SLAC Magnetic Measurements Date: 06-10-2019 Time: 13:19:43 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_022 DATASET Number: 1 Tuning Stage: Tuning Run Number: 2 Measurement Type: Long Coil Scans Operator: VV Comment: slugs between poles 43, 44; M3 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_Y 0.000E-03 -0.432E-06 9.595E-06 9.00000 8.99990 4.50330 8.99945 4.50260 8.99990 4.50330 8.99945 4.50260 I1X_VS_Y 0.000E-03 -0.386E-06 8.573E-06 9.00000 8.99980 4.50330 8.99935 4.50250 8.99980 4.50330 8.99935 4.50260 I1X_VS_Y 0.000E-03 -0.380E-06 8.433E-06 9.00000 8.99975 4.50320 8.99935 4.50250 8.99975 4.50330 8.99930 4.50260