SLAC Magnetic Measurements Date: 08-02-2017 Time: 11:47:08 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXR_001 DATASET Number: 1 Tuning Stage: Tuning Run Number: 37 Measurement Type: Long Coil Scans Operator: YL Comment: US end tuning; rotor on pole #8 set to180 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_X 0.000E-03 9.172E-06 441.154E-06 7.20000 7.20000 4430900 7.20000 4422600 7.20000 4430900 7.20000 4422600 I2Y_VS_X 0.000E-03 9.055E-06 435.535E-06 7.20000 7.20000 4430900 7.20000 4422600 7.20000 4430900 7.20000 4422600 I2Y_VS_X 0.000E-03 8.924E-06 429.235E-06 7.20000 7.20000 4430900 7.20000 4422600 7.19995 4430901 7.20000 4422600