SLAC Magnetic Measurements Date: 06-12-2019 Time: 12:59:15 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_022 DATASET Number: 1 Tuning Stage: Tuning Run Number: 13 Measurement Type: Long Coil Scans Operator: VV Comment: check before final Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_X -0.500E-03 -1.192E-06 95.727E-06 20.00000 20.00000 9.99120 19.99980 9.99170 20.00000 9.99120 19.99980 9.99170 I2X_VS_X -0.500E-03 -1.124E-06 90.298E-06 20.00000 20.00000 9.99120 19.99980 9.99180 20.00000 9.99120 19.99985 9.99180 I2X_VS_X -0.500E-03 -1.229E-06 98.722E-06 20.00000 20.00005 9.99120 19.99980 9.99170 20.00000 9.99120 19.99980 9.99180 I2X_VS_X 0.000E-03 -1.374E-06 110.295E-06 20.00000 20.00000 9.99120 19.99980 9.99170 20.00005 9.99120 19.99980 9.99170 I2X_VS_X 0.000E-03 -1.420E-06 114.028E-06 20.00000 20.00000 9.99120 19.99980 9.99160 20.00005 9.99120 19.99980 9.99160 I2X_VS_X 0.000E-03 -1.512E-06 121.427E-06 20.00000 20.00000 9.99120 19.99980 9.99160 20.00005 9.99120 19.99980 9.99160 I2X_VS_X 0.500E-03 -1.510E-06 121.255E-06 20.00000 20.00005 9.99120 19.99980 9.99160 20.00005 9.99120 19.99980 9.99160 I2X_VS_X 0.500E-03 -1.164E-06 93.460E-06 20.00000 20.00005 9.99120 19.99980 9.99170 20.00005 9.99120 19.99980 9.99160