurement... 15:26:52 Voltage Offset Correction: v_off_ini = 737.200 uV, v_off_fin = 717.572 uV 15:26:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.685 uVs 15:26:52 Integrated Voltage Measurement... 15:27:01 Voltage Offset Correction: v_off_ini = 739.709 uV, v_off_fin = 748.017 uV 15:27:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.672 uVs 15:27:05 I1Y Average and RMS of Measurements VT = -192.748 +- 3.578 uVs I1Y = -38.550 +- 0.716 uTm 15:27:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:27:13 Integrated Voltage Measurement... 15:27:22 Voltage Offset Correction: v_off_ini = 727.863 uV, v_off_fin = 721.699 uV 15:27:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.751 uVs 15:27:22 Integrated Voltage Measurement... 15:27:31 Voltage Offset Correction: v_off_ini = 749.253 uV, v_off_fin = 732.968 uV 15:27:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.039 uVs 15:27:31 Integrated Voltage Measurement... 15:27:40 Voltage Offset Correction: v_off_ini = 743.922 uV, v_off_fin = 732.654 uV 15:27:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.729 uVs 15:27:40 Integrated Voltage Measurement... 15:27:49 Voltage Offset Correction: v_off_ini = 752.464 uV, v_off_fin = 749.751 uV 15:27:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.068 uVs 15:27:49 Integrated Voltage Measurement... 15:27:58 Voltage Offset Correction: v_off_ini = 732.223 uV, v_off_fin = 734.754 uV 15:27:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.765 uVs 15:27:58 Integrated Voltage Measurement... 15:28:07 Voltage Offset Correction: v_off_ini = 741.667 uV, v_off_fin = 754.087 uV 15:28:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.744 uVs 15:28:09 I2X Average and RMS of Measurements VT = -116.016 +- 7.935 uVs I2X = 10.673 +- 0.730 uTm^2 15:28:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:28:17 Integrated Voltage Measurement... 15:28:26 Voltage Offset Correction: v_off_ini = 735.323 uV, v_off_fin = 735.012 uV 15:28:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.894 uVs 15:28:26 Integrated Voltage Measurement... 15:28:35 Voltage Offset Correction: v_off_ini = 740.160 uV, v_off_fin = 723.557 uV 15:28:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.251 uVs 15:28:35 Integrated Voltage Measurement... 15:28:44 Voltage Offset Correction: v_off_ini = 733.366 uV, v_off_fin = 747.798 uV 15:28:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.729 uVs 15:28:44 Integrated Voltage Measurement... 15:28:53 Voltage Offset Correction: v_off_ini = 759.721 uV, v_off_fin = 745.005 uV 15:28:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.594 uVs 15:28:53 Integrated Voltage Measurement... 15:29:02 Voltage Offset Correction: v_off_ini = 735.136 uV, v_off_fin = 749.725 uV 15:29:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.157 uVs 15:29:02 Integrated Voltage Measurement... 15:29:11 Voltage Offset Correction: v_off_ini = 751.186 uV, v_off_fin = 777.177 uV 15:29:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.269 uVs 15:29:14 I2Y Average and RMS of Measurements VT = -267.982 +- 4.010 uVs I2Y = -24.654 +- 0.369 uTm^2 15:29:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:23 Integrated Voltage Measurement... 15:29:31 Voltage Offset Correction: v_off_ini = 785.291 uV, v_off_fin = 767.987 uV 15:29:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.528 uVs 15:29:32 Integrated Voltage Measurement... 15:29:41 Voltage Offset Correction: v_off_ini = 771.545 uV, v_off_fin = 779.824 uV 15:29:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.823 uVs 15:29:41 Integrated Voltage Measurement... 15:29:50 Voltage Offset Correction: v_off_ini = 799.147 uV, v_off_fin = 768.011 uV 15:29:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -75.787 uVs 15:29:50 Integrated Voltage Measurement... 15:29:59 Voltage Offset Correction: v_off_ini = 772.801 uV, v_off_fin = 771.216 uV 15:29:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 106.587 uVs 15:29:59 Integrated Voltage Measurement... 15:30:08 Voltage Offset Correction: v_off_ini = 773.032 uV, v_off_fin = 771.113 uV 15:30:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -101.315 uVs 15:30:08 Integrated Voltage Measurement... 15:30:17 Voltage Offset Correction: v_off_ini = 775.829 uV, v_off_fin = 776.280 uV 15:30:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 86.930 uVs 15:30:21 I1X Average and RMS of Measurements VT = -94.328 +- 2.653 uVs I1X = 18.868 +- 0.530 uTm 15:30:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:28 Integrated Voltage Measurement... 15:30:37 Voltage Offset Correction: v_off_ini = 764.009 uV, v_off_fin = 746.505 uV 15:30:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.054 uVs 15:30:37 Integrated Voltage Measurement... 15:30:46 Voltage Offset Correction: v_off_ini = 747.586 uV, v_off_fin = 763.623 uV 15:30:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.553 uVs 15:30:46 Integrated Voltage Measurement... 15:30:55 Voltage Offset Correction: v_off_ini = 748.650 uV, v_off_fin = 728.123 uV 15:30:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.145 uVs 15:30:55 Integrated Voltage Measurement... 15:31:04 Voltage Offset Correction: v_off_ini = 737.227 uV, v_off_fin = 756.468 uV 15:31:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.666 uVs 15:31:04 Integrated Voltage Measurement... 15:31:13 Voltage Offset Correction: v_off_ini = 744.177 uV, v_off_fin = 719.000 uV 15:31:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.509 uVs 15:31:13 Integrated Voltage Measurement... 15:31:22 Voltage Offset Correction: v_off_ini = 729.920 uV, v_off_fin = 742.379 uV 15:31:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.533 uVs 15:31:26 I1Y Average and RMS of Measurements VT = -190.410 +- 4.518 uVs I1Y = -38.082 +- 0.904 uTm 15:31:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:34 Integrated Voltage Measurement... 15:31:43 Voltage Offset Correction: v_off_ini = 741.193 uV, v_off_fin = 744.551 uV 15:31:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.951 uVs 15:31:43 Integrated Voltage Measurement... 15:31:52 Voltage Offset Correction: v_off_ini = 748.347 uV, v_off_fin = 754.831 uV 15:31:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.513 uVs 15:31:52 Integrated Voltage Measurement... 15:32:01 Voltage Offset Correction: v_off_ini = 749.152 uV, v_off_fin = 749.698 uV 15:32:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.728 uVs 15:32:01 Integrated Voltage Measurement... 15:32:10 Voltage Offset Correction: v_off_ini = 745.589 uV, v_off_fin = 755.845 uV 15:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.898 uVs 15:32:10 Integrated Voltage Measurement... 15:32:19 Voltage Offset Correction: v_off_ini = 757.508 uV, v_off_fin = 748.635 uV 15:32:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.286 uVs 15:32:19 Integrated Voltage Measurement... 15:32:28 Voltage Offset Correction: v_off_ini = 724.585 uV, v_off_fin = 734.331 uV 15:32:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.432 uVs 15:32:30 I2X Average and RMS of Measurements VT = -111.301 +- 9.883 uVs I2X = 10.240 +- 0.909 uTm^2 15:32:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:32:38 Integrated Voltage Measurement... 15:32:47 Voltage Offset Correction: v_off_ini = 746.059 uV, v_off_fin = 757.591 uV 15:32:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.626 uVs 15:32:47 Integrated Voltage Measurement... 15:32:56 Voltage Offset Correction: v_off_ini = 748.801 uV, v_off_fin = 727.338 uV 15:32:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.823 uVs 15:32:56 Integrated Voltage Measurement... 15:33:05 Voltage Offset Correction: v_off_ini = 733.953 uV, v_off_fin = 737.626 uV 15:33:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.180 uVs 15:33:05 Integrated Voltage Measurement... 15:33:14 Voltage Offset Correction: v_off_ini = 724.922 uV, v_off_fin = 719.773 uV 15:33:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.824 uVs 15:33:14 Integrated Voltage Measurement... 15:33:23 Voltage Offset Correction: v_off_ini = 720.022 uV, v_off_fin = 732.046 uV 15:33:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.315 uVs 15:33:23 Integrated Voltage Measurement... 15:33:32 Voltage Offset Correction: v_off_ini = 732.996 uV, v_off_fin = 719.019 uV 15:33:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.146 uVs 15:33:35 I2Y Average and RMS of Measurements VT = -257.486 +- 4.747 uVs I2Y = -23.689 +- 0.437 uTm^2 15:33:39 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:33:44 Integrated Voltage Measurement... 15:33:53 Voltage Offset Correction: v_off_ini = 744.848 uV, v_off_fin = 735.738 uV 15:33:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -94.006 uVs 15:33:53 Integrated Voltage Measurement... 15:34:02 Voltage Offset Correction: v_off_ini = 736.301 uV, v_off_fin = 719.332 uV 15:34:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.405 uVs 15:34:02 Integrated Voltage Measurement... 15:34:11 Voltage Offset Correction: v_off_ini = 731.380 uV, v_off_fin = 726.919 uV 15:34:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.537 uVs 15:34:11 Integrated Voltage Measurement... 15:34:20 Voltage Offset Correction: v_off_ini = 749.588 uV, v_off_fin = 751.535 uV 15:34:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.509 uVs 15:34:20 Integrated Voltage Measurement... 15:34:29 Voltage Offset Correction: v_off_ini = 712.700 uV, v_off_fin = 705.968 uV 15:34:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.911 uVs 15:34:29 Integrated Voltage Measurement... 15:34:38 Voltage Offset Correction: v_off_ini = 715.763 uV, v_off_fin = 709.558 uV 15:34:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.413 uVs 15:34:42 I1X Average and RMS of Measurements VT = -90.963 +- 1.592 uVs I1X = 18.193 +- 0.319 uTm 15:34:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:34:49 Integrated Voltage Measurement... 15:34:58 Voltage Offset Correction: v_off_ini = 709.113 uV, v_off_fin = 702.807 uV 15:34:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.730 uVs 15:34:58 Integrated Voltage Measurement... 15:35:07 Voltage Offset Correction: v_off_ini = 717.863 uV, v_off_fin = 723.381 uV 15:35:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.626 uVs 15:35:07 Integrated Voltage Measurement... 15:35:16 Voltage Offset Correction: v_off_ini = 736.587 uV, v_off_fin = 726.166 uV 15:35:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.405 uVs 15:35:16 Integrated Voltage Measurement... 15:35:25 Voltage Offset Correction: v_off_ini = 725.498 uV, v_off_fin = 730.849 uV 15:35:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.978 uVs 15:35:25 Integrated Voltage Measurement... 15:35:34 Voltage Offset Correction: v_off_ini = 718.444 uV, v_off_fin = 715.575 uV 15:35:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.574 uVs 15:35:34 Integrated Voltage Measurement... 15:35:43 Voltage Offset Correction: v_off_ini = 721.410 uV, v_off_fin = 721.684 uV 15:35:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.937 uVs 15:35:47 I1Y Average and RMS of Measurements VT = -193.042 +- 4.345 uVs I1Y = -38.608 +- 0.869 uTm 15:35:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:35:55 Integrated Voltage Measurement... 15:36:04 Voltage Offset Correction: v_off_ini = 727.509 uV, v_off_fin = 718.879 uV 15:36:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.310 uVs 15:36:04 Integrated Voltage Measurement... 15:36:13 Voltage Offset Correction: v_off_ini = 752.469 uV, v_off_fin = 750.445 uV 15:36:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.200 uVs 15:36:13 Integrated Voltage Measurement... 15:36:22 Voltage Offset Correction: v_off_ini = 725.679 uV, v_off_fin = 722.639 uV 15:36:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.795 uVs 15:36:22 Integrated Voltage Measurement... 15:36:31 Voltage Offset Correction: v_off_ini = 751.328 uV, v_off_fin = 739.847 uV 15:36:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.634 uVs 15:36:31 Integrated Voltage Measurement... 15:36:40 Voltage Offset Correction: v_off_ini = 723.789 uV, v_off_fin = 720.477 uV 15:36:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.561 uVs 15:36:40 Integrated Voltage Measurement... 15:36:49 Voltage Offset Correction: v_off_ini = 724.302 uV, v_off_fin = 729.356 uV 15:36:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.180 uVs 15:36:51 I2X Average and RMS of Measurements VT = -109.780 +- 3.306 uVs I2X = 10.100 +- 0.304 uTm^2 15:36:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:36:59 Integrated Voltage Measurement... 15:37:08 Voltage Offset Correction: v_off_ini = 708.102 uV, v_off_fin = 718.447 uV 15:37:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.358 uVs 15:37:08 Integrated Voltage Measurement... 15:37:17 Voltage Offset Correction: v_off_ini = 711.262 uV, v_off_fin = 707.918 uV 15:37:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.124 uVs 15:37:17 Integrated Voltage Measurement... 15:37:26 Voltage Offset Correction: v_off_ini = 717.237 uV, v_off_fin = 729.919 uV 15:37:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.975 uVs 15:37:26 Integrated Voltage Measurement... 15:37:35 Voltage Offset Correction: v_off_ini = 726.969 uV, v_off_fin = 738.261 uV 15:37:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.233 uVs 15:37:35 Integrated Voltage Measurement... 15:37:44 Voltage Offset Correction: v_off_ini = 730.183 uV, v_off_fin = 737.113 uV 15:37:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.137 uVs 15:37:44 Integrated Voltage Measurement... 15:37:53 Voltage Offset Correction: v_off_ini = 724.639 uV, v_off_fin = 720.423 uV 15:37:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.495 uVs 15:37:56 I2Y Average and RMS of Measurements VT = -260.220 +- 3.862 uVs I2Y = -23.940 +- 0.355 uTm^2 15:38:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:38:05 Integrated Voltage Measurement... 15:38:14 Voltage Offset Correction: v_off_ini = 724.535 uV, v_off_fin = 714.933 uV 15:38:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.037 uVs 15:38:14 Integrated Voltage Measurement... 15:38:23 Voltage Offset Correction: v_off_ini = 701.800 uV, v_off_fin = 730.239 uV 15:38:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.082 uVs 15:38:23 Integrated Voltage Measurement... 15:38:32 Voltage Offset Correction: v_off_ini = 723.149 uV, v_off_fin = 717.551 uV 15:38:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.353 uVs 15:38:32 Integrated Voltage Measurement... 15:38:41 Voltage Offset Correction: v_off_ini = 737.927 uV, v_off_fin = 758.084 uV 15:38:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 77.037 uVs 15:38:41 Integrated Voltage Measurement... 15:38:50 Voltage Offset Correction: v_off_ini = 736.339 uV, v_off_fin = 740.242 uV 15:38:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.460 uVs 15:38:50 Integrated Voltage Measurement... 15:38:59 Voltage Offset Correction: v_off_ini = 729.869 uV, v_off_fin = 726.482 uV 15:38:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.093 uVs 15:39:03 I1X Average and RMS of Measurements VT = -85.010 +- 8.645 uVs I1X = 17.003 +- 1.728 uTm 15:39:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:39:10 Integrated Voltage Measurement... 15:39:19 Voltage Offset Correction: v_off_ini = 733.738 uV, v_off_fin = 717.100 uV 15:39:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.033 uVs 15:39:19 Integrated Voltage Measurement... 15:39:28 Voltage Offset Correction: v_off_ini = 748.502 uV, v_off_fin = 743.866 uV 15:39:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.097 uVs 15:39:28 Integrated Voltage Measurement... 15:39:37 Voltage Offset Correction: v_off_ini = 742.635 uV, v_off_fin = 733.623 uV 15:39:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.398 uVs 15:39:37 Integrated Voltage Measurement... 15:39:46 Voltage Offset Correction: v_off_ini = 750.170 uV, v_off_fin = 747.872 uV 15:39:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.808 uVs 15:39:46 Integrated Voltage Measurement... 15:39:55 Voltage Offset Correction: v_off_ini = 733.187 uV, v_off_fin = 731.012 uV 15:39:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.265 uVs 15:39:55 Integrated Voltage Measurement... 15:40:04 Voltage Offset Correction: v_off_ini = 729.463 uV, v_off_fin = 755.710 uV 15:40:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 186.140 uVs 15:40:08 I1Y Average and RMS of Measurements VT = -178.790 +- 5.192 uVs I1Y = -35.759 +- 1.038 uTm 15:40:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:40:16 Integrated Voltage Measurement... 15:40:25 Voltage Offset Correction: v_off_ini = 723.548 uV, v_off_fin = 727.843 uV 15:40:25 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -99.591 uVs 15:40:25 Integrated Voltage Measurement... 15:40:34 Voltage Offset Correction: v_off_ini = 733.109 uV, v_off_fin = 755.329 uV 15:40:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.959 uVs 15:40:34 Integrated Voltage Measurement... 15:40:43 Voltage Offset Correction: v_off_ini = 749.571 uV, v_off_fin = 734.659 uV 15:40:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.221 uVs 15:40:43 Integrated Voltage Measurement... 15:40:52 Voltage Offset Correction: v_off_ini = 707.075 uV, v_off_fin = 750.396 uV 15:40:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.758 uVs 15:40:52 Integrated Voltage Measurement... 15:41:01 Voltage Offset Correction: v_off_ini = 743.151 uV, v_off_fin = 729.285 uV 15:41:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.847 uVs 15:41:01 Integrated Voltage Measurement... 15:41:10 Voltage Offset Correction: v_off_ini = 771.849 uV, v_off_fin = 772.982 uV 15:41:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.476 uVs 15:41:12 I2X Average and RMS of Measurements VT = -107.308 +- 10.194 uVs I2X = 9.872 +- 0.938 uTm^2 15:41:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:41:20 Integrated Voltage Measurement... 15:41:29 Voltage Offset Correction: v_off_ini = 750.574 uV, v_off_fin = 744.042 uV 15:41:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.124 uVs 15:41:29 Integrated Voltage Measurement... 15:41:38 Voltage Offset Correction: v_off_ini = 755.835 uV, v_off_fin = 757.346 uV 15:41:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.003 uVs 15:41:38 Integrated Voltage Measurement... 15:41:47 Voltage Offset Correction: v_off_ini = 744.305 uV, v_off_fin = 742.176 uV 15:41:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.763 uVs 15:41:47 Integrated Voltage Measurement... 15:41:56 Voltage Offset Correction: v_off_ini = 769.307 uV, v_off_fin = 763.943 uV 15:41:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.083 uVs 15:41:56 Integrated Voltage Measurement... 15:42:05 Voltage Offset Correction: v_off_ini = 773.952 uV, v_off_fin = 767.637 uV 15:42:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.892 uVs 15:42:05 Integrated Voltage Measurement... 15:42:14 Voltage Offset Correction: v_off_ini = 773.139 uV, v_off_fin = 772.465 uV 15:42:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.616 uVs 15:42:17 I2Y Average and RMS of Measurements VT = -249.913 +- 8.676 uVs I2Y = -22.992 +- 0.798 uTm^2 15:42:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:42:29 Integrated Voltage Measurement... 15:42:38 Voltage Offset Correction: v_off_ini = 767.029 uV, v_off_fin = 766.468 uV 15:42:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.320 uVs 15:42:38 Integrated Voltage Measurement... 15:42:47 Voltage Offset Correction: v_off_ini = 761.014 uV, v_off_fin = 746.900 uV 15:42:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.253 uVs 15:42:47 Integrated Voltage Measurement... 15:42:56 Voltage Offset Correction: v_off_ini = 764.271 uV, v_off_fin = 758.909 uV 15:42:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.254 uVs 15:42:56 Integrated Voltage Measurement... 15:43:05 Voltage Offset Correction: v_off_ini = 762.787 uV, v_off_fin = 772.580 uV 15:43:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.206 uVs 15:43:05 Integrated Voltage Measurement... 15:43:14 Voltage Offset Correction: v_off_ini = 756.407 uV, v_off_fin = 752.139 uV 15:43:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.983 uVs 15:43:14 Integrated Voltage Measurement... 15:43:23 Voltage Offset Correction: v_off_ini = 760.060 uV, v_off_fin = 754.140 uV 15:43:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.505 uVs 15:43:27 I1X Average and RMS of Measurements VT = -101.087 +- 9.809 uVs I1X = 20.218 +- 1.962 uTm 15:43:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:43:34 Integrated Voltage Measurement... 15:43:43 Voltage Offset Correction: v_off_ini = 761.822 uV, v_off_fin = 754.144 uV 15:43:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.106 uVs 15:43:43 Integrated Voltage Measurement... 15:43:52 Voltage Offset Correction: v_off_ini = 741.855 uV, v_off_fin = 764.354 uV 15:43:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.589 uVs 15:43:52 Integrated Voltage Measurement... 15:44:01 Voltage Offset Correction: v_off_ini = 767.046 uV, v_off_fin = 760.269 uV 15:44:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.619 uVs 15:44:01 Integrated Voltage Measurement... 15:44:10 Voltage Offset Correction: v_off_ini = 744.862 uV, v_off_fin = 758.049 uV 15:44:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.946 uVs 15:44:10 Integrated Voltage Measurement... 15:44:19 Voltage Offset Correction: v_off_ini = 753.880 uV, v_off_fin = 739.475 uV 15:44:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.134 uVs 15:44:19 Integrated Voltage Measurement... 15:44:28 Voltage Offset Correction: v_off_ini = 758.932 uV, v_off_fin = 766.238 uV 15:44:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.736 uVs 15:44:32 I1Y Average and RMS of Measurements VT = -198.855 +- 2.914 uVs I1Y = -39.771 +- 0.583 uTm 15:44:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:44:37 Integrated Voltage Measurement... 15:44:46 Voltage Offset Correction: v_off_ini = 750.153 uV, v_off_fin = 711.883 uV 15:44:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.787 uVs 15:44:46 Integrated Voltage Measurement... 15:44:55 Voltage Offset Correction: v_off_ini = 729.891 uV, v_off_fin = 739.700 uV 15:44:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.496 uVs 15:44:55 Integrated Voltage Measurement... 15:45:04 Voltage Offset Correction: v_off_ini = 735.820 uV, v_off_fin = 730.028 uV 15:45:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.112 uVs 15:45:04 Integrated Voltage Measurement... 15:45:13 Voltage Offset Correction: v_off_ini = 737.985 uV, v_off_fin = 733.759 uV 15:45:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.074 uVs 15:45:13 Integrated Voltage Measurement... 15:45:22 Voltage Offset Correction: v_off_ini = 729.569 uV, v_off_fin = 734.634 uV 15:45:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.752 uVs 15:45:22 Integrated Voltage Measurement... 15:45:31 Voltage Offset Correction: v_off_ini = 744.968 uV, v_off_fin = 746.969 uV 15:45:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.592 uVs 15:45:34 I2X Average and RMS of Measurements VT = -98.636 +- 5.180 uVs I2X = 9.074 +- 0.477 uTm^2 15:45:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:45:39 Integrated Voltage Measurement... 15:45:48 Voltage Offset Correction: v_off_ini = 748.259 uV, v_off_fin = 747.885 uV 15:45:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.109 uVs 15:45:48 Integrated Voltage Measurement... 15:45:57 Voltage Offset Correction: v_off_ini = 754.906 uV, v_off_fin = 750.035 uV 15:45:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.325 uVs 15:45:57 Integrated Voltage Measurement... 15:46:06 Voltage Offset Correction: v_off_ini = 740.268 uV, v_off_fin = 744.080 uV 15:46:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.436 uVs 15:46:06 Integrated Voltage Measurement... 15:46:15 Voltage Offset Correction: v_off_ini = 752.277 uV, v_off_fin = 755.172 uV 15:46:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.626 uVs 15:46:15 Integrated Voltage Measurement... 15:46:24 Voltage Offset Correction: v_off_ini = 738.126 uV, v_off_fin = 751.804 uV 15:46:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.599 uVs 15:46:24 Integrated Voltage Measurement... 15:46:33 Voltage Offset Correction: v_off_ini = 753.621 uV, v_off_fin = 739.724 uV 15:46:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.209 uVs 15:46:36 I2Y Average and RMS of Measurements VT = -258.384 +- 3.347 uVs I2Y = -23.771 +- 0.308 uTm^2 15:46:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:46:44 Integrated Voltage Measurement... 15:46:53 Voltage Offset Correction: v_off_ini = 727.405 uV, v_off_fin = 735.823 uV 15:46:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -121.925 uVs 15:46:53 Integrated Voltage Measurement... 15:47:02 Voltage Offset Correction: v_off_ini = 729.296 uV, v_off_fin = 732.884 uV 15:47:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.157 uVs 15:47:02 Integrated Voltage Measurement... 15:47:11 Voltage Offset Correction: v_off_ini = 723.288 uV, v_off_fin = 733.181 uV 15:47:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.218 uVs 15:47:11 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = 736.693 uV, v_off_fin = 755.006 uV 15:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.716 uVs 15:47:20 Integrated Voltage Measurement... 15:47:29 Voltage Offset Correction: v_off_ini = 760.026 uV, v_off_fin = 752.360 uV 15:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.945 uVs 15:47:29 Integrated Voltage Measurement... 15:47:38 Voltage Offset Correction: v_off_ini = 748.175 uV, v_off_fin = 730.372 uV 15:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.848 uVs 15:47:42 I1X Average and RMS of Measurements VT = -103.968 +- 5.149 uVs I1X = 20.795 +- 1.031 uTm 15:47:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:47:49 Integrated Voltage Measurement... 15:47:58 Voltage Offset Correction: v_off_ini = 721.553 uV, v_off_fin = 716.701 uV 15:47:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.108 uVs 15:47:58 Integrated Voltage Measurement... 15:48:07 Voltage Offset Correction: v_off_ini = 721.654 uV, v_off_fin = 732.989 uV 15:48:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.810 uVs 15:48:07 Integrated Voltage Measurement... 15:48:16 Voltage Offset Correction: v_off_ini = 731.176 uV, v_off_fin = 730.349 uV 15:48:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.015 uVs 15:48:16 Integrated Voltage Measurement... 15:48:25 Voltage Offset Correction: v_off_ini = 744.984 uV, v_off_fin = 762.752 uV 15:48:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.474 uVs 15:48:25 Integrated Voltage Measurement... 15:48:34 Voltage Offset Correction: v_off_ini = 758.916 uV, v_off_fin = 753.578 uV 15:48:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.946 uVs 15:48:34 Integrated Voltage Measurement... 15:48:43 Voltage Offset Correction: v_off_ini = 731.309 uV, v_off_fin = 759.675 uV 15:48:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.766 uVs 15:48:47 I1Y Average and RMS of Measurements VT = -195.353 +- 2.148 uVs I1Y = -39.071 +- 0.430 uTm 15:48:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:48:52 Integrated Voltage Measurement... 15:49:01 Voltage Offset Correction: v_off_ini = 739.244 uV, v_off_fin = 727.320 uV 15:49:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.937 uVs 15:49:01 Integrated Voltage Measurement... 15:49:10 Voltage Offset Correction: v_off_ini = 722.644 uV, v_off_fin = 751.008 uV 15:49:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.998 uVs 15:49:10 Integrated Voltage Measurement... 15:49:19 Voltage Offset Correction: v_off_ini = 740.516 uV, v_off_fin = 724.870 uV 15:49:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.946 uVs 15:49:19 Integrated Voltage Measurement... 15:49:28 Voltage Offset Correction: v_off_ini = 744.286 uV, v_off_fin = 755.789 uV 15:49:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.309 uVs 15:49:28 Integrated Voltage Measurement... 15:49:37 Voltage Offset Correction: v_off_ini = 746.509 uV, v_off_fin = 740.963 uV 15:49:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.132 uVs 15:49:37 Integrated Voltage Measurement... 15:49:46 Voltage Offset Correction: v_off_ini = 748.604 uV, v_off_fin = 738.946 uV 15:49:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.050 uVs 15:49:49 I2X Average and RMS of Measurements VT = -109.229 +- 12.476 uVs I2X = 10.049 +- 1.148 uTm^2 15:49:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:49:54 Integrated Voltage Measurement... 15:50:03 Voltage Offset Correction: v_off_ini = 764.363 uV, v_off_fin = 750.335 uV 15:50:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.841 uVs 15:50:03 Integrated Voltage Measurement... 15:50:12 Voltage Offset Correction: v_off_ini = 755.267 uV, v_off_fin = 775.184 uV 15:50:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.700 uVs 15:50:12 Integrated Voltage Measurement... 15:50:21 Voltage Offset Correction: v_off_ini = 765.708 uV, v_off_fin = 771.086 uV 15:50:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.083 uVs 15:50:21 Integrated Voltage Measurement... 15:50:30 Voltage Offset Correction: v_off_ini = 764.167 uV, v_off_fin = 754.862 uV 15:50:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.175 uVs 15:50:30 Integrated Voltage Measurement... 15:50:39 Voltage Offset Correction: v_off_ini = 773.707 uV, v_off_fin = 757.508 uV 15:50:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.009 uVs 15:50:39 Integrated Voltage Measurement... 15:50:48 Voltage Offset Correction: v_off_ini = 744.426 uV, v_off_fin = 773.934 uV 15:50:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.571 uVs 15:50:50 I2Y Average and RMS of Measurements VT = -266.230 +- 8.933 uVs I2Y = -24.493 +- 0.822 uTm^2 15:50:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:59 Integrated Voltage Measurement... 15:51:08 Voltage Offset Correction: v_off_ini = 759.792 uV, v_off_fin = 777.567 uV 15:51:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.284 uVs 15:51:08 Integrated Voltage Measurement... 15:51:17 Voltage Offset Correction: v_off_ini = 781.788 uV, v_off_fin = 792.822 uV 15:51:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.521 uVs 15:51:17 Integrated Voltage Measurement... 15:51:26 Voltage Offset Correction: v_off_ini = 782.662 uV, v_off_fin = 781.909 uV 15:51:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.935 uVs 15:51:26 Integrated Voltage Measurement... 15:51:35 Voltage Offset Correction: v_off_ini = 768.396 uV, v_off_fin = 779.487 uV 15:51:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.401 uVs 15:51:35 Integrated Voltage Measurement... 15:51:44 Voltage Offset Correction: v_off_ini = 786.121 uV, v_off_fin = 768.574 uV 15:51:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.328 uVs 15:51:44 Integrated Voltage Measurement... 15:51:53 Voltage Offset Correction: v_off_ini = 785.258 uV, v_off_fin = 802.869 uV 15:51:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.006 uVs 15:51:57 I1X Average and RMS of Measurements VT = -87.913 +- 12.729 uVs I1X = 17.583 +- 2.546 uTm 15:52:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:04 Integrated Voltage Measurement... 15:52:13 Voltage Offset Correction: v_off_ini = 770.852 uV, v_off_fin = 781.753 uV 15:52:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -171.501 uVs 15:52:13 Integrated Voltage Measurement... 15:52:22 Voltage Offset Correction: v_off_ini = 786.097 uV, v_off_fin = 790.288 uV 15:52:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.597 uVs 15:52:22 Integrated Voltage Measurement... 15:52:31 Voltage Offset Correction: v_off_ini = 776.397 uV, v_off_fin = 774.861 uV 15:52:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.698 uVs 15:52:31 Integrated Voltage Measurement... 15:52:40 Voltage Offset Correction: v_off_ini = 791.475 uV, v_off_fin = 800.678 uV 15:52:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.170 uVs 15:52:40 Integrated Voltage Measurement... 15:52:49 Voltage Offset Correction: v_off_ini = 756.252 uV, v_off_fin = 761.550 uV 15:52:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.455 uVs 15:52:49 Integrated Voltage Measurement... 15:52:58 Voltage Offset Correction: v_off_ini = 785.730 uV, v_off_fin = 788.114 uV 15:52:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.790 uVs 15:53:02 I1Y Average and RMS of Measurements VT = -190.369 +- 6.100 uVs I1Y = -38.075 +- 1.218 uTm 15:53:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:07 Integrated Voltage Measurement... 15:53:16 Voltage Offset Correction: v_off_ini = 775.133 uV, v_off_fin = 764.902 uV 15:53:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.116 uVs 15:53:16 Integrated Voltage Measurement... 15:53:25 Voltage Offset Correction: v_off_ini = 757.585 uV, v_off_fin = 767.316 uV 15:53:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.017 uVs 15:53:25 Integrated Voltage Measurement... 15:53:34 Voltage Offset Correction: v_off_ini = 748.594 uV, v_off_fin = 789.810 uV 15:53:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.481 uVs 15:53:34 Integrated Voltage Measurement... 15:53:43 Voltage Offset Correction: v_off_ini = 803.607 uV, v_off_fin = 806.333 uV 15:53:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.281 uVs 15:53:43 Integrated Voltage Measurement... 15:53:52 Voltage Offset Correction: v_off_ini = 782.338 uV, v_off_fin = 768.747 uV 15:53:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.867 uVs 15:53:52 Integrated Voltage Measurement... 15:54:01 Voltage Offset Correction: v_off_ini = 798.451 uV, v_off_fin = 799.631 uV 15:54:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.767 uVs 15:54:04 I2X Average and RMS of Measurements VT = -107.922 +- 6.438 uVs I2X = 9.929 +- 0.592 uTm^2 15:54:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:09 Integrated Voltage Measurement... 15:54:18 Voltage Offset Correction: v_off_ini = 771.970 uV, v_off_fin = 788.941 uV 15:54:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.598 uVs 15:54:18 Integrated Voltage Measurement... 15:54:27 Voltage Offset Correction: v_off_ini = 775.784 uV, v_off_fin = 787.583 uV 15:54:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.448 uVs 15:54:27 Integrated Voltage Measurement... 15:54:36 Voltage Offset Correction: v_off_ini = 771.275 uV, v_off_fin = 775.811 uV 15:54:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.548 uVs 15:54:36 Integrated Voltage Measurement... 15:54:45 Voltage Offset Correction: v_off_ini = 760.608 uV, v_off_fin = 776.925 uV 15:54:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.066 uVs 15:54:45 Integrated Voltage Measurement... 15:54:54 Voltage Offset Correction: v_off_ini = 766.547 uV, v_off_fin = 758.980 uV 15:54:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.212 uVs 15:54:54 Integrated Voltage Measurement... 15:55:03 Voltage Offset Correction: v_off_ini = 795.072 uV, v_off_fin = 790.116 uV 15:55:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.325 uVs 15:55:05 I2Y Average and RMS of Measurements VT = -256.700 +- 10.667 uVs I2Y = -23.616 +- 0.981 uTm^2 15:55:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:55:14 Integrated Voltage Measurement... 15:55:23 Voltage Offset Correction: v_off_ini = 805.167 uV, v_off_fin = 770.117 uV 15:55:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.826 uVs 15:55:23 Integrated Voltage Measurement... 15:55:32 Voltage Offset Correction: v_off_ini = 784.566 uV, v_off_fin = 787.975 uV 15:55:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.391 uVs 15:55:32 Integrated Voltage Measurement... 15:55:41 Voltage Offset Correction: v_off_ini = 795.453 uV, v_off_fin = 797.428 uV 15:55:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.116 uVs 15:55:41 Integrated Voltage Measurement... 15:55:50 Voltage Offset Correction: v_off_ini = 772.696 uV, v_off_fin = 777.500 uV 15:55:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.432 uVs 15:55:50 Integrated Voltage Measurement... 15:55:59 Voltage Offset Correction: v_off_ini = 776.863 uV, v_off_fin = 779.938 uV 15:55:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.769 uVs 15:55:59 Integrated Voltage Measurement... 15:56:08 Voltage Offset Correction: v_off_ini = 789.215 uV, v_off_fin = 766.208 uV 15:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.591 uVs 15:56:12 I1X Average and RMS of Measurements VT = -94.021 +- 15.940 uVs I1X = 18.805 +- 3.189 uTm 15:56:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:56:19 Integrated Voltage Measurement... 15:56:28 Voltage Offset Correction: v_off_ini = 780.108 uV, v_off_fin = 769.099 uV 15:56:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -188.375 uVs 15:56:28 Integrated Voltage Measurement... 15:56:37 Voltage Offset Correction: v_off_ini = 772.582 uV, v_off_fin = 792.098 uV 15:56:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.115 uVs 15:56:37 Integrated Voltage Measurement... 15:56:46 Voltage Offset Correction: v_off_ini = 791.967 uV, v_off_fin = 772.992 uV 15:56:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.199 uVs 15:56:46 Integrated Voltage Measurement... 15:56:55 Voltage Offset Correction: v_off_ini = 772.856 uV, v_off_fin = 793.629 uV 15:56:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.006 uVs 15:56:55 Integrated Voltage Measurement... 15:57:04 Voltage Offset Correction: v_off_ini = 779.878 uV, v_off_fin = 763.548 uV 15:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.930 uVs 15:57:04 Integrated Voltage Measurement... 15:57:13 Voltage Offset Correction: v_off_ini = 767.910 uV, v_off_fin = 782.780 uV 15:57:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.604 uVs 15:57:17 I1Y Average and RMS of Measurements VT = -193.538 +- 2.678 uVs I1Y = -38.706 +- 0.534 uTm 15:57:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:57:22 Integrated Voltage Measurement... 15:57:31 Voltage Offset Correction: v_off_ini = 783.220 uV, v_off_fin = 775.825 uV 15:57:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.150 uVs 15:57:31 Integrated Voltage Measurement... 15:57:40 Voltage Offset Correction: v_off_ini = 790.782 uV, v_off_fin = 803.555 uV 15:57:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.882 uVs 15:57:40 Integrated Voltage Measurement... 15:57:49 Voltage Offset Correction: v_off_ini = 800.321 uV, v_off_fin = 786.960 uV 15:57:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.925 uVs 15:57:49 Integrated Voltage Measurement... 15:57:58 Voltage Offset Correction: v_off_ini = 791.656 uV, v_off_fin = 810.152 uV 15:57:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.295 uVs 15:57:58 Integrated Voltage Measurement... 15:58:07 Voltage Offset Correction: v_off_ini = 801.990 uV, v_off_fin = 772.885 uV 15:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.775 uVs 15:58:07 Integrated Voltage Measurement... 15:58:16 Voltage Offset Correction: v_off_ini = 780.060 uV, v_off_fin = 794.903 uV 15:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.592 uVs 15:58:18 I2X Average and RMS of Measurements VT = -102.603 +- 6.311 uVs I2X = 9.440 +- 0.581 uTm^2 15:58:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:58:24 Integrated Voltage Measurement... 