SLAC Magnetic Measurements Date: 12-13-2024 Time: 11:21:08 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10084 Dataset Number: 1 Run Purpose: Final Results Run Type: On Axis Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 11:22:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:09 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:22:10 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:22:12 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:22:14 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:26:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:26:17 Integrated Voltage Measurement... 11:26:26 Voltage Offset Correction: v_off_ini = 789.915 uV, v_off_fin = 794.865 uV 11:26:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.181 uVs 11:26:26 Integrated Voltage Measurement... 11:26:35 Voltage Offset Correction: v_off_ini = 796.291 uV, v_off_fin = 782.951 uV 11:26:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.135 uVs 11:26:35 Integrated Voltage Measurement... 11:26:44 Voltage Offset Correction: v_off_ini = 783.935 uV, v_off_fin = 779.950 uV 11:26:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.359 uVs 11:26:44 Integrated Voltage Measurement... 11:26:53 Voltage Offset Correction: v_off_ini = 791.292 uV, v_off_fin = 785.636 uV 11:26:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.439 uVs 11:26:53 Integrated Voltage Measurement... 11:27:02 Voltage Offset Correction: v_off_ini = 788.303 uV, v_off_fin = 786.262 uV 11:27:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.150 uVs 11:27:02 Integrated Voltage Measurement... 11:27:11 Voltage Offset Correction: v_off_ini = 767.037 uV, v_off_fin = 783.217 uV 11:27:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.101 uVs 11:27:15 I1X Average and RMS of Measurements VT = -101.561 +- 4.948 uVs I1X = 20.313 +- 0.990 uTm 11:27:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:27:22 Integrated Voltage Measurement... 11:27:31 Voltage Offset Correction: v_off_ini = 757.368 uV, v_off_fin = 751.123 uV 11:27:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.141 uVs 11:27:31 Integrated Voltage Measurement... 11:27:40 Voltage Offset Correction: v_off_ini = 776.904 uV, v_off_fin = 788.552 uV 11:27:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.522 uVs 11:27:40 Integrated Voltage Measurement... 11:27:49 Voltage Offset Correction: v_off_ini = 782.000 uV, v_off_fin = 749.228 uV 11:27:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.431 uVs 11:27:49 Integrated Voltage Measurement... 11:27:58 Voltage Offset Correction: v_off_ini = 777.886 uV, v_off_fin = 785.820 uV 11:27:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.473 uVs 11:27:58 Integrated Voltage Measurement... 11:28:07 Voltage Offset Correction: v_off_ini = 787.964 uV, v_off_fin = 767.436 uV 11:28:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.114 uVs 11:28:07 Integrated Voltage Measurement... 11:28:16 Voltage Offset Correction: v_off_ini = 772.658 uV, v_off_fin = 779.592 uV 11:28:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.583 uVs 11:28:20 I1Y Average and RMS of Measurements VT = -240.711 +- 7.325 uVs I1Y = -48.142 +- 1.465 uTm 11:28:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:28:28 Integrated Voltage Measurement... 11:28:37 Voltage Offset Correction: v_off_ini = 772.891 uV, v_off_fin = 768.892 uV 11:28:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.553 uVs 11:28:37 Integrated Voltage Measurement... 11:28:46 Voltage Offset Correction: v_off_ini = 756.852 uV, v_off_fin = 767.251 uV 11:28:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.049 uVs 11:28:46 Integrated Voltage Measurement... 11:28:55 Voltage Offset Correction: v_off_ini = 762.138 uV, v_off_fin = 757.332 uV 11:28:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.845 uVs 11:28:55 Integrated Voltage Measurement... 11:29:04 Voltage Offset Correction: v_off_ini = 767.935 uV, v_off_fin = 763.342 uV 11:29:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.168 uVs 11:29:04 Integrated Voltage Measurement... 11:29:13 Voltage Offset Correction: v_off_ini = 759.096 uV, v_off_fin = 743.875 uV 11:29:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.718 uVs 11:29:13 Integrated Voltage Measurement... 11:29:22 Voltage Offset Correction: v_off_ini = 761.491 uV, v_off_fin = 749.722 uV 11:29:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.881 uVs 11:29:25 I2X Average and RMS of Measurements VT = -137.035 +- 5.227 uVs I2X = 12.607 +- 0.481 uTm^2 11:29:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:29:32 Integrated Voltage Measurement... 11:29:41 Voltage Offset Correction: v_off_ini = 722.642 uV, v_off_fin = 712.825 uV 11:29:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.043 uVs 11:29:41 Integrated Voltage Measurement... 11:29:50 Voltage Offset Correction: v_off_ini = 732.779 uV, v_off_fin = 718.509 uV 11:29:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.648 uVs 11:29:51 Integrated Voltage Measurement... 11:30:00 Voltage Offset Correction: v_off_ini = 709.225 uV, v_off_fin = 714.594 uV 11:30:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.944 uVs 11:30:00 Integrated Voltage Measurement... 11:30:09 Voltage Offset Correction: v_off_ini = 735.817 uV, v_off_fin = 715.855 uV 11:30:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.055 uVs 11:30:09 Integrated Voltage Measurement... 11:30:18 Voltage Offset Correction: v_off_ini = 696.803 uV, v_off_fin = 701.425 uV 11:30:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.090 uVs 11:30:18 Integrated Voltage Measurement... 11:30:27 Voltage Offset Correction: v_off_ini = 712.738 uV, v_off_fin = 706.834 uV 11:30:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.387 uVs 11:30:29 I2Y Average and RMS of Measurements VT = -338.861 +- 11.163 uVs I2Y = -31.175 +- 1.027 uTm^2 11:30:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:30:43 Integrated Voltage Measurement... 11:30:52 Voltage Offset Correction: v_off_ini = 727.487 uV, v_off_fin = 714.992 uV 11:30:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.726 uVs 11:30:52 Integrated Voltage Measurement... 11:31:01 Voltage Offset Correction: v_off_ini = 703.814 uV, v_off_fin = 721.306 uV 11:31:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.564 uVs 11:31:01 Integrated Voltage Measurement... 11:31:10 Voltage Offset Correction: v_off_ini = 731.671 uV, v_off_fin = 721.022 uV 11:31:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.703 uVs 11:31:10 Integrated Voltage Measurement... 11:31:19 Voltage Offset Correction: v_off_ini = 716.275 uV, v_off_fin = 708.382 uV 11:31:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.099 uVs 11:31:19 Integrated Voltage Measurement... 11:31:28 Voltage Offset Correction: v_off_ini = 718.834 uV, v_off_fin = 710.374 uV 11:31:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.552 uVs 11:31:28 Integrated Voltage Measurement... 11:31:37 Voltage Offset Correction: v_off_ini = 712.670 uV, v_off_fin = 724.718 uV 11:31:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.001 uVs 11:31:41 I1X Average and RMS of Measurements VT = -110.441 +- 4.649 uVs I1X = 22.088 +- 0.930 uTm 11:31:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:48 Integrated Voltage Measurement... 11:31:57 Voltage Offset Correction: v_off_ini = 707.213 uV, v_off_fin = 710.702 uV 11:31:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.171 uVs 11:31:57 Integrated Voltage Measurement... 11:32:06 Voltage Offset Correction: v_off_ini = 719.470 uV, v_off_fin = 726.719 uV 11:32:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.549 uVs 11:32:06 Integrated Voltage Measurement... 11:32:15 Voltage Offset Correction: v_off_ini = 728.471 uV, v_off_fin = 717.237 uV 11:32:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.268 uVs 11:32:15 Integrated Voltage Measurement... 11:32:24 Voltage Offset Correction: v_off_ini = 710.735 uV, v_off_fin = 718.779 uV 11:32:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.124 uVs 11:32:24 Integrated Voltage Measurement... 11:32:33 Voltage Offset Correction: v_off_ini = 700.434 uV, v_off_fin = 699.119 uV 11:32:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.660 uVs 11:32:33 Integrated Voltage Measurement... 11:32:42 Voltage Offset Correction: v_off_ini = 702.810 uV, v_off_fin = 707.225 uV 11:32:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.968 uVs 11:32:46 I1Y Average and RMS of Measurements VT = -232.957 +- 5.021 uVs I1Y = -46.591 +- 1.004 uTm 11:32:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:32:54 Integrated Voltage Measurement... 11:33:03 Voltage Offset Correction: v_off_ini = 714.812 uV, v_off_fin = 718.481 uV 11:33:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.726 uVs 11:33:03 Integrated Voltage Measurement... 11:33:12 Voltage Offset Correction: v_off_ini = 724.143 uV, v_off_fin = 744.876 uV 11:33:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.934 uVs 11:33:12 Integrated Voltage Measurement... 11:33:21 Voltage Offset Correction: v_off_ini = 718.808 uV, v_off_fin = 703.624 uV 11:33:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.968 uVs 11:33:21 Integrated Voltage Measurement... 11:33:30 Voltage Offset Correction: v_off_ini = 724.540 uV, v_off_fin = 727.506 uV 11:33:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.061 uVs 11:33:30 Integrated Voltage Measurement... 11:33:39 Voltage Offset Correction: v_off_ini = 712.143 uV, v_off_fin = 721.725 uV 11:33:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.668 uVs 11:33:39 Integrated Voltage Measurement... 11:33:48 Voltage Offset Correction: v_off_ini = 717.875 uV, v_off_fin = 717.059 uV 11:33:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.611 uVs 11:33:51 I2X Average and RMS of Measurements VT = -131.328 +- 3.420 uVs I2X = 12.082 +- 0.315 uTm^2 11:33:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:33:58 Integrated Voltage Measurement... 11:34:07 Voltage Offset Correction: v_off_ini = 710.483 uV, v_off_fin = 704.746 uV 11:34:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.333 uVs 11:34:07 Integrated Voltage Measurement... 11:34:16 Voltage Offset Correction: v_off_ini = 696.144 uV, v_off_fin = 707.383 uV 11:34:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.436 uVs 11:34:16 Integrated Voltage Measurement... 11:34:25 Voltage Offset Correction: v_off_ini = 709.418 uV, v_off_fin = 702.332 uV 11:34:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.818 uVs 11:34:25 Integrated Voltage Measurement... 11:34:34 Voltage Offset Correction: v_off_ini = 693.516 uV, v_off_fin = 693.074 uV 11:34:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.422 uVs 11:34:34 Integrated Voltage Measurement... 11:34:43 Voltage Offset Correction: v_off_ini = 679.552 uV, v_off_fin = 694.487 uV 11:34:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.224 uVs 11:34:43 Integrated Voltage Measurement... 11:34:52 Voltage Offset Correction: v_off_ini = 684.984 uV, v_off_fin = 678.283 uV 11:34:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.959 uVs 11:34:55 I2Y Average and RMS of Measurements VT = -341.199 +- 1.911 uVs I2Y = -31.390 +- 0.176 uTm^2 11:35:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:35:09 Integrated Voltage Measurement... 11:35:18 Voltage Offset Correction: v_off_ini = 692.182 uV, v_off_fin = 693.926 uV 11:35:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.513 uVs 11:35:18 Integrated Voltage Measurement... 11:35:27 Voltage Offset Correction: v_off_ini = 685.119 uV, v_off_fin = 689.578 uV 11:35:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.723 uVs 11:35:27 Integrated Voltage Measurement... 11:35:36 Voltage Offset Correction: v_off_ini = 689.681 uV, v_off_fin = 695.238 uV 11:35:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.668 uVs 11:35:36 Integrated Voltage Measurement... 11:35:45 Voltage Offset Correction: v_off_ini = 709.718 uV, v_off_fin = 702.413 uV 11:35:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.260 uVs 11:35:45 Integrated Voltage Measurement... 11:35:54 Voltage Offset Correction: v_off_ini = 709.502 uV, v_off_fin = 678.147 uV 11:35:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.686 uVs 11:35:54 Integrated Voltage Measurement... 11:36:03 Voltage Offset Correction: v_off_ini = 705.043 uV, v_off_fin = 695.870 uV 11:36:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.143 uVs 11:36:07 I1X Average and RMS of Measurements VT = -98.999 +- 7.924 uVs I1X = 19.801 +- 1.585 uTm 11:36:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:14 Integrated Voltage Measurement... 11:36:23 Voltage Offset Correction: v_off_ini = 689.011 uV, v_off_fin = 687.600 uV 11:36:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.253 uVs 11:36:23 Integrated Voltage Measurement... 