SLAC Magnetic Measurements Date: 06-14-2019 Time: 08:26:08 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_022 DATASET Number: 1 Tuning Stage: Tuning Run Number: 3 Measurement Type: PM Center Operator: VV Comment: fiducialization ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- URM 1 0.000837 -0.033311 0.516085 UPM 2 0.000313 -0.025850 1.359074 DPM 3 0.000150 -0.025464 5.043435 DRM 4 0.000086 -0.032882 5.835496 UPM 2 0.000313 -0.025846 1.359070 DPM 3 0.000151 -0.025464 5.043447 DRM 4 0.000085 -0.032872 5.835489 URM 1 0.000838 -0.033343 0.516067