SLAC Magnetic Measurements Date: 08-10-2020 Time: 15:30:02 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_032 DATASET Number: 1 Tuning Stage: Tuning Run Number: 7 Measurement Type: Long Coil Scans Operator: YL Comment: tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_Y 0.000E-03 -0.079E-06 1.432E-06 7.30000 7.29995 3.65340 7.29975 3.65530 7.29990 3.65340 7.29975 3.65520 I1Y_VS_Y 0.000E-03 -0.107E-06 1.948E-06 7.30000 7.29965 3.65330 7.29965 3.65520 7.29965 3.65330 7.29965 3.65520 I1Y_VS_Y 0.000E-03 -0.087E-06 1.580E-06 7.30000 7.29955 3.65320 7.29960 3.65520 7.29950 3.65320 7.29965 3.65520 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_Y 0.000E-03 -0.060E-06 1.092E-06 8.00000 8.00020 4.00310 8.00010 4.00190 8.00020 4.00300 8.00010 4.00180