SLAC Magnetic Measurements Date: 04-12-2019 Time: 08:57:51 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_002 DATASET Number: 1 Tuning Stage: Tuning Run Number: 16 Measurement Type: Long Coil Scans Operator: YL Comment: tuning; round 3 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_X 0.000E-03 1.434E-06 68.956E-06 7.20000 7.19985 4414077 7.19990 4414196 7.19975 4414079 7.19985 4414197 I2Y_VS_X 0.000E-03 1.447E-06 69.612E-06 7.20000 7.19935 4414087 7.19965 4414201 7.19935 4414087 7.19960 4414202 I2Y_VS_X 0.000E-03 1.576E-06 75.809E-06 7.20000 7.19915 4414091 7.19950 4414204 7.19910 4414092 7.19945 4414205 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_X 0.000E-03 2.612E-06 125.631E-06 7.50000 7.50000 4408074 7.50000 4408194 7.50005 4408073 7.50005 4408193 I2Y_VS_X 0.000E-03 2.601E-06 125.085E-06 7.50000 7.50015 4408071 7.50025 4408189 7.50015 4408071 7.50025 4408189 I2Y_VS_X 0.000E-03 2.714E-06 130.538E-06 7.50000 7.50020 4408070 7.50035 4408187 7.50015 4408071 7.50040 4408186 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_X 0.000E-03 1.942E-06 93.427E-06 8.00000 8.00015 4398071 8.00005 4398193 8.00030 4398068 8.00010 4398192