SLAC Magnetic Measurements Date: 12-09-2024 Time: 12:28:55 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10082 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 5 Measurement Device: Stretched Wire Operator: YL Comment: Off Axis 12:29:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:06 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:29:08 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:29:09 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:29:11 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:29:28 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:29:32 Integrated Voltage Measurement... 12:29:41 Voltage Offset Correction: v_off_ini = -29.206 uV, v_off_fin = -24.916 uV 12:29:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.318 uVs 12:29:41 Integrated Voltage Measurement... 12:29:50 Voltage Offset Correction: v_off_ini = -14.088 uV, v_off_fin = -21.898 uV 12:29:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.679 uVs 12:29:51 Integrated Voltage Measurement... 12:29:59 Voltage Offset Correction: v_off_ini = -11.565 uV, v_off_fin = -11.626 uV 12:30:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.482 uVs 12:30:00 Integrated Voltage Measurement... 12:30:08 Voltage Offset Correction: v_off_ini = 4.218 uV, v_off_fin = -16.388 uV 12:30:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.161 uVs 12:30:09 Integrated Voltage Measurement... 12:30:18 Voltage Offset Correction: v_off_ini = -32.960 uV, v_off_fin = -19.176 uV 12:30:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.386 uVs 12:30:18 Integrated Voltage Measurement... 12:30:27 Voltage Offset Correction: v_off_ini = -3.873 uV, v_off_fin = -3.218 uV 12:30:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.415 uVs 12:30:31 I1X Average and RMS of Measurements VT = -92.574 +- 8.457 uVs I1X = 18.515 +- 1.691 uTm 12:30:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:30:38 Integrated Voltage Measurement... 12:30:47 Voltage Offset Correction: v_off_ini = 8.446 uV, v_off_fin = 11.781 uV 12:30:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.122 uVs 12:30:47 Integrated Voltage Measurement... 12:30:56 Voltage Offset Correction: v_off_ini = -1.447 uV, v_off_fin = 29.444 uV 12:30:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.998 uVs 12:30:56 Integrated Voltage Measurement... 12:31:05 Voltage Offset Correction: v_off_ini = 21.506 uV, v_off_fin = 3.735 uV 12:31:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.797 uVs 12:31:05 Integrated Voltage Measurement... 12:31:14 Voltage Offset Correction: v_off_ini = 26.492 uV, v_off_fin = 38.374 uV 12:31:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.041 uVs 12:31:14 Integrated Voltage Measurement... 12:31:23 Voltage Offset Correction: v_off_ini = 7.285 uV, v_off_fin = 9.855 uV 12:31:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.109 uVs 12:31:23 Integrated Voltage Measurement... 12:31:32 Voltage Offset Correction: v_off_ini = 28.317 uV, v_off_fin = 24.582 uV 12:31:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.165 uVs 12:31:36 I1Y Average and RMS of Measurements VT = -216.539 +- 8.644 uVs I1Y = -43.308 +- 1.729 uTm 12:31:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:31:44 Integrated Voltage Measurement... 12:31:52 Voltage Offset Correction: v_off_ini = 24.724 uV, v_off_fin = 33.984 uV 12:31:53 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.126 uVs 12:31:53 Integrated Voltage Measurement... 12:32:02 Voltage Offset Correction: v_off_ini = 32.422 uV, v_off_fin = 36.357 uV 12:32:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.838 uVs 12:32:02 Integrated Voltage Measurement... 12:32:11 Voltage Offset Correction: v_off_ini = 33.336 uV, v_off_fin = 26.886 uV 12:32:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.966 uVs 12:32:11 Integrated Voltage Measurement... 12:32:20 Voltage Offset Correction: v_off_ini = 37.117 uV, v_off_fin = 46.320 uV 12:32:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.089 uVs 12:32:20 Integrated Voltage Measurement... 12:32:29 Voltage Offset Correction: v_off_ini = 59.389 uV, v_off_fin = 51.003 uV 12:32:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.818 uVs 12:32:29 Integrated Voltage Measurement... 12:32:38 Voltage Offset Correction: v_off_ini = 54.150 uV, v_off_fin = 58.473 uV 12:32:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.156 uVs 12:32:40 I2X Average and RMS of Measurements VT = -99.999 +- 9.995 uVs I2X = 9.200 +- 0.920 uTm^2 12:32:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:32:48 Integrated Voltage Measurement... 12:32:57 Voltage Offset Correction: v_off_ini = 40.183 uV, v_off_fin = 66.727 uV 12:32:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.008 uVs 12:32:57 Integrated Voltage Measurement... 12:33:06 Voltage Offset Correction: v_off_ini = 62.934 uV, v_off_fin = 60.977 uV 12:33:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.623 uVs 12:33:06 Integrated Voltage Measurement... 12:33:15 Voltage Offset Correction: v_off_ini = 40.542 uV, v_off_fin = 57.277 uV 12:33:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.232 uVs 12:33:15 Integrated Voltage Measurement... 12:33:24 Voltage Offset Correction: v_off_ini = 34.095 uV, v_off_fin = 44.217 uV 12:33:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.607 uVs 12:33:24 Integrated Voltage Measurement... 12:33:33 Voltage Offset Correction: v_off_ini = 41.295 uV, v_off_fin = 45.587 uV 12:33:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.233 uVs 12:33:33 Integrated Voltage Measurement... 12:33:42 Voltage Offset Correction: v_off_ini = 45.087 uV, v_off_fin = 29.697 uV 12:33:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.324 uVs 12:33:45 I2Y Average and RMS of Measurements VT = -293.005 +- 14.779 uVs I2Y = -26.956 +- 1.360 uTm^2 12:33:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:33:53 Integrated Voltage Measurement... 12:34:02 Voltage Offset Correction: v_off_ini = 58.070 uV, v_off_fin = 41.288 uV 12:34:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.884 uVs 12:34:02 Integrated Voltage Measurement... 12:34:11 Voltage Offset Correction: v_off_ini = 43.422 uV, v_off_fin = 43.134 uV 12:34:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.410 uVs 12:34:11 Integrated Voltage Measurement... 12:34:20 Voltage Offset Correction: v_off_ini = 28.828 uV, v_off_fin = 34.190 uV 12:34:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.140 uVs 12:34:20 Integrated Voltage Measurement... 12:34:29 Voltage Offset Correction: v_off_ini = 19.937 uV, v_off_fin = 29.479 uV 12:34:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.948 uVs 12:34:30 Integrated Voltage Measurement... 12:34:39 Voltage Offset Correction: v_off_ini = 49.717 uV, v_off_fin = 56.475 uV 12:34:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.763 uVs 12:34:39 Integrated Voltage Measurement... 12:34:48 Voltage Offset Correction: v_off_ini = 45.124 uV, v_off_fin = 40.000 uV 12:34:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.537 uVs 12:34:52 I1X Average and RMS of Measurements VT = -92.447 +- 4.600 uVs I1X = 18.490 +- 0.920 uTm 12:34:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:34:59 Integrated Voltage Measurement... 12:35:07 Voltage Offset Correction: v_off_ini = 37.630 uV, v_off_fin = 32.516 uV 12:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.787 uVs 12:35:08 Integrated Voltage Measurement... 12:35:16 Voltage Offset Correction: v_off_ini = 28.025 uV, v_off_fin = 56.794 uV 12:35:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.643 uVs 12:35:17 Integrated Voltage Measurement... 12:35:25 Voltage Offset Correction: v_off_ini = 40.952 uV, v_off_fin = 52.733 uV 12:35:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.668 uVs 12:35:26 Integrated Voltage Measurement... 12:35:35 Voltage Offset Correction: v_off_ini = 62.333 uV, v_off_fin = 57.355 uV 12:35:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.561 uVs 12:35:35 Integrated Voltage Measurement... 12:35:44 Voltage Offset Correction: v_off_ini = 53.235 uV, v_off_fin = 32.813 uV 12:35:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.397 uVs 12:35:44 Integrated Voltage Measurement... 12:35:53 Voltage Offset Correction: v_off_ini = 61.309 uV, v_off_fin = 70.665 uV 12:35:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.447 uVs 12:35:57 I1Y Average and RMS of Measurements VT = -204.751 +- 4.971 uVs I1Y = -40.950 +- 0.994 uTm 12:36:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:36:05 Integrated Voltage Measurement... 12:36:13 Voltage Offset Correction: v_off_ini = 44.525 uV, v_off_fin = 43.654 uV 12:36:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.871 uVs 12:36:14 Integrated Voltage Measurement... 12:36:23 Voltage Offset Correction: v_off_ini = 42.428 uV, v_off_fin = 47.114 uV 12:36:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.278 uVs 12:36:23 Integrated Voltage Measurement... 12:36:32 Voltage Offset Correction: v_off_ini = 62.752 uV, v_off_fin = 59.917 uV 12:36:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.467 uVs 12:36:32 Integrated Voltage Measurement... 12:36:41 Voltage Offset Correction: v_off_ini = 58.368 uV, v_off_fin = 83.009 uV 12:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.354 uVs 12:36:41 Integrated Voltage Measurement... 12:36:50 Voltage Offset Correction: v_off_ini = 55.449 uV, v_off_fin = 58.035 uV 12:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.519 uVs 12:36:50 Integrated Voltage Measurement... 12:36:59 Voltage Offset Correction: v_off_ini = 68.620 uV, v_off_fin = 65.723 uV 12:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.980 uVs 12:37:01 I2X Average and RMS of Measurements VT = -101.078 +- 2.789 uVs I2X = 9.299 +- 0.257 uTm^2 12:37:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:37:09 Integrated Voltage Measurement... 12:37:18 Voltage Offset Correction: v_off_ini = 53.803 uV, v_off_fin = 62.851 uV 12:37:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.972 uVs 12:37:18 Integrated Voltage Measurement... 12:37:27 Voltage Offset Correction: v_off_ini = 56.548 uV, v_off_fin = 74.377 uV 12:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.072 uVs 12:37:27 Integrated Voltage Measurement... 12:37:36 Voltage Offset Correction: v_off_ini = 65.216 uV, v_off_fin = 59.134 uV 12:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.531 uVs 12:37:36 Integrated Voltage Measurement... 12:37:45 Voltage Offset Correction: v_off_ini = 70.155 uV, v_off_fin = 68.067 uV 12:37:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.494 uVs 12:37:45 Integrated Voltage Measurement... 12:37:54 Voltage Offset Correction: v_off_ini = 70.561 uV, v_off_fin = 75.122 uV 12:37:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.713 uVs 12:37:54 Integrated Voltage Measurement... 12:38:03 Voltage Offset Correction: v_off_ini = 51.593 uV, v_off_fin = 71.047 uV 12:38:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.512 uVs 12:38:05 I2Y Average and RMS of Measurements VT = -287.216 +- 2.859 uVs I2Y = -26.424 +- 0.263 uTm^2 12:38:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:38:14 Integrated Voltage Measurement... 12:38:23 Voltage Offset Correction: v_off_ini = 58.889 uV, v_off_fin = 64.155 uV 12:38:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.519 uVs 12:38:23 Integrated Voltage Measurement... 12:38:32 Voltage Offset Correction: v_off_ini = 55.594 uV, v_off_fin = 57.291 uV 12:38:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.349 uVs 12:38:32 Integrated Voltage Measurement... 12:38:41 Voltage Offset Correction: v_off_ini = 66.898 uV, v_off_fin = 64.497 uV 12:38:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.711 uVs 12:38:41 Integrated Voltage Measurement... 12:38:50 Voltage Offset Correction: v_off_ini = 66.574 uV, v_off_fin = 56.287 uV 12:38:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.763 uVs 12:38:50 Integrated Voltage Measurement... 12:38:59 Voltage Offset Correction: v_off_ini = 68.182 uV, v_off_fin = 67.944 uV 12:38:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.390 uVs 12:38:59 Integrated Voltage Measurement... 12:39:08 Voltage Offset Correction: v_off_ini = 59.579 uV, v_off_fin = 30.595 uV 12:39:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.843 uVs 12:39:13 I1X Average and RMS of Measurements VT = -70.929 +- 3.401 uVs I1X = 14.186 +- 0.680 uTm 12:39:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:39:19 Integrated Voltage Measurement... 12:39:28 Voltage Offset Correction: v_off_ini = 66.219 uV, v_off_fin = 57.966 uV 12:39:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.141 uVs 12:39:28 Integrated Voltage Measurement... 12:39:37 Voltage Offset Correction: v_off_ini = 52.350 uV, v_off_fin = 63.866 uV 12:39:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.981 uVs 12:39:37 Integrated Voltage Measurement... 12:39:46 Voltage Offset Correction: v_off_ini = 44.999 uV, v_off_fin = 44.084 uV 12:39:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.820 uVs 12:39:47 Integrated Voltage Measurement... 12:39:55 Voltage Offset Correction: v_off_ini = 56.943 uV, v_off_fin = 63.643 uV 12:39:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.531 uVs 12:39:56 Integrated Voltage Measurement... 12:40:04 Voltage Offset Correction: v_off_ini = 37.627 uV, v_off_fin = 48.932 uV 12:40:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.341 uVs 12:40:05 Integrated Voltage Measurement... 12:40:13 Voltage Offset Correction: v_off_ini = 40.106 uV, v_off_fin = 57.368 uV 12:40:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.145 uVs 12:40:18 I1Y Average and RMS of Measurements VT = -187.993 +- 4.244 uVs I1Y = -37.599 +- 0.849 uTm 12:40:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:40:25 Integrated Voltage Measurement... 12:40:34 Voltage Offset Correction: v_off_ini = 77.964 uV, v_off_fin = 86.844 uV 12:40:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.664 uVs 12:40:34 Integrated Voltage Measurement... 12:40:43 Voltage Offset Correction: v_off_ini = 102.504 uV, v_off_fin = 104.321 uV 12:40:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.920 uVs 12:40:44 Integrated Voltage Measurement... 12:40:53 Voltage Offset Correction: v_off_ini = 75.117 uV, v_off_fin = 65.747 uV 12:40:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.498 uVs 12:40:53 Integrated Voltage Measurement... 12:41:02 Voltage Offset Correction: v_off_ini = 83.705 uV, v_off_fin = 86.432 uV 12:41:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.292 uVs 12:41:02 Integrated Voltage Measurement... 12:41:11 Voltage Offset Correction: v_off_ini = 109.997 uV, v_off_fin = 105.679 uV 12:41:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.640 uVs 12:41:11 Integrated Voltage Measurement... 12:41:20 Voltage Offset Correction: v_off_ini = 107.947 uV, v_off_fin = 114.796 uV 12:41:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.063 uVs 12:41:22 I2X Average and RMS of Measurements VT = -100.346 +- 2.900 uVs I2X = 9.232 +- 0.267 uTm^2 12:41:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:41:30 Integrated Voltage Measurement... 12:41:39 Voltage Offset Correction: v_off_ini = 115.137 uV, v_off_fin = 100.758 uV 12:41:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.223 uVs 12:41:39 Integrated Voltage Measurement... 12:41:48 Voltage Offset Correction: v_off_ini = 111.261 uV, v_off_fin = 112.188 uV 12:41:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.193 uVs 12:41:48 Integrated Voltage Measurement... 12:41:57 Voltage Offset Correction: v_off_ini = 80.766 uV, v_off_fin = 92.028 uV 12:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.660 uVs 12:41:57 Integrated Voltage Measurement... 12:42:06 Voltage Offset Correction: v_off_ini = 109.784 uV, v_off_fin = 122.547 uV 12:42:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.368 uVs 12:42:06 Integrated Voltage Measurement... 12:42:15 Voltage Offset Correction: v_off_ini = 115.321 uV, v_off_fin = 115.196 uV 12:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.641 uVs 12:42:15 Integrated Voltage Measurement... 12:42:24 Voltage Offset Correction: v_off_ini = 112.906 uV, v_off_fin = 102.278 uV 12:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.347 uVs 12:42:26 I2Y Average and RMS of Measurements VT = -282.405 +- 3.529 uVs I2Y = -25.981 +- 0.325 uTm^2 12:42:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:42:35 Integrated Voltage Measurement... 12:42:44 Voltage Offset Correction: v_off_ini = 107.595 uV, v_off_fin = 107.283 uV 12:42:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.921 uVs 12:42:44 Integrated Voltage Measurement... 12:42:53 Voltage Offset Correction: v_off_ini = 118.311 uV, v_off_fin = 114.297 uV 12:42:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.387 uVs 12:42:53 Integrated Voltage Measurement... 12:43:02 Voltage Offset Correction: v_off_ini = 132.318 uV, v_off_fin = 134.615 uV 12:43:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.199 uVs 12:43:02 Integrated Voltage Measurement... 12:43:11 Voltage Offset Correction: v_off_ini = 154.695 uV, v_off_fin = 132.147 uV 12:43:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.220 uVs 12:43:11 Integrated Voltage Measurement... 12:43:20 Voltage Offset Correction: v_off_ini = 120.361 uV, v_off_fin = 122.691 uV 12:43:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.759 uVs 12:43:20 Integrated Voltage Measurement... 12:43:29 Voltage Offset Correction: v_off_ini = 130.953 uV, v_off_fin = 135.351 uV 12:43:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.641 uVs 12:43:34 I1X Average and RMS of Measurements VT = -82.854 +- 4.657 uVs I1X = 16.571 +- 0.931 uTm 12:43:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:43:40 Integrated Voltage Measurement... 12:43:49 Voltage Offset Correction: v_off_ini = 130.053 uV, v_off_fin = 134.004 uV 12:43:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.147 uVs 12:43:49 Integrated Voltage Measurement... 12:43:58 Voltage Offset Correction: v_off_ini = 143.887 uV, v_off_fin = 140.130 uV 12:43:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.672 uVs 12:43:59 Integrated Voltage Measurement... 12:44:07 Voltage Offset Correction: v_off_ini = 150.928 uV, v_off_fin = 137.104 uV 12:44:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.623 uVs 12:44:08 Integrated Voltage Measurement... 12:44:16 Voltage Offset Correction: v_off_ini = 155.221 uV, v_off_fin = 165.855 uV 12:44:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.733 uVs 12:44:17 Integrated Voltage Measurement... 12:44:25 Voltage Offset Correction: v_off_ini = 150.609 uV, v_off_fin = 136.785 uV 12:44:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.834 uVs 12:44:26 Integrated Voltage Measurement... 12:44:34 Voltage Offset Correction: v_off_ini = 159.049 uV, v_off_fin = 155.677 uV 12:44:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.034 uVs 12:44:39 I1Y Average and RMS of Measurements VT = -189.674 +- 2.893 uVs I1Y = -37.935 +- 0.579 uTm 12:44:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:44:46 Integrated Voltage Measurement... 12:44:55 Voltage Offset Correction: v_off_ini = 164.635 uV, v_off_fin = 152.132 uV 12:44:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.458 uVs 12:44:55 Integrated Voltage Measurement... 12:45:04 Voltage Offset Correction: v_off_ini = 159.621 uV, v_off_fin = 154.004 uV 12:45:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.599 uVs 12:45:05 Integrated Voltage Measurement... 12:45:13 Voltage Offset Correction: v_off_ini = 160.935 uV, v_off_fin = 138.996 uV 12:45:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.403 uVs 12:45:14 Integrated Voltage Measurement... 12:45:23 Voltage Offset Correction: v_off_ini = 152.037 uV, v_off_fin = 159.155 uV 12:45:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.798 uVs 12:45:23 Integrated Voltage Measurement... 12:45:32 Voltage Offset Correction: v_off_ini = 167.180 uV, v_off_fin = 155.927 uV 12:45:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.868 uVs 12:45:32 Integrated Voltage Measurement... 12:45:41 Voltage Offset Correction: v_off_ini = 141.498 uV, v_off_fin = 145.567 uV 12:45:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.249 uVs 12:45:43 I2X Average and RMS of Measurements VT = -97.562 +- 10.038 uVs I2X = 8.976 +- 0.923 uTm^2 12:45:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:45:51 Integrated Voltage Measurement... 12:46:00 Voltage Offset Correction: v_off_ini = 162.515 uV, v_off_fin = 158.648 uV 12:46:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.622 uVs 12:46:00 Integrated Voltage Measurement... 12:46:09 Voltage Offset Correction: v_off_ini = 158.334 uV, v_off_fin = 160.579 uV 12:46:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.826 uVs 12:46:09 Integrated Voltage Measurement... 12:46:18 Voltage Offset Correction: v_off_ini = 155.447 uV, v_off_fin = 154.382 uV 12:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.422 uVs 12:46:18 Integrated Voltage Measurement... 12:46:27 Voltage Offset Correction: v_off_ini = 152.196 uV, v_off_fin = 158.558 uV 12:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.334 uVs 12:46:27 Integrated Voltage Measurement... 12:46:36 Voltage Offset Correction: v_off_ini = 171.486 uV, v_off_fin = 162.630 uV 12:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.582 uVs 12:46:36 Integrated Voltage Measurement... 12:46:45 Voltage Offset Correction: v_off_ini = 150.193 uV, v_off_fin = 146.206 uV 12:46:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.593 uVs 12:46:47 I2Y Average and RMS of Measurements VT = -262.896 +- 1.781 uVs I2Y = -24.186 +- 0.164 uTm^2 12:46:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:46:56 Integrated Voltage Measurement... 12:47:05 Voltage Offset Correction: v_off_ini = 170.618 uV, v_off_fin = 163.820 uV 12:47:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -47.239 uVs 12:47:05 Integrated Voltage Measurement... 12:47:14 Voltage Offset Correction: v_off_ini = 150.992 uV, v_off_fin = 162.504 uV 12:47:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.203 uVs 12:47:14 Integrated Voltage Measurement... 12:47:23 Voltage Offset Correction: v_off_ini = 145.282 uV, v_off_fin = 149.978 uV 12:47:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.931 uVs 12:47:23 Integrated Voltage Measurement... 12:47:32 Voltage Offset Correction: v_off_ini = 161.738 uV, v_off_fin = 141.659 uV 12:47:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.449 uVs 12:47:32 Integrated Voltage Measurement... 12:47:41 Voltage Offset Correction: v_off_ini = 154.883 uV, v_off_fin = 155.062 uV 12:47:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.614 uVs 12:47:41 Integrated Voltage Measurement... 12:47:50 Voltage Offset Correction: v_off_ini = 163.063 uV, v_off_fin = 155.736 uV 12:47:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.382 uVs 12:47:55 I1X Average and RMS of Measurements VT = -65.303 +- 6.111 uVs I1X = 13.061 +- 1.222 uTm 12:47:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:48:01 Integrated Voltage Measurement... 12:48:10 Voltage Offset Correction: v_off_ini = 145.140 uV, v_off_fin = 150.626 uV 12:48:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.695 uVs 12:48:10 Integrated Voltage Measurement... 12:48:19 Voltage Offset Correction: v_off_ini = 170.288 uV, v_off_fin = 173.522 uV 12:48:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.910 uVs 12:48:19 Integrated Voltage Measurement... 12:48:28 Voltage Offset Correction: v_off_ini = 165.281 uV, v_off_fin = 162.374 uV 12:48:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.656 uVs 12:48:28 Integrated Voltage Measurement... 12:48:37 Voltage Offset Correction: v_off_ini = 163.224 uV, v_off_fin = 145.856 uV 12:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.473 uVs 12:48:37 Integrated Voltage Measurement... 12:48:46 Voltage Offset Correction: v_off_ini = 163.433 uV, v_off_fin = 155.163 uV 12:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.497 uVs 12:48:46 Integrated Voltage Measurement... 12:48:55 Voltage Offset Correction: v_off_ini = 157.829 uV, v_off_fin = 159.799 uV 12:48:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.784 uVs 12:49:00 I1Y Average and RMS of Measurements VT = -185.836 +- 2.357 uVs I1Y = -37.167 +- 0.471 uTm 12:49:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:49:07 Integrated Voltage Measurement... 12:49:16 Voltage Offset Correction: v_off_ini = 163.766 uV, v_off_fin = 164.453 uV 12:49:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.511 uVs 12:49:16 Integrated Voltage Measurement... 12:49:25 Voltage Offset Correction: v_off_ini = 156.483 uV, v_off_fin = 143.480 uV 12:49:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.792 uVs 12:49:25 Integrated Voltage Measurement... 12:49:34 Voltage Offset Correction: v_off_ini = 148.693 uV, v_off_fin = 145.598 uV 12:49:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.857 uVs 12:49:34 Integrated Voltage Measurement... 12:49:43 Voltage Offset Correction: v_off_ini = 152.831 uV, v_off_fin = 156.614 uV 12:49:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.645 uVs 12:49:43 Integrated Voltage Measurement... 12:49:52 Voltage Offset Correction: v_off_ini = 136.579 uV, v_off_fin = 130.725 uV 12:49:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.864 uVs 12:49:52 Integrated Voltage Measurement... 12:50:01 Voltage Offset Correction: v_off_ini = 125.201 uV, v_off_fin = 124.301 uV 12:50:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.879 uVs 12:50:04 I2X Average and RMS of Measurements VT = -92.091 +- 1.334 uVs I2X = 8.472 +- 0.123 uTm^2 12:50:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:50:12 Integrated Voltage Measurement... 12:50:21 Voltage Offset Correction: v_off_ini = 145.448 uV, v_off_fin = 133.958 uV 12:50:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.925 uVs 12:50:21 Integrated Voltage Measurement... 12:50:30 Voltage Offset Correction: v_off_ini = 138.535 uV, v_off_fin = 139.115 uV 12:50:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.150 uVs 12:50:30 Integrated Voltage Measurement... 12:50:39 Voltage Offset Correction: v_off_ini = 138.110 uV, v_off_fin = 152.126 uV 12:50:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.811 uVs 12:50:39 Integrated Voltage Measurement... 12:50:48 Voltage Offset Correction: v_off_ini = 161.984 uV, v_off_fin = 150.439 uV 12:50:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.560 uVs 12:50:48 Integrated Voltage Measurement... 12:50:57 Voltage Offset Correction: v_off_ini = 166.576 uV, v_off_fin = 154.314 uV 12:50:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.254 uVs 12:50:57 Integrated Voltage Measurement... 12:51:06 Voltage Offset Correction: v_off_ini = 118.475 uV, v_off_fin = 154.462 uV 12:51:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.237 uVs 12:51:08 I2Y Average and RMS of Measurements VT = -252.490 +- 8.271 uVs I2Y = -23.229 +- 0.761 uTm^2 12:51:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:51:20 Integrated Voltage Measurement... 12:51:29 Voltage Offset Correction: v_off_ini = 173.607 uV, v_off_fin = 166.863 uV 12:51:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.200 uVs 12:51:29 Integrated Voltage Measurement... 12:51:38 Voltage Offset Correction: v_off_ini = 150.694 uV, v_off_fin = 173.579 uV 12:51:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.774 uVs 12:51:38 Integrated Voltage Measurement... 12:51:47 Voltage Offset Correction: v_off_ini = 179.665 uV, v_off_fin = 168.405 uV 12:51:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.158 uVs 12:51:47 Integrated Voltage Measurement... 12:51:56 Voltage Offset Correction: v_off_ini = 184.546 uV, v_off_fin = 192.083 uV 12:51:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.958 uVs 12:51:56 Integrated Voltage Measurement... 12:52:05 Voltage Offset Correction: v_off_ini = 186.822 uV, v_off_fin = 198.316 uV 12:52:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.425 uVs 12:52:05 Integrated Voltage Measurement... 12:52:14 Voltage Offset Correction: v_off_ini = 206.156 uV, v_off_fin = 176.550 uV 12:52:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.088 uVs 12:52:18 I1X Average and RMS of Measurements VT = -75.934 +- 16.985 uVs I1X = 15.187 +- 3.397 uTm 12:52:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:52:25 Integrated Voltage Measurement... 12:52:34 Voltage Offset Correction: v_off_ini = 205.231 uV, v_off_fin = 198.930 uV 12:52:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.475 uVs 12:52:34 Integrated Voltage Measurement... 12:52:43 Voltage Offset Correction: v_off_ini = 201.948 uV, v_off_fin = 206.723 uV 12:52:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.755 uVs 12:52:43 Integrated Voltage Measurement... 12:52:52 Voltage Offset Correction: v_off_ini = 189.798 uV, v_off_fin = 200.049 uV 12:52:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.560 uVs 12:52:52 Integrated Voltage Measurement... 12:53:01 Voltage Offset Correction: v_off_ini = 212.919 uV, v_off_fin = 192.576 uV 12:53:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.895 uVs 12:53:01 Integrated Voltage Measurement... 12:53:10 Voltage Offset Correction: v_off_ini = 211.134 uV, v_off_fin = 200.251 uV 12:53:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.581 uVs 12:53:10 Integrated Voltage Measurement... 12:53:19 Voltage Offset Correction: v_off_ini = 214.118 uV, v_off_fin = 227.977 uV 12:53:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.848 uVs 12:53:23 I1Y Average and RMS of Measurements VT = -197.019 +- 4.430 uVs I1Y = -39.404 +- 0.886 uTm 12:53:26 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:53:28 Integrated Voltage Measurement... 12:53:37 Voltage Offset Correction: v_off_ini = 230.689 uV, v_off_fin = 215.756 uV 12:53:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.856 uVs 12:53:37 Integrated Voltage Measurement... 12:53:46 Voltage Offset Correction: v_off_ini = 214.888 uV, v_off_fin = 215.606 uV 12:53:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.343 uVs 12:53:46 Integrated Voltage Measurement... 12:53:55 Voltage Offset Correction: v_off_ini = 202.811 uV, v_off_fin = 211.928 uV 12:53:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.083 uVs 12:53:56 Integrated Voltage Measurement... 12:54:05 Voltage Offset Correction: v_off_ini = 206.439 uV, v_off_fin = 212.673 uV 12:54:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.616 uVs 12:54:05 Integrated Voltage Measurement... 12:54:14 Voltage Offset Correction: v_off_ini = 205.953 uV, v_off_fin = 194.447 uV 12:54:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.671 uVs 12:54:14 Integrated Voltage Measurement... 12:54:23 Voltage Offset Correction: v_off_ini = 198.163 uV, v_off_fin = 215.018 uV 12:54:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.358 uVs 12:54:25 I2X Average and RMS of Measurements VT = -85.821 +- 10.078 uVs I2X = 7.896 +- 0.927 uTm^2 12:54:27 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:54:30 Integrated Voltage Measurement... 12:54:39 Voltage Offset Correction: v_off_ini = 198.666 uV, v_off_fin = 205.281 uV 12:54:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.132 uVs 12:54:39 Integrated Voltage Measurement... 12:54:48 Voltage Offset Correction: v_off_ini = 215.253 uV, v_off_fin = 214.263 uV 12:54:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.221 uVs 12:54:48 Integrated Voltage Measurement... 12:54:57 Voltage Offset Correction: v_off_ini = 216.728 uV, v_off_fin = 195.818 uV 12:54:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.897 uVs 12:54:57 Integrated Voltage Measurement... 12:55:06 Voltage Offset Correction: v_off_ini = 211.692 uV, v_off_fin = 191.722 uV 12:55:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.436 uVs 12:55:06 Integrated Voltage Measurement... 12:55:15 Voltage Offset Correction: v_off_ini = 204.142 uV, v_off_fin = 213.577 uV 12:55:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.353 uVs 12:55:15 Integrated Voltage Measurement... 12:55:24 Voltage Offset Correction: v_off_ini = 200.319 uV, v_off_fin = 205.448 uV 12:55:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.725 uVs 12:55:27 I2Y Average and RMS of Measurements VT = -273.294 +- 3.752 uVs I2Y = -25.143 +- 0.345 uTm^2 12:55:31 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:55:35 Integrated Voltage Measurement... 12:55:44 Voltage Offset Correction: v_off_ini = 185.530 uV, v_off_fin = 190.603 uV 12:55:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -54.186 uVs 12:55:44 Integrated Voltage Measurement... 12:55:53 Voltage Offset Correction: v_off_ini = 181.184 uV, v_off_fin = 202.369 uV 12:55:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.701 uVs 12:55:53 Integrated Voltage Measurement... 12:56:02 Voltage Offset Correction: v_off_ini = 208.887 uV, v_off_fin = 196.308 uV 12:56:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.746 uVs 12:56:02 Integrated Voltage Measurement... 12:56:11 Voltage Offset Correction: v_off_ini = 198.008 uV, v_off_fin = 194.189 uV 12:56:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.554 uVs 12:56:11 Integrated Voltage Measurement... 12:56:20 Voltage Offset Correction: v_off_ini = 178.940 uV, v_off_fin = 189.304 uV 12:56:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.677 uVs 12:56:20 Integrated Voltage Measurement... 12:56:29 Voltage Offset Correction: v_off_ini = 213.338 uV, v_off_fin = 212.529 uV 12:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.985 uVs 12:56:33 I1X Average and RMS of Measurements VT = -64.642 +- 6.499 uVs I1X = 12.928 +- 1.300 uTm 12:56:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:56:40 Integrated Voltage Measurement... 12:56:49 Voltage Offset Correction: v_off_ini = 201.320 uV, v_off_fin = 193.409 uV 12:56:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.879 uVs 12:56:49 Integrated Voltage Measurement... 12:56:58 Voltage Offset Correction: v_off_ini = 196.753 uV, v_off_fin = 197.335 uV 12:56:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.068 uVs 12:56:58 Integrated Voltage Measurement... 12:57:07 Voltage Offset Correction: v_off_ini = 210.550 uV, v_off_fin = 208.285 uV 12:57:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.707 uVs 12:57:07 Integrated Voltage Measurement... 12:57:16 Voltage Offset Correction: v_off_ini = 203.745 uV, v_off_fin = 229.456 uV 12:57:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.886 uVs 12:57:16 Integrated Voltage Measurement... 12:57:25 Voltage Offset Correction: v_off_ini = 200.778 uV, v_off_fin = 187.720 uV 12:57:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.597 uVs 12:57:25 Integrated Voltage Measurement... 12:57:34 Voltage Offset Correction: v_off_ini = 185.682 uV, v_off_fin = 200.913 uV 12:57:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.431 uVs 12:57:38 I1Y Average and RMS of Measurements VT = -201.761 +- 7.040 uVs I1Y = -40.352 +- 1.408 uTm 12:57:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:57:43 Integrated Voltage Measurement... 12:57:52 Voltage Offset Correction: v_off_ini = 201.088 uV, v_off_fin = 192.537 uV 12:57:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.117 uVs 12:57:52 Integrated Voltage Measurement... 12:58:01 Voltage Offset Correction: v_off_ini = 219.768 uV, v_off_fin = 216.597 uV 12:58:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.189 uVs 12:58:01 Integrated Voltage Measurement... 12:58:10 Voltage Offset Correction: v_off_ini = 224.775 uV, v_off_fin = 214.756 uV 12:58:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.436 uVs 12:58:10 Integrated Voltage Measurement... 12:58:19 Voltage Offset Correction: v_off_ini = 213.887 uV, v_off_fin = 209.955 uV 12:58:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.023 uVs 12:58:19 Integrated Voltage Measurement... 12:58:28 Voltage Offset Correction: v_off_ini = 203.925 uV, v_off_fin = 180.538 uV 12:58:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.284 uVs 12:58:28 Integrated Voltage Measurement... 12:58:37 Voltage Offset Correction: v_off_ini = 198.912 uV, v_off_fin = 210.230 uV 12:58:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.978 uVs 12:58:40 I2X Average and RMS of Measurements VT = -87.838 +- 2.373 uVs I2X = 8.081 +- 0.218 uTm^2 12:58:42 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:58:45 Integrated Voltage Measurement... 12:58:54 Voltage Offset Correction: v_off_ini = 207.334 uV, v_off_fin = 208.780 uV 12:58:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.202 uVs 12:58:54 Integrated Voltage Measurement... 12:59:03 Voltage Offset Correction: v_off_ini = 212.811 uV, v_off_fin = 216.059 uV 12:59:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.169 uVs 12:59:03 Integrated Voltage Measurement... 12:59:12 Voltage Offset Correction: v_off_ini = 225.979 uV, v_off_fin = 225.049 uV 12:59:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.025 uVs 12:59:12 Integrated Voltage Measurement... 12:59:21 Voltage Offset Correction: v_off_ini = 218.104 uV, v_off_fin = 228.964 uV 12:59:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.206 uVs 12:59:21 Integrated Voltage Measurement... 12:59:30 Voltage Offset Correction: v_off_ini = 239.953 uV, v_off_fin = 243.053 uV 12:59:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.414 uVs 12:59:30 Integrated Voltage Measurement... 12:59:39 Voltage Offset Correction: v_off_ini = 240.951 uV, v_off_fin = 224.727 uV 12:59:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.203 uVs 12:59:42 I2Y Average and RMS of Measurements VT = -273.870 +- 13.339 uVs I2Y = -25.196 +- 1.227 uTm^2 12:59:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:59:50 Integrated Voltage Measurement... 12:59:59 Voltage Offset Correction: v_off_ini = 233.186 uV, v_off_fin = 223.809 uV 12:59:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -56.757 uVs 12:59:59 Integrated Voltage Measurement... 13:00:08 Voltage Offset Correction: v_off_ini = 225.678 uV, v_off_fin = 235.161 uV 13:00:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.349 uVs 13:00:08 Integrated Voltage Measurement... 13:00:17 Voltage Offset Correction: v_off_ini = 243.831 uV, v_off_fin = 250.410 uV 13:00:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.496 uVs 13:00:17 Integrated Voltage Measurement... 13:00:26 Voltage Offset Correction: v_off_ini = 249.680 uV, v_off_fin = 246.132 uV 13:00:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.697 uVs 13:00:26 Integrated Voltage Measurement... 13:00:35 Voltage Offset Correction: v_off_ini = 257.935 uV, v_off_fin = 248.713 uV 13:00:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.363 uVs 13:00:35 Integrated Voltage Measurement... 13:00:44 Voltage Offset Correction: v_off_ini = 223.797 uV, v_off_fin = 255.215 uV 13:00:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.415 uVs 13:00:48 I1X Average and RMS of Measurements VT = -82.846 +- 7.966 uVs I1X = 16.569 +- 1.593 uTm 13:00:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:00:55 Integrated Voltage Measurement... 13:01:04 Voltage Offset Correction: v_off_ini = 241.471 uV, v_off_fin = 229.798 uV 13:01:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -193.625 uVs 13:01:04 Integrated Voltage Measurement... 13:01:13 Voltage Offset Correction: v_off_ini = 252.113 uV, v_off_fin = 268.260 uV 13:01:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.792 uVs 13:01:13 Integrated Voltage Measurement... 13:01:22 Voltage Offset Correction: v_off_ini = 250.242 uV, v_off_fin = 242.820 uV 13:01:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.811 uVs 13:01:22 Integrated Voltage Measurement... 13:01:31 Voltage Offset Correction: v_off_ini = 259.272 uV, v_off_fin = 264.244 uV 13:01:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.193 uVs 13:01:31 Integrated Voltage Measurement... 13:01:40 Voltage Offset Correction: v_off_ini = 257.502 uV, v_off_fin = 245.320 uV 13:01:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.603 uVs 13:01:40 Integrated Voltage Measurement... 13:01:49 Voltage Offset Correction: v_off_ini = 264.800 uV, v_off_fin = 278.972 uV 13:01:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.260 uVs 13:01:53 I1Y Average and RMS of Measurements VT = -196.881 +- 9.160 uVs I1Y = -39.377 +- 1.832 uTm 13:01:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:01:58 Integrated Voltage Measurement... 13:02:07 Voltage Offset Correction: v_off_ini = 271.339 uV, v_off_fin = 248.631 uV 13:02:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.059 uVs 13:02:07 Integrated Voltage Measurement... 13:02:16 Voltage Offset Correction: v_off_ini = 260.742 uV, v_off_fin = 242.627 uV 13:02:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.471 uVs 13:02:16 Integrated Voltage Measurement... 13:02:25 Voltage Offset Correction: v_off_ini = 239.828 uV, v_off_fin = 240.771 uV 13:02:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.104 uVs 13:02:25 Integrated Voltage Measurement... 13:02:34 Voltage Offset Correction: v_off_ini = 251.059 uV, v_off_fin = 263.701 uV 13:02:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.088 uVs 13:02:34 Integrated Voltage Measurement... 13:02:43 Voltage Offset Correction: v_off_ini = 246.150 uV, v_off_fin = 247.921 uV 13:02:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.206 uVs 13:02:43 Integrated Voltage Measurement... 13:02:52 Voltage Offset Correction: v_off_ini = 254.324 uV, v_off_fin = 267.206 uV 13:02:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.636 uVs 13:02:55 I2X Average and RMS of Measurements VT = -91.761 +- 10.970 uVs I2X = 8.442 +- 1.009 uTm^2 13:02:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:03:00 Integrated Voltage Measurement... 13:03:09 Voltage Offset Correction: v_off_ini = 267.429 uV, v_off_fin = 255.485 uV 13:03:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.138 uVs 13:03:09 Integrated Voltage Measurement... 13:03:18 Voltage Offset Correction: v_off_ini = 247.555 uV, v_off_fin = 256.657 uV 13:03:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.387 uVs 13:03:18 Integrated Voltage Measurement... 13:03:27 Voltage Offset Correction: v_off_ini = 260.571 uV, v_off_fin = 250.965 uV 13:03:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.694 uVs 13:03:27 Integrated Voltage Measurement... 13:03:36 Voltage Offset Correction: v_off_ini = 269.026 uV, v_off_fin = 260.988 uV 13:03:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.309 uVs 13:03:36 Integrated Voltage Measurement... 13:03:45 Voltage Offset Correction: v_off_ini = 279.916 uV, v_off_fin = 260.061 uV 13:03:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.350 uVs 13:03:45 Integrated Voltage Measurement... 13:03:54 Voltage Offset Correction: v_off_ini = 274.349 uV, v_off_fin = 263.136 uV 13:03:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.764 uVs 13:03:57 I2Y Average and RMS of Measurements VT = -271.440 +- 11.930 uVs I2Y = -24.973 +- 1.098 uTm^2 13:04:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:04:05 Integrated Voltage Measurement... 13:04:14 Voltage Offset Correction: v_off_ini = 272.394 uV, v_off_fin = 267.737 uV 13:04:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -46.116 uVs 13:04:14 Integrated Voltage Measurement... 13:04:23 Voltage Offset Correction: v_off_ini = 287.287 uV, v_off_fin = 298.785 uV 13:04:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.007 uVs 13:04:23 Integrated Voltage Measurement... 13:04:32 Voltage Offset Correction: v_off_ini = 291.217 uV, v_off_fin = 293.287 uV 13:04:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.276 uVs 13:04:32 Integrated Voltage Measurement... 13:04:41 Voltage Offset Correction: v_off_ini = 306.901 uV, v_off_fin = 287.790 uV 13:04:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.479 uVs 13:04:41 Integrated Voltage Measurement... 13:04:50 Voltage Offset Correction: v_off_ini = 292.651 uV, v_off_fin = 284.255 uV 13:04:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.677 uVs 13:04:50 Integrated Voltage Measurement... 13:04:59 Voltage Offset Correction: v_off_ini = 313.833 uV, v_off_fin = 323.681 uV 13:04:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.038 uVs 13:05:03 I1X Average and RMS of Measurements VT = -72.266 +- 15.031 uVs I1X = 14.453 +- 3.006 uTm 13:05:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:05:10 Integrated Voltage Measurement... 13:05:19 Voltage Offset Correction: v_off_ini = 296.437 uV, v_off_fin = 299.551 uV 13:05:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -179.701 uVs 13:05:19 Integrated Voltage Measurement... 13:05:28 Voltage Offset Correction: v_off_ini = 301.577 uV, v_off_fin = 332.965 uV 13:05:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.646 uVs 13:05:28 Integrated Voltage Measurement... 13:05:37 Voltage Offset Correction: v_off_ini = 316.748 uV, v_off_fin = 321.157 uV 13:05:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.917 uVs 13:05:37 Integrated Voltage Measurement... 13:05:46 Voltage Offset Correction: v_off_ini = 311.450 uV, v_off_fin = 329.072 uV 13:05:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.148 uVs 13:05:46 Integrated Voltage Measurement... 13:05:55 Voltage Offset Correction: v_off_ini = 309.449 uV, v_off_fin = 299.855 uV 13:05:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.473 uVs 13:05:55 Integrated Voltage Measurement... 13:06:04 Voltage Offset Correction: v_off_ini = 306.854 uV, v_off_fin = 324.908 uV 13:06:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.108 uVs 13:06:08 I1Y Average and RMS of Measurements VT = -190.332 +- 3.994 uVs I1Y = -38.067 +- 0.799 uTm 13:06:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:06:13 Integrated Voltage Measurement... 13:06:22 Voltage Offset Correction: v_off_ini = 308.089 uV, v_off_fin = 317.475 uV 13:06:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.348 uVs 13:06:22 Integrated Voltage Measurement... 13:06:31 Voltage Offset Correction: v_off_ini = 332.385 uV, v_off_fin = 335.772 uV 13:06:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.043 uVs 13:06:31 Integrated Voltage Measurement... 13:06:40 Voltage Offset Correction: v_off_ini = 322.970 uV, v_off_fin = 292.684 uV 13:06:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.003 uVs 13:06:40 Integrated Voltage Measurement... 13:06:49 Voltage Offset Correction: v_off_ini = 320.228 uV, v_off_fin = 346.276 uV 13:06:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.125 uVs 13:06:49 Integrated Voltage Measurement... 13:06:58 Voltage Offset Correction: v_off_ini = 312.973 uV, v_off_fin = 298.478 uV 13:06:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.689 uVs 13:06:58 Integrated Voltage Measurement... 13:07:07 Voltage Offset Correction: v_off_ini = 306.564 uV, v_off_fin = 306.928 uV 13:07:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.443 uVs 13:07:10 I2X Average and RMS of Measurements VT = -94.442 +- 7.406 uVs I2X = 8.689 +- 0.681 uTm^2 13:07:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:07:15 Integrated Voltage Measurement... 13:07:24 Voltage Offset Correction: v_off_ini = 294.234 uV, v_off_fin = 291.362 uV 13:07:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.758 uVs 13:07:24 Integrated Voltage Measurement... 13:07:33 Voltage Offset Correction: v_off_ini = 292.641 uV, v_off_fin = 283.893 uV 13:07:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.861 uVs 13:07:33 Integrated Voltage Measurement... 13:07:42 Voltage Offset Correction: v_off_ini = 280.852 uV, v_off_fin = 285.194 uV 13:07:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.812 uVs 13:07:42 Integrated Voltage Measurement... 13:07:51 Voltage Offset Correction: v_off_ini = 271.207 uV, v_off_fin = 285.278 uV 13:07:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.508 uVs 13:07:51 Integrated Voltage Measurement... 13:08:00 Voltage Offset Correction: v_off_ini = 288.067 uV, v_off_fin = 293.293 uV 13:08:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.712 uVs 13:08:00 Integrated Voltage Measurement... 13:08:09 Voltage Offset Correction: v_off_ini = 301.656 uV, v_off_fin = 282.381 uV 13:08:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 269.443 uVs 13:08:11 I2Y Average and RMS of Measurements VT = -274.016 +- 4.348 uVs I2Y = -25.210 +- 0.400 uTm^2 13:08:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:08:20 Integrated Voltage Measurement... 13:08:29 Voltage Offset Correction: v_off_ini = 306.533 uV, v_off_fin = 316.160 uV 13:08:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.211 uVs 13:08:29 Integrated Voltage Measurement... 13:08:38 Voltage Offset Correction: v_off_ini = 317.478 uV, v_off_fin = 300.140 uV 13:08:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.099 uVs 13:08:38 Integrated Voltage Measurement... 13:08:47 Voltage Offset Correction: v_off_ini = 292.325 uV, v_off_fin = 302.172 uV 13:08:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.264 uVs 13:08:47 Integrated Voltage Measurement... 13:08:56 Voltage Offset Correction: v_off_ini = 303.781 uV, v_off_fin = 300.895 uV 13:08:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.853 uVs 13:08:56 Integrated Voltage Measurement... 13:09:05 Voltage Offset Correction: v_off_ini = 299.179 uV, v_off_fin = 285.098 uV 13:09:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.916 uVs 13:09:05 Integrated Voltage Measurement... 13:09:14 Voltage Offset Correction: v_off_ini = 295.275 uV, v_off_fin = 295.827 uV 13:09:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.100 uVs 13:09:18 I1X Average and RMS of Measurements VT = -73.740 +- 7.637 uVs I1X = 14.748 +- 1.528 uTm 13:09:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:09:25 Integrated Voltage Measurement... 13:09:34 Voltage Offset Correction: v_off_ini = 304.421 uV, v_off_fin = 308.753 uV 13:09:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -177.701 uVs 13:09:34 Integrated Voltage Measurement... 13:09:43 Voltage Offset Correction: v_off_ini = 303.472 uV, v_off_fin = 325.295 uV 13:09:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.224 uVs 13:09:43 Integrated Voltage Measurement... 13:09:52 Voltage Offset Correction: v_off_ini = 294.997 uV, v_off_fin = 290.002 uV 13:09:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.457 uVs 13:09:52 Integrated Voltage Measurement... 13:10:01 Voltage Offset Correction: v_off_ini = 311.980 uV, v_off_fin = 326.615 uV 13:10:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.047 uVs 13:10:01 Integrated Voltage Measurement... 13:10:10 Voltage Offset Correction: v_off_ini = 319.693 uV, v_off_fin = 310.471 uV 13:10:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.203 uVs 13:10:10 Integrated Voltage Measurement... 13:10:19 Voltage Offset Correction: v_off_ini = 323.175 uV, v_off_fin = 326.932 uV 13:10:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.381 uVs 13:10:23 I1Y Average and RMS of Measurements VT = -189.836 +- 5.777 uVs I1Y = -37.966 +- 1.156 uTm 13:10:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:10:28 Integrated Voltage Measurement... 13:10:37 Voltage Offset Correction: v_off_ini = 316.382 uV, v_off_fin = 316.674 uV 13:10:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.990 uVs 13:10:37 Integrated Voltage Measurement... 13:10:46 Voltage Offset Correction: v_off_ini = 327.751 uV, v_off_fin = 342.425 uV 13:10:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.237 uVs 13:10:46 Integrated Voltage Measurement... 13:10:55 Voltage Offset Correction: v_off_ini = 329.206 uV, v_off_fin = 316.427 uV 13:10:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.214 uVs 13:10:55 Integrated Voltage Measurement... 13:11:04 Voltage Offset Correction: v_off_ini = 334.295 uV, v_off_fin = 348.567 uV 13:11:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.748 uVs 13:11:04 Integrated Voltage Measurement... 13:11:13 Voltage Offset Correction: v_off_ini = 335.778 uV, v_off_fin = 332.317 uV 13:11:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.853 uVs 13:11:13 Integrated Voltage Measurement... 13:11:22 Voltage Offset Correction: v_off_ini = 335.435 uV, v_off_fin = 344.210 uV 13:11:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.536 uVs 13:11:25 I2X Average and RMS of Measurements VT = -93.930 +- 7.598 uVs I2X = 8.642 +- 0.699 uTm^2 13:11:27 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:11:30 Integrated Voltage Measurement... 13:11:39 Voltage Offset Correction: v_off_ini = 352.538 uV, v_off_fin = 340.513 uV 13:11:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.512 uVs 13:11:39 Integrated Voltage Measurement... 13:11:48 Voltage Offset Correction: v_off_ini = 348.138 uV, v_off_fin = 346.964 uV 13:11:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.665 uVs 13:11:48 Integrated Voltage Measurement... 13:11:57 Voltage Offset Correction: v_off_ini = 342.190 uV, v_off_fin = 327.073 uV 13:11:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.361 uVs 13:11:57 Integrated Voltage Measurement... 13:12:06 Voltage Offset Correction: v_off_ini = 313.250 uV, v_off_fin = 330.236 uV 13:12:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.436 uVs 13:12:06 Integrated Voltage Measurement... 13:12:15 Voltage Offset Correction: v_off_ini = 327.714 uV, v_off_fin = 327.717 uV 13:12:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.315 uVs 13:12:15 Integrated Voltage Measurement... 