SLAC Magnetic Measurements Date: 04-15-2019 Time: 12:35:44 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_002 DATASET Number: 1 Tuning Stage: Tuning Run Number: 29 Measurement Type: Long Coil Scans Operator: YL Comment: Check Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 1.425E-06 18.992E-06 9.00000 9.00000 4378054 8.99985 4378197 9.00000 4378054 8.99985 4378197 I1Y_VS_X 0.000E-03 1.784E-06 23.782E-06 9.00000 9.00000 4378054 8.99980 4378198 9.00000 4378054 8.99980 4378198 I1Y_VS_X 0.000E-03 1.760E-06 23.457E-06 9.00000 8.99995 4378055 8.99975 4378199 8.99995 4378055 8.99970 4378200