11:36:32 Voltage Offset Correction: v_off_ini = 684.575 uV, v_off_fin = 689.563 uV 11:36:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.984 uVs 11:36:32 Integrated Voltage Measurement... 11:36:41 Voltage Offset Correction: v_off_ini = 689.514 uV, v_off_fin = 685.036 uV 11:36:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.500 uVs 11:36:41 Integrated Voltage Measurement... 11:36:50 Voltage Offset Correction: v_off_ini = 680.395 uV, v_off_fin = 701.578 uV 11:36:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.386 uVs 11:36:50 Integrated Voltage Measurement... 11:36:59 Voltage Offset Correction: v_off_ini = 694.551 uV, v_off_fin = 695.905 uV 11:36:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.283 uVs 11:36:59 Integrated Voltage Measurement... 11:37:08 Voltage Offset Correction: v_off_ini = 694.108 uV, v_off_fin = 705.647 uV 11:37:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.237 uVs 11:37:12 I1Y Average and RMS of Measurements VT = -234.107 +- 0.727 uVs I1Y = -46.821 +- 0.145 uTm 11:37:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:37:20 Integrated Voltage Measurement... 11:37:29 Voltage Offset Correction: v_off_ini = 681.288 uV, v_off_fin = 666.481 uV 11:37:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.313 uVs 11:37:29 Integrated Voltage Measurement... 11:37:38 Voltage Offset Correction: v_off_ini = 706.674 uV, v_off_fin = 687.775 uV 11:37:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.025 uVs 11:37:38 Integrated Voltage Measurement... 11:37:47 Voltage Offset Correction: v_off_ini = 677.643 uV, v_off_fin = 667.532 uV 11:37:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.708 uVs 11:37:47 Integrated Voltage Measurement... 11:37:56 Voltage Offset Correction: v_off_ini = 666.498 uV, v_off_fin = 685.228 uV 11:37:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.839 uVs 11:37:56 Integrated Voltage Measurement... 11:38:05 Voltage Offset Correction: v_off_ini = 681.664 uV, v_off_fin = 683.268 uV 11:38:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.163 uVs 11:38:05 Integrated Voltage Measurement... 11:38:14 Voltage Offset Correction: v_off_ini = 686.110 uV, v_off_fin = 690.135 uV 11:38:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.617 uVs 11:38:16 I2X Average and RMS of Measurements VT = -131.944 +- 8.121 uVs I2X = 12.139 +- 0.747 uTm^2 11:38:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:38:24 Integrated Voltage Measurement... 11:38:33 Voltage Offset Correction: v_off_ini = 686.085 uV, v_off_fin = 672.039 uV 11:38:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.219 uVs 11:38:33 Integrated Voltage Measurement... 11:38:42 Voltage Offset Correction: v_off_ini = 685.485 uV, v_off_fin = 671.970 uV 11:38:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 333.377 uVs 11:38:42 Integrated Voltage Measurement... 11:38:51 Voltage Offset Correction: v_off_ini = 678.268 uV, v_off_fin = 681.902 uV 11:38:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.309 uVs 11:38:51 Integrated Voltage Measurement... 11:39:00 Voltage Offset Correction: v_off_ini = 665.763 uV, v_off_fin = 677.816 uV 11:39:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.129 uVs 11:39:00 Integrated Voltage Measurement... 11:39:09 Voltage Offset Correction: v_off_ini = 662.398 uV, v_off_fin = 679.999 uV 11:39:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.496 uVs 11:39:09 Integrated Voltage Measurement... 11:39:18 Voltage Offset Correction: v_off_ini = 679.910 uV, v_off_fin = 670.088 uV 11:39:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.777 uVs 11:39:21 I2Y Average and RMS of Measurements VT = -322.385 +- 10.504 uVs I2Y = -29.660 +- 0.967 uTm^2 11:39:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:35 Integrated Voltage Measurement... 11:39:44 Voltage Offset Correction: v_off_ini = 693.889 uV, v_off_fin = 673.869 uV 11:39:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -115.309 uVs 11:39:44 Integrated Voltage Measurement... 11:39:53 Voltage Offset Correction: v_off_ini = 675.172 uV, v_off_fin = 683.308 uV 11:39:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.148 uVs 11:39:53 Integrated Voltage Measurement... 11:40:02 Voltage Offset Correction: v_off_ini = 676.035 uV, v_off_fin = 674.819 uV 11:40:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.937 uVs 11:40:02 Integrated Voltage Measurement... 11:40:11 Voltage Offset Correction: v_off_ini = 669.878 uV, v_off_fin = 657.998 uV 11:40:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.925 uVs 11:40:11 Integrated Voltage Measurement... 11:40:20 Voltage Offset Correction: v_off_ini = 656.456 uV, v_off_fin = 674.999 uV 11:40:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.583 uVs 11:40:20 Integrated Voltage Measurement... 11:40:29 Voltage Offset Correction: v_off_ini = 670.774 uV, v_off_fin = 683.848 uV 11:40:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.561 uVs 11:40:33 I1X Average and RMS of Measurements VT = -101.411 +- 5.591 uVs I1X = 20.282 +- 1.119 uTm 11:40:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:40:40 Integrated Voltage Measurement... 11:40:49 Voltage Offset Correction: v_off_ini = 679.723 uV, v_off_fin = 669.479 uV 11:40:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -250.540 uVs 11:40:49 Integrated Voltage Measurement... 11:40:58 Voltage Offset Correction: v_off_ini = 677.981 uV, v_off_fin = 684.232 uV 11:40:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.992 uVs 11:40:58 Integrated Voltage Measurement... 11:41:07 Voltage Offset Correction: v_off_ini = 671.078 uV, v_off_fin = 663.081 uV 11:41:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.939 uVs 11:41:07 Integrated Voltage Measurement... 11:41:16 Voltage Offset Correction: v_off_ini = 672.612 uV, v_off_fin = 683.651 uV 11:41:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.472 uVs 11:41:16 Integrated Voltage Measurement... 11:41:25 Voltage Offset Correction: v_off_ini = 680.026 uV, v_off_fin = 680.830 uV 11:41:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.446 uVs 11:41:25 Integrated Voltage Measurement... 11:41:34 Voltage Offset Correction: v_off_ini = 683.843 uV, v_off_fin = 696.845 uV 11:41:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.176 uVs 11:41:38 I1Y Average and RMS of Measurements VT = -246.261 +- 5.712 uVs I1Y = -49.254 +- 1.144 uTm 11:41:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:41:46 Integrated Voltage Measurement... 11:41:55 Voltage Offset Correction: v_off_ini = 690.819 uV, v_off_fin = 692.451 uV 11:41:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -120.142 uVs 11:41:55 Integrated Voltage Measurement... 11:42:04 Voltage Offset Correction: v_off_ini = 706.162 uV, v_off_fin = 710.285 uV 11:42:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.498 uVs 11:42:04 Integrated Voltage Measurement... 11:42:13 Voltage Offset Correction: v_off_ini = 714.648 uV, v_off_fin = 696.779 uV 11:42:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.066 uVs 11:42:13 Integrated Voltage Measurement... 11:42:22 Voltage Offset Correction: v_off_ini = 708.918 uV, v_off_fin = 708.500 uV 11:42:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.439 uVs 11:42:22 Integrated Voltage Measurement... 11:42:31 Voltage Offset Correction: v_off_ini = 710.479 uV, v_off_fin = 706.508 uV 11:42:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.125 uVs 11:42:31 Integrated Voltage Measurement... 11:42:40 Voltage Offset Correction: v_off_ini = 721.863 uV, v_off_fin = 730.715 uV 11:42:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.375 uVs 11:42:42 I2X Average and RMS of Measurements VT = -130.441 +- 3.293 uVs I2X = 12.000 +- 0.303 uTm^2 11:42:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:42:50 Integrated Voltage Measurement... 11:42:59 Voltage Offset Correction: v_off_ini = 716.947 uV, v_off_fin = 713.118 uV 11:42:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.493 uVs 11:42:59 Integrated Voltage Measurement... 11:43:08 Voltage Offset Correction: v_off_ini = 717.268 uV, v_off_fin = 741.944 uV 11:43:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.286 uVs 11:43:08 Integrated Voltage Measurement... 11:43:17 Voltage Offset Correction: v_off_ini = 742.220 uV, v_off_fin = 735.756 uV 11:43:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.214 uVs 11:43:17 Integrated Voltage Measurement... 11:43:26 Voltage Offset Correction: v_off_ini = 733.732 uV, v_off_fin = 735.489 uV 11:43:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.081 uVs 11:43:26 Integrated Voltage Measurement... 11:43:35 Voltage Offset Correction: v_off_ini = 728.926 uV, v_off_fin = 728.862 uV 11:43:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.477 uVs 11:43:35 Integrated Voltage Measurement... 11:43:44 Voltage Offset Correction: v_off_ini = 749.702 uV, v_off_fin = 737.641 uV 11:43:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.486 uVs 11:43:46 I2Y Average and RMS of Measurements VT = -328.839 +- 8.207 uVs I2Y = -30.253 +- 0.755 uTm^2 11:43:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:44:00 Integrated Voltage Measurement... 11:44:09 Voltage Offset Correction: v_off_ini = 749.820 uV, v_off_fin = 728.904 uV 11:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -123.719 uVs 11:44:09 Integrated Voltage Measurement... 11:44:18 Voltage Offset Correction: v_off_ini = 731.526 uV, v_off_fin = 728.432 uV 11:44:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.508 uVs 11:44:18 Integrated Voltage Measurement... 11:44:27 Voltage Offset Correction: v_off_ini = 750.890 uV, v_off_fin = 750.779 uV 11:44:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.705 uVs 11:44:27 Integrated Voltage Measurement... 11:44:36 Voltage Offset Correction: v_off_ini = 761.097 uV, v_off_fin = 736.387 uV 11:44:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.763 uVs 11:44:36 Integrated Voltage Measurement... 11:44:45 Voltage Offset Correction: v_off_ini = 726.849 uV, v_off_fin = 746.249 uV 11:44:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.969 uVs 11:44:45 Integrated Voltage Measurement... 11:44:54 Voltage Offset Correction: v_off_ini = 758.454 uV, v_off_fin = 750.325 uV 11:44:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.260 uVs 11:44:58 I1X Average and RMS of Measurements VT = -98.154 +- 21.637 uVs I1X = 19.631 +- 4.328 uTm 11:45:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:05 Integrated Voltage Measurement... 11:45:14 Voltage Offset Correction: v_off_ini = 748.299 uV, v_off_fin = 736.177 uV 11:45:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -252.236 uVs 11:45:14 Integrated Voltage Measurement... 11:45:23 Voltage Offset Correction: v_off_ini = 721.499 uV, v_off_fin = 730.682 uV 11:45:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.164 uVs 11:45:23 Integrated Voltage Measurement... 11:45:32 Voltage Offset Correction: v_off_ini = 736.175 uV, v_off_fin = 732.443 uV 11:45:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.796 uVs 11:45:32 Integrated Voltage Measurement... 11:45:41 Voltage Offset Correction: v_off_ini = 759.177 uV, v_off_fin = 767.426 uV 11:45:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.240 uVs 11:45:41 Integrated Voltage Measurement... 11:45:50 Voltage Offset Correction: v_off_ini = 745.049 uV, v_off_fin = 735.752 uV 11:45:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.547 uVs 11:45:50 Integrated Voltage Measurement... 11:45:59 Voltage Offset Correction: v_off_ini = 750.000 uV, v_off_fin = 756.657 uV 11:45:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.180 uVs 11:46:03 I1Y Average and RMS of Measurements VT = -247.861 +- 3.699 uVs I1Y = -49.573 +- 0.741 uTm 11:46:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:46:11 Integrated Voltage Measurement... 11:46:20 Voltage Offset Correction: v_off_ini = 739.617 uV, v_off_fin = 765.240 uV 11:46:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.533 uVs 11:46:20 Integrated Voltage Measurement... 11:46:29 Voltage Offset Correction: v_off_ini = 760.597 uV, v_off_fin = 774.393 uV 11:46:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.611 uVs 11:46:29 Integrated Voltage Measurement... 11:46:38 Voltage Offset Correction: v_off_ini = 749.540 uV, v_off_fin = 742.627 uV 11:46:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.866 uVs 11:46:38 Integrated Voltage Measurement... 11:46:47 Voltage Offset Correction: v_off_ini = 767.734 uV, v_off_fin = 765.450 uV 11:46:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.598 uVs 11:46:47 Integrated Voltage Measurement... 11:46:56 Voltage Offset Correction: v_off_ini = 772.534 uV, v_off_fin = 755.255 uV 11:46:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.010 uVs 11:46:56 Integrated Voltage Measurement... 