Coil Constant for DC34 qadd using magnet FACET Quad Q5E#2 Old Coil Constant = 252.8649, Old Coil Radius = 0.0088900, New Constant/Old Constant = 1.0004 New Calibrated Coil Constant = 252.97629 New Radius = 0.0088915 , Number of Turns = 50 Magnet Type is Quadrupole at Imag = 160.000 for coil Calculated Coil Constant = 253.0617