SLAC Magnetic Measurements Date: 10-16-2019 Time: 15:43:13 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_028 DATASET Number: 1 Tuning Stage: Tuning Run Number: 12 Measurement Type: Long Coil Scans Operator: YL Comment: Tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_Y -1.000E-03 0.383E-06 28.214E-06 7.20000 7.20000 3.60030 7.19975 3.59950 7.20000 3.60030 7.19975 3.59950 I2X_VS_Y -1.000E-03 0.436E-06 32.169E-06 7.20000 7.19990 3.60030 7.19970 3.59940 7.19995 3.60020 7.19965 3.59940 I2X_VS_Y -1.000E-03 0.504E-06 37.173E-06 7.20000 7.19985 3.60030 7.19965 3.59940 7.19990 3.60030 7.19965 3.59940 I2X_VS_Y 0.000E-03 0.156E-06 11.487E-06 7.20000 7.19980 3.60030 7.19960 3.59940 7.19985 3.60030 7.19960 3.59940 I2X_VS_Y 0.000E-03 0.176E-06 13.004E-06 7.20000 7.19980 3.60030 7.19960 3.59940 7.19980 3.60020 7.19955 3.59940 I2X_VS_Y 0.000E-03 0.000E-06 0.000E-06 7.20000 7.19980 3.60030 7.19960 3.59940 7.19980 3.60030 7.19960 3.59940 I2X_VS_Y 1.000E-03 -0.189E-06 -13.964E-06 7.20000 7.19975 3.60020 7.19955 3.59940 7.19975 3.60020 7.19955 3.59940 I2X_VS_Y 1.000E-03 -0.380E-06 -28.054E-06 7.20000 7.19970 3.60030 7.19955 3.59940 7.19970 3.60020 7.19955 3.59940