11:47:05 Voltage Offset Correction: v_off_ini = 748.862 uV, v_off_fin = 760.460 uV 11:47:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.964 uVs 11:47:08 I2X Average and RMS of Measurements VT = -120.430 +- 9.603 uVs I2X = 11.080 +- 0.883 uTm^2 11:47:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:15 Integrated Voltage Measurement... 11:47:24 Voltage Offset Correction: v_off_ini = 737.991 uV, v_off_fin = 734.793 uV 11:47:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.355 uVs 11:47:25 Integrated Voltage Measurement... 11:47:34 Voltage Offset Correction: v_off_ini = 732.242 uV, v_off_fin = 720.647 uV 11:47:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.779 uVs 11:47:34 Integrated Voltage Measurement... 11:47:43 Voltage Offset Correction: v_off_ini = 728.314 uV, v_off_fin = 721.297 uV 11:47:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.185 uVs 11:47:43 Integrated Voltage Measurement... 11:47:52 Voltage Offset Correction: v_off_ini = 716.762 uV, v_off_fin = 714.451 uV 11:47:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.665 uVs 11:47:52 Integrated Voltage Measurement... 11:48:01 Voltage Offset Correction: v_off_ini = 731.772 uV, v_off_fin = 741.176 uV 11:48:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.806 uVs 11:48:01 Integrated Voltage Measurement... 11:48:10 Voltage Offset Correction: v_off_ini = 730.467 uV, v_off_fin = 725.821 uV 11:48:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.241 uVs 11:48:12 I2Y Average and RMS of Measurements VT = -324.505 +- 4.976 uVs I2Y = -29.854 +- 0.458 uTm^2 11:48:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:26 Integrated Voltage Measurement... 11:48:35 Voltage Offset Correction: v_off_ini = 753.780 uV, v_off_fin = 745.360 uV 11:48:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -101.159 uVs 11:48:35 Integrated Voltage Measurement... 11:48:44 Voltage Offset Correction: v_off_ini = 719.606 uV, v_off_fin = 720.462 uV 11:48:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.699 uVs 11:48:44 Integrated Voltage Measurement... 11:48:53 Voltage Offset Correction: v_off_ini = 718.397 uV, v_off_fin = 740.638 uV 11:48:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.448 uVs 11:48:53 Integrated Voltage Measurement... 11:49:02 Voltage Offset Correction: v_off_ini = 735.658 uV, v_off_fin = 745.362 uV 11:49:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.201 uVs 11:49:02 Integrated Voltage Measurement... 11:49:11 Voltage Offset Correction: v_off_ini = 733.639 uV, v_off_fin = 728.475 uV 11:49:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.373 uVs 11:49:11 Integrated Voltage Measurement... 11:49:20 Voltage Offset Correction: v_off_ini = 755.408 uV, v_off_fin = 764.458 uV 11:49:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.364 uVs 11:49:24 I1X Average and RMS of Measurements VT = -99.707 +- 5.007 uVs I1X = 19.943 +- 1.000 uTm 11:49:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:49:31 Integrated Voltage Measurement... 11:49:40 Voltage Offset Correction: v_off_ini = 746.536 uV, v_off_fin = 743.483 uV 11:49:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -237.077 uVs 11:49:40 Integrated Voltage Measurement... 11:49:49 Voltage Offset Correction: v_off_ini = 743.429 uV, v_off_fin = 747.967 uV 11:49:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.126 uVs 11:49:49 Integrated Voltage Measurement... 11:49:58 Voltage Offset Correction: v_off_ini = 735.797 uV, v_off_fin = 733.997 uV 11:49:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.767 uVs 11:49:58 Integrated Voltage Measurement... 11:50:07 Voltage Offset Correction: v_off_ini = 739.335 uV, v_off_fin = 747.601 uV 11:50:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.541 uVs 11:50:07 Integrated Voltage Measurement... 11:50:16 Voltage Offset Correction: v_off_ini = 757.531 uV, v_off_fin = 745.291 uV 11:50:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.193 uVs 11:50:16 Integrated Voltage Measurement... 11:50:25 Voltage Offset Correction: v_off_ini = 760.505 uV, v_off_fin = 759.371 uV 11:50:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.675 uVs 11:50:29 I1Y Average and RMS of Measurements VT = -234.730 +- 1.509 uVs I1Y = -46.947 +- 0.301 uTm 11:50:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:50:37 Integrated Voltage Measurement... 11:50:46 Voltage Offset Correction: v_off_ini = 724.160 uV, v_off_fin = 722.906 uV 11:50:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.586 uVs 11:50:46 Integrated Voltage Measurement... 11:50:55 Voltage Offset Correction: v_off_ini = 707.150 uV, v_off_fin = 720.344 uV 11:50:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.465 uVs 11:50:55 Integrated Voltage Measurement... 11:51:04 Voltage Offset Correction: v_off_ini = 737.365 uV, v_off_fin = 725.566 uV 11:51:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.747 uVs 11:51:04 Integrated Voltage Measurement... 11:51:13 Voltage Offset Correction: v_off_ini = 723.272 uV, v_off_fin = 746.738 uV 11:51:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.537 uVs 11:51:13 Integrated Voltage Measurement... 11:51:22 Voltage Offset Correction: v_off_ini = 712.512 uV, v_off_fin = 735.340 uV 11:51:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.424 uVs 11:51:22 Integrated Voltage Measurement... 11:51:31 Voltage Offset Correction: v_off_ini = 738.836 uV, v_off_fin = 726.427 uV 11:51:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.209 uVs 11:51:34 I2X Average and RMS of Measurements VT = -128.161 +- 6.284 uVs I2X = 11.791 +- 0.578 uTm^2 11:51:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:51:41 Integrated Voltage Measurement... 11:51:50 Voltage Offset Correction: v_off_ini = 737.206 uV, v_off_fin = 760.555 uV 11:51:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.969 uVs 11:51:51 Integrated Voltage Measurement... 11:52:00 Voltage Offset Correction: v_off_ini = 735.141 uV, v_off_fin = 751.464 uV 11:52:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.282 uVs 11:52:00 Integrated Voltage Measurement... 11:52:09 Voltage Offset Correction: v_off_ini = 739.526 uV, v_off_fin = 747.876 uV 11:52:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.729 uVs 11:52:09 Integrated Voltage Measurement... 11:52:18 Voltage Offset Correction: v_off_ini = 745.611 uV, v_off_fin = 750.322 uV 11:52:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.862 uVs 11:52:18 Integrated Voltage Measurement... 11:52:27 Voltage Offset Correction: v_off_ini = 736.542 uV, v_off_fin = 738.393 uV 11:52:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.133 uVs 11:52:27 Integrated Voltage Measurement... 11:52:36 Voltage Offset Correction: v_off_ini = 715.584 uV, v_off_fin = 713.591 uV 11:52:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.608 uVs 11:52:38 I2Y Average and RMS of Measurements VT = -321.597 +- 2.597 uVs I2Y = -29.587 +- 0.239 uTm^2 11:52:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:52:52 Integrated Voltage Measurement... 11:53:01 Voltage Offset Correction: v_off_ini = 731.975 uV, v_off_fin = 738.032 uV 11:53:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.015 uVs 11:53:01 Integrated Voltage Measurement... 11:53:10 Voltage Offset Correction: v_off_ini = 732.391 uV, v_off_fin = 731.029 uV 11:53:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.231 uVs 11:53:10 Integrated Voltage Measurement... 11:53:19 Voltage Offset Correction: v_off_ini = 732.277 uV, v_off_fin = 702.904 uV 11:53:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.614 uVs 11:53:19 Integrated Voltage Measurement... 11:53:28 Voltage Offset Correction: v_off_ini = 703.031 uV, v_off_fin = 699.410 uV 11:53:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 97.801 uVs 11:53:28 Integrated Voltage Measurement... 11:53:37 Voltage Offset Correction: v_off_ini = 711.161 uV, v_off_fin = 705.891 uV 11:53:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -104.214 uVs 11:53:37 Integrated Voltage Measurement... 11:53:46 Voltage Offset Correction: v_off_ini = 683.240 uV, v_off_fin = 685.105 uV 11:53:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.083 uVs 11:53:50 I1X Average and RMS of Measurements VT = -95.326 +- 6.591 uVs I1X = 19.065 +- 1.318 uTm 11:53:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:53:57 Integrated Voltage Measurement... 11:54:06 Voltage Offset Correction: v_off_ini = 711.376 uV, v_off_fin = 693.733 uV 11:54:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -259.045 uVs 11:54:06 Integrated Voltage Measurement... 11:54:15 Voltage Offset Correction: v_off_ini = 688.121 uV, v_off_fin = 690.317 uV 11:54:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.364 uVs 11:54:15 Integrated Voltage Measurement... 11:54:24 Voltage Offset Correction: v_off_ini = 680.944 uV, v_off_fin = 673.175 uV 11:54:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.825 uVs 11:54:24 Integrated Voltage Measurement... 11:54:33 Voltage Offset Correction: v_off_ini = 666.001 uV, v_off_fin = 693.356 uV 11:54:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.164 uVs 11:54:33 Integrated Voltage Measurement... 11:54:42 Voltage Offset Correction: v_off_ini = 692.778 uV, v_off_fin = 683.134 uV 11:54:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.310 uVs 11:54:42 Integrated Voltage Measurement... 11:54:51 Voltage Offset Correction: v_off_ini = 687.181 uV, v_off_fin = 708.535 uV 11:54:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.815 uVs 11:54:55 I1Y Average and RMS of Measurements VT = -248.087 +- 4.666 uVs I1Y = -49.618 +- 0.934 uTm 11:55:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:55:03 Integrated Voltage Measurement... 11:55:12 Voltage Offset Correction: v_off_ini = 694.268 uV, v_off_fin = 681.071 uV 11:55:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.759 uVs 11:55:12 Integrated Voltage Measurement... 11:55:21 Voltage Offset Correction: v_off_ini = 662.701 uV, v_off_fin = 693.140 uV 11:55:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.316 uVs 11:55:21 Integrated Voltage Measurement... 11:55:30 Voltage Offset Correction: v_off_ini = 657.635 uV, v_off_fin = 667.901 uV 11:55:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.065 uVs 11:55:30 Integrated Voltage Measurement... 11:55:39 Voltage Offset Correction: v_off_ini = 688.610 uV, v_off_fin = 694.266 uV 11:55:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.610 uVs 11:55:39 Integrated Voltage Measurement... 11:55:48 Voltage Offset Correction: v_off_ini = 696.464 uV, v_off_fin = 674.458 uV 11:55:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.274 uVs 11:55:48 Integrated Voltage Measurement... 11:55:57 Voltage Offset Correction: v_off_ini = 696.260 uV, v_off_fin = 692.444 uV 11:55:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.806 uVs 11:56:00 I2X Average and RMS of Measurements VT = -120.638 +- 3.212 uVs I2X = 11.099 +- 0.295 uTm^2 11:56:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:56:07 Integrated Voltage Measurement... 11:56:16 Voltage Offset Correction: v_off_ini = 698.728 uV, v_off_fin = 695.350 uV 11:56:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.871 uVs 11:56:17 Integrated Voltage Measurement... 11:56:26 Voltage Offset Correction: v_off_ini = 700.808 uV, v_off_fin = 701.413 uV 11:56:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.244 uVs 11:56:26 Integrated Voltage Measurement... 11:56:35 Voltage Offset Correction: v_off_ini = 696.464 uV, v_off_fin = 692.766 uV 11:56:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.638 uVs 11:56:35 Integrated Voltage Measurement... 11:56:44 Voltage Offset Correction: v_off_ini = 687.250 uV, v_off_fin = 686.199 uV 11:56:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.331 uVs 11:56:44 Integrated Voltage Measurement... 11:56:53 Voltage Offset Correction: v_off_ini = 689.252 uV, v_off_fin = 703.034 uV 11:56:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.315 uVs 11:56:53 Integrated Voltage Measurement... 11:57:02 Voltage Offset Correction: v_off_ini = 702.464 uV, v_off_fin = 706.733 uV 11:57:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.455 uVs 11:57:04 I2Y Average and RMS of Measurements VT = -316.142 +- 10.702 uVs I2Y = -29.085 +- 0.985 uTm^2 11:57:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:57:18 Integrated Voltage Measurement... 11:57:27 Voltage Offset Correction: v_off_ini = 731.160 uV, v_off_fin = 735.860 uV 11:57:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -120.992 uVs 11:57:27 Integrated Voltage Measurement... 11:57:36 Voltage Offset Correction: v_off_ini = 709.836 uV, v_off_fin = 714.513 uV 11:57:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.611 uVs 11:57:36 Integrated Voltage Measurement... 