SLAC Magnetic Measurements Date: 10-26-2020 Time: 16:12:41 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_015 DATASET Number: 1 Tuning Stage: Tuning Run Number: 25 Measurement Type: Long Coil Scans Operator: YL Comment: tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_Y 0.000E-03 0.068E-06 -1.230E-06 7.25000 8.00060 4.00360 8.00085 4.00250 8.00060 4.00360 8.00085 4.00250