SLAC Magnetic Measurements Date: 06-12-2019 Time: 13:05:21 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_022 DATASET Number: 1 Tuning Stage: Tuning Run Number: 14 Measurement Type: Long Coil Scans Operator: VV Comment: check before final Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X -0.500E-03 1.255E-06 27.877E-06 17.00000 17.00020 8.49310 17.00025 8.49330 17.00015 8.49300 17.00025 8.49320 I1Y_VS_X -0.500E-03 1.086E-06 24.116E-06 17.00000 17.00015 8.49300 17.00010 8.49330 17.00010 8.49300 17.00015 8.49320 I1Y_VS_X -0.500E-03 1.359E-06 30.184E-06 17.00000 17.00010 8.49310 17.00005 8.49330 17.00010 8.49300 17.00005 8.49330 I1Y_VS_X 0.000E-03 1.441E-06 32.021E-06 17.00000 17.00005 8.49310 17.00005 8.49330 17.00005 8.49300 17.00005 8.49340 I1Y_VS_X 0.000E-03 1.201E-06 26.686E-06 17.00000 17.00000 8.49300 17.00005 8.49340 17.00005 8.49300 17.00005 8.49330 I1Y_VS_X 0.000E-03 1.352E-06 30.041E-06 17.00000 17.00005 8.49300 17.00000 8.49330 17.00010 8.49300 16.99995 8.49330 I1Y_VS_X 0.500E-03 1.185E-06 26.314E-06 17.00000 17.00000 8.49300 17.00000 8.49330 17.00005 8.49300 17.00000 8.49330 I1Y_VS_X 0.500E-03 0.899E-06 19.961E-06 17.00000 17.00000 8.49300 16.99995 8.49330 17.00000 8.49300 16.99995 8.49330