11:57:45 Voltage Offset Correction: v_off_ini = 714.422 uV, v_off_fin = 711.852 uV 11:57:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.815 uVs 11:57:45 Integrated Voltage Measurement... 11:57:54 Voltage Offset Correction: v_off_ini = 714.138 uV, v_off_fin = 717.111 uV 11:57:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.194 uVs 11:57:54 Integrated Voltage Measurement... 11:58:03 Voltage Offset Correction: v_off_ini = 718.281 uV, v_off_fin = 710.474 uV 11:58:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.843 uVs 11:58:03 Integrated Voltage Measurement... 11:58:12 Voltage Offset Correction: v_off_ini = 703.286 uV, v_off_fin = 722.717 uV 11:58:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.061 uVs 11:58:16 I1X Average and RMS of Measurements VT = -105.586 +- 4.370 uVs I1X = 21.118 +- 0.874 uTm 11:58:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:58:23 Integrated Voltage Measurement... 11:58:32 Voltage Offset Correction: v_off_ini = 721.951 uV, v_off_fin = 704.351 uV 11:58:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.436 uVs 11:58:32 Integrated Voltage Measurement... 11:58:41 Voltage Offset Correction: v_off_ini = 720.149 uV, v_off_fin = 736.498 uV 11:58:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.420 uVs 11:58:41 Integrated Voltage Measurement... 11:58:50 Voltage Offset Correction: v_off_ini = 734.215 uV, v_off_fin = 738.510 uV 11:58:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.684 uVs 11:58:50 Integrated Voltage Measurement... 11:58:59 Voltage Offset Correction: v_off_ini = 752.483 uV, v_off_fin = 749.528 uV 11:58:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.877 uVs 11:58:59 Integrated Voltage Measurement... 11:59:08 Voltage Offset Correction: v_off_ini = 744.252 uV, v_off_fin = 736.635 uV 11:59:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.788 uVs 11:59:08 Integrated Voltage Measurement... 11:59:17 Voltage Offset Correction: v_off_ini = 761.930 uV, v_off_fin = 755.120 uV 11:59:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.225 uVs 11:59:21 I1Y Average and RMS of Measurements VT = -239.738 +- 8.917 uVs I1Y = -47.948 +- 1.783 uTm 11:59:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:59:29 Integrated Voltage Measurement... 11:59:38 Voltage Offset Correction: v_off_ini = 749.821 uV, v_off_fin = 729.646 uV 11:59:38 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -113.391 uVs 11:59:38 Integrated Voltage Measurement... 11:59:47 Voltage Offset Correction: v_off_ini = 741.113 uV, v_off_fin = 748.920 uV 11:59:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.852 uVs 11:59:47 Integrated Voltage Measurement... 11:59:56 Voltage Offset Correction: v_off_ini = 758.687 uV, v_off_fin = 733.849 uV 11:59:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.534 uVs 11:59:56 Integrated Voltage Measurement... 12:00:05 Voltage Offset Correction: v_off_ini = 770.020 uV, v_off_fin = 751.989 uV 12:00:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.269 uVs 12:00:05 Integrated Voltage Measurement... 12:00:14 Voltage Offset Correction: v_off_ini = 755.872 uV, v_off_fin = 726.724 uV 12:00:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.980 uVs 12:00:14 Integrated Voltage Measurement... 12:00:23 Voltage Offset Correction: v_off_ini = 730.066 uV, v_off_fin = 743.864 uV 12:00:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.371 uVs 12:00:26 I2X Average and RMS of Measurements VT = -127.066 +- 14.652 uVs I2X = 11.690 +- 1.348 uTm^2 12:00:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:00:33 Integrated Voltage Measurement... 12:00:42 Voltage Offset Correction: v_off_ini = 733.405 uV, v_off_fin = 746.711 uV 12:00:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.315 uVs 12:00:42 Integrated Voltage Measurement... 12:00:51 Voltage Offset Correction: v_off_ini = 734.161 uV, v_off_fin = 735.819 uV 12:00:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.828 uVs 12:00:52 Integrated Voltage Measurement... 12:01:00 Voltage Offset Correction: v_off_ini = 737.371 uV, v_off_fin = 740.898 uV 12:01:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.950 uVs 12:01:01 Integrated Voltage Measurement... 12:01:10 Voltage Offset Correction: v_off_ini = 734.406 uV, v_off_fin = 726.443 uV 12:01:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.530 uVs 12:01:10 Integrated Voltage Measurement... 12:01:19 Voltage Offset Correction: v_off_ini = 716.848 uV, v_off_fin = 706.383 uV 12:01:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.168 uVs 12:01:19 Integrated Voltage Measurement... 12:01:28 Voltage Offset Correction: v_off_ini = 720.382 uV, v_off_fin = 724.964 uV 12:01:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.522 uVs 12:01:30 I2Y Average and RMS of Measurements VT = -304.552 +- 8.413 uVs I2Y = -28.019 +- 0.774 uTm^2 12:01:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:01:51 Integrated Voltage Measurement... 12:02:00 Voltage Offset Correction: v_off_ini = 737.734 uV, v_off_fin = 723.998 uV 12:02:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -109.603 uVs 12:02:00 Integrated Voltage Measurement... 12:02:09 Voltage Offset Correction: v_off_ini = 751.274 uV, v_off_fin = 750.087 uV 12:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.835 uVs 12:02:09 Integrated Voltage Measurement... 12:02:18 Voltage Offset Correction: v_off_ini = 756.698 uV, v_off_fin = 760.237 uV 12:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.559 uVs 12:02:18 Integrated Voltage Measurement... 12:02:27 Voltage Offset Correction: v_off_ini = 748.235 uV, v_off_fin = 756.377 uV 12:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.879 uVs 12:02:27 Integrated Voltage Measurement... 12:02:36 Voltage Offset Correction: v_off_ini = 757.909 uV, v_off_fin = 748.419 uV 12:02:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.462 uVs 12:02:36 Integrated Voltage Measurement... 12:02:45 Voltage Offset Correction: v_off_ini = 746.046 uV, v_off_fin = 758.795 uV 12:02:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.025 uVs 12:02:49 I1X Average and RMS of Measurements VT = -101.060 +- 4.875 uVs I1X = 20.213 +- 0.976 uTm 12:02:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:02:56 Integrated Voltage Measurement... 12:03:05 Voltage Offset Correction: v_off_ini = 752.015 uV, v_off_fin = 762.235 uV 12:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -242.587 uVs 12:03:05 Integrated Voltage Measurement... 12:03:14 Voltage Offset Correction: v_off_ini = 769.772 uV, v_off_fin = 789.465 uV 12:03:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.155 uVs 12:03:14 Integrated Voltage Measurement... 12:03:23 Voltage Offset Correction: v_off_ini = 781.405 uV, v_off_fin = 772.989 uV 12:03:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.708 uVs 12:03:23 Integrated Voltage Measurement... 12:03:32 Voltage Offset Correction: v_off_ini = 769.576 uV, v_off_fin = 780.811 uV 12:03:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.598 uVs 12:03:32 Integrated Voltage Measurement... 12:03:41 Voltage Offset Correction: v_off_ini = 792.293 uV, v_off_fin = 771.435 uV 12:03:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.346 uVs 12:03:41 Integrated Voltage Measurement... 12:03:50 Voltage Offset Correction: v_off_ini = 779.887 uV, v_off_fin = 795.612 uV 12:03:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.139 uVs 12:03:54 I1Y Average and RMS of Measurements VT = -242.589 +- 4.345 uVs I1Y = -48.519 +- 0.869 uTm 12:03:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:04:02 Integrated Voltage Measurement... 12:04:11 Voltage Offset Correction: v_off_ini = 784.826 uV, v_off_fin = 770.967 uV 12:04:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -113.174 uVs 12:04:11 Integrated Voltage Measurement... 12:04:20 Voltage Offset Correction: v_off_ini = 770.002 uV, v_off_fin = 794.456 uV 12:04:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.984 uVs 12:04:20 Integrated Voltage Measurement... 12:04:29 Voltage Offset Correction: v_off_ini = 773.710 uV, v_off_fin = 762.097 uV 12:04:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.825 uVs 12:04:29 Integrated Voltage Measurement... 12:04:38 Voltage Offset Correction: v_off_ini = 771.553 uV, v_off_fin = 783.744 uV 12:04:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.636 uVs 12:04:38 Integrated Voltage Measurement... 12:04:47 Voltage Offset Correction: v_off_ini = 790.516 uV, v_off_fin = 791.175 uV 12:04:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.220 uVs 12:04:47 Integrated Voltage Measurement... 12:04:56 Voltage Offset Correction: v_off_ini = 790.716 uV, v_off_fin = 794.662 uV 12:04:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.604 uVs 12:04:58 I2X Average and RMS of Measurements VT = -114.907 +- 3.840 uVs I2X = 10.571 +- 0.353 uTm^2 12:05:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:05:06 Integrated Voltage Measurement... 12:05:15 Voltage Offset Correction: v_off_ini = 773.430 uV, v_off_fin = 778.520 uV 12:05:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.861 uVs 12:05:15 Integrated Voltage Measurement... 12:05:24 Voltage Offset Correction: v_off_ini = 785.406 uV, v_off_fin = 777.488 uV 12:05:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.195 uVs 12:05:24 Integrated Voltage Measurement... 12:05:33 Voltage Offset Correction: v_off_ini = 787.987 uV, v_off_fin = 787.261 uV 12:05:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.924 uVs 12:05:33 Integrated Voltage Measurement... 12:05:42 Voltage Offset Correction: v_off_ini = 784.651 uV, v_off_fin = 785.104 uV 12:05:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.077 uVs 12:05:42 Integrated Voltage Measurement... 12:05:51 Voltage Offset Correction: v_off_ini = 776.874 uV, v_off_fin = 774.503 uV 12:05:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.829 uVs 12:05:51 Integrated Voltage Measurement... 12:06:00 Voltage Offset Correction: v_off_ini = 783.827 uV, v_off_fin = 797.196 uV 12:06:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.274 uVs 12:06:03 I2Y Average and RMS of Measurements VT = -314.193 +- 9.151 uVs I2Y = -28.906 +- 0.842 uTm^2 12:06:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:06:17 Integrated Voltage Measurement... 12:06:26 Voltage Offset Correction: v_off_ini = 785.089 uV, v_off_fin = 784.878 uV 12:06:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.906 uVs 12:06:26 Integrated Voltage Measurement... 12:06:35 Voltage Offset Correction: v_off_ini = 804.245 uV, v_off_fin = 780.535 uV 12:06:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.200 uVs 12:06:35 Integrated Voltage Measurement... 12:06:44 Voltage Offset Correction: v_off_ini = 784.958 uV, v_off_fin = 797.494 uV 12:06:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.624 uVs 12:06:44 Integrated Voltage Measurement... 12:06:53 Voltage Offset Correction: v_off_ini = 798.559 uV, v_off_fin = 787.055 uV 12:06:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.249 uVs 12:06:53 Integrated Voltage Measurement... 12:07:02 Voltage Offset Correction: v_off_ini = 786.865 uV, v_off_fin = 775.060 uV 12:07:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.695 uVs 12:07:02 Integrated Voltage Measurement... 12:07:11 Voltage Offset Correction: v_off_ini = 789.311 uV, v_off_fin = 786.504 uV 12:07:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 59.506 uVs 12:07:15 I1X Average and RMS of Measurements VT = -86.530 +- 10.639 uVs I1X = 17.306 +- 2.128 uTm 12:07:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:22 Integrated Voltage Measurement... 12:07:31 Voltage Offset Correction: v_off_ini = 760.197 uV, v_off_fin = 770.885 uV 12:07:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.808 uVs 12:07:31 Integrated Voltage Measurement... 12:07:40 Voltage Offset Correction: v_off_ini = 767.812 uV, v_off_fin = 776.891 uV 12:07:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.573 uVs 12:07:40 Integrated Voltage Measurement... 12:07:49 Voltage Offset Correction: v_off_ini = 779.773 uV, v_off_fin = 766.572 uV 12:07:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.813 uVs 12:07:49 Integrated Voltage Measurement... 12:07:58 Voltage Offset Correction: v_off_ini = 763.500 uV, v_off_fin = 771.516 uV 12:07:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 240.767 uVs 12:07:58 Integrated Voltage Measurement... 12:08:07 Voltage Offset Correction: v_off_ini = 765.511 uV, v_off_fin = 758.830 uV 12:08:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -249.219 uVs 12:08:07 Integrated Voltage Measurement... 