15:58:33 Voltage Offset Correction: v_off_ini = 792.844 uV, v_off_fin = 795.275 uV 15:58:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.254 uVs 15:58:33 Integrated Voltage Measurement... 15:58:42 Voltage Offset Correction: v_off_ini = 776.633 uV, v_off_fin = 764.717 uV 15:58:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.880 uVs 15:58:42 Integrated Voltage Measurement... 15:58:51 Voltage Offset Correction: v_off_ini = 761.524 uV, v_off_fin = 767.657 uV 15:58:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.960 uVs 15:58:51 Integrated Voltage Measurement... 15:59:00 Voltage Offset Correction: v_off_ini = 783.968 uV, v_off_fin = 781.842 uV 15:59:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.184 uVs 15:59:00 Integrated Voltage Measurement... 15:59:09 Voltage Offset Correction: v_off_ini = 782.645 uV, v_off_fin = 786.032 uV 15:59:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.960 uVs 15:59:09 Integrated Voltage Measurement... 15:59:18 Voltage Offset Correction: v_off_ini = 782.093 uV, v_off_fin = 778.152 uV 15:59:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.251 uVs 15:59:20 I2Y Average and RMS of Measurements VT = -265.415 +- 4.707 uVs I2Y = -24.418 +- 0.433 uTm^2 15:59:24 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:59:28 Integrated Voltage Measurement... 15:59:37 Voltage Offset Correction: v_off_ini = 794.618 uV, v_off_fin = 796.033 uV 15:59:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.492 uVs 15:59:37 Integrated Voltage Measurement... 15:59:46 Voltage Offset Correction: v_off_ini = 773.469 uV, v_off_fin = 775.953 uV 15:59:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.550 uVs 15:59:46 Integrated Voltage Measurement... 15:59:55 Voltage Offset Correction: v_off_ini = 769.072 uV, v_off_fin = 765.709 uV 15:59:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.277 uVs 15:59:55 Integrated Voltage Measurement... 16:00:04 Voltage Offset Correction: v_off_ini = 774.653 uV, v_off_fin = 780.472 uV 16:00:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.755 uVs 16:00:04 Integrated Voltage Measurement... 16:00:13 Voltage Offset Correction: v_off_ini = 789.746 uV, v_off_fin = 784.836 uV 16:00:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.862 uVs 16:00:14 Integrated Voltage Measurement... 16:00:22 Voltage Offset Correction: v_off_ini = 792.255 uV, v_off_fin = 789.808 uV 16:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.720 uVs 16:00:27 I1X Average and RMS of Measurements VT = -99.776 +- 12.642 uVs I1X = 19.955 +- 2.528 uTm 16:00:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:00:33 Integrated Voltage Measurement... 16:00:42 Voltage Offset Correction: v_off_ini = 786.037 uV, v_off_fin = 759.984 uV 16:00:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -181.100 uVs 16:00:42 Integrated Voltage Measurement... 16:00:51 Voltage Offset Correction: v_off_ini = 772.533 uV, v_off_fin = 781.439 uV 16:00:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.754 uVs 16:00:51 Integrated Voltage Measurement... 16:01:00 Voltage Offset Correction: v_off_ini = 755.913 uV, v_off_fin = 771.134 uV 16:01:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.206 uVs 16:01:00 Integrated Voltage Measurement... 16:01:09 Voltage Offset Correction: v_off_ini = 777.690 uV, v_off_fin = 791.305 uV 16:01:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 204.040 uVs 16:01:10 Integrated Voltage Measurement... 16:01:18 Voltage Offset Correction: v_off_ini = 769.056 uV, v_off_fin = 760.411 uV 16:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -197.766 uVs 16:01:19 Integrated Voltage Measurement... 16:01:27 Voltage Offset Correction: v_off_ini = 776.804 uV, v_off_fin = 786.764 uV 16:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 198.160 uVs 16:01:32 I1Y Average and RMS of Measurements VT = -197.504 +- 4.786 uVs I1Y = -39.496 +- 0.955 uTm 16:01:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:01:37 Integrated Voltage Measurement... 16:01:46 Voltage Offset Correction: v_off_ini = 745.203 uV, v_off_fin = 768.700 uV 16:01:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.765 uVs 16:01:46 Integrated Voltage Measurement... 16:01:55 Voltage Offset Correction: v_off_ini = 763.754 uV, v_off_fin = 778.644 uV 16:01:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.592 uVs 16:01:55 Integrated Voltage Measurement... 16:02:04 Voltage Offset Correction: v_off_ini = 771.832 uV, v_off_fin = 775.431 uV 16:02:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.986 uVs 16:02:04 Integrated Voltage Measurement... 16:02:13 Voltage Offset Correction: v_off_ini = 797.597 uV, v_off_fin = 787.879 uV 16:02:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.058 uVs 16:02:13 Integrated Voltage Measurement... 16:02:22 Voltage Offset Correction: v_off_ini = 780.093 uV, v_off_fin = 775.037 uV 16:02:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.229 uVs 16:02:22 Integrated Voltage Measurement... 16:02:31 Voltage Offset Correction: v_off_ini = 752.096 uV, v_off_fin = 773.879 uV 16:02:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.079 uVs 16:02:33 I2X Average and RMS of Measurements VT = -117.618 +- 9.541 uVs I2X = 10.821 +- 0.878 uTm^2 16:02:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:02:39 Integrated Voltage Measurement... 16:02:48 Voltage Offset Correction: v_off_ini = 746.018 uV, v_off_fin = 752.975 uV 16:02:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.177 uVs 16:02:48 Integrated Voltage Measurement... 16:02:57 Voltage Offset Correction: v_off_ini = 756.057 uV, v_off_fin = 765.253 uV 16:02:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.610 uVs 16:02:57 Integrated Voltage Measurement... 16:03:06 Voltage Offset Correction: v_off_ini = 752.700 uV, v_off_fin = 766.535 uV 16:03:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.379 uVs 16:03:06 Integrated Voltage Measurement... 16:03:15 Voltage Offset Correction: v_off_ini = 771.147 uV, v_off_fin = 794.671 uV 16:03:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.838 uVs 16:03:15 Integrated Voltage Measurement... 16:03:24 Voltage Offset Correction: v_off_ini = 787.724 uV, v_off_fin = 781.452 uV 16:03:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.816 uVs 16:03:24 Integrated Voltage Measurement... 16:03:33 Voltage Offset Correction: v_off_ini = 757.097 uV, v_off_fin = 763.520 uV 16:03:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.718 uVs 16:03:35 I2Y Average and RMS of Measurements VT = -256.590 +- 6.546 uVs I2Y = -23.606 +- 0.602 uTm^2 16:03:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:03:56 Integrated Voltage Measurement... 16:04:05 Voltage Offset Correction: v_off_ini = 761.922 uV, v_off_fin = 776.362 uV 16:04:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.821 uVs 16:04:05 Integrated Voltage Measurement... 16:04:14 Voltage Offset Correction: v_off_ini = 771.338 uV, v_off_fin = 769.897 uV 16:04:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.354 uVs 16:04:14 Integrated Voltage Measurement... 16:04:23 Voltage Offset Correction: v_off_ini = 774.657 uV, v_off_fin = 766.902 uV 16:04:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.033 uVs 16:04:23 Integrated Voltage Measurement... 16:04:32 Voltage Offset Correction: v_off_ini = 757.400 uV, v_off_fin = 744.854 uV 16:04:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.694 uVs 16:04:32 Integrated Voltage Measurement... 16:04:41 Voltage Offset Correction: v_off_ini = 749.036 uV, v_off_fin = 767.011 uV 16:04:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.083 uVs 16:04:41 Integrated Voltage Measurement... 16:04:50 Voltage Offset Correction: v_off_ini = 768.355 uV, v_off_fin = 748.114 uV 16:04:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.880 uVs 16:04:54 I1X Average and RMS of Measurements VT = -95.477 +- 0.868 uVs I1X = 19.096 +- 0.174 uTm 16:04:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:05:01 Integrated Voltage Measurement... 16:05:10 Voltage Offset Correction: v_off_ini = 759.266 uV, v_off_fin = 746.331 uV 16:05:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.347 uVs 16:05:10 Integrated Voltage Measurement... 16:05:19 Voltage Offset Correction: v_off_ini = 749.074 uV, v_off_fin = 750.265 uV 16:05:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.790 uVs 16:05:19 Integrated Voltage Measurement... 16:05:28 Voltage Offset Correction: v_off_ini = 751.995 uV, v_off_fin = 750.202 uV 16:05:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.524 uVs 16:05:28 Integrated Voltage Measurement... 16:05:37 Voltage Offset Correction: v_off_ini = 764.105 uV, v_off_fin = 754.357 uV 16:05:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.286 uVs 16:05:37 Integrated Voltage Measurement... 16:05:46 Voltage Offset Correction: v_off_ini = 761.519 uV, v_off_fin = 745.169 uV 16:05:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.565 uVs 16:05:46 Integrated Voltage Measurement... 16:05:55 Voltage Offset Correction: v_off_ini = 749.120 uV, v_off_fin = 761.846 uV 16:05:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.344 uVs 16:05:59 I1Y Average and RMS of Measurements VT = -203.976 +- 2.491 uVs I1Y = -40.795 +- 0.498 uTm 16:06:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:06:07 Integrated Voltage Measurement... 16:06:16 Voltage Offset Correction: v_off_ini = 710.649 uV, v_off_fin = 699.604 uV 16:06:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -92.151 uVs 16:06:16 Integrated Voltage Measurement... 16:06:25 Voltage Offset Correction: v_off_ini = 715.989 uV, v_off_fin = 743.134 uV 16:06:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.525 uVs 16:06:25 Integrated Voltage Measurement... 16:06:34 Voltage Offset Correction: v_off_ini = 737.498 uV, v_off_fin = 735.375 uV 16:06:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.821 uVs 16:06:34 Integrated Voltage Measurement... 16:06:43 Voltage Offset Correction: v_off_ini = 730.266 uV, v_off_fin = 738.329 uV 16:06:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 116.539 uVs 16:06:43 Integrated Voltage Measurement... 16:06:52 Voltage Offset Correction: v_off_ini = 723.474 uV, v_off_fin = 717.073 uV 16:06:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -98.879 uVs 16:06:52 Integrated Voltage Measurement... 16:07:01 Voltage Offset Correction: v_off_ini = 738.729 uV, v_off_fin = 739.957 uV 16:07:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.539 uVs 16:07:03 I2X Average and RMS of Measurements VT = -102.576 +- 4.841 uVs I2X = 9.437 +- 0.446 uTm^2 16:07:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:07:11 Integrated Voltage Measurement... 16:07:20 Voltage Offset Correction: v_off_ini = 735.900 uV, v_off_fin = 734.212 uV 16:07:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.513 uVs 16:07:20 Integrated Voltage Measurement... 16:07:29 Voltage Offset Correction: v_off_ini = 733.873 uV, v_off_fin = 746.803 uV 16:07:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.891 uVs 16:07:29 Integrated Voltage Measurement... 16:07:38 Voltage Offset Correction: v_off_ini = 751.210 uV, v_off_fin = 765.274 uV 16:07:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.205 uVs 16:07:38 Integrated Voltage Measurement... 16:07:47 Voltage Offset Correction: v_off_ini = 784.678 uV, v_off_fin = 781.593 uV 16:07:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.711 uVs 16:07:47 Integrated Voltage Measurement... 16:07:56 Voltage Offset Correction: v_off_ini = 767.273 uV, v_off_fin = 770.012 uV 16:07:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.652 uVs 16:07:56 Integrated Voltage Measurement... 16:08:05 Voltage Offset Correction: v_off_ini = 777.317 uV, v_off_fin = 778.267 uV 16:08:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.799 uVs 16:08:08 I2Y Average and RMS of Measurements VT = -260.462 +- 5.279 uVs I2Y = -23.962 +- 0.486 uTm^2 16:08:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:08:17 Integrated Voltage Measurement... 16:08:26 Voltage Offset Correction: v_off_ini = 780.873 uV, v_off_fin = 774.256 uV 16:08:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.688 uVs 16:08:26 Integrated Voltage Measurement... 16:08:35 Voltage Offset Correction: v_off_ini = 749.820 uV, v_off_fin = 769.868 uV 16:08:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.200 uVs 16:08:35 Integrated Voltage Measurement... 16:08:44 Voltage Offset Correction: v_off_ini = 756.713 uV, v_off_fin = 764.634 uV 16:08:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.694 uVs 16:08:44 Integrated Voltage Measurement... 16:08:53 Voltage Offset Correction: v_off_ini = 780.695 uV, v_off_fin = 772.959 uV 16:08:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.874 uVs 16:08:53 Integrated Voltage Measurement... 16:09:02 Voltage Offset Correction: v_off_ini = 771.675 uV, v_off_fin = 755.744 uV 16:09:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.929 uVs 16:09:02 Integrated Voltage Measurement... 16:09:11 Voltage Offset Correction: v_off_ini = 755.978 uV, v_off_fin = 748.485 uV 16:09:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.579 uVs 16:09:15 I1X Average and RMS of Measurements VT = -92.494 +- 3.385 uVs I1X = 18.499 +- 0.677 uTm 16:09:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:09:22 Integrated Voltage Measurement... 16:09:31 Voltage Offset Correction: v_off_ini = 763.766 uV, v_off_fin = 778.188 uV 16:09:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.079 uVs 16:09:31 Integrated Voltage Measurement... 16:09:40 Voltage Offset Correction: v_off_ini = 782.668 uV, v_off_fin = 791.043 uV 16:09:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.519 uVs 16:09:40 Integrated Voltage Measurement... 16:09:49 Voltage Offset Correction: v_off_ini = 780.685 uV, v_off_fin = 779.757 uV 16:09:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.180 uVs 16:09:49 Integrated Voltage Measurement... 16:09:58 Voltage Offset Correction: v_off_ini = 766.310 uV, v_off_fin = 779.070 uV 16:09:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.894 uVs 16:09:58 Integrated Voltage Measurement... 16:10:07 Voltage Offset Correction: v_off_ini = 781.506 uV, v_off_fin = 780.573 uV 16:10:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.662 uVs 16:10:07 Integrated Voltage Measurement... 16:10:16 Voltage Offset Correction: v_off_ini = 777.239 uV, v_off_fin = 791.480 uV 16:10:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.451 uVs 16:10:20 I1Y Average and RMS of Measurements VT = -195.298 +- 4.911 uVs I1Y = -39.060 +- 0.982 uTm 16:10:25 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:10:28 Integrated Voltage Measurement... 16:10:37 Voltage Offset Correction: v_off_ini = 785.341 uV, v_off_fin = 787.784 uV 16:10:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.139 uVs 16:10:37 Integrated Voltage Measurement... 16:10:46 Voltage Offset Correction: v_off_ini = 805.085 uV, v_off_fin = 810.771 uV 16:10:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.374 uVs 16:10:46 Integrated Voltage Measurement... 16:10:55 Voltage Offset Correction: v_off_ini = 780.818 uV, v_off_fin = 790.216 uV 16:10:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.973 uVs 16:10:55 Integrated Voltage Measurement... 16:11:04 Voltage Offset Correction: v_off_ini = 803.995 uV, v_off_fin = 795.671 uV 16:11:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.419 uVs 16:11:04 Integrated Voltage Measurement... 16:11:13 Voltage Offset Correction: v_off_ini = 785.793 uV, v_off_fin = 782.537 uV 16:11:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.249 uVs 16:11:13 Integrated Voltage Measurement... 16:11:22 Voltage Offset Correction: v_off_ini = 791.931 uV, v_off_fin = 806.666 uV 16:11:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.363 uVs 16:11:24 I2X Average and RMS of Measurements VT = -103.253 +- 6.377 uVs I2X = 9.499 +- 0.587 uTm^2 16:11:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:11:32 Integrated Voltage Measurement... 16:11:41 Voltage Offset Correction: v_off_ini = 815.021 uV, v_off_fin = 817.869 uV 16:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.494 uVs 16:11:41 Integrated Voltage Measurement... 16:11:50 Voltage Offset Correction: v_off_ini = 818.715 uV, v_off_fin = 810.772 uV 16:11:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.886 uVs 16:11:50 Integrated Voltage Measurement... 16:11:59 Voltage Offset Correction: v_off_ini = 816.152 uV, v_off_fin = 815.402 uV 16:11:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.948 uVs 16:11:59 Integrated Voltage Measurement... 16:12:08 Voltage Offset Correction: v_off_ini = 819.490 uV, v_off_fin = 814.546 uV 16:12:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.538 uVs 16:12:08 Integrated Voltage Measurement... 16:12:17 Voltage Offset Correction: v_off_ini = 808.956 uV, v_off_fin = 807.794 uV 16:12:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.509 uVs 16:12:17 Integrated Voltage Measurement... 16:12:26 Voltage Offset Correction: v_off_ini = 832.531 uV, v_off_fin = 830.534 uV 16:12:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.259 uVs 16:12:29 I2Y Average and RMS of Measurements VT = -267.106 +- 3.739 uVs I2Y = -24.574 +- 0.344 uTm^2 16:12:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:38 Integrated Voltage Measurement... 16:12:47 Voltage Offset Correction: v_off_ini = 846.384 uV, v_off_fin = 834.105 uV 16:12:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.820 uVs 16:12:47 Integrated Voltage Measurement... 16:12:56 Voltage Offset Correction: v_off_ini = 833.229 uV, v_off_fin = 844.922 uV 16:12:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.180 uVs 16:12:56 Integrated Voltage Measurement... 16:13:05 Voltage Offset Correction: v_off_ini = 849.611 uV, v_off_fin = 820.363 uV 16:13:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.117 uVs 16:13:05 Integrated Voltage Measurement... 16:13:14 Voltage Offset Correction: v_off_ini = 837.163 uV, v_off_fin = 850.732 uV 16:13:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.507 uVs 16:13:14 Integrated Voltage Measurement... 16:13:23 Voltage Offset Correction: v_off_ini = 851.529 uV, v_off_fin = 841.077 uV 16:13:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.153 uVs 16:13:23 Integrated Voltage Measurement... 16:13:32 Voltage Offset Correction: v_off_ini = 844.921 uV, v_off_fin = 843.714 uV 16:13:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.302 uVs 16:13:36 I1X Average and RMS of Measurements VT = -84.347 +- 6.487 uVs I1X = 16.869 +- 1.297 uTm 16:13:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:43 Integrated Voltage Measurement... 16:13:52 Voltage Offset Correction: v_off_ini = 834.933 uV, v_off_fin = 846.013 uV 16:13:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -196.654 uVs 16:13:52 Integrated Voltage Measurement... 16:14:01 Voltage Offset Correction: v_off_ini = 840.345 uV, v_off_fin = 852.498 uV 16:14:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.543 uVs 16:14:01 Integrated Voltage Measurement... 16:14:10 Voltage Offset Correction: v_off_ini = 842.443 uV, v_off_fin = 832.979 uV 16:14:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.291 uVs 16:14:10 Integrated Voltage Measurement... 16:14:19 Voltage Offset Correction: v_off_ini = 852.057 uV, v_off_fin = 855.182 uV 16:14:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.949 uVs 16:14:19 Integrated Voltage Measurement... 16:14:28 Voltage Offset Correction: v_off_ini = 857.035 uV, v_off_fin = 859.976 uV 16:14:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.448 uVs 16:14:28 Integrated Voltage Measurement... 16:14:37 Voltage Offset Correction: v_off_ini = 867.198 uV, v_off_fin = 885.864 uV 16:14:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.884 uVs 16:14:41 I1Y Average and RMS of Measurements VT = -197.461 +- 10.677 uVs I1Y = -39.493 +- 2.135 uTm 16:14:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:49 Integrated Voltage Measurement... 16:14:58 Voltage Offset Correction: v_off_ini = 867.403 uV, v_off_fin = 848.687 uV 16:14:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -89.048 uVs 16:14:58 Integrated Voltage Measurement... 16:15:07 Voltage Offset Correction: v_off_ini = 857.924 uV, v_off_fin = 857.821 uV 16:15:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.714 uVs 16:15:07 Integrated Voltage Measurement... 16:15:16 Voltage Offset Correction: v_off_ini = 849.748 uV, v_off_fin = 848.133 uV 16:15:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.327 uVs 16:15:16 Integrated Voltage Measurement... 16:15:25 Voltage Offset Correction: v_off_ini = 852.296 uV, v_off_fin = 868.762 uV 16:15:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.283 uVs 16:15:25 Integrated Voltage Measurement... 16:15:34 Voltage Offset Correction: v_off_ini = 851.150 uV, v_off_fin = 858.096 uV 16:15:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.822 uVs 16:15:34 Integrated Voltage Measurement... 16:15:43 Voltage Offset Correction: v_off_ini = 864.095 uV, v_off_fin = 873.221 uV 16:15:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.438 uVs 16:15:45 I2X Average and RMS of Measurements VT = -95.106 +- 5.419 uVs I2X = 8.750 +- 0.498 uTm^2 16:15:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:53 Integrated Voltage Measurement... 16:16:02 Voltage Offset Correction: v_off_ini = 827.875 uV, v_off_fin = 842.024 uV 16:16:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.601 uVs 16:16:02 Integrated Voltage Measurement... 16:16:11 Voltage Offset Correction: v_off_ini = 838.914 uV, v_off_fin = 855.637 uV 16:16:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.125 uVs 16:16:11 Integrated Voltage Measurement... 16:16:20 Voltage Offset Correction: v_off_ini = 826.876 uV, v_off_fin = 828.823 uV 16:16:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.566 uVs 16:16:20 Integrated Voltage Measurement... 16:16:29 Voltage Offset Correction: v_off_ini = 829.125 uV, v_off_fin = 839.741 uV 16:16:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.868 uVs 16:16:29 Integrated Voltage Measurement... 16:16:38 Voltage Offset Correction: v_off_ini = 828.740 uV, v_off_fin = 826.244 uV 16:16:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.187 uVs 16:16:38 Integrated Voltage Measurement... 16:16:47 Voltage Offset Correction: v_off_ini = 819.175 uV, v_off_fin = 814.035 uV 16:16:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.999 uVs 16:16:50 I2Y Average and RMS of Measurements VT = -258.058 +- 6.281 uVs I2Y = -23.741 +- 0.578 uTm^2 16:16:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:16:59 Integrated Voltage Measurement... 16:17:08 Voltage Offset Correction: v_off_ini = 846.280 uV, v_off_fin = 821.825 uV 16:17:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.687 uVs 16:17:08 Integrated Voltage Measurement... 16:17:17 Voltage Offset Correction: v_off_ini = 819.288 uV, v_off_fin = 829.676 uV 16:17:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.324 uVs 16:17:17 Integrated Voltage Measurement... 16:17:26 Voltage Offset Correction: v_off_ini = 828.244 uV, v_off_fin = 822.640 uV 16:17:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.234 uVs 16:17:26 Integrated Voltage Measurement... 16:17:35 Voltage Offset Correction: v_off_ini = 822.980 uV, v_off_fin = 836.190 uV 16:17:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.114 uVs 16:17:35 Integrated Voltage Measurement... 16:17:44 Voltage Offset Correction: v_off_ini = 830.734 uV, v_off_fin = 829.272 uV 16:17:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.028 uVs 16:17:44 Integrated Voltage Measurement... 16:17:53 Voltage Offset Correction: v_off_ini = 809.026 uV, v_off_fin = 824.269 uV 16:17:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.043 uVs 16:17:57 I1X Average and RMS of Measurements VT = -90.072 +- 8.939 uVs I1X = 18.014 +- 1.788 uTm 16:18:00 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:18:04 Integrated Voltage Measurement... 16:18:13 Voltage Offset Correction: v_off_ini = 837.226 uV, v_off_fin = 816.495 uV 16:18:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.101 uVs 16:18:13 Integrated Voltage Measurement... 16:18:22 Voltage Offset Correction: v_off_ini = 830.261 uV, v_off_fin = 820.631 uV 16:18:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.893 uVs 16:18:22 Integrated Voltage Measurement... 16:18:31 Voltage Offset Correction: v_off_ini = 818.899 uV, v_off_fin = 825.457 uV 16:18:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.971 uVs 16:18:31 Integrated Voltage Measurement... 16:18:40 Voltage Offset Correction: v_off_ini = 832.308 uV, v_off_fin = 853.305 uV 16:18:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.538 uVs 16:18:40 Integrated Voltage Measurement... 16:18:49 Voltage Offset Correction: v_off_ini = 819.800 uV, v_off_fin = 827.254 uV 16:18:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.561 uVs 16:18:49 Integrated Voltage Measurement... 16:18:58 Voltage Offset Correction: v_off_ini = 843.872 uV, v_off_fin = 851.112 uV 16:18:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.177 uVs 16:19:02 I1Y Average and RMS of Measurements VT = -193.540 +- 11.203 uVs I1Y = -38.708 +- 2.241 uTm 16:19:07 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:19:10 Integrated Voltage Measurement... 16:19:19 Voltage Offset Correction: v_off_ini = 822.043 uV, v_off_fin = 823.594 uV 16:19:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.475 uVs 16:19:19 Integrated Voltage Measurement... 16:19:28 Voltage Offset Correction: v_off_ini = 844.156 uV, v_off_fin = 843.048 uV 16:19:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.291 uVs 16:19:28 Integrated Voltage Measurement... 16:19:37 Voltage Offset Correction: v_off_ini = 833.325 uV, v_off_fin = 831.913 uV 16:19:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.687 uVs 16:19:37 Integrated Voltage Measurement... 16:19:46 Voltage Offset Correction: v_off_ini = 825.075 uV, v_off_fin = 842.154 uV 16:19:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.427 uVs 16:19:46 Integrated Voltage Measurement... 16:19:55 Voltage Offset Correction: v_off_ini = 835.597 uV, v_off_fin = 833.087 uV 16:19:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.527 uVs 16:19:55 Integrated Voltage Measurement... 16:20:04 Voltage Offset Correction: v_off_ini = 845.431 uV, v_off_fin = 842.827 uV 16:20:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.243 uVs 16:20:07 I2X Average and RMS of Measurements VT = -95.608 +- 8.750 uVs I2X = 8.796 +- 0.805 uTm^2 16:20:12 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:20:14 Integrated Voltage Measurement... 16:20:23 Voltage Offset Correction: v_off_ini = 844.140 uV, v_off_fin = 831.495 uV 16:20:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.192 uVs 16:20:23 Integrated Voltage Measurement... 16:20:32 Voltage Offset Correction: v_off_ini = 820.168 uV, v_off_fin = 834.698 uV 16:20:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.830 uVs 16:20:32 Integrated Voltage Measurement... 16:20:41 Voltage Offset Correction: v_off_ini = 813.052 uV, v_off_fin = 822.887 uV 16:20:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.061 uVs 16:20:41 Integrated Voltage Measurement... 16:20:50 Voltage Offset Correction: v_off_ini = 822.989 uV, v_off_fin = 821.605 uV 16:20:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.083 uVs 16:20:51 Integrated Voltage Measurement... 16:21:00 Voltage Offset Correction: v_off_ini = 807.742 uV, v_off_fin = 818.940 uV 16:21:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.067 uVs 16:21:00 Integrated Voltage Measurement... 16:21:09 Voltage Offset Correction: v_off_ini = 808.308 uV, v_off_fin = 823.749 uV 16:21:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.500 uVs 16:21:11 I2Y Average and RMS of Measurements VT = -251.456 +- 6.120 uVs I2Y = -23.134 +- 0.563 uTm^2 16:21:16 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:21:20 Integrated Voltage Measurement... 16:21:29 Voltage Offset Correction: v_off_ini = 813.131 uV, v_off_fin = 814.058 uV 16:21:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -84.613 uVs 16:21:29 Integrated Voltage Measurement... 16:21:38 Voltage Offset Correction: v_off_ini = 826.472 uV, v_off_fin = 818.811 uV 16:21:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.596 uVs 16:21:38 Integrated Voltage Measurement... 16:21:47 Voltage Offset Correction: v_off_ini = 812.330 uV, v_off_fin = 812.699 uV 16:21:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.634 uVs 16:21:47 Integrated Voltage Measurement... 16:21:56 Voltage Offset Correction: v_off_ini = 804.211 uV, v_off_fin = 802.031 uV 16:21:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.980 uVs 16:21:56 Integrated Voltage Measurement... 16:22:05 Voltage Offset Correction: v_off_ini = 783.223 uV, v_off_fin = 796.849 uV 16:22:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.394 uVs 16:22:05 Integrated Voltage Measurement... 16:22:14 Voltage Offset Correction: v_off_ini = 816.967 uV, v_off_fin = 827.970 uV 16:22:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.782 uVs 16:22:18 I1X Average and RMS of Measurements VT = -82.000 +- 1.643 uVs I1X = 16.401 +- 0.328 uTm 16:22:21 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:22:25 Integrated Voltage Measurement... 16:22:34 Voltage Offset Correction: v_off_ini = 827.552 uV, v_off_fin = 809.021 uV 16:22:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.132 uVs 16:22:34 Integrated Voltage Measurement... 16:22:43 Voltage Offset Correction: v_off_ini = 821.567 uV, v_off_fin = 842.385 uV 16:22:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.261 uVs 16:22:43 Integrated Voltage Measurement... 16:22:52 Voltage Offset Correction: v_off_ini = 824.741 uV, v_off_fin = 811.891 uV 16:22:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.153 uVs 16:22:52 Integrated Voltage Measurement... 16:23:01 Voltage Offset Correction: v_off_ini = 843.042 uV, v_off_fin = 844.327 uV 16:23:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.318 uVs 16:23:01 Integrated Voltage Measurement... 16:23:10 Voltage Offset Correction: v_off_ini = 838.647 uV, v_off_fin = 821.917 uV 16:23:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.991 uVs 16:23:10 Integrated Voltage Measurement... 16:23:19 Voltage Offset Correction: v_off_ini = 831.159 uV, v_off_fin = 844.532 uV 16:23:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.629 uVs 16:23:23 I1Y Average and RMS of Measurements VT = -188.581 +- 9.762 uVs I1Y = -37.716 +- 1.952 uTm 16:23:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:23:31 Integrated Voltage Measurement... 16:23:40 Voltage Offset Correction: v_off_ini = 819.641 uV, v_off_fin = 789.841 uV 16:23:40 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -103.905 uVs 16:23:40 Integrated Voltage Measurement... 16:23:49 Voltage Offset Correction: v_off_ini = 808.933 uV, v_off_fin = 812.735 uV 16:23:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.254 uVs 16:23:49 Integrated Voltage Measurement... 16:23:58 Voltage Offset Correction: v_off_ini = 804.569 uV, v_off_fin = 801.936 uV 16:23:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.948 uVs 16:23:58 Integrated Voltage Measurement... 16:24:07 Voltage Offset Correction: v_off_ini = 821.447 uV, v_off_fin = 813.255 uV 16:24:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.764 uVs 16:24:07 Integrated Voltage Measurement... 16:24:16 Voltage Offset Correction: v_off_ini = 821.201 uV, v_off_fin = 809.060 uV 16:24:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.374 uVs 16:24:16 Integrated Voltage Measurement... 16:24:25 Voltage Offset Correction: v_off_ini = 815.424 uV, v_off_fin = 828.771 uV 16:24:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.858 uVs 16:24:28 I2X Average and RMS of Measurements VT = -87.517 +- 10.244 uVs I2X = 8.051 +- 0.942 uTm^2 16:24:33 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:24:35 Integrated Voltage Measurement... 16:24:44 Voltage Offset Correction: v_off_ini = 802.889 uV, v_off_fin = 798.686 uV 16:24:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.559 uVs 16:24:44 Integrated Voltage Measurement... 16:24:53 Voltage Offset Correction: v_off_ini = 793.615 uV, v_off_fin = 799.370 uV 16:24:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.809 uVs 16:24:54 Integrated Voltage Measurement... 16:25:03 Voltage Offset Correction: v_off_ini = 802.181 uV, v_off_fin = 796.798 uV 16:25:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.480 uVs 16:25:03 Integrated Voltage Measurement... 16:25:12 Voltage Offset Correction: v_off_ini = 810.976 uV, v_off_fin = 791.810 uV 16:25:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.169 uVs 16:25:12 Integrated Voltage Measurement... 16:25:21 Voltage Offset Correction: v_off_ini = 757.644 uV, v_off_fin = 799.436 uV 16:25:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.348 uVs 16:25:21 Integrated Voltage Measurement... 16:25:30 Voltage Offset Correction: v_off_ini = 783.953 uV, v_off_fin = 788.223 uV 16:25:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.414 uVs 16:25:32 I2Y Average and RMS of Measurements VT = -245.630 +- 5.028 uVs I2Y = -22.598 +- 0.463 uTm^2 16:25:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:25:44 Integrated Voltage Measurement... 16:25:53 Voltage Offset Correction: v_off_ini = 786.486 uV, v_off_fin = 773.571 uV 16:25:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.365 uVs 16:25:53 Integrated Voltage Measurement... 16:26:02 Voltage Offset Correction: v_off_ini = 784.288 uV, v_off_fin = 780.784 uV 16:26:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.043 uVs 16:26:02 Integrated Voltage Measurement... 16:26:11 Voltage Offset Correction: v_off_ini = 782.803 uV, v_off_fin = 789.392 uV 16:26:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.914 uVs 16:26:11 Integrated Voltage Measurement... 16:26:20 Voltage Offset Correction: v_off_ini = 792.108 uV, v_off_fin = 788.224 uV 16:26:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.591 uVs 16:26:20 Integrated Voltage Measurement... 16:26:29 Voltage Offset Correction: v_off_ini = 783.822 uV, v_off_fin = 770.650 uV 16:26:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.101 uVs 16:26:29 Integrated Voltage Measurement... 16:26:38 Voltage Offset Correction: v_off_ini = 785.992 uV, v_off_fin = 794.322 uV 16:26:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.164 uVs 16:26:42 I1X Average and RMS of Measurements VT = -83.029 +- 7.252 uVs I1X = 16.606 +- 1.450 uTm 16:26:45 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:26:49 Integrated Voltage Measurement... 16:26:58 Voltage Offset Correction: v_off_ini = 774.539 uV, v_off_fin = 764.900 uV 16:26:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.940 uVs 16:26:58 Integrated Voltage Measurement... 16:27:07 Voltage Offset Correction: v_off_ini = 790.717 uV, v_off_fin = 782.805 uV 16:27:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.392 uVs 16:27:07 Integrated Voltage Measurement... 16:27:16 Voltage Offset Correction: v_off_ini = 764.434 uV, v_off_fin = 772.342 uV 16:27:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.040 uVs 16:27:16 Integrated Voltage Measurement... 16:27:25 Voltage Offset Correction: v_off_ini = 790.117 uV, v_off_fin = 797.089 uV 16:27:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.671 uVs 16:27:25 Integrated Voltage Measurement... 16:27:34 Voltage Offset Correction: v_off_ini = 782.013 uV, v_off_fin = 783.534 uV 16:27:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.148 uVs 16:27:34 Integrated Voltage Measurement... 16:27:43 Voltage Offset Correction: v_off_ini = 794.240 uV, v_off_fin = 821.659 uV 16:27:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.087 uVs 16:27:47 I1Y Average and RMS of Measurements VT = -188.046 +- 2.279 uVs I1Y = -37.609 +- 0.456 uTm 16:27:50 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:27:53 Integrated Voltage Measurement... 16:28:02 Voltage Offset Correction: v_off_ini = 784.464 uV, v_off_fin = 767.749 uV 16:28:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.530 uVs 16:28:02 Integrated Voltage Measurement... 16:28:11 Voltage Offset Correction: v_off_ini = 788.391 uV, v_off_fin = 803.786 uV 16:28:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.984 uVs 16:28:11 Integrated Voltage Measurement... 16:28:20 Voltage Offset Correction: v_off_ini = 796.103 uV, v_off_fin = 789.932 uV 16:28:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.405 uVs 16:28:20 Integrated Voltage Measurement... 16:28:29 Voltage Offset Correction: v_off_ini = 801.936 uV, v_off_fin = 798.660 uV 16:28:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.490 uVs 16:28:29 Integrated Voltage Measurement... 16:28:38 Voltage Offset Correction: v_off_ini = 789.477 uV, v_off_fin = 794.674 uV 16:28:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.574 uVs 16:28:38 Integrated Voltage Measurement... 16:28:47 Voltage Offset Correction: v_off_ini = 782.488 uV, v_off_fin = 804.168 uV 16:28:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.996 uVs 16:28:49 I2X Average and RMS of Measurements VT = -95.830 +- 9.510 uVs I2X = 8.816 +- 0.875 uTm^2 16:28:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:28:54 Integrated Voltage Measurement... 16:29:03 Voltage Offset Correction: v_off_ini = 792.723 uV, v_off_fin = 799.556 uV 16:29:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.660 uVs 16:29:03 Integrated Voltage Measurement... 16:29:12 Voltage Offset Correction: v_off_ini = 797.423 uV, v_off_fin = 803.783 uV 16:29:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.991 uVs 16:29:12 Integrated Voltage Measurement... 16:29:21 Voltage Offset Correction: v_off_ini = 804.721 uV, v_off_fin = 787.736 uV 16:29:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.176 uVs 16:29:21 Integrated Voltage Measurement... 16:29:30 Voltage Offset Correction: v_off_ini = 812.229 uV, v_off_fin = 797.849 uV 16:29:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.577 uVs 16:29:31 Integrated Voltage Measurement... 16:29:40 Voltage Offset Correction: v_off_ini = 812.784 uV, v_off_fin = 795.272 uV 16:29:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.810 uVs 16:29:40 Integrated Voltage Measurement... 16:29:49 Voltage Offset Correction: v_off_ini = 801.708 uV, v_off_fin = 804.754 uV 16:29:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.136 uVs 16:29:51 I2Y Average and RMS of Measurements VT = -265.392 +- 12.844 uVs I2Y = -24.416 +- 1.182 uTm^2 16:29:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:29:59 Integrated Voltage Measurement... 16:30:08 Voltage Offset Correction: v_off_ini = 827.795 uV, v_off_fin = 822.517 uV 16:30:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.490 uVs 16:30:08 Integrated Voltage Measurement... 