SLAC Magnetic Measurements Date: 03-03-2008 Time: 11:46:06 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 03-03-2008 Time: 11:35:44 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-16 DATASET Number: 1 Tuning Stage: Fine Tuning Run Number: 2 Measurement Type: Z Scans Operator: YL Comment: find Y at min B Measurement Device x: Measurement Device y: SENTRON_441 Data File: s:\magdata\LCLS\Undulator\L143-112000-16\DATASET0001\Fine Tuning\Z Scans\Run 002\bscanz.dat Temperature (C) L143-112000-16:--> top_end 19.89 --> top_mid 19.91 --> top_start 19.94 --> bottom 19.91 --> Air 20.00 --> Granite 19.90 Axes position (m) X:0.029830 Y:0.000425 Initial Hall Probe Zero Measurements: Vx_0i = 0.001631 V Vy_0i = -0.000709 V Final Hall Probe Zero Measurements: Vx_0f = 0.001651 V Vy_0f = -0.000686 V Offset Correction Voff = offset+index*increment index = 0,1...21250 Vx:offset = 0.001631 V, increment = 9.247E-10 V Vy:offset = -0.000709 V, increment = 1.081E-09 V Hall Probe Calibration File: Y: c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = S:\MagData\LCLS\Undulator\L143-112000-16\DATASET0001\Fine Tuning\Z Scans\Run 002\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = -0.000015 T Correction, By additive constant = 0.000004 T Correction Bxy additive file = none Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26660.920000 Electron energy = 13.623705 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.493115 Nominal radiation wavelength = 1.498497e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = -0.000015 T CORR_BY_ADD = 0.000004 T CORR_BX_ADD_FILE = none CORR_BY_ADD_FILE = none !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.274257 T, RMS = 0.006248 T Peak Field Spacing: Ave = 0.015002 m, RMS = 0.000031 m Zero Field Spacing: Ave = 0.015002 m, RMS = 0.000043 m Average Undulator Period = 0.030003 m Hall Probe Overall Field Integrals: Int Bx dz = 2.4500e-005 Tm Int Int Bx dz dz = 7.7036e-005 Tm^2 Int By dz = 3.8082e-005 Tm Int Int By dz dz = 7.0222e-005 Tm^2 Trajectory Exit Information: X at exit = 1.5453e-006 m X slope at exit = 8.3801e-007 Y at exit = -1.6952e-006 m Y slope at exit = -5.3913e-007 Calculated Undulator Parameters: Keff = 3.494263 Beff = 1.247302 T Lambda_rad = 1.499488e-010 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 19.912500 C Measured Keff = 3.494263 Calculated Keff at 20 C = 3.494110 Relative Change (Keff_20C - Keff) / Keff = -0.000044 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 4.99781e-009 Undulator Period = 0.030003 m Radiation Wavelength = 1.49949e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = 0.000000 deg, RMS = 3.954897 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49850e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = -0.339518 deg, RMS = 3.837768 deg Center: Phase Error Of All Poles In Undulator Center: Ave = 9.531085 deg, RMS = 7.841393 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = 2.531650 deg, RMS = 5.006560 deg Cell: Phase Change Of Cell = 40702.503 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = 22.503 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 19.912500 C Measured Phase Change Of Cell = 40702.503 deg Calculated Phase Change Of Cell At 20 C = 40699.443 deg Phase Change Due To Temperature (Phase_20C - Phase) = -3.060 deg