12:08:16 Voltage Offset Correction: v_off_ini = 763.809 uV, v_off_fin = 771.893 uV 12:08:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.086 uVs 12:08:20 I1Y Average and RMS of Measurements VT = -235.711 +- 8.152 uVs I1Y = -47.141 +- 1.629 uTm 12:08:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:08:28 Integrated Voltage Measurement... 12:08:37 Voltage Offset Correction: v_off_ini = 754.145 uV, v_off_fin = 754.174 uV 12:08:37 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -114.388 uVs 12:08:37 Integrated Voltage Measurement... 12:08:46 Voltage Offset Correction: v_off_ini = 770.474 uV, v_off_fin = 772.218 uV 12:08:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.060 uVs 12:08:46 Integrated Voltage Measurement... 12:08:55 Voltage Offset Correction: v_off_ini = 749.671 uV, v_off_fin = 734.760 uV 12:08:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.401 uVs 12:08:55 Integrated Voltage Measurement... 12:09:04 Voltage Offset Correction: v_off_ini = 747.890 uV, v_off_fin = 773.553 uV 12:09:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.543 uVs 12:09:04 Integrated Voltage Measurement... 12:09:13 Voltage Offset Correction: v_off_ini = 758.926 uV, v_off_fin = 765.132 uV 12:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.307 uVs 12:09:13 Integrated Voltage Measurement... 12:09:22 Voltage Offset Correction: v_off_ini = 761.489 uV, v_off_fin = 771.615 uV 12:09:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.997 uVs 12:09:24 I2X Average and RMS of Measurements VT = -117.449 +- 9.588 uVs I2X = 10.805 +- 0.883 uTm^2 12:09:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:32 Integrated Voltage Measurement... 12:09:41 Voltage Offset Correction: v_off_ini = 767.250 uV, v_off_fin = 754.514 uV 12:09:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.470 uVs 12:09:41 Integrated Voltage Measurement... 12:09:50 Voltage Offset Correction: v_off_ini = 768.278 uV, v_off_fin = 746.159 uV 12:09:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.998 uVs 12:09:50 Integrated Voltage Measurement... 12:09:59 Voltage Offset Correction: v_off_ini = 773.769 uV, v_off_fin = 778.837 uV 12:09:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.404 uVs 12:09:59 Integrated Voltage Measurement... 12:10:08 Voltage Offset Correction: v_off_ini = 765.670 uV, v_off_fin = 770.293 uV 12:10:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.187 uVs 12:10:08 Integrated Voltage Measurement... 12:10:17 Voltage Offset Correction: v_off_ini = 788.655 uV, v_off_fin = 784.267 uV 12:10:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.338 uVs 12:10:17 Integrated Voltage Measurement... 12:10:26 Voltage Offset Correction: v_off_ini = 789.645 uV, v_off_fin = 768.500 uV 12:10:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.742 uVs 12:10:29 I2Y Average and RMS of Measurements VT = -307.190 +- 6.063 uVs I2Y = -28.261 +- 0.558 uTm^2 12:10:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:10:44 Integrated Voltage Measurement... 12:10:53 Voltage Offset Correction: v_off_ini = 770.086 uV, v_off_fin = 755.793 uV 12:10:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -103.298 uVs 12:10:53 Integrated Voltage Measurement... 12:11:02 Voltage Offset Correction: v_off_ini = 761.003 uV, v_off_fin = 726.354 uV 12:11:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.910 uVs 12:11:02 Integrated Voltage Measurement... 12:11:11 Voltage Offset Correction: v_off_ini = 726.715 uV, v_off_fin = 754.406 uV 12:11:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.500 uVs 12:11:11 Integrated Voltage Measurement... 12:11:20 Voltage Offset Correction: v_off_ini = 751.562 uV, v_off_fin = 746.826 uV 12:11:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.515 uVs 12:11:20 Integrated Voltage Measurement... 12:11:29 Voltage Offset Correction: v_off_ini = 735.862 uV, v_off_fin = 729.214 uV 12:11:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.426 uVs 12:11:29 Integrated Voltage Measurement... 12:11:38 Voltage Offset Correction: v_off_ini = 732.815 uV, v_off_fin = 758.636 uV 12:11:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.655 uVs 12:11:42 I1X Average and RMS of Measurements VT = -92.050 +- 5.539 uVs I1X = 18.411 +- 1.108 uTm 12:11:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:11:49 Integrated Voltage Measurement... 12:11:58 Voltage Offset Correction: v_off_ini = 763.034 uV, v_off_fin = 750.431 uV 12:11:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -232.365 uVs 12:11:58 Integrated Voltage Measurement... 12:12:07 Voltage Offset Correction: v_off_ini = 770.696 uV, v_off_fin = 781.610 uV 12:12:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.427 uVs 12:12:07 Integrated Voltage Measurement... 12:12:16 Voltage Offset Correction: v_off_ini = 759.238 uV, v_off_fin = 757.358 uV 12:12:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.535 uVs 12:12:16 Integrated Voltage Measurement... 12:12:25 Voltage Offset Correction: v_off_ini = 768.711 uV, v_off_fin = 769.433 uV 12:12:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 232.900 uVs 12:12:25 Integrated Voltage Measurement... 12:12:34 Voltage Offset Correction: v_off_ini = 757.583 uV, v_off_fin = 739.613 uV 12:12:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -255.709 uVs 12:12:34 Integrated Voltage Measurement... 12:12:43 Voltage Offset Correction: v_off_ini = 747.117 uV, v_off_fin = 750.909 uV 12:12:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.928 uVs 12:12:47 I1Y Average and RMS of Measurements VT = -235.978 +- 5.470 uVs I1Y = -47.195 +- 1.094 uTm 12:12:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:12:55 Integrated Voltage Measurement... 12:13:04 Voltage Offset Correction: v_off_ini = 733.163 uV, v_off_fin = 756.692 uV 12:13:04 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -107.047 uVs 12:13:04 Integrated Voltage Measurement... 12:13:13 Voltage Offset Correction: v_off_ini = 761.800 uV, v_off_fin = 758.182 uV 12:13:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.214 uVs 12:13:13 Integrated Voltage Measurement... 12:13:22 Voltage Offset Correction: v_off_ini = 777.810 uV, v_off_fin = 754.629 uV 12:13:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.931 uVs 12:13:22 Integrated Voltage Measurement... 12:13:31 Voltage Offset Correction: v_off_ini = 760.256 uV, v_off_fin = 739.543 uV 12:13:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.953 uVs 12:13:31 Integrated Voltage Measurement... 12:13:40 Voltage Offset Correction: v_off_ini = 756.951 uV, v_off_fin = 756.448 uV 12:13:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.271 uVs 12:13:40 Integrated Voltage Measurement... 12:13:49 Voltage Offset Correction: v_off_ini = 748.090 uV, v_off_fin = 763.502 uV 12:13:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.494 uVs 12:13:52 I2X Average and RMS of Measurements VT = -107.152 +- 5.475 uVs I2X = 9.858 +- 0.504 uTm^2 12:13:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:13:59 Integrated Voltage Measurement... 12:14:08 Voltage Offset Correction: v_off_ini = 749.752 uV, v_off_fin = 744.660 uV 12:14:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.571 uVs 12:14:08 Integrated Voltage Measurement... 12:14:17 Voltage Offset Correction: v_off_ini = 754.019 uV, v_off_fin = 758.676 uV 12:14:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.250 uVs 12:14:17 Integrated Voltage Measurement... 12:14:26 Voltage Offset Correction: v_off_ini = 750.329 uV, v_off_fin = 756.231 uV 12:14:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.438 uVs 12:14:26 Integrated Voltage Measurement... 12:14:35 Voltage Offset Correction: v_off_ini = 769.404 uV, v_off_fin = 778.955 uV 12:14:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.613 uVs 12:14:35 Integrated Voltage Measurement... 12:14:44 Voltage Offset Correction: v_off_ini = 752.217 uV, v_off_fin = 740.383 uV 12:14:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.592 uVs 12:14:45 Integrated Voltage Measurement... 12:14:54 Voltage Offset Correction: v_off_ini = 745.624 uV, v_off_fin = 741.347 uV 12:14:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.686 uVs 12:14:56 I2Y Average and RMS of Measurements VT = -301.358 +- 11.771 uVs I2Y = -27.725 +- 1.083 uTm^2 12:15:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:15:11 Integrated Voltage Measurement... 12:15:20 Voltage Offset Correction: v_off_ini = 740.525 uV, v_off_fin = 726.691 uV 12:15:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.307 uVs 12:15:20 Integrated Voltage Measurement... 12:15:29 Voltage Offset Correction: v_off_ini = 732.999 uV, v_off_fin = 737.531 uV 12:15:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.829 uVs 12:15:29 Integrated Voltage Measurement... 12:15:38 Voltage Offset Correction: v_off_ini = 752.640 uV, v_off_fin = 742.492 uV 12:15:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.240 uVs 12:15:38 Integrated Voltage Measurement... 12:15:47 Voltage Offset Correction: v_off_ini = 759.114 uV, v_off_fin = 757.296 uV 12:15:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.488 uVs 12:15:47 Integrated Voltage Measurement... 12:15:56 Voltage Offset Correction: v_off_ini = 740.185 uV, v_off_fin = 734.912 uV 12:15:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.756 uVs 12:15:56 Integrated Voltage Measurement... 12:16:05 Voltage Offset Correction: v_off_ini = 752.763 uV, v_off_fin = 761.821 uV 12:16:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.342 uVs 12:16:09 I1X Average and RMS of Measurements VT = -102.994 +- 5.930 uVs I1X = 20.599 +- 1.186 uTm 12:16:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:16:16 Integrated Voltage Measurement... 12:16:25 Voltage Offset Correction: v_off_ini = 757.408 uV, v_off_fin = 751.767 uV 12:16:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.605 uVs 12:16:25 Integrated Voltage Measurement... 12:16:34 Voltage Offset Correction: v_off_ini = 746.850 uV, v_off_fin = 765.530 uV 12:16:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.070 uVs 12:16:34 Integrated Voltage Measurement... 12:16:43 Voltage Offset Correction: v_off_ini = 748.760 uV, v_off_fin = 745.025 uV 12:16:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.783 uVs 12:16:43 Integrated Voltage Measurement... 12:16:52 Voltage Offset Correction: v_off_ini = 755.637 uV, v_off_fin = 774.514 uV 12:16:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.950 uVs 12:16:52 Integrated Voltage Measurement... 12:17:01 Voltage Offset Correction: v_off_ini = 763.808 uV, v_off_fin = 755.969 uV 12:17:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.165 uVs 12:17:01 Integrated Voltage Measurement... 12:17:10 Voltage Offset Correction: v_off_ini = 775.123 uV, v_off_fin = 773.302 uV 12:17:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.389 uVs 12:17:14 I1Y Average and RMS of Measurements VT = -234.160 +- 1.679 uVs I1Y = -46.832 +- 0.336 uTm 12:17:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:17:22 Integrated Voltage Measurement... 12:17:31 Voltage Offset Correction: v_off_ini = 765.764 uV, v_off_fin = 765.383 uV 12:17:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.117 uVs 12:17:31 Integrated Voltage Measurement... 12:17:40 Voltage Offset Correction: v_off_ini = 760.086 uV, v_off_fin = 741.617 uV 12:17:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.156 uVs 12:17:40 Integrated Voltage Measurement... 12:17:49 Voltage Offset Correction: v_off_ini = 760.032 uV, v_off_fin = 737.537 uV 12:17:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -110.786 uVs 12:17:49 Integrated Voltage Measurement... 12:17:58 Voltage Offset Correction: v_off_ini = 752.513 uV, v_off_fin = 765.436 uV 12:17:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 125.943 uVs 12:17:58 Integrated Voltage Measurement... 12:18:07 Voltage Offset Correction: v_off_ini = 764.430 uV, v_off_fin = 763.606 uV 12:18:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -118.789 uVs 12:18:07 Integrated Voltage Measurement... 12:18:16 Voltage Offset Correction: v_off_ini = 780.200 uV, v_off_fin = 791.140 uV 12:18:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.938 uVs 12:18:19 I2X Average and RMS of Measurements VT = -121.121 +- 2.073 uVs I2X = 11.144 +- 0.190 uTm^2 12:18:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:18:26 Integrated Voltage Measurement... 12:18:35 Voltage Offset Correction: v_off_ini = 774.206 uV, v_off_fin = 780.872 uV 12:18:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.778 uVs 12:18:36 Integrated Voltage Measurement... 12:18:45 Voltage Offset Correction: v_off_ini = 762.539 uV, v_off_fin = 762.228 uV 12:18:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.470 uVs 12:18:45 Integrated Voltage Measurement... 