SLAC Magnetic Measurements Date: 03-17-2025 Time: 12:45:39 Project: LCLS-II Magnet Type: Phase Shifter Magnet Name: HXPS_16321 Dataset Number: 5 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 2 Measurement Device: Operator: YL Comment: 12:45:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:45:49 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:45:50 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:45:52 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:45:53 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:46:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:46:04 Integrated Voltage Measurement... 12:46:13 Voltage Offset Correction: v_off_ini = 18.089 uV, v_off_fin = 24.518 uV 12:46:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -95.918 uVs 12:46:13 Integrated Voltage Measurement... 12:46:22 Voltage Offset Correction: v_off_ini = 21.563 uV, v_off_fin = 28.381 uV 12:46:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.170 uVs 12:46:22 Integrated Voltage Measurement... 12:46:31 Voltage Offset Correction: v_off_ini = 40.581 uV, v_off_fin = 35.161 uV 12:46:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.310 uVs 12:46:31 Integrated Voltage Measurement... 12:46:40 Voltage Offset Correction: v_off_ini = 50.973 uV, v_off_fin = 37.832 uV 12:46:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.140 uVs 12:46:40 Integrated Voltage Measurement... 12:46:49 Voltage Offset Correction: v_off_ini = 44.623 uV, v_off_fin = 33.497 uV 12:46:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.009 uVs 12:46:49 Integrated Voltage Measurement... 12:46:58 Voltage Offset Correction: v_off_ini = 63.393 uV, v_off_fin = 38.131 uV 12:46:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.308 uVs 12:47:02 I1X Average and RMS of Measurements VT = -106.642 +- 0.441 uVs I1X = 21.329 +- 0.088 uTm 12:47:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:47:09 Integrated Voltage Measurement... 12:47:18 Voltage Offset Correction: v_off_ini = 29.684 uV, v_off_fin = 36.620 uV 12:47:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.643 uVs 12:47:18 Integrated Voltage Measurement... 12:47:27 Voltage Offset Correction: v_off_ini = 31.092 uV, v_off_fin = 39.392 uV 12:47:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.998 uVs 12:47:27 Integrated Voltage Measurement... 12:47:36 Voltage Offset Correction: v_off_ini = 21.701 uV, v_off_fin = 26.320 uV 12:47:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -230.510 uVs 12:47:36 Integrated Voltage Measurement... 12:47:45 Voltage Offset Correction: v_off_ini = 38.128 uV, v_off_fin = 37.797 uV 12:47:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.163 uVs 12:47:45 Integrated Voltage Measurement... 12:47:54 Voltage Offset Correction: v_off_ini = 39.048 uV, v_off_fin = 26.309 uV 12:47:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.699 uVs 12:47:54 Integrated Voltage Measurement... 12:48:03 Voltage Offset Correction: v_off_ini = 38.548 uV, v_off_fin = 29.281 uV 12:48:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.229 uVs 12:48:07 I1Y Average and RMS of Measurements VT = -215.707 +- 7.948 uVs I1Y = -43.143 +- 1.591 uTm 12:48:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:48:15 Integrated Voltage Measurement... 12:48:24 Voltage Offset Correction: v_off_ini = 53.957 uV, v_off_fin = 56.265 uV 12:48:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.728 uVs 12:48:24 Integrated Voltage Measurement... 12:48:33 Voltage Offset Correction: v_off_ini = 51.139 uV, v_off_fin = 31.926 uV 12:48:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.600 uVs 12:48:33 Integrated Voltage Measurement... 12:48:42 Voltage Offset Correction: v_off_ini = 41.935 uV, v_off_fin = 45.450 uV 12:48:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.795 uVs 12:48:42 Integrated Voltage Measurement... 12:48:51 Voltage Offset Correction: v_off_ini = 26.876 uV, v_off_fin = 31.109 uV 12:48:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.069 uVs 12:48:51 Integrated Voltage Measurement... 12:49:00 Voltage Offset Correction: v_off_ini = 31.747 uV, v_off_fin = 47.532 uV 12:49:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.551 uVs 12:49:00 Integrated Voltage Measurement... 12:49:09 Voltage Offset Correction: v_off_ini = 41.667 uV, v_off_fin = 27.815 uV 12:49:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.157 uVs 12:49:12 I2X Average and RMS of Measurements VT = -97.817 +- 10.308 uVs I2X = 8.999 +- 0.948 uTm^2 12:49:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:49:20 Integrated Voltage Measurement... 12:49:29 Voltage Offset Correction: v_off_ini = 15.066 uV, v_off_fin = 26.688 uV 12:49:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.364 uVs 12:49:29 Integrated Voltage Measurement... 12:49:38 Voltage Offset Correction: v_off_ini = 32.614 uV, v_off_fin = 39.537 uV 12:49:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.675 uVs 12:49:38 Integrated Voltage Measurement... 12:49:47 Voltage Offset Correction: v_off_ini = 38.270 uV, v_off_fin = 34.919 uV 12:49:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.270 uVs 12:49:47 Integrated Voltage Measurement... 12:49:56 Voltage Offset Correction: v_off_ini = 37.444 uV, v_off_fin = 32.296 uV 12:49:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.588 uVs 12:49:56 Integrated Voltage Measurement... 12:50:05 Voltage Offset Correction: v_off_ini = 43.657 uV, v_off_fin = 47.639 uV 12:50:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.017 uVs 12:50:05 Integrated Voltage Measurement... 12:50:14 Voltage Offset Correction: v_off_ini = 35.718 uV, v_off_fin = 31.613 uV 12:50:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.127 uVs 12:50:16 I2Y Average and RMS of Measurements VT = -229.674 +- 10.550 uVs I2Y = -21.130 +- 0.971 uTm^2 12:50:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm