SLAC Magnetic Measurements Date: 11-30-2017 Time: 08:33:41 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_004 DATASET Number: 1 Tuning Stage: Tuning Run Number: 65 Measurement Type: Long Coil Scans Operator: YL Comment: check Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_X 0.000E-03 1.856E-06 89.248E-06 10.00000 9.99970 4362502 9.99950 4370382 9.99965 4362503 9.99950 4370382