16:30:17 Voltage Offset Correction: v_off_ini = 817.855 uV, v_off_fin = 809.536 uV 16:30:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.156 uVs 16:30:17 Integrated Voltage Measurement... 16:30:26 Voltage Offset Correction: v_off_ini = 800.800 uV, v_off_fin = 796.699 uV 16:30:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.745 uVs 16:30:26 Integrated Voltage Measurement... 16:30:35 Voltage Offset Correction: v_off_ini = 819.596 uV, v_off_fin = 803.450 uV 16:30:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.230 uVs 16:30:35 Integrated Voltage Measurement... 16:30:44 Voltage Offset Correction: v_off_ini = 799.863 uV, v_off_fin = 819.642 uV 16:30:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.378 uVs 16:30:45 Integrated Voltage Measurement... 16:30:53 Voltage Offset Correction: v_off_ini = 802.617 uV, v_off_fin = 803.914 uV 16:30:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.166 uVs 16:30:58 I1X Average and RMS of Measurements VT = -100.861 +- 3.918 uVs I1X = 20.172 +- 0.783 uTm 16:31:00 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:31:04 Integrated Voltage Measurement... 16:31:13 Voltage Offset Correction: v_off_ini = 813.808 uV, v_off_fin = 797.883 uV 16:31:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.770 uVs 16:31:14 Integrated Voltage Measurement... 16:31:22 Voltage Offset Correction: v_off_ini = 805.308 uV, v_off_fin = 820.959 uV 16:31:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.708 uVs 16:31:23 Integrated Voltage Measurement... 16:31:31 Voltage Offset Correction: v_off_ini = 802.615 uV, v_off_fin = 800.315 uV 16:31:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.973 uVs 16:31:32 Integrated Voltage Measurement... 16:31:40 Voltage Offset Correction: v_off_ini = 804.798 uV, v_off_fin = 821.042 uV 16:31:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.173 uVs 16:31:41 Integrated Voltage Measurement... 16:31:49 Voltage Offset Correction: v_off_ini = 797.732 uV, v_off_fin = 789.650 uV 16:31:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.451 uVs 16:31:50 Integrated Voltage Measurement... 16:31:58 Voltage Offset Correction: v_off_ini = 797.392 uV, v_off_fin = 831.221 uV 16:31:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.316 uVs 16:32:03 I1Y Average and RMS of Measurements VT = -195.065 +- 8.718 uVs I1Y = -39.013 +- 1.744 uTm 16:32:05 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:32:08 Integrated Voltage Measurement... 16:32:17 Voltage Offset Correction: v_off_ini = 813.915 uV, v_off_fin = 802.300 uV 16:32:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.015 uVs 16:32:17 Integrated Voltage Measurement... 16:32:26 Voltage Offset Correction: v_off_ini = 816.208 uV, v_off_fin = 829.701 uV 16:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.456 uVs 16:32:26 Integrated Voltage Measurement... 16:32:35 Voltage Offset Correction: v_off_ini = 820.342 uV, v_off_fin = 795.307 uV 16:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.790 uVs 16:32:35 Integrated Voltage Measurement... 16:32:44 Voltage Offset Correction: v_off_ini = 805.531 uV, v_off_fin = 809.185 uV 16:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.664 uVs 16:32:44 Integrated Voltage Measurement... 16:32:53 Voltage Offset Correction: v_off_ini = 801.933 uV, v_off_fin = 798.872 uV 16:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.147 uVs 16:32:53 Integrated Voltage Measurement... 16:33:02 Voltage Offset Correction: v_off_ini = 796.480 uV, v_off_fin = 805.373 uV 16:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.709 uVs 16:33:05 I2X Average and RMS of Measurements VT = -104.464 +- 4.033 uVs I2X = 9.611 +- 0.371 uTm^2 16:33:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:33:10 Integrated Voltage Measurement... 16:33:19 Voltage Offset Correction: v_off_ini = 812.507 uV, v_off_fin = 834.389 uV 16:33:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.524 uVs 16:33:19 Integrated Voltage Measurement... 16:33:28 Voltage Offset Correction: v_off_ini = 816.749 uV, v_off_fin = 824.892 uV 16:33:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.369 uVs 16:33:28 Integrated Voltage Measurement... 16:33:37 Voltage Offset Correction: v_off_ini = 815.309 uV, v_off_fin = 813.598 uV 16:33:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.702 uVs 16:33:37 Integrated Voltage Measurement... 16:33:46 Voltage Offset Correction: v_off_ini = 820.518 uV, v_off_fin = 805.149 uV 16:33:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.834 uVs 16:33:46 Integrated Voltage Measurement... 16:33:55 Voltage Offset Correction: v_off_ini = 798.345 uV, v_off_fin = 797.705 uV 16:33:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.190 uVs 16:33:55 Integrated Voltage Measurement... 16:34:04 Voltage Offset Correction: v_off_ini = 797.870 uV, v_off_fin = 813.651 uV 16:34:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.050 uVs 16:34:06 I2Y Average and RMS of Measurements VT = -258.945 +- 6.369 uVs I2Y = -23.823 +- 0.586 uTm^2 16:34:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:34:15 Integrated Voltage Measurement... 16:34:24 Voltage Offset Correction: v_off_ini = 822.615 uV, v_off_fin = 826.787 uV 16:34:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -90.173 uVs 16:34:24 Integrated Voltage Measurement... 16:34:33 Voltage Offset Correction: v_off_ini = 818.754 uV, v_off_fin = 814.014 uV 16:34:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.856 uVs 16:34:33 Integrated Voltage Measurement... 16:34:42 Voltage Offset Correction: v_off_ini = 814.419 uV, v_off_fin = 803.235 uV 16:34:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.604 uVs 16:34:42 Integrated Voltage Measurement... 16:34:51 Voltage Offset Correction: v_off_ini = 808.661 uV, v_off_fin = 814.355 uV 16:34:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.859 uVs 16:34:51 Integrated Voltage Measurement... 16:35:00 Voltage Offset Correction: v_off_ini = 803.017 uV, v_off_fin = 803.792 uV 16:35:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.486 uVs 16:35:00 Integrated Voltage Measurement... 16:35:09 Voltage Offset Correction: v_off_ini = 802.300 uV, v_off_fin = 791.141 uV 16:35:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.108 uVs 16:35:13 I1X Average and RMS of Measurements VT = -85.848 +- 6.858 uVs I1X = 17.170 +- 1.371 uTm 16:35:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:20 Integrated Voltage Measurement... 16:35:29 Voltage Offset Correction: v_off_ini = 813.741 uV, v_off_fin = 791.650 uV 16:35:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.084 uVs 16:35:29 Integrated Voltage Measurement... 16:35:38 Voltage Offset Correction: v_off_ini = 788.288 uV, v_off_fin = 794.706 uV 16:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.070 uVs 16:35:38 Integrated Voltage Measurement... 16:35:47 Voltage Offset Correction: v_off_ini = 784.966 uV, v_off_fin = 766.127 uV 16:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.632 uVs 16:35:47 Integrated Voltage Measurement... 16:35:56 Voltage Offset Correction: v_off_ini = 789.507 uV, v_off_fin = 801.578 uV 16:35:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.270 uVs 16:35:56 Integrated Voltage Measurement... 16:36:05 Voltage Offset Correction: v_off_ini = 793.613 uV, v_off_fin = 800.431 uV 16:36:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.874 uVs 16:36:05 Integrated Voltage Measurement... 16:36:14 Voltage Offset Correction: v_off_ini = 803.842 uV, v_off_fin = 800.829 uV 16:36:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.506 uVs 16:36:18 I1Y Average and RMS of Measurements VT = -190.573 +- 4.946 uVs I1Y = -38.115 +- 0.989 uTm 16:36:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:36:23 Integrated Voltage Measurement... 16:36:32 Voltage Offset Correction: v_off_ini = 804.514 uV, v_off_fin = 793.676 uV 16:36:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.666 uVs 16:36:32 Integrated Voltage Measurement... 16:36:41 Voltage Offset Correction: v_off_ini = 811.526 uV, v_off_fin = 816.470 uV 16:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.008 uVs 16:36:41 Integrated Voltage Measurement... 16:36:50 Voltage Offset Correction: v_off_ini = 822.995 uV, v_off_fin = 804.971 uV 16:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.694 uVs 16:36:50 Integrated Voltage Measurement... 16:36:59 Voltage Offset Correction: v_off_ini = 819.727 uV, v_off_fin = 830.116 uV 16:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.735 uVs 16:36:59 Integrated Voltage Measurement... 16:37:08 Voltage Offset Correction: v_off_ini = 817.441 uV, v_off_fin = 802.731 uV 16:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.680 uVs 16:37:08 Integrated Voltage Measurement... 16:37:17 Voltage Offset Correction: v_off_ini = 813.106 uV, v_off_fin = 807.444 uV 16:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.275 uVs 16:37:20 I2X Average and RMS of Measurements VT = -107.343 +- 5.286 uVs I2X = 9.876 +- 0.486 uTm^2 16:37:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:25 Integrated Voltage Measurement... 16:37:34 Voltage Offset Correction: v_off_ini = 806.121 uV, v_off_fin = 815.745 uV 16:37:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.077 uVs 16:37:34 Integrated Voltage Measurement... 16:37:43 Voltage Offset Correction: v_off_ini = 828.114 uV, v_off_fin = 818.224 uV 16:37:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.558 uVs 16:37:43 Integrated Voltage Measurement... 16:37:52 Voltage Offset Correction: v_off_ini = 796.732 uV, v_off_fin = 803.621 uV 16:37:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.877 uVs 16:37:52 Integrated Voltage Measurement... 16:38:01 Voltage Offset Correction: v_off_ini = 810.915 uV, v_off_fin = 811.369 uV 16:38:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.645 uVs 16:38:01 Integrated Voltage Measurement... 16:38:10 Voltage Offset Correction: v_off_ini = 803.523 uV, v_off_fin = 809.144 uV 16:38:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.441 uVs 16:38:10 Integrated Voltage Measurement... 16:38:19 Voltage Offset Correction: v_off_ini = 806.766 uV, v_off_fin = 781.325 uV 16:38:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.146 uVs 16:38:22 I2Y Average and RMS of Measurements VT = -254.457 +- 3.186 uVs I2Y = -23.410 +- 0.293 uTm^2 16:38:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:38:30 Integrated Voltage Measurement... 16:38:39 Voltage Offset Correction: v_off_ini = 808.686 uV, v_off_fin = 818.903 uV 16:38:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.082 uVs 16:38:39 Integrated Voltage Measurement... 16:38:48 Voltage Offset Correction: v_off_ini = 807.842 uV, v_off_fin = 815.534 uV 16:38:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.767 uVs 16:38:48 Integrated Voltage Measurement... 16:38:57 Voltage Offset Correction: v_off_ini = 821.731 uV, v_off_fin = 810.677 uV 16:38:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.355 uVs 16:38:57 Integrated Voltage Measurement... 16:39:06 Voltage Offset Correction: v_off_ini = 809.705 uV, v_off_fin = 819.878 uV 16:39:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.155 uVs 16:39:06 Integrated Voltage Measurement... 16:39:15 Voltage Offset Correction: v_off_ini = 811.614 uV, v_off_fin = 811.933 uV 16:39:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.415 uVs 16:39:15 Integrated Voltage Measurement... 16:39:24 Voltage Offset Correction: v_off_ini = 819.107 uV, v_off_fin = 838.300 uV 16:39:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.711 uVs 16:39:28 I1X Average and RMS of Measurements VT = -87.581 +- 2.657 uVs I1X = 17.517 +- 0.531 uTm 16:39:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:39:35 Integrated Voltage Measurement... 16:39:44 Voltage Offset Correction: v_off_ini = 826.063 uV, v_off_fin = 821.354 uV 16:39:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.331 uVs 16:39:44 Integrated Voltage Measurement... 16:39:53 Voltage Offset Correction: v_off_ini = 854.858 uV, v_off_fin = 847.705 uV 16:39:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.086 uVs 16:39:53 Integrated Voltage Measurement... 16:40:02 Voltage Offset Correction: v_off_ini = 842.223 uV, v_off_fin = 827.047 uV 16:40:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.232 uVs 16:40:02 Integrated Voltage Measurement... 16:40:11 Voltage Offset Correction: v_off_ini = 843.184 uV, v_off_fin = 841.168 uV 16:40:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.310 uVs 16:40:11 Integrated Voltage Measurement... 16:40:20 Voltage Offset Correction: v_off_ini = 841.357 uV, v_off_fin = 830.253 uV 16:40:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.831 uVs 16:40:20 Integrated Voltage Measurement... 16:40:29 Voltage Offset Correction: v_off_ini = 843.345 uV, v_off_fin = 849.025 uV 16:40:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.136 uVs 16:40:33 I1Y Average and RMS of Measurements VT = -190.988 +- 4.116 uVs I1Y = -38.196 +- 0.822 uTm 16:40:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:40:39 Integrated Voltage Measurement... 16:40:48 Voltage Offset Correction: v_off_ini = 844.149 uV, v_off_fin = 844.119 uV 16:40:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.666 uVs 16:40:48 Integrated Voltage Measurement... 16:40:57 Voltage Offset Correction: v_off_ini = 854.433 uV, v_off_fin = 838.577 uV 16:40:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.606 uVs 16:40:57 Integrated Voltage Measurement... 16:41:06 Voltage Offset Correction: v_off_ini = 851.164 uV, v_off_fin = 828.580 uV 16:41:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.121 uVs 16:41:06 Integrated Voltage Measurement... 16:41:15 Voltage Offset Correction: v_off_ini = 861.620 uV, v_off_fin = 857.069 uV 16:41:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.484 uVs 16:41:15 Integrated Voltage Measurement... 16:41:24 Voltage Offset Correction: v_off_ini = 845.027 uV, v_off_fin = 847.027 uV 16:41:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.699 uVs 16:41:24 Integrated Voltage Measurement... 16:41:33 Voltage Offset Correction: v_off_ini = 859.432 uV, v_off_fin = 836.989 uV 16:41:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.023 uVs 16:41:35 I2X Average and RMS of Measurements VT = -103.600 +- 6.683 uVs I2X = 9.531 +- 0.615 uTm^2 16:41:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:41:40 Integrated Voltage Measurement... 16:41:49 Voltage Offset Correction: v_off_ini = 841.400 uV, v_off_fin = 826.083 uV 16:41:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.469 uVs 16:41:49 Integrated Voltage Measurement... 16:41:58 Voltage Offset Correction: v_off_ini = 832.718 uV, v_off_fin = 847.118 uV 16:41:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.465 uVs 16:41:58 Integrated Voltage Measurement... 16:42:07 Voltage Offset Correction: v_off_ini = 824.842 uV, v_off_fin = 827.080 uV 16:42:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.904 uVs 16:42:07 Integrated Voltage Measurement... 16:42:16 Voltage Offset Correction: v_off_ini = 818.600 uV, v_off_fin = 814.455 uV 16:42:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 250.194 uVs 16:42:17 Integrated Voltage Measurement... 16:42:26 Voltage Offset Correction: v_off_ini = 835.522 uV, v_off_fin = 826.617 uV 16:42:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.618 uVs 16:42:26 Integrated Voltage Measurement... 16:42:35 Voltage Offset Correction: v_off_ini = 804.126 uV, v_off_fin = 805.985 uV 16:42:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.739 uVs 16:42:37 I2Y Average and RMS of Measurements VT = -251.565 +- 3.464 uVs I2Y = -23.144 +- 0.318 uTm^2 16:42:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:42:45 Integrated Voltage Measurement... 16:42:54 Voltage Offset Correction: v_off_ini = 776.559 uV, v_off_fin = 789.170 uV 16:42:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.174 uVs 16:42:54 Integrated Voltage Measurement... 16:43:03 Voltage Offset Correction: v_off_ini = 776.627 uV, v_off_fin = 771.359 uV 16:43:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.865 uVs 16:43:03 Integrated Voltage Measurement... 16:43:12 Voltage Offset Correction: v_off_ini = 789.514 uV, v_off_fin = 786.396 uV 16:43:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.556 uVs 16:43:12 Integrated Voltage Measurement... 16:43:21 Voltage Offset Correction: v_off_ini = 783.509 uV, v_off_fin = 785.171 uV 16:43:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.394 uVs 16:43:21 Integrated Voltage Measurement... 16:43:30 Voltage Offset Correction: v_off_ini = 795.468 uV, v_off_fin = 775.790 uV 16:43:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.141 uVs 16:43:30 Integrated Voltage Measurement... 16:43:39 Voltage Offset Correction: v_off_ini = 789.197 uV, v_off_fin = 792.866 uV 16:43:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.082 uVs 16:43:44 I1X Average and RMS of Measurements VT = -91.202 +- 7.336 uVs I1X = 18.241 +- 1.467 uTm 16:43:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:43:50 Integrated Voltage Measurement... 16:43:59 Voltage Offset Correction: v_off_ini = 776.491 uV, v_off_fin = 761.355 uV 16:43:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -177.513 uVs 16:43:59 Integrated Voltage Measurement... 16:44:08 Voltage Offset Correction: v_off_ini = 779.432 uV, v_off_fin = 795.137 uV 16:44:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.507 uVs 16:44:08 Integrated Voltage Measurement... 16:44:17 Voltage Offset Correction: v_off_ini = 783.593 uV, v_off_fin = 761.585 uV 16:44:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.519 uVs 16:44:17 Integrated Voltage Measurement... 16:44:26 Voltage Offset Correction: v_off_ini = 770.399 uV, v_off_fin = 784.118 uV 16:44:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.748 uVs 16:44:27 Integrated Voltage Measurement... 16:44:35 Voltage Offset Correction: v_off_ini = 784.754 uV, v_off_fin = 761.470 uV 16:44:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.159 uVs 16:44:36 Integrated Voltage Measurement... 16:44:44 Voltage Offset Correction: v_off_ini = 785.660 uV, v_off_fin = 785.937 uV 16:44:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.632 uVs 16:44:49 I1Y Average and RMS of Measurements VT = -194.513 +- 11.132 uVs I1Y = -38.902 +- 2.224 uTm 16:44:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:44:54 Integrated Voltage Measurement... 16:45:03 Voltage Offset Correction: v_off_ini = 778.125 uV, v_off_fin = 784.641 uV 16:45:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.651 uVs 16:45:03 Integrated Voltage Measurement... 16:45:12 Voltage Offset Correction: v_off_ini = 788.977 uV, v_off_fin = 796.335 uV 16:45:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.463 uVs 16:45:12 Integrated Voltage Measurement... 16:45:21 Voltage Offset Correction: v_off_ini = 796.967 uV, v_off_fin = 775.914 uV 16:45:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.221 uVs 16:45:21 Integrated Voltage Measurement... 16:45:30 Voltage Offset Correction: v_off_ini = 782.362 uV, v_off_fin = 769.412 uV 16:45:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.253 uVs 16:45:30 Integrated Voltage Measurement... 16:45:39 Voltage Offset Correction: v_off_ini = 751.225 uV, v_off_fin = 759.864 uV 16:45:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.360 uVs 16:45:39 Integrated Voltage Measurement... 16:45:48 Voltage Offset Correction: v_off_ini = 763.894 uV, v_off_fin = 779.841 uV 16:45:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.290 uVs 16:45:50 I2X Average and RMS of Measurements VT = -94.040 +- 9.007 uVs I2X = 8.652 +- 0.829 uTm^2 16:45:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:45:56 Integrated Voltage Measurement... 16:46:05 Voltage Offset Correction: v_off_ini = 756.790 uV, v_off_fin = 767.917 uV 16:46:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.058 uVs 16:46:05 Integrated Voltage Measurement... 16:46:14 Voltage Offset Correction: v_off_ini = 779.437 uV, v_off_fin = 783.644 uV 16:46:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.263 uVs 16:46:14 Integrated Voltage Measurement... 16:46:23 Voltage Offset Correction: v_off_ini = 776.304 uV, v_off_fin = 763.108 uV 16:46:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.436 uVs 16:46:23 Integrated Voltage Measurement... 16:46:32 Voltage Offset Correction: v_off_ini = 772.388 uV, v_off_fin = 785.294 uV 16:46:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.702 uVs 16:46:32 Integrated Voltage Measurement... 16:46:41 Voltage Offset Correction: v_off_ini = 783.966 uV, v_off_fin = 776.425 uV 16:46:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -273.241 uVs 16:46:41 Integrated Voltage Measurement... 16:46:50 Voltage Offset Correction: v_off_ini = 770.864 uV, v_off_fin = 773.531 uV 16:46:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.825 uVs 16:46:52 I2Y Average and RMS of Measurements VT = -261.254 +- 12.205 uVs I2Y = -24.036 +- 1.123 uTm^2 16:47:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:47:13 Integrated Voltage Measurement... 16:47:22 Voltage Offset Correction: v_off_ini = 761.048 uV, v_off_fin = 764.854 uV 16:47:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.692 uVs 16:47:22 Integrated Voltage Measurement... 16:47:31 Voltage Offset Correction: v_off_ini = 753.425 uV, v_off_fin = 753.359 uV 16:47:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.051 uVs 16:47:31 Integrated Voltage Measurement... 16:47:40 Voltage Offset Correction: v_off_ini = 783.373 uV, v_off_fin = 778.077 uV 16:47:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.221 uVs 16:47:40 Integrated Voltage Measurement... 16:47:49 Voltage Offset Correction: v_off_ini = 771.197 uV, v_off_fin = 748.399 uV 16:47:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.664 uVs 16:47:49 Integrated Voltage Measurement... 16:47:58 Voltage Offset Correction: v_off_ini = 736.171 uV, v_off_fin = 748.835 uV 16:47:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.412 uVs 16:47:58 Integrated Voltage Measurement... 16:48:07 Voltage Offset Correction: v_off_ini = 733.610 uV, v_off_fin = 726.665 uV 16:48:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.815 uVs 16:48:11 I1X Average and RMS of Measurements VT = -89.976 +- 10.176 uVs I1X = 17.995 +- 2.035 uTm 16:48:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:48:18 Integrated Voltage Measurement... 16:48:27 Voltage Offset Correction: v_off_ini = 743.103 uV, v_off_fin = 715.152 uV 16:48:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.847 uVs 16:48:27 Integrated Voltage Measurement... 16:48:36 Voltage Offset Correction: v_off_ini = 738.099 uV, v_off_fin = 748.191 uV 16:48:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.070 uVs 16:48:36 Integrated Voltage Measurement... 16:48:45 Voltage Offset Correction: v_off_ini = 736.024 uV, v_off_fin = 740.041 uV 16:48:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.782 uVs 16:48:45 Integrated Voltage Measurement... 16:48:54 Voltage Offset Correction: v_off_ini = 732.271 uV, v_off_fin = 741.153 uV 16:48:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.860 uVs 16:48:54 Integrated Voltage Measurement... 16:49:03 Voltage Offset Correction: v_off_ini = 749.075 uV, v_off_fin = 738.379 uV 16:49:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.540 uVs 16:49:03 Integrated Voltage Measurement... 16:49:12 Voltage Offset Correction: v_off_ini = 725.558 uV, v_off_fin = 740.169 uV 16:49:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.269 uVs 16:49:16 I1Y Average and RMS of Measurements VT = -206.395 +- 7.369 uVs I1Y = -41.279 +- 1.474 uTm 16:49:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:49:24 Integrated Voltage Measurement... 16:49:33 Voltage Offset Correction: v_off_ini = 719.248 uV, v_off_fin = 715.603 uV 16:49:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.068 uVs 16:49:33 Integrated Voltage Measurement... 16:49:42 Voltage Offset Correction: v_off_ini = 723.094 uV, v_off_fin = 718.110 uV 16:49:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.299 uVs 16:49:42 Integrated Voltage Measurement... 16:49:51 Voltage Offset Correction: v_off_ini = 716.547 uV, v_off_fin = 707.003 uV 16:49:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.284 uVs 16:49:51 Integrated Voltage Measurement... 16:50:00 Voltage Offset Correction: v_off_ini = 722.168 uV, v_off_fin = 735.563 uV 16:50:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.886 uVs 16:50:00 Integrated Voltage Measurement... 16:50:09 Voltage Offset Correction: v_off_ini = 733.932 uV, v_off_fin = 727.490 uV 16:50:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.005 uVs 16:50:09 Integrated Voltage Measurement... 16:50:18 Voltage Offset Correction: v_off_ini = 728.236 uV, v_off_fin = 741.754 uV 16:50:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.503 uVs 16:50:20 I2X Average and RMS of Measurements VT = -105.008 +- 10.248 uVs I2X = 9.661 +- 0.943 uTm^2 16:50:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:50:28 Integrated Voltage Measurement... 16:50:37 Voltage Offset Correction: v_off_ini = 734.757 uV, v_off_fin = 736.316 uV 16:50:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.200 uVs 16:50:37 Integrated Voltage Measurement... 16:50:46 Voltage Offset Correction: v_off_ini = 739.647 uV, v_off_fin = 740.605 uV 16:50:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.416 uVs 16:50:46 Integrated Voltage Measurement... 16:50:55 Voltage Offset Correction: v_off_ini = 746.879 uV, v_off_fin = 742.815 uV 16:50:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.661 uVs 16:50:55 Integrated Voltage Measurement... 16:51:04 Voltage Offset Correction: v_off_ini = 742.694 uV, v_off_fin = 745.497 uV 16:51:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.993 uVs 16:51:04 Integrated Voltage Measurement... 16:51:13 Voltage Offset Correction: v_off_ini = 739.735 uV, v_off_fin = 736.428 uV 16:51:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.204 uVs 16:51:13 Integrated Voltage Measurement... 16:51:22 Voltage Offset Correction: v_off_ini = 723.778 uV, v_off_fin = 759.558 uV 16:51:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.783 uVs 16:51:25 I2Y Average and RMS of Measurements VT = -262.043 +- 1.029 uVs I2Y = -24.108 +- 0.095 uTm^2 16:51:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:51:34 Integrated Voltage Measurement... 16:51:43 Voltage Offset Correction: v_off_ini = 756.933 uV, v_off_fin = 743.941 uV 16:51:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.813 uVs 16:51:43 Integrated Voltage Measurement... 16:51:52 Voltage Offset Correction: v_off_ini = 761.213 uV, v_off_fin = 767.262 uV 16:51:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.448 uVs 16:51:52 Integrated Voltage Measurement... 16:52:01 Voltage Offset Correction: v_off_ini = 759.277 uV, v_off_fin = 752.367 uV 16:52:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.644 uVs 16:52:01 Integrated Voltage Measurement... 16:52:10 Voltage Offset Correction: v_off_ini = 754.384 uV, v_off_fin = 749.290 uV 16:52:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.993 uVs 16:52:10 Integrated Voltage Measurement... 16:52:19 Voltage Offset Correction: v_off_ini = 739.843 uV, v_off_fin = 728.860 uV 16:52:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.176 uVs 16:52:19 Integrated Voltage Measurement... 16:52:28 Voltage Offset Correction: v_off_ini = 735.369 uV, v_off_fin = 723.038 uV 16:52:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.603 uVs 16:52:32 I1X Average and RMS of Measurements VT = -88.446 +- 5.755 uVs I1X = 17.689 +- 1.151 uTm 16:52:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:52:39 Integrated Voltage Measurement... 16:52:48 Voltage Offset Correction: v_off_ini = 745.462 uV, v_off_fin = 714.842 uV 16:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.542 uVs 16:52:48 Integrated Voltage Measurement... 16:52:57 Voltage Offset Correction: v_off_ini = 747.026 uV, v_off_fin = 729.479 uV 16:52:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.610 uVs 16:52:57 Integrated Voltage Measurement... 16:53:06 Voltage Offset Correction: v_off_ini = 728.186 uV, v_off_fin = 730.127 uV 16:53:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.894 uVs 16:53:06 Integrated Voltage Measurement... 16:53:15 Voltage Offset Correction: v_off_ini = 749.847 uV, v_off_fin = 753.591 uV 16:53:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.784 uVs 16:53:15 Integrated Voltage Measurement... 16:53:24 Voltage Offset Correction: v_off_ini = 740.303 uV, v_off_fin = 741.321 uV 16:53:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.293 uVs 16:53:24 Integrated Voltage Measurement... 16:53:33 Voltage Offset Correction: v_off_ini = 740.307 uV, v_off_fin = 740.747 uV 16:53:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.757 uVs 16:53:37 I1Y Average and RMS of Measurements VT = -202.313 +- 2.555 uVs I1Y = -40.463 +- 0.511 uTm 16:53:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:53:45 Integrated Voltage Measurement... 16:53:54 Voltage Offset Correction: v_off_ini = 722.332 uV, v_off_fin = 722.216 uV 16:53:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.946 uVs 16:53:54 Integrated Voltage Measurement... 16:54:03 Voltage Offset Correction: v_off_ini = 723.730 uV, v_off_fin = 741.123 uV 16:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.439 uVs 16:54:03 Integrated Voltage Measurement... 16:54:12 Voltage Offset Correction: v_off_ini = 730.194 uV, v_off_fin = 710.205 uV 16:54:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.357 uVs 16:54:12 Integrated Voltage Measurement... 16:54:21 Voltage Offset Correction: v_off_ini = 723.395 uV, v_off_fin = 733.233 uV 16:54:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.446 uVs 16:54:21 Integrated Voltage Measurement... 16:54:30 Voltage Offset Correction: v_off_ini = 742.601 uV, v_off_fin = 738.486 uV 16:54:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.882 uVs 16:54:30 Integrated Voltage Measurement... 16:54:39 Voltage Offset Correction: v_off_ini = 723.696 uV, v_off_fin = 737.639 uV 16:54:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.381 uVs 16:54:41 I2X Average and RMS of Measurements VT = -96.909 +- 5.420 uVs I2X = 8.916 +- 0.499 uTm^2 16:54:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:54:49 Integrated Voltage Measurement... 16:54:58 Voltage Offset Correction: v_off_ini = 723.259 uV, v_off_fin = 732.985 uV 16:54:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.582 uVs 16:54:58 Integrated Voltage Measurement... 16:55:07 Voltage Offset Correction: v_off_ini = 722.669 uV, v_off_fin = 714.583 uV 16:55:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.898 uVs 16:55:07 Integrated Voltage Measurement... 16:55:16 Voltage Offset Correction: v_off_ini = 715.291 uV, v_off_fin = 737.742 uV 16:55:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.896 uVs 16:55:16 Integrated Voltage Measurement... 16:55:25 Voltage Offset Correction: v_off_ini = 720.676 uV, v_off_fin = 721.979 uV 16:55:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.265 uVs 16:55:25 Integrated Voltage Measurement... 16:55:34 Voltage Offset Correction: v_off_ini = 718.350 uV, v_off_fin = 719.735 uV 16:55:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.759 uVs 16:55:34 Integrated Voltage Measurement... 16:55:43 Voltage Offset Correction: v_off_ini = 734.109 uV, v_off_fin = 730.906 uV 16:55:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.597 uVs 16:55:46 I2Y Average and RMS of Measurements VT = -264.166 +- 2.243 uVs I2Y = -24.303 +- 0.206 uTm^2 16:55:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:55 Integrated Voltage Measurement... 16:56:04 Voltage Offset Correction: v_off_ini = 741.992 uV, v_off_fin = 739.190 uV 16:56:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.391 uVs 16:56:04 Integrated Voltage Measurement... 16:56:13 Voltage Offset Correction: v_off_ini = 739.819 uV, v_off_fin = 742.439 uV 16:56:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.722 uVs 16:56:13 Integrated Voltage Measurement... 16:56:22 Voltage Offset Correction: v_off_ini = 710.762 uV, v_off_fin = 705.011 uV 16:56:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.749 uVs 16:56:22 Integrated Voltage Measurement... 16:56:31 Voltage Offset Correction: v_off_ini = 706.960 uV, v_off_fin = 703.389 uV 16:56:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.812 uVs 16:56:31 Integrated Voltage Measurement... 16:56:40 Voltage Offset Correction: v_off_ini = 709.383 uV, v_off_fin = 708.148 uV 16:56:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.178 uVs 16:56:40 Integrated Voltage Measurement... 16:56:49 Voltage Offset Correction: v_off_ini = 714.997 uV, v_off_fin = 703.867 uV 16:56:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.183 uVs 16:56:53 I1X Average and RMS of Measurements VT = -84.839 +- 7.444 uVs I1X = 16.968 +- 1.489 uTm 16:56:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:00 Integrated Voltage Measurement... 16:57:09 Voltage Offset Correction: v_off_ini = 692.149 uV, v_off_fin = 688.522 uV 16:57:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -184.157 uVs 16:57:09 Integrated Voltage Measurement... 16:57:18 Voltage Offset Correction: v_off_ini = 698.335 uV, v_off_fin = 710.801 uV 16:57:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.721 uVs 16:57:18 Integrated Voltage Measurement... 16:57:27 Voltage Offset Correction: v_off_ini = 716.956 uV, v_off_fin = 703.494 uV 16:57:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.960 uVs 16:57:27 Integrated Voltage Measurement... 16:57:36 Voltage Offset Correction: v_off_ini = 702.027 uV, v_off_fin = 730.843 uV 16:57:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.544 uVs 16:57:36 Integrated Voltage Measurement... 16:57:45 Voltage Offset Correction: v_off_ini = 710.821 uV, v_off_fin = 685.957 uV 16:57:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.117 uVs 16:57:45 Integrated Voltage Measurement... 16:57:54 Voltage Offset Correction: v_off_ini = 692.823 uV, v_off_fin = 710.585 uV 16:57:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.797 uVs 16:57:58 I1Y Average and RMS of Measurements VT = -196.049 +- 4.924 uVs I1Y = -39.210 +- 0.984 uTm 16:58:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:06 Integrated Voltage Measurement... 16:58:15 Voltage Offset Correction: v_off_ini = 708.899 uV, v_off_fin = 709.941 uV 16:58:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -80.926 uVs 16:58:15 Integrated Voltage Measurement... 16:58:24 Voltage Offset Correction: v_off_ini = 738.663 uV, v_off_fin = 705.700 uV 16:58:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.835 uVs 16:58:24 Integrated Voltage Measurement... 16:58:33 Voltage Offset Correction: v_off_ini = 714.719 uV, v_off_fin = 722.589 uV 16:58:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.029 uVs 16:58:33 Integrated Voltage Measurement... 16:58:42 Voltage Offset Correction: v_off_ini = 715.733 uV, v_off_fin = 727.473 uV 16:58:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.844 uVs 16:58:42 Integrated Voltage Measurement... 16:58:51 Voltage Offset Correction: v_off_ini = 690.713 uV, v_off_fin = 700.937 uV 16:58:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.185 uVs 16:58:51 Integrated Voltage Measurement... 16:59:00 Voltage Offset Correction: v_off_ini = 701.930 uV, v_off_fin = 717.369 uV 16:59:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.685 uVs 16:59:03 I2X Average and RMS of Measurements VT = -90.084 +- 13.089 uVs I2X = 8.288 +- 1.204 uTm^2 16:59:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:10 Integrated Voltage Measurement... 16:59:19 Voltage Offset Correction: v_off_ini = 683.796 uV, v_off_fin = 688.125 uV 16:59:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.938 uVs 16:59:19 Integrated Voltage Measurement... 16:59:28 Voltage Offset Correction: v_off_ini = 704.264 uV, v_off_fin = 718.145 uV 16:59:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.159 uVs 16:59:28 Integrated Voltage Measurement... 16:59:37 Voltage Offset Correction: v_off_ini = 702.764 uV, v_off_fin = 709.193 uV 16:59:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.744 uVs 16:59:37 Integrated Voltage Measurement... 16:59:46 Voltage Offset Correction: v_off_ini = 718.027 uV, v_off_fin = 707.113 uV 16:59:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.071 uVs 16:59:47 Integrated Voltage Measurement... 16:59:56 Voltage Offset Correction: v_off_ini = 700.102 uV, v_off_fin = 698.376 uV 16:59:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.261 uVs 16:59:56 Integrated Voltage Measurement... 17:00:05 Voltage Offset Correction: v_off_ini = 712.166 uV, v_off_fin = 696.359 uV 17:00:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.020 uVs 17:00:07 I2Y Average and RMS of Measurements VT = -255.366 +- 2.775 uVs I2Y = -23.494 +- 0.255 uTm^2 17:00:12 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:00:16 Integrated Voltage Measurement... 17:00:25 Voltage Offset Correction: v_off_ini = 727.715 uV, v_off_fin = 713.770 uV 17:00:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.614 uVs 17:00:25 Integrated Voltage Measurement... 17:00:34 Voltage Offset Correction: v_off_ini = 718.711 uV, v_off_fin = 728.565 uV 17:00:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.317 uVs 17:00:34 Integrated Voltage Measurement... 17:00:43 Voltage Offset Correction: v_off_ini = 717.216 uV, v_off_fin = 723.771 uV 17:00:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.851 uVs 17:00:43 Integrated Voltage Measurement... 17:00:52 Voltage Offset Correction: v_off_ini = 736.978 uV, v_off_fin = 714.753 uV 17:00:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.724 uVs 17:00:52 Integrated Voltage Measurement... 17:01:01 Voltage Offset Correction: v_off_ini = 710.223 uV, v_off_fin = 710.777 uV 17:01:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.682 uVs 17:01:01 Integrated Voltage Measurement... 17:01:10 Voltage Offset Correction: v_off_ini = 712.918 uV, v_off_fin = 716.817 uV 17:01:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.939 uVs 17:01:14 I1X Average and RMS of Measurements VT = -82.521 +- 11.079 uVs I1X = 16.504 +- 2.216 uTm 17:01:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:01:21 Integrated Voltage Measurement... 17:01:30 Voltage Offset Correction: v_off_ini = 712.286 uV, v_off_fin = 711.609 uV 17:01:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.372 uVs 17:01:30 Integrated Voltage Measurement... 17:01:39 Voltage Offset Correction: v_off_ini = 707.130 uV, v_off_fin = 749.213 uV 17:01:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.635 uVs 17:01:39 Integrated Voltage Measurement... 17:01:48 Voltage Offset Correction: v_off_ini = 719.959 uV, v_off_fin = 706.984 uV 17:01:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.266 uVs 17:01:48 Integrated Voltage Measurement... 17:01:57 Voltage Offset Correction: v_off_ini = 740.218 uV, v_off_fin = 749.541 uV 17:01:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.763 uVs 17:01:57 Integrated Voltage Measurement... 