SLAC Magnetic Measurements Date: 10-16-2019 Time: 15:12:17 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_028 DATASET Number: 1 Tuning Stage: Tuning Run Number: 10 Measurement Type: Long Coil Scans Operator: YL Comment: Tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_Y -1.000E-03 1.528E-06 27.765E-06 7.30000 7.30015 3.65100 7.29975 3.64980 7.30010 3.65110 7.29980 3.64980 I1X_VS_Y -1.000E-03 1.517E-06 27.576E-06 7.30000 7.30015 3.65100 7.29980 3.64980 7.30010 3.65100 7.29975 3.64980 I1X_VS_Y -1.000E-03 1.560E-06 28.354E-06 7.30000 7.30015 3.65100 7.29975 3.64990 7.30015 3.65100 7.29975 3.64980 I1X_VS_Y 0.000E-03 0.506E-06 9.193E-06 7.30000 7.30010 3.65100 7.29980 3.64980 7.30010 3.65100 7.29975 3.64980 I1X_VS_Y 0.000E-03 0.507E-06 9.218E-06 7.30000 7.30010 3.65100 7.29980 3.64990 7.30010 3.65100 7.29980 3.64980 I1X_VS_Y 0.000E-03 0.509E-06 9.251E-06 7.30000 7.30005 3.65110 7.29980 3.64980 7.30005 3.65100 7.29980 3.64980 I1X_VS_Y 1.000E-03 -0.276E-06 -5.021E-06 7.30000 7.30005 3.65100 7.29975 3.64980 7.30005 3.65100 7.29975 3.64990