SLAC Magnetic Measurements Date: 10-09-2018 Time: 10:30:27 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_015 DATASET Number: 1 Tuning Stage: Tuning Run Number: 5 Measurement Type: Long Coil Scans Operator: YL Comment: data for tuning; round 2 Nom Gap Position X I1X I2X I1Y I2Y --------------------------------------------------------------------------- 7.20000 -2.000E-03 -74.631E-06 0.000E-06 -245.520E-06 0.000E-06 7.20000 -2.000E-03 -74.977E-06 0.000E-06 -263.159E-06 0.000E-06 7.20000 -2.000E-03 -74.111E-06 0.000E-06 -263.986E-06 0.000E-06 7.50000 -2.000E-03 -75.882E-06 0.000E-06 -352.176E-06 0.000E-06 7.50000 -2.000E-03 -76.495E-06 0.000E-06 -356.419E-06 0.000E-06 7.50000 -2.000E-03 -78.098E-06 0.000E-06 -352.555E-06 0.000E-06 10.00000 -2.000E-03 -26.550E-06 0.000E-06 -239.992E-06 0.000E-06 10.00000 -2.000E-03 -27.070E-06 0.000E-06 -242.154E-06 0.000E-06 10.00000 -2.000E-03 -27.242E-06 0.000E-06 -241.482E-06 0.000E-06 13.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 13.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 13.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 16.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 16.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 16.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 22.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 22.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06 22.00000 0.000E-03 0.000E-06 0.000E-06 0.000E-06 0.000E-06