SLAC Magnetic Measurements Date: 11-29-2018 Time: 13:23:22 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_017 DATASET Number: 1 Tuning Stage: Tuning Run Number: 28 Measurement Type: Long Coil Scans Operator: YL Comment: tuning; round 4 Nom Gap Position X I1X I2X I1Y I2Y --------------------------------------------------------------------------- 9.00000 0.000E-03 0.000E-06 107.808E-06 0.000E-06 135.266E-06 9.00000 0.000E-03 0.000E-06 95.883E-06 0.000E-06 139.741E-06 9.00000 0.000E-03 0.000E-06 99.881E-06 0.000E-06 138.609E-06 9.00000 0.000E-03 0.000E-06 14.213E-06 0.000E-06 125.574E-06 9.00000 0.000E-03 0.000E-06 13.679E-06 0.000E-06 135.272E-06 9.00000 0.000E-03 0.000E-06 14.443E-06 0.000E-06 125.205E-06 9.00000 0.000E-03 0.000E-06 -58.200E-06 0.000E-06 81.180E-06 9.00000 0.000E-03 0.000E-06 -66.040E-06 0.000E-06 84.530E-06 9.00000 0.000E-03 0.000E-06 -67.269E-06 0.000E-06 77.096E-06