SLAC Magnetic Measurements Date: 06-12-2019 Time: 12:53:41 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_022 DATASET Number: 1 Tuning Stage: Tuning Run Number: 12 Measurement Type: Long Coil Scans Operator: VV Comment: check before final Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_Y -1.000E-03 -1.234E-06 99.130E-06 20.00000 20.00000 9.99110 19.99985 9.99160 20.00005 9.99110 19.99985 9.99160 I2X_VS_Y -1.000E-03 -1.329E-06 106.682E-06 20.00000 20.00000 9.99110 19.99985 9.99160 20.00005 9.99110 19.99985 9.99160 I2X_VS_Y -1.000E-03 -1.314E-06 105.477E-06 20.00000 20.00005 9.99120 19.99985 9.99170 20.00005 9.99110 19.99985 9.99160 I2X_VS_Y 0.000E-03 -1.276E-06 102.439E-06 20.00000 20.00000 9.99110 19.99985 9.99170 20.00005 9.99110 19.99985 9.99160 I2X_VS_Y 0.000E-03 -1.354E-06 108.762E-06 20.00000 20.00000 9.99120 19.99985 9.99180 20.00000 9.99120 19.99985 9.99170 I2X_VS_Y 0.000E-03 -0.978E-06 78.501E-06 20.00000 20.00000 9.99120 19.99980 9.99170 20.00000 9.99120 19.99985 9.99170 I2X_VS_Y 1.000E-03 -1.505E-06 120.875E-06 20.00000 20.00000 9.99120 19.99980 9.99170 20.00000 9.99120 19.99980 9.99170 I2X_VS_Y 1.000E-03 -1.199E-06 96.253E-06 20.00000 20.00000 9.99120 19.99980 9.99170 20.00000 9.99120 19.99980 9.99170