12:18:54 Voltage Offset Correction: v_off_ini = 764.525 uV, v_off_fin = 773.384 uV 12:18:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.753 uVs 12:18:54 Integrated Voltage Measurement... 12:19:03 Voltage Offset Correction: v_off_ini = 770.873 uV, v_off_fin = 763.160 uV 12:19:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.704 uVs 12:19:03 Integrated Voltage Measurement... 12:19:12 Voltage Offset Correction: v_off_ini = 747.810 uV, v_off_fin = 762.811 uV 12:19:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.301 uVs 12:19:12 Integrated Voltage Measurement... 12:19:21 Voltage Offset Correction: v_off_ini = 752.695 uV, v_off_fin = 737.539 uV 12:19:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 317.908 uVs 12:19:23 I2Y Average and RMS of Measurements VT = -309.486 +- 1.533 uVs I2Y = -28.473 +- 0.141 uTm^2 12:19:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:19:38 Integrated Voltage Measurement... 12:19:47 Voltage Offset Correction: v_off_ini = 726.179 uV, v_off_fin = 722.253 uV 12:19:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -109.285 uVs 12:19:47 Integrated Voltage Measurement... 12:19:56 Voltage Offset Correction: v_off_ini = 747.132 uV, v_off_fin = 731.261 uV 12:19:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.683 uVs 12:19:56 Integrated Voltage Measurement... 12:20:05 Voltage Offset Correction: v_off_ini = 730.204 uV, v_off_fin = 731.505 uV 12:20:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.980 uVs 12:20:05 Integrated Voltage Measurement... 12:20:14 Voltage Offset Correction: v_off_ini = 731.825 uV, v_off_fin = 728.262 uV 12:20:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.996 uVs 12:20:14 Integrated Voltage Measurement... 12:20:23 Voltage Offset Correction: v_off_ini = 731.286 uV, v_off_fin = 712.928 uV 12:20:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.767 uVs 12:20:23 Integrated Voltage Measurement... 12:20:32 Voltage Offset Correction: v_off_ini = 720.850 uV, v_off_fin = 693.258 uV 12:20:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.759 uVs 12:20:37 I1X Average and RMS of Measurements VT = -92.912 +- 8.756 uVs I1X = 18.583 +- 1.752 uTm 12:20:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:20:43 Integrated Voltage Measurement... 12:20:52 Voltage Offset Correction: v_off_ini = 715.782 uV, v_off_fin = 712.563 uV 12:20:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -251.459 uVs 12:20:52 Integrated Voltage Measurement... 12:21:01 Voltage Offset Correction: v_off_ini = 694.894 uV, v_off_fin = 722.183 uV 12:21:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.753 uVs 12:21:01 Integrated Voltage Measurement... 12:21:10 Voltage Offset Correction: v_off_ini = 708.699 uV, v_off_fin = 699.716 uV 12:21:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.470 uVs 12:21:10 Integrated Voltage Measurement... 12:21:19 Voltage Offset Correction: v_off_ini = 722.335 uV, v_off_fin = 727.422 uV 12:21:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.941 uVs 12:21:19 Integrated Voltage Measurement... 12:21:28 Voltage Offset Correction: v_off_ini = 700.390 uV, v_off_fin = 703.651 uV 12:21:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.067 uVs 12:21:28 Integrated Voltage Measurement... 12:21:37 Voltage Offset Correction: v_off_ini = 718.945 uV, v_off_fin = 731.031 uV 12:21:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.974 uVs 12:21:42 I1Y Average and RMS of Measurements VT = -245.777 +- 4.113 uVs I1Y = -49.156 +- 0.822 uTm 12:21:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:21:49 Integrated Voltage Measurement... 12:21:58 Voltage Offset Correction: v_off_ini = 715.954 uV, v_off_fin = 717.963 uV 12:21:58 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -105.187 uVs 12:21:58 Integrated Voltage Measurement... 12:22:07 Voltage Offset Correction: v_off_ini = 726.147 uV, v_off_fin = 740.633 uV 12:22:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.542 uVs 12:22:07 Integrated Voltage Measurement... 12:22:16 Voltage Offset Correction: v_off_ini = 725.001 uV, v_off_fin = 715.590 uV 12:22:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.177 uVs 12:22:16 Integrated Voltage Measurement... 12:22:25 Voltage Offset Correction: v_off_ini = 720.368 uV, v_off_fin = 734.040 uV 12:22:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.868 uVs 12:22:26 Integrated Voltage Measurement... 12:22:35 Voltage Offset Correction: v_off_ini = 737.524 uV, v_off_fin = 718.637 uV 12:22:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.719 uVs 12:22:35 Integrated Voltage Measurement... 12:22:44 Voltage Offset Correction: v_off_ini = 713.286 uV, v_off_fin = 735.138 uV 12:22:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 105.398 uVs 12:22:46 I2X Average and RMS of Measurements VT = -105.315 +- 7.943 uVs I2X = 9.689 +- 0.731 uTm^2 12:22:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:22:54 Integrated Voltage Measurement... 12:23:03 Voltage Offset Correction: v_off_ini = 716.072 uV, v_off_fin = 721.690 uV 12:23:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.132 uVs 12:23:03 Integrated Voltage Measurement... 12:23:12 Voltage Offset Correction: v_off_ini = 724.020 uV, v_off_fin = 703.327 uV 12:23:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.200 uVs 12:23:12 Integrated Voltage Measurement... 12:23:21 Voltage Offset Correction: v_off_ini = 684.146 uV, v_off_fin = 715.830 uV 12:23:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.537 uVs 12:23:21 Integrated Voltage Measurement... 12:23:30 Voltage Offset Correction: v_off_ini = 729.015 uV, v_off_fin = 730.470 uV 12:23:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 302.757 uVs 12:23:30 Integrated Voltage Measurement... 12:23:39 Voltage Offset Correction: v_off_ini = 720.175 uV, v_off_fin = 721.401 uV 12:23:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.785 uVs 12:23:39 Integrated Voltage Measurement... 12:23:48 Voltage Offset Correction: v_off_ini = 721.684 uV, v_off_fin = 718.714 uV 12:23:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.458 uVs 12:23:50 I2Y Average and RMS of Measurements VT = -301.812 +- 6.186 uVs I2Y = -27.767 +- 0.570 uTm^2 12:24:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:24:12 Integrated Voltage Measurement... 12:24:21 Voltage Offset Correction: v_off_ini = 724.959 uV, v_off_fin = 705.992 uV 12:24:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.117 uVs 12:24:21 Integrated Voltage Measurement... 12:24:30 Voltage Offset Correction: v_off_ini = 706.381 uV, v_off_fin = 694.247 uV 12:24:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.369 uVs 12:24:30 Integrated Voltage Measurement... 12:24:39 Voltage Offset Correction: v_off_ini = 720.170 uV, v_off_fin = 710.619 uV 12:24:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.711 uVs 12:24:39 Integrated Voltage Measurement... 12:24:48 Voltage Offset Correction: v_off_ini = 702.160 uV, v_off_fin = 710.332 uV 12:24:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.973 uVs 12:24:48 Integrated Voltage Measurement... 12:24:57 Voltage Offset Correction: v_off_ini = 721.978 uV, v_off_fin = 715.144 uV 12:24:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.142 uVs 12:24:57 Integrated Voltage Measurement... 12:25:06 Voltage Offset Correction: v_off_ini = 717.669 uV, v_off_fin = 712.095 uV 12:25:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.582 uVs 12:25:10 I1X Average and RMS of Measurements VT = -92.316 +- 3.930 uVs I1X = 18.464 +- 0.786 uTm 12:25:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:25:17 Integrated Voltage Measurement... 12:25:26 Voltage Offset Correction: v_off_ini = 714.932 uV, v_off_fin = 713.416 uV 12:25:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -242.183 uVs 12:25:26 Integrated Voltage Measurement... 12:25:35 Voltage Offset Correction: v_off_ini = 709.129 uV, v_off_fin = 723.284 uV 12:25:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.476 uVs 12:25:35 Integrated Voltage Measurement... 12:25:44 Voltage Offset Correction: v_off_ini = 722.556 uV, v_off_fin = 703.477 uV 12:25:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.329 uVs 12:25:44 Integrated Voltage Measurement... 12:25:53 Voltage Offset Correction: v_off_ini = 732.801 uV, v_off_fin = 733.859 uV 12:25:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.299 uVs 12:25:53 Integrated Voltage Measurement... 12:26:02 Voltage Offset Correction: v_off_ini = 720.704 uV, v_off_fin = 715.689 uV 12:26:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.596 uVs 12:26:02 Integrated Voltage Measurement... 12:26:11 Voltage Offset Correction: v_off_ini = 700.172 uV, v_off_fin = 739.699 uV 12:26:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 268.769 uVs 12:26:15 I1Y Average and RMS of Measurements VT = -243.942 +- 11.219 uVs I1Y = -48.788 +- 2.242 uTm 12:26:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:26:23 Integrated Voltage Measurement... 12:26:32 Voltage Offset Correction: v_off_ini = 730.467 uV, v_off_fin = 727.160 uV 12:26:32 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -91.811 uVs 12:26:32 Integrated Voltage Measurement... 12:26:41 Voltage Offset Correction: v_off_ini = 726.896 uV, v_off_fin = 732.911 uV 12:26:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.204 uVs 12:26:41 Integrated Voltage Measurement... 12:26:50 Voltage Offset Correction: v_off_ini = 735.681 uV, v_off_fin = 722.572 uV 12:26:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -125.871 uVs 12:26:50 Integrated Voltage Measurement... 12:26:59 Voltage Offset Correction: v_off_ini = 739.812 uV, v_off_fin = 743.285 uV 12:26:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.902 uVs 12:26:59 Integrated Voltage Measurement... 12:27:08 Voltage Offset Correction: v_off_ini = 723.058 uV, v_off_fin = 722.995 uV 12:27:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.964 uVs 12:27:08 Integrated Voltage Measurement... 12:27:17 Voltage Offset Correction: v_off_ini = 744.998 uV, v_off_fin = 758.655 uV 12:27:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.719 uVs 12:27:20 I2X Average and RMS of Measurements VT = -103.245 +- 9.545 uVs I2X = 9.499 +- 0.879 uTm^2 12:27:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:27:28 Integrated Voltage Measurement... 12:27:37 Voltage Offset Correction: v_off_ini = 754.849 uV, v_off_fin = 749.547 uV 12:27:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.914 uVs 12:27:37 Integrated Voltage Measurement... 12:27:46 Voltage Offset Correction: v_off_ini = 729.899 uV, v_off_fin = 745.029 uV 12:27:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.951 uVs 12:27:46 Integrated Voltage Measurement... 12:27:55 Voltage Offset Correction: v_off_ini = 726.070 uV, v_off_fin = 731.123 uV 12:27:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.226 uVs 12:27:55 Integrated Voltage Measurement... 12:28:04 Voltage Offset Correction: v_off_ini = 708.071 uV, v_off_fin = 735.241 uV 12:28:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.905 uVs 12:28:04 Integrated Voltage Measurement... 12:28:13 Voltage Offset Correction: v_off_ini = 720.296 uV, v_off_fin = 742.327 uV 12:28:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.886 uVs 12:28:13 Integrated Voltage Measurement... 12:28:22 Voltage Offset Correction: v_off_ini = 747.993 uV, v_off_fin = 749.070 uV 12:28:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.999 uVs 12:28:24 I2Y Average and RMS of Measurements VT = -289.647 +- 1.487 uVs I2Y = -26.648 +- 0.137 uTm^2 12:28:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:41 Integrated Voltage Measurement... 12:28:50 Voltage Offset Correction: v_off_ini = 729.249 uV, v_off_fin = 728.334 uV 12:28:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -131.789 uVs 12:28:51 Integrated Voltage Measurement... 12:28:59 Voltage Offset Correction: v_off_ini = 730.352 uV, v_off_fin = 735.062 uV 12:28:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.315 uVs 12:29:00 Integrated Voltage Measurement... 12:29:08 Voltage Offset Correction: v_off_ini = 734.470 uV, v_off_fin = 735.881 uV 12:29:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.942 uVs 12:29:09 Integrated Voltage Measurement... 12:29:17 Voltage Offset Correction: v_off_ini = 743.806 uV, v_off_fin = 754.380 uV 12:29:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.777 uVs 12:29:18 Integrated Voltage Measurement... 12:29:27 Voltage Offset Correction: v_off_ini = 737.752 uV, v_off_fin = 752.965 uV 12:29:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.756 uVs 12:29:27 Integrated Voltage Measurement... 12:29:36 Voltage Offset Correction: v_off_ini = 746.404 uV, v_off_fin = 769.510 uV 12:29:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.272 uVs 12:29:40 I1X Average and RMS of Measurements VT = -98.142 +- 14.034 uVs I1X = 19.629 +- 2.807 uTm 12:29:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:47 Integrated Voltage Measurement... 