13:12:24 Voltage Offset Correction: v_off_ini = 336.918 uV, v_off_fin = 318.504 uV 13:12:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.108 uVs 13:12:26 I2Y Average and RMS of Measurements VT = -265.733 +- 7.089 uVs I2Y = -24.447 +- 0.652 uTm^2 13:12:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:12:45 Integrated Voltage Measurement... 13:12:54 Voltage Offset Correction: v_off_ini = 343.595 uV, v_off_fin = 331.914 uV 13:12:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.588 uVs 13:12:54 Integrated Voltage Measurement... 13:13:03 Voltage Offset Correction: v_off_ini = 344.817 uV, v_off_fin = 328.685 uV 13:13:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.769 uVs 13:13:03 Integrated Voltage Measurement... 13:13:12 Voltage Offset Correction: v_off_ini = 336.017 uV, v_off_fin = 318.123 uV 13:13:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.504 uVs 13:13:12 Integrated Voltage Measurement... 13:13:21 Voltage Offset Correction: v_off_ini = 343.384 uV, v_off_fin = 336.871 uV 13:13:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.693 uVs 13:13:21 Integrated Voltage Measurement... 13:13:30 Voltage Offset Correction: v_off_ini = 332.117 uV, v_off_fin = 336.899 uV 13:13:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.241 uVs 13:13:30 Integrated Voltage Measurement... 13:13:39 Voltage Offset Correction: v_off_ini = 333.561 uV, v_off_fin = 329.385 uV 13:13:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.556 uVs 13:13:44 I1X Average and RMS of Measurements VT = -93.392 +- 9.977 uVs I1X = 18.679 +- 1.996 uTm 13:13:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:13:50 Integrated Voltage Measurement... 13:13:59 Voltage Offset Correction: v_off_ini = 336.494 uV, v_off_fin = 325.109 uV 13:13:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.504 uVs 13:13:59 Integrated Voltage Measurement... 13:14:08 Voltage Offset Correction: v_off_ini = 333.379 uV, v_off_fin = 340.756 uV 13:14:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.985 uVs 13:14:08 Integrated Voltage Measurement... 13:14:17 Voltage Offset Correction: v_off_ini = 342.205 uV, v_off_fin = 349.104 uV 13:14:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.593 uVs 13:14:17 Integrated Voltage Measurement... 13:14:26 Voltage Offset Correction: v_off_ini = 350.274 uV, v_off_fin = 355.994 uV 13:14:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.401 uVs 13:14:26 Integrated Voltage Measurement... 13:14:35 Voltage Offset Correction: v_off_ini = 344.727 uV, v_off_fin = 350.716 uV 13:14:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.707 uVs 13:14:35 Integrated Voltage Measurement... 13:14:44 Voltage Offset Correction: v_off_ini = 364.470 uV, v_off_fin = 365.992 uV 13:14:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.138 uVs 13:14:49 I1Y Average and RMS of Measurements VT = -204.055 +- 2.966 uVs I1Y = -40.811 +- 0.593 uTm 13:14:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:14:56 Integrated Voltage Measurement... 13:15:05 Voltage Offset Correction: v_off_ini = 331.559 uV, v_off_fin = 354.046 uV 13:15:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.614 uVs 13:15:05 Integrated Voltage Measurement... 13:15:14 Voltage Offset Correction: v_off_ini = 365.777 uV, v_off_fin = 378.766 uV 13:15:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.483 uVs 13:15:14 Integrated Voltage Measurement... 13:15:23 Voltage Offset Correction: v_off_ini = 375.834 uV, v_off_fin = 373.979 uV 13:15:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.246 uVs 13:15:23 Integrated Voltage Measurement... 13:15:32 Voltage Offset Correction: v_off_ini = 384.828 uV, v_off_fin = 390.850 uV 13:15:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.463 uVs 13:15:33 Integrated Voltage Measurement... 13:15:41 Voltage Offset Correction: v_off_ini = 384.632 uV, v_off_fin = 369.778 uV 13:15:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.160 uVs 13:15:42 Integrated Voltage Measurement... 13:15:51 Voltage Offset Correction: v_off_ini = 351.720 uV, v_off_fin = 390.799 uV 13:15:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.062 uVs 13:15:53 I2X Average and RMS of Measurements VT = -104.505 +- 9.622 uVs I2X = 9.614 +- 0.885 uTm^2 13:15:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:16:01 Integrated Voltage Measurement... 13:16:10 Voltage Offset Correction: v_off_ini = 369.467 uV, v_off_fin = 375.730 uV 13:16:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.958 uVs 13:16:10 Integrated Voltage Measurement... 13:16:19 Voltage Offset Correction: v_off_ini = 371.492 uV, v_off_fin = 337.148 uV 13:16:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.609 uVs 13:16:19 Integrated Voltage Measurement... 13:16:28 Voltage Offset Correction: v_off_ini = 342.499 uV, v_off_fin = 364.830 uV 13:16:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.014 uVs 13:16:28 Integrated Voltage Measurement... 13:16:37 Voltage Offset Correction: v_off_ini = 367.127 uV, v_off_fin = 354.674 uV 13:16:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.159 uVs 13:16:37 Integrated Voltage Measurement... 13:16:46 Voltage Offset Correction: v_off_ini = 372.726 uV, v_off_fin = 363.890 uV 13:16:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.833 uVs 13:16:46 Integrated Voltage Measurement... 13:16:55 Voltage Offset Correction: v_off_ini = 355.710 uV, v_off_fin = 377.883 uV 13:16:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.846 uVs 13:16:57 I2Y Average and RMS of Measurements VT = -288.070 +- 1.951 uVs I2Y = -26.502 +- 0.180 uTm^2 13:17:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:17:06 Integrated Voltage Measurement... 13:17:15 Voltage Offset Correction: v_off_ini = 372.687 uV, v_off_fin = 371.976 uV 13:17:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.983 uVs 13:17:15 Integrated Voltage Measurement... 13:17:24 Voltage Offset Correction: v_off_ini = 362.129 uV, v_off_fin = 367.901 uV 13:17:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.606 uVs 13:17:24 Integrated Voltage Measurement... 13:17:33 Voltage Offset Correction: v_off_ini = 362.532 uV, v_off_fin = 351.133 uV 13:17:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.561 uVs 13:17:33 Integrated Voltage Measurement... 13:17:42 Voltage Offset Correction: v_off_ini = 356.326 uV, v_off_fin = 366.181 uV 13:17:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 85.603 uVs 13:17:42 Integrated Voltage Measurement... 13:17:51 Voltage Offset Correction: v_off_ini = 367.682 uV, v_off_fin = 375.193 uV 13:17:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.540 uVs 13:17:51 Integrated Voltage Measurement... 13:18:00 Voltage Offset Correction: v_off_ini = 335.955 uV, v_off_fin = 349.067 uV 13:18:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.663 uVs 13:18:05 I1X Average and RMS of Measurements VT = -87.326 +- 2.021 uVs I1X = 17.466 +- 0.405 uTm 13:18:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:18:11 Integrated Voltage Measurement... 13:18:20 Voltage Offset Correction: v_off_ini = 372.084 uV, v_off_fin = 364.923 uV 13:18:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.928 uVs 13:18:20 Integrated Voltage Measurement... 13:18:29 Voltage Offset Correction: v_off_ini = 360.535 uV, v_off_fin = 363.026 uV 13:18:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.859 uVs 13:18:29 Integrated Voltage Measurement... 13:18:38 Voltage Offset Correction: v_off_ini = 361.381 uV, v_off_fin = 334.949 uV 13:18:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.842 uVs 13:18:38 Integrated Voltage Measurement... 13:18:47 Voltage Offset Correction: v_off_ini = 356.899 uV, v_off_fin = 374.378 uV 13:18:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.004 uVs 13:18:47 Integrated Voltage Measurement... 13:18:56 Voltage Offset Correction: v_off_ini = 377.157 uV, v_off_fin = 360.697 uV 13:18:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.042 uVs 13:18:56 Integrated Voltage Measurement... 13:19:05 Voltage Offset Correction: v_off_ini = 372.392 uV, v_off_fin = 365.316 uV 13:19:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.551 uVs 13:19:10 I1Y Average and RMS of Measurements VT = -200.538 +- 2.527 uVs I1Y = -40.108 +- 0.505 uTm 13:19:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:19:17 Integrated Voltage Measurement... 13:19:26 Voltage Offset Correction: v_off_ini = 351.210 uV, v_off_fin = 335.748 uV 13:19:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -142.572 uVs 13:19:26 Integrated Voltage Measurement... 13:19:35 Voltage Offset Correction: v_off_ini = 338.612 uV, v_off_fin = 346.706 uV 13:19:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.581 uVs 13:19:35 Integrated Voltage Measurement... 13:19:44 Voltage Offset Correction: v_off_ini = 360.673 uV, v_off_fin = 355.873 uV 13:19:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.408 uVs 13:19:44 Integrated Voltage Measurement... 13:19:53 Voltage Offset Correction: v_off_ini = 365.618 uV, v_off_fin = 374.917 uV 13:19:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.872 uVs 13:19:53 Integrated Voltage Measurement... 13:20:02 Voltage Offset Correction: v_off_ini = 353.914 uV, v_off_fin = 344.848 uV 13:20:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.755 uVs 13:20:02 Integrated Voltage Measurement... 13:20:11 Voltage Offset Correction: v_off_ini = 359.271 uV, v_off_fin = 364.891 uV 13:20:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 86.304 uVs 13:20:14 I2X Average and RMS of Measurements VT = -109.415 +- 6.185 uVs I2X = 10.066 +- 0.569 uTm^2 13:20:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:20:22 Integrated Voltage Measurement... 13:20:31 Voltage Offset Correction: v_off_ini = 371.191 uV, v_off_fin = 366.885 uV 13:20:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.374 uVs 13:20:31 Integrated Voltage Measurement... 13:20:40 Voltage Offset Correction: v_off_ini = 341.330 uV, v_off_fin = 359.089 uV 13:20:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.833 uVs 13:20:40 Integrated Voltage Measurement... 13:20:49 Voltage Offset Correction: v_off_ini = 355.699 uV, v_off_fin = 350.987 uV 13:20:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.678 uVs 13:20:49 Integrated Voltage Measurement... 13:20:58 Voltage Offset Correction: v_off_ini = 347.197 uV, v_off_fin = 350.149 uV 13:20:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.518 uVs 13:20:58 Integrated Voltage Measurement... 13:21:07 Voltage Offset Correction: v_off_ini = 382.417 uV, v_off_fin = 383.868 uV 13:21:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.841 uVs 13:21:07 Integrated Voltage Measurement... 13:21:16 Voltage Offset Correction: v_off_ini = 371.893 uV, v_off_fin = 379.042 uV 13:21:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.113 uVs 13:21:18 I2Y Average and RMS of Measurements VT = -279.226 +- 4.382 uVs I2Y = -25.689 +- 0.403 uTm^2 13:21:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:21:27 Integrated Voltage Measurement... 13:21:36 Voltage Offset Correction: v_off_ini = 380.702 uV, v_off_fin = 358.260 uV 13:21:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.285 uVs 13:21:36 Integrated Voltage Measurement... 13:21:45 Voltage Offset Correction: v_off_ini = 357.216 uV, v_off_fin = 361.351 uV 13:21:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.260 uVs 13:21:45 Integrated Voltage Measurement... 13:21:54 Voltage Offset Correction: v_off_ini = 361.484 uV, v_off_fin = 380.002 uV 13:21:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.312 uVs 13:21:54 Integrated Voltage Measurement... 13:22:03 Voltage Offset Correction: v_off_ini = 391.867 uV, v_off_fin = 381.410 uV 13:22:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.021 uVs 13:22:03 Integrated Voltage Measurement... 13:22:12 Voltage Offset Correction: v_off_ini = 398.846 uV, v_off_fin = 393.302 uV 13:22:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.173 uVs 13:22:12 Integrated Voltage Measurement... 13:22:21 Voltage Offset Correction: v_off_ini = 394.268 uV, v_off_fin = 397.403 uV 13:22:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.139 uVs 13:22:26 I1X Average and RMS of Measurements VT = -78.365 +- 14.249 uVs I1X = 15.673 +- 2.850 uTm 13:22:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:22:32 Integrated Voltage Measurement... 13:22:41 Voltage Offset Correction: v_off_ini = 400.869 uV, v_off_fin = 383.322 uV 13:22:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.315 uVs 13:22:41 Integrated Voltage Measurement... 13:22:50 Voltage Offset Correction: v_off_ini = 410.591 uV, v_off_fin = 428.014 uV 13:22:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.119 uVs 13:22:50 Integrated Voltage Measurement... 13:22:59 Voltage Offset Correction: v_off_ini = 410.480 uV, v_off_fin = 403.542 uV 13:22:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.657 uVs 13:22:59 Integrated Voltage Measurement... 13:23:08 Voltage Offset Correction: v_off_ini = 409.283 uV, v_off_fin = 406.657 uV 13:23:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.322 uVs 13:23:08 Integrated Voltage Measurement... 13:23:17 Voltage Offset Correction: v_off_ini = 413.195 uV, v_off_fin = 441.383 uV 13:23:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.214 uVs 13:23:17 Integrated Voltage Measurement... 13:23:26 Voltage Offset Correction: v_off_ini = 442.251 uV, v_off_fin = 453.204 uV 13:23:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.577 uVs 13:23:31 I1Y Average and RMS of Measurements VT = -189.367 +- 3.999 uVs I1Y = -37.873 +- 0.800 uTm 13:23:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:23:38 Integrated Voltage Measurement... 13:23:47 Voltage Offset Correction: v_off_ini = 421.000 uV, v_off_fin = 419.299 uV 13:23:47 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -93.762 uVs 13:23:47 Integrated Voltage Measurement... 13:23:56 Voltage Offset Correction: v_off_ini = 424.810 uV, v_off_fin = 432.387 uV 13:23:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.971 uVs 13:23:56 Integrated Voltage Measurement... 13:24:05 Voltage Offset Correction: v_off_ini = 409.660 uV, v_off_fin = 416.989 uV 13:24:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.841 uVs 13:24:05 Integrated Voltage Measurement... 13:24:14 Voltage Offset Correction: v_off_ini = 426.163 uV, v_off_fin = 436.760 uV 13:24:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.777 uVs 13:24:14 Integrated Voltage Measurement... 13:24:23 Voltage Offset Correction: v_off_ini = 434.055 uV, v_off_fin = 416.049 uV 13:24:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.477 uVs 13:24:23 Integrated Voltage Measurement... 13:24:32 Voltage Offset Correction: v_off_ini = 431.172 uV, v_off_fin = 434.487 uV 13:24:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 106.547 uVs 13:24:35 I2X Average and RMS of Measurements VT = -96.062 +- 3.572 uVs I2X = 8.838 +- 0.328 uTm^2 13:24:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:24:43 Integrated Voltage Measurement... 13:24:52 Voltage Offset Correction: v_off_ini = 445.601 uV, v_off_fin = 446.956 uV 13:24:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.193 uVs 13:24:52 Integrated Voltage Measurement... 13:25:01 Voltage Offset Correction: v_off_ini = 429.593 uV, v_off_fin = 444.965 uV 13:25:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.416 uVs 13:25:01 Integrated Voltage Measurement... 13:25:10 Voltage Offset Correction: v_off_ini = 446.827 uV, v_off_fin = 446.864 uV 13:25:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.142 uVs 13:25:10 Integrated Voltage Measurement... 13:25:19 Voltage Offset Correction: v_off_ini = 450.232 uV, v_off_fin = 449.702 uV 13:25:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.578 uVs 13:25:19 Integrated Voltage Measurement... 13:25:28 Voltage Offset Correction: v_off_ini = 448.981 uV, v_off_fin = 433.458 uV 13:25:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.731 uVs 13:25:28 Integrated Voltage Measurement... 13:25:37 Voltage Offset Correction: v_off_ini = 442.950 uV, v_off_fin = 439.334 uV 13:25:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.947 uVs 13:25:39 I2Y Average and RMS of Measurements VT = -270.834 +- 6.405 uVs I2Y = -24.917 +- 0.589 uTm^2 13:25:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:25:48 Integrated Voltage Measurement... 13:25:57 Voltage Offset Correction: v_off_ini = 450.893 uV, v_off_fin = 454.783 uV 13:25:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -80.525 uVs 13:25:57 Integrated Voltage Measurement... 13:26:06 Voltage Offset Correction: v_off_ini = 442.766 uV, v_off_fin = 442.456 uV 13:26:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.055 uVs 13:26:06 Integrated Voltage Measurement... 13:26:15 Voltage Offset Correction: v_off_ini = 447.794 uV, v_off_fin = 441.427 uV 13:26:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.554 uVs 13:26:15 Integrated Voltage Measurement... 13:26:24 Voltage Offset Correction: v_off_ini = 413.545 uV, v_off_fin = 438.041 uV 13:26:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.154 uVs 13:26:24 Integrated Voltage Measurement... 13:26:33 Voltage Offset Correction: v_off_ini = 419.412 uV, v_off_fin = 399.525 uV 13:26:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.735 uVs 13:26:33 Integrated Voltage Measurement... 13:26:42 Voltage Offset Correction: v_off_ini = 414.038 uV, v_off_fin = 413.670 uV 13:26:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.142 uVs 13:26:47 I1X Average and RMS of Measurements VT = -68.361 +- 7.162 uVs I1X = 13.673 +- 1.433 uTm 13:26:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:26:53 Integrated Voltage Measurement... 13:27:02 Voltage Offset Correction: v_off_ini = 405.426 uV, v_off_fin = 390.785 uV 13:27:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.166 uVs 13:27:02 Integrated Voltage Measurement... 13:27:11 Voltage Offset Correction: v_off_ini = 380.927 uV, v_off_fin = 383.490 uV 13:27:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.108 uVs 13:27:11 Integrated Voltage Measurement... 13:27:20 Voltage Offset Correction: v_off_ini = 399.585 uV, v_off_fin = 393.495 uV 13:27:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.109 uVs 13:27:20 Integrated Voltage Measurement... 13:27:29 Voltage Offset Correction: v_off_ini = 381.889 uV, v_off_fin = 411.858 uV 13:27:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.737 uVs 13:27:29 Integrated Voltage Measurement... 13:27:38 Voltage Offset Correction: v_off_ini = 391.807 uV, v_off_fin = 385.992 uV 13:27:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.141 uVs 13:27:38 Integrated Voltage Measurement... 13:27:47 Voltage Offset Correction: v_off_ini = 405.205 uV, v_off_fin = 415.722 uV 13:27:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.277 uVs 13:27:52 I1Y Average and RMS of Measurements VT = -191.423 +- 3.399 uVs I1Y = -38.285 +- 0.680 uTm 13:27:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:27:59 Integrated Voltage Measurement... 13:28:08 Voltage Offset Correction: v_off_ini = 389.808 uV, v_off_fin = 379.131 uV 13:28:08 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -64.185 uVs 13:28:08 Integrated Voltage Measurement... 13:28:17 Voltage Offset Correction: v_off_ini = 397.961 uV, v_off_fin = 405.542 uV 13:28:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.547 uVs 13:28:17 Integrated Voltage Measurement... 13:28:26 Voltage Offset Correction: v_off_ini = 395.625 uV, v_off_fin = 391.411 uV 13:28:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.264 uVs 13:28:26 Integrated Voltage Measurement... 13:28:35 Voltage Offset Correction: v_off_ini = 420.921 uV, v_off_fin = 423.590 uV 13:28:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.910 uVs 13:28:35 Integrated Voltage Measurement... 13:28:44 Voltage Offset Correction: v_off_ini = 411.873 uV, v_off_fin = 401.952 uV 13:28:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.961 uVs 13:28:44 Integrated Voltage Measurement... 13:28:53 Voltage Offset Correction: v_off_ini = 420.888 uV, v_off_fin = 432.893 uV 13:28:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.901 uVs 13:28:56 I2X Average and RMS of Measurements VT = -87.795 +- 7.556 uVs I2X = 8.077 +- 0.695 uTm^2 13:29:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:29:04 Integrated Voltage Measurement... 13:29:13 Voltage Offset Correction: v_off_ini = 445.501 uV, v_off_fin = 442.021 uV 13:29:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.001 uVs 13:29:13 Integrated Voltage Measurement... 13:29:22 Voltage Offset Correction: v_off_ini = 438.895 uV, v_off_fin = 429.394 uV 13:29:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.050 uVs 13:29:22 Integrated Voltage Measurement... 13:29:31 Voltage Offset Correction: v_off_ini = 427.672 uV, v_off_fin = 437.728 uV 13:29:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.862 uVs 13:29:31 Integrated Voltage Measurement... 13:29:40 Voltage Offset Correction: v_off_ini = 442.447 uV, v_off_fin = 458.828 uV 13:29:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.152 uVs 13:29:40 Integrated Voltage Measurement... 13:29:49 Voltage Offset Correction: v_off_ini = 452.922 uV, v_off_fin = 444.505 uV 13:29:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.063 uVs 13:29:49 Integrated Voltage Measurement... 13:29:58 Voltage Offset Correction: v_off_ini = 439.575 uV, v_off_fin = 437.665 uV 13:29:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.038 uVs 13:30:00 I2Y Average and RMS of Measurements VT = -254.861 +- 9.818 uVs I2Y = -23.447 +- 0.903 uTm^2 13:30:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:30:09 Integrated Voltage Measurement... 13:30:18 Voltage Offset Correction: v_off_ini = 435.679 uV, v_off_fin = 458.873 uV 13:30:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -64.529 uVs 13:30:18 Integrated Voltage Measurement... 13:30:27 Voltage Offset Correction: v_off_ini = 440.759 uV, v_off_fin = 443.265 uV 13:30:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.556 uVs 13:30:27 Integrated Voltage Measurement... 13:30:36 Voltage Offset Correction: v_off_ini = 444.707 uV, v_off_fin = 438.651 uV 13:30:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.719 uVs 13:30:36 Integrated Voltage Measurement... 13:30:45 Voltage Offset Correction: v_off_ini = 454.872 uV, v_off_fin = 426.705 uV 13:30:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.471 uVs 13:30:45 Integrated Voltage Measurement... 13:30:54 Voltage Offset Correction: v_off_ini = 421.493 uV, v_off_fin = 440.233 uV 13:30:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.518 uVs 13:30:54 Integrated Voltage Measurement... 13:31:03 Voltage Offset Correction: v_off_ini = 420.998 uV, v_off_fin = 436.667 uV 13:31:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.308 uVs 13:31:07 I1X Average and RMS of Measurements VT = -62.350 +- 3.572 uVs I1X = 12.470 +- 0.714 uTm 13:31:10 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:31:14 Integrated Voltage Measurement... 13:31:23 Voltage Offset Correction: v_off_ini = 434.696 uV, v_off_fin = 425.842 uV 13:31:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.446 uVs 13:31:23 Integrated Voltage Measurement... 13:31:32 Voltage Offset Correction: v_off_ini = 412.521 uV, v_off_fin = 433.601 uV 13:31:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.140 uVs 13:31:32 Integrated Voltage Measurement... 13:31:41 Voltage Offset Correction: v_off_ini = 449.914 uV, v_off_fin = 433.748 uV 13:31:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.419 uVs 13:31:41 Integrated Voltage Measurement... 13:31:50 Voltage Offset Correction: v_off_ini = 442.880 uV, v_off_fin = 456.748 uV 13:31:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.885 uVs 13:31:50 Integrated Voltage Measurement... 13:31:59 Voltage Offset Correction: v_off_ini = 436.600 uV, v_off_fin = 438.401 uV 13:31:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.544 uVs 13:31:59 Integrated Voltage Measurement... 13:32:08 Voltage Offset Correction: v_off_ini = 451.376 uV, v_off_fin = 468.025 uV 13:32:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.553 uVs 13:32:12 I1Y Average and RMS of Measurements VT = -177.331 +- 3.736 uVs I1Y = -35.466 +- 0.747 uTm 13:32:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:32:20 Integrated Voltage Measurement... 13:32:29 Voltage Offset Correction: v_off_ini = 449.926 uV, v_off_fin = 436.385 uV 13:32:29 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -71.999 uVs 13:32:29 Integrated Voltage Measurement... 13:32:38 Voltage Offset Correction: v_off_ini = 471.286 uV, v_off_fin = 469.194 uV 13:32:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.006 uVs 13:32:38 Integrated Voltage Measurement... 13:32:47 Voltage Offset Correction: v_off_ini = 448.060 uV, v_off_fin = 457.129 uV 13:32:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.297 uVs 13:32:47 Integrated Voltage Measurement... 13:32:56 Voltage Offset Correction: v_off_ini = 469.740 uV, v_off_fin = 456.043 uV 13:32:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.634 uVs 13:32:56 Integrated Voltage Measurement... 13:33:05 Voltage Offset Correction: v_off_ini = 477.938 uV, v_off_fin = 447.174 uV 13:33:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.930 uVs 13:33:05 Integrated Voltage Measurement... 13:33:14 Voltage Offset Correction: v_off_ini = 457.107 uV, v_off_fin = 451.682 uV 13:33:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.823 uVs 13:33:17 I2X Average and RMS of Measurements VT = -81.281 +- 8.354 uVs I2X = 7.478 +- 0.769 uTm^2 13:33:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:33:24 Integrated Voltage Measurement... 13:33:33 Voltage Offset Correction: v_off_ini = 457.725 uV, v_off_fin = 446.719 uV 13:33:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.281 uVs 13:33:33 Integrated Voltage Measurement... 13:33:42 Voltage Offset Correction: v_off_ini = 420.830 uV, v_off_fin = 423.917 uV 13:33:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.501 uVs 13:33:42 Integrated Voltage Measurement... 13:33:51 Voltage Offset Correction: v_off_ini = 428.771 uV, v_off_fin = 436.954 uV 13:33:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.544 uVs 13:33:51 Integrated Voltage Measurement... 13:34:00 Voltage Offset Correction: v_off_ini = 425.087 uV, v_off_fin = 431.272 uV 13:34:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.747 uVs 13:34:00 Integrated Voltage Measurement... 13:34:09 Voltage Offset Correction: v_off_ini = 437.286 uV, v_off_fin = 442.023 uV 13:34:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.319 uVs 13:34:09 Integrated Voltage Measurement... 13:34:18 Voltage Offset Correction: v_off_ini = 435.476 uV, v_off_fin = 440.567 uV 13:34:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.959 uVs 13:34:21 I2Y Average and RMS of Measurements VT = -236.892 +- 3.375 uVs I2Y = -21.794 +- 0.310 uTm^2 13:34:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:34:33 Integrated Voltage Measurement... 13:34:42 Voltage Offset Correction: v_off_ini = 435.495 uV, v_off_fin = 442.759 uV 13:34:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -61.009 uVs 13:34:42 Integrated Voltage Measurement... 13:34:51 Voltage Offset Correction: v_off_ini = 447.539 uV, v_off_fin = 450.616 uV 13:34:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.477 uVs 13:34:51 Integrated Voltage Measurement... 13:35:00 Voltage Offset Correction: v_off_ini = 441.963 uV, v_off_fin = 449.258 uV 13:35:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.816 uVs 13:35:00 Integrated Voltage Measurement... 13:35:09 Voltage Offset Correction: v_off_ini = 449.972 uV, v_off_fin = 437.713 uV 13:35:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.263 uVs 13:35:09 Integrated Voltage Measurement... 13:35:18 Voltage Offset Correction: v_off_ini = 457.299 uV, v_off_fin = 437.045 uV 13:35:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.045 uVs 13:35:18 Integrated Voltage Measurement... 13:35:27 Voltage Offset Correction: v_off_ini = 436.887 uV, v_off_fin = 442.906 uV 13:35:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.246 uVs 13:35:31 I1X Average and RMS of Measurements VT = -69.976 +- 1.484 uVs I1X = 13.995 +- 0.297 uTm 13:35:33 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:35:38 Integrated Voltage Measurement... 13:35:47 Voltage Offset Correction: v_off_ini = 449.914 uV, v_off_fin = 440.552 uV 13:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.065 uVs 13:35:47 Integrated Voltage Measurement... 13:35:56 Voltage Offset Correction: v_off_ini = 440.184 uV, v_off_fin = 452.005 uV 13:35:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.341 uVs 13:35:56 Integrated Voltage Measurement... 13:36:05 Voltage Offset Correction: v_off_ini = 465.764 uV, v_off_fin = 453.751 uV 13:36:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.250 uVs 13:36:05 Integrated Voltage Measurement... 13:36:14 Voltage Offset Correction: v_off_ini = 455.139 uV, v_off_fin = 470.823 uV 13:36:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.406 uVs 13:36:14 Integrated Voltage Measurement... 13:36:23 Voltage Offset Correction: v_off_ini = 455.088 uV, v_off_fin = 458.906 uV 13:36:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.253 uVs 13:36:23 Integrated Voltage Measurement... 13:36:32 Voltage Offset Correction: v_off_ini = 449.368 uV, v_off_fin = 451.173 uV 13:36:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.935 uVs 13:36:36 I1Y Average and RMS of Measurements VT = -205.042 +- 5.465 uVs I1Y = -41.008 +- 1.093 uTm 13:36:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:36:41 Integrated Voltage Measurement... 13:36:50 Voltage Offset Correction: v_off_ini = 436.619 uV, v_off_fin = 443.911 uV 13:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.165 uVs 13:36:50 Integrated Voltage Measurement... 13:36:59 Voltage Offset Correction: v_off_ini = 465.913 uV, v_off_fin = 472.813 uV 13:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.671 uVs 13:36:59 Integrated Voltage Measurement... 13:37:08 Voltage Offset Correction: v_off_ini = 477.687 uV, v_off_fin = 456.506 uV 13:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.384 uVs 13:37:08 Integrated Voltage Measurement... 13:37:17 Voltage Offset Correction: v_off_ini = 467.912 uV, v_off_fin = 491.177 uV 13:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.916 uVs 13:37:17 Integrated Voltage Measurement... 13:37:26 Voltage Offset Correction: v_off_ini = 476.401 uV, v_off_fin = 474.133 uV 13:37:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.482 uVs 13:37:26 Integrated Voltage Measurement... 13:37:35 Voltage Offset Correction: v_off_ini = 476.234 uV, v_off_fin = 481.297 uV 13:37:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.690 uVs 13:37:37 I2X Average and RMS of Measurements VT = -88.718 +- 1.721 uVs I2X = 8.162 +- 0.158 uTm^2 13:37:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:37:43 Integrated Voltage Measurement... 13:37:52 Voltage Offset Correction: v_off_ini = 473.830 uV, v_off_fin = 478.919 uV 13:37:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.374 uVs 13:37:52 Integrated Voltage Measurement... 13:38:01 Voltage Offset Correction: v_off_ini = 471.386 uV, v_off_fin = 467.912 uV 13:38:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.671 uVs 13:38:01 Integrated Voltage Measurement... 13:38:10 Voltage Offset Correction: v_off_ini = 486.446 uV, v_off_fin = 485.831 uV 13:38:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.456 uVs 13:38:10 Integrated Voltage Measurement... 13:38:19 Voltage Offset Correction: v_off_ini = 481.825 uV, v_off_fin = 492.502 uV 13:38:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.676 uVs 13:38:19 Integrated Voltage Measurement... 13:38:28 Voltage Offset Correction: v_off_ini = 496.936 uV, v_off_fin = 482.652 uV 13:38:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.797 uVs 13:38:28 Integrated Voltage Measurement... 13:38:37 Voltage Offset Correction: v_off_ini = 482.140 uV, v_off_fin = 457.686 uV 13:38:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.042 uVs 13:38:39 I2Y Average and RMS of Measurements VT = -278.003 +- 12.900 uVs I2Y = -25.576 +- 1.187 uTm^2 13:38:43 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:38:47 Integrated Voltage Measurement... 13:38:56 Voltage Offset Correction: v_off_ini = 465.330 uV, v_off_fin = 460.188 uV 13:38:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -74.395 uVs 13:38:56 Integrated Voltage Measurement... 13:39:05 Voltage Offset Correction: v_off_ini = 470.012 uV, v_off_fin = 463.190 uV 13:39:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.432 uVs 13:39:05 Integrated Voltage Measurement... 13:39:14 Voltage Offset Correction: v_off_ini = 446.458 uV, v_off_fin = 465.206 uV 13:39:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.241 uVs 13:39:14 Integrated Voltage Measurement... 13:39:23 Voltage Offset Correction: v_off_ini = 470.510 uV, v_off_fin = 478.842 uV 13:39:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.465 uVs 13:39:23 Integrated Voltage Measurement... 13:39:32 Voltage Offset Correction: v_off_ini = 474.161 uV, v_off_fin = 483.923 uV 13:39:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.767 uVs 13:39:32 Integrated Voltage Measurement... 13:39:41 Voltage Offset Correction: v_off_ini = 480.781 uV, v_off_fin = 480.161 uV 13:39:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.830 uVs 13:39:46 I1X Average and RMS of Measurements VT = -73.022 +- 8.290 uVs I1X = 14.605 +- 1.658 uTm 13:39:48 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:39:52 Integrated Voltage Measurement... 13:40:01 Voltage Offset Correction: v_off_ini = 464.716 uV, v_off_fin = 459.450 uV 13:40:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.217 uVs 13:40:01 Integrated Voltage Measurement... 13:40:10 Voltage Offset Correction: v_off_ini = 459.814 uV, v_off_fin = 468.841 uV 13:40:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.953 uVs 13:40:10 Integrated Voltage Measurement... 13:40:19 Voltage Offset Correction: v_off_ini = 464.000 uV, v_off_fin = 446.886 uV 13:40:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.836 uVs 13:40:19 Integrated Voltage Measurement... 13:40:28 Voltage Offset Correction: v_off_ini = 460.786 uV, v_off_fin = 467.459 uV 13:40:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.940 uVs 13:40:28 Integrated Voltage Measurement... 13:40:37 Voltage Offset Correction: v_off_ini = 473.673 uV, v_off_fin = 471.468 uV 13:40:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.887 uVs 13:40:37 Integrated Voltage Measurement... 13:40:46 Voltage Offset Correction: v_off_ini = 475.864 uV, v_off_fin = 489.113 uV 13:40:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.692 uVs 13:40:50 I1Y Average and RMS of Measurements VT = -193.921 +- 4.909 uVs I1Y = -38.784 +- 0.982 uTm 13:40:53 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:40:55 Integrated Voltage Measurement... 13:41:04 Voltage Offset Correction: v_off_ini = 479.394 uV, v_off_fin = 466.470 uV 13:41:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.422 uVs 13:41:05 Integrated Voltage Measurement... 13:41:13 Voltage Offset Correction: v_off_ini = 469.702 uV, v_off_fin = 470.801 uV 13:41:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.315 uVs 13:41:14 Integrated Voltage Measurement... 13:41:22 Voltage Offset Correction: v_off_ini = 467.562 uV, v_off_fin = 455.055 uV 13:41:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.777 uVs 13:41:23 Integrated Voltage Measurement... 13:41:32 Voltage Offset Correction: v_off_ini = 454.302 uV, v_off_fin = 464.624 uV 13:41:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.044 uVs 13:41:32 Integrated Voltage Measurement... 13:41:41 Voltage Offset Correction: v_off_ini = 452.286 uV, v_off_fin = 439.608 uV 13:41:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.381 uVs 13:41:41 Integrated Voltage Measurement... 13:41:50 Voltage Offset Correction: v_off_ini = 460.300 uV, v_off_fin = 467.217 uV 13:41:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.084 uVs 13:41:52 I2X Average and RMS of Measurements VT = -91.837 +- 6.580 uVs I2X = 8.449 +- 0.605 uTm^2 13:41:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:41:57 Integrated Voltage Measurement... 13:42:06 Voltage Offset Correction: v_off_ini = 459.937 uV, v_off_fin = 450.734 uV 13:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.185 uVs 13:42:06 Integrated Voltage Measurement... 13:42:15 Voltage Offset Correction: v_off_ini = 453.146 uV, v_off_fin = 460.518 uV 13:42:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.016 uVs 13:42:15 Integrated Voltage Measurement... 13:42:24 Voltage Offset Correction: v_off_ini = 466.567 uV, v_off_fin = 454.049 uV 13:42:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.383 uVs 13:42:24 Integrated Voltage Measurement... 13:42:33 Voltage Offset Correction: v_off_ini = 461.407 uV, v_off_fin = 464.207 uV 13:42:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.469 uVs 13:42:33 Integrated Voltage Measurement... 13:42:42 Voltage Offset Correction: v_off_ini = 449.036 uV, v_off_fin = 452.204 uV 13:42:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.104 uVs 13:42:42 Integrated Voltage Measurement... 13:42:51 Voltage Offset Correction: v_off_ini = 455.517 uV, v_off_fin = 450.046 uV 13:42:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.495 uVs 13:42:54 I2Y Average and RMS of Measurements VT = -264.942 +- 9.200 uVs I2Y = -24.375 +- 0.846 uTm^2 13:42:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:43:02 Integrated Voltage Measurement... 13:43:11 Voltage Offset Correction: v_off_ini = 445.933 uV, v_off_fin = 475.104 uV 13:43:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.213 uVs 13:43:11 Integrated Voltage Measurement... 13:43:20 Voltage Offset Correction: v_off_ini = 463.606 uV, v_off_fin = 469.331 uV 13:43:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.874 uVs 13:43:20 Integrated Voltage Measurement... 13:43:29 Voltage Offset Correction: v_off_ini = 464.847 uV, v_off_fin = 464.914 uV 13:43:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.644 uVs 13:43:29 Integrated Voltage Measurement... 13:43:38 Voltage Offset Correction: v_off_ini = 477.140 uV, v_off_fin = 471.205 uV 13:43:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.295 uVs 13:43:38 Integrated Voltage Measurement... 13:43:47 Voltage Offset Correction: v_off_ini = 457.310 uV, v_off_fin = 452.313 uV 13:43:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.513 uVs 13:43:47 Integrated Voltage Measurement... 13:43:56 Voltage Offset Correction: v_off_ini = 460.136 uV, v_off_fin = 443.363 uV 13:43:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 112.133 uVs 13:44:00 I1X Average and RMS of Measurements VT = -85.279 +- 8.674 uVs I1X = 17.057 +- 1.735 uTm 13:44:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:44:07 Integrated Voltage Measurement... 13:44:16 Voltage Offset Correction: v_off_ini = 461.054 uV, v_off_fin = 437.701 uV 13:44:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -188.777 uVs 13:44:16 Integrated Voltage Measurement... 13:44:25 Voltage Offset Correction: v_off_ini = 450.579 uV, v_off_fin = 430.155 uV 13:44:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.210 uVs 13:44:25 Integrated Voltage Measurement... 13:44:34 Voltage Offset Correction: v_off_ini = 433.114 uV, v_off_fin = 435.319 uV 13:44:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.740 uVs 13:44:34 Integrated Voltage Measurement... 13:44:43 Voltage Offset Correction: v_off_ini = 439.620 uV, v_off_fin = 458.378 uV 13:44:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 176.167 uVs 13:44:43 Integrated Voltage Measurement... 13:44:52 Voltage Offset Correction: v_off_ini = 453.994 uV, v_off_fin = 449.266 uV 13:44:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.628 uVs 13:44:52 Integrated Voltage Measurement... 13:45:01 Voltage Offset Correction: v_off_ini = 460.416 uV, v_off_fin = 461.675 uV 13:45:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.194 uVs 13:45:05 I1Y Average and RMS of Measurements VT = -186.286 +- 5.313 uVs I1Y = -37.255 +- 1.063 uTm 13:45:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:10 Integrated Voltage Measurement... 13:45:19 Voltage Offset Correction: v_off_ini = 444.594 uV, v_off_fin = 451.841 uV 13:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.285 uVs 13:45:19 Integrated Voltage Measurement... 13:45:28 Voltage Offset Correction: v_off_ini = 445.772 uV, v_off_fin = 440.106 uV 13:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.046 uVs 13:45:28 Integrated Voltage Measurement... 13:45:37 Voltage Offset Correction: v_off_ini = 452.399 uV, v_off_fin = 450.348 uV 13:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.762 uVs 13:45:37 Integrated Voltage Measurement... 13:45:46 Voltage Offset Correction: v_off_ini = 468.646 uV, v_off_fin = 476.836 uV 13:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.211 uVs 13:45:46 Integrated Voltage Measurement... 13:45:55 Voltage Offset Correction: v_off_ini = 459.960 uV, v_off_fin = 453.927 uV 13:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.288 uVs 13:45:55 Integrated Voltage Measurement... 13:46:04 Voltage Offset Correction: v_off_ini = 469.998 uV, v_off_fin = 469.224 uV 13:46:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.598 uVs 13:46:07 I2X Average and RMS of Measurements VT = -102.199 +- 8.962 uVs I2X = 9.402 +- 0.825 uTm^2 13:46:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:12 Integrated Voltage Measurement... 13:46:21 Voltage Offset Correction: v_off_ini = 482.063 uV, v_off_fin = 473.553 uV 13:46:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.887 uVs 13:46:21 Integrated Voltage Measurement... 13:46:30 Voltage Offset Correction: v_off_ini = 475.995 uV, v_off_fin = 476.493 uV 13:46:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.198 uVs 13:46:30 Integrated Voltage Measurement... 13:46:39 Voltage Offset Correction: v_off_ini = 483.089 uV, v_off_fin = 487.122 uV 13:46:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.894 uVs 13:46:39 Integrated Voltage Measurement... 13:46:48 Voltage Offset Correction: v_off_ini = 496.577 uV, v_off_fin = 485.566 uV 13:46:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.210 uVs 13:46:48 Integrated Voltage Measurement... 13:46:57 Voltage Offset Correction: v_off_ini = 485.165 uV, v_off_fin = 482.500 uV 13:46:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.721 uVs 13:46:57 Integrated Voltage Measurement... 13:47:06 Voltage Offset Correction: v_off_ini = 466.228 uV, v_off_fin = 463.308 uV 13:47:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.322 uVs 13:47:08 I2Y Average and RMS of Measurements VT = -263.706 +- 10.933 uVs I2Y = -24.261 +- 1.006 uTm^2 13:47:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:47:17 Integrated Voltage Measurement... 13:47:26 Voltage Offset Correction: v_off_ini = 466.121 uV, v_off_fin = 472.762 uV 13:47:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.493 uVs 13:47:26 Integrated Voltage Measurement... 13:47:35 Voltage Offset Correction: v_off_ini = 484.082 uV, v_off_fin = 489.440 uV 13:47:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.322 uVs 13:47:35 Integrated Voltage Measurement... 13:47:44 Voltage Offset Correction: v_off_ini = 481.927 uV, v_off_fin = 494.655 uV 13:47:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.999 uVs 13:47:44 Integrated Voltage Measurement... 13:47:53 Voltage Offset Correction: v_off_ini = 510.106 uV, v_off_fin = 500.890 uV 13:47:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.168 uVs 13:47:53 Integrated Voltage Measurement... 13:48:02 Voltage Offset Correction: v_off_ini = 495.375 uV, v_off_fin = 490.326 uV 13:48:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.714 uVs 13:48:02 Integrated Voltage Measurement... 13:48:11 Voltage Offset Correction: v_off_ini = 495.939 uV, v_off_fin = 486.229 uV 13:48:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.995 uVs 13:48:15 I1X Average and RMS of Measurements VT = -73.948 +- 4.870 uVs I1X = 14.790 +- 0.974 uTm 13:48:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:48:22 Integrated Voltage Measurement... 13:48:31 Voltage Offset Correction: v_off_ini = 498.283 uV, v_off_fin = 492.500 uV 13:48:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -169.389 uVs 13:48:31 Integrated Voltage Measurement... 13:48:40 Voltage Offset Correction: v_off_ini = 517.634 uV, v_off_fin = 531.016 uV 13:48:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 179.235 uVs 13:48:40 Integrated Voltage Measurement... 13:48:49 Voltage Offset Correction: v_off_ini = 514.115 uV, v_off_fin = 516.195 uV 13:48:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.791 uVs 13:48:49 Integrated Voltage Measurement... 13:48:58 Voltage Offset Correction: v_off_ini = 524.302 uV, v_off_fin = 533.618 uV 13:48:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.765 uVs 13:48:58 Integrated Voltage Measurement... 13:49:07 Voltage Offset Correction: v_off_ini = 540.228 uV, v_off_fin = 526.561 uV 13:49:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.382 uVs 13:49:07 Integrated Voltage Measurement... 13:49:16 Voltage Offset Correction: v_off_ini = 543.331 uV, v_off_fin = 549.261 uV 13:49:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.338 uVs 13:49:20 I1Y Average and RMS of Measurements VT = -182.483 +- 6.372 uVs I1Y = -36.494 +- 1.273 uTm 13:49:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:49:25 Integrated Voltage Measurement... 13:49:34 Voltage Offset Correction: v_off_ini = 551.066 uV, v_off_fin = 544.316 uV 13:49:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.715 uVs 13:49:34 Integrated Voltage Measurement... 13:49:43 Voltage Offset Correction: v_off_ini = 545.993 uV, v_off_fin = 523.879 uV 13:49:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.787 uVs 13:49:43 Integrated Voltage Measurement... 13:49:52 Voltage Offset Correction: v_off_ini = 535.393 uV, v_off_fin = 533.875 uV 13:49:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.786 uVs 13:49:52 Integrated Voltage Measurement... 13:50:01 Voltage Offset Correction: v_off_ini = 541.175 uV, v_off_fin = 547.211 uV 13:50:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.494 uVs 13:50:01 Integrated Voltage Measurement... 13:50:10 Voltage Offset Correction: v_off_ini = 536.295 uV, v_off_fin = 522.305 uV 13:50:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.712 uVs 13:50:10 Integrated Voltage Measurement... 13:50:19 Voltage Offset Correction: v_off_ini = 535.247 uV, v_off_fin = 538.558 uV 13:50:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.330 uVs 13:50:22 I2X Average and RMS of Measurements VT = -88.971 +- 5.449 uVs I2X = 8.185 +- 0.501 uTm^2 13:50:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:50:27 Integrated Voltage Measurement... 13:50:36 Voltage Offset Correction: v_off_ini = 525.951 uV, v_off_fin = 530.562 uV 13:50:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.910 uVs 13:50:36 Integrated Voltage Measurement... 13:50:45 Voltage Offset Correction: v_off_ini = 511.026 uV, v_off_fin = 526.945 uV 13:50:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.483 uVs 13:50:45 Integrated Voltage Measurement... 13:50:54 Voltage Offset Correction: v_off_ini = 525.914 uV, v_off_fin = 533.686 uV 13:50:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.005 uVs 13:50:54 Integrated Voltage Measurement... 13:51:03 Voltage Offset Correction: v_off_ini = 525.597 uV, v_off_fin = 528.988 uV 13:51:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.307 uVs 13:51:03 Integrated Voltage Measurement... 13:51:12 Voltage Offset Correction: v_off_ini = 542.425 uV, v_off_fin = 538.517 uV 13:51:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.148 uVs 13:51:12 Integrated Voltage Measurement... 13:51:21 Voltage Offset Correction: v_off_ini = 539.463 uV, v_off_fin = 534.301 uV 13:51:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.800 uVs 13:51:23 I2Y Average and RMS of Measurements VT = -270.276 +- 2.995 uVs I2Y = -24.865 +- 0.275 uTm^2 13:51:27 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:51:32 Integrated Voltage Measurement... 13:51:41 Voltage Offset Correction: v_off_ini = 501.423 uV, v_off_fin = 518.111 uV 13:51:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.195 uVs 13:51:41 Integrated Voltage Measurement... 13:51:50 Voltage Offset Correction: v_off_ini = 493.922 uV, v_off_fin = 513.463 uV 13:51:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.267 uVs 13:51:50 Integrated Voltage Measurement... 13:51:59 Voltage Offset Correction: v_off_ini = 532.115 uV, v_off_fin = 522.630 uV 13:51:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.358 uVs 13:51:59 Integrated Voltage Measurement... 13:52:08 Voltage Offset Correction: v_off_ini = 540.692 uV, v_off_fin = 535.889 uV 13:52:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.409 uVs 13:52:08 Integrated Voltage Measurement... 13:52:17 Voltage Offset Correction: v_off_ini = 521.722 uV, v_off_fin = 538.848 uV 13:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.164 uVs 13:52:17 Integrated Voltage Measurement... 13:52:26 Voltage Offset Correction: v_off_ini = 544.994 uV, v_off_fin = 556.100 uV 13:52:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.387 uVs 13:52:30 I1X Average and RMS of Measurements VT = -72.297 +- 11.686 uVs I1X = 14.460 +- 2.337 uTm 13:52:32 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:52:37 Integrated Voltage Measurement... 13:52:46 Voltage Offset Correction: v_off_ini = 548.770 uV, v_off_fin = 539.525 uV 13:52:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.676 uVs 13:52:46 Integrated Voltage Measurement... 13:52:55 Voltage Offset Correction: v_off_ini = 561.961 uV, v_off_fin = 572.230 uV 13:52:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.535 uVs 13:52:55 Integrated Voltage Measurement... 13:53:04 Voltage Offset Correction: v_off_ini = 566.022 uV, v_off_fin = 541.026 uV 13:53:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.265 uVs 13:53:04 Integrated Voltage Measurement... 13:53:13 Voltage Offset Correction: v_off_ini = 530.919 uV, v_off_fin = 546.257 uV 13:53:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.009 uVs 13:53:13 Integrated Voltage Measurement... 13:53:22 Voltage Offset Correction: v_off_ini = 533.375 uV, v_off_fin = 539.949 uV 13:53:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.144 uVs 13:53:22 Integrated Voltage Measurement... 13:53:31 Voltage Offset Correction: v_off_ini = 555.286 uV, v_off_fin = 575.533 uV 13:53:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.306 uVs 13:53:35 I1Y Average and RMS of Measurements VT = -186.656 +- 3.896 uVs I1Y = -37.331 +- 0.780 uTm 13:53:37 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:53:40 Integrated Voltage Measurement... 13:53:49 Voltage Offset Correction: v_off_ini = 529.260 uV, v_off_fin = 527.490 uV 13:53:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.012 uVs 13:53:49 Integrated Voltage Measurement... 13:53:58 Voltage Offset Correction: v_off_ini = 543.700 uV, v_off_fin = 549.621 uV 13:53:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.830 uVs 13:53:58 Integrated Voltage Measurement... 13:54:07 Voltage Offset Correction: v_off_ini = 544.701 uV, v_off_fin = 538.363 uV 13:54:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.960 uVs 13:54:07 Integrated Voltage Measurement... 13:54:16 Voltage Offset Correction: v_off_ini = 549.054 uV, v_off_fin = 557.397 uV 13:54:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.770 uVs 13:54:16 Integrated Voltage Measurement... 13:54:25 Voltage Offset Correction: v_off_ini = 528.915 uV, v_off_fin = 542.727 uV 13:54:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.414 uVs 13:54:25 Integrated Voltage Measurement... 13:54:34 Voltage Offset Correction: v_off_ini = 547.802 uV, v_off_fin = 548.519 uV 13:54:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.436 uVs 13:54:37 I2X Average and RMS of Measurements VT = -96.904 +- 8.950 uVs I2X = 8.915 +- 0.823 uTm^2 13:54:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:54:42 Integrated Voltage Measurement... 13:54:51 Voltage Offset Correction: v_off_ini = 553.051 uV, v_off_fin = 528.439 uV 13:54:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.134 uVs 13:54:51 Integrated Voltage Measurement... 13:55:00 Voltage Offset Correction: v_off_ini = 543.144 uV, v_off_fin = 528.667 uV 13:55:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.207 uVs 13:55:00 Integrated Voltage Measurement... 13:55:09 Voltage Offset Correction: v_off_ini = 533.764 uV, v_off_fin = 540.203 uV 13:55:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.144 uVs 13:55:09 Integrated Voltage Measurement... 13:55:18 Voltage Offset Correction: v_off_ini = 531.177 uV, v_off_fin = 526.904 uV 13:55:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.345 uVs 13:55:18 Integrated Voltage Measurement... 13:55:27 Voltage Offset Correction: v_off_ini = 525.326 uV, v_off_fin = 515.727 uV 13:55:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.011 uVs 13:55:27 Integrated Voltage Measurement... 