17:02:06 Voltage Offset Correction: v_off_ini = 735.648 uV, v_off_fin = 729.577 uV 17:02:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.899 uVs 17:02:06 Integrated Voltage Measurement... 17:02:15 Voltage Offset Correction: v_off_ini = 724.385 uV, v_off_fin = 725.471 uV 17:02:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.268 uVs 17:02:19 I1Y Average and RMS of Measurements VT = -198.701 +- 8.172 uVs I1Y = -39.740 +- 1.634 uTm 17:02:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:02:27 Integrated Voltage Measurement... 17:02:36 Voltage Offset Correction: v_off_ini = 709.904 uV, v_off_fin = 700.545 uV 17:02:36 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -100.158 uVs 17:02:36 Integrated Voltage Measurement... 17:02:45 Voltage Offset Correction: v_off_ini = 694.072 uV, v_off_fin = 712.442 uV 17:02:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.427 uVs 17:02:45 Integrated Voltage Measurement... 17:02:54 Voltage Offset Correction: v_off_ini = 703.450 uV, v_off_fin = 698.961 uV 17:02:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.838 uVs 17:02:54 Integrated Voltage Measurement... 17:03:03 Voltage Offset Correction: v_off_ini = 707.051 uV, v_off_fin = 705.741 uV 17:03:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.242 uVs 17:03:03 Integrated Voltage Measurement... 17:03:12 Voltage Offset Correction: v_off_ini = 707.711 uV, v_off_fin = 691.265 uV 17:03:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.420 uVs 17:03:12 Integrated Voltage Measurement... 17:03:21 Voltage Offset Correction: v_off_ini = 698.444 uV, v_off_fin = 700.400 uV 17:03:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.151 uVs 17:03:24 I2X Average and RMS of Measurements VT = -97.706 +- 3.229 uVs I2X = 8.989 +- 0.297 uTm^2 17:03:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:03:31 Integrated Voltage Measurement... 17:03:40 Voltage Offset Correction: v_off_ini = 706.901 uV, v_off_fin = 709.066 uV 17:03:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.468 uVs 17:03:40 Integrated Voltage Measurement... 17:03:49 Voltage Offset Correction: v_off_ini = 719.985 uV, v_off_fin = 717.822 uV 17:03:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.352 uVs 17:03:50 Integrated Voltage Measurement... 17:03:58 Voltage Offset Correction: v_off_ini = 697.678 uV, v_off_fin = 681.234 uV 17:03:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.812 uVs 17:03:59 Integrated Voltage Measurement... 17:04:08 Voltage Offset Correction: v_off_ini = 698.590 uV, v_off_fin = 683.789 uV 17:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.082 uVs 17:04:08 Integrated Voltage Measurement... 17:04:17 Voltage Offset Correction: v_off_ini = 703.875 uV, v_off_fin = 684.658 uV 17:04:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -269.332 uVs 17:04:17 Integrated Voltage Measurement... 17:04:26 Voltage Offset Correction: v_off_ini = 683.261 uV, v_off_fin = 721.636 uV 17:04:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.784 uVs 17:04:28 I2Y Average and RMS of Measurements VT = -260.972 +- 7.019 uVs I2Y = -24.010 +- 0.646 uTm^2 17:04:33 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:04:37 Integrated Voltage Measurement... 17:04:46 Voltage Offset Correction: v_off_ini = 726.450 uV, v_off_fin = 720.091 uV 17:04:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.137 uVs 17:04:46 Integrated Voltage Measurement... 17:04:55 Voltage Offset Correction: v_off_ini = 721.095 uV, v_off_fin = 726.447 uV 17:04:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.697 uVs 17:04:55 Integrated Voltage Measurement... 17:05:04 Voltage Offset Correction: v_off_ini = 722.804 uV, v_off_fin = 721.017 uV 17:05:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.014 uVs 17:05:04 Integrated Voltage Measurement... 17:05:13 Voltage Offset Correction: v_off_ini = 722.245 uV, v_off_fin = 713.532 uV 17:05:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.989 uVs 17:05:13 Integrated Voltage Measurement... 17:05:22 Voltage Offset Correction: v_off_ini = 710.927 uV, v_off_fin = 731.889 uV 17:05:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.489 uVs 17:05:22 Integrated Voltage Measurement... 17:05:31 Voltage Offset Correction: v_off_ini = 721.927 uV, v_off_fin = 716.984 uV 17:05:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.066 uVs 17:05:35 I1X Average and RMS of Measurements VT = -91.232 +- 4.753 uVs I1X = 18.247 +- 0.951 uTm 17:05:38 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:05:42 Integrated Voltage Measurement... 17:05:51 Voltage Offset Correction: v_off_ini = 699.736 uV, v_off_fin = 694.919 uV 17:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.728 uVs 17:05:51 Integrated Voltage Measurement... 17:06:00 Voltage Offset Correction: v_off_ini = 708.288 uV, v_off_fin = 729.445 uV 17:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.270 uVs 17:06:00 Integrated Voltage Measurement... 17:06:09 Voltage Offset Correction: v_off_ini = 730.952 uV, v_off_fin = 716.940 uV 17:06:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.711 uVs 17:06:09 Integrated Voltage Measurement... 17:06:18 Voltage Offset Correction: v_off_ini = 714.718 uV, v_off_fin = 710.842 uV 17:06:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.856 uVs 17:06:18 Integrated Voltage Measurement... 17:06:27 Voltage Offset Correction: v_off_ini = 708.836 uV, v_off_fin = 711.326 uV 17:06:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.588 uVs 17:06:27 Integrated Voltage Measurement... 17:06:36 Voltage Offset Correction: v_off_ini = 724.692 uV, v_off_fin = 743.464 uV 17:06:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.079 uVs 17:06:40 I1Y Average and RMS of Measurements VT = -197.039 +- 5.673 uVs I1Y = -39.408 +- 1.135 uTm 17:06:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:06:48 Integrated Voltage Measurement... 17:06:57 Voltage Offset Correction: v_off_ini = 725.337 uV, v_off_fin = 728.553 uV 17:06:57 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -78.479 uVs 17:06:57 Integrated Voltage Measurement... 17:07:06 Voltage Offset Correction: v_off_ini = 744.324 uV, v_off_fin = 752.369 uV 17:07:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.440 uVs 17:07:06 Integrated Voltage Measurement... 17:07:15 Voltage Offset Correction: v_off_ini = 730.045 uV, v_off_fin = 738.356 uV 17:07:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.124 uVs 17:07:15 Integrated Voltage Measurement... 17:07:24 Voltage Offset Correction: v_off_ini = 748.954 uV, v_off_fin = 749.888 uV 17:07:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.264 uVs 17:07:24 Integrated Voltage Measurement... 17:07:33 Voltage Offset Correction: v_off_ini = 722.571 uV, v_off_fin = 740.142 uV 17:07:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.548 uVs 17:07:33 Integrated Voltage Measurement... 17:07:42 Voltage Offset Correction: v_off_ini = 748.717 uV, v_off_fin = 747.648 uV 17:07:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.757 uVs 17:07:45 I2X Average and RMS of Measurements VT = -85.602 +- 3.443 uVs I2X = 7.875 +- 0.317 uTm^2 17:07:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:07:53 Integrated Voltage Measurement... 17:08:02 Voltage Offset Correction: v_off_ini = 739.251 uV, v_off_fin = 736.867 uV 17:08:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.377 uVs 17:08:02 Integrated Voltage Measurement... 17:08:11 Voltage Offset Correction: v_off_ini = 744.003 uV, v_off_fin = 746.485 uV 17:08:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.832 uVs 17:08:11 Integrated Voltage Measurement... 17:08:20 Voltage Offset Correction: v_off_ini = 727.948 uV, v_off_fin = 732.546 uV 17:08:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.450 uVs 17:08:20 Integrated Voltage Measurement... 17:08:29 Voltage Offset Correction: v_off_ini = 729.086 uV, v_off_fin = 733.669 uV 17:08:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.164 uVs 17:08:29 Integrated Voltage Measurement... 17:08:38 Voltage Offset Correction: v_off_ini = 745.774 uV, v_off_fin = 727.143 uV 17:08:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.475 uVs 17:08:38 Integrated Voltage Measurement... 17:08:47 Voltage Offset Correction: v_off_ini = 740.360 uV, v_off_fin = 738.153 uV 17:08:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.160 uVs 17:08:49 I2Y Average and RMS of Measurements VT = -254.243 +- 2.048 uVs I2Y = -23.390 +- 0.188 uTm^2 17:08:57 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:09:01 Integrated Voltage Measurement... 17:09:10 Voltage Offset Correction: v_off_ini = 742.142 uV, v_off_fin = 757.535 uV 17:09:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -60.595 uVs 17:09:10 Integrated Voltage Measurement... 17:09:19 Voltage Offset Correction: v_off_ini = 777.662 uV, v_off_fin = 761.634 uV 17:09:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.956 uVs 17:09:19 Integrated Voltage Measurement... 17:09:28 Voltage Offset Correction: v_off_ini = 765.203 uV, v_off_fin = 760.085 uV 17:09:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.030 uVs 17:09:28 Integrated Voltage Measurement... 17:09:37 Voltage Offset Correction: v_off_ini = 752.407 uV, v_off_fin = 750.952 uV 17:09:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.674 uVs 17:09:37 Integrated Voltage Measurement... 17:09:46 Voltage Offset Correction: v_off_ini = 767.713 uV, v_off_fin = 752.422 uV 17:09:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.194 uVs 17:09:46 Integrated Voltage Measurement... 17:09:55 Voltage Offset Correction: v_off_ini = 748.059 uV, v_off_fin = 758.165 uV 17:09:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.590 uVs 17:10:00 I1X Average and RMS of Measurements VT = -80.173 +- 4.003 uVs I1X = 16.035 +- 0.800 uTm 17:10:02 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:10:06 Integrated Voltage Measurement... 17:10:15 Voltage Offset Correction: v_off_ini = 748.486 uV, v_off_fin = 747.151 uV 17:10:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.692 uVs 17:10:15 Integrated Voltage Measurement... 17:10:24 Voltage Offset Correction: v_off_ini = 743.502 uV, v_off_fin = 766.720 uV 17:10:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.492 uVs 17:10:24 Integrated Voltage Measurement... 17:10:33 Voltage Offset Correction: v_off_ini = 756.959 uV, v_off_fin = 729.296 uV 17:10:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.215 uVs 17:10:33 Integrated Voltage Measurement... 17:10:42 Voltage Offset Correction: v_off_ini = 759.388 uV, v_off_fin = 762.255 uV 17:10:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.827 uVs 17:10:42 Integrated Voltage Measurement... 17:10:51 Voltage Offset Correction: v_off_ini = 734.389 uV, v_off_fin = 719.954 uV 17:10:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.625 uVs 17:10:51 Integrated Voltage Measurement... 17:11:00 Voltage Offset Correction: v_off_ini = 737.346 uV, v_off_fin = 749.312 uV 17:11:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.345 uVs 17:11:05 I1Y Average and RMS of Measurements VT = -201.366 +- 8.679 uVs I1Y = -40.274 +- 1.736 uTm 17:11:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:11:10 Integrated Voltage Measurement... 17:11:19 Voltage Offset Correction: v_off_ini = 744.171 uV, v_off_fin = 735.181 uV 17:11:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.506 uVs 17:11:19 Integrated Voltage Measurement... 17:11:28 Voltage Offset Correction: v_off_ini = 744.652 uV, v_off_fin = 752.665 uV 17:11:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.583 uVs 17:11:28 Integrated Voltage Measurement... 17:11:37 Voltage Offset Correction: v_off_ini = 746.250 uV, v_off_fin = 732.655 uV 17:11:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.180 uVs 17:11:37 Integrated Voltage Measurement... 17:11:46 Voltage Offset Correction: v_off_ini = 743.512 uV, v_off_fin = 755.290 uV 17:11:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.522 uVs 17:11:46 Integrated Voltage Measurement... 17:11:55 Voltage Offset Correction: v_off_ini = 747.053 uV, v_off_fin = 733.012 uV 17:11:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.784 uVs 17:11:55 Integrated Voltage Measurement... 17:12:04 Voltage Offset Correction: v_off_ini = 762.349 uV, v_off_fin = 740.165 uV 17:12:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.922 uVs 17:12:06 I2X Average and RMS of Measurements VT = -93.583 +- 10.931 uVs I2X = 8.610 +- 1.006 uTm^2 17:12:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:12:12 Integrated Voltage Measurement... 17:12:21 Voltage Offset Correction: v_off_ini = 750.636 uV, v_off_fin = 735.993 uV 17:12:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.469 uVs 17:12:21 Integrated Voltage Measurement... 17:12:30 Voltage Offset Correction: v_off_ini = 744.957 uV, v_off_fin = 752.619 uV 17:12:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.039 uVs 17:12:30 Integrated Voltage Measurement... 17:12:39 Voltage Offset Correction: v_off_ini = 765.988 uV, v_off_fin = 766.455 uV 17:12:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.424 uVs 17:12:39 Integrated Voltage Measurement... 17:12:48 Voltage Offset Correction: v_off_ini = 747.270 uV, v_off_fin = 749.815 uV 17:12:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.190 uVs 17:12:48 Integrated Voltage Measurement... 17:12:57 Voltage Offset Correction: v_off_ini = 750.704 uV, v_off_fin = 731.727 uV 17:12:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.511 uVs 17:12:57 Integrated Voltage Measurement... 17:13:06 Voltage Offset Correction: v_off_ini = 730.776 uV, v_off_fin = 731.958 uV 17:13:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.620 uVs 17:13:08 I2Y Average and RMS of Measurements VT = -259.209 +- 5.699 uVs I2Y = -23.847 +- 0.524 uTm^2 17:13:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:13:17 Integrated Voltage Measurement... 17:13:26 Voltage Offset Correction: v_off_ini = 741.291 uV, v_off_fin = 757.617 uV 17:13:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -84.175 uVs 17:13:26 Integrated Voltage Measurement... 17:13:35 Voltage Offset Correction: v_off_ini = 723.187 uV, v_off_fin = 733.729 uV 17:13:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.825 uVs 17:13:35 Integrated Voltage Measurement... 17:13:44 Voltage Offset Correction: v_off_ini = 720.502 uV, v_off_fin = 730.021 uV 17:13:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.571 uVs 17:13:44 Integrated Voltage Measurement... 17:13:53 Voltage Offset Correction: v_off_ini = 716.662 uV, v_off_fin = 735.182 uV 17:13:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.235 uVs 17:13:53 Integrated Voltage Measurement... 17:14:02 Voltage Offset Correction: v_off_ini = 740.991 uV, v_off_fin = 747.575 uV 17:14:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.925 uVs 17:14:02 Integrated Voltage Measurement... 17:14:11 Voltage Offset Correction: v_off_ini = 754.943 uV, v_off_fin = 759.915 uV 17:14:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.697 uVs 17:14:15 I1X Average and RMS of Measurements VT = -84.238 +- 9.519 uVs I1X = 16.848 +- 1.904 uTm 17:14:17 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:14:22 Integrated Voltage Measurement... 17:14:31 Voltage Offset Correction: v_off_ini = 746.737 uV, v_off_fin = 734.911 uV 17:14:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.259 uVs 17:14:31 Integrated Voltage Measurement... 17:14:40 Voltage Offset Correction: v_off_ini = 759.123 uV, v_off_fin = 739.092 uV 17:14:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.346 uVs 17:14:40 Integrated Voltage Measurement... 17:14:49 Voltage Offset Correction: v_off_ini = 733.088 uV, v_off_fin = 719.370 uV 17:14:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.818 uVs 17:14:49 Integrated Voltage Measurement... 17:14:58 Voltage Offset Correction: v_off_ini = 744.602 uV, v_off_fin = 739.786 uV 17:14:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.677 uVs 17:14:58 Integrated Voltage Measurement... 17:15:07 Voltage Offset Correction: v_off_ini = 714.486 uV, v_off_fin = 713.739 uV 17:15:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.783 uVs 17:15:07 Integrated Voltage Measurement... 17:15:16 Voltage Offset Correction: v_off_ini = 704.812 uV, v_off_fin = 728.940 uV 17:15:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.838 uVs 17:15:20 I1Y Average and RMS of Measurements VT = -192.954 +- 4.055 uVs I1Y = -38.591 +- 0.811 uTm 17:15:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:15:25 Integrated Voltage Measurement... 17:15:34 Voltage Offset Correction: v_off_ini = 730.882 uV, v_off_fin = 727.619 uV 17:15:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.065 uVs 17:15:34 Integrated Voltage Measurement... 17:15:43 Voltage Offset Correction: v_off_ini = 734.353 uV, v_off_fin = 724.432 uV 17:15:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.458 uVs 17:15:43 Integrated Voltage Measurement... 17:15:52 Voltage Offset Correction: v_off_ini = 717.888 uV, v_off_fin = 717.263 uV 17:15:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.945 uVs 17:15:52 Integrated Voltage Measurement... 17:16:01 Voltage Offset Correction: v_off_ini = 719.433 uV, v_off_fin = 711.647 uV 17:16:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.595 uVs 17:16:01 Integrated Voltage Measurement... 17:16:10 Voltage Offset Correction: v_off_ini = 688.975 uV, v_off_fin = 685.608 uV 17:16:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.459 uVs 17:16:10 Integrated Voltage Measurement... 17:16:19 Voltage Offset Correction: v_off_ini = 693.368 uV, v_off_fin = 707.750 uV 17:16:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.224 uVs 17:16:22 I2X Average and RMS of Measurements VT = -102.791 +- 10.024 uVs I2X = 9.457 +- 0.922 uTm^2 17:16:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:16:27 Integrated Voltage Measurement... 17:16:36 Voltage Offset Correction: v_off_ini = 719.709 uV, v_off_fin = 721.313 uV 17:16:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -264.176 uVs 17:16:36 Integrated Voltage Measurement... 17:16:45 Voltage Offset Correction: v_off_ini = 717.693 uV, v_off_fin = 720.131 uV 17:16:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.268 uVs 17:16:45 Integrated Voltage Measurement... 17:16:54 Voltage Offset Correction: v_off_ini = 708.814 uV, v_off_fin = 708.364 uV 17:16:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.864 uVs 17:16:54 Integrated Voltage Measurement... 17:17:03 Voltage Offset Correction: v_off_ini = 708.007 uV, v_off_fin = 723.967 uV 17:17:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.539 uVs 17:17:03 Integrated Voltage Measurement... 17:17:12 Voltage Offset Correction: v_off_ini = 718.139 uV, v_off_fin = 715.487 uV 17:17:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.094 uVs 17:17:12 Integrated Voltage Measurement... 17:17:21 Voltage Offset Correction: v_off_ini = 722.599 uV, v_off_fin = 724.051 uV 17:17:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.842 uVs 17:17:23 I2Y Average and RMS of Measurements VT = -262.631 +- 2.133 uVs I2Y = -24.162 +- 0.196 uTm^2 17:17:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:17:32 Integrated Voltage Measurement... 17:17:41 Voltage Offset Correction: v_off_ini = 732.401 uV, v_off_fin = 738.612 uV 17:17:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.313 uVs 17:17:41 Integrated Voltage Measurement... 17:17:50 Voltage Offset Correction: v_off_ini = 732.076 uV, v_off_fin = 738.377 uV 17:17:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.908 uVs 17:17:50 Integrated Voltage Measurement... 17:17:59 Voltage Offset Correction: v_off_ini = 710.008 uV, v_off_fin = 696.978 uV 17:17:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.447 uVs 17:17:59 Integrated Voltage Measurement... 17:18:08 Voltage Offset Correction: v_off_ini = 705.704 uV, v_off_fin = 698.978 uV 17:18:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.406 uVs 17:18:08 Integrated Voltage Measurement... 17:18:17 Voltage Offset Correction: v_off_ini = 689.093 uV, v_off_fin = 715.504 uV 17:18:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.781 uVs 17:18:17 Integrated Voltage Measurement... 17:18:26 Voltage Offset Correction: v_off_ini = 691.317 uV, v_off_fin = 709.228 uV 17:18:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.158 uVs 17:18:30 I1X Average and RMS of Measurements VT = -84.002 +- 9.787 uVs I1X = 16.801 +- 1.957 uTm 17:18:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:18:37 Integrated Voltage Measurement... 17:18:46 Voltage Offset Correction: v_off_ini = 707.058 uV, v_off_fin = 694.025 uV 17:18:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.264 uVs 17:18:46 Integrated Voltage Measurement... 17:18:55 Voltage Offset Correction: v_off_ini = 695.420 uV, v_off_fin = 711.589 uV 17:18:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.572 uVs 17:18:55 Integrated Voltage Measurement... 17:19:04 Voltage Offset Correction: v_off_ini = 690.745 uV, v_off_fin = 702.771 uV 17:19:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.758 uVs 17:19:04 Integrated Voltage Measurement... 17:19:13 Voltage Offset Correction: v_off_ini = 729.215 uV, v_off_fin = 736.811 uV 17:19:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.345 uVs 17:19:13 Integrated Voltage Measurement... 17:19:22 Voltage Offset Correction: v_off_ini = 731.261 uV, v_off_fin = 725.592 uV 17:19:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.785 uVs 17:19:22 Integrated Voltage Measurement... 17:19:31 Voltage Offset Correction: v_off_ini = 721.144 uV, v_off_fin = 725.065 uV 17:19:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.962 uVs 17:19:35 I1Y Average and RMS of Measurements VT = -191.614 +- 6.396 uVs I1Y = -38.321 +- 1.280 uTm 17:19:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:40 Integrated Voltage Measurement... 17:19:49 Voltage Offset Correction: v_off_ini = 726.178 uV, v_off_fin = 716.549 uV 17:19:49 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -112.727 uVs 17:19:49 Integrated Voltage Measurement... 17:19:58 Voltage Offset Correction: v_off_ini = 716.412 uV, v_off_fin = 724.465 uV 17:19:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.923 uVs 17:19:58 Integrated Voltage Measurement... 17:20:07 Voltage Offset Correction: v_off_ini = 725.642 uV, v_off_fin = 721.881 uV 17:20:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.117 uVs 17:20:07 Integrated Voltage Measurement... 17:20:16 Voltage Offset Correction: v_off_ini = 692.013 uV, v_off_fin = 704.003 uV 17:20:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.579 uVs 17:20:17 Integrated Voltage Measurement... 17:20:26 Voltage Offset Correction: v_off_ini = 719.916 uV, v_off_fin = 703.756 uV 17:20:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.651 uVs 17:20:26 Integrated Voltage Measurement... 17:20:35 Voltage Offset Correction: v_off_ini = 712.012 uV, v_off_fin = 726.891 uV 17:20:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.873 uVs 17:20:37 I2X Average and RMS of Measurements VT = -108.478 +- 10.986 uVs I2X = 9.980 +- 1.011 uTm^2 17:20:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:42 Integrated Voltage Measurement... 17:20:51 Voltage Offset Correction: v_off_ini = 710.723 uV, v_off_fin = 705.447 uV 17:20:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.810 uVs 17:20:51 Integrated Voltage Measurement... 17:21:00 Voltage Offset Correction: v_off_ini = 689.785 uV, v_off_fin = 695.832 uV 17:21:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.410 uVs 17:21:00 Integrated Voltage Measurement... 17:21:09 Voltage Offset Correction: v_off_ini = 694.243 uV, v_off_fin = 705.116 uV 17:21:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.341 uVs 17:21:09 Integrated Voltage Measurement... 17:21:18 Voltage Offset Correction: v_off_ini = 701.939 uV, v_off_fin = 689.109 uV 17:21:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.336 uVs 17:21:18 Integrated Voltage Measurement... 17:21:27 Voltage Offset Correction: v_off_ini = 686.370 uV, v_off_fin = 683.285 uV 17:21:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -271.089 uVs 17:21:27 Integrated Voltage Measurement... 17:21:36 Voltage Offset Correction: v_off_ini = 682.676 uV, v_off_fin = 686.876 uV 17:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.699 uVs 17:21:39 I2Y Average and RMS of Measurements VT = -261.781 +- 8.494 uVs I2Y = -24.084 +- 0.782 uTm^2 17:21:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:21:47 Integrated Voltage Measurement... 17:21:56 Voltage Offset Correction: v_off_ini = 705.503 uV, v_off_fin = 697.882 uV 17:21:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.013 uVs 17:21:56 Integrated Voltage Measurement... 17:22:05 Voltage Offset Correction: v_off_ini = 690.859 uV, v_off_fin = 691.248 uV 17:22:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.947 uVs 17:22:05 Integrated Voltage Measurement... 17:22:14 Voltage Offset Correction: v_off_ini = 700.314 uV, v_off_fin = 698.855 uV 17:22:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.918 uVs 17:22:14 Integrated Voltage Measurement... 17:22:23 Voltage Offset Correction: v_off_ini = 666.442 uV, v_off_fin = 693.283 uV 17:22:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.698 uVs 17:22:23 Integrated Voltage Measurement... 17:22:32 Voltage Offset Correction: v_off_ini = 695.593 uV, v_off_fin = 683.824 uV 17:22:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.359 uVs 17:22:32 Integrated Voltage Measurement... 17:22:41 Voltage Offset Correction: v_off_ini = 681.821 uV, v_off_fin = 684.091 uV 17:22:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.282 uVs 17:22:45 I1X Average and RMS of Measurements VT = -92.870 +- 8.776 uVs I1X = 18.574 +- 1.755 uTm 17:22:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:22:52 Integrated Voltage Measurement... 17:23:01 Voltage Offset Correction: v_off_ini = 683.035 uV, v_off_fin = 691.666 uV 17:23:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.349 uVs 17:23:01 Integrated Voltage Measurement... 17:23:10 Voltage Offset Correction: v_off_ini = 690.694 uV, v_off_fin = 704.193 uV 17:23:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.412 uVs 17:23:10 Integrated Voltage Measurement... 17:23:19 Voltage Offset Correction: v_off_ini = 691.812 uV, v_off_fin = 677.724 uV 17:23:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.376 uVs 17:23:19 Integrated Voltage Measurement... 17:23:28 Voltage Offset Correction: v_off_ini = 693.457 uV, v_off_fin = 709.135 uV 17:23:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.283 uVs 17:23:28 Integrated Voltage Measurement... 17:23:37 Voltage Offset Correction: v_off_ini = 673.836 uV, v_off_fin = 669.296 uV 17:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.695 uVs 17:23:37 Integrated Voltage Measurement... 17:23:46 Voltage Offset Correction: v_off_ini = 689.163 uV, v_off_fin = 691.843 uV 17:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.817 uVs 17:23:51 I1Y Average and RMS of Measurements VT = -199.155 +- 9.631 uVs I1Y = -39.828 +- 1.926 uTm 17:23:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:23:56 Integrated Voltage Measurement... 17:24:05 Voltage Offset Correction: v_off_ini = 697.205 uV, v_off_fin = 702.936 uV 17:24:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.163 uVs 17:24:05 Integrated Voltage Measurement... 17:24:14 Voltage Offset Correction: v_off_ini = 727.033 uV, v_off_fin = 734.216 uV 17:24:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.986 uVs 17:24:14 Integrated Voltage Measurement... 17:24:23 Voltage Offset Correction: v_off_ini = 705.183 uV, v_off_fin = 688.898 uV 17:24:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.072 uVs 17:24:23 Integrated Voltage Measurement... 17:24:32 Voltage Offset Correction: v_off_ini = 703.939 uV, v_off_fin = 707.384 uV 17:24:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.378 uVs 17:24:32 Integrated Voltage Measurement... 17:24:41 Voltage Offset Correction: v_off_ini = 702.332 uV, v_off_fin = 696.812 uV 17:24:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.267 uVs 17:24:41 Integrated Voltage Measurement... 17:24:50 Voltage Offset Correction: v_off_ini = 700.096 uV, v_off_fin = 715.843 uV 17:24:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.504 uVs 17:24:52 I2X Average and RMS of Measurements VT = -85.062 +- 4.187 uVs I2X = 7.826 +- 0.385 uTm^2 17:24:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:24:57 Integrated Voltage Measurement... 17:25:06 Voltage Offset Correction: v_off_ini = 700.894 uV, v_off_fin = 702.269 uV 17:25:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.155 uVs 17:25:06 Integrated Voltage Measurement... 17:25:15 Voltage Offset Correction: v_off_ini = 707.503 uV, v_off_fin = 713.400 uV 17:25:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.213 uVs 17:25:15 Integrated Voltage Measurement... 17:25:24 Voltage Offset Correction: v_off_ini = 707.455 uV, v_off_fin = 699.068 uV 17:25:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.350 uVs 17:25:25 Integrated Voltage Measurement... 17:25:34 Voltage Offset Correction: v_off_ini = 714.144 uV, v_off_fin = 690.694 uV 17:25:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.895 uVs 17:25:34 Integrated Voltage Measurement... 17:25:43 Voltage Offset Correction: v_off_ini = 714.842 uV, v_off_fin = 712.387 uV 17:25:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.691 uVs 17:25:43 Integrated Voltage Measurement... 17:25:52 Voltage Offset Correction: v_off_ini = 705.040 uV, v_off_fin = 697.928 uV 17:25:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.698 uVs 17:25:54 I2Y Average and RMS of Measurements VT = -259.000 +- 8.120 uVs I2Y = -23.828 +- 0.747 uTm^2 17:25:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:26:02 Integrated Voltage Measurement... 17:26:11 Voltage Offset Correction: v_off_ini = 682.803 uV, v_off_fin = 687.179 uV 17:26:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.956 uVs 17:26:11 Integrated Voltage Measurement... 17:26:20 Voltage Offset Correction: v_off_ini = 688.338 uV, v_off_fin = 690.797 uV 17:26:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.056 uVs 17:26:20 Integrated Voltage Measurement... 17:26:29 Voltage Offset Correction: v_off_ini = 685.358 uV, v_off_fin = 668.699 uV 17:26:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.964 uVs 17:26:30 Integrated Voltage Measurement... 17:26:38 Voltage Offset Correction: v_off_ini = 674.006 uV, v_off_fin = 683.144 uV 17:26:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.836 uVs 17:26:39 Integrated Voltage Measurement... 17:26:47 Voltage Offset Correction: v_off_ini = 664.684 uV, v_off_fin = 679.733 uV 17:26:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.275 uVs 17:26:48 Integrated Voltage Measurement... 17:26:57 Voltage Offset Correction: v_off_ini = 705.010 uV, v_off_fin = 698.621 uV 17:26:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.099 uVs 17:27:01 I1X Average and RMS of Measurements VT = -84.364 +- 3.577 uVs I1X = 16.873 +- 0.716 uTm 17:27:03 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:27:08 Integrated Voltage Measurement... 17:27:17 Voltage Offset Correction: v_off_ini = 692.078 uV, v_off_fin = 674.160 uV 17:27:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.886 uVs 17:27:17 Integrated Voltage Measurement... 17:27:25 Voltage Offset Correction: v_off_ini = 652.935 uV, v_off_fin = 670.201 uV 17:27:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 201.603 uVs 17:27:26 Integrated Voltage Measurement... 17:27:35 Voltage Offset Correction: v_off_ini = 672.291 uV, v_off_fin = 665.075 uV 17:27:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -185.905 uVs 17:27:35 Integrated Voltage Measurement... 17:27:44 Voltage Offset Correction: v_off_ini = 675.316 uV, v_off_fin = 685.863 uV 17:27:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.085 uVs 17:27:44 Integrated Voltage Measurement... 17:27:53 Voltage Offset Correction: v_off_ini = 672.236 uV, v_off_fin = 659.404 uV 17:27:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.260 uVs 17:27:53 Integrated Voltage Measurement... 17:28:02 Voltage Offset Correction: v_off_ini = 684.567 uV, v_off_fin = 692.861 uV 17:28:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 201.796 uVs 17:28:06 I1Y Average and RMS of Measurements VT = -196.256 +- 4.300 uVs I1Y = -39.246 +- 0.861 uTm 17:28:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:28:11 Integrated Voltage Measurement... 17:28:20 Voltage Offset Correction: v_off_ini = 683.441 uV, v_off_fin = 667.975 uV 17:28:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.499 uVs 17:28:20 Integrated Voltage Measurement... 17:28:29 Voltage Offset Correction: v_off_ini = 661.668 uV, v_off_fin = 673.354 uV 17:28:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.858 uVs 17:28:29 Integrated Voltage Measurement... 17:28:38 Voltage Offset Correction: v_off_ini = 655.468 uV, v_off_fin = 652.218 uV 17:28:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.926 uVs 17:28:38 Integrated Voltage Measurement... 17:28:47 Voltage Offset Correction: v_off_ini = 680.534 uV, v_off_fin = 686.105 uV 17:28:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.890 uVs 17:28:47 Integrated Voltage Measurement... 17:28:56 Voltage Offset Correction: v_off_ini = 679.319 uV, v_off_fin = 676.376 uV 17:28:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.343 uVs 17:28:56 Integrated Voltage Measurement... 17:29:05 Voltage Offset Correction: v_off_ini = 701.493 uV, v_off_fin = 701.525 uV 17:29:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.568 uVs 17:29:08 I2X Average and RMS of Measurements VT = -92.181 +- 17.328 uVs I2X = 8.481 +- 1.594 uTm^2 17:29:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:29:13 Integrated Voltage Measurement... 17:29:22 Voltage Offset Correction: v_off_ini = 677.648 uV, v_off_fin = 681.917 uV 17:29:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.207 uVs 17:29:22 Integrated Voltage Measurement... 17:29:31 Voltage Offset Correction: v_off_ini = 664.806 uV, v_off_fin = 659.431 uV 17:29:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.368 uVs 17:29:31 Integrated Voltage Measurement... 17:29:40 Voltage Offset Correction: v_off_ini = 664.971 uV, v_off_fin = 678.320 uV 17:29:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.648 uVs 17:29:40 Integrated Voltage Measurement... 17:29:49 Voltage Offset Correction: v_off_ini = 680.292 uV, v_off_fin = 687.099 uV 17:29:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.437 uVs 17:29:49 Integrated Voltage Measurement... 17:29:58 Voltage Offset Correction: v_off_ini = 689.175 uV, v_off_fin = 673.838 uV 17:29:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.081 uVs 17:29:58 Integrated Voltage Measurement... 17:30:07 Voltage Offset Correction: v_off_ini = 698.089 uV, v_off_fin = 697.011 uV 17:30:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.893 uVs 17:30:09 I2Y Average and RMS of Measurements VT = -268.106 +- 8.216 uVs I2Y = -24.666 +- 0.756 uTm^2 17:30:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:30:30 Integrated Voltage Measurement... 17:30:39 Voltage Offset Correction: v_off_ini = 696.079 uV, v_off_fin = 698.481 uV 17:30:39 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4997 mm dXY = -0.4997 mm VT = -59.223 uVs 17:30:39 Integrated Voltage Measurement... 17:30:48 Voltage Offset Correction: v_off_ini = 694.500 uV, v_off_fin = 692.917 uV 17:30:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 98.946 uVs 17:30:48 Integrated Voltage Measurement... 17:30:57 Voltage Offset Correction: v_off_ini = 693.747 uV, v_off_fin = 698.717 uV 17:30:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.089 uVs 17:30:57 Integrated Voltage Measurement... 17:31:06 Voltage Offset Correction: v_off_ini = 697.739 uV, v_off_fin = 702.173 uV 17:31:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.065 uVs 17:31:06 Integrated Voltage Measurement... 17:31:15 Voltage Offset Correction: v_off_ini = 705.075 uV, v_off_fin = 705.115 uV 17:31:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.550 uVs 17:31:15 Integrated Voltage Measurement... 17:31:24 Voltage Offset Correction: v_off_ini = 706.878 uV, v_off_fin = 713.390 uV 17:31:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.614 uVs 17:31:28 I1X Average and RMS of Measurements VT = -86.581 +- 7.648 uVs I1X = 17.318 +- 1.528 uTm 17:31:30 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:31:35 Integrated Voltage Measurement... 17:31:44 Voltage Offset Correction: v_off_ini = 696.821 uV, v_off_fin = 696.618 uV 17:31:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.655 uVs 17:31:44 Integrated Voltage Measurement... 17:31:53 Voltage Offset Correction: v_off_ini = 711.360 uV, v_off_fin = 717.000 uV 17:31:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.588 uVs 17:31:53 Integrated Voltage Measurement... 17:32:02 Voltage Offset Correction: v_off_ini = 713.573 uV, v_off_fin = 688.278 uV 17:32:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.854 uVs 17:32:02 Integrated Voltage Measurement... 17:32:11 Voltage Offset Correction: v_off_ini = 710.028 uV, v_off_fin = 703.555 uV 17:32:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.572 uVs 17:32:11 Integrated Voltage Measurement... 17:32:20 Voltage Offset Correction: v_off_ini = 689.206 uV, v_off_fin = 686.180 uV 17:32:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.691 uVs 17:32:20 Integrated Voltage Measurement... 17:32:29 Voltage Offset Correction: v_off_ini = 700.185 uV, v_off_fin = 712.756 uV 17:32:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.474 uVs 17:32:33 I1Y Average and RMS of Measurements VT = -205.806 +- 1.297 uVs I1Y = -41.161 +- 0.259 uTm 17:32:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:32:41 Integrated Voltage Measurement... 17:32:50 Voltage Offset Correction: v_off_ini = 683.979 uV, v_off_fin = 685.863 uV 17:32:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -110.552 uVs 17:32:50 Integrated Voltage Measurement... 17:32:59 Voltage Offset Correction: v_off_ini = 707.090 uV, v_off_fin = 698.619 uV 17:32:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.384 uVs 17:32:59 Integrated Voltage Measurement... 17:33:08 Voltage Offset Correction: v_off_ini = 695.322 uV, v_off_fin = 679.383 uV 17:33:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.854 uVs 17:33:08 Integrated Voltage Measurement... 17:33:17 Voltage Offset Correction: v_off_ini = 702.424 uV, v_off_fin = 694.164 uV 17:33:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.637 uVs 17:33:17 Integrated Voltage Measurement... 17:33:26 Voltage Offset Correction: v_off_ini = 679.748 uV, v_off_fin = 685.952 uV 17:33:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.560 uVs 17:33:26 Integrated Voltage Measurement... 