Coil Constant for DC55 add using magnet FACET Sext S1E#1 Wire Strength = 5.1758 T/m/I, Coil Strength = 5.2023 T/m/I Old Coil Constant = 13938.4215, Old Coil Radius = 0.0162386, New Constant/Old Constant = 0.9949 New Calibrated Coil Constant = 13867.33170 New Radius = 0.0164050 , Number of Turns = 49 Magnet Type is Sextupole at Imag = 50.026 for coil Calculated Coil Constant = 14298.1360