13:55:36 Voltage Offset Correction: v_off_ini = 517.057 uV, v_off_fin = 521.115 uV 13:55:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.142 uVs 13:55:38 I2Y Average and RMS of Measurements VT = -263.164 +- 6.090 uVs I2Y = -24.211 +- 0.560 uTm^2 13:55:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:55:59 Integrated Voltage Measurement... 13:56:08 Voltage Offset Correction: v_off_ini = 529.329 uV, v_off_fin = 525.105 uV 13:56:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.922 uVs 13:56:08 Integrated Voltage Measurement... 13:56:17 Voltage Offset Correction: v_off_ini = 533.095 uV, v_off_fin = 532.043 uV 13:56:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.090 uVs 13:56:17 Integrated Voltage Measurement... 13:56:26 Voltage Offset Correction: v_off_ini = 538.910 uV, v_off_fin = 542.845 uV 13:56:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.939 uVs 13:56:26 Integrated Voltage Measurement... 13:56:35 Voltage Offset Correction: v_off_ini = 530.962 uV, v_off_fin = 527.270 uV 13:56:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.224 uVs 13:56:35 Integrated Voltage Measurement... 13:56:44 Voltage Offset Correction: v_off_ini = 515.423 uV, v_off_fin = 536.117 uV 13:56:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.219 uVs 13:56:44 Integrated Voltage Measurement... 13:56:53 Voltage Offset Correction: v_off_ini = 532.804 uV, v_off_fin = 527.231 uV 13:56:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.833 uVs 13:56:57 I1X Average and RMS of Measurements VT = -97.705 +- 4.581 uVs I1X = 19.541 +- 0.916 uTm 13:56:59 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:57:04 Integrated Voltage Measurement... 13:57:13 Voltage Offset Correction: v_off_ini = 533.410 uV, v_off_fin = 526.581 uV 13:57:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.686 uVs 13:57:13 Integrated Voltage Measurement... 13:57:22 Voltage Offset Correction: v_off_ini = 530.697 uV, v_off_fin = 539.578 uV 13:57:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.284 uVs 13:57:22 Integrated Voltage Measurement... 13:57:31 Voltage Offset Correction: v_off_ini = 541.446 uV, v_off_fin = 529.371 uV 13:57:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.223 uVs 13:57:31 Integrated Voltage Measurement... 13:57:40 Voltage Offset Correction: v_off_ini = 550.735 uV, v_off_fin = 548.559 uV 13:57:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.538 uVs 13:57:40 Integrated Voltage Measurement... 13:57:49 Voltage Offset Correction: v_off_ini = 560.314 uV, v_off_fin = 549.915 uV 13:57:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.256 uVs 13:57:49 Integrated Voltage Measurement... 13:57:58 Voltage Offset Correction: v_off_ini = 552.858 uV, v_off_fin = 577.711 uV 13:57:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.127 uVs 13:58:02 I1Y Average and RMS of Measurements VT = -196.519 +- 1.794 uVs I1Y = -39.304 +- 0.359 uTm 13:58:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:58:10 Integrated Voltage Measurement... 13:58:18 Voltage Offset Correction: v_off_ini = 560.643 uV, v_off_fin = 555.601 uV 13:58:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.692 uVs 13:58:19 Integrated Voltage Measurement... 13:58:27 Voltage Offset Correction: v_off_ini = 584.211 uV, v_off_fin = 595.985 uV 13:58:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.481 uVs 13:58:28 Integrated Voltage Measurement... 13:58:37 Voltage Offset Correction: v_off_ini = 572.092 uV, v_off_fin = 585.461 uV 13:58:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.891 uVs 13:58:37 Integrated Voltage Measurement... 13:58:46 Voltage Offset Correction: v_off_ini = 590.008 uV, v_off_fin = 593.940 uV 13:58:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.316 uVs 13:58:46 Integrated Voltage Measurement... 13:58:55 Voltage Offset Correction: v_off_ini = 596.542 uV, v_off_fin = 568.435 uV 13:58:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.387 uVs 13:58:55 Integrated Voltage Measurement... 13:59:04 Voltage Offset Correction: v_off_ini = 580.877 uV, v_off_fin = 585.574 uV 13:59:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.165 uVs 13:59:06 I2X Average and RMS of Measurements VT = -115.822 +- 2.735 uVs I2X = 10.656 +- 0.252 uTm^2 13:59:11 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:59:14 Integrated Voltage Measurement... 13:59:23 Voltage Offset Correction: v_off_ini = 602.455 uV, v_off_fin = 589.514 uV 13:59:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.737 uVs 13:59:23 Integrated Voltage Measurement... 13:59:32 Voltage Offset Correction: v_off_ini = 593.198 uV, v_off_fin = 601.967 uV 13:59:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.987 uVs 13:59:32 Integrated Voltage Measurement... 13:59:41 Voltage Offset Correction: v_off_ini = 623.087 uV, v_off_fin = 611.144 uV 13:59:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.259 uVs 13:59:41 Integrated Voltage Measurement... 13:59:50 Voltage Offset Correction: v_off_ini = 632.257 uV, v_off_fin = 625.587 uV 13:59:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.013 uVs 13:59:50 Integrated Voltage Measurement... 13:59:59 Voltage Offset Correction: v_off_ini = 630.094 uV, v_off_fin = 638.408 uV 13:59:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.491 uVs 13:59:59 Integrated Voltage Measurement... 14:00:08 Voltage Offset Correction: v_off_ini = 619.393 uV, v_off_fin = 606.790 uV 14:00:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.458 uVs 14:00:10 I2Y Average and RMS of Measurements VT = -267.991 +- 0.869 uVs I2Y = -24.655 +- 0.080 uTm^2 14:00:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:00:19 Integrated Voltage Measurement... 14:00:28 Voltage Offset Correction: v_off_ini = 658.873 uV, v_off_fin = 651.284 uV 14:00:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.792 uVs 14:00:28 Integrated Voltage Measurement... 14:00:37 Voltage Offset Correction: v_off_ini = 637.331 uV, v_off_fin = 643.748 uV 14:00:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.613 uVs 14:00:37 Integrated Voltage Measurement... 14:00:46 Voltage Offset Correction: v_off_ini = 651.569 uV, v_off_fin = 648.816 uV 14:00:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.190 uVs 14:00:46 Integrated Voltage Measurement... 14:00:55 Voltage Offset Correction: v_off_ini = 653.475 uV, v_off_fin = 648.591 uV 14:00:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.652 uVs 14:00:55 Integrated Voltage Measurement... 14:01:04 Voltage Offset Correction: v_off_ini = 653.938 uV, v_off_fin = 638.418 uV 14:01:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.627 uVs 14:01:04 Integrated Voltage Measurement... 14:01:13 Voltage Offset Correction: v_off_ini = 647.106 uV, v_off_fin = 649.633 uV 14:01:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.040 uVs 14:01:17 I1X Average and RMS of Measurements VT = -88.152 +- 6.046 uVs I1X = 17.630 +- 1.209 uTm 14:01:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:01:24 Integrated Voltage Measurement... 14:01:33 Voltage Offset Correction: v_off_ini = 649.135 uV, v_off_fin = 624.102 uV 14:01:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.259 uVs 14:01:33 Integrated Voltage Measurement... 14:01:42 Voltage Offset Correction: v_off_ini = 627.807 uV, v_off_fin = 655.650 uV 14:01:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.348 uVs 14:01:42 Integrated Voltage Measurement... 14:01:51 Voltage Offset Correction: v_off_ini = 641.955 uV, v_off_fin = 636.104 uV 14:01:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.794 uVs 14:01:51 Integrated Voltage Measurement... 14:02:00 Voltage Offset Correction: v_off_ini = 652.161 uV, v_off_fin = 640.727 uV 14:02:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.189 uVs 14:02:00 Integrated Voltage Measurement... 14:02:09 Voltage Offset Correction: v_off_ini = 644.142 uV, v_off_fin = 624.346 uV 14:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.896 uVs 14:02:09 Integrated Voltage Measurement... 14:02:18 Voltage Offset Correction: v_off_ini = 661.074 uV, v_off_fin = 654.250 uV 14:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.079 uVs 14:02:23 I1Y Average and RMS of Measurements VT = -192.594 +- 0.542 uVs I1Y = -38.519 +- 0.108 uTm 14:02:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:02:30 Integrated Voltage Measurement... 14:02:39 Voltage Offset Correction: v_off_ini = 668.049 uV, v_off_fin = 668.977 uV 14:02:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.317 uVs 14:02:39 Integrated Voltage Measurement... 14:02:48 Voltage Offset Correction: v_off_ini = 652.822 uV, v_off_fin = 663.261 uV 14:02:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.359 uVs 14:02:48 Integrated Voltage Measurement... 14:02:57 Voltage Offset Correction: v_off_ini = 674.116 uV, v_off_fin = 654.602 uV 14:02:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.716 uVs 14:02:57 Integrated Voltage Measurement... 14:03:06 Voltage Offset Correction: v_off_ini = 666.562 uV, v_off_fin = 686.369 uV 14:03:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.064 uVs 14:03:06 Integrated Voltage Measurement... 14:03:15 Voltage Offset Correction: v_off_ini = 668.383 uV, v_off_fin = 663.695 uV 14:03:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.145 uVs 14:03:15 Integrated Voltage Measurement... 14:03:24 Voltage Offset Correction: v_off_ini = 659.603 uV, v_off_fin = 654.230 uV 14:03:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 120.737 uVs 14:03:27 I2X Average and RMS of Measurements VT = -104.723 +- 6.019 uVs I2X = 9.635 +- 0.554 uTm^2 14:03:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:03:34 Integrated Voltage Measurement... 14:03:43 Voltage Offset Correction: v_off_ini = 659.652 uV, v_off_fin = 656.122 uV 14:03:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.036 uVs 14:03:43 Integrated Voltage Measurement... 14:03:52 Voltage Offset Correction: v_off_ini = 634.257 uV, v_off_fin = 647.218 uV 14:03:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.681 uVs 14:03:53 Integrated Voltage Measurement... 14:04:02 Voltage Offset Correction: v_off_ini = 652.219 uV, v_off_fin = 646.628 uV 14:04:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.465 uVs 14:04:02 Integrated Voltage Measurement... 14:04:11 Voltage Offset Correction: v_off_ini = 633.949 uV, v_off_fin = 653.410 uV 14:04:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.559 uVs 14:04:11 Integrated Voltage Measurement... 14:04:20 Voltage Offset Correction: v_off_ini = 653.835 uV, v_off_fin = 645.853 uV 14:04:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.414 uVs 14:04:20 Integrated Voltage Measurement... 14:04:29 Voltage Offset Correction: v_off_ini = 648.077 uV, v_off_fin = 641.396 uV 14:04:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.485 uVs 14:04:31 I2Y Average and RMS of Measurements VT = -279.773 +- 6.152 uVs I2Y = -25.739 +- 0.566 uTm^2 14:04:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:40 Integrated Voltage Measurement... 14:04:49 Voltage Offset Correction: v_off_ini = 667.399 uV, v_off_fin = 662.008 uV 14:04:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.963 uVs 14:04:49 Integrated Voltage Measurement... 14:04:58 Voltage Offset Correction: v_off_ini = 642.512 uV, v_off_fin = 669.850 uV 14:04:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.655 uVs 14:04:58 Integrated Voltage Measurement... 14:05:07 Voltage Offset Correction: v_off_ini = 667.826 uV, v_off_fin = 656.784 uV 14:05:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.122 uVs 14:05:07 Integrated Voltage Measurement... 14:05:16 Voltage Offset Correction: v_off_ini = 642.651 uV, v_off_fin = 666.237 uV 14:05:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.317 uVs 14:05:16 Integrated Voltage Measurement... 14:05:25 Voltage Offset Correction: v_off_ini = 656.719 uV, v_off_fin = 661.065 uV 14:05:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.059 uVs 14:05:25 Integrated Voltage Measurement... 14:05:34 Voltage Offset Correction: v_off_ini = 662.470 uV, v_off_fin = 667.184 uV 14:05:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.885 uVs 14:05:38 I1X Average and RMS of Measurements VT = -92.167 +- 12.224 uVs I1X = 18.433 +- 2.445 uTm 14:05:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:45 Integrated Voltage Measurement... 14:05:54 Voltage Offset Correction: v_off_ini = 654.606 uV, v_off_fin = 651.952 uV 14:05:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.800 uVs 14:05:54 Integrated Voltage Measurement... 14:06:03 Voltage Offset Correction: v_off_ini = 647.273 uV, v_off_fin = 675.328 uV 14:06:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.729 uVs 14:06:03 Integrated Voltage Measurement... 14:06:12 Voltage Offset Correction: v_off_ini = 677.567 uV, v_off_fin = 657.716 uV 14:06:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.572 uVs 14:06:12 Integrated Voltage Measurement... 14:06:21 Voltage Offset Correction: v_off_ini = 666.313 uV, v_off_fin = 680.706 uV 14:06:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.222 uVs 14:06:21 Integrated Voltage Measurement... 14:06:30 Voltage Offset Correction: v_off_ini = 638.173 uV, v_off_fin = 640.495 uV 14:06:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.622 uVs 14:06:30 Integrated Voltage Measurement... 14:06:39 Voltage Offset Correction: v_off_ini = 652.812 uV, v_off_fin = 658.924 uV 14:06:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.587 uVs 14:06:43 I1Y Average and RMS of Measurements VT = -195.589 +- 1.767 uVs I1Y = -39.118 +- 0.353 uTm 14:06:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:51 Integrated Voltage Measurement... 14:07:00 Voltage Offset Correction: v_off_ini = 634.090 uV, v_off_fin = 630.415 uV 14:07:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.903 uVs 14:07:00 Integrated Voltage Measurement... 14:07:09 Voltage Offset Correction: v_off_ini = 665.822 uV, v_off_fin = 665.977 uV 14:07:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.546 uVs 14:07:09 Integrated Voltage Measurement... 14:07:18 Voltage Offset Correction: v_off_ini = 656.914 uV, v_off_fin = 638.837 uV 14:07:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.844 uVs 14:07:18 Integrated Voltage Measurement... 14:07:27 Voltage Offset Correction: v_off_ini = 643.267 uV, v_off_fin = 645.110 uV 14:07:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.250 uVs 14:07:27 Integrated Voltage Measurement... 14:07:36 Voltage Offset Correction: v_off_ini = 648.947 uV, v_off_fin = 640.810 uV 14:07:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.709 uVs 14:07:36 Integrated Voltage Measurement... 14:07:45 Voltage Offset Correction: v_off_ini = 648.573 uV, v_off_fin = 635.439 uV 14:07:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.583 uVs 14:07:47 I2X Average and RMS of Measurements VT = -96.639 +- 9.051 uVs I2X = 8.891 +- 0.833 uTm^2 14:07:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:07:55 Integrated Voltage Measurement... 14:08:04 Voltage Offset Correction: v_off_ini = 652.527 uV, v_off_fin = 659.340 uV 14:08:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.585 uVs 14:08:04 Integrated Voltage Measurement... 14:08:13 Voltage Offset Correction: v_off_ini = 643.525 uV, v_off_fin = 635.026 uV 14:08:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.578 uVs 14:08:13 Integrated Voltage Measurement... 14:08:22 Voltage Offset Correction: v_off_ini = 649.656 uV, v_off_fin = 658.932 uV 14:08:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.782 uVs 14:08:22 Integrated Voltage Measurement... 14:08:31 Voltage Offset Correction: v_off_ini = 647.084 uV, v_off_fin = 648.707 uV 14:08:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.315 uVs 14:08:31 Integrated Voltage Measurement... 14:08:40 Voltage Offset Correction: v_off_ini = 652.554 uV, v_off_fin = 660.756 uV 14:08:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.519 uVs 14:08:40 Integrated Voltage Measurement... 14:08:49 Voltage Offset Correction: v_off_ini = 656.205 uV, v_off_fin = 639.202 uV 14:08:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.167 uVs 14:08:51 I2Y Average and RMS of Measurements VT = -252.491 +- 3.612 uVs I2Y = -23.229 +- 0.332 uTm^2 14:08:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:09:00 Integrated Voltage Measurement... 14:09:09 Voltage Offset Correction: v_off_ini = 631.040 uV, v_off_fin = 645.178 uV 14:09:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.819 uVs 14:09:09 Integrated Voltage Measurement... 14:09:18 Voltage Offset Correction: v_off_ini = 668.764 uV, v_off_fin = 650.822 uV 14:09:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.927 uVs 14:09:18 Integrated Voltage Measurement... 14:09:27 Voltage Offset Correction: v_off_ini = 670.281 uV, v_off_fin = 677.756 uV 14:09:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.742 uVs 14:09:27 Integrated Voltage Measurement... 14:09:36 Voltage Offset Correction: v_off_ini = 675.377 uV, v_off_fin = 654.414 uV 14:09:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.504 uVs 14:09:36 Integrated Voltage Measurement... 14:09:45 Voltage Offset Correction: v_off_ini = 667.227 uV, v_off_fin = 663.125 uV 14:09:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.353 uVs 14:09:45 Integrated Voltage Measurement... 14:09:54 Voltage Offset Correction: v_off_ini = 649.271 uV, v_off_fin = 662.226 uV 14:09:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.260 uVs 14:09:58 I1X Average and RMS of Measurements VT = -85.601 +- 8.110 uVs I1X = 17.121 +- 1.622 uTm 14:10:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:10:05 Integrated Voltage Measurement... 14:10:14 Voltage Offset Correction: v_off_ini = 650.352 uV, v_off_fin = 656.921 uV 14:10:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.655 uVs 14:10:14 Integrated Voltage Measurement... 14:10:23 Voltage Offset Correction: v_off_ini = 662.762 uV, v_off_fin = 662.270 uV 14:10:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.211 uVs 14:10:23 Integrated Voltage Measurement... 14:10:32 Voltage Offset Correction: v_off_ini = 673.414 uV, v_off_fin = 644.835 uV 14:10:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.394 uVs 14:10:32 Integrated Voltage Measurement... 14:10:41 Voltage Offset Correction: v_off_ini = 638.974 uV, v_off_fin = 644.237 uV 14:10:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.431 uVs 14:10:41 Integrated Voltage Measurement... 14:10:50 Voltage Offset Correction: v_off_ini = 653.531 uV, v_off_fin = 649.972 uV 14:10:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.329 uVs 14:10:50 Integrated Voltage Measurement... 14:10:59 Voltage Offset Correction: v_off_ini = 664.876 uV, v_off_fin = 674.092 uV 14:10:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.581 uVs 14:11:03 I1Y Average and RMS of Measurements VT = -192.767 +- 3.022 uVs I1Y = -38.553 +- 0.604 uTm 14:11:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:11:11 Integrated Voltage Measurement... 14:11:20 Voltage Offset Correction: v_off_ini = 679.217 uV, v_off_fin = 653.571 uV 14:11:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.082 uVs 14:11:20 Integrated Voltage Measurement... 14:11:29 Voltage Offset Correction: v_off_ini = 669.775 uV, v_off_fin = 675.895 uV 14:11:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.785 uVs 14:11:29 Integrated Voltage Measurement... 14:11:38 Voltage Offset Correction: v_off_ini = 673.117 uV, v_off_fin = 657.730 uV 14:11:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.653 uVs 14:11:38 Integrated Voltage Measurement... 14:11:47 Voltage Offset Correction: v_off_ini = 669.353 uV, v_off_fin = 676.532 uV 14:11:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.247 uVs 14:11:47 Integrated Voltage Measurement... 14:11:56 Voltage Offset Correction: v_off_ini = 677.876 uV, v_off_fin = 680.331 uV 14:11:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.215 uVs 14:11:56 Integrated Voltage Measurement... 14:12:05 Voltage Offset Correction: v_off_ini = 698.823 uV, v_off_fin = 685.690 uV 14:12:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.684 uVs 14:12:08 I2X Average and RMS of Measurements VT = -91.611 +- 2.649 uVs I2X = 8.428 +- 0.244 uTm^2 14:12:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:12:15 Integrated Voltage Measurement... 14:12:24 Voltage Offset Correction: v_off_ini = 729.586 uV, v_off_fin = 712.975 uV 14:12:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.236 uVs 14:12:24 Integrated Voltage Measurement... 14:12:33 Voltage Offset Correction: v_off_ini = 725.119 uV, v_off_fin = 725.733 uV 14:12:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.904 uVs 14:12:34 Integrated Voltage Measurement... 14:12:43 Voltage Offset Correction: v_off_ini = 720.390 uV, v_off_fin = 726.749 uV 14:12:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.971 uVs 14:12:43 Integrated Voltage Measurement... 14:12:52 Voltage Offset Correction: v_off_ini = 738.858 uV, v_off_fin = 743.019 uV 14:12:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 240.236 uVs 14:12:52 Integrated Voltage Measurement... 14:13:01 Voltage Offset Correction: v_off_ini = 719.832 uV, v_off_fin = 715.082 uV 14:13:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.023 uVs 14:13:01 Integrated Voltage Measurement... 14:13:10 Voltage Offset Correction: v_off_ini = 710.232 uV, v_off_fin = 710.409 uV 14:13:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.159 uVs 14:13:12 I2Y Average and RMS of Measurements VT = -252.088 +- 2.862 uVs I2Y = -23.192 +- 0.263 uTm^2 14:13:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:13:21 Integrated Voltage Measurement... 14:13:30 Voltage Offset Correction: v_off_ini = 728.865 uV, v_off_fin = 767.506 uV 14:13:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.780 uVs 14:13:30 Integrated Voltage Measurement... 14:13:39 Voltage Offset Correction: v_off_ini = 740.178 uV, v_off_fin = 739.935 uV 14:13:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.082 uVs 14:13:39 Integrated Voltage Measurement... 14:13:48 Voltage Offset Correction: v_off_ini = 740.553 uV, v_off_fin = 748.121 uV 14:13:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.814 uVs 14:13:48 Integrated Voltage Measurement... 14:13:57 Voltage Offset Correction: v_off_ini = 733.947 uV, v_off_fin = 746.057 uV 14:13:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.071 uVs 14:13:57 Integrated Voltage Measurement... 14:14:06 Voltage Offset Correction: v_off_ini = 745.632 uV, v_off_fin = 740.586 uV 14:14:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.100 uVs 14:14:06 Integrated Voltage Measurement... 14:14:15 Voltage Offset Correction: v_off_ini = 750.787 uV, v_off_fin = 748.519 uV 14:14:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.674 uVs 14:14:19 I1X Average and RMS of Measurements VT = -72.587 +- 2.243 uVs I1X = 14.518 +- 0.448 uTm 14:14:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:14:26 Integrated Voltage Measurement... 14:14:35 Voltage Offset Correction: v_off_ini = 762.489 uV, v_off_fin = 739.492 uV 14:14:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.694 uVs 14:14:35 Integrated Voltage Measurement... 14:14:44 Voltage Offset Correction: v_off_ini = 741.872 uV, v_off_fin = 753.609 uV 14:14:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.865 uVs 14:14:44 Integrated Voltage Measurement... 14:14:53 Voltage Offset Correction: v_off_ini = 737.834 uV, v_off_fin = 727.355 uV 14:14:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.422 uVs 14:14:53 Integrated Voltage Measurement... 14:15:02 Voltage Offset Correction: v_off_ini = 744.059 uV, v_off_fin = 756.648 uV 14:15:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.251 uVs 14:15:02 Integrated Voltage Measurement... 14:15:11 Voltage Offset Correction: v_off_ini = 754.695 uV, v_off_fin = 731.320 uV 14:15:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.468 uVs 14:15:11 Integrated Voltage Measurement... 14:15:20 Voltage Offset Correction: v_off_ini = 730.532 uV, v_off_fin = 737.999 uV 14:15:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.338 uVs 14:15:25 I1Y Average and RMS of Measurements VT = -174.840 +- 5.361 uVs I1Y = -34.968 +- 1.072 uTm 14:15:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:15:32 Integrated Voltage Measurement... 14:15:41 Voltage Offset Correction: v_off_ini = 723.773 uV, v_off_fin = 732.530 uV 14:15:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.120 uVs 14:15:41 Integrated Voltage Measurement... 14:15:50 Voltage Offset Correction: v_off_ini = 742.785 uV, v_off_fin = 759.269 uV 14:15:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.090 uVs 14:15:50 Integrated Voltage Measurement... 14:15:59 Voltage Offset Correction: v_off_ini = 737.532 uV, v_off_fin = 738.939 uV 14:15:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.965 uVs 14:15:59 Integrated Voltage Measurement... 14:16:08 Voltage Offset Correction: v_off_ini = 739.552 uV, v_off_fin = 741.711 uV 14:16:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.591 uVs 14:16:08 Integrated Voltage Measurement... 14:16:17 Voltage Offset Correction: v_off_ini = 738.033 uV, v_off_fin = 763.443 uV 14:16:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.129 uVs 14:16:17 Integrated Voltage Measurement... 14:16:26 Voltage Offset Correction: v_off_ini = 772.421 uV, v_off_fin = 775.256 uV 14:16:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.353 uVs 14:16:29 I2X Average and RMS of Measurements VT = -86.708 +- 11.581 uVs I2X = 7.977 +- 1.065 uTm^2 14:16:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:16:37 Integrated Voltage Measurement... 14:16:46 Voltage Offset Correction: v_off_ini = 763.638 uV, v_off_fin = 749.754 uV 14:16:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.620 uVs 14:16:46 Integrated Voltage Measurement... 14:16:55 Voltage Offset Correction: v_off_ini = 781.098 uV, v_off_fin = 770.304 uV 14:16:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.852 uVs 14:16:55 Integrated Voltage Measurement... 14:17:04 Voltage Offset Correction: v_off_ini = 773.115 uV, v_off_fin = 767.154 uV 14:17:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.375 uVs 14:17:04 Integrated Voltage Measurement... 14:17:13 Voltage Offset Correction: v_off_ini = 770.275 uV, v_off_fin = 782.529 uV 14:17:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.817 uVs 14:17:13 Integrated Voltage Measurement... 14:17:22 Voltage Offset Correction: v_off_ini = 760.416 uV, v_off_fin = 775.960 uV 14:17:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.771 uVs 14:17:22 Integrated Voltage Measurement... 14:17:31 Voltage Offset Correction: v_off_ini = 792.971 uV, v_off_fin = 771.678 uV 14:17:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.890 uVs 14:17:33 I2Y Average and RMS of Measurements VT = -235.221 +- 4.395 uVs I2Y = -21.640 +- 0.404 uTm^2 14:17:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:17:45 Integrated Voltage Measurement... 14:17:54 Voltage Offset Correction: v_off_ini = 788.367 uV, v_off_fin = 786.703 uV 14:17:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 59.336 uVs 14:17:54 Integrated Voltage Measurement... 14:18:03 Voltage Offset Correction: v_off_ini = 793.216 uV, v_off_fin = 796.754 uV 14:18:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.863 uVs 14:18:03 Integrated Voltage Measurement... 14:18:12 Voltage Offset Correction: v_off_ini = 790.487 uV, v_off_fin = 804.126 uV 14:18:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.084 uVs 14:18:12 Integrated Voltage Measurement... 14:18:21 Voltage Offset Correction: v_off_ini = 780.100 uV, v_off_fin = 787.082 uV 14:18:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.693 uVs 14:18:21 Integrated Voltage Measurement... 14:18:30 Voltage Offset Correction: v_off_ini = 792.474 uV, v_off_fin = 795.035 uV 14:18:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.691 uVs 14:18:30 Integrated Voltage Measurement... 14:18:39 Voltage Offset Correction: v_off_ini = 789.770 uV, v_off_fin = 794.047 uV 14:18:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.810 uVs 14:18:44 I1X Average and RMS of Measurements VT = -57.801 +- 41.699 uVs I1X = 11.560 +- 8.340 uTm 14:18:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:18:50 Integrated Voltage Measurement... 14:18:59 Voltage Offset Correction: v_off_ini = 810.638 uV, v_off_fin = 805.352 uV 14:18:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.532 uVs 14:18:59 Integrated Voltage Measurement... 14:19:08 Voltage Offset Correction: v_off_ini = 806.255 uV, v_off_fin = 807.463 uV 14:19:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.697 uVs 14:19:08 Integrated Voltage Measurement... 14:19:17 Voltage Offset Correction: v_off_ini = 799.226 uV, v_off_fin = 791.824 uV 14:19:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.734 uVs 14:19:17 Integrated Voltage Measurement... 14:19:26 Voltage Offset Correction: v_off_ini = 821.851 uV, v_off_fin = 831.879 uV 14:19:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.480 uVs 14:19:26 Integrated Voltage Measurement... 14:19:35 Voltage Offset Correction: v_off_ini = 827.374 uV, v_off_fin = 835.908 uV 14:19:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.430 uVs 14:19:35 Integrated Voltage Measurement... 14:19:44 Voltage Offset Correction: v_off_ini = 827.562 uV, v_off_fin = 840.412 uV 14:19:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.938 uVs 14:19:49 I1Y Average and RMS of Measurements VT = -203.802 +- 8.360 uVs I1Y = -40.760 +- 1.672 uTm 14:19:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:19:54 Integrated Voltage Measurement... 14:20:03 Voltage Offset Correction: v_off_ini = 834.934 uV, v_off_fin = 824.849 uV 14:20:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.229 uVs 14:20:03 Integrated Voltage Measurement... 14:20:12 Voltage Offset Correction: v_off_ini = 825.625 uV, v_off_fin = 838.583 uV 14:20:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.917 uVs 14:20:12 Integrated Voltage Measurement... 14:20:21 Voltage Offset Correction: v_off_ini = 804.729 uV, v_off_fin = 798.795 uV 14:20:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.370 uVs 14:20:21 Integrated Voltage Measurement... 14:20:30 Voltage Offset Correction: v_off_ini = 789.817 uV, v_off_fin = 802.134 uV 14:20:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.360 uVs 14:20:30 Integrated Voltage Measurement... 14:20:39 Voltage Offset Correction: v_off_ini = 822.110 uV, v_off_fin = 809.217 uV 14:20:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.331 uVs 14:20:39 Integrated Voltage Measurement... 14:20:48 Voltage Offset Correction: v_off_ini = 825.260 uV, v_off_fin = 828.021 uV 14:20:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.052 uVs 14:20:50 I2X Average and RMS of Measurements VT = -104.043 +- 13.210 uVs I2X = 9.572 +- 1.215 uTm^2 14:20:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:20:56 Integrated Voltage Measurement... 14:21:05 Voltage Offset Correction: v_off_ini = 830.145 uV, v_off_fin = 815.507 uV 14:21:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.036 uVs 14:21:05 Integrated Voltage Measurement... 14:21:14 Voltage Offset Correction: v_off_ini = 819.246 uV, v_off_fin = 821.387 uV 14:21:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.207 uVs 14:21:14 Integrated Voltage Measurement... 14:21:23 Voltage Offset Correction: v_off_ini = 823.759 uV, v_off_fin = 826.097 uV 14:21:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.401 uVs 14:21:23 Integrated Voltage Measurement... 14:21:32 Voltage Offset Correction: v_off_ini = 831.056 uV, v_off_fin = 832.395 uV 14:21:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.844 uVs 14:21:32 Integrated Voltage Measurement... 14:21:41 Voltage Offset Correction: v_off_ini = 814.448 uV, v_off_fin = 810.527 uV 14:21:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.410 uVs 14:21:41 Integrated Voltage Measurement... 14:21:50 Voltage Offset Correction: v_off_ini = 830.186 uV, v_off_fin = 806.135 uV 14:21:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.671 uVs 14:21:52 I2Y Average and RMS of Measurements VT = -258.095 +- 10.470 uVs I2Y = -23.745 +- 0.963 uTm^2 14:21:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:22:01 Integrated Voltage Measurement... 14:22:10 Voltage Offset Correction: v_off_ini = 811.982 uV, v_off_fin = 801.631 uV 14:22:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.542 uVs 14:22:10 Integrated Voltage Measurement... 14:22:19 Voltage Offset Correction: v_off_ini = 816.823 uV, v_off_fin = 824.009 uV 14:22:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 74.950 uVs 14:22:19 Integrated Voltage Measurement... 14:22:28 Voltage Offset Correction: v_off_ini = 825.932 uV, v_off_fin = 820.941 uV 14:22:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.662 uVs 14:22:28 Integrated Voltage Measurement... 14:22:37 Voltage Offset Correction: v_off_ini = 827.777 uV, v_off_fin = 825.363 uV 14:22:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.523 uVs 14:22:37 Integrated Voltage Measurement... 14:22:46 Voltage Offset Correction: v_off_ini = 810.751 uV, v_off_fin = 821.997 uV 14:22:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.993 uVs 14:22:46 Integrated Voltage Measurement... 14:22:55 Voltage Offset Correction: v_off_ini = 823.954 uV, v_off_fin = 804.729 uV 14:22:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.081 uVs 14:22:59 I1X Average and RMS of Measurements VT = -72.625 +- 1.478 uVs I1X = 14.525 +- 0.296 uTm 14:23:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:23:06 Integrated Voltage Measurement... 14:23:15 Voltage Offset Correction: v_off_ini = 790.557 uV, v_off_fin = 778.717 uV 14:23:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.967 uVs 14:23:15 Integrated Voltage Measurement... 14:23:24 Voltage Offset Correction: v_off_ini = 792.740 uV, v_off_fin = 799.868 uV 14:23:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.883 uVs 14:23:24 Integrated Voltage Measurement... 14:23:33 Voltage Offset Correction: v_off_ini = 801.194 uV, v_off_fin = 814.042 uV 14:23:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.082 uVs 14:23:33 Integrated Voltage Measurement... 14:23:42 Voltage Offset Correction: v_off_ini = 804.314 uV, v_off_fin = 805.756 uV 14:23:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.797 uVs 14:23:42 Integrated Voltage Measurement... 14:23:51 Voltage Offset Correction: v_off_ini = 782.215 uV, v_off_fin = 785.900 uV 14:23:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.335 uVs 14:23:51 Integrated Voltage Measurement... 14:24:00 Voltage Offset Correction: v_off_ini = 780.460 uV, v_off_fin = 785.992 uV 14:24:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.829 uVs 14:24:04 I1Y Average and RMS of Measurements VT = -196.482 +- 7.623 uVs I1Y = -39.296 +- 1.525 uTm 14:24:06 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:24:09 Integrated Voltage Measurement... 14:24:18 Voltage Offset Correction: v_off_ini = 804.236 uV, v_off_fin = 803.520 uV 14:24:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.887 uVs 14:24:18 Integrated Voltage Measurement... 14:24:27 Voltage Offset Correction: v_off_ini = 815.718 uV, v_off_fin = 811.237 uV 14:24:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.236 uVs 14:24:27 Integrated Voltage Measurement... 14:24:36 Voltage Offset Correction: v_off_ini = 809.341 uV, v_off_fin = 819.582 uV 14:24:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.299 uVs 14:24:36 Integrated Voltage Measurement... 14:24:45 Voltage Offset Correction: v_off_ini = 820.250 uV, v_off_fin = 815.865 uV 14:24:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.224 uVs 14:24:45 Integrated Voltage Measurement... 14:24:54 Voltage Offset Correction: v_off_ini = 803.127 uV, v_off_fin = 809.565 uV 14:24:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.998 uVs 14:24:54 Integrated Voltage Measurement... 14:25:03 Voltage Offset Correction: v_off_ini = 820.973 uV, v_off_fin = 826.944 uV 14:25:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.489 uVs 14:25:06 I2X Average and RMS of Measurements VT = -98.689 +- 3.080 uVs I2X = 9.079 +- 0.283 uTm^2 14:25:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:25:11 Integrated Voltage Measurement... 14:25:20 Voltage Offset Correction: v_off_ini = 814.496 uV, v_off_fin = 795.459 uV 14:25:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.823 uVs 14:25:20 Integrated Voltage Measurement... 14:25:29 Voltage Offset Correction: v_off_ini = 809.419 uV, v_off_fin = 815.959 uV 14:25:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.787 uVs 14:25:29 Integrated Voltage Measurement... 14:25:38 Voltage Offset Correction: v_off_ini = 830.444 uV, v_off_fin = 825.765 uV 14:25:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.506 uVs 14:25:38 Integrated Voltage Measurement... 14:25:47 Voltage Offset Correction: v_off_ini = 822.261 uV, v_off_fin = 824.697 uV 14:25:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.420 uVs 14:25:47 Integrated Voltage Measurement... 14:25:56 Voltage Offset Correction: v_off_ini = 812.988 uV, v_off_fin = 806.741 uV 14:25:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.025 uVs 14:25:56 Integrated Voltage Measurement... 14:26:05 Voltage Offset Correction: v_off_ini = 803.117 uV, v_off_fin = 828.476 uV 14:26:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.530 uVs 14:26:07 I2Y Average and RMS of Measurements VT = -260.515 +- 12.077 uVs I2Y = -23.967 +- 1.111 uTm^2 14:26:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:16 Integrated Voltage Measurement... 14:26:25 Voltage Offset Correction: v_off_ini = 834.228 uV, v_off_fin = 829.980 uV 14:26:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.192 uVs 14:26:25 Integrated Voltage Measurement... 14:26:34 Voltage Offset Correction: v_off_ini = 835.372 uV, v_off_fin = 833.558 uV 14:26:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.797 uVs 14:26:34 Integrated Voltage Measurement... 14:26:43 Voltage Offset Correction: v_off_ini = 831.679 uV, v_off_fin = 844.100 uV 14:26:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.970 uVs 14:26:43 Integrated Voltage Measurement... 14:26:52 Voltage Offset Correction: v_off_ini = 831.512 uV, v_off_fin = 827.613 uV 14:26:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.172 uVs 14:26:52 Integrated Voltage Measurement... 14:27:01 Voltage Offset Correction: v_off_ini = 826.905 uV, v_off_fin = 850.880 uV 14:27:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.560 uVs 14:27:01 Integrated Voltage Measurement... 14:27:10 Voltage Offset Correction: v_off_ini = 839.887 uV, v_off_fin = 843.948 uV 14:27:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.430 uVs 14:27:14 I1X Average and RMS of Measurements VT = -86.020 +- 7.624 uVs I1X = 17.204 +- 1.525 uTm 14:27:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:27:21 Integrated Voltage Measurement... 14:27:30 Voltage Offset Correction: v_off_ini = 866.625 uV, v_off_fin = 857.200 uV 14:27:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.722 uVs 14:27:30 Integrated Voltage Measurement... 14:27:39 Voltage Offset Correction: v_off_ini = 857.072 uV, v_off_fin = 858.982 uV 14:27:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.022 uVs 14:27:39 Integrated Voltage Measurement... 14:27:48 Voltage Offset Correction: v_off_ini = 842.248 uV, v_off_fin = 840.637 uV 14:27:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.486 uVs 14:27:48 Integrated Voltage Measurement... 14:27:57 Voltage Offset Correction: v_off_ini = 842.218 uV, v_off_fin = 862.842 uV 14:27:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.766 uVs 14:27:57 Integrated Voltage Measurement... 14:28:06 Voltage Offset Correction: v_off_ini = 840.861 uV, v_off_fin = 830.646 uV 14:28:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.203 uVs 14:28:06 Integrated Voltage Measurement... 14:28:15 Voltage Offset Correction: v_off_ini = 835.501 uV, v_off_fin = 858.426 uV 14:28:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.933 uVs 14:28:19 I1Y Average and RMS of Measurements VT = -190.855 +- 2.344 uVs I1Y = -38.172 +- 0.469 uTm 14:28:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:28:24 Integrated Voltage Measurement... 14:28:33 Voltage Offset Correction: v_off_ini = 836.060 uV, v_off_fin = 833.430 uV 14:28:33 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.667 uVs 14:28:33 Integrated Voltage Measurement... 14:28:42 Voltage Offset Correction: v_off_ini = 846.568 uV, v_off_fin = 841.098 uV 14:28:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.820 uVs 14:28:42 Integrated Voltage Measurement... 14:28:51 Voltage Offset Correction: v_off_ini = 811.965 uV, v_off_fin = 816.145 uV 14:28:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.630 uVs 14:28:51 Integrated Voltage Measurement... 14:29:00 Voltage Offset Correction: v_off_ini = 815.110 uV, v_off_fin = 846.873 uV 14:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.420 uVs 14:29:00 Integrated Voltage Measurement... 14:29:09 Voltage Offset Correction: v_off_ini = 818.353 uV, v_off_fin = 823.829 uV 14:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.307 uVs 14:29:09 Integrated Voltage Measurement... 14:29:18 Voltage Offset Correction: v_off_ini = 813.003 uV, v_off_fin = 838.751 uV 14:29:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.603 uVs 14:29:21 I2X Average and RMS of Measurements VT = -96.741 +- 7.485 uVs I2X = 8.900 +- 0.689 uTm^2 14:29:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:26 Integrated Voltage Measurement... 14:29:35 Voltage Offset Correction: v_off_ini = 822.035 uV, v_off_fin = 826.312 uV 14:29:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.154 uVs 14:29:35 Integrated Voltage Measurement... 14:29:44 Voltage Offset Correction: v_off_ini = 822.231 uV, v_off_fin = 820.786 uV 14:29:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 248.817 uVs 14:29:44 Integrated Voltage Measurement... 14:29:53 Voltage Offset Correction: v_off_ini = 830.281 uV, v_off_fin = 827.351 uV 14:29:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.124 uVs 14:29:53 Integrated Voltage Measurement... 14:30:02 Voltage Offset Correction: v_off_ini = 821.072 uV, v_off_fin = 852.257 uV 14:30:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.683 uVs 14:30:02 Integrated Voltage Measurement... 14:30:11 Voltage Offset Correction: v_off_ini = 852.081 uV, v_off_fin = 849.182 uV 14:30:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.098 uVs 14:30:11 Integrated Voltage Measurement... 14:30:20 Voltage Offset Correction: v_off_ini = 848.328 uV, v_off_fin = 846.914 uV 14:30:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.989 uVs 14:30:23 I2Y Average and RMS of Measurements VT = -254.478 +- 15.319 uVs I2Y = -23.412 +- 1.409 uTm^2 14:30:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:30:31 Integrated Voltage Measurement... 14:30:40 Voltage Offset Correction: v_off_ini = 842.766 uV, v_off_fin = 845.204 uV 14:30:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.776 uVs 14:30:40 Integrated Voltage Measurement... 14:30:49 Voltage Offset Correction: v_off_ini = 860.394 uV, v_off_fin = 859.490 uV 14:30:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.556 uVs 14:30:49 Integrated Voltage Measurement... 14:30:58 Voltage Offset Correction: v_off_ini = 884.011 uV, v_off_fin = 874.351 uV 14:30:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.368 uVs 14:30:58 Integrated Voltage Measurement... 14:31:07 Voltage Offset Correction: v_off_ini = 846.122 uV, v_off_fin = 856.891 uV 14:31:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.074 uVs 14:31:07 Integrated Voltage Measurement... 14:31:16 Voltage Offset Correction: v_off_ini = 851.215 uV, v_off_fin = 860.278 uV 14:31:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.531 uVs 14:31:16 Integrated Voltage Measurement... 14:31:25 Voltage Offset Correction: v_off_ini = 867.598 uV, v_off_fin = 879.181 uV 14:31:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.993 uVs 14:31:29 I1X Average and RMS of Measurements VT = -74.716 +- 18.626 uVs I1X = 14.943 +- 3.725 uTm 14:31:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:31:36 Integrated Voltage Measurement... 14:31:45 Voltage Offset Correction: v_off_ini = 877.896 uV, v_off_fin = 879.343 uV 14:31:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -178.196 uVs 14:31:45 Integrated Voltage Measurement... 14:31:54 Voltage Offset Correction: v_off_ini = 866.116 uV, v_off_fin = 884.030 uV 14:31:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.646 uVs 14:31:54 Integrated Voltage Measurement... 14:32:03 Voltage Offset Correction: v_off_ini = 872.297 uV, v_off_fin = 865.681 uV 14:32:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.813 uVs 14:32:03 Integrated Voltage Measurement... 14:32:12 Voltage Offset Correction: v_off_ini = 878.889 uV, v_off_fin = 855.886 uV 14:32:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 176.864 uVs 14:32:12 Integrated Voltage Measurement... 14:32:21 Voltage Offset Correction: v_off_ini = 871.588 uV, v_off_fin = 862.164 uV 14:32:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.044 uVs 14:32:21 Integrated Voltage Measurement... 14:32:30 Voltage Offset Correction: v_off_ini = 873.393 uV, v_off_fin = 872.581 uV 14:32:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 164.586 uVs 14:32:34 I1Y Average and RMS of Measurements VT = -184.858 +- 3.931 uVs I1Y = -36.970 +- 0.788 uTm 14:32:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:32:39 Integrated Voltage Measurement... 14:32:48 Voltage Offset Correction: v_off_ini = 849.145 uV, v_off_fin = 848.817 uV 14:32:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.197 uVs 14:32:48 Integrated Voltage Measurement... 14:32:57 Voltage Offset Correction: v_off_ini = 854.489 uV, v_off_fin = 835.486 uV 14:32:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.633 uVs 14:32:57 Integrated Voltage Measurement... 14:33:06 Voltage Offset Correction: v_off_ini = 820.499 uV, v_off_fin = 825.462 uV 14:33:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.323 uVs 14:33:06 Integrated Voltage Measurement... 14:33:15 Voltage Offset Correction: v_off_ini = 829.536 uV, v_off_fin = 844.196 uV 14:33:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.216 uVs 14:33:15 Integrated Voltage Measurement... 14:33:24 Voltage Offset Correction: v_off_ini = 804.437 uV, v_off_fin = 815.098 uV 14:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.400 uVs 14:33:25 Integrated Voltage Measurement... 14:33:34 Voltage Offset Correction: v_off_ini = 815.079 uV, v_off_fin = 838.629 uV 14:33:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.696 uVs 14:33:36 I2X Average and RMS of Measurements VT = -92.578 +- 12.569 uVs I2X = 8.517 +- 1.156 uTm^2 14:33:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:33:41 Integrated Voltage Measurement... 14:33:50 Voltage Offset Correction: v_off_ini = 837.832 uV, v_off_fin = 836.427 uV 14:33:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.344 uVs 14:33:50 Integrated Voltage Measurement... 14:33:59 Voltage Offset Correction: v_off_ini = 839.250 uV, v_off_fin = 835.610 uV 14:33:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.985 uVs 14:33:59 Integrated Voltage Measurement... 14:34:08 Voltage Offset Correction: v_off_ini = 812.281 uV, v_off_fin = 819.506 uV 14:34:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.543 uVs 14:34:08 Integrated Voltage Measurement... 14:34:17 Voltage Offset Correction: v_off_ini = 820.986 uV, v_off_fin = 825.928 uV 14:34:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 266.044 uVs 14:34:17 Integrated Voltage Measurement... 14:34:26 Voltage Offset Correction: v_off_ini = 824.905 uV, v_off_fin = 824.854 uV 14:34:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.794 uVs 14:34:26 Integrated Voltage Measurement... 14:34:35 Voltage Offset Correction: v_off_ini = 829.755 uV, v_off_fin = 819.315 uV 14:34:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.242 uVs 14:34:38 I2Y Average and RMS of Measurements VT = -249.325 +- 5.681 uVs I2Y = -22.938 +- 0.522 uTm^2 14:34:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:34:46 Integrated Voltage Measurement... 14:34:55 Voltage Offset Correction: v_off_ini = 844.079 uV, v_off_fin = 845.035 uV 14:34:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -79.620 uVs 14:34:55 Integrated Voltage Measurement... 14:35:04 Voltage Offset Correction: v_off_ini = 842.060 uV, v_off_fin = 835.989 uV 14:35:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.386 uVs 14:35:04 Integrated Voltage Measurement... 14:35:13 Voltage Offset Correction: v_off_ini = 821.782 uV, v_off_fin = 817.755 uV 14:35:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.475 uVs 14:35:13 Integrated Voltage Measurement... 14:35:22 Voltage Offset Correction: v_off_ini = 817.725 uV, v_off_fin = 834.308 uV 14:35:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.671 uVs 14:35:22 Integrated Voltage Measurement... 14:35:31 Voltage Offset Correction: v_off_ini = 840.125 uV, v_off_fin = 835.765 uV 14:35:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.007 uVs 14:35:31 Integrated Voltage Measurement... 14:35:40 Voltage Offset Correction: v_off_ini = 819.796 uV, v_off_fin = 815.433 uV 14:35:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.626 uVs 14:35:44 I1X Average and RMS of Measurements VT = -75.964 +- 3.934 uVs I1X = 15.193 +- 0.786 uTm 14:35:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:35:51 Integrated Voltage Measurement... 14:36:00 Voltage Offset Correction: v_off_ini = 804.390 uV, v_off_fin = 814.832 uV 14:36:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.304 uVs 14:36:00 Integrated Voltage Measurement... 14:36:09 Voltage Offset Correction: v_off_ini = 816.049 uV, v_off_fin = 846.793 uV 14:36:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 176.476 uVs 14:36:09 Integrated Voltage Measurement... 14:36:18 Voltage Offset Correction: v_off_ini = 810.836 uV, v_off_fin = 810.039 uV 14:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.188 uVs 14:36:18 Integrated Voltage Measurement... 14:36:27 Voltage Offset Correction: v_off_ini = 813.249 uV, v_off_fin = 824.706 uV 14:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.572 uVs 14:36:27 Integrated Voltage Measurement... 14:36:36 Voltage Offset Correction: v_off_ini = 823.674 uV, v_off_fin = 816.042 uV 14:36:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.106 uVs 14:36:36 Integrated Voltage Measurement... 14:36:45 Voltage Offset Correction: v_off_ini = 806.728 uV, v_off_fin = 816.396 uV 14:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 153.375 uVs 14:36:49 I1Y Average and RMS of Measurements VT = -173.003 +- 6.124 uVs I1Y = -34.598 +- 1.225 uTm 14:36:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:36:54 Integrated Voltage Measurement... 14:37:03 Voltage Offset Correction: v_off_ini = 797.166 uV, v_off_fin = 803.940 uV 14:37:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.463 uVs 14:37:03 Integrated Voltage Measurement... 14:37:12 Voltage Offset Correction: v_off_ini = 817.143 uV, v_off_fin = 823.877 uV 14:37:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.318 uVs 14:37:12 Integrated Voltage Measurement... 14:37:21 Voltage Offset Correction: v_off_ini = 822.704 uV, v_off_fin = 821.409 uV 14:37:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.539 uVs 14:37:22 Integrated Voltage Measurement... 14:37:31 Voltage Offset Correction: v_off_ini = 824.010 uV, v_off_fin = 835.793 uV 14:37:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.059 uVs 14:37:31 Integrated Voltage Measurement... 14:37:40 Voltage Offset Correction: v_off_ini = 829.486 uV, v_off_fin = 811.920 uV 14:37:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.276 uVs 14:37:40 Integrated Voltage Measurement... 14:37:49 Voltage Offset Correction: v_off_ini = 808.574 uV, v_off_fin = 814.299 uV 14:37:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.530 uVs 14:37:51 I2X Average and RMS of Measurements VT = -95.864 +- 7.862 uVs I2X = 8.820 +- 0.723 uTm^2 14:37:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:37:56 Integrated Voltage Measurement... 14:38:05 Voltage Offset Correction: v_off_ini = 813.140 uV, v_off_fin = 817.221 uV 14:38:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.195 uVs 14:38:05 Integrated Voltage Measurement... 14:38:14 Voltage Offset Correction: v_off_ini = 826.361 uV, v_off_fin = 825.128 uV 14:38:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.232 uVs 14:38:14 Integrated Voltage Measurement... 14:38:23 Voltage Offset Correction: v_off_ini = 835.754 uV, v_off_fin = 829.694 uV 14:38:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.363 uVs 14:38:23 Integrated Voltage Measurement... 14:38:32 Voltage Offset Correction: v_off_ini = 845.585 uV, v_off_fin = 846.016 uV 14:38:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.462 uVs 14:38:32 Integrated Voltage Measurement... 14:38:41 Voltage Offset Correction: v_off_ini = 853.723 uV, v_off_fin = 844.000 uV 14:38:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.186 uVs 14:38:41 Integrated Voltage Measurement... 