17:33:35 Voltage Offset Correction: v_off_ini = 699.384 uV, v_off_fin = 708.104 uV 17:33:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.930 uVs 17:33:37 I2X Average and RMS of Measurements VT = -95.986 +- 3.973 uVs I2X = 8.831 +- 0.365 uTm^2 17:33:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:33:45 Integrated Voltage Measurement... 17:33:54 Voltage Offset Correction: v_off_ini = 709.052 uV, v_off_fin = 711.898 uV 17:33:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.462 uVs 17:33:54 Integrated Voltage Measurement... 17:34:03 Voltage Offset Correction: v_off_ini = 707.431 uV, v_off_fin = 710.242 uV 17:34:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.360 uVs 17:34:03 Integrated Voltage Measurement... 17:34:12 Voltage Offset Correction: v_off_ini = 710.892 uV, v_off_fin = 689.868 uV 17:34:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.297 uVs 17:34:12 Integrated Voltage Measurement... 17:34:21 Voltage Offset Correction: v_off_ini = 698.345 uV, v_off_fin = 699.994 uV 17:34:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.809 uVs 17:34:21 Integrated Voltage Measurement... 17:34:30 Voltage Offset Correction: v_off_ini = 706.932 uV, v_off_fin = 693.931 uV 17:34:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.251 uVs 17:34:30 Integrated Voltage Measurement... 17:34:39 Voltage Offset Correction: v_off_ini = 698.301 uV, v_off_fin = 705.025 uV 17:34:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.484 uVs 17:34:42 I2Y Average and RMS of Measurements VT = -267.777 +- 3.050 uVs I2Y = -24.636 +- 0.281 uTm^2 17:34:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:34:50 Integrated Voltage Measurement... 17:34:59 Voltage Offset Correction: v_off_ini = 699.222 uV, v_off_fin = 672.428 uV 17:34:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -73.680 uVs 17:34:59 Integrated Voltage Measurement... 17:35:08 Voltage Offset Correction: v_off_ini = 705.526 uV, v_off_fin = 693.386 uV 17:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.933 uVs 17:35:08 Integrated Voltage Measurement... 17:35:17 Voltage Offset Correction: v_off_ini = 672.029 uV, v_off_fin = 676.098 uV 17:35:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.311 uVs 17:35:17 Integrated Voltage Measurement... 17:35:26 Voltage Offset Correction: v_off_ini = 683.852 uV, v_off_fin = 689.087 uV 17:35:26 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.579 uVs 17:35:26 Integrated Voltage Measurement... 17:35:35 Voltage Offset Correction: v_off_ini = 689.710 uV, v_off_fin = 687.326 uV 17:35:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.752 uVs 17:35:35 Integrated Voltage Measurement... 17:35:44 Voltage Offset Correction: v_off_ini = 675.447 uV, v_off_fin = 690.617 uV 17:35:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.600 uVs 17:35:49 I1X Average and RMS of Measurements VT = -75.809 +- 12.046 uVs I1X = 15.163 +- 2.409 uTm 17:35:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:35:55 Integrated Voltage Measurement... 17:36:04 Voltage Offset Correction: v_off_ini = 671.785 uV, v_off_fin = 670.363 uV 17:36:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.886 uVs 17:36:04 Integrated Voltage Measurement... 17:36:13 Voltage Offset Correction: v_off_ini = 668.085 uV, v_off_fin = 684.960 uV 17:36:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.053 uVs 17:36:13 Integrated Voltage Measurement... 17:36:22 Voltage Offset Correction: v_off_ini = 671.650 uV, v_off_fin = 657.314 uV 17:36:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.283 uVs 17:36:22 Integrated Voltage Measurement... 17:36:31 Voltage Offset Correction: v_off_ini = 662.288 uV, v_off_fin = 666.327 uV 17:36:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.698 uVs 17:36:31 Integrated Voltage Measurement... 17:36:40 Voltage Offset Correction: v_off_ini = 657.692 uV, v_off_fin = 664.266 uV 17:36:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.801 uVs 17:36:40 Integrated Voltage Measurement... 17:36:49 Voltage Offset Correction: v_off_ini = 658.136 uV, v_off_fin = 675.448 uV 17:36:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.073 uVs 17:36:54 I1Y Average and RMS of Measurements VT = -201.299 +- 5.540 uVs I1Y = -40.260 +- 1.109 uTm 17:36:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:37:01 Integrated Voltage Measurement... 17:37:10 Voltage Offset Correction: v_off_ini = 652.660 uV, v_off_fin = 655.483 uV 17:37:10 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.378 uVs 17:37:10 Integrated Voltage Measurement... 17:37:19 Voltage Offset Correction: v_off_ini = 659.015 uV, v_off_fin = 672.230 uV 17:37:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.256 uVs 17:37:19 Integrated Voltage Measurement... 17:37:28 Voltage Offset Correction: v_off_ini = 663.589 uV, v_off_fin = 641.075 uV 17:37:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.661 uVs 17:37:28 Integrated Voltage Measurement... 17:37:37 Voltage Offset Correction: v_off_ini = 641.095 uV, v_off_fin = 657.774 uV 17:37:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.275 uVs 17:37:37 Integrated Voltage Measurement... 17:37:46 Voltage Offset Correction: v_off_ini = 619.865 uV, v_off_fin = 628.988 uV 17:37:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.862 uVs 17:37:46 Integrated Voltage Measurement... 17:37:55 Voltage Offset Correction: v_off_ini = 646.956 uV, v_off_fin = 665.040 uV 17:37:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.808 uVs 17:37:58 I2X Average and RMS of Measurements VT = -88.373 +- 2.096 uVs I2X = 8.130 +- 0.193 uTm^2 17:38:03 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:38:05 Integrated Voltage Measurement... 17:38:14 Voltage Offset Correction: v_off_ini = 640.754 uV, v_off_fin = 619.785 uV 17:38:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.051 uVs 17:38:15 Integrated Voltage Measurement... 17:38:23 Voltage Offset Correction: v_off_ini = 632.532 uV, v_off_fin = 660.220 uV 17:38:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.907 uVs 17:38:24 Integrated Voltage Measurement... 17:38:33 Voltage Offset Correction: v_off_ini = 656.553 uV, v_off_fin = 660.333 uV 17:38:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.946 uVs 17:38:33 Integrated Voltage Measurement... 17:38:42 Voltage Offset Correction: v_off_ini = 664.174 uV, v_off_fin = 660.510 uV 17:38:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.834 uVs 17:38:42 Integrated Voltage Measurement... 17:38:51 Voltage Offset Correction: v_off_ini = 645.401 uV, v_off_fin = 649.566 uV 17:38:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.999 uVs 17:38:51 Integrated Voltage Measurement... 17:39:00 Voltage Offset Correction: v_off_ini = 662.464 uV, v_off_fin = 671.395 uV 17:39:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.842 uVs 17:39:02 I2Y Average and RMS of Measurements VT = -260.263 +- 5.298 uVs I2Y = -23.944 +- 0.487 uTm^2 17:39:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:39:11 Integrated Voltage Measurement... 17:39:20 Voltage Offset Correction: v_off_ini = 635.297 uV, v_off_fin = 644.532 uV 17:39:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.092 uVs 17:39:20 Integrated Voltage Measurement... 17:39:29 Voltage Offset Correction: v_off_ini = 645.568 uV, v_off_fin = 641.716 uV 17:39:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.387 uVs 17:39:29 Integrated Voltage Measurement... 17:39:38 Voltage Offset Correction: v_off_ini = 645.421 uV, v_off_fin = 640.968 uV 17:39:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.019 uVs 17:39:38 Integrated Voltage Measurement... 17:39:47 Voltage Offset Correction: v_off_ini = 643.383 uV, v_off_fin = 652.291 uV 17:39:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.462 uVs 17:39:47 Integrated Voltage Measurement... 17:39:56 Voltage Offset Correction: v_off_ini = 641.289 uV, v_off_fin = 637.130 uV 17:39:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.717 uVs 17:39:56 Integrated Voltage Measurement... 17:40:05 Voltage Offset Correction: v_off_ini = 645.149 uV, v_off_fin = 655.570 uV 17:40:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.133 uVs 17:40:09 I1X Average and RMS of Measurements VT = -71.635 +- 3.095 uVs I1X = 14.327 +- 0.619 uTm 17:40:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:40:16 Integrated Voltage Measurement... 17:40:25 Voltage Offset Correction: v_off_ini = 663.274 uV, v_off_fin = 649.642 uV 17:40:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -199.285 uVs 17:40:25 Integrated Voltage Measurement... 17:40:34 Voltage Offset Correction: v_off_ini = 667.388 uV, v_off_fin = 668.308 uV 17:40:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.769 uVs 17:40:34 Integrated Voltage Measurement... 17:40:43 Voltage Offset Correction: v_off_ini = 643.063 uV, v_off_fin = 630.382 uV 17:40:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.867 uVs 17:40:43 Integrated Voltage Measurement... 17:40:52 Voltage Offset Correction: v_off_ini = 651.007 uV, v_off_fin = 665.563 uV 17:40:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.998 uVs 17:40:52 Integrated Voltage Measurement... 17:41:01 Voltage Offset Correction: v_off_ini = 665.023 uV, v_off_fin = 644.946 uV 17:41:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.308 uVs 17:41:01 Integrated Voltage Measurement... 17:41:10 Voltage Offset Correction: v_off_ini = 640.836 uV, v_off_fin = 640.343 uV 17:41:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.501 uVs 17:41:14 I1Y Average and RMS of Measurements VT = -201.621 +- 1.247 uVs I1Y = -40.325 +- 0.250 uTm 17:41:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:41:22 Integrated Voltage Measurement... 17:41:31 Voltage Offset Correction: v_off_ini = 635.982 uV, v_off_fin = 637.774 uV 17:41:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -83.824 uVs 17:41:31 Integrated Voltage Measurement... 17:41:40 Voltage Offset Correction: v_off_ini = 643.037 uV, v_off_fin = 656.728 uV 17:41:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.913 uVs 17:41:40 Integrated Voltage Measurement... 17:41:49 Voltage Offset Correction: v_off_ini = 634.342 uV, v_off_fin = 621.494 uV 17:41:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.254 uVs 17:41:49 Integrated Voltage Measurement... 17:41:58 Voltage Offset Correction: v_off_ini = 633.184 uV, v_off_fin = 642.744 uV 17:41:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.239 uVs 17:41:58 Integrated Voltage Measurement... 17:42:07 Voltage Offset Correction: v_off_ini = 632.555 uV, v_off_fin = 647.690 uV 17:42:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.673 uVs 17:42:07 Integrated Voltage Measurement... 17:42:16 Voltage Offset Correction: v_off_ini = 655.310 uV, v_off_fin = 641.778 uV 17:42:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.429 uVs 17:42:18 I2X Average and RMS of Measurements VT = -98.722 +- 7.939 uVs I2X = 9.082 +- 0.731 uTm^2 17:42:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:42:26 Integrated Voltage Measurement... 17:42:35 Voltage Offset Correction: v_off_ini = 625.092 uV, v_off_fin = 629.827 uV 17:42:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.554 uVs 17:42:35 Integrated Voltage Measurement... 17:42:44 Voltage Offset Correction: v_off_ini = 618.158 uV, v_off_fin = 631.607 uV 17:42:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.955 uVs 17:42:44 Integrated Voltage Measurement... 17:42:53 Voltage Offset Correction: v_off_ini = 659.658 uV, v_off_fin = 648.081 uV 17:42:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.655 uVs 17:42:53 Integrated Voltage Measurement... 17:43:02 Voltage Offset Correction: v_off_ini = 649.031 uV, v_off_fin = 648.403 uV 17:43:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.469 uVs 17:43:02 Integrated Voltage Measurement... 17:43:11 Voltage Offset Correction: v_off_ini = 639.184 uV, v_off_fin = 652.842 uV 17:43:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.054 uVs 17:43:11 Integrated Voltage Measurement... 17:43:20 Voltage Offset Correction: v_off_ini = 642.678 uV, v_off_fin = 654.206 uV 17:43:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.180 uVs 17:43:23 I2Y Average and RMS of Measurements VT = -253.144 +- 4.275 uVs I2Y = -23.289 +- 0.393 uTm^2 17:43:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:43:32 Integrated Voltage Measurement... 17:43:41 Voltage Offset Correction: v_off_ini = 645.336 uV, v_off_fin = 630.078 uV 17:43:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.844 uVs 17:43:41 Integrated Voltage Measurement... 17:43:50 Voltage Offset Correction: v_off_ini = 638.373 uV, v_off_fin = 651.401 uV 17:43:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.923 uVs 17:43:50 Integrated Voltage Measurement... 17:43:59 Voltage Offset Correction: v_off_ini = 648.393 uV, v_off_fin = 648.070 uV 17:43:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.699 uVs 17:43:59 Integrated Voltage Measurement... 17:44:08 Voltage Offset Correction: v_off_ini = 631.807 uV, v_off_fin = 647.973 uV 17:44:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.920 uVs 17:44:08 Integrated Voltage Measurement... 17:44:17 Voltage Offset Correction: v_off_ini = 638.735 uV, v_off_fin = 634.869 uV 17:44:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.960 uVs 17:44:17 Integrated Voltage Measurement... 17:44:26 Voltage Offset Correction: v_off_ini = 639.052 uV, v_off_fin = 647.447 uV 17:44:26 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.663 uVs 17:44:30 I1X Average and RMS of Measurements VT = -84.668 +- 8.659 uVs I1X = 16.934 +- 1.732 uTm 17:44:32 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:44:37 Integrated Voltage Measurement... 17:44:46 Voltage Offset Correction: v_off_ini = 658.778 uV, v_off_fin = 637.742 uV 17:44:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.423 uVs 17:44:46 Integrated Voltage Measurement... 17:44:54 Voltage Offset Correction: v_off_ini = 641.759 uV, v_off_fin = 656.427 uV 17:44:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.661 uVs 17:44:55 Integrated Voltage Measurement... 17:45:03 Voltage Offset Correction: v_off_ini = 629.879 uV, v_off_fin = 626.089 uV 17:45:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.007 uVs 17:45:03 Integrated Voltage Measurement... 17:45:12 Voltage Offset Correction: v_off_ini = 642.384 uV, v_off_fin = 639.859 uV 17:45:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.757 uVs 17:45:13 Integrated Voltage Measurement... 17:45:21 Voltage Offset Correction: v_off_ini = 649.944 uV, v_off_fin = 647.107 uV 17:45:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.402 uVs 17:45:22 Integrated Voltage Measurement... 17:45:30 Voltage Offset Correction: v_off_ini = 642.173 uV, v_off_fin = 653.983 uV 17:45:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.997 uVs 17:45:35 I1Y Average and RMS of Measurements VT = -199.541 +- 6.965 uVs I1Y = -39.908 +- 1.393 uTm 17:45:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:45:42 Integrated Voltage Measurement... 17:45:51 Voltage Offset Correction: v_off_ini = 623.424 uV, v_off_fin = 621.316 uV 17:45:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.768 uVs 17:45:51 Integrated Voltage Measurement... 17:46:00 Voltage Offset Correction: v_off_ini = 638.072 uV, v_off_fin = 647.049 uV 17:46:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.830 uVs 17:46:01 Integrated Voltage Measurement... 17:46:10 Voltage Offset Correction: v_off_ini = 648.451 uV, v_off_fin = 631.027 uV 17:46:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.191 uVs 17:46:10 Integrated Voltage Measurement... 17:46:19 Voltage Offset Correction: v_off_ini = 623.253 uV, v_off_fin = 643.518 uV 17:46:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.276 uVs 17:46:19 Integrated Voltage Measurement... 17:46:28 Voltage Offset Correction: v_off_ini = 643.715 uV, v_off_fin = 641.449 uV 17:46:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.923 uVs 17:46:28 Integrated Voltage Measurement... 17:46:37 Voltage Offset Correction: v_off_ini = 633.351 uV, v_off_fin = 641.312 uV 17:46:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.963 uVs 17:46:39 I2X Average and RMS of Measurements VT = -97.992 +- 4.799 uVs I2X = 9.015 +- 0.442 uTm^2 17:46:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:46:47 Integrated Voltage Measurement... 17:46:56 Voltage Offset Correction: v_off_ini = 624.879 uV, v_off_fin = 625.969 uV 17:46:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.859 uVs 17:46:56 Integrated Voltage Measurement... 17:47:05 Voltage Offset Correction: v_off_ini = 634.347 uV, v_off_fin = 625.575 uV 17:47:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.402 uVs 17:47:05 Integrated Voltage Measurement... 17:47:14 Voltage Offset Correction: v_off_ini = 615.338 uV, v_off_fin = 630.529 uV 17:47:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.390 uVs 17:47:14 Integrated Voltage Measurement... 17:47:23 Voltage Offset Correction: v_off_ini = 617.913 uV, v_off_fin = 625.070 uV 17:47:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.914 uVs 17:47:23 Integrated Voltage Measurement... 17:47:32 Voltage Offset Correction: v_off_ini = 635.366 uV, v_off_fin = 643.777 uV 17:47:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.935 uVs 17:47:32 Integrated Voltage Measurement... 17:47:41 Voltage Offset Correction: v_off_ini = 651.981 uV, v_off_fin = 646.883 uV 17:47:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 245.850 uVs 17:47:43 I2Y Average and RMS of Measurements VT = -251.225 +- 2.427 uVs I2Y = -23.113 +- 0.223 uTm^2 17:47:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:47:52 Integrated Voltage Measurement... 17:48:01 Voltage Offset Correction: v_off_ini = 651.308 uV, v_off_fin = 642.224 uV 17:48:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.932 uVs 17:48:01 Integrated Voltage Measurement... 17:48:10 Voltage Offset Correction: v_off_ini = 627.907 uV, v_off_fin = 628.371 uV 17:48:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.144 uVs 17:48:10 Integrated Voltage Measurement... 17:48:19 Voltage Offset Correction: v_off_ini = 643.804 uV, v_off_fin = 655.239 uV 17:48:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.257 uVs 17:48:20 Integrated Voltage Measurement... 17:48:28 Voltage Offset Correction: v_off_ini = 654.400 uV, v_off_fin = 664.583 uV 17:48:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.096 uVs 17:48:29 Integrated Voltage Measurement... 17:48:38 Voltage Offset Correction: v_off_ini = 652.331 uV, v_off_fin = 669.346 uV 17:48:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.227 uVs 17:48:38 Integrated Voltage Measurement... 17:48:47 Voltage Offset Correction: v_off_ini = 670.668 uV, v_off_fin = 641.461 uV 17:48:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.900 uVs 17:48:51 I1X Average and RMS of Measurements VT = -83.759 +- 9.691 uVs I1X = 16.752 +- 1.938 uTm 17:48:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:48:58 Integrated Voltage Measurement... 17:49:07 Voltage Offset Correction: v_off_ini = 658.864 uV, v_off_fin = 645.883 uV 17:49:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.431 uVs 17:49:07 Integrated Voltage Measurement... 17:49:16 Voltage Offset Correction: v_off_ini = 649.076 uV, v_off_fin = 660.171 uV 17:49:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.644 uVs 17:49:16 Integrated Voltage Measurement... 17:49:25 Voltage Offset Correction: v_off_ini = 659.887 uV, v_off_fin = 638.464 uV 17:49:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.233 uVs 17:49:25 Integrated Voltage Measurement... 17:49:34 Voltage Offset Correction: v_off_ini = 646.188 uV, v_off_fin = 640.279 uV 17:49:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.125 uVs 17:49:34 Integrated Voltage Measurement... 17:49:43 Voltage Offset Correction: v_off_ini = 655.353 uV, v_off_fin = 648.994 uV 17:49:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.355 uVs 17:49:43 Integrated Voltage Measurement... 17:49:52 Voltage Offset Correction: v_off_ini = 654.968 uV, v_off_fin = 661.429 uV 17:49:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.093 uVs 17:49:56 I1Y Average and RMS of Measurements VT = -197.147 +- 12.808 uVs I1Y = -39.429 +- 2.562 uTm 17:50:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:50:04 Integrated Voltage Measurement... 17:50:13 Voltage Offset Correction: v_off_ini = 657.172 uV, v_off_fin = 647.351 uV 17:50:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -99.509 uVs 17:50:13 Integrated Voltage Measurement... 17:50:22 Voltage Offset Correction: v_off_ini = 646.835 uV, v_off_fin = 664.833 uV 17:50:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.864 uVs 17:50:22 Integrated Voltage Measurement... 17:50:31 Voltage Offset Correction: v_off_ini = 659.402 uV, v_off_fin = 633.914 uV 17:50:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.269 uVs 17:50:31 Integrated Voltage Measurement... 17:50:40 Voltage Offset Correction: v_off_ini = 650.337 uV, v_off_fin = 644.082 uV 17:50:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.374 uVs 17:50:40 Integrated Voltage Measurement... 17:50:49 Voltage Offset Correction: v_off_ini = 640.699 uV, v_off_fin = 633.578 uV 17:50:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.917 uVs 17:50:49 Integrated Voltage Measurement... 17:50:58 Voltage Offset Correction: v_off_ini = 653.019 uV, v_off_fin = 639.127 uV 17:50:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.776 uVs 17:51:00 I2X Average and RMS of Measurements VT = -86.451 +- 4.631 uVs I2X = 7.953 +- 0.426 uTm^2 17:51:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:51:08 Integrated Voltage Measurement... 17:51:17 Voltage Offset Correction: v_off_ini = 645.913 uV, v_off_fin = 647.112 uV 17:51:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.638 uVs 17:51:17 Integrated Voltage Measurement... 17:51:26 Voltage Offset Correction: v_off_ini = 651.407 uV, v_off_fin = 621.696 uV 17:51:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.727 uVs 17:51:26 Integrated Voltage Measurement... 17:51:35 Voltage Offset Correction: v_off_ini = 652.040 uV, v_off_fin = 630.937 uV 17:51:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.121 uVs 17:51:35 Integrated Voltage Measurement... 17:51:44 Voltage Offset Correction: v_off_ini = 644.409 uV, v_off_fin = 635.876 uV 17:51:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 232.421 uVs 17:51:44 Integrated Voltage Measurement... 17:51:53 Voltage Offset Correction: v_off_ini = 633.509 uV, v_off_fin = 624.584 uV 17:51:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.681 uVs 17:51:53 Integrated Voltage Measurement... 17:52:02 Voltage Offset Correction: v_off_ini = 628.769 uV, v_off_fin = 645.098 uV 17:52:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.772 uVs 17:52:05 I2Y Average and RMS of Measurements VT = -241.393 +- 6.158 uVs I2Y = -22.209 +- 0.566 uTm^2 17:52:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:52:17 Integrated Voltage Measurement... 17:52:26 Voltage Offset Correction: v_off_ini = 631.885 uV, v_off_fin = 610.378 uV 17:52:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.198 uVs 17:52:26 Integrated Voltage Measurement... 17:52:35 Voltage Offset Correction: v_off_ini = 608.356 uV, v_off_fin = 626.327 uV 17:52:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.734 uVs 17:52:35 Integrated Voltage Measurement... 17:52:44 Voltage Offset Correction: v_off_ini = 625.458 uV, v_off_fin = 632.879 uV 17:52:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.385 uVs 17:52:44 Integrated Voltage Measurement... 17:52:53 Voltage Offset Correction: v_off_ini = 613.862 uV, v_off_fin = 617.456 uV 17:52:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.201 uVs 17:52:53 Integrated Voltage Measurement... 17:53:02 Voltage Offset Correction: v_off_ini = 614.635 uV, v_off_fin = 630.326 uV 17:53:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.961 uVs 17:53:02 Integrated Voltage Measurement... 17:53:11 Voltage Offset Correction: v_off_ini = 631.131 uV, v_off_fin = 617.869 uV 17:53:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.774 uVs 17:53:15 I1X Average and RMS of Measurements VT = -80.209 +- 14.350 uVs I1X = 16.042 +- 2.870 uTm 17:53:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:53:22 Integrated Voltage Measurement... 17:53:31 Voltage Offset Correction: v_off_ini = 618.168 uV, v_off_fin = 613.256 uV 17:53:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.445 uVs 17:53:31 Integrated Voltage Measurement... 17:53:40 Voltage Offset Correction: v_off_ini = 615.328 uV, v_off_fin = 625.049 uV 17:53:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.274 uVs 17:53:40 Integrated Voltage Measurement... 17:53:49 Voltage Offset Correction: v_off_ini = 635.812 uV, v_off_fin = 629.923 uV 17:53:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.552 uVs 17:53:49 Integrated Voltage Measurement... 17:53:58 Voltage Offset Correction: v_off_ini = 618.278 uV, v_off_fin = 629.369 uV 17:53:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.670 uVs 17:53:58 Integrated Voltage Measurement... 17:54:07 Voltage Offset Correction: v_off_ini = 622.426 uV, v_off_fin = 599.370 uV 17:54:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.136 uVs 17:54:07 Integrated Voltage Measurement... 17:54:16 Voltage Offset Correction: v_off_ini = 621.273 uV, v_off_fin = 610.161 uV 17:54:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.256 uVs 17:54:20 I1Y Average and RMS of Measurements VT = -192.055 +- 5.006 uVs I1Y = -38.411 +- 1.001 uTm 17:54:23 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:54:25 Integrated Voltage Measurement... 17:54:34 Voltage Offset Correction: v_off_ini = 588.011 uV, v_off_fin = 596.686 uV 17:54:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.547 uVs 17:54:34 Integrated Voltage Measurement... 17:54:43 Voltage Offset Correction: v_off_ini = 616.330 uV, v_off_fin = 602.958 uV 17:54:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.353 uVs 17:54:43 Integrated Voltage Measurement... 17:54:52 Voltage Offset Correction: v_off_ini = 596.402 uV, v_off_fin = 589.469 uV 17:54:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.775 uVs 17:54:52 Integrated Voltage Measurement... 17:55:01 Voltage Offset Correction: v_off_ini = 595.987 uV, v_off_fin = 586.549 uV 17:55:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.088 uVs 17:55:01 Integrated Voltage Measurement... 17:55:10 Voltage Offset Correction: v_off_ini = 593.939 uV, v_off_fin = 570.351 uV 17:55:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.622 uVs 17:55:10 Integrated Voltage Measurement... 17:55:19 Voltage Offset Correction: v_off_ini = 597.087 uV, v_off_fin = 594.330 uV 17:55:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.179 uVs 17:55:22 I2X Average and RMS of Measurements VT = -83.094 +- 3.657 uVs I2X = 7.645 +- 0.337 uTm^2 17:55:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:55:27 Integrated Voltage Measurement... 17:55:36 Voltage Offset Correction: v_off_ini = 573.849 uV, v_off_fin = 590.577 uV 17:55:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.424 uVs 17:55:36 Integrated Voltage Measurement... 17:55:45 Voltage Offset Correction: v_off_ini = 573.126 uV, v_off_fin = 577.940 uV 17:55:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.656 uVs 17:55:45 Integrated Voltage Measurement... 17:55:54 Voltage Offset Correction: v_off_ini = 565.559 uV, v_off_fin = 559.895 uV 17:55:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.306 uVs 17:55:54 Integrated Voltage Measurement... 17:56:03 Voltage Offset Correction: v_off_ini = 539.490 uV, v_off_fin = 554.174 uV 17:56:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.220 uVs 17:56:03 Integrated Voltage Measurement... 17:56:12 Voltage Offset Correction: v_off_ini = 558.432 uV, v_off_fin = 546.064 uV 17:56:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.360 uVs 17:56:12 Integrated Voltage Measurement... 17:56:21 Voltage Offset Correction: v_off_ini = 548.066 uV, v_off_fin = 551.198 uV 17:56:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.302 uVs 17:56:24 I2Y Average and RMS of Measurements VT = -262.045 +- 2.363 uVs I2Y = -24.108 +- 0.217 uTm^2 17:56:28 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:56:32 Integrated Voltage Measurement... 17:56:41 Voltage Offset Correction: v_off_ini = 550.811 uV, v_off_fin = 558.725 uV 17:56:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -79.131 uVs 17:56:41 Integrated Voltage Measurement... 17:56:50 Voltage Offset Correction: v_off_ini = 556.589 uV, v_off_fin = 558.550 uV 17:56:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.716 uVs 17:56:50 Integrated Voltage Measurement... 17:56:59 Voltage Offset Correction: v_off_ini = 553.238 uV, v_off_fin = 552.938 uV 17:56:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.602 uVs 17:56:59 Integrated Voltage Measurement... 17:57:08 Voltage Offset Correction: v_off_ini = 554.945 uV, v_off_fin = 555.825 uV 17:57:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.152 uVs 17:57:08 Integrated Voltage Measurement... 17:57:17 Voltage Offset Correction: v_off_ini = 559.415 uV, v_off_fin = 572.411 uV 17:57:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.621 uVs 17:57:17 Integrated Voltage Measurement... 17:57:26 Voltage Offset Correction: v_off_ini = 549.375 uV, v_off_fin = 556.310 uV 17:57:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.313 uVs 17:57:30 I1X Average and RMS of Measurements VT = -87.756 +- 2.084 uVs I1X = 17.551 +- 0.416 uTm 17:57:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:57:37 Integrated Voltage Measurement... 17:57:46 Voltage Offset Correction: v_off_ini = 544.860 uV, v_off_fin = 548.980 uV 17:57:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.089 uVs 17:57:46 Integrated Voltage Measurement... 17:57:55 Voltage Offset Correction: v_off_ini = 553.086 uV, v_off_fin = 557.503 uV 17:57:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.918 uVs 17:57:55 Integrated Voltage Measurement... 17:58:04 Voltage Offset Correction: v_off_ini = 562.347 uV, v_off_fin = 560.444 uV 17:58:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.536 uVs 17:58:04 Integrated Voltage Measurement... 17:58:13 Voltage Offset Correction: v_off_ini = 565.405 uV, v_off_fin = 564.348 uV 17:58:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.448 uVs 17:58:13 Integrated Voltage Measurement... 17:58:22 Voltage Offset Correction: v_off_ini = 558.833 uV, v_off_fin = 554.778 uV 17:58:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.380 uVs 17:58:22 Integrated Voltage Measurement... 17:58:31 Voltage Offset Correction: v_off_ini = 547.720 uV, v_off_fin = 561.814 uV 17:58:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.312 uVs 17:58:35 I1Y Average and RMS of Measurements VT = -196.947 +- 5.360 uVs I1Y = -39.389 +- 1.072 uTm 17:58:38 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:58:40 Integrated Voltage Measurement... 17:58:49 Voltage Offset Correction: v_off_ini = 535.154 uV, v_off_fin = 535.403 uV 17:58:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.125 uVs 17:58:49 Integrated Voltage Measurement... 17:58:58 Voltage Offset Correction: v_off_ini = 563.491 uV, v_off_fin = 556.970 uV 17:58:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.596 uVs 17:58:58 Integrated Voltage Measurement... 17:59:07 Voltage Offset Correction: v_off_ini = 564.794 uV, v_off_fin = 552.971 uV 17:59:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.843 uVs 17:59:07 Integrated Voltage Measurement... 17:59:16 Voltage Offset Correction: v_off_ini = 553.231 uV, v_off_fin = 546.484 uV 17:59:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.835 uVs 17:59:16 Integrated Voltage Measurement... 17:59:25 Voltage Offset Correction: v_off_ini = 563.374 uV, v_off_fin = 558.364 uV 17:59:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.705 uVs 17:59:25 Integrated Voltage Measurement... 17:59:34 Voltage Offset Correction: v_off_ini = 558.562 uV, v_off_fin = 567.332 uV 17:59:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.891 uVs 17:59:37 I2X Average and RMS of Measurements VT = -96.833 +- 4.551 uVs I2X = 8.909 +- 0.419 uTm^2 17:59:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:59:42 Integrated Voltage Measurement... 17:59:51 Voltage Offset Correction: v_off_ini = 557.705 uV, v_off_fin = 559.434 uV 17:59:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.022 uVs 17:59:51 Integrated Voltage Measurement... 18:00:00 Voltage Offset Correction: v_off_ini = 553.419 uV, v_off_fin = 571.190 uV 18:00:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.081 uVs 18:00:00 Integrated Voltage Measurement... 18:00:09 Voltage Offset Correction: v_off_ini = 569.462 uV, v_off_fin = 567.076 uV 18:00:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.013 uVs 18:00:09 Integrated Voltage Measurement... 18:00:18 Voltage Offset Correction: v_off_ini = 565.616 uV, v_off_fin = 568.354 uV 18:00:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.470 uVs 18:00:18 Integrated Voltage Measurement... 18:00:27 Voltage Offset Correction: v_off_ini = 561.714 uV, v_off_fin = 565.519 uV 18:00:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.240 uVs 18:00:27 Integrated Voltage Measurement... 18:00:36 Voltage Offset Correction: v_off_ini = 559.800 uV, v_off_fin = 567.751 uV 18:00:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.827 uVs 18:00:39 I2Y Average and RMS of Measurements VT = -248.776 +- 9.940 uVs I2Y = -22.887 +- 0.914 uTm^2 18:00:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:00:47 Integrated Voltage Measurement... 18:00:56 Voltage Offset Correction: v_off_ini = 572.013 uV, v_off_fin = 564.811 uV 18:00:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.055 uVs 18:00:56 Integrated Voltage Measurement... 18:01:05 Voltage Offset Correction: v_off_ini = 567.249 uV, v_off_fin = 547.426 uV 18:01:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.544 uVs 18:01:05 Integrated Voltage Measurement... 18:01:14 Voltage Offset Correction: v_off_ini = 539.745 uV, v_off_fin = 559.113 uV 18:01:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.551 uVs 18:01:14 Integrated Voltage Measurement... 18:01:23 Voltage Offset Correction: v_off_ini = 565.014 uV, v_off_fin = 562.584 uV 18:01:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.405 uVs 18:01:23 Integrated Voltage Measurement... 18:01:32 Voltage Offset Correction: v_off_ini = 557.190 uV, v_off_fin = 553.853 uV 18:01:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.780 uVs 18:01:32 Integrated Voltage Measurement... 18:01:41 Voltage Offset Correction: v_off_ini = 543.490 uV, v_off_fin = 547.382 uV 18:01:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.235 uVs 18:01:45 I1X Average and RMS of Measurements VT = -77.095 +- 8.493 uVs I1X = 15.419 +- 1.699 uTm 18:01:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:01:52 Integrated Voltage Measurement... 18:02:01 Voltage Offset Correction: v_off_ini = 575.734 uV, v_off_fin = 567.712 uV 18:02:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.890 uVs 18:02:01 Integrated Voltage Measurement... 18:02:10 Voltage Offset Correction: v_off_ini = 589.545 uV, v_off_fin = 592.583 uV 18:02:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.381 uVs 18:02:10 Integrated Voltage Measurement... 18:02:19 Voltage Offset Correction: v_off_ini = 588.991 uV, v_off_fin = 585.038 uV 18:02:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.119 uVs 18:02:19 Integrated Voltage Measurement... 18:02:28 Voltage Offset Correction: v_off_ini = 595.440 uV, v_off_fin = 603.115 uV 18:02:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.821 uVs 18:02:28 Integrated Voltage Measurement... 18:02:37 Voltage Offset Correction: v_off_ini = 593.674 uV, v_off_fin = 583.423 uV 18:02:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.937 uVs 18:02:37 Integrated Voltage Measurement... 18:02:46 Voltage Offset Correction: v_off_ini = 610.349 uV, v_off_fin = 608.637 uV 18:02:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.220 uVs 18:02:50 I1Y Average and RMS of Measurements VT = -192.895 +- 2.005 uVs I1Y = -38.579 +- 0.401 uTm 18:02:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:02:55 Integrated Voltage Measurement... 18:03:04 Voltage Offset Correction: v_off_ini = 564.036 uV, v_off_fin = 569.620 uV 18:03:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.089 uVs 18:03:04 Integrated Voltage Measurement... 18:03:13 Voltage Offset Correction: v_off_ini = 593.167 uV, v_off_fin = 581.944 uV 18:03:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.715 uVs 18:03:13 Integrated Voltage Measurement... 18:03:22 Voltage Offset Correction: v_off_ini = 588.933 uV, v_off_fin = 589.456 uV 18:03:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.199 uVs 18:03:23 Integrated Voltage Measurement... 18:03:32 Voltage Offset Correction: v_off_ini = 594.019 uV, v_off_fin = 603.389 uV 18:03:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.234 uVs 18:03:32 Integrated Voltage Measurement... 18:03:41 Voltage Offset Correction: v_off_ini = 580.132 uV, v_off_fin = 563.644 uV 18:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.139 uVs 18:03:41 Integrated Voltage Measurement... 18:03:50 Voltage Offset Correction: v_off_ini = 584.571 uV, v_off_fin = 593.757 uV 18:03:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.041 uVs 18:03:52 I2X Average and RMS of Measurements VT = -88.236 +- 4.486 uVs I2X = 8.118 +- 0.413 uTm^2 18:03:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:03:57 Integrated Voltage Measurement... 18:04:06 Voltage Offset Correction: v_off_ini = 561.810 uV, v_off_fin = 578.656 uV 18:04:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.848 uVs 18:04:06 Integrated Voltage Measurement... 18:04:15 Voltage Offset Correction: v_off_ini = 574.336 uV, v_off_fin = 573.615 uV 18:04:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.979 uVs 18:04:15 Integrated Voltage Measurement... 18:04:24 Voltage Offset Correction: v_off_ini = 584.520 uV, v_off_fin = 595.487 uV 18:04:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.035 uVs 18:04:24 Integrated Voltage Measurement... 18:04:33 Voltage Offset Correction: v_off_ini = 594.002 uV, v_off_fin = 595.595 uV 18:04:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.364 uVs 18:04:33 Integrated Voltage Measurement... 18:04:42 Voltage Offset Correction: v_off_ini = 583.072 uV, v_off_fin = 583.432 uV 18:04:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.999 uVs 18:04:42 Integrated Voltage Measurement... 18:04:51 Voltage Offset Correction: v_off_ini = 586.424 uV, v_off_fin = 591.389 uV 18:04:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.453 uVs 18:04:54 I2Y Average and RMS of Measurements VT = -257.113 +- 5.523 uVs I2Y = -23.654 +- 0.508 uTm^2 18:04:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:05:02 Integrated Voltage Measurement... 