SLAC Magnetic Measurements Date: 12-03-2018 Time: 10:43:07 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_017 DATASET Number: 1 Tuning Stage: Tuning Run Number: 44 Measurement Type: Long Coil Scans Operator: YL Comment: Data for tuning; round 5 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 0.911E-06 12.149E-06 7.20000 7.19995 4417365 7.19985 4432697 7.19990 4417366 7.19970 4432700 I1Y_VS_X 0.000E-03 0.782E-06 10.420E-06 7.20000 7.19980 4417368 7.19915 4432711 7.19980 4417368 7.19910 4432712 I1Y_VS_X 0.000E-03 1.058E-06 14.100E-06 7.20000 7.19975 4417369 7.19880 4432718 7.19970 4417370 7.19880 4432718 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_X 0.000E-03 0.821E-06 10.943E-06 7.20000 7.19970 4417370 7.19865 4432721 7.19965 4417371 7.19865 4432721 I1X_VS_X 0.000E-03 0.980E-06 13.058E-06 7.20000 7.19965 4417371 7.19855 4432723 7.19960 4417372 7.19855 4432723