12:29:55 Voltage Offset Correction: v_off_ini = 755.777 uV, v_off_fin = 739.793 uV 12:29:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.467 uVs 12:29:55 Integrated Voltage Measurement... 12:30:04 Voltage Offset Correction: v_off_ini = 756.043 uV, v_off_fin = 773.830 uV 12:30:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.158 uVs 12:30:05 Integrated Voltage Measurement... 12:30:13 Voltage Offset Correction: v_off_ini = 769.171 uV, v_off_fin = 744.369 uV 12:30:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -251.115 uVs 12:30:13 Integrated Voltage Measurement... 12:30:22 Voltage Offset Correction: v_off_ini = 766.296 uV, v_off_fin = 752.004 uV 12:30:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 238.789 uVs 12:30:22 Integrated Voltage Measurement... 12:30:31 Voltage Offset Correction: v_off_ini = 752.340 uV, v_off_fin = 723.801 uV 12:30:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.694 uVs 12:30:31 Integrated Voltage Measurement... 12:30:40 Voltage Offset Correction: v_off_ini = 750.963 uV, v_off_fin = 760.316 uV 12:30:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.513 uVs 12:30:45 I1Y Average and RMS of Measurements VT = -246.123 +- 2.124 uVs I1Y = -49.222 +- 0.426 uTm 12:30:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:52 Integrated Voltage Measurement... 12:31:01 Voltage Offset Correction: v_off_ini = 751.134 uV, v_off_fin = 752.604 uV 12:31:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -84.202 uVs 12:31:01 Integrated Voltage Measurement... 12:31:10 Voltage Offset Correction: v_off_ini = 752.590 uV, v_off_fin = 778.235 uV 12:31:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.916 uVs 12:31:10 Integrated Voltage Measurement... 12:31:19 Voltage Offset Correction: v_off_ini = 766.766 uV, v_off_fin = 740.692 uV 12:31:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.047 uVs 12:31:19 Integrated Voltage Measurement... 12:31:28 Voltage Offset Correction: v_off_ini = 755.182 uV, v_off_fin = 771.852 uV 12:31:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.050 uVs 12:31:28 Integrated Voltage Measurement... 12:31:37 Voltage Offset Correction: v_off_ini = 746.263 uV, v_off_fin = 732.842 uV 12:31:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.315 uVs 12:31:37 Integrated Voltage Measurement... 12:31:46 Voltage Offset Correction: v_off_ini = 747.132 uV, v_off_fin = 759.417 uV 12:31:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.517 uVs 12:31:49 I2X Average and RMS of Measurements VT = -99.508 +- 7.432 uVs I2X = 9.155 +- 0.684 uTm^2 12:31:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:31:57 Integrated Voltage Measurement... 12:32:05 Voltage Offset Correction: v_off_ini = 753.852 uV, v_off_fin = 750.254 uV 12:32:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.438 uVs 12:32:06 Integrated Voltage Measurement... 12:32:14 Voltage Offset Correction: v_off_ini = 764.613 uV, v_off_fin = 765.887 uV 12:32:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.772 uVs 12:32:15 Integrated Voltage Measurement... 12:32:24 Voltage Offset Correction: v_off_ini = 776.066 uV, v_off_fin = 758.216 uV 12:32:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.725 uVs 12:32:24 Integrated Voltage Measurement... 12:32:33 Voltage Offset Correction: v_off_ini = 768.238 uV, v_off_fin = 782.475 uV 12:32:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.900 uVs 12:32:33 Integrated Voltage Measurement... 12:32:42 Voltage Offset Correction: v_off_ini = 768.886 uV, v_off_fin = 759.970 uV 12:32:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.515 uVs 12:32:42 Integrated Voltage Measurement... 12:32:51 Voltage Offset Correction: v_off_ini = 764.724 uV, v_off_fin = 761.046 uV 12:32:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.054 uVs 12:32:53 I2Y Average and RMS of Measurements VT = -286.234 +- 2.870 uVs I2Y = -26.334 +- 0.264 uTm^2 12:33:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:33:17 Integrated Voltage Measurement... 12:33:26 Voltage Offset Correction: v_off_ini = 768.283 uV, v_off_fin = 769.063 uV 12:33:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -82.619 uVs 12:33:26 Integrated Voltage Measurement... 12:33:35 Voltage Offset Correction: v_off_ini = 770.398 uV, v_off_fin = 761.891 uV 12:33:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.115 uVs 12:33:35 Integrated Voltage Measurement... 12:33:44 Voltage Offset Correction: v_off_ini = 761.595 uV, v_off_fin = 758.666 uV 12:33:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.098 uVs 12:33:44 Integrated Voltage Measurement... 12:33:53 Voltage Offset Correction: v_off_ini = 768.116 uV, v_off_fin = 755.348 uV 12:33:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.162 uVs 12:33:53 Integrated Voltage Measurement... 12:34:02 Voltage Offset Correction: v_off_ini = 765.438 uV, v_off_fin = 759.249 uV 12:34:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.742 uVs 12:34:02 Integrated Voltage Measurement... 12:34:11 Voltage Offset Correction: v_off_ini = 781.193 uV, v_off_fin = 772.888 uV 12:34:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.332 uVs 12:34:15 I1X Average and RMS of Measurements VT = -86.511 +- 6.394 uVs I1X = 17.303 +- 1.278 uTm 12:34:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:34:22 Integrated Voltage Measurement... 12:34:31 Voltage Offset Correction: v_off_ini = 779.597 uV, v_off_fin = 767.581 uV 12:34:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.854 uVs 12:34:31 Integrated Voltage Measurement... 12:34:40 Voltage Offset Correction: v_off_ini = 779.285 uV, v_off_fin = 797.025 uV 12:34:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 251.576 uVs 12:34:40 Integrated Voltage Measurement... 12:34:49 Voltage Offset Correction: v_off_ini = 785.225 uV, v_off_fin = 761.850 uV 12:34:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -245.868 uVs 12:34:49 Integrated Voltage Measurement... 12:34:58 Voltage Offset Correction: v_off_ini = 781.305 uV, v_off_fin = 788.588 uV 12:34:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 248.857 uVs 12:34:58 Integrated Voltage Measurement... 12:35:07 Voltage Offset Correction: v_off_ini = 795.748 uV, v_off_fin = 774.086 uV 12:35:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.203 uVs 12:35:07 Integrated Voltage Measurement... 12:35:16 Voltage Offset Correction: v_off_ini = 791.858 uV, v_off_fin = 802.729 uV 12:35:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 247.725 uVs 12:35:20 I1Y Average and RMS of Measurements VT = -245.847 +- 1.288 uVs I1Y = -49.168 +- 0.257 uTm 12:35:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:35:28 Integrated Voltage Measurement... 12:35:37 Voltage Offset Correction: v_off_ini = 781.375 uV, v_off_fin = 787.007 uV 12:35:37 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -87.887 uVs 12:35:37 Integrated Voltage Measurement... 12:35:46 Voltage Offset Correction: v_off_ini = 780.855 uV, v_off_fin = 797.318 uV 12:35:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.133 uVs 12:35:46 Integrated Voltage Measurement... 12:35:55 Voltage Offset Correction: v_off_ini = 813.342 uV, v_off_fin = 803.782 uV 12:35:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.126 uVs 12:35:55 Integrated Voltage Measurement... 12:36:04 Voltage Offset Correction: v_off_ini = 813.906 uV, v_off_fin = 799.765 uV 12:36:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.342 uVs 12:36:04 Integrated Voltage Measurement... 12:36:13 Voltage Offset Correction: v_off_ini = 809.146 uV, v_off_fin = 796.275 uV 12:36:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.105 uVs 12:36:13 Integrated Voltage Measurement... 12:36:22 Voltage Offset Correction: v_off_ini = 792.741 uV, v_off_fin = 787.189 uV 12:36:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.402 uVs 12:36:24 I2X Average and RMS of Measurements VT = -97.332 +- 9.856 uVs I2X = 8.954 +- 0.906 uTm^2 12:36:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:36:32 Integrated Voltage Measurement... 12:36:41 Voltage Offset Correction: v_off_ini = 781.024 uV, v_off_fin = 791.237 uV 12:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.170 uVs 12:36:41 Integrated Voltage Measurement... 12:36:50 Voltage Offset Correction: v_off_ini = 793.122 uV, v_off_fin = 798.078 uV 12:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.858 uVs 12:36:50 Integrated Voltage Measurement... 12:36:59 Voltage Offset Correction: v_off_ini = 785.117 uV, v_off_fin = 784.306 uV 12:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.157 uVs 12:36:59 Integrated Voltage Measurement... 12:37:08 Voltage Offset Correction: v_off_ini = 795.493 uV, v_off_fin = 783.443 uV 12:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.823 uVs 12:37:08 Integrated Voltage Measurement... 12:37:17 Voltage Offset Correction: v_off_ini = 790.656 uV, v_off_fin = 790.972 uV 12:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.542 uVs 12:37:17 Integrated Voltage Measurement... 12:37:26 Voltage Offset Correction: v_off_ini = 796.860 uV, v_off_fin = 795.565 uV 12:37:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.633 uVs 12:37:29 I2Y Average and RMS of Measurements VT = -298.530 +- 12.358 uVs I2Y = -27.465 +- 1.137 uTm^2 12:37:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:37:46 Integrated Voltage Measurement... 12:37:55 Voltage Offset Correction: v_off_ini = 788.847 uV, v_off_fin = 786.252 uV 12:37:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.865 uVs 12:37:55 Integrated Voltage Measurement... 12:38:04 Voltage Offset Correction: v_off_ini = 785.858 uV, v_off_fin = 782.144 uV 12:38:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.028 uVs 12:38:04 Integrated Voltage Measurement... 12:38:13 Voltage Offset Correction: v_off_ini = 755.192 uV, v_off_fin = 767.880 uV 12:38:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.136 uVs 12:38:13 Integrated Voltage Measurement... 12:38:22 Voltage Offset Correction: v_off_ini = 761.001 uV, v_off_fin = 756.274 uV 12:38:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.121 uVs 12:38:22 Integrated Voltage Measurement... 12:38:31 Voltage Offset Correction: v_off_ini = 763.181 uV, v_off_fin = 766.854 uV 12:38:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.393 uVs 12:38:31 Integrated Voltage Measurement... 12:38:40 Voltage Offset Correction: v_off_ini = 761.272 uV, v_off_fin = 783.619 uV 12:38:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.234 uVs 12:38:44 I1X Average and RMS of Measurements VT = -92.463 +- 6.634 uVs I1X = 18.493 +- 1.327 uTm 12:38:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:38:51 Integrated Voltage Measurement... 12:39:00 Voltage Offset Correction: v_off_ini = 765.561 uV, v_off_fin = 759.017 uV 12:39:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.089 uVs 12:39:00 Integrated Voltage Measurement... 12:39:09 Voltage Offset Correction: v_off_ini = 787.227 uV, v_off_fin = 813.867 uV 12:39:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 263.316 uVs 12:39:09 Integrated Voltage Measurement... 12:39:18 Voltage Offset Correction: v_off_ini = 777.363 uV, v_off_fin = 770.669 uV 12:39:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.443 uVs 12:39:18 Integrated Voltage Measurement... 12:39:27 Voltage Offset Correction: v_off_ini = 795.530 uV, v_off_fin = 805.417 uV 12:39:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 265.798 uVs 12:39:27 Integrated Voltage Measurement... 12:39:36 Voltage Offset Correction: v_off_ini = 788.500 uV, v_off_fin = 779.015 uV 12:39:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -255.689 uVs 12:39:36 Integrated Voltage Measurement... 12:39:45 Voltage Offset Correction: v_off_ini = 769.402 uV, v_off_fin = 792.575 uV 12:39:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 285.403 uVs 12:39:49 I1Y Average and RMS of Measurements VT = -256.290 +- 10.218 uVs I1Y = -51.254 +- 2.043 uTm 12:39:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:39:57 Integrated Voltage Measurement... 12:40:06 Voltage Offset Correction: v_off_ini = 766.423 uV, v_off_fin = 796.031 uV 12:40:06 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -105.792 uVs 12:40:06 Integrated Voltage Measurement... 12:40:15 Voltage Offset Correction: v_off_ini = 821.497 uV, v_off_fin = 827.425 uV 12:40:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.107 uVs 12:40:15 Integrated Voltage Measurement... 12:40:24 Voltage Offset Correction: v_off_ini = 817.380 uV, v_off_fin = 810.743 uV 12:40:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -103.101 uVs 12:40:24 Integrated Voltage Measurement... 