18:05:11 Voltage Offset Correction: v_off_ini = 575.196 uV, v_off_fin = 570.980 uV 18:05:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -51.315 uVs 18:05:11 Integrated Voltage Measurement... 18:05:20 Voltage Offset Correction: v_off_ini = 568.245 uV, v_off_fin = 552.418 uV 18:05:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.592 uVs 18:05:20 Integrated Voltage Measurement... 18:05:29 Voltage Offset Correction: v_off_ini = 567.905 uV, v_off_fin = 573.160 uV 18:05:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.351 uVs 18:05:29 Integrated Voltage Measurement... 18:05:38 Voltage Offset Correction: v_off_ini = 575.290 uV, v_off_fin = 588.730 uV 18:05:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.138 uVs 18:05:38 Integrated Voltage Measurement... 18:05:47 Voltage Offset Correction: v_off_ini = 576.538 uV, v_off_fin = 588.585 uV 18:05:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.566 uVs 18:05:47 Integrated Voltage Measurement... 18:05:56 Voltage Offset Correction: v_off_ini = 584.912 uV, v_off_fin = 581.763 uV 18:05:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.482 uVs 18:06:00 I1X Average and RMS of Measurements VT = -72.741 +- 2.680 uVs I1X = 14.548 +- 0.536 uTm 18:06:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:06:07 Integrated Voltage Measurement... 18:06:16 Voltage Offset Correction: v_off_ini = 591.835 uV, v_off_fin = 567.843 uV 18:06:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -214.361 uVs 18:06:16 Integrated Voltage Measurement... 18:06:25 Voltage Offset Correction: v_off_ini = 586.939 uV, v_off_fin = 607.181 uV 18:06:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.970 uVs 18:06:25 Integrated Voltage Measurement... 18:06:34 Voltage Offset Correction: v_off_ini = 601.383 uV, v_off_fin = 583.687 uV 18:06:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.411 uVs 18:06:34 Integrated Voltage Measurement... 18:06:43 Voltage Offset Correction: v_off_ini = 566.378 uV, v_off_fin = 589.366 uV 18:06:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.995 uVs 18:06:43 Integrated Voltage Measurement... 18:06:52 Voltage Offset Correction: v_off_ini = 566.767 uV, v_off_fin = 571.394 uV 18:06:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.211 uVs 18:06:52 Integrated Voltage Measurement... 18:07:01 Voltage Offset Correction: v_off_ini = 570.048 uV, v_off_fin = 581.525 uV 18:07:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.304 uVs 18:07:05 I1Y Average and RMS of Measurements VT = -199.875 +- 4.413 uVs I1Y = -39.975 +- 0.883 uTm 18:07:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:07:11 Integrated Voltage Measurement... 18:07:20 Voltage Offset Correction: v_off_ini = 588.852 uV, v_off_fin = 586.291 uV 18:07:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.830 uVs 18:07:20 Integrated Voltage Measurement... 18:07:29 Voltage Offset Correction: v_off_ini = 586.804 uV, v_off_fin = 565.520 uV 18:07:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.949 uVs 18:07:29 Integrated Voltage Measurement... 18:07:38 Voltage Offset Correction: v_off_ini = 563.085 uV, v_off_fin = 561.108 uV 18:07:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.522 uVs 18:07:38 Integrated Voltage Measurement... 18:07:47 Voltage Offset Correction: v_off_ini = 578.332 uV, v_off_fin = 565.974 uV 18:07:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.764 uVs 18:07:47 Integrated Voltage Measurement... 18:07:56 Voltage Offset Correction: v_off_ini = 574.525 uV, v_off_fin = 565.024 uV 18:07:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.318 uVs 18:07:56 Integrated Voltage Measurement... 18:08:05 Voltage Offset Correction: v_off_ini = 572.469 uV, v_off_fin = 583.894 uV 18:08:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.257 uVs 18:08:07 I2X Average and RMS of Measurements VT = -86.273 +- 5.721 uVs I2X = 7.937 +- 0.526 uTm^2 18:08:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:08:12 Integrated Voltage Measurement... 18:08:21 Voltage Offset Correction: v_off_ini = 575.164 uV, v_off_fin = 585.946 uV 18:08:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.502 uVs 18:08:21 Integrated Voltage Measurement... 18:08:30 Voltage Offset Correction: v_off_ini = 581.133 uV, v_off_fin = 550.933 uV 18:08:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.365 uVs 18:08:30 Integrated Voltage Measurement... 18:08:39 Voltage Offset Correction: v_off_ini = 579.221 uV, v_off_fin = 563.099 uV 18:08:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.028 uVs 18:08:39 Integrated Voltage Measurement... 18:08:48 Voltage Offset Correction: v_off_ini = 577.972 uV, v_off_fin = 582.414 uV 18:08:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.424 uVs 18:08:48 Integrated Voltage Measurement... 18:08:57 Voltage Offset Correction: v_off_ini = 561.955 uV, v_off_fin = 557.532 uV 18:08:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -261.511 uVs 18:08:57 Integrated Voltage Measurement... 18:09:06 Voltage Offset Correction: v_off_ini = 572.397 uV, v_off_fin = 565.567 uV 18:09:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.157 uVs 18:09:09 I2Y Average and RMS of Measurements VT = -264.665 +- 0.995 uVs I2Y = -24.350 +- 0.091 uTm^2 18:09:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:09:17 Integrated Voltage Measurement... 18:09:26 Voltage Offset Correction: v_off_ini = 557.161 uV, v_off_fin = 580.883 uV 18:09:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.145 uVs 18:09:26 Integrated Voltage Measurement... 18:09:35 Voltage Offset Correction: v_off_ini = 565.845 uV, v_off_fin = 580.926 uV 18:09:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.543 uVs 18:09:35 Integrated Voltage Measurement... 18:09:44 Voltage Offset Correction: v_off_ini = 574.609 uV, v_off_fin = 566.711 uV 18:09:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.465 uVs 18:09:44 Integrated Voltage Measurement... 18:09:53 Voltage Offset Correction: v_off_ini = 568.949 uV, v_off_fin = 567.225 uV 18:09:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.973 uVs 18:09:53 Integrated Voltage Measurement... 18:10:02 Voltage Offset Correction: v_off_ini = 559.813 uV, v_off_fin = 557.861 uV 18:10:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.674 uVs 18:10:02 Integrated Voltage Measurement... 18:10:11 Voltage Offset Correction: v_off_ini = 540.301 uV, v_off_fin = 558.964 uV 18:10:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.418 uVs 18:10:15 I1X Average and RMS of Measurements VT = -82.370 +- 7.883 uVs I1X = 16.474 +- 1.577 uTm 18:10:17 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:10:22 Integrated Voltage Measurement... 18:10:31 Voltage Offset Correction: v_off_ini = 563.207 uV, v_off_fin = 564.043 uV 18:10:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.365 uVs 18:10:31 Integrated Voltage Measurement... 18:10:40 Voltage Offset Correction: v_off_ini = 564.194 uV, v_off_fin = 589.941 uV 18:10:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.514 uVs 18:10:40 Integrated Voltage Measurement... 18:10:49 Voltage Offset Correction: v_off_ini = 582.023 uV, v_off_fin = 575.525 uV 18:10:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.361 uVs 18:10:49 Integrated Voltage Measurement... 18:10:58 Voltage Offset Correction: v_off_ini = 566.692 uV, v_off_fin = 584.719 uV 18:10:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.875 uVs 18:10:58 Integrated Voltage Measurement... 18:11:06 Voltage Offset Correction: v_off_ini = 562.696 uV, v_off_fin = 552.178 uV 18:11:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.430 uVs 18:11:07 Integrated Voltage Measurement... 18:11:15 Voltage Offset Correction: v_off_ini = 576.632 uV, v_off_fin = 582.127 uV 18:11:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.860 uVs 18:11:20 I1Y Average and RMS of Measurements VT = -205.734 +- 6.466 uVs I1Y = -41.143 +- 1.294 uTm 18:11:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:11:25 Integrated Voltage Measurement... 18:11:34 Voltage Offset Correction: v_off_ini = 571.858 uV, v_off_fin = 560.217 uV 18:11:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.499 uVs 18:11:34 Integrated Voltage Measurement... 18:11:43 Voltage Offset Correction: v_off_ini = 543.545 uV, v_off_fin = 554.440 uV 18:11:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.494 uVs 18:11:43 Integrated Voltage Measurement... 18:11:52 Voltage Offset Correction: v_off_ini = 543.853 uV, v_off_fin = 545.647 uV 18:11:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.307 uVs 18:11:52 Integrated Voltage Measurement... 18:12:01 Voltage Offset Correction: v_off_ini = 568.038 uV, v_off_fin = 565.150 uV 18:12:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.703 uVs 18:12:01 Integrated Voltage Measurement... 18:12:10 Voltage Offset Correction: v_off_ini = 563.900 uV, v_off_fin = 554.509 uV 18:12:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.753 uVs 18:12:10 Integrated Voltage Measurement... 18:12:19 Voltage Offset Correction: v_off_ini = 546.404 uV, v_off_fin = 554.418 uV 18:12:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.691 uVs 18:12:21 I2X Average and RMS of Measurements VT = -89.741 +- 6.075 uVs I2X = 8.256 +- 0.559 uTm^2 18:12:24 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:12:26 Integrated Voltage Measurement... 18:12:35 Voltage Offset Correction: v_off_ini = 559.572 uV, v_off_fin = 577.722 uV 18:12:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.970 uVs 18:12:35 Integrated Voltage Measurement... 18:12:44 Voltage Offset Correction: v_off_ini = 570.366 uV, v_off_fin = 569.434 uV 18:12:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.406 uVs 18:12:44 Integrated Voltage Measurement... 18:12:53 Voltage Offset Correction: v_off_ini = 556.741 uV, v_off_fin = 552.855 uV 18:12:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.135 uVs 18:12:53 Integrated Voltage Measurement... 18:13:02 Voltage Offset Correction: v_off_ini = 562.374 uV, v_off_fin = 563.261 uV 18:13:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.650 uVs 18:13:02 Integrated Voltage Measurement... 18:13:11 Voltage Offset Correction: v_off_ini = 546.714 uV, v_off_fin = 542.937 uV 18:13:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -260.900 uVs 18:13:11 Integrated Voltage Measurement... 18:13:20 Voltage Offset Correction: v_off_ini = 557.412 uV, v_off_fin = 552.164 uV 18:13:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.079 uVs 18:13:23 I2Y Average and RMS of Measurements VT = -252.857 +- 5.128 uVs I2Y = -23.263 +- 0.472 uTm^2 18:13:39 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:13:43 Integrated Voltage Measurement... 18:13:52 Voltage Offset Correction: v_off_ini = 551.213 uV, v_off_fin = 544.198 uV 18:13:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.694 uVs 18:13:52 Integrated Voltage Measurement... 18:14:01 Voltage Offset Correction: v_off_ini = 566.528 uV, v_off_fin = 547.374 uV 18:14:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.223 uVs 18:14:01 Integrated Voltage Measurement... 18:14:10 Voltage Offset Correction: v_off_ini = 566.730 uV, v_off_fin = 565.791 uV 18:14:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.009 uVs 18:14:10 Integrated Voltage Measurement... 18:14:19 Voltage Offset Correction: v_off_ini = 578.895 uV, v_off_fin = 562.446 uV 18:14:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.000 uVs 18:14:19 Integrated Voltage Measurement... 18:14:28 Voltage Offset Correction: v_off_ini = 580.674 uV, v_off_fin = 580.410 uV 18:14:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.592 uVs 18:14:28 Integrated Voltage Measurement... 18:14:37 Voltage Offset Correction: v_off_ini = 581.948 uV, v_off_fin = 580.078 uV 18:14:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.583 uVs 18:14:41 I1X Average and RMS of Measurements VT = -76.517 +- 1.244 uVs I1X = 15.304 +- 0.249 uTm 18:14:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:14:48 Integrated Voltage Measurement... 18:14:57 Voltage Offset Correction: v_off_ini = 601.018 uV, v_off_fin = 585.119 uV 18:14:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.425 uVs 18:14:57 Integrated Voltage Measurement... 18:15:06 Voltage Offset Correction: v_off_ini = 591.826 uV, v_off_fin = 615.017 uV 18:15:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.598 uVs 18:15:06 Integrated Voltage Measurement... 18:15:15 Voltage Offset Correction: v_off_ini = 598.268 uV, v_off_fin = 574.605 uV 18:15:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.933 uVs 18:15:15 Integrated Voltage Measurement... 18:15:24 Voltage Offset Correction: v_off_ini = 580.104 uV, v_off_fin = 606.067 uV 18:15:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.172 uVs 18:15:24 Integrated Voltage Measurement... 18:15:33 Voltage Offset Correction: v_off_ini = 593.953 uV, v_off_fin = 589.600 uV 18:15:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.973 uVs 18:15:33 Integrated Voltage Measurement... 18:15:42 Voltage Offset Correction: v_off_ini = 604.875 uV, v_off_fin = 617.002 uV 18:15:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.621 uVs 18:15:46 I1Y Average and RMS of Measurements VT = -204.454 +- 5.941 uVs I1Y = -40.891 +- 1.188 uTm 18:15:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:15:53 Integrated Voltage Measurement... 18:16:02 Voltage Offset Correction: v_off_ini = 597.532 uV, v_off_fin = 592.381 uV 18:16:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.362 uVs 18:16:02 Integrated Voltage Measurement... 18:16:11 Voltage Offset Correction: v_off_ini = 593.865 uV, v_off_fin = 602.328 uV 18:16:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.871 uVs 18:16:11 Integrated Voltage Measurement... 18:16:20 Voltage Offset Correction: v_off_ini = 612.313 uV, v_off_fin = 591.184 uV 18:16:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.180 uVs 18:16:20 Integrated Voltage Measurement... 18:16:29 Voltage Offset Correction: v_off_ini = 593.179 uV, v_off_fin = 603.801 uV 18:16:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.849 uVs 18:16:29 Integrated Voltage Measurement... 18:16:38 Voltage Offset Correction: v_off_ini = 600.480 uV, v_off_fin = 580.275 uV 18:16:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.636 uVs 18:16:38 Integrated Voltage Measurement... 18:16:47 Voltage Offset Correction: v_off_ini = 593.253 uV, v_off_fin = 592.099 uV 18:16:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.478 uVs 18:16:50 I2X Average and RMS of Measurements VT = -98.896 +- 6.091 uVs I2X = 9.098 +- 0.560 uTm^2 18:16:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:16:58 Integrated Voltage Measurement... 18:17:06 Voltage Offset Correction: v_off_ini = 599.752 uV, v_off_fin = 613.724 uV 18:17:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.585 uVs 18:17:07 Integrated Voltage Measurement... 18:17:15 Voltage Offset Correction: v_off_ini = 622.955 uV, v_off_fin = 624.568 uV 18:17:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.485 uVs 18:17:16 Integrated Voltage Measurement... 18:17:25 Voltage Offset Correction: v_off_ini = 625.226 uV, v_off_fin = 619.591 uV 18:17:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.747 uVs 18:17:25 Integrated Voltage Measurement... 18:17:34 Voltage Offset Correction: v_off_ini = 611.164 uV, v_off_fin = 596.036 uV 18:17:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.816 uVs 18:17:34 Integrated Voltage Measurement... 18:17:43 Voltage Offset Correction: v_off_ini = 611.085 uV, v_off_fin = 621.168 uV 18:17:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.461 uVs 18:17:43 Integrated Voltage Measurement... 18:17:52 Voltage Offset Correction: v_off_ini = 614.518 uV, v_off_fin = 613.535 uV 18:17:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.638 uVs 18:17:54 I2Y Average and RMS of Measurements VT = -259.122 +- 12.967 uVs I2Y = -23.839 +- 1.193 uTm^2 18:17:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:18:03 Integrated Voltage Measurement... 18:18:12 Voltage Offset Correction: v_off_ini = 581.652 uV, v_off_fin = 591.618 uV 18:18:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.642 uVs 18:18:12 Integrated Voltage Measurement... 18:18:21 Voltage Offset Correction: v_off_ini = 599.874 uV, v_off_fin = 596.143 uV 18:18:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.865 uVs 18:18:21 Integrated Voltage Measurement... 18:18:30 Voltage Offset Correction: v_off_ini = 616.418 uV, v_off_fin = 604.246 uV 18:18:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.127 uVs 18:18:30 Integrated Voltage Measurement... 18:18:39 Voltage Offset Correction: v_off_ini = 603.458 uV, v_off_fin = 610.936 uV 18:18:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.243 uVs 18:18:39 Integrated Voltage Measurement... 18:18:48 Voltage Offset Correction: v_off_ini = 623.825 uV, v_off_fin = 608.238 uV 18:18:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.892 uVs 18:18:48 Integrated Voltage Measurement... 18:18:57 Voltage Offset Correction: v_off_ini = 606.860 uV, v_off_fin = 614.250 uV 18:18:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.472 uVs 18:19:01 I1X Average and RMS of Measurements VT = -77.040 +- 9.932 uVs I1X = 15.408 +- 1.986 uTm 18:19:04 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:19:08 Integrated Voltage Measurement... 18:19:17 Voltage Offset Correction: v_off_ini = 629.202 uV, v_off_fin = 602.157 uV 18:19:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.980 uVs 18:19:17 Integrated Voltage Measurement... 18:19:26 Voltage Offset Correction: v_off_ini = 615.931 uV, v_off_fin = 618.048 uV 18:19:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.862 uVs 18:19:26 Integrated Voltage Measurement... 18:19:35 Voltage Offset Correction: v_off_ini = 596.215 uV, v_off_fin = 593.047 uV 18:19:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.554 uVs 18:19:35 Integrated Voltage Measurement... 18:19:44 Voltage Offset Correction: v_off_ini = 598.755 uV, v_off_fin = 607.280 uV 18:19:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.379 uVs 18:19:44 Integrated Voltage Measurement... 18:19:53 Voltage Offset Correction: v_off_ini = 631.700 uV, v_off_fin = 621.401 uV 18:19:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.100 uVs 18:19:53 Integrated Voltage Measurement... 18:20:02 Voltage Offset Correction: v_off_ini = 620.471 uV, v_off_fin = 627.776 uV 18:20:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.840 uVs 18:20:06 I1Y Average and RMS of Measurements VT = -208.286 +- 6.142 uVs I1Y = -41.657 +- 1.228 uTm 18:20:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:20:14 Integrated Voltage Measurement... 18:20:23 Voltage Offset Correction: v_off_ini = 585.515 uV, v_off_fin = 608.769 uV 18:20:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -54.425 uVs 18:20:23 Integrated Voltage Measurement... 18:20:32 Voltage Offset Correction: v_off_ini = 607.483 uV, v_off_fin = 624.320 uV 18:20:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.876 uVs 18:20:32 Integrated Voltage Measurement... 18:20:41 Voltage Offset Correction: v_off_ini = 609.212 uV, v_off_fin = 587.694 uV 18:20:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.447 uVs 18:20:41 Integrated Voltage Measurement... 18:20:50 Voltage Offset Correction: v_off_ini = 588.756 uV, v_off_fin = 624.906 uV 18:20:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.982 uVs 18:20:50 Integrated Voltage Measurement... 18:20:59 Voltage Offset Correction: v_off_ini = 608.016 uV, v_off_fin = 584.855 uV 18:20:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.805 uVs 18:20:59 Integrated Voltage Measurement... 18:21:08 Voltage Offset Correction: v_off_ini = 622.253 uV, v_off_fin = 641.528 uV 18:21:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.126 uVs 18:21:10 I2X Average and RMS of Measurements VT = -85.943 +- 11.053 uVs I2X = 7.907 +- 1.017 uTm^2 18:21:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:21:18 Integrated Voltage Measurement... 18:21:27 Voltage Offset Correction: v_off_ini = 632.879 uV, v_off_fin = 629.583 uV 18:21:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.531 uVs 18:21:27 Integrated Voltage Measurement... 18:21:36 Voltage Offset Correction: v_off_ini = 645.819 uV, v_off_fin = 641.968 uV 18:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.925 uVs 18:21:36 Integrated Voltage Measurement... 18:21:45 Voltage Offset Correction: v_off_ini = 635.278 uV, v_off_fin = 631.604 uV 18:21:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.554 uVs 18:21:45 Integrated Voltage Measurement... 18:21:54 Voltage Offset Correction: v_off_ini = 613.095 uV, v_off_fin = 623.705 uV 18:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.459 uVs 18:21:54 Integrated Voltage Measurement... 18:22:03 Voltage Offset Correction: v_off_ini = 636.622 uV, v_off_fin = 625.649 uV 18:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.324 uVs 18:22:03 Integrated Voltage Measurement... 18:22:12 Voltage Offset Correction: v_off_ini = 651.881 uV, v_off_fin = 634.606 uV 18:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.707 uVs 18:22:14 I2Y Average and RMS of Measurements VT = -260.417 +- 5.112 uVs I2Y = -23.958 +- 0.470 uTm^2 18:22:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:22:23 Integrated Voltage Measurement... 18:22:32 Voltage Offset Correction: v_off_ini = 661.145 uV, v_off_fin = 650.677 uV 18:22:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.136 uVs 18:22:32 Integrated Voltage Measurement... 18:22:41 Voltage Offset Correction: v_off_ini = 678.981 uV, v_off_fin = 661.392 uV 18:22:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.107 uVs 18:22:41 Integrated Voltage Measurement... 18:22:50 Voltage Offset Correction: v_off_ini = 670.709 uV, v_off_fin = 666.539 uV 18:22:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.986 uVs 18:22:50 Integrated Voltage Measurement... 18:22:59 Voltage Offset Correction: v_off_ini = 677.121 uV, v_off_fin = 684.452 uV 18:22:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.055 uVs 18:22:59 Integrated Voltage Measurement... 18:23:08 Voltage Offset Correction: v_off_ini = 675.210 uV, v_off_fin = 667.773 uV 18:23:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.830 uVs 18:23:08 Integrated Voltage Measurement... 18:23:17 Voltage Offset Correction: v_off_ini = 676.726 uV, v_off_fin = 657.331 uV 18:23:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.225 uVs 18:23:22 I1X Average and RMS of Measurements VT = -76.890 +- 3.491 uVs I1X = 15.378 +- 0.698 uTm 18:23:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:23:28 Integrated Voltage Measurement... 18:23:37 Voltage Offset Correction: v_off_ini = 644.047 uV, v_off_fin = 651.167 uV 18:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -187.556 uVs 18:23:37 Integrated Voltage Measurement... 18:23:46 Voltage Offset Correction: v_off_ini = 648.819 uV, v_off_fin = 668.291 uV 18:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.334 uVs 18:23:46 Integrated Voltage Measurement... 18:23:55 Voltage Offset Correction: v_off_ini = 648.253 uV, v_off_fin = 652.723 uV 18:23:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.103 uVs 18:23:56 Integrated Voltage Measurement... 18:24:04 Voltage Offset Correction: v_off_ini = 653.802 uV, v_off_fin = 680.864 uV 18:24:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.254 uVs 18:24:05 Integrated Voltage Measurement... 18:24:13 Voltage Offset Correction: v_off_ini = 661.109 uV, v_off_fin = 652.847 uV 18:24:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.834 uVs 18:24:14 Integrated Voltage Measurement... 18:24:22 Voltage Offset Correction: v_off_ini = 649.127 uV, v_off_fin = 663.308 uV 18:24:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.292 uVs 18:24:27 I1Y Average and RMS of Measurements VT = -200.562 +- 6.119 uVs I1Y = -40.113 +- 1.223 uTm 18:24:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:24:34 Integrated Voltage Measurement... 18:24:43 Voltage Offset Correction: v_off_ini = 656.886 uV, v_off_fin = 655.265 uV 18:24:43 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -133.111 uVs 18:24:43 Integrated Voltage Measurement... 18:24:52 Voltage Offset Correction: v_off_ini = 627.786 uV, v_off_fin = 633.916 uV 18:24:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.540 uVs 18:24:52 Integrated Voltage Measurement... 18:25:01 Voltage Offset Correction: v_off_ini = 640.747 uV, v_off_fin = 635.338 uV 18:25:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.408 uVs 18:25:02 Integrated Voltage Measurement... 18:25:11 Voltage Offset Correction: v_off_ini = 636.674 uV, v_off_fin = 646.347 uV 18:25:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.135 uVs 18:25:11 Integrated Voltage Measurement... 18:25:20 Voltage Offset Correction: v_off_ini = 632.419 uV, v_off_fin = 626.656 uV 18:25:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.017 uVs 18:25:20 Integrated Voltage Measurement... 18:25:29 Voltage Offset Correction: v_off_ini = 629.725 uV, v_off_fin = 634.852 uV 18:25:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.985 uVs 18:25:31 I2X Average and RMS of Measurements VT = -95.699 +- 5.789 uVs I2X = 8.804 +- 0.532 uTm^2 18:25:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:25:39 Integrated Voltage Measurement... 18:25:48 Voltage Offset Correction: v_off_ini = 597.855 uV, v_off_fin = 611.177 uV 18:25:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.153 uVs 18:25:48 Integrated Voltage Measurement... 18:25:57 Voltage Offset Correction: v_off_ini = 614.973 uV, v_off_fin = 618.608 uV 18:25:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.449 uVs 18:25:57 Integrated Voltage Measurement... 18:26:06 Voltage Offset Correction: v_off_ini = 607.696 uV, v_off_fin = 615.210 uV 18:26:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.165 uVs 18:26:06 Integrated Voltage Measurement... 18:26:15 Voltage Offset Correction: v_off_ini = 634.730 uV, v_off_fin = 651.280 uV 18:26:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.792 uVs 18:26:15 Integrated Voltage Measurement... 18:26:24 Voltage Offset Correction: v_off_ini = 629.805 uV, v_off_fin = 625.399 uV 18:26:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.257 uVs 18:26:24 Integrated Voltage Measurement... 18:26:33 Voltage Offset Correction: v_off_ini = 608.246 uV, v_off_fin = 625.312 uV 18:26:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.151 uVs 18:26:35 I2Y Average and RMS of Measurements VT = -252.661 +- 2.156 uVs I2Y = -23.245 +- 0.198 uTm^2 18:26:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:26:44 Integrated Voltage Measurement... 18:26:53 Voltage Offset Correction: v_off_ini = 667.333 uV, v_off_fin = 649.339 uV 18:26:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -54.413 uVs 18:26:53 Integrated Voltage Measurement... 18:27:02 Voltage Offset Correction: v_off_ini = 650.880 uV, v_off_fin = 649.902 uV 18:27:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.419 uVs 18:27:02 Integrated Voltage Measurement... 18:27:11 Voltage Offset Correction: v_off_ini = 649.431 uV, v_off_fin = 656.966 uV 18:27:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.744 uVs 18:27:11 Integrated Voltage Measurement... 18:27:20 Voltage Offset Correction: v_off_ini = 649.397 uV, v_off_fin = 630.536 uV 18:27:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.192 uVs 18:27:20 Integrated Voltage Measurement... 18:27:29 Voltage Offset Correction: v_off_ini = 632.891 uV, v_off_fin = 638.002 uV 18:27:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.516 uVs 18:27:29 Integrated Voltage Measurement... 18:27:38 Voltage Offset Correction: v_off_ini = 638.502 uV, v_off_fin = 665.246 uV 18:27:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.884 uVs 18:27:43 I1X Average and RMS of Measurements VT = -87.528 +- 10.228 uVs I1X = 17.506 +- 2.045 uTm 18:27:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:27:49 Integrated Voltage Measurement... 18:27:58 Voltage Offset Correction: v_off_ini = 667.227 uV, v_off_fin = 659.990 uV 18:27:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.504 uVs 18:27:58 Integrated Voltage Measurement... 18:28:07 Voltage Offset Correction: v_off_ini = 659.475 uV, v_off_fin = 675.666 uV 18:28:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.000 uVs 18:28:08 Integrated Voltage Measurement... 18:28:16 Voltage Offset Correction: v_off_ini = 667.387 uV, v_off_fin = 659.362 uV 18:28:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.920 uVs 18:28:17 Integrated Voltage Measurement... 18:28:25 Voltage Offset Correction: v_off_ini = 650.904 uV, v_off_fin = 662.932 uV 18:28:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.044 uVs 18:28:26 Integrated Voltage Measurement... 18:28:34 Voltage Offset Correction: v_off_ini = 657.924 uV, v_off_fin = 635.034 uV 18:28:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.510 uVs 18:28:34 Integrated Voltage Measurement... 18:28:43 Voltage Offset Correction: v_off_ini = 655.180 uV, v_off_fin = 674.207 uV 18:28:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.822 uVs 18:28:48 I1Y Average and RMS of Measurements VT = -199.800 +- 9.362 uVs I1Y = -39.960 +- 1.872 uTm 18:28:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:28:55 Integrated Voltage Measurement... 18:29:04 Voltage Offset Correction: v_off_ini = 666.243 uV, v_off_fin = 676.629 uV 18:29:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.382 uVs 18:29:04 Integrated Voltage Measurement... 18:29:13 Voltage Offset Correction: v_off_ini = 690.162 uV, v_off_fin = 696.856 uV 18:29:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.107 uVs 18:29:14 Integrated Voltage Measurement... 18:29:22 Voltage Offset Correction: v_off_ini = 692.032 uV, v_off_fin = 679.890 uV 18:29:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.926 uVs 18:29:23 Integrated Voltage Measurement... 18:29:32 Voltage Offset Correction: v_off_ini = 698.327 uV, v_off_fin = 709.887 uV 18:29:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.347 uVs 18:29:32 Integrated Voltage Measurement... 18:29:41 Voltage Offset Correction: v_off_ini = 686.065 uV, v_off_fin = 696.498 uV 18:29:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.808 uVs 18:29:41 Integrated Voltage Measurement... 18:29:50 Voltage Offset Correction: v_off_ini = 723.066 uV, v_off_fin = 714.228 uV 18:29:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.065 uVs 18:29:52 I2X Average and RMS of Measurements VT = -96.272 +- 8.371 uVs I2X = 8.857 +- 0.770 uTm^2 18:29:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:30:00 Integrated Voltage Measurement... 18:30:09 Voltage Offset Correction: v_off_ini = 680.041 uV, v_off_fin = 689.613 uV 18:30:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.040 uVs 18:30:09 Integrated Voltage Measurement... 18:30:18 Voltage Offset Correction: v_off_ini = 695.293 uV, v_off_fin = 704.668 uV 18:30:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.413 uVs 18:30:18 Integrated Voltage Measurement... 18:30:27 Voltage Offset Correction: v_off_ini = 696.797 uV, v_off_fin = 678.914 uV 18:30:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.727 uVs 18:30:27 Integrated Voltage Measurement... 18:30:36 Voltage Offset Correction: v_off_ini = 690.326 uV, v_off_fin = 695.975 uV 18:30:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.774 uVs 18:30:36 Integrated Voltage Measurement... 18:30:45 Voltage Offset Correction: v_off_ini = 693.021 uV, v_off_fin = 678.750 uV 18:30:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.327 uVs 18:30:45 Integrated Voltage Measurement... 18:30:54 Voltage Offset Correction: v_off_ini = 666.781 uV, v_off_fin = 690.783 uV 18:30:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.605 uVs 18:30:56 I2Y Average and RMS of Measurements VT = -255.314 +- 8.621 uVs I2Y = -23.489 +- 0.793 uTm^2 18:31:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:31:05 Integrated Voltage Measurement... 18:31:14 Voltage Offset Correction: v_off_ini = 685.896 uV, v_off_fin = 687.135 uV 18:31:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.180 uVs 18:31:14 Integrated Voltage Measurement... 18:31:23 Voltage Offset Correction: v_off_ini = 654.744 uV, v_off_fin = 653.999 uV 18:31:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.439 uVs 18:31:23 Integrated Voltage Measurement... 18:31:32 Voltage Offset Correction: v_off_ini = 665.934 uV, v_off_fin = 659.300 uV 18:31:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.073 uVs 18:31:32 Integrated Voltage Measurement... 18:31:41 Voltage Offset Correction: v_off_ini = 655.187 uV, v_off_fin = 673.168 uV 18:31:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.999 uVs 18:31:41 Integrated Voltage Measurement... 18:31:50 Voltage Offset Correction: v_off_ini = 651.352 uV, v_off_fin = 656.155 uV 18:31:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.229 uVs 18:31:50 Integrated Voltage Measurement... 18:31:59 Voltage Offset Correction: v_off_ini = 668.499 uV, v_off_fin = 676.474 uV 18:31:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.418 uVs 18:32:04 I1X Average and RMS of Measurements VT = -87.723 +- 14.553 uVs I1X = 17.545 +- 2.910 uTm 18:32:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:32:10 Integrated Voltage Measurement... 18:32:19 Voltage Offset Correction: v_off_ini = 673.425 uV, v_off_fin = 660.531 uV 18:32:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -197.576 uVs 18:32:19 Integrated Voltage Measurement... 18:32:28 Voltage Offset Correction: v_off_ini = 654.413 uV, v_off_fin = 671.079 uV 18:32:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.568 uVs 18:32:28 Integrated Voltage Measurement... 18:32:37 Voltage Offset Correction: v_off_ini = 662.116 uV, v_off_fin = 654.144 uV 18:32:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.422 uVs 18:32:37 Integrated Voltage Measurement... 18:32:46 Voltage Offset Correction: v_off_ini = 655.515 uV, v_off_fin = 672.268 uV 18:32:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.337 uVs 18:32:46 Integrated Voltage Measurement... 18:32:55 Voltage Offset Correction: v_off_ini = 654.184 uV, v_off_fin = 656.547 uV 18:32:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.742 uVs 18:32:55 Integrated Voltage Measurement... 18:33:04 Voltage Offset Correction: v_off_ini = 659.612 uV, v_off_fin = 654.711 uV 18:33:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.019 uVs 18:33:09 I1Y Average and RMS of Measurements VT = -199.111 +- 4.760 uVs I1Y = -39.823 +- 0.953 uTm 18:33:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:33:16 Integrated Voltage Measurement... 18:33:25 Voltage Offset Correction: v_off_ini = 640.280 uV, v_off_fin = 647.047 uV 18:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.324 uVs 18:33:25 Integrated Voltage Measurement... 18:33:34 Voltage Offset Correction: v_off_ini = 643.829 uV, v_off_fin = 657.770 uV 18:33:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.523 uVs 18:33:34 Integrated Voltage Measurement... 18:33:43 Voltage Offset Correction: v_off_ini = 674.673 uV, v_off_fin = 623.066 uV 18:33:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.167 uVs 18:33:44 Integrated Voltage Measurement... 18:33:53 Voltage Offset Correction: v_off_ini = 637.725 uV, v_off_fin = 639.532 uV 18:33:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.988 uVs 18:33:53 Integrated Voltage Measurement... 18:34:02 Voltage Offset Correction: v_off_ini = 640.765 uV, v_off_fin = 630.472 uV 18:34:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.300 uVs 18:34:02 Integrated Voltage Measurement... 18:34:11 Voltage Offset Correction: v_off_ini = 649.912 uV, v_off_fin = 653.563 uV 18:34:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.456 uVs 18:34:13 I2X Average and RMS of Measurements VT = -80.960 +- 3.623 uVs I2X = 7.448 +- 0.333 uTm^2 18:34:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:34:21 Integrated Voltage Measurement... 18:34:30 Voltage Offset Correction: v_off_ini = 655.680 uV, v_off_fin = 667.465 uV 18:34:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.631 uVs 18:34:30 Integrated Voltage Measurement... 18:34:39 Voltage Offset Correction: v_off_ini = 655.576 uV, v_off_fin = 673.986 uV 18:34:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.906 uVs 18:34:39 Integrated Voltage Measurement... 18:34:48 Voltage Offset Correction: v_off_ini = 653.800 uV, v_off_fin = 647.516 uV 18:34:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.702 uVs 18:34:48 Integrated Voltage Measurement... 18:34:57 Voltage Offset Correction: v_off_ini = 659.793 uV, v_off_fin = 668.869 uV 18:34:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.239 uVs 18:34:57 Integrated Voltage Measurement... 18:35:06 Voltage Offset Correction: v_off_ini = 664.183 uV, v_off_fin = 665.873 uV 18:35:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.900 uVs 18:35:06 Integrated Voltage Measurement... 18:35:15 Voltage Offset Correction: v_off_ini = 664.356 uV, v_off_fin = 675.927 uV 18:35:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.715 uVs 18:35:17 I2Y Average and RMS of Measurements VT = -255.349 +- 8.293 uVs I2Y = -23.492 +- 0.763 uTm^2 18:35:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:35:29 Integrated Voltage Measurement... 18:35:38 Voltage Offset Correction: v_off_ini = 675.869 uV, v_off_fin = 677.089 uV 18:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.558 uVs 18:35:38 Integrated Voltage Measurement... 18:35:47 Voltage Offset Correction: v_off_ini = 663.036 uV, v_off_fin = 679.753 uV 18:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.510 uVs 18:35:48 Integrated Voltage Measurement... 18:35:56 Voltage Offset Correction: v_off_ini = 674.878 uV, v_off_fin = 680.071 uV 18:35:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.522 uVs 18:35:57 Integrated Voltage Measurement... 18:36:05 Voltage Offset Correction: v_off_ini = 686.682 uV, v_off_fin = 694.276 uV 18:36:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.025 uVs 18:36:06 Integrated Voltage Measurement... 18:36:15 Voltage Offset Correction: v_off_ini = 679.119 uV, v_off_fin = 699.581 uV 18:36:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.864 uVs 18:36:15 Integrated Voltage Measurement... 18:36:24 Voltage Offset Correction: v_off_ini = 691.854 uV, v_off_fin = 677.354 uV 18:36:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.000 uVs 18:36:28 I1X Average and RMS of Measurements VT = -83.747 +- 12.009 uVs I1X = 16.750 +- 2.402 uTm 18:36:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:36:35 Integrated Voltage Measurement... 18:36:44 Voltage Offset Correction: v_off_ini = 683.945 uV, v_off_fin = 678.924 uV 18:36:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.097 uVs 18:36:44 Integrated Voltage Measurement... 18:36:53 Voltage Offset Correction: v_off_ini = 695.017 uV, v_off_fin = 699.139 uV 18:36:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.758 uVs 18:36:53 Integrated Voltage Measurement... 18:37:02 Voltage Offset Correction: v_off_ini = 689.255 uV, v_off_fin = 676.624 uV 18:37:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.781 uVs 18:37:02 Integrated Voltage Measurement... 