SLAC Magnetic Measurements Date: 06-12-2019 Time: 13:10:51 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_022 DATASET Number: 1 Tuning Stage: Tuning Run Number: 15 Measurement Type: Long Coil Scans Operator: VV Comment: check before final Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_Y -1.000E-03 1.232E-06 27.367E-06 17.00000 17.00000 8.49300 16.99990 8.49330 17.00000 8.49300 16.99990 8.49320 I1Y_VS_Y -1.000E-03 1.327E-06 29.479E-06 17.00000 16.99995 8.49300 16.99990 8.49330 16.99995 8.49300 16.99990 8.49320 I1Y_VS_Y -1.000E-03 1.900E-06 42.205E-06 17.00000 16.99995 8.49300 16.99990 8.49330 16.99995 8.49300 16.99990 8.49340 I1Y_VS_Y 0.000E-03 0.943E-06 20.951E-06 17.00000 17.00000 8.49300 16.99990 8.49330 16.99995 8.49300 16.99990 8.49320 I1Y_VS_Y 0.000E-03 1.439E-06 31.959E-06 17.00000 16.99990 8.49290 16.99990 8.49330 16.99990 8.49290 16.99990 8.49320 I1Y_VS_Y 0.000E-03 1.126E-06 25.004E-06 17.00000 16.99990 8.49300 16.99990 8.49320 16.99990 8.49300 16.99990 8.49320 I1Y_VS_Y 1.000E-03 1.241E-06 27.570E-06 17.00000 16.99990 8.49300 16.99990 8.49320 16.99990 8.49300 16.99990 8.49330 I1Y_VS_Y 1.000E-03 1.089E-06 24.193E-06 17.00000 16.99995 8.49300 16.99990 8.49320 16.99990 8.49300 16.99990 8.49340