Coil Constant for 1DQB26 Main Coil 2 using magnet Sext TB05SX1 New Calibrated Coil Constant = 317566.65584, File coilpar.ru (Old) Coil Constant = 316623.70720 New Constant/Old Constant = 1.0030, Old Coil Radius = 0.0124310, New Radius = 0.0123625, Number of coils = 1 (Only change radius if Number of coils = 1!) Wire Strength = 10.278539 T/m, Coil Strength = 10.248019 T/m, Magnet Type is Sextupole at Imag = 7.000 for coil. Number of Coil Turns = 10 Coil Constant Calculated from radius, turns and magnet order = 312343.9161 (Should be within 5% of Calibrated Coil Constant)