18:37:11 Voltage Offset Correction: v_off_ini = 706.946 uV, v_off_fin = 705.815 uV 18:37:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.530 uVs 18:37:11 Integrated Voltage Measurement... 18:37:20 Voltage Offset Correction: v_off_ini = 691.615 uV, v_off_fin = 668.106 uV 18:37:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.453 uVs 18:37:20 Integrated Voltage Measurement... 18:37:29 Voltage Offset Correction: v_off_ini = 671.184 uV, v_off_fin = 673.324 uV 18:37:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.665 uVs 18:37:33 I1Y Average and RMS of Measurements VT = -205.047 +- 2.565 uVs I1Y = -41.009 +- 0.513 uTm 18:37:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:37:38 Integrated Voltage Measurement... 18:37:47 Voltage Offset Correction: v_off_ini = 673.368 uV, v_off_fin = 660.429 uV 18:37:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.318 uVs 18:37:47 Integrated Voltage Measurement... 18:37:56 Voltage Offset Correction: v_off_ini = 653.019 uV, v_off_fin = 662.625 uV 18:37:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.444 uVs 18:37:56 Integrated Voltage Measurement... 18:38:05 Voltage Offset Correction: v_off_ini = 661.975 uV, v_off_fin = 660.198 uV 18:38:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.030 uVs 18:38:05 Integrated Voltage Measurement... 18:38:14 Voltage Offset Correction: v_off_ini = 665.212 uV, v_off_fin = 657.756 uV 18:38:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.304 uVs 18:38:14 Integrated Voltage Measurement... 18:38:23 Voltage Offset Correction: v_off_ini = 669.622 uV, v_off_fin = 661.590 uV 18:38:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.051 uVs 18:38:23 Integrated Voltage Measurement... 18:38:32 Voltage Offset Correction: v_off_ini = 662.407 uV, v_off_fin = 659.442 uV 18:38:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.592 uVs 18:38:35 I2X Average and RMS of Measurements VT = -90.790 +- 2.550 uVs I2X = 8.353 +- 0.235 uTm^2 18:38:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:38:40 Integrated Voltage Measurement... 18:38:49 Voltage Offset Correction: v_off_ini = 655.312 uV, v_off_fin = 673.255 uV 18:38:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.504 uVs 18:38:49 Integrated Voltage Measurement... 18:38:58 Voltage Offset Correction: v_off_ini = 650.058 uV, v_off_fin = 657.433 uV 18:38:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.820 uVs 18:38:58 Integrated Voltage Measurement... 18:39:07 Voltage Offset Correction: v_off_ini = 641.627 uV, v_off_fin = 631.175 uV 18:39:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.882 uVs 18:39:07 Integrated Voltage Measurement... 18:39:16 Voltage Offset Correction: v_off_ini = 636.127 uV, v_off_fin = 647.718 uV 18:39:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.431 uVs 18:39:16 Integrated Voltage Measurement... 18:39:25 Voltage Offset Correction: v_off_ini = 651.307 uV, v_off_fin = 669.424 uV 18:39:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.047 uVs 18:39:25 Integrated Voltage Measurement... 18:39:34 Voltage Offset Correction: v_off_ini = 670.873 uV, v_off_fin = 662.630 uV 18:39:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.131 uVs 18:39:36 I2Y Average and RMS of Measurements VT = -255.969 +- 7.787 uVs I2Y = -23.549 +- 0.716 uTm^2 18:39:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:39:45 Integrated Voltage Measurement... 18:39:54 Voltage Offset Correction: v_off_ini = 660.740 uV, v_off_fin = 656.610 uV 18:39:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.250 uVs 18:39:54 Integrated Voltage Measurement... 18:40:03 Voltage Offset Correction: v_off_ini = 662.046 uV, v_off_fin = 664.329 uV 18:40:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.534 uVs 18:40:03 Integrated Voltage Measurement... 18:40:12 Voltage Offset Correction: v_off_ini = 664.851 uV, v_off_fin = 664.946 uV 18:40:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.756 uVs 18:40:12 Integrated Voltage Measurement... 18:40:21 Voltage Offset Correction: v_off_ini = 665.335 uV, v_off_fin = 672.578 uV 18:40:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.874 uVs 18:40:21 Integrated Voltage Measurement... 18:40:30 Voltage Offset Correction: v_off_ini = 681.299 uV, v_off_fin = 668.603 uV 18:40:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.540 uVs 18:40:30 Integrated Voltage Measurement... 18:40:39 Voltage Offset Correction: v_off_ini = 666.293 uV, v_off_fin = 658.858 uV 18:40:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.764 uVs 18:40:43 I1X Average and RMS of Measurements VT = -86.953 +- 5.273 uVs I1X = 17.391 +- 1.055 uTm 18:40:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:40:50 Integrated Voltage Measurement... 18:40:59 Voltage Offset Correction: v_off_ini = 667.190 uV, v_off_fin = 659.903 uV 18:40:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.667 uVs 18:40:59 Integrated Voltage Measurement... 18:41:08 Voltage Offset Correction: v_off_ini = 686.046 uV, v_off_fin = 689.435 uV 18:41:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.380 uVs 18:41:08 Integrated Voltage Measurement... 18:41:17 Voltage Offset Correction: v_off_ini = 689.273 uV, v_off_fin = 682.246 uV 18:41:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.682 uVs 18:41:17 Integrated Voltage Measurement... 18:41:26 Voltage Offset Correction: v_off_ini = 684.409 uV, v_off_fin = 684.979 uV 18:41:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.312 uVs 18:41:26 Integrated Voltage Measurement... 18:41:35 Voltage Offset Correction: v_off_ini = 659.069 uV, v_off_fin = 661.140 uV 18:41:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.411 uVs 18:41:35 Integrated Voltage Measurement... 18:41:44 Voltage Offset Correction: v_off_ini = 649.204 uV, v_off_fin = 664.616 uV 18:41:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.649 uVs 18:41:48 I1Y Average and RMS of Measurements VT = -202.183 +- 4.189 uVs I1Y = -40.437 +- 0.838 uTm 18:41:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:41:53 Integrated Voltage Measurement... 18:42:02 Voltage Offset Correction: v_off_ini = 658.266 uV, v_off_fin = 663.237 uV 18:42:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.181 uVs 18:42:02 Integrated Voltage Measurement... 18:42:11 Voltage Offset Correction: v_off_ini = 650.193 uV, v_off_fin = 643.581 uV 18:42:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.215 uVs 18:42:11 Integrated Voltage Measurement... 18:42:20 Voltage Offset Correction: v_off_ini = 650.369 uV, v_off_fin = 643.306 uV 18:42:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.312 uVs 18:42:20 Integrated Voltage Measurement... 18:42:29 Voltage Offset Correction: v_off_ini = 639.552 uV, v_off_fin = 670.656 uV 18:42:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.929 uVs 18:42:29 Integrated Voltage Measurement... 18:42:38 Voltage Offset Correction: v_off_ini = 660.953 uV, v_off_fin = 643.432 uV 18:42:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.639 uVs 18:42:39 Integrated Voltage Measurement... 18:42:47 Voltage Offset Correction: v_off_ini = 645.907 uV, v_off_fin = 640.247 uV 18:42:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.735 uVs 18:42:50 I2X Average and RMS of Measurements VT = -98.502 +- 14.525 uVs I2X = 9.062 +- 1.336 uTm^2 18:42:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:42:55 Integrated Voltage Measurement... 18:43:04 Voltage Offset Correction: v_off_ini = 659.576 uV, v_off_fin = 644.441 uV 18:43:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.380 uVs 18:43:04 Integrated Voltage Measurement... 18:43:13 Voltage Offset Correction: v_off_ini = 645.757 uV, v_off_fin = 648.646 uV 18:43:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.995 uVs 18:43:13 Integrated Voltage Measurement... 18:43:22 Voltage Offset Correction: v_off_ini = 641.500 uV, v_off_fin = 627.546 uV 18:43:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.182 uVs 18:43:22 Integrated Voltage Measurement... 18:43:31 Voltage Offset Correction: v_off_ini = 635.661 uV, v_off_fin = 642.715 uV 18:43:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.767 uVs 18:43:31 Integrated Voltage Measurement... 18:43:40 Voltage Offset Correction: v_off_ini = 634.067 uV, v_off_fin = 647.196 uV 18:43:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.581 uVs 18:43:40 Integrated Voltage Measurement... 18:43:49 Voltage Offset Correction: v_off_ini = 644.862 uV, v_off_fin = 641.645 uV 18:43:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.223 uVs 18:43:52 I2Y Average and RMS of Measurements VT = -264.021 +- 6.261 uVs I2Y = -24.290 +- 0.576 uTm^2 18:43:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:44:00 Integrated Voltage Measurement... 18:44:09 Voltage Offset Correction: v_off_ini = 663.181 uV, v_off_fin = 656.671 uV 18:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.260 uVs 18:44:09 Integrated Voltage Measurement... 18:44:18 Voltage Offset Correction: v_off_ini = 655.141 uV, v_off_fin = 681.232 uV 18:44:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.518 uVs 18:44:18 Integrated Voltage Measurement... 18:44:27 Voltage Offset Correction: v_off_ini = 672.874 uV, v_off_fin = 668.611 uV 18:44:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.754 uVs 18:44:27 Integrated Voltage Measurement... 18:44:36 Voltage Offset Correction: v_off_ini = 672.298 uV, v_off_fin = 670.158 uV 18:44:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.251 uVs 18:44:36 Integrated Voltage Measurement... 18:44:45 Voltage Offset Correction: v_off_ini = 656.972 uV, v_off_fin = 664.125 uV 18:44:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.922 uVs 18:44:45 Integrated Voltage Measurement... 18:44:54 Voltage Offset Correction: v_off_ini = 672.104 uV, v_off_fin = 667.020 uV 18:44:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.232 uVs 18:44:58 I1X Average and RMS of Measurements VT = -76.489 +- 5.641 uVs I1X = 15.298 +- 1.128 uTm 18:45:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:45:05 Integrated Voltage Measurement... 18:45:14 Voltage Offset Correction: v_off_ini = 658.402 uV, v_off_fin = 652.933 uV 18:45:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -204.093 uVs 18:45:14 Integrated Voltage Measurement... 18:45:23 Voltage Offset Correction: v_off_ini = 646.327 uV, v_off_fin = 651.141 uV 18:45:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.339 uVs 18:45:23 Integrated Voltage Measurement... 18:45:32 Voltage Offset Correction: v_off_ini = 637.853 uV, v_off_fin = 634.938 uV 18:45:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.898 uVs 18:45:32 Integrated Voltage Measurement... 18:45:41 Voltage Offset Correction: v_off_ini = 645.476 uV, v_off_fin = 667.119 uV 18:45:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.796 uVs 18:45:41 Integrated Voltage Measurement... 18:45:50 Voltage Offset Correction: v_off_ini = 645.161 uV, v_off_fin = 644.131 uV 18:45:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.294 uVs 18:45:50 Integrated Voltage Measurement... 18:45:59 Voltage Offset Correction: v_off_ini = 640.954 uV, v_off_fin = 651.058 uV 18:45:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.603 uVs 18:46:03 I1Y Average and RMS of Measurements VT = -196.504 +- 4.042 uVs I1Y = -39.300 +- 0.809 uTm 18:46:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:46:09 Integrated Voltage Measurement... 18:46:18 Voltage Offset Correction: v_off_ini = 640.052 uV, v_off_fin = 611.778 uV 18:46:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.685 uVs 18:46:18 Integrated Voltage Measurement... 18:46:27 Voltage Offset Correction: v_off_ini = 614.916 uV, v_off_fin = 623.789 uV 18:46:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.097 uVs 18:46:27 Integrated Voltage Measurement... 18:46:36 Voltage Offset Correction: v_off_ini = 626.448 uV, v_off_fin = 619.177 uV 18:46:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.274 uVs 18:46:36 Integrated Voltage Measurement... 18:46:45 Voltage Offset Correction: v_off_ini = 621.265 uV, v_off_fin = 619.855 uV 18:46:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.491 uVs 18:46:45 Integrated Voltage Measurement... 18:46:54 Voltage Offset Correction: v_off_ini = 619.268 uV, v_off_fin = 632.911 uV 18:46:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -105.502 uVs 18:46:54 Integrated Voltage Measurement... 18:47:03 Voltage Offset Correction: v_off_ini = 648.856 uV, v_off_fin = 645.283 uV 18:47:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.091 uVs 18:47:05 I2X Average and RMS of Measurements VT = -91.190 +- 6.357 uVs I2X = 8.390 +- 0.585 uTm^2 18:47:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:47:10 Integrated Voltage Measurement... 18:47:19 Voltage Offset Correction: v_off_ini = 633.075 uV, v_off_fin = 633.297 uV 18:47:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.169 uVs 18:47:19 Integrated Voltage Measurement... 18:47:28 Voltage Offset Correction: v_off_ini = 630.535 uV, v_off_fin = 645.027 uV 18:47:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.868 uVs 18:47:28 Integrated Voltage Measurement... 18:47:37 Voltage Offset Correction: v_off_ini = 630.339 uV, v_off_fin = 628.955 uV 18:47:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.843 uVs 18:47:37 Integrated Voltage Measurement... 18:47:46 Voltage Offset Correction: v_off_ini = 646.430 uV, v_off_fin = 633.014 uV 18:47:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.915 uVs 18:47:47 Integrated Voltage Measurement... 18:47:55 Voltage Offset Correction: v_off_ini = 632.847 uV, v_off_fin = 634.688 uV 18:47:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.732 uVs 18:47:56 Integrated Voltage Measurement... 18:48:05 Voltage Offset Correction: v_off_ini = 640.077 uV, v_off_fin = 634.077 uV 18:48:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.482 uVs 18:48:07 I2Y Average and RMS of Measurements VT = -250.835 +- 11.727 uVs I2Y = -23.077 +- 1.079 uTm^2 18:48:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:48:15 Integrated Voltage Measurement... 18:48:24 Voltage Offset Correction: v_off_ini = 628.879 uV, v_off_fin = 621.343 uV 18:48:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.627 uVs 18:48:24 Integrated Voltage Measurement... 18:48:33 Voltage Offset Correction: v_off_ini = 644.363 uV, v_off_fin = 631.981 uV 18:48:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.907 uVs 18:48:33 Integrated Voltage Measurement... 18:48:42 Voltage Offset Correction: v_off_ini = 627.448 uV, v_off_fin = 635.827 uV 18:48:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.536 uVs 18:48:42 Integrated Voltage Measurement... 18:48:51 Voltage Offset Correction: v_off_ini = 620.484 uV, v_off_fin = 634.788 uV 18:48:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.862 uVs 18:48:51 Integrated Voltage Measurement... 18:49:00 Voltage Offset Correction: v_off_ini = 624.103 uV, v_off_fin = 623.249 uV 18:49:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.688 uVs 18:49:00 Integrated Voltage Measurement... 18:49:09 Voltage Offset Correction: v_off_ini = 655.564 uV, v_off_fin = 642.958 uV 18:49:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.085 uVs 18:49:14 I1X Average and RMS of Measurements VT = -69.784 +- 8.573 uVs I1X = 13.957 +- 1.714 uTm 18:49:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:49:20 Integrated Voltage Measurement... 18:49:29 Voltage Offset Correction: v_off_ini = 638.573 uV, v_off_fin = 641.333 uV 18:49:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -192.565 uVs 18:49:29 Integrated Voltage Measurement... 18:49:38 Voltage Offset Correction: v_off_ini = 650.473 uV, v_off_fin = 660.679 uV 18:49:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.837 uVs 18:49:38 Integrated Voltage Measurement... 18:49:47 Voltage Offset Correction: v_off_ini = 657.669 uV, v_off_fin = 644.793 uV 18:49:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.200 uVs 18:49:47 Integrated Voltage Measurement... 18:49:56 Voltage Offset Correction: v_off_ini = 662.219 uV, v_off_fin = 671.302 uV 18:49:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.772 uVs 18:49:56 Integrated Voltage Measurement... 18:50:05 Voltage Offset Correction: v_off_ini = 650.194 uV, v_off_fin = 649.253 uV 18:50:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.698 uVs 18:50:05 Integrated Voltage Measurement... 18:50:14 Voltage Offset Correction: v_off_ini = 664.982 uV, v_off_fin = 663.126 uV 18:50:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.441 uVs 18:50:19 I1Y Average and RMS of Measurements VT = -194.085 +- 4.109 uVs I1Y = -38.818 +- 0.823 uTm 18:50:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:50:24 Integrated Voltage Measurement... 18:50:33 Voltage Offset Correction: v_off_ini = 659.857 uV, v_off_fin = 643.654 uV 18:50:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.707 uVs 18:50:33 Integrated Voltage Measurement... 18:50:42 Voltage Offset Correction: v_off_ini = 657.182 uV, v_off_fin = 661.050 uV 18:50:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.888 uVs 18:50:42 Integrated Voltage Measurement... 18:50:51 Voltage Offset Correction: v_off_ini = 654.978 uV, v_off_fin = 620.210 uV 18:50:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.980 uVs 18:50:51 Integrated Voltage Measurement... 18:51:00 Voltage Offset Correction: v_off_ini = 633.724 uV, v_off_fin = 639.698 uV 18:51:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.917 uVs 18:51:00 Integrated Voltage Measurement... 18:51:09 Voltage Offset Correction: v_off_ini = 632.951 uV, v_off_fin = 629.313 uV 18:51:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.916 uVs 18:51:09 Integrated Voltage Measurement... 18:51:18 Voltage Offset Correction: v_off_ini = 656.850 uV, v_off_fin = 668.414 uV 18:51:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.463 uVs 18:51:20 I2X Average and RMS of Measurements VT = -88.645 +- 0.570 uVs I2X = 8.155 +- 0.052 uTm^2 18:51:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:51:26 Integrated Voltage Measurement... 18:51:35 Voltage Offset Correction: v_off_ini = 686.748 uV, v_off_fin = 672.762 uV 18:51:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.410 uVs 18:51:35 Integrated Voltage Measurement... 18:51:44 Voltage Offset Correction: v_off_ini = 666.551 uV, v_off_fin = 670.521 uV 18:51:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.610 uVs 18:51:44 Integrated Voltage Measurement... 18:51:53 Voltage Offset Correction: v_off_ini = 673.253 uV, v_off_fin = 672.750 uV 18:51:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.530 uVs 18:51:53 Integrated Voltage Measurement... 18:52:02 Voltage Offset Correction: v_off_ini = 674.146 uV, v_off_fin = 687.918 uV 18:52:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.867 uVs 18:52:02 Integrated Voltage Measurement... 18:52:11 Voltage Offset Correction: v_off_ini = 703.695 uV, v_off_fin = 686.177 uV 18:52:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.259 uVs 18:52:11 Integrated Voltage Measurement... 18:52:20 Voltage Offset Correction: v_off_ini = 692.849 uV, v_off_fin = 685.477 uV 18:52:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.230 uVs 18:52:22 I2Y Average and RMS of Measurements VT = -265.151 +- 5.757 uVs I2Y = -24.394 +- 0.530 uTm^2 18:52:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:52:31 Integrated Voltage Measurement... 18:52:40 Voltage Offset Correction: v_off_ini = 681.793 uV, v_off_fin = 689.236 uV 18:52:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -88.456 uVs 18:52:40 Integrated Voltage Measurement... 18:52:49 Voltage Offset Correction: v_off_ini = 685.821 uV, v_off_fin = 676.470 uV 18:52:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.353 uVs 18:52:49 Integrated Voltage Measurement... 18:52:58 Voltage Offset Correction: v_off_ini = 671.445 uV, v_off_fin = 683.344 uV 18:52:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.137 uVs 18:52:58 Integrated Voltage Measurement... 18:53:07 Voltage Offset Correction: v_off_ini = 690.794 uV, v_off_fin = 701.779 uV 18:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.796 uVs 18:53:07 Integrated Voltage Measurement... 18:53:16 Voltage Offset Correction: v_off_ini = 685.112 uV, v_off_fin = 695.529 uV 18:53:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.488 uVs 18:53:16 Integrated Voltage Measurement... 18:53:25 Voltage Offset Correction: v_off_ini = 691.965 uV, v_off_fin = 685.237 uV 18:53:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.341 uVs 18:53:29 I1X Average and RMS of Measurements VT = -81.428 +- 3.481 uVs I1X = 16.287 +- 0.697 uTm 18:53:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:53:36 Integrated Voltage Measurement... 18:53:45 Voltage Offset Correction: v_off_ini = 705.071 uV, v_off_fin = 683.495 uV 18:53:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -181.185 uVs 18:53:45 Integrated Voltage Measurement... 18:53:54 Voltage Offset Correction: v_off_ini = 702.667 uV, v_off_fin = 725.446 uV 18:53:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.853 uVs 18:53:54 Integrated Voltage Measurement... 18:54:03 Voltage Offset Correction: v_off_ini = 705.367 uV, v_off_fin = 688.180 uV 18:54:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.627 uVs 18:54:03 Integrated Voltage Measurement... 18:54:12 Voltage Offset Correction: v_off_ini = 723.686 uV, v_off_fin = 717.957 uV 18:54:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.483 uVs 18:54:12 Integrated Voltage Measurement... 18:54:21 Voltage Offset Correction: v_off_ini = 708.303 uV, v_off_fin = 699.207 uV 18:54:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -219.910 uVs 18:54:21 Integrated Voltage Measurement... 18:54:30 Voltage Offset Correction: v_off_ini = 709.823 uV, v_off_fin = 731.109 uV 18:54:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 195.615 uVs 18:54:34 I1Y Average and RMS of Measurements VT = -199.779 +- 9.117 uVs I1Y = -39.954 +- 1.821 uTm 18:54:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:54:39 Integrated Voltage Measurement... 18:54:48 Voltage Offset Correction: v_off_ini = 693.998 uV, v_off_fin = 694.996 uV 18:54:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.150 uVs 18:54:48 Integrated Voltage Measurement... 18:54:57 Voltage Offset Correction: v_off_ini = 673.782 uV, v_off_fin = 681.385 uV 18:54:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.731 uVs 18:54:57 Integrated Voltage Measurement... 18:55:06 Voltage Offset Correction: v_off_ini = 687.941 uV, v_off_fin = 684.006 uV 18:55:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.867 uVs 18:55:06 Integrated Voltage Measurement... 18:55:15 Voltage Offset Correction: v_off_ini = 708.623 uV, v_off_fin = 712.317 uV 18:55:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.742 uVs 18:55:15 Integrated Voltage Measurement... 18:55:24 Voltage Offset Correction: v_off_ini = 724.477 uV, v_off_fin = 701.674 uV 18:55:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.242 uVs 18:55:24 Integrated Voltage Measurement... 18:55:33 Voltage Offset Correction: v_off_ini = 688.960 uV, v_off_fin = 711.666 uV 18:55:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.884 uVs 18:55:36 I2X Average and RMS of Measurements VT = -87.436 +- 10.098 uVs I2X = 8.044 +- 0.929 uTm^2 18:55:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:55:41 Integrated Voltage Measurement... 18:55:50 Voltage Offset Correction: v_off_ini = 707.940 uV, v_off_fin = 707.646 uV 18:55:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.501 uVs 18:55:50 Integrated Voltage Measurement... 18:55:59 Voltage Offset Correction: v_off_ini = 697.183 uV, v_off_fin = 690.475 uV 18:55:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.012 uVs 18:55:59 Integrated Voltage Measurement... 18:56:08 Voltage Offset Correction: v_off_ini = 693.312 uV, v_off_fin = 689.846 uV 18:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.745 uVs 18:56:08 Integrated Voltage Measurement... 18:56:17 Voltage Offset Correction: v_off_ini = 692.181 uV, v_off_fin = 689.684 uV 18:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.162 uVs 18:56:17 Integrated Voltage Measurement... 18:56:26 Voltage Offset Correction: v_off_ini = 702.613 uV, v_off_fin = 716.747 uV 18:56:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.251 uVs 18:56:26 Integrated Voltage Measurement... 18:56:35 Voltage Offset Correction: v_off_ini = 694.219 uV, v_off_fin = 699.719 uV 18:56:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.542 uVs 18:56:37 I2Y Average and RMS of Measurements VT = -256.036 +- 4.745 uVs I2Y = -23.555 +- 0.437 uTm^2 18:57:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:57:12 Integrated Voltage Measurement... 18:57:21 Voltage Offset Correction: v_off_ini = 685.344 uV, v_off_fin = 677.073 uV 18:57:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.396 uVs 18:57:21 Integrated Voltage Measurement... 18:57:30 Voltage Offset Correction: v_off_ini = 688.975 uV, v_off_fin = 679.226 uV 18:57:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.757 uVs 18:57:30 Integrated Voltage Measurement... 18:57:39 Voltage Offset Correction: v_off_ini = 671.817 uV, v_off_fin = 687.721 uV 18:57:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.883 uVs 18:57:39 Integrated Voltage Measurement... 18:57:48 Voltage Offset Correction: v_off_ini = 698.937 uV, v_off_fin = 678.848 uV 18:57:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.755 uVs 18:57:48 Integrated Voltage Measurement... 18:57:57 Voltage Offset Correction: v_off_ini = 676.674 uV, v_off_fin = 676.104 uV 18:57:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.220 uVs 18:57:57 Integrated Voltage Measurement... 18:58:06 Voltage Offset Correction: v_off_ini = 698.121 uV, v_off_fin = 688.074 uV 18:58:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.052 uVs 18:58:10 I1X Average and RMS of Measurements VT = -97.177 +- 6.014 uVs I1X = 19.436 +- 1.203 uTm 18:58:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:58:17 Integrated Voltage Measurement... 18:58:26 Voltage Offset Correction: v_off_ini = 687.516 uV, v_off_fin = 677.600 uV 18:58:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.513 uVs 18:58:26 Integrated Voltage Measurement... 18:58:35 Voltage Offset Correction: v_off_ini = 687.723 uV, v_off_fin = 687.232 uV 18:58:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.191 uVs 18:58:35 Integrated Voltage Measurement... 18:58:44 Voltage Offset Correction: v_off_ini = 681.845 uV, v_off_fin = 683.943 uV 18:58:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.461 uVs 18:58:44 Integrated Voltage Measurement... 18:58:53 Voltage Offset Correction: v_off_ini = 693.095 uV, v_off_fin = 695.752 uV 18:58:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.332 uVs 18:58:53 Integrated Voltage Measurement... 18:59:02 Voltage Offset Correction: v_off_ini = 687.462 uV, v_off_fin = 693.776 uV 18:59:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.969 uVs 18:59:02 Integrated Voltage Measurement... 18:59:11 Voltage Offset Correction: v_off_ini = 719.255 uV, v_off_fin = 731.025 uV 18:59:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.225 uVs 18:59:15 I1Y Average and RMS of Measurements VT = -225.615 +- 7.353 uVs I1Y = -45.123 +- 1.471 uTm 18:59:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:59:23 Integrated Voltage Measurement... 18:59:32 Voltage Offset Correction: v_off_ini = 697.054 uV, v_off_fin = 696.533 uV 18:59:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.291 uVs 18:59:32 Integrated Voltage Measurement... 18:59:41 Voltage Offset Correction: v_off_ini = 695.249 uV, v_off_fin = 690.594 uV 18:59:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.650 uVs 18:59:41 Integrated Voltage Measurement... 18:59:50 Voltage Offset Correction: v_off_ini = 678.245 uV, v_off_fin = 682.055 uV 18:59:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.699 uVs 18:59:50 Integrated Voltage Measurement... 18:59:59 Voltage Offset Correction: v_off_ini = 685.694 uV, v_off_fin = 691.982 uV 18:59:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.855 uVs 18:59:59 Integrated Voltage Measurement... 19:00:08 Voltage Offset Correction: v_off_ini = 687.594 uV, v_off_fin = 692.135 uV 19:00:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.232 uVs 19:00:08 Integrated Voltage Measurement... 19:00:17 Voltage Offset Correction: v_off_ini = 715.161 uV, v_off_fin = 717.806 uV 19:00:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.821 uVs 19:00:20 I2X Average and RMS of Measurements VT = -99.258 +- 15.177 uVs I2X = 9.132 +- 1.396 uTm^2 19:00:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:00:28 Integrated Voltage Measurement... 19:00:37 Voltage Offset Correction: v_off_ini = 706.968 uV, v_off_fin = 683.744 uV 19:00:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.681 uVs 19:00:37 Integrated Voltage Measurement... 19:00:46 Voltage Offset Correction: v_off_ini = 698.978 uV, v_off_fin = 698.879 uV 19:00:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.496 uVs 19:00:46 Integrated Voltage Measurement... 19:00:55 Voltage Offset Correction: v_off_ini = 701.688 uV, v_off_fin = 691.413 uV 19:00:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.310 uVs 19:00:55 Integrated Voltage Measurement... 19:01:04 Voltage Offset Correction: v_off_ini = 691.846 uV, v_off_fin = 699.239 uV 19:01:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.417 uVs 19:01:04 Integrated Voltage Measurement... 19:01:13 Voltage Offset Correction: v_off_ini = 690.243 uV, v_off_fin = 700.199 uV 19:01:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.027 uVs 19:01:13 Integrated Voltage Measurement... 19:01:22 Voltage Offset Correction: v_off_ini = 712.579 uV, v_off_fin = 692.954 uV 19:01:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.310 uVs 19:01:24 I2Y Average and RMS of Measurements VT = -254.373 +- 3.882 uVs I2Y = -23.402 +- 0.357 uTm^2 19:01:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:01:33 Integrated Voltage Measurement... 19:01:42 Voltage Offset Correction: v_off_ini = 696.109 uV, v_off_fin = 692.813 uV 19:01:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.406 uVs 19:01:42 Integrated Voltage Measurement... 19:01:51 Voltage Offset Correction: v_off_ini = 706.812 uV, v_off_fin = 703.422 uV 19:01:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.951 uVs 19:01:51 Integrated Voltage Measurement... 19:02:00 Voltage Offset Correction: v_off_ini = 717.048 uV, v_off_fin = 718.360 uV 19:02:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.162 uVs 19:02:00 Integrated Voltage Measurement... 19:02:09 Voltage Offset Correction: v_off_ini = 707.704 uV, v_off_fin = 717.702 uV 19:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.021 uVs 19:02:09 Integrated Voltage Measurement... 19:02:18 Voltage Offset Correction: v_off_ini = 716.047 uV, v_off_fin = 710.738 uV 19:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.371 uVs 19:02:18 Integrated Voltage Measurement... 19:02:27 Voltage Offset Correction: v_off_ini = 719.572 uV, v_off_fin = 705.244 uV 19:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.692 uVs 19:02:31 I1X Average and RMS of Measurements VT = -89.934 +- 7.917 uVs I1X = 17.987 +- 1.583 uTm 19:02:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:02:38 Integrated Voltage Measurement... 19:02:47 Voltage Offset Correction: v_off_ini = 700.090 uV, v_off_fin = 680.593 uV 19:02:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.878 uVs 19:02:47 Integrated Voltage Measurement... 19:02:56 Voltage Offset Correction: v_off_ini = 687.662 uV, v_off_fin = 704.767 uV 19:02:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.203 uVs 19:02:56 Integrated Voltage Measurement... 19:03:05 Voltage Offset Correction: v_off_ini = 698.024 uV, v_off_fin = 692.591 uV 19:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.939 uVs 19:03:05 Integrated Voltage Measurement... 19:03:14 Voltage Offset Correction: v_off_ini = 705.618 uV, v_off_fin = 711.229 uV 19:03:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.661 uVs 19:03:14 Integrated Voltage Measurement... 19:03:23 Voltage Offset Correction: v_off_ini = 690.039 uV, v_off_fin = 679.106 uV 19:03:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.222 uVs 19:03:23 Integrated Voltage Measurement... 19:03:32 Voltage Offset Correction: v_off_ini = 693.138 uV, v_off_fin = 695.571 uV 19:03:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.044 uVs 19:03:37 I1Y Average and RMS of Measurements VT = -214.658 +- 6.214 uVs I1Y = -42.932 +- 1.243 uTm 19:03:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:03:44 Integrated Voltage Measurement... 19:03:53 Voltage Offset Correction: v_off_ini = 686.461 uV, v_off_fin = 687.130 uV 19:03:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.974 uVs 19:03:53 Integrated Voltage Measurement... 19:04:02 Voltage Offset Correction: v_off_ini = 688.603 uV, v_off_fin = 698.275 uV 19:04:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.466 uVs 19:04:02 Integrated Voltage Measurement... 19:04:11 Voltage Offset Correction: v_off_ini = 703.928 uV, v_off_fin = 689.685 uV 19:04:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.845 uVs 19:04:11 Integrated Voltage Measurement... 19:04:20 Voltage Offset Correction: v_off_ini = 687.323 uV, v_off_fin = 705.433 uV 19:04:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.183 uVs 19:04:20 Integrated Voltage Measurement... 19:04:29 Voltage Offset Correction: v_off_ini = 712.296 uV, v_off_fin = 707.124 uV 19:04:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.174 uVs 19:04:30 Integrated Voltage Measurement... 19:04:38 Voltage Offset Correction: v_off_ini = 713.004 uV, v_off_fin = 720.992 uV 19:04:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.819 uVs 19:04:41 I2X Average and RMS of Measurements VT = -99.743 +- 9.952 uVs I2X = 9.176 +- 0.916 uTm^2 19:04:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:04:49 Integrated Voltage Measurement... 19:04:58 Voltage Offset Correction: v_off_ini = 715.297 uV, v_off_fin = 721.432 uV 19:04:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.108 uVs 19:04:58 Integrated Voltage Measurement... 19:05:07 Voltage Offset Correction: v_off_ini = 701.356 uV, v_off_fin = 704.431 uV 19:05:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.229 uVs 19:05:07 Integrated Voltage Measurement... 19:05:16 Voltage Offset Correction: v_off_ini = 705.649 uV, v_off_fin = 702.716 uV 19:05:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.281 uVs 19:05:16 Integrated Voltage Measurement... 19:05:25 Voltage Offset Correction: v_off_ini = 717.683 uV, v_off_fin = 724.549 uV 19:05:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.937 uVs 19:05:25 Integrated Voltage Measurement... 19:05:34 Voltage Offset Correction: v_off_ini = 697.639 uV, v_off_fin = 699.099 uV 19:05:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.033 uVs 19:05:34 Integrated Voltage Measurement... 19:05:43 Voltage Offset Correction: v_off_ini = 716.058 uV, v_off_fin = 712.510 uV 19:05:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.925 uVs 19:05:45 I2Y Average and RMS of Measurements VT = -266.252 +- 9.157 uVs I2Y = -24.495 +- 0.842 uTm^2 19:05:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:05:54 Integrated Voltage Measurement... 19:06:03 Voltage Offset Correction: v_off_ini = 719.342 uV, v_off_fin = 706.985 uV 19:06:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.822 uVs 19:06:03 Integrated Voltage Measurement... 19:06:12 Voltage Offset Correction: v_off_ini = 706.061 uV, v_off_fin = 695.441 uV 19:06:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.491 uVs 19:06:12 Integrated Voltage Measurement... 19:06:21 Voltage Offset Correction: v_off_ini = 690.485 uV, v_off_fin = 688.320 uV 19:06:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.293 uVs 19:06:21 Integrated Voltage Measurement... 19:06:30 Voltage Offset Correction: v_off_ini = 677.756 uV, v_off_fin = 687.558 uV 19:06:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.967 uVs 19:06:30 Integrated Voltage Measurement... 19:06:39 Voltage Offset Correction: v_off_ini = 696.676 uV, v_off_fin = 691.428 uV 19:06:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.801 uVs 19:06:39 Integrated Voltage Measurement... 19:06:48 Voltage Offset Correction: v_off_ini = 690.730 uV, v_off_fin = 681.230 uV 19:06:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.736 uVs 19:06:53 I1X Average and RMS of Measurements VT = -90.519 +- 12.421 uVs I1X = 18.104 +- 2.484 uTm 19:06:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:06:59 Integrated Voltage Measurement... 19:07:08 Voltage Offset Correction: v_off_ini = 684.196 uV, v_off_fin = 679.223 uV 19:07:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -235.704 uVs 19:07:08 Integrated Voltage Measurement... 19:07:17 Voltage Offset Correction: v_off_ini = 691.318 uV, v_off_fin = 695.298 uV 19:07:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.751 uVs 19:07:17 Integrated Voltage Measurement... 19:07:26 Voltage Offset Correction: v_off_ini = 666.028 uV, v_off_fin = 667.260 uV 19:07:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.870 uVs 19:07:26 Integrated Voltage Measurement... 19:07:35 Voltage Offset Correction: v_off_ini = 682.308 uV, v_off_fin = 691.952 uV 19:07:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.024 uVs 19:07:35 Integrated Voltage Measurement... 19:07:44 Voltage Offset Correction: v_off_ini = 689.037 uV, v_off_fin = 682.336 uV 19:07:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.558 uVs 19:07:44 Integrated Voltage Measurement... 19:07:53 Voltage Offset Correction: v_off_ini = 672.596 uV, v_off_fin = 680.180 uV 19:07:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.091 uVs 19:07:58 I1Y Average and RMS of Measurements VT = -218.500 +- 2.550 uVs I1Y = -43.701 +- 0.509 uTm 19:08:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:08:05 Integrated Voltage Measurement... 19:08:14 Voltage Offset Correction: v_off_ini = 675.967 uV, v_off_fin = 682.669 uV 19:08:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -104.184 uVs 19:08:14 Integrated Voltage Measurement... 19:08:23 Voltage Offset Correction: v_off_ini = 688.672 uV, v_off_fin = 690.348 uV 19:08:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.404 uVs 19:08:23 Integrated Voltage Measurement... 19:08:32 Voltage Offset Correction: v_off_ini = 688.747 uV, v_off_fin = 677.030 uV 19:08:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.887 uVs 19:08:33 Integrated Voltage Measurement... 19:08:41 Voltage Offset Correction: v_off_ini = 669.276 uV, v_off_fin = 669.179 uV 19:08:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.314 uVs 19:08:42 Integrated Voltage Measurement... 19:08:51 Voltage Offset Correction: v_off_ini = 654.991 uV, v_off_fin = 669.100 uV 19:08:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.501 uVs 19:08:51 Integrated Voltage Measurement... 