SLAC Magnetic Measurements Date: 12-03-2018 Time: 10:43:07 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_017 DATASET Number: 1 Tuning Stage: Tuning Run Number: 44 Measurement Type: Long Coil Scans Operator: YL Comment: Data for tuning; round 5 Nom Gap Position X I1X I2X I1Y I2Y --------------------------------------------------------------------------- 7.20000 0.000E-03 10.943E-06 0.000E-06 12.149E-06 0.000E-06 7.20000 0.000E-03 13.058E-06 0.000E-06 10.420E-06 0.000E-06 7.20000 -2.000E-03 49.030E-06 0.000E-06 14.100E-06 0.000E-06 7.50000 -2.000E-03 34.019E-06 0.000E-06 -2.557E-06 0.000E-06 7.50000 -2.000E-03 24.376E-06 0.000E-06 -3.585E-06 0.000E-06 7.50000 -2.000E-03 29.371E-06 0.000E-06 -0.487E-06 0.000E-06 10.00000 -2.000E-03 -10.626E-06 0.000E-06 -1.548E-06 0.000E-06 10.00000 -2.000E-03 -12.502E-06 0.000E-06 -1.496E-06 0.000E-06 10.00000 -2.000E-03 -12.463E-06 0.000E-06 -2.134E-06 0.000E-06 13.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 13.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 13.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 16.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 16.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 16.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 22.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 22.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 22.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06