14:38:50 Voltage Offset Correction: v_off_ini = 852.058 uV, v_off_fin = 863.919 uV 14:38:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.810 uVs 14:38:53 I2Y Average and RMS of Measurements VT = -250.208 +- 4.253 uVs I2Y = -23.019 +- 0.391 uTm^2 14:39:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:39:13 Integrated Voltage Measurement... 14:39:22 Voltage Offset Correction: v_off_ini = 855.279 uV, v_off_fin = 856.889 uV 14:39:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.975 uVs 14:39:22 Integrated Voltage Measurement... 14:39:31 Voltage Offset Correction: v_off_ini = 841.062 uV, v_off_fin = 845.706 uV 14:39:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 92.065 uVs 14:39:31 Integrated Voltage Measurement... 14:39:40 Voltage Offset Correction: v_off_ini = 847.086 uV, v_off_fin = 861.229 uV 14:39:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.529 uVs 14:39:40 Integrated Voltage Measurement... 14:39:49 Voltage Offset Correction: v_off_ini = 854.712 uV, v_off_fin = 862.159 uV 14:39:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.944 uVs 14:39:49 Integrated Voltage Measurement... 14:39:58 Voltage Offset Correction: v_off_ini = 851.841 uV, v_off_fin = 858.351 uV 14:39:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.066 uVs 14:39:58 Integrated Voltage Measurement... 14:40:07 Voltage Offset Correction: v_off_ini = 858.164 uV, v_off_fin = 870.589 uV 14:40:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.808 uVs 14:40:11 I1X Average and RMS of Measurements VT = -90.231 +- 5.239 uVs I1X = 18.047 +- 1.048 uTm 14:40:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:40:18 Integrated Voltage Measurement... 14:40:27 Voltage Offset Correction: v_off_ini = 857.348 uV, v_off_fin = 859.101 uV 14:40:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.148 uVs 14:40:27 Integrated Voltage Measurement... 14:40:36 Voltage Offset Correction: v_off_ini = 885.816 uV, v_off_fin = 883.066 uV 14:40:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.739 uVs 14:40:36 Integrated Voltage Measurement... 14:40:45 Voltage Offset Correction: v_off_ini = 871.918 uV, v_off_fin = 873.772 uV 14:40:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.781 uVs 14:40:45 Integrated Voltage Measurement... 14:40:54 Voltage Offset Correction: v_off_ini = 856.893 uV, v_off_fin = 877.922 uV 14:40:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.772 uVs 14:40:54 Integrated Voltage Measurement... 14:41:03 Voltage Offset Correction: v_off_ini = 846.733 uV, v_off_fin = 847.831 uV 14:41:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.902 uVs 14:41:03 Integrated Voltage Measurement... 14:41:12 Voltage Offset Correction: v_off_ini = 865.192 uV, v_off_fin = 885.278 uV 14:41:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.479 uVs 14:41:16 I1Y Average and RMS of Measurements VT = -190.803 +- 5.956 uVs I1Y = -38.161 +- 1.191 uTm 14:41:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:41:24 Integrated Voltage Measurement... 14:41:33 Voltage Offset Correction: v_off_ini = 877.112 uV, v_off_fin = 882.730 uV 14:41:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.813 uVs 14:41:33 Integrated Voltage Measurement... 14:41:42 Voltage Offset Correction: v_off_ini = 893.244 uV, v_off_fin = 885.807 uV 14:41:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.844 uVs 14:41:42 Integrated Voltage Measurement... 14:41:51 Voltage Offset Correction: v_off_ini = 849.673 uV, v_off_fin = 855.280 uV 14:41:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.698 uVs 14:41:51 Integrated Voltage Measurement... 14:42:00 Voltage Offset Correction: v_off_ini = 856.149 uV, v_off_fin = 871.679 uV 14:42:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.393 uVs 14:42:00 Integrated Voltage Measurement... 14:42:09 Voltage Offset Correction: v_off_ini = 881.977 uV, v_off_fin = 866.802 uV 14:42:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.756 uVs 14:42:09 Integrated Voltage Measurement... 14:42:18 Voltage Offset Correction: v_off_ini = 868.238 uV, v_off_fin = 882.230 uV 14:42:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.074 uVs 14:42:21 I2X Average and RMS of Measurements VT = -111.763 +- 6.883 uVs I2X = 10.282 +- 0.633 uTm^2 14:42:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:42:29 Integrated Voltage Measurement... 14:42:38 Voltage Offset Correction: v_off_ini = 863.069 uV, v_off_fin = 871.049 uV 14:42:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.759 uVs 14:42:38 Integrated Voltage Measurement... 14:42:47 Voltage Offset Correction: v_off_ini = 876.259 uV, v_off_fin = 855.392 uV 14:42:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.393 uVs 14:42:47 Integrated Voltage Measurement... 14:42:56 Voltage Offset Correction: v_off_ini = 866.618 uV, v_off_fin = 874.939 uV 14:42:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.586 uVs 14:42:56 Integrated Voltage Measurement... 14:43:05 Voltage Offset Correction: v_off_ini = 853.806 uV, v_off_fin = 854.642 uV 14:43:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.994 uVs 14:43:05 Integrated Voltage Measurement... 14:43:14 Voltage Offset Correction: v_off_ini = 854.949 uV, v_off_fin = 862.501 uV 14:43:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.080 uVs 14:43:14 Integrated Voltage Measurement... 14:43:23 Voltage Offset Correction: v_off_ini = 871.603 uV, v_off_fin = 880.650 uV 14:43:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.843 uVs 14:43:25 I2Y Average and RMS of Measurements VT = -259.776 +- 4.951 uVs I2Y = -23.899 +- 0.456 uTm^2 14:43:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:43:34 Integrated Voltage Measurement... 14:43:43 Voltage Offset Correction: v_off_ini = 842.117 uV, v_off_fin = 851.506 uV 14:43:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.478 uVs 14:43:43 Integrated Voltage Measurement... 14:43:52 Voltage Offset Correction: v_off_ini = 828.217 uV, v_off_fin = 828.189 uV 14:43:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.396 uVs 14:43:52 Integrated Voltage Measurement... 14:44:01 Voltage Offset Correction: v_off_ini = 821.918 uV, v_off_fin = 826.033 uV 14:44:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.403 uVs 14:44:01 Integrated Voltage Measurement... 14:44:10 Voltage Offset Correction: v_off_ini = 833.627 uV, v_off_fin = 843.310 uV 14:44:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.762 uVs 14:44:10 Integrated Voltage Measurement... 14:44:19 Voltage Offset Correction: v_off_ini = 828.289 uV, v_off_fin = 846.104 uV 14:44:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.031 uVs 14:44:19 Integrated Voltage Measurement... 14:44:28 Voltage Offset Correction: v_off_ini = 831.894 uV, v_off_fin = 819.606 uV 14:44:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.815 uVs 14:44:32 I1X Average and RMS of Measurements VT = -91.814 +- 9.365 uVs I1X = 18.363 +- 1.873 uTm 14:44:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:44:39 Integrated Voltage Measurement... 14:44:48 Voltage Offset Correction: v_off_ini = 802.919 uV, v_off_fin = 803.922 uV 14:44:48 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.250 uVs 14:44:48 Integrated Voltage Measurement... 14:44:57 Voltage Offset Correction: v_off_ini = 846.460 uV, v_off_fin = 839.026 uV 14:44:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.256 uVs 14:44:57 Integrated Voltage Measurement... 14:45:06 Voltage Offset Correction: v_off_ini = 824.388 uV, v_off_fin = 827.055 uV 14:45:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.532 uVs 14:45:06 Integrated Voltage Measurement... 14:45:15 Voltage Offset Correction: v_off_ini = 840.594 uV, v_off_fin = 843.260 uV 14:45:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.273 uVs 14:45:15 Integrated Voltage Measurement... 14:45:24 Voltage Offset Correction: v_off_ini = 830.360 uV, v_off_fin = 827.925 uV 14:45:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.054 uVs 14:45:24 Integrated Voltage Measurement... 14:45:33 Voltage Offset Correction: v_off_ini = 836.166 uV, v_off_fin = 839.240 uV 14:45:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.947 uVs 14:45:37 I1Y Average and RMS of Measurements VT = -191.552 +- 3.165 uVs I1Y = -38.311 +- 0.633 uTm 14:45:43 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:45:45 Integrated Voltage Measurement... 14:45:54 Voltage Offset Correction: v_off_ini = 818.596 uV, v_off_fin = 807.621 uV 14:45:54 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -104.428 uVs 14:45:54 Integrated Voltage Measurement... 14:46:03 Voltage Offset Correction: v_off_ini = 828.445 uV, v_off_fin = 819.091 uV 14:46:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.351 uVs 14:46:03 Integrated Voltage Measurement... 14:46:12 Voltage Offset Correction: v_off_ini = 804.220 uV, v_off_fin = 800.317 uV 14:46:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.701 uVs 14:46:12 Integrated Voltage Measurement... 14:46:21 Voltage Offset Correction: v_off_ini = 811.364 uV, v_off_fin = 826.047 uV 14:46:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.567 uVs 14:46:21 Integrated Voltage Measurement... 14:46:30 Voltage Offset Correction: v_off_ini = 826.035 uV, v_off_fin = 825.201 uV 14:46:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -121.275 uVs 14:46:30 Integrated Voltage Measurement... 14:46:39 Voltage Offset Correction: v_off_ini = 845.194 uV, v_off_fin = 856.256 uV 14:46:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.507 uVs 14:46:42 I2X Average and RMS of Measurements VT = -105.971 +- 4.359 uVs I2X = 9.749 +- 0.401 uTm^2 14:46:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:46:49 Integrated Voltage Measurement... 14:46:58 Voltage Offset Correction: v_off_ini = 846.755 uV, v_off_fin = 823.874 uV 14:46:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.769 uVs 14:46:59 Integrated Voltage Measurement... 14:47:08 Voltage Offset Correction: v_off_ini = 817.172 uV, v_off_fin = 827.074 uV 14:47:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.598 uVs 14:47:08 Integrated Voltage Measurement... 14:47:17 Voltage Offset Correction: v_off_ini = 824.984 uV, v_off_fin = 823.191 uV 14:47:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.351 uVs 14:47:17 Integrated Voltage Measurement... 14:47:26 Voltage Offset Correction: v_off_ini = 809.698 uV, v_off_fin = 818.043 uV 14:47:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.094 uVs 14:47:26 Integrated Voltage Measurement... 14:47:35 Voltage Offset Correction: v_off_ini = 808.796 uV, v_off_fin = 820.664 uV 14:47:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.118 uVs 14:47:35 Integrated Voltage Measurement... 14:47:44 Voltage Offset Correction: v_off_ini = 804.043 uV, v_off_fin = 806.729 uV 14:47:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.245 uVs 14:47:46 I2Y Average and RMS of Measurements VT = -251.363 +- 6.954 uVs I2Y = -23.125 +- 0.640 uTm^2 14:47:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:55 Integrated Voltage Measurement... 14:48:04 Voltage Offset Correction: v_off_ini = 823.919 uV, v_off_fin = 811.013 uV 14:48:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.665 uVs 14:48:04 Integrated Voltage Measurement... 14:48:13 Voltage Offset Correction: v_off_ini = 819.381 uV, v_off_fin = 818.415 uV 14:48:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.185 uVs 14:48:13 Integrated Voltage Measurement... 14:48:22 Voltage Offset Correction: v_off_ini = 816.017 uV, v_off_fin = 808.370 uV 14:48:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.664 uVs 14:48:22 Integrated Voltage Measurement... 14:48:31 Voltage Offset Correction: v_off_ini = 813.683 uV, v_off_fin = 805.078 uV 14:48:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.797 uVs 14:48:31 Integrated Voltage Measurement... 14:48:40 Voltage Offset Correction: v_off_ini = 806.629 uV, v_off_fin = 798.946 uV 14:48:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.147 uVs 14:48:40 Integrated Voltage Measurement... 14:48:49 Voltage Offset Correction: v_off_ini = 828.435 uV, v_off_fin = 812.474 uV 14:48:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.413 uVs 14:48:53 I1X Average and RMS of Measurements VT = -91.145 +- 12.677 uVs I1X = 18.229 +- 2.535 uTm 14:48:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:00 Integrated Voltage Measurement... 14:49:09 Voltage Offset Correction: v_off_ini = 831.969 uV, v_off_fin = 814.423 uV 14:49:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.493 uVs 14:49:09 Integrated Voltage Measurement... 14:49:18 Voltage Offset Correction: v_off_ini = 821.078 uV, v_off_fin = 844.357 uV 14:49:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.084 uVs 14:49:18 Integrated Voltage Measurement... 14:49:27 Voltage Offset Correction: v_off_ini = 823.724 uV, v_off_fin = 818.575 uV 14:49:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.644 uVs 14:49:27 Integrated Voltage Measurement... 14:49:36 Voltage Offset Correction: v_off_ini = 850.728 uV, v_off_fin = 853.839 uV 14:49:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.863 uVs 14:49:36 Integrated Voltage Measurement... 14:49:45 Voltage Offset Correction: v_off_ini = 833.933 uV, v_off_fin = 817.190 uV 14:49:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.858 uVs 14:49:45 Integrated Voltage Measurement... 14:49:54 Voltage Offset Correction: v_off_ini = 828.970 uV, v_off_fin = 851.891 uV 14:49:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.005 uVs 14:49:58 I1Y Average and RMS of Measurements VT = -191.991 +- 5.810 uVs I1Y = -38.398 +- 1.162 uTm 14:50:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:50:06 Integrated Voltage Measurement... 14:50:15 Voltage Offset Correction: v_off_ini = 834.820 uV, v_off_fin = 837.722 uV 14:50:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.707 uVs 14:50:15 Integrated Voltage Measurement... 14:50:24 Voltage Offset Correction: v_off_ini = 842.476 uV, v_off_fin = 848.016 uV 14:50:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.219 uVs 14:50:24 Integrated Voltage Measurement... 14:50:33 Voltage Offset Correction: v_off_ini = 829.209 uV, v_off_fin = 818.260 uV 14:50:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.431 uVs 14:50:33 Integrated Voltage Measurement... 14:50:42 Voltage Offset Correction: v_off_ini = 822.005 uV, v_off_fin = 843.485 uV 14:50:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.573 uVs 14:50:42 Integrated Voltage Measurement... 14:50:51 Voltage Offset Correction: v_off_ini = 834.923 uV, v_off_fin = 811.093 uV 14:50:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.263 uVs 14:50:51 Integrated Voltage Measurement... 14:51:00 Voltage Offset Correction: v_off_ini = 807.495 uV, v_off_fin = 833.742 uV 14:51:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.390 uVs 14:51:03 I2X Average and RMS of Measurements VT = -97.930 +- 10.556 uVs I2X = 9.010 +- 0.971 uTm^2 14:51:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:10 Integrated Voltage Measurement... 14:51:19 Voltage Offset Correction: v_off_ini = 838.393 uV, v_off_fin = 837.326 uV 14:51:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.404 uVs 14:51:19 Integrated Voltage Measurement... 14:51:28 Voltage Offset Correction: v_off_ini = 838.161 uV, v_off_fin = 836.328 uV 14:51:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.864 uVs 14:51:29 Integrated Voltage Measurement... 14:51:38 Voltage Offset Correction: v_off_ini = 842.972 uV, v_off_fin = 852.119 uV 14:51:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.250 uVs 14:51:38 Integrated Voltage Measurement... 14:51:47 Voltage Offset Correction: v_off_ini = 836.097 uV, v_off_fin = 820.585 uV 14:51:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.818 uVs 14:51:47 Integrated Voltage Measurement... 14:51:56 Voltage Offset Correction: v_off_ini = 826.283 uV, v_off_fin = 828.372 uV 14:51:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.990 uVs 14:51:56 Integrated Voltage Measurement... 14:52:05 Voltage Offset Correction: v_off_ini = 832.860 uV, v_off_fin = 833.717 uV 14:52:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.677 uVs 14:52:07 I2Y Average and RMS of Measurements VT = -249.501 +- 6.808 uVs I2Y = -22.954 +- 0.626 uTm^2 14:52:12 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:52:16 Integrated Voltage Measurement... 14:52:25 Voltage Offset Correction: v_off_ini = 820.324 uV, v_off_fin = 828.358 uV 14:52:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.473 uVs 14:52:25 Integrated Voltage Measurement... 14:52:34 Voltage Offset Correction: v_off_ini = 831.615 uV, v_off_fin = 815.579 uV 14:52:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.165 uVs 14:52:34 Integrated Voltage Measurement... 14:52:43 Voltage Offset Correction: v_off_ini = 841.705 uV, v_off_fin = 818.776 uV 14:52:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.361 uVs 14:52:43 Integrated Voltage Measurement... 14:52:52 Voltage Offset Correction: v_off_ini = 817.159 uV, v_off_fin = 825.999 uV 14:52:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.472 uVs 14:52:52 Integrated Voltage Measurement... 14:53:01 Voltage Offset Correction: v_off_ini = 808.603 uV, v_off_fin = 808.286 uV 14:53:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.738 uVs 14:53:01 Integrated Voltage Measurement... 14:53:10 Voltage Offset Correction: v_off_ini = 816.361 uV, v_off_fin = 823.079 uV 14:53:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.356 uVs 14:53:14 I1X Average and RMS of Measurements VT = -75.761 +- 6.046 uVs I1X = 15.152 +- 1.209 uTm 14:53:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:53:21 Integrated Voltage Measurement... 14:53:30 Voltage Offset Correction: v_off_ini = 807.345 uV, v_off_fin = 801.855 uV 14:53:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.341 uVs 14:53:30 Integrated Voltage Measurement... 14:53:39 Voltage Offset Correction: v_off_ini = 809.322 uV, v_off_fin = 823.533 uV 14:53:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.459 uVs 14:53:39 Integrated Voltage Measurement... 14:53:48 Voltage Offset Correction: v_off_ini = 831.284 uV, v_off_fin = 820.871 uV 14:53:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.639 uVs 14:53:48 Integrated Voltage Measurement... 14:53:57 Voltage Offset Correction: v_off_ini = 825.267 uV, v_off_fin = 827.106 uV 14:53:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.091 uVs 14:53:57 Integrated Voltage Measurement... 14:54:06 Voltage Offset Correction: v_off_ini = 807.163 uV, v_off_fin = 809.871 uV 14:54:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.106 uVs 14:54:06 Integrated Voltage Measurement... 14:54:15 Voltage Offset Correction: v_off_ini = 805.509 uV, v_off_fin = 800.577 uV 14:54:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.973 uVs 14:54:19 I1Y Average and RMS of Measurements VT = -184.435 +- 3.833 uVs I1Y = -36.887 +- 0.767 uTm 14:54:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:54:27 Integrated Voltage Measurement... 14:54:36 Voltage Offset Correction: v_off_ini = 799.598 uV, v_off_fin = 819.745 uV 14:54:36 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -79.958 uVs 14:54:36 Integrated Voltage Measurement... 14:54:45 Voltage Offset Correction: v_off_ini = 811.367 uV, v_off_fin = 806.394 uV 14:54:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.338 uVs 14:54:45 Integrated Voltage Measurement... 14:54:54 Voltage Offset Correction: v_off_ini = 791.339 uV, v_off_fin = 770.964 uV 14:54:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.335 uVs 14:54:54 Integrated Voltage Measurement... 14:55:03 Voltage Offset Correction: v_off_ini = 799.631 uV, v_off_fin = 815.953 uV 14:55:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.666 uVs 14:55:03 Integrated Voltage Measurement... 14:55:12 Voltage Offset Correction: v_off_ini = 798.767 uV, v_off_fin = 780.988 uV 14:55:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.490 uVs 14:55:12 Integrated Voltage Measurement... 14:55:21 Voltage Offset Correction: v_off_ini = 787.203 uV, v_off_fin = 789.752 uV 14:55:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.089 uVs 14:55:24 I2X Average and RMS of Measurements VT = -77.479 +- 5.446 uVs I2X = 7.128 +- 0.501 uTm^2 14:55:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:55:31 Integrated Voltage Measurement... 14:55:40 Voltage Offset Correction: v_off_ini = 774.862 uV, v_off_fin = 783.058 uV 14:55:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.318 uVs 14:55:40 Integrated Voltage Measurement... 14:55:49 Voltage Offset Correction: v_off_ini = 780.698 uV, v_off_fin = 786.988 uV 14:55:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.213 uVs 14:55:49 Integrated Voltage Measurement... 14:55:58 Voltage Offset Correction: v_off_ini = 807.210 uV, v_off_fin = 789.991 uV 14:55:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.446 uVs 14:55:58 Integrated Voltage Measurement... 14:56:07 Voltage Offset Correction: v_off_ini = 793.606 uV, v_off_fin = 804.698 uV 14:56:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.540 uVs 14:56:07 Integrated Voltage Measurement... 14:56:16 Voltage Offset Correction: v_off_ini = 792.628 uV, v_off_fin = 794.163 uV 14:56:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.043 uVs 14:56:16 Integrated Voltage Measurement... 14:56:25 Voltage Offset Correction: v_off_ini = 775.969 uV, v_off_fin = 763.799 uV 14:56:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.629 uVs 14:56:28 I2Y Average and RMS of Measurements VT = -243.865 +- 7.607 uVs I2Y = -22.436 +- 0.700 uTm^2 14:56:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:56:37 Integrated Voltage Measurement... 14:56:46 Voltage Offset Correction: v_off_ini = 793.619 uV, v_off_fin = 787.944 uV 14:56:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.854 uVs 14:56:46 Integrated Voltage Measurement... 14:56:55 Voltage Offset Correction: v_off_ini = 792.337 uV, v_off_fin = 783.664 uV 14:56:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.135 uVs 14:56:55 Integrated Voltage Measurement... 14:57:04 Voltage Offset Correction: v_off_ini = 785.118 uV, v_off_fin = 773.238 uV 14:57:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.005 uVs 14:57:04 Integrated Voltage Measurement... 14:57:13 Voltage Offset Correction: v_off_ini = 790.282 uV, v_off_fin = 776.216 uV 14:57:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.381 uVs 14:57:13 Integrated Voltage Measurement... 14:57:22 Voltage Offset Correction: v_off_ini = 789.984 uV, v_off_fin = 770.327 uV 14:57:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.336 uVs 14:57:22 Integrated Voltage Measurement... 14:57:31 Voltage Offset Correction: v_off_ini = 759.267 uV, v_off_fin = 756.495 uV 14:57:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.975 uVs 14:57:35 I1X Average and RMS of Measurements VT = -65.948 +- 5.404 uVs I1X = 13.190 +- 1.081 uTm 14:57:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:57:42 Integrated Voltage Measurement... 14:57:51 Voltage Offset Correction: v_off_ini = 765.434 uV, v_off_fin = 763.970 uV 14:57:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.854 uVs 14:57:51 Integrated Voltage Measurement... 14:58:00 Voltage Offset Correction: v_off_ini = 781.529 uV, v_off_fin = 780.657 uV 14:58:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.875 uVs 14:58:00 Integrated Voltage Measurement... 14:58:09 Voltage Offset Correction: v_off_ini = 781.261 uV, v_off_fin = 761.500 uV 14:58:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.332 uVs 14:58:09 Integrated Voltage Measurement... 14:58:17 Voltage Offset Correction: v_off_ini = 775.661 uV, v_off_fin = 793.361 uV 14:58:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.191 uVs 14:58:18 Integrated Voltage Measurement... 14:58:26 Voltage Offset Correction: v_off_ini = 787.550 uV, v_off_fin = 786.486 uV 14:58:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.044 uVs 14:58:27 Integrated Voltage Measurement... 14:58:35 Voltage Offset Correction: v_off_ini = 784.567 uV, v_off_fin = 789.851 uV 14:58:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.500 uVs 14:58:40 I1Y Average and RMS of Measurements VT = -181.966 +- 4.533 uVs I1Y = -36.393 +- 0.907 uTm 14:58:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:58:47 Integrated Voltage Measurement... 14:58:56 Voltage Offset Correction: v_off_ini = 794.038 uV, v_off_fin = 786.383 uV 14:58:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.249 uVs 14:58:56 Integrated Voltage Measurement... 14:59:05 Voltage Offset Correction: v_off_ini = 814.298 uV, v_off_fin = 813.630 uV 14:59:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.045 uVs 14:59:05 Integrated Voltage Measurement... 14:59:14 Voltage Offset Correction: v_off_ini = 796.887 uV, v_off_fin = 789.995 uV 14:59:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.582 uVs 14:59:14 Integrated Voltage Measurement... 14:59:23 Voltage Offset Correction: v_off_ini = 791.138 uV, v_off_fin = 807.288 uV 14:59:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.571 uVs 14:59:23 Integrated Voltage Measurement... 14:59:32 Voltage Offset Correction: v_off_ini = 798.464 uV, v_off_fin = 802.096 uV 14:59:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.542 uVs 14:59:33 Integrated Voltage Measurement... 14:59:41 Voltage Offset Correction: v_off_ini = 809.388 uV, v_off_fin = 821.258 uV 14:59:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.399 uVs 14:59:44 I2X Average and RMS of Measurements VT = -80.731 +- 1.828 uVs I2X = 7.427 +- 0.168 uTm^2 14:59:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:59:52 Integrated Voltage Measurement... 15:00:01 Voltage Offset Correction: v_off_ini = 815.681 uV, v_off_fin = 826.807 uV 15:00:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.656 uVs 15:00:01 Integrated Voltage Measurement... 15:00:10 Voltage Offset Correction: v_off_ini = 825.044 uV, v_off_fin = 818.884 uV 15:00:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.858 uVs 15:00:10 Integrated Voltage Measurement... 15:00:19 Voltage Offset Correction: v_off_ini = 838.692 uV, v_off_fin = 837.522 uV 15:00:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.377 uVs 15:00:19 Integrated Voltage Measurement... 15:00:28 Voltage Offset Correction: v_off_ini = 823.911 uV, v_off_fin = 826.997 uV 15:00:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.544 uVs 15:00:28 Integrated Voltage Measurement... 15:00:37 Voltage Offset Correction: v_off_ini = 832.255 uV, v_off_fin = 823.324 uV 15:00:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.042 uVs 15:00:37 Integrated Voltage Measurement... 15:00:46 Voltage Offset Correction: v_off_ini = 842.734 uV, v_off_fin = 834.047 uV 15:00:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.325 uVs 15:00:48 I2Y Average and RMS of Measurements VT = -242.634 +- 7.330 uVs I2Y = -22.322 +- 0.674 uTm^2 15:00:56 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:01:00 Integrated Voltage Measurement... 15:01:09 Voltage Offset Correction: v_off_ini = 832.005 uV, v_off_fin = 830.839 uV 15:01:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.802 uVs 15:01:09 Integrated Voltage Measurement... 15:01:18 Voltage Offset Correction: v_off_ini = 826.843 uV, v_off_fin = 831.865 uV 15:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.655 uVs 15:01:18 Integrated Voltage Measurement... 15:01:27 Voltage Offset Correction: v_off_ini = 820.776 uV, v_off_fin = 839.052 uV 15:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.424 uVs 15:01:27 Integrated Voltage Measurement... 15:01:36 Voltage Offset Correction: v_off_ini = 829.248 uV, v_off_fin = 832.120 uV 15:01:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.547 uVs 15:01:36 Integrated Voltage Measurement... 15:01:45 Voltage Offset Correction: v_off_ini = 848.569 uV, v_off_fin = 845.862 uV 15:01:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.285 uVs 15:01:45 Integrated Voltage Measurement... 15:01:54 Voltage Offset Correction: v_off_ini = 817.856 uV, v_off_fin = 831.562 uV 15:01:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.959 uVs 15:01:58 I1X Average and RMS of Measurements VT = -80.112 +- 11.307 uVs I1X = 16.023 +- 2.262 uTm 15:02:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:02:05 Integrated Voltage Measurement... 15:02:14 Voltage Offset Correction: v_off_ini = 820.976 uV, v_off_fin = 828.522 uV 15:02:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.285 uVs 15:02:14 Integrated Voltage Measurement... 15:02:23 Voltage Offset Correction: v_off_ini = 813.405 uV, v_off_fin = 820.472 uV 15:02:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.033 uVs 15:02:23 Integrated Voltage Measurement... 15:02:32 Voltage Offset Correction: v_off_ini = 825.650 uV, v_off_fin = 814.328 uV 15:02:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.400 uVs 15:02:32 Integrated Voltage Measurement... 15:02:41 Voltage Offset Correction: v_off_ini = 830.502 uV, v_off_fin = 845.525 uV 15:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.054 uVs 15:02:41 Integrated Voltage Measurement... 15:02:50 Voltage Offset Correction: v_off_ini = 830.864 uV, v_off_fin = 819.452 uV 15:02:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.794 uVs 15:02:50 Integrated Voltage Measurement... 15:02:59 Voltage Offset Correction: v_off_ini = 824.640 uV, v_off_fin = 826.801 uV 15:02:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.535 uVs 15:03:03 I1Y Average and RMS of Measurements VT = -193.684 +- 2.447 uVs I1Y = -38.737 +- 0.489 uTm 15:03:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:03:08 Integrated Voltage Measurement... 15:03:17 Voltage Offset Correction: v_off_ini = 810.583 uV, v_off_fin = 811.424 uV 15:03:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.295 uVs 15:03:17 Integrated Voltage Measurement... 15:03:26 Voltage Offset Correction: v_off_ini = 820.363 uV, v_off_fin = 838.025 uV 15:03:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.166 uVs 15:03:26 Integrated Voltage Measurement... 15:03:35 Voltage Offset Correction: v_off_ini = 828.264 uV, v_off_fin = 815.077 uV 15:03:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.141 uVs 15:03:35 Integrated Voltage Measurement... 15:03:44 Voltage Offset Correction: v_off_ini = 825.339 uV, v_off_fin = 810.162 uV 15:03:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.489 uVs 15:03:44 Integrated Voltage Measurement... 15:03:53 Voltage Offset Correction: v_off_ini = 803.234 uV, v_off_fin = 799.856 uV 15:03:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.854 uVs 15:03:53 Integrated Voltage Measurement... 15:04:02 Voltage Offset Correction: v_off_ini = 792.976 uV, v_off_fin = 826.970 uV 15:04:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.862 uVs 15:04:05 I2X Average and RMS of Measurements VT = -101.468 +- 4.380 uVs I2X = 9.335 +- 0.403 uTm^2 15:04:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:04:10 Integrated Voltage Measurement... 15:04:19 Voltage Offset Correction: v_off_ini = 797.549 uV, v_off_fin = 807.120 uV 15:04:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.919 uVs 15:04:19 Integrated Voltage Measurement... 15:04:28 Voltage Offset Correction: v_off_ini = 800.487 uV, v_off_fin = 805.659 uV 15:04:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.530 uVs 15:04:28 Integrated Voltage Measurement... 15:04:37 Voltage Offset Correction: v_off_ini = 804.133 uV, v_off_fin = 797.360 uV 15:04:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.590 uVs 15:04:37 Integrated Voltage Measurement... 15:04:46 Voltage Offset Correction: v_off_ini = 822.261 uV, v_off_fin = 799.357 uV 15:04:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.750 uVs 15:04:46 Integrated Voltage Measurement... 15:04:55 Voltage Offset Correction: v_off_ini = 817.686 uV, v_off_fin = 810.925 uV 15:04:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.455 uVs 15:04:55 Integrated Voltage Measurement... 15:05:04 Voltage Offset Correction: v_off_ini = 803.223 uV, v_off_fin = 800.470 uV 15:05:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.601 uVs 15:05:06 I2Y Average and RMS of Measurements VT = -259.141 +- 1.946 uVs I2Y = -23.841 +- 0.179 uTm^2 15:05:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:05:15 Integrated Voltage Measurement... 15:05:24 Voltage Offset Correction: v_off_ini = 800.513 uV, v_off_fin = 819.142 uV 15:05:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.678 uVs 15:05:24 Integrated Voltage Measurement... 15:05:33 Voltage Offset Correction: v_off_ini = 831.780 uV, v_off_fin = 835.223 uV 15:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.918 uVs 15:05:33 Integrated Voltage Measurement... 15:05:42 Voltage Offset Correction: v_off_ini = 831.378 uV, v_off_fin = 832.746 uV 15:05:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.404 uVs 15:05:42 Integrated Voltage Measurement... 15:05:51 Voltage Offset Correction: v_off_ini = 836.405 uV, v_off_fin = 833.571 uV 15:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.593 uVs 15:05:51 Integrated Voltage Measurement... 15:06:00 Voltage Offset Correction: v_off_ini = 826.771 uV, v_off_fin = 821.724 uV 15:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.080 uVs 15:06:00 Integrated Voltage Measurement... 15:06:09 Voltage Offset Correction: v_off_ini = 808.990 uV, v_off_fin = 822.004 uV 15:06:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.289 uVs 15:06:13 I1X Average and RMS of Measurements VT = -79.494 +- 8.023 uVs I1X = 15.899 +- 1.605 uTm 15:06:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:06:20 Integrated Voltage Measurement... 15:06:28 Voltage Offset Correction: v_off_ini = 834.537 uV, v_off_fin = 806.300 uV 15:06:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.518 uVs 15:06:29 Integrated Voltage Measurement... 15:06:37 Voltage Offset Correction: v_off_ini = 806.617 uV, v_off_fin = 808.518 uV 15:06:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.605 uVs 15:06:38 Integrated Voltage Measurement... 15:06:46 Voltage Offset Correction: v_off_ini = 789.782 uV, v_off_fin = 795.828 uV 15:06:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.155 uVs 15:06:47 Integrated Voltage Measurement... 15:06:55 Voltage Offset Correction: v_off_ini = 807.070 uV, v_off_fin = 798.036 uV 15:06:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.991 uVs 15:06:55 Integrated Voltage Measurement... 15:07:04 Voltage Offset Correction: v_off_ini = 791.243 uV, v_off_fin = 799.378 uV 15:07:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.252 uVs 15:07:04 Integrated Voltage Measurement... 15:07:13 Voltage Offset Correction: v_off_ini = 809.952 uV, v_off_fin = 820.616 uV 15:07:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.242 uVs 15:07:18 I1Y Average and RMS of Measurements VT = -185.794 +- 6.317 uVs I1Y = -37.159 +- 1.263 uTm 15:07:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:07:23 Integrated Voltage Measurement... 15:07:32 Voltage Offset Correction: v_off_ini = 764.803 uV, v_off_fin = 786.596 uV 15:07:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.163 uVs 15:07:32 Integrated Voltage Measurement... 15:07:41 Voltage Offset Correction: v_off_ini = 805.027 uV, v_off_fin = 818.722 uV 15:07:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.175 uVs 15:07:41 Integrated Voltage Measurement... 15:07:50 Voltage Offset Correction: v_off_ini = 813.551 uV, v_off_fin = 808.274 uV 15:07:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.219 uVs 15:07:50 Integrated Voltage Measurement... 15:07:59 Voltage Offset Correction: v_off_ini = 791.731 uV, v_off_fin = 800.906 uV 15:07:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.031 uVs 15:07:59 Integrated Voltage Measurement... 15:08:08 Voltage Offset Correction: v_off_ini = 805.950 uV, v_off_fin = 770.818 uV 15:08:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.577 uVs 15:08:08 Integrated Voltage Measurement... 15:08:17 Voltage Offset Correction: v_off_ini = 767.773 uV, v_off_fin = 801.183 uV 15:08:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.810 uVs 15:08:19 I2X Average and RMS of Measurements VT = -105.829 +- 11.483 uVs I2X = 9.737 +- 1.056 uTm^2 15:08:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:08:24 Integrated Voltage Measurement... 15:08:33 Voltage Offset Correction: v_off_ini = 780.927 uV, v_off_fin = 777.770 uV 15:08:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.968 uVs 15:08:33 Integrated Voltage Measurement... 15:08:42 Voltage Offset Correction: v_off_ini = 768.626 uV, v_off_fin = 767.173 uV 15:08:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.138 uVs 15:08:42 Integrated Voltage Measurement... 15:08:51 Voltage Offset Correction: v_off_ini = 767.144 uV, v_off_fin = 775.937 uV 15:08:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.385 uVs 15:08:51 Integrated Voltage Measurement... 15:09:00 Voltage Offset Correction: v_off_ini = 782.944 uV, v_off_fin = 784.008 uV 15:09:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.210 uVs 15:09:00 Integrated Voltage Measurement... 15:09:09 Voltage Offset Correction: v_off_ini = 784.110 uV, v_off_fin = 780.492 uV 15:09:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.114 uVs 15:09:09 Integrated Voltage Measurement... 15:09:18 Voltage Offset Correction: v_off_ini = 779.617 uV, v_off_fin = 782.099 uV 15:09:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.162 uVs 15:09:21 I2Y Average and RMS of Measurements VT = -255.830 +- 6.980 uVs I2Y = -23.536 +- 0.642 uTm^2 15:09:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:29 Integrated Voltage Measurement... 15:09:38 Voltage Offset Correction: v_off_ini = 780.473 uV, v_off_fin = 784.693 uV 15:09:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.235 uVs 15:09:38 Integrated Voltage Measurement... 15:09:47 Voltage Offset Correction: v_off_ini = 782.357 uV, v_off_fin = 803.904 uV 15:09:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.766 uVs 15:09:47 Integrated Voltage Measurement... 15:09:56 Voltage Offset Correction: v_off_ini = 795.592 uV, v_off_fin = 806.093 uV 15:09:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.365 uVs 15:09:56 Integrated Voltage Measurement... 15:10:05 Voltage Offset Correction: v_off_ini = 813.378 uV, v_off_fin = 784.910 uV 15:10:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.819 uVs 15:10:05 Integrated Voltage Measurement... 15:10:14 Voltage Offset Correction: v_off_ini = 783.916 uV, v_off_fin = 796.461 uV 15:10:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.354 uVs 15:10:14 Integrated Voltage Measurement... 15:10:23 Voltage Offset Correction: v_off_ini = 780.955 uV, v_off_fin = 776.397 uV 15:10:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.941 uVs 15:10:27 I1X Average and RMS of Measurements VT = -88.247 +- 9.305 uVs I1X = 17.649 +- 1.861 uTm 15:10:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:34 Integrated Voltage Measurement... 15:10:43 Voltage Offset Correction: v_off_ini = 784.382 uV, v_off_fin = 779.131 uV 15:10:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -192.890 uVs 15:10:43 Integrated Voltage Measurement... 15:10:52 Voltage Offset Correction: v_off_ini = 768.278 uV, v_off_fin = 786.569 uV 15:10:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.005 uVs 15:10:52 Integrated Voltage Measurement... 15:11:01 Voltage Offset Correction: v_off_ini = 788.852 uV, v_off_fin = 782.801 uV 15:11:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.527 uVs 15:11:01 Integrated Voltage Measurement... 15:11:10 Voltage Offset Correction: v_off_ini = 759.001 uV, v_off_fin = 787.286 uV 15:11:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.321 uVs 15:11:10 Integrated Voltage Measurement... 15:11:19 Voltage Offset Correction: v_off_ini = 783.856 uV, v_off_fin = 792.570 uV 15:11:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.948 uVs 15:11:19 Integrated Voltage Measurement... 15:11:28 Voltage Offset Correction: v_off_ini = 791.193 uV, v_off_fin = 823.276 uV 15:11:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.675 uVs 15:11:32 I1Y Average and RMS of Measurements VT = -187.228 +- 6.173 uVs I1Y = -37.446 +- 1.235 uTm 15:11:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:37 Integrated Voltage Measurement... 15:11:46 Voltage Offset Correction: v_off_ini = 782.815 uV, v_off_fin = 785.909 uV 15:11:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.292 uVs 15:11:46 Integrated Voltage Measurement... 15:11:55 Voltage Offset Correction: v_off_ini = 783.842 uV, v_off_fin = 795.988 uV 15:11:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.307 uVs 15:11:55 Integrated Voltage Measurement... 15:12:04 Voltage Offset Correction: v_off_ini = 774.773 uV, v_off_fin = 778.665 uV 15:12:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.266 uVs 15:12:04 Integrated Voltage Measurement... 15:12:13 Voltage Offset Correction: v_off_ini = 798.324 uV, v_off_fin = 810.022 uV 15:12:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.139 uVs 15:12:14 Integrated Voltage Measurement... 15:12:22 Voltage Offset Correction: v_off_ini = 796.238 uV, v_off_fin = 788.163 uV 15:12:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.319 uVs 15:12:23 Integrated Voltage Measurement... 15:12:31 Voltage Offset Correction: v_off_ini = 785.424 uV, v_off_fin = 787.968 uV 15:12:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.625 uVs 15:12:34 I2X Average and RMS of Measurements VT = -107.325 +- 7.024 uVs I2X = 9.874 +- 0.646 uTm^2 15:12:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:12:39 Integrated Voltage Measurement... 15:12:48 Voltage Offset Correction: v_off_ini = 802.089 uV, v_off_fin = 793.836 uV 15:12:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.390 uVs 15:12:48 Integrated Voltage Measurement... 15:12:57 Voltage Offset Correction: v_off_ini = 789.112 uV, v_off_fin = 801.192 uV 15:12:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.885 uVs 15:12:57 Integrated Voltage Measurement... 15:13:06 Voltage Offset Correction: v_off_ini = 797.881 uV, v_off_fin = 801.123 uV 15:13:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.925 uVs 15:13:06 Integrated Voltage Measurement... 15:13:15 Voltage Offset Correction: v_off_ini = 789.493 uV, v_off_fin = 793.221 uV 15:13:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.797 uVs 15:13:15 Integrated Voltage Measurement... 15:13:24 Voltage Offset Correction: v_off_ini = 773.982 uV, v_off_fin = 801.779 uV 15:13:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.798 uVs 15:13:24 Integrated Voltage Measurement... 15:13:33 Voltage Offset Correction: v_off_ini = 786.121 uV, v_off_fin = 807.123 uV 15:13:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.058 uVs 15:13:36 I2Y Average and RMS of Measurements VT = -247.975 +- 2.773 uVs I2Y = -22.814 +- 0.255 uTm^2 15:13:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:13:44 Integrated Voltage Measurement... 15:13:53 Voltage Offset Correction: v_off_ini = 786.155 uV, v_off_fin = 791.453 uV 15:13:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.751 uVs 15:13:53 Integrated Voltage Measurement... 15:14:02 Voltage Offset Correction: v_off_ini = 777.838 uV, v_off_fin = 789.088 uV 15:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.960 uVs 15:14:02 Integrated Voltage Measurement... 15:14:11 Voltage Offset Correction: v_off_ini = 776.678 uV, v_off_fin = 789.358 uV 15:14:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.586 uVs 15:14:11 Integrated Voltage Measurement... 15:14:20 Voltage Offset Correction: v_off_ini = 790.881 uV, v_off_fin = 788.249 uV 15:14:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.736 uVs 15:14:20 Integrated Voltage Measurement... 15:14:29 Voltage Offset Correction: v_off_ini = 809.550 uV, v_off_fin = 804.357 uV 15:14:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.458 uVs 15:14:29 Integrated Voltage Measurement... 15:14:38 Voltage Offset Correction: v_off_ini = 818.398 uV, v_off_fin = 810.068 uV 15:14:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.580 uVs 15:14:42 I1X Average and RMS of Measurements VT = -63.512 +- 10.297 uVs I1X = 12.703 +- 2.060 uTm 15:14:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:14:49 Integrated Voltage Measurement... 15:14:58 Voltage Offset Correction: v_off_ini = 833.656 uV, v_off_fin = 838.113 uV 15:14:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -185.049 uVs 15:14:58 Integrated Voltage Measurement... 15:15:07 Voltage Offset Correction: v_off_ini = 822.487 uV, v_off_fin = 830.985 uV 15:15:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.878 uVs 15:15:07 Integrated Voltage Measurement... 15:15:16 Voltage Offset Correction: v_off_ini = 797.929 uV, v_off_fin = 782.450 uV 15:15:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.376 uVs 15:15:16 Integrated Voltage Measurement... 15:15:25 Voltage Offset Correction: v_off_ini = 798.906 uV, v_off_fin = 811.724 uV 15:15:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.981 uVs 15:15:25 Integrated Voltage Measurement... 15:15:34 Voltage Offset Correction: v_off_ini = 826.536 uV, v_off_fin = 797.394 uV 15:15:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.574 uVs 15:15:34 Integrated Voltage Measurement... 15:15:43 Voltage Offset Correction: v_off_ini = 801.529 uV, v_off_fin = 794.944 uV 15:15:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.340 uVs 15:15:47 I1Y Average and RMS of Measurements VT = -173.533 +- 4.252 uVs I1Y = -34.707 +- 0.850 uTm 15:15:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:15:52 Integrated Voltage Measurement... 15:16:01 Voltage Offset Correction: v_off_ini = 776.876 uV, v_off_fin = 777.292 uV 15:16:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.049 uVs 15:16:01 Integrated Voltage Measurement... 15:16:10 Voltage Offset Correction: v_off_ini = 764.707 uV, v_off_fin = 782.220 uV 15:16:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.106 uVs 15:16:10 Integrated Voltage Measurement... 15:16:19 Voltage Offset Correction: v_off_ini = 777.773 uV, v_off_fin = 770.071 uV 15:16:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.293 uVs 15:16:19 Integrated Voltage Measurement... 15:16:28 Voltage Offset Correction: v_off_ini = 787.245 uV, v_off_fin = 801.036 uV 15:16:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.092 uVs 15:16:28 Integrated Voltage Measurement... 15:16:37 Voltage Offset Correction: v_off_ini = 806.594 uV, v_off_fin = 794.065 uV 15:16:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.707 uVs 15:16:37 Integrated Voltage Measurement... 15:16:46 Voltage Offset Correction: v_off_ini = 810.004 uV, v_off_fin = 803.219 uV 15:16:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.765 uVs 15:16:49 I2X Average and RMS of Measurements VT = -85.669 +- 11.478 uVs I2X = 7.882 +- 1.056 uTm^2 15:16:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:16:54 Integrated Voltage Measurement... 15:17:03 Voltage Offset Correction: v_off_ini = 799.622 uV, v_off_fin = 783.840 uV 15:17:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.304 uVs 15:17:03 Integrated Voltage Measurement... 15:17:12 Voltage Offset Correction: v_off_ini = 788.351 uV, v_off_fin = 794.418 uV 15:17:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.043 uVs 15:17:12 Integrated Voltage Measurement... 15:17:21 Voltage Offset Correction: v_off_ini = 809.172 uV, v_off_fin = 800.423 uV 15:17:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -229.189 uVs 15:17:21 Integrated Voltage Measurement... 15:17:30 Voltage Offset Correction: v_off_ini = 816.303 uV, v_off_fin = 825.856 uV 15:17:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.522 uVs 15:17:30 Integrated Voltage Measurement... 15:17:39 Voltage Offset Correction: v_off_ini = 818.436 uV, v_off_fin = 838.580 uV 15:17:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.359 uVs 15:17:39 Integrated Voltage Measurement... 15:17:48 Voltage Offset Correction: v_off_ini = 825.835 uV, v_off_fin = 838.394 uV 15:17:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.656 uVs 15:17:50 I2Y Average and RMS of Measurements VT = -232.512 +- 2.129 uVs I2Y = -21.391 +- 0.196 uTm^2 15:17:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:17:58 Integrated Voltage Measurement... 15:18:07 Voltage Offset Correction: v_off_ini = 824.345 uV, v_off_fin = 835.016 uV 15:18:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -78.386 uVs 15:18:07 Integrated Voltage Measurement... 15:18:16 Voltage Offset Correction: v_off_ini = 833.668 uV, v_off_fin = 825.062 uV 15:18:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.245 uVs 15:18:17 Integrated Voltage Measurement... 15:18:25 Voltage Offset Correction: v_off_ini = 837.620 uV, v_off_fin = 802.299 uV 15:18:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.460 uVs 15:18:26 Integrated Voltage Measurement... 15:18:34 Voltage Offset Correction: v_off_ini = 822.238 uV, v_off_fin = 834.984 uV 15:18:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.279 uVs 15:18:35 Integrated Voltage Measurement... 15:18:43 Voltage Offset Correction: v_off_ini = 832.798 uV, v_off_fin = 828.739 uV 15:18:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.673 uVs 15:18:44 Integrated Voltage Measurement... 15:18:52 Voltage Offset Correction: v_off_ini = 830.013 uV, v_off_fin = 817.434 uV 15:18:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.233 uVs 15:18:57 I1X Average and RMS of Measurements VT = -73.879 +- 4.105 uVs I1X = 14.776 +- 0.821 uTm 15:18:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:19:03 Integrated Voltage Measurement... 15:19:12 Voltage Offset Correction: v_off_ini = 832.722 uV, v_off_fin = 834.260 uV 15:19:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -178.928 uVs 15:19:12 Integrated Voltage Measurement... 15:19:21 Voltage Offset Correction: v_off_ini = 822.411 uV, v_off_fin = 832.294 uV 15:19:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.348 uVs 15:19:21 Integrated Voltage Measurement... 15:19:30 Voltage Offset Correction: v_off_ini = 853.886 uV, v_off_fin = 827.200 uV 15:19:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.624 uVs 15:19:30 Integrated Voltage Measurement... 15:19:39 Voltage Offset Correction: v_off_ini = 831.129 uV, v_off_fin = 854.068 uV 15:19:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.241 uVs 15:19:39 Integrated Voltage Measurement... 15:19:48 Voltage Offset Correction: v_off_ini = 832.060 uV, v_off_fin = 827.142 uV 15:19:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.176 uVs 15:19:48 Integrated Voltage Measurement... 15:19:57 Voltage Offset Correction: v_off_ini = 833.918 uV, v_off_fin = 823.103 uV 15:19:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.131 uVs 15:20:02 I1Y Average and RMS of Measurements VT = -177.241 +- 2.769 uVs I1Y = -35.449 +- 0.553 uTm 15:20:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:20:07 Integrated Voltage Measurement... 15:20:16 Voltage Offset Correction: v_off_ini = 831.621 uV, v_off_fin = 831.060 uV 15:20:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.423 uVs 15:20:16 Integrated Voltage Measurement... 15:20:25 Voltage Offset Correction: v_off_ini = 839.157 uV, v_off_fin = 855.213 uV 15:20:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.772 uVs 15:20:25 Integrated Voltage Measurement... 15:20:34 Voltage Offset Correction: v_off_ini = 843.687 uV, v_off_fin = 848.620 uV 15:20:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.762 uVs 15:20:34 Integrated Voltage Measurement... 15:20:43 Voltage Offset Correction: v_off_ini = 863.315 uV, v_off_fin = 848.765 uV 15:20:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.863 uVs 15:20:43 Integrated Voltage Measurement... 15:20:52 Voltage Offset Correction: v_off_ini = 839.163 uV, v_off_fin = 829.583 uV 15:20:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.237 uVs 15:20:52 Integrated Voltage Measurement... 15:21:01 Voltage Offset Correction: v_off_ini = 840.183 uV, v_off_fin = 853.015 uV 15:21:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.497 uVs 15:21:03 I2X Average and RMS of Measurements VT = -87.759 +- 3.260 uVs I2X = 8.074 +- 0.300 uTm^2 15:21:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:21:08 Integrated Voltage Measurement... 15:21:17 Voltage Offset Correction: v_off_ini = 832.053 uV, v_off_fin = 833.951 uV 15:21:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.789 uVs 15:21:17 Integrated Voltage Measurement... 15:21:26 Voltage Offset Correction: v_off_ini = 837.241 uV, v_off_fin = 844.553 uV 15:21:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.664 uVs 15:21:27 Integrated Voltage Measurement... 15:21:36 Voltage Offset Correction: v_off_ini = 835.812 uV, v_off_fin = 811.018 uV 15:21:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.850 uVs 15:21:36 Integrated Voltage Measurement... 15:21:45 Voltage Offset Correction: v_off_ini = 804.373 uV, v_off_fin = 824.155 uV 15:21:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.863 uVs 15:21:45 Integrated Voltage Measurement... 15:21:54 Voltage Offset Correction: v_off_ini = 817.853 uV, v_off_fin = 844.688 uV 15:21:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.266 uVs 15:21:54 Integrated Voltage Measurement... 