19:09:00 Voltage Offset Correction: v_off_ini = 693.939 uV, v_off_fin = 685.955 uV 19:09:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.104 uVs 19:09:02 I2X Average and RMS of Measurements VT = -94.399 +- 10.725 uVs I2X = 8.685 +- 0.986 uTm^2 19:09:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:09:10 Integrated Voltage Measurement... 19:09:19 Voltage Offset Correction: v_off_ini = 677.898 uV, v_off_fin = 681.815 uV 19:09:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.615 uVs 19:09:19 Integrated Voltage Measurement... 19:09:28 Voltage Offset Correction: v_off_ini = 682.088 uV, v_off_fin = 682.634 uV 19:09:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.207 uVs 19:09:28 Integrated Voltage Measurement... 19:09:37 Voltage Offset Correction: v_off_ini = 684.403 uV, v_off_fin = 685.542 uV 19:09:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.562 uVs 19:09:37 Integrated Voltage Measurement... 19:09:46 Voltage Offset Correction: v_off_ini = 699.953 uV, v_off_fin = 709.366 uV 19:09:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.353 uVs 19:09:46 Integrated Voltage Measurement... 19:09:55 Voltage Offset Correction: v_off_ini = 700.609 uV, v_off_fin = 707.677 uV 19:09:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.522 uVs 19:09:55 Integrated Voltage Measurement... 19:10:04 Voltage Offset Correction: v_off_ini = 721.053 uV, v_off_fin = 700.186 uV 19:10:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.286 uVs 19:10:06 I2Y Average and RMS of Measurements VT = -254.758 +- 5.338 uVs I2Y = -23.438 +- 0.491 uTm^2 19:10:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:10:15 Integrated Voltage Measurement... 19:10:24 Voltage Offset Correction: v_off_ini = 690.248 uV, v_off_fin = 682.004 uV 19:10:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.195 uVs 19:10:24 Integrated Voltage Measurement... 19:10:33 Voltage Offset Correction: v_off_ini = 687.235 uV, v_off_fin = 696.831 uV 19:10:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.404 uVs 19:10:33 Integrated Voltage Measurement... 19:10:42 Voltage Offset Correction: v_off_ini = 706.937 uV, v_off_fin = 697.749 uV 19:10:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.322 uVs 19:10:42 Integrated Voltage Measurement... 19:10:51 Voltage Offset Correction: v_off_ini = 703.372 uV, v_off_fin = 710.898 uV 19:10:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.461 uVs 19:10:51 Integrated Voltage Measurement... 19:11:00 Voltage Offset Correction: v_off_ini = 704.276 uV, v_off_fin = 687.149 uV 19:11:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.031 uVs 19:11:00 Integrated Voltage Measurement... 19:11:09 Voltage Offset Correction: v_off_ini = 705.144 uV, v_off_fin = 708.167 uV 19:11:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.033 uVs 19:11:14 I1X Average and RMS of Measurements VT = -84.074 +- 3.408 uVs I1X = 16.815 +- 0.682 uTm 19:11:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:11:20 Integrated Voltage Measurement... 19:11:29 Voltage Offset Correction: v_off_ini = 712.599 uV, v_off_fin = 702.955 uV 19:11:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.478 uVs 19:11:29 Integrated Voltage Measurement... 19:11:38 Voltage Offset Correction: v_off_ini = 705.929 uV, v_off_fin = 706.485 uV 19:11:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.350 uVs 19:11:39 Integrated Voltage Measurement... 19:11:47 Voltage Offset Correction: v_off_ini = 700.896 uV, v_off_fin = 701.044 uV 19:11:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.652 uVs 19:11:48 Integrated Voltage Measurement... 19:11:56 Voltage Offset Correction: v_off_ini = 685.248 uV, v_off_fin = 703.707 uV 19:11:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.426 uVs 19:11:57 Integrated Voltage Measurement... 19:12:05 Voltage Offset Correction: v_off_ini = 682.421 uV, v_off_fin = 692.300 uV 19:12:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.419 uVs 19:12:06 Integrated Voltage Measurement... 19:12:14 Voltage Offset Correction: v_off_ini = 697.124 uV, v_off_fin = 717.212 uV 19:12:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.515 uVs 19:12:19 I1Y Average and RMS of Measurements VT = -217.473 +- 2.528 uVs I1Y = -43.495 +- 0.506 uTm 19:12:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:12:26 Integrated Voltage Measurement... 19:12:35 Voltage Offset Correction: v_off_ini = 684.190 uV, v_off_fin = 671.726 uV 19:12:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.486 uVs 19:12:36 Integrated Voltage Measurement... 19:12:44 Voltage Offset Correction: v_off_ini = 672.612 uV, v_off_fin = 682.447 uV 19:12:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.467 uVs 19:12:45 Integrated Voltage Measurement... 19:12:54 Voltage Offset Correction: v_off_ini = 697.434 uV, v_off_fin = 706.209 uV 19:12:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.374 uVs 19:12:54 Integrated Voltage Measurement... 19:13:03 Voltage Offset Correction: v_off_ini = 712.725 uV, v_off_fin = 698.786 uV 19:13:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.136 uVs 19:13:03 Integrated Voltage Measurement... 19:13:12 Voltage Offset Correction: v_off_ini = 685.347 uV, v_off_fin = 667.228 uV 19:13:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.207 uVs 19:13:12 Integrated Voltage Measurement... 19:13:21 Voltage Offset Correction: v_off_ini = 682.871 uV, v_off_fin = 674.215 uV 19:13:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.125 uVs 19:13:23 I2X Average and RMS of Measurements VT = -101.799 +- 9.127 uVs I2X = 9.366 +- 0.840 uTm^2 19:13:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:13:31 Integrated Voltage Measurement... 19:13:40 Voltage Offset Correction: v_off_ini = 679.435 uV, v_off_fin = 688.375 uV 19:13:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.957 uVs 19:13:40 Integrated Voltage Measurement... 19:13:49 Voltage Offset Correction: v_off_ini = 678.454 uV, v_off_fin = 669.707 uV 19:13:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.838 uVs 19:13:49 Integrated Voltage Measurement... 19:13:58 Voltage Offset Correction: v_off_ini = 658.008 uV, v_off_fin = 668.593 uV 19:13:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.374 uVs 19:13:58 Integrated Voltage Measurement... 19:14:07 Voltage Offset Correction: v_off_ini = 682.515 uV, v_off_fin = 682.034 uV 19:14:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.157 uVs 19:14:07 Integrated Voltage Measurement... 19:14:16 Voltage Offset Correction: v_off_ini = 690.962 uV, v_off_fin = 675.896 uV 19:14:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.376 uVs 19:14:16 Integrated Voltage Measurement... 19:14:25 Voltage Offset Correction: v_off_ini = 664.809 uV, v_off_fin = 667.807 uV 19:14:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.651 uVs 19:14:27 I2Y Average and RMS of Measurements VT = -252.725 +- 13.883 uVs I2Y = -23.251 +- 1.277 uTm^2 19:14:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:14:36 Integrated Voltage Measurement... 19:14:45 Voltage Offset Correction: v_off_ini = 679.555 uV, v_off_fin = 666.311 uV 19:14:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.418 uVs 19:14:45 Integrated Voltage Measurement... 19:14:54 Voltage Offset Correction: v_off_ini = 684.166 uV, v_off_fin = 710.726 uV 19:14:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.185 uVs 19:14:54 Integrated Voltage Measurement... 19:15:03 Voltage Offset Correction: v_off_ini = 712.118 uV, v_off_fin = 693.662 uV 19:15:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.035 uVs 19:15:04 Integrated Voltage Measurement... 19:15:12 Voltage Offset Correction: v_off_ini = 700.297 uV, v_off_fin = 697.154 uV 19:15:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.157 uVs 19:15:13 Integrated Voltage Measurement... 19:15:22 Voltage Offset Correction: v_off_ini = 693.180 uV, v_off_fin = 692.885 uV 19:15:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.134 uVs 19:15:22 Integrated Voltage Measurement... 19:15:31 Voltage Offset Correction: v_off_ini = 693.803 uV, v_off_fin = 684.887 uV 19:15:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.919 uVs 19:15:35 I1X Average and RMS of Measurements VT = -83.308 +- 4.126 uVs I1X = 16.662 +- 0.825 uTm 19:15:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:15:42 Integrated Voltage Measurement... 19:15:51 Voltage Offset Correction: v_off_ini = 701.162 uV, v_off_fin = 684.086 uV 19:15:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.376 uVs 19:15:51 Integrated Voltage Measurement... 19:16:00 Voltage Offset Correction: v_off_ini = 684.060 uV, v_off_fin = 691.879 uV 19:16:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.125 uVs 19:16:00 Integrated Voltage Measurement... 19:16:09 Voltage Offset Correction: v_off_ini = 693.151 uV, v_off_fin = 682.577 uV 19:16:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.943 uVs 19:16:09 Integrated Voltage Measurement... 19:16:18 Voltage Offset Correction: v_off_ini = 713.038 uV, v_off_fin = 723.247 uV 19:16:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.496 uVs 19:16:18 Integrated Voltage Measurement... 19:16:27 Voltage Offset Correction: v_off_ini = 703.128 uV, v_off_fin = 688.062 uV 19:16:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.990 uVs 19:16:27 Integrated Voltage Measurement... 19:16:36 Voltage Offset Correction: v_off_ini = 706.851 uV, v_off_fin = 704.990 uV 19:16:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.636 uVs 19:16:40 I1Y Average and RMS of Measurements VT = -219.928 +- 3.539 uVs I1Y = -43.986 +- 0.708 uTm 19:16:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:16:48 Integrated Voltage Measurement... 19:16:57 Voltage Offset Correction: v_off_ini = 665.090 uV, v_off_fin = 655.289 uV 19:16:57 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.301 uVs 19:16:57 Integrated Voltage Measurement... 19:17:06 Voltage Offset Correction: v_off_ini = 676.456 uV, v_off_fin = 688.471 uV 19:17:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.505 uVs 19:17:06 Integrated Voltage Measurement... 19:17:15 Voltage Offset Correction: v_off_ini = 678.855 uV, v_off_fin = 662.558 uV 19:17:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.975 uVs 19:17:15 Integrated Voltage Measurement... 19:17:24 Voltage Offset Correction: v_off_ini = 669.826 uV, v_off_fin = 658.690 uV 19:17:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.592 uVs 19:17:24 Integrated Voltage Measurement... 19:17:33 Voltage Offset Correction: v_off_ini = 666.582 uV, v_off_fin = 657.063 uV 19:17:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.453 uVs 19:17:33 Integrated Voltage Measurement... 19:17:42 Voltage Offset Correction: v_off_ini = 661.216 uV, v_off_fin = 682.759 uV 19:17:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.017 uVs 19:17:44 I2X Average and RMS of Measurements VT = -94.807 +- 1.615 uVs I2X = 8.722 +- 0.149 uTm^2 19:17:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:17:52 Integrated Voltage Measurement... 19:18:01 Voltage Offset Correction: v_off_ini = 676.324 uV, v_off_fin = 689.274 uV 19:18:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.700 uVs 19:18:01 Integrated Voltage Measurement... 19:18:10 Voltage Offset Correction: v_off_ini = 662.469 uV, v_off_fin = 673.911 uV 19:18:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.465 uVs 19:18:10 Integrated Voltage Measurement... 19:18:19 Voltage Offset Correction: v_off_ini = 668.526 uV, v_off_fin = 649.615 uV 19:18:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.469 uVs 19:18:19 Integrated Voltage Measurement... 19:18:28 Voltage Offset Correction: v_off_ini = 656.579 uV, v_off_fin = 656.832 uV 19:18:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.648 uVs 19:18:28 Integrated Voltage Measurement... 19:18:37 Voltage Offset Correction: v_off_ini = 648.688 uV, v_off_fin = 677.929 uV 19:18:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.201 uVs 19:18:37 Integrated Voltage Measurement... 19:18:46 Voltage Offset Correction: v_off_ini = 681.738 uV, v_off_fin = 675.719 uV 19:18:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.634 uVs 19:18:49 I2Y Average and RMS of Measurements VT = -254.186 +- 3.399 uVs I2Y = -23.385 +- 0.313 uTm^2 19:18:56 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:19:01 Integrated Voltage Measurement... 19:19:10 Voltage Offset Correction: v_off_ini = 657.508 uV, v_off_fin = 666.982 uV 19:19:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -99.131 uVs 19:19:10 Integrated Voltage Measurement... 19:19:19 Voltage Offset Correction: v_off_ini = 669.977 uV, v_off_fin = 655.764 uV 19:19:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.654 uVs 19:19:19 Integrated Voltage Measurement... 19:19:28 Voltage Offset Correction: v_off_ini = 649.874 uV, v_off_fin = 652.362 uV 19:19:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.002 uVs 19:19:28 Integrated Voltage Measurement... 19:19:37 Voltage Offset Correction: v_off_ini = 660.762 uV, v_off_fin = 660.055 uV 19:19:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.389 uVs 19:19:37 Integrated Voltage Measurement... 19:19:46 Voltage Offset Correction: v_off_ini = 672.305 uV, v_off_fin = 669.813 uV 19:19:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.114 uVs 19:19:46 Integrated Voltage Measurement... 19:19:55 Voltage Offset Correction: v_off_ini = 653.519 uV, v_off_fin = 649.692 uV 19:19:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.213 uVs 19:19:59 I1X Average and RMS of Measurements VT = -103.750 +- 9.214 uVs I1X = 20.750 +- 1.843 uTm 19:20:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:20:06 Integrated Voltage Measurement... 19:20:15 Voltage Offset Correction: v_off_ini = 657.587 uV, v_off_fin = 658.551 uV 19:20:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.415 uVs 19:20:15 Integrated Voltage Measurement... 19:20:24 Voltage Offset Correction: v_off_ini = 662.113 uV, v_off_fin = 671.096 uV 19:20:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.894 uVs 19:20:24 Integrated Voltage Measurement... 19:20:33 Voltage Offset Correction: v_off_ini = 671.527 uV, v_off_fin = 653.158 uV 19:20:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.636 uVs 19:20:33 Integrated Voltage Measurement... 19:20:42 Voltage Offset Correction: v_off_ini = 655.395 uV, v_off_fin = 671.239 uV 19:20:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.530 uVs 19:20:42 Integrated Voltage Measurement... 19:20:51 Voltage Offset Correction: v_off_ini = 686.576 uV, v_off_fin = 674.060 uV 19:20:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.243 uVs 19:20:51 Integrated Voltage Measurement... 19:21:00 Voltage Offset Correction: v_off_ini = 670.800 uV, v_off_fin = 688.598 uV 19:21:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.483 uVs 19:21:04 I1Y Average and RMS of Measurements VT = -217.534 +- 5.941 uVs I1Y = -43.507 +- 1.188 uTm 19:21:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:21:09 Integrated Voltage Measurement... 19:21:18 Voltage Offset Correction: v_off_ini = 677.138 uV, v_off_fin = 654.001 uV 19:21:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.038 uVs 19:21:18 Integrated Voltage Measurement... 19:21:27 Voltage Offset Correction: v_off_ini = 657.197 uV, v_off_fin = 655.031 uV 19:21:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.340 uVs 19:21:27 Integrated Voltage Measurement... 19:21:36 Voltage Offset Correction: v_off_ini = 675.896 uV, v_off_fin = 674.036 uV 19:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.478 uVs 19:21:36 Integrated Voltage Measurement... 19:21:45 Voltage Offset Correction: v_off_ini = 684.781 uV, v_off_fin = 680.796 uV 19:21:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.552 uVs 19:21:45 Integrated Voltage Measurement... 19:21:54 Voltage Offset Correction: v_off_ini = 678.769 uV, v_off_fin = 676.583 uV 19:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.602 uVs 19:21:54 Integrated Voltage Measurement... 19:22:03 Voltage Offset Correction: v_off_ini = 656.232 uV, v_off_fin = 665.147 uV 19:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.587 uVs 19:22:06 I2X Average and RMS of Measurements VT = -107.766 +- 5.159 uVs I2X = 9.914 +- 0.475 uTm^2 19:22:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:22:11 Integrated Voltage Measurement... 19:22:20 Voltage Offset Correction: v_off_ini = 672.912 uV, v_off_fin = 683.320 uV 19:22:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.974 uVs 19:22:20 Integrated Voltage Measurement... 19:22:29 Voltage Offset Correction: v_off_ini = 685.629 uV, v_off_fin = 685.602 uV 19:22:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.833 uVs 19:22:29 Integrated Voltage Measurement... 19:22:38 Voltage Offset Correction: v_off_ini = 701.622 uV, v_off_fin = 689.973 uV 19:22:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.316 uVs 19:22:38 Integrated Voltage Measurement... 19:22:47 Voltage Offset Correction: v_off_ini = 686.187 uV, v_off_fin = 694.390 uV 19:22:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.403 uVs 19:22:47 Integrated Voltage Measurement... 19:22:56 Voltage Offset Correction: v_off_ini = 691.102 uV, v_off_fin = 697.058 uV 19:22:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.883 uVs 19:22:56 Integrated Voltage Measurement... 19:23:05 Voltage Offset Correction: v_off_ini = 702.792 uV, v_off_fin = 716.248 uV 19:23:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.124 uVs 19:23:08 I2Y Average and RMS of Measurements VT = -256.089 +- 7.978 uVs I2Y = -23.560 +- 0.734 uTm^2 19:23:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:23:16 Integrated Voltage Measurement... 19:23:25 Voltage Offset Correction: v_off_ini = 676.957 uV, v_off_fin = 672.443 uV 19:23:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -91.767 uVs 19:23:25 Integrated Voltage Measurement... 19:23:34 Voltage Offset Correction: v_off_ini = 673.839 uV, v_off_fin = 667.389 uV 19:23:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.114 uVs 19:23:34 Integrated Voltage Measurement... 19:23:43 Voltage Offset Correction: v_off_ini = 679.777 uV, v_off_fin = 677.538 uV 19:23:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.748 uVs 19:23:43 Integrated Voltage Measurement... 19:23:52 Voltage Offset Correction: v_off_ini = 687.329 uV, v_off_fin = 686.759 uV 19:23:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.928 uVs 19:23:52 Integrated Voltage Measurement... 19:24:01 Voltage Offset Correction: v_off_ini = 679.975 uV, v_off_fin = 683.117 uV 19:24:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.681 uVs 19:24:01 Integrated Voltage Measurement... 19:24:10 Voltage Offset Correction: v_off_ini = 684.296 uV, v_off_fin = 694.858 uV 19:24:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.584 uVs 19:24:14 I1X Average and RMS of Measurements VT = -83.970 +- 1.753 uVs I1X = 16.795 +- 0.351 uTm 19:24:17 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:24:21 Integrated Voltage Measurement... 19:24:30 Voltage Offset Correction: v_off_ini = 686.589 uV, v_off_fin = 692.885 uV 19:24:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.776 uVs 19:24:30 Integrated Voltage Measurement... 19:24:39 Voltage Offset Correction: v_off_ini = 687.940 uV, v_off_fin = 709.729 uV 19:24:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.458 uVs 19:24:39 Integrated Voltage Measurement... 19:24:48 Voltage Offset Correction: v_off_ini = 680.045 uV, v_off_fin = 671.339 uV 19:24:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.304 uVs 19:24:48 Integrated Voltage Measurement... 19:24:57 Voltage Offset Correction: v_off_ini = 687.237 uV, v_off_fin = 709.662 uV 19:24:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.921 uVs 19:24:57 Integrated Voltage Measurement... 19:25:06 Voltage Offset Correction: v_off_ini = 715.628 uV, v_off_fin = 686.354 uV 19:25:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.020 uVs 19:25:06 Integrated Voltage Measurement... 19:25:15 Voltage Offset Correction: v_off_ini = 692.836 uV, v_off_fin = 668.478 uV 19:25:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.855 uVs 19:25:19 I1Y Average and RMS of Measurements VT = -221.722 +- 12.227 uVs I1Y = -44.344 +- 2.445 uTm 19:25:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:25:24 Integrated Voltage Measurement... 19:25:33 Voltage Offset Correction: v_off_ini = 678.890 uV, v_off_fin = 675.765 uV 19:25:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.156 uVs 19:25:33 Integrated Voltage Measurement... 19:25:42 Voltage Offset Correction: v_off_ini = 666.402 uV, v_off_fin = 675.565 uV 19:25:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.626 uVs 19:25:42 Integrated Voltage Measurement... 19:25:51 Voltage Offset Correction: v_off_ini = 673.000 uV, v_off_fin = 622.245 uV 19:25:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.532 uVs 19:25:52 Integrated Voltage Measurement... 19:26:00 Voltage Offset Correction: v_off_ini = 628.179 uV, v_off_fin = 653.883 uV 19:26:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.653 uVs 19:26:01 Integrated Voltage Measurement... 19:26:10 Voltage Offset Correction: v_off_ini = 648.574 uV, v_off_fin = 655.075 uV 19:26:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.189 uVs 19:26:10 Integrated Voltage Measurement... 19:26:19 Voltage Offset Correction: v_off_ini = 673.574 uV, v_off_fin = 676.678 uV 19:26:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.779 uVs 19:26:21 I2X Average and RMS of Measurements VT = -103.822 +- 1.109 uVs I2X = 9.552 +- 0.102 uTm^2 19:26:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:26:26 Integrated Voltage Measurement... 19:26:35 Voltage Offset Correction: v_off_ini = 647.804 uV, v_off_fin = 643.050 uV 19:26:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.776 uVs 19:26:35 Integrated Voltage Measurement... 19:26:44 Voltage Offset Correction: v_off_ini = 638.285 uV, v_off_fin = 635.418 uV 19:26:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.206 uVs 19:26:44 Integrated Voltage Measurement... 19:26:53 Voltage Offset Correction: v_off_ini = 633.436 uV, v_off_fin = 643.831 uV 19:26:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.833 uVs 19:26:53 Integrated Voltage Measurement... 19:27:02 Voltage Offset Correction: v_off_ini = 640.871 uV, v_off_fin = 639.783 uV 19:27:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 248.231 uVs 19:27:02 Integrated Voltage Measurement... 19:27:11 Voltage Offset Correction: v_off_ini = 649.295 uV, v_off_fin = 651.912 uV 19:27:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.091 uVs 19:27:11 Integrated Voltage Measurement... 19:27:20 Voltage Offset Correction: v_off_ini = 626.866 uV, v_off_fin = 622.606 uV 19:27:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.732 uVs 19:27:23 I2Y Average and RMS of Measurements VT = -241.145 +- 6.119 uVs I2Y = -22.186 +- 0.563 uTm^2 19:27:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:27:31 Integrated Voltage Measurement... 19:27:40 Voltage Offset Correction: v_off_ini = 643.852 uV, v_off_fin = 632.059 uV 19:27:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -98.845 uVs 19:27:40 Integrated Voltage Measurement... 19:27:49 Voltage Offset Correction: v_off_ini = 639.612 uV, v_off_fin = 618.008 uV 19:27:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.986 uVs 19:27:49 Integrated Voltage Measurement... 19:27:58 Voltage Offset Correction: v_off_ini = 614.259 uV, v_off_fin = 593.702 uV 19:27:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.325 uVs 19:27:58 Integrated Voltage Measurement... 19:28:07 Voltage Offset Correction: v_off_ini = 628.473 uV, v_off_fin = 622.883 uV 19:28:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.023 uVs 19:28:07 Integrated Voltage Measurement... 19:28:16 Voltage Offset Correction: v_off_ini = 612.039 uV, v_off_fin = 615.195 uV 19:28:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.075 uVs 19:28:16 Integrated Voltage Measurement... 19:28:25 Voltage Offset Correction: v_off_ini = 599.853 uV, v_off_fin = 612.508 uV 19:28:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 83.185 uVs 19:28:30 I1X Average and RMS of Measurements VT = -88.240 +- 1.751 uVs I1X = 17.650 +- 0.350 uTm 19:28:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:28:36 Integrated Voltage Measurement... 19:28:45 Voltage Offset Correction: v_off_ini = 600.294 uV, v_off_fin = 579.449 uV 19:28:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.109 uVs 19:28:45 Integrated Voltage Measurement... 19:28:54 Voltage Offset Correction: v_off_ini = 603.492 uV, v_off_fin = 609.222 uV 19:28:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.180 uVs 19:28:54 Integrated Voltage Measurement... 19:29:03 Voltage Offset Correction: v_off_ini = 601.501 uV, v_off_fin = 593.825 uV 19:29:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.671 uVs 19:29:03 Integrated Voltage Measurement... 19:29:12 Voltage Offset Correction: v_off_ini = 600.928 uV, v_off_fin = 610.280 uV 19:29:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.415 uVs 19:29:12 Integrated Voltage Measurement... 19:29:21 Voltage Offset Correction: v_off_ini = 597.247 uV, v_off_fin = 595.312 uV 19:29:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.170 uVs 19:29:21 Integrated Voltage Measurement... 19:29:30 Voltage Offset Correction: v_off_ini = 598.131 uV, v_off_fin = 603.131 uV 19:29:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.692 uVs 19:29:35 I1Y Average and RMS of Measurements VT = -228.039 +- 3.828 uVs I1Y = -45.608 +- 0.766 uTm 19:29:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:29:40 Integrated Voltage Measurement... 19:29:49 Voltage Offset Correction: v_off_ini = 581.469 uV, v_off_fin = 582.855 uV 19:29:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.868 uVs 19:29:49 Integrated Voltage Measurement... 19:29:58 Voltage Offset Correction: v_off_ini = 605.671 uV, v_off_fin = 610.976 uV 19:29:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.650 uVs 19:29:58 Integrated Voltage Measurement... 19:30:07 Voltage Offset Correction: v_off_ini = 611.582 uV, v_off_fin = 609.446 uV 19:30:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.829 uVs 19:30:07 Integrated Voltage Measurement... 19:30:16 Voltage Offset Correction: v_off_ini = 610.259 uV, v_off_fin = 627.065 uV 19:30:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.334 uVs 19:30:16 Integrated Voltage Measurement... 19:30:25 Voltage Offset Correction: v_off_ini = 617.128 uV, v_off_fin = 608.943 uV 19:30:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.073 uVs 19:30:25 Integrated Voltage Measurement... 19:30:34 Voltage Offset Correction: v_off_ini = 614.069 uV, v_off_fin = 625.616 uV 19:30:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.545 uVs 19:30:36 I2X Average and RMS of Measurements VT = -111.717 +- 5.395 uVs I2X = 10.278 +- 0.496 uTm^2 19:30:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:30:42 Integrated Voltage Measurement... 19:30:50 Voltage Offset Correction: v_off_ini = 624.137 uV, v_off_fin = 620.157 uV 19:30:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.475 uVs 19:30:51 Integrated Voltage Measurement... 19:31:00 Voltage Offset Correction: v_off_ini = 620.167 uV, v_off_fin = 630.260 uV 19:31:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 237.952 uVs 19:31:00 Integrated Voltage Measurement... 19:31:09 Voltage Offset Correction: v_off_ini = 645.405 uV, v_off_fin = 638.268 uV 19:31:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.751 uVs 19:31:09 Integrated Voltage Measurement... 19:31:18 Voltage Offset Correction: v_off_ini = 645.468 uV, v_off_fin = 642.134 uV 19:31:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.711 uVs 19:31:18 Integrated Voltage Measurement... 19:31:27 Voltage Offset Correction: v_off_ini = 635.757 uV, v_off_fin = 635.256 uV 19:31:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.288 uVs 19:31:27 Integrated Voltage Measurement... 19:31:36 Voltage Offset Correction: v_off_ini = 658.937 uV, v_off_fin = 651.864 uV 19:31:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.724 uVs 19:31:38 I2Y Average and RMS of Measurements VT = -249.484 +- 10.916 uVs I2Y = -22.953 +- 1.005 uTm^2 19:31:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:31:46 Integrated Voltage Measurement... 19:31:55 Voltage Offset Correction: v_off_ini = 651.406 uV, v_off_fin = 650.417 uV 19:31:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.776 uVs 19:31:56 Integrated Voltage Measurement... 19:32:04 Voltage Offset Correction: v_off_ini = 654.091 uV, v_off_fin = 660.971 uV 19:32:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.722 uVs 19:32:05 Integrated Voltage Measurement... 19:32:14 Voltage Offset Correction: v_off_ini = 641.765 uV, v_off_fin = 659.237 uV 19:32:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.355 uVs 19:32:14 Integrated Voltage Measurement... 19:32:23 Voltage Offset Correction: v_off_ini = 677.182 uV, v_off_fin = 661.200 uV 19:32:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.560 uVs 19:32:23 Integrated Voltage Measurement... 19:32:32 Voltage Offset Correction: v_off_ini = 631.867 uV, v_off_fin = 656.585 uV 19:32:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.787 uVs 19:32:32 Integrated Voltage Measurement... 19:32:41 Voltage Offset Correction: v_off_ini = 667.098 uV, v_off_fin = 656.750 uV 19:32:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.028 uVs 19:32:45 I1X Average and RMS of Measurements VT = -72.205 +- 4.473 uVs I1X = 14.441 +- 0.895 uTm 19:32:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:32:52 Integrated Voltage Measurement... 19:33:01 Voltage Offset Correction: v_off_ini = 645.690 uV, v_off_fin = 639.976 uV 19:33:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.429 uVs 19:33:01 Integrated Voltage Measurement... 19:33:10 Voltage Offset Correction: v_off_ini = 639.048 uV, v_off_fin = 661.435 uV 19:33:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.950 uVs 19:33:10 Integrated Voltage Measurement... 19:33:19 Voltage Offset Correction: v_off_ini = 668.027 uV, v_off_fin = 667.238 uV 19:33:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.716 uVs 19:33:19 Integrated Voltage Measurement... 19:33:28 Voltage Offset Correction: v_off_ini = 658.845 uV, v_off_fin = 664.779 uV 19:33:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.839 uVs 19:33:28 Integrated Voltage Measurement... 19:33:37 Voltage Offset Correction: v_off_ini = 650.533 uV, v_off_fin = 625.762 uV 19:33:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.174 uVs 19:33:37 Integrated Voltage Measurement... 19:33:46 Voltage Offset Correction: v_off_ini = 649.301 uV, v_off_fin = 666.791 uV 19:33:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.501 uVs 19:33:50 I1Y Average and RMS of Measurements VT = -209.601 +- 1.970 uVs I1Y = -41.919 +- 0.392 uTm 19:33:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:33:55 Integrated Voltage Measurement... 19:34:04 Voltage Offset Correction: v_off_ini = 634.918 uV, v_off_fin = 630.957 uV 19:34:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.893 uVs 19:34:04 Integrated Voltage Measurement... 19:34:13 Voltage Offset Correction: v_off_ini = 648.025 uV, v_off_fin = 652.713 uV 19:34:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.857 uVs 19:34:13 Integrated Voltage Measurement... 19:34:22 Voltage Offset Correction: v_off_ini = 634.058 uV, v_off_fin = 606.934 uV 19:34:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.665 uVs 19:34:22 Integrated Voltage Measurement... 19:34:31 Voltage Offset Correction: v_off_ini = 622.574 uV, v_off_fin = 640.197 uV 19:34:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.902 uVs 19:34:31 Integrated Voltage Measurement... 19:34:40 Voltage Offset Correction: v_off_ini = 639.302 uV, v_off_fin = 631.178 uV 19:34:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.419 uVs 19:34:40 Integrated Voltage Measurement... 19:34:49 Voltage Offset Correction: v_off_ini = 620.568 uV, v_off_fin = 627.624 uV 19:34:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.445 uVs 19:34:52 I2X Average and RMS of Measurements VT = -101.697 +- 19.400 uVs I2X = 9.356 +- 1.785 uTm^2 19:34:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:34:57 Integrated Voltage Measurement... 19:35:06 Voltage Offset Correction: v_off_ini = 634.998 uV, v_off_fin = 619.771 uV 19:35:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.408 uVs 19:35:06 Integrated Voltage Measurement... 19:35:15 Voltage Offset Correction: v_off_ini = 619.620 uV, v_off_fin = 620.425 uV 19:35:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.511 uVs 19:35:15 Integrated Voltage Measurement... 19:35:24 Voltage Offset Correction: v_off_ini = 640.600 uV, v_off_fin = 624.240 uV 19:35:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.944 uVs 19:35:24 Integrated Voltage Measurement... 19:35:33 Voltage Offset Correction: v_off_ini = 633.516 uV, v_off_fin = 638.702 uV 19:35:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.372 uVs 19:35:33 Integrated Voltage Measurement... 19:35:42 Voltage Offset Correction: v_off_ini = 635.641 uV, v_off_fin = 614.275 uV 19:35:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.452 uVs 19:35:42 Integrated Voltage Measurement... 19:35:51 Voltage Offset Correction: v_off_ini = 634.218 uV, v_off_fin = 625.048 uV 19:35:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.683 uVs 19:35:53 I2Y Average and RMS of Measurements VT = -252.895 +- 11.130 uVs I2Y = -23.266 +- 1.024 uTm^2 19:35:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:36:02 Integrated Voltage Measurement... 19:36:11 Voltage Offset Correction: v_off_ini = 646.526 uV, v_off_fin = 640.613 uV 19:36:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -78.120 uVs 19:36:11 Integrated Voltage Measurement... 19:36:20 Voltage Offset Correction: v_off_ini = 633.569 uV, v_off_fin = 619.381 uV 19:36:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.315 uVs 19:36:20 Integrated Voltage Measurement... 19:36:29 Voltage Offset Correction: v_off_ini = 631.019 uV, v_off_fin = 630.693 uV 19:36:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.104 uVs 19:36:29 Integrated Voltage Measurement... 19:36:38 Voltage Offset Correction: v_off_ini = 635.716 uV, v_off_fin = 628.337 uV 19:36:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.735 uVs 19:36:38 Integrated Voltage Measurement... 19:36:47 Voltage Offset Correction: v_off_ini = 627.624 uV, v_off_fin = 624.531 uV 19:36:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.891 uVs 19:36:47 Integrated Voltage Measurement... 19:36:56 Voltage Offset Correction: v_off_ini = 615.735 uV, v_off_fin = 631.893 uV 19:36:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.905 uVs 19:37:00 I1X Average and RMS of Measurements VT = -83.512 +- 4.558 uVs I1X = 16.703 +- 0.912 uTm 19:37:03 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:37:07 Integrated Voltage Measurement... 19:37:16 Voltage Offset Correction: v_off_ini = 627.465 uV, v_off_fin = 634.607 uV 19:37:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -209.833 uVs 19:37:16 Integrated Voltage Measurement... 19:37:25 Voltage Offset Correction: v_off_ini = 638.271 uV, v_off_fin = 651.035 uV 19:37:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.870 uVs 19:37:25 Integrated Voltage Measurement... 19:37:34 Voltage Offset Correction: v_off_ini = 629.674 uV, v_off_fin = 616.588 uV 19:37:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.657 uVs 19:37:34 Integrated Voltage Measurement... 19:37:43 Voltage Offset Correction: v_off_ini = 622.624 uV, v_off_fin = 644.617 uV 19:37:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.700 uVs 19:37:43 Integrated Voltage Measurement... 19:37:52 Voltage Offset Correction: v_off_ini = 652.702 uV, v_off_fin = 638.676 uV 19:37:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.404 uVs 19:37:52 Integrated Voltage Measurement... 19:38:01 Voltage Offset Correction: v_off_ini = 653.756 uV, v_off_fin = 668.883 uV 19:38:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.315 uVs 19:38:05 I1Y Average and RMS of Measurements VT = -219.296 +- 2.400 uVs I1Y = -43.858 +- 0.478 uTm 19:38:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:38:10 Integrated Voltage Measurement... 19:38:19 Voltage Offset Correction: v_off_ini = 639.647 uV, v_off_fin = 626.209 uV 19:38:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.592 uVs 19:38:19 Integrated Voltage Measurement... 19:38:28 Voltage Offset Correction: v_off_ini = 606.525 uV, v_off_fin = 640.679 uV 19:38:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.334 uVs 19:38:28 Integrated Voltage Measurement... 19:38:37 Voltage Offset Correction: v_off_ini = 639.387 uV, v_off_fin = 637.027 uV 19:38:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.510 uVs 19:38:37 Integrated Voltage Measurement... 19:38:46 Voltage Offset Correction: v_off_ini = 626.735 uV, v_off_fin = 642.512 uV 19:38:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.585 uVs 19:38:46 Integrated Voltage Measurement... 19:38:55 Voltage Offset Correction: v_off_ini = 650.831 uV, v_off_fin = 624.482 uV 19:38:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.380 uVs 19:38:56 Integrated Voltage Measurement... 19:39:05 Voltage Offset Correction: v_off_ini = 631.778 uV, v_off_fin = 643.339 uV 19:39:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.259 uVs 19:39:07 I2X Average and RMS of Measurements VT = -99.943 +- 10.454 uVs I2X = 9.195 +- 0.962 uTm^2 19:39:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:39:12 Integrated Voltage Measurement... 19:39:21 Voltage Offset Correction: v_off_ini = 618.425 uV, v_off_fin = 630.037 uV 19:39:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.129 uVs 19:39:21 Integrated Voltage Measurement... 19:39:30 Voltage Offset Correction: v_off_ini = 629.189 uV, v_off_fin = 635.851 uV 19:39:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.942 uVs 19:39:30 Integrated Voltage Measurement... 19:39:39 Voltage Offset Correction: v_off_ini = 648.346 uV, v_off_fin = 641.943 uV 19:39:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.054 uVs 19:39:39 Integrated Voltage Measurement... 19:39:48 Voltage Offset Correction: v_off_ini = 634.352 uV, v_off_fin = 632.599 uV 19:39:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.371 uVs 19:39:48 Integrated Voltage Measurement... 19:39:57 Voltage Offset Correction: v_off_ini = 639.132 uV, v_off_fin = 639.656 uV 19:39:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.067 uVs 19:39:57 Integrated Voltage Measurement... 19:40:06 Voltage Offset Correction: v_off_ini = 636.404 uV, v_off_fin = 618.978 uV 19:40:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.136 uVs 19:40:09 I2Y Average and RMS of Measurements VT = -249.616 +- 9.324 uVs I2Y = -22.965 +- 0.858 uTm^2 19:40:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm