SLAC Magnetic Measurements Date: 07-26-2019 Time: 14:27:46 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_021 DATASET Number: 1 Tuning Stage: Tuning Run Number: 16 Measurement Type: Long Coil Scans Operator: VV Comment: New coil, Bx= -126 G-cm Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_Y 0.000E-03 12.062E-06 -160.798E-06 7.20000 7.20020 3.60390 7.19985 3.60550 7.20020 3.60390 7.19990 3.60540 I1X_VS_Y 0.000E-03 12.061E-06 -160.770E-06 7.20000 7.20020 3.60400 7.19995 3.60550 7.20020 3.60400 7.19995 3.60540 I1X_VS_Y 0.000E-03 12.098E-06 -161.258E-06 7.20000 7.20025 3.60400 7.19995 3.60540 7.20020 3.60390 7.19990 3.60530