15:22:03 Voltage Offset Correction: v_off_ini = 834.389 uV, v_off_fin = 836.036 uV 15:22:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 236.505 uVs 15:22:05 I2Y Average and RMS of Measurements VT = -238.323 +- 5.453 uVs I2Y = -21.926 +- 0.502 uTm^2 15:22:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:22:25 Integrated Voltage Measurement... 15:22:34 Voltage Offset Correction: v_off_ini = 835.357 uV, v_off_fin = 826.625 uV 15:22:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.367 uVs 15:22:34 Integrated Voltage Measurement... 15:22:43 Voltage Offset Correction: v_off_ini = 820.985 uV, v_off_fin = 816.445 uV 15:22:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.976 uVs 15:22:43 Integrated Voltage Measurement... 15:22:52 Voltage Offset Correction: v_off_ini = 840.565 uV, v_off_fin = 840.886 uV 15:22:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.066 uVs 15:22:52 Integrated Voltage Measurement... 15:23:01 Voltage Offset Correction: v_off_ini = 846.008 uV, v_off_fin = 838.593 uV 15:23:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.825 uVs 15:23:02 Integrated Voltage Measurement... 15:23:10 Voltage Offset Correction: v_off_ini = 847.762 uV, v_off_fin = 845.368 uV 15:23:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.571 uVs 15:23:11 Integrated Voltage Measurement... 15:23:19 Voltage Offset Correction: v_off_ini = 822.631 uV, v_off_fin = 846.805 uV 15:23:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 120.197 uVs 15:23:24 I1X Average and RMS of Measurements VT = -102.833 +- 6.893 uVs I1X = 20.567 +- 1.379 uTm 15:23:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:23:30 Integrated Voltage Measurement... 15:23:39 Voltage Offset Correction: v_off_ini = 856.407 uV, v_off_fin = 831.738 uV 15:23:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.126 uVs 15:23:40 Integrated Voltage Measurement... 15:23:48 Voltage Offset Correction: v_off_ini = 824.363 uV, v_off_fin = 841.146 uV 15:23:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.318 uVs 15:23:49 Integrated Voltage Measurement... 15:23:57 Voltage Offset Correction: v_off_ini = 836.087 uV, v_off_fin = 830.093 uV 15:23:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.306 uVs 15:23:57 Integrated Voltage Measurement... 15:24:06 Voltage Offset Correction: v_off_ini = 833.765 uV, v_off_fin = 827.430 uV 15:24:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.172 uVs 15:24:07 Integrated Voltage Measurement... 15:24:15 Voltage Offset Correction: v_off_ini = 852.918 uV, v_off_fin = 832.454 uV 15:24:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.265 uVs 15:24:16 Integrated Voltage Measurement... 15:24:24 Voltage Offset Correction: v_off_ini = 872.686 uV, v_off_fin = 862.919 uV 15:24:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.550 uVs 15:24:29 I1Y Average and RMS of Measurements VT = -184.790 +- 4.770 uVs I1Y = -36.958 +- 0.954 uTm 15:24:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:24:36 Integrated Voltage Measurement... 15:24:45 Voltage Offset Correction: v_off_ini = 827.213 uV, v_off_fin = 825.806 uV 15:24:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.741 uVs 15:24:45 Integrated Voltage Measurement... 15:24:54 Voltage Offset Correction: v_off_ini = 842.501 uV, v_off_fin = 863.580 uV 15:24:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.163 uVs 15:24:54 Integrated Voltage Measurement... 15:25:03 Voltage Offset Correction: v_off_ini = 852.640 uV, v_off_fin = 851.162 uV 15:25:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.387 uVs 15:25:04 Integrated Voltage Measurement... 15:25:13 Voltage Offset Correction: v_off_ini = 861.960 uV, v_off_fin = 867.733 uV 15:25:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.798 uVs 15:25:13 Integrated Voltage Measurement... 15:25:22 Voltage Offset Correction: v_off_ini = 870.298 uV, v_off_fin = 867.237 uV 15:25:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.269 uVs 15:25:22 Integrated Voltage Measurement... 15:25:31 Voltage Offset Correction: v_off_ini = 866.687 uV, v_off_fin = 873.758 uV 15:25:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.527 uVs 15:25:33 I2X Average and RMS of Measurements VT = -124.981 +- 7.566 uVs I2X = 11.498 +- 0.696 uTm^2 15:25:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:25:41 Integrated Voltage Measurement... 15:25:50 Voltage Offset Correction: v_off_ini = 841.815 uV, v_off_fin = 855.361 uV 15:25:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.813 uVs 15:25:50 Integrated Voltage Measurement... 15:25:59 Voltage Offset Correction: v_off_ini = 875.122 uV, v_off_fin = 902.946 uV 15:25:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.091 uVs 15:25:59 Integrated Voltage Measurement... 15:26:08 Voltage Offset Correction: v_off_ini = 882.999 uV, v_off_fin = 879.364 uV 15:26:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.825 uVs 15:26:08 Integrated Voltage Measurement... 15:26:17 Voltage Offset Correction: v_off_ini = 886.727 uV, v_off_fin = 892.686 uV 15:26:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.881 uVs 15:26:17 Integrated Voltage Measurement... 15:26:26 Voltage Offset Correction: v_off_ini = 892.015 uV, v_off_fin = 889.399 uV 15:26:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.541 uVs 15:26:26 Integrated Voltage Measurement... 15:26:35 Voltage Offset Correction: v_off_ini = 879.605 uV, v_off_fin = 893.198 uV 15:26:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.928 uVs 15:26:37 I2Y Average and RMS of Measurements VT = -247.847 +- 8.157 uVs I2Y = -22.802 +- 0.750 uTm^2 15:26:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:26:46 Integrated Voltage Measurement... 15:26:55 Voltage Offset Correction: v_off_ini = 893.216 uV, v_off_fin = 886.095 uV 15:26:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.148 uVs 15:26:55 Integrated Voltage Measurement... 15:27:04 Voltage Offset Correction: v_off_ini = 896.625 uV, v_off_fin = 888.291 uV 15:27:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.503 uVs 15:27:04 Integrated Voltage Measurement... 15:27:13 Voltage Offset Correction: v_off_ini = 907.414 uV, v_off_fin = 902.486 uV 15:27:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.444 uVs 15:27:13 Integrated Voltage Measurement... 15:27:22 Voltage Offset Correction: v_off_ini = 912.434 uV, v_off_fin = 897.228 uV 15:27:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.244 uVs 15:27:22 Integrated Voltage Measurement... 15:27:31 Voltage Offset Correction: v_off_ini = 881.215 uV, v_off_fin = 907.530 uV 15:27:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.278 uVs 15:27:31 Integrated Voltage Measurement... 15:27:40 Voltage Offset Correction: v_off_ini = 909.334 uV, v_off_fin = 902.866 uV 15:27:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.620 uVs 15:27:45 I1X Average and RMS of Measurements VT = -106.873 +- 12.050 uVs I1X = 21.375 +- 2.410 uTm 15:27:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:27:51 Integrated Voltage Measurement... 15:28:00 Voltage Offset Correction: v_off_ini = 884.345 uV, v_off_fin = 896.716 uV 15:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.391 uVs 15:28:00 Integrated Voltage Measurement... 15:28:09 Voltage Offset Correction: v_off_ini = 879.832 uV, v_off_fin = 902.516 uV 15:28:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.953 uVs 15:28:09 Integrated Voltage Measurement... 15:28:18 Voltage Offset Correction: v_off_ini = 900.907 uV, v_off_fin = 899.340 uV 15:28:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.089 uVs 15:28:18 Integrated Voltage Measurement... 15:28:27 Voltage Offset Correction: v_off_ini = 895.339 uV, v_off_fin = 910.844 uV 15:28:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.965 uVs 15:28:27 Integrated Voltage Measurement... 15:28:36 Voltage Offset Correction: v_off_ini = 898.908 uV, v_off_fin = 878.922 uV 15:28:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.806 uVs 15:28:36 Integrated Voltage Measurement... 15:28:45 Voltage Offset Correction: v_off_ini = 903.804 uV, v_off_fin = 910.212 uV 15:28:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.332 uVs 15:28:50 I1Y Average and RMS of Measurements VT = -189.923 +- 5.612 uVs I1Y = -37.985 +- 1.122 uTm 15:28:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:28:57 Integrated Voltage Measurement... 15:29:06 Voltage Offset Correction: v_off_ini = 901.062 uV, v_off_fin = 892.888 uV 15:29:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.096 uVs 15:29:06 Integrated Voltage Measurement... 15:29:15 Voltage Offset Correction: v_off_ini = 906.220 uV, v_off_fin = 875.200 uV 15:29:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.537 uVs 15:29:15 Integrated Voltage Measurement... 15:29:24 Voltage Offset Correction: v_off_ini = 887.224 uV, v_off_fin = 869.752 uV 15:29:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.794 uVs 15:29:24 Integrated Voltage Measurement... 15:29:33 Voltage Offset Correction: v_off_ini = 873.650 uV, v_off_fin = 885.580 uV 15:29:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.481 uVs 15:29:33 Integrated Voltage Measurement... 15:29:42 Voltage Offset Correction: v_off_ini = 893.432 uV, v_off_fin = 887.418 uV 15:29:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.415 uVs 15:29:42 Integrated Voltage Measurement... 15:29:51 Voltage Offset Correction: v_off_ini = 866.227 uV, v_off_fin = 876.949 uV 15:29:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.391 uVs 15:29:54 I2X Average and RMS of Measurements VT = -110.119 +- 4.496 uVs I2X = 10.131 +- 0.414 uTm^2 15:29:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:30:02 Integrated Voltage Measurement... 15:30:11 Voltage Offset Correction: v_off_ini = 855.514 uV, v_off_fin = 858.715 uV 15:30:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.329 uVs 15:30:11 Integrated Voltage Measurement... 15:30:20 Voltage Offset Correction: v_off_ini = 861.586 uV, v_off_fin = 858.305 uV 15:30:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.218 uVs 15:30:20 Integrated Voltage Measurement... 15:30:29 Voltage Offset Correction: v_off_ini = 854.027 uV, v_off_fin = 848.466 uV 15:30:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.832 uVs 15:30:29 Integrated Voltage Measurement... 15:30:38 Voltage Offset Correction: v_off_ini = 852.708 uV, v_off_fin = 869.549 uV 15:30:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.881 uVs 15:30:38 Integrated Voltage Measurement... 15:30:47 Voltage Offset Correction: v_off_ini = 859.318 uV, v_off_fin = 865.765 uV 15:30:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.156 uVs 15:30:47 Integrated Voltage Measurement... 15:30:56 Voltage Offset Correction: v_off_ini = 843.594 uV, v_off_fin = 845.775 uV 15:30:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.248 uVs 15:30:58 I2Y Average and RMS of Measurements VT = -243.277 +- 6.844 uVs I2Y = -22.382 +- 0.630 uTm^2 15:31:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:07 Integrated Voltage Measurement... 15:31:16 Voltage Offset Correction: v_off_ini = 863.830 uV, v_off_fin = 858.902 uV 15:31:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -104.614 uVs 15:31:16 Integrated Voltage Measurement... 15:31:25 Voltage Offset Correction: v_off_ini = 862.303 uV, v_off_fin = 845.760 uV 15:31:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.019 uVs 15:31:25 Integrated Voltage Measurement... 15:31:34 Voltage Offset Correction: v_off_ini = 839.065 uV, v_off_fin = 842.125 uV 15:31:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.515 uVs 15:31:34 Integrated Voltage Measurement... 15:31:43 Voltage Offset Correction: v_off_ini = 806.593 uV, v_off_fin = 828.258 uV 15:31:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.896 uVs 15:31:43 Integrated Voltage Measurement... 15:31:52 Voltage Offset Correction: v_off_ini = 834.563 uV, v_off_fin = 854.810 uV 15:31:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.457 uVs 15:31:52 Integrated Voltage Measurement... 15:32:01 Voltage Offset Correction: v_off_ini = 836.285 uV, v_off_fin = 846.532 uV 15:32:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.201 uVs 15:32:05 I1X Average and RMS of Measurements VT = -94.950 +- 3.073 uVs I1X = 18.990 +- 0.615 uTm 15:32:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:32:12 Integrated Voltage Measurement... 15:32:21 Voltage Offset Correction: v_off_ini = 862.585 uV, v_off_fin = 843.501 uV 15:32:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.648 uVs 15:32:21 Integrated Voltage Measurement... 15:32:30 Voltage Offset Correction: v_off_ini = 872.928 uV, v_off_fin = 881.324 uV 15:32:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.748 uVs 15:32:30 Integrated Voltage Measurement... 15:32:39 Voltage Offset Correction: v_off_ini = 881.026 uV, v_off_fin = 872.891 uV 15:32:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.149 uVs 15:32:39 Integrated Voltage Measurement... 15:32:48 Voltage Offset Correction: v_off_ini = 868.134 uV, v_off_fin = 873.218 uV 15:32:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.171 uVs 15:32:48 Integrated Voltage Measurement... 15:32:57 Voltage Offset Correction: v_off_ini = 868.824 uV, v_off_fin = 862.955 uV 15:32:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.468 uVs 15:32:57 Integrated Voltage Measurement... 15:33:06 Voltage Offset Correction: v_off_ini = 879.447 uV, v_off_fin = 895.733 uV 15:33:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.242 uVs 15:33:10 I1Y Average and RMS of Measurements VT = -184.238 +- 5.258 uVs I1Y = -36.848 +- 1.052 uTm 15:33:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:33:18 Integrated Voltage Measurement... 15:33:27 Voltage Offset Correction: v_off_ini = 889.953 uV, v_off_fin = 904.358 uV 15:33:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.362 uVs 15:33:27 Integrated Voltage Measurement... 15:33:36 Voltage Offset Correction: v_off_ini = 894.396 uV, v_off_fin = 905.509 uV 15:33:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.116 uVs 15:33:36 Integrated Voltage Measurement... 15:33:45 Voltage Offset Correction: v_off_ini = 905.027 uV, v_off_fin = 894.061 uV 15:33:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.316 uVs 15:33:45 Integrated Voltage Measurement... 15:33:54 Voltage Offset Correction: v_off_ini = 905.426 uV, v_off_fin = 908.678 uV 15:33:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.940 uVs 15:33:54 Integrated Voltage Measurement... 15:34:03 Voltage Offset Correction: v_off_ini = 890.320 uV, v_off_fin = 905.345 uV 15:34:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.447 uVs 15:34:03 Integrated Voltage Measurement... 15:34:12 Voltage Offset Correction: v_off_ini = 897.264 uV, v_off_fin = 896.901 uV 15:34:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.697 uVs 15:34:15 I2X Average and RMS of Measurements VT = -98.480 +- 5.144 uVs I2X = 9.060 +- 0.473 uTm^2 15:34:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:23 Integrated Voltage Measurement... 15:34:32 Voltage Offset Correction: v_off_ini = 902.826 uV, v_off_fin = 909.743 uV 15:34:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.713 uVs 15:34:32 Integrated Voltage Measurement... 15:34:41 Voltage Offset Correction: v_off_ini = 867.269 uV, v_off_fin = 873.728 uV 15:34:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.011 uVs 15:34:41 Integrated Voltage Measurement... 15:34:50 Voltage Offset Correction: v_off_ini = 886.248 uV, v_off_fin = 895.821 uV 15:34:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.042 uVs 15:34:50 Integrated Voltage Measurement... 15:34:59 Voltage Offset Correction: v_off_ini = 884.699 uV, v_off_fin = 879.139 uV 15:34:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.418 uVs 15:34:59 Integrated Voltage Measurement... 15:35:08 Voltage Offset Correction: v_off_ini = 879.665 uV, v_off_fin = 890.022 uV 15:35:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.687 uVs 15:35:08 Integrated Voltage Measurement... 15:35:17 Voltage Offset Correction: v_off_ini = 873.989 uV, v_off_fin = 897.029 uV 15:35:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.578 uVs 15:35:19 I2Y Average and RMS of Measurements VT = -241.741 +- 3.039 uVs I2Y = -22.240 +- 0.280 uTm^2 15:35:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:35:28 Integrated Voltage Measurement... 15:35:37 Voltage Offset Correction: v_off_ini = 856.874 uV, v_off_fin = 869.866 uV 15:35:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.445 uVs 15:35:37 Integrated Voltage Measurement... 15:35:46 Voltage Offset Correction: v_off_ini = 871.135 uV, v_off_fin = 880.898 uV 15:35:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.277 uVs 15:35:46 Integrated Voltage Measurement... 15:35:55 Voltage Offset Correction: v_off_ini = 871.153 uV, v_off_fin = 860.557 uV 15:35:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.191 uVs 15:35:55 Integrated Voltage Measurement... 15:36:04 Voltage Offset Correction: v_off_ini = 886.378 uV, v_off_fin = 881.696 uV 15:36:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.119 uVs 15:36:04 Integrated Voltage Measurement... 15:36:13 Voltage Offset Correction: v_off_ini = 871.560 uV, v_off_fin = 891.835 uV 15:36:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.413 uVs 15:36:13 Integrated Voltage Measurement... 15:36:22 Voltage Offset Correction: v_off_ini = 880.855 uV, v_off_fin = 907.095 uV 15:36:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.594 uVs 15:36:26 I1X Average and RMS of Measurements VT = -75.507 +- 7.477 uVs I1X = 15.101 +- 1.495 uTm 15:36:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:36:33 Integrated Voltage Measurement... 15:36:42 Voltage Offset Correction: v_off_ini = 906.858 uV, v_off_fin = 889.135 uV 15:36:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.879 uVs 15:36:42 Integrated Voltage Measurement... 15:36:51 Voltage Offset Correction: v_off_ini = 895.606 uV, v_off_fin = 884.270 uV 15:36:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.015 uVs 15:36:51 Integrated Voltage Measurement... 15:37:00 Voltage Offset Correction: v_off_ini = 888.954 uV, v_off_fin = 887.325 uV 15:37:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.829 uVs 15:37:00 Integrated Voltage Measurement... 15:37:09 Voltage Offset Correction: v_off_ini = 892.793 uV, v_off_fin = 903.977 uV 15:37:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.199 uVs 15:37:09 Integrated Voltage Measurement... 15:37:18 Voltage Offset Correction: v_off_ini = 908.569 uV, v_off_fin = 900.050 uV 15:37:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.226 uVs 15:37:18 Integrated Voltage Measurement... 15:37:27 Voltage Offset Correction: v_off_ini = 907.149 uV, v_off_fin = 905.627 uV 15:37:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.262 uVs 15:37:31 I1Y Average and RMS of Measurements VT = -187.068 +- 3.486 uVs I1Y = -37.414 +- 0.697 uTm 15:37:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:37:39 Integrated Voltage Measurement... 15:37:48 Voltage Offset Correction: v_off_ini = 917.756 uV, v_off_fin = 906.648 uV 15:37:48 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -113.810 uVs 15:37:48 Integrated Voltage Measurement... 15:37:57 Voltage Offset Correction: v_off_ini = 912.227 uV, v_off_fin = 910.927 uV 15:37:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.258 uVs 15:37:57 Integrated Voltage Measurement... 15:38:06 Voltage Offset Correction: v_off_ini = 892.739 uV, v_off_fin = 892.604 uV 15:38:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.189 uVs 15:38:06 Integrated Voltage Measurement... 15:38:15 Voltage Offset Correction: v_off_ini = 912.224 uV, v_off_fin = 925.415 uV 15:38:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.702 uVs 15:38:15 Integrated Voltage Measurement... 15:38:24 Voltage Offset Correction: v_off_ini = 903.188 uV, v_off_fin = 901.606 uV 15:38:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.369 uVs 15:38:24 Integrated Voltage Measurement... 15:38:33 Voltage Offset Correction: v_off_ini = 910.895 uV, v_off_fin = 917.405 uV 15:38:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.453 uVs 15:38:36 I2X Average and RMS of Measurements VT = -97.297 +- 10.478 uVs I2X = 8.951 +- 0.964 uTm^2 15:38:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:38:44 Integrated Voltage Measurement... 15:38:53 Voltage Offset Correction: v_off_ini = 898.272 uV, v_off_fin = 907.806 uV 15:38:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.579 uVs 15:38:53 Integrated Voltage Measurement... 15:39:02 Voltage Offset Correction: v_off_ini = 890.385 uV, v_off_fin = 900.928 uV 15:39:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.535 uVs 15:39:02 Integrated Voltage Measurement... 15:39:11 Voltage Offset Correction: v_off_ini = 895.989 uV, v_off_fin = 903.717 uV 15:39:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.172 uVs 15:39:11 Integrated Voltage Measurement... 15:39:20 Voltage Offset Correction: v_off_ini = 899.010 uV, v_off_fin = 898.699 uV 15:39:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.255 uVs 15:39:20 Integrated Voltage Measurement... 15:39:29 Voltage Offset Correction: v_off_ini = 879.544 uV, v_off_fin = 878.674 uV 15:39:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.738 uVs 15:39:29 Integrated Voltage Measurement... 15:39:38 Voltage Offset Correction: v_off_ini = 879.911 uV, v_off_fin = 867.831 uV 15:39:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.955 uVs 15:39:40 I2Y Average and RMS of Measurements VT = -247.206 +- 6.574 uVs I2Y = -22.743 +- 0.605 uTm^2 15:39:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:39:49 Integrated Voltage Measurement... 15:39:58 Voltage Offset Correction: v_off_ini = 870.322 uV, v_off_fin = 889.061 uV 15:39:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -72.354 uVs 15:39:58 Integrated Voltage Measurement... 15:40:07 Voltage Offset Correction: v_off_ini = 895.763 uV, v_off_fin = 899.125 uV 15:40:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.574 uVs 15:40:07 Integrated Voltage Measurement... 15:40:16 Voltage Offset Correction: v_off_ini = 895.370 uV, v_off_fin = 873.218 uV 15:40:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.147 uVs 15:40:16 Integrated Voltage Measurement... 15:40:25 Voltage Offset Correction: v_off_ini = 855.210 uV, v_off_fin = 857.604 uV 15:40:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.950 uVs 15:40:25 Integrated Voltage Measurement... 15:40:34 Voltage Offset Correction: v_off_ini = 867.224 uV, v_off_fin = 857.707 uV 15:40:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.662 uVs 15:40:34 Integrated Voltage Measurement... 15:40:43 Voltage Offset Correction: v_off_ini = 870.855 uV, v_off_fin = 870.154 uV 15:40:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.655 uVs 15:40:47 I1X Average and RMS of Measurements VT = -79.224 +- 7.522 uVs I1X = 15.845 +- 1.504 uTm 15:40:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:40:54 Integrated Voltage Measurement... 15:41:03 Voltage Offset Correction: v_off_ini = 866.968 uV, v_off_fin = 865.982 uV 15:41:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.395 uVs 15:41:03 Integrated Voltage Measurement... 15:41:12 Voltage Offset Correction: v_off_ini = 857.868 uV, v_off_fin = 877.786 uV 15:41:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.826 uVs 15:41:12 Integrated Voltage Measurement... 15:41:21 Voltage Offset Correction: v_off_ini = 852.935 uV, v_off_fin = 852.321 uV 15:41:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.618 uVs 15:41:21 Integrated Voltage Measurement... 15:41:30 Voltage Offset Correction: v_off_ini = 870.229 uV, v_off_fin = 890.485 uV 15:41:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.048 uVs 15:41:30 Integrated Voltage Measurement... 15:41:39 Voltage Offset Correction: v_off_ini = 880.765 uV, v_off_fin = 869.487 uV 15:41:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.167 uVs 15:41:39 Integrated Voltage Measurement... 15:41:48 Voltage Offset Correction: v_off_ini = 870.536 uV, v_off_fin = 880.139 uV 15:41:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.175 uVs 15:41:52 I1Y Average and RMS of Measurements VT = -185.872 +- 8.129 uVs I1Y = -37.174 +- 1.626 uTm 15:41:58 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:42:00 Integrated Voltage Measurement... 15:42:09 Voltage Offset Correction: v_off_ini = 865.469 uV, v_off_fin = 866.274 uV 15:42:09 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -85.623 uVs 15:42:09 Integrated Voltage Measurement... 15:42:18 Voltage Offset Correction: v_off_ini = 851.857 uV, v_off_fin = 851.757 uV 15:42:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.533 uVs 15:42:18 Integrated Voltage Measurement... 15:42:27 Voltage Offset Correction: v_off_ini = 843.167 uV, v_off_fin = 846.405 uV 15:42:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.472 uVs 15:42:27 Integrated Voltage Measurement... 15:42:36 Voltage Offset Correction: v_off_ini = 849.070 uV, v_off_fin = 867.828 uV 15:42:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.832 uVs 15:42:36 Integrated Voltage Measurement... 15:42:45 Voltage Offset Correction: v_off_ini = 852.515 uV, v_off_fin = 852.740 uV 15:42:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.414 uVs 15:42:45 Integrated Voltage Measurement... 15:42:54 Voltage Offset Correction: v_off_ini = 861.899 uV, v_off_fin = 840.750 uV 15:42:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.525 uVs 15:42:57 I2X Average and RMS of Measurements VT = -88.567 +- 13.732 uVs I2X = 8.148 +- 1.263 uTm^2 15:43:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:43:04 Integrated Voltage Measurement... 15:43:13 Voltage Offset Correction: v_off_ini = 834.616 uV, v_off_fin = 821.291 uV 15:43:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.126 uVs 15:43:14 Integrated Voltage Measurement... 15:43:22 Voltage Offset Correction: v_off_ini = 826.187 uV, v_off_fin = 818.635 uV 15:43:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.054 uVs 15:43:23 Integrated Voltage Measurement... 15:43:32 Voltage Offset Correction: v_off_ini = 824.924 uV, v_off_fin = 835.612 uV 15:43:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.327 uVs 15:43:32 Integrated Voltage Measurement... 15:43:41 Voltage Offset Correction: v_off_ini = 828.113 uV, v_off_fin = 842.468 uV 15:43:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.805 uVs 15:43:41 Integrated Voltage Measurement... 15:43:50 Voltage Offset Correction: v_off_ini = 839.567 uV, v_off_fin = 840.666 uV 15:43:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.299 uVs 15:43:50 Integrated Voltage Measurement... 15:43:59 Voltage Offset Correction: v_off_ini = 831.713 uV, v_off_fin = 847.133 uV 15:43:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.274 uVs 15:44:01 I2Y Average and RMS of Measurements VT = -236.648 +- 1.804 uVs I2Y = -21.772 +- 0.166 uTm^2 15:44:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:44:13 Integrated Voltage Measurement... 15:44:22 Voltage Offset Correction: v_off_ini = 844.112 uV, v_off_fin = 840.117 uV 15:44:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -99.144 uVs 15:44:22 Integrated Voltage Measurement... 15:44:31 Voltage Offset Correction: v_off_ini = 832.050 uV, v_off_fin = 824.369 uV 15:44:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.759 uVs 15:44:31 Integrated Voltage Measurement... 15:44:40 Voltage Offset Correction: v_off_ini = 822.772 uV, v_off_fin = 837.306 uV 15:44:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.059 uVs 15:44:40 Integrated Voltage Measurement... 15:44:49 Voltage Offset Correction: v_off_ini = 842.950 uV, v_off_fin = 833.393 uV 15:44:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.464 uVs 15:44:49 Integrated Voltage Measurement... 15:44:58 Voltage Offset Correction: v_off_ini = 840.104 uV, v_off_fin = 837.462 uV 15:44:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.245 uVs 15:44:58 Integrated Voltage Measurement... 15:45:07 Voltage Offset Correction: v_off_ini = 822.391 uV, v_off_fin = 810.130 uV 15:45:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.520 uVs 15:45:11 I1X Average and RMS of Measurements VT = -94.032 +- 7.184 uVs I1X = 18.807 +- 1.437 uTm 15:45:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:45:18 Integrated Voltage Measurement... 15:45:27 Voltage Offset Correction: v_off_ini = 841.983 uV, v_off_fin = 818.667 uV 15:45:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.532 uVs 15:45:27 Integrated Voltage Measurement... 15:45:36 Voltage Offset Correction: v_off_ini = 853.260 uV, v_off_fin = 851.849 uV 15:45:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.968 uVs 15:45:36 Integrated Voltage Measurement... 15:45:45 Voltage Offset Correction: v_off_ini = 853.747 uV, v_off_fin = 807.099 uV 15:45:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.793 uVs 15:45:45 Integrated Voltage Measurement... 15:45:54 Voltage Offset Correction: v_off_ini = 861.285 uV, v_off_fin = 849.850 uV 15:45:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.363 uVs 15:45:54 Integrated Voltage Measurement... 15:46:03 Voltage Offset Correction: v_off_ini = 824.872 uV, v_off_fin = 824.057 uV 15:46:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.914 uVs 15:46:03 Integrated Voltage Measurement... 15:46:12 Voltage Offset Correction: v_off_ini = 856.385 uV, v_off_fin = 849.697 uV 15:46:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.137 uVs 15:46:16 I1Y Average and RMS of Measurements VT = -194.618 +- 9.943 uVs I1Y = -38.924 +- 1.989 uTm 15:46:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:46:22 Integrated Voltage Measurement... 15:46:31 Voltage Offset Correction: v_off_ini = 811.850 uV, v_off_fin = 828.806 uV 15:46:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -111.071 uVs 15:46:31 Integrated Voltage Measurement... 15:46:40 Voltage Offset Correction: v_off_ini = 826.974 uV, v_off_fin = 838.173 uV 15:46:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.835 uVs 15:46:40 Integrated Voltage Measurement... 15:46:49 Voltage Offset Correction: v_off_ini = 840.390 uV, v_off_fin = 831.011 uV 15:46:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.361 uVs 15:46:49 Integrated Voltage Measurement... 15:46:58 Voltage Offset Correction: v_off_ini = 835.663 uV, v_off_fin = 839.924 uV 15:46:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.433 uVs 15:46:58 Integrated Voltage Measurement... 15:47:07 Voltage Offset Correction: v_off_ini = 825.371 uV, v_off_fin = 828.606 uV 15:47:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.807 uVs 15:47:07 Integrated Voltage Measurement... 15:47:16 Voltage Offset Correction: v_off_ini = 805.027 uV, v_off_fin = 803.281 uV 15:47:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.448 uVs 15:47:18 I2X Average and RMS of Measurements VT = -108.826 +- 6.006 uVs I2X = 10.012 +- 0.552 uTm^2 15:47:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:47:23 Integrated Voltage Measurement... 15:47:32 Voltage Offset Correction: v_off_ini = 812.626 uV, v_off_fin = 804.228 uV 15:47:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.794 uVs 15:47:32 Integrated Voltage Measurement... 15:47:41 Voltage Offset Correction: v_off_ini = 812.979 uV, v_off_fin = 815.343 uV 15:47:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.923 uVs 15:47:41 Integrated Voltage Measurement... 15:47:50 Voltage Offset Correction: v_off_ini = 806.413 uV, v_off_fin = 795.404 uV 15:47:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.464 uVs 15:47:50 Integrated Voltage Measurement... 15:47:59 Voltage Offset Correction: v_off_ini = 801.917 uV, v_off_fin = 811.347 uV 15:47:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.766 uVs 15:48:00 Integrated Voltage Measurement... 15:48:09 Voltage Offset Correction: v_off_ini = 791.452 uV, v_off_fin = 794.312 uV 15:48:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.465 uVs 15:48:09 Integrated Voltage Measurement... 15:48:18 Voltage Offset Correction: v_off_ini = 800.994 uV, v_off_fin = 811.139 uV 15:48:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.299 uVs 15:48:20 I2Y Average and RMS of Measurements VT = -251.952 +- 4.885 uVs I2Y = -23.180 +- 0.449 uTm^2 15:48:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:48:28 Integrated Voltage Measurement... 15:48:37 Voltage Offset Correction: v_off_ini = 800.428 uV, v_off_fin = 809.747 uV 15:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.482 uVs 15:48:37 Integrated Voltage Measurement... 15:48:46 Voltage Offset Correction: v_off_ini = 811.013 uV, v_off_fin = 810.101 uV 15:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.872 uVs 15:48:46 Integrated Voltage Measurement... 15:48:55 Voltage Offset Correction: v_off_ini = 797.119 uV, v_off_fin = 812.987 uV 15:48:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.402 uVs 15:48:55 Integrated Voltage Measurement... 15:49:04 Voltage Offset Correction: v_off_ini = 832.423 uV, v_off_fin = 829.130 uV 15:49:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.136 uVs 15:49:04 Integrated Voltage Measurement... 15:49:13 Voltage Offset Correction: v_off_ini = 832.696 uV, v_off_fin = 826.105 uV 15:49:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.503 uVs 15:49:13 Integrated Voltage Measurement... 15:49:22 Voltage Offset Correction: v_off_ini = 804.713 uV, v_off_fin = 822.129 uV 15:49:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 75.065 uVs 15:49:27 I1X Average and RMS of Measurements VT = -83.910 +- 2.640 uVs I1X = 16.782 +- 0.528 uTm 15:49:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:49:33 Integrated Voltage Measurement... 15:49:42 Voltage Offset Correction: v_off_ini = 821.170 uV, v_off_fin = 815.608 uV 15:49:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.405 uVs 15:49:42 Integrated Voltage Measurement... 15:49:51 Voltage Offset Correction: v_off_ini = 808.197 uV, v_off_fin = 839.102 uV 15:49:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.149 uVs 15:49:51 Integrated Voltage Measurement... 15:50:00 Voltage Offset Correction: v_off_ini = 821.845 uV, v_off_fin = 826.341 uV 15:50:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.235 uVs 15:50:00 Integrated Voltage Measurement... 15:50:09 Voltage Offset Correction: v_off_ini = 821.077 uV, v_off_fin = 827.645 uV 15:50:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.794 uVs 15:50:09 Integrated Voltage Measurement... 15:50:18 Voltage Offset Correction: v_off_ini = 826.304 uV, v_off_fin = 814.946 uV 15:50:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.744 uVs 15:50:18 Integrated Voltage Measurement... 15:50:27 Voltage Offset Correction: v_off_ini = 817.141 uV, v_off_fin = 829.121 uV 15:50:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.851 uVs 15:50:32 I1Y Average and RMS of Measurements VT = -196.863 +- 5.358 uVs I1Y = -39.373 +- 1.072 uTm 15:50:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:50:37 Integrated Voltage Measurement... 15:50:46 Voltage Offset Correction: v_off_ini = 800.281 uV, v_off_fin = 788.594 uV 15:50:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.029 uVs 15:50:46 Integrated Voltage Measurement... 15:50:55 Voltage Offset Correction: v_off_ini = 815.462 uV, v_off_fin = 823.054 uV 15:50:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.979 uVs 15:50:55 Integrated Voltage Measurement... 15:51:04 Voltage Offset Correction: v_off_ini = 794.931 uV, v_off_fin = 797.503 uV 15:51:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.581 uVs 15:51:04 Integrated Voltage Measurement... 15:51:13 Voltage Offset Correction: v_off_ini = 804.045 uV, v_off_fin = 809.216 uV 15:51:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.563 uVs 15:51:13 Integrated Voltage Measurement... 15:51:22 Voltage Offset Correction: v_off_ini = 805.385 uV, v_off_fin = 801.280 uV 15:51:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.281 uVs 15:51:22 Integrated Voltage Measurement... 15:51:31 Voltage Offset Correction: v_off_ini = 804.717 uV, v_off_fin = 830.468 uV 15:51:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.165 uVs 15:51:33 I2X Average and RMS of Measurements VT = -109.933 +- 1.893 uVs I2X = 10.114 +- 0.174 uTm^2 15:51:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:51:38 Integrated Voltage Measurement... 15:51:47 Voltage Offset Correction: v_off_ini = 812.875 uV, v_off_fin = 814.110 uV 15:51:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.391 uVs 15:51:47 Integrated Voltage Measurement... 15:51:56 Voltage Offset Correction: v_off_ini = 803.093 uV, v_off_fin = 808.550 uV 15:51:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.801 uVs 15:51:57 Integrated Voltage Measurement... 15:52:06 Voltage Offset Correction: v_off_ini = 821.780 uV, v_off_fin = 830.415 uV 15:52:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.912 uVs 15:52:06 Integrated Voltage Measurement... 15:52:15 Voltage Offset Correction: v_off_ini = 825.004 uV, v_off_fin = 827.121 uV 15:52:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.784 uVs 15:52:15 Integrated Voltage Measurement... 15:52:24 Voltage Offset Correction: v_off_ini = 806.224 uV, v_off_fin = 811.474 uV 15:52:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.866 uVs 15:52:24 Integrated Voltage Measurement... 15:52:33 Voltage Offset Correction: v_off_ini = 821.028 uV, v_off_fin = 822.775 uV 15:52:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.106 uVs 15:52:35 I2Y Average and RMS of Measurements VT = -247.643 +- 8.612 uVs I2Y = -22.783 +- 0.792 uTm^2 15:52:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:43 Integrated Voltage Measurement... 15:52:52 Voltage Offset Correction: v_off_ini = 827.883 uV, v_off_fin = 809.013 uV 15:52:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.346 uVs 15:52:52 Integrated Voltage Measurement... 15:53:01 Voltage Offset Correction: v_off_ini = 818.545 uV, v_off_fin = 814.257 uV 15:53:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.825 uVs 15:53:01 Integrated Voltage Measurement... 15:53:10 Voltage Offset Correction: v_off_ini = 831.458 uV, v_off_fin = 827.300 uV 15:53:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.625 uVs 15:53:11 Integrated Voltage Measurement... 15:53:19 Voltage Offset Correction: v_off_ini = 833.810 uV, v_off_fin = 836.493 uV 15:53:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.731 uVs 15:53:20 Integrated Voltage Measurement... 15:53:28 Voltage Offset Correction: v_off_ini = 828.063 uV, v_off_fin = 824.174 uV 15:53:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.101 uVs 15:53:29 Integrated Voltage Measurement... 15:53:38 Voltage Offset Correction: v_off_ini = 829.358 uV, v_off_fin = 837.019 uV 15:53:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.100 uVs 15:53:42 I1X Average and RMS of Measurements VT = -86.455 +- 9.224 uVs I1X = 17.291 +- 1.845 uTm 15:53:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:49 Integrated Voltage Measurement... 15:53:57 Voltage Offset Correction: v_off_ini = 824.144 uV, v_off_fin = 818.433 uV 15:53:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -172.994 uVs 15:53:58 Integrated Voltage Measurement... 15:54:06 Voltage Offset Correction: v_off_ini = 846.774 uV, v_off_fin = 851.880 uV 15:54:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 178.829 uVs 15:54:07 Integrated Voltage Measurement... 15:54:15 Voltage Offset Correction: v_off_ini = 844.530 uV, v_off_fin = 834.758 uV 15:54:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.901 uVs 15:54:16 Integrated Voltage Measurement... 15:54:24 Voltage Offset Correction: v_off_ini = 837.014 uV, v_off_fin = 841.618 uV 15:54:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.311 uVs 15:54:25 Integrated Voltage Measurement... 15:54:33 Voltage Offset Correction: v_off_ini = 825.213 uV, v_off_fin = 823.789 uV 15:54:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.041 uVs 15:54:34 Integrated Voltage Measurement... 15:54:42 Voltage Offset Correction: v_off_ini = 832.602 uV, v_off_fin = 858.556 uV 15:54:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.365 uVs 15:54:47 I1Y Average and RMS of Measurements VT = -186.407 +- 7.528 uVs I1Y = -37.279 +- 1.504 uTm 15:54:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:52 Integrated Voltage Measurement... 15:55:01 Voltage Offset Correction: v_off_ini = 839.901 uV, v_off_fin = 822.347 uV 15:55:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.999 uVs 15:55:01 Integrated Voltage Measurement... 15:55:10 Voltage Offset Correction: v_off_ini = 832.628 uV, v_off_fin = 838.636 uV 15:55:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.314 uVs 15:55:10 Integrated Voltage Measurement... 15:55:19 Voltage Offset Correction: v_off_ini = 823.207 uV, v_off_fin = 824.784 uV 15:55:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.632 uVs 15:55:19 Integrated Voltage Measurement... 15:55:28 Voltage Offset Correction: v_off_ini = 853.021 uV, v_off_fin = 840.146 uV 15:55:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.658 uVs 15:55:28 Integrated Voltage Measurement... 15:55:37 Voltage Offset Correction: v_off_ini = 826.813 uV, v_off_fin = 813.492 uV 15:55:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.258 uVs 15:55:37 Integrated Voltage Measurement... 15:55:46 Voltage Offset Correction: v_off_ini = 817.308 uV, v_off_fin = 823.363 uV 15:55:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.318 uVs 15:55:48 I2X Average and RMS of Measurements VT = -111.030 +- 2.540 uVs I2X = 10.215 +- 0.234 uTm^2 15:55:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:55:54 Integrated Voltage Measurement... 15:56:03 Voltage Offset Correction: v_off_ini = 825.344 uV, v_off_fin = 822.383 uV 15:56:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.557 uVs 15:56:03 Integrated Voltage Measurement... 15:56:12 Voltage Offset Correction: v_off_ini = 815.756 uV, v_off_fin = 826.520 uV 15:56:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.761 uVs 15:56:12 Integrated Voltage Measurement... 15:56:21 Voltage Offset Correction: v_off_ini = 843.081 uV, v_off_fin = 824.654 uV 15:56:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.907 uVs 15:56:21 Integrated Voltage Measurement... 15:56:30 Voltage Offset Correction: v_off_ini = 825.161 uV, v_off_fin = 806.380 uV 15:56:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.085 uVs 15:56:30 Integrated Voltage Measurement... 15:56:39 Voltage Offset Correction: v_off_ini = 826.160 uV, v_off_fin = 813.238 uV 15:56:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.757 uVs 15:56:39 Integrated Voltage Measurement... 15:56:48 Voltage Offset Correction: v_off_ini = 846.201 uV, v_off_fin = 837.211 uV 15:56:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.683 uVs 15:56:50 I2Y Average and RMS of Measurements VT = -246.125 +- 7.113 uVs I2Y = -22.643 +- 0.654 uTm^2 15:56:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:56:59 Integrated Voltage Measurement... 15:57:08 Voltage Offset Correction: v_off_ini = 838.206 uV, v_off_fin = 834.812 uV 15:57:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -54.233 uVs 15:57:08 Integrated Voltage Measurement... 15:57:17 Voltage Offset Correction: v_off_ini = 835.752 uV, v_off_fin = 840.594 uV 15:57:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.217 uVs 15:57:17 Integrated Voltage Measurement... 15:57:26 Voltage Offset Correction: v_off_ini = 859.342 uV, v_off_fin = 860.221 uV 15:57:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.307 uVs 15:57:26 Integrated Voltage Measurement... 15:57:35 Voltage Offset Correction: v_off_ini = 842.366 uV, v_off_fin = 851.944 uV 15:57:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.777 uVs 15:57:35 Integrated Voltage Measurement... 15:57:44 Voltage Offset Correction: v_off_ini = 815.745 uV, v_off_fin = 821.096 uV 15:57:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.646 uVs 15:57:44 Integrated Voltage Measurement... 15:57:53 Voltage Offset Correction: v_off_ini = 806.942 uV, v_off_fin = 824.543 uV 15:57:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.993 uVs 15:57:57 I1X Average and RMS of Measurements VT = -78.362 +- 10.351 uVs I1X = 15.673 +- 2.070 uTm 15:57:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:58:04 Integrated Voltage Measurement... 15:58:13 Voltage Offset Correction: v_off_ini = 803.177 uV, v_off_fin = 786.310 uV 15:58:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -200.648 uVs 15:58:13 Integrated Voltage Measurement... 15:58:22 Voltage Offset Correction: v_off_ini = 796.269 uV, v_off_fin = 806.670 uV 15:58:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 170.532 uVs 15:58:22 Integrated Voltage Measurement... 15:58:31 Voltage Offset Correction: v_off_ini = 799.424 uV, v_off_fin = 788.827 uV 15:58:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.648 uVs 15:58:31 Integrated Voltage Measurement... 15:58:40 Voltage Offset Correction: v_off_ini = 809.928 uV, v_off_fin = 814.112 uV 15:58:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.165 uVs 15:58:40 Integrated Voltage Measurement... 15:58:49 Voltage Offset Correction: v_off_ini = 827.339 uV, v_off_fin = 786.825 uV 15:58:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.654 uVs 15:58:49 Integrated Voltage Measurement... 15:58:58 Voltage Offset Correction: v_off_ini = 825.013 uV, v_off_fin = 819.240 uV 15:58:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.678 uVs 15:59:02 I1Y Average and RMS of Measurements VT = -183.388 +- 2.328 uVs I1Y = -36.676 +- 0.466 uTm 15:59:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:59:07 Integrated Voltage Measurement... 15:59:16 Voltage Offset Correction: v_off_ini = 818.592 uV, v_off_fin = 788.815 uV 15:59:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.326 uVs 15:59:16 Integrated Voltage Measurement... 15:59:25 Voltage Offset Correction: v_off_ini = 805.274 uV, v_off_fin = 802.213 uV 15:59:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.600 uVs 15:59:25 Integrated Voltage Measurement... 15:59:34 Voltage Offset Correction: v_off_ini = 795.442 uV, v_off_fin = 789.417 uV 15:59:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.554 uVs 15:59:34 Integrated Voltage Measurement... 15:59:43 Voltage Offset Correction: v_off_ini = 787.950 uV, v_off_fin = 788.592 uV 15:59:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.748 uVs 15:59:43 Integrated Voltage Measurement... 15:59:52 Voltage Offset Correction: v_off_ini = 806.811 uV, v_off_fin = 799.345 uV 15:59:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.362 uVs 15:59:52 Integrated Voltage Measurement... 16:00:01 Voltage Offset Correction: v_off_ini = 802.850 uV, v_off_fin = 800.013 uV 16:00:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.607 uVs 16:00:04 I2X Average and RMS of Measurements VT = -113.366 +- 9.629 uVs I2X = 10.430 +- 0.886 uTm^2 16:00:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:00:09 Integrated Voltage Measurement... 16:00:18 Voltage Offset Correction: v_off_ini = 784.712 uV, v_off_fin = 782.663 uV 16:00:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.131 uVs 16:00:18 Integrated Voltage Measurement... 16:00:27 Voltage Offset Correction: v_off_ini = 771.010 uV, v_off_fin = 784.070 uV 16:00:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.600 uVs 16:00:27 Integrated Voltage Measurement... 16:00:36 Voltage Offset Correction: v_off_ini = 795.812 uV, v_off_fin = 788.969 uV 16:00:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.295 uVs 16:00:36 Integrated Voltage Measurement... 16:00:45 Voltage Offset Correction: v_off_ini = 769.747 uV, v_off_fin = 765.203 uV 16:00:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.582 uVs 16:00:45 Integrated Voltage Measurement... 16:00:54 Voltage Offset Correction: v_off_ini = 769.365 uV, v_off_fin = 780.109 uV 16:00:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.440 uVs 16:00:54 Integrated Voltage Measurement... 16:01:03 Voltage Offset Correction: v_off_ini = 776.188 uV, v_off_fin = 773.503 uV 16:01:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.469 uVs 16:01:05 I2Y Average and RMS of Measurements VT = -233.920 +- 5.709 uVs I2Y = -21.521 +- 0.525 uTm^2 16:01:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:01:14 Integrated Voltage Measurement... 16:01:23 Voltage Offset Correction: v_off_ini = 799.401 uV, v_off_fin = 795.819 uV 16:01:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.797 uVs 16:01:23 Integrated Voltage Measurement... 16:01:32 Voltage Offset Correction: v_off_ini = 800.176 uV, v_off_fin = 786.782 uV 16:01:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.147 uVs 16:01:32 Integrated Voltage Measurement... 16:01:41 Voltage Offset Correction: v_off_ini = 776.867 uV, v_off_fin = 783.340 uV 16:01:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.878 uVs 16:01:41 Integrated Voltage Measurement... 16:01:50 Voltage Offset Correction: v_off_ini = 791.489 uV, v_off_fin = 753.218 uV 16:01:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.894 uVs 16:01:50 Integrated Voltage Measurement... 16:01:59 Voltage Offset Correction: v_off_ini = 752.979 uV, v_off_fin = 748.297 uV 16:01:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.425 uVs 16:01:59 Integrated Voltage Measurement... 16:02:08 Voltage Offset Correction: v_off_ini = 749.708 uV, v_off_fin = 752.098 uV 16:02:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.803 uVs 16:02:12 I1X Average and RMS of Measurements VT = -72.991 +- 8.416 uVs I1X = 14.598 +- 1.684 uTm 16:02:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:02:19 Integrated Voltage Measurement... 16:02:28 Voltage Offset Correction: v_off_ini = 760.726 uV, v_off_fin = 750.422 uV 16:02:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -170.958 uVs 16:02:28 Integrated Voltage Measurement... 16:02:37 Voltage Offset Correction: v_off_ini = 762.556 uV, v_off_fin = 772.778 uV 16:02:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.471 uVs 16:02:37 Integrated Voltage Measurement... 16:02:46 Voltage Offset Correction: v_off_ini = 752.492 uV, v_off_fin = 742.862 uV 16:02:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.863 uVs 16:02:46 Integrated Voltage Measurement... 16:02:55 Voltage Offset Correction: v_off_ini = 753.703 uV, v_off_fin = 748.240 uV 16:02:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.632 uVs 16:02:55 Integrated Voltage Measurement... 16:03:04 Voltage Offset Correction: v_off_ini = 748.487 uV, v_off_fin = 740.144 uV 16:03:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.161 uVs 16:03:04 Integrated Voltage Measurement... 16:03:13 Voltage Offset Correction: v_off_ini = 739.127 uV, v_off_fin = 760.628 uV 16:03:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.099 uVs 16:03:17 I1Y Average and RMS of Measurements VT = -172.864 +- 5.747 uVs I1Y = -34.572 +- 1.150 uTm 16:03:19 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:03:22 Integrated Voltage Measurement... 16:03:31 Voltage Offset Correction: v_off_ini = 733.956 uV, v_off_fin = 733.926 uV 16:03:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.915 uVs 16:03:31 Integrated Voltage Measurement... 16:03:40 Voltage Offset Correction: v_off_ini = 748.983 uV, v_off_fin = 745.313 uV 16:03:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 65.202 uVs 16:03:40 Integrated Voltage Measurement... 16:03:49 Voltage Offset Correction: v_off_ini = 746.901 uV, v_off_fin = 744.914 uV 16:03:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.516 uVs 16:03:49 Integrated Voltage Measurement... 16:03:58 Voltage Offset Correction: v_off_ini = 717.688 uV, v_off_fin = 733.195 uV 16:03:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.869 uVs 16:03:58 Integrated Voltage Measurement... 16:04:07 Voltage Offset Correction: v_off_ini = 731.209 uV, v_off_fin = 726.265 uV 16:04:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.295 uVs 16:04:07 Integrated Voltage Measurement... 16:04:16 Voltage Offset Correction: v_off_ini = 733.851 uV, v_off_fin = 739.984 uV 16:04:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.655 uVs 16:04:19 I2X Average and RMS of Measurements VT = -83.242 +- 2.270 uVs I2X = 7.659 +- 0.209 uTm^2 16:04:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:04:24 Integrated Voltage Measurement... 16:04:33 Voltage Offset Correction: v_off_ini = 743.122 uV, v_off_fin = 754.917 uV 16:04:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.361 uVs 16:04:33 Integrated Voltage Measurement... 16:04:42 Voltage Offset Correction: v_off_ini = 745.338 uV, v_off_fin = 747.118 uV 16:04:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.233 uVs 16:04:42 Integrated Voltage Measurement... 16:04:51 Voltage Offset Correction: v_off_ini = 738.501 uV, v_off_fin = 764.182 uV 16:04:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.039 uVs 16:04:51 Integrated Voltage Measurement... 16:05:00 Voltage Offset Correction: v_off_ini = 751.005 uV, v_off_fin = 762.437 uV 16:05:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.881 uVs 16:05:00 Integrated Voltage Measurement... 16:05:09 Voltage Offset Correction: v_off_ini = 762.686 uV, v_off_fin = 747.426 uV 16:05:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.158 uVs 16:05:09 Integrated Voltage Measurement... 