SLAC Magnetic Measurements Date: 11-29-2018 Time: 13:09:46 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_017 DATASET Number: 1 Tuning Stage: Tuning Run Number: 26 Measurement Type: Long Coil Scans Operator: YL Comment: tuning; round 4 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_X -2.000E-03 3.149E-06 151.453E-06 9.00000 9.00005 4381363 9.00010 4396692 9.00005 4381363 9.00015 4396691 I2X_VS_X -2.000E-03 2.847E-06 136.956E-06 9.00000 9.00005 4381363 9.00035 4396687 9.00005 4381363 9.00040 4396686