SLAC Magnetic Measurements Date: 07-14-2026 Time: 14:49:03 Project: LCLS Magnet Type: Quad Magnet Name: 000422 Serial Number: Run Number: 3 Measurement Device: 1DQSB26_B2 Operator: sda Comment: Degauss using Degauss Currents f = 0.89 totals point = 45 Imax = 12 A Standardization for MAIN: 1 cycles from -12.0 A to 12.0 A to -12.0 A Test Currents for MAIN (A): 12.00 -10.68 9.51 -8.46 7.53 -6.70 5.96 -5.31 4.72 -4.20 3.74 -3.33 2.96 -2.64 2.35 -2.09 1.86 -1.66 1.47 -1.31 1.17 -1.04 0.92 -0.82 0.73 -0.65 0.58 -0.52 0.46 -0.41 0.36 -0.32 0.29 -0.26 0.23 -0.20 0.18 -0.16 0.14 -0.13 0.11 -0.10 0.09 -0.08 0.00