16:05:18 Voltage Offset Correction: v_off_ini = 741.813 uV, v_off_fin = 761.912 uV 16:05:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.699 uVs 16:05:20 I2Y Average and RMS of Measurements VT = -229.062 +- 5.263 uVs I2Y = -21.074 +- 0.484 uTm^2 16:05:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:05:41 Integrated Voltage Measurement... 16:05:50 Voltage Offset Correction: v_off_ini = 784.211 uV, v_off_fin = 793.742 uV 16:05:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -108.584 uVs 16:05:50 Integrated Voltage Measurement... 16:05:59 Voltage Offset Correction: v_off_ini = 767.760 uV, v_off_fin = 765.187 uV 16:05:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.300 uVs 16:05:59 Integrated Voltage Measurement... 16:06:08 Voltage Offset Correction: v_off_ini = 763.405 uV, v_off_fin = 755.386 uV 16:06:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.780 uVs 16:06:08 Integrated Voltage Measurement... 16:06:17 Voltage Offset Correction: v_off_ini = 761.697 uV, v_off_fin = 746.465 uV 16:06:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.275 uVs 16:06:17 Integrated Voltage Measurement... 16:06:26 Voltage Offset Correction: v_off_ini = 764.895 uV, v_off_fin = 748.756 uV 16:06:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.065 uVs 16:06:26 Integrated Voltage Measurement... 16:06:35 Voltage Offset Correction: v_off_ini = 738.591 uV, v_off_fin = 746.343 uV 16:06:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 137.030 uVs 16:06:39 I1X Average and RMS of Measurements VT = -102.172 +- 4.073 uVs I1X = 20.436 +- 0.815 uTm 16:06:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:06:46 Integrated Voltage Measurement... 16:06:55 Voltage Offset Correction: v_off_ini = 765.871 uV, v_off_fin = 762.268 uV 16:06:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.763 uVs 16:06:55 Integrated Voltage Measurement... 16:07:04 Voltage Offset Correction: v_off_ini = 768.515 uV, v_off_fin = 783.340 uV 16:07:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.794 uVs 16:07:04 Integrated Voltage Measurement... 16:07:13 Voltage Offset Correction: v_off_ini = 764.027 uV, v_off_fin = 766.142 uV 16:07:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.530 uVs 16:07:13 Integrated Voltage Measurement... 16:07:22 Voltage Offset Correction: v_off_ini = 773.018 uV, v_off_fin = 773.283 uV 16:07:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.576 uVs 16:07:22 Integrated Voltage Measurement... 16:07:31 Voltage Offset Correction: v_off_ini = 787.031 uV, v_off_fin = 769.931 uV 16:07:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.939 uVs 16:07:31 Integrated Voltage Measurement... 16:07:40 Voltage Offset Correction: v_off_ini = 784.502 uV, v_off_fin = 800.195 uV 16:07:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.833 uVs 16:07:44 I1Y Average and RMS of Measurements VT = -186.406 +- 4.153 uVs I1Y = -37.281 +- 0.831 uTm 16:07:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:07:52 Integrated Voltage Measurement... 16:08:01 Voltage Offset Correction: v_off_ini = 747.959 uV, v_off_fin = 757.884 uV 16:08:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.593 uVs 16:08:01 Integrated Voltage Measurement... 16:08:10 Voltage Offset Correction: v_off_ini = 755.196 uV, v_off_fin = 773.463 uV 16:08:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.291 uVs 16:08:10 Integrated Voltage Measurement... 16:08:19 Voltage Offset Correction: v_off_ini = 774.606 uV, v_off_fin = 776.928 uV 16:08:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.741 uVs 16:08:19 Integrated Voltage Measurement... 16:08:28 Voltage Offset Correction: v_off_ini = 765.753 uV, v_off_fin = 769.325 uV 16:08:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.083 uVs 16:08:28 Integrated Voltage Measurement... 16:08:37 Voltage Offset Correction: v_off_ini = 759.142 uV, v_off_fin = 755.713 uV 16:08:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.733 uVs 16:08:37 Integrated Voltage Measurement... 16:08:46 Voltage Offset Correction: v_off_ini = 743.632 uV, v_off_fin = 770.686 uV 16:08:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.075 uVs 16:08:48 I2X Average and RMS of Measurements VT = -118.253 +- 1.651 uVs I2X = 10.879 +- 0.152 uTm^2 16:08:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:08:56 Integrated Voltage Measurement... 16:09:05 Voltage Offset Correction: v_off_ini = 771.457 uV, v_off_fin = 756.305 uV 16:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.106 uVs 16:09:05 Integrated Voltage Measurement... 16:09:14 Voltage Offset Correction: v_off_ini = 763.046 uV, v_off_fin = 763.595 uV 16:09:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.636 uVs 16:09:14 Integrated Voltage Measurement... 16:09:23 Voltage Offset Correction: v_off_ini = 755.202 uV, v_off_fin = 750.509 uV 16:09:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.325 uVs 16:09:23 Integrated Voltage Measurement... 16:09:32 Voltage Offset Correction: v_off_ini = 770.782 uV, v_off_fin = 767.400 uV 16:09:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.756 uVs 16:09:32 Integrated Voltage Measurement... 16:09:41 Voltage Offset Correction: v_off_ini = 781.607 uV, v_off_fin = 758.441 uV 16:09:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.547 uVs 16:09:41 Integrated Voltage Measurement... 16:09:50 Voltage Offset Correction: v_off_ini = 770.998 uV, v_off_fin = 766.220 uV 16:09:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.379 uVs 16:09:53 I2Y Average and RMS of Measurements VT = -235.625 +- 6.770 uVs I2Y = -21.677 +- 0.623 uTm^2 16:09:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:10:02 Integrated Voltage Measurement... 16:10:11 Voltage Offset Correction: v_off_ini = 754.364 uV, v_off_fin = 745.724 uV 16:10:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -109.848 uVs 16:10:11 Integrated Voltage Measurement... 16:10:20 Voltage Offset Correction: v_off_ini = 753.643 uV, v_off_fin = 760.092 uV 16:10:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.194 uVs 16:10:20 Integrated Voltage Measurement... 16:10:29 Voltage Offset Correction: v_off_ini = 748.662 uV, v_off_fin = 756.101 uV 16:10:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.620 uVs 16:10:29 Integrated Voltage Measurement... 16:10:38 Voltage Offset Correction: v_off_ini = 779.147 uV, v_off_fin = 774.814 uV 16:10:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.379 uVs 16:10:38 Integrated Voltage Measurement... 16:10:47 Voltage Offset Correction: v_off_ini = 766.652 uV, v_off_fin = 754.987 uV 16:10:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.693 uVs 16:10:47 Integrated Voltage Measurement... 16:10:56 Voltage Offset Correction: v_off_ini = 761.004 uV, v_off_fin = 759.403 uV 16:10:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.181 uVs 16:11:00 I1X Average and RMS of Measurements VT = -92.819 +- 4.957 uVs I1X = 18.564 +- 0.992 uTm 16:11:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:11:07 Integrated Voltage Measurement... 16:11:16 Voltage Offset Correction: v_off_ini = 765.719 uV, v_off_fin = 744.286 uV 16:11:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.867 uVs 16:11:16 Integrated Voltage Measurement... 16:11:25 Voltage Offset Correction: v_off_ini = 760.929 uV, v_off_fin = 759.387 uV 16:11:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.374 uVs 16:11:25 Integrated Voltage Measurement... 16:11:34 Voltage Offset Correction: v_off_ini = 755.412 uV, v_off_fin = 744.158 uV 16:11:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.022 uVs 16:11:34 Integrated Voltage Measurement... 16:11:43 Voltage Offset Correction: v_off_ini = 745.907 uV, v_off_fin = 756.340 uV 16:11:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.030 uVs 16:11:43 Integrated Voltage Measurement... 16:11:52 Voltage Offset Correction: v_off_ini = 762.833 uV, v_off_fin = 755.436 uV 16:11:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.317 uVs 16:11:52 Integrated Voltage Measurement... 16:12:01 Voltage Offset Correction: v_off_ini = 747.879 uV, v_off_fin = 759.257 uV 16:12:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.397 uVs 16:12:05 I1Y Average and RMS of Measurements VT = -194.168 +- 4.264 uVs I1Y = -38.834 +- 0.852 uTm 16:12:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:12:13 Integrated Voltage Measurement... 16:12:22 Voltage Offset Correction: v_off_ini = 741.657 uV, v_off_fin = 735.182 uV 16:12:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.450 uVs 16:12:22 Integrated Voltage Measurement... 16:12:31 Voltage Offset Correction: v_off_ini = 754.332 uV, v_off_fin = 752.799 uV 16:12:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.999 uVs 16:12:31 Integrated Voltage Measurement... 16:12:40 Voltage Offset Correction: v_off_ini = 735.085 uV, v_off_fin = 702.217 uV 16:12:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.732 uVs 16:12:40 Integrated Voltage Measurement... 16:12:49 Voltage Offset Correction: v_off_ini = 728.269 uV, v_off_fin = 742.871 uV 16:12:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.048 uVs 16:12:49 Integrated Voltage Measurement... 16:12:58 Voltage Offset Correction: v_off_ini = 738.657 uV, v_off_fin = 737.522 uV 16:12:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.291 uVs 16:12:58 Integrated Voltage Measurement... 16:13:07 Voltage Offset Correction: v_off_ini = 738.017 uV, v_off_fin = 745.702 uV 16:13:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.282 uVs 16:13:09 I2X Average and RMS of Measurements VT = -110.134 +- 1.704 uVs I2X = 10.132 +- 0.157 uTm^2 16:13:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:13:17 Integrated Voltage Measurement... 16:13:26 Voltage Offset Correction: v_off_ini = 771.749 uV, v_off_fin = 754.749 uV 16:13:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.210 uVs 16:13:26 Integrated Voltage Measurement... 16:13:35 Voltage Offset Correction: v_off_ini = 764.704 uV, v_off_fin = 747.735 uV 16:13:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.787 uVs 16:13:35 Integrated Voltage Measurement... 16:13:44 Voltage Offset Correction: v_off_ini = 758.351 uV, v_off_fin = 761.161 uV 16:13:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.706 uVs 16:13:44 Integrated Voltage Measurement... 16:13:53 Voltage Offset Correction: v_off_ini = 751.305 uV, v_off_fin = 750.320 uV 16:13:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.922 uVs 16:13:53 Integrated Voltage Measurement... 16:14:02 Voltage Offset Correction: v_off_ini = 734.591 uV, v_off_fin = 763.069 uV 16:14:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.055 uVs 16:14:02 Integrated Voltage Measurement... 16:14:11 Voltage Offset Correction: v_off_ini = 772.264 uV, v_off_fin = 768.822 uV 16:14:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.786 uVs 16:14:14 I2Y Average and RMS of Measurements VT = -248.244 +- 4.619 uVs I2Y = -22.838 +- 0.425 uTm^2 16:14:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:23 Integrated Voltage Measurement... 16:14:32 Voltage Offset Correction: v_off_ini = 778.448 uV, v_off_fin = 768.327 uV 16:14:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.653 uVs 16:14:32 Integrated Voltage Measurement... 16:14:41 Voltage Offset Correction: v_off_ini = 780.225 uV, v_off_fin = 753.234 uV 16:14:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.367 uVs 16:14:41 Integrated Voltage Measurement... 16:14:50 Voltage Offset Correction: v_off_ini = 764.652 uV, v_off_fin = 760.037 uV 16:14:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.168 uVs 16:14:50 Integrated Voltage Measurement... 16:14:59 Voltage Offset Correction: v_off_ini = 768.400 uV, v_off_fin = 767.411 uV 16:14:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.234 uVs 16:14:59 Integrated Voltage Measurement... 16:15:08 Voltage Offset Correction: v_off_ini = 776.463 uV, v_off_fin = 755.573 uV 16:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.288 uVs 16:15:08 Integrated Voltage Measurement... 16:15:17 Voltage Offset Correction: v_off_ini = 760.345 uV, v_off_fin = 767.419 uV 16:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.328 uVs 16:15:21 I1X Average and RMS of Measurements VT = -84.006 +- 1.808 uVs I1X = 16.802 +- 0.362 uTm 16:15:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:28 Integrated Voltage Measurement... 16:15:37 Voltage Offset Correction: v_off_ini = 767.549 uV, v_off_fin = 762.018 uV 16:15:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.839 uVs 16:15:37 Integrated Voltage Measurement... 16:15:46 Voltage Offset Correction: v_off_ini = 764.988 uV, v_off_fin = 756.751 uV 16:15:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.835 uVs 16:15:46 Integrated Voltage Measurement... 16:15:55 Voltage Offset Correction: v_off_ini = 783.028 uV, v_off_fin = 764.434 uV 16:15:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.601 uVs 16:15:55 Integrated Voltage Measurement... 16:16:04 Voltage Offset Correction: v_off_ini = 766.740 uV, v_off_fin = 793.450 uV 16:16:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.945 uVs 16:16:04 Integrated Voltage Measurement... 16:16:13 Voltage Offset Correction: v_off_ini = 767.319 uV, v_off_fin = 769.160 uV 16:16:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.594 uVs 16:16:13 Integrated Voltage Measurement... 16:16:22 Voltage Offset Correction: v_off_ini = 775.698 uV, v_off_fin = 768.844 uV 16:16:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.761 uVs 16:16:26 I1Y Average and RMS of Measurements VT = -183.262 +- 5.493 uVs I1Y = -36.652 +- 1.099 uTm 16:16:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:34 Integrated Voltage Measurement... 16:16:43 Voltage Offset Correction: v_off_ini = 715.586 uV, v_off_fin = 719.388 uV 16:16:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.473 uVs 16:16:43 Integrated Voltage Measurement... 16:16:52 Voltage Offset Correction: v_off_ini = 737.676 uV, v_off_fin = 745.782 uV 16:16:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.717 uVs 16:16:52 Integrated Voltage Measurement... 16:17:01 Voltage Offset Correction: v_off_ini = 715.914 uV, v_off_fin = 711.303 uV 16:17:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.043 uVs 16:17:01 Integrated Voltage Measurement... 16:17:10 Voltage Offset Correction: v_off_ini = 706.104 uV, v_off_fin = 715.828 uV 16:17:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.286 uVs 16:17:10 Integrated Voltage Measurement... 16:17:19 Voltage Offset Correction: v_off_ini = 717.828 uV, v_off_fin = 722.006 uV 16:17:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.565 uVs 16:17:19 Integrated Voltage Measurement... 16:17:28 Voltage Offset Correction: v_off_ini = 727.263 uV, v_off_fin = 738.317 uV 16:17:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.653 uVs 16:17:30 I2X Average and RMS of Measurements VT = -100.789 +- 3.494 uVs I2X = 9.273 +- 0.321 uTm^2 16:17:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:17:38 Integrated Voltage Measurement... 16:17:47 Voltage Offset Correction: v_off_ini = 743.653 uV, v_off_fin = 731.574 uV 16:17:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.688 uVs 16:17:47 Integrated Voltage Measurement... 16:17:56 Voltage Offset Correction: v_off_ini = 727.154 uV, v_off_fin = 728.521 uV 16:17:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.386 uVs 16:17:56 Integrated Voltage Measurement... 16:18:05 Voltage Offset Correction: v_off_ini = 730.162 uV, v_off_fin = 736.238 uV 16:18:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.283 uVs 16:18:05 Integrated Voltage Measurement... 16:18:14 Voltage Offset Correction: v_off_ini = 739.987 uV, v_off_fin = 737.132 uV 16:18:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.251 uVs 16:18:14 Integrated Voltage Measurement... 16:18:23 Voltage Offset Correction: v_off_ini = 715.392 uV, v_off_fin = 743.903 uV 16:18:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.965 uVs 16:18:23 Integrated Voltage Measurement... 16:18:32 Voltage Offset Correction: v_off_ini = 720.094 uV, v_off_fin = 718.123 uV 16:18:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.189 uVs 16:18:35 I2Y Average and RMS of Measurements VT = -242.460 +- 5.532 uVs I2Y = -22.306 +- 0.509 uTm^2 16:18:39 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:18:44 Integrated Voltage Measurement... 16:18:53 Voltage Offset Correction: v_off_ini = 729.963 uV, v_off_fin = 727.795 uV 16:18:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.379 uVs 16:18:53 Integrated Voltage Measurement... 16:19:02 Voltage Offset Correction: v_off_ini = 732.328 uV, v_off_fin = 728.897 uV 16:19:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.741 uVs 16:19:02 Integrated Voltage Measurement... 16:19:11 Voltage Offset Correction: v_off_ini = 712.190 uV, v_off_fin = 703.370 uV 16:19:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.983 uVs 16:19:11 Integrated Voltage Measurement... 16:19:20 Voltage Offset Correction: v_off_ini = 711.368 uV, v_off_fin = 724.477 uV 16:19:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.001 uVs 16:19:20 Integrated Voltage Measurement... 16:19:29 Voltage Offset Correction: v_off_ini = 705.888 uV, v_off_fin = 712.609 uV 16:19:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.275 uVs 16:19:29 Integrated Voltage Measurement... 16:19:38 Voltage Offset Correction: v_off_ini = 727.286 uV, v_off_fin = 721.329 uV 16:19:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.620 uVs 16:19:42 I1X Average and RMS of Measurements VT = -74.333 +- 12.097 uVs I1X = 14.867 +- 2.419 uTm 16:19:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:19:49 Integrated Voltage Measurement... 16:19:58 Voltage Offset Correction: v_off_ini = 732.027 uV, v_off_fin = 714.702 uV 16:19:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.735 uVs 16:19:58 Integrated Voltage Measurement... 16:20:07 Voltage Offset Correction: v_off_ini = 727.029 uV, v_off_fin = 736.784 uV 16:20:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.002 uVs 16:20:07 Integrated Voltage Measurement... 16:20:16 Voltage Offset Correction: v_off_ini = 738.610 uV, v_off_fin = 732.007 uV 16:20:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.625 uVs 16:20:16 Integrated Voltage Measurement... 16:20:25 Voltage Offset Correction: v_off_ini = 738.676 uV, v_off_fin = 743.735 uV 16:20:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.365 uVs 16:20:25 Integrated Voltage Measurement... 16:20:34 Voltage Offset Correction: v_off_ini = 723.624 uV, v_off_fin = 736.526 uV 16:20:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.416 uVs 16:20:34 Integrated Voltage Measurement... 16:20:43 Voltage Offset Correction: v_off_ini = 761.577 uV, v_off_fin = 729.027 uV 16:20:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.715 uVs 16:20:47 I1Y Average and RMS of Measurements VT = -189.810 +- 3.238 uVs I1Y = -37.962 +- 0.648 uTm 16:20:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:20:54 Integrated Voltage Measurement... 16:21:03 Voltage Offset Correction: v_off_ini = 728.054 uV, v_off_fin = 713.516 uV 16:21:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.658 uVs 16:21:03 Integrated Voltage Measurement... 16:21:12 Voltage Offset Correction: v_off_ini = 726.955 uV, v_off_fin = 709.081 uV 16:21:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.426 uVs 16:21:13 Integrated Voltage Measurement... 16:21:21 Voltage Offset Correction: v_off_ini = 678.411 uV, v_off_fin = 690.440 uV 16:21:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.457 uVs 16:21:22 Integrated Voltage Measurement... 16:21:31 Voltage Offset Correction: v_off_ini = 708.563 uV, v_off_fin = 706.554 uV 16:21:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.670 uVs 16:21:31 Integrated Voltage Measurement... 16:21:40 Voltage Offset Correction: v_off_ini = 708.357 uV, v_off_fin = 709.413 uV 16:21:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.857 uVs 16:21:40 Integrated Voltage Measurement... 16:21:49 Voltage Offset Correction: v_off_ini = 716.771 uV, v_off_fin = 733.598 uV 16:21:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.899 uVs 16:21:51 I2X Average and RMS of Measurements VT = -91.495 +- 4.928 uVs I2X = 8.418 +- 0.453 uTm^2 16:21:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:21:59 Integrated Voltage Measurement... 16:22:08 Voltage Offset Correction: v_off_ini = 727.240 uV, v_off_fin = 729.584 uV 16:22:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.637 uVs 16:22:08 Integrated Voltage Measurement... 16:22:17 Voltage Offset Correction: v_off_ini = 721.865 uV, v_off_fin = 708.168 uV 16:22:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.211 uVs 16:22:17 Integrated Voltage Measurement... 16:22:26 Voltage Offset Correction: v_off_ini = 719.722 uV, v_off_fin = 720.694 uV 16:22:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.935 uVs 16:22:26 Integrated Voltage Measurement... 16:22:35 Voltage Offset Correction: v_off_ini = 725.026 uV, v_off_fin = 696.625 uV 16:22:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.110 uVs 16:22:35 Integrated Voltage Measurement... 16:22:44 Voltage Offset Correction: v_off_ini = 710.276 uV, v_off_fin = 713.050 uV 16:22:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.797 uVs 16:22:44 Integrated Voltage Measurement... 16:22:53 Voltage Offset Correction: v_off_ini = 703.159 uV, v_off_fin = 700.439 uV 16:22:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.234 uVs 16:22:55 I2Y Average and RMS of Measurements VT = -246.654 +- 2.856 uVs I2Y = -22.692 +- 0.263 uTm^2 16:23:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:23:04 Integrated Voltage Measurement... 16:23:13 Voltage Offset Correction: v_off_ini = 718.185 uV, v_off_fin = 728.104 uV 16:23:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -81.852 uVs 16:23:13 Integrated Voltage Measurement... 16:23:22 Voltage Offset Correction: v_off_ini = 704.686 uV, v_off_fin = 705.149 uV 16:23:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.725 uVs 16:23:22 Integrated Voltage Measurement... 16:23:31 Voltage Offset Correction: v_off_ini = 712.879 uV, v_off_fin = 714.444 uV 16:23:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.388 uVs 16:23:31 Integrated Voltage Measurement... 16:23:40 Voltage Offset Correction: v_off_ini = 719.267 uV, v_off_fin = 733.262 uV 16:23:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.284 uVs 16:23:40 Integrated Voltage Measurement... 16:23:49 Voltage Offset Correction: v_off_ini = 720.134 uV, v_off_fin = 729.398 uV 16:23:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.661 uVs 16:23:49 Integrated Voltage Measurement... 16:23:58 Voltage Offset Correction: v_off_ini = 711.963 uV, v_off_fin = 713.068 uV 16:23:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.120 uVs 16:24:02 I1X Average and RMS of Measurements VT = -75.172 +- 7.367 uVs I1X = 15.035 +- 1.475 uTm 16:24:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:24:09 Integrated Voltage Measurement... 16:24:18 Voltage Offset Correction: v_off_ini = 721.158 uV, v_off_fin = 719.638 uV 16:24:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.847 uVs 16:24:18 Integrated Voltage Measurement... 16:24:27 Voltage Offset Correction: v_off_ini = 712.472 uV, v_off_fin = 703.226 uV 16:24:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.399 uVs 16:24:27 Integrated Voltage Measurement... 16:24:36 Voltage Offset Correction: v_off_ini = 693.835 uV, v_off_fin = 674.088 uV 16:24:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.249 uVs 16:24:36 Integrated Voltage Measurement... 16:24:45 Voltage Offset Correction: v_off_ini = 679.427 uV, v_off_fin = 699.770 uV 16:24:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.979 uVs 16:24:45 Integrated Voltage Measurement... 16:24:54 Voltage Offset Correction: v_off_ini = 690.713 uV, v_off_fin = 689.599 uV 16:24:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.378 uVs 16:24:54 Integrated Voltage Measurement... 16:25:03 Voltage Offset Correction: v_off_ini = 672.958 uV, v_off_fin = 682.984 uV 16:25:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.905 uVs 16:25:07 I1Y Average and RMS of Measurements VT = -180.460 +- 8.961 uVs I1Y = -36.092 +- 1.792 uTm 16:25:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:25:15 Integrated Voltage Measurement... 16:25:23 Voltage Offset Correction: v_off_ini = 694.245 uV, v_off_fin = 666.156 uV 16:25:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.378 uVs 16:25:24 Integrated Voltage Measurement... 16:25:33 Voltage Offset Correction: v_off_ini = 698.911 uV, v_off_fin = 694.225 uV 16:25:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.809 uVs 16:25:33 Integrated Voltage Measurement... 16:25:42 Voltage Offset Correction: v_off_ini = 694.237 uV, v_off_fin = 691.948 uV 16:25:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.623 uVs 16:25:42 Integrated Voltage Measurement... 16:25:51 Voltage Offset Correction: v_off_ini = 694.630 uV, v_off_fin = 698.984 uV 16:25:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.907 uVs 16:25:51 Integrated Voltage Measurement... 16:26:00 Voltage Offset Correction: v_off_ini = 675.541 uV, v_off_fin = 688.935 uV 16:26:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.042 uVs 16:26:00 Integrated Voltage Measurement... 16:26:09 Voltage Offset Correction: v_off_ini = 701.393 uV, v_off_fin = 711.937 uV 16:26:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.509 uVs 16:26:11 I2X Average and RMS of Measurements VT = -86.045 +- 5.990 uVs I2X = 7.916 +- 0.551 uTm^2 16:26:16 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:26:19 Integrated Voltage Measurement... 16:26:28 Voltage Offset Correction: v_off_ini = 704.464 uV, v_off_fin = 702.399 uV 16:26:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.604 uVs 16:26:28 Integrated Voltage Measurement... 16:26:37 Voltage Offset Correction: v_off_ini = 711.593 uV, v_off_fin = 720.137 uV 16:26:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.020 uVs 16:26:37 Integrated Voltage Measurement... 16:26:46 Voltage Offset Correction: v_off_ini = 705.746 uV, v_off_fin = 705.048 uV 16:26:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.231 uVs 16:26:46 Integrated Voltage Measurement... 16:26:55 Voltage Offset Correction: v_off_ini = 697.987 uV, v_off_fin = 703.950 uV 16:26:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.399 uVs 16:26:55 Integrated Voltage Measurement... 16:27:04 Voltage Offset Correction: v_off_ini = 709.651 uV, v_off_fin = 716.537 uV 16:27:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.624 uVs 16:27:04 Integrated Voltage Measurement... 16:27:13 Voltage Offset Correction: v_off_ini = 734.192 uV, v_off_fin = 719.573 uV 16:27:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.704 uVs 16:27:15 I2Y Average and RMS of Measurements VT = -235.597 +- 5.993 uVs I2Y = -21.675 +- 0.551 uTm^2 16:27:23 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:27:27 Integrated Voltage Measurement... 16:27:36 Voltage Offset Correction: v_off_ini = 703.780 uV, v_off_fin = 704.657 uV 16:27:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.661 uVs 16:27:36 Integrated Voltage Measurement... 16:27:45 Voltage Offset Correction: v_off_ini = 725.350 uV, v_off_fin = 723.048 uV 16:27:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.067 uVs 16:27:45 Integrated Voltage Measurement... 16:27:54 Voltage Offset Correction: v_off_ini = 731.367 uV, v_off_fin = 741.269 uV 16:27:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.802 uVs 16:27:54 Integrated Voltage Measurement... 16:28:03 Voltage Offset Correction: v_off_ini = 720.617 uV, v_off_fin = 706.657 uV 16:28:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.128 uVs 16:28:03 Integrated Voltage Measurement... 16:28:12 Voltage Offset Correction: v_off_ini = 719.439 uV, v_off_fin = 704.515 uV 16:28:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.638 uVs 16:28:12 Integrated Voltage Measurement... 16:28:21 Voltage Offset Correction: v_off_ini = 718.580 uV, v_off_fin = 726.397 uV 16:28:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.164 uVs 16:28:25 I1X Average and RMS of Measurements VT = -91.410 +- 10.848 uVs I1X = 18.282 +- 2.170 uTm 16:28:28 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:28:32 Integrated Voltage Measurement... 16:28:41 Voltage Offset Correction: v_off_ini = 697.105 uV, v_off_fin = 706.577 uV 16:28:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.595 uVs 16:28:41 Integrated Voltage Measurement... 16:28:50 Voltage Offset Correction: v_off_ini = 716.348 uV, v_off_fin = 709.241 uV 16:28:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.909 uVs 16:28:50 Integrated Voltage Measurement... 16:28:59 Voltage Offset Correction: v_off_ini = 706.690 uV, v_off_fin = 693.906 uV 16:28:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.466 uVs 16:28:59 Integrated Voltage Measurement... 16:29:08 Voltage Offset Correction: v_off_ini = 736.532 uV, v_off_fin = 744.467 uV 16:29:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.690 uVs 16:29:08 Integrated Voltage Measurement... 16:29:17 Voltage Offset Correction: v_off_ini = 727.826 uV, v_off_fin = 729.753 uV 16:29:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.104 uVs 16:29:17 Integrated Voltage Measurement... 16:29:26 Voltage Offset Correction: v_off_ini = 715.493 uV, v_off_fin = 725.240 uV 16:29:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.735 uVs 16:29:30 I1Y Average and RMS of Measurements VT = -192.583 +- 6.167 uVs I1Y = -38.517 +- 1.233 uTm 16:29:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:29:35 Integrated Voltage Measurement... 16:29:44 Voltage Offset Correction: v_off_ini = 664.837 uV, v_off_fin = 683.172 uV 16:29:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.391 uVs 16:29:44 Integrated Voltage Measurement... 16:29:53 Voltage Offset Correction: v_off_ini = 685.533 uV, v_off_fin = 700.353 uV 16:29:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.340 uVs 16:29:53 Integrated Voltage Measurement... 16:30:02 Voltage Offset Correction: v_off_ini = 704.768 uV, v_off_fin = 711.023 uV 16:30:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.732 uVs 16:30:02 Integrated Voltage Measurement... 16:30:11 Voltage Offset Correction: v_off_ini = 701.250 uV, v_off_fin = 709.394 uV 16:30:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.763 uVs 16:30:11 Integrated Voltage Measurement... 16:30:20 Voltage Offset Correction: v_off_ini = 705.777 uV, v_off_fin = 691.475 uV 16:30:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.973 uVs 16:30:20 Integrated Voltage Measurement... 16:30:29 Voltage Offset Correction: v_off_ini = 709.088 uV, v_off_fin = 715.848 uV 16:30:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.918 uVs 16:30:31 I2X Average and RMS of Measurements VT = -116.019 +- 1.790 uVs I2X = 10.674 +- 0.165 uTm^2 16:30:34 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:30:36 Integrated Voltage Measurement... 16:30:45 Voltage Offset Correction: v_off_ini = 707.884 uV, v_off_fin = 696.314 uV 16:30:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.419 uVs 16:30:45 Integrated Voltage Measurement... 16:30:54 Voltage Offset Correction: v_off_ini = 702.109 uV, v_off_fin = 705.358 uV 16:30:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.026 uVs 16:30:54 Integrated Voltage Measurement... 16:31:03 Voltage Offset Correction: v_off_ini = 708.335 uV, v_off_fin = 708.323 uV 16:31:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.358 uVs 16:31:03 Integrated Voltage Measurement... 16:31:12 Voltage Offset Correction: v_off_ini = 698.178 uV, v_off_fin = 693.355 uV 16:31:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.119 uVs 16:31:12 Integrated Voltage Measurement... 16:31:21 Voltage Offset Correction: v_off_ini = 717.654 uV, v_off_fin = 708.515 uV 16:31:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.594 uVs 16:31:21 Integrated Voltage Measurement... 16:31:30 Voltage Offset Correction: v_off_ini = 694.021 uV, v_off_fin = 713.558 uV 16:31:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.470 uVs 16:31:33 I2Y Average and RMS of Measurements VT = -247.331 +- 9.423 uVs I2Y = -22.754 +- 0.867 uTm^2 16:31:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:31:41 Integrated Voltage Measurement... 16:31:50 Voltage Offset Correction: v_off_ini = 718.909 uV, v_off_fin = 699.276 uV 16:31:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -84.351 uVs 16:31:50 Integrated Voltage Measurement... 16:31:59 Voltage Offset Correction: v_off_ini = 677.554 uV, v_off_fin = 686.921 uV 16:31:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.714 uVs 16:31:59 Integrated Voltage Measurement... 16:32:08 Voltage Offset Correction: v_off_ini = 684.940 uV, v_off_fin = 700.931 uV 16:32:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.644 uVs 16:32:08 Integrated Voltage Measurement... 16:32:17 Voltage Offset Correction: v_off_ini = 706.695 uV, v_off_fin = 722.561 uV 16:32:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.297 uVs 16:32:17 Integrated Voltage Measurement... 16:32:26 Voltage Offset Correction: v_off_ini = 709.855 uV, v_off_fin = 704.984 uV 16:32:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.670 uVs 16:32:26 Integrated Voltage Measurement... 16:32:35 Voltage Offset Correction: v_off_ini = 681.619 uV, v_off_fin = 710.584 uV 16:32:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.366 uVs 16:32:39 I1X Average and RMS of Measurements VT = -89.674 +- 10.969 uVs I1X = 17.936 +- 2.193 uTm 16:32:42 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:32:46 Integrated Voltage Measurement... 16:32:55 Voltage Offset Correction: v_off_ini = 720.651 uV, v_off_fin = 720.146 uV 16:32:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.583 uVs 16:32:55 Integrated Voltage Measurement... 16:33:04 Voltage Offset Correction: v_off_ini = 716.278 uV, v_off_fin = 725.574 uV 16:33:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.318 uVs 16:33:04 Integrated Voltage Measurement... 16:33:13 Voltage Offset Correction: v_off_ini = 711.274 uV, v_off_fin = 704.255 uV 16:33:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.969 uVs 16:33:13 Integrated Voltage Measurement... 16:33:22 Voltage Offset Correction: v_off_ini = 714.224 uV, v_off_fin = 718.628 uV 16:33:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.039 uVs 16:33:22 Integrated Voltage Measurement... 16:33:31 Voltage Offset Correction: v_off_ini = 672.978 uV, v_off_fin = 678.182 uV 16:33:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.708 uVs 16:33:31 Integrated Voltage Measurement... 16:33:40 Voltage Offset Correction: v_off_ini = 706.715 uV, v_off_fin = 704.541 uV 16:33:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.519 uVs 16:33:44 I1Y Average and RMS of Measurements VT = -185.190 +- 1.800 uVs I1Y = -37.038 +- 0.360 uTm 16:33:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:33:49 Integrated Voltage Measurement... 16:33:58 Voltage Offset Correction: v_off_ini = 693.027 uV, v_off_fin = 680.987 uV 16:33:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.528 uVs 16:33:58 Integrated Voltage Measurement... 16:34:07 Voltage Offset Correction: v_off_ini = 697.763 uV, v_off_fin = 688.861 uV 16:34:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.200 uVs 16:34:07 Integrated Voltage Measurement... 16:34:16 Voltage Offset Correction: v_off_ini = 694.806 uV, v_off_fin = 684.313 uV 16:34:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.014 uVs 16:34:16 Integrated Voltage Measurement... 16:34:25 Voltage Offset Correction: v_off_ini = 677.682 uV, v_off_fin = 689.149 uV 16:34:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.890 uVs 16:34:25 Integrated Voltage Measurement... 16:34:34 Voltage Offset Correction: v_off_ini = 703.410 uV, v_off_fin = 688.113 uV 16:34:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.212 uVs 16:34:34 Integrated Voltage Measurement... 16:34:43 Voltage Offset Correction: v_off_ini = 674.393 uV, v_off_fin = 698.870 uV 16:34:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.202 uVs 16:34:46 I2X Average and RMS of Measurements VT = -108.008 +- 9.248 uVs I2X = 9.937 +- 0.851 uTm^2 16:34:48 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:34:51 Integrated Voltage Measurement... 16:35:00 Voltage Offset Correction: v_off_ini = 707.506 uV, v_off_fin = 694.049 uV 16:35:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.528 uVs 16:35:00 Integrated Voltage Measurement... 16:35:09 Voltage Offset Correction: v_off_ini = 685.135 uV, v_off_fin = 718.243 uV 16:35:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.797 uVs 16:35:09 Integrated Voltage Measurement... 16:35:18 Voltage Offset Correction: v_off_ini = 723.599 uV, v_off_fin = 713.903 uV 16:35:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.214 uVs 16:35:18 Integrated Voltage Measurement... 16:35:27 Voltage Offset Correction: v_off_ini = 724.334 uV, v_off_fin = 712.586 uV 16:35:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.739 uVs 16:35:27 Integrated Voltage Measurement... 16:35:36 Voltage Offset Correction: v_off_ini = 707.593 uV, v_off_fin = 715.175 uV 16:35:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.819 uVs 16:35:36 Integrated Voltage Measurement... 16:35:45 Voltage Offset Correction: v_off_ini = 747.651 uV, v_off_fin = 742.097 uV 16:35:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.122 uVs 16:35:47 I2Y Average and RMS of Measurements VT = -241.870 +- 14.904 uVs I2Y = -22.252 +- 1.371 uTm^2 16:35:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:56 Integrated Voltage Measurement... 16:36:05 Voltage Offset Correction: v_off_ini = 716.438 uV, v_off_fin = 704.307 uV 16:36:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.321 uVs 16:36:05 Integrated Voltage Measurement... 16:36:14 Voltage Offset Correction: v_off_ini = 713.476 uV, v_off_fin = 716.234 uV 16:36:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.783 uVs 16:36:14 Integrated Voltage Measurement... 16:36:23 Voltage Offset Correction: v_off_ini = 709.285 uV, v_off_fin = 708.362 uV 16:36:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.733 uVs 16:36:23 Integrated Voltage Measurement... 16:36:32 Voltage Offset Correction: v_off_ini = 741.227 uV, v_off_fin = 721.304 uV 16:36:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.037 uVs 16:36:32 Integrated Voltage Measurement... 16:36:41 Voltage Offset Correction: v_off_ini = 698.277 uV, v_off_fin = 699.772 uV 16:36:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -71.484 uVs 16:36:41 Integrated Voltage Measurement... 16:36:50 Voltage Offset Correction: v_off_ini = 716.963 uV, v_off_fin = 723.900 uV 16:36:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 85.744 uVs 16:36:54 I1X Average and RMS of Measurements VT = -84.350 +- 9.362 uVs I1X = 16.871 +- 1.872 uTm 16:36:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:01 Integrated Voltage Measurement... 16:37:10 Voltage Offset Correction: v_off_ini = 715.217 uV, v_off_fin = 709.809 uV 16:37:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -173.988 uVs 16:37:10 Integrated Voltage Measurement... 16:37:19 Voltage Offset Correction: v_off_ini = 713.589 uV, v_off_fin = 710.906 uV 16:37:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.806 uVs 16:37:19 Integrated Voltage Measurement... 16:37:28 Voltage Offset Correction: v_off_ini = 682.249 uV, v_off_fin = 692.836 uV 16:37:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.692 uVs 16:37:28 Integrated Voltage Measurement... 16:37:37 Voltage Offset Correction: v_off_ini = 721.131 uV, v_off_fin = 714.575 uV 16:37:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.208 uVs 16:37:37 Integrated Voltage Measurement... 16:37:46 Voltage Offset Correction: v_off_ini = 689.565 uV, v_off_fin = 680.804 uV 16:37:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.113 uVs 16:37:46 Integrated Voltage Measurement... 16:37:55 Voltage Offset Correction: v_off_ini = 704.765 uV, v_off_fin = 715.824 uV 16:37:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.284 uVs 16:37:59 I1Y Average and RMS of Measurements VT = -180.348 +- 1.531 uVs I1Y = -36.068 +- 0.305 uTm 16:38:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:38:04 Integrated Voltage Measurement... 16:38:13 Voltage Offset Correction: v_off_ini = 700.055 uV, v_off_fin = 708.885 uV 16:38:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.044 uVs 16:38:13 Integrated Voltage Measurement... 16:38:22 Voltage Offset Correction: v_off_ini = 714.651 uV, v_off_fin = 708.157 uV 16:38:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.259 uVs 16:38:22 Integrated Voltage Measurement... 16:38:31 Voltage Offset Correction: v_off_ini = 701.116 uV, v_off_fin = 683.938 uV 16:38:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.372 uVs 16:38:31 Integrated Voltage Measurement... 16:38:40 Voltage Offset Correction: v_off_ini = 699.849 uV, v_off_fin = 714.519 uV 16:38:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.700 uVs 16:38:40 Integrated Voltage Measurement... 16:38:49 Voltage Offset Correction: v_off_ini = 714.971 uV, v_off_fin = 703.798 uV 16:38:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.699 uVs 16:38:49 Integrated Voltage Measurement... 16:38:58 Voltage Offset Correction: v_off_ini = 702.482 uV, v_off_fin = 696.353 uV 16:38:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.089 uVs 16:39:01 I2X Average and RMS of Measurements VT = -103.360 +- 4.143 uVs I2X = 9.509 +- 0.381 uTm^2 16:39:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:06 Integrated Voltage Measurement... 16:39:15 Voltage Offset Correction: v_off_ini = 694.483 uV, v_off_fin = 704.615 uV 16:39:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.906 uVs 16:39:15 Integrated Voltage Measurement... 16:39:24 Voltage Offset Correction: v_off_ini = 695.794 uV, v_off_fin = 696.325 uV 16:39:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.724 uVs 16:39:24 Integrated Voltage Measurement... 16:39:33 Voltage Offset Correction: v_off_ini = 681.881 uV, v_off_fin = 684.077 uV 16:39:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.545 uVs 16:39:33 Integrated Voltage Measurement... 16:39:42 Voltage Offset Correction: v_off_ini = 666.276 uV, v_off_fin = 682.868 uV 16:39:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.803 uVs 16:39:42 Integrated Voltage Measurement... 16:39:51 Voltage Offset Correction: v_off_ini = 693.626 uV, v_off_fin = 681.635 uV 16:39:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.724 uVs 16:39:51 Integrated Voltage Measurement... 16:40:00 Voltage Offset Correction: v_off_ini = 669.333 uV, v_off_fin = 676.736 uV 16:40:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.422 uVs 16:40:02 I2Y Average and RMS of Measurements VT = -241.521 +- 2.967 uVs I2Y = -22.220 +- 0.273 uTm^2 16:40:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:40:11 Integrated Voltage Measurement... 16:40:20 Voltage Offset Correction: v_off_ini = 675.450 uV, v_off_fin = 679.451 uV 16:40:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.019 uVs 16:40:20 Integrated Voltage Measurement... 16:40:29 Voltage Offset Correction: v_off_ini = 681.449 uV, v_off_fin = 691.360 uV 16:40:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.933 uVs 16:40:29 Integrated Voltage Measurement... 16:40:38 Voltage Offset Correction: v_off_ini = 671.222 uV, v_off_fin = 670.636 uV 16:40:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.627 uVs 16:40:38 Integrated Voltage Measurement... 16:40:47 Voltage Offset Correction: v_off_ini = 679.055 uV, v_off_fin = 666.452 uV 16:40:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.121 uVs 16:40:47 Integrated Voltage Measurement... 16:40:56 Voltage Offset Correction: v_off_ini = 674.755 uV, v_off_fin = 666.461 uV 16:40:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.917 uVs 16:40:56 Integrated Voltage Measurement... 16:41:05 Voltage Offset Correction: v_off_ini = 684.927 uV, v_off_fin = 671.570 uV 16:41:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.307 uVs 16:41:09 I1X Average and RMS of Measurements VT = -79.987 +- 0.789 uVs I1X = 15.998 +- 0.158 uTm 16:41:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:41:16 Integrated Voltage Measurement... 16:41:25 Voltage Offset Correction: v_off_ini = 685.403 uV, v_off_fin = 654.090 uV 16:41:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.688 uVs 16:41:25 Integrated Voltage Measurement... 16:41:34 Voltage Offset Correction: v_off_ini = 668.142 uV, v_off_fin = 690.829 uV 16:41:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 176.496 uVs 16:41:34 Integrated Voltage Measurement... 16:41:43 Voltage Offset Correction: v_off_ini = 677.151 uV, v_off_fin = 669.546 uV 16:41:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.587 uVs 16:41:43 Integrated Voltage Measurement... 16:41:52 Voltage Offset Correction: v_off_ini = 673.876 uV, v_off_fin = 694.492 uV 16:41:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.326 uVs 16:41:52 Integrated Voltage Measurement... 16:42:01 Voltage Offset Correction: v_off_ini = 687.336 uV, v_off_fin = 674.549 uV 16:42:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.962 uVs 16:42:01 Integrated Voltage Measurement... 16:42:10 Voltage Offset Correction: v_off_ini = 674.510 uV, v_off_fin = 690.845 uV 16:42:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 165.289 uVs 16:42:14 I1Y Average and RMS of Measurements VT = -179.058 +- 3.486 uVs I1Y = -35.810 +- 0.697 uTm 16:42:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:42:19 Integrated Voltage Measurement... 16:42:28 Voltage Offset Correction: v_off_ini = 651.867 uV, v_off_fin = 660.257 uV 16:42:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.093 uVs 16:42:28 Integrated Voltage Measurement... 16:42:37 Voltage Offset Correction: v_off_ini = 657.243 uV, v_off_fin = 677.271 uV 16:42:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.904 uVs 16:42:37 Integrated Voltage Measurement... 16:42:46 Voltage Offset Correction: v_off_ini = 679.970 uV, v_off_fin = 666.522 uV 16:42:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.152 uVs 16:42:46 Integrated Voltage Measurement... 16:42:55 Voltage Offset Correction: v_off_ini = 667.603 uV, v_off_fin = 668.489 uV 16:42:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.737 uVs 16:42:55 Integrated Voltage Measurement... 16:43:04 Voltage Offset Correction: v_off_ini = 660.724 uV, v_off_fin = 655.698 uV 16:43:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.909 uVs 16:43:04 Integrated Voltage Measurement... 16:43:13 Voltage Offset Correction: v_off_ini = 662.128 uV, v_off_fin = 685.246 uV 16:43:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 106.214 uVs 16:43:16 I2X Average and RMS of Measurements VT = -107.002 +- 6.324 uVs I2X = 9.844 +- 0.582 uTm^2 16:43:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:43:21 Integrated Voltage Measurement... 16:43:30 Voltage Offset Correction: v_off_ini = 669.565 uV, v_off_fin = 676.357 uV 16:43:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.582 uVs 16:43:30 Integrated Voltage Measurement... 16:43:39 Voltage Offset Correction: v_off_ini = 687.707 uV, v_off_fin = 684.705 uV 16:43:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.288 uVs 16:43:39 Integrated Voltage Measurement... 16:43:48 Voltage Offset Correction: v_off_ini = 688.053 uV, v_off_fin = 691.956 uV 16:43:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.242 uVs 16:43:48 Integrated Voltage Measurement... 16:43:57 Voltage Offset Correction: v_off_ini = 701.468 uV, v_off_fin = 695.302 uV 16:43:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.474 uVs 16:43:57 Integrated Voltage Measurement... 16:44:06 Voltage Offset Correction: v_off_ini = 692.887 uV, v_off_fin = 697.294 uV 16:44:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.266 uVs 16:44:06 Integrated Voltage Measurement... 16:44:15 Voltage Offset Correction: v_off_ini = 698.169 uV, v_off_fin = 690.703 uV 16:44:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.864 uVs 16:44:18 I2Y Average and RMS of Measurements VT = -225.953 +- 2.166 uVs I2Y = -20.788 +- 0.199 uTm^2 16:44:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:44:26 Integrated Voltage Measurement... 16:44:35 Voltage Offset Correction: v_off_ini = 692.261 uV, v_off_fin = 705.295 uV 16:44:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -68.022 uVs 16:44:35 Integrated Voltage Measurement... 16:44:44 Voltage Offset Correction: v_off_ini = 709.080 uV, v_off_fin = 707.129 uV 16:44:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.342 uVs 16:44:44 Integrated Voltage Measurement... 16:44:53 Voltage Offset Correction: v_off_ini = 698.029 uV, v_off_fin = 678.625 uV 16:44:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.152 uVs 16:44:53 Integrated Voltage Measurement... 16:45:02 Voltage Offset Correction: v_off_ini = 688.828 uV, v_off_fin = 696.423 uV 16:45:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.510 uVs 16:45:02 Integrated Voltage Measurement... 16:45:11 Voltage Offset Correction: v_off_ini = 689.638 uV, v_off_fin = 710.607 uV 16:45:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.747 uVs 16:45:11 Integrated Voltage Measurement... 16:45:20 Voltage Offset Correction: v_off_ini = 698.137 uV, v_off_fin = 704.831 uV 16:45:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.241 uVs 16:45:24 I1X Average and RMS of Measurements VT = -67.336 +- 9.043 uVs I1X = 13.467 +- 1.808 uTm 16:45:27 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:45:31 Integrated Voltage Measurement... 16:45:40 Voltage Offset Correction: v_off_ini = 701.052 uV, v_off_fin = 692.678 uV 16:45:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.403 uVs 16:45:40 Integrated Voltage Measurement... 16:45:49 Voltage Offset Correction: v_off_ini = 687.649 uV, v_off_fin = 706.841 uV 16:45:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.039 uVs 16:45:49 Integrated Voltage Measurement... 16:45:58 Voltage Offset Correction: v_off_ini = 712.928 uV, v_off_fin = 699.779 uV 16:45:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.529 uVs 16:45:58 Integrated Voltage Measurement... 16:46:07 Voltage Offset Correction: v_off_ini = 684.966 uV, v_off_fin = 687.996 uV 16:46:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.083 uVs 16:46:07 Integrated Voltage Measurement... 16:46:16 Voltage Offset Correction: v_off_ini = 679.069 uV, v_off_fin = 665.509 uV 16:46:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.056 uVs 16:46:16 Integrated Voltage Measurement... 16:46:25 Voltage Offset Correction: v_off_ini = 703.170 uV, v_off_fin = 713.765 uV 16:46:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 171.237 uVs 16:46:29 I1Y Average and RMS of Measurements VT = -176.225 +- 4.148 uVs I1Y = -35.243 +- 0.829 uTm 16:46:32 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:46:34 Integrated Voltage Measurement... 16:46:43 Voltage Offset Correction: v_off_ini = 687.681 uV, v_off_fin = 697.333 uV 16:46:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.790 uVs 16:46:43 Integrated Voltage Measurement... 16:46:52 Voltage Offset Correction: v_off_ini = 688.533 uV, v_off_fin = 689.858 uV 16:46:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.587 uVs 16:46:52 Integrated Voltage Measurement... 16:47:01 Voltage Offset Correction: v_off_ini = 681.576 uV, v_off_fin = 694.921 uV 16:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.034 uVs 16:47:01 Integrated Voltage Measurement... 16:47:10 Voltage Offset Correction: v_off_ini = 695.794 uV, v_off_fin = 704.335 uV 16:47:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.376 uVs 16:47:10 Integrated Voltage Measurement... 16:47:19 Voltage Offset Correction: v_off_ini = 689.233 uV, v_off_fin = 684.142 uV 16:47:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.377 uVs 16:47:20 Integrated Voltage Measurement... 16:47:28 Voltage Offset Correction: v_off_ini = 676.788 uV, v_off_fin = 685.534 uV 16:47:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.940 uVs 16:47:31 I2X Average and RMS of Measurements VT = -93.184 +- 6.170 uVs I2X = 8.573 +- 0.568 uTm^2 16:47:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:47:36 Integrated Voltage Measurement... 16:47:45 Voltage Offset Correction: v_off_ini = 670.075 uV, v_off_fin = 686.075 uV 16:47:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.552 uVs 16:47:45 Integrated Voltage Measurement... 16:47:54 Voltage Offset Correction: v_off_ini = 678.832 uV, v_off_fin = 684.971 uV 16:47:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.068 uVs 16:47:54 Integrated Voltage Measurement... 16:48:03 Voltage Offset Correction: v_off_ini = 697.536 uV, v_off_fin = 709.195 uV 16:48:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.678 uVs 16:48:03 Integrated Voltage Measurement... 16:48:12 Voltage Offset Correction: v_off_ini = 698.410 uV, v_off_fin = 699.218 uV 16:48:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.797 uVs 16:48:12 Integrated Voltage Measurement... 16:48:21 Voltage Offset Correction: v_off_ini = 702.785 uV, v_off_fin = 685.709 uV 16:48:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.875 uVs 16:48:21 Integrated Voltage Measurement... 16:48:30 Voltage Offset Correction: v_off_ini = 669.967 uV, v_off_fin = 686.639 uV 16:48:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.853 uVs 16:48:33 I2Y Average and RMS of Measurements VT = -231.637 +- 7.842 uVs I2Y = -21.311 +- 0.721 uTm^2 16:48:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:48:53 Integrated Voltage Measurement... 