12:40:33 Voltage Offset Correction: v_off_ini = 814.015 uV, v_off_fin = 821.950 uV 12:40:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.565 uVs 12:40:33 Integrated Voltage Measurement... 12:40:42 Voltage Offset Correction: v_off_ini = 791.630 uV, v_off_fin = 809.100 uV 12:40:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.627 uVs 12:40:42 Integrated Voltage Measurement... 12:40:51 Voltage Offset Correction: v_off_ini = 835.635 uV, v_off_fin = 831.298 uV 12:40:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.220 uVs 12:40:54 I2X Average and RMS of Measurements VT = -106.735 +- 1.935 uVs I2X = 9.819 +- 0.178 uTm^2 12:40:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:41:01 Integrated Voltage Measurement... 12:41:10 Voltage Offset Correction: v_off_ini = 820.138 uV, v_off_fin = 817.456 uV 12:41:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.481 uVs 12:41:10 Integrated Voltage Measurement... 12:41:19 Voltage Offset Correction: v_off_ini = 815.506 uV, v_off_fin = 799.659 uV 12:41:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.268 uVs 12:41:19 Integrated Voltage Measurement... 12:41:28 Voltage Offset Correction: v_off_ini = 802.732 uV, v_off_fin = 817.121 uV 12:41:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.722 uVs 12:41:28 Integrated Voltage Measurement... 12:41:37 Voltage Offset Correction: v_off_ini = 820.776 uV, v_off_fin = 820.200 uV 12:41:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.842 uVs 12:41:37 Integrated Voltage Measurement... 12:41:46 Voltage Offset Correction: v_off_ini = 836.748 uV, v_off_fin = 818.586 uV 12:41:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.994 uVs 12:41:46 Integrated Voltage Measurement... 12:41:55 Voltage Offset Correction: v_off_ini = 822.672 uV, v_off_fin = 815.261 uV 12:41:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.206 uVs 12:41:58 I2Y Average and RMS of Measurements VT = -296.752 +- 1.561 uVs I2Y = -27.301 +- 0.144 uTm^2 12:42:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:42:15 Integrated Voltage Measurement... 12:42:24 Voltage Offset Correction: v_off_ini = 792.984 uV, v_off_fin = 811.381 uV 12:42:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.294 uVs 12:42:24 Integrated Voltage Measurement... 12:42:33 Voltage Offset Correction: v_off_ini = 831.277 uV, v_off_fin = 812.161 uV 12:42:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.772 uVs 12:42:33 Integrated Voltage Measurement... 12:42:42 Voltage Offset Correction: v_off_ini = 828.547 uV, v_off_fin = 818.284 uV 12:42:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.398 uVs 12:42:42 Integrated Voltage Measurement... 12:42:51 Voltage Offset Correction: v_off_ini = 829.028 uV, v_off_fin = 831.058 uV 12:42:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.279 uVs 12:42:51 Integrated Voltage Measurement... 12:43:00 Voltage Offset Correction: v_off_ini = 813.192 uV, v_off_fin = 808.801 uV 12:43:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.688 uVs 12:43:00 Integrated Voltage Measurement... 12:43:09 Voltage Offset Correction: v_off_ini = 810.999 uV, v_off_fin = 813.173 uV 12:43:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.675 uVs 12:43:13 I1X Average and RMS of Measurements VT = -89.351 +- 11.696 uVs I1X = 17.870 +- 2.339 uTm 12:43:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:43:20 Integrated Voltage Measurement... 12:43:29 Voltage Offset Correction: v_off_ini = 821.623 uV, v_off_fin = 809.364 uV 12:43:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.250 uVs 12:43:29 Integrated Voltage Measurement... 12:43:38 Voltage Offset Correction: v_off_ini = 844.665 uV, v_off_fin = 843.398 uV 12:43:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.153 uVs 12:43:38 Integrated Voltage Measurement... 12:43:47 Voltage Offset Correction: v_off_ini = 818.446 uV, v_off_fin = 791.779 uV 12:43:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.002 uVs 12:43:47 Integrated Voltage Measurement... 12:43:56 Voltage Offset Correction: v_off_ini = 810.463 uV, v_off_fin = 806.307 uV 12:43:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.240 uVs 12:43:56 Integrated Voltage Measurement... 12:44:05 Voltage Offset Correction: v_off_ini = 782.604 uV, v_off_fin = 773.881 uV 12:44:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.575 uVs 12:44:05 Integrated Voltage Measurement... 12:44:14 Voltage Offset Correction: v_off_ini = 806.077 uV, v_off_fin = 810.197 uV 12:44:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.141 uVs 12:44:18 I1Y Average and RMS of Measurements VT = -251.393 +- 7.982 uVs I1Y = -50.279 +- 1.596 uTm 12:44:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:44:26 Integrated Voltage Measurement... 12:44:35 Voltage Offset Correction: v_off_ini = 774.730 uV, v_off_fin = 779.765 uV 12:44:35 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -91.059 uVs 12:44:35 Integrated Voltage Measurement... 12:44:44 Voltage Offset Correction: v_off_ini = 803.514 uV, v_off_fin = 811.473 uV 12:44:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.821 uVs 12:44:44 Integrated Voltage Measurement... 12:44:53 Voltage Offset Correction: v_off_ini = 789.336 uV, v_off_fin = 776.188 uV 12:44:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.752 uVs 12:44:53 Integrated Voltage Measurement... 12:45:02 Voltage Offset Correction: v_off_ini = 781.962 uV, v_off_fin = 783.443 uV 12:45:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.523 uVs 12:45:02 Integrated Voltage Measurement... 12:45:11 Voltage Offset Correction: v_off_ini = 762.059 uV, v_off_fin = 751.204 uV 12:45:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.969 uVs 12:45:11 Integrated Voltage Measurement... 12:45:20 Voltage Offset Correction: v_off_ini = 773.889 uV, v_off_fin = 795.909 uV 12:45:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.633 uVs 12:45:23 I2X Average and RMS of Measurements VT = -95.793 +- 5.968 uVs I2X = 8.813 +- 0.549 uTm^2 12:45:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:45:30 Integrated Voltage Measurement... 12:45:39 Voltage Offset Correction: v_off_ini = 760.951 uV, v_off_fin = 791.378 uV 12:45:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0002 mm dXY = 1.0000 mm VT = -316.948 uVs 12:45:40 Integrated Voltage Measurement... 12:45:49 Voltage Offset Correction: v_off_ini = 789.605 uV, v_off_fin = 767.899 uV 12:45:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 300.611 uVs 12:45:49 Integrated Voltage Measurement... 12:45:58 Voltage Offset Correction: v_off_ini = 780.412 uV, v_off_fin = 794.073 uV 12:45:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.924 uVs 12:45:58 Integrated Voltage Measurement... 12:46:07 Voltage Offset Correction: v_off_ini = 786.364 uV, v_off_fin = 775.663 uV 12:46:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.858 uVs 12:46:07 Integrated Voltage Measurement... 12:46:16 Voltage Offset Correction: v_off_ini = 747.348 uV, v_off_fin = 757.549 uV 12:46:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.302 uVs 12:46:16 Integrated Voltage Measurement... 12:46:25 Voltage Offset Correction: v_off_ini = 773.053 uV, v_off_fin = 778.038 uV 12:46:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.275 uVs 12:46:27 I2Y Average and RMS of Measurements VT = -298.320 +- 8.783 uVs I2Y = -27.445 +- 0.808 uTm^2 12:46:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:46:44 Integrated Voltage Measurement... 12:46:53 Voltage Offset Correction: v_off_ini = 779.694 uV, v_off_fin = 762.662 uV 12:46:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -104.465 uVs 12:46:53 Integrated Voltage Measurement... 12:47:02 Voltage Offset Correction: v_off_ini = 757.616 uV, v_off_fin = 739.449 uV 12:47:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.827 uVs 12:47:03 Integrated Voltage Measurement... 12:47:11 Voltage Offset Correction: v_off_ini = 743.215 uV, v_off_fin = 748.088 uV 12:47:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.441 uVs 12:47:12 Integrated Voltage Measurement... 12:47:21 Voltage Offset Correction: v_off_ini = 778.285 uV, v_off_fin = 760.329 uV 12:47:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.191 uVs 12:47:21 Integrated Voltage Measurement... 12:47:30 Voltage Offset Correction: v_off_ini = 765.789 uV, v_off_fin = 744.687 uV 12:47:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.320 uVs 12:47:30 Integrated Voltage Measurement... 12:47:39 Voltage Offset Correction: v_off_ini = 756.122 uV, v_off_fin = 766.425 uV 12:47:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.892 uVs 12:47:43 I1X Average and RMS of Measurements VT = -93.356 +- 7.978 uVs I1X = 18.672 +- 1.596 uTm 12:47:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:47:50 Integrated Voltage Measurement... 12:47:59 Voltage Offset Correction: v_off_ini = 778.704 uV, v_off_fin = 755.487 uV 12:47:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.042 uVs 12:47:59 Integrated Voltage Measurement... 12:48:08 Voltage Offset Correction: v_off_ini = 762.028 uV, v_off_fin = 768.874 uV 12:48:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.920 uVs 12:48:08 Integrated Voltage Measurement... 12:48:17 Voltage Offset Correction: v_off_ini = 771.846 uV, v_off_fin = 764.828 uV 12:48:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.941 uVs 12:48:17 Integrated Voltage Measurement... 12:48:26 Voltage Offset Correction: v_off_ini = 761.407 uV, v_off_fin = 786.218 uV 12:48:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 276.334 uVs 12:48:26 Integrated Voltage Measurement... 12:48:35 Voltage Offset Correction: v_off_ini = 779.844 uV, v_off_fin = 758.252 uV 12:48:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.631 uVs 12:48:35 Integrated Voltage Measurement... 12:48:44 Voltage Offset Correction: v_off_ini = 767.038 uV, v_off_fin = 801.656 uV 12:48:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.974 uVs 12:48:48 I1Y Average and RMS of Measurements VT = -256.307 +- 1.780 uVs I1Y = -51.261 +- 0.356 uTm 12:48:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:48:56 Integrated Voltage Measurement... 12:49:05 Voltage Offset Correction: v_off_ini = 780.872 uV, v_off_fin = 751.230 uV 12:49:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.659 uVs 12:49:05 Integrated Voltage Measurement... 12:49:14 Voltage Offset Correction: v_off_ini = 754.859 uV, v_off_fin = 780.473 uV 12:49:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.183 uVs 12:49:14 Integrated Voltage Measurement... 12:49:23 Voltage Offset Correction: v_off_ini = 772.576 uV, v_off_fin = 761.908 uV 12:49:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.815 uVs 12:49:23 Integrated Voltage Measurement... 12:49:32 Voltage Offset Correction: v_off_ini = 753.712 uV, v_off_fin = 739.922 uV 12:49:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.638 uVs 12:49:32 Integrated Voltage Measurement... 12:49:41 Voltage Offset Correction: v_off_ini = 736.036 uV, v_off_fin = 719.354 uV 12:49:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -145.284 uVs 12:49:41 Integrated Voltage Measurement... 12:49:50 Voltage Offset Correction: v_off_ini = 739.155 uV, v_off_fin = 739.487 uV 12:49:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.262 uVs 12:49:52 I2X Average and RMS of Measurements VT = -111.307 +- 5.025 uVs I2X = 10.240 +- 0.462 uTm^2 12:49:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:50:00 Integrated Voltage Measurement... 12:50:09 Voltage Offset Correction: v_off_ini = 755.918 uV, v_off_fin = 745.500 uV 12:50:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -309.517 uVs 12:50:09 Integrated Voltage Measurement... 12:50:18 Voltage Offset Correction: v_off_ini = 759.346 uV, v_off_fin = 734.597 uV 12:50:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.817 uVs 12:50:18 Integrated Voltage Measurement... 12:50:27 Voltage Offset Correction: v_off_ini = 751.938 uV, v_off_fin = 740.653 uV 12:50:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.324 uVs 12:50:27 Integrated Voltage Measurement... 12:50:36 Voltage Offset Correction: v_off_ini = 748.002 uV, v_off_fin = 739.367 uV 12:50:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.321 uVs 12:50:36 Integrated Voltage Measurement... 12:50:45 Voltage Offset Correction: v_off_ini = 738.298 uV, v_off_fin = 728.075 uV 12:50:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.373 uVs 12:50:45 Integrated Voltage Measurement... 12:50:54 Voltage Offset Correction: v_off_ini = 745.498 uV, v_off_fin = 749.560 uV 12:50:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.363 uVs 12:50:57 I2Y Average and RMS of Measurements VT = -285.786 +- 8.899 uVs I2Y = -26.293 +- 0.819 uTm^2 12:50:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm