SLAC Magnetic Measurements Date: 04-12-2019 Time: 10:44:04 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_002 DATASET Number: 1 Tuning Stage: Tuning Run Number: 21 Measurement Type: Long Coil Scans Operator: YL Comment: tuning; round 3 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_X -0.000E-03 0.889E-06 11.847E-06 10.00000 9.99955 4358083 9.99980 4358198 9.99940 4358086 9.99975 4358199 I1X_VS_X -0.000E-03 0.887E-06 11.820E-06 10.00000 9.99900 4358094 9.99965 4358201 9.99900 4358094 9.99965 4358201 I1X_VS_X -0.000E-03 0.858E-06 11.434E-06 10.00000 9.99875 4358099 9.99960 4358202 9.99870 4358100 9.99955 4358203