Coil Constant for DC24 A + B measuring magnet ATF2 Sext FFSD4 New Coil Constant = 12945.33427 New Radius = 0.0154367 , Number of Turns = 63 Magnet Type is Sextupole at Imag = 50.000 for coil Old Coil Constant = 13243.5498, Old Coil Radius = 0.0154017, New Constant/Old Constant = 0.9775 Expected Constant = 13033.9102