SLAC Magnetic Measurements Date: 02-14-2018 Time: 14:32:32 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_005 DATASET Number: 1 Tuning Stage: Tuning Run Number: 29 Measurement Type: Long Coil Scans Operator: YL Comment: ends tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_X 0.000E-03 -12.628E-06 -607.380E-06 7.20000 7.19985 4413323 7.19990 4418664 7.19970 4413326 7.19975 4418667 I2Y_VS_X 0.000E-03 -12.740E-06 -612.744E-06 7.20000 7.19940 4413332 7.19950 4418672 7.19940 4413332 7.19945 4418673