SLAC Magnetic Measurements Date: 10-09-2018 Time: 10:38:35 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_015 DATASET Number: 1 Tuning Stage: Tuning Run Number: 7 Measurement Type: Long Coil Scans Operator: YL Comment: tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_X 0.000E-03 -3.728E-06 -179.307E-06 10.00000 10.00010 4377850 10.00000 4354082 10.00010 4377850 10.00005 4354081 I2X_VS_X 0.000E-03 -3.496E-06 -168.145E-06 10.00000 10.00010 4377850 10.00000 4354082 10.00010 4377850 10.00000 4354082 I2X_VS_X 0.000E-03 -3.543E-06 -170.395E-06 10.00000 10.00015 4377849 10.00000 4354082 10.00010 4377850 10.00000 4354082