SLAC Magnetic Measurements Date: 11-15-2019 Time: 08:58:33 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_030 DATASET Number: 1 Tuning Stage: Tuning Run Number: 1 Measurement Type: PM Center Operator: YL Comment: fiducialization ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- URM 1 0.000778 -0.033313 0.516905 UPM 2 0.000393 -0.027347 1.363201 DPM 3 0.000062 -0.027032 5.048083 DRM 4 -0.000002 -0.032853 5.836765 UPM 2 0.000393 -0.027346 1.363197 DPM 3 0.000059 -0.027015 5.048051 DRM 4 -0.000002 -0.032851 5.836764 URM 1 0.000779 -0.033316 0.516904