16:49:02 Voltage Offset Correction: v_off_ini = 701.254 uV, v_off_fin = 684.649 uV 16:49:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.231 uVs 16:49:02 Integrated Voltage Measurement... 16:49:11 Voltage Offset Correction: v_off_ini = 702.764 uV, v_off_fin = 679.617 uV 16:49:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.609 uVs 16:49:11 Integrated Voltage Measurement... 16:49:20 Voltage Offset Correction: v_off_ini = 685.461 uV, v_off_fin = 683.025 uV 16:49:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.522 uVs 16:49:20 Integrated Voltage Measurement... 16:49:29 Voltage Offset Correction: v_off_ini = 684.143 uV, v_off_fin = 657.645 uV 16:49:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.580 uVs 16:49:29 Integrated Voltage Measurement... 16:49:38 Voltage Offset Correction: v_off_ini = 665.803 uV, v_off_fin = 656.778 uV 16:49:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.050 uVs 16:49:38 Integrated Voltage Measurement... 16:49:47 Voltage Offset Correction: v_off_ini = 682.304 uV, v_off_fin = 673.545 uV 16:49:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.921 uVs 16:49:51 I1X Average and RMS of Measurements VT = -99.986 +- 1.774 uVs I1X = 19.998 +- 0.355 uTm 16:49:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:49:58 Integrated Voltage Measurement... 16:50:07 Voltage Offset Correction: v_off_ini = 663.505 uV, v_off_fin = 652.767 uV 16:50:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.313 uVs 16:50:07 Integrated Voltage Measurement... 16:50:16 Voltage Offset Correction: v_off_ini = 667.975 uV, v_off_fin = 655.986 uV 16:50:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.626 uVs 16:50:16 Integrated Voltage Measurement... 16:50:25 Voltage Offset Correction: v_off_ini = 658.924 uV, v_off_fin = 649.461 uV 16:50:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.746 uVs 16:50:25 Integrated Voltage Measurement... 16:50:34 Voltage Offset Correction: v_off_ini = 652.614 uV, v_off_fin = 659.013 uV 16:50:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.311 uVs 16:50:34 Integrated Voltage Measurement... 16:50:43 Voltage Offset Correction: v_off_ini = 669.771 uV, v_off_fin = 648.513 uV 16:50:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.306 uVs 16:50:43 Integrated Voltage Measurement... 16:50:52 Voltage Offset Correction: v_off_ini = 662.298 uV, v_off_fin = 669.831 uV 16:50:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.368 uVs 16:50:56 I1Y Average and RMS of Measurements VT = -182.445 +- 2.482 uVs I1Y = -36.489 +- 0.496 uTm 16:51:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:51:04 Integrated Voltage Measurement... 16:51:13 Voltage Offset Correction: v_off_ini = 651.182 uV, v_off_fin = 646.502 uV 16:51:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.746 uVs 16:51:13 Integrated Voltage Measurement... 16:51:22 Voltage Offset Correction: v_off_ini = 651.996 uV, v_off_fin = 657.169 uV 16:51:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.019 uVs 16:51:22 Integrated Voltage Measurement... 16:51:31 Voltage Offset Correction: v_off_ini = 667.457 uV, v_off_fin = 654.593 uV 16:51:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.876 uVs 16:51:31 Integrated Voltage Measurement... 16:51:40 Voltage Offset Correction: v_off_ini = 663.831 uV, v_off_fin = 675.672 uV 16:51:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.419 uVs 16:51:40 Integrated Voltage Measurement... 16:51:49 Voltage Offset Correction: v_off_ini = 664.219 uV, v_off_fin = 641.873 uV 16:51:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.180 uVs 16:51:49 Integrated Voltage Measurement... 16:51:58 Voltage Offset Correction: v_off_ini = 642.429 uV, v_off_fin = 662.118 uV 16:51:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.036 uVs 16:52:01 I2X Average and RMS of Measurements VT = -131.046 +- 1.774 uVs I2X = 12.056 +- 0.163 uTm^2 16:52:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:52:08 Integrated Voltage Measurement... 16:52:17 Voltage Offset Correction: v_off_ini = 656.557 uV, v_off_fin = 658.678 uV 16:52:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.988 uVs 16:52:17 Integrated Voltage Measurement... 16:52:26 Voltage Offset Correction: v_off_ini = 648.196 uV, v_off_fin = 651.831 uV 16:52:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.828 uVs 16:52:27 Integrated Voltage Measurement... 16:52:36 Voltage Offset Correction: v_off_ini = 656.870 uV, v_off_fin = 648.293 uV 16:52:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.470 uVs 16:52:36 Integrated Voltage Measurement... 16:52:45 Voltage Offset Correction: v_off_ini = 653.645 uV, v_off_fin = 669.490 uV 16:52:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.365 uVs 16:52:45 Integrated Voltage Measurement... 16:52:54 Voltage Offset Correction: v_off_ini = 650.688 uV, v_off_fin = 649.271 uV 16:52:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.767 uVs 16:52:54 Integrated Voltage Measurement... 16:53:03 Voltage Offset Correction: v_off_ini = 633.980 uV, v_off_fin = 625.880 uV 16:53:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.056 uVs 16:53:05 I2Y Average and RMS of Measurements VT = -233.412 +- 1.871 uVs I2Y = -21.474 +- 0.172 uTm^2 16:53:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:53:14 Integrated Voltage Measurement... 16:53:23 Voltage Offset Correction: v_off_ini = 632.402 uV, v_off_fin = 641.440 uV 16:53:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.191 uVs 16:53:23 Integrated Voltage Measurement... 16:53:32 Voltage Offset Correction: v_off_ini = 637.391 uV, v_off_fin = 624.265 uV 16:53:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.234 uVs 16:53:32 Integrated Voltage Measurement... 16:53:41 Voltage Offset Correction: v_off_ini = 612.232 uV, v_off_fin = 634.861 uV 16:53:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.224 uVs 16:53:41 Integrated Voltage Measurement... 16:53:50 Voltage Offset Correction: v_off_ini = 623.731 uV, v_off_fin = 632.715 uV 16:53:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.312 uVs 16:53:50 Integrated Voltage Measurement... 16:53:59 Voltage Offset Correction: v_off_ini = 657.901 uV, v_off_fin = 655.371 uV 16:53:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.184 uVs 16:53:59 Integrated Voltage Measurement... 16:54:08 Voltage Offset Correction: v_off_ini = 648.405 uV, v_off_fin = 652.362 uV 16:54:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.754 uVs 16:54:12 I1X Average and RMS of Measurements VT = -97.317 +- 7.898 uVs I1X = 19.464 +- 1.579 uTm 16:54:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:54:19 Integrated Voltage Measurement... 16:54:28 Voltage Offset Correction: v_off_ini = 650.372 uV, v_off_fin = 641.715 uV 16:54:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.636 uVs 16:54:28 Integrated Voltage Measurement... 16:54:37 Voltage Offset Correction: v_off_ini = 648.306 uV, v_off_fin = 652.661 uV 16:54:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.132 uVs 16:54:37 Integrated Voltage Measurement... 16:54:46 Voltage Offset Correction: v_off_ini = 649.062 uV, v_off_fin = 636.188 uV 16:54:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.095 uVs 16:54:46 Integrated Voltage Measurement... 16:54:55 Voltage Offset Correction: v_off_ini = 660.335 uV, v_off_fin = 677.708 uV 16:54:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.598 uVs 16:54:55 Integrated Voltage Measurement... 16:55:04 Voltage Offset Correction: v_off_ini = 679.648 uV, v_off_fin = 682.802 uV 16:55:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.525 uVs 16:55:04 Integrated Voltage Measurement... 16:55:13 Voltage Offset Correction: v_off_ini = 674.806 uV, v_off_fin = 676.445 uV 16:55:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.115 uVs 16:55:17 I1Y Average and RMS of Measurements VT = -192.184 +- 8.376 uVs I1Y = -38.437 +- 1.675 uTm 16:55:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:55:25 Integrated Voltage Measurement... 16:55:34 Voltage Offset Correction: v_off_ini = 671.274 uV, v_off_fin = 680.853 uV 16:55:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.652 uVs 16:55:34 Integrated Voltage Measurement... 16:55:43 Voltage Offset Correction: v_off_ini = 690.746 uV, v_off_fin = 676.183 uV 16:55:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.473 uVs 16:55:43 Integrated Voltage Measurement... 16:55:52 Voltage Offset Correction: v_off_ini = 668.819 uV, v_off_fin = 660.328 uV 16:55:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.599 uVs 16:55:52 Integrated Voltage Measurement... 16:56:01 Voltage Offset Correction: v_off_ini = 660.057 uV, v_off_fin = 660.202 uV 16:56:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.907 uVs 16:56:01 Integrated Voltage Measurement... 16:56:10 Voltage Offset Correction: v_off_ini = 678.535 uV, v_off_fin = 685.144 uV 16:56:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.974 uVs 16:56:10 Integrated Voltage Measurement... 16:56:19 Voltage Offset Correction: v_off_ini = 688.512 uV, v_off_fin = 694.036 uV 16:56:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.960 uVs 16:56:22 I2X Average and RMS of Measurements VT = -114.094 +- 4.877 uVs I2X = 10.497 +- 0.449 uTm^2 16:56:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:56:29 Integrated Voltage Measurement... 16:56:38 Voltage Offset Correction: v_off_ini = 694.787 uV, v_off_fin = 678.522 uV 16:56:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.499 uVs 16:56:38 Integrated Voltage Measurement... 16:56:47 Voltage Offset Correction: v_off_ini = 676.093 uV, v_off_fin = 664.667 uV 16:56:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.275 uVs 16:56:47 Integrated Voltage Measurement... 16:56:56 Voltage Offset Correction: v_off_ini = 685.283 uV, v_off_fin = 680.107 uV 16:56:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.887 uVs 16:56:57 Integrated Voltage Measurement... 16:57:06 Voltage Offset Correction: v_off_ini = 689.203 uV, v_off_fin = 697.307 uV 16:57:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.201 uVs 16:57:06 Integrated Voltage Measurement... 16:57:15 Voltage Offset Correction: v_off_ini = 685.417 uV, v_off_fin = 674.500 uV 16:57:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.332 uVs 16:57:15 Integrated Voltage Measurement... 16:57:24 Voltage Offset Correction: v_off_ini = 660.397 uV, v_off_fin = 673.379 uV 16:57:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.839 uVs 16:57:26 I2Y Average and RMS of Measurements VT = -237.672 +- 5.547 uVs I2Y = -21.866 +- 0.510 uTm^2 16:57:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:35 Integrated Voltage Measurement... 16:57:44 Voltage Offset Correction: v_off_ini = 677.318 uV, v_off_fin = 689.333 uV 16:57:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -90.832 uVs 16:57:44 Integrated Voltage Measurement... 16:57:53 Voltage Offset Correction: v_off_ini = 675.458 uV, v_off_fin = 669.940 uV 16:57:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.836 uVs 16:57:53 Integrated Voltage Measurement... 16:58:02 Voltage Offset Correction: v_off_ini = 676.736 uV, v_off_fin = 673.657 uV 16:58:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.673 uVs 16:58:02 Integrated Voltage Measurement... 16:58:11 Voltage Offset Correction: v_off_ini = 668.587 uV, v_off_fin = 666.785 uV 16:58:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.118 uVs 16:58:11 Integrated Voltage Measurement... 16:58:20 Voltage Offset Correction: v_off_ini = 676.327 uV, v_off_fin = 670.118 uV 16:58:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.819 uVs 16:58:20 Integrated Voltage Measurement... 16:58:29 Voltage Offset Correction: v_off_ini = 658.685 uV, v_off_fin = 666.423 uV 16:58:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.869 uVs 16:58:33 I1X Average and RMS of Measurements VT = -90.858 +- 4.406 uVs I1X = 18.172 +- 0.882 uTm 16:58:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:40 Integrated Voltage Measurement... 16:58:49 Voltage Offset Correction: v_off_ini = 671.327 uV, v_off_fin = 654.687 uV 16:58:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.772 uVs 16:58:49 Integrated Voltage Measurement... 16:58:58 Voltage Offset Correction: v_off_ini = 674.578 uV, v_off_fin = 672.772 uV 16:58:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.455 uVs 16:58:58 Integrated Voltage Measurement... 16:59:07 Voltage Offset Correction: v_off_ini = 654.471 uV, v_off_fin = 655.241 uV 16:59:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.386 uVs 16:59:07 Integrated Voltage Measurement... 16:59:16 Voltage Offset Correction: v_off_ini = 656.696 uV, v_off_fin = 660.303 uV 16:59:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.140 uVs 16:59:16 Integrated Voltage Measurement... 16:59:25 Voltage Offset Correction: v_off_ini = 654.882 uV, v_off_fin = 655.060 uV 16:59:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.227 uVs 16:59:25 Integrated Voltage Measurement... 16:59:34 Voltage Offset Correction: v_off_ini = 659.050 uV, v_off_fin = 664.518 uV 16:59:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.165 uVs 16:59:38 I1Y Average and RMS of Measurements VT = -184.024 +- 3.943 uVs I1Y = -36.805 +- 0.789 uTm 16:59:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:46 Integrated Voltage Measurement... 16:59:55 Voltage Offset Correction: v_off_ini = 649.991 uV, v_off_fin = 651.101 uV 16:59:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.877 uVs 16:59:55 Integrated Voltage Measurement... 17:00:04 Voltage Offset Correction: v_off_ini = 658.358 uV, v_off_fin = 663.284 uV 17:00:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.000 uVs 17:00:04 Integrated Voltage Measurement... 17:00:13 Voltage Offset Correction: v_off_ini = 658.836 uV, v_off_fin = 652.041 uV 17:00:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.272 uVs 17:00:13 Integrated Voltage Measurement... 17:00:22 Voltage Offset Correction: v_off_ini = 648.969 uV, v_off_fin = 654.395 uV 17:00:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.563 uVs 17:00:22 Integrated Voltage Measurement... 17:00:31 Voltage Offset Correction: v_off_ini = 652.311 uV, v_off_fin = 635.405 uV 17:00:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.947 uVs 17:00:31 Integrated Voltage Measurement... 17:00:40 Voltage Offset Correction: v_off_ini = 649.356 uV, v_off_fin = 646.561 uV 17:00:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.259 uVs 17:00:43 I2X Average and RMS of Measurements VT = -113.820 +- 5.987 uVs I2X = 10.471 +- 0.551 uTm^2 17:00:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:00:50 Integrated Voltage Measurement... 17:00:59 Voltage Offset Correction: v_off_ini = 651.317 uV, v_off_fin = 646.208 uV 17:00:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.454 uVs 17:00:59 Integrated Voltage Measurement... 17:01:08 Voltage Offset Correction: v_off_ini = 657.188 uV, v_off_fin = 653.646 uV 17:01:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.633 uVs 17:01:08 Integrated Voltage Measurement... 17:01:17 Voltage Offset Correction: v_off_ini = 655.153 uV, v_off_fin = 642.066 uV 17:01:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.820 uVs 17:01:17 Integrated Voltage Measurement... 17:01:26 Voltage Offset Correction: v_off_ini = 654.747 uV, v_off_fin = 665.803 uV 17:01:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.659 uVs 17:01:27 Integrated Voltage Measurement... 17:01:35 Voltage Offset Correction: v_off_ini = 665.768 uV, v_off_fin = 657.183 uV 17:01:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.796 uVs 17:01:36 Integrated Voltage Measurement... 17:01:45 Voltage Offset Correction: v_off_ini = 651.832 uV, v_off_fin = 660.232 uV 17:01:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.808 uVs 17:01:47 I2Y Average and RMS of Measurements VT = -232.862 +- 6.815 uVs I2Y = -21.423 +- 0.627 uTm^2 17:01:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:01:56 Integrated Voltage Measurement... 17:02:05 Voltage Offset Correction: v_off_ini = 644.897 uV, v_off_fin = 646.061 uV 17:02:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.576 uVs 17:02:05 Integrated Voltage Measurement... 17:02:14 Voltage Offset Correction: v_off_ini = 642.298 uV, v_off_fin = 646.068 uV 17:02:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.288 uVs 17:02:14 Integrated Voltage Measurement... 17:02:23 Voltage Offset Correction: v_off_ini = 658.749 uV, v_off_fin = 660.921 uV 17:02:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.783 uVs 17:02:23 Integrated Voltage Measurement... 17:02:32 Voltage Offset Correction: v_off_ini = 653.839 uV, v_off_fin = 643.862 uV 17:02:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.571 uVs 17:02:32 Integrated Voltage Measurement... 17:02:41 Voltage Offset Correction: v_off_ini = 643.632 uV, v_off_fin = 656.740 uV 17:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.176 uVs 17:02:41 Integrated Voltage Measurement... 17:02:50 Voltage Offset Correction: v_off_ini = 651.369 uV, v_off_fin = 649.974 uV 17:02:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.734 uVs 17:02:54 I1X Average and RMS of Measurements VT = -90.521 +- 2.784 uVs I1X = 18.104 +- 0.557 uTm 17:02:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:03:01 Integrated Voltage Measurement... 17:03:10 Voltage Offset Correction: v_off_ini = 646.386 uV, v_off_fin = 618.058 uV 17:03:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.665 uVs 17:03:10 Integrated Voltage Measurement... 17:03:19 Voltage Offset Correction: v_off_ini = 625.302 uV, v_off_fin = 639.141 uV 17:03:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.509 uVs 17:03:19 Integrated Voltage Measurement... 17:03:28 Voltage Offset Correction: v_off_ini = 624.452 uV, v_off_fin = 624.254 uV 17:03:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.796 uVs 17:03:28 Integrated Voltage Measurement... 17:03:37 Voltage Offset Correction: v_off_ini = 642.197 uV, v_off_fin = 650.357 uV 17:03:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.897 uVs 17:03:37 Integrated Voltage Measurement... 17:03:46 Voltage Offset Correction: v_off_ini = 623.074 uV, v_off_fin = 630.083 uV 17:03:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.114 uVs 17:03:46 Integrated Voltage Measurement... 17:03:55 Voltage Offset Correction: v_off_ini = 637.809 uV, v_off_fin = 653.875 uV 17:03:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.313 uVs 17:03:59 I1Y Average and RMS of Measurements VT = -190.716 +- 7.580 uVs I1Y = -38.143 +- 1.516 uTm 17:04:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:04:07 Integrated Voltage Measurement... 17:04:16 Voltage Offset Correction: v_off_ini = 627.332 uV, v_off_fin = 628.100 uV 17:04:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.068 uVs 17:04:16 Integrated Voltage Measurement... 17:04:25 Voltage Offset Correction: v_off_ini = 641.248 uV, v_off_fin = 631.669 uV 17:04:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.143 uVs 17:04:25 Integrated Voltage Measurement... 17:04:34 Voltage Offset Correction: v_off_ini = 638.452 uV, v_off_fin = 622.153 uV 17:04:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.335 uVs 17:04:34 Integrated Voltage Measurement... 17:04:43 Voltage Offset Correction: v_off_ini = 633.023 uV, v_off_fin = 630.110 uV 17:04:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.828 uVs 17:04:43 Integrated Voltage Measurement... 17:04:52 Voltage Offset Correction: v_off_ini = 632.871 uV, v_off_fin = 635.483 uV 17:04:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.251 uVs 17:04:52 Integrated Voltage Measurement... 17:05:01 Voltage Offset Correction: v_off_ini = 628.656 uV, v_off_fin = 629.733 uV 17:05:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.872 uVs 17:05:03 I2X Average and RMS of Measurements VT = -102.416 +- 4.103 uVs I2X = 9.422 +- 0.378 uTm^2 17:05:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:05:11 Integrated Voltage Measurement... 17:05:20 Voltage Offset Correction: v_off_ini = 623.392 uV, v_off_fin = 609.908 uV 17:05:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.029 uVs 17:05:20 Integrated Voltage Measurement... 17:05:29 Voltage Offset Correction: v_off_ini = 610.028 uV, v_off_fin = 625.541 uV 17:05:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.816 uVs 17:05:29 Integrated Voltage Measurement... 17:05:38 Voltage Offset Correction: v_off_ini = 611.318 uV, v_off_fin = 619.843 uV 17:05:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.705 uVs 17:05:38 Integrated Voltage Measurement... 17:05:47 Voltage Offset Correction: v_off_ini = 606.959 uV, v_off_fin = 615.762 uV 17:05:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.508 uVs 17:05:47 Integrated Voltage Measurement... 17:05:56 Voltage Offset Correction: v_off_ini = 602.015 uV, v_off_fin = 610.000 uV 17:05:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.968 uVs 17:05:56 Integrated Voltage Measurement... 17:06:05 Voltage Offset Correction: v_off_ini = 599.156 uV, v_off_fin = 614.872 uV 17:06:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.038 uVs 17:06:08 I2Y Average and RMS of Measurements VT = -236.177 +- 1.871 uVs I2Y = -21.728 +- 0.172 uTm^2 17:06:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:06:17 Integrated Voltage Measurement... 17:06:26 Voltage Offset Correction: v_off_ini = 614.621 uV, v_off_fin = 612.883 uV 17:06:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.996 uVs 17:06:26 Integrated Voltage Measurement... 17:06:35 Voltage Offset Correction: v_off_ini = 619.280 uV, v_off_fin = 609.231 uV 17:06:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.601 uVs 17:06:35 Integrated Voltage Measurement... 17:06:44 Voltage Offset Correction: v_off_ini = 620.236 uV, v_off_fin = 597.212 uV 17:06:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.506 uVs 17:06:44 Integrated Voltage Measurement... 17:06:53 Voltage Offset Correction: v_off_ini = 604.237 uV, v_off_fin = 605.952 uV 17:06:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.052 uVs 17:06:53 Integrated Voltage Measurement... 17:07:02 Voltage Offset Correction: v_off_ini = 586.369 uV, v_off_fin = 589.620 uV 17:07:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.342 uVs 17:07:02 Integrated Voltage Measurement... 17:07:11 Voltage Offset Correction: v_off_ini = 604.522 uV, v_off_fin = 595.137 uV 17:07:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.213 uVs 17:07:15 I1X Average and RMS of Measurements VT = -69.285 +- 2.855 uVs I1X = 13.857 +- 0.571 uTm 17:07:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:07:22 Integrated Voltage Measurement... 17:07:31 Voltage Offset Correction: v_off_ini = 593.138 uV, v_off_fin = 592.186 uV 17:07:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.803 uVs 17:07:31 Integrated Voltage Measurement... 17:07:40 Voltage Offset Correction: v_off_ini = 598.012 uV, v_off_fin = 613.139 uV 17:07:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.800 uVs 17:07:40 Integrated Voltage Measurement... 17:07:49 Voltage Offset Correction: v_off_ini = 625.322 uV, v_off_fin = 603.504 uV 17:07:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.868 uVs 17:07:49 Integrated Voltage Measurement... 17:07:58 Voltage Offset Correction: v_off_ini = 600.556 uV, v_off_fin = 617.125 uV 17:07:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.001 uVs 17:07:58 Integrated Voltage Measurement... 17:08:07 Voltage Offset Correction: v_off_ini = 601.316 uV, v_off_fin = 594.693 uV 17:08:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.718 uVs 17:08:07 Integrated Voltage Measurement... 17:08:16 Voltage Offset Correction: v_off_ini = 596.147 uV, v_off_fin = 607.882 uV 17:08:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.546 uVs 17:08:20 I1Y Average and RMS of Measurements VT = -191.623 +- 2.408 uVs I1Y = -38.325 +- 0.482 uTm 17:08:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:08:28 Integrated Voltage Measurement... 17:08:37 Voltage Offset Correction: v_off_ini = 577.949 uV, v_off_fin = 593.585 uV 17:08:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.532 uVs 17:08:37 Integrated Voltage Measurement... 17:08:46 Voltage Offset Correction: v_off_ini = 586.492 uV, v_off_fin = 586.789 uV 17:08:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.774 uVs 17:08:46 Integrated Voltage Measurement... 17:08:55 Voltage Offset Correction: v_off_ini = 582.133 uV, v_off_fin = 586.325 uV 17:08:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.567 uVs 17:08:55 Integrated Voltage Measurement... 17:09:04 Voltage Offset Correction: v_off_ini = 588.785 uV, v_off_fin = 596.047 uV 17:09:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.168 uVs 17:09:04 Integrated Voltage Measurement... 17:09:13 Voltage Offset Correction: v_off_ini = 609.103 uV, v_off_fin = 591.955 uV 17:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.034 uVs 17:09:13 Integrated Voltage Measurement... 17:09:22 Voltage Offset Correction: v_off_ini = 601.114 uV, v_off_fin = 625.263 uV 17:09:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.056 uVs 17:09:25 I2X Average and RMS of Measurements VT = -95.688 +- 3.398 uVs I2X = 8.803 +- 0.313 uTm^2 17:09:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:09:32 Integrated Voltage Measurement... 17:09:41 Voltage Offset Correction: v_off_ini = 580.370 uV, v_off_fin = 573.051 uV 17:09:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.093 uVs 17:09:41 Integrated Voltage Measurement... 17:09:50 Voltage Offset Correction: v_off_ini = 596.716 uV, v_off_fin = 589.186 uV 17:09:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.205 uVs 17:09:50 Integrated Voltage Measurement... 17:09:59 Voltage Offset Correction: v_off_ini = 595.997 uV, v_off_fin = 597.233 uV 17:09:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.243 uVs 17:09:59 Integrated Voltage Measurement... 17:10:08 Voltage Offset Correction: v_off_ini = 588.992 uV, v_off_fin = 605.884 uV 17:10:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.257 uVs 17:10:08 Integrated Voltage Measurement... 17:10:17 Voltage Offset Correction: v_off_ini = 602.860 uV, v_off_fin = 596.167 uV 17:10:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.256 uVs 17:10:17 Integrated Voltage Measurement... 17:10:26 Voltage Offset Correction: v_off_ini = 576.910 uV, v_off_fin = 571.834 uV 17:10:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.145 uVs 17:10:29 I2Y Average and RMS of Measurements VT = -237.367 +- 4.230 uVs I2Y = -21.838 +- 0.389 uTm^2 17:10:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:10:41 Integrated Voltage Measurement... 17:10:50 Voltage Offset Correction: v_off_ini = 599.671 uV, v_off_fin = 593.799 uV 17:10:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.009 uVs 17:10:50 Integrated Voltage Measurement... 17:10:59 Voltage Offset Correction: v_off_ini = 579.259 uV, v_off_fin = 595.447 uV 17:10:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.235 uVs 17:10:59 Integrated Voltage Measurement... 17:11:08 Voltage Offset Correction: v_off_ini = 604.206 uV, v_off_fin = 584.680 uV 17:11:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.775 uVs 17:11:08 Integrated Voltage Measurement... 17:11:17 Voltage Offset Correction: v_off_ini = 607.073 uV, v_off_fin = 608.127 uV 17:11:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.146 uVs 17:11:17 Integrated Voltage Measurement... 17:11:26 Voltage Offset Correction: v_off_ini = 581.190 uV, v_off_fin = 581.048 uV 17:11:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.638 uVs 17:11:26 Integrated Voltage Measurement... 17:11:35 Voltage Offset Correction: v_off_ini = 591.507 uV, v_off_fin = 587.089 uV 17:11:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.904 uVs 17:11:39 I1X Average and RMS of Measurements VT = -87.618 +- 10.853 uVs I1X = 17.524 +- 2.171 uTm 17:11:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:11:46 Integrated Voltage Measurement... 17:11:55 Voltage Offset Correction: v_off_ini = 605.096 uV, v_off_fin = 589.564 uV 17:11:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.936 uVs 17:11:55 Integrated Voltage Measurement... 17:12:04 Voltage Offset Correction: v_off_ini = 581.161 uV, v_off_fin = 598.181 uV 17:12:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.647 uVs 17:12:04 Integrated Voltage Measurement... 17:12:13 Voltage Offset Correction: v_off_ini = 596.934 uV, v_off_fin = 576.453 uV 17:12:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.567 uVs 17:12:13 Integrated Voltage Measurement... 17:12:22 Voltage Offset Correction: v_off_ini = 565.315 uV, v_off_fin = 584.250 uV 17:12:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.397 uVs 17:12:22 Integrated Voltage Measurement... 17:12:31 Voltage Offset Correction: v_off_ini = 587.022 uV, v_off_fin = 576.199 uV 17:12:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.492 uVs 17:12:31 Integrated Voltage Measurement... 17:12:40 Voltage Offset Correction: v_off_ini = 579.144 uV, v_off_fin = 591.152 uV 17:12:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.057 uVs 17:12:44 I1Y Average and RMS of Measurements VT = -191.349 +- 2.351 uVs I1Y = -38.270 +- 0.470 uTm 17:12:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:12:49 Integrated Voltage Measurement... 17:12:58 Voltage Offset Correction: v_off_ini = 551.363 uV, v_off_fin = 561.074 uV 17:12:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.521 uVs 17:12:58 Integrated Voltage Measurement... 17:13:07 Voltage Offset Correction: v_off_ini = 564.471 uV, v_off_fin = 574.744 uV 17:13:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.395 uVs 17:13:07 Integrated Voltage Measurement... 17:13:16 Voltage Offset Correction: v_off_ini = 576.320 uV, v_off_fin = 570.368 uV 17:13:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.546 uVs 17:13:16 Integrated Voltage Measurement... 17:13:25 Voltage Offset Correction: v_off_ini = 562.997 uV, v_off_fin = 574.094 uV 17:13:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.039 uVs 17:13:25 Integrated Voltage Measurement... 17:13:34 Voltage Offset Correction: v_off_ini = 582.336 uV, v_off_fin = 559.136 uV 17:13:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.218 uVs 17:13:34 Integrated Voltage Measurement... 17:13:43 Voltage Offset Correction: v_off_ini = 555.169 uV, v_off_fin = 581.506 uV 17:13:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.330 uVs 17:13:46 I2X Average and RMS of Measurements VT = -113.175 +- 9.489 uVs I2X = 10.412 +- 0.873 uTm^2 17:13:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:13:51 Integrated Voltage Measurement... 17:14:00 Voltage Offset Correction: v_off_ini = 568.546 uV, v_off_fin = 557.035 uV 17:14:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.401 uVs 17:14:00 Integrated Voltage Measurement... 17:14:09 Voltage Offset Correction: v_off_ini = 569.120 uV, v_off_fin = 559.722 uV 17:14:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.164 uVs 17:14:09 Integrated Voltage Measurement... 17:14:18 Voltage Offset Correction: v_off_ini = 584.891 uV, v_off_fin = 574.733 uV 17:14:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.247 uVs 17:14:18 Integrated Voltage Measurement... 17:14:27 Voltage Offset Correction: v_off_ini = 576.111 uV, v_off_fin = 576.911 uV 17:14:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.856 uVs 17:14:27 Integrated Voltage Measurement... 17:14:36 Voltage Offset Correction: v_off_ini = 563.338 uV, v_off_fin = 556.923 uV 17:14:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.184 uVs 17:14:36 Integrated Voltage Measurement... 17:14:45 Voltage Offset Correction: v_off_ini = 557.314 uV, v_off_fin = 572.419 uV 17:14:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.247 uVs 17:14:48 I2Y Average and RMS of Measurements VT = -250.016 +- 11.235 uVs I2Y = -23.002 +- 1.034 uTm^2 17:14:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:14:56 Integrated Voltage Measurement... 17:15:05 Voltage Offset Correction: v_off_ini = 580.753 uV, v_off_fin = 561.114 uV 17:15:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.204 uVs 17:15:05 Integrated Voltage Measurement... 17:15:14 Voltage Offset Correction: v_off_ini = 569.592 uV, v_off_fin = 558.768 uV 17:15:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.147 uVs 17:15:14 Integrated Voltage Measurement... 17:15:23 Voltage Offset Correction: v_off_ini = 561.114 uV, v_off_fin = 574.479 uV 17:15:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.982 uVs 17:15:23 Integrated Voltage Measurement... 17:15:32 Voltage Offset Correction: v_off_ini = 553.059 uV, v_off_fin = 565.738 uV 17:15:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.210 uVs 17:15:32 Integrated Voltage Measurement... 17:15:41 Voltage Offset Correction: v_off_ini = 566.524 uV, v_off_fin = 565.889 uV 17:15:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.139 uVs 17:15:41 Integrated Voltage Measurement... 17:15:50 Voltage Offset Correction: v_off_ini = 543.584 uV, v_off_fin = 559.480 uV 17:15:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.359 uVs 17:15:54 I1X Average and RMS of Measurements VT = -91.840 +- 11.319 uVs I1X = 18.368 +- 2.264 uTm 17:15:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:16:01 Integrated Voltage Measurement... 17:16:10 Voltage Offset Correction: v_off_ini = 544.104 uV, v_off_fin = 550.794 uV 17:16:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.812 uVs 17:16:10 Integrated Voltage Measurement... 17:16:19 Voltage Offset Correction: v_off_ini = 555.172 uV, v_off_fin = 548.522 uV 17:16:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.764 uVs 17:16:19 Integrated Voltage Measurement... 17:16:28 Voltage Offset Correction: v_off_ini = 552.847 uV, v_off_fin = 549.045 uV 17:16:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.227 uVs 17:16:28 Integrated Voltage Measurement... 17:16:37 Voltage Offset Correction: v_off_ini = 561.126 uV, v_off_fin = 562.547 uV 17:16:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.078 uVs 17:16:37 Integrated Voltage Measurement... 17:16:46 Voltage Offset Correction: v_off_ini = 562.221 uV, v_off_fin = 563.014 uV 17:16:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.064 uVs 17:16:46 Integrated Voltage Measurement... 17:16:55 Voltage Offset Correction: v_off_ini = 574.422 uV, v_off_fin = 581.142 uV 17:16:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.495 uVs 17:16:59 I1Y Average and RMS of Measurements VT = -188.907 +- 10.849 uVs I1Y = -37.781 +- 2.170 uTm 17:17:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:17:04 Integrated Voltage Measurement... 17:17:13 Voltage Offset Correction: v_off_ini = 556.877 uV, v_off_fin = 549.940 uV 17:17:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.032 uVs 17:17:13 Integrated Voltage Measurement... 17:17:22 Voltage Offset Correction: v_off_ini = 565.017 uV, v_off_fin = 566.888 uV 17:17:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.986 uVs 17:17:22 Integrated Voltage Measurement... 17:17:31 Voltage Offset Correction: v_off_ini = 559.535 uV, v_off_fin = 564.452 uV 17:17:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.151 uVs 17:17:31 Integrated Voltage Measurement... 17:17:40 Voltage Offset Correction: v_off_ini = 572.799 uV, v_off_fin = 567.335 uV 17:17:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.236 uVs 17:17:40 Integrated Voltage Measurement... 17:17:49 Voltage Offset Correction: v_off_ini = 565.080 uV, v_off_fin = 561.663 uV 17:17:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.797 uVs 17:17:49 Integrated Voltage Measurement... 17:17:58 Voltage Offset Correction: v_off_ini = 556.408 uV, v_off_fin = 571.554 uV 17:17:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.526 uVs 17:18:01 I2X Average and RMS of Measurements VT = -117.955 +- 7.540 uVs I2X = 10.852 +- 0.694 uTm^2 17:18:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:18:06 Integrated Voltage Measurement... 17:18:15 Voltage Offset Correction: v_off_ini = 561.693 uV, v_off_fin = 570.936 uV 17:18:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.075 uVs 17:18:15 Integrated Voltage Measurement... 17:18:24 Voltage Offset Correction: v_off_ini = 567.086 uV, v_off_fin = 565.446 uV 17:18:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.619 uVs 17:18:24 Integrated Voltage Measurement... 17:18:33 Voltage Offset Correction: v_off_ini = 566.157 uV, v_off_fin = 573.463 uV 17:18:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.665 uVs 17:18:33 Integrated Voltage Measurement... 17:18:42 Voltage Offset Correction: v_off_ini = 568.641 uV, v_off_fin = 579.590 uV 17:18:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.389 uVs 17:18:42 Integrated Voltage Measurement... 17:18:51 Voltage Offset Correction: v_off_ini = 609.486 uV, v_off_fin = 596.854 uV 17:18:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.241 uVs 17:18:51 Integrated Voltage Measurement... 17:19:00 Voltage Offset Correction: v_off_ini = 595.625 uV, v_off_fin = 597.346 uV 17:19:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.326 uVs 17:19:03 I2Y Average and RMS of Measurements VT = -247.219 +- 3.992 uVs I2Y = -22.744 +- 0.367 uTm^2 17:19:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:11 Integrated Voltage Measurement... 17:19:20 Voltage Offset Correction: v_off_ini = 599.797 uV, v_off_fin = 600.944 uV 17:19:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.823 uVs 17:19:20 Integrated Voltage Measurement... 17:19:29 Voltage Offset Correction: v_off_ini = 584.870 uV, v_off_fin = 579.538 uV 17:19:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.564 uVs 17:19:29 Integrated Voltage Measurement... 17:19:38 Voltage Offset Correction: v_off_ini = 582.083 uV, v_off_fin = 575.532 uV 17:19:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.711 uVs 17:19:38 Integrated Voltage Measurement... 17:19:47 Voltage Offset Correction: v_off_ini = 571.527 uV, v_off_fin = 581.723 uV 17:19:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.710 uVs 17:19:47 Integrated Voltage Measurement... 17:19:56 Voltage Offset Correction: v_off_ini = 576.757 uV, v_off_fin = 589.973 uV 17:19:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.278 uVs 17:19:56 Integrated Voltage Measurement... 17:20:05 Voltage Offset Correction: v_off_ini = 574.734 uV, v_off_fin = 563.122 uV 17:20:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.777 uVs 17:20:09 I1X Average and RMS of Measurements VT = -96.311 +- 2.675 uVs I1X = 19.262 +- 0.535 uTm 17:20:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:16 Integrated Voltage Measurement... 17:20:25 Voltage Offset Correction: v_off_ini = 568.577 uV, v_off_fin = 558.777 uV 17:20:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.357 uVs 17:20:25 Integrated Voltage Measurement... 17:20:34 Voltage Offset Correction: v_off_ini = 552.858 uV, v_off_fin = 557.803 uV 17:20:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.200 uVs 17:20:34 Integrated Voltage Measurement... 17:20:43 Voltage Offset Correction: v_off_ini = 549.820 uV, v_off_fin = 552.424 uV 17:20:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.065 uVs 17:20:43 Integrated Voltage Measurement... 17:20:52 Voltage Offset Correction: v_off_ini = 554.369 uV, v_off_fin = 558.260 uV 17:20:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.025 uVs 17:20:52 Integrated Voltage Measurement... 17:21:01 Voltage Offset Correction: v_off_ini = 556.830 uV, v_off_fin = 538.648 uV 17:21:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.078 uVs 17:21:01 Integrated Voltage Measurement... 17:21:10 Voltage Offset Correction: v_off_ini = 543.195 uV, v_off_fin = 564.711 uV 17:21:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.764 uVs 17:21:14 I1Y Average and RMS of Measurements VT = -184.748 +- 7.211 uVs I1Y = -36.950 +- 1.442 uTm 17:21:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:21:19 Integrated Voltage Measurement... 17:21:28 Voltage Offset Correction: v_off_ini = 541.764 uV, v_off_fin = 543.699 uV 17:21:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.306 uVs 17:21:28 Integrated Voltage Measurement... 17:21:37 Voltage Offset Correction: v_off_ini = 551.091 uV, v_off_fin = 560.016 uV 17:21:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.328 uVs 17:21:37 Integrated Voltage Measurement... 17:21:46 Voltage Offset Correction: v_off_ini = 563.292 uV, v_off_fin = 551.286 uV 17:21:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.514 uVs 17:21:46 Integrated Voltage Measurement... 17:21:55 Voltage Offset Correction: v_off_ini = 561.707 uV, v_off_fin = 567.641 uV 17:21:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.477 uVs 17:21:56 Integrated Voltage Measurement... 17:22:04 Voltage Offset Correction: v_off_ini = 562.827 uV, v_off_fin = 558.911 uV 17:22:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.519 uVs 17:22:05 Integrated Voltage Measurement... 17:22:14 Voltage Offset Correction: v_off_ini = 560.988 uV, v_off_fin = 552.381 uV 17:22:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.250 uVs 17:22:16 I2X Average and RMS of Measurements VT = -110.399 +- 4.109 uVs I2X = 10.157 +- 0.378 uTm^2 17:22:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:21 Integrated Voltage Measurement... 17:22:30 Voltage Offset Correction: v_off_ini = 567.896 uV, v_off_fin = 570.060 uV 17:22:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.233 uVs 17:22:30 Integrated Voltage Measurement... 17:22:39 Voltage Offset Correction: v_off_ini = 569.198 uV, v_off_fin = 576.037 uV 17:22:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.934 uVs 17:22:39 Integrated Voltage Measurement... 17:22:48 Voltage Offset Correction: v_off_ini = 558.899 uV, v_off_fin = 565.562 uV 17:22:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.260 uVs 17:22:48 Integrated Voltage Measurement... 17:22:57 Voltage Offset Correction: v_off_ini = 573.083 uV, v_off_fin = 579.845 uV 17:22:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.861 uVs 17:22:57 Integrated Voltage Measurement... 17:23:06 Voltage Offset Correction: v_off_ini = 562.408 uV, v_off_fin = 557.871 uV 17:23:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.825 uVs 17:23:06 Integrated Voltage Measurement... 17:23:15 Voltage Offset Correction: v_off_ini = 566.241 uV, v_off_fin = 561.800 uV 17:23:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.509 uVs 17:23:18 I2Y Average and RMS of Measurements VT = -244.437 +- 5.060 uVs I2Y = -22.488 +- 0.466 uTm^2 17:23:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:23:26 Integrated Voltage Measurement... 17:23:35 Voltage Offset Correction: v_off_ini = 547.070 uV, v_off_fin = 551.988 uV 17:23:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.739 uVs 17:23:35 Integrated Voltage Measurement... 17:23:44 Voltage Offset Correction: v_off_ini = 557.533 uV, v_off_fin = 554.831 uV 17:23:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.016 uVs 17:23:44 Integrated Voltage Measurement... 17:23:53 Voltage Offset Correction: v_off_ini = 558.141 uV, v_off_fin = 559.966 uV 17:23:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.575 uVs 17:23:53 Integrated Voltage Measurement... 17:24:02 Voltage Offset Correction: v_off_ini = 577.858 uV, v_off_fin = 561.379 uV 17:24:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.370 uVs 17:24:02 Integrated Voltage Measurement... 17:24:11 Voltage Offset Correction: v_off_ini = 580.443 uV, v_off_fin = 560.640 uV 17:24:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.612 uVs 17:24:11 Integrated Voltage Measurement... 17:24:20 Voltage Offset Correction: v_off_ini = 561.715 uV, v_off_fin = 570.382 uV 17:24:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.560 uVs 17:24:24 I1X Average and RMS of Measurements VT = -78.812 +- 6.783 uVs I1X = 15.763 +- 1.357 uTm 17:24:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:24:31 Integrated Voltage Measurement... 17:24:40 Voltage Offset Correction: v_off_ini = 559.919 uV, v_off_fin = 556.192 uV 17:24:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -181.789 uVs 17:24:40 Integrated Voltage Measurement... 17:24:49 Voltage Offset Correction: v_off_ini = 559.767 uV, v_off_fin = 585.402 uV 17:24:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.694 uVs 17:24:49 Integrated Voltage Measurement... 17:24:58 Voltage Offset Correction: v_off_ini = 586.766 uV, v_off_fin = 567.563 uV 17:24:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.680 uVs 17:24:58 Integrated Voltage Measurement... 17:25:07 Voltage Offset Correction: v_off_ini = 562.075 uV, v_off_fin = 579.690 uV 17:25:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.760 uVs 17:25:07 Integrated Voltage Measurement... 17:25:16 Voltage Offset Correction: v_off_ini = 559.484 uV, v_off_fin = 546.706 uV 17:25:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.032 uVs 17:25:16 Integrated Voltage Measurement... 17:25:25 Voltage Offset Correction: v_off_ini = 569.827 uV, v_off_fin = 583.674 uV 17:25:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.264 uVs 17:25:29 I1Y Average and RMS of Measurements VT = -187.036 +- 7.107 uVs I1Y = -37.408 +- 1.421 uTm 17:25:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:25:34 Integrated Voltage Measurement... 17:25:43 Voltage Offset Correction: v_off_ini = 558.944 uV, v_off_fin = 549.880 uV 17:25:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.894 uVs 17:25:43 Integrated Voltage Measurement... 17:25:52 Voltage Offset Correction: v_off_ini = 567.987 uV, v_off_fin = 565.505 uV 17:25:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.642 uVs 17:25:52 Integrated Voltage Measurement... 17:26:01 Voltage Offset Correction: v_off_ini = 546.401 uV, v_off_fin = 555.707 uV 17:26:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.310 uVs 17:26:01 Integrated Voltage Measurement... 17:26:10 Voltage Offset Correction: v_off_ini = 552.500 uV, v_off_fin = 552.160 uV 17:26:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.231 uVs 17:26:11 Integrated Voltage Measurement... 17:26:20 Voltage Offset Correction: v_off_ini = 532.611 uV, v_off_fin = 538.589 uV 17:26:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.367 uVs 17:26:20 Integrated Voltage Measurement... 17:26:29 Voltage Offset Correction: v_off_ini = 532.572 uV, v_off_fin = 539.466 uV 17:26:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.690 uVs 17:26:31 I2X Average and RMS of Measurements VT = -112.022 +- 13.837 uVs I2X = 10.306 +- 1.273 uTm^2 17:26:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:26:36 Integrated Voltage Measurement... 17:26:45 Voltage Offset Correction: v_off_ini = 515.541 uV, v_off_fin = 528.622 uV 17:26:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.588 uVs 17:26:45 Integrated Voltage Measurement... 17:26:54 Voltage Offset Correction: v_off_ini = 539.513 uV, v_off_fin = 545.281 uV 17:26:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.133 uVs 17:26:54 Integrated Voltage Measurement... 17:27:03 Voltage Offset Correction: v_off_ini = 529.053 uV, v_off_fin = 534.526 uV 17:27:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.865 uVs 17:27:03 Integrated Voltage Measurement... 17:27:12 Voltage Offset Correction: v_off_ini = 511.887 uV, v_off_fin = 515.971 uV 17:27:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.122 uVs 17:27:12 Integrated Voltage Measurement... 17:27:21 Voltage Offset Correction: v_off_ini = 524.860 uV, v_off_fin = 527.914 uV 17:27:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.122 uVs 17:27:21 Integrated Voltage Measurement... 17:27:30 Voltage Offset Correction: v_off_ini = 517.052 uV, v_off_fin = 535.584 uV 17:27:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.339 uVs 17:27:33 I2Y Average and RMS of Measurements VT = -233.361 +- 0.768 uVs I2Y = -21.469 +- 0.071 uTm^2 17:27:37 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:27:41 Integrated Voltage Measurement... 17:27:50 Voltage Offset Correction: v_off_ini = 526.483 uV, v_off_fin = 529.980 uV 17:27:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.300 uVs 17:27:50 Integrated Voltage Measurement... 17:27:59 Voltage Offset Correction: v_off_ini = 532.717 uV, v_off_fin = 551.034 uV 17:27:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.037 uVs 17:27:59 Integrated Voltage Measurement... 17:28:08 Voltage Offset Correction: v_off_ini = 553.245 uV, v_off_fin = 530.686 uV 17:28:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.418 uVs 17:28:08 Integrated Voltage Measurement... 17:28:17 Voltage Offset Correction: v_off_ini = 495.425 uV, v_off_fin = 511.017 uV 17:28:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.726 uVs 17:28:17 Integrated Voltage Measurement... 17:28:26 Voltage Offset Correction: v_off_ini = 491.310 uV, v_off_fin = 500.217 uV 17:28:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.963 uVs 17:28:26 Integrated Voltage Measurement... 17:28:35 Voltage Offset Correction: v_off_ini = 516.329 uV, v_off_fin = 503.135 uV 17:28:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.974 uVs 17:28:39 I1X Average and RMS of Measurements VT = -76.903 +- 3.167 uVs I1X = 15.381 +- 0.634 uTm 17:28:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:28:46 Integrated Voltage Measurement... 17:28:55 Voltage Offset Correction: v_off_ini = 486.633 uV, v_off_fin = 481.106 uV 17:28:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -159.233 uVs 17:28:55 Integrated Voltage Measurement... 17:29:04 Voltage Offset Correction: v_off_ini = 478.567 uV, v_off_fin = 498.876 uV 17:29:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.592 uVs 17:29:04 Integrated Voltage Measurement... 17:29:13 Voltage Offset Correction: v_off_ini = 500.991 uV, v_off_fin = 485.199 uV 17:29:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.389 uVs 17:29:13 Integrated Voltage Measurement... 17:29:22 Voltage Offset Correction: v_off_ini = 479.852 uV, v_off_fin = 502.893 uV 17:29:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.656 uVs 17:29:22 Integrated Voltage Measurement... 17:29:31 Voltage Offset Correction: v_off_ini = 496.240 uV, v_off_fin = 472.361 uV 17:29:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.630 uVs 17:29:31 Integrated Voltage Measurement... 17:29:40 Voltage Offset Correction: v_off_ini = 483.851 uV, v_off_fin = 502.830 uV 17:29:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.833 uVs 17:29:44 I1Y Average and RMS of Measurements VT = -176.222 +- 5.171 uVs I1Y = -35.244 +- 1.033 uTm 17:29:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:29:49 Integrated Voltage Measurement... 17:29:58 Voltage Offset Correction: v_off_ini = 483.008 uV, v_off_fin = 488.996 uV 17:29:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.130 uVs 17:29:58 Integrated Voltage Measurement... 17:30:07 Voltage Offset Correction: v_off_ini = 521.096 uV, v_off_fin = 506.178 uV 17:30:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.994 uVs 17:30:07 Integrated Voltage Measurement... 17:30:16 Voltage Offset Correction: v_off_ini = 496.183 uV, v_off_fin = 488.981 uV 17:30:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.272 uVs 17:30:16 Integrated Voltage Measurement... 17:30:25 Voltage Offset Correction: v_off_ini = 490.183 uV, v_off_fin = 517.563 uV 17:30:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.644 uVs 17:30:25 Integrated Voltage Measurement... 17:30:34 Voltage Offset Correction: v_off_ini = 496.078 uV, v_off_fin = 490.711 uV 17:30:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.552 uVs 17:30:34 Integrated Voltage Measurement... 17:30:43 Voltage Offset Correction: v_off_ini = 509.331 uV, v_off_fin = 517.305 uV 17:30:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.172 uVs 17:30:46 I2X Average and RMS of Measurements VT = -82.127 +- 4.488 uVs I2X = 7.556 +- 0.413 uTm^2 17:30:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:30:51 Integrated Voltage Measurement... 17:31:00 Voltage Offset Correction: v_off_ini = 514.623 uV, v_off_fin = 537.087 uV 17:31:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.541 uVs 17:31:00 Integrated Voltage Measurement... 17:31:09 Voltage Offset Correction: v_off_ini = 525.493 uV, v_off_fin = 527.372 uV 17:31:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.538 uVs 17:31:09 Integrated Voltage Measurement... 17:31:18 Voltage Offset Correction: v_off_ini = 511.541 uV, v_off_fin = 507.978 uV 17:31:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.068 uVs 17:31:18 Integrated Voltage Measurement... 17:31:27 Voltage Offset Correction: v_off_ini = 503.381 uV, v_off_fin = 517.800 uV 17:31:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.780 uVs 17:31:27 Integrated Voltage Measurement... 17:31:36 Voltage Offset Correction: v_off_ini = 505.724 uV, v_off_fin = 485.818 uV 17:31:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.490 uVs 17:31:36 Integrated Voltage Measurement... 17:31:45 Voltage Offset Correction: v_off_ini = 504.321 uV, v_off_fin = 503.499 uV 17:31:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.696 uVs 17:31:48 I2Y Average and RMS of Measurements VT = -231.352 +- 6.435 uVs I2Y = -21.284 +- 0.592 uTm^2 17:32:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:32:25 Integrated Voltage Measurement... 