Coil Constant for DC55_add using magnet Facet Quad Q4E#3 Wire Strength = 0.1338 T, Coil Strength = 0.1338 T Old Coil Constant = 75.9204, Old Coil Radius = 0.0163487, New Constant/Old Constant = 1.0002 New Calibrated Coil Constant = 75.93840 New Radius = 0.0163935 , Number of Turns = 49 Magnet Type is Quadrupole at Imag = 193.520 for coil Calculated Coil Constant = 76.3550