SLAC Magnetic Measurements Date: 01-30-2019 Time: 11:27:09 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_019 DATASET Number: 1 Tuning Stage: Tuning Run Number: 7 Measurement Type: Long Coil Scans Operator: YL Comment: Tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_X 0.000E-03 -3.810E-06 -183.248E-06 7.20000 7.19955 4425095 7.19985 4426693 7.19955 4425095 7.19985 4426693 I2X_VS_X 0.000E-03 -3.994E-06 -192.079E-06 7.20000 7.19955 4425095 7.19985 4426693 7.19950 4425096 7.19990 4426692 I2X_VS_X 0.000E-03 -4.073E-06 -195.898E-06 7.20000 7.19955 4425095 7.19985 4426693 7.19955 4425095 7.19985 4426693