17:32:34 Voltage Offset Correction: v_off_ini = 494.398 uV, v_off_fin = 487.561 uV 17:32:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.350 uVs 17:32:34 Integrated Voltage Measurement... 17:32:43 Voltage Offset Correction: v_off_ini = 498.896 uV, v_off_fin = 490.923 uV 17:32:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.996 uVs 17:32:43 Integrated Voltage Measurement... 17:32:52 Voltage Offset Correction: v_off_ini = 498.359 uV, v_off_fin = 508.132 uV 17:32:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.718 uVs 17:32:52 Integrated Voltage Measurement... 17:33:01 Voltage Offset Correction: v_off_ini = 502.847 uV, v_off_fin = 506.975 uV 17:33:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.464 uVs 17:33:01 Integrated Voltage Measurement... 17:33:10 Voltage Offset Correction: v_off_ini = 498.265 uV, v_off_fin = 534.311 uV 17:33:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.404 uVs 17:33:10 Integrated Voltage Measurement... 17:33:19 Voltage Offset Correction: v_off_ini = 533.559 uV, v_off_fin = 540.256 uV 17:33:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.616 uVs 17:33:23 I1X Average and RMS of Measurements VT = -101.258 +- 6.154 uVs I1X = 20.252 +- 1.230 uTm 17:33:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:33:30 Integrated Voltage Measurement... 17:33:39 Voltage Offset Correction: v_off_ini = 533.863 uV, v_off_fin = 527.062 uV 17:33:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.790 uVs 17:33:39 Integrated Voltage Measurement... 17:33:48 Voltage Offset Correction: v_off_ini = 514.558 uV, v_off_fin = 536.932 uV 17:33:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.438 uVs 17:33:48 Integrated Voltage Measurement... 17:33:57 Voltage Offset Correction: v_off_ini = 529.962 uV, v_off_fin = 503.584 uV 17:33:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.208 uVs 17:33:57 Integrated Voltage Measurement... 17:34:06 Voltage Offset Correction: v_off_ini = 516.128 uV, v_off_fin = 534.748 uV 17:34:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.059 uVs 17:34:06 Integrated Voltage Measurement... 17:34:15 Voltage Offset Correction: v_off_ini = 527.811 uV, v_off_fin = 531.973 uV 17:34:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.139 uVs 17:34:15 Integrated Voltage Measurement... 17:34:24 Voltage Offset Correction: v_off_ini = 545.641 uV, v_off_fin = 566.631 uV 17:34:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.404 uVs 17:34:28 I1Y Average and RMS of Measurements VT = -206.006 +- 4.931 uVs I1Y = -41.201 +- 0.986 uTm 17:34:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:34:36 Integrated Voltage Measurement... 17:34:45 Voltage Offset Correction: v_off_ini = 558.640 uV, v_off_fin = 546.415 uV 17:34:45 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -133.147 uVs 17:34:45 Integrated Voltage Measurement... 17:34:54 Voltage Offset Correction: v_off_ini = 554.062 uV, v_off_fin = 558.023 uV 17:34:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.458 uVs 17:34:54 Integrated Voltage Measurement... 17:35:03 Voltage Offset Correction: v_off_ini = 543.320 uV, v_off_fin = 533.919 uV 17:35:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.526 uVs 17:35:03 Integrated Voltage Measurement... 17:35:12 Voltage Offset Correction: v_off_ini = 551.776 uV, v_off_fin = 564.527 uV 17:35:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.575 uVs 17:35:12 Integrated Voltage Measurement... 17:35:21 Voltage Offset Correction: v_off_ini = 532.072 uV, v_off_fin = 536.773 uV 17:35:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.865 uVs 17:35:21 Integrated Voltage Measurement... 17:35:30 Voltage Offset Correction: v_off_ini = 553.273 uV, v_off_fin = 569.456 uV 17:35:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.066 uVs 17:35:32 I2X Average and RMS of Measurements VT = -128.606 +- 5.808 uVs I2X = 11.832 +- 0.534 uTm^2 17:35:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:35:40 Integrated Voltage Measurement... 17:35:49 Voltage Offset Correction: v_off_ini = 580.457 uV, v_off_fin = 558.721 uV 17:35:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.358 uVs 17:35:49 Integrated Voltage Measurement... 17:35:58 Voltage Offset Correction: v_off_ini = 556.151 uV, v_off_fin = 561.979 uV 17:35:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.704 uVs 17:35:58 Integrated Voltage Measurement... 17:36:07 Voltage Offset Correction: v_off_ini = 549.742 uV, v_off_fin = 566.770 uV 17:36:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.832 uVs 17:36:07 Integrated Voltage Measurement... 17:36:16 Voltage Offset Correction: v_off_ini = 570.657 uV, v_off_fin = 567.634 uV 17:36:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.115 uVs 17:36:16 Integrated Voltage Measurement... 17:36:25 Voltage Offset Correction: v_off_ini = 565.022 uV, v_off_fin = 560.188 uV 17:36:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.146 uVs 17:36:25 Integrated Voltage Measurement... 17:36:34 Voltage Offset Correction: v_off_ini = 550.076 uV, v_off_fin = 548.780 uV 17:36:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.121 uVs 17:36:37 I2Y Average and RMS of Measurements VT = -236.213 +- 2.491 uVs I2Y = -21.732 +- 0.229 uTm^2 17:36:41 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:36:45 Integrated Voltage Measurement... 17:36:54 Voltage Offset Correction: v_off_ini = 580.176 uV, v_off_fin = 567.066 uV 17:36:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -121.443 uVs 17:36:54 Integrated Voltage Measurement... 17:37:03 Voltage Offset Correction: v_off_ini = 559.909 uV, v_off_fin = 561.965 uV 17:37:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.292 uVs 17:37:03 Integrated Voltage Measurement... 17:37:12 Voltage Offset Correction: v_off_ini = 537.312 uV, v_off_fin = 546.042 uV 17:37:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.802 uVs 17:37:12 Integrated Voltage Measurement... 17:37:21 Voltage Offset Correction: v_off_ini = 555.971 uV, v_off_fin = 566.092 uV 17:37:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.835 uVs 17:37:22 Integrated Voltage Measurement... 17:37:30 Voltage Offset Correction: v_off_ini = 562.845 uV, v_off_fin = 566.696 uV 17:37:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.039 uVs 17:37:30 Integrated Voltage Measurement... 17:37:39 Voltage Offset Correction: v_off_ini = 546.462 uV, v_off_fin = 546.656 uV 17:37:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.218 uVs 17:37:44 I1X Average and RMS of Measurements VT = -99.438 +- 9.411 uVs I1X = 19.888 +- 1.883 uTm 17:37:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:37:50 Integrated Voltage Measurement... 17:37:59 Voltage Offset Correction: v_off_ini = 556.309 uV, v_off_fin = 554.597 uV 17:37:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.060 uVs 17:37:59 Integrated Voltage Measurement... 17:38:08 Voltage Offset Correction: v_off_ini = 560.668 uV, v_off_fin = 573.939 uV 17:38:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.684 uVs 17:38:08 Integrated Voltage Measurement... 17:38:17 Voltage Offset Correction: v_off_ini = 580.027 uV, v_off_fin = 568.240 uV 17:38:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.679 uVs 17:38:17 Integrated Voltage Measurement... 17:38:26 Voltage Offset Correction: v_off_ini = 546.691 uV, v_off_fin = 574.766 uV 17:38:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.669 uVs 17:38:26 Integrated Voltage Measurement... 17:38:35 Voltage Offset Correction: v_off_ini = 559.166 uV, v_off_fin = 566.498 uV 17:38:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.589 uVs 17:38:35 Integrated Voltage Measurement... 17:38:44 Voltage Offset Correction: v_off_ini = 555.024 uV, v_off_fin = 551.885 uV 17:38:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.808 uVs 17:38:49 I1Y Average and RMS of Measurements VT = -215.748 +- 2.441 uVs I1Y = -43.150 +- 0.487 uTm 17:38:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:38:56 Integrated Voltage Measurement... 17:39:05 Voltage Offset Correction: v_off_ini = 563.242 uV, v_off_fin = 549.877 uV 17:39:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.627 uVs 17:39:05 Integrated Voltage Measurement... 17:39:14 Voltage Offset Correction: v_off_ini = 557.370 uV, v_off_fin = 558.004 uV 17:39:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.065 uVs 17:39:14 Integrated Voltage Measurement... 17:39:23 Voltage Offset Correction: v_off_ini = 559.742 uV, v_off_fin = 536.775 uV 17:39:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.720 uVs 17:39:23 Integrated Voltage Measurement... 17:39:32 Voltage Offset Correction: v_off_ini = 555.714 uV, v_off_fin = 552.284 uV 17:39:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.672 uVs 17:39:33 Integrated Voltage Measurement... 17:39:42 Voltage Offset Correction: v_off_ini = 558.419 uV, v_off_fin = 548.564 uV 17:39:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.821 uVs 17:39:42 Integrated Voltage Measurement... 17:39:51 Voltage Offset Correction: v_off_ini = 553.090 uV, v_off_fin = 561.983 uV 17:39:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.603 uVs 17:39:53 I2X Average and RMS of Measurements VT = -115.251 +- 7.464 uVs I2X = 10.603 +- 0.687 uTm^2 17:39:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:40:01 Integrated Voltage Measurement... 17:40:10 Voltage Offset Correction: v_off_ini = 551.950 uV, v_off_fin = 543.406 uV 17:40:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.877 uVs 17:40:10 Integrated Voltage Measurement... 17:40:19 Voltage Offset Correction: v_off_ini = 522.033 uV, v_off_fin = 538.102 uV 17:40:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.226 uVs 17:40:19 Integrated Voltage Measurement... 17:40:28 Voltage Offset Correction: v_off_ini = 529.393 uV, v_off_fin = 526.921 uV 17:40:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.638 uVs 17:40:28 Integrated Voltage Measurement... 17:40:37 Voltage Offset Correction: v_off_ini = 522.402 uV, v_off_fin = 525.921 uV 17:40:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.490 uVs 17:40:37 Integrated Voltage Measurement... 17:40:46 Voltage Offset Correction: v_off_ini = 538.574 uV, v_off_fin = 544.829 uV 17:40:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.746 uVs 17:40:46 Integrated Voltage Measurement... 17:40:55 Voltage Offset Correction: v_off_ini = 542.976 uV, v_off_fin = 548.077 uV 17:40:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.265 uVs 17:40:57 I2Y Average and RMS of Measurements VT = -237.707 +- 4.304 uVs I2Y = -21.869 +- 0.396 uTm^2 17:41:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:41:06 Integrated Voltage Measurement... 17:41:15 Voltage Offset Correction: v_off_ini = 558.396 uV, v_off_fin = 550.637 uV 17:41:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.131 uVs 17:41:15 Integrated Voltage Measurement... 17:41:24 Voltage Offset Correction: v_off_ini = 552.423 uV, v_off_fin = 566.682 uV 17:41:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.467 uVs 17:41:24 Integrated Voltage Measurement... 17:41:33 Voltage Offset Correction: v_off_ini = 567.689 uV, v_off_fin = 569.321 uV 17:41:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.490 uVs 17:41:33 Integrated Voltage Measurement... 17:41:42 Voltage Offset Correction: v_off_ini = 576.075 uV, v_off_fin = 576.464 uV 17:41:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.345 uVs 17:41:42 Integrated Voltage Measurement... 17:41:51 Voltage Offset Correction: v_off_ini = 585.481 uV, v_off_fin = 565.926 uV 17:41:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.867 uVs 17:41:51 Integrated Voltage Measurement... 17:42:00 Voltage Offset Correction: v_off_ini = 575.200 uV, v_off_fin = 567.225 uV 17:42:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.314 uVs 17:42:04 I1X Average and RMS of Measurements VT = -99.602 +- 5.424 uVs I1X = 19.921 +- 1.085 uTm 17:42:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:42:11 Integrated Voltage Measurement... 17:42:20 Voltage Offset Correction: v_off_ini = 568.304 uV, v_off_fin = 559.028 uV 17:42:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.469 uVs 17:42:20 Integrated Voltage Measurement... 17:42:29 Voltage Offset Correction: v_off_ini = 574.751 uV, v_off_fin = 588.754 uV 17:42:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.132 uVs 17:42:29 Integrated Voltage Measurement... 17:42:38 Voltage Offset Correction: v_off_ini = 580.861 uV, v_off_fin = 568.578 uV 17:42:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.669 uVs 17:42:38 Integrated Voltage Measurement... 17:42:47 Voltage Offset Correction: v_off_ini = 577.579 uV, v_off_fin = 594.817 uV 17:42:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.374 uVs 17:42:47 Integrated Voltage Measurement... 17:42:56 Voltage Offset Correction: v_off_ini = 597.612 uV, v_off_fin = 584.914 uV 17:42:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.310 uVs 17:42:56 Integrated Voltage Measurement... 17:43:05 Voltage Offset Correction: v_off_ini = 581.873 uV, v_off_fin = 586.077 uV 17:43:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.853 uVs 17:43:09 I1Y Average and RMS of Measurements VT = -206.634 +- 1.382 uVs I1Y = -41.327 +- 0.276 uTm 17:43:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:43:17 Integrated Voltage Measurement... 17:43:26 Voltage Offset Correction: v_off_ini = 576.238 uV, v_off_fin = 574.690 uV 17:43:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.039 uVs 17:43:26 Integrated Voltage Measurement... 17:43:35 Voltage Offset Correction: v_off_ini = 584.004 uV, v_off_fin = 578.098 uV 17:43:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.043 uVs 17:43:35 Integrated Voltage Measurement... 17:43:44 Voltage Offset Correction: v_off_ini = 581.768 uV, v_off_fin = 566.055 uV 17:43:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.025 uVs 17:43:44 Integrated Voltage Measurement... 17:43:53 Voltage Offset Correction: v_off_ini = 576.662 uV, v_off_fin = 595.333 uV 17:43:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.060 uVs 17:43:53 Integrated Voltage Measurement... 17:44:02 Voltage Offset Correction: v_off_ini = 573.699 uV, v_off_fin = 556.194 uV 17:44:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.553 uVs 17:44:02 Integrated Voltage Measurement... 17:44:11 Voltage Offset Correction: v_off_ini = 549.137 uV, v_off_fin = 565.919 uV 17:44:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.834 uVs 17:44:14 I2X Average and RMS of Measurements VT = -119.426 +- 6.806 uVs I2X = 10.987 +- 0.626 uTm^2 17:44:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:44:21 Integrated Voltage Measurement... 17:44:30 Voltage Offset Correction: v_off_ini = 560.587 uV, v_off_fin = 571.070 uV 17:44:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.454 uVs 17:44:30 Integrated Voltage Measurement... 17:44:39 Voltage Offset Correction: v_off_ini = 567.410 uV, v_off_fin = 556.105 uV 17:44:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.700 uVs 17:44:39 Integrated Voltage Measurement... 17:44:48 Voltage Offset Correction: v_off_ini = 558.385 uV, v_off_fin = 550.930 uV 17:44:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.767 uVs 17:44:48 Integrated Voltage Measurement... 17:44:57 Voltage Offset Correction: v_off_ini = 565.698 uV, v_off_fin = 571.393 uV 17:44:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.857 uVs 17:44:57 Integrated Voltage Measurement... 17:45:06 Voltage Offset Correction: v_off_ini = 567.769 uV, v_off_fin = 564.856 uV 17:45:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.765 uVs 17:45:06 Integrated Voltage Measurement... 17:45:15 Voltage Offset Correction: v_off_ini = 563.875 uV, v_off_fin = 574.382 uV 17:45:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.574 uVs 17:45:18 I2Y Average and RMS of Measurements VT = -240.186 +- 2.392 uVs I2Y = -22.097 +- 0.220 uTm^2 17:45:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:45:27 Integrated Voltage Measurement... 17:45:36 Voltage Offset Correction: v_off_ini = 541.110 uV, v_off_fin = 534.053 uV 17:45:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.460 uVs 17:45:36 Integrated Voltage Measurement... 17:45:45 Voltage Offset Correction: v_off_ini = 553.419 uV, v_off_fin = 554.372 uV 17:45:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.895 uVs 17:45:45 Integrated Voltage Measurement... 17:45:54 Voltage Offset Correction: v_off_ini = 568.542 uV, v_off_fin = 550.074 uV 17:45:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.527 uVs 17:45:54 Integrated Voltage Measurement... 17:46:03 Voltage Offset Correction: v_off_ini = 544.697 uV, v_off_fin = 567.116 uV 17:46:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.733 uVs 17:46:03 Integrated Voltage Measurement... 17:46:12 Voltage Offset Correction: v_off_ini = 566.428 uV, v_off_fin = 561.765 uV 17:46:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.450 uVs 17:46:12 Integrated Voltage Measurement... 17:46:21 Voltage Offset Correction: v_off_ini = 562.139 uV, v_off_fin = 561.885 uV 17:46:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.207 uVs 17:46:25 I1X Average and RMS of Measurements VT = -79.712 +- 10.721 uVs I1X = 15.943 +- 2.144 uTm 17:46:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:46:32 Integrated Voltage Measurement... 17:46:41 Voltage Offset Correction: v_off_ini = 560.854 uV, v_off_fin = 556.424 uV 17:46:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.776 uVs 17:46:41 Integrated Voltage Measurement... 17:46:50 Voltage Offset Correction: v_off_ini = 561.097 uV, v_off_fin = 584.478 uV 17:46:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.367 uVs 17:46:50 Integrated Voltage Measurement... 17:46:59 Voltage Offset Correction: v_off_ini = 585.325 uV, v_off_fin = 569.446 uV 17:46:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.950 uVs 17:46:59 Integrated Voltage Measurement... 17:47:08 Voltage Offset Correction: v_off_ini = 578.126 uV, v_off_fin = 584.905 uV 17:47:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.609 uVs 17:47:08 Integrated Voltage Measurement... 17:47:17 Voltage Offset Correction: v_off_ini = 573.265 uV, v_off_fin = 569.221 uV 17:47:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.563 uVs 17:47:17 Integrated Voltage Measurement... 17:47:26 Voltage Offset Correction: v_off_ini = 610.125 uV, v_off_fin = 625.848 uV 17:47:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.090 uVs 17:47:30 I1Y Average and RMS of Measurements VT = -216.726 +- 7.547 uVs I1Y = -43.345 +- 1.509 uTm 17:47:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:47:38 Integrated Voltage Measurement... 17:47:47 Voltage Offset Correction: v_off_ini = 584.237 uV, v_off_fin = 588.204 uV 17:47:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.663 uVs 17:47:47 Integrated Voltage Measurement... 17:47:56 Voltage Offset Correction: v_off_ini = 596.697 uV, v_off_fin = 606.578 uV 17:47:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.734 uVs 17:47:56 Integrated Voltage Measurement... 17:48:05 Voltage Offset Correction: v_off_ini = 626.004 uV, v_off_fin = 607.209 uV 17:48:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.688 uVs 17:48:05 Integrated Voltage Measurement... 17:48:14 Voltage Offset Correction: v_off_ini = 588.342 uV, v_off_fin = 606.765 uV 17:48:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.106 uVs 17:48:14 Integrated Voltage Measurement... 17:48:23 Voltage Offset Correction: v_off_ini = 614.784 uV, v_off_fin = 593.221 uV 17:48:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.213 uVs 17:48:23 Integrated Voltage Measurement... 17:48:32 Voltage Offset Correction: v_off_ini = 599.667 uV, v_off_fin = 609.535 uV 17:48:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.813 uVs 17:48:34 I2X Average and RMS of Measurements VT = -107.869 +- 12.297 uVs I2X = 9.924 +- 1.131 uTm^2 17:48:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:48:42 Integrated Voltage Measurement... 17:48:51 Voltage Offset Correction: v_off_ini = 603.196 uV, v_off_fin = 601.876 uV 17:48:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.667 uVs 17:48:51 Integrated Voltage Measurement... 17:49:00 Voltage Offset Correction: v_off_ini = 621.263 uV, v_off_fin = 604.876 uV 17:49:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.886 uVs 17:49:00 Integrated Voltage Measurement... 17:49:09 Voltage Offset Correction: v_off_ini = 609.143 uV, v_off_fin = 612.915 uV 17:49:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.769 uVs 17:49:09 Integrated Voltage Measurement... 17:49:18 Voltage Offset Correction: v_off_ini = 616.416 uV, v_off_fin = 622.462 uV 17:49:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.075 uVs 17:49:18 Integrated Voltage Measurement... 17:49:27 Voltage Offset Correction: v_off_ini = 610.580 uV, v_off_fin = 607.555 uV 17:49:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.831 uVs 17:49:27 Integrated Voltage Measurement... 17:49:36 Voltage Offset Correction: v_off_ini = 624.547 uV, v_off_fin = 621.527 uV 17:49:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.524 uVs 17:49:39 I2Y Average and RMS of Measurements VT = -240.459 +- 3.677 uVs I2Y = -22.122 +- 0.338 uTm^2 17:49:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:49:48 Integrated Voltage Measurement... 17:49:57 Voltage Offset Correction: v_off_ini = 633.364 uV, v_off_fin = 618.953 uV 17:49:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.963 uVs 17:49:57 Integrated Voltage Measurement... 17:50:06 Voltage Offset Correction: v_off_ini = 635.162 uV, v_off_fin = 625.223 uV 17:50:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.406 uVs 17:50:06 Integrated Voltage Measurement... 17:50:15 Voltage Offset Correction: v_off_ini = 640.434 uV, v_off_fin = 640.816 uV 17:50:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.190 uVs 17:50:15 Integrated Voltage Measurement... 17:50:24 Voltage Offset Correction: v_off_ini = 648.455 uV, v_off_fin = 647.764 uV 17:50:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.568 uVs 17:50:24 Integrated Voltage Measurement... 17:50:33 Voltage Offset Correction: v_off_ini = 642.315 uV, v_off_fin = 642.136 uV 17:50:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.048 uVs 17:50:33 Integrated Voltage Measurement... 17:50:42 Voltage Offset Correction: v_off_ini = 646.481 uV, v_off_fin = 618.401 uV 17:50:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.643 uVs 17:50:46 I1X Average and RMS of Measurements VT = -78.970 +- 12.685 uVs I1X = 15.794 +- 2.537 uTm 17:50:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:50:53 Integrated Voltage Measurement... 17:51:02 Voltage Offset Correction: v_off_ini = 634.482 uV, v_off_fin = 640.158 uV 17:51:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.246 uVs 17:51:02 Integrated Voltage Measurement... 17:51:11 Voltage Offset Correction: v_off_ini = 645.365 uV, v_off_fin = 641.146 uV 17:51:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.749 uVs 17:51:11 Integrated Voltage Measurement... 17:51:20 Voltage Offset Correction: v_off_ini = 641.051 uV, v_off_fin = 645.003 uV 17:51:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.343 uVs 17:51:20 Integrated Voltage Measurement... 17:51:29 Voltage Offset Correction: v_off_ini = 645.473 uV, v_off_fin = 650.845 uV 17:51:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.924 uVs 17:51:29 Integrated Voltage Measurement... 17:51:38 Voltage Offset Correction: v_off_ini = 654.992 uV, v_off_fin = 624.313 uV 17:51:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.847 uVs 17:51:38 Integrated Voltage Measurement... 17:51:47 Voltage Offset Correction: v_off_ini = 631.585 uV, v_off_fin = 641.461 uV 17:51:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.656 uVs 17:51:51 I1Y Average and RMS of Measurements VT = -215.127 +- 3.039 uVs I1Y = -43.025 +- 0.608 uTm 17:51:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:51:59 Integrated Voltage Measurement... 17:52:08 Voltage Offset Correction: v_off_ini = 635.696 uV, v_off_fin = 636.938 uV 17:52:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.488 uVs 17:52:08 Integrated Voltage Measurement... 17:52:17 Voltage Offset Correction: v_off_ini = 627.965 uV, v_off_fin = 641.284 uV 17:52:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.952 uVs 17:52:17 Integrated Voltage Measurement... 17:52:26 Voltage Offset Correction: v_off_ini = 637.479 uV, v_off_fin = 627.515 uV 17:52:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.310 uVs 17:52:26 Integrated Voltage Measurement... 17:52:35 Voltage Offset Correction: v_off_ini = 633.566 uV, v_off_fin = 640.188 uV 17:52:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.039 uVs 17:52:35 Integrated Voltage Measurement... 17:52:44 Voltage Offset Correction: v_off_ini = 632.178 uV, v_off_fin = 609.341 uV 17:52:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.848 uVs 17:52:44 Integrated Voltage Measurement... 17:52:53 Voltage Offset Correction: v_off_ini = 607.309 uV, v_off_fin = 630.860 uV 17:52:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.951 uVs 17:52:55 I2X Average and RMS of Measurements VT = -101.265 +- 15.109 uVs I2X = 9.316 +- 1.390 uTm^2 17:53:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:53:03 Integrated Voltage Measurement... 17:53:12 Voltage Offset Correction: v_off_ini = 632.520 uV, v_off_fin = 616.277 uV 17:53:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.206 uVs 17:53:12 Integrated Voltage Measurement... 17:53:21 Voltage Offset Correction: v_off_ini = 622.210 uV, v_off_fin = 615.314 uV 17:53:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.120 uVs 17:53:21 Integrated Voltage Measurement... 17:53:30 Voltage Offset Correction: v_off_ini = 611.080 uV, v_off_fin = 608.087 uV 17:53:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.642 uVs 17:53:30 Integrated Voltage Measurement... 17:53:39 Voltage Offset Correction: v_off_ini = 617.751 uV, v_off_fin = 601.547 uV 17:53:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.721 uVs 17:53:39 Integrated Voltage Measurement... 17:53:48 Voltage Offset Correction: v_off_ini = 621.686 uV, v_off_fin = 606.454 uV 17:53:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.895 uVs 17:53:48 Integrated Voltage Measurement... 17:53:57 Voltage Offset Correction: v_off_ini = 614.009 uV, v_off_fin = 620.644 uV 17:53:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.921 uVs 17:53:59 I2Y Average and RMS of Measurements VT = -235.918 +- 9.774 uVs I2Y = -21.704 +- 0.899 uTm^2 17:54:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:54:11 Integrated Voltage Measurement... 17:54:20 Voltage Offset Correction: v_off_ini = 610.875 uV, v_off_fin = 609.248 uV 17:54:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.131 uVs 17:54:20 Integrated Voltage Measurement... 17:54:29 Voltage Offset Correction: v_off_ini = 607.074 uV, v_off_fin = 597.367 uV 17:54:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.517 uVs 17:54:29 Integrated Voltage Measurement... 17:54:38 Voltage Offset Correction: v_off_ini = 598.930 uV, v_off_fin = 623.821 uV 17:54:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.803 uVs 17:54:38 Integrated Voltage Measurement... 17:54:47 Voltage Offset Correction: v_off_ini = 591.618 uV, v_off_fin = 599.209 uV 17:54:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.624 uVs 17:54:47 Integrated Voltage Measurement... 17:54:56 Voltage Offset Correction: v_off_ini = 602.621 uV, v_off_fin = 615.662 uV 17:54:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.102 uVs 17:54:56 Integrated Voltage Measurement... 17:55:05 Voltage Offset Correction: v_off_ini = 615.912 uV, v_off_fin = 579.273 uV 17:55:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.020 uVs 17:55:09 I1X Average and RMS of Measurements VT = -93.033 +- 9.196 uVs I1X = 18.607 +- 1.839 uTm 17:55:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:55:16 Integrated Voltage Measurement... 17:55:25 Voltage Offset Correction: v_off_ini = 598.075 uV, v_off_fin = 595.552 uV 17:55:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.791 uVs 17:55:25 Integrated Voltage Measurement... 17:55:34 Voltage Offset Correction: v_off_ini = 600.341 uV, v_off_fin = 605.571 uV 17:55:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.127 uVs 17:55:34 Integrated Voltage Measurement... 17:55:43 Voltage Offset Correction: v_off_ini = 602.043 uV, v_off_fin = 599.802 uV 17:55:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.552 uVs 17:55:43 Integrated Voltage Measurement... 17:55:52 Voltage Offset Correction: v_off_ini = 597.299 uV, v_off_fin = 601.148 uV 17:55:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.637 uVs 17:55:52 Integrated Voltage Measurement... 17:56:01 Voltage Offset Correction: v_off_ini = 594.294 uV, v_off_fin = 586.044 uV 17:56:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.530 uVs 17:56:01 Integrated Voltage Measurement... 17:56:10 Voltage Offset Correction: v_off_ini = 592.694 uV, v_off_fin = 592.458 uV 17:56:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.627 uVs 17:56:14 I1Y Average and RMS of Measurements VT = -212.211 +- 7.813 uVs I1Y = -42.442 +- 1.563 uTm 17:56:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:56:19 Integrated Voltage Measurement... 17:56:28 Voltage Offset Correction: v_off_ini = 568.920 uV, v_off_fin = 561.244 uV 17:56:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.298 uVs 17:56:28 Integrated Voltage Measurement... 17:56:37 Voltage Offset Correction: v_off_ini = 570.473 uV, v_off_fin = 586.287 uV 17:56:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.445 uVs 17:56:37 Integrated Voltage Measurement... 17:56:46 Voltage Offset Correction: v_off_ini = 581.211 uV, v_off_fin = 574.899 uV 17:56:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.681 uVs 17:56:46 Integrated Voltage Measurement... 17:56:55 Voltage Offset Correction: v_off_ini = 582.579 uV, v_off_fin = 592.661 uV 17:56:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.260 uVs 17:56:56 Integrated Voltage Measurement... 17:57:05 Voltage Offset Correction: v_off_ini = 566.331 uV, v_off_fin = 571.722 uV 17:57:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.275 uVs 17:57:05 Integrated Voltage Measurement... 17:57:14 Voltage Offset Correction: v_off_ini = 579.455 uV, v_off_fin = 565.109 uV 17:57:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.686 uVs 17:57:16 I2X Average and RMS of Measurements VT = -127.108 +- 8.829 uVs I2X = 11.694 +- 0.812 uTm^2 17:57:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:57:21 Integrated Voltage Measurement... 17:57:30 Voltage Offset Correction: v_off_ini = 573.907 uV, v_off_fin = 572.471 uV 17:57:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.595 uVs 17:57:30 Integrated Voltage Measurement... 17:57:39 Voltage Offset Correction: v_off_ini = 572.152 uV, v_off_fin = 571.006 uV 17:57:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.282 uVs 17:57:39 Integrated Voltage Measurement... 17:57:48 Voltage Offset Correction: v_off_ini = 571.555 uV, v_off_fin = 587.551 uV 17:57:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.173 uVs 17:57:48 Integrated Voltage Measurement... 17:57:57 Voltage Offset Correction: v_off_ini = 586.666 uV, v_off_fin = 573.899 uV 17:57:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.060 uVs 17:57:57 Integrated Voltage Measurement... 17:58:06 Voltage Offset Correction: v_off_ini = 576.303 uV, v_off_fin = 584.765 uV 17:58:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.457 uVs 17:58:06 Integrated Voltage Measurement... 17:58:15 Voltage Offset Correction: v_off_ini = 578.712 uV, v_off_fin = 601.262 uV 17:58:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.843 uVs 17:58:18 I2Y Average and RMS of Measurements VT = -245.068 +- 3.949 uVs I2Y = -22.546 +- 0.363 uTm^2 17:58:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:58:26 Integrated Voltage Measurement... 17:58:35 Voltage Offset Correction: v_off_ini = 590.824 uV, v_off_fin = 573.261 uV 17:58:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.165 uVs 17:58:35 Integrated Voltage Measurement... 17:58:44 Voltage Offset Correction: v_off_ini = 577.143 uV, v_off_fin = 581.167 uV 17:58:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.600 uVs 17:58:44 Integrated Voltage Measurement... 17:58:53 Voltage Offset Correction: v_off_ini = 580.139 uV, v_off_fin = 588.171 uV 17:58:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.299 uVs 17:58:53 Integrated Voltage Measurement... 17:59:02 Voltage Offset Correction: v_off_ini = 576.544 uV, v_off_fin = 585.775 uV 17:59:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.920 uVs 17:59:02 Integrated Voltage Measurement... 17:59:11 Voltage Offset Correction: v_off_ini = 581.601 uV, v_off_fin = 588.511 uV 17:59:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.678 uVs 17:59:11 Integrated Voltage Measurement... 17:59:20 Voltage Offset Correction: v_off_ini = 602.101 uV, v_off_fin = 607.140 uV 17:59:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.097 uVs 17:59:24 I1X Average and RMS of Measurements VT = -100.460 +- 5.121 uVs I1X = 20.092 +- 1.024 uTm 17:59:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:59:31 Integrated Voltage Measurement... 17:59:40 Voltage Offset Correction: v_off_ini = 583.055 uV, v_off_fin = 587.061 uV 17:59:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.843 uVs 17:59:40 Integrated Voltage Measurement... 17:59:49 Voltage Offset Correction: v_off_ini = 594.025 uV, v_off_fin = 595.098 uV 17:59:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.862 uVs 17:59:49 Integrated Voltage Measurement... 17:59:58 Voltage Offset Correction: v_off_ini = 573.641 uV, v_off_fin = 580.862 uV 17:59:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.697 uVs 17:59:58 Integrated Voltage Measurement... 18:00:07 Voltage Offset Correction: v_off_ini = 585.127 uV, v_off_fin = 608.873 uV 18:00:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.137 uVs 18:00:07 Integrated Voltage Measurement... 18:00:16 Voltage Offset Correction: v_off_ini = 602.793 uV, v_off_fin = 593.568 uV 18:00:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.491 uVs 18:00:16 Integrated Voltage Measurement... 18:00:25 Voltage Offset Correction: v_off_ini = 586.766 uV, v_off_fin = 608.860 uV 18:00:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.787 uVs 18:00:29 I1Y Average and RMS of Measurements VT = -213.970 +- 5.602 uVs I1Y = -42.794 +- 1.120 uTm 18:00:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:00:34 Integrated Voltage Measurement... 18:00:43 Voltage Offset Correction: v_off_ini = 598.627 uV, v_off_fin = 592.176 uV 18:00:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.443 uVs 18:00:43 Integrated Voltage Measurement... 18:00:52 Voltage Offset Correction: v_off_ini = 589.100 uV, v_off_fin = 600.434 uV 18:00:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.917 uVs 18:00:52 Integrated Voltage Measurement... 18:01:01 Voltage Offset Correction: v_off_ini = 580.388 uV, v_off_fin = 575.596 uV 18:01:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -103.851 uVs 18:01:01 Integrated Voltage Measurement... 18:01:10 Voltage Offset Correction: v_off_ini = 588.427 uV, v_off_fin = 599.035 uV 18:01:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 138.528 uVs 18:01:11 Integrated Voltage Measurement... 18:01:19 Voltage Offset Correction: v_off_ini = 591.446 uV, v_off_fin = 585.668 uV 18:01:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.572 uVs 18:01:20 Integrated Voltage Measurement... 18:01:29 Voltage Offset Correction: v_off_ini = 582.624 uV, v_off_fin = 597.880 uV 18:01:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.054 uVs 18:01:31 I2X Average and RMS of Measurements VT = -125.728 +- 8.156 uVs I2X = 11.567 +- 0.750 uTm^2 18:01:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:01:36 Integrated Voltage Measurement... 18:01:45 Voltage Offset Correction: v_off_ini = 584.746 uV, v_off_fin = 585.280 uV 18:01:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.116 uVs 18:01:45 Integrated Voltage Measurement... 18:01:54 Voltage Offset Correction: v_off_ini = 584.173 uV, v_off_fin = 586.831 uV 18:01:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.306 uVs 18:01:54 Integrated Voltage Measurement... 18:02:03 Voltage Offset Correction: v_off_ini = 577.590 uV, v_off_fin = 586.977 uV 18:02:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.812 uVs 18:02:03 Integrated Voltage Measurement... 18:02:12 Voltage Offset Correction: v_off_ini = 563.887 uV, v_off_fin = 561.766 uV 18:02:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.726 uVs 18:02:12 Integrated Voltage Measurement... 18:02:21 Voltage Offset Correction: v_off_ini = 551.581 uV, v_off_fin = 557.218 uV 18:02:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.349 uVs 18:02:21 Integrated Voltage Measurement... 18:02:30 Voltage Offset Correction: v_off_ini = 538.003 uV, v_off_fin = 560.559 uV 18:02:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 239.371 uVs 18:02:33 I2Y Average and RMS of Measurements VT = -244.447 +- 5.636 uVs I2Y = -22.489 +- 0.518 uTm^2 18:02:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:02:41 Integrated Voltage Measurement... 18:02:50 Voltage Offset Correction: v_off_ini = 541.399 uV, v_off_fin = 545.486 uV 18:02:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.427 uVs 18:02:50 Integrated Voltage Measurement... 18:02:59 Voltage Offset Correction: v_off_ini = 552.264 uV, v_off_fin = 535.134 uV 18:02:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.530 uVs 18:02:59 Integrated Voltage Measurement... 18:03:08 Voltage Offset Correction: v_off_ini = 552.424 uV, v_off_fin = 544.356 uV 18:03:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.443 uVs 18:03:08 Integrated Voltage Measurement... 18:03:17 Voltage Offset Correction: v_off_ini = 563.656 uV, v_off_fin = 571.684 uV 18:03:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.647 uVs 18:03:17 Integrated Voltage Measurement... 18:03:26 Voltage Offset Correction: v_off_ini = 563.659 uV, v_off_fin = 558.339 uV 18:03:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.030 uVs 18:03:26 Integrated Voltage Measurement... 18:03:35 Voltage Offset Correction: v_off_ini = 555.312 uV, v_off_fin = 560.295 uV 18:03:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.924 uVs 18:03:39 I1X Average and RMS of Measurements VT = -102.667 +- 3.088 uVs I1X = 20.534 +- 0.618 uTm 18:03:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:03:46 Integrated Voltage Measurement... 18:03:55 Voltage Offset Correction: v_off_ini = 534.690 uV, v_off_fin = 543.442 uV 18:03:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -188.111 uVs 18:03:55 Integrated Voltage Measurement... 18:04:04 Voltage Offset Correction: v_off_ini = 539.013 uV, v_off_fin = 544.480 uV 18:04:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.567 uVs 18:04:04 Integrated Voltage Measurement... 18:04:13 Voltage Offset Correction: v_off_ini = 563.853 uV, v_off_fin = 540.740 uV 18:04:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.618 uVs 18:04:13 Integrated Voltage Measurement... 18:04:22 Voltage Offset Correction: v_off_ini = 560.853 uV, v_off_fin = 571.934 uV 18:04:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.768 uVs 18:04:22 Integrated Voltage Measurement... 18:04:31 Voltage Offset Correction: v_off_ini = 568.126 uV, v_off_fin = 558.589 uV 18:04:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.113 uVs 18:04:31 Integrated Voltage Measurement... 18:04:40 Voltage Offset Correction: v_off_ini = 558.287 uV, v_off_fin = 576.034 uV 18:04:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.935 uVs 18:04:44 I1Y Average and RMS of Measurements VT = -203.185 +- 9.620 uVs I1Y = -40.634 +- 1.923 uTm 18:04:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:04:49 Integrated Voltage Measurement... 18:04:58 Voltage Offset Correction: v_off_ini = 557.253 uV, v_off_fin = 563.737 uV 18:04:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.054 uVs 18:04:58 Integrated Voltage Measurement... 18:05:07 Voltage Offset Correction: v_off_ini = 578.030 uV, v_off_fin = 558.247 uV 18:05:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.482 uVs 18:05:07 Integrated Voltage Measurement... 18:05:16 Voltage Offset Correction: v_off_ini = 550.575 uV, v_off_fin = 539.807 uV 18:05:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.869 uVs 18:05:16 Integrated Voltage Measurement... 18:05:25 Voltage Offset Correction: v_off_ini = 555.843 uV, v_off_fin = 547.496 uV 18:05:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.456 uVs 18:05:25 Integrated Voltage Measurement... 18:05:34 Voltage Offset Correction: v_off_ini = 552.189 uV, v_off_fin = 534.733 uV 18:05:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.905 uVs 18:05:34 Integrated Voltage Measurement... 18:05:43 Voltage Offset Correction: v_off_ini = 546.226 uV, v_off_fin = 558.373 uV 18:05:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.794 uVs 18:05:46 I2X Average and RMS of Measurements VT = -125.927 +- 5.889 uVs I2X = 11.585 +- 0.542 uTm^2 18:05:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:05:51 Integrated Voltage Measurement... 18:06:00 Voltage Offset Correction: v_off_ini = 547.312 uV, v_off_fin = 531.402 uV 18:06:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.370 uVs 18:06:00 Integrated Voltage Measurement... 18:06:09 Voltage Offset Correction: v_off_ini = 535.375 uV, v_off_fin = 534.666 uV 18:06:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.305 uVs 18:06:09 Integrated Voltage Measurement... 18:06:18 Voltage Offset Correction: v_off_ini = 540.446 uV, v_off_fin = 547.488 uV 18:06:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.379 uVs 18:06:18 Integrated Voltage Measurement... 18:06:27 Voltage Offset Correction: v_off_ini = 541.236 uV, v_off_fin = 546.221 uV 18:06:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.123 uVs 18:06:27 Integrated Voltage Measurement... 18:06:36 Voltage Offset Correction: v_off_ini = 540.999 uV, v_off_fin = 536.392 uV 18:06:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.545 uVs 18:06:36 Integrated Voltage Measurement... 18:06:45 Voltage Offset Correction: v_off_ini = 525.865 uV, v_off_fin = 532.401 uV 18:06:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.534 uVs 18:06:47 I2Y Average and RMS of Measurements VT = -234.376 +- 5.020 uVs I2Y = -21.563 +- 0.462 uTm^2 18:06:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:06:56 Integrated Voltage Measurement... 18:07:05 Voltage Offset Correction: v_off_ini = 524.862 uV, v_off_fin = 522.050 uV 18:07:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -70.352 uVs 18:07:05 Integrated Voltage Measurement... 18:07:14 Voltage Offset Correction: v_off_ini = 536.665 uV, v_off_fin = 540.007 uV 18:07:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.907 uVs 18:07:14 Integrated Voltage Measurement... 18:07:23 Voltage Offset Correction: v_off_ini = 552.790 uV, v_off_fin = 528.455 uV 18:07:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.315 uVs 18:07:23 Integrated Voltage Measurement... 18:07:32 Voltage Offset Correction: v_off_ini = 538.150 uV, v_off_fin = 568.564 uV 18:07:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.435 uVs 18:07:32 Integrated Voltage Measurement... 18:07:41 Voltage Offset Correction: v_off_ini = 550.738 uV, v_off_fin = 557.591 uV 18:07:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.257 uVs 18:07:41 Integrated Voltage Measurement... 18:07:50 Voltage Offset Correction: v_off_ini = 552.560 uV, v_off_fin = 550.777 uV 18:07:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.772 uVs 18:07:54 I1X Average and RMS of Measurements VT = -90.340 +- 6.842 uVs I1X = 18.068 +- 1.368 uTm 18:07:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:08:01 Integrated Voltage Measurement... 18:08:10 Voltage Offset Correction: v_off_ini = 556.551 uV, v_off_fin = 540.507 uV 18:08:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -213.016 uVs 18:08:10 Integrated Voltage Measurement... 18:08:19 Voltage Offset Correction: v_off_ini = 567.878 uV, v_off_fin = 582.679 uV 18:08:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.829 uVs 18:08:19 Integrated Voltage Measurement... 18:08:28 Voltage Offset Correction: v_off_ini = 557.767 uV, v_off_fin = 556.939 uV 18:08:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.353 uVs 18:08:28 Integrated Voltage Measurement... 18:08:37 Voltage Offset Correction: v_off_ini = 551.100 uV, v_off_fin = 579.778 uV 18:08:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.445 uVs 18:08:37 Integrated Voltage Measurement... 18:08:46 Voltage Offset Correction: v_off_ini = 552.282 uV, v_off_fin = 546.623 uV 18:08:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.382 uVs 18:08:46 Integrated Voltage Measurement... 18:08:55 Voltage Offset Correction: v_off_ini = 564.141 uV, v_off_fin = 572.854 uV 18:08:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.938 uVs 18:08:59 I1Y Average and RMS of Measurements VT = -203.827 +- 4.241 uVs I1Y = -40.765 +- 0.850 uTm 18:09:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:09:04 Integrated Voltage Measurement... 18:09:13 Voltage Offset Correction: v_off_ini = 546.002 uV, v_off_fin = 553.459 uV 18:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.736 uVs 18:09:13 Integrated Voltage Measurement... 18:09:22 Voltage Offset Correction: v_off_ini = 572.302 uV, v_off_fin = 560.603 uV 18:09:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.174 uVs 18:09:22 Integrated Voltage Measurement... 18:09:31 Voltage Offset Correction: v_off_ini = 569.092 uV, v_off_fin = 565.797 uV 18:09:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.494 uVs 18:09:31 Integrated Voltage Measurement... 18:09:40 Voltage Offset Correction: v_off_ini = 559.115 uV, v_off_fin = 568.588 uV 18:09:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.847 uVs 18:09:40 Integrated Voltage Measurement... 18:09:49 Voltage Offset Correction: v_off_ini = 570.605 uV, v_off_fin = 589.526 uV 18:09:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.500 uVs 18:09:49 Integrated Voltage Measurement... 18:09:58 Voltage Offset Correction: v_off_ini = 578.334 uV, v_off_fin = 583.633 uV 18:09:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.176 uVs 18:10:01 I2X Average and RMS of Measurements VT = -108.321 +- 0.805 uVs I2X = 9.966 +- 0.074 uTm^2 18:10:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:10:06 Integrated Voltage Measurement... 18:10:15 Voltage Offset Correction: v_off_ini = 574.396 uV, v_off_fin = 562.505 uV 18:10:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.180 uVs 18:10:15 Integrated Voltage Measurement... 18:10:24 Voltage Offset Correction: v_off_ini = 564.375 uV, v_off_fin = 570.468 uV 18:10:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.902 uVs 18:10:24 Integrated Voltage Measurement... 18:10:33 Voltage Offset Correction: v_off_ini = 566.300 uV, v_off_fin = 576.681 uV 18:10:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.490 uVs 18:10:33 Integrated Voltage Measurement... 18:10:42 Voltage Offset Correction: v_off_ini = 566.613 uV, v_off_fin = 579.175 uV 18:10:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.842 uVs 18:10:42 Integrated Voltage Measurement... 18:10:51 Voltage Offset Correction: v_off_ini = 587.017 uV, v_off_fin = 573.016 uV 18:10:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.686 uVs 18:10:51 Integrated Voltage Measurement... 18:11:00 Voltage Offset Correction: v_off_ini = 570.405 uV, v_off_fin = 570.289 uV 18:11:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.455 uVs 18:11:02 I2Y Average and RMS of Measurements VT = -242.426 +- 11.042 uVs I2Y = -22.303 +- 1.016 uTm^2 18:11:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:11:11 Integrated Voltage Measurement... 18:11:20 Voltage Offset Correction: v_off_ini = 590.056 uV, v_off_fin = 572.287 uV 18:11:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.058 uVs 18:11:20 Integrated Voltage Measurement... 18:11:29 Voltage Offset Correction: v_off_ini = 546.226 uV, v_off_fin = 573.123 uV 18:11:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.125 uVs 18:11:29 Integrated Voltage Measurement... 18:11:38 Voltage Offset Correction: v_off_ini = 589.580 uV, v_off_fin = 572.317 uV 18:11:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.090 uVs 18:11:38 Integrated Voltage Measurement... 18:11:47 Voltage Offset Correction: v_off_ini = 591.124 uV, v_off_fin = 568.575 uV 18:11:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.574 uVs 18:11:47 Integrated Voltage Measurement... 18:11:56 Voltage Offset Correction: v_off_ini = 552.728 uV, v_off_fin = 556.644 uV 18:11:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.856 uVs 18:11:56 Integrated Voltage Measurement... 18:12:05 Voltage Offset Correction: v_off_ini = 569.698 uV, v_off_fin = 563.717 uV 18:12:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.780 uVs 18:12:09 I1X Average and RMS of Measurements VT = -97.581 +- 6.499 uVs I1X = 19.517 +- 1.300 uTm 18:12:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:12:16 Integrated Voltage Measurement... 18:12:25 Voltage Offset Correction: v_off_ini = 584.521 uV, v_off_fin = 562.153 uV 18:12:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -215.083 uVs 18:12:25 Integrated Voltage Measurement... 18:12:34 Voltage Offset Correction: v_off_ini = 577.573 uV, v_off_fin = 578.883 uV 18:12:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.681 uVs 18:12:34 Integrated Voltage Measurement... 18:12:42 Voltage Offset Correction: v_off_ini = 567.141 uV, v_off_fin = 553.370 uV 18:12:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.969 uVs 18:12:43 Integrated Voltage Measurement... 18:12:51 Voltage Offset Correction: v_off_ini = 578.236 uV, v_off_fin = 570.786 uV 18:12:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.193 uVs 18:12:52 Integrated Voltage Measurement... 18:13:00 Voltage Offset Correction: v_off_ini = 570.041 uV, v_off_fin = 565.280 uV 18:13:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.338 uVs 18:13:01 Integrated Voltage Measurement... 18:13:09 Voltage Offset Correction: v_off_ini = 552.126 uV, v_off_fin = 571.356 uV 18:13:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.826 uVs 18:13:14 I1Y Average and RMS of Measurements VT = -200.015 +- 4.225 uVs I1Y = -40.002 +- 0.846 uTm 18:13:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:13:19 Integrated Voltage Measurement... 18:13:28 Voltage Offset Correction: v_off_ini = 563.220 uV, v_off_fin = 570.296 uV 18:13:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.727 uVs 18:13:28 Integrated Voltage Measurement... 18:13:37 Voltage Offset Correction: v_off_ini = 582.563 uV, v_off_fin = 577.692 uV 18:13:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.247 uVs 18:13:37 Integrated Voltage Measurement... 18:13:46 Voltage Offset Correction: v_off_ini = 579.807 uV, v_off_fin = 567.360 uV 18:13:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.244 uVs 18:13:46 Integrated Voltage Measurement... 18:13:55 Voltage Offset Correction: v_off_ini = 545.411 uV, v_off_fin = 573.864 uV 18:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.544 uVs 18:13:55 Integrated Voltage Measurement... 18:14:04 Voltage Offset Correction: v_off_ini = 566.165 uV, v_off_fin = 566.794 uV 18:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.053 uVs 18:14:04 Integrated Voltage Measurement... 18:14:13 Voltage Offset Correction: v_off_ini = 578.534 uV, v_off_fin = 587.009 uV 18:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.673 uVs 18:14:15 I2X Average and RMS of Measurements VT = -93.915 +- 1.918 uVs I2X = 8.640 +- 0.176 uTm^2 18:14:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:14:20 Integrated Voltage Measurement... 18:14:29 Voltage Offset Correction: v_off_ini = 589.196 uV, v_off_fin = 588.657 uV 18:14:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.406 uVs 18:14:29 Integrated Voltage Measurement... 18:14:38 Voltage Offset Correction: v_off_ini = 579.332 uV, v_off_fin = 582.736 uV 18:14:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.979 uVs 18:14:39 Integrated Voltage Measurement... 18:14:47 Voltage Offset Correction: v_off_ini = 573.668 uV, v_off_fin = 572.018 uV 18:14:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.815 uVs 18:14:48 Integrated Voltage Measurement... 18:14:57 Voltage Offset Correction: v_off_ini = 588.655 uV, v_off_fin = 596.865 uV 18:14:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.729 uVs 18:14:57 Integrated Voltage Measurement... 18:15:06 Voltage Offset Correction: v_off_ini = 607.646 uV, v_off_fin = 598.858 uV 18:15:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.695 uVs 18:15:06 Integrated Voltage Measurement... 18:15:15 Voltage Offset Correction: v_off_ini = 576.991 uV, v_off_fin = 577.500 uV 18:15:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.520 uVs 18:15:17 I2Y Average and RMS of Measurements VT = -240.691 +- 12.306 uVs I2Y = -22.